From a90ad6e16c248352e854c66ad8716b8cae293128 Mon Sep 17 00:00:00 2001 From: Dion Moult Date: Thu, 23 Apr 2020 18:16:04 +1000 Subject: [PATCH] Only bundle Uniclass and Omniclass. Other systems can be downloaded online. --- .../schema/classifications/Omniclass_OCCS.ifc | 17008 +++++------ .../classifications/Uniclass2015_Jan2020.ifc | 24934 ++++++++-------- src/ifcblenderexport/getIfcClassification.py | 63 - 3 files changed, 20973 insertions(+), 21032 deletions(-) delete mode 100644 src/ifcblenderexport/getIfcClassification.py diff --git a/src/ifcblenderexport/blenderbim/bim/schema/classifications/Omniclass_OCCS.ifc b/src/ifcblenderexport/blenderbim/bim/schema/classifications/Omniclass_OCCS.ifc index aa25c64ff8..10fe155b86 100644 --- a/src/ifcblenderexport/blenderbim/bim/schema/classifications/Omniclass_OCCS.ifc +++ b/src/ifcblenderexport/blenderbim/bim/schema/classifications/Omniclass_OCCS.ifc @@ -1,8511 +1,8513 @@ ISO-10303-21; HEADER; FILE_DESCRIPTION(('ViewDefinition [CoordinationView]'),'2;1'); -FILE_NAME('','2020-04-23T11:00:36',(),(),'IfcOpenShell 0.6.0b0','IfcOpenShell 0.6.0b0',''); +FILE_NAME('','2020-04-23T18:09:33',(),(),'IfcOpenShell 0.6.0b0','IfcOpenShell 0.6.0b0',''); FILE_SCHEMA(('IFC4')); ENDSEC; DATA; -#1=IFCCLASSIFICATION('OmniClass','(OCCS)','2017-03-28','OmniClass','The OmniClass Construction Classification System (known as OmniClass\X2\2122\X0\ or OCCS) is a classification system for the construction industry. OmniClass is useful for many applications, from organizing library materials, product literature, and project information, to providing a classification structure for electronic databases.','http://www.omniclass.org/',('-',' ')); -#2=IFCCLASSIFICATIONREFERENCE($,'Table 13 - Space by Function',$,#1,'Assigns a functional classification to ARCHICAD Zones based on this OmniClass (edition 2012) specification.\X2\000A000A\X0\For example: use this rule to comply with ''Concept Design BIM 2010'' MVD (GSA) and ''FM Handover'' (COBie) MVDs, which require such classification for IfcSpace entities.\X2\000A000A\X0\''Apply'' creates a Classification Reference for selected IfcSpace (or IfcSpaceType) entities, using OmniClass-required attributes derived from the item that you choose in the following list.\X2\000A00090009\X0\',$); -#3=IFCCLASSIFICATIONREFERENCE($,'13-11 00 00','Space Planning Types',#2,$,$); -#4=IFCCLASSIFICATIONREFERENCE($,'13-11 11 00','Planned Work Space',#3,$,$); -#5=IFCCLASSIFICATIONREFERENCE($,'13-11 13 00','Planned Building Service Space',#3,$,$); -#6=IFCCLASSIFICATIONREFERENCE($,'13-11 15 00','Planned Amenity/Support Space',#3,$,$); -#7=IFCCLASSIFICATIONREFERENCE($,'13-11 17 00','Planned Circulation Space',#3,$,$); -#8=IFCCLASSIFICATIONREFERENCE($,'13-11 19 00','Planned Parking Space',#3,$,$); -#9=IFCCLASSIFICATIONREFERENCE($,'13-13 00 00','Void Areas',#2,$,$); -#10=IFCCLASSIFICATIONREFERENCE($,'13-13 11 00','Light Well',#9,$,$); -#11=IFCCLASSIFICATIONREFERENCE($,'13-13 13 00','Air Shaft',#9,$,$); -#12=IFCCLASSIFICATIONREFERENCE($,'13-13 15 00','Occupant Void Area',#9,$,$); -#13=IFCCLASSIFICATIONREFERENCE($,'13-15 00 00','Wall Spaces',#2,$,$); -#14=IFCCLASSIFICATIONREFERENCE($,'13-15 11 00','Exterior Wall Space',#13,$,$); -#15=IFCCLASSIFICATIONREFERENCE($,'13-15 13 00','Interior Wall Space',#13,$,$); -#16=IFCCLASSIFICATIONREFERENCE($,'13-17 00 00','Encroachment Spaces',#2,$,$); -#17=IFCCLASSIFICATIONREFERENCE($,'13-17 11 00','Interior Encroachment',#16,$,$); -#18=IFCCLASSIFICATIONREFERENCE($,'13-17 13 00','Perimeter Encroachment',#16,$,$); -#19=IFCCLASSIFICATIONREFERENCE($,'13-21 00 00','Parking Spaces',#2,$,$); -#20=IFCCLASSIFICATIONREFERENCE($,'13-21 11 00','Exterior Parking Spaces',#19,$,$); -#21=IFCCLASSIFICATIONREFERENCE($,'13-21 11 11','Exterior Parking Circulation',#20,$,$); -#22=IFCCLASSIFICATIONREFERENCE($,'13-21 11 13','Exterior Parking Access Control Point',#20,$,$); -#23=IFCCLASSIFICATIONREFERENCE($,'13-21 11 15','Exterior Parking Stall',#20,$,$); -#24=IFCCLASSIFICATIONREFERENCE($,'13-21 13 00','Interior Parking Spaces',#19,$,$); -#25=IFCCLASSIFICATIONREFERENCE($,'13-21 13 11','Interior Parking Ramp and Circulation',#24,$,$); -#26=IFCCLASSIFICATIONREFERENCE($,'13-21 13 13','Interior Parking Access Control Point',#24,$,$); -#27=IFCCLASSIFICATIONREFERENCE($,'13-21 13 15','Interior Parking Stall',#24,$,$); -#28=IFCCLASSIFICATIONREFERENCE($,'13-21 13 17','Interior Vehicle Service Space',#24,$,$); -#29=IFCCLASSIFICATIONREFERENCE($,'13-23 00 00','Facility Service Spaces',#2,$,$); -#30=IFCCLASSIFICATIONREFERENCE($,'13-23 11 00','Vertical Penetration',#29,$,$); -#31=IFCCLASSIFICATIONREFERENCE($,'13-23 11 11','Mechanical Circulation',#30,$,$); -#32=IFCCLASSIFICATIONREFERENCE($,'13-23 11 11 11','Elevator Shaft',#31,$,$); -#33=IFCCLASSIFICATIONREFERENCE($,'13-23 11 11 13','Elevator Pit',#31,$,$); -#34=IFCCLASSIFICATIONREFERENCE($,'13-23 11 11 15','Elevator Cab',#31,$,$); -#35=IFCCLASSIFICATIONREFERENCE($,'13-23 11 11 17','Elevator Machine Room',#31,$,$); -#36=IFCCLASSIFICATIONREFERENCE($,'13-23 11 11 19','Dumbwaiter',#31,$,$); -#37=IFCCLASSIFICATIONREFERENCE($,'13-23 11 11 21','Escalator',#31,$,$); -#38=IFCCLASSIFICATIONREFERENCE($,'13-23 11 11 23','Freight Elevator',#31,$,$); -#39=IFCCLASSIFICATIONREFERENCE($,'13-23 11 13','Stairway',#30,$,$); -#40=IFCCLASSIFICATIONREFERENCE($,'13-23 11 13 11','Egress Stairway',#39,$,$); -#41=IFCCLASSIFICATIONREFERENCE($,'13-23 11 13 13','Tenant Stairway',#39,$,$); -#42=IFCCLASSIFICATIONREFERENCE($,'13-23 11 15','Monumental Stair',#30,$,$); -#43=IFCCLASSIFICATIONREFERENCE($,'13-23 11 17','Ramp',#30,$,$); -#44=IFCCLASSIFICATIONREFERENCE($,'13-23 11 19','Chimney',#30,$,$); -#45=IFCCLASSIFICATIONREFERENCE($,'13-23 11 21','Chute',#30,$,$); -#46=IFCCLASSIFICATIONREFERENCE($,'13-23 11 23','Service Riser Space',#30,$,$); -#47=IFCCLASSIFICATIONREFERENCE($,'13-23 11 23 11','Power Distribution Riser',#46,$,$); -#48=IFCCLASSIFICATIONREFERENCE($,'13-23 11 23 13','Information Signal Distribution Riser',#46,$,$); -#49=IFCCLASSIFICATIONREFERENCE($,'13-23 11 23 15','Gas Distribution Riser',#46,$,$); -#50=IFCCLASSIFICATIONREFERENCE($,'13-23 11 23 17','Liquid Distribution Riser',#46,$,$); -#51=IFCCLASSIFICATIONREFERENCE($,'13-23 12 00','Horizontal Infrastructure/Service Space, Non-Occupied',#29,$,$); -#52=IFCCLASSIFICATIONREFERENCE($,'13-23 12 11','Power Distribution Network',#51,$,$); -#53=IFCCLASSIFICATIONREFERENCE($,'13-23 12 13','Information Signal Network',#51,$,$); -#54=IFCCLASSIFICATIONREFERENCE($,'13-23 12 15','Gas Distribution Network',#51,$,$); -#55=IFCCLASSIFICATIONREFERENCE($,'13-23 12 17','Liquid Distribution Spaces',#51,$,$); -#56=IFCCLASSIFICATIONREFERENCE($,'13-23 13 00','Control Room',#29,$,$); -#57=IFCCLASSIFICATIONREFERENCE($,'13-23 13 11','Fire Command Center',#56,$,$); -#58=IFCCLASSIFICATIONREFERENCE($,'13-23 13 13','Guard Stations',#56,$,$); -#59=IFCCLASSIFICATIONREFERENCE($,'13-23 15 00','Loading Dock',#29,$,$); -#60=IFCCLASSIFICATIONREFERENCE($,'13-23 17 00','Restroom',#29,$,$); -#61=IFCCLASSIFICATIONREFERENCE($,'13-23 17 11','Men''s Restroom',#60,$,$); -#62=IFCCLASSIFICATIONREFERENCE($,'13-23 17 13','Women''s Restroom',#60,$,$); -#63=IFCCLASSIFICATIONREFERENCE($,'13-23 17 15','Unisex Restroom',#60,$,$); -#64=IFCCLASSIFICATIONREFERENCE($,'13-23 19 00','Utility Equipment Room',#29,$,$); -#65=IFCCLASSIFICATIONREFERENCE($,'13-23 19 11','Refrigerant Machinery Room',#64,$,$); -#66=IFCCLASSIFICATIONREFERENCE($,'13-23 19 13','Furnace Room',#64,$,$); -#67=IFCCLASSIFICATIONREFERENCE($,'13-23 19 15','Incinerator Room',#64,$,$); -#68=IFCCLASSIFICATIONREFERENCE($,'13-23 19 17','Fuel Room',#64,$,$); -#69=IFCCLASSIFICATIONREFERENCE($,'13-23 19 19','Gas Room',#64,$,$); -#70=IFCCLASSIFICATIONREFERENCE($,'13-23 19 21','Liquid Storage Room',#64,$,$); -#71=IFCCLASSIFICATIONREFERENCE($,'13-23 19 23','Liquid Use, Dispensing and Mixing Room',#64,$,$); -#72=IFCCLASSIFICATIONREFERENCE($,'13-23 19 25','Hydrogen Cutoff Room',#64,$,$); -#73=IFCCLASSIFICATIONREFERENCE($,'13-23 19 27','Electrical Room',#64,$,$); -#74=IFCCLASSIFICATIONREFERENCE($,'13-23 19 29','Switch Room',#64,$,$); -#75=IFCCLASSIFICATIONREFERENCE($,'13-23 19 31','Telecommunications Room',#64,$,$); -#76=IFCCLASSIFICATIONREFERENCE($,'13-23 19 33','Transformer Vault',#64,$,$); -#77=IFCCLASSIFICATIONREFERENCE($,'13-23 21 00','Waste and Recycling Spaces',#29,$,$); -#78=IFCCLASSIFICATIONREFERENCE($,'13-23 21 11','Hazardous Waste Storage',#77,$,$); -#79=IFCCLASSIFICATIONREFERENCE($,'13-23 23 00','Building Service Support Spaces',#29,$,$); -#80=IFCCLASSIFICATIONREFERENCE($,'13-23 23 11','Building Manager Office',#79,$,$); -#81=IFCCLASSIFICATIONREFERENCE($,'13-23 23 13','Custodial Space',#79,$,$); -#82=IFCCLASSIFICATIONREFERENCE($,'13-23 23 15','Shop Area',#79,$,$); -#83=IFCCLASSIFICATIONREFERENCE($,'13-23 23 17','Access Chamber',#79,$,$); -#84=IFCCLASSIFICATIONREFERENCE($,'13-23 23 19','Areaway',#79,$,$); -#85=IFCCLASSIFICATIONREFERENCE($,'13-23 23 21','Service Space',#79,$,$); -#86=IFCCLASSIFICATIONREFERENCE($,'13-23 23 23','Furred Space',#79,$,$); -#87=IFCCLASSIFICATIONREFERENCE($,'13-23 23 25','Crawl Space',#79,$,$); -#88=IFCCLASSIFICATIONREFERENCE($,'13-23 23 27','Attic Space',#79,$,$); -#89=IFCCLASSIFICATIONREFERENCE($,'13-23 23 29','Plenum',#79,$,$); -#90=IFCCLASSIFICATIONREFERENCE($,'13-23 25 00','Equipment Platform',#29,$,$); -#91=IFCCLASSIFICATIONREFERENCE($,'13-23 27 00','Interstitial Space',#29,$,$); -#92=IFCCLASSIFICATIONREFERENCE($,'13-23 29 00','Unimproved Shell',#29,$,$); -#93=IFCCLASSIFICATIONREFERENCE($,'13-23 31 00','Alteration or Conversion Space',#29,$,$); -#94=IFCCLASSIFICATIONREFERENCE($,'13-25 00 00','Circulation Spaces',#2,$,$); -#95=IFCCLASSIFICATIONREFERENCE($,'13-25 11 00','Primary Circulation Spaces',#94,$,$); -#96=IFCCLASSIFICATIONREFERENCE($,'13-25 11 11','Corridor',#95,$,$); -#97=IFCCLASSIFICATIONREFERENCE($,'13-25 11 13','Aisle',#95,$,$); -#98=IFCCLASSIFICATIONREFERENCE($,'13-25 11 15','Mall',#95,$,$); -#99=IFCCLASSIFICATIONREFERENCE($,'13-25 11 17','Concourse',#95,$,$); -#100=IFCCLASSIFICATIONREFERENCE($,'13-25 11 19','Breezeway',#95,$,$); -#101=IFCCLASSIFICATIONREFERENCE($,'13-25 11 21','Moving Walkway',#95,$,$); -#102=IFCCLASSIFICATIONREFERENCE($,'13-25 13 00','Transitional Circulation Spaces',#94,$,$); -#103=IFCCLASSIFICATIONREFERENCE($,'13-25 13 11','Entry Vestibule',#102,$,$); -#104=IFCCLASSIFICATIONREFERENCE($,'13-25 13 13','Entry Lobby',#102,$,$); -#105=IFCCLASSIFICATIONREFERENCE($,'13-25 13 15','Box Lobby',#102,$,$); -#106=IFCCLASSIFICATIONREFERENCE($,'13-25 13 17','Vestibule',#102,$,$); -#107=IFCCLASSIFICATIONREFERENCE($,'13-25 13 19','Elevator Lobby',#102,$,$); -#108=IFCCLASSIFICATIONREFERENCE($,'13-25 13 21','Freight Elevator Vestibule',#102,$,$); -#109=IFCCLASSIFICATIONREFERENCE($,'13-25 13 23','Landing',#102,$,$); -#110=IFCCLASSIFICATIONREFERENCE($,'13-25 13 25','Anteroom',#102,$,$); -#111=IFCCLASSIFICATIONREFERENCE($,'13-25 13 27','Air Lock',#102,$,$); -#112=IFCCLASSIFICATIONREFERENCE($,'13-25 13 29','Sally Port',#102,$,$); -#113=IFCCLASSIFICATIONREFERENCE($,'13-25 13 31','Jet Way',#102,$,$); -#114=IFCCLASSIFICATIONREFERENCE($,'13-25 15 00','Connector',#94,$,$); -#115=IFCCLASSIFICATIONREFERENCE($,'13-25 17 00','External Circulation Spaces',#94,$,$); -#116=IFCCLASSIFICATIONREFERENCE($,'13-25 19 00','Secondary Circulation Spaces',#94,$,$); -#117=IFCCLASSIFICATIONREFERENCE($,'13-25 19 11','Door Set-Back',#116,$,$); -#118=IFCCLASSIFICATIONREFERENCE($,'13-25 21 00','Restricted Spaces',#94,$,$); -#119=IFCCLASSIFICATIONREFERENCE($,'13-25 23 00','Refuge Spaces',#94,$,$); -#120=IFCCLASSIFICATIONREFERENCE($,'13-31 00 00','Education and Training Spaces',#2,$,$); -#121=IFCCLASSIFICATIONREFERENCE($,'13-31 11 00','Breakout Space',#120,$,$); -#122=IFCCLASSIFICATIONREFERENCE($,'13-31 13 00','Lecture and Classroom Spaces',#120,$,$); -#123=IFCCLASSIFICATIONREFERENCE($,'13-31 13 11','Lecture Classroom',#122,$,$); -#124=IFCCLASSIFICATIONREFERENCE($,'13-31 13 13','Classrooms (age 9 plus)',#122,$,$); -#125=IFCCLASSIFICATIONREFERENCE($,'13-31 13 15','Classrooms (ages 5\X2\2013\X0\8)',#122,$,$); -#126=IFCCLASSIFICATIONREFERENCE($,'13-31 13 17','Lecture Hall (Fixed Seats)',#122,$,$); -#127=IFCCLASSIFICATIONREFERENCE($,'13-31 13 19','Assembly Hall',#122,$,$); -#128=IFCCLASSIFICATIONREFERENCE($,'13-31 13 21','Seminar Room',#122,$,$); -#129=IFCCLASSIFICATIONREFERENCE($,'13-31 15 00','Class Laboratories',#120,$,$); -#130=IFCCLASSIFICATIONREFERENCE($,'13-31 15 11','Open Class Laboratory',#129,$,$); -#131=IFCCLASSIFICATIONREFERENCE($,'13-31 15 11 11','Physics Teaching Laboratory',#130,$,$); -#132=IFCCLASSIFICATIONREFERENCE($,'13-31 15 11 13','Astronomy Teaching Laboratory',#130,$,$); -#133=IFCCLASSIFICATIONREFERENCE($,'13-31 15 13','Research/non-class Class Laboratory',#129,$,$); -#134=IFCCLASSIFICATIONREFERENCE($,'13-31 15 15','Laboratory Service Space',#129,$,$); -#135=IFCCLASSIFICATIONREFERENCE($,'13-31 17 00','Training Spaces',#120,$,$); -#136=IFCCLASSIFICATIONREFERENCE($,'13-31 17 11','Computer Lab',#135,$,$); -#137=IFCCLASSIFICATIONREFERENCE($,'13-31 17 13','Woodshop/Metalshop',#135,$,$); -#138=IFCCLASSIFICATIONREFERENCE($,'13-31 17 15','Training Support Space',#135,$,$); -#139=IFCCLASSIFICATIONREFERENCE($,'13-31 17 17','Religious Education Space',#135,$,$); -#140=IFCCLASSIFICATIONREFERENCE($,'13-31 19 00','Study Spaces',#120,$,$); -#141=IFCCLASSIFICATIONREFERENCE($,'13-31 19 13','Study Room',#140,$,$); -#142=IFCCLASSIFICATIONREFERENCE($,'13-31 19 15','Study Service',#140,$,$); -#143=IFCCLASSIFICATIONREFERENCE($,'13-33 00 00','Recreation Spaces',#2,$,$); -#144=IFCCLASSIFICATIONREFERENCE($,'13-33 11 00','Athletic Recreation Spaces',#143,$,$); -#145=IFCCLASSIFICATIONREFERENCE($,'13-33 11 11','Athletic Spectator Seating',#144,$,$); -#146=IFCCLASSIFICATIONREFERENCE($,'13-33 11 11 11','Bleacher',#145,$,$); -#147=IFCCLASSIFICATIONREFERENCE($,'13-33 11 13','Team Athletic Recreation Spaces',#144,$,$); -#148=IFCCLASSIFICATIONREFERENCE($,'13-33 11 13 11','Baseball Field',#147,$,$); -#149=IFCCLASSIFICATIONREFERENCE($,'13-33 11 13 13','Softball Fields',#147,$,$); -#150=IFCCLASSIFICATIONREFERENCE($,'13-33 11 13 15','Dugouts',#147,$,$); -#151=IFCCLASSIFICATIONREFERENCE($,'13-33 11 13 17','Grass Playing Fields',#147,$,$); -#152=IFCCLASSIFICATIONREFERENCE($,'13-33 11 13 19','Synthetic Fields',#147,$,$); -#153=IFCCLASSIFICATIONREFERENCE($,'13-33 11 13 21','Football Field',#147,$,$); -#154=IFCCLASSIFICATIONREFERENCE($,'13-33 11 13 23','Soccer Field',#147,$,$); -#155=IFCCLASSIFICATIONREFERENCE($,'13-33 11 13 25','Basketball Courts',#147,$,$); -#156=IFCCLASSIFICATIONREFERENCE($,'13-33 11 13 27','Field Light Poles',#147,$,$); -#157=IFCCLASSIFICATIONREFERENCE($,'13-33 11 13 29','Press Box',#147,$,$); -#158=IFCCLASSIFICATIONREFERENCE($,'13-33 11 13 31','Scoreboards',#147,$,$); -#159=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15','Individual Athletic Recreation Spaces',#144,$,$); -#160=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 11','Hard Playing Surfaces',#159,$,$); -#161=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 13','Tennis Courts',#159,$,$); -#162=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 15','Volleyball Court',#159,$,$); -#163=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 17','Golf Course',#159,$,$); -#164=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 19','Driving Range',#159,$,$); -#165=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 21','Golf Course Support Space',#159,$,$); -#166=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 23','Skating Rink',#159,$,$); -#167=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 25','Boxing Ring',#159,$,$); -#168=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 27','Wrestling Mat',#159,$,$); -#169=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 29','Diving Board',#159,$,$); -#170=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 31','Bowling Lane',#159,$,$); -#171=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 33','Dart Throwing Area',#159,$,$); -#172=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 35','Circuit Training Course Area',#159,$,$); -#173=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 37','Running Tracks',#159,$,$); -#174=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 39','Ski Lift Space',#159,$,$); -#175=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 41','Exercise Space',#159,$,$); -#176=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 43','Workout Station',#159,$,$); -#177=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 45','Aerobic Studio',#159,$,$); -#178=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 47','Climbing Wall',#159,$,$); -#179=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 49','Ropes Course Elements',#159,$,$); -#180=IFCCLASSIFICATIONREFERENCE($,'13-33 13 00','Swimming Pools',#143,$,$); -#181=IFCCLASSIFICATIONREFERENCE($,'13-33 13 11','Outdoor Swimming Pool',#180,$,$); -#182=IFCCLASSIFICATIONREFERENCE($,'13-33 13 13','Indoor Swimming Pool',#180,$,$); -#183=IFCCLASSIFICATIONREFERENCE($,'13-33 13 13 11','Diving Tank',#182,$,$); -#184=IFCCLASSIFICATIONREFERENCE($,'13-33 15 00','Non-Athletic Recreation Spaces',#143,$,$); -#185=IFCCLASSIFICATIONREFERENCE($,'13-33 15 11','Park',#184,$,$); -#186=IFCCLASSIFICATIONREFERENCE($,'13-33 15 13','Pleasure Garden',#184,$,$); -#187=IFCCLASSIFICATIONREFERENCE($,'13-33 15 15','Indoor Firing Range',#184,$,$); -#188=IFCCLASSIFICATIONREFERENCE($,'13-33 15 17','Outdoor Shooting Range',#184,$,$); -#189=IFCCLASSIFICATIONREFERENCE($,'13-33 15 19','Recreational Deck',#184,$,$); -#190=IFCCLASSIFICATIONREFERENCE($,'13-33 15 21','Playground',#184,$,$); -#191=IFCCLASSIFICATIONREFERENCE($,'13-33 15 23','Game Room',#184,$,$); -#192=IFCCLASSIFICATIONREFERENCE($,'13-33 15 25','Gambling Table',#184,$,$); -#193=IFCCLASSIFICATIONREFERENCE($,'13-33 15 27','Amusement Ride',#184,$,$); -#194=IFCCLASSIFICATIONREFERENCE($,'13-33 15 29','Parade Grounds',#184,$,$); -#195=IFCCLASSIFICATIONREFERENCE($,'13-33 15 31','Computer-Aided Visual Environment',#184,$,$); -#196=IFCCLASSIFICATIONREFERENCE($,'13-33 15 33','Hobby and Craft Center',#184,$,$); -#197=IFCCLASSIFICATIONREFERENCE($,'13-33 15 35','Dance Floors',#184,$,$); -#198=IFCCLASSIFICATIONREFERENCE($,'13-33 17 00','Wellness Spaces',#143,$,$); -#199=IFCCLASSIFICATIONREFERENCE($,'13-33 17 11','Fitness Center',#198,$,$); -#200=IFCCLASSIFICATIONREFERENCE($,'13-33 17 11 11','Exercise Room',#199,$,$); -#201=IFCCLASSIFICATIONREFERENCE($,'13-33 17 11 13','Weight Room',#199,$,$); -#202=IFCCLASSIFICATIONREFERENCE($,'13-35 00 00','Government Spaces',#2,$,$); -#203=IFCCLASSIFICATIONREFERENCE($,'13-35 11 00','Judicial Spaces',#202,$,$); -#204=IFCCLASSIFICATIONREFERENCE($,'13-35 11 11','Courtroom',#203,$,$); -#205=IFCCLASSIFICATIONREFERENCE($,'13-35 11 11 11','Jury Box',#204,$,$); -#206=IFCCLASSIFICATIONREFERENCE($,'13-35 11 11 13','Jury Room',#204,$,$); -#207=IFCCLASSIFICATIONREFERENCE($,'13-35 11 11 15','Judge\X2\2019\X0\s Bench',#204,$,$); -#208=IFCCLASSIFICATIONREFERENCE($,'13-35 11 11 17','Evidence Room',#204,$,$); -#209=IFCCLASSIFICATIONREFERENCE($,'13-35 11 11 19','Jury Assembly Space',#204,$,$); -#210=IFCCLASSIFICATIONREFERENCE($,'13-35 11 11 21','Witness Stand',#204,$,$); -#211=IFCCLASSIFICATIONREFERENCE($,'13-35 11 13','Judge\X2\2019\X0\s Chambers',#203,$,$); -#212=IFCCLASSIFICATIONREFERENCE($,'13-35 11 13 11','JCC\X2\2013\X0\Judicial Chambers',#211,$,$); -#213=IFCCLASSIFICATIONREFERENCE($,'13-35 11 13 13','Law Clerk Space',#211,$,$); -#214=IFCCLASSIFICATIONREFERENCE($,'13-35 11 15','Robing Area/Room',#203,$,$); -#215=IFCCLASSIFICATIONREFERENCE($,'13-35 11 19','Hearing Room',#203,$,$); -#216=IFCCLASSIFICATIONREFERENCE($,'13-35 11 19 11','JHR\X2\2013\X0\Judicial Hearing Room',#215,$,$); -#217=IFCCLASSIFICATIONREFERENCE($,'13-35 13 00','Legislative Spaces',#202,$,$); -#218=IFCCLASSIFICATIONREFERENCE($,'13-35 13 11','Council Chambers',#217,$,$); -#219=IFCCLASSIFICATIONREFERENCE($,'13-35 13 13','Legislative Hearing Room',#217,$,$); -#220=IFCCLASSIFICATIONREFERENCE($,'13-35 15 00','Military Spaces',#202,$,$); -#221=IFCCLASSIFICATIONREFERENCE($,'13-35 15 11','Armory',#220,$,$); -#222=IFCCLASSIFICATIONREFERENCE($,'13-35 15 13','Armory Service Space',#220,$,$); -#223=IFCCLASSIFICATIONREFERENCE($,'13-37 00 00','Artistic Spaces',#2,$,$); -#224=IFCCLASSIFICATIONREFERENCE($,'13-37 11 00','Performance Spaces',#223,$,$); -#225=IFCCLASSIFICATIONREFERENCE($,'13-37 11 11','Outdoor Theater',#224,$,$); -#226=IFCCLASSIFICATIONREFERENCE($,'13-37 11 13','General Performance Spaces',#224,$,$); -#227=IFCCLASSIFICATIONREFERENCE($,'13-37 11 13 11','Acting Stage',#226,$,$); -#228=IFCCLASSIFICATIONREFERENCE($,'13-37 11 13 13','Orchestra Pit',#226,$,$); -#229=IFCCLASSIFICATIONREFERENCE($,'13-37 11 13 15','Performance Rehearsal Space',#226,$,$); -#230=IFCCLASSIFICATIONREFERENCE($,'13-37 11 13 17','Soundstage',#226,$,$); -#231=IFCCLASSIFICATIONREFERENCE($,'13-37 11 13 19','Performance Hall',#226,$,$); -#232=IFCCLASSIFICATIONREFERENCE($,'13-37 11 13 21','Band Training Space',#226,$,$); -#233=IFCCLASSIFICATIONREFERENCE($,'13-37 11 15','Audience Spaces',#224,$,$); -#234=IFCCLASSIFICATIONREFERENCE($,'13-37 11 15 11','Pre-Function Lobby',#233,$,$); -#235=IFCCLASSIFICATIONREFERENCE($,'13-37 11 15 13','Audience Seating Space',#233,$,$); -#236=IFCCLASSIFICATIONREFERENCE($,'13-37 11 17','Supporting Performance Spaces',#224,$,$); -#237=IFCCLASSIFICATIONREFERENCE($,'13-37 11 17 11','Projection Booth',#236,$,$); -#238=IFCCLASSIFICATIONREFERENCE($,'13-37 11 17 13','Catwalk',#236,$,$); -#239=IFCCLASSIFICATIONREFERENCE($,'13-37 11 17 15','Stage Wings',#236,$,$); -#240=IFCCLASSIFICATIONREFERENCE($,'13-37 11 17 17','Motion Picture Screen Space',#236,$,$); -#241=IFCCLASSIFICATIONREFERENCE($,'13-37 13 00','Display Spaces',#223,$,$); -#242=IFCCLASSIFICATIONREFERENCE($,'13-37 13 11','Art Gallery',#241,$,$); -#243=IFCCLASSIFICATIONREFERENCE($,'13-37 13 13','Exhibit Gallery',#241,$,$); -#244=IFCCLASSIFICATIONREFERENCE($,'13-37 13 15','Sculpture Garden',#241,$,$); -#245=IFCCLASSIFICATIONREFERENCE($,'13-37 13 17','Ornamental Garden',#241,$,$); -#246=IFCCLASSIFICATIONREFERENCE($,'13-37 13 19','Observation Deck',#241,$,$); -#247=IFCCLASSIFICATIONREFERENCE($,'13-37 15 00','Creative Spaces',#223,$,$); -#248=IFCCLASSIFICATIONREFERENCE($,'13-37 15 11','Recording Studio',#247,$,$); -#249=IFCCLASSIFICATIONREFERENCE($,'13-37 15 13','Artist\X2\2019\X0\s Studio',#247,$,$); -#250=IFCCLASSIFICATIONREFERENCE($,'13-37 15 15','Photo Lab',#247,$,$); -#251=IFCCLASSIFICATIONREFERENCE($,'13-37 15 15 11','Motion Picture Exchange',#250,$,$); -#252=IFCCLASSIFICATIONREFERENCE($,'13-37 15 17','Media Production',#247,$,$); -#253=IFCCLASSIFICATIONREFERENCE($,'13-37 15 17 11','Media Production Support',#252,$,$); -#254=IFCCLASSIFICATIONREFERENCE($,'13-37 15 17 13','Sound Lock',#252,$,$); -#255=IFCCLASSIFICATIONREFERENCE($,'13-37 15 19','Zen Garden',#247,$,$); -#256=IFCCLASSIFICATIONREFERENCE($,'13-41 00 00','Museum Spaces',#2,$,$); -#257=IFCCLASSIFICATIONREFERENCE($,'13-41 11 00','Museum Gallery',#256,$,$); -#258=IFCCLASSIFICATIONREFERENCE($,'13-45 00 00','Library Spaces',#2,$,$); -#259=IFCCLASSIFICATIONREFERENCE($,'13-45 11 00','Library',#258,$,$); -#260=IFCCLASSIFICATIONREFERENCE($,'13-45 11 11','Library Stack',#259,$,$); -#261=IFCCLASSIFICATIONREFERENCE($,'13-47 00 00','Spiritual Spaces',#2,$,$); -#262=IFCCLASSIFICATIONREFERENCE($,'13-47 11 00','Worship spaces',#261,$,$); -#263=IFCCLASSIFICATIONREFERENCE($,'13-47 11 11','Meditation Chapel',#262,$,$); -#264=IFCCLASSIFICATIONREFERENCE($,'13-47 11 13','Altar',#262,$,$); -#265=IFCCLASSIFICATIONREFERENCE($,'13-47 11 15','Reflection Space',#262,$,$); -#266=IFCCLASSIFICATIONREFERENCE($,'13-47 11 17','Blessing Space',#262,$,$); -#267=IFCCLASSIFICATIONREFERENCE($,'13-47 11 19','Chapel',#262,$,$); -#268=IFCCLASSIFICATIONREFERENCE($,'13-47 11 21','Mihrab',#262,$,$); -#269=IFCCLASSIFICATIONREFERENCE($,'13-47 11 23','Shrine',#262,$,$); -#270=IFCCLASSIFICATIONREFERENCE($,'13-47 11 25','Sanctuary',#262,$,$); -#271=IFCCLASSIFICATIONREFERENCE($,'13-47 11 27','Confessional Space',#262,$,$); -#272=IFCCLASSIFICATIONREFERENCE($,'13-47 11 29','Ark',#262,$,$); -#273=IFCCLASSIFICATIONREFERENCE($,'13-47 11 31','Bimah',#262,$,$); -#274=IFCCLASSIFICATIONREFERENCE($,'13-47 11 33','Tabernacle',#262,$,$); -#275=IFCCLASSIFICATIONREFERENCE($,'13-47 11 35','Pulpit',#262,$,$); -#276=IFCCLASSIFICATIONREFERENCE($,'13-47 11 37','Choir Loft',#262,$,$); -#277=IFCCLASSIFICATIONREFERENCE($,'13-47 13 00','Ceremonial Spaces',#261,$,$); -#278=IFCCLASSIFICATIONREFERENCE($,'13-47 13 11','Marriage Sanctuary',#277,$,$); -#279=IFCCLASSIFICATIONREFERENCE($,'13-47 13 13','Baptistery',#277,$,$); -#280=IFCCLASSIFICATIONREFERENCE($,'13-47 13 15','Circumcision Space',#277,$,$); -#281=IFCCLASSIFICATIONREFERENCE($,'13-47 13 17','Cathedra',#277,$,$); -#282=IFCCLASSIFICATIONREFERENCE($,'13-47 15 00','Procession Spaces',#261,$,$); -#283=IFCCLASSIFICATIONREFERENCE($,'13-47 17 00','Death Spaces',#261,$,$); -#284=IFCCLASSIFICATIONREFERENCE($,'13-47 17 11','Crypt',#283,$,$); -#285=IFCCLASSIFICATIONREFERENCE($,'13-47 17 13','Morgue',#283,$,$); -#286=IFCCLASSIFICATIONREFERENCE($,'13-47 17 13 11','Morgue Compartment',#285,$,$); -#287=IFCCLASSIFICATIONREFERENCE($,'13-47 17 17','Grave Space',#283,$,$); -#288=IFCCLASSIFICATIONREFERENCE($,'13-49 00 00','Environmentally Controlled Spaces',#2,$,$); -#289=IFCCLASSIFICATIONREFERENCE($,'13-49 11 00','Anechoic Chamber',#288,$,$); -#290=IFCCLASSIFICATIONREFERENCE($,'13-49 13 00','Hazard Containment',#288,$,$); -#291=IFCCLASSIFICATIONREFERENCE($,'13-49 15 00','Clean Room',#288,$,$); -#292=IFCCLASSIFICATIONREFERENCE($,'13-49 15 11','Clean Room Class 1',#291,$,$); -#293=IFCCLASSIFICATIONREFERENCE($,'13-49 15 13','Clean Room Class 2',#291,$,$); -#294=IFCCLASSIFICATIONREFERENCE($,'13-49 15 15','Clean Room Class 3',#291,$,$); -#295=IFCCLASSIFICATIONREFERENCE($,'13-49 15 17','Clean Room Class 4',#291,$,$); -#296=IFCCLASSIFICATIONREFERENCE($,'13-49 15 19','Clean Room Class 5',#291,$,$); -#297=IFCCLASSIFICATIONREFERENCE($,'13-49 15 21','Clean Room Class 6',#291,$,$); -#298=IFCCLASSIFICATIONREFERENCE($,'13-49 15 23','Clean Room Class 7',#291,$,$); -#299=IFCCLASSIFICATIONREFERENCE($,'13-49 15 25','Clean Room Class 8',#291,$,$); -#300=IFCCLASSIFICATIONREFERENCE($,'13-49 15 27','Clean Room Class 9',#291,$,$); -#301=IFCCLASSIFICATIONREFERENCE($,'13-49 15 29','Clean Room Support Space',#291,$,$); -#302=IFCCLASSIFICATIONREFERENCE($,'13-49 17 00','Temperature and Pressure Chamber',#288,$,$); -#303=IFCCLASSIFICATIONREFERENCE($,'13-49 19 00','Data Center',#288,$,$); -#304=IFCCLASSIFICATIONREFERENCE($,'13-49 19 11','Data Center Tier I',#303,$,$); -#305=IFCCLASSIFICATIONREFERENCE($,'13-49 19 13','Data Center Tier II',#303,$,$); -#306=IFCCLASSIFICATIONREFERENCE($,'13-49 19 15','Data Center Tier III',#303,$,$); -#307=IFCCLASSIFICATIONREFERENCE($,'13-49 19 17','Data Center Tier IV',#303,$,$); -#308=IFCCLASSIFICATIONREFERENCE($,'13-49 19 19','Data Center Support Space',#303,$,$); -#309=IFCCLASSIFICATIONREFERENCE($,'13-49 21 00','Controlled Space Support',#288,$,$); -#310=IFCCLASSIFICATIONREFERENCE($,'13-49 23 00','Miscellaneous Environmentally Controlled Spaces',#288,$,$); -#311=IFCCLASSIFICATIONREFERENCE($,'13-49 23 11','Film Storage Vault',#310,$,$); -#312=IFCCLASSIFICATIONREFERENCE($,'13-49 23 13','Computer Server Room',#310,$,$); -#313=IFCCLASSIFICATIONREFERENCE($,'13-51 00 00','Healthcare Spaces',#2,$,$); -#314=IFCCLASSIFICATIONREFERENCE($,'13-51 11 00','General Examination Spaces',#313,$,$); -#315=IFCCLASSIFICATIONREFERENCE($,'13-51 11 11','Exam Room',#314,$,$); -#316=IFCCLASSIFICATIONREFERENCE($,'13-51 11 13','Exam Room, Airborne Infection Isolation',#314,$,$); -#317=IFCCLASSIFICATIONREFERENCE($,'13-51 11 15','Exam Room, Isolation',#314,$,$); -#318=IFCCLASSIFICATIONREFERENCE($,'13-51 11 17','Exam Room, OB/Gyn',#314,$,$); -#319=IFCCLASSIFICATIONREFERENCE($,'13-51 11 19','Exam Room, Pediatric',#314,$,$); -#320=IFCCLASSIFICATIONREFERENCE($,'13-51 11 21','Exam Room, Protective Environment Isolation',#314,$,$); -#321=IFCCLASSIFICATIONREFERENCE($,'13-51 11 23','Exam Room, Podiatry',#314,$,$); -#322=IFCCLASSIFICATIONREFERENCE($,'13-51 11 25','Exam Room, Security',#314,$,$); -#323=IFCCLASSIFICATIONREFERENCE($,'13-51 11 27','Height/Weight Screening Space',#314,$,$); -#324=IFCCLASSIFICATIONREFERENCE($,'13-51 11 29','Holding Room, Secured',#314,$,$); -#325=IFCCLASSIFICATIONREFERENCE($,'13-51 14 00','Inpatient Care Spaces',#313,$,$); -#326=IFCCLASSIFICATIONREFERENCE($,'13-51 14 11','Anteroom, Inpatient Airborne Infection Isolation',#325,$,$); -#327=IFCCLASSIFICATIONREFERENCE($,'13-51 14 13','Anteroom, Inpatient Protective Environment Isolation',#325,$,$); -#328=IFCCLASSIFICATIONREFERENCE($,'13-51 14 17','Anteroom, Inpatient Isolation/Seclusion',#325,$,$); -#329=IFCCLASSIFICATIONREFERENCE($,'13-51 14 19','Labor, Delivery, Recovery, Postpartum Room',#325,$,$); -#330=IFCCLASSIFICATIONREFERENCE($,'13-51 14 21','Medical Information Computer System Room',#325,$,$); -#331=IFCCLASSIFICATIONREFERENCE($,'13-51 14 23','Newborn Nursery',#325,$,$); -#332=IFCCLASSIFICATIONREFERENCE($,'13-51 14 25','NICU Nursery',#325,$,$); -#333=IFCCLASSIFICATIONREFERENCE($,'13-51 14 27','Nursery Transport Unit Alcove',#325,$,$); -#334=IFCCLASSIFICATIONREFERENCE($,'13-51 14 29','Nursery, Airborne Infection Isolation',#325,$,$); -#335=IFCCLASSIFICATIONREFERENCE($,'13-51 14 31','Nursery, Observation',#325,$,$); -#336=IFCCLASSIFICATIONREFERENCE($,'13-51 14 33','Nursery, Special Care',#325,$,$); -#337=IFCCLASSIFICATIONREFERENCE($,'13-51 14 35','Patient Room',#325,$,$); -#338=IFCCLASSIFICATIONREFERENCE($,'13-51 14 35 11','Patient Room, Airborne Infection Isolation',#337,$,$); -#339=IFCCLASSIFICATIONREFERENCE($,'13-51 14 35 13','Patient Room, Bariatric',#337,$,$); -#340=IFCCLASSIFICATIONREFERENCE($,'13-51 14 35 15','Patient Room, Intensive Care',#337,$,$); -#341=IFCCLASSIFICATIONREFERENCE($,'13-51 14 35 17','Patient Room, Intensive Care, Airborne Infection Isolation',#337,$,$); -#342=IFCCLASSIFICATIONREFERENCE($,'13-51 14 35 19','Patient Room, Intensive Care, Protective Environment Isolation',#337,$,$); -#343=IFCCLASSIFICATIONREFERENCE($,'13-51 14 35 21','Patient Room, Isolation',#337,$,$); -#344=IFCCLASSIFICATIONREFERENCE($,'13-51 14 35 23','Patient Room, Monitored',#337,$,$); -#345=IFCCLASSIFICATIONREFERENCE($,'13-51 14 35 25','Patient Room, One-Bed',#337,$,$); -#346=IFCCLASSIFICATIONREFERENCE($,'13-51 14 35 27','Patient Room, Protective Environment Isolation',#337,$,$); -#347=IFCCLASSIFICATIONREFERENCE($,'13-51 14 35 29','Patient Room, Seclusion',#337,$,$); -#348=IFCCLASSIFICATIONREFERENCE($,'13-51 14 35 31','Patient Room, Transitional, One-Bed',#337,$,$); -#349=IFCCLASSIFICATIONREFERENCE($,'13-51 14 35 33','Patient Room, Two-Bed',#337,$,$); -#350=IFCCLASSIFICATIONREFERENCE($,'13-51 17 00','Multi-Medical Service Support Spaces',#313,$,$); -#351=IFCCLASSIFICATIONREFERENCE($,'13-51 17 11','Clean Linen Storage Room, Healthcare',#350,$,$); -#352=IFCCLASSIFICATIONREFERENCE($,'13-51 17 13','Clean Supply Room, Healthcare',#350,$,$); -#353=IFCCLASSIFICATIONREFERENCE($,'13-51 17 15','Clean Utility Room, Healthcare',#350,$,$); -#354=IFCCLASSIFICATIONREFERENCE($,'13-51 17 17','Consultation Room, Patient',#350,$,$); -#355=IFCCLASSIFICATIONREFERENCE($,'13-51 17 19','Mental Health Interview/Counseling Room',#350,$,$); -#356=IFCCLASSIFICATIONREFERENCE($,'13-51 17 21','Equipment Storage Room, Healthcare',#350,$,$); -#357=IFCCLASSIFICATIONREFERENCE($,'13-51 17 22','Medical Records Storage Room',#350,$,$); -#358=IFCCLASSIFICATIONREFERENCE($,'13-51 17 23','Nurse Workspaces',#350,$,$); -#359=IFCCLASSIFICATIONREFERENCE($,'13-51 17 23 11','Nurse Station',#358,$,$); -#360=IFCCLASSIFICATIONREFERENCE($,'13-51 17 23 13','Nurse Station/Communication Center',#358,$,$); -#361=IFCCLASSIFICATIONREFERENCE($,'13-51 17 23 15','Nurse Sub-Station',#358,$,$); -#362=IFCCLASSIFICATIONREFERENCE($,'13-51 17 23 17','Nurse Triage Space',#358,$,$); -#363=IFCCLASSIFICATIONREFERENCE($,'13-51 17 25','Soiled Utility Room, Healthcare',#350,$,$); -#364=IFCCLASSIFICATIONREFERENCE($,'13-51 17 27','Soiled Utility/Supply Room, Healthcare',#350,$,$); -#365=IFCCLASSIFICATIONREFERENCE($,'13-51 17 29','Mental Health Multipurpose Room w/Control Room',#350,$,$); -#366=IFCCLASSIFICATIONREFERENCE($,'13-51 17 31','Resuscitation Cart Alcove',#350,$,$); -#367=IFCCLASSIFICATIONREFERENCE($,'13-51 17 35','Mental Health Quiet Room',#350,$,$); -#368=IFCCLASSIFICATIONREFERENCE($,'13-51 21 00','Diagnostic Imaging Spaces',#313,$,$); -#369=IFCCLASSIFICATIONREFERENCE($,'13-51 21 11','Angiographic Procedure Room',#368,$,$); -#370=IFCCLASSIFICATIONREFERENCE($,'13-51 21 13','Bone Densitometry Room',#368,$,$); -#371=IFCCLASSIFICATIONREFERENCE($,'13-51 21 15','CT Scanning Room',#368,$,$); -#372=IFCCLASSIFICATIONREFERENCE($,'13-51 21 17','CT Simulator Room',#368,$,$); -#373=IFCCLASSIFICATIONREFERENCE($,'13-51 21 19','Cystoscopic Radiology Room',#368,$,$); -#374=IFCCLASSIFICATIONREFERENCE($,'13-51 21 21','Head Radiographic Room',#368,$,$); -#375=IFCCLASSIFICATIONREFERENCE($,'13-51 21 23','Mammography Room',#368,$,$); -#376=IFCCLASSIFICATIONREFERENCE($,'13-51 21 25','Mobile Imaging System Alcove',#368,$,$); -#377=IFCCLASSIFICATIONREFERENCE($,'13-51 21 27','MRI Scanning Room',#368,$,$); -#378=IFCCLASSIFICATIONREFERENCE($,'13-51 21 29','MRI System Component Room',#368,$,$); -#379=IFCCLASSIFICATIONREFERENCE($,'13-51 21 31','PET/CT Scanning Room',#368,$,$); -#380=IFCCLASSIFICATIONREFERENCE($,'13-51 21 33','PET/CT Simulator Room',#368,$,$); -#381=IFCCLASSIFICATIONREFERENCE($,'13-51 21 35','Radiographic Chest Room',#368,$,$); -#382=IFCCLASSIFICATIONREFERENCE($,'13-51 21 37','Radiographic Room',#368,$,$); -#383=IFCCLASSIFICATIONREFERENCE($,'13-51 21 39','Radiographic/Fluoroscopic Room',#368,$,$); -#384=IFCCLASSIFICATIONREFERENCE($,'13-51 21 41','Radiographic/Tomographic Room',#368,$,$); -#385=IFCCLASSIFICATIONREFERENCE($,'13-51 21 43','Radiology Computer Systems Room',#368,$,$); -#386=IFCCLASSIFICATIONREFERENCE($,'13-51 21 45','Stereotactic Mammography Room',#368,$,$); -#387=IFCCLASSIFICATIONREFERENCE($,'13-51 21 47','Ultrasound Room',#368,$,$); -#388=IFCCLASSIFICATIONREFERENCE($,'13-51 21 49','Ultrasound/Optical Coherence Tomography Room',#368,$,$); -#389=IFCCLASSIFICATIONREFERENCE($,'13-51 21 51','Whole Body Scanning Room',#368,$,$); -#390=IFCCLASSIFICATIONREFERENCE($,'13-51 24 00','Diagnostic Imaging Support Spaces',#313,$,$); -#391=IFCCLASSIFICATIONREFERENCE($,'13-51 24 11','Angiographic Control Room',#390,$,$); -#392=IFCCLASSIFICATIONREFERENCE($,'13-51 24 13','Angiographic Instrument Room',#390,$,$); -#393=IFCCLASSIFICATIONREFERENCE($,'13-51 24 15','Angiographic Procedure Control Area',#390,$,$); -#394=IFCCLASSIFICATIONREFERENCE($,'13-51 24 17','Angiographic System Component Room',#390,$,$); -#395=IFCCLASSIFICATIONREFERENCE($,'13-51 24 19','Silver Collection Area, Diagnostic Imaging',#390,$,$); -#396=IFCCLASSIFICATIONREFERENCE($,'13-51 24 21','Computed Radiology Reader Area',#390,$,$); -#397=IFCCLASSIFICATIONREFERENCE($,'13-51 24 23','Computer Image Processing Area, Diagnostic Imaging',#390,$,$); -#398=IFCCLASSIFICATIONREFERENCE($,'13-51 24 24','X-Ray, Digital Image Storage Space',#390,$,$); -#399=IFCCLASSIFICATIONREFERENCE($,'13-51 24 25','CT Control Area',#390,$,$); -#400=IFCCLASSIFICATIONREFERENCE($,'13-51 24 27','CT Power and Equipment Room',#390,$,$); -#401=IFCCLASSIFICATIONREFERENCE($,'13-51 24 29','Image Quality Control Room',#390,$,$); -#402=IFCCLASSIFICATIONREFERENCE($,'13-51 24 31','Image Reading Room',#390,$,$); -#403=IFCCLASSIFICATIONREFERENCE($,'13-51 24 32','X-Ray, Plane Film Storage Space',#390,$,$); -#404=IFCCLASSIFICATIONREFERENCE($,'13-51 24 33','Mammography Processing Room',#390,$,$); -#405=IFCCLASSIFICATIONREFERENCE($,'13-51 24 34','X-Ray Film, Daylight Processing Space',#390,$,$); -#406=IFCCLASSIFICATIONREFERENCE($,'13-51 24 35','MRI Control Room',#390,$,$); -#407=IFCCLASSIFICATIONREFERENCE($,'13-51 24 37','MRI Equipment Storage Room',#390,$,$); -#408=IFCCLASSIFICATIONREFERENCE($,'13-51 24 39','MRI Viewing Room',#390,$,$); -#409=IFCCLASSIFICATIONREFERENCE($,'13-51 24 41','PET/CT Control Room',#390,$,$); -#410=IFCCLASSIFICATIONREFERENCE($,'13-51 24 43','Radiographic Control Room',#390,$,$); -#411=IFCCLASSIFICATIONREFERENCE($,'13-51 24 45','Radiographic Darkroom',#390,$,$); -#412=IFCCLASSIFICATIONREFERENCE($,'13-51 24 47','Tele-Radiology/Tele-Medicine Room',#390,$,$); -#413=IFCCLASSIFICATIONREFERENCE($,'13-51 24 49','Viewing/Consultation Room, Diagnostic Imaging',#390,$,$); -#414=IFCCLASSIFICATIONREFERENCE($,'13-51 24 51','X-Ray, Mobile C-Arm Alcove',#390,$,$); -#415=IFCCLASSIFICATIONREFERENCE($,'13-51 27 00','Radiation Diagnostic and Therapy Spaces',#313,$,$); -#416=IFCCLASSIFICATIONREFERENCE($,'13-51 27 11','Equipment Calibration Space, Radiation Diagnostic and Therapy',#415,$,$); -#417=IFCCLASSIFICATIONREFERENCE($,'13-51 27 13','Health Physics Laboratory',#415,$,$); -#418=IFCCLASSIFICATIONREFERENCE($,'13-51 27 15','Linear Accelerator Component Room, Healthcare',#415,$,$); -#419=IFCCLASSIFICATIONREFERENCE($,'13-51 27 17','Linear Accelerator Entrance Maze, Healthcare',#415,$,$); -#420=IFCCLASSIFICATIONREFERENCE($,'13-51 27 19','Linear Accelerator Room, Healthcare',#415,$,$); -#421=IFCCLASSIFICATIONREFERENCE($,'13-51 27 21','Linear Accelerator Control Room, Healthcare',#415,$,$); -#422=IFCCLASSIFICATIONREFERENCE($,'13-51 27 23','Radioactive Waste Storage Room, Healthcare',#415,$,$); -#423=IFCCLASSIFICATIONREFERENCE($,'13-51 27 25','Nuclear Medicine Dose Calibration Space',#415,$,$); -#424=IFCCLASSIFICATIONREFERENCE($,'13-51 27 27','Nuclear Medicine Scanning Room',#415,$,$); -#425=IFCCLASSIFICATIONREFERENCE($,'13-51 27 29','Nuclear Medicine Patient "Hot" Waiting Room',#415,$,$); -#426=IFCCLASSIFICATIONREFERENCE($,'13-51 27 31','Patient Dose/Thyroid Uptake Room',#415,$,$); -#427=IFCCLASSIFICATIONREFERENCE($,'13-51 27 33','Radiation Dosimetry Planning Room',#415,$,$); -#428=IFCCLASSIFICATIONREFERENCE($,'13-51 27 35','Radiopharmacy',#415,$,$); -#429=IFCCLASSIFICATIONREFERENCE($,'13-51 27 37','Radium Cart Holding Space',#415,$,$); -#430=IFCCLASSIFICATIONREFERENCE($,'13-51 27 38','Radiation Therapy, Mold Fabrication Shop',#415,$,$); -#431=IFCCLASSIFICATIONREFERENCE($,'13-51 27 39','Sealed Source Room',#415,$,$); -#432=IFCCLASSIFICATIONREFERENCE($,'13-51 31 00','Heart and Lung Diagnostic and Treatment Spaces',#313,$,$); -#433=IFCCLASSIFICATIONREFERENCE($,'13-51 31 11','Brachytherapy Room',#432,$,$); -#434=IFCCLASSIFICATIONREFERENCE($,'13-51 31 13','Cardiac Catheter Instrument Room',#432,$,$); -#435=IFCCLASSIFICATIONREFERENCE($,'13-51 31 15','Cardiac Catheter System Component Room',#432,$,$); -#436=IFCCLASSIFICATIONREFERENCE($,'13-51 31 17','Cardiac Catheterization Control Room',#432,$,$); -#437=IFCCLASSIFICATIONREFERENCE($,'13-51 31 19','Cardiac Catheterization Laboratory',#432,$,$); -#438=IFCCLASSIFICATIONREFERENCE($,'13-51 31 21','Cardiac Electrophysiology Room',#432,$,$); -#439=IFCCLASSIFICATIONREFERENCE($,'13-51 31 23','Cardiac Testing Room',#432,$,$); -#440=IFCCLASSIFICATIONREFERENCE($,'13-51 31 25','Echocardiograph Room',#432,$,$); -#441=IFCCLASSIFICATIONREFERENCE($,'13-51 31 27','EKG Testing Room',#432,$,$); -#442=IFCCLASSIFICATIONREFERENCE($,'13-51 31 29','Extended Pulmonary Function Testing Laboratory',#432,$,$); -#443=IFCCLASSIFICATIONREFERENCE($,'13-51 31 31','Microvascular Laboratory',#432,$,$); -#444=IFCCLASSIFICATIONREFERENCE($,'13-51 31 33','Pacemaker ICD Interrogation Room',#432,$,$); -#445=IFCCLASSIFICATIONREFERENCE($,'13-51 31 35','Pacemaker/Holter Monitor Room',#432,$,$); -#446=IFCCLASSIFICATIONREFERENCE($,'13-51 31 37','Procedure Viewing Area',#432,$,$); -#447=IFCCLASSIFICATIONREFERENCE($,'13-51 31 39','Pulmonary Function Testing Laboratory',#432,$,$); -#448=IFCCLASSIFICATIONREFERENCE($,'13-51 31 40','Pulmonary Function Treadmill Room',#432,$,$); -#449=IFCCLASSIFICATIONREFERENCE($,'13-51 31 41','Pulmonary Screening Room',#432,$,$); -#450=IFCCLASSIFICATIONREFERENCE($,'13-51 31 43','Respiratory Inhalation Cubicle',#432,$,$); -#451=IFCCLASSIFICATIONREFERENCE($,'13-51 31 45','Respiratory Therapy Clean-up Room',#432,$,$); -#452=IFCCLASSIFICATIONREFERENCE($,'13-51 31 47','Spirometry Test Room',#432,$,$); -#453=IFCCLASSIFICATIONREFERENCE($,'13-51 31 49','Stress Echocardiograph Room',#432,$,$); -#454=IFCCLASSIFICATIONREFERENCE($,'13-51 31 51','Stress Testing Treadmill Room',#432,$,$); -#455=IFCCLASSIFICATIONREFERENCE($,'13-51 31 53','Transesophageal Echocardiography Room',#432,$,$); -#456=IFCCLASSIFICATIONREFERENCE($,'13-51 34 00','General Diagnostic Procedure and Treatment Spaces',#313,$,$); -#457=IFCCLASSIFICATIONREFERENCE($,'13-51 34 11','Allergen Preparation Space',#456,$,$); -#458=IFCCLASSIFICATIONREFERENCE($,'13-51 34 13','Allergy Injection Room',#456,$,$); -#459=IFCCLASSIFICATIONREFERENCE($,'13-51 34 15','Allergy Skin Testing',#456,$,$); -#460=IFCCLASSIFICATIONREFERENCE($,'13-51 34 17','Antepartum Testing (NST) Room',#456,$,$); -#461=IFCCLASSIFICATIONREFERENCE($,'13-51 34 19','Biofeedback Treatment Control/Office',#456,$,$); -#462=IFCCLASSIFICATIONREFERENCE($,'13-51 34 21','Biofeedback Treatment Room',#456,$,$); -#463=IFCCLASSIFICATIONREFERENCE($,'13-51 34 23','Cast and Splint Room',#456,$,$); -#464=IFCCLASSIFICATIONREFERENCE($,'13-51 34 25','Chemotherapy Treatment Room',#456,$,$); -#465=IFCCLASSIFICATIONREFERENCE($,'13-51 34 27','Dermatology Cryotherapy Space',#456,$,$); -#466=IFCCLASSIFICATIONREFERENCE($,'13-51 34 29','Dermatology Procedure Room',#456,$,$); -#467=IFCCLASSIFICATIONREFERENCE($,'13-51 34 31','Dialysis Clean Equipment Preparation Room',#456,$,$); -#468=IFCCLASSIFICATIONREFERENCE($,'13-51 34 33','Dialysis Soiled Equipment Processing',#456,$,$); -#469=IFCCLASSIFICATIONREFERENCE($,'13-51 34 35','Dialysis Training Room',#456,$,$); -#470=IFCCLASSIFICATIONREFERENCE($,'13-51 34 37','EEG Exam Room',#456,$,$); -#471=IFCCLASSIFICATIONREFERENCE($,'13-51 34 39','EEG Instrument and Work Room',#456,$,$); -#472=IFCCLASSIFICATIONREFERENCE($,'13-51 34 41','EEG/Sleep Study Monitoring Room',#456,$,$); -#473=IFCCLASSIFICATIONREFERENCE($,'13-51 34 43','Electromyography Room',#456,$,$); -#474=IFCCLASSIFICATIONREFERENCE($,'13-51 34 45','ENT Procedure Room',#456,$,$); -#475=IFCCLASSIFICATIONREFERENCE($,'13-51 34 47','Evoked Potential Response Room',#456,$,$); -#476=IFCCLASSIFICATIONREFERENCE($,'13-51 34 49','General Purpose Dirty Treatment Room',#456,$,$); -#477=IFCCLASSIFICATIONREFERENCE($,'13-51 34 51','Immunization Room',#456,$,$); -#478=IFCCLASSIFICATIONREFERENCE($,'13-51 34 53','Infectious Disease Decontamination Shower',#456,$,$); -#479=IFCCLASSIFICATIONREFERENCE($,'13-51 34 55','Infectious Disease Decontamination Suite',#456,$,$); -#480=IFCCLASSIFICATIONREFERENCE($,'13-51 34 57','Life Support Unit Room',#456,$,$); -#481=IFCCLASSIFICATIONREFERENCE($,'13-51 34 61','OB/GYN Treatment Room',#456,$,$); -#482=IFCCLASSIFICATIONREFERENCE($,'13-51 34 63','Patient Observation and Treatment Room',#456,$,$); -#483=IFCCLASSIFICATIONREFERENCE($,'13-51 34 65','Pentamidine Treatment Room',#456,$,$); -#484=IFCCLASSIFICATIONREFERENCE($,'13-51 34 67','Peritoneal Dialysis Exam Room',#456,$,$); -#485=IFCCLASSIFICATIONREFERENCE($,'13-51 34 69','Peritoneal Dialysis Procedure Room',#456,$,$); -#486=IFCCLASSIFICATIONREFERENCE($,'13-51 34 71','Phototherapy Treatment Room',#456,$,$); -#487=IFCCLASSIFICATIONREFERENCE($,'13-51 34 73','Renal Dialysis Bed Station, Private',#456,$,$); -#488=IFCCLASSIFICATIONREFERENCE($,'13-51 34 75','Renal Dialysis Room, Negative Pressure',#456,$,$); -#489=IFCCLASSIFICATIONREFERENCE($,'13-51 34 77','Renal Dialysis, Chair Station, Cubicle',#456,$,$); -#490=IFCCLASSIFICATIONREFERENCE($,'13-51 34 78','Renal Dialysis, Water Treatment Room',#456,$,$); -#491=IFCCLASSIFICATIONREFERENCE($,'13-51 34 79','Sleep Study Room',#456,$,$); -#492=IFCCLASSIFICATIONREFERENCE($,'13-51 34 81','Provider Trainee Observation Area, Healthcare',#456,$,$); -#493=IFCCLASSIFICATIONREFERENCE($,'13-51 34 83','Treatment Cubicle, Healthcare',#456,$,$); -#494=IFCCLASSIFICATIONREFERENCE($,'13-51 34 85','Treatment Room, Healthcare',#456,$,$); -#495=IFCCLASSIFICATIONREFERENCE($,'13-51 34 87','Neuropsychology Testing Laboratory',#456,$,$); -#496=IFCCLASSIFICATIONREFERENCE($,'13-51 37 00','Eye and Ear Healthcare Spaces',#313,$,$); -#497=IFCCLASSIFICATIONREFERENCE($,'13-51 37 11','Audiology Immittance Room',#496,$,$); -#498=IFCCLASSIFICATIONREFERENCE($,'13-51 37 13','Audiometric Exam Booth',#496,$,$); -#499=IFCCLASSIFICATIONREFERENCE($,'13-51 37 15','Audiometric Exam Suite',#496,$,$); -#500=IFCCLASSIFICATIONREFERENCE($,'13-51 37 17','Audiometric Multi-Exam Suite',#496,$,$); -#501=IFCCLASSIFICATIONREFERENCE($,'13-51 37 19','Audiology Electrophysiology Exam Room',#496,$,$); -#502=IFCCLASSIFICATIONREFERENCE($,'13-51 37 20','Hearing Aid Testing Laboratory',#496,$,$); -#503=IFCCLASSIFICATIONREFERENCE($,'13-51 37 21','Electroretinography Room',#496,$,$); -#504=IFCCLASSIFICATIONREFERENCE($,'13-51 37 23','ENT Exam Room',#496,$,$); -#505=IFCCLASSIFICATIONREFERENCE($,'13-51 37 25','Exam/Training Room, Low Vision',#496,$,$); -#506=IFCCLASSIFICATIONREFERENCE($,'13-51 37 27','Eye Lane',#496,$,$); -#507=IFCCLASSIFICATIONREFERENCE($,'13-51 37 29','Laser Treatment Room',#496,$,$); -#508=IFCCLASSIFICATIONREFERENCE($,'13-51 37 31','Ophthalmology Procedure Room',#496,$,$); -#509=IFCCLASSIFICATIONREFERENCE($,'13-51 37 33','Ophthalmology/Optometry Exam Room',#496,$,$); -#510=IFCCLASSIFICATIONREFERENCE($,'13-51 37 35','Photography Room, Ophthalmology/Optometry',#496,$,$); -#511=IFCCLASSIFICATIONREFERENCE($,'13-51 37 37','PRK/LASIK Treatment Room',#496,$,$); -#512=IFCCLASSIFICATIONREFERENCE($,'13-51 37 39','Sinusoidal Vertical Axis Rotational Rest Room',#496,$,$); -#513=IFCCLASSIFICATIONREFERENCE($,'13-51 37 41','Tilt Table Testing Room',#496,$,$); -#514=IFCCLASSIFICATIONREFERENCE($,'13-51 37 43','Training Room, Low Vision, Polytrauma',#496,$,$); -#515=IFCCLASSIFICATIONREFERENCE($,'13-51 37 45','Ultrasound/Optical Coherence Tomography Room',#496,$,$); -#516=IFCCLASSIFICATIONREFERENCE($,'13-51 37 47','Vestibulography Room',#496,$,$); -#517=IFCCLASSIFICATIONREFERENCE($,'13-51 37 49','Vision/Hearing Screening Room',#496,$,$); -#518=IFCCLASSIFICATIONREFERENCE($,'13-51 37 51','Vision Screening Room',#496,$,$); -#519=IFCCLASSIFICATIONREFERENCE($,'13-51 37 53','Vision Testing Station',#496,$,$); -#520=IFCCLASSIFICATIONREFERENCE($,'13-51 37 55','Visual Fields Room',#496,$,$); -#521=IFCCLASSIFICATIONREFERENCE($,'13-51 37 57','Eye, Contact Lens Fitting/Dispensing Space',#496,$,$); -#522=IFCCLASSIFICATIONREFERENCE($,'13-51 37 59','Eyeglass Fitting and Dispensing Space',#496,$,$); -#523=IFCCLASSIFICATIONREFERENCE($,'13-51 41 00','Endoscopy/Gastroenterology Spaces',#313,$,$); -#524=IFCCLASSIFICATIONREFERENCE($,'13-51 41 11','Bronchoscopy Equipment Preparation Room',#523,$,$); -#525=IFCCLASSIFICATIONREFERENCE($,'13-51 41 13','Bronchoscopy Procedure Room',#523,$,$); -#526=IFCCLASSIFICATIONREFERENCE($,'13-51 41 15','Endoscope Clean-up, Sterilization, and Storage Room',#523,$,$); -#527=IFCCLASSIFICATIONREFERENCE($,'13-51 41 17','Endoscopy Room',#523,$,$); -#528=IFCCLASSIFICATIONREFERENCE($,'13-51 41 19','Gastroenterology Laboratory',#523,$,$); -#529=IFCCLASSIFICATIONREFERENCE($,'13-51 41 21','Proctoscopy/Sigmoidoscopy Room',#523,$,$); -#530=IFCCLASSIFICATIONREFERENCE($,'13-51 41 23','Urodynamics Treatment Room',#523,$,$); -#531=IFCCLASSIFICATIONREFERENCE($,'13-51 44 00','Surgical Spaces',#313,$,$); -#532=IFCCLASSIFICATIONREFERENCE($,'13-51 44 11','Anesthesia Workroom and Equipment Storage',#531,$,$); -#533=IFCCLASSIFICATIONREFERENCE($,'13-51 44 13','Cardiac Operating Room',#531,$,$); -#534=IFCCLASSIFICATIONREFERENCE($,'13-51 44 15','Cardiac Pump Room',#531,$,$); -#535=IFCCLASSIFICATIONREFERENCE($,'13-51 44 17','Cesarean Birth Room',#531,$,$); -#536=IFCCLASSIFICATIONREFERENCE($,'13-51 44 19','Cystoscopy Room',#531,$,$); -#537=IFCCLASSIFICATIONREFERENCE($,'13-51 44 21','Equipment Storage Room, Surgical',#531,$,$); -#538=IFCCLASSIFICATIONREFERENCE($,'13-51 44 23','Frozen Section Laboratory',#531,$,$); -#539=IFCCLASSIFICATIONREFERENCE($,'13-51 44 25','General Operating Room',#531,$,$); -#540=IFCCLASSIFICATIONREFERENCE($,'13-51 44 27','Nerve Block Induction Room',#531,$,$); -#541=IFCCLASSIFICATIONREFERENCE($,'13-51 44 29','Neurosurgery Operating Room',#531,$,$); -#542=IFCCLASSIFICATIONREFERENCE($,'13-51 44 31','Orthopedic Operating Room',#531,$,$); -#543=IFCCLASSIFICATIONREFERENCE($,'13-51 44 33','Patient Holding Area, Surgical',#531,$,$); -#544=IFCCLASSIFICATIONREFERENCE($,'13-51 44 35','Postanesthesia Recovery Cubicle',#531,$,$); -#545=IFCCLASSIFICATIONREFERENCE($,'13-51 44 37','Postanesthesia Recovery Isolation Room',#531,$,$); -#546=IFCCLASSIFICATIONREFERENCE($,'13-51 44 39','Postoperative Recovery Lounge',#531,$,$); -#547=IFCCLASSIFICATIONREFERENCE($,'13-51 44 41','Preparation/Recovery Spaces, Surgical',#531,$,$); -#548=IFCCLASSIFICATIONREFERENCE($,'13-51 44 41 11','Preparation/Recovery Cubicle, Surgical',#547,$,$); -#549=IFCCLASSIFICATIONREFERENCE($,'13-51 44 41 13','Preparation/Recovery Room, Surgical',#547,$,$); -#550=IFCCLASSIFICATIONREFERENCE($,'13-51 44 43','Procedure/Minor Operating Room',#531,$,$); -#551=IFCCLASSIFICATIONREFERENCE($,'13-51 44 45','Scrub/Gowning Area',#531,$,$); -#552=IFCCLASSIFICATIONREFERENCE($,'13-51 44 47','Sub-Sterile Room',#531,$,$); -#553=IFCCLASSIFICATIONREFERENCE($,'13-51 44 50','Operating Room, Sterile Storage',#531,$,$); -#554=IFCCLASSIFICATIONREFERENCE($,'13-51 44 51','Surgical Laser Treatment Room',#531,$,$); -#555=IFCCLASSIFICATIONREFERENCE($,'13-51 44 53','Recovery Room, Surgical',#531,$,$); -#556=IFCCLASSIFICATIONREFERENCE($,'13-51 44 55','Surgical Suite, Workroom and Supply Space',#531,$,$); -#557=IFCCLASSIFICATIONREFERENCE($,'13-51 47 00','Clinical Laboratory Spaces',#313,$,$); -#558=IFCCLASSIFICATIONREFERENCE($,'13-51 47 11','Automated Clinical Laboratory',#557,$,$); -#559=IFCCLASSIFICATIONREFERENCE($,'13-51 47 13','Bioassay (Radioimmunoassay) Room',#557,$,$); -#560=IFCCLASSIFICATIONREFERENCE($,'13-51 47 15','Blood Gas Laboratory',#557,$,$); -#561=IFCCLASSIFICATIONREFERENCE($,'13-51 47 17','Blood Hemotherapeutics Room',#557,$,$); -#562=IFCCLASSIFICATIONREFERENCE($,'13-51 47 19','Bone Dissection Laboratory',#557,$,$); -#563=IFCCLASSIFICATIONREFERENCE($,'13-51 47 21','Clinical Chemistry Laboratory',#557,$,$); -#564=IFCCLASSIFICATIONREFERENCE($,'13-51 47 23','Clinical Microbiology Laboratory',#557,$,$); -#565=IFCCLASSIFICATIONREFERENCE($,'13-51 47 25','Cytology Laboratory',#557,$,$); -#566=IFCCLASSIFICATIONREFERENCE($,'13-51 47 27','Cytology Screening and Histology Space',#557,$,$); -#567=IFCCLASSIFICATIONREFERENCE($,'13-51 47 29','Dermatology Laboratory',#557,$,$); -#568=IFCCLASSIFICATIONREFERENCE($,'13-51 47 31','Electron Microscope Suite',#557,$,$); -#569=IFCCLASSIFICATIONREFERENCE($,'13-51 47 33','Electron Microscope System Room',#557,$,$); -#570=IFCCLASSIFICATIONREFERENCE($,'13-51 47 35','Entomology Laboratory',#557,$,$); -#571=IFCCLASSIFICATIONREFERENCE($,'13-51 47 37','Flow Cytometer Space',#557,$,$); -#572=IFCCLASSIFICATIONREFERENCE($,'13-51 47 39','Fluorescence Microscope Room',#557,$,$); -#573=IFCCLASSIFICATIONREFERENCE($,'13-51 47 41','General Clinical Laboratory Area',#557,$,$); -#574=IFCCLASSIFICATIONREFERENCE($,'13-51 47 43','Hematology Laboratory, Coagulation',#557,$,$); -#575=IFCCLASSIFICATIONREFERENCE($,'13-51 47 45','Hematology Laboratory, Routine',#557,$,$); -#576=IFCCLASSIFICATIONREFERENCE($,'13-51 47 47','Histology Laboratory',#557,$,$); -#577=IFCCLASSIFICATIONREFERENCE($,'13-51 47 49','Immunopathology Laboratory',#557,$,$); -#578=IFCCLASSIFICATIONREFERENCE($,'13-51 47 51','Microbiology Biosafety Laboratory',#557,$,$); -#579=IFCCLASSIFICATIONREFERENCE($,'13-51 47 53','Microbiology Mycology Laboratory',#557,$,$); -#580=IFCCLASSIFICATIONREFERENCE($,'13-51 47 55','Microbiology Mycobacteriology Laboratory',#557,$,$); -#581=IFCCLASSIFICATIONREFERENCE($,'13-51 47 57','Moh''s Laboratory',#557,$,$); -#582=IFCCLASSIFICATIONREFERENCE($,'13-51 47 59','Mycology Laboratory',#557,$,$); -#583=IFCCLASSIFICATIONREFERENCE($,'13-51 47 61','Nephrology Renal Study Space',#557,$,$); -#584=IFCCLASSIFICATIONREFERENCE($,'13-51 47 63','Renal Studies Laboratory',#557,$,$); -#585=IFCCLASSIFICATIONREFERENCE($,'13-51 47 65','Special Chemistry Laboratory',#557,$,$); -#586=IFCCLASSIFICATIONREFERENCE($,'13-51 47 67','Urine Testing Alcove',#557,$,$); -#587=IFCCLASSIFICATIONREFERENCE($,'13-51 47 69','Urinalysis Laboratory',#557,$,$); -#588=IFCCLASSIFICATIONREFERENCE($,'13-51 47 71','Urology Laboratory',#557,$,$); -#589=IFCCLASSIFICATIONREFERENCE($,'13-51 47 73','Medical Autopsy Room',#557,$,$); -#590=IFCCLASSIFICATIONREFERENCE($,'13-51 51 00','Clinical Laboratory Support Spaces',#313,$,$); -#591=IFCCLASSIFICATIONREFERENCE($,'13-51 51 11','Blood Bank Donor Station',#590,$,$); -#592=IFCCLASSIFICATIONREFERENCE($,'13-51 51 13','Blood Bank Preparation Rom',#590,$,$); -#593=IFCCLASSIFICATIONREFERENCE($,'13-51 51 15','Blood Bank Blood Product Storage Space',#590,$,$); -#594=IFCCLASSIFICATIONREFERENCE($,'13-51 51 17','Blood Bank Storage and Transfusion Room',#590,$,$); -#595=IFCCLASSIFICATIONREFERENCE($,'13-51 51 19','Blood Specimen Collection Room',#590,$,$); -#596=IFCCLASSIFICATIONREFERENCE($,'13-51 51 21','Cell Bank Freezer, Ultra Low',#590,$,$); -#597=IFCCLASSIFICATIONREFERENCE($,'13-51 51 23','Electron Microscope Automated Data Processing Room',#590,$,$); -#598=IFCCLASSIFICATIONREFERENCE($,'13-51 51 25','Electron Microscope Cutting Room',#590,$,$); -#599=IFCCLASSIFICATIONREFERENCE($,'13-51 51 27','Electron Microscope Dark Room',#590,$,$); -#600=IFCCLASSIFICATIONREFERENCE($,'13-51 51 29','Electron Microscope Developing, Printing and Enlarging Room',#590,$,$); -#601=IFCCLASSIFICATIONREFERENCE($,'13-51 51 31','Electron Microscope Finishing Room',#590,$,$); -#602=IFCCLASSIFICATIONREFERENCE($,'13-51 51 33','Electron Microscope Preparation Room',#590,$,$); -#603=IFCCLASSIFICATIONREFERENCE($,'13-51 51 35','Glassware Washing and Decontamination Room, Clinical Laboratory',#590,$,$); -#604=IFCCLASSIFICATIONREFERENCE($,'13-51 51 37','Glassware Washing Room, Clinical Laboratory',#590,$,$); -#605=IFCCLASSIFICATIONREFERENCE($,'13-51 51 39','Slides and Blocks Storage Room, Clinical Laboratory',#590,$,$); -#606=IFCCLASSIFICATIONREFERENCE($,'13-51 51 41','Sterilization and Solution Preparation Room, Clinical Laboratory',#590,$,$); -#607=IFCCLASSIFICATIONREFERENCE($,'13-51 51 43','Tissue Storage Area, Clinical Laboratory',#590,$,$); -#608=IFCCLASSIFICATIONREFERENCE($,'13-51 51 45','Microbiology Media Preparation Laboratory',#590,$,$); -#609=IFCCLASSIFICATIONREFERENCE($,'13-51 51 47','Specimen Accessioning, Processing and Distribution Room',#590,$,$); -#610=IFCCLASSIFICATIONREFERENCE($,'13-51 51 49','Laboratory, Water',#590,$,$); -#611=IFCCLASSIFICATIONREFERENCE($,'13-51 54 00','Pharmacy Spaces',#313,$,$); -#612=IFCCLASSIFICATIONREFERENCE($,'13-51 54 11','Chemotherapy Agent Medication Preparation Room',#611,$,$); -#613=IFCCLASSIFICATIONREFERENCE($,'13-51 54 13','Compound Sterile Preparation Space - High Risk',#611,$,$); -#614=IFCCLASSIFICATIONREFERENCE($,'13-51 54 15','Compound Sterile Preparation Space - Low Risk',#611,$,$); -#615=IFCCLASSIFICATIONREFERENCE($,'13-51 54 17','Compounding Area',#611,$,$); -#616=IFCCLASSIFICATIONREFERENCE($,'13-51 54 19','Dialysate Preparation Room',#611,$,$); -#617=IFCCLASSIFICATIONREFERENCE($,'13-51 54 21','IV Admixture Anteroom',#611,$,$); -#618=IFCCLASSIFICATIONREFERENCE($,'13-51 54 23','IV Admixture Room',#611,$,$); -#619=IFCCLASSIFICATIONREFERENCE($,'13-51 54 25','Medication Preparation Room',#611,$,$); -#620=IFCCLASSIFICATIONREFERENCE($,'13-51 54 27','Methadone Dispensing Station',#611,$,$); -#621=IFCCLASSIFICATIONREFERENCE($,'13-51 54 29','Oncology Drug Preparation Area',#611,$,$); -#622=IFCCLASSIFICATIONREFERENCE($,'13-51 54 31','Pharmacy',#611,$,$); -#623=IFCCLASSIFICATIONREFERENCE($,'13-51 54 32','Pharmacy, Dispensing Space',#611,$,$); -#624=IFCCLASSIFICATIONREFERENCE($,'13-51 54 33','Pharmacy Manufacturing & Prepack Space',#611,$,$); -#625=IFCCLASSIFICATIONREFERENCE($,'13-51 54 35','Prescription Receiving Station',#611,$,$); -#626=IFCCLASSIFICATIONREFERENCE($,'13-51 54 37','Pharmacy, Bulk, Breakdown and Verification Area',#611,$,$); -#627=IFCCLASSIFICATIONREFERENCE($,'13-51 54 39','Pharmacy, Controlled Substances and Secured Dispensing',#611,$,$); -#628=IFCCLASSIFICATIONREFERENCE($,'13-51 57 00','Medical Services Logistic Spaces',#313,$,$); -#629=IFCCLASSIFICATIONREFERENCE($,'13-51 57 11','Automatic Cart Wash Area, Healthcare',#628,$,$); -#630=IFCCLASSIFICATIONREFERENCE($,'13-51 57 13','BSL3 Infectious Disease Suite, Autoclave Room',#628,$,$); -#631=IFCCLASSIFICATIONREFERENCE($,'13-51 57 15','BSL3 Suite, Autoclave Room',#628,$,$); -#632=IFCCLASSIFICATIONREFERENCE($,'13-51 57 17','Cart Assembly/Queue Area, Healthcare',#628,$,$); -#633=IFCCLASSIFICATIONREFERENCE($,'13-51 57 19','Clean Cart Holding Area, Healthcare',#628,$,$); -#634=IFCCLASSIFICATIONREFERENCE($,'13-51 57 20','Medical Material Cart Restocking Area',#628,$,$); -#635=IFCCLASSIFICATIONREFERENCE($,'13-51 57 21','Clean Linen Preparation and Storage Area, Healthcare',#628,$,$); -#636=IFCCLASSIFICATIONREFERENCE($,'13-51 57 23','Clean Supply Preparation and Assembly Area, Healthcare',#628,$,$); -#637=IFCCLASSIFICATIONREFERENCE($,'13-51 57 25','Clean Supply Preparation Area, Healthcare',#628,$,$); -#638=IFCCLASSIFICATIONREFERENCE($,'13-51 57 27','Equipment Processing and Clean Storage Room, Healthcare',#628,$,$); -#639=IFCCLASSIFICATIONREFERENCE($,'13-51 57 29','Ethylene Oxide Gas Sterilizer Room',#628,$,$); -#640=IFCCLASSIFICATIONREFERENCE($,'13-51 57 31','Instrument Sterilization Room',#628,$,$); -#641=IFCCLASSIFICATIONREFERENCE($,'13-51 57 32','Central Sterile, Receiving and Decontamination',#628,$,$); -#642=IFCCLASSIFICATIONREFERENCE($,'13-51 57 33','Manual Cart Wash Area, Healthcare',#628,$,$); -#643=IFCCLASSIFICATIONREFERENCE($,'13-51 57 35','Soiled Cart Holding Area, Healthcare',#628,$,$); -#644=IFCCLASSIFICATIONREFERENCE($,'13-51 57 37','Soiled Cart Receiving Area, Healthcare',#628,$,$); -#645=IFCCLASSIFICATIONREFERENCE($,'13-51 57 39','Soiled Instrument and Equipment Receiving and Decontamination Room, Healthcare',#628,$,$); -#646=IFCCLASSIFICATIONREFERENCE($,'13-51 57 41','Sterile Supply Preparation and Assembly Area, Healthcare',#628,$,$); -#647=IFCCLASSIFICATIONREFERENCE($,'13-51 57 43','Biomedical Electronic Repair',#628,$,$); -#648=IFCCLASSIFICATIONREFERENCE($,'13-51 61 00','Rehabilitation Spaces',#313,$,$); -#649=IFCCLASSIFICATIONREFERENCE($,'13-51 61 11','Amputee Training Area',#648,$,$); -#650=IFCCLASSIFICATIONREFERENCE($,'13-51 61 13','Brace Shop Fitting Shop',#648,$,$); -#651=IFCCLASSIFICATIONREFERENCE($,'13-51 61 15','Brace Shop , Adjustment/Modification Area',#648,$,$); -#652=IFCCLASSIFICATIONREFERENCE($,'13-51 61 17','Brace Shop Welding Area',#648,$,$); -#653=IFCCLASSIFICATIONREFERENCE($,'13-51 61 19','Computer Activities Room, Rehabilitation',#648,$,$); -#654=IFCCLASSIFICATIONREFERENCE($,'13-51 61 21','Prosthesis Design and Manufacturing Room, Rehabilitation',#648,$,$); -#655=IFCCLASSIFICATIONREFERENCE($,'13-51 61 23','Dynamic Alignment Room',#648,$,$); -#656=IFCCLASSIFICATIONREFERENCE($,'13-51 61 25','Therapeutic Exercise Spaces',#648,$,$); -#657=IFCCLASSIFICATIONREFERENCE($,'13-51 61 25 11','Therapeutic Exercise Area',#656,$,$); -#658=IFCCLASSIFICATIONREFERENCE($,'13-51 61 25 13','Exercise/Therapy Gymnasium',#656,$,$); -#659=IFCCLASSIFICATIONREFERENCE($,'13-51 61 25 15','Individual Therapeutic Exercise Area',#656,$,$); -#660=IFCCLASSIFICATIONREFERENCE($,'13-51 61 25 17','Treatment/Exercise Area',#656,$,$); -#661=IFCCLASSIFICATIONREFERENCE($,'13-51 61 27','Eye Fitting Studio',#648,$,$); -#662=IFCCLASSIFICATIONREFERENCE($,'13-51 61 29','Facial/Body Fitting Studio',#648,$,$); -#663=IFCCLASSIFICATIONREFERENCE($,'13-51 61 31','Fitting Room, Custom Fabrication',#648,$,$); -#664=IFCCLASSIFICATIONREFERENCE($,'13-51 61 33','Fitting Room, Soft Goods Fabrication',#648,$,$); -#665=IFCCLASSIFICATIONREFERENCE($,'13-51 61 35','Gait Lane',#648,$,$); -#666=IFCCLASSIFICATIONREFERENCE($,'13-51 61 37','Gait Study Track',#648,$,$); -#667=IFCCLASSIFICATIONREFERENCE($,'13-51 61 39','Hearing Aid Fabrication and Modification Room',#648,$,$); -#668=IFCCLASSIFICATIONREFERENCE($,'13-51 61 41','Hubbard Tank - Full Immersion',#648,$,$); -#669=IFCCLASSIFICATIONREFERENCE($,'13-51 61 43','Hubbard Tank - Partial Immersion',#648,$,$); -#670=IFCCLASSIFICATIONREFERENCE($,'13-51 61 45','Hydrotherapy Area',#648,$,$); -#671=IFCCLASSIFICATIONREFERENCE($,'13-51 61 47','Neurophysiology Rehabilitation Room',#648,$,$); -#672=IFCCLASSIFICATIONREFERENCE($,'13-51 61 49','Occupational Therapy Room',#648,$,$); -#673=IFCCLASSIFICATIONREFERENCE($,'13-51 61 50','Occupational Therapy, Daily Living Skills Training and Evaluation Room',#648,$,$); -#674=IFCCLASSIFICATIONREFERENCE($,'13-51 61 51','Pediatric Developmental Therapy Space',#648,$,$); -#675=IFCCLASSIFICATIONREFERENCE($,'13-51 61 53','Physical Therapy/Kinesiology Therapy Room',#648,$,$); -#676=IFCCLASSIFICATIONREFERENCE($,'13-51 61 55','Posturography Exam Room',#648,$,$); -#677=IFCCLASSIFICATIONREFERENCE($,'13-51 61 57','Prosthetic and Orthotic Dust Room',#648,$,$); -#678=IFCCLASSIFICATIONREFERENCE($,'13-51 61 59','Prosthetic and Orthotic Fume Room',#648,$,$); -#679=IFCCLASSIFICATIONREFERENCE($,'13-51 61 61','Prosthetic and Orthotic Work Station',#648,$,$); -#680=IFCCLASSIFICATIONREFERENCE($,'13-51 61 63','Prosthetic and Orthotic, Maintenance Support Room',#648,$,$); -#681=IFCCLASSIFICATIONREFERENCE($,'13-51 61 65','Rehabilitation Therapy Gym',#648,$,$); -#682=IFCCLASSIFICATIONREFERENCE($,'13-51 61 67','Speech Pathology Individual Therapy Room',#648,$,$); -#683=IFCCLASSIFICATIONREFERENCE($,'13-51 61 68','Speech Therapist, Exam and Treatment Space',#648,$,$); -#684=IFCCLASSIFICATIONREFERENCE($,'13-51 61 69','Therapeutic Pool',#648,$,$); -#685=IFCCLASSIFICATIONREFERENCE($,'13-51 61 71','Wheelchair Repair Workspace',#648,$,$); -#686=IFCCLASSIFICATIONREFERENCE($,'13-51 61 73','Whirlpool',#648,$,$); -#687=IFCCLASSIFICATIONREFERENCE($,'13-51 61 75','Rehabilitation Living Skills Training Apartment',#648,$,$); -#688=IFCCLASSIFICATIONREFERENCE($,'13-51 64 00','Dental Spaces',#313,$,$); -#689=IFCCLASSIFICATIONREFERENCE($,'13-51 64 11','Dental CS Suite',#688,$,$); -#690=IFCCLASSIFICATIONREFERENCE($,'13-51 64 13','Dental Hygiene and Operatory Room',#688,$,$); -#691=IFCCLASSIFICATIONREFERENCE($,'13-51 64 15','Dental Hygiene Room',#688,$,$); -#692=IFCCLASSIFICATIONREFERENCE($,'13-51 64 17','Dental Porcelain Room',#688,$,$); -#693=IFCCLASSIFICATIONREFERENCE($,'13-51 64 19','Dental Prosthetics Laboratory',#688,$,$); -#694=IFCCLASSIFICATIONREFERENCE($,'13-51 64 21','Dental Screening Room',#688,$,$); -#695=IFCCLASSIFICATIONREFERENCE($,'13-51 64 23','Dental Self Preparation Area',#688,$,$); -#696=IFCCLASSIFICATIONREFERENCE($,'13-51 64 25','Dental Treatment t Room, Mini Laboratory',#688,$,$); -#697=IFCCLASSIFICATIONREFERENCE($,'13-51 64 27','Dental Treatment Room',#688,$,$); -#698=IFCCLASSIFICATIONREFERENCE($,'13-51 64 29','Dental Treatment Room, Conscious Sedation Support',#688,$,$); -#699=IFCCLASSIFICATIONREFERENCE($,'13-51 64 31','Dental Treatment Room, Endodontics',#688,$,$); -#700=IFCCLASSIFICATIONREFERENCE($,'13-51 64 33','Dental Treatment Room, Orthodontics',#688,$,$); -#701=IFCCLASSIFICATIONREFERENCE($,'13-51 64 35','Dental Treatment Room, Pediatrics',#688,$,$); -#702=IFCCLASSIFICATIONREFERENCE($,'13-51 64 37','Dental Treatment Room, Periodontics',#688,$,$); -#703=IFCCLASSIFICATIONREFERENCE($,'13-51 64 39','Dental Treatment Room, Prosthodontics',#688,$,$); -#704=IFCCLASSIFICATIONREFERENCE($,'13-51 64 41','Dental X-Ray Room',#688,$,$); -#705=IFCCLASSIFICATIONREFERENCE($,'13-51 64 43','Instrument Preparation and Sterilization Room',#688,$,$); -#706=IFCCLASSIFICATIONREFERENCE($,'13-51 64 45','Maxillo-Facial Laboratory',#688,$,$); -#707=IFCCLASSIFICATIONREFERENCE($,'13-51 64 47','Maxillo-Facial Treatment Room',#688,$,$); -#708=IFCCLASSIFICATIONREFERENCE($,'13-51 64 49','Oral Pathology Laboratory',#688,$,$); -#709=IFCCLASSIFICATIONREFERENCE($,'13-51 64 51','Oral Surgery Residency Room',#688,$,$); -#710=IFCCLASSIFICATIONREFERENCE($,'13-51 64 53','Oral Surgery Room',#688,$,$); -#711=IFCCLASSIFICATIONREFERENCE($,'13-51 64 55','Panoramic Dental X-Ray Room',#688,$,$); -#712=IFCCLASSIFICATIONREFERENCE($,'13-51 64 57','Dental X-Ray Support Room',#688,$,$); -#713=IFCCLASSIFICATIONREFERENCE($,'13-51 67 00','Medical Research and Development Spaces',#313,$,$); -#714=IFCCLASSIFICATIONREFERENCE($,'13-51 67 11','Research Animal Recovery Area',#713,$,$); -#715=IFCCLASSIFICATIONREFERENCE($,'13-51 67 13','Barrier Suite, Procedure Laboratory',#713,$,$); -#716=IFCCLASSIFICATIONREFERENCE($,'13-51 67 15','Biomedical Research BSL3 Suite Tissue Culture Room',#713,$,$); -#717=IFCCLASSIFICATIONREFERENCE($,'13-51 67 17','Biomedical Research Tissue Culture Room',#713,$,$); -#718=IFCCLASSIFICATIONREFERENCE($,'13-51 67 18','Laboratory, Research, Biochemistry',#713,$,$); -#719=IFCCLASSIFICATIONREFERENCE($,'13-51 67 19','Biosafety Level 3 Laboratory',#713,$,$); -#720=IFCCLASSIFICATIONREFERENCE($,'13-51 67 21','BSL3 Infectious Disease Suite, Procedure Laboratory',#713,$,$); -#721=IFCCLASSIFICATIONREFERENCE($,'13-51 67 23','BSL3 Procedure Room',#713,$,$); -#722=IFCCLASSIFICATIONREFERENCE($,'13-51 67 25','Environmental Suite Infectious Disease Procedure Laboratory',#713,$,$); -#723=IFCCLASSIFICATIONREFERENCE($,'13-51 67 27','Research Infectious Disease Animal Holding Area',#713,$,$); -#724=IFCCLASSIFICATIONREFERENCE($,'13-51 67 29','Research Veterinary Radiography Control Room',#713,$,$); -#725=IFCCLASSIFICATIONREFERENCE($,'13-51 67 31','Research and Development Machine Shop',#713,$,$); -#726=IFCCLASSIFICATIONREFERENCE($,'13-51 67 33','Research Veterinary Radiography Procedure Room',#713,$,$); -#727=IFCCLASSIFICATIONREFERENCE($,'13-51 67 35','Research Diagnostic Laboratory',#713,$,$); -#728=IFCCLASSIFICATIONREFERENCE($,'13-51 67 37','Research NMR Room',#713,$,$); -#729=IFCCLASSIFICATIONREFERENCE($,'13-51 67 39','Research Procedure Laboratory',#713,$,$); -#730=IFCCLASSIFICATIONREFERENCE($,'13-51 67 41','Research Veterinary Surgical Suite, Animal Preparation Room',#713,$,$); -#731=IFCCLASSIFICATIONREFERENCE($,'13-51 67 43','Research Veterinary BSL3 Infectious Disease Suite Holding Room',#713,$,$); -#732=IFCCLASSIFICATIONREFERENCE($,'13-51 67 45','Research Veterinary Barrier Suite Holding Room',#713,$,$); -#733=IFCCLASSIFICATIONREFERENCE($,'13-51 67 47','Research Veterinary Chemical/Radioisotope Suite Holding Room',#713,$,$); -#734=IFCCLASSIFICATIONREFERENCE($,'13-51 67 49','Research Veterinary Environmental Suite Holding Room',#713,$,$); -#735=IFCCLASSIFICATIONREFERENCE($,'13-51 67 51','Research Veterinary Quarantine Holding Room',#713,$,$); -#736=IFCCLASSIFICATIONREFERENCE($,'13-51 67 53','Research Veterinary Surgery Room',#713,$,$); -#737=IFCCLASSIFICATIONREFERENCE($,'13-51 91 00','Veterinary Spaces',#313,$,$); -#738=IFCCLASSIFICATIONREFERENCE($,'13-51 91 11','Hospitalization Kennel',#737,$,$); -#739=IFCCLASSIFICATIONREFERENCE($,'13-51 91 14','Infectious Disease Animal Holding Area',#737,$,$); -#740=IFCCLASSIFICATIONREFERENCE($,'13-51 91 17','Veterinary Radiography Control Room',#737,$,$); -#741=IFCCLASSIFICATIONREFERENCE($,'13-51 91 20','Veterinary Radiography Procedure Room',#737,$,$); -#742=IFCCLASSIFICATIONREFERENCE($,'13-51 91 23','Veterinary Surgical Suite, Animal Preparation Room',#737,$,$); -#743=IFCCLASSIFICATIONREFERENCE($,'13-51 91 26','Veterinary BSL3 Infectious Disease Suite Holding Room',#737,$,$); -#744=IFCCLASSIFICATIONREFERENCE($,'13-51 91 29','Veterinary Barrier Suite Holding Room',#737,$,$); -#745=IFCCLASSIFICATIONREFERENCE($,'13-51 91 32','Veterinary Examination and Treatment Room',#737,$,$); -#746=IFCCLASSIFICATIONREFERENCE($,'13-51 91 35','Veterinary Quarantine Holding Room',#737,$,$); -#747=IFCCLASSIFICATIONREFERENCE($,'13-51 91 38','Veterinary Surgery Room',#737,$,$); -#748=IFCCLASSIFICATIONREFERENCE($,'13-51 91 41','Cage Wash Area',#737,$,$); -#749=IFCCLASSIFICATIONREFERENCE($,'13-51 91 44','Veterinary Food Preparation Room',#737,$,$); -#750=IFCCLASSIFICATIONREFERENCE($,'13-53 00 00','Laboratory Spaces',#2,$,$); -#751=IFCCLASSIFICATIONREFERENCE($,'13-53 11 00','Chemistry Laboratories',#750,$,$); -#752=IFCCLASSIFICATIONREFERENCE($,'13-53 13 00','Biosciences Laboratories',#750,$,$); -#753=IFCCLASSIFICATIONREFERENCE($,'13-53 15 00','Physical Sciences Laboratories',#750,$,$); -#754=IFCCLASSIFICATIONREFERENCE($,'13-53 15 11','Optical Physics Laboratory',#753,$,$); -#755=IFCCLASSIFICATIONREFERENCE($,'13-53 15 13','Physics Research Laboratory',#753,$,$); -#756=IFCCLASSIFICATIONREFERENCE($,'13-53 17 00','Astronomy Laboratories',#750,$,$); -#757=IFCCLASSIFICATIONREFERENCE($,'13-53 17 11','Astronomy Research Laboratory',#756,$,$); -#758=IFCCLASSIFICATIONREFERENCE($,'13-53 19 00','Earth and Environmental Sciences Laboratories',#750,$,$); -#759=IFCCLASSIFICATIONREFERENCE($,'13-53 19 11','Geology Laboratory',#758,$,$); -#760=IFCCLASSIFICATIONREFERENCE($,'13-53 19 13','Earth Sciences Research Laboratory',#758,$,$); -#761=IFCCLASSIFICATIONREFERENCE($,'13-53 21 00','Forensics Laboratories',#750,$,$); -#762=IFCCLASSIFICATIONREFERENCE($,'13-53 23 00','Psychology Laboratories',#750,$,$); -#763=IFCCLASSIFICATIONREFERENCE($,'13-53 25 00','Bench Laboratories',#750,$,$); -#764=IFCCLASSIFICATIONREFERENCE($,'13-53 27 00','Dry Laboratories',#750,$,$); -#765=IFCCLASSIFICATIONREFERENCE($,'13-53 29 00','Integration Laboratories',#750,$,$); -#766=IFCCLASSIFICATIONREFERENCE($,'13-53 31 00','Wet Laboratories',#750,$,$); -#767=IFCCLASSIFICATIONREFERENCE($,'13-53 33 00','Laboratory Storage Spaces',#750,$,$); -#768=IFCCLASSIFICATIONREFERENCE($,'13-53 35 00','Laboratory Support Spaces',#750,$,$); -#769=IFCCLASSIFICATIONREFERENCE($,'13-55 00 00','Commerce Activity Spaces',#2,$,$); -#770=IFCCLASSIFICATIONREFERENCE($,'13-55 11 00','Office Spaces',#769,$,$); -#771=IFCCLASSIFICATIONREFERENCE($,'13-55 11 11','Office Service',#770,$,$); -#772=IFCCLASSIFICATIONREFERENCE($,'13-55 11 13','Dedicated Enclosed Workstation',#770,$,$); -#773=IFCCLASSIFICATIONREFERENCE($,'13-55 11 15','Shared Enclosed Workstation',#770,$,$); -#774=IFCCLASSIFICATIONREFERENCE($,'13-55 11 17','Dedicated Open Workstation',#770,$,$); -#775=IFCCLASSIFICATIONREFERENCE($,'13-55 11 19','Shared Open Workstation',#770,$,$); -#776=IFCCLASSIFICATIONREFERENCE($,'13-55 11 21','Open Team Setting',#770,$,$); -#777=IFCCLASSIFICATIONREFERENCE($,'13-55 11 23','General File and Storage',#770,$,$); -#778=IFCCLASSIFICATIONREFERENCE($,'13-55 11 25','Shared Workstation File and Storage',#770,$,$); -#779=IFCCLASSIFICATIONREFERENCE($,'13-55 11 27','Shared Equipment Station',#770,$,$); -#780=IFCCLASSIFICATIONREFERENCE($,'13-55 11 29','Lookout Gallery',#770,$,$); -#781=IFCCLASSIFICATIONREFERENCE($,'13-55 13 00','Banking Spaces',#769,$,$); -#782=IFCCLASSIFICATIONREFERENCE($,'13-55 13 11','Bank Teller Space',#781,$,$); -#783=IFCCLASSIFICATIONREFERENCE($,'13-55 13 13','Automatic Teller Machine Space',#781,$,$); -#784=IFCCLASSIFICATIONREFERENCE($,'13-55 13 15','Vault',#781,$,$); -#785=IFCCLASSIFICATIONREFERENCE($,'13-55 15 00','Trading Spaces',#769,$,$); -#786=IFCCLASSIFICATIONREFERENCE($,'13-55 15 11','Trading Floor',#785,$,$); -#787=IFCCLASSIFICATIONREFERENCE($,'13-55 17 00','Demonstration Spaces',#769,$,$); -#788=IFCCLASSIFICATIONREFERENCE($,'13-55 19 00','Sales Spaces',#769,$,$); -#789=IFCCLASSIFICATIONREFERENCE($,'13-55 19 11','Checkout Space',#788,$,$); -#790=IFCCLASSIFICATIONREFERENCE($,'13-55 19 13','Display Space',#788,$,$); -#791=IFCCLASSIFICATIONREFERENCE($,'13-55 19 15','Fitting Space',#788,$,$); -#792=IFCCLASSIFICATIONREFERENCE($,'13-55 19 17','Vending Machine Area',#788,$,$); -#793=IFCCLASSIFICATIONREFERENCE($,'13-55 19 19','Auction Room',#788,$,$); -#794=IFCCLASSIFICATIONREFERENCE($,'13-55 19 21','Pet Shop Animal Space',#788,$,$); -#795=IFCCLASSIFICATIONREFERENCE($,'13-55 21 00','Commercial Service and Repair Spaces',#769,$,$); -#796=IFCCLASSIFICATIONREFERENCE($,'13-55 23 00','Commercial Support Spaces',#769,$,$); -#797=IFCCLASSIFICATIONREFERENCE($,'13-55 27 00','Hotel, Motel, Hostel, and Dormitory Service Spaces',#769,$,$); -#798=IFCCLASSIFICATIONREFERENCE($,'13-55 27 11','Dormitory',#797,$,$); -#799=IFCCLASSIFICATIONREFERENCE($,'13-55 27 13','Hotel Residence Room',#797,$,$); -#800=IFCCLASSIFICATIONREFERENCE($,'13-55 29 00','Commerce Activity Support Areas',#769,$,$); -#801=IFCCLASSIFICATIONREFERENCE($,'13-55 29 11','Information Counter',#800,$,$); -#802=IFCCLASSIFICATIONREFERENCE($,'13-55 29 13','Lobby Non-Circulation Space',#800,$,$); -#803=IFCCLASSIFICATIONREFERENCE($,'13-55 29 15','Post Office Space',#800,$,$); -#804=IFCCLASSIFICATIONREFERENCE($,'13-55 29 17','Mail Room Space',#800,$,$); -#805=IFCCLASSIFICATIONREFERENCE($,'13-55 29 19','Box Lobby',#800,$,$); -#806=IFCCLASSIFICATIONREFERENCE($,'13-55 29 21','Meeting Spaces',#800,$,$); -#807=IFCCLASSIFICATIONREFERENCE($,'13-55 29 21 11','Conference Room',#806,$,$); -#808=IFCCLASSIFICATIONREFERENCE($,'13-55 29 21 13','Press Conference Room',#806,$,$); -#809=IFCCLASSIFICATIONREFERENCE($,'13-55 29 21 15','Community Room',#806,$,$); -#810=IFCCLASSIFICATIONREFERENCE($,'13-55 29 21 17','War Room',#806,$,$); -#811=IFCCLASSIFICATIONREFERENCE($,'13-55 29 21 19','Meeting Equipment Room',#806,$,$); -#812=IFCCLASSIFICATIONREFERENCE($,'13-55 29 23','Waiting Space',#800,$,$); -#813=IFCCLASSIFICATIONREFERENCE($,'13-55 29 23 11','Reception Space',#812,$,$); -#814=IFCCLASSIFICATIONREFERENCE($,'13-55 29 23 13','Waiting Room',#812,$,$); -#815=IFCCLASSIFICATIONREFERENCE($,'13-55 29 23 15','Queuing Space',#812,$,$); -#816=IFCCLASSIFICATIONREFERENCE($,'13-55 29 25','Business Support Space',#800,$,$); -#817=IFCCLASSIFICATIONREFERENCE($,'13-57 00 00','Service Activity Spaces',#2,$,$); -#818=IFCCLASSIFICATIONREFERENCE($,'13-57 11 00','Grooming Activity Spaces',#817,$,$); -#819=IFCCLASSIFICATIONREFERENCE($,'13-57 11 11','Makeup Space',#818,$,$); -#820=IFCCLASSIFICATIONREFERENCE($,'13-57 11 13','Haircutting Space',#818,$,$); -#821=IFCCLASSIFICATIONREFERENCE($,'13-57 13 00','Food Service',#817,$,$); -#822=IFCCLASSIFICATIONREFERENCE($,'13-57 13 11','Cooking Spaces',#821,$,$); -#823=IFCCLASSIFICATIONREFERENCE($,'13-57 13 13','Kitchen Space',#821,$,$); -#824=IFCCLASSIFICATIONREFERENCE($,'13-57 13 13 11','Food Preparation Space',#823,$,$); -#825=IFCCLASSIFICATIONREFERENCE($,'13-57 13 13 13','Cooking Space',#823,$,$); -#826=IFCCLASSIFICATIONREFERENCE($,'13-57 13 13 15','Dishwashing Station',#823,$,$); -#827=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15','Dining and Drinking Spaces',#821,$,$); -#828=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15 11','Dining Room',#827,$,$); -#829=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15 13','Banquet Hall',#827,$,$); -#830=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15 15','Food Court',#827,$,$); -#831=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15 17','Snack Bar',#827,$,$); -#832=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15 19','Salad Bar',#827,$,$); -#833=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15 21','Liquor Bar',#827,$,$); -#834=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15 23','Beverage Station',#827,$,$); -#835=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15 25','Table Bussing Station',#827,$,$); -#836=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15 27','Serving Station',#827,$,$); -#837=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15 29','Vending Perishable Product Space',#827,$,$); -#838=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15 31','Cafeteria Vending Space',#827,$,$); -#839=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15 33','Tray Return Space',#827,$,$); -#840=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15 35','Food Discard Station',#827,$,$); -#841=IFCCLASSIFICATIONREFERENCE($,'13-57 13 17','Coffee stations',#821,$,$); -#842=IFCCLASSIFICATIONREFERENCE($,'13-57 15 00','Child Care Spaces',#817,$,$); -#843=IFCCLASSIFICATIONREFERENCE($,'13-57 15 11','Daycare sickroom',#842,$,$); -#844=IFCCLASSIFICATIONREFERENCE($,'13-57 15 13','Child Day Care Space',#842,$,$); -#845=IFCCLASSIFICATIONREFERENCE($,'13-57 15 15','Play Room',#842,$,$); -#846=IFCCLASSIFICATIONREFERENCE($,'13-57 15 17','CLD\X2\2013\X0\Child Care',#842,$,$); -#847=IFCCLASSIFICATIONREFERENCE($,'13-57 17 00','Resting Spaces',#817,$,$); -#848=IFCCLASSIFICATIONREFERENCE($,'13-57 17 11','Rest Area',#847,$,$); -#849=IFCCLASSIFICATIONREFERENCE($,'13-57 17 13','Break Room',#847,$,$); -#850=IFCCLASSIFICATIONREFERENCE($,'13-57 21 00','Laundry/Dry Cleaning Space',#817,$,$); -#851=IFCCLASSIFICATIONREFERENCE($,'13-57 23 00','Smoking Space',#817,$,$); -#852=IFCCLASSIFICATIONREFERENCE($,'13-59 00 00','Production, Fabrication, and Maintenance Spaces',#2,$,$); -#853=IFCCLASSIFICATIONREFERENCE($,'13-59 11 00','Material Handling Area',#852,$,$); -#854=IFCCLASSIFICATIONREFERENCE($,'13-59 13 00','Batching Space',#852,$,$); -#855=IFCCLASSIFICATIONREFERENCE($,'13-59 15 00','Production Process',#852,$,$); -#856=IFCCLASSIFICATIONREFERENCE($,'13-59 15 11','Workbench',#855,$,$); -#857=IFCCLASSIFICATIONREFERENCE($,'13-59 15 13','Mock-up Space',#855,$,$); -#858=IFCCLASSIFICATIONREFERENCE($,'13-59 17 00','Printing and Reproduction Spaces',#852,$,$); -#859=IFCCLASSIFICATIONREFERENCE($,'13-59 19 00','Quality Control and Test Spaces',#852,$,$); -#860=IFCCLASSIFICATIONREFERENCE($,'13-59 19 11','Product Inspection Space',#859,$,$); -#861=IFCCLASSIFICATIONREFERENCE($,'13-59 19 13','Production Observation Space',#859,$,$); -#862=IFCCLASSIFICATIONREFERENCE($,'13-59 21 00','Production Service and Repair Spaces',#852,$,$); -#863=IFCCLASSIFICATIONREFERENCE($,'13-59 23 00','Production and In-Process Storage Spaces',#852,$,$); -#864=IFCCLASSIFICATIONREFERENCE($,'13-59 25 00','Production Support Spaces',#852,$,$); -#865=IFCCLASSIFICATIONREFERENCE($,'13-59 29 00','Greenhouse Spaces',#852,$,$); -#866=IFCCLASSIFICATIONREFERENCE($,'13-59 29 11','Greenhouse Support Space',#865,$,$); -#867=IFCCLASSIFICATIONREFERENCE($,'13-61 00 00','Protective Spaces',#2,$,$); -#868=IFCCLASSIFICATIONREFERENCE($,'13-61 11 00','Animal Securing Spaces',#867,$,$); -#869=IFCCLASSIFICATIONREFERENCE($,'13-61 11 11','Cage',#868,$,$); -#870=IFCCLASSIFICATIONREFERENCE($,'13-61 11 13','Animal Stall',#868,$,$); -#871=IFCCLASSIFICATIONREFERENCE($,'13-61 11 15','Kennel',#868,$,$); -#872=IFCCLASSIFICATIONREFERENCE($,'13-61 11 17','Aquarium',#868,$,$); -#873=IFCCLASSIFICATIONREFERENCE($,'13-61 13 00','Detention Spaces',#867,$,$); -#874=IFCCLASSIFICATIONREFERENCE($,'13-61 13 11','Detention Cell',#873,$,$); -#875=IFCCLASSIFICATIONREFERENCE($,'13-61 13 13','Holding Cell',#873,$,$); -#876=IFCCLASSIFICATIONREFERENCE($,'13-61 13 15','Impound Lot',#873,$,$); -#877=IFCCLASSIFICATIONREFERENCE($,'13-61 13 17','Dayroom',#873,$,$); -#878=IFCCLASSIFICATIONREFERENCE($,'13-61 15 00','Spaces for Protection from the Elements',#867,$,$); -#879=IFCCLASSIFICATIONREFERENCE($,'13-61 15 11','Park Shelter',#878,$,$); -#880=IFCCLASSIFICATIONREFERENCE($,'13-61 15 13','Entry Porch',#878,$,$); -#881=IFCCLASSIFICATIONREFERENCE($,'13-61 15 15','Covered Walkway',#878,$,$); -#882=IFCCLASSIFICATIONREFERENCE($,'13-61 15 17','Canopy',#878,$,$); -#883=IFCCLASSIFICATIONREFERENCE($,'13-61 15 19','Shielded Room',#878,$,$); -#884=IFCCLASSIFICATIONREFERENCE($,'13-61 15 21','Containment Room',#878,$,$); -#885=IFCCLASSIFICATIONREFERENCE($,'13-61 17 00','Spaces for Protection from Violence',#867,$,$); -#886=IFCCLASSIFICATIONREFERENCE($,'13-61 17 11','Safe Room',#885,$,$); -#887=IFCCLASSIFICATIONREFERENCE($,'13-61 17 13','Bunker',#885,$,$); -#888=IFCCLASSIFICATIONREFERENCE($,'13-61 17 15','Bomb Shelter',#885,$,$); -#889=IFCCLASSIFICATIONREFERENCE($,'13-63 00 00','Storage Spaces',#2,$,$); -#890=IFCCLASSIFICATIONREFERENCE($,'13-63 11 00','Warehouse Spaces',#889,$,$); -#891=IFCCLASSIFICATIONREFERENCE($,'13-63 11 11','High Bay Warehouse Space',#890,$,$); -#892=IFCCLASSIFICATIONREFERENCE($,'13-63 11 13','General Warehouse Space',#890,$,$); -#893=IFCCLASSIFICATIONREFERENCE($,'13-63 11 15','Warehouse Support Space',#890,$,$); -#894=IFCCLASSIFICATIONREFERENCE($,'13-63 13 00','Non-Warehouse Storage Spaces',#889,$,$); -#895=IFCCLASSIFICATIONREFERENCE($,'13-63 13 11','Storage Room',#894,$,$); -#896=IFCCLASSIFICATIONREFERENCE($,'13-63 13 11 11','GNS\X2\2013\X0\General Storage',#895,$,$); -#897=IFCCLASSIFICATIONREFERENCE($,'13-63 13 13','Closet',#894,$,$); -#898=IFCCLASSIFICATIONREFERENCE($,'13-63 13 15','Coat Check',#894,$,$); -#899=IFCCLASSIFICATIONREFERENCE($,'13-63 13 17','Locker Room',#894,$,$); -#900=IFCCLASSIFICATIONREFERENCE($,'13-63 13 19','Filing Space',#894,$,$); -#901=IFCCLASSIFICATIONREFERENCE($,'13-63 13 21','Supply Room',#894,$,$); -#902=IFCCLASSIFICATIONREFERENCE($,'13-63 13 23','Unit Storage',#894,$,$); -#903=IFCCLASSIFICATIONREFERENCE($,'13-63 13 25','Consolidation/Containerization Point',#894,$,$); -#904=IFCCLASSIFICATIONREFERENCE($,'13-63 13 27','Self Storage Space',#894,$,$); -#905=IFCCLASSIFICATIONREFERENCE($,'13-63 13 29','Operational Storage (Misc)',#894,$,$); -#906=IFCCLASSIFICATIONREFERENCE($,'13-63 13 31','Operational Hazardous/Flammable Storage',#894,$,$); -#907=IFCCLASSIFICATIONREFERENCE($,'13-63 15 00','Moveable Storage Spaces',#889,$,$); -#908=IFCCLASSIFICATIONREFERENCE($,'13-63 15 11','Vehicle Storage Compartment',#907,$,$); -#909=IFCCLASSIFICATIONREFERENCE($,'13-63 15 13','Portable Bin',#907,$,$); -#910=IFCCLASSIFICATIONREFERENCE($,'13-63 15 15','Vessel Hold',#907,$,$); -#911=IFCCLASSIFICATIONREFERENCE($,'13-63 17 00','Environmentally Controlled Storage Spaces',#889,$,$); -#912=IFCCLASSIFICATIONREFERENCE($,'13-63 17 11','Refrigeration Compartment',#911,$,$); -#913=IFCCLASSIFICATIONREFERENCE($,'13-63 17 13','Freezing Compartment',#911,$,$); -#914=IFCCLASSIFICATIONREFERENCE($,'13-63 17 15','Humidity Controlled Storage Space',#911,$,$); -#915=IFCCLASSIFICATIONREFERENCE($,'13-63 17 17','Vacuum Sealed Storage Compartment',#911,$,$); -#916=IFCCLASSIFICATIONREFERENCE($,'13-63 19 00','Specialty Storage Spaces',#889,$,$); -#917=IFCCLASSIFICATIONREFERENCE($,'13-63 19 11','Sanitary Storage Room',#916,$,$); -#918=IFCCLASSIFICATIONREFERENCE($,'13-63 19 13','Soiled Storage Room Space',#916,$,$); -#919=IFCCLASSIFICATIONREFERENCE($,'13-63 19 15','Sacristy',#916,$,$); -#920=IFCCLASSIFICATIONREFERENCE($,'13-63 19 17','Vestry',#916,$,$); -#921=IFCCLASSIFICATIONREFERENCE($,'13-63 19 19','Hazardous Material Storage Space',#916,$,$); -#922=IFCCLASSIFICATIONREFERENCE($,'13-63 19 21','Book Stacks',#916,$,$); -#923=IFCCLASSIFICATIONREFERENCE($,'13-63 19 23','Baggage Claim',#916,$,$); -#924=IFCCLASSIFICATIONREFERENCE($,'13-63 19 25','Evidence Room',#916,$,$); -#925=IFCCLASSIFICATIONREFERENCE($,'13-63 19 27','Vehicle Impound Lot',#916,$,$); -#926=IFCCLASSIFICATIONREFERENCE($,'13-63 19 29','Operating Fuel Storage',#916,$,$); -#927=IFCCLASSIFICATIONREFERENCE($,'13-65 00 00','Private Residential Spaces',#2,$,$); -#928=IFCCLASSIFICATIONREFERENCE($,'13-65 11 00','On-call Room',#927,$,$); -#929=IFCCLASSIFICATIONREFERENCE($,'13-65 13 00','Bathroom',#927,$,$); -#930=IFCCLASSIFICATIONREFERENCE($,'13-65 13 11','Shower Space',#929,$,$); -#931=IFCCLASSIFICATIONREFERENCE($,'13-65 13 13','Toilet Space',#929,$,$); -#932=IFCCLASSIFICATIONREFERENCE($,'13-65 13 15','Ablution Room',#929,$,$); -#933=IFCCLASSIFICATIONREFERENCE($,'13-65 13 17','Combination Toilet and Bathing Space',#929,$,$); -#934=IFCCLASSIFICATIONREFERENCE($,'13-65 15 00','Mud Room',#927,$,$); -#935=IFCCLASSIFICATIONREFERENCE($,'13-65 17 00','Laundry Room',#927,$,$); -#936=IFCCLASSIFICATIONREFERENCE($,'13-65 19 00','Bedroom',#927,$,$); -#937=IFCCLASSIFICATIONREFERENCE($,'13-65 19 11','Mental Health Resident Bedroom',#936,$,$); -#938=IFCCLASSIFICATIONREFERENCE($,'13-65 19 13','Mental Health Resident Bedroom, Bariatric',#936,$,$); -#939=IFCCLASSIFICATIONREFERENCE($,'13-65 21 00','Nursery',#927,$,$); -#940=IFCCLASSIFICATIONREFERENCE($,'13-65 23 00','Kitchen',#927,$,$); -#941=IFCCLASSIFICATIONREFERENCE($,'13-67 00 00','Alternate Workplace',#2,$,$); -#942=IFCCLASSIFICATIONREFERENCE($,'13-67 11 00','Customer Site',#941,$,$); -#943=IFCCLASSIFICATIONREFERENCE($,'13-67 13 00','Home Office',#941,$,$); -#944=IFCCLASSIFICATIONREFERENCE($,'13-67 15 00','Rent-An-Office',#941,$,$); -#945=IFCCLASSIFICATIONREFERENCE($,'13-67 17 00','No Fixed Location',#941,$,$); -#946=IFCCLASSIFICATIONREFERENCE($,'13-67 19 00','Supplier Site',#941,$,$); -#947=IFCCLASSIFICATIONREFERENCE($,'13-69 00 00','Building Associated Spaces',#2,$,$); -#948=IFCCLASSIFICATIONREFERENCE($,'13-69 11 00','Roof',#947,$,$); -#949=IFCCLASSIFICATIONREFERENCE($,'13-69 13 00','Roof Terrace',#947,$,$); -#950=IFCCLASSIFICATIONREFERENCE($,'13-69 15 00','Penthouse',#947,$,$); -#951=IFCCLASSIFICATIONREFERENCE($,'13-69 17 00','Antenna Farm',#947,$,$); -#952=IFCCLASSIFICATIONREFERENCE($,'13-69 19 00','Heliport',#947,$,$); -#953=IFCCLASSIFICATIONREFERENCE($,'13-69 21 00','Balcony',#947,$,$); -#954=IFCCLASSIFICATIONREFERENCE($,'13-69 23 00','Deck',#947,$,$); -#955=IFCCLASSIFICATIONREFERENCE($,'13-69 25 00','Pedestrian Travel Spaces',#947,$,$); -#956=IFCCLASSIFICATIONREFERENCE($,'13-69 25 11','Sidewalk',#955,$,$); -#957=IFCCLASSIFICATIONREFERENCE($,'13-69 25 13','Pedestrian Way',#955,$,$); -#958=IFCCLASSIFICATIONREFERENCE($,'13-69 25 15','Pedestrian Bridge',#955,$,$); -#959=IFCCLASSIFICATIONREFERENCE($,'13-69 25 17','Footpath',#955,$,$); -#960=IFCCLASSIFICATIONREFERENCE($,'13-69 25 19','Trail',#955,$,$); -#961=IFCCLASSIFICATIONREFERENCE($,'13-69 25 21','Gangway',#955,$,$); -#962=IFCCLASSIFICATIONREFERENCE($,'Table 21 - Elements',$,#1,'Assigns category classification to building elements based on this OmniClass (edition 2012) specification.\X2\000A000A\X0\For example: use this rule to comply with\X2\000A\X0\- ''Concept Design BIM 2010'' MVD (GSA), which requires such classification for IfcElement, IfcTypeProduct (except IfcSpaceType) and IfcSystem entities.\X2\000A\X0\- ''FM Handover'' MVD (COBie), which requires such classification for IfcTypeProduct (except IfcSpaceType), IfcGroup and IfcSystem entities.\X2\000A000A\X0\''Apply'' creates a Classification Reference for selected IFC entity, using OmniClass-required attributes derived from the item that you choose in the following list.\X2\000A00090009\X0\',$); -#963=IFCCLASSIFICATIONREFERENCE($,'21-01 00 00','Substructure',#962,$,$); -#964=IFCCLASSIFICATIONREFERENCE($,'21-01 10','Foundations',#963,$,$); -#965=IFCCLASSIFICATIONREFERENCE($,'21-01 10 10','Standard Foundations',#964,$,$); -#966=IFCCLASSIFICATIONREFERENCE($,'21-01 10 10 10','Wall Foundations',#965,$,$); -#967=IFCCLASSIFICATIONREFERENCE($,'21-01 10 10 30','Column Foundations',#965,$,$); -#968=IFCCLASSIFICATIONREFERENCE($,'21-01 10 10 90','Standard Foundation Supplementary Components',#965,$,$); -#969=IFCCLASSIFICATIONREFERENCE($,'21-01 10 20','Special Foundations',#964,$,$); -#970=IFCCLASSIFICATIONREFERENCE($,'21-01 10 20 10','Driven Piles',#969,$,$); -#971=IFCCLASSIFICATIONREFERENCE($,'21-01 10 20 15','Bored Piles',#969,$,$); -#972=IFCCLASSIFICATIONREFERENCE($,'21-01 10 20 20','Caissons',#969,$,$); -#973=IFCCLASSIFICATIONREFERENCE($,'21-01 10 20 30','Special Foundation Walls',#969,$,$); -#974=IFCCLASSIFICATIONREFERENCE($,'21-01 10 20 40','Foundation Anchors',#969,$,$); -#975=IFCCLASSIFICATIONREFERENCE($,'21-01 10 20 50','Underpinning',#969,$,$); -#976=IFCCLASSIFICATIONREFERENCE($,'21-01 10 20 60','Raft Foundations',#969,$,$); -#977=IFCCLASSIFICATIONREFERENCE($,'21-01 10 20 70','Pile Caps',#969,$,$); -#978=IFCCLASSIFICATIONREFERENCE($,'21-01 10 20 80','Grade Beams',#969,$,$); -#979=IFCCLASSIFICATIONREFERENCE($,'21-01 20','Subgrade Enclosures',#963,$,$); -#980=IFCCLASSIFICATIONREFERENCE($,'21-01 20 10','Walls for Subgrade Enclosures',#979,$,$); -#981=IFCCLASSIFICATIONREFERENCE($,'21-01 20 10 10','Subgrade Enclosure Wall Construction',#980,$,$); -#982=IFCCLASSIFICATIONREFERENCE($,'21-01 20 10 20','Subgrade Enclosure Wall Interior Skin',#980,$,$); -#983=IFCCLASSIFICATIONREFERENCE($,'21-01 20 10 90','Subgrade Enclosure Wall Supplementary Components',#980,$,$); -#984=IFCCLASSIFICATIONREFERENCE($,'21-01 40','Slabs-On-Grade',#963,$,$); -#985=IFCCLASSIFICATIONREFERENCE($,'21-01 40 10','Standard Slabs-on-Grade',#984,$,$); -#986=IFCCLASSIFICATIONREFERENCE($,'21-01 40 20','Structural Slabs-on-Grade',#984,$,$); -#987=IFCCLASSIFICATIONREFERENCE($,'21-01 40 30','Slab Trenches',#984,$,$); -#988=IFCCLASSIFICATIONREFERENCE($,'21-01 40 40','Pits and Bases',#984,$,$); -#989=IFCCLASSIFICATIONREFERENCE($,'21-01 40 90','Slab-On-Grade Supplementary Components',#984,$,$); -#990=IFCCLASSIFICATIONREFERENCE($,'21-01 40 90 10','Perimeter Insulation',#989,$,$); -#991=IFCCLASSIFICATIONREFERENCE($,'21-01 40 90 20','Vapor Retarder',#989,$,$); -#992=IFCCLASSIFICATIONREFERENCE($,'21-01 40 90 30','Waterproofing',#989,$,$); -#993=IFCCLASSIFICATIONREFERENCE($,'21-01 40 90 50','Mud Slab',#989,$,$); -#994=IFCCLASSIFICATIONREFERENCE($,'21-01 40 90 60','Subbase Layer',#989,$,$); -#995=IFCCLASSIFICATIONREFERENCE($,'21-01 60','Water and Gas Mitigation',#963,$,$); -#996=IFCCLASSIFICATIONREFERENCE($,'21-01 60 10','Building Subdrainage',#995,$,$); -#997=IFCCLASSIFICATIONREFERENCE($,'21-01 60 10 10','Foundation Drainage',#996,$,$); -#998=IFCCLASSIFICATIONREFERENCE($,'21-01 60 10 20','Underslab Drainage',#996,$,$); -#999=IFCCLASSIFICATIONREFERENCE($,'21-01 60 20','Off-Gassing Mitigation',#995,$,$); -#1000=IFCCLASSIFICATIONREFERENCE($,'21-01 60 20 10','Radon Mitigation',#999,$,$); -#1001=IFCCLASSIFICATIONREFERENCE($,'21-01 60 20 50','Methane Mitigation',#999,$,$); -#1002=IFCCLASSIFICATIONREFERENCE($,'21-01 90','Substructure Related Activities',#963,$,$); -#1003=IFCCLASSIFICATIONREFERENCE($,'21-01 90 10','Substructure Excavation',#1002,$,$); -#1004=IFCCLASSIFICATIONREFERENCE($,'21-01 90 10 10','Backfill and Compaction',#1003,$,$); -#1005=IFCCLASSIFICATIONREFERENCE($,'21-01 90 20','Construction Dewatering',#1002,$,$); -#1006=IFCCLASSIFICATIONREFERENCE($,'21-01 90 30','Excavation Support',#1002,$,$); -#1007=IFCCLASSIFICATIONREFERENCE($,'21-01 90 30 10','Anchor Tiebacks',#1006,$,$); -#1008=IFCCLASSIFICATIONREFERENCE($,'21-01 90 30 20','Cofferdams',#1006,$,$); -#1009=IFCCLASSIFICATIONREFERENCE($,'21-01 90 30 40','Cribbing and Walers',#1006,$,$); -#1010=IFCCLASSIFICATIONREFERENCE($,'21-01 90 30 60','Ground Freezing',#1006,$,$); -#1011=IFCCLASSIFICATIONREFERENCE($,'21-01 90 30 70','Slurry Walls',#1006,$,$); -#1012=IFCCLASSIFICATIONREFERENCE($,'21-01 90 40','Soil Treatment',#1002,$,$); -#1013=IFCCLASSIFICATIONREFERENCE($,'21-02 00 00','Shell',#962,$,$); -#1014=IFCCLASSIFICATIONREFERENCE($,'21-02 10','Superstructure',#1013,$,$); -#1015=IFCCLASSIFICATIONREFERENCE($,'21-02 10 10','Floor Construction',#1014,$,$); -#1016=IFCCLASSIFICATIONREFERENCE($,'21-02 10 10 10','Floor Structural Frame',#1015,$,$); -#1017=IFCCLASSIFICATIONREFERENCE($,'21-02 10 10 20','Floor Decks, Slabs, and Toppings',#1015,$,$); -#1018=IFCCLASSIFICATIONREFERENCE($,'21-02 10 10 30','Balcony Floor Construction',#1015,$,$); -#1019=IFCCLASSIFICATIONREFERENCE($,'21-02 10 10 40','Mezzanine Floor Construction',#1015,$,$); -#1020=IFCCLASSIFICATIONREFERENCE($,'21-02 10 10 50','Ramps',#1015,$,$); -#1021=IFCCLASSIFICATIONREFERENCE($,'21-02 10 10 90','Floor Construction Supplementary Components',#1015,$,$); -#1022=IFCCLASSIFICATIONREFERENCE($,'21-02 10 20','Roof Construction',#1014,$,$); -#1023=IFCCLASSIFICATIONREFERENCE($,'21-02 10 20 10','Roof Structural Frame',#1022,$,$); -#1024=IFCCLASSIFICATIONREFERENCE($,'21-02 10 20 20','Roof Decks, Slabs, and Sheathing',#1022,$,$); -#1025=IFCCLASSIFICATIONREFERENCE($,'21-02 10 20 30','Canopy Construction',#1022,$,$); -#1026=IFCCLASSIFICATIONREFERENCE($,'21-02 10 20 90','Roof Construction Supplementary Components',#1022,$,$); -#1027=IFCCLASSIFICATIONREFERENCE($,'21-02 10 80','Stairs',#1014,$,$); -#1028=IFCCLASSIFICATIONREFERENCE($,'21-02 10 80 10','Stair Construction',#1027,$,$); -#1029=IFCCLASSIFICATIONREFERENCE($,'21-02 10 80 30','Stair Soffits',#1027,$,$); -#1030=IFCCLASSIFICATIONREFERENCE($,'21-02 10 80 50','Stair Railings',#1027,$,$); -#1031=IFCCLASSIFICATIONREFERENCE($,'21-02 10 80 60','Fire Escapes',#1027,$,$); -#1032=IFCCLASSIFICATIONREFERENCE($,'21-02 10 80 70','Metal Walkways',#1027,$,$); -#1033=IFCCLASSIFICATIONREFERENCE($,'21-02 10 80 80','Ladders',#1027,$,$); -#1034=IFCCLASSIFICATIONREFERENCE($,'21-02 20','Exterior Vertical Enclosures',#1013,$,$); -#1035=IFCCLASSIFICATIONREFERENCE($,'21-02 20 10','Exterior Walls',#1034,$,$); -#1036=IFCCLASSIFICATIONREFERENCE($,'21-02 20 10 10','Exterior Wall Veneer',#1035,$,$); -#1037=IFCCLASSIFICATIONREFERENCE($,'21-02 20 10 20','Exterior Wall Construction',#1035,$,$); -#1038=IFCCLASSIFICATIONREFERENCE($,'21-02 20 10 30','Exterior Wall Interior Skin',#1035,$,$); -#1039=IFCCLASSIFICATIONREFERENCE($,'21-02 20 10 40','Fabricated Exterior Wall Assemblies',#1035,$,$); -#1040=IFCCLASSIFICATIONREFERENCE($,'21-02 20 10 50','Parapets',#1035,$,$); -#1041=IFCCLASSIFICATIONREFERENCE($,'21-02 20 10 60','Equipment Screens',#1035,$,$); -#1042=IFCCLASSIFICATIONREFERENCE($,'21-02 20 10 80','Exterior Wall Supplementary Components',#1035,$,$); -#1043=IFCCLASSIFICATIONREFERENCE($,'21-02 20 10 90','Exterior Wall Opening Supplementary Components',#1035,$,$); -#1044=IFCCLASSIFICATIONREFERENCE($,'21-02 20 20','Exterior Windows',#1034,$,$); -#1045=IFCCLASSIFICATIONREFERENCE($,'21-02 20 20 10','Exterior Operating Windows',#1044,$,$); -#1046=IFCCLASSIFICATIONREFERENCE($,'21-02 20 20 20','Exterior Fixed Windows',#1044,$,$); -#1047=IFCCLASSIFICATIONREFERENCE($,'21-02 20 20 30','Exterior Window Wall',#1044,$,$); -#1048=IFCCLASSIFICATIONREFERENCE($,'21-02 20 20 50','Exterior Special Function Windows',#1044,$,$); -#1049=IFCCLASSIFICATIONREFERENCE($,'21-02 20 50','Exterior Doors and Grilles',#1034,$,$); -#1050=IFCCLASSIFICATIONREFERENCE($,'21-02 20 50 10','Exterior Entrance Doors',#1049,$,$); -#1051=IFCCLASSIFICATIONREFERENCE($,'21-02 20 50 20','Exterior Utility Doors',#1049,$,$); -#1052=IFCCLASSIFICATIONREFERENCE($,'21-02 20 50 30','Exterior Oversize Doors',#1049,$,$); -#1053=IFCCLASSIFICATIONREFERENCE($,'21-02 20 50 40','Exterior Special Function Doors',#1049,$,$); -#1054=IFCCLASSIFICATIONREFERENCE($,'21-02 20 50 60','Exterior Grilles',#1049,$,$); -#1055=IFCCLASSIFICATIONREFERENCE($,'21-02 20 50 70','Exterior Gates',#1049,$,$); -#1056=IFCCLASSIFICATIONREFERENCE($,'21-02 20 50 90','Exterior Door Supplementary Components',#1049,$,$); -#1057=IFCCLASSIFICATIONREFERENCE($,'21-02 20 70','Exterior Louvers and Vents',#1034,$,$); -#1058=IFCCLASSIFICATIONREFERENCE($,'21-02 20 70 10','Exterior Louvers',#1057,$,$); -#1059=IFCCLASSIFICATIONREFERENCE($,'21-02 20 70 50','Exterior Vents',#1057,$,$); -#1060=IFCCLASSIFICATIONREFERENCE($,'21-02 20 80','Exterior Wall Appurtenances',#1034,$,$); -#1061=IFCCLASSIFICATIONREFERENCE($,'21-02 20 80 10','Exterior Fixed Grilles and Screens',#1060,$,$); -#1062=IFCCLASSIFICATIONREFERENCE($,'21-02 20 80 30','Exterior Opening Protection Devices',#1060,$,$); -#1063=IFCCLASSIFICATIONREFERENCE($,'21-02 20 80 50','Exterior Balcony Walls and Railings',#1060,$,$); -#1064=IFCCLASSIFICATIONREFERENCE($,'21-02 20 80 70','Exterior Fabrications',#1060,$,$); -#1065=IFCCLASSIFICATIONREFERENCE($,'21-02 20 80 80','Bird Control Devices',#1060,$,$); -#1066=IFCCLASSIFICATIONREFERENCE($,'21-02 20 90','Exterior Wall Specialties',#1034,$,$); -#1067=IFCCLASSIFICATIONREFERENCE($,'21-02 30','Exterior Horizontal Enclosures',#1013,$,$); -#1068=IFCCLASSIFICATIONREFERENCE($,'21-02 30 10','Roofing',#1067,$,$); -#1069=IFCCLASSIFICATIONREFERENCE($,'21-02 30 10 10','Steep Slope Roofing',#1068,$,$); -#1070=IFCCLASSIFICATIONREFERENCE($,'21-02 30 10 50','Low-Slope Roofing',#1068,$,$); -#1071=IFCCLASSIFICATIONREFERENCE($,'21-02 30 10 70','Canopy Roofing',#1068,$,$); -#1072=IFCCLASSIFICATIONREFERENCE($,'21-02 30 10 90','Roofing Supplementary Components',#1068,$,$); -#1073=IFCCLASSIFICATIONREFERENCE($,'21-02 30 20','Roof Appurtenances',#1067,$,$); -#1074=IFCCLASSIFICATIONREFERENCE($,'21-02 30 20 10','Roof Accessories',#1073,$,$); -#1075=IFCCLASSIFICATIONREFERENCE($,'21-02 30 20 30','Roof Specialties',#1073,$,$); -#1076=IFCCLASSIFICATIONREFERENCE($,'21-02 30 20 70','Rainwater Management',#1073,$,$); -#1077=IFCCLASSIFICATIONREFERENCE($,'21-02 30 40','Traffic Bearing Horizontal Enclosures',#1067,$,$); -#1078=IFCCLASSIFICATIONREFERENCE($,'21-02 30 40 10','Traffic Bearing Coatings',#1077,$,$); -#1079=IFCCLASSIFICATIONREFERENCE($,'21-02 30 40 30','Horizontal Waterproofing Membrane',#1077,$,$); -#1080=IFCCLASSIFICATIONREFERENCE($,'21-02 30 40 50','Wear Surfaces',#1077,$,$); -#1081=IFCCLASSIFICATIONREFERENCE($,'21-02 30 40 90','Horizontal Enclosure Supplementary Components',#1077,$,$); -#1082=IFCCLASSIFICATIONREFERENCE($,'21-02 30 60','Horizontal Openings',#1067,$,$); -#1083=IFCCLASSIFICATIONREFERENCE($,'21-02 30 60 10','Roof Windows and Skylights',#1082,$,$); -#1084=IFCCLASSIFICATIONREFERENCE($,'21-02 30 60 50','Vents and Hatches',#1082,$,$); -#1085=IFCCLASSIFICATIONREFERENCE($,'21-02 30 60 90','Horizontal Opening Supplementary Components',#1082,$,$); -#1086=IFCCLASSIFICATIONREFERENCE($,'21-02 30 80','Overhead Exterior Enclosures',#1067,$,$); -#1087=IFCCLASSIFICATIONREFERENCE($,'21-02 30 80 10','Exterior Ceilings',#1086,$,$); -#1088=IFCCLASSIFICATIONREFERENCE($,'21-02 30 80 20','Exterior Soffits',#1086,$,$); -#1089=IFCCLASSIFICATIONREFERENCE($,'21-02 30 80 30','Exterior Bulkheads',#1086,$,$); -#1090=IFCCLASSIFICATIONREFERENCE($,'21-03 00 00','Interiors',#962,$,$); -#1091=IFCCLASSIFICATIONREFERENCE($,'21-03 10','Interior Construction',#1090,$,$); -#1092=IFCCLASSIFICATIONREFERENCE($,'21-03 10 10','Interior Partitions',#1091,$,$); -#1093=IFCCLASSIFICATIONREFERENCE($,'21-03 10 10 10','Interior Fixed Partitions',#1092,$,$); -#1094=IFCCLASSIFICATIONREFERENCE($,'21-03 10 10 20','Interior Glazed Partitions',#1092,$,$); -#1095=IFCCLASSIFICATIONREFERENCE($,'21-03 10 10 40','Interior Demountable Partitions',#1092,$,$); -#1096=IFCCLASSIFICATIONREFERENCE($,'21-03 10 10 50','Interior Operable Partitions',#1092,$,$); -#1097=IFCCLASSIFICATIONREFERENCE($,'21-03 10 10 70','Interior Screens',#1092,$,$); -#1098=IFCCLASSIFICATIONREFERENCE($,'21-03 10 10 90','Interior Partition Supplementary Components',#1092,$,$); -#1099=IFCCLASSIFICATIONREFERENCE($,'21-03 10 20','Interior Windows',#1091,$,$); -#1100=IFCCLASSIFICATIONREFERENCE($,'21-03 10 20 10','Interior Operating Windows',#1099,$,$); -#1101=IFCCLASSIFICATIONREFERENCE($,'21-03 10 20 20','Interior Fixed Windows',#1099,$,$); -#1102=IFCCLASSIFICATIONREFERENCE($,'21-03 10 20 50','Interior Special Function Windows',#1099,$,$); -#1103=IFCCLASSIFICATIONREFERENCE($,'21-03 10 20 90','Interior Window Supplementary Components',#1099,$,$); -#1104=IFCCLASSIFICATIONREFERENCE($,'21-03 10 30','Interior Doors',#1091,$,$); -#1105=IFCCLASSIFICATIONREFERENCE($,'21-03 10 30 10','Interior Swinging Doors',#1104,$,$); -#1106=IFCCLASSIFICATIONREFERENCE($,'21-03 10 30 20','Interior Entrance Doors',#1104,$,$); -#1107=IFCCLASSIFICATIONREFERENCE($,'21-03 10 30 25','Interior Sliding Doors',#1104,$,$); -#1108=IFCCLASSIFICATIONREFERENCE($,'21-03 10 30 30','Interior Folding Doors',#1104,$,$); -#1109=IFCCLASSIFICATIONREFERENCE($,'21-03 10 30 40','Interior Coiling Doors',#1104,$,$); -#1110=IFCCLASSIFICATIONREFERENCE($,'21-03 10 30 50','Interior Panel Doors',#1104,$,$); -#1111=IFCCLASSIFICATIONREFERENCE($,'21-03 10 30 70','Interior Special Function Doors',#1104,$,$); -#1112=IFCCLASSIFICATIONREFERENCE($,'21-03 10 30 80','Interior Access Doors and Panels',#1104,$,$); -#1113=IFCCLASSIFICATIONREFERENCE($,'21-03 10 30 90','Interior Door Supplementary Components',#1104,$,$); -#1114=IFCCLASSIFICATIONREFERENCE($,'21-03 10 40','Interior Grilles and Gates',#1091,$,$); -#1115=IFCCLASSIFICATIONREFERENCE($,'21-03 10 40 10','Interior Grilles',#1114,$,$); -#1116=IFCCLASSIFICATIONREFERENCE($,'21-03 10 40 50','Interior Gates',#1114,$,$); -#1117=IFCCLASSIFICATIONREFERENCE($,'21-03 10 60','Raised Floor Construction',#1091,$,$); -#1118=IFCCLASSIFICATIONREFERENCE($,'21-03 10 60 10','Access Flooring',#1117,$,$); -#1119=IFCCLASSIFICATIONREFERENCE($,'21-03 10 60 30','Platform/Stage Floors',#1117,$,$); -#1120=IFCCLASSIFICATIONREFERENCE($,'21-03 10 70','Suspended Ceiling Construction',#1091,$,$); -#1121=IFCCLASSIFICATIONREFERENCE($,'21-03 10 70 10','Acoustical Suspended Ceilings',#1120,$,$); -#1122=IFCCLASSIFICATIONREFERENCE($,'21-03 10 70 20','Suspended Plaster and Gypsum Board Ceilings',#1120,$,$); -#1123=IFCCLASSIFICATIONREFERENCE($,'21-03 10 70 50','Specialty Suspended Ceilings',#1120,$,$); -#1124=IFCCLASSIFICATIONREFERENCE($,'21-03 10 70 70','Special Function Suspended Ceilings',#1120,$,$); -#1125=IFCCLASSIFICATIONREFERENCE($,'21-03 10 70 90','Ceiling Suspension Components',#1120,$,$); -#1126=IFCCLASSIFICATIONREFERENCE($,'21-03 10 90','Interior Specialties',#1091,$,$); -#1127=IFCCLASSIFICATIONREFERENCE($,'21-03 10 90 10','Interior Railings and Handrails',#1126,$,$); -#1128=IFCCLASSIFICATIONREFERENCE($,'21-03 10 90 15','Interior Louvers',#1126,$,$); -#1129=IFCCLASSIFICATIONREFERENCE($,'21-03 10 90 20','Information Specialties',#1126,$,$); -#1130=IFCCLASSIFICATIONREFERENCE($,'21-03 10 90 25','Compartments and Cubicles',#1126,$,$); -#1131=IFCCLASSIFICATIONREFERENCE($,'21-03 10 90 30','Service Walls',#1126,$,$); -#1132=IFCCLASSIFICATIONREFERENCE($,'21-03 10 90 35','Wall and Door Protection',#1126,$,$); -#1133=IFCCLASSIFICATIONREFERENCE($,'21-03 10 90 40','Toilet, Bath, and Laundry Accessories',#1126,$,$); -#1134=IFCCLASSIFICATIONREFERENCE($,'21-03 10 90 45','Interior Gas Lighting',#1126,$,$); -#1135=IFCCLASSIFICATIONREFERENCE($,'21-03 10 90 50','Fireplaces and Stoves',#1126,$,$); -#1136=IFCCLASSIFICATIONREFERENCE($,'21-03 10 90 60','Safety Specialties',#1126,$,$); -#1137=IFCCLASSIFICATIONREFERENCE($,'21-03 10 90 70','Storage Specialties',#1126,$,$); -#1138=IFCCLASSIFICATIONREFERENCE($,'21-03 10 90 90','Other Interior Specialties',#1126,$,$); -#1139=IFCCLASSIFICATIONREFERENCE($,'21-03 20','Interior Finishes',#1090,$,$); -#1140=IFCCLASSIFICATIONREFERENCE($,'21-03 20 10','Wall Finishes',#1139,$,$); -#1141=IFCCLASSIFICATIONREFERENCE($,'21-03 20 10 10','Tile Wall Finish',#1140,$,$); -#1142=IFCCLASSIFICATIONREFERENCE($,'21-03 20 10 20','Wall Paneling',#1140,$,$); -#1143=IFCCLASSIFICATIONREFERENCE($,'21-03 20 10 30','Wall Coverings',#1140,$,$); -#1144=IFCCLASSIFICATIONREFERENCE($,'21-03 20 10 35','Wall Carpeting',#1140,$,$); -#1145=IFCCLASSIFICATIONREFERENCE($,'21-03 20 10 50','Stone Facing',#1140,$,$); -#1146=IFCCLASSIFICATIONREFERENCE($,'21-03 20 10 60','Special Wall Surfacing',#1140,$,$); -#1147=IFCCLASSIFICATIONREFERENCE($,'21-03 20 10 70','Wall Painting and Coating',#1140,$,$); -#1148=IFCCLASSIFICATIONREFERENCE($,'21-03 20 10 80','Acoustical Wall Treatment',#1140,$,$); -#1149=IFCCLASSIFICATIONREFERENCE($,'21-03 20 10 90','Wall Finish Supplementary Components',#1140,$,$); -#1150=IFCCLASSIFICATIONREFERENCE($,'21-03 20 20','Interior Fabrications',#1139,$,$); -#1151=IFCCLASSIFICATIONREFERENCE($,'21-03 20 30','Flooring',#1139,$,$); -#1152=IFCCLASSIFICATIONREFERENCE($,'21-03 20 30 10','Flooring Treatment',#1151,$,$); -#1153=IFCCLASSIFICATIONREFERENCE($,'21-03 20 30 20','Tile Flooring',#1151,$,$); -#1154=IFCCLASSIFICATIONREFERENCE($,'21-03 20 30 30','Specialty Flooring',#1151,$,$); -#1155=IFCCLASSIFICATIONREFERENCE($,'21-03 20 30 40','Masonry Flooring',#1151,$,$); -#1156=IFCCLASSIFICATIONREFERENCE($,'21-03 20 30 45','Wood Flooring',#1151,$,$); -#1157=IFCCLASSIFICATIONREFERENCE($,'21-03 20 30 50','Resilient Flooring',#1151,$,$); -#1158=IFCCLASSIFICATIONREFERENCE($,'21-03 20 30 60','Terrazzo Flooring',#1151,$,$); -#1159=IFCCLASSIFICATIONREFERENCE($,'21-03 20 30 70','Fluid-Applied Flooring',#1151,$,$); -#1160=IFCCLASSIFICATIONREFERENCE($,'21-03 20 30 75','Carpeting',#1151,$,$); -#1161=IFCCLASSIFICATIONREFERENCE($,'21-03 20 30 80','Athletic Flooring',#1151,$,$); -#1162=IFCCLASSIFICATIONREFERENCE($,'21-03 20 30 85','Entrance Flooring',#1151,$,$); -#1163=IFCCLASSIFICATIONREFERENCE($,'21-03 20 30 90','Flooring Supplementary Components',#1151,$,$); -#1164=IFCCLASSIFICATIONREFERENCE($,'21-03 20 40','Stair Finishes',#1139,$,$); -#1165=IFCCLASSIFICATIONREFERENCE($,'21-03 20 40 20','Tile Stair Finish',#1164,$,$); -#1166=IFCCLASSIFICATIONREFERENCE($,'21-03 20 40 40','Masonry Stair Finish',#1164,$,$); -#1167=IFCCLASSIFICATIONREFERENCE($,'21-03 20 40 45','Wood Stair Finish',#1164,$,$); -#1168=IFCCLASSIFICATIONREFERENCE($,'21-03 20 40 50','Resilient Stair Finish',#1164,$,$); -#1169=IFCCLASSIFICATIONREFERENCE($,'21-03 20 40 60','Terrazzo Stair Finish',#1164,$,$); -#1170=IFCCLASSIFICATIONREFERENCE($,'21-03 20 40 75','Carpeted Stair Finish',#1164,$,$); -#1171=IFCCLASSIFICATIONREFERENCE($,'21-03 20 50','Ceiling Finishes',#1139,$,$); -#1172=IFCCLASSIFICATIONREFERENCE($,'21-03 20 50 10','Plaster and Gypsum Board Finish',#1171,$,$); -#1173=IFCCLASSIFICATIONREFERENCE($,'21-03 20 50 20','Ceiling Paneling',#1171,$,$); -#1174=IFCCLASSIFICATIONREFERENCE($,'21-03 20 50 70','Ceiling Painting and Coating',#1171,$,$); -#1175=IFCCLASSIFICATIONREFERENCE($,'21-03 20 50 80','Acoustical Ceiling Treatment',#1171,$,$); -#1176=IFCCLASSIFICATIONREFERENCE($,'21-03 20 50 90','Ceiling Finish Supplementary Components',#1171,$,$); -#1177=IFCCLASSIFICATIONREFERENCE($,'21-04 00 00','Services',#962,$,$); -#1178=IFCCLASSIFICATIONREFERENCE($,'21-04 10','Conveying',#1177,$,$); -#1179=IFCCLASSIFICATIONREFERENCE($,'21-04 10 10','Vertical Conveying Systems',#1178,$,$); -#1180=IFCCLASSIFICATIONREFERENCE($,'21-04 10 10 10','Elevators',#1179,$,$); -#1181=IFCCLASSIFICATIONREFERENCE($,'21-04 10 10 20','Lifts',#1179,$,$); -#1182=IFCCLASSIFICATIONREFERENCE($,'21-04 10 10 30','Escalators',#1179,$,$); -#1183=IFCCLASSIFICATIONREFERENCE($,'21-04 10 10 50','Dumbwaiters',#1179,$,$); -#1184=IFCCLASSIFICATIONREFERENCE($,'21-04 10 10 60','Moving Ramps',#1179,$,$); -#1185=IFCCLASSIFICATIONREFERENCE($,'21-04 10 30','Horizontal Conveying',#1178,$,$); -#1186=IFCCLASSIFICATIONREFERENCE($,'21-04 10 30 10','Moving Walks',#1185,$,$); -#1187=IFCCLASSIFICATIONREFERENCE($,'21-04 10 30 30','Turntables',#1185,$,$); -#1188=IFCCLASSIFICATIONREFERENCE($,'21-04 10 30 50','Passenger Loading Bridges',#1185,$,$); -#1189=IFCCLASSIFICATIONREFERENCE($,'21-04 10 30 70','People Movers',#1185,$,$); -#1190=IFCCLASSIFICATIONREFERENCE($,'21-04 10 50','Material Handling',#1178,$,$); -#1191=IFCCLASSIFICATIONREFERENCE($,'21-04 10 50 10','Cranes',#1190,$,$); -#1192=IFCCLASSIFICATIONREFERENCE($,'21-04 10 50 20','Hoists',#1190,$,$); -#1193=IFCCLASSIFICATIONREFERENCE($,'21-04 10 50 30','Derricks',#1190,$,$); -#1194=IFCCLASSIFICATIONREFERENCE($,'21-04 10 50 40','Conveyors',#1190,$,$); -#1195=IFCCLASSIFICATIONREFERENCE($,'21-04 10 50 50','Baggage Handling Equipment',#1190,$,$); -#1196=IFCCLASSIFICATIONREFERENCE($,'21-04 10 50 60','Chutes',#1190,$,$); -#1197=IFCCLASSIFICATIONREFERENCE($,'21-04 10 50 70','Pneumatic Tube Systems',#1190,$,$); -#1198=IFCCLASSIFICATIONREFERENCE($,'21-04 10 80','Operable Access Systems',#1178,$,$); -#1199=IFCCLASSIFICATIONREFERENCE($,'21-04 10 80 10','Suspended Scaffolding',#1198,$,$); -#1200=IFCCLASSIFICATIONREFERENCE($,'21-04 10 80 20','Rope Climbers',#1198,$,$); -#1201=IFCCLASSIFICATIONREFERENCE($,'21-04 10 80 30','Elevating Platforms',#1198,$,$); -#1202=IFCCLASSIFICATIONREFERENCE($,'21-04 10 80 40','Powered Scaffolding',#1198,$,$); -#1203=IFCCLASSIFICATIONREFERENCE($,'21-04 10 80 50','Building Envelope Access',#1198,$,$); -#1204=IFCCLASSIFICATIONREFERENCE($,'21-04 20','Plumbing',#1177,$,$); -#1205=IFCCLASSIFICATIONREFERENCE($,'21-04 20 10','Domestic Water Distribution',#1204,$,$); -#1206=IFCCLASSIFICATIONREFERENCE($,'21-04 20 10 10','Facility Potable-Water Storage Tanks',#1205,$,$); -#1207=IFCCLASSIFICATIONREFERENCE($,'21-04 20 10 20','Domestic Water Equipment',#1205,$,$); -#1208=IFCCLASSIFICATIONREFERENCE($,'21-04 20 10 40','Domestic Water Piping',#1205,$,$); -#1209=IFCCLASSIFICATIONREFERENCE($,'21-04 20 10 60','Plumbing Fixtures',#1205,$,$); -#1210=IFCCLASSIFICATIONREFERENCE($,'21-04 20 10 90','Domestic Water Distribution Supplementary Components',#1205,$,$); -#1211=IFCCLASSIFICATIONREFERENCE($,'21-04 20 20','Sanitary Drainage',#1204,$,$); -#1212=IFCCLASSIFICATIONREFERENCE($,'21-04 20 20 10','Sanitary Sewerage Equipment',#1211,$,$); -#1213=IFCCLASSIFICATIONREFERENCE($,'21-04 20 20 30','Sanitary Sewerage Piping',#1211,$,$); -#1214=IFCCLASSIFICATIONREFERENCE($,'21-04 20 20 90','Sanitary Drainage Supplementary Components',#1211,$,$); -#1215=IFCCLASSIFICATIONREFERENCE($,'21-04 20 30','Building Support Plumbing Systems',#1204,$,$); -#1216=IFCCLASSIFICATIONREFERENCE($,'21-04 20 30 10','Stormwater Drainage Equipment',#1215,$,$); -#1217=IFCCLASSIFICATIONREFERENCE($,'21-04 20 30 20','Stormwater Drainage Piping',#1215,$,$); -#1218=IFCCLASSIFICATIONREFERENCE($,'21-04 20 30 30','Facility Stormwater Drains',#1215,$,$); -#1219=IFCCLASSIFICATIONREFERENCE($,'21-04 20 30 60','Gray Water Systems',#1215,$,$); -#1220=IFCCLASSIFICATIONREFERENCE($,'21-04 20 30 90','Building Support Plumbing System Supplementary Components',#1215,$,$); -#1221=IFCCLASSIFICATIONREFERENCE($,'21-04 20 50','General Service Compressed-Air',#1204,$,$); -#1222=IFCCLASSIFICATIONREFERENCE($,'21-04 20 60','Process Support Plumbing Systems',#1204,$,$); -#1223=IFCCLASSIFICATIONREFERENCE($,'21-04 20 60 10','Compressed-Air Systems',#1222,$,$); -#1224=IFCCLASSIFICATIONREFERENCE($,'21-04 20 60 20','Vacuum Systems',#1222,$,$); -#1225=IFCCLASSIFICATIONREFERENCE($,'21-04 20 60 30','Gas Systems',#1222,$,$); -#1226=IFCCLASSIFICATIONREFERENCE($,'21-04 20 60 40','Chemical-Waste Systems',#1222,$,$); -#1227=IFCCLASSIFICATIONREFERENCE($,'21-04 20 60 50','Processed Water Systems',#1222,$,$); -#1228=IFCCLASSIFICATIONREFERENCE($,'21-04 20 60 90','Process Support Plumbing System Supplementary Components',#1222,$,$); -#1229=IFCCLASSIFICATIONREFERENCE($,'21-04 30','Heating, Ventilation, and Air Conditioning (HVAC)',#1177,$,$); -#1230=IFCCLASSIFICATIONREFERENCE($,'21-04 30 10','Facility Fuel Systems',#1229,$,$); -#1231=IFCCLASSIFICATIONREFERENCE($,'21-04 30 10 10','Fuel Piping',#1230,$,$); -#1232=IFCCLASSIFICATIONREFERENCE($,'21-04 30 10 30','Fuel Pumps',#1230,$,$); -#1233=IFCCLASSIFICATIONREFERENCE($,'21-04 30 10 50','Fuel Storage Tanks',#1230,$,$); -#1234=IFCCLASSIFICATIONREFERENCE($,'21-04 30 20','Heating Systems',#1229,$,$); -#1235=IFCCLASSIFICATIONREFERENCE($,'21-04 30 20 10','Heat Generation',#1234,$,$); -#1236=IFCCLASSIFICATIONREFERENCE($,'21-04 30 20 30','Thermal Heat Storage',#1234,$,$); -#1237=IFCCLASSIFICATIONREFERENCE($,'21-04 30 20 70','Decentralized Heating Equipment',#1234,$,$); -#1238=IFCCLASSIFICATIONREFERENCE($,'21-04 30 20 90','Heating System Supplementary Components',#1234,$,$); -#1239=IFCCLASSIFICATIONREFERENCE($,'21-04 30 30','Cooling Systems',#1229,$,$); -#1240=IFCCLASSIFICATIONREFERENCE($,'21-04 30 30 10','Central Cooling',#1239,$,$); -#1241=IFCCLASSIFICATIONREFERENCE($,'21-04 30 30 30','Evaporative Air-Cooling',#1239,$,$); -#1242=IFCCLASSIFICATIONREFERENCE($,'21-04 30 30 50','Thermal Cooling Storage',#1239,$,$); -#1243=IFCCLASSIFICATIONREFERENCE($,'21-04 30 30 70','Decentralized Cooling',#1239,$,$); -#1244=IFCCLASSIFICATIONREFERENCE($,'21-04 30 30 90','Cooling System Supplementary Components',#1239,$,$); -#1245=IFCCLASSIFICATIONREFERENCE($,'21-04 30 50','Facility HVAC Distribution Systems',#1229,$,$); -#1246=IFCCLASSIFICATIONREFERENCE($,'21-04 30 50 10','Facility Hydronic Distribution',#1245,$,$); -#1247=IFCCLASSIFICATIONREFERENCE($,'21-04 30 50 30','Facility Steam Distribution',#1245,$,$); -#1248=IFCCLASSIFICATIONREFERENCE($,'21-04 30 50 50','HVAC Air Distribution',#1245,$,$); -#1249=IFCCLASSIFICATIONREFERENCE($,'21-04 30 50 90','Facility Distribution Systems Supplementary Components',#1245,$,$); -#1250=IFCCLASSIFICATIONREFERENCE($,'21-04 30 60','Ventilation',#1229,$,$); -#1251=IFCCLASSIFICATIONREFERENCE($,'21-04 30 60 10','Supply Air',#1250,$,$); -#1252=IFCCLASSIFICATIONREFERENCE($,'21-04 30 60 20','Return Air',#1250,$,$); -#1253=IFCCLASSIFICATIONREFERENCE($,'21-04 30 60 30','Exhaust Air',#1250,$,$); -#1254=IFCCLASSIFICATIONREFERENCE($,'21-04 30 60 40','Outside Air',#1250,$,$); -#1255=IFCCLASSIFICATIONREFERENCE($,'21-04 30 60 60','Air-to-Air Energy Recovery',#1250,$,$); -#1256=IFCCLASSIFICATIONREFERENCE($,'21-04 30 60 70','HVAC Air Cleaning',#1250,$,$); -#1257=IFCCLASSIFICATIONREFERENCE($,'21-04 30 60 90','Ventilation Supplementary Components',#1250,$,$); -#1258=IFCCLASSIFICATIONREFERENCE($,'21-04 30 70','Special Purpose HVAC Systems',#1229,$,$); -#1259=IFCCLASSIFICATIONREFERENCE($,'21-04 30 70 10','Snow Melting',#1258,$,$); -#1260=IFCCLASSIFICATIONREFERENCE($,'21-04 40','Fire Protection',#1177,$,$); -#1261=IFCCLASSIFICATIONREFERENCE($,'21-04 40 10','Fire Suppression',#1260,$,$); -#1262=IFCCLASSIFICATIONREFERENCE($,'21-04 40 10 10','Water-Based Fire-Suppression',#1261,$,$); -#1263=IFCCLASSIFICATIONREFERENCE($,'21-04 40 10 50','Fire-Extinguishing',#1261,$,$); -#1264=IFCCLASSIFICATIONREFERENCE($,'21-04 40 10 90','Fire Suppression Supplementary Components',#1261,$,$); -#1265=IFCCLASSIFICATIONREFERENCE($,'21-04 40 30','Fire Protection Specialties',#1260,$,$); -#1266=IFCCLASSIFICATIONREFERENCE($,'21-04 40 30 10','Fire Protection Cabinets',#1265,$,$); -#1267=IFCCLASSIFICATIONREFERENCE($,'21-04 40 30 30','Fire Extinguishers',#1265,$,$); -#1268=IFCCLASSIFICATIONREFERENCE($,'21-04 40 30 50','Breathing Air Replenishment Systems',#1265,$,$); -#1269=IFCCLASSIFICATIONREFERENCE($,'21-04 40 30 70','Fire Extinguisher Accessories',#1265,$,$); -#1270=IFCCLASSIFICATIONREFERENCE($,'21-04 50','Electrical',#1177,$,$); -#1271=IFCCLASSIFICATIONREFERENCE($,'21-04 50 10','Facility Power Generation',#1270,$,$); -#1272=IFCCLASSIFICATIONREFERENCE($,'21-04 50 10 10','Packaged Generator Assemblies',#1271,$,$); -#1273=IFCCLASSIFICATIONREFERENCE($,'21-04 50 10 20','Battery Equipment',#1271,$,$); -#1274=IFCCLASSIFICATIONREFERENCE($,'21-04 50 10 30','Photovoltaic Collectors',#1271,$,$); -#1275=IFCCLASSIFICATIONREFERENCE($,'21-04 50 10 40','Fuel Cells',#1271,$,$); -#1276=IFCCLASSIFICATIONREFERENCE($,'21-04 50 10 60','Power Filtering and Conditioning',#1271,$,$); -#1277=IFCCLASSIFICATIONREFERENCE($,'21-04 50 10 70','Transfer Switches',#1271,$,$); -#1278=IFCCLASSIFICATIONREFERENCE($,'21-04 50 10 90','Facility Power Generation Supplementary Components',#1271,$,$); -#1279=IFCCLASSIFICATIONREFERENCE($,'21-04 50 20','Electrical Service and Distribution',#1270,$,$); -#1280=IFCCLASSIFICATIONREFERENCE($,'21-04 50 20 10','Electrical Service',#1279,$,$); -#1281=IFCCLASSIFICATIONREFERENCE($,'21-04 50 20 30','Power Distribution',#1279,$,$); -#1282=IFCCLASSIFICATIONREFERENCE($,'21-04 50 20 70','Facility Grounding',#1279,$,$); -#1283=IFCCLASSIFICATIONREFERENCE($,'21-04 50 20 90','Electrical Service and Distribution Supplementary Components',#1279,$,$); -#1284=IFCCLASSIFICATIONREFERENCE($,'21-04 50 30','General Purpose Electrical Power',#1270,$,$); -#1285=IFCCLASSIFICATIONREFERENCE($,'21-04 50 30 10','Branch Wiring System',#1284,$,$); -#1286=IFCCLASSIFICATIONREFERENCE($,'21-04 50 30 50','Wiring Devices',#1284,$,$); -#1287=IFCCLASSIFICATIONREFERENCE($,'21-04 50 30 90','General Purpose Electrical Power Supplementary Components',#1284,$,$); -#1288=IFCCLASSIFICATIONREFERENCE($,'21-04 50 40','Lighting',#1270,$,$); -#1289=IFCCLASSIFICATIONREFERENCE($,'21-04 50 40 10','Lighting Control',#1288,$,$); -#1290=IFCCLASSIFICATIONREFERENCE($,'21-04 50 40 20','Branch Wiring for Lighting',#1288,$,$); -#1291=IFCCLASSIFICATIONREFERENCE($,'21-04 50 40 50','Lighting Fixtures',#1288,$,$); -#1292=IFCCLASSIFICATIONREFERENCE($,'21-04 50 40 90','Lighting Supplementary Components',#1288,$,$); -#1293=IFCCLASSIFICATIONREFERENCE($,'21-04 50 80','Miscellaneous Electrical Systems',#1270,$,$); -#1294=IFCCLASSIFICATIONREFERENCE($,'21-04 50 80 10','Lightning Protection',#1293,$,$); -#1295=IFCCLASSIFICATIONREFERENCE($,'21-04 50 80 40','Cathodic Protection',#1293,$,$); -#1296=IFCCLASSIFICATIONREFERENCE($,'21-04 50 80 70','Transient Voltage Suppression',#1293,$,$); -#1297=IFCCLASSIFICATIONREFERENCE($,'21-04 50 80 90','Miscellaneous Electrical Systems Supplementary Components',#1293,$,$); -#1298=IFCCLASSIFICATIONREFERENCE($,'21-04 60','Communications',#1177,$,$); -#1299=IFCCLASSIFICATIONREFERENCE($,'21-04 60 10','Data Communications',#1298,$,$); -#1300=IFCCLASSIFICATIONREFERENCE($,'21-04 60 10 10','Data Communications Network Equipment',#1299,$,$); -#1301=IFCCLASSIFICATIONREFERENCE($,'21-04 60 10 20','Data Communications Hardware',#1299,$,$); -#1302=IFCCLASSIFICATIONREFERENCE($,'21-04 60 10 30','Data Communications Peripheral Data Equipment',#1299,$,$); -#1303=IFCCLASSIFICATIONREFERENCE($,'21-04 60 10 50','Data Communications Software',#1299,$,$); -#1304=IFCCLASSIFICATIONREFERENCE($,'21-04 60 10 60','Data Communication Program and Integration Services',#1299,$,$); -#1305=IFCCLASSIFICATIONREFERENCE($,'21-04 60 20','Voice Communications',#1298,$,$); -#1306=IFCCLASSIFICATIONREFERENCE($,'21-04 60 20 10','Voice Communications Switching and Routing Equipment',#1305,$,$); -#1307=IFCCLASSIFICATIONREFERENCE($,'21-04 60 20 20','Voice Communications Terminal Equipment',#1305,$,$); -#1308=IFCCLASSIFICATIONREFERENCE($,'21-04 60 20 30','Voice Communications Messaging',#1305,$,$); -#1309=IFCCLASSIFICATIONREFERENCE($,'21-04 60 20 40','Call Accounting',#1305,$,$); -#1310=IFCCLASSIFICATIONREFERENCE($,'21-04 60 20 50','Call Management',#1305,$,$); -#1311=IFCCLASSIFICATIONREFERENCE($,'21-04 60 30','Audio-Video Communication',#1298,$,$); -#1312=IFCCLASSIFICATIONREFERENCE($,'21-04 60 30 10','Audio-Video Systems',#1311,$,$); -#1313=IFCCLASSIFICATIONREFERENCE($,'21-04 60 30 50','Electronic Digital Systems',#1311,$,$); -#1314=IFCCLASSIFICATIONREFERENCE($,'21-04 60 60','Distributed Communications and Monitoring',#1298,$,$); -#1315=IFCCLASSIFICATIONREFERENCE($,'21-04 60 60 10','Distributed Audio-Video Communications Systems',#1314,$,$); -#1316=IFCCLASSIFICATIONREFERENCE($,'21-04 60 60 30','Healthcare Communications and Monitoring',#1314,$,$); -#1317=IFCCLASSIFICATIONREFERENCE($,'21-04 60 60 50','Distributed Systems',#1314,$,$); -#1318=IFCCLASSIFICATIONREFERENCE($,'21-04 60 90','Communications Supplementary Components',#1298,$,$); -#1319=IFCCLASSIFICATIONREFERENCE($,'21-04 60 90 10','Supplementary Components',#1318,$,$); -#1320=IFCCLASSIFICATIONREFERENCE($,'21-04 70','Electronic Safety and Security',#1177,$,$); -#1321=IFCCLASSIFICATIONREFERENCE($,'21-04 70 10','Access Control and Intrusion Detection',#1320,$,$); -#1322=IFCCLASSIFICATIONREFERENCE($,'21-04 70 10 10','Access Control',#1321,$,$); -#1323=IFCCLASSIFICATIONREFERENCE($,'21-04 70 10 50','Intrusion Detection',#1321,$,$); -#1324=IFCCLASSIFICATIONREFERENCE($,'21-04 70 30','Electronic Surveillance',#1320,$,$); -#1325=IFCCLASSIFICATIONREFERENCE($,'21-04 70 30 10','Video Surveillance',#1324,$,$); -#1326=IFCCLASSIFICATIONREFERENCE($,'21-04 70 30 50','Electronic Personal Protection',#1324,$,$); -#1327=IFCCLASSIFICATIONREFERENCE($,'21-04 70 50','Detection and Alarm',#1320,$,$); -#1328=IFCCLASSIFICATIONREFERENCE($,'21-04 70 50 10','Fire Detection and Alarm',#1327,$,$); -#1329=IFCCLASSIFICATIONREFERENCE($,'21-04 70 50 20','Radiation Detection and Alarm',#1327,$,$); -#1330=IFCCLASSIFICATIONREFERENCE($,'21-04 70 50 30','Fuel-Gas Detection and Alarm',#1327,$,$); -#1331=IFCCLASSIFICATIONREFERENCE($,'21-04 70 50 40','Fuel-Oil Detection and Alarm',#1327,$,$); -#1332=IFCCLASSIFICATIONREFERENCE($,'21-04 70 50 50','Refrigeration Detection and Alarm',#1327,$,$); -#1333=IFCCLASSIFICATIONREFERENCE($,'21-04 70 50 60','Water Intrusion Detection and Alarm',#1327,$,$); -#1334=IFCCLASSIFICATIONREFERENCE($,'21-04 70 70','Electronic Monitoring and Control',#1320,$,$); -#1335=IFCCLASSIFICATIONREFERENCE($,'21-04 70 70 10','Electronic Detention Monitoring and Control',#1334,$,$); -#1336=IFCCLASSIFICATIONREFERENCE($,'21-04 70 90','Electronic Safety and Security Supplementary Components',#1320,$,$); -#1337=IFCCLASSIFICATIONREFERENCE($,'21-04 70 90 10','Supplementary Components',#1336,$,$); -#1338=IFCCLASSIFICATIONREFERENCE($,'21-04 80','Integrated Automation',#1177,$,$); -#1339=IFCCLASSIFICATIONREFERENCE($,'21-04 80 10','Integrated Automation Facility Controls',#1338,$,$); -#1340=IFCCLASSIFICATIONREFERENCE($,'21-04 80 10 10','Integrated Automation Control of Equipment',#1339,$,$); -#1341=IFCCLASSIFICATIONREFERENCE($,'21-04 80 10 20','Integrated Automation Control of Conveying Equipment',#1339,$,$); -#1342=IFCCLASSIFICATIONREFERENCE($,'21-04 80 10 30','Integrated Automation Control of Fire-Suppression Systems',#1339,$,$); -#1343=IFCCLASSIFICATIONREFERENCE($,'21-04 80 10 40','Integrated Automation Control of Plumbing Systems',#1339,$,$); -#1344=IFCCLASSIFICATIONREFERENCE($,'21-04 80 10 50','Integrated Automation Control of HVAC Systems',#1339,$,$); -#1345=IFCCLASSIFICATIONREFERENCE($,'21-04 80 10 60','Integrated Automation Control of Electrical Systems',#1339,$,$); -#1346=IFCCLASSIFICATIONREFERENCE($,'21-04 80 10 70','Integrated Automation Control of Communication Systems',#1339,$,$); -#1347=IFCCLASSIFICATIONREFERENCE($,'21-04 80 10 80','Integrated Automation Control of Electronic Safety and Security Systems',#1339,$,$); -#1348=IFCCLASSIFICATIONREFERENCE($,'21-04 80 10 90','Integrated Automation Supplementary Components',#1339,$,$); -#1349=IFCCLASSIFICATIONREFERENCE($,'21-05 00 00','Equipment and Furnishings',#962,$,$); -#1350=IFCCLASSIFICATIONREFERENCE($,'21-05 10','Equipment',#1349,$,$); -#1351=IFCCLASSIFICATIONREFERENCE($,'21-05 10 10','Vehicle and Pedestrian Equipment',#1350,$,$); -#1352=IFCCLASSIFICATIONREFERENCE($,'21-05 10 10 10','Vehicle Servicing Equipment',#1351,$,$); -#1353=IFCCLASSIFICATIONREFERENCE($,'21-05 10 10 30','Interior Parking Control Equipment',#1351,$,$); -#1354=IFCCLASSIFICATIONREFERENCE($,'21-05 10 10 50','Loading Dock Equipment',#1351,$,$); -#1355=IFCCLASSIFICATIONREFERENCE($,'21-05 10 10 70','Interior Pedestrian Control Equipment',#1351,$,$); -#1356=IFCCLASSIFICATIONREFERENCE($,'21-05 10 30','Commercial Equipment',#1350,$,$); -#1357=IFCCLASSIFICATIONREFERENCE($,'21-05 10 30 10','Mercantile and Service Equipment',#1356,$,$); -#1358=IFCCLASSIFICATIONREFERENCE($,'21-05 10 30 20','Vault Equipment',#1356,$,$); -#1359=IFCCLASSIFICATIONREFERENCE($,'21-05 10 30 25','Teller and Service Equipment',#1356,$,$); -#1360=IFCCLASSIFICATIONREFERENCE($,'21-05 10 30 30','Refrigerated Display Equipment',#1356,$,$); -#1361=IFCCLASSIFICATIONREFERENCE($,'21-05 10 30 35','Commercial Laundry and Dry Cleaning Equipment',#1356,$,$); -#1362=IFCCLASSIFICATIONREFERENCE($,'21-05 10 30 40','Maintenance Equipment',#1356,$,$); -#1363=IFCCLASSIFICATIONREFERENCE($,'21-05 10 30 50','Hospitality Equipment',#1356,$,$); -#1364=IFCCLASSIFICATIONREFERENCE($,'21-05 10 30 55','Unit Kitchens',#1356,$,$); -#1365=IFCCLASSIFICATIONREFERENCE($,'21-05 10 30 60','Photographic Processing Equipment',#1356,$,$); -#1366=IFCCLASSIFICATIONREFERENCE($,'21-05 10 30 70','Postal, Packaging, and Shipping Equipment',#1356,$,$); -#1367=IFCCLASSIFICATIONREFERENCE($,'21-05 10 30 75','Office Equipment',#1356,$,$); -#1368=IFCCLASSIFICATIONREFERENCE($,'21-05 10 30 80','Foodservice Equipment',#1356,$,$); -#1369=IFCCLASSIFICATIONREFERENCE($,'21-05 10 40','Institutional Equipment',#1350,$,$); -#1370=IFCCLASSIFICATIONREFERENCE($,'21-05 10 40 10','Educational and Scientific Equipment',#1369,$,$); -#1371=IFCCLASSIFICATIONREFERENCE($,'21-05 10 40 20','Healthcare Equipment',#1369,$,$); -#1372=IFCCLASSIFICATIONREFERENCE($,'21-05 10 40 40','Religious Equipment',#1369,$,$); -#1373=IFCCLASSIFICATIONREFERENCE($,'21-05 10 40 60','Security Equipment',#1369,$,$); -#1374=IFCCLASSIFICATIONREFERENCE($,'21-05 10 40 70','Detention Equipment',#1369,$,$); -#1375=IFCCLASSIFICATIONREFERENCE($,'21-05 10 60','Residential Equipment',#1350,$,$); -#1376=IFCCLASSIFICATIONREFERENCE($,'21-05 10 60 10','Residential Appliances',#1375,$,$); -#1377=IFCCLASSIFICATIONREFERENCE($,'21-05 10 60 50','Retractable Stairs',#1375,$,$); -#1378=IFCCLASSIFICATIONREFERENCE($,'21-05 10 60 70','Residential Ceiling Fans',#1375,$,$); -#1379=IFCCLASSIFICATIONREFERENCE($,'21-05 10 70','Entertainment and Recreational Equipment',#1350,$,$); -#1380=IFCCLASSIFICATIONREFERENCE($,'21-05 10 70 10','Theater and Stage Equipment',#1379,$,$); -#1381=IFCCLASSIFICATIONREFERENCE($,'21-05 10 70 20','Musical Equipment',#1379,$,$); -#1382=IFCCLASSIFICATIONREFERENCE($,'21-05 10 70 50','Athletic Equipment',#1379,$,$); -#1383=IFCCLASSIFICATIONREFERENCE($,'21-05 10 70 60','Recreational Equipment',#1379,$,$); -#1384=IFCCLASSIFICATIONREFERENCE($,'21-05 10 90','Other Equipment',#1350,$,$); -#1385=IFCCLASSIFICATIONREFERENCE($,'21-05 10 90 10','Solid Waste Handling Equipment',#1384,$,$); -#1386=IFCCLASSIFICATIONREFERENCE($,'21-05 10 90 30','Agricultural Equipment',#1384,$,$); -#1387=IFCCLASSIFICATIONREFERENCE($,'21-05 10 90 40','Horticultural Equipment',#1384,$,$); -#1388=IFCCLASSIFICATIONREFERENCE($,'21-05 10 90 60','Decontamination Equipment',#1384,$,$); -#1389=IFCCLASSIFICATIONREFERENCE($,'21-05 20','Furnishings',#1349,$,$); -#1390=IFCCLASSIFICATIONREFERENCE($,'21-05 20 10','Fixed Furnishings',#1389,$,$); -#1391=IFCCLASSIFICATIONREFERENCE($,'21-05 20 10 10','Fixed Art',#1390,$,$); -#1392=IFCCLASSIFICATIONREFERENCE($,'21-05 20 10 20','Window Treatments',#1390,$,$); -#1393=IFCCLASSIFICATIONREFERENCE($,'21-05 20 10 30','Casework',#1390,$,$); -#1394=IFCCLASSIFICATIONREFERENCE($,'21-05 20 10 70','Fixed Multiple Seating',#1390,$,$); -#1395=IFCCLASSIFICATIONREFERENCE($,'21-05 20 10 90','Other Fixed Furnishings',#1390,$,$); -#1396=IFCCLASSIFICATIONREFERENCE($,'21-05 20 50','Movable Furnishings',#1389,$,$); -#1397=IFCCLASSIFICATIONREFERENCE($,'21-05 20 50 10','Movable Art',#1396,$,$); -#1398=IFCCLASSIFICATIONREFERENCE($,'21-05 20 50 30','Furniture',#1396,$,$); -#1399=IFCCLASSIFICATIONREFERENCE($,'21-05 20 50 40','Accessories',#1396,$,$); -#1400=IFCCLASSIFICATIONREFERENCE($,'21-05 20 50 60','Movable Multiple Seating',#1396,$,$); -#1401=IFCCLASSIFICATIONREFERENCE($,'21-05 20 50 90','Other Movable Furnishings',#1396,$,$); -#1402=IFCCLASSIFICATIONREFERENCE($,'21-06 00 00','Special Construction and Demolition',#962,$,$); -#1403=IFCCLASSIFICATIONREFERENCE($,'21-06 10','Special Construction',#1402,$,$); -#1404=IFCCLASSIFICATIONREFERENCE($,'21-06 10 10','Integrated Construction',#1403,$,$); -#1405=IFCCLASSIFICATIONREFERENCE($,'21-06 10 10 10','Building Modules',#1404,$,$); -#1406=IFCCLASSIFICATIONREFERENCE($,'21-06 10 10 50','Manufactured/Fabricated Rooms',#1404,$,$); -#1407=IFCCLASSIFICATIONREFERENCE($,'21-06 10 10 70','Modular Mezzanines',#1404,$,$); -#1408=IFCCLASSIFICATIONREFERENCE($,'21-06 10 20','Special Structures',#1403,$,$); -#1409=IFCCLASSIFICATIONREFERENCE($,'21-06 10 20 10','Fabric Structures',#1408,$,$); -#1410=IFCCLASSIFICATIONREFERENCE($,'21-06 10 20 20','Space Frames',#1408,$,$); -#1411=IFCCLASSIFICATIONREFERENCE($,'21-06 10 20 30','Geodesic Structures',#1408,$,$); -#1412=IFCCLASSIFICATIONREFERENCE($,'21-06 10 20 40','Manufacturer-Engineered Structures',#1408,$,$); -#1413=IFCCLASSIFICATIONREFERENCE($,'21-06 10 20 60','Manufactured Canopies',#1408,$,$); -#1414=IFCCLASSIFICATIONREFERENCE($,'21-06 10 20 65','Rammed Earth Construction',#1408,$,$); -#1415=IFCCLASSIFICATIONREFERENCE($,'21-06 10 20 70','Towers',#1408,$,$); -#1416=IFCCLASSIFICATIONREFERENCE($,'21-06 10 30','Special Function Construction',#1403,$,$); -#1417=IFCCLASSIFICATIONREFERENCE($,'21-06 10 30 10','Sound and Vibration Control',#1416,$,$); -#1418=IFCCLASSIFICATIONREFERENCE($,'21-06 10 30 30','Seismic Control',#1416,$,$); -#1419=IFCCLASSIFICATIONREFERENCE($,'21-06 10 30 50','Radiation Protection',#1416,$,$); -#1420=IFCCLASSIFICATIONREFERENCE($,'21-06 10 50','Special Facility Components',#1403,$,$); -#1421=IFCCLASSIFICATIONREFERENCE($,'21-06 10 50 10','Pools',#1420,$,$); -#1422=IFCCLASSIFICATIONREFERENCE($,'21-06 10 50 20','Interior Fountains',#1420,$,$); -#1423=IFCCLASSIFICATIONREFERENCE($,'21-06 10 50 30','Interior Water Features',#1420,$,$); -#1424=IFCCLASSIFICATIONREFERENCE($,'21-06 10 50 40','Aquariums',#1420,$,$); -#1425=IFCCLASSIFICATIONREFERENCE($,'21-06 10 50 50','Amusement Park Structures and Equipment',#1420,$,$); -#1426=IFCCLASSIFICATIONREFERENCE($,'21-06 10 50 60','Ice Rinks',#1420,$,$); -#1427=IFCCLASSIFICATIONREFERENCE($,'21-06 10 50 70','Animal Containment',#1420,$,$); -#1428=IFCCLASSIFICATIONREFERENCE($,'21-06 10 60','Athletic and Recreational Special Construction',#1403,$,$); -#1429=IFCCLASSIFICATIONREFERENCE($,'21-06 10 60 10','Indoor Soccer Boards',#1428,$,$); -#1430=IFCCLASSIFICATIONREFERENCE($,'21-06 10 60 20','Safety Netting',#1428,$,$); -#1431=IFCCLASSIFICATIONREFERENCE($,'21-06 10 60 30','Arena Football Boards',#1428,$,$); -#1432=IFCCLASSIFICATIONREFERENCE($,'21-06 10 60 40','Floor Sockets',#1428,$,$); -#1433=IFCCLASSIFICATIONREFERENCE($,'21-06 10 60 50','Athletic and Recreational Court Walls',#1428,$,$); -#1434=IFCCLASSIFICATIONREFERENCE($,'21-06 10 60 60','Demountable Athletic Surfaces',#1428,$,$); -#1435=IFCCLASSIFICATIONREFERENCE($,'21-06 10 80','Special Instrumentation',#1403,$,$); -#1436=IFCCLASSIFICATIONREFERENCE($,'21-06 10 80 10','Stress Instrumentation',#1435,$,$); -#1437=IFCCLASSIFICATIONREFERENCE($,'21-06 10 80 20','Seismic Instrumentation',#1435,$,$); -#1438=IFCCLASSIFICATIONREFERENCE($,'21-06 10 80 40','Meteorological Instrumentation',#1435,$,$); -#1439=IFCCLASSIFICATIONREFERENCE($,'21-06 10 80 60','Earth Movement Monitoring',#1435,$,$); -#1440=IFCCLASSIFICATIONREFERENCE($,'21-06 20','Facility Remediation',#1402,$,$); -#1441=IFCCLASSIFICATIONREFERENCE($,'21-06 20 10','Hazardous Materials Remediation',#1440,$,$); -#1442=IFCCLASSIFICATIONREFERENCE($,'21-06 20 10 10','Transportation and Disposal of Hazardous Materials',#1441,$,$); -#1443=IFCCLASSIFICATIONREFERENCE($,'21-06 20 10 20','Asbestos Remediation',#1441,$,$); -#1444=IFCCLASSIFICATIONREFERENCE($,'21-06 20 10 30','Lead Remediation',#1441,$,$); -#1445=IFCCLASSIFICATIONREFERENCE($,'21-06 20 10 40','Polychlorinate Biphenyl Remediation',#1441,$,$); -#1446=IFCCLASSIFICATIONREFERENCE($,'21-06 20 10 50','Mold Remediation',#1441,$,$); -#1447=IFCCLASSIFICATIONREFERENCE($,'21-06 30','Demolition',#1402,$,$); -#1448=IFCCLASSIFICATIONREFERENCE($,'21-06 30 10','Structure Demolition',#1447,$,$); -#1449=IFCCLASSIFICATIONREFERENCE($,'21-06 30 10 10','Building Demolition',#1448,$,$); -#1450=IFCCLASSIFICATIONREFERENCE($,'21-06 30 10 30','Tower Demolition',#1448,$,$); -#1451=IFCCLASSIFICATIONREFERENCE($,'21-06 30 10 50','Bridge Demolition',#1448,$,$); -#1452=IFCCLASSIFICATIONREFERENCE($,'21-06 30 10 70','Dam Demolition',#1448,$,$); -#1453=IFCCLASSIFICATIONREFERENCE($,'21-06 30 30','Selective Demolition',#1447,$,$); -#1454=IFCCLASSIFICATIONREFERENCE($,'21-06 30 30 10','Selective Building Demolition',#1453,$,$); -#1455=IFCCLASSIFICATIONREFERENCE($,'21-06 30 30 30','Selective Interior Demolition',#1453,$,$); -#1456=IFCCLASSIFICATIONREFERENCE($,'21-06 30 30 50','Selective Bridge Demolition',#1453,$,$); -#1457=IFCCLASSIFICATIONREFERENCE($,'21-06 30 30 70','Selective Historic Demolition',#1453,$,$); -#1458=IFCCLASSIFICATIONREFERENCE($,'21-06 30 50','Structure Moving',#1447,$,$); -#1459=IFCCLASSIFICATIONREFERENCE($,'21-06 30 50 10','Structure Relocation',#1458,$,$); -#1460=IFCCLASSIFICATIONREFERENCE($,'21-06 30 50 30','Structure Raising',#1458,$,$); -#1461=IFCCLASSIFICATIONREFERENCE($,'21-07 00 00','Sitework',#962,$,$); -#1462=IFCCLASSIFICATIONREFERENCE($,'21-07 10','Site Preparation',#1461,$,$); -#1463=IFCCLASSIFICATIONREFERENCE($,'21-07 10 10','Site Clearing',#1462,$,$); -#1464=IFCCLASSIFICATIONREFERENCE($,'21-07 10 10 10','Clearing and Grubbing',#1463,$,$); -#1465=IFCCLASSIFICATIONREFERENCE($,'21-07 10 10 30','Tree and Shrub Removal and Trimming',#1463,$,$); -#1466=IFCCLASSIFICATIONREFERENCE($,'21-07 10 10 50','Earth Stripping and Stockpiling',#1463,$,$); -#1467=IFCCLASSIFICATIONREFERENCE($,'21-07 10 20','Site Elements Demolition',#1462,$,$); -#1468=IFCCLASSIFICATIONREFERENCE($,'21-07 10 20 10','Utility Demolition',#1467,$,$); -#1469=IFCCLASSIFICATIONREFERENCE($,'21-07 10 20 30','Infrastructure Demolition',#1467,$,$); -#1470=IFCCLASSIFICATIONREFERENCE($,'21-07 10 20 50','Selective Site Demolition',#1467,$,$); -#1471=IFCCLASSIFICATIONREFERENCE($,'21-07 10 30','Site Element Relocations',#1462,$,$); -#1472=IFCCLASSIFICATIONREFERENCE($,'21-07 10 30 10','Utility Relocation',#1471,$,$); -#1473=IFCCLASSIFICATIONREFERENCE($,'21-07 10 50','Site Remediation',#1462,$,$); -#1474=IFCCLASSIFICATIONREFERENCE($,'21-07 10 50 10','Physical Decontamination',#1473,$,$); -#1475=IFCCLASSIFICATIONREFERENCE($,'21-07 10 50 15','Chemical Decontamination',#1473,$,$); -#1476=IFCCLASSIFICATIONREFERENCE($,'21-07 10 50 20','Thermal Decontamination',#1473,$,$); -#1477=IFCCLASSIFICATIONREFERENCE($,'21-07 10 50 25','Biological Decontamination',#1473,$,$); -#1478=IFCCLASSIFICATIONREFERENCE($,'21-07 10 50 30','Remediation Soil Stabilization',#1473,$,$); -#1479=IFCCLASSIFICATIONREFERENCE($,'21-07 10 50 40','Site Containment',#1473,$,$); -#1480=IFCCLASSIFICATIONREFERENCE($,'21-07 10 50 45','Sinkhole Remediation',#1473,$,$); -#1481=IFCCLASSIFICATIONREFERENCE($,'21-07 10 50 50','Hazardous Waste Drum Handling',#1473,$,$); -#1482=IFCCLASSIFICATIONREFERENCE($,'21-07 10 50 60','Contaminated Site Material Removal',#1473,$,$); -#1483=IFCCLASSIFICATIONREFERENCE($,'21-07 10 50 80','Water Remediation',#1473,$,$); -#1484=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70','Site Earthwork',#1462,$,$); -#1485=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70 10','Grading',#1484,$,$); -#1486=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70 20','Excavation and Fill',#1484,$,$); -#1487=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70 30','Embankments',#1484,$,$); -#1488=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70 35','Erosion and Sedimentation Controls',#1484,$,$); -#1489=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70 40','Soil Stabilization',#1484,$,$); -#1490=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70 45','Rock Stabilization',#1484,$,$); -#1491=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70 50','Soil Reinforcement',#1484,$,$); -#1492=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70 55','Slope Protection',#1484,$,$); -#1493=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70 60','Gabions',#1484,$,$); -#1494=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70 65','Riprap',#1484,$,$); -#1495=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70 70','Wetlands',#1484,$,$); -#1496=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70 80','Earth Dams',#1484,$,$); -#1497=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70 90','Site Soil Treatment',#1484,$,$); -#1498=IFCCLASSIFICATIONREFERENCE($,'21-07 20','Site Improvements',#1461,$,$); -#1499=IFCCLASSIFICATIONREFERENCE($,'21-07 20 10','Roadways',#1498,$,$); -#1500=IFCCLASSIFICATIONREFERENCE($,'21-07 20 10 10','Roadway Pavement',#1499,$,$); -#1501=IFCCLASSIFICATIONREFERENCE($,'21-07 20 10 20','Roadway Curbs and Gutters',#1499,$,$); -#1502=IFCCLASSIFICATIONREFERENCE($,'21-07 20 10 40','Roadway Appurtenances',#1499,$,$); -#1503=IFCCLASSIFICATIONREFERENCE($,'21-07 20 10 70','Roadway Lighting',#1499,$,$); -#1504=IFCCLASSIFICATIONREFERENCE($,'21-07 20 10 80','Vehicle Fare Collection',#1499,$,$); -#1505=IFCCLASSIFICATIONREFERENCE($,'21-07 20 20','Parking Lots',#1498,$,$); -#1506=IFCCLASSIFICATIONREFERENCE($,'21-07 20 20 10','Parking Lot Pavement',#1505,$,$); -#1507=IFCCLASSIFICATIONREFERENCE($,'21-07 20 20 20','Parking Lot Curbs and Gutters',#1505,$,$); -#1508=IFCCLASSIFICATIONREFERENCE($,'21-07 20 20 40','Parking Lot Appurtenances',#1505,$,$); -#1509=IFCCLASSIFICATIONREFERENCE($,'21-07 20 20 70','Parking Lot Lighting',#1505,$,$); -#1510=IFCCLASSIFICATIONREFERENCE($,'21-07 20 20 80','Exterior Parking Control Equipment',#1505,$,$); -#1511=IFCCLASSIFICATIONREFERENCE($,'21-07 20 30','Pedestrian Plazas and Walkways',#1498,$,$); -#1512=IFCCLASSIFICATIONREFERENCE($,'21-07 20 30 10','Pedestrian Pavement',#1511,$,$); -#1513=IFCCLASSIFICATIONREFERENCE($,'21-07 20 30 20','Pedestrian Pavement Curbs and Gutters',#1511,$,$); -#1514=IFCCLASSIFICATIONREFERENCE($,'21-07 20 30 30','Exterior Steps and Ramps',#1511,$,$); -#1515=IFCCLASSIFICATIONREFERENCE($,'21-07 20 30 40','Pedestrian Pavement Appurtenances',#1511,$,$); -#1516=IFCCLASSIFICATIONREFERENCE($,'21-07 20 30 70','Plaza and Walkway Lighting',#1511,$,$); -#1517=IFCCLASSIFICATIONREFERENCE($,'21-07 20 30 80','Exterior Pedestrian Control Equipment',#1511,$,$); -#1518=IFCCLASSIFICATIONREFERENCE($,'21-07 20 40','Airfields',#1498,$,$); -#1519=IFCCLASSIFICATIONREFERENCE($,'21-07 20 40 10','Aviation Pavement',#1518,$,$); -#1520=IFCCLASSIFICATIONREFERENCE($,'21-07 20 40 20','Aviation Pavement Curbs and Gutters',#1518,$,$); -#1521=IFCCLASSIFICATIONREFERENCE($,'21-07 20 40 40','Aviation Pavement Appurtenances',#1518,$,$); -#1522=IFCCLASSIFICATIONREFERENCE($,'21-07 20 40 70','Airfield Lighting',#1518,$,$); -#1523=IFCCLASSIFICATIONREFERENCE($,'21-07 20 40 80','Airfield Signaling and Control Equipment',#1518,$,$); -#1524=IFCCLASSIFICATIONREFERENCE($,'21-07 20 50','Athletic, Recreational, and Playfield Areas',#1498,$,$); -#1525=IFCCLASSIFICATIONREFERENCE($,'21-07 20 50 10','Athletic Areas',#1524,$,$); -#1526=IFCCLASSIFICATIONREFERENCE($,'21-07 20 50 30','Recreational Areas',#1524,$,$); -#1527=IFCCLASSIFICATIONREFERENCE($,'21-07 20 50 50','Playfield Areas',#1524,$,$); -#1528=IFCCLASSIFICATIONREFERENCE($,'21-07 20 60','Site Development',#1498,$,$); -#1529=IFCCLASSIFICATIONREFERENCE($,'21-07 20 60 10','Exterior Fountains',#1528,$,$); -#1530=IFCCLASSIFICATIONREFERENCE($,'21-07 20 60 20','Fences and Gates',#1528,$,$); -#1531=IFCCLASSIFICATIONREFERENCE($,'21-07 20 60 25','Site Furnishings',#1528,$,$); -#1532=IFCCLASSIFICATIONREFERENCE($,'21-07 20 60 30','Exterior Signage',#1528,$,$); -#1533=IFCCLASSIFICATIONREFERENCE($,'21-07 20 60 35','Flagpoles',#1528,$,$); -#1534=IFCCLASSIFICATIONREFERENCE($,'21-07 20 60 40','Covers and Shelters',#1528,$,$); -#1535=IFCCLASSIFICATIONREFERENCE($,'21-07 20 60 45','Exterior Gas Lighting',#1528,$,$); -#1536=IFCCLASSIFICATIONREFERENCE($,'21-07 20 60 50','Site Equipment',#1528,$,$); -#1537=IFCCLASSIFICATIONREFERENCE($,'21-07 20 60 60','Retaining Walls',#1528,$,$); -#1538=IFCCLASSIFICATIONREFERENCE($,'21-07 20 60 70','Site Bridges',#1528,$,$); -#1539=IFCCLASSIFICATIONREFERENCE($,'21-07 20 60 80','Site Screening Devices',#1528,$,$); -#1540=IFCCLASSIFICATIONREFERENCE($,'21-07 20 60 85','Site Specialties',#1528,$,$); -#1541=IFCCLASSIFICATIONREFERENCE($,'21-07 20 80','Landscaping',#1498,$,$); -#1542=IFCCLASSIFICATIONREFERENCE($,'21-07 20 80 10','Planting Irrigation',#1541,$,$); -#1543=IFCCLASSIFICATIONREFERENCE($,'21-07 20 80 20','Turf and Grasses',#1541,$,$); -#1544=IFCCLASSIFICATIONREFERENCE($,'21-07 20 80 30','Plants',#1541,$,$); -#1545=IFCCLASSIFICATIONREFERENCE($,'21-07 20 80 50','Planting Accessories',#1541,$,$); -#1546=IFCCLASSIFICATIONREFERENCE($,'21-07 20 80 70','Landscape Lighting',#1541,$,$); -#1547=IFCCLASSIFICATIONREFERENCE($,'21-07 20 80 80','Landscaping Activities',#1541,$,$); -#1548=IFCCLASSIFICATIONREFERENCE($,'21-07 30','Liquid and Gas Site Utilities',#1461,$,$); -#1549=IFCCLASSIFICATIONREFERENCE($,'21-07 30 10','Water Utilities',#1548,$,$); -#1550=IFCCLASSIFICATIONREFERENCE($,'21-07 30 10 10','Site Domestic Water Distribution',#1549,$,$); -#1551=IFCCLASSIFICATIONREFERENCE($,'21-07 30 10 30','Site Fire Protection Water Distribution',#1549,$,$); -#1552=IFCCLASSIFICATIONREFERENCE($,'21-07 30 10 50','Site Irrigation Water Distribution',#1549,$,$); -#1553=IFCCLASSIFICATIONREFERENCE($,'21-07 30 20','Sanitary Sewerage Utilities',#1548,$,$); -#1554=IFCCLASSIFICATIONREFERENCE($,'21-07 30 20 10','Sanitary Sewerage Utility Connection',#1553,$,$); -#1555=IFCCLASSIFICATIONREFERENCE($,'21-07 30 20 20','Sanitary Sewerage Piping',#1553,$,$); -#1556=IFCCLASSIFICATIONREFERENCE($,'21-07 30 20 40','Utility Septic Tanks',#1553,$,$); -#1557=IFCCLASSIFICATIONREFERENCE($,'21-07 30 20 50','Sanitary Sewerage Structures',#1553,$,$); -#1558=IFCCLASSIFICATIONREFERENCE($,'21-07 30 20 60','Sanitary Sewerage Lagoons',#1553,$,$); -#1559=IFCCLASSIFICATIONREFERENCE($,'21-07 30 30','Storm Drainage Utilities',#1548,$,$); -#1560=IFCCLASSIFICATIONREFERENCE($,'21-07 30 30 10','Storm Drainage Utility Connection',#1559,$,$); -#1561=IFCCLASSIFICATIONREFERENCE($,'21-07 30 30 20','Storm Drainage Piping',#1559,$,$); -#1562=IFCCLASSIFICATIONREFERENCE($,'21-07 30 30 30','Culverts',#1559,$,$); -#1563=IFCCLASSIFICATIONREFERENCE($,'21-07 30 30 40','Site Storm Water Drains',#1559,$,$); -#1564=IFCCLASSIFICATIONREFERENCE($,'21-07 30 30 50','Storm Drainage Pumps',#1559,$,$); -#1565=IFCCLASSIFICATIONREFERENCE($,'21-07 30 30 60','Site Subdrainage',#1559,$,$); -#1566=IFCCLASSIFICATIONREFERENCE($,'21-07 30 30 70','Storm Drainage Ponds and Reservoirs',#1559,$,$); -#1567=IFCCLASSIFICATIONREFERENCE($,'21-07 30 50','Site Energy Distribution',#1548,$,$); -#1568=IFCCLASSIFICATIONREFERENCE($,'21-07 30 50 10','Site Hydronic Heating Distribution',#1567,$,$); -#1569=IFCCLASSIFICATIONREFERENCE($,'21-07 30 50 20','Site Steam Energy Distribution',#1567,$,$); -#1570=IFCCLASSIFICATIONREFERENCE($,'21-07 30 50 40','Site Hydronic Cooling Distribution',#1567,$,$); -#1571=IFCCLASSIFICATIONREFERENCE($,'21-07 30 60','Site Fuel Distribution',#1548,$,$); -#1572=IFCCLASSIFICATIONREFERENCE($,'21-07 30 60 10','Site Gas Distribution',#1571,$,$); -#1573=IFCCLASSIFICATIONREFERENCE($,'21-07 30 60 20','Site Fuel-Oil Distribution',#1571,$,$); -#1574=IFCCLASSIFICATIONREFERENCE($,'21-07 30 60 30','Site Gasoline Distribution',#1571,$,$); -#1575=IFCCLASSIFICATIONREFERENCE($,'21-07 30 60 40','Site Diesel Fuel Distribution',#1571,$,$); -#1576=IFCCLASSIFICATIONREFERENCE($,'21-07 30 60 60','Site Aviation Fuel Distribution',#1571,$,$); -#1577=IFCCLASSIFICATIONREFERENCE($,'21-07 30 90','Liquid and Gas Site Utilities Supplementary Components',#1548,$,$); -#1578=IFCCLASSIFICATIONREFERENCE($,'21-07 30 90 10','Supplementary Components',#1577,$,$); -#1579=IFCCLASSIFICATIONREFERENCE($,'21-07 40','Electrical Site Improvements',#1461,$,$); -#1580=IFCCLASSIFICATIONREFERENCE($,'21-07 40 10','Site Electric Distribution Systems',#1579,$,$); -#1581=IFCCLASSIFICATIONREFERENCE($,'21-07 40 10 10','Electrical Utility Services',#1580,$,$); -#1582=IFCCLASSIFICATIONREFERENCE($,'21-07 40 10 20','Electric Transmission and Distribution',#1580,$,$); -#1583=IFCCLASSIFICATIONREFERENCE($,'21-07 40 10 30','Electrical Substations',#1580,$,$); -#1584=IFCCLASSIFICATIONREFERENCE($,'21-07 40 10 40','Electrical Transformers',#1580,$,$); -#1585=IFCCLASSIFICATIONREFERENCE($,'21-07 40 10 50','Electrical Switchgear and Protection Devices',#1580,$,$); -#1586=IFCCLASSIFICATIONREFERENCE($,'21-07 40 10 70','Site Grounding',#1580,$,$); -#1587=IFCCLASSIFICATIONREFERENCE($,'21-07 40 10 90','Electrical Distribution System Instrumentation and Controls',#1580,$,$); -#1588=IFCCLASSIFICATIONREFERENCE($,'21-07 40 50','Site Lighting',#1579,$,$); -#1589=IFCCLASSIFICATIONREFERENCE($,'21-07 40 50 10','Area Lighting',#1588,$,$); -#1590=IFCCLASSIFICATIONREFERENCE($,'21-07 40 50 20','Flood Lighting',#1588,$,$); -#1591=IFCCLASSIFICATIONREFERENCE($,'21-07 40 50 50','Building Illumination',#1588,$,$); -#1592=IFCCLASSIFICATIONREFERENCE($,'21-07 40 50 90','Exterior Lighting Supplementary Components',#1588,$,$); -#1593=IFCCLASSIFICATIONREFERENCE($,'21-07 50','Site Communications',#1461,$,$); -#1594=IFCCLASSIFICATIONREFERENCE($,'21-07 50 10','Site Communications Systems',#1593,$,$); -#1595=IFCCLASSIFICATIONREFERENCE($,'21-07 50 10 10','Site Communications Structures',#1594,$,$); -#1596=IFCCLASSIFICATIONREFERENCE($,'21-07 50 10 30','Site Communications Distribution',#1594,$,$); -#1597=IFCCLASSIFICATIONREFERENCE($,'21-07 50 10 50','Wireless Communications Distribution',#1594,$,$); -#1598=IFCCLASSIFICATIONREFERENCE($,'21-07 90','Miscellaneous Site Construction',#1461,$,$); -#1599=IFCCLASSIFICATIONREFERENCE($,'21-07 90 10','Tunnels',#1598,$,$); -#1600=IFCCLASSIFICATIONREFERENCE($,'21-07 90 10 10','Vehicular Tunnels',#1599,$,$); -#1601=IFCCLASSIFICATIONREFERENCE($,'21-07 90 10 20','Pedestrian Tunnels',#1599,$,$); -#1602=IFCCLASSIFICATIONREFERENCE($,'21-07 90 10 40','Service Tunnels',#1599,$,$); -#1603=IFCCLASSIFICATIONREFERENCE($,'21-07 90 10 90','Tunnel Construction Related Activities',#1599,$,$); -#1604=IFCCLASSIFICATIONREFERENCE($,'Table 23 - Products',$,#1,'Assigns construction product classes to building elements based on this OmniClass (edition 2012) specification.\X2\000A000A\X0\''Apply'' creates a Classification Reference for selected IFC entity (IfcElement, IfcTypeProduct (except IfcSpaceType), IfcGroup and IfcSystem), using OmniClass-required attributes derived from the item that you choose in the following list.\X2\000A00090009\X0\',$); -#1605=IFCCLASSIFICATIONREFERENCE($,'23-11 00 00','Site Products',#1604,$,$); -#1606=IFCCLASSIFICATIONREFERENCE($,'23-11 11 00','Ground Anchorages',#1605,$,$); -#1607=IFCCLASSIFICATIONREFERENCE($,'23-11 11 11','Retaining Stabilizing Ground Anchors',#1606,$,$); -#1608=IFCCLASSIFICATIONREFERENCE($,'23-11 11 11 11','Retaining Stabilizing Ground Components',#1607,$,$); -#1609=IFCCLASSIFICATIONREFERENCE($,'23-11 11 11 11 11','Stabilizing Ground Anchor Heads',#1608,$,$); -#1610=IFCCLASSIFICATIONREFERENCE($,'23-11 11 11 11 13','Stabilizing Ground Tendons',#1608,$,$); -#1611=IFCCLASSIFICATIONREFERENCE($,'23-11 11 11 13','Stabilizing Ground Grouted Anchors',#1607,$,$); -#1612=IFCCLASSIFICATIONREFERENCE($,'23-11 11 11 15','Stabilizing Ground Plate Anchors',#1607,$,$); -#1613=IFCCLASSIFICATIONREFERENCE($,'23-11 11 11 17','Stabilizing Ground Rock Bolts',#1607,$,$); -#1614=IFCCLASSIFICATIONREFERENCE($,'23-11 11 11 19','Stabilizing Ground Rock Anchors',#1607,$,$); -#1615=IFCCLASSIFICATIONREFERENCE($,'23-11 11 11 21','Stabilizing Ground Anchor Tiebacks',#1607,$,$); -#1616=IFCCLASSIFICATIONREFERENCE($,'23-11 11 13','Earth Reinforcement Anchors',#1606,$,$); -#1617=IFCCLASSIFICATIONREFERENCE($,'23-11 11 13 11','Earth Reinforcement Soil Nails',#1616,$,$); -#1618=IFCCLASSIFICATIONREFERENCE($,'23-11 13 00','Ground Improvement Products',#1605,$,$); -#1619=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11','Soil Stabilization Products',#1618,$,$); -#1620=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 11','Soil Stabilization Injectable Chemicals',#1619,$,$); -#1621=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 13','Soil Stabilization Pressure Grouting',#1619,$,$); -#1622=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 15','Ground Freezing Soil Stabilization',#1619,$,$); -#1623=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 17','Soil Stabilization Fills',#1619,$,$); -#1624=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 17 11','Soil Stabilization Fill Blocks',#1623,$,$); -#1625=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 17 13','Soil Stabilization Compressible Fill',#1623,$,$); -#1626=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 19','Other Soil Stabilizations',#1619,$,$); -#1627=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 21','Piped Field Drainage',#1619,$,$); -#1628=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 21 11','Field Drainage Land Drainage Pipes',#1627,$,$); -#1629=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 23','Field Drainage Blocks',#1619,$,$); -#1630=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 25','Field Drainage Geocomposite Drains',#1619,$,$); -#1631=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 25 11','Field Drainage Geocomposite Edge Drains',#1630,$,$); -#1632=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 25 13','Field Drainage Geocomposite In Place Wall Drains',#1630,$,$); -#1633=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 27','Geotextile Subsurface Drainage Filtration',#1619,$,$); -#1634=IFCCLASSIFICATIONREFERENCE($,'23-11 15 00','Sheeting and Revetments',#1605,$,$); -#1635=IFCCLASSIFICATIONREFERENCE($,'23-11 15 11','Sheeting Geosynthetics',#1634,$,$); -#1636=IFCCLASSIFICATIONREFERENCE($,'23-11 15 11 11','Sheeting Geotextiles',#1635,$,$); -#1637=IFCCLASSIFICATIONREFERENCE($,'23-11 15 11 13','Sheeting Geogrids',#1635,$,$); -#1638=IFCCLASSIFICATIONREFERENCE($,'23-11 15 11 15','Sheeting Geomembranes',#1635,$,$); -#1639=IFCCLASSIFICATIONREFERENCE($,'23-11 15 11 17','Sheeting Geocomposites',#1635,$,$); -#1640=IFCCLASSIFICATIONREFERENCE($,'23-11 15 11 19','Sheeting Mulch Control Netting',#1635,$,$); -#1641=IFCCLASSIFICATIONREFERENCE($,'23-11 15 11 21','Sheeting Synthetic Erosion Controls',#1635,$,$); -#1642=IFCCLASSIFICATIONREFERENCE($,'23-11 15 11 23','Sheeting Re vegetation Mats',#1635,$,$); -#1643=IFCCLASSIFICATIONREFERENCE($,'23-11 15 11 25','Sheeting Turf Reinforcement Mats',#1635,$,$); -#1644=IFCCLASSIFICATIONREFERENCE($,'23-11 15 13','Revetments',#1634,$,$); -#1645=IFCCLASSIFICATIONREFERENCE($,'23-11 15 13 11','Revetment Soil Blankets',#1644,$,$); -#1646=IFCCLASSIFICATIONREFERENCE($,'23-11 15 13 13','Pool Revetments',#1644,$,$); -#1647=IFCCLASSIFICATIONREFERENCE($,'23-11 15 13 15','Trench Revetments',#1644,$,$); -#1648=IFCCLASSIFICATIONREFERENCE($,'23-11 15 13 17','Revetment Rock Linings',#1644,$,$); -#1649=IFCCLASSIFICATIONREFERENCE($,'23-11 15 13 19','Revetment Ripraps',#1644,$,$); -#1650=IFCCLASSIFICATIONREFERENCE($,'23-11 17 00','Retention Structures',#1605,$,$); -#1651=IFCCLASSIFICATIONREFERENCE($,'23-11 17 11','Sheet Piles',#1650,$,$); -#1652=IFCCLASSIFICATIONREFERENCE($,'23-11 17 13','Retaining Walls',#1650,$,$); -#1653=IFCCLASSIFICATIONREFERENCE($,'23-11 17 13 11','Retaining Diaphragm Walls',#1652,$,$); -#1654=IFCCLASSIFICATIONREFERENCE($,'23-11 17 13 11 11','Retaining Slurry Wall Membranes',#1653,$,$); -#1655=IFCCLASSIFICATIONREFERENCE($,'23-11 17 13 13','Continuous Retaining Walls',#1652,$,$); -#1656=IFCCLASSIFICATIONREFERENCE($,'23-11 17 13 15','Retaining Crib Walls',#1652,$,$); -#1657=IFCCLASSIFICATIONREFERENCE($,'23-11 17 15','Gabions',#1650,$,$); -#1658=IFCCLASSIFICATIONREFERENCE($,'23-11 17 17','Fascines',#1650,$,$); -#1659=IFCCLASSIFICATIONREFERENCE($,'23-11 19 00','Slide and Avalanche Protection',#1605,$,$); -#1660=IFCCLASSIFICATIONREFERENCE($,'23-11 19 11','Bolt Down Snow Fences',#1659,$,$); -#1661=IFCCLASSIFICATIONREFERENCE($,'23-11 19 13','Clamp on Equipment',#1659,$,$); -#1662=IFCCLASSIFICATIONREFERENCE($,'23-11 21 00','Pavements',#1605,$,$); -#1663=IFCCLASSIFICATIONREFERENCE($,'23-11 21 11','Porous Paving',#1662,$,$); -#1664=IFCCLASSIFICATIONREFERENCE($,'23-11 21 13','Roadways',#1662,$,$); -#1665=IFCCLASSIFICATIONREFERENCE($,'23-11 21 13 11','Portable Roadways',#1664,$,$); -#1666=IFCCLASSIFICATIONREFERENCE($,'23-11 21 13 13','Roadway Surfacing',#1664,$,$); -#1667=IFCCLASSIFICATIONREFERENCE($,'23-11 21 13 13 11','Roadway Antiskid Texturing',#1666,$,$); -#1668=IFCCLASSIFICATIONREFERENCE($,'23-11 21 13 15','Detectable Warning Surfaces for Roadways',#1664,$,$); -#1669=IFCCLASSIFICATIONREFERENCE($,'23-11 21 13 15 11','Crosswalks',#1668,$,$); -#1670=IFCCLASSIFICATIONREFERENCE($,'23-11 21 13 15 13','Warning Tiles',#1668,$,$); -#1671=IFCCLASSIFICATIONREFERENCE($,'23-11 21 15','Runways',#1662,$,$); -#1672=IFCCLASSIFICATIONREFERENCE($,'23-11 21 15 11','Portable Runway',#1671,$,$); -#1673=IFCCLASSIFICATIONREFERENCE($,'23-11 21 15 13','Helicopter Landing Pads',#1671,$,$); -#1674=IFCCLASSIFICATIONREFERENCE($,'23-11 21 15 15','Runway Surfacing',#1671,$,$); -#1675=IFCCLASSIFICATIONREFERENCE($,'23-11 21 15 15 11','Runway Antiskid Texturing',#1674,$,$); -#1676=IFCCLASSIFICATIONREFERENCE($,'23-11 21 17','Paving Blocks',#1662,$,$); -#1677=IFCCLASSIFICATIONREFERENCE($,'23-11 21 17 11','Unit Pavers',#1676,$,$); -#1678=IFCCLASSIFICATIONREFERENCE($,'23-11 21 17 11 11','Asphalt Block Pavers',#1677,$,$); -#1679=IFCCLASSIFICATIONREFERENCE($,'23-11 21 17 11 13','Brick Pavers',#1677,$,$); -#1680=IFCCLASSIFICATIONREFERENCE($,'23-11 21 17 11 15','Interlocking Precast Concrete Pavers',#1677,$,$); -#1681=IFCCLASSIFICATIONREFERENCE($,'23-11 21 17 11 17','Precast Concrete Pavers',#1677,$,$); -#1682=IFCCLASSIFICATIONREFERENCE($,'23-11 21 17 11 19','Pressed Pavers',#1677,$,$); -#1683=IFCCLASSIFICATIONREFERENCE($,'23-11 21 17 11 21','Stone Pavers',#1677,$,$); -#1684=IFCCLASSIFICATIONREFERENCE($,'23-11 21 19','Pavement Slabs',#1662,$,$); -#1685=IFCCLASSIFICATIONREFERENCE($,'23-11 21 21','Pavement Drainage',#1662,$,$); -#1686=IFCCLASSIFICATIONREFERENCE($,'23-11 21 21 11','Culverts',#1685,$,$); -#1687=IFCCLASSIFICATIONREFERENCE($,'23-11 21 21 11 11','Pipe Culverts',#1686,$,$); -#1688=IFCCLASSIFICATIONREFERENCE($,'23-11 21 21 11 11 11','Metal Pipe Arch Culverts',#1687,$,$); -#1689=IFCCLASSIFICATIONREFERENCE($,'23-11 21 21 11 13','Concrete Culverts',#1686,$,$); -#1690=IFCCLASSIFICATIONREFERENCE($,'23-11 21 21 11 13 11','Concrete Arch Buried Bridge Culverts',#1689,$,$); -#1691=IFCCLASSIFICATIONREFERENCE($,'23-11 21 21 11 13 13','Concrete Arch Culverts',#1689,$,$); -#1692=IFCCLASSIFICATIONREFERENCE($,'23-11 21 21 11 13 15','Concrete Box Culverts',#1689,$,$); -#1693=IFCCLASSIFICATIONREFERENCE($,'23-11 21 21 11 13 17','Concrete Rigid Frame Culverts',#1689,$,$); -#1694=IFCCLASSIFICATIONREFERENCE($,'23-11 21 21 13','Catch Basins',#1685,$,$); -#1695=IFCCLASSIFICATIONREFERENCE($,'23-11 21 21 15','Channels',#1685,$,$); -#1696=IFCCLASSIFICATIONREFERENCE($,'23-11 21 21 17','Cleanouts',#1685,$,$); -#1697=IFCCLASSIFICATIONREFERENCE($,'23-11 23 00','Parking Controls',#1605,$,$); -#1698=IFCCLASSIFICATIONREFERENCE($,'23-11 23 11','Parking Meters',#1697,$,$); -#1699=IFCCLASSIFICATIONREFERENCE($,'23-11 23 13','Parking Ticket Dispensers',#1697,$,$); -#1700=IFCCLASSIFICATIONREFERENCE($,'23-11 23 15','Parking Coin Machine Units',#1697,$,$); -#1701=IFCCLASSIFICATIONREFERENCE($,'23-11 23 17','Parking Key and Card Control Units',#1697,$,$); -#1702=IFCCLASSIFICATIONREFERENCE($,'23-11 23 19','Parking Gates',#1697,$,$); -#1703=IFCCLASSIFICATIONREFERENCE($,'23-11 23 21','Parking Dividers',#1697,$,$); -#1704=IFCCLASSIFICATIONREFERENCE($,'23-11 23 23','Parking Signs',#1697,$,$); -#1705=IFCCLASSIFICATIONREFERENCE($,'23-11 23 23 11','Handicap Parking Signs',#1704,$,$); -#1706=IFCCLASSIFICATIONREFERENCE($,'23-11 23 23 13','Parking Time Zone Signs',#1704,$,$); -#1707=IFCCLASSIFICATIONREFERENCE($,'23-11 23 23 15','Parking Tow Away Signs',#1704,$,$); -#1708=IFCCLASSIFICATIONREFERENCE($,'23-11 25 00','Site Barrier Products',#1605,$,$); -#1709=IFCCLASSIFICATIONREFERENCE($,'23-11 25 11','Perimeter Entry Devices',#1708,$,$); -#1710=IFCCLASSIFICATIONREFERENCE($,'23-11 25 11 11','Anti Ram Wedge Barriers',#1709,$,$); -#1711=IFCCLASSIFICATIONREFERENCE($,'23-11 25 13','Perimeter Walls',#1708,$,$); -#1712=IFCCLASSIFICATIONREFERENCE($,'23-11 25 13 11','Precast Perimeter Concrete Panel Perimeter Walls',#1711,$,$); -#1713=IFCCLASSIFICATIONREFERENCE($,'23-11 25 13 13','Precast Perimeter Post Perimeter Walls',#1711,$,$); -#1714=IFCCLASSIFICATIONREFERENCE($,'23-11 25 15','Perimeter Gates',#1708,$,$); -#1715=IFCCLASSIFICATIONREFERENCE($,'23-11 25 15 11','Drop Arm Gates',#1714,$,$); -#1716=IFCCLASSIFICATIONREFERENCE($,'23-11 25 15 11 11','Anti Ram Drop Arm Gates',#1715,$,$); -#1717=IFCCLASSIFICATIONREFERENCE($,'23-11 25 15 13','Rolling Gates',#1714,$,$); -#1718=IFCCLASSIFICATIONREFERENCE($,'23-11 25 15 15','Sliding Gates',#1714,$,$); -#1719=IFCCLASSIFICATIONREFERENCE($,'23-11 25 15 15 11','Anti Ram Sliding Gates',#1718,$,$); -#1720=IFCCLASSIFICATIONREFERENCE($,'23-11 25 15 15 13','Anti Climb Sliding Gates',#1718,$,$); -#1721=IFCCLASSIFICATIONREFERENCE($,'23-11 25 15 17','Swinging Gates',#1714,$,$); -#1722=IFCCLASSIFICATIONREFERENCE($,'23-11 25 15 19','Folding Gates',#1714,$,$); -#1723=IFCCLASSIFICATIONREFERENCE($,'23-11 25 17','Gate Hardware',#1708,$,$); -#1724=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19','Fences',#1708,$,$); -#1725=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 11','Barbed Wire Fences',#1724,$,$); -#1726=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 13','Concertina Wire Fences',#1724,$,$); -#1727=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 15','Composite Fences',#1724,$,$); -#1728=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 17','Ornamental Metal Fences',#1724,$,$); -#1729=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 19','Chain Link Metal Fences',#1724,$,$); -#1730=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 21','Panel Fences',#1724,$,$); -#1731=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 23','Plastic Fences',#1724,$,$); -#1732=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 25','Post Fences',#1724,$,$); -#1733=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 27','Rail Fences',#1724,$,$); -#1734=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 29','Razor Wire Fences',#1724,$,$); -#1735=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 31','Wood Fences',#1724,$,$); -#1736=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 33','Fencing Fabrics',#1724,$,$); -#1737=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 35','Fencing Accessories',#1724,$,$); -#1738=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 35 11','Barbed Wire',#1737,$,$); -#1739=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 35 13','Concertina Wire',#1737,$,$); -#1740=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 35 15','Fence Posts',#1737,$,$); -#1741=IFCCLASSIFICATIONREFERENCE($,'23-11 27 00','Landscaping',#1605,$,$); -#1742=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11','Plant Maintenance and Preparation Products',#1741,$,$); -#1743=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 11','Topsoil',#1742,$,$); -#1744=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 11 11','Loam',#1743,$,$); -#1745=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 11 13','Peat Soil',#1743,$,$); -#1746=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 13','Soil Fertilizers',#1742,$,$); -#1747=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 15','Soil Herbicides',#1742,$,$); -#1748=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 15 11','Combined Soil Fertilizer and Herbicides',#1747,$,$); -#1749=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 17','Mulch',#1742,$,$); -#1750=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 19','Soil Mats',#1742,$,$); -#1751=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 21','Plant Netting',#1742,$,$); -#1752=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 23','Landscaping Stakes',#1742,$,$); -#1753=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 25','Landscaping Blankets',#1742,$,$); -#1754=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 27','Landscaping Ground Covers',#1742,$,$); -#1755=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 29','Landscaping Forms',#1742,$,$); -#1756=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 31','Landscaping Stabilizers',#1742,$,$); -#1757=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 33','Lime',#1742,$,$); -#1758=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 35','Mowing Equipment',#1742,$,$); -#1759=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 35 11','Lawnmowers',#1758,$,$); -#1760=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 35 13','Garden Tractors',#1758,$,$); -#1761=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 37','Pruning Equipment',#1742,$,$); -#1762=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 39','Watering Equipment',#1742,$,$); -#1763=IFCCLASSIFICATIONREFERENCE($,'23-11 27 13','Planting Accessories',#1741,$,$); -#1764=IFCCLASSIFICATIONREFERENCE($,'23-11 27 13 11','Landscaping Edging',#1763,$,$); -#1765=IFCCLASSIFICATIONREFERENCE($,'23-11 27 13 13','Landscape Timbers',#1763,$,$); -#1766=IFCCLASSIFICATIONREFERENCE($,'23-11 27 13 15','Landscape Stone',#1763,$,$); -#1767=IFCCLASSIFICATIONREFERENCE($,'23-11 27 13 15 11','Boulders',#1766,$,$); -#1768=IFCCLASSIFICATIONREFERENCE($,'23-11 27 13 17','Planters',#1763,$,$); -#1769=IFCCLASSIFICATIONREFERENCE($,'23-11 27 13 19','Tree Grates',#1763,$,$); -#1770=IFCCLASSIFICATIONREFERENCE($,'23-11 27 13 21','Tree Grids',#1763,$,$); -#1771=IFCCLASSIFICATIONREFERENCE($,'23-11 27 13 23','Tree Guards',#1763,$,$); -#1772=IFCCLASSIFICATIONREFERENCE($,'23-11 27 13 25','Plant Tubs',#1763,$,$); -#1773=IFCCLASSIFICATIONREFERENCE($,'23-11 27 15','Irrigation Equipment',#1741,$,$); -#1774=IFCCLASSIFICATIONREFERENCE($,'23-11 27 15 11','Irrigation Sprinklers',#1773,$,$); -#1775=IFCCLASSIFICATIONREFERENCE($,'23-11 27 15 11 11','Installed Sprinkler Heads',#1774,$,$); -#1776=IFCCLASSIFICATIONREFERENCE($,'23-11 27 15 11 13','Portable Lawn Sprinklers',#1774,$,$); -#1777=IFCCLASSIFICATIONREFERENCE($,'23-11 27 15 13','Irrigation Hoses',#1773,$,$); -#1778=IFCCLASSIFICATIONREFERENCE($,'23-11 27 15 13 11','Irrigation Weep Hoses',#1777,$,$); -#1779=IFCCLASSIFICATIONREFERENCE($,'23-11 27 17','Lawns and Grasses',#1741,$,$); -#1780=IFCCLASSIFICATIONREFERENCE($,'23-11 27 17 11','Hydro Mulch',#1779,$,$); -#1781=IFCCLASSIFICATIONREFERENCE($,'23-11 27 17 13','Grass Plugs',#1779,$,$); -#1782=IFCCLASSIFICATIONREFERENCE($,'23-11 27 17 15','Grass Seeds and Soil Supplements',#1779,$,$); -#1783=IFCCLASSIFICATIONREFERENCE($,'23-11 27 17 17','Sod',#1779,$,$); -#1784=IFCCLASSIFICATIONREFERENCE($,'23-11 27 19','Plants',#1741,$,$); -#1785=IFCCLASSIFICATIONREFERENCE($,'23-11 27 19 11','Shrubs',#1784,$,$); -#1786=IFCCLASSIFICATIONREFERENCE($,'23-11 27 19 13','Trees',#1784,$,$); -#1787=IFCCLASSIFICATIONREFERENCE($,'23-11 27 19 15','Plants',#1784,$,$); -#1788=IFCCLASSIFICATIONREFERENCE($,'23-11 27 19 17','Plant Bulbs',#1784,$,$); -#1789=IFCCLASSIFICATIONREFERENCE($,'23-11 27 19 19','Floral Plant',#1784,$,$); -#1790=IFCCLASSIFICATIONREFERENCE($,'23-11 27 19 21','Non Flowering Plant',#1784,$,$); -#1791=IFCCLASSIFICATIONREFERENCE($,'23-11 27 21','Pond Equipment',#1741,$,$); -#1792=IFCCLASSIFICATIONREFERENCE($,'23-11 27 21 11','Pond Liners',#1791,$,$); -#1793=IFCCLASSIFICATIONREFERENCE($,'23-11 27 21 13','Pond Filters',#1791,$,$); -#1794=IFCCLASSIFICATIONREFERENCE($,'23-11 29 00','Site Furnishings',#1605,$,$); -#1795=IFCCLASSIFICATIONREFERENCE($,'23-11 29 11','Bicycle Racks and Shelters',#1794,$,$); -#1796=IFCCLASSIFICATIONREFERENCE($,'23-11 29 11 11','Bicycle Racks',#1795,$,$); -#1797=IFCCLASSIFICATIONREFERENCE($,'23-11 29 11 13','Bicycle Shelters',#1795,$,$); -#1798=IFCCLASSIFICATIONREFERENCE($,'23-11 29 11 15','Bicycle Lockers',#1795,$,$); -#1799=IFCCLASSIFICATIONREFERENCE($,'23-11 29 13','Exterior Seating',#1794,$,$); -#1800=IFCCLASSIFICATIONREFERENCE($,'23-11 29 13 11','Exterior Benches',#1799,$,$); -#1801=IFCCLASSIFICATIONREFERENCE($,'23-11 29 13 13','Exterior Chairs',#1799,$,$); -#1802=IFCCLASSIFICATIONREFERENCE($,'23-11 29 15','Exterior Tables',#1794,$,$); -#1803=IFCCLASSIFICATIONREFERENCE($,'23-11 29 17','Patio Furniture',#1794,$,$); -#1804=IFCCLASSIFICATIONREFERENCE($,'23-11 29 17 11','Patio Seating',#1803,$,$); -#1805=IFCCLASSIFICATIONREFERENCE($,'23-11 29 17 11 11','Patio Chairs',#1804,$,$); -#1806=IFCCLASSIFICATIONREFERENCE($,'23-11 29 17 11 13','Patio Benches',#1804,$,$); -#1807=IFCCLASSIFICATIONREFERENCE($,'23-11 29 17 11 15','Patio Chaise Lounges',#1804,$,$); -#1808=IFCCLASSIFICATIONREFERENCE($,'23-11 29 17 11 17','Patio Sofas',#1804,$,$); -#1809=IFCCLASSIFICATIONREFERENCE($,'23-11 29 17 13','Patio Tables',#1803,$,$); -#1810=IFCCLASSIFICATIONREFERENCE($,'23-11 29 17 13 11','Patio Dining Tables',#1809,$,$); -#1811=IFCCLASSIFICATIONREFERENCE($,'23-11 29 17 13 13','Patio Sofa Tables',#1809,$,$); -#1812=IFCCLASSIFICATIONREFERENCE($,'23-11 29 19','Exterior Trash Receptacles',#1794,$,$); -#1813=IFCCLASSIFICATIONREFERENCE($,'23-11 29 19 11','Exterior Wood Trash Receptacles',#1812,$,$); -#1814=IFCCLASSIFICATIONREFERENCE($,'23-11 29 19 13','Exterior Concrete Trash Receptacles',#1812,$,$); -#1815=IFCCLASSIFICATIONREFERENCE($,'23-11 29 19 15','Exterior Metal Trash Receptacles',#1812,$,$); -#1816=IFCCLASSIFICATIONREFERENCE($,'23-11 29 21','Exterior Specialties',#1794,$,$); -#1817=IFCCLASSIFICATIONREFERENCE($,'23-11 29 21 11','Sundials',#1816,$,$); -#1818=IFCCLASSIFICATIONREFERENCE($,'23-11 29 21 13','Garden Ornaments',#1816,$,$); -#1819=IFCCLASSIFICATIONREFERENCE($,'23-11 29 21 15','Bird Houses',#1816,$,$); -#1820=IFCCLASSIFICATIONREFERENCE($,'23-11 29 21 17','Bird Feeders',#1816,$,$); -#1821=IFCCLASSIFICATIONREFERENCE($,'23-11 29 21 19','Bird Baths',#1816,$,$); -#1822=IFCCLASSIFICATIONREFERENCE($,'23-11 29 23','Exterior Storage Structures',#1794,$,$); -#1823=IFCCLASSIFICATIONREFERENCE($,'23-11 29 23 11','Storage Sheds',#1822,$,$); -#1824=IFCCLASSIFICATIONREFERENCE($,'23-11 29 23 13','Barns',#1822,$,$); -#1825=IFCCLASSIFICATIONREFERENCE($,'23-11 29 25','Flagpoles',#1794,$,$); -#1826=IFCCLASSIFICATIONREFERENCE($,'23-11 29 25 11','Automatic Flagpoles',#1825,$,$); -#1827=IFCCLASSIFICATIONREFERENCE($,'23-11 29 25 13','Ground Set Flagpoles',#1825,$,$); -#1828=IFCCLASSIFICATIONREFERENCE($,'23-11 29 25 15','Nautical Flagpoles',#1825,$,$); -#1829=IFCCLASSIFICATIONREFERENCE($,'23-11 29 25 17','Wall Mounted Flagpoles',#1825,$,$); -#1830=IFCCLASSIFICATIONREFERENCE($,'23-11 29 27','Exterior Fountains',#1794,$,$); -#1831=IFCCLASSIFICATIONREFERENCE($,'23-11 29 27 11','Exterior Ornamental Fountains',#1830,$,$); -#1832=IFCCLASSIFICATIONREFERENCE($,'23-11 29 29','Memorials and Statuary',#1794,$,$); -#1833=IFCCLASSIFICATIONREFERENCE($,'23-11 29 31','Monuments',#1794,$,$); -#1834=IFCCLASSIFICATIONREFERENCE($,'23-11 29 33','Exterior Directional Signs',#1794,$,$); -#1835=IFCCLASSIFICATIONREFERENCE($,'23-11 29 33 11','Finger Post Signs',#1834,$,$); -#1836=IFCCLASSIFICATIONREFERENCE($,'23-11 29 33 13','Street Nameplates',#1834,$,$); -#1837=IFCCLASSIFICATIONREFERENCE($,'23-11 29 33 15','Illuminated Directional Signs',#1834,$,$); -#1838=IFCCLASSIFICATIONREFERENCE($,'23-11 29 33 17','Directional Sign Markers',#1834,$,$); -#1839=IFCCLASSIFICATIONREFERENCE($,'23-11 29 35','Bollards',#1794,$,$); -#1840=IFCCLASSIFICATIONREFERENCE($,'23-11 29 35 11','Active Anti Ram Bollards',#1839,$,$); -#1841=IFCCLASSIFICATIONREFERENCE($,'23-11 29 35 13','Passive Anti Ram Bollards',#1839,$,$); -#1842=IFCCLASSIFICATIONREFERENCE($,'23-11 29 35 15','Architectural Bollards',#1839,$,$); -#1843=IFCCLASSIFICATIONREFERENCE($,'23-11 29 37','Public Lighting Columns',#1794,$,$); -#1844=IFCCLASSIFICATIONREFERENCE($,'23-11 31 00','Athletic and Recreational Surfaces',#1605,$,$); -#1845=IFCCLASSIFICATIONREFERENCE($,'23-11 31 11','Sports Field Surfacing',#1844,$,$); -#1846=IFCCLASSIFICATIONREFERENCE($,'23-11 31 13','Playground Surfaces',#1844,$,$); -#1847=IFCCLASSIFICATIONREFERENCE($,'23-13 00 00','Structural and Exterior Enclosure Products',#1604,$,$); -#1848=IFCCLASSIFICATIONREFERENCE($,'23-13 11 00','Loose Granular Fills, Aggregates, Chips, and Fibers',#1847,$,$); -#1849=IFCCLASSIFICATIONREFERENCE($,'23-13 11 11','Powder Fillers',#1848,$,$); -#1850=IFCCLASSIFICATIONREFERENCE($,'23-13 11 11 11','Mineral Powder Fillers',#1849,$,$); -#1851=IFCCLASSIFICATIONREFERENCE($,'23-13 11 11 13','Metal Powder Fillers',#1849,$,$); -#1852=IFCCLASSIFICATIONREFERENCE($,'23-13 11 11 15','Synthetic Powder Fillers',#1849,$,$); -#1853=IFCCLASSIFICATIONREFERENCE($,'23-13 11 11 17','Residue Powder Fillers',#1849,$,$); -#1854=IFCCLASSIFICATIONREFERENCE($,'23-13 11 13','Aggregates',#1848,$,$); -#1855=IFCCLASSIFICATIONREFERENCE($,'23-13 11 13 11','Dense Fills and Aggregates',#1854,$,$); -#1856=IFCCLASSIFICATIONREFERENCE($,'23-13 11 13 13','Lightweight Fills and Aggregates',#1854,$,$); -#1857=IFCCLASSIFICATIONREFERENCE($,'23-13 11 13 15','Heavyweight Fills and Aggregates',#1854,$,$); -#1858=IFCCLASSIFICATIONREFERENCE($,'23-13 11 15','Fibers and Shavings',#1848,$,$); -#1859=IFCCLASSIFICATIONREFERENCE($,'23-13 11 15 11','Mineral Fibers and Shavings',#1858,$,$); -#1860=IFCCLASSIFICATIONREFERENCE($,'23-13 11 15 13','Vegetable Fibers and Shavings',#1858,$,$); -#1861=IFCCLASSIFICATIONREFERENCE($,'23-13 11 15 15','Synthetic Fibers and Shavings',#1858,$,$); -#1862=IFCCLASSIFICATIONREFERENCE($,'23-13 11 15 17','Other Fibers and Shavings',#1858,$,$); -#1863=IFCCLASSIFICATIONREFERENCE($,'23-13 13 00','Binding Agents and Admixtures',#1847,$,$); -#1864=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11','Binding Agents',#1863,$,$); -#1865=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11 11','Cement',#1864,$,$); -#1866=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11 11 11','Standard Cement',#1865,$,$); -#1867=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11 11 13','Specialized Cement',#1865,$,$); -#1868=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11 11 13 11','High Sulfate Resistant Cement',#1867,$,$); -#1869=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11 11 13 13','Low Alkali Cement',#1867,$,$); -#1870=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11 11 13 15','Low Heat Cement',#1867,$,$); -#1871=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11 11 13 17','Alumina Cement',#1867,$,$); -#1872=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11 13','Lime',#1864,$,$); -#1873=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11 13 11','Hydraulic Lime',#1872,$,$); -#1874=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11 13 13','Air Hardening Lime',#1872,$,$); -#1875=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11 15','Bitumen Asphalt',#1864,$,$); -#1876=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11 17','Resinous Binders',#1864,$,$); -#1877=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11 19','Gypsum',#1864,$,$); -#1878=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13','Cement Admixtures',#1863,$,$); -#1879=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 11','Cement Plasticizing Agents',#1878,$,$); -#1880=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 13','Cement Water Retaining Agents',#1878,$,$); -#1881=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 15','Cement Air Entraining Agents',#1878,$,$); -#1882=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 17','Cement Gas Generating Agents',#1878,$,$); -#1883=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 19','Cement Setting Retarders',#1878,$,$); -#1884=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 21','Cement Setting Accelerators',#1878,$,$); -#1885=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 23','Cement Frostproofing Agents',#1878,$,$); -#1886=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 25','Cement Waterproofing Agents',#1878,$,$); -#1887=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 27','Cement Coloring Agents',#1878,$,$); -#1888=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 29','Cement Admixtures for Injections',#1878,$,$); -#1889=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 31','Cement Admixtures for Projections',#1878,$,$); -#1890=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 33','Cement Adherence Proofing Agents',#1878,$,$); -#1891=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 35','Cement Bonding Agents',#1878,$,$); -#1892=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 37','Cement Replacements',#1878,$,$); -#1893=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 39','Other Cement Admixtures',#1878,$,$); -#1894=IFCCLASSIFICATIONREFERENCE($,'23-13 13 15','Gypsum Admixtures',#1863,$,$); -#1895=IFCCLASSIFICATIONREFERENCE($,'23-13 15 00','Mixtures',#1847,$,$); -#1896=IFCCLASSIFICATIONREFERENCE($,'23-13 15 11','Concretes',#1895,$,$); -#1897=IFCCLASSIFICATIONREFERENCE($,'23-13 15 11 11','Cementitious Concretes',#1896,$,$); -#1898=IFCCLASSIFICATIONREFERENCE($,'23-13 15 11 13','Resinous Concretes',#1896,$,$); -#1899=IFCCLASSIFICATIONREFERENCE($,'23-13 15 11 15','Hydrocarbon Concretes',#1896,$,$); -#1900=IFCCLASSIFICATIONREFERENCE($,'23-13 15 11 17','Low Density Concretes',#1896,$,$); -#1901=IFCCLASSIFICATIONREFERENCE($,'23-13 15 13','Mortars',#1895,$,$); -#1902=IFCCLASSIFICATIONREFERENCE($,'23-13 15 13 11','Portland Cement Lime Mortars',#1901,$,$); -#1903=IFCCLASSIFICATIONREFERENCE($,'23-13 15 13 13','Masonry Cement Mortars',#1901,$,$); -#1904=IFCCLASSIFICATIONREFERENCE($,'23-13 15 13 15','Mortar Cements',#1901,$,$); -#1905=IFCCLASSIFICATIONREFERENCE($,'23-13 15 13 17','Gypsum Based Mortars',#1901,$,$); -#1906=IFCCLASSIFICATIONREFERENCE($,'23-13 15 13 19','Resinous Mortar',#1901,$,$); -#1907=IFCCLASSIFICATIONREFERENCE($,'23-13 15 13 21','Chemical Resistant Mortar',#1901,$,$); -#1908=IFCCLASSIFICATIONREFERENCE($,'23-13 15 13 23','Refractory Mortar',#1901,$,$); -#1909=IFCCLASSIFICATIONREFERENCE($,'23-13 15 13 25','Premixed Mortar',#1901,$,$); -#1910=IFCCLASSIFICATIONREFERENCE($,'23-13 15 13 27','Surface Bonding Mortar',#1901,$,$); -#1911=IFCCLASSIFICATIONREFERENCE($,'23-13 15 13 29','Mortar Pigments',#1901,$,$); -#1912=IFCCLASSIFICATIONREFERENCE($,'23-13 15 15','Grouts',#1895,$,$); -#1913=IFCCLASSIFICATIONREFERENCE($,'23-13 15 15 11','Concrete Grouts',#1912,$,$); -#1914=IFCCLASSIFICATIONREFERENCE($,'23-13 15 15 11 11','Shrink Resistant Concrete Grouts',#1913,$,$); -#1915=IFCCLASSIFICATIONREFERENCE($,'23-13 15 15 11 13','Catalyzed Metallic Concrete Grouts',#1913,$,$); -#1916=IFCCLASSIFICATIONREFERENCE($,'23-13 15 15 11 15','Epoxy Concrete Grouts',#1913,$,$); -#1917=IFCCLASSIFICATIONREFERENCE($,'23-13 15 15 11 17','Nonmetallic Concrete Grouts',#1913,$,$); -#1918=IFCCLASSIFICATIONREFERENCE($,'23-13 15 15 13','Masonry Grouts',#1912,$,$); -#1919=IFCCLASSIFICATIONREFERENCE($,'23-13 15 15 13 11','Chemical Resistant Masonry Grouts',#1918,$,$); -#1920=IFCCLASSIFICATIONREFERENCE($,'23-13 17 00','Profiles',#1847,$,$); -#1921=IFCCLASSIFICATIONREFERENCE($,'23-13 17 11','Rigid Profiles',#1920,$,$); -#1922=IFCCLASSIFICATIONREFERENCE($,'23-13 17 11 11','Ferrous Metal Rigid Profiles',#1921,$,$); -#1923=IFCCLASSIFICATIONREFERENCE($,'23-13 17 11 13','Non Ferrous Metal Rigid Profiles',#1921,$,$); -#1924=IFCCLASSIFICATIONREFERENCE($,'23-13 17 11 15','Wood Rigid Profiles',#1921,$,$); -#1925=IFCCLASSIFICATIONREFERENCE($,'23-13 17 11 15 11','Lumber Rigid Profiles',#1924,$,$); -#1926=IFCCLASSIFICATIONREFERENCE($,'23-13 17 11 15 11 11','Hardwood Rigid Profiles',#1925,$,$); -#1927=IFCCLASSIFICATIONREFERENCE($,'23-13 17 11 15 11 13','Softwood Rigid Profiles',#1925,$,$); -#1928=IFCCLASSIFICATIONREFERENCE($,'23-13 17 11 15 11 15','Laminated Rigid Profiles',#1925,$,$); -#1929=IFCCLASSIFICATIONREFERENCE($,'23-13 17 11 15 13','Non Structural Heavy Timber Rigid Profiles',#1924,$,$); -#1930=IFCCLASSIFICATIONREFERENCE($,'23-13 17 11 17','Plastic Rigid Profiles',#1921,$,$); -#1931=IFCCLASSIFICATIONREFERENCE($,'23-13 17 11 19','Composite Rigid Profiles',#1921,$,$); -#1932=IFCCLASSIFICATIONREFERENCE($,'23-13 17 13','Flexible Profiles',#1920,$,$); -#1933=IFCCLASSIFICATIONREFERENCE($,'23-13 17 13 11','Plastic Flexible Profiles',#1932,$,$); -#1934=IFCCLASSIFICATIONREFERENCE($,'23-13 17 13 13','Rubber Flexible Profiles',#1932,$,$); -#1935=IFCCLASSIFICATIONREFERENCE($,'23-13 17 13 13 11','Natural Rubber Flexible Profiles',#1934,$,$); -#1936=IFCCLASSIFICATIONREFERENCE($,'23-13 17 13 13 13','Butyl Flexible Profiles',#1934,$,$); -#1937=IFCCLASSIFICATIONREFERENCE($,'23-13 17 13 13 15','Neoprene Flexible Profiles',#1934,$,$); -#1938=IFCCLASSIFICATIONREFERENCE($,'23-13 17 13 13 17','Silicone Flexible Profiles',#1934,$,$); -#1939=IFCCLASSIFICATIONREFERENCE($,'23-13 17 13 13 19','Polysulfide Flexible Profiles',#1934,$,$); -#1940=IFCCLASSIFICATIONREFERENCE($,'23-13 17 15','Precast Profiles',#1920,$,$); -#1941=IFCCLASSIFICATIONREFERENCE($,'23-13 17 15 11','Precast Hollow Core Sheets',#1940,$,$); -#1942=IFCCLASSIFICATIONREFERENCE($,'23-13 17 15 13','Precast Tees',#1940,$,$); -#1943=IFCCLASSIFICATIONREFERENCE($,'23-13 17 15 15','Precast Double Tees',#1940,$,$); -#1944=IFCCLASSIFICATIONREFERENCE($,'23-13 17 17','Lath',#1920,$,$); -#1945=IFCCLASSIFICATIONREFERENCE($,'23-13 17 17 11','Gypsum Lath',#1944,$,$); -#1946=IFCCLASSIFICATIONREFERENCE($,'23-13 17 17 13','Lead Lined Lath',#1944,$,$); -#1947=IFCCLASSIFICATIONREFERENCE($,'23-13 17 17 15','Metal Lath',#1944,$,$); -#1948=IFCCLASSIFICATIONREFERENCE($,'23-13 17 17 17','Veneer Plaster Base Lath',#1944,$,$); -#1949=IFCCLASSIFICATIONREFERENCE($,'23-13 17 17 19','Wood Lath',#1944,$,$); -#1950=IFCCLASSIFICATIONREFERENCE($,'23-13 19 00','Sheets, Boards, and Slabs',#1847,$,$); -#1951=IFCCLASSIFICATIONREFERENCE($,'23-13 19 11','Thin Flexible Sheets',#1950,$,$); -#1952=IFCCLASSIFICATIONREFERENCE($,'23-13 19 11 11','Thin Sheets',#1951,$,$); -#1953=IFCCLASSIFICATIONREFERENCE($,'23-13 19 11 11 11','Thin Metal Sheets',#1952,$,$); -#1954=IFCCLASSIFICATIONREFERENCE($,'23-13 19 11 11 13','Thin Wood Sheets',#1952,$,$); -#1955=IFCCLASSIFICATIONREFERENCE($,'23-13 19 11 11 15','Building Papers',#1952,$,$); -#1956=IFCCLASSIFICATIONREFERENCE($,'23-13 19 11 11 17','Thin Plastic Sheets',#1952,$,$); -#1957=IFCCLASSIFICATIONREFERENCE($,'23-13 19 11 11 19','Thin Rubber Sheets',#1952,$,$); -#1958=IFCCLASSIFICATIONREFERENCE($,'23-13 19 11 13','Textiles',#1951,$,$); -#1959=IFCCLASSIFICATIONREFERENCE($,'23-13 19 11 15','Mesh for General Use',#1951,$,$); -#1960=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13','Rigid Sheets, Slabs, Plates',#1950,$,$); -#1961=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 11','Solid Sheets',#1960,$,$); -#1962=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 11 11','Solid Stone Sheets',#1961,$,$); -#1963=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 11 13','Solid Cementitious Sheets',#1961,$,$); -#1964=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 11 15','Solid Mineral Sheets',#1961,$,$); -#1965=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 11 17','Solid Glass Sheets',#1961,$,$); -#1966=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 11 19','Solid Metal Sheets',#1961,$,$); -#1967=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 11 21','Solid Wood Based Sheets',#1961,$,$); -#1968=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 11 23','Solid Plastic Sheets',#1961,$,$); -#1969=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 11 25','Solid Resin Sheets',#1961,$,$); -#1970=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 11 27','Solid Fiberglass Sheets',#1961,$,$); -#1971=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 13','Hollow Core Sheets',#1960,$,$); -#1972=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 13 11','Wood Based Hollow Core Sheets',#1971,$,$); -#1973=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 13 13','Mineral Hollow Core Sheets',#1971,$,$); -#1974=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 13 15','Metal Hollow Core Sheets',#1971,$,$); -#1975=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 13 17','Plastic Hollow Core Sheets',#1971,$,$); -#1976=IFCCLASSIFICATIONREFERENCE($,'23-13 19 15','Gratings',#1950,$,$); -#1977=IFCCLASSIFICATIONREFERENCE($,'23-13 19 17','Blankets, Quilts',#1950,$,$); -#1978=IFCCLASSIFICATIONREFERENCE($,'23-13 21 00','Blocks and Bricks',#1847,$,$); -#1979=IFCCLASSIFICATIONREFERENCE($,'23-13 21 11','Concrete Masonry Units',#1978,$,$); -#1980=IFCCLASSIFICATIONREFERENCE($,'23-13 21 11 11','Concrete Blocks',#1979,$,$); -#1981=IFCCLASSIFICATIONREFERENCE($,'23-13 21 11 13','Exposed Aggregate Concrete Masonry Units',#1979,$,$); -#1982=IFCCLASSIFICATIONREFERENCE($,'23-13 21 11 15','Fluted Concrete Masonry Units',#1979,$,$); -#1983=IFCCLASSIFICATIONREFERENCE($,'23-13 21 11 17','Interlocking Concrete Masonry Units',#1979,$,$); -#1984=IFCCLASSIFICATIONREFERENCE($,'23-13 21 11 19','Molded Face Concrete Masonry Units',#1979,$,$); -#1985=IFCCLASSIFICATIONREFERENCE($,'23-13 21 11 21','Prefaced Concrete Masonry Units',#1979,$,$); -#1986=IFCCLASSIFICATIONREFERENCE($,'23-13 21 11 23','Preinsulated Concrete Masonry Units',#1979,$,$); -#1987=IFCCLASSIFICATIONREFERENCE($,'23-13 21 11 25','Sound Absorbing Concrete Masonry Units',#1979,$,$); -#1988=IFCCLASSIFICATIONREFERENCE($,'23-13 21 11 27','Split Face Concrete Masonry Units',#1979,$,$); -#1989=IFCCLASSIFICATIONREFERENCE($,'23-13 21 13','Calcium Silicate Masonry Units',#1978,$,$); -#1990=IFCCLASSIFICATIONREFERENCE($,'23-13 21 15','Glass Masonry Units',#1978,$,$); -#1991=IFCCLASSIFICATIONREFERENCE($,'23-13 21 17','Adobe Masonry Units',#1978,$,$); -#1992=IFCCLASSIFICATIONREFERENCE($,'23-13 21 19','Clay Masonry Units',#1978,$,$); -#1993=IFCCLASSIFICATIONREFERENCE($,'23-13 21 19 11','Common Bricks',#1992,$,$); -#1994=IFCCLASSIFICATIONREFERENCE($,'23-13 21 19 13','Face Bricks',#1992,$,$); -#1995=IFCCLASSIFICATIONREFERENCE($,'23-13 21 19 15','Fire Bricks',#1992,$,$); -#1996=IFCCLASSIFICATIONREFERENCE($,'23-13 21 19 17','Glazed Bricks',#1992,$,$); -#1997=IFCCLASSIFICATIONREFERENCE($,'23-13 21 19 19','Ceramic Glazed Clay Masonry Units',#1992,$,$); -#1998=IFCCLASSIFICATIONREFERENCE($,'23-13 21 19 21','Clay Tile',#1992,$,$); -#1999=IFCCLASSIFICATIONREFERENCE($,'23-13 21 19 23','Structural Clay Tiles',#1992,$,$); -#2000=IFCCLASSIFICATIONREFERENCE($,'23-13 21 19 25','Clay Flue Linings',#1992,$,$); -#2001=IFCCLASSIFICATIONREFERENCE($,'23-13 21 19 27','Terra Cotta Units',#1992,$,$); -#2002=IFCCLASSIFICATIONREFERENCE($,'23-13 21 21','Masonry Anchorage and Reinforcement',#1978,$,$); -#2003=IFCCLASSIFICATIONREFERENCE($,'23-13 21 21 11','Masonry Reinforcing',#2002,$,$); -#2004=IFCCLASSIFICATIONREFERENCE($,'23-13 21 21 11 11','Continuous Joint Reinforcing',#2003,$,$); -#2005=IFCCLASSIFICATIONREFERENCE($,'23-13 21 21 11 13','Reinforcing Bars',#2003,$,$); -#2006=IFCCLASSIFICATIONREFERENCE($,'23-13 21 21 13','Masonry Ties',#2002,$,$); -#2007=IFCCLASSIFICATIONREFERENCE($,'23-13 21 21 13 11','Flexible Masonry Ties',#2006,$,$); -#2008=IFCCLASSIFICATIONREFERENCE($,'23-13 21 21 13 13','Masonry Veneer Ties',#2006,$,$); -#2009=IFCCLASSIFICATIONREFERENCE($,'23-13 21 21 13 15','Rigid Masonry Ties',#2006,$,$); -#2010=IFCCLASSIFICATIONREFERENCE($,'23-13 21 21 15','Masonry Anchors',#2002,$,$); -#2011=IFCCLASSIFICATIONREFERENCE($,'23-13 21 21 15 11','Masonry Veneer Anchors',#2010,$,$); -#2012=IFCCLASSIFICATIONREFERENCE($,'23-13 21 21 15 13','Stone Masonry Anchors',#2010,$,$); -#2013=IFCCLASSIFICATIONREFERENCE($,'23-13 21 23','Special Profiles for Masonry',#1978,$,$); -#2014=IFCCLASSIFICATIONREFERENCE($,'23-13 21 23 11','Special Masonry Shapes',#2013,$,$); -#2015=IFCCLASSIFICATIONREFERENCE($,'23-13 21 23 13','Masonry Sills and Thresholds',#2013,$,$); -#2016=IFCCLASSIFICATIONREFERENCE($,'23-13 21 23 15','Masonry Moldings',#2013,$,$); -#2017=IFCCLASSIFICATIONREFERENCE($,'23-13 21 23 17','Masonry Copings',#2013,$,$); -#2018=IFCCLASSIFICATIONREFERENCE($,'23-13 21 23 19','Masonry Quoins',#2013,$,$); -#2019=IFCCLASSIFICATIONREFERENCE($,'23-13 21 23 21','Masonry Cornices',#2013,$,$); -#2020=IFCCLASSIFICATIONREFERENCE($,'23-13 21 25','Structural Support for Masonry',#1978,$,$); -#2021=IFCCLASSIFICATIONREFERENCE($,'23-13 21 25 11','Lintels',#2020,$,$); -#2022=IFCCLASSIFICATIONREFERENCE($,'23-13 21 25 11 11','Lintel Former Units',#2021,$,$); -#2023=IFCCLASSIFICATIONREFERENCE($,'23-13 21 25 13','Wall Connectors and Starters',#2020,$,$); -#2024=IFCCLASSIFICATIONREFERENCE($,'23-13 21 25 15','Supports for Masonry',#2020,$,$); -#2025=IFCCLASSIFICATIONREFERENCE($,'23-13 21 25 15 11','Masonry Angles',#2024,$,$); -#2026=IFCCLASSIFICATIONREFERENCE($,'23-13 21 25 15 11 11','Masonry Shelf Angles',#2025,$,$); -#2027=IFCCLASSIFICATIONREFERENCE($,'23-13 21 25 15 13','Gussets',#2024,$,$); -#2028=IFCCLASSIFICATIONREFERENCE($,'23-13 21 27','Ancillary Products for Masonry',#1978,$,$); -#2029=IFCCLASSIFICATIONREFERENCE($,'23-13 21 27 11','Embedded Flashing',#2028,$,$); -#2030=IFCCLASSIFICATIONREFERENCE($,'23-13 21 27 13','Cavity Closers',#2028,$,$); -#2031=IFCCLASSIFICATIONREFERENCE($,'23-13 21 27 15','Cavity Weep and Ventilation Units',#2028,$,$); -#2032=IFCCLASSIFICATIONREFERENCE($,'23-13 21 27 15 11','Cavity Weeps',#2031,$,$); -#2033=IFCCLASSIFICATIONREFERENCE($,'23-13 21 27 15 13','Cavity Vents',#2031,$,$); -#2034=IFCCLASSIFICATIONREFERENCE($,'23-13 21 27 15 15','Cavity Drainage Material',#2031,$,$); -#2035=IFCCLASSIFICATIONREFERENCE($,'23-13 21 27 17','Masonry Joint Materials',#2028,$,$); -#2036=IFCCLASSIFICATIONREFERENCE($,'23-13 21 27 17 11','Masonry Control Joints',#2035,$,$); -#2037=IFCCLASSIFICATIONREFERENCE($,'23-13 21 27 17 13','Masonry Expansion Joints',#2035,$,$); -#2038=IFCCLASSIFICATIONREFERENCE($,'23-13 21 27 19','Airbricks',#2028,$,$); -#2039=IFCCLASSIFICATIONREFERENCE($,'23-13 23 00','Mechanical Fasteners, Adhesives, and Sealants',#1847,$,$); -#2040=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11','Mechanical Fasteners',#2039,$,$); -#2041=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 11','Cast In Anchorages',#2040,$,$); -#2042=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 11 11','Rail Anchors',#2041,$,$); -#2043=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 11 13','Screw Cases',#2041,$,$); -#2044=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 11 15','Anchor Blocks',#2041,$,$); -#2045=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 11 17','Cast In Anchorages Inserts',#2041,$,$); -#2046=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 11 17 11','Cast In Anchorages Inserts Adjustable Wedges',#2045,$,$); -#2047=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 11 17 13','Cast In Anchorages Inserts Adjustable Boxes',#2045,$,$); -#2048=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 11 17 15','Threaded Cast In Anchorages Inserts',#2045,$,$); -#2049=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 11 19','Dovetail Slots',#2041,$,$); -#2050=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 13','Multi Purpose Mechanical Fasteners',#2040,$,$); -#2051=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 13 11','Plugs',#2050,$,$); -#2052=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 13 13','Staples',#2050,$,$); -#2053=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 13 15','Nails',#2050,$,$); -#2054=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 13 17','Rivets',#2050,$,$); -#2055=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 13 19','Screws',#2050,$,$); -#2056=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 13 21','Bolts and Nuts',#2050,$,$); -#2057=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 13 23','Threaded Rods and Nuts',#2050,$,$); -#2058=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 13 25','Bandings',#2050,$,$); -#2059=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 15','Structural Mechanical Fasteners in Hardened Concrete and Masonry',#2040,$,$); -#2060=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 15 11','Expansion Anchors',#2059,$,$); -#2061=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 15 13','Undercut Anchors',#2059,$,$); -#2062=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 15 15','Bonded Anchors',#2059,$,$); -#2063=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 17','Mechanical Fasteners for Metal Structures',#2040,$,$); -#2064=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 19','Mechanical Fasteners for Wood Structures',#2040,$,$); -#2065=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 19 11','Nail Plates',#2064,$,$); -#2066=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 19 13','Wood Connectors',#2064,$,$); -#2067=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 19 15','Framing Anchors',#2064,$,$); -#2068=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 21','Mechanical Fasteners for Glass Structures',#2040,$,$); -#2069=IFCCLASSIFICATIONREFERENCE($,'23-13 23 13','Welded Joint Products',#2039,$,$); -#2070=IFCCLASSIFICATIONREFERENCE($,'23-13 23 13 11','Soldering Products',#2069,$,$); -#2071=IFCCLASSIFICATIONREFERENCE($,'23-13 23 13 13','Brazing Products',#2069,$,$); -#2072=IFCCLASSIFICATIONREFERENCE($,'23-13 23 13 15','Welding Products',#2069,$,$); -#2073=IFCCLASSIFICATIONREFERENCE($,'23-13 23 15','Adhesives',#2039,$,$); -#2074=IFCCLASSIFICATIONREFERENCE($,'23-13 23 15 11','Natural Adhesives and Glues',#2073,$,$); -#2075=IFCCLASSIFICATIONREFERENCE($,'23-13 23 15 13','Synthetic Adhesives',#2073,$,$); -#2076=IFCCLASSIFICATIONREFERENCE($,'23-13 23 15 15','Sound Proofing Adhesive',#2073,$,$); -#2077=IFCCLASSIFICATIONREFERENCE($,'23-13 23 17','General Purpose Tape',#2039,$,$); -#2078=IFCCLASSIFICATIONREFERENCE($,'23-13 23 19','Joint Fillers, Sealants, and Mastics',#2039,$,$); -#2079=IFCCLASSIFICATIONREFERENCE($,'23-13 23 19 11','Joint Fillers',#2078,$,$); -#2080=IFCCLASSIFICATIONREFERENCE($,'23-13 23 19 11 11','Backer Rods',#2079,$,$); -#2081=IFCCLASSIFICATIONREFERENCE($,'23-13 23 19 13','Putties',#2078,$,$); -#2082=IFCCLASSIFICATIONREFERENCE($,'23-13 23 19 15','Construction Sealants',#2078,$,$); -#2083=IFCCLASSIFICATIONREFERENCE($,'23-13 23 19 15 11','Elastomeric Construction Sealants',#2082,$,$); -#2084=IFCCLASSIFICATIONREFERENCE($,'23-13 23 19 15 13','Rigid Construction Sealants',#2082,$,$); -#2085=IFCCLASSIFICATIONREFERENCE($,'23-13 23 19 15 15','Sanitary Construction Sealants',#2082,$,$); -#2086=IFCCLASSIFICATIONREFERENCE($,'23-13 23 19 15 17','Chemical Resistant Construction Sealants',#2082,$,$); -#2087=IFCCLASSIFICATIONREFERENCE($,'23-13 23 19 15 19','Water Immersed Construction Sealants',#2082,$,$); -#2088=IFCCLASSIFICATIONREFERENCE($,'23-13 23 19 17','Preformed Joint Seals',#2078,$,$); -#2089=IFCCLASSIFICATIONREFERENCE($,'23-13 23 19 17 11','Compression Seals',#2088,$,$); -#2090=IFCCLASSIFICATIONREFERENCE($,'23-13 23 19 17 13','Joint Gaskets',#2088,$,$); -#2091=IFCCLASSIFICATIONREFERENCE($,'23-13 23 21','Ropes, Wires, and Cables',#2039,$,$); -#2092=IFCCLASSIFICATIONREFERENCE($,'23-13 23 21 11','Ropes',#2091,$,$); -#2093=IFCCLASSIFICATIONREFERENCE($,'23-13 23 21 13','Wires',#2091,$,$); -#2094=IFCCLASSIFICATIONREFERENCE($,'23-13 23 21 15','Cables',#2091,$,$); -#2095=IFCCLASSIFICATIONREFERENCE($,'23-13 25 00','Thermal and Moisture Protective Products',#1847,$,$); -#2096=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11','Fireproofing',#2095,$,$); -#2097=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11 11','Board Fireproofing',#2096,$,$); -#2098=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11 11 11','Calcium Silicate Board Fireproofing',#2097,$,$); -#2099=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11 11 13','Slag Fiberboard Fireproofing',#2097,$,$); -#2100=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11 13','Blanket Fireproofing',#2096,$,$); -#2101=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11 13 11','Blanket Fireproofing Smoke Containment Barriers',#2100,$,$); -#2102=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11 15','Fireproofing Coatings',#2096,$,$); -#2103=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11 15 11','Cement Aggregate Fireproofing',#2102,$,$); -#2104=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11 15 13','Cementitious Fireproofing',#2102,$,$); -#2105=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11 15 15','Foamed Magnesium Oxychloride Fireproofing',#2102,$,$); -#2106=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11 15 17','Intumescent Mastic Fireproofing',#2102,$,$); -#2107=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11 15 19','Magnesium Cement Fireproofing',#2102,$,$); -#2108=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11 15 21','Mineral Fiber Cementitious Fireproofing',#2102,$,$); -#2109=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11 15 23','Miner Fiber Fireproofing',#2102,$,$); -#2110=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13','Firestopping',#2095,$,$); -#2111=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13 11','Penetrations Firestopping',#2110,$,$); -#2112=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13 11 11','Annular Space Protection Firestopping',#2111,$,$); -#2113=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13 11 13','Fire Resistant Joint Sealants',#2111,$,$); -#2114=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13 11 15','Firestopping Foams',#2111,$,$); -#2115=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13 11 15 11','Intumescent Firestopping Foams',#2114,$,$); -#2116=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13 11 15 13','Silicone Firestopping Foams',#2114,$,$); -#2117=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13 11 17','Firestopping Mortars',#2111,$,$); -#2118=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13 11 19','Firestopping Pillows',#2111,$,$); -#2119=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13 11 21','Firestopping Thermal Barriers for Plastics',#2111,$,$); -#2120=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13 13','Fire Safing',#2110,$,$); -#2121=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13 13 11','Fire Safing Fibrous Blankets',#2120,$,$); -#2122=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13 13 13','Fire Safing Sealants',#2120,$,$); -#2123=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13 13 15','Fire Safing Clip Anchors',#2120,$,$); -#2124=IFCCLASSIFICATIONREFERENCE($,'23-13 25 15','Dampproofings',#2095,$,$); -#2125=IFCCLASSIFICATIONREFERENCE($,'23-13 25 15 11','Dampproofing Membranes',#2124,$,$); -#2126=IFCCLASSIFICATIONREFERENCE($,'23-13 25 15 13','Dampproofing Coatings',#2124,$,$); -#2127=IFCCLASSIFICATIONREFERENCE($,'23-13 25 15 13 11','Bituminous Dampproofing Coatings',#2126,$,$); -#2128=IFCCLASSIFICATIONREFERENCE($,'23-13 25 15 13 13','Cementitious Dampproofing Coatings',#2126,$,$); -#2129=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17','Waterproofing',#2095,$,$); -#2130=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 11','Built Up Bituminous Waterproofing',#2129,$,$); -#2131=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 13','Sheet Waterproofing',#2129,$,$); -#2132=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 13 11','Bituminous Sheet Waterproofing',#2131,$,$); -#2133=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 13 13','Elastomeric Sheet Waterproofing',#2131,$,$); -#2134=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 13 15','Modified Bituminous Sheet Waterproofing',#2131,$,$); -#2135=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 13 17','Thermoplastic Sheet Waterproofing',#2131,$,$); -#2136=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 15','Fluid Applied Waterproofing',#2129,$,$); -#2137=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 15 11','Hot Applied Rubberized Asphalt',#2136,$,$); -#2138=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 17','Sheet Metal Waterproofing',#2129,$,$); -#2139=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 19','Cementitious and Reactive Waterproofing',#2129,$,$); -#2140=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 19 11','Acrylic Modified Cement Waterproofing',#2139,$,$); -#2141=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 19 13','Crystalline Waterproofing',#2139,$,$); -#2142=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 19 15','Metal Oxide Waterproofing',#2139,$,$); -#2143=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 21','Bentonite Waterproofing',#2129,$,$); -#2144=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 21 11','Bentonite Panel Waterproofing',#2143,$,$); -#2145=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 21 13','Bentonite Sheet Waterproofing',#2143,$,$); -#2146=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 23','Waterproof Traffic Coatings',#2129,$,$); -#2147=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 23 11','Pedestrian Waterproof Traffic Coatings',#2146,$,$); -#2148=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 23 13','Vehicular Waterproof Traffic Coatings',#2146,$,$); -#2149=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19','Thermal Insulation',#2095,$,$); -#2150=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 11','Slab and Board Thermal Insulation',#2149,$,$); -#2151=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 11 11','Polystyrene Slab and Board Thermal Insulation',#2150,$,$); -#2152=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 11 11 11','Expanded Polystyrene Slab and Board Thermal Insulation',#2151,$,$); -#2153=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 11 11 13','Extruded Polystyrene Slab and Board Thermal Insulation',#2151,$,$); -#2154=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 11 13','Urethane Slab and Board Thermal Insulation',#2150,$,$); -#2155=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 11 15','Perlite Slab and Board Thermal Insulation',#2150,$,$); -#2156=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 11 17','Fiberglass Slab and Board Thermal Insulation',#2150,$,$); -#2157=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 13','Blanket Thermal Insulation',#2149,$,$); -#2158=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 13 11','Fiberglass Blanket Thermal Insulation',#2157,$,$); -#2159=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 13 13','Rock Wool Blanket Thermal Insulation',#2157,$,$); -#2160=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 15','Thermal Insulation Coatings',#2149,$,$); -#2161=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 15 11','Sprayed Thermal Insulation Coatings',#2160,$,$); -#2162=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 15 11 11','Sprayed Cellulose Thermal Insulation Coatings',#2161,$,$); -#2163=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 17','Loose Fill Thermal Insulation',#2149,$,$); -#2164=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 17 11','Granular Fill Thermal Insulation',#2163,$,$); -#2165=IFCCLASSIFICATIONREFERENCE($,'23-13 25 21','Sound Isolation Insulation',#2095,$,$); -#2166=IFCCLASSIFICATIONREFERENCE($,'23-13 25 21 11','Slab and Board Sound Isolation Insulation',#2165,$,$); -#2167=IFCCLASSIFICATIONREFERENCE($,'23-13 25 21 13','Fiberglass Slab and Board Sound Isolation Insulation',#2165,$,$); -#2168=IFCCLASSIFICATIONREFERENCE($,'23-13 25 21 15','Blanket Sound Isolation Insulation',#2165,$,$); -#2169=IFCCLASSIFICATIONREFERENCE($,'23-13 25 21 15 11','Fiberglass Blanket Sound Isolation Insulation',#2168,$,$); -#2170=IFCCLASSIFICATIONREFERENCE($,'23-13 25 21 15 13','Rock Wool Blanket Sound Isolation Insulation',#2168,$,$); -#2171=IFCCLASSIFICATIONREFERENCE($,'23-13 25 21 17','Sound Isolation Coatings',#2165,$,$); -#2172=IFCCLASSIFICATIONREFERENCE($,'23-13 25 21 19','Sound Isolation Loose Fills',#2165,$,$); -#2173=IFCCLASSIFICATIONREFERENCE($,'23-13 25 21 19 11','Granular Sound Isolation Loose Fills',#2172,$,$); -#2174=IFCCLASSIFICATIONREFERENCE($,'23-13 25 23','Damage Prevention Products',#2095,$,$); -#2175=IFCCLASSIFICATIONREFERENCE($,'23-13 25 23 11','Products for Prevention of Biological Damage',#2174,$,$); -#2176=IFCCLASSIFICATIONREFERENCE($,'23-13 25 23 11 11','Coatings for Prevention of Biological Damage',#2175,$,$); -#2177=IFCCLASSIFICATIONREFERENCE($,'23-13 25 23 13','Products for Prevention of Chemical Damage',#2174,$,$); -#2178=IFCCLASSIFICATIONREFERENCE($,'23-13 25 23 13 11','Tiles and Slabs for Prevention of Chemical Damage',#2177,$,$); -#2179=IFCCLASSIFICATIONREFERENCE($,'23-13 25 23 13 13','Sheets for Prevention of Chemical Damage',#2177,$,$); -#2180=IFCCLASSIFICATIONREFERENCE($,'23-13 25 23 13 15','Coatings for Prevention of Chemical Damage',#2177,$,$); -#2181=IFCCLASSIFICATIONREFERENCE($,'23-13 25 23 15','Products for Prevention of Abrasive Wear',#2174,$,$); -#2182=IFCCLASSIFICATIONREFERENCE($,'23-13 25 25','Air Barriers',#2095,$,$); -#2183=IFCCLASSIFICATIONREFERENCE($,'23-13 25 27','Vapor Barriers',#2095,$,$); -#2184=IFCCLASSIFICATIONREFERENCE($,'23-13 27 00','Maintenance Products and Chemicals for Construction',#1847,$,$); -#2185=IFCCLASSIFICATIONREFERENCE($,'23-13 27 11','Cleaning and Maintenance Products',#2184,$,$); -#2186=IFCCLASSIFICATIONREFERENCE($,'23-13 27 11 11','Cleaning Products',#2185,$,$); -#2187=IFCCLASSIFICATIONREFERENCE($,'23-13 27 11 13','Maintenance Products',#2185,$,$); -#2188=IFCCLASSIFICATIONREFERENCE($,'23-13 27 11 15','Combined Cleaning and Protection Products',#2185,$,$); -#2189=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13','Repair Products',#2184,$,$); -#2190=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 11','Repair Mortars',#2189,$,$); -#2191=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 13','Concrete Restoration and Cleaning Products',#2189,$,$); -#2192=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 13 11','Concrete Cleaning Products',#2191,$,$); -#2193=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 13 13','Concrete Resurfacing Products',#2191,$,$); -#2194=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 13 15','Concrete Rehabilitation Products',#2191,$,$); -#2195=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 15','Masonry Restoration and Cleaning Products',#2189,$,$); -#2196=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 15 11','Unit Masonry Restoration Products',#2195,$,$); -#2197=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 15 13','Stone Restoration products',#2195,$,$); -#2198=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 15 15','Unit Masonry Cleaning Products',#2195,$,$); -#2199=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 15 17','Stone Cleaning products',#2195,$,$); -#2200=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 17','Metal Restoration and Cleaning Products',#2189,$,$); -#2201=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 19','Wood and Plastic Restoration and Cleaning Products',#2189,$,$); -#2202=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 19 11','Wood Restoration and Cleaning Products',#2201,$,$); -#2203=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 19 13','Plastic Restoration and Cleaning Products',#2201,$,$); -#2204=IFCCLASSIFICATIONREFERENCE($,'23-13 27 15','Chemicals for Construction',#2184,$,$); -#2205=IFCCLASSIFICATIONREFERENCE($,'23-13 27 15 11','Solvents',#2204,$,$); -#2206=IFCCLASSIFICATIONREFERENCE($,'23-13 27 15 13','Acids',#2204,$,$); -#2207=IFCCLASSIFICATIONREFERENCE($,'23-13 27 15 15','Alkalis',#2204,$,$); -#2208=IFCCLASSIFICATIONREFERENCE($,'23-13 27 15 17','Salts',#2204,$,$); -#2209=IFCCLASSIFICATIONREFERENCE($,'23-13 29 00','Foundations',#1847,$,$); -#2210=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11','Foundation Piles',#2209,$,$); -#2211=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 11','Foundation Pile Components',#2210,$,$); -#2212=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 11 11','Pile Casings (Linings)',#2211,$,$); -#2213=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 11 13','Cores and Mandrels',#2211,$,$); -#2214=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 11 15','Pile Extension Pieces',#2211,$,$); -#2215=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 11 17','Pile Shoes',#2211,$,$); -#2216=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 11 19','Pile Splices',#2211,$,$); -#2217=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 11 21','Pile Caps',#2211,$,$); -#2218=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 13','Driven Piles',#2210,$,$); -#2219=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 13 11','Composite Driven Piles',#2218,$,$); -#2220=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 13 13','Concrete Filled Steel Driven Piles',#2218,$,$); -#2221=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 13 15','Precast Concrete Driven Piles',#2218,$,$); -#2222=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 13 17','Rolled Steel Section Driven Piles',#2218,$,$); -#2223=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 13 19','Unfilled Tubular Steel Driven Piles',#2218,$,$); -#2224=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 13 21','Wood Driven Piles',#2218,$,$); -#2225=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 13 23','Sheet Driven Piles',#2218,$,$); -#2226=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 15','Screw Piles',#2210,$,$); -#2227=IFCCLASSIFICATIONREFERENCE($,'23-13 29 13','Caissons, Foundation Casings',#2209,$,$); -#2228=IFCCLASSIFICATIONREFERENCE($,'23-13 29 13 11','Well Foundation Casings',#2227,$,$); -#2229=IFCCLASSIFICATIONREFERENCE($,'23-13 29 13 13','Caissons',#2227,$,$); -#2230=IFCCLASSIFICATIONREFERENCE($,'23-13 29 15','Shallow Foundations',#2209,$,$); -#2231=IFCCLASSIFICATIONREFERENCE($,'23-13 29 15 11','Column Bases',#2230,$,$); -#2232=IFCCLASSIFICATIONREFERENCE($,'23-13 29 15 13','Grade Beams',#2230,$,$); -#2233=IFCCLASSIFICATIONREFERENCE($,'23-13 29 15 15','Strip Foundation Blocks',#2230,$,$); -#2234=IFCCLASSIFICATIONREFERENCE($,'23-13 29 17','Special Foundations',#2209,$,$); -#2235=IFCCLASSIFICATIONREFERENCE($,'23-13 29 17 11','Controlled Modulus Columns',#2234,$,$); -#2236=IFCCLASSIFICATIONREFERENCE($,'23-13 29 17 13','Other Special Foundations',#2234,$,$); -#2237=IFCCLASSIFICATIONREFERENCE($,'23-13 31 00','Structural Concrete Products',#1847,$,$); -#2238=IFCCLASSIFICATIONREFERENCE($,'23-13 31 11','Structural Concrete',#2237,$,$); -#2239=IFCCLASSIFICATIONREFERENCE($,'23-13 31 13','Ready Mixed Concrete',#2237,$,$); -#2240=IFCCLASSIFICATIONREFERENCE($,'23-13 31 15','Precast Structural Concrete',#2237,$,$); -#2241=IFCCLASSIFICATIONREFERENCE($,'23-13 31 17','Concrete Formwork',#2237,$,$); -#2242=IFCCLASSIFICATIONREFERENCE($,'23-13 31 17 11','Steel Forms',#2241,$,$); -#2243=IFCCLASSIFICATIONREFERENCE($,'23-13 31 17 13','Prefabricated Stair Forms',#2241,$,$); -#2244=IFCCLASSIFICATIONREFERENCE($,'23-13 31 17 15','Concrete Form Liners',#2241,$,$); -#2245=IFCCLASSIFICATIONREFERENCE($,'23-13 31 17 17','Insulated Concrete Forms',#2241,$,$); -#2246=IFCCLASSIFICATIONREFERENCE($,'23-13 31 19','Non Formwork',#2237,$,$); -#2247=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21','Reinforcement and Prestressing Components',#2237,$,$); -#2248=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 11','Reinforcement Components',#2247,$,$); -#2249=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 11 11','Reinforcing Steel',#2248,$,$); -#2250=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 11 13','Reinforcement Steel Mesh',#2248,$,$); -#2251=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 11 13 11','Welded Wire Fabric Reinforcing',#2250,$,$); -#2252=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 11 15','Fibrous Reinforcing',#2248,$,$); -#2253=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 11 15 11','Steel Fibrous Reinforcing',#2252,$,$); -#2254=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 11 15 13','Synthetic Fibrous Reinforcing',#2252,$,$); -#2255=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 11 17','Reinforcement Couplers',#2248,$,$); -#2256=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 11 19','Reinforcement Spacers',#2248,$,$); -#2257=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 11 21','Reinforcement Accessories',#2248,$,$); -#2258=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 13','Prestressing Components',#2247,$,$); -#2259=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 13 11','Stressing Tendons',#2258,$,$); -#2260=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 13 11 11','Steel Stressing Tendons',#2259,$,$); -#2261=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 13 11 11 11','Steel Strand Stressing Tendons',#2260,$,$); -#2262=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 13 11 11 13','Steel Wire Stressing Tendons',#2260,$,$); -#2263=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 13 11 11 15','Steel Bar Stressing Tendons',#2260,$,$); -#2264=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 13 11 13','Glass Fibers',#2259,$,$); -#2265=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 13 13','Steel Bars',#2258,$,$); -#2266=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 13 15','Glass Fiber Tendons',#2258,$,$); -#2267=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 13 17','Prestressing Couplers',#2258,$,$); -#2268=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 13 19','Tendon Sheathing',#2258,$,$); -#2269=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 13 19 11','Tendon Sheathing Ducts',#2268,$,$); -#2270=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 13 21','Prestressing Anchorages',#2258,$,$); -#2271=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 15','Post Tensioning Products',#2247,$,$); -#2272=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 17','Complete Reinforcement Cages',#2247,$,$); -#2273=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 19','Cast In Jointing',#2247,$,$); -#2274=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 19 11','Expansion and Contraction Joints',#2273,$,$); -#2275=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 19 13','Waterstops',#2273,$,$); -#2276=IFCCLASSIFICATIONREFERENCE($,'23-13 31 23','Concrete Finishing Products',#2237,$,$); -#2277=IFCCLASSIFICATIONREFERENCE($,'23-13 31 23 11','Stamped Concrete Finishing Products',#2276,$,$); -#2278=IFCCLASSIFICATIONREFERENCE($,'23-13 31 23 13','Colored Concrete Finishing Products',#2276,$,$); -#2279=IFCCLASSIFICATIONREFERENCE($,'23-13 33 00','Envelope Enclosure Products',#1847,$,$); -#2280=IFCCLASSIFICATIONREFERENCE($,'23-13 33 11','Sliding Glass Wall Systems',#2279,$,$); -#2281=IFCCLASSIFICATIONREFERENCE($,'23-13 33 13','Folding Glass Wall Systems',#2279,$,$); -#2282=IFCCLASSIFICATIONREFERENCE($,'23-13 33 15','Wall Exteriors',#2279,$,$); -#2283=IFCCLASSIFICATIONREFERENCE($,'23-13 33 15 11','Blast Resistant Wall Exteriors',#2282,$,$); -#2284=IFCCLASSIFICATIONREFERENCE($,'23-13 33 17','Infill Facades',#2279,$,$); -#2285=IFCCLASSIFICATIONREFERENCE($,'23-13 33 17 11','Exterior Wall Assemblies',#2284,$,$); -#2286=IFCCLASSIFICATIONREFERENCE($,'23-13 33 19','Precast Concrete Facade',#2279,$,$); -#2287=IFCCLASSIFICATIONREFERENCE($,'23-13 33 19 11','Cladding and Curtainwall Panels',#2286,$,$); -#2288=IFCCLASSIFICATIONREFERENCE($,'23-13 33 19 11 11','Opening Infill Units',#2287,$,$); -#2289=IFCCLASSIFICATIONREFERENCE($,'23-13 33 19 11 13','Imbedded Material Finish Mix, Tiles, Brick',#2287,$,$); -#2290=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21','Entrances',#2279,$,$); -#2291=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 11','Aluminum-Framed Entrances',#2290,$,$); -#2292=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 11 11','Automatic Aluminum-Framed Entrances',#2291,$,$); -#2293=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 11 13','Revolving Door Aluminum-Framed Entrances',#2291,$,$); -#2294=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 11 15','Balanced Door Aluminum-Framed Entrances',#2291,$,$); -#2295=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 11 17','Pressure-Resistant Aluminum-Framed Entrances',#2291,$,$); -#2296=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 11 19','Intensive Care Unit/Critical Care Unit Aluminum-Framed Entrances',#2291,$,$); -#2297=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 13','Bronze-Framed Entrances',#2290,$,$); -#2298=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 13 11','Automatic Bronze-Framed Entrances',#2297,$,$); -#2299=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 13 13','Revolving Door Bronze-Framed Entrances',#2297,$,$); -#2300=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 13 15','Balanced Door Bronze-Framed Entrances',#2297,$,$); -#2301=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 13 17','Pressure-Resistant Bronze-Framed Entrances',#2297,$,$); -#2302=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 13 19','Intensive Care Unit/Critical Care Unit Bronze-Framed Entrances',#2297,$,$); -#2303=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 15','Stainless-Steel-Framed Entrances',#2290,$,$); -#2304=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 15 11','Automatic Stainless-Steel-Framed Entrances',#2303,$,$); -#2305=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 15 13','Revolving Door Stainless-Steel-Framed Entrances',#2303,$,$); -#2306=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 15 15','Balanced Door Stainless-Steel-Framed Entrances',#2303,$,$); -#2307=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 15 17','Pressure-Resistant Stainless-Steel-Framed Entrances',#2303,$,$); -#2308=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 15 19','Intensive Care Unit/Critical Care Unit Stainless-Steel-Framed Entrances',#2303,$,$); -#2309=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 17','Steel-Framed Entrances',#2290,$,$); -#2310=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 17 11','Automatic Steel-Framed Entrances',#2309,$,$); -#2311=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 17 13','Revolving Door Steel-Framed Entrances',#2309,$,$); -#2312=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 17 15','Balanced Door Steel-Framed Entrances',#2309,$,$); -#2313=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 17 17','Pressure-Resistant Steel-Framed Entrances',#2309,$,$); -#2314=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 17 19','Intensive Care Unit/Critical Care Unit Steel-Framed Entrances',#2309,$,$); -#2315=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 19','All-Glass Entrances',#2290,$,$); -#2316=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 19 11','Automatic All-Glass Entrances',#2315,$,$); -#2317=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 19 13','Revolving Door All-Glass Entrances',#2315,$,$); -#2318=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 19 15','Balanced Door All-Glass Entrances',#2315,$,$); -#2319=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 19 17','Pressure-Resistant All-Glass Entrances',#2315,$,$); -#2320=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 19 19','Intensive Care Unit/Critical Care Unit All-Glass Entrances',#2315,$,$); -#2321=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23','Storefronts',#2279,$,$); -#2322=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 11','Aluminum-Framed Storefronts',#2321,$,$); -#2323=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 11 11','Automatic Aluminum-Framed Storefronts',#2322,$,$); -#2324=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 11 13','Revolving Door Aluminum-Framed Storefronts',#2322,$,$); -#2325=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 11 15','Balanced Door Aluminum-Framed Storefronts',#2322,$,$); -#2326=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 11 17','Pressure-Resistant Aluminum-Framed Storefronts',#2322,$,$); -#2327=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 11 19','Intensive Care Unit/Critical Care Unit Aluminum-Framed Storefronts',#2322,$,$); -#2328=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 13','Bronze-Framed Storefronts',#2321,$,$); -#2329=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 13 11','Automatic Bronze-Framed Storefronts',#2328,$,$); -#2330=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 13 13','Revolving Door Bronze-Framed Storefronts',#2328,$,$); -#2331=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 13 15','Balanced Door Bronze-Framed Storefronts',#2328,$,$); -#2332=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 13 17','Pressure-Resistant Bronze-Framed Storefronts',#2328,$,$); -#2333=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 13 19','Intensive Care Unit/Critical Care Unit Bronze-Framed Storefronts',#2328,$,$); -#2334=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 15','Stainless-Steel-Framed Storefronts',#2321,$,$); -#2335=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 15 11','Automatic Stainless-Steel-Framed Storefronts',#2334,$,$); -#2336=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 15 13','Revolving Door Stainless-Steel-Framed Storefronts',#2334,$,$); -#2337=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 15 15','Balanced Door Stainless-Steel-Framed Storefronts',#2334,$,$); -#2338=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 15 17','Pressure-Resistant Stainless-Steel-Framed Storefronts',#2334,$,$); -#2339=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 15 19','Intensive Care Unit/Critical Care Unit Stainless-Steel-Framed Storefronts',#2334,$,$); -#2340=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 17','Steel-Framed Storefronts',#2321,$,$); -#2341=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 17 11','Automatic Steel-Framed Storefronts',#2340,$,$); -#2342=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 17 13','Revolving Door Steel-Framed Storefronts',#2340,$,$); -#2343=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 17 15','Balanced Door Steel-Framed Storefronts',#2340,$,$); -#2344=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 17 17','Pressure-Resistant Steel-Framed Storefronts',#2340,$,$); -#2345=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 17 19','Intensive Care Unit/Critical Care Unit Steel-Framed Storefronts',#2340,$,$); -#2346=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 19','All-Glass Storefronts',#2321,$,$); -#2347=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 19 11','Automatic All-Glass Storefronts',#2346,$,$); -#2348=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 19 13','Revolving Door All-Glass Storefronts',#2346,$,$); -#2349=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 19 15','Balanced Door All-Glass Storefronts',#2346,$,$); -#2350=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 19 17','Pressure-Resistant All-Glass Storefronts',#2346,$,$); -#2351=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 19 19','Intensive Care Unit/Critical Care Unit All-Glass Storefronts',#2346,$,$); -#2352=IFCCLASSIFICATIONREFERENCE($,'23-13 33 25','Precast Modules',#2279,$,$); -#2353=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27','Glazed Facade and Roof Structures',#2279,$,$); -#2354=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 11','Curtain Walls',#2353,$,$); -#2355=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 11 11','Curtain Wall Components',#2354,$,$); -#2356=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 11 11 11','Curtain Wall Frames',#2355,$,$); -#2357=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 11 11 13','Curtain Wall Sections',#2355,$,$); -#2358=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 11 11 15','Curtain Wall Infill Panels',#2355,$,$); -#2359=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 11 13','Metal Framed Curtain Wall',#2354,$,$); -#2360=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 11 15','Translucent Curtain Wall Assemblies',#2354,$,$); -#2361=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 13','Structural Glazing',#2353,$,$); -#2362=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 13 11','Structural Glass Curtain Walls',#2361,$,$); -#2363=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 15','Suspended Glazing',#2353,$,$); -#2364=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 17','Patent Glazing',#2353,$,$); -#2365=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 19','Glazed Roof Structures',#2353,$,$); -#2366=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 19 11','Sections for Glazed Roofs',#2365,$,$); -#2367=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 19 13','Sloped Glazing Assemblies',#2365,$,$); -#2368=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 19 15','Translucent Roof Assemblies',#2365,$,$); -#2369=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 19 17','Translucent Wall Assemblies',#2365,$,$); -#2370=IFCCLASSIFICATIONREFERENCE($,'23-13 35 00','Framing Products',#1847,$,$); -#2371=IFCCLASSIFICATIONREFERENCE($,'23-13 35 11','Structural Frames',#2370,$,$); -#2372=IFCCLASSIFICATIONREFERENCE($,'23-13 35 11 11','Beam Column Frames',#2371,$,$); -#2373=IFCCLASSIFICATIONREFERENCE($,'23-13 35 11 13','Column Slab Frames',#2371,$,$); -#2374=IFCCLASSIFICATIONREFERENCE($,'23-13 35 11 13 11','Columns',#2373,$,$); -#2375=IFCCLASSIFICATIONREFERENCE($,'23-13 35 11 13 13','Beams',#2373,$,$); -#2376=IFCCLASSIFICATIONREFERENCE($,'23-13 35 11 15','Portal Frames',#2371,$,$); -#2377=IFCCLASSIFICATIONREFERENCE($,'23-13 35 11 17','Structural Racking',#2371,$,$); -#2378=IFCCLASSIFICATIONREFERENCE($,'23-13 35 11 19','Structural Bearings',#2371,$,$); -#2379=IFCCLASSIFICATIONREFERENCE($,'23-13 35 11 19 11','Structural Roller Bearings',#2378,$,$); -#2380=IFCCLASSIFICATIONREFERENCE($,'23-13 35 11 19 13','Structural Slide Bearings',#2378,$,$); -#2381=IFCCLASSIFICATIONREFERENCE($,'23-13 35 11 19 15','Structural Rocker Bearings',#2378,$,$); -#2382=IFCCLASSIFICATIONREFERENCE($,'23-13 35 11 19 17','Structural Fixed Bearings',#2378,$,$); -#2383=IFCCLASSIFICATIONREFERENCE($,'23-13 35 11 21','Vibration and Earthquake Controls',#2371,$,$); -#2384=IFCCLASSIFICATIONREFERENCE($,'23-13 35 13','Non Structural Framing Products',#2370,$,$); -#2385=IFCCLASSIFICATIONREFERENCE($,'23-13 35 15','Space Frames',#2370,$,$); -#2386=IFCCLASSIFICATIONREFERENCE($,'23-13 35 15 11','Booms Braces',#2385,$,$); -#2387=IFCCLASSIFICATIONREFERENCE($,'23-13 35 15 13','Couplers',#2385,$,$); -#2388=IFCCLASSIFICATIONREFERENCE($,'23-13 35 15 15','Complete Space Frames',#2385,$,$); -#2389=IFCCLASSIFICATIONREFERENCE($,'23-13 35 17','Geodesic Structures',#2370,$,$); -#2390=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19','Rafters, Beams, and Joists',#2370,$,$); -#2391=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 11','Trussed Rafters',#2390,$,$); -#2392=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 13','Trussed Beams and Joists',#2390,$,$); -#2393=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 13 11','Trussed Metal Joists',#2392,$,$); -#2394=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 13 13','Trussed Composite Joist Assemblies',#2392,$,$); -#2395=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 13 15','Trussed Metal Web Wood Joists',#2392,$,$); -#2396=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 13 17','Wood Trusses',#2392,$,$); -#2397=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 13 19','Metal Trusses',#2392,$,$); -#2398=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 15','Web Beams and Joists',#2390,$,$); -#2399=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 15 11','Wood Joists',#2398,$,$); -#2400=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 15 13','Wood Beams',#2398,$,$); -#2401=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 15 15','Heavy Timber Construction',#2398,$,$); -#2402=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 15 17','Engineered Wood Products',#2398,$,$); -#2403=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 17','Precast Concrete Beams',#2390,$,$); -#2404=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 17 11','Precast Concrete Doubletee Beams',#2403,$,$); -#2405=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 17 13','Precast Concrete Hollowcore Beams',#2403,$,$); -#2406=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 17 15','Precast Concrete Inverted Tee Beams',#2403,$,$); -#2407=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 17 17','Precast Concrete Spandrel Beams',#2403,$,$); -#2408=IFCCLASSIFICATIONREFERENCE($,'23-13 35 21','Structural Walls',#2370,$,$); -#2409=IFCCLASSIFICATIONREFERENCE($,'23-13 35 21 11','Concrete Structural Walls',#2408,$,$); -#2410=IFCCLASSIFICATIONREFERENCE($,'23-13 35 21 13','Masonry Structural Walls',#2408,$,$); -#2411=IFCCLASSIFICATIONREFERENCE($,'23-13 35 21 15','Wood Framed Structural Walls',#2408,$,$); -#2412=IFCCLASSIFICATIONREFERENCE($,'23-13 35 21 17','Metal Framed Structural Walls',#2408,$,$); -#2413=IFCCLASSIFICATIONREFERENCE($,'23-13 35 21 19','Structural Panels',#2408,$,$); -#2414=IFCCLASSIFICATIONREFERENCE($,'23-13 35 21 19 11','Cementitious Reinforced Structural Panels',#2413,$,$); -#2415=IFCCLASSIFICATIONREFERENCE($,'23-13 35 21 19 13','Stressed Skin Structural Panels',#2413,$,$); -#2416=IFCCLASSIFICATIONREFERENCE($,'23-13 35 21 19 15','Structural Insulated Panels',#2413,$,$); -#2417=IFCCLASSIFICATIONREFERENCE($,'23-13 35 21 21','Other Structural Walls',#2408,$,$); -#2418=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23','Structural Floors and Flat Roofs',#2370,$,$); -#2419=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 11','Structural Floor Decks',#2418,$,$); -#2420=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 11 11','Concrete Structural Floor Decks',#2419,$,$); -#2421=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 11 13','Metal Structural Floor Decks',#2419,$,$); -#2422=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 11 13 11','Raceway Deck Systems',#2421,$,$); -#2423=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 11 13 13','Acoustical Metal Floor Decks',#2421,$,$); -#2424=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 11 15','Wood Structural Floor Decks',#2419,$,$); -#2425=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 13','Structural Roof Decks',#2418,$,$); -#2426=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 13 11','Concrete Structural Roof Decks',#2425,$,$); -#2427=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 13 13','Metal Structural Roof Decks',#2425,$,$); -#2428=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 13 13 11','Acoustical Metal Roof Deck',#2427,$,$); -#2429=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 13 15','Wood Structural Roof Decks',#2425,$,$); -#2430=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 15','Structural Grating Floors',#2418,$,$); -#2431=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 17','Balconies and Overhang Units',#2418,$,$); -#2432=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 17 11','Balcony Components',#2431,$,$); -#2433=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 17 11 11','Balcony Holders and Mechanical Fasteners',#2432,$,$); -#2434=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 17 13','Concrete Balconies and Overhang Units',#2431,$,$); -#2435=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 17 15','Metal Balconies and Overhang Units',#2431,$,$); -#2436=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 17 17','Wood Balconies and Overhang Units',#2431,$,$); -#2437=IFCCLASSIFICATIONREFERENCE($,'23-13 35 25','Structural Profiled Roofs',#2370,$,$); -#2438=IFCCLASSIFICATIONREFERENCE($,'23-13 35 25 11','Prefabricated Shell Roofs',#2437,$,$); -#2439=IFCCLASSIFICATIONREFERENCE($,'23-13 35 25 13','Simulated Stones',#2437,$,$); -#2440=IFCCLASSIFICATIONREFERENCE($,'23-13 37 00','Multi-Function Exterior Coverings, Claddings, Linings',#1847,$,$); -#2441=IFCCLASSIFICATIONREFERENCE($,'23-13 37 11','Multi-Function Exterior Claddings',#2440,$,$); -#2442=IFCCLASSIFICATIONREFERENCE($,'23-13 37 13','Exterior Wall Cladding',#2440,$,$); -#2443=IFCCLASSIFICATIONREFERENCE($,'23-13 37 15','Exterior Siding',#2440,$,$); -#2444=IFCCLASSIFICATIONREFERENCE($,'23-13 37 15 11','Metal Exterior Siding',#2443,$,$); -#2445=IFCCLASSIFICATIONREFERENCE($,'23-13 37 15 13','Composition Exterior Siding',#2443,$,$); -#2446=IFCCLASSIFICATIONREFERENCE($,'23-13 37 15 15','Mineral Fiber Cement Exterior Siding',#2443,$,$); -#2447=IFCCLASSIFICATIONREFERENCE($,'23-13 37 15 17','Plastic Exterior Siding',#2443,$,$); -#2448=IFCCLASSIFICATIONREFERENCE($,'23-13 37 15 19','Wood Exterior Siding',#2443,$,$); -#2449=IFCCLASSIFICATIONREFERENCE($,'23-13 37 17','Multi Function Exterior Linings',#2440,$,$); -#2450=IFCCLASSIFICATIONREFERENCE($,'23-13 37 17 11','Sheathing Products',#2449,$,$); -#2451=IFCCLASSIFICATIONREFERENCE($,'23-13 37 19','Exterior Plasters',#2440,$,$); -#2452=IFCCLASSIFICATIONREFERENCE($,'23-13 37 21','Preformed Exterior Casings',#2440,$,$); -#2453=IFCCLASSIFICATIONREFERENCE($,'23-13 37 23','Ancillary Products for Coverings and Claddings',#2440,$,$); -#2454=IFCCLASSIFICATIONREFERENCE($,'23-13 37 23 11','Supports for Coverings and Claddings',#2453,$,$); -#2455=IFCCLASSIFICATIONREFERENCE($,'23-13 37 23 13','Mechanical Fasteners for Coverings and Claddings',#2453,$,$); -#2456=IFCCLASSIFICATIONREFERENCE($,'23-13 37 23 15','Movement and Dividing Joints for Coverings and Claddings',#2453,$,$); -#2457=IFCCLASSIFICATIONREFERENCE($,'23-13 37 23 17','Joint Coverings, Flashings, Tapes',#2453,$,$); -#2458=IFCCLASSIFICATIONREFERENCE($,'23-13 37 23 19','Reinforcements for Coverings and Claddings',#2453,$,$); -#2459=IFCCLASSIFICATIONREFERENCE($,'23-13 37 23 21','Trims, Edgings, Capping',#2453,$,$); -#2460=IFCCLASSIFICATIONREFERENCE($,'23-13 37 23 23','Spacers',#2453,$,$); -#2461=IFCCLASSIFICATIONREFERENCE($,'23-13 37 23 25','Profile Fillers',#2453,$,$); -#2462=IFCCLASSIFICATIONREFERENCE($,'23-13 37 23 27','Underlays, Linings, Separations',#2453,$,$); -#2463=IFCCLASSIFICATIONREFERENCE($,'23-13 37 23 29','Beddings, Adhesives for Coverings and Claddings',#2453,$,$); -#2464=IFCCLASSIFICATIONREFERENCE($,'23-13 37 23 31','Sealants for Coverings and Claddings',#2453,$,$); -#2465=IFCCLASSIFICATIONREFERENCE($,'23-13 39 00','Roof Coverings, Claddings, Linings',#1847,$,$); -#2466=IFCCLASSIFICATIONREFERENCE($,'23-13 39 11','Exterior Roof Panels',#2465,$,$); -#2467=IFCCLASSIFICATIONREFERENCE($,'23-13 39 11 11','Exterior Metal Roof Panels',#2466,$,$); -#2468=IFCCLASSIFICATIONREFERENCE($,'23-13 39 11 13','Exterior Plastic Roof Panels',#2466,$,$); -#2469=IFCCLASSIFICATIONREFERENCE($,'23-13 39 11 15','Exterior Wood Roof Panels',#2466,$,$); -#2470=IFCCLASSIFICATIONREFERENCE($,'23-13 39 11 17','Exterior Composite Roof Panels',#2466,$,$); -#2471=IFCCLASSIFICATIONREFERENCE($,'23-13 39 11 19','Exterior Faced Roof Panels',#2466,$,$); -#2472=IFCCLASSIFICATIONREFERENCE($,'23-13 39 11 21','Exterior Aggregate Coated Panels',#2466,$,$); -#2473=IFCCLASSIFICATIONREFERENCE($,'23-13 39 11 23','Exterior Porcelain Enameled Faced Panels',#2466,$,$); -#2474=IFCCLASSIFICATIONREFERENCE($,'23-13 39 11 25','Exterior Tile Faced Panels',#2466,$,$); -#2475=IFCCLASSIFICATIONREFERENCE($,'23-13 39 11 27','Exterior Fiber Reinforced Cementitious Panels',#2466,$,$); -#2476=IFCCLASSIFICATIONREFERENCE($,'23-13 39 11 29','Exterior Glass Fiber Reinforced Cementitious Panels',#2466,$,$); -#2477=IFCCLASSIFICATIONREFERENCE($,'23-13 39 11 31','Exterior Miner Fiber Reinforced Cementitious Panels',#2466,$,$); -#2478=IFCCLASSIFICATIONREFERENCE($,'23-13 39 13','Roof Underlayment',#2465,$,$); -#2479=IFCCLASSIFICATIONREFERENCE($,'23-13 39 15','Roof Shingles',#2465,$,$); -#2480=IFCCLASSIFICATIONREFERENCE($,'23-13 39 15 11','Asphalt Roof Shingles',#2479,$,$); -#2481=IFCCLASSIFICATIONREFERENCE($,'23-13 39 15 13','Fiberglass Reinforced Roof Shingles',#2479,$,$); -#2482=IFCCLASSIFICATIONREFERENCE($,'23-13 39 15 15','Metal Roof Shingles',#2479,$,$); -#2483=IFCCLASSIFICATIONREFERENCE($,'23-13 39 15 17','Mineral Fiber Cement Roof Shingles',#2479,$,$); -#2484=IFCCLASSIFICATIONREFERENCE($,'23-13 39 15 19','Plastic Roof Shingles',#2479,$,$); -#2485=IFCCLASSIFICATIONREFERENCE($,'23-13 39 15 21','Porcelain Enamel Roof Shingles',#2479,$,$); -#2486=IFCCLASSIFICATIONREFERENCE($,'23-13 39 15 23','Wood Shingles',#2479,$,$); -#2487=IFCCLASSIFICATIONREFERENCE($,'23-13 39 15 25','Concrete Roof Shingles',#2479,$,$); -#2488=IFCCLASSIFICATIONREFERENCE($,'23-13 39 17','Roof Tiles',#2465,$,$); -#2489=IFCCLASSIFICATIONREFERENCE($,'23-13 39 17 11','Clay Roof Tiles',#2488,$,$); -#2490=IFCCLASSIFICATIONREFERENCE($,'23-13 39 17 13','Concrete Roof Tiles',#2488,$,$); -#2491=IFCCLASSIFICATIONREFERENCE($,'23-13 39 17 15','Metal Roof Tiles',#2488,$,$); -#2492=IFCCLASSIFICATIONREFERENCE($,'23-13 39 17 17','Mineral Fiber Cement Roof Tiles',#2488,$,$); -#2493=IFCCLASSIFICATIONREFERENCE($,'23-13 39 17 19','Plastic Roof Tiles',#2488,$,$); -#2494=IFCCLASSIFICATIONREFERENCE($,'23-13 39 17 21','Ceramic Roof Tiles',#2488,$,$); -#2495=IFCCLASSIFICATIONREFERENCE($,'23-13 39 17 23','Tile Roof Mechanical Fasteners',#2488,$,$); -#2496=IFCCLASSIFICATIONREFERENCE($,'23-13 39 19','Natural Stone Roofing',#2465,$,$); -#2497=IFCCLASSIFICATIONREFERENCE($,'23-13 39 19 11','Roof Slates',#2496,$,$); -#2498=IFCCLASSIFICATIONREFERENCE($,'23-13 39 19 11 11','Slate Roof Mechanical Fasteners',#2497,$,$); -#2499=IFCCLASSIFICATIONREFERENCE($,'23-13 39 21','Shake Roofing',#2465,$,$); -#2500=IFCCLASSIFICATIONREFERENCE($,'23-13 39 21 11','Wood Shakes Roofing',#2499,$,$); -#2501=IFCCLASSIFICATIONREFERENCE($,'23-13 39 23','Flat Roofing',#2465,$,$); -#2502=IFCCLASSIFICATIONREFERENCE($,'23-13 39 23 11','Acoustical Metal Deck Roofing',#2501,$,$); -#2503=IFCCLASSIFICATIONREFERENCE($,'23-13 39 23 13','Structural Deck Roofing',#2501,$,$); -#2504=IFCCLASSIFICATIONREFERENCE($,'23-13 39 23 13 11','Concrete Structural Deck Roofing',#2503,$,$); -#2505=IFCCLASSIFICATIONREFERENCE($,'23-13 39 23 13 13','Metal Structural Deck Roofing',#2503,$,$); -#2506=IFCCLASSIFICATIONREFERENCE($,'23-13 39 23 15','Wood Decking Roofing',#2501,$,$); -#2507=IFCCLASSIFICATIONREFERENCE($,'23-13 39 25','Roof Finish Coating',#2465,$,$); -#2508=IFCCLASSIFICATIONREFERENCE($,'23-13 39 27','Roof Cladding',#2465,$,$); -#2509=IFCCLASSIFICATIONREFERENCE($,'23-13 39 27 11','Roof Cladding Sheets',#2508,$,$); -#2510=IFCCLASSIFICATIONREFERENCE($,'23-13 39 27 11 11','Metal Roof Panels',#2509,$,$); -#2511=IFCCLASSIFICATIONREFERENCE($,'23-13 39 27 11 13','Sheet Metal Roofing',#2509,$,$); -#2512=IFCCLASSIFICATIONREFERENCE($,'23-13 39 27 13','Roof Battens Cladding',#2508,$,$); -#2513=IFCCLASSIFICATIONREFERENCE($,'23-13 39 29','Roof Coverings',#2465,$,$); -#2514=IFCCLASSIFICATIONREFERENCE($,'23-13 39 29 11','Thatched Roofing',#2513,$,$); -#2515=IFCCLASSIFICATIONREFERENCE($,'23-13 39 29 13','Sod Roofing',#2513,$,$); -#2516=IFCCLASSIFICATIONREFERENCE($,'23-13 39 29 15','Vegetated Roof Covering',#2513,$,$); -#2517=IFCCLASSIFICATIONREFERENCE($,'23-13 39 29 15 11','Vegetated Roof Planting Modules',#2516,$,$); -#2518=IFCCLASSIFICATIONREFERENCE($,'23-13 39 29 17','Coated Foam Roof Covering',#2513,$,$); -#2519=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31','Roof Membranes',#2465,$,$); -#2520=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 11','Single Layer Roof Membranes',#2519,$,$); -#2521=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 11 11','Chlorinated Polyethylene (CPE) Single Layer Roof Membranes',#2520,$,$); -#2522=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 11 13','Chlorosulfonated Polyethylene (CSPE) Single Layer Roof Membranes',#2520,$,$); -#2523=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 11 15','Copolymer Alloy (CPA) Single Layer Roof Membranes',#2520,$,$); -#2524=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 11 17','Elastomeric Single Layer Roof Membranes',#2520,$,$); -#2525=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 11 19','Ethylene Interpolymer (EIP) Single Layer Roof Membranes',#2520,$,$); -#2526=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 11 21','Ethylene Propylene Diene Monomer (EPDM) Single Layer Roof Membranes',#2520,$,$); -#2527=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 11 23','Nitrile Butadiene Polymer (NBP) Single Layer Roof Membranes',#2520,$,$); -#2528=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 11 25','Polyisobutylene (PIB) Single Layer Roof Membranes',#2520,$,$); -#2529=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 11 27','Polyvinyl chloride (PVC) Single Layer Roof Membranes',#2520,$,$); -#2530=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 11 29','Thermoplastic Alloy (TPA) Single Layer Roof Membranes',#2520,$,$); -#2531=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 11 31','Thermoplastic Single Layer Roof Membranes',#2520,$,$); -#2532=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 13','Multi Layer Roof Membranes',#2519,$,$); -#2533=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 13 11','Asphalt Multi Layer Roof Membranes',#2532,$,$); -#2534=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 13 13','Built Up Bituminous Multi Layer Roof Membranes',#2532,$,$); -#2535=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 13 15','Coal Tar Multi Layer Roof Membranes',#2532,$,$); -#2536=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 13 17','Cold Applied Bituminous Multi Layer Roof Membranes',#2532,$,$); -#2537=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 13 19','Cold Applied Mastic Multi Layer Roof Membranes',#2532,$,$); -#2538=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 13 21','Glass Fiber Reinforced Asphalt Emulsion Multi Layer Roof Membranes',#2532,$,$); -#2539=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 13 23','Modified Bituminous Multi Layer Roof Membranes',#2532,$,$); -#2540=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 15','Fluid Applied Roofing',#2519,$,$); -#2541=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 17','Coated Foam Roofing',#2519,$,$); -#2542=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 19','Roll Roofing',#2519,$,$); -#2543=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33','Roof Decking',#2465,$,$); -#2544=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33 11','Cementitious Deck Roofing',#2543,$,$); -#2545=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33 11 11','Cementitious Composite Insulation Deck Roofing',#2544,$,$); -#2546=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33 11 13','Cementitious Lightweight Cellular Deck Roofing',#2544,$,$); -#2547=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33 11 15','Cementitious Lightweight Insulating Deck Roofing',#2544,$,$); -#2548=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33 13','Lightweight Concrete Roofing Insulation',#2543,$,$); -#2549=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33 13 11','Composite Concrete and Insulation Deck Roofing',#2548,$,$); -#2550=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33 13 13','Lightweight Cellular Concrete Deck Roofing',#2548,$,$); -#2551=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33 13 15','Lightweight Insulating Concrete Deck Roofing',#2548,$,$); -#2552=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33 15','Concrete Deck Roofing',#2543,$,$); -#2553=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33 15 11','Concrete Composite Insulation Deck Roofing',#2552,$,$); -#2554=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33 15 13','Concrete Lightweight Cellular Deck Roofing',#2552,$,$); -#2555=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33 15 15','Concrete Lightweight Insulating Deck Roofing',#2552,$,$); -#2556=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33 17','Concrete Roof Topping',#2543,$,$); -#2557=IFCCLASSIFICATIONREFERENCE($,'23-13 39 35','Roof Finishing Coatings',#2465,$,$); -#2558=IFCCLASSIFICATIONREFERENCE($,'23-13 39 37','Renovation Products for Roof Coverings and Claddings',#2465,$,$); -#2559=IFCCLASSIFICATIONREFERENCE($,'23-13 41 00','Roof Specialties and Accessories',#1847,$,$); -#2560=IFCCLASSIFICATIONREFERENCE($,'23-13 41 11','Roof Edgings and Trims',#2559,$,$); -#2561=IFCCLASSIFICATIONREFERENCE($,'23-13 41 11 11','Roof Copings',#2560,$,$); -#2562=IFCCLASSIFICATIONREFERENCE($,'23-13 41 11 13','Roof Counterflashing Systems',#2560,$,$); -#2563=IFCCLASSIFICATIONREFERENCE($,'23-13 41 11 15','Roof Gravel Stops',#2560,$,$); -#2564=IFCCLASSIFICATIONREFERENCE($,'23-13 41 11 17','Roof Fascias',#2560,$,$); -#2565=IFCCLASSIFICATIONREFERENCE($,'23-13 41 11 19','Roof Reglets',#2560,$,$); -#2566=IFCCLASSIFICATIONREFERENCE($,'23-13 41 11 21','Roof Scuppers',#2560,$,$); -#2567=IFCCLASSIFICATIONREFERENCE($,'23-13 41 13','Roof Flashings',#2559,$,$); -#2568=IFCCLASSIFICATIONREFERENCE($,'23-13 41 13 11','Laminated Sheet Flexible Roof Flashings',#2567,$,$); -#2569=IFCCLASSIFICATIONREFERENCE($,'23-13 41 13 13','Modified Bituminous Sheet Flexible Roof Flashings',#2567,$,$); -#2570=IFCCLASSIFICATIONREFERENCE($,'23-13 41 13 15','Plastic Sheet Flexible Roof Flashings',#2567,$,$); -#2571=IFCCLASSIFICATIONREFERENCE($,'23-13 41 13 17','Rubber Sheet Flexible Roof Flashings',#2567,$,$); -#2572=IFCCLASSIFICATIONREFERENCE($,'23-13 41 13 19','Self Adhering Sheet Flexible Roof Flashings',#2567,$,$); -#2573=IFCCLASSIFICATIONREFERENCE($,'23-13 41 13 21','Roof Vent Flashings',#2567,$,$); -#2574=IFCCLASSIFICATIONREFERENCE($,'23-13 41 13 23','Roof Flashing Drip Caps',#2567,$,$); -#2575=IFCCLASSIFICATIONREFERENCE($,'23-13 41 13 25','Roof Penetration Flashings',#2567,$,$); -#2576=IFCCLASSIFICATIONREFERENCE($,'23-13 41 15','Roof Expansion Joints',#2559,$,$); -#2577=IFCCLASSIFICATIONREFERENCE($,'23-13 41 17','Roof Vents',#2559,$,$); -#2578=IFCCLASSIFICATIONREFERENCE($,'23-13 41 17 11','Roof Relief Vents',#2577,$,$); -#2579=IFCCLASSIFICATIONREFERENCE($,'23-13 41 17 13','Roof Ridge Vents',#2577,$,$); -#2580=IFCCLASSIFICATIONREFERENCE($,'23-13 41 17 15','Roof Smoke Vents',#2577,$,$); -#2581=IFCCLASSIFICATIONREFERENCE($,'23-13 41 17 17','Gravity Roof Vents',#2577,$,$); -#2582=IFCCLASSIFICATIONREFERENCE($,'23-13 41 17 19','Automatic Roof Vents',#2577,$,$); -#2583=IFCCLASSIFICATIONREFERENCE($,'23-13 41 17 21','Fire Vents',#2577,$,$); -#2584=IFCCLASSIFICATIONREFERENCE($,'23-13 41 19','Roof Walkways',#2559,$,$); -#2585=IFCCLASSIFICATIONREFERENCE($,'23-13 41 19 11','Roof Pavers',#2584,$,$); -#2586=IFCCLASSIFICATIONREFERENCE($,'23-13 41 19 11 11','Precast Concrete Roof Pavers',#2585,$,$); -#2587=IFCCLASSIFICATIONREFERENCE($,'23-13 41 19 11 13','Pedestals Roof Pavers',#2585,$,$); -#2588=IFCCLASSIFICATIONREFERENCE($,'23-13 41 19 13','Roof Treads',#2584,$,$); -#2589=IFCCLASSIFICATIONREFERENCE($,'23-13 41 19 13 11','Rubber Roof Treads',#2588,$,$); -#2590=IFCCLASSIFICATIONREFERENCE($,'23-13 41 21','Roof Snow Guards',#2559,$,$); -#2591=IFCCLASSIFICATIONREFERENCE($,'23-13 41 23','Roof Piping Portals',#2559,$,$); -#2592=IFCCLASSIFICATIONREFERENCE($,'23-13 41 25','Roof Domes',#2559,$,$); -#2593=IFCCLASSIFICATIONREFERENCE($,'23-13 41 27','Roof Turrets',#2559,$,$); -#2594=IFCCLASSIFICATIONREFERENCE($,'23-13 41 29','Roof Lanterns',#2559,$,$); -#2595=IFCCLASSIFICATIONREFERENCE($,'23-13 41 31','Roof Curb',#2559,$,$); -#2596=IFCCLASSIFICATIONREFERENCE($,'23-13 41 31 11','Structural Roof Curb',#2595,$,$); -#2597=IFCCLASSIFICATIONREFERENCE($,'23-13 41 31 13','Acoustical Roof Curb',#2595,$,$); -#2598=IFCCLASSIFICATIONREFERENCE($,'23-13 41 31 15','Manufactured Roof Curbs',#2595,$,$); -#2599=IFCCLASSIFICATIONREFERENCE($,'23-13 41 33','Roof Gutters',#2559,$,$); -#2600=IFCCLASSIFICATIONREFERENCE($,'23-13 41 35','Roof Soffits',#2559,$,$); -#2601=IFCCLASSIFICATIONREFERENCE($,'23-13 41 37','Roof Splash Blocks',#2559,$,$); -#2602=IFCCLASSIFICATIONREFERENCE($,'23-13 41 39','Roof Drains',#2559,$,$); -#2603=IFCCLASSIFICATIONREFERENCE($,'23-13 41 39 11','Roof Downspouts',#2602,$,$); -#2604=IFCCLASSIFICATIONREFERENCE($,'23-13 41 39 13','Roof Drains With Strainer',#2602,$,$); -#2605=IFCCLASSIFICATIONREFERENCE($,'23-13 41 39 15','Roof Drains Without Strainer',#2602,$,$); -#2606=IFCCLASSIFICATIONREFERENCE($,'23-13 41 39 17','Eavestroughs',#2602,$,$); -#2607=IFCCLASSIFICATIONREFERENCE($,'23-13 41 39 17 11','Mechanical Fasteners for Downspouts',#2606,$,$); -#2608=IFCCLASSIFICATIONREFERENCE($,'23-13 41 39 17 13','Downspout Strainers',#2606,$,$); -#2609=IFCCLASSIFICATIONREFERENCE($,'23-13 41 39 19','Siphonic Roof Drains',#2602,$,$); -#2610=IFCCLASSIFICATIONREFERENCE($,'23-15 00 00','Interior and Finish Products',#1604,$,$); -#2611=IFCCLASSIFICATIONREFERENCE($,'23-15 11 00','Space Division Products',#2610,$,$); -#2612=IFCCLASSIFICATIONREFERENCE($,'23-15 11 11','Fixed Partitions',#2611,$,$); -#2613=IFCCLASSIFICATIONREFERENCE($,'23-15 11 11 11','Gypsum Board Fixed Partitions',#2612,$,$); -#2614=IFCCLASSIFICATIONREFERENCE($,'23-15 11 11 11 11','Metal Framed Gypsum Board Fixed Partitions',#2613,$,$); -#2615=IFCCLASSIFICATIONREFERENCE($,'23-15 11 11 11 13','Wood Framed Gypsum Board Fixed Partitions',#2613,$,$); -#2616=IFCCLASSIFICATIONREFERENCE($,'23-15 11 11 13','Plaster Fixed Partitions',#2612,$,$); -#2617=IFCCLASSIFICATIONREFERENCE($,'23-15 11 11 13 11','Gypsum Plaster Fixed Partitions',#2616,$,$); -#2618=IFCCLASSIFICATIONREFERENCE($,'23-15 11 11 13 13','Portland Cement Plaster Fixed Partitions',#2616,$,$); -#2619=IFCCLASSIFICATIONREFERENCE($,'23-15 11 11 13 15','Metal Framed Plaster Fixed Partitions',#2616,$,$); -#2620=IFCCLASSIFICATIONREFERENCE($,'23-15 11 11 13 17','Wood Framed Plaster Fixed Partitions',#2616,$,$); -#2621=IFCCLASSIFICATIONREFERENCE($,'23-15 11 11 15','Masonry Fixed Partitions',#2612,$,$); -#2622=IFCCLASSIFICATIONREFERENCE($,'23-15 11 13','Demountable Partitions',#2611,$,$); -#2623=IFCCLASSIFICATIONREFERENCE($,'23-15 11 13 11','General Demountable Partitions',#2622,$,$); -#2624=IFCCLASSIFICATIONREFERENCE($,'23-15 11 13 11 11','Demountable Partitions Component',#2623,$,$); -#2625=IFCCLASSIFICATIONREFERENCE($,'23-15 11 13 11 11 11','Partition Frames',#2624,$,$); -#2626=IFCCLASSIFICATIONREFERENCE($,'23-15 11 13 11 11 13','Partition Infill Panels',#2624,$,$); -#2627=IFCCLASSIFICATIONREFERENCE($,'23-15 11 13 11 11 15','Mechanical Fasteners for Partitions',#2624,$,$); -#2628=IFCCLASSIFICATIONREFERENCE($,'23-15 11 13 11 11 17','Joint Fillers and Tapes',#2624,$,$); -#2629=IFCCLASSIFICATIONREFERENCE($,'23-15 11 13 11 13','Gypsum Board Demountable Partitions',#2623,$,$); -#2630=IFCCLASSIFICATIONREFERENCE($,'23-15 11 13 11 15','Metal Demountable Partitions',#2623,$,$); -#2631=IFCCLASSIFICATIONREFERENCE($,'23-15 11 13 11 17','Wood Demountable Partitions',#2623,$,$); -#2632=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15','Sanitary Partitions and Cubicles',#2611,$,$); -#2633=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 11','Toilet Compartments and Urinal Screens',#2632,$,$); -#2634=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 11 11','Metal Toilet Compartment and Urinal Screens',#2633,$,$); -#2635=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 11 13','Plastic Laminate Toilet Compartment and Urinal Screens',#2633,$,$); -#2636=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 11 15','Plastic Toilet Compartment and Urinal Screens',#2633,$,$); -#2637=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 11 17','Particleboard Toilet Compartment and Urinal Screens',#2633,$,$); -#2638=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 11 19','Stone Toilet Compartment and Urinal Screens',#2633,$,$); -#2639=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 13','Shower and Dressing Compartments',#2632,$,$); -#2640=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 13 11','Metal Shower and Dressing Compartments',#2639,$,$); -#2641=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 13 13','Plastic Laminate Shower and Dressing Compartments',#2639,$,$); -#2642=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 13 15','Plastic Shower and Dressing Compartments',#2639,$,$); -#2643=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 13 17','Particleboard Shower and Dressing Compartments',#2639,$,$); -#2644=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 13 19','Stone Shower and Dressing Compartments',#2639,$,$); -#2645=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 15','Cubicles',#2632,$,$); -#2646=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 15 11','Cubicle Curtains',#2645,$,$); -#2647=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 15 13','Cubicle Track and Hardware',#2645,$,$); -#2648=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 17','Storage Wall Partitions and Compartments',#2632,$,$); -#2649=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 17 11','Wire Mesh Partitions',#2648,$,$); -#2650=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 19','Modular Corridor Linings',#2632,$,$); -#2651=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 21','Combined Partitions and Ceilings',#2632,$,$); -#2652=IFCCLASSIFICATIONREFERENCE($,'23-15 11 17','Operable Partitions',#2611,$,$); -#2653=IFCCLASSIFICATIONREFERENCE($,'23-15 11 17 11','Horizontally Sliding Partitions',#2652,$,$); -#2654=IFCCLASSIFICATIONREFERENCE($,'23-15 11 17 13','Folding Panel Partitions',#2652,$,$); -#2655=IFCCLASSIFICATIONREFERENCE($,'23-15 11 17 15','Accordion Folding Partitions',#2652,$,$); -#2656=IFCCLASSIFICATIONREFERENCE($,'23-15 11 17 17','Coiling Partitions',#2652,$,$); -#2657=IFCCLASSIFICATIONREFERENCE($,'23-15 11 17 19','Vertically Sliding Room Dividers',#2652,$,$); -#2658=IFCCLASSIFICATIONREFERENCE($,'23-15 13 00','Multi-Function Interior Coverings, Claddings, Linings',#2610,$,$); -#2659=IFCCLASSIFICATIONREFERENCE($,'23-15 13 11','Multi Function Interior Claddings',#2658,$,$); -#2660=IFCCLASSIFICATIONREFERENCE($,'23-15 13 13','Interior Wall and Ceiling Cladding',#2658,$,$); -#2661=IFCCLASSIFICATIONREFERENCE($,'23-15 13 15','Interior Siding',#2658,$,$); -#2662=IFCCLASSIFICATIONREFERENCE($,'23-15 13 15 11','Metal Interior Siding',#2661,$,$); -#2663=IFCCLASSIFICATIONREFERENCE($,'23-15 13 15 13','Composition Interior Siding',#2661,$,$); -#2664=IFCCLASSIFICATIONREFERENCE($,'23-15 13 15 15','Mineral Fiber Cement Interior Siding',#2661,$,$); -#2665=IFCCLASSIFICATIONREFERENCE($,'23-15 13 15 17','Plastic Interior Siding',#2661,$,$); -#2666=IFCCLASSIFICATIONREFERENCE($,'23-15 13 15 19','Wood Interior Siding',#2661,$,$); -#2667=IFCCLASSIFICATIONREFERENCE($,'23-15 13 17','Multi Function Interior Linings',#2658,$,$); -#2668=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19','Wall Panels',#2658,$,$); -#2669=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19 11','Metal Wall Panels',#2668,$,$); -#2670=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19 13','Plastic Wall Panels',#2668,$,$); -#2671=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19 15','Wood Wall Panels',#2668,$,$); -#2672=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19 17','Composite Wall Panels',#2668,$,$); -#2673=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19 19','Faced Wall Panels',#2668,$,$); -#2674=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19 21','Aggregate Coated Wall Panels',#2668,$,$); -#2675=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19 23','Porcelain Enameled Faced Wall Panels',#2668,$,$); -#2676=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19 25','Tile Faced Wall Panels',#2668,$,$); -#2677=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19 27','Fiber Reinforced Cementitious Wall Panels',#2668,$,$); -#2678=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19 29','Glass Fiber Reinforced Cementitious Wall Panels',#2668,$,$); -#2679=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19 31','Miner Fiber Reinforced Cementitious Wall Panels',#2668,$,$); -#2680=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19 33','Flexible Wood Wall Sheets',#2668,$,$); -#2681=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19 35','Acoustical Wall Treatment',#2668,$,$); -#2682=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21','Ceiling Panels',#2658,$,$); -#2683=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21 11','Metal Ceiling Panels',#2682,$,$); -#2684=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21 13','Plastic Ceiling Panels',#2682,$,$); -#2685=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21 15','Wood Ceiling Panels',#2682,$,$); -#2686=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21 17','Composite Ceiling Panels',#2682,$,$); -#2687=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21 19','Faced Ceiling Panels',#2682,$,$); -#2688=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21 21','Aggregate Coated Ceiling Panels',#2682,$,$); -#2689=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21 23','Porcelain Enameled Faced Ceiling Panels',#2682,$,$); -#2690=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21 25','Tile Faced Ceiling Panels',#2682,$,$); -#2691=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21 27','Fiber Reinforced Cementitious Ceiling Panels',#2682,$,$); -#2692=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21 29','Glass Fiber Reinforced Cementitious Ceiling Panels',#2682,$,$); -#2693=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21 31','Miner Fiber Reinforced Cementitious Ceiling Panels',#2682,$,$); -#2694=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21 33','Flexible Wood Ceiling Sheets',#2682,$,$); -#2695=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21 35','Acoustical Ceiling Treatment',#2682,$,$); -#2696=IFCCLASSIFICATIONREFERENCE($,'23-15 13 23','Interior Plasters',#2658,$,$); -#2697=IFCCLASSIFICATIONREFERENCE($,'23-15 13 25','Preformed Interior Casings',#2658,$,$); -#2698=IFCCLASSIFICATIONREFERENCE($,'23-15 15 00','Wall Coverings, Claddings, Linings',#2610,$,$); -#2699=IFCCLASSIFICATIONREFERENCE($,'23-15 15 11','Wall Cladding Sections',#2698,$,$); -#2700=IFCCLASSIFICATIONREFERENCE($,'23-15 15 11 11','Metal Wall Cladding Sections',#2699,$,$); -#2701=IFCCLASSIFICATIONREFERENCE($,'23-15 15 11 13','Wood Wall Cladding Sections',#2699,$,$); -#2702=IFCCLASSIFICATIONREFERENCE($,'23-15 15 11 15','Plastics Wall Cladding Sections',#2699,$,$); -#2703=IFCCLASSIFICATIONREFERENCE($,'23-15 15 11 17','Other Wall Cladding Sections',#2699,$,$); -#2704=IFCCLASSIFICATIONREFERENCE($,'23-15 15 13','Wall Tiles',#2698,$,$); -#2705=IFCCLASSIFICATIONREFERENCE($,'23-15 15 13 11','Natural Stone Wall Tiles',#2704,$,$); -#2706=IFCCLASSIFICATIONREFERENCE($,'23-15 15 13 13','Reconstituted Stone Wall Tiles',#2704,$,$); -#2707=IFCCLASSIFICATIONREFERENCE($,'23-15 15 13 15','Cementitious Wall Tiles',#2704,$,$); -#2708=IFCCLASSIFICATIONREFERENCE($,'23-15 15 13 17','Clay Based Wall Tiles',#2704,$,$); -#2709=IFCCLASSIFICATIONREFERENCE($,'23-15 15 13 19','Metal Wall Tiles',#2704,$,$); -#2710=IFCCLASSIFICATIONREFERENCE($,'23-15 15 13 21','Vegetable Based Wall Tiles',#2704,$,$); -#2711=IFCCLASSIFICATIONREFERENCE($,'23-15 15 13 23','Plastics Wall Tiles',#2704,$,$); -#2712=IFCCLASSIFICATIONREFERENCE($,'23-15 15 13 25','Other Wall Tiles',#2704,$,$); -#2713=IFCCLASSIFICATIONREFERENCE($,'23-15 15 15','Wall Cladding Panels',#2698,$,$); -#2714=IFCCLASSIFICATIONREFERENCE($,'23-15 15 15 11','Wall Stone Facing',#2713,$,$); -#2715=IFCCLASSIFICATIONREFERENCE($,'23-15 15 15 13','Cementitious Wall Cladding Panels',#2713,$,$); -#2716=IFCCLASSIFICATIONREFERENCE($,'23-15 15 15 13 11','Precast Concrete Wall Cladding Panels',#2715,$,$); -#2717=IFCCLASSIFICATIONREFERENCE($,'23-15 15 15 15','Metal Wall Cladding Panels',#2713,$,$); -#2718=IFCCLASSIFICATIONREFERENCE($,'23-15 15 15 17','Wood Based Wall Cladding Panels',#2713,$,$); -#2719=IFCCLASSIFICATIONREFERENCE($,'23-15 15 15 19','Plastic Wall Cladding Panels',#2713,$,$); -#2720=IFCCLASSIFICATIONREFERENCE($,'23-15 15 15 19 11','Plastic Wall Cladding Blocks',#2719,$,$); -#2721=IFCCLASSIFICATIONREFERENCE($,'23-15 15 15 21','Other Wall Cladding Panels',#2713,$,$); -#2722=IFCCLASSIFICATIONREFERENCE($,'23-15 15 17','Wall Cladding Sheets',#2698,$,$); -#2723=IFCCLASSIFICATIONREFERENCE($,'23-15 15 17 11','Fiber Based Wall Cladding Sheets',#2722,$,$); -#2724=IFCCLASSIFICATIONREFERENCE($,'23-15 15 17 13','Metal Wall Cladding Sheets',#2722,$,$); -#2725=IFCCLASSIFICATIONREFERENCE($,'23-15 15 17 15','Plastic Wall Cladding Sheets',#2722,$,$); -#2726=IFCCLASSIFICATIONREFERENCE($,'23-15 15 17 17','Fiberglass Reinforced Panels',#2722,$,$); -#2727=IFCCLASSIFICATIONREFERENCE($,'23-15 15 19','Wall Coverings',#2698,$,$); -#2728=IFCCLASSIFICATIONREFERENCE($,'23-15 15 19 11','Wallpaper',#2727,$,$); -#2729=IFCCLASSIFICATIONREFERENCE($,'23-15 15 19 13','Wall Fabrics',#2727,$,$); -#2730=IFCCLASSIFICATIONREFERENCE($,'23-15 15 19 15','Plastic Wall Coverings',#2727,$,$); -#2731=IFCCLASSIFICATIONREFERENCE($,'23-15 15 19 17','Cork Wall Covering',#2727,$,$); -#2732=IFCCLASSIFICATIONREFERENCE($,'23-15 15 19 19','Vinyl Coated Fabric Wall Covering',#2727,$,$); -#2733=IFCCLASSIFICATIONREFERENCE($,'23-15 15 19 21','Vinyl Wall Covering',#2727,$,$); -#2734=IFCCLASSIFICATIONREFERENCE($,'23-15 15 19 23','Wall Carpet',#2727,$,$); -#2735=IFCCLASSIFICATIONREFERENCE($,'23-15 15 19 25','Wall Veneers',#2727,$,$); -#2736=IFCCLASSIFICATIONREFERENCE($,'23-15 15 21','Wall Blocks',#2698,$,$); -#2737=IFCCLASSIFICATIONREFERENCE($,'23-15 15 23','Wall Linings',#2698,$,$); -#2738=IFCCLASSIFICATIONREFERENCE($,'23-15 15 25','Wall Finish Coatings',#2698,$,$); -#2739=IFCCLASSIFICATIONREFERENCE($,'23-15 15 27','Renders',#2698,$,$); -#2740=IFCCLASSIFICATIONREFERENCE($,'23-15 15 29','Acoustical Wall Finishes',#2698,$,$); -#2741=IFCCLASSIFICATIONREFERENCE($,'23-15 15 31','Wall Specialties and Trim',#2698,$,$); -#2742=IFCCLASSIFICATIONREFERENCE($,'23-15 15 31 11','Wall Pilasters',#2741,$,$); -#2743=IFCCLASSIFICATIONREFERENCE($,'23-15 15 31 13','Wall Niches',#2741,$,$); -#2744=IFCCLASSIFICATIONREFERENCE($,'23-15 15 31 15','Wall Moldings',#2741,$,$); -#2745=IFCCLASSIFICATIONREFERENCE($,'23-15 15 31 17','Renovating Wall Coverings',#2741,$,$); -#2746=IFCCLASSIFICATIONREFERENCE($,'23-15 15 31 19','Renovating Wall Claddings',#2741,$,$); -#2747=IFCCLASSIFICATIONREFERENCE($,'23-15 15 33','Wall Finish Restoration Products',#2698,$,$); -#2748=IFCCLASSIFICATIONREFERENCE($,'23-15 15 35','Security Wall Protection Products',#2698,$,$); -#2749=IFCCLASSIFICATIONREFERENCE($,'23-15 15 35 11','Blast Resistant Wall Exteriors',#2748,$,$); -#2750=IFCCLASSIFICATIONREFERENCE($,'23-15 15 35 13','Blast Resistant Wall Interiors',#2748,$,$); -#2751=IFCCLASSIFICATIONREFERENCE($,'23-15 17 00','Floor Coverings',#2610,$,$); -#2752=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11','Flooring Specialties and Accessories',#2751,$,$); -#2753=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 11','Floor Toppings',#2752,$,$); -#2754=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 11 11','Concrete Floor Toppings',#2753,$,$); -#2755=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 13','Floor Underlayments',#2752,$,$); -#2756=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 13 11','Cementitious Floor Underlayments',#2755,$,$); -#2757=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 13 11 11','Gypsum Floor Underlayments',#2756,$,$); -#2758=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 13 11 13','Portland Cement Floor Underlayments',#2756,$,$); -#2759=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 13 13','Acoustical Underlayments',#2755,$,$); -#2760=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 13 15','Crack Prevention Mat Underlayments',#2755,$,$); -#2761=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 15','Floor Treatment Products',#2752,$,$); -#2762=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 15 11','Floor Sealers',#2761,$,$); -#2763=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 15 13','Floor Hardeners',#2761,$,$); -#2764=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 15 15','Slip Resistant Floor Treatment',#2761,$,$); -#2765=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 15 17','Static Resistant Floor Treatment',#2761,$,$); -#2766=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 15 19','Acid Resistant Floor Treatment',#2761,$,$); -#2767=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 17','Floor Base and Accessories',#2752,$,$); -#2768=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 17 11','Base and Accessories for Floor Coverings',#2767,$,$); -#2769=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 17 13','Acoustic Floor Mountings',#2767,$,$); -#2770=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 19','Floor Mats and Grilles',#2752,$,$); -#2771=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 19 11','Floor Mats',#2770,$,$); -#2772=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 19 13','Floor Grilles',#2770,$,$); -#2773=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 19 15','Floor Gratings',#2770,$,$); -#2774=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 21','Flooring Restoration Products',#2752,$,$); -#2775=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 21 11','Bamboo',#2774,$,$); -#2776=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13','Floor Covering Strips, Tiles, Blocks, and Slabs',#2751,$,$); -#2777=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 11','Wood Flooring',#2776,$,$); -#2778=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 11 11','Cushioned Wood Flooring Assemblies',#2777,$,$); -#2779=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 11 13','Mastic Set Wood Flooring Assemblies',#2777,$,$); -#2780=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 11 15','Resilient Wood Flooring Assemblies',#2777,$,$); -#2781=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 11 17','Wood Athletic Flooring',#2777,$,$); -#2782=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 11 19','Wood Block Flooring',#2777,$,$); -#2783=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 11 21','Wood Composition Flooring',#2777,$,$); -#2784=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 11 23','Wood Parquet Flooring',#2777,$,$); -#2785=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 11 25','Wood Strip Flooring',#2777,$,$); -#2786=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 13','Tile Flooring',#2776,$,$); -#2787=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 13 11','Clay Based Flooring',#2786,$,$); -#2788=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 13 13','Ceramic Tile Flooring',#2786,$,$); -#2789=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 13 13 11','Ceramic Mosaic Tile Flooring',#2788,$,$); -#2790=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 13 13 13','Conductive Tile Flooring',#2788,$,$); -#2791=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 13 15','Quarry Tile Flooring',#2786,$,$); -#2792=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 13 17','Chemical Resistant Quarry Tile Flooring',#2786,$,$); -#2793=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 13 17 11','Porcelain Tile Flooring',#2792,$,$); -#2794=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 13 17 13','Glass Mosaic Tile Flooring',#2792,$,$); -#2795=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 13 17 15','Plastic Tile Flooring',#2792,$,$); -#2796=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 13 17 17','Metal Tile Flooring',#2792,$,$); -#2797=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 13 17 19','Natural Cut Stone Tile Flooring',#2792,$,$); -#2798=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 13 17 21','Tile Flooring Restoration Products',#2792,$,$); -#2799=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 15','Terrazzo Flooring',#2776,$,$); -#2800=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 15 11','Portland Cement Terrazzo Flooring',#2799,$,$); -#2801=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 15 13','Precast Terrazzo Flooring',#2799,$,$); -#2802=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 15 15','Conductive Terrazzo Flooring',#2799,$,$); -#2803=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 15 17','Plastic matrix Terrazzo Flooring',#2799,$,$); -#2804=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 15 19','Terrazzo Flooring Restoration Products',#2799,$,$); -#2805=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 17','Masonry Flooring',#2776,$,$); -#2806=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 17 11','Brick Flooring',#2805,$,$); -#2807=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 17 11 11','Chemical Resistant Brick Flooring',#2806,$,$); -#2808=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 17 13','Stone Flooring',#2805,$,$); -#2809=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 17 15','Other Masonry Flooring',#2805,$,$); -#2810=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 19','Precast Tile and Slab Flooring',#2776,$,$); -#2811=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 21','Metal Flooring',#2776,$,$); -#2812=IFCCLASSIFICATIONREFERENCE($,'23-15 17 15','Resilient Flooring',#2751,$,$); -#2813=IFCCLASSIFICATIONREFERENCE($,'23-15 17 15 11','Cork Flooring',#2812,$,$); -#2814=IFCCLASSIFICATIONREFERENCE($,'23-15 17 15 13','Plastic Flooring',#2812,$,$); -#2815=IFCCLASSIFICATIONREFERENCE($,'23-15 17 15 15','Rubber Flooring',#2812,$,$); -#2816=IFCCLASSIFICATIONREFERENCE($,'23-15 17 15 17','Linoleum Flooring',#2812,$,$); -#2817=IFCCLASSIFICATIONREFERENCE($,'23-15 17 15 19','Mechanical Fasteners for Resilient Floor Coverings',#2812,$,$); -#2818=IFCCLASSIFICATIONREFERENCE($,'23-15 17 15 19 11','Floor Clips',#2817,$,$); -#2819=IFCCLASSIFICATIONREFERENCE($,'23-15 17 15 19 13','Carpet Grippers',#2817,$,$); -#2820=IFCCLASSIFICATIONREFERENCE($,'23-15 17 15 19 15','Stair Rods',#2817,$,$); -#2821=IFCCLASSIFICATIONREFERENCE($,'23-15 17 15 21','Other Resilient Flooring',#2812,$,$); -#2822=IFCCLASSIFICATIONREFERENCE($,'23-15 17 17','Carpet Flooring',#2751,$,$); -#2823=IFCCLASSIFICATIONREFERENCE($,'23-15 17 17 11','Carpet Cushions',#2822,$,$); -#2824=IFCCLASSIFICATIONREFERENCE($,'23-15 17 17 13','Carpet Tiles',#2822,$,$); -#2825=IFCCLASSIFICATIONREFERENCE($,'23-15 17 17 15','Indoor Carpet Flooring',#2822,$,$); -#2826=IFCCLASSIFICATIONREFERENCE($,'23-15 17 17 17','Outdoor Carpet Flooring',#2822,$,$); -#2827=IFCCLASSIFICATIONREFERENCE($,'23-15 17 17 19','Sheet Carpet Flooring',#2822,$,$); -#2828=IFCCLASSIFICATIONREFERENCE($,'23-15 17 19','Preformed Flooring Equipment Systems',#2751,$,$); -#2829=IFCCLASSIFICATIONREFERENCE($,'23-15 17 19 11','Floating Floors',#2828,$,$); -#2830=IFCCLASSIFICATIONREFERENCE($,'23-15 17 19 13','Portable Floors',#2828,$,$); -#2831=IFCCLASSIFICATIONREFERENCE($,'23-15 17 19 15','Convertible Floors',#2828,$,$); -#2832=IFCCLASSIFICATIONREFERENCE($,'23-15 17 19 17','Gymnasium or Dance Flooring',#2828,$,$); -#2833=IFCCLASSIFICATIONREFERENCE($,'23-15 17 21','Access Flooring Components',#2751,$,$); -#2834=IFCCLASSIFICATIONREFERENCE($,'23-15 17 21 11','Access Floor Frames',#2833,$,$); -#2835=IFCCLASSIFICATIONREFERENCE($,'23-15 17 21 13','Access Floor Infill Panels',#2833,$,$); -#2836=IFCCLASSIFICATIONREFERENCE($,'23-15 17 23','Rigid Grid Access Flooring',#2751,$,$); -#2837=IFCCLASSIFICATIONREFERENCE($,'23-15 17 25','Snap On Stringer Access Flooring',#2751,$,$); -#2838=IFCCLASSIFICATIONREFERENCE($,'23-15 17 27','Stringerless Access Flooring',#2751,$,$); -#2839=IFCCLASSIFICATIONREFERENCE($,'23-15 17 29','Floor Finishing Coatings',#2751,$,$); -#2840=IFCCLASSIFICATIONREFERENCE($,'23-15 17 29 11','Industrial Floor Coatings',#2839,$,$); -#2841=IFCCLASSIFICATIONREFERENCE($,'23-15 17 29 13','Fluid Applied Flooring',#2839,$,$); -#2842=IFCCLASSIFICATIONREFERENCE($,'23-15 17 29 13 11','Elastomeric Liquid Flooring',#2841,$,$); -#2843=IFCCLASSIFICATIONREFERENCE($,'23-15 17 29 13 13','Epoxy Marble Chip Flooring',#2841,$,$); -#2844=IFCCLASSIFICATIONREFERENCE($,'23-15 17 29 13 15','Magnesium Oxychoride Flooring',#2841,$,$); -#2845=IFCCLASSIFICATIONREFERENCE($,'23-15 17 29 13 17','Mastic Fills Flooring',#2841,$,$); -#2846=IFCCLASSIFICATIONREFERENCE($,'23-15 17 29 13 19','Resinous Flooring',#2841,$,$); -#2847=IFCCLASSIFICATIONREFERENCE($,'23-15 17 29 13 21','Seamless Quartz Flooring',#2841,$,$); -#2848=IFCCLASSIFICATIONREFERENCE($,'23-15 19 00','Ceiling Coverings, Claddings, and Linings',#2610,$,$); -#2849=IFCCLASSIFICATIONREFERENCE($,'23-15 19 11','Ceiling Baffles',#2848,$,$); -#2850=IFCCLASSIFICATIONREFERENCE($,'23-15 19 13','Ceiling Clouds',#2848,$,$); -#2851=IFCCLASSIFICATIONREFERENCE($,'23-15 19 15','Ceiling Tiles, Panels, Strips, and Sections',#2848,$,$); -#2852=IFCCLASSIFICATIONREFERENCE($,'23-15 19 15 11','Ceiling Tiles',#2851,$,$); -#2853=IFCCLASSIFICATIONREFERENCE($,'23-15 19 15 11 11','Acoustical Ceiling Tile',#2852,$,$); -#2854=IFCCLASSIFICATIONREFERENCE($,'23-15 19 15 13','Ceiling Panels',#2851,$,$); -#2855=IFCCLASSIFICATIONREFERENCE($,'23-15 19 15 13 11','Acoustical Ceiling Panels',#2854,$,$); -#2856=IFCCLASSIFICATIONREFERENCE($,'23-15 19 15 13 13','Mirror Ceiling Panels',#2854,$,$); -#2857=IFCCLASSIFICATIONREFERENCE($,'23-15 19 15 13 15','Curved Ceiling Panels',#2854,$,$); -#2858=IFCCLASSIFICATIONREFERENCE($,'23-15 19 15 13 17','Metal Ceiling Panels',#2854,$,$); -#2859=IFCCLASSIFICATIONREFERENCE($,'23-15 19 15 15','Ceiling Covering Strips',#2851,$,$); -#2860=IFCCLASSIFICATIONREFERENCE($,'23-15 19 15 15 11','Linear Metal Ceiling Covering Strips',#2859,$,$); -#2861=IFCCLASSIFICATIONREFERENCE($,'23-15 19 15 15 13','Linear Wood Ceiling Covering Strips',#2859,$,$); -#2862=IFCCLASSIFICATIONREFERENCE($,'23-15 19 15 17','Ceiling Covering Sections',#2851,$,$); -#2863=IFCCLASSIFICATIONREFERENCE($,'23-15 19 15 17 11','Suspended Decorative Ceiling Grids',#2862,$,$); -#2864=IFCCLASSIFICATIONREFERENCE($,'23-15 19 17','Ceiling Finishing Coatings',#2848,$,$); -#2865=IFCCLASSIFICATIONREFERENCE($,'23-15 19 17 11','Textured Ceilings',#2864,$,$); -#2866=IFCCLASSIFICATIONREFERENCE($,'23-15 19 17 11 11','Gypsum Panel Textured Ceilings',#2865,$,$); -#2867=IFCCLASSIFICATIONREFERENCE($,'23-15 19 17 11 13','Metal Panel Textured Ceilings',#2865,$,$); -#2868=IFCCLASSIFICATIONREFERENCE($,'23-15 19 19','Ceiling Specialties and Accessories',#2848,$,$); -#2869=IFCCLASSIFICATIONREFERENCE($,'23-15 19 19 11','Roses Ceiling Centerpieces',#2868,$,$); -#2870=IFCCLASSIFICATIONREFERENCE($,'23-15 19 19 13','Ceiling Coving',#2868,$,$); -#2871=IFCCLASSIFICATIONREFERENCE($,'23-15 19 19 15','Ceiling Cornices',#2868,$,$); -#2872=IFCCLASSIFICATIONREFERENCE($,'23-15 19 19 17','Ceiling Friezes',#2868,$,$); -#2873=IFCCLASSIFICATIONREFERENCE($,'23-15 19 19 19','Integral Speaking Panels',#2868,$,$); -#2874=IFCCLASSIFICATIONREFERENCE($,'23-15 19 21','Ceiling Assembly Restoration Products',#2848,$,$); -#2875=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23','Ceilings',#2848,$,$); -#2876=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11','Suspended Ceilings',#2875,$,$); -#2877=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 11','Suspended Ceiling Components',#2876,$,$); -#2878=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 11 11','Suspended Ceilings, Suspension Assembly',#2877,$,$); -#2879=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 11 13','Suspended Ceilings, Panels and Tiles',#2877,$,$); -#2880=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 11 15','Suspended Ceilings, Grids',#2877,$,$); -#2881=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 11 17','Mechanical Fasteners for Suspended Ceilings',#2877,$,$); -#2882=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 13','Acoustical Ceilings',#2876,$,$); -#2883=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 13 11','Metal Pan Acoustical Ceilings',#2882,$,$); -#2884=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 13 13','Acoustical Panel Ceilings',#2882,$,$); -#2885=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 13 15','Acoustical Tile Ceilings',#2882,$,$); -#2886=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 15','Specialty Ceilings',#2876,$,$); -#2887=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 15 11','Integrated Ceilings',#2886,$,$); -#2888=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 15 13','Linear Ceilings',#2886,$,$); -#2889=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 15 13 11','Metal Linear Ceilings',#2888,$,$); -#2890=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 15 13 13','Wood Linear Ceilings',#2888,$,$); -#2891=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 15 15','Luminous Ceilings',#2886,$,$); -#2892=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 15 17','Mirror Panel Ceilings',#2886,$,$); -#2893=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 15 19','Textured Ceilings',#2886,$,$); -#2894=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 15 21','Suspended Decorative Grids',#2886,$,$); -#2895=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 15 23','Clean Room Ceilings',#2886,$,$); -#2896=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 13','Stretched Fabric Ceilings',#2875,$,$); -#2897=IFCCLASSIFICATIONREFERENCE($,'23-15 21 00','Surface Applied Coatings',#2610,$,$); -#2898=IFCCLASSIFICATIONREFERENCE($,'23-15 21 11','Paints and Varnishes',#2897,$,$); -#2899=IFCCLASSIFICATIONREFERENCE($,'23-15 21 11 11','General Purpose Paints and Varnishes',#2898,$,$); -#2900=IFCCLASSIFICATIONREFERENCE($,'23-15 21 11 11 11','Solvent Based General Purpose Paints and Varnishes',#2899,$,$); -#2901=IFCCLASSIFICATIONREFERENCE($,'23-15 21 11 11 13','Water Based General Purpose Paints and Varnishes',#2899,$,$); -#2902=IFCCLASSIFICATIONREFERENCE($,'23-15 21 11 13','Textured Paints',#2898,$,$); -#2903=IFCCLASSIFICATIONREFERENCE($,'23-15 21 11 13 11','Solvent Based Textured Paints',#2902,$,$); -#2904=IFCCLASSIFICATIONREFERENCE($,'23-15 21 11 13 13','Water Based Textured Paints',#2902,$,$); -#2905=IFCCLASSIFICATIONREFERENCE($,'23-15 21 13','Paints for Particular Applications',#2897,$,$); -#2906=IFCCLASSIFICATIONREFERENCE($,'23-15 21 13 11','Corrosion Prevention Paints',#2905,$,$); -#2907=IFCCLASSIFICATIONREFERENCE($,'23-15 21 13 13','Solar Reflective Paints',#2905,$,$); -#2908=IFCCLASSIFICATIONREFERENCE($,'23-15 21 13 15','Fluorescent Paints',#2905,$,$); -#2909=IFCCLASSIFICATIONREFERENCE($,'23-15 21 13 17','Line Paints',#2905,$,$); -#2910=IFCCLASSIFICATIONREFERENCE($,'23-15 21 13 19','Roadway Marking Paints',#2905,$,$); -#2911=IFCCLASSIFICATIONREFERENCE($,'23-15 21 13 21','Swimming Pool Paints',#2905,$,$); -#2912=IFCCLASSIFICATIONREFERENCE($,'23-15 21 13 23','Coatings for Concrete and Masonry',#2905,$,$); -#2913=IFCCLASSIFICATIONREFERENCE($,'23-15 21 13 25','Mold/Mildew Resistant Coatings',#2905,$,$); -#2914=IFCCLASSIFICATIONREFERENCE($,'23-15 21 15','Powder Coating Services',#2897,$,$); -#2915=IFCCLASSIFICATIONREFERENCE($,'23-15 21 15 11','Factory Applied Metal Powder Coatings',#2914,$,$); -#2916=IFCCLASSIFICATIONREFERENCE($,'23-15 21 17','Inorganic Metal Treatments',#2897,$,$); -#2917=IFCCLASSIFICATIONREFERENCE($,'23-15 21 17 11','Galvanized Coatings',#2916,$,$); -#2918=IFCCLASSIFICATIONREFERENCE($,'23-15 21 17 13','Anodized Coatings',#2916,$,$); -#2919=IFCCLASSIFICATIONREFERENCE($,'23-15 21 17 15','Electro Plated Coatings',#2916,$,$); -#2920=IFCCLASSIFICATIONREFERENCE($,'23-15 21 17 17','Vitreous Enameling',#2916,$,$); -#2921=IFCCLASSIFICATIONREFERENCE($,'23-15 21 19','Stains and Decorative Surface Impregnations',#2897,$,$); -#2922=IFCCLASSIFICATIONREFERENCE($,'23-15 21 19 11','Decorative Wood Conservation Products',#2921,$,$); -#2923=IFCCLASSIFICATIONREFERENCE($,'23-15 21 19 13','Stains',#2921,$,$); -#2924=IFCCLASSIFICATIONREFERENCE($,'23-15 21 19 13 11','Opaque Stains',#2923,$,$); -#2925=IFCCLASSIFICATIONREFERENCE($,'23-15 21 19 13 11 11','Exterior Opaque Stains',#2924,$,$); -#2926=IFCCLASSIFICATIONREFERENCE($,'23-15 21 19 13 11 13','Interior Opaque Stains',#2924,$,$); -#2927=IFCCLASSIFICATIONREFERENCE($,'23-15 21 19 13 13','Transparent Stains',#2923,$,$); -#2928=IFCCLASSIFICATIONREFERENCE($,'23-15 21 19 13 13 11','Exterior Transparent Stains',#2927,$,$); -#2929=IFCCLASSIFICATIONREFERENCE($,'23-15 21 19 13 13 13','Interior Transparent Stains',#2927,$,$); -#2930=IFCCLASSIFICATIONREFERENCE($,'23-15 21 21','High Performance Coatings',#2897,$,$); -#2931=IFCCLASSIFICATIONREFERENCE($,'23-15 21 21 11','Abrasion Resistant Coatings',#2930,$,$); -#2932=IFCCLASSIFICATIONREFERENCE($,'23-15 21 21 13','Chemical Resistant Coatings',#2930,$,$); -#2933=IFCCLASSIFICATIONREFERENCE($,'23-15 21 21 15','Elastomeric Coatings',#2930,$,$); -#2934=IFCCLASSIFICATIONREFERENCE($,'23-15 21 21 17','Fire Resistant Coatings',#2930,$,$); -#2935=IFCCLASSIFICATIONREFERENCE($,'23-15 21 21 19','Graffiti Resistant Coatings',#2930,$,$); -#2936=IFCCLASSIFICATIONREFERENCE($,'23-15 21 21 21','High Building Coatings',#2930,$,$); -#2937=IFCCLASSIFICATIONREFERENCE($,'23-15 21 21 23','Intumescent Paints',#2930,$,$); -#2938=IFCCLASSIFICATIONREFERENCE($,'23-15 21 21 25','Marine Coatings',#2930,$,$); -#2939=IFCCLASSIFICATIONREFERENCE($,'23-15 21 21 27','Textured Plastic Coatings',#2930,$,$); -#2940=IFCCLASSIFICATIONREFERENCE($,'23-15 21 23','Protective Surface Impregnations',#2897,$,$); -#2941=IFCCLASSIFICATIONREFERENCE($,'23-15 21 23 11','Surface Consolidation Hardening Impregnations',#2940,$,$); -#2942=IFCCLASSIFICATIONREFERENCE($,'23-15 21 23 13','Impregnations Protecting from Biological Attack',#2940,$,$); -#2943=IFCCLASSIFICATIONREFERENCE($,'23-15 21 23 13 11','Wood Treatment Protecting from Biological Attack',#2942,$,$); -#2944=IFCCLASSIFICATIONREFERENCE($,'23-15 21 23 15','Impregnations Protecting from Fire',#2940,$,$); -#2945=IFCCLASSIFICATIONREFERENCE($,'23-15 21 23 15 11','Wood Treatment Protecting from Fire',#2944,$,$); -#2946=IFCCLASSIFICATIONREFERENCE($,'23-15 21 23 15 11 11','Fire Retardant Treatment',#2945,$,$); -#2947=IFCCLASSIFICATIONREFERENCE($,'23-15 21 23 17','Water Repellents',#2940,$,$); -#2948=IFCCLASSIFICATIONREFERENCE($,'23-15 21 23 17 11','Acrylic Water Repellents',#2947,$,$); -#2949=IFCCLASSIFICATIONREFERENCE($,'23-15 21 23 17 13','Silane Water Repellents',#2947,$,$); -#2950=IFCCLASSIFICATIONREFERENCE($,'23-15 21 23 17 15','Silicone Water Repellents',#2947,$,$); -#2951=IFCCLASSIFICATIONREFERENCE($,'23-15 21 23 17 17','Siloxane Water Repellents',#2947,$,$); -#2952=IFCCLASSIFICATIONREFERENCE($,'23-15 21 23 17 19','Stearate Water Repellents',#2947,$,$); -#2953=IFCCLASSIFICATIONREFERENCE($,'23-17 00 00','Openings, Passages, and Protection Products',#1604,$,$); -#2954=IFCCLASSIFICATIONREFERENCE($,'23-17 11 00','Doors',#2953,$,$); -#2955=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11','Door Components',#2954,$,$); -#2956=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 11','Door Frames',#2955,$,$); -#2957=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 13','Preassembled Door and Frame Units',#2955,$,$); -#2958=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 15','Door Fanlights',#2955,$,$); -#2959=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 17','Door Sections',#2955,$,$); -#2960=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 17 11','Structural Door Sections',#2959,$,$); -#2961=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 17 13','Door Cladding Sections',#2959,$,$); -#2962=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 19','Door Linings and Boards',#2955,$,$); -#2963=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 21','Door Renovation Sets',#2955,$,$); -#2964=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 23','Door Sidelites',#2955,$,$); -#2965=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 25','Door Accessories',#2955,$,$); -#2966=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 25 11','Door Peep Holes',#2965,$,$); -#2967=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 25 13','Door Buffers',#2965,$,$); -#2968=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 25 15','Door Stops',#2965,$,$); -#2969=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 25 17','Door Mail Openings',#2965,$,$); -#2970=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 25 19','Door Mail Slots',#2965,$,$); -#2971=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 25 21','Door Louvers',#2965,$,$); -#2972=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 25 23','Door Lights',#2965,$,$); -#2973=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13','Metal Doors',#2954,$,$); -#2974=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 11','Hollow Metal Doors',#2973,$,$); -#2975=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 13','Aluminum Doors',#2973,$,$); -#2976=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 13 11','Aluminum Screen Doors',#2975,$,$); -#2977=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 13 13','Aluminum Storm Doors',#2975,$,$); -#2978=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 15','Steel Doors',#2973,$,$); -#2979=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 15 11','Steel Screen Doors',#2978,$,$); -#2980=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 15 13','Steel Storm Doors',#2978,$,$); -#2981=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 17','Bronze Doors',#2973,$,$); -#2982=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 19','Sliding Metal Doors',#2973,$,$); -#2983=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 21','Folding Metal Doors',#2973,$,$); -#2984=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 23','Revolving Metal Doors',#2973,$,$); -#2985=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 25','Overhead Metal Doors',#2973,$,$); -#2986=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 25 11','Roller Shutter Overhead Metal Doors',#2985,$,$); -#2987=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 25 13','Sectional Overhead Metal Doors',#2985,$,$); -#2988=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15','Wood Doors',#2954,$,$); -#2989=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15 11','Carved Wood Doors',#2988,$,$); -#2990=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15 13','Flush Wood Doors',#2988,$,$); -#2991=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15 15','Clad Wood Doors',#2988,$,$); -#2992=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15 17','Prefinished Wood Doors',#2988,$,$); -#2993=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15 19','Stile and Rail Wood Doors',#2988,$,$); -#2994=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15 21','Wood Storm Doors',#2988,$,$); -#2995=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15 23','Wood Screen Doors',#2988,$,$); -#2996=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15 25','Sliding Wood Doors',#2988,$,$); -#2997=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15 27','Folding Wood Doors',#2988,$,$); -#2998=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15 29','Revolving Wood Doors',#2988,$,$); -#2999=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15 31','Overhead Wood Doors',#2988,$,$); -#3000=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15 31 11','Roller Shutter Overhead Wood Doors',#2999,$,$); -#3001=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15 31 13','Sectional Overhead Wood Doors',#2999,$,$); -#3002=IFCCLASSIFICATIONREFERENCE($,'23-17 11 17','Plastic Doors',#2954,$,$); -#3003=IFCCLASSIFICATIONREFERENCE($,'23-17 11 17 11','Laminated Plastic Doors',#3002,$,$); -#3004=IFCCLASSIFICATIONREFERENCE($,'23-17 11 17 13','Solid Plastic Doors',#3002,$,$); -#3005=IFCCLASSIFICATIONREFERENCE($,'23-17 11 17 15','Plastic Storm Doors',#3002,$,$); -#3006=IFCCLASSIFICATIONREFERENCE($,'23-17 11 17 17','Plastic Screen Doors',#3002,$,$); -#3007=IFCCLASSIFICATIONREFERENCE($,'23-17 11 17 19','Sliding Plastic Doors',#3002,$,$); -#3008=IFCCLASSIFICATIONREFERENCE($,'23-17 11 17 21','Folding Plastic Doors',#3002,$,$); -#3009=IFCCLASSIFICATIONREFERENCE($,'23-17 11 17 23','Revolving Plastic Doors',#3002,$,$); -#3010=IFCCLASSIFICATIONREFERENCE($,'23-17 11 17 25','Overhead Plastic Doors',#3002,$,$); -#3011=IFCCLASSIFICATIONREFERENCE($,'23-17 11 17 25 11','Roller Shutter Overhead Plastic Doors',#3010,$,$); -#3012=IFCCLASSIFICATIONREFERENCE($,'23-17 11 17 25 13','Sectional Overhead Plastic Doors',#3010,$,$); -#3013=IFCCLASSIFICATIONREFERENCE($,'23-17 11 19','Composite Doors',#2954,$,$); -#3014=IFCCLASSIFICATIONREFERENCE($,'23-17 11 19 11','Fiberglass Composite Doors',#3013,$,$); -#3015=IFCCLASSIFICATIONREFERENCE($,'23-17 11 19 13','Sliding Composite Doors',#3013,$,$); -#3016=IFCCLASSIFICATIONREFERENCE($,'23-17 11 19 15','Folding Composite Doors',#3013,$,$); -#3017=IFCCLASSIFICATIONREFERENCE($,'23-17 11 19 17','Composite Hinged Doors',#3013,$,$); -#3018=IFCCLASSIFICATIONREFERENCE($,'23-17 11 19 19','Revolving Composite Doors',#3013,$,$); -#3019=IFCCLASSIFICATIONREFERENCE($,'23-17 11 19 21','Overhead Composite Doors',#3013,$,$); -#3020=IFCCLASSIFICATIONREFERENCE($,'23-17 11 19 21 11','Roller Shutter Overhead Composite Doors',#3019,$,$); -#3021=IFCCLASSIFICATIONREFERENCE($,'23-17 11 19 21 13','Sectional Overhead Composite Doors',#3019,$,$); -#3022=IFCCLASSIFICATIONREFERENCE($,'23-17 11 21','Glazed Doors',#2954,$,$); -#3023=IFCCLASSIFICATIONREFERENCE($,'23-17 11 21 11','Glazed Hinged Doors',#3022,$,$); -#3024=IFCCLASSIFICATIONREFERENCE($,'23-17 11 23','All Glass Doors',#2954,$,$); -#3025=IFCCLASSIFICATIONREFERENCE($,'23-17 11 23 11','Swinging All Glass Doors',#3024,$,$); -#3026=IFCCLASSIFICATIONREFERENCE($,'23-17 11 23 13','Sliding All Glass Doors',#3024,$,$); -#3027=IFCCLASSIFICATIONREFERENCE($,'23-17 11 23 15','Folding All Glass Doors and Grilles',#3024,$,$); -#3028=IFCCLASSIFICATIONREFERENCE($,'23-17 11 23 15 11','Accordion Folding All Glass Doors',#3027,$,$); -#3029=IFCCLASSIFICATIONREFERENCE($,'23-17 11 23 15 13','Panel Folding All Glass Doors',#3027,$,$); -#3030=IFCCLASSIFICATIONREFERENCE($,'23-17 11 23 15 15','Bifold All Glass Doors',#3027,$,$); -#3031=IFCCLASSIFICATIONREFERENCE($,'23-17 11 23 17','Revolving All Glass Doors',#3024,$,$); -#3032=IFCCLASSIFICATIONREFERENCE($,'23-17 11 23 19','Balanced All Glass Doors',#3024,$,$); -#3033=IFCCLASSIFICATIONREFERENCE($,'23-17 11 25','Passage Grilles',#2954,$,$); -#3034=IFCCLASSIFICATIONREFERENCE($,'23-17 11 25 11','Sliding Passage Grilles',#3033,$,$); -#3035=IFCCLASSIFICATIONREFERENCE($,'23-17 11 25 13','Folding Passage Grilles',#3033,$,$); -#3036=IFCCLASSIFICATIONREFERENCE($,'23-17 11 25 13 11','Accordion Folding Passage Grilles',#3035,$,$); -#3037=IFCCLASSIFICATIONREFERENCE($,'23-17 11 25 15','Rolling Grilles',#3033,$,$); -#3038=IFCCLASSIFICATIONREFERENCE($,'23-17 11 27','Access Doors',#2954,$,$); -#3039=IFCCLASSIFICATIONREFERENCE($,'23-17 11 27 11','Trap Doors',#3038,$,$); -#3040=IFCCLASSIFICATIONREFERENCE($,'23-17 11 27 13','Access Doors',#3038,$,$); -#3041=IFCCLASSIFICATIONREFERENCE($,'23-17 11 27 15','Floor Hatches',#3038,$,$); -#3042=IFCCLASSIFICATIONREFERENCE($,'23-17 11 27 17','Roof Hatches',#3038,$,$); -#3043=IFCCLASSIFICATIONREFERENCE($,'23-17 11 27 19','Security Floor Hatches',#3038,$,$); -#3044=IFCCLASSIFICATIONREFERENCE($,'23-17 11 27 21','Security Roof Hatches',#3038,$,$); -#3045=IFCCLASSIFICATIONREFERENCE($,'23-17 11 27 21 11','Forced Entry and Ballistic Resistant Roof Hatches',#3044,$,$); -#3046=IFCCLASSIFICATIONREFERENCE($,'23-17 11 27 21 13','Ballistic Resistant Roof Hatches',#3044,$,$); -#3047=IFCCLASSIFICATIONREFERENCE($,'23-17 11 27 23','Man Hole Accesses',#3038,$,$); -#3048=IFCCLASSIFICATIONREFERENCE($,'23-17 11 29','Access Panels',#2954,$,$); -#3049=IFCCLASSIFICATIONREFERENCE($,'23-17 11 29 11','Equipment Access Panels',#3048,$,$); -#3050=IFCCLASSIFICATIONREFERENCE($,'23-17 11 31','Fire Doors',#2954,$,$); -#3051=IFCCLASSIFICATIONREFERENCE($,'23-17 11 31 11','Fire Rated Doors',#3050,$,$); -#3052=IFCCLASSIFICATIONREFERENCE($,'23-17 11 31 11 11','Fire Rated Overhead Doors',#3051,$,$); -#3053=IFCCLASSIFICATIONREFERENCE($,'23-17 11 31 11 13','Fire Rated Rolling Doors',#3051,$,$); -#3054=IFCCLASSIFICATIONREFERENCE($,'23-17 11 31 11 15','Fire Rated Sliding Doors',#3051,$,$); -#3055=IFCCLASSIFICATIONREFERENCE($,'23-17 11 31 11 17','Fire Rated Hinged Doors',#3051,$,$); -#3056=IFCCLASSIFICATIONREFERENCE($,'23-17 11 31 11 19','Fire Rated Revolving Doors',#3051,$,$); -#3057=IFCCLASSIFICATIONREFERENCE($,'23-17 11 31 13','Temperature Rate of Rise Fire Doors',#3050,$,$); -#3058=IFCCLASSIFICATIONREFERENCE($,'23-17 11 31 13 11','Temperature Rate of Rise Fire Rated Overhead Doors',#3057,$,$); -#3059=IFCCLASSIFICATIONREFERENCE($,'23-17 11 31 13 13','Temperature Rate of Rise Fire Rated Rolling Doors',#3057,$,$); -#3060=IFCCLASSIFICATIONREFERENCE($,'23-17 11 31 13 15','Temperature Rate of Rise Fire Rated Sliding Doors',#3057,$,$); -#3061=IFCCLASSIFICATIONREFERENCE($,'23-17 11 31 13 17','Temperature Rate of Rise Fire Rated Hinged Doors',#3057,$,$); -#3062=IFCCLASSIFICATIONREFERENCE($,'23-17 11 31 13 19','Temperature Rate of Rise Fire Rated Revolving Doors',#3057,$,$); -#3063=IFCCLASSIFICATIONREFERENCE($,'23-17 11 35','Fire Shutters',#2954,$,$); -#3064=IFCCLASSIFICATIONREFERENCE($,'23-17 11 37','Controlled Environment Doors',#2954,$,$); -#3065=IFCCLASSIFICATIONREFERENCE($,'23-17 11 37 11','Cold Storage Doors',#3064,$,$); -#3066=IFCCLASSIFICATIONREFERENCE($,'23-17 11 37 13','Sound Control Doors',#3064,$,$); -#3067=IFCCLASSIFICATIONREFERENCE($,'23-17 11 37 15','Radiation Protection Doors',#3064,$,$); -#3068=IFCCLASSIFICATIONREFERENCE($,'23-17 11 37 15 11','Electromagnetic Shielding Doors',#3067,$,$); -#3069=IFCCLASSIFICATIONREFERENCE($,'23-17 11 37 15 13','Radio Frequency Protection Doors',#3067,$,$); -#3070=IFCCLASSIFICATIONREFERENCE($,'23-17 11 37 15 15','BO Shielding Doors',#3067,$,$); -#3071=IFCCLASSIFICATIONREFERENCE($,'23-17 11 37 15 17','X Ray Protection Doors',#3067,$,$); -#3072=IFCCLASSIFICATIONREFERENCE($,'23-17 11 37 15 19','Nuclear Radiation Protection Doors',#3067,$,$); -#3073=IFCCLASSIFICATIONREFERENCE($,'23-17 11 37 15 21','High Energy Magnetic Pulse Protection Doors',#3067,$,$); -#3074=IFCCLASSIFICATIONREFERENCE($,'23-17 11 39','Detention Doors',#2954,$,$); -#3075=IFCCLASSIFICATIONREFERENCE($,'23-17 11 41','Hanger Doors',#2954,$,$); -#3076=IFCCLASSIFICATIONREFERENCE($,'23-17 11 43','Lightproof Doors',#2954,$,$); -#3077=IFCCLASSIFICATIONREFERENCE($,'23-17 11 43 11','Revolving Darkroom Door',#3076,$,$); -#3078=IFCCLASSIFICATIONREFERENCE($,'23-17 11 45','Traffic Doors',#2954,$,$); -#3079=IFCCLASSIFICATIONREFERENCE($,'23-17 11 45 11','Flexible Traffic Doors',#3078,$,$); -#3080=IFCCLASSIFICATIONREFERENCE($,'23-17 11 45 13','Flexible Strip Doors',#3078,$,$); -#3081=IFCCLASSIFICATIONREFERENCE($,'23-17 11 45 15','Rigid Panel Traffic Doors',#3078,$,$); -#3082=IFCCLASSIFICATIONREFERENCE($,'23-17 11 45 17','Rapid Opening Doors',#3078,$,$); -#3083=IFCCLASSIFICATIONREFERENCE($,'23-17 11 47','Pressure Resistant Doors',#2954,$,$); -#3084=IFCCLASSIFICATIONREFERENCE($,'23-17 11 47 11','Airtight Doors',#3083,$,$); -#3085=IFCCLASSIFICATIONREFERENCE($,'23-17 11 47 13','Watertight Doors',#3083,$,$); -#3086=IFCCLASSIFICATIONREFERENCE($,'23-17 11 49','Security Rated Door',#2954,$,$); -#3087=IFCCLASSIFICATIONREFERENCE($,'23-17 11 49 11','Blast Resistant Doors',#3086,$,$); -#3088=IFCCLASSIFICATIONREFERENCE($,'23-17 11 49 13','Forced Entry Door',#3086,$,$); -#3089=IFCCLASSIFICATIONREFERENCE($,'23-17 11 49 13 11','Multi Forced Entry Lock Door',#3088,$,$); -#3090=IFCCLASSIFICATIONREFERENCE($,'23-17 11 49 13 13','Single Forced Entry Lock Door',#3088,$,$); -#3091=IFCCLASSIFICATIONREFERENCE($,'23-17 11 49 15','Forced Entry and Ballistic Resistant Door',#3086,$,$); -#3092=IFCCLASSIFICATIONREFERENCE($,'23-17 11 49 17','Ballistic Resistant Door',#3086,$,$); -#3093=IFCCLASSIFICATIONREFERENCE($,'23-17 13 00','Windows',#2953,$,$); -#3094=IFCCLASSIFICATIONREFERENCE($,'23-17 13 11','Window Components',#3093,$,$); -#3095=IFCCLASSIFICATIONREFERENCE($,'23-17 13 11 11','Window Sections',#3094,$,$); -#3096=IFCCLASSIFICATIONREFERENCE($,'23-17 13 11 13','Window Linings and Boards',#3094,$,$); -#3097=IFCCLASSIFICATIONREFERENCE($,'23-17 13 11 15','Window Vents',#3094,$,$); -#3098=IFCCLASSIFICATIONREFERENCE($,'23-17 13 11 17','Window Frames',#3094,$,$); -#3099=IFCCLASSIFICATIONREFERENCE($,'23-17 13 11 19','Transoms',#3094,$,$); -#3100=IFCCLASSIFICATIONREFERENCE($,'23-17 13 11 21','Sidelites',#3094,$,$); -#3101=IFCCLASSIFICATIONREFERENCE($,'23-17 13 11 23','Retractable Screens',#3094,$,$); -#3102=IFCCLASSIFICATIONREFERENCE($,'23-17 13 13','Metal Windows',#3093,$,$); -#3103=IFCCLASSIFICATIONREFERENCE($,'23-17 13 13 11','Metal Fixed Windows',#3102,$,$); -#3104=IFCCLASSIFICATIONREFERENCE($,'23-17 13 13 13','Metal Horizontal Sliding Windows',#3102,$,$); -#3105=IFCCLASSIFICATIONREFERENCE($,'23-17 13 13 15','Metal Single Hung Windows',#3102,$,$); -#3106=IFCCLASSIFICATIONREFERENCE($,'23-17 13 13 17','Metal Double Hung Windows',#3102,$,$); -#3107=IFCCLASSIFICATIONREFERENCE($,'23-17 13 13 19','Metal Triple Hung Windows',#3102,$,$); -#3108=IFCCLASSIFICATIONREFERENCE($,'23-17 13 13 21','Metal Awning Windows',#3102,$,$); -#3109=IFCCLASSIFICATIONREFERENCE($,'23-17 13 13 23','Metal Casement Windows',#3102,$,$); -#3110=IFCCLASSIFICATIONREFERENCE($,'23-17 13 13 25','Metal Hopper Windows',#3102,$,$); -#3111=IFCCLASSIFICATIONREFERENCE($,'23-17 13 13 27','Metal Vertical Pivoted Windows',#3102,$,$); -#3112=IFCCLASSIFICATIONREFERENCE($,'23-17 13 13 29','Metal Jalousie Windows',#3102,$,$); -#3113=IFCCLASSIFICATIONREFERENCE($,'23-17 13 15','Wood Windows',#3093,$,$); -#3114=IFCCLASSIFICATIONREFERENCE($,'23-17 13 15 11','Wood Fixed Windows',#3113,$,$); -#3115=IFCCLASSIFICATIONREFERENCE($,'23-17 13 15 13','Wood Horizontal Sliding Windows',#3113,$,$); -#3116=IFCCLASSIFICATIONREFERENCE($,'23-17 13 15 15','Wood Single Hung Windows',#3113,$,$); -#3117=IFCCLASSIFICATIONREFERENCE($,'23-17 13 15 17','Wood Double Hung Windows',#3113,$,$); -#3118=IFCCLASSIFICATIONREFERENCE($,'23-17 13 15 19','Wood Triple Hung Windows',#3113,$,$); -#3119=IFCCLASSIFICATIONREFERENCE($,'23-17 13 15 21','Wood Awning Windows',#3113,$,$); -#3120=IFCCLASSIFICATIONREFERENCE($,'23-17 13 15 23','Wood Casement Windows',#3113,$,$); -#3121=IFCCLASSIFICATIONREFERENCE($,'23-17 13 15 25','Wood Hopper Windows',#3113,$,$); -#3122=IFCCLASSIFICATIONREFERENCE($,'23-17 13 15 27','Wood Vertical Pivoted Windows',#3113,$,$); -#3123=IFCCLASSIFICATIONREFERENCE($,'23-17 13 15 29','Wood Jalousie Windows',#3113,$,$); -#3124=IFCCLASSIFICATIONREFERENCE($,'23-17 13 17','Plastic Windows',#3093,$,$); -#3125=IFCCLASSIFICATIONREFERENCE($,'23-17 13 17 11','Plastic Fixed Windows',#3124,$,$); -#3126=IFCCLASSIFICATIONREFERENCE($,'23-17 13 17 13','Plastic Horizontal Sliding Windows',#3124,$,$); -#3127=IFCCLASSIFICATIONREFERENCE($,'23-17 13 17 15','Plastic Single Hung Windows',#3124,$,$); -#3128=IFCCLASSIFICATIONREFERENCE($,'23-17 13 17 17','Plastic Double Hung Windows',#3124,$,$); -#3129=IFCCLASSIFICATIONREFERENCE($,'23-17 13 17 19','Plastic Triple Hung Windows',#3124,$,$); -#3130=IFCCLASSIFICATIONREFERENCE($,'23-17 13 17 21','Plastic Awning Windows',#3124,$,$); -#3131=IFCCLASSIFICATIONREFERENCE($,'23-17 13 17 23','Plastic Casement Windows',#3124,$,$); -#3132=IFCCLASSIFICATIONREFERENCE($,'23-17 13 17 25','Plastic Hopper Windows',#3124,$,$); -#3133=IFCCLASSIFICATIONREFERENCE($,'23-17 13 17 27','Plastic Vertical Pivoted Windows',#3124,$,$); -#3134=IFCCLASSIFICATIONREFERENCE($,'23-17 13 17 29','Plastic Jalousie Windows',#3124,$,$); -#3135=IFCCLASSIFICATIONREFERENCE($,'23-17 13 17 31','Plastic Jalousie Awning Windows',#3124,$,$); -#3136=IFCCLASSIFICATIONREFERENCE($,'23-17 13 19','Composite Windows',#3093,$,$); -#3137=IFCCLASSIFICATIONREFERENCE($,'23-17 13 19 11','Composite Fixed Windows',#3136,$,$); -#3138=IFCCLASSIFICATIONREFERENCE($,'23-17 13 19 13','Composite Horizontal Sliding Windows',#3136,$,$); -#3139=IFCCLASSIFICATIONREFERENCE($,'23-17 13 19 15','Composite Single Hung Windows',#3136,$,$); -#3140=IFCCLASSIFICATIONREFERENCE($,'23-17 13 19 17','Composite Double Hung Windows',#3136,$,$); -#3141=IFCCLASSIFICATIONREFERENCE($,'23-17 13 19 19','Composite Triple Hung Windows',#3136,$,$); -#3142=IFCCLASSIFICATIONREFERENCE($,'23-17 13 19 21','Composite Awning Windows',#3136,$,$); -#3143=IFCCLASSIFICATIONREFERENCE($,'23-17 13 19 23','Composite Casement Windows',#3136,$,$); -#3144=IFCCLASSIFICATIONREFERENCE($,'23-17 13 19 25','Composite Hopper Windows',#3136,$,$); -#3145=IFCCLASSIFICATIONREFERENCE($,'23-17 13 19 27','Composite Vertical Pivoted Windows',#3136,$,$); -#3146=IFCCLASSIFICATIONREFERENCE($,'23-17 13 19 29','Composite Jalousie Windows',#3136,$,$); -#3147=IFCCLASSIFICATIONREFERENCE($,'23-17 13 19 31','Composite Jalousie Awning Windows',#3136,$,$); -#3148=IFCCLASSIFICATIONREFERENCE($,'23-17 13 21','Projecting Windows',#3093,$,$); -#3149=IFCCLASSIFICATIONREFERENCE($,'23-17 13 21 11','Bay Windows',#3148,$,$); -#3150=IFCCLASSIFICATIONREFERENCE($,'23-17 13 21 11 11','Angles Bay Windows',#3149,$,$); -#3151=IFCCLASSIFICATIONREFERENCE($,'23-17 13 21 11 13','Box Bay Windows',#3149,$,$); -#3152=IFCCLASSIFICATIONREFERENCE($,'23-17 13 21 13','Bow Windows',#3148,$,$); -#3153=IFCCLASSIFICATIONREFERENCE($,'23-17 13 23','Roof Windows',#3093,$,$); -#3154=IFCCLASSIFICATIONREFERENCE($,'23-17 13 25','Masonry Windows',#3093,$,$); -#3155=IFCCLASSIFICATIONREFERENCE($,'23-17 13 25 11','Glass Masonry Unit Windows',#3154,$,$); -#3156=IFCCLASSIFICATIONREFERENCE($,'23-17 13 27','Special Purpose Windows',#3093,$,$); -#3157=IFCCLASSIFICATIONREFERENCE($,'23-17 13 27 11','Fire Rated Windows',#3156,$,$); -#3158=IFCCLASSIFICATIONREFERENCE($,'23-17 13 27 13','Detention Windows',#3156,$,$); -#3159=IFCCLASSIFICATIONREFERENCE($,'23-17 13 27 15','Pass Windows',#3156,$,$); -#3160=IFCCLASSIFICATIONREFERENCE($,'23-17 13 27 17','Controlled Environment Windows',#3156,$,$); -#3161=IFCCLASSIFICATIONREFERENCE($,'23-17 13 27 17 11','Sound Control Windows',#3160,$,$); -#3162=IFCCLASSIFICATIONREFERENCE($,'23-17 13 27 17 13','Radiation Protection Windows',#3160,$,$); -#3163=IFCCLASSIFICATIONREFERENCE($,'23-17 13 27 17 13 11','Electromagnetic Shielding Windows',#3162,$,$); -#3164=IFCCLASSIFICATIONREFERENCE($,'23-17 13 27 17 13 13','BO Shielding Windows',#3162,$,$); -#3165=IFCCLASSIFICATIONREFERENCE($,'23-17 13 27 17 13 15','Radio Frequency Protection Windows',#3162,$,$); -#3166=IFCCLASSIFICATIONREFERENCE($,'23-17 13 27 17 13 17','X Ray Protection Windows',#3162,$,$); -#3167=IFCCLASSIFICATIONREFERENCE($,'23-17 13 27 17 13 19','Nuclear Radiation Protection Windows',#3162,$,$); -#3168=IFCCLASSIFICATIONREFERENCE($,'23-17 13 27 17 13 21','High Energy Magnetic Pulse Protection Windows',#3162,$,$); -#3169=IFCCLASSIFICATIONREFERENCE($,'23-17 13 29','Security Windows',#3093,$,$); -#3170=IFCCLASSIFICATIONREFERENCE($,'23-17 13 29 11','Ballistic Resistant Windows',#3169,$,$); -#3171=IFCCLASSIFICATIONREFERENCE($,'23-17 13 29 11 11','Teller Forced Entry and Ballistic Resistant Windows',#3170,$,$); -#3172=IFCCLASSIFICATIONREFERENCE($,'23-17 13 29 13','Blast Resistant Windows',#3169,$,$); -#3173=IFCCLASSIFICATIONREFERENCE($,'23-17 13 29 13 11','Blast Resistant Structural Muntin Windows',#3172,$,$); -#3174=IFCCLASSIFICATIONREFERENCE($,'23-17 13 29 13 13','Blast Resistant Window Frames',#3172,$,$); -#3175=IFCCLASSIFICATIONREFERENCE($,'23-17 13 29 15','Impact Resistant Windows',#3169,$,$); -#3176=IFCCLASSIFICATIONREFERENCE($,'23-17 13 29 17','Forced Entry Resistant Windows',#3169,$,$); -#3177=IFCCLASSIFICATIONREFERENCE($,'23-17 13 29 19','Radio Frequency Shielding Windows',#3169,$,$); -#3178=IFCCLASSIFICATIONREFERENCE($,'23-17 13 29 21','Security Window Films',#3169,$,$); -#3179=IFCCLASSIFICATIONREFERENCE($,'23-17 13 29 21 11','Shatter Resistant Security Window Films',#3178,$,$); -#3180=IFCCLASSIFICATIONREFERENCE($,'23-17 13 29 23','Security Window Curtains',#3169,$,$); -#3181=IFCCLASSIFICATIONREFERENCE($,'23-17 13 29 23 11','Security Window Blast Curtains',#3180,$,$); -#3182=IFCCLASSIFICATIONREFERENCE($,'23-17 15 00','Glazing',#2953,$,$); -#3183=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11','Glass Glazing',#3182,$,$); -#3184=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 11','Bent Glass',#3183,$,$); -#3185=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 13','Chemically Strengthened Glass',#3183,$,$); -#3186=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 15','Coated Glass',#3183,$,$); -#3187=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 17','Composite Glass',#3183,$,$); -#3188=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 19','Decorative Glass',#3183,$,$); -#3189=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 21','Fire Rated Glass',#3183,$,$); -#3190=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 23','Float Glass',#3183,$,$); -#3191=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 25','Heat Strengthened Glass',#3183,$,$); -#3192=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 27','Impact Resistant Glass',#3183,$,$); -#3193=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 29','Insulating Glass',#3183,$,$); -#3194=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 31','Laminated Glass',#3183,$,$); -#3195=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 33','Low Emissivity Glass',#3183,$,$); -#3196=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 35','Rolled Glass',#3183,$,$); -#3197=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 37','Spandrel Glass',#3183,$,$); -#3198=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 39','Tempered Glass',#3183,$,$); -#3199=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 41','Wired Glass',#3183,$,$); -#3200=IFCCLASSIFICATIONREFERENCE($,'23-17 15 13','Plastic Glazing',#3182,$,$); -#3201=IFCCLASSIFICATIONREFERENCE($,'23-17 15 13 11','Ballistics Resistant Plastic Glazing',#3200,$,$); -#3202=IFCCLASSIFICATIONREFERENCE($,'23-17 15 13 13','Decorative Plastic Glazing',#3200,$,$); -#3203=IFCCLASSIFICATIONREFERENCE($,'23-17 15 13 15','Insulating Plastic Glazing',#3200,$,$); -#3204=IFCCLASSIFICATIONREFERENCE($,'23-17 15 13 17','Translucent Plastic Glazing',#3200,$,$); -#3205=IFCCLASSIFICATIONREFERENCE($,'23-17 15 13 19','Transparent Plastic Glazing',#3200,$,$); -#3206=IFCCLASSIFICATIONREFERENCE($,'23-17 15 15','Security Glass',#3182,$,$); -#3207=IFCCLASSIFICATIONREFERENCE($,'23-17 15 15 11','Laminated Security Glass',#3206,$,$); -#3208=IFCCLASSIFICATIONREFERENCE($,'23-17 15 17','Tinted Glass',#3182,$,$); -#3209=IFCCLASSIFICATIONREFERENCE($,'23-17 15 19','Glazing by Special Function',#3182,$,$); -#3210=IFCCLASSIFICATIONREFERENCE($,'23-17 15 19 11','Security Glazing',#3209,$,$); -#3211=IFCCLASSIFICATIONREFERENCE($,'23-17 15 19 13','Ballistics Resistant Glass Glazing',#3209,$,$); -#3212=IFCCLASSIFICATIONREFERENCE($,'23-17 15 19 15','Pressure Resistant Glazing',#3209,$,$); -#3213=IFCCLASSIFICATIONREFERENCE($,'23-17 15 19 17','Hurricane Resistant Glazing',#3209,$,$); -#3214=IFCCLASSIFICATIONREFERENCE($,'23-17 15 19 19','Radiation Resistant Glazing',#3209,$,$); -#3215=IFCCLASSIFICATIONREFERENCE($,'23-17 15 19 21','Switchable Privacy Glass',#3209,$,$); -#3216=IFCCLASSIFICATIONREFERENCE($,'23-17 15 21','Glazing Components',#3182,$,$); -#3217=IFCCLASSIFICATIONREFERENCE($,'23-17 15 21 11','Glazing Frames',#3216,$,$); -#3218=IFCCLASSIFICATIONREFERENCE($,'23-17 15 21 13','Glazing Sections',#3216,$,$); -#3219=IFCCLASSIFICATIONREFERENCE($,'23-17 15 21 15','Mechanical Glazing Fasteners',#3216,$,$); -#3220=IFCCLASSIFICATIONREFERENCE($,'23-17 15 23','Glazing Accessories',#3182,$,$); -#3221=IFCCLASSIFICATIONREFERENCE($,'23-17 15 23 11','Glazing Beads',#3220,$,$); -#3222=IFCCLASSIFICATIONREFERENCE($,'23-17 15 23 13','Condensation Channels',#3220,$,$); -#3223=IFCCLASSIFICATIONREFERENCE($,'23-17 15 23 15','Glazing Sealants and Tapes',#3220,$,$); -#3224=IFCCLASSIFICATIONREFERENCE($,'23-17 15 23 17','Glazing Gaskets',#3220,$,$); -#3225=IFCCLASSIFICATIONREFERENCE($,'23-17 15 23 19','Glazing Leading Material',#3220,$,$); -#3226=IFCCLASSIFICATIONREFERENCE($,'23-17 15 25','Protective Films',#3182,$,$); -#3227=IFCCLASSIFICATIONREFERENCE($,'23-17 15 25 11','Solar Control Films',#3226,$,$); -#3228=IFCCLASSIFICATIONREFERENCE($,'23-17 15 25 13','Safety Films',#3226,$,$); -#3229=IFCCLASSIFICATIONREFERENCE($,'23-17 15 25 15','Security Films',#3226,$,$); -#3230=IFCCLASSIFICATIONREFERENCE($,'23-17 15 25 17','Decorative Films',#3226,$,$); -#3231=IFCCLASSIFICATIONREFERENCE($,'23-17 17 00','Skylights',#2953,$,$); -#3232=IFCCLASSIFICATIONREFERENCE($,'23-17 17 11','Skylight Components',#3231,$,$); -#3233=IFCCLASSIFICATIONREFERENCE($,'23-17 17 11 11','Skylight Hardware',#3232,$,$); -#3234=IFCCLASSIFICATIONREFERENCE($,'23-17 17 13','Unit Skylights',#3231,$,$); -#3235=IFCCLASSIFICATIONREFERENCE($,'23-17 17 13 11','Domed Unit Skylights',#3234,$,$); -#3236=IFCCLASSIFICATIONREFERENCE($,'23-17 17 13 13','Pyramidal Unit Skylights',#3234,$,$); -#3237=IFCCLASSIFICATIONREFERENCE($,'23-17 17 13 15','Vaulted Unit Skylights',#3234,$,$); -#3238=IFCCLASSIFICATIONREFERENCE($,'23-17 17 13 17','Single Slope Unit Skylights',#3234,$,$); -#3239=IFCCLASSIFICATIONREFERENCE($,'23-17 17 13 19','Octagonal Unit Skylights',#3234,$,$); -#3240=IFCCLASSIFICATIONREFERENCE($,'23-17 17 13 21','Tubular Skylights',#3234,$,$); -#3241=IFCCLASSIFICATIONREFERENCE($,'23-17 17 15','Metal Framed Skylights',#3231,$,$); -#3242=IFCCLASSIFICATIONREFERENCE($,'23-17 17 15 11','Domed Metal Framed Skylights',#3241,$,$); -#3243=IFCCLASSIFICATIONREFERENCE($,'23-17 17 15 13','Pyramidal Metal Framed Skylights',#3241,$,$); -#3244=IFCCLASSIFICATIONREFERENCE($,'23-17 17 15 15','Ridge Metal Framed Skylights',#3241,$,$); -#3245=IFCCLASSIFICATIONREFERENCE($,'23-17 17 15 17','Vaulted Metal Framed Skylights',#3241,$,$); -#3246=IFCCLASSIFICATIONREFERENCE($,'23-17 17 15 19','Single Slope Metal Framed Skylights',#3241,$,$); -#3247=IFCCLASSIFICATIONREFERENCE($,'23-17 17 15 21','Octagonal Metal Framed Skylights',#3241,$,$); -#3248=IFCCLASSIFICATIONREFERENCE($,'23-17 19 00','Hardware for Openings',#2953,$,$); -#3249=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11','Hardware for Doors',#3248,$,$); -#3250=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 11','Rotation, Pivoting Door Gear',#3249,$,$); -#3251=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 13','Sliding Door Gear',#3249,$,$); -#3252=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 15','Door Guiding Hardware',#3249,$,$); -#3253=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 17','Door Holding Hardware',#3249,$,$); -#3254=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 17 11','Door Hold Open Hardware',#3253,$,$); -#3255=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 19','Door Closing Hardware',#3249,$,$); -#3256=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 19 11','Door Closers',#3255,$,$); -#3257=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 19 11 11','Manual Floor Door Closers',#3256,$,$); -#3258=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 19 11 13','Manual Surface Door Closers',#3256,$,$); -#3259=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 19 11 15','Manual Concealed Overhead Door Closers',#3256,$,$); -#3260=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 19 11 17','Power Operator Floor Door Closers',#3256,$,$); -#3261=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 19 11 19','Power Operator Surface Door Closers',#3256,$,$); -#3262=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 19 11 21','Power Operator Concealed Overhead Door Closers',#3256,$,$); -#3263=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21','Door Barrier Locks',#3249,$,$); -#3264=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21 11','Door Deadbolt Locks',#3263,$,$); -#3265=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21 13','Door Chains',#3263,$,$); -#3266=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21 15','Door Electric Strike Locks',#3263,$,$); -#3267=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21 17','Door Electromagnetic Locks',#3263,$,$); -#3268=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21 17 11','Door Time Locks',#3267,$,$); -#3269=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21 17 13','Door Time Delay Combination Locks',#3267,$,$); -#3270=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21 19','Door Latches',#3263,$,$); -#3271=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21 21','Door Mortise Locks',#3263,$,$); -#3272=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21 21 11','Door Electric Mortise Locks',#3271,$,$); -#3273=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21 21 13','Door Electronic Mortise Locks',#3271,$,$); -#3274=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21 23','Door Pin Tumbler Locks',#3263,$,$); -#3275=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21 23 11','Door Tubular Pin Tumbler Locks',#3274,$,$); -#3276=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21 25','Door Flush Bolts',#3263,$,$); -#3277=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 23','Door Cores',#3249,$,$); -#3278=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 25','Door Cylinders',#3249,$,$); -#3279=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 27','Door Key Control Systems',#3249,$,$); -#3280=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 29','Personnel Door Access',#3249,$,$); -#3281=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 29 11','Door Position Switches',#3280,$,$); -#3282=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 29 13','Door Emergency Exit Panic Bars',#3280,$,$); -#3283=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 29 15','Door End of Line Devices',#3280,$,$); -#3284=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 29 17','Door Request to Exit Switches',#3280,$,$); -#3285=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 29 19','Personnel Access Door Keypads',#3280,$,$); -#3286=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 29 19 11','Door Infrared Request to Exit Switches',#3285,$,$); -#3287=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 31','Automatic Door Controls and Operators',#3249,$,$); -#3288=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 31 11','Card Key Door Locking Hardware',#3287,$,$); -#3289=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 31 13','Electrical Door Locking Control',#3287,$,$); -#3290=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 31 15','Electromagnetic Door Holders',#3287,$,$); -#3291=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 31 17','Sensors for Automatic Doors',#3287,$,$); -#3292=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 33','Door Exiting Hardware',#3249,$,$); -#3293=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13','Hardware for Windows',#3248,$,$); -#3294=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 11','Sliding Window Gear',#3293,$,$); -#3295=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 11 11','Horizontal Sliding Window Gear',#3294,$,$); -#3296=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 11 13','Vertical Sliding Window Gear',#3294,$,$); -#3297=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 13','Horizontal Pivoting Window Gear',#3293,$,$); -#3298=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 15','Window Tilt and Turn Gear',#3293,$,$); -#3299=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 17','Louver Gear',#3293,$,$); -#3300=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 19','Automatic Window Equipment',#3293,$,$); -#3301=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 21','Window Barrier Locks',#3293,$,$); -#3302=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 21 11','Window Deadbolt Locks',#3301,$,$); -#3303=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 21 13','Window Latches',#3301,$,$); -#3304=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 21 15','Window Mortise Locks',#3301,$,$); -#3305=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 21 17','Window Flush Bolts',#3301,$,$); -#3306=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 23','Window Lifts',#3293,$,$); -#3307=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 25','Window Operators',#3293,$,$); -#3308=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 25 11','Manual Surface Window Closers',#3307,$,$); -#3309=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 25 13','Manual Concealed Overhead Window Closers',#3307,$,$); -#3310=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 25 15','Power Operator Surface Window Closers',#3307,$,$); -#3311=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 25 17','Power Operator Concealed Overhead Window Closers',#3307,$,$); -#3312=IFCCLASSIFICATIONREFERENCE($,'23-17 19 15','Weatherstripping and Seals',#3248,$,$); -#3313=IFCCLASSIFICATIONREFERENCE($,'23-17 19 15 11','Door Weatherstripping and Seals',#3312,$,$); -#3314=IFCCLASSIFICATIONREFERENCE($,'23-17 19 15 11 11','Acoustic Seals',#3313,$,$); -#3315=IFCCLASSIFICATIONREFERENCE($,'23-17 19 15 11 13','Astragals',#3313,$,$); -#3316=IFCCLASSIFICATIONREFERENCE($,'23-17 19 15 11 15','Perimeter Gasketing',#3313,$,$); -#3317=IFCCLASSIFICATIONREFERENCE($,'23-17 19 15 13','Thresholds',#3312,$,$); -#3318=IFCCLASSIFICATIONREFERENCE($,'23-17 19 15 15','Window Weatherstripping and Seals',#3312,$,$); -#3319=IFCCLASSIFICATIONREFERENCE($,'23-17 19 17','Other Openings Hardware',#3248,$,$); -#3320=IFCCLASSIFICATIONREFERENCE($,'23-17 19 17 11','Door Stops',#3319,$,$); -#3321=IFCCLASSIFICATIONREFERENCE($,'23-17 21 00','Protection of Openings',#2953,$,$); -#3322=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11','Exterior Protection of Openings',#3321,$,$); -#3323=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 11','Projecting Screens',#3322,$,$); -#3324=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 11 11','Solid Canopies',#3323,$,$); -#3325=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 11 13','Louvered Canopies',#3323,$,$); -#3326=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 11 15','Solid Vertical Fins',#3323,$,$); -#3327=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 11 17','Louvered Vertical Fins',#3323,$,$); -#3328=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 11 19','Manual Awnings',#3323,$,$); -#3329=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 11 21','Powered Awnings',#3323,$,$); -#3330=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 13','Exterior Shutters',#3322,$,$); -#3331=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 13 11','Folding Exterior Shutters',#3330,$,$); -#3332=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 13 13','Shutter Components',#3330,$,$); -#3333=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 13 13 11','Roller Shutter Gear',#3332,$,$); -#3334=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 13 13 13','Roller Shutter Sections',#3332,$,$); -#3335=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 13 13 15','Roller Shutter Casings',#3332,$,$); -#3336=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 13 15','Sliding Exterior Shutters',#3330,$,$); -#3337=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 13 17','Swinging Exterior Shutters',#3330,$,$); -#3338=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 13 19','Coiling Exterior Shutters',#3330,$,$); -#3339=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 15','Exterior Louvers and Grilles',#3322,$,$); -#3340=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 15 11','Fixed Exterior Louvers and Grilles',#3339,$,$); -#3341=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 15 13','Roller Exterior Louvers and Grilles',#3339,$,$); -#3342=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 15 15','Sliding Exterior Louvers and Grilles',#3339,$,$); -#3343=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 17','Storm Panels',#3322,$,$); -#3344=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 17 11','Demountable Storm Panels',#3343,$,$); -#3345=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 17 13','Movable Storm Panels',#3343,$,$); -#3346=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13','Interior Window Treatment',#3321,$,$); -#3347=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13 11','Window Blinds',#3346,$,$); -#3348=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13 11 11','Horizontal Window Blinds',#3347,$,$); -#3349=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13 11 13','Vertical Window Blinds',#3347,$,$); -#3350=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13 11 15','Window Blind Components',#3347,$,$); -#3351=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13 11 15 11','Window Slats',#3350,$,$); -#3352=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13 11 15 13','Window Vanes',#3350,$,$); -#3353=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13 11 15 15','Blinds Hardware',#3350,$,$); -#3354=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13 13','Curtains and Drapes',#3346,$,$); -#3355=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13 13 11','Drapery Tracks',#3354,$,$); -#3356=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13 15','Window Interior Shutters',#3346,$,$); -#3357=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13 17','Window Shades',#3346,$,$); -#3358=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13 17 11','Cellular/Pleated Shades',#3357,$,$); -#3359=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13 17 13','Roller Shades',#3357,$,$); -#3360=IFCCLASSIFICATIONREFERENCE($,'23-17 21 15','Fire and Smoke Shutters and Curtains',#3321,$,$); -#3361=IFCCLASSIFICATIONREFERENCE($,'23-17 21 15 11','Fire Shutters',#3360,$,$); -#3362=IFCCLASSIFICATIONREFERENCE($,'23-17 21 15 11 11','Vertical Fire Shutters',#3361,$,$); -#3363=IFCCLASSIFICATIONREFERENCE($,'23-17 21 15 11 13','Horizontal Fire Shutters',#3361,$,$); -#3364=IFCCLASSIFICATIONREFERENCE($,'23-17 21 15 13','Smoke Curtains',#3360,$,$); -#3365=IFCCLASSIFICATIONREFERENCE($,'23-17 21 15 13 11','Water Spray Smoke Curtains',#3364,$,$); -#3366=IFCCLASSIFICATIONREFERENCE($,'23-17 21 15 15','Smoke Shutters',#3360,$,$); -#3367=IFCCLASSIFICATIONREFERENCE($,'23-17 21 17','Insect Screens',#3321,$,$); -#3368=IFCCLASSIFICATIONREFERENCE($,'23-17 21 17 11','Complete Insect Screens',#3367,$,$); -#3369=IFCCLASSIFICATIONREFERENCE($,'23-17 21 17 13','Components',#3367,$,$); -#3370=IFCCLASSIFICATIONREFERENCE($,'23-17 21 17 13 11','Frames for Insect Screens',#3369,$,$); -#3371=IFCCLASSIFICATIONREFERENCE($,'23-17 21 17 13 13','Mesh for Insect Screens',#3369,$,$); -#3372=IFCCLASSIFICATIONREFERENCE($,'23-17 23 00','Circulation and Escape Products',#2953,$,$); -#3373=IFCCLASSIFICATIONREFERENCE($,'23-17 23 11','Ramps',#3372,$,$); -#3374=IFCCLASSIFICATIONREFERENCE($,'23-17 23 13','Walkways',#3372,$,$); -#3375=IFCCLASSIFICATIONREFERENCE($,'23-17 23 15','Ladders',#3372,$,$); -#3376=IFCCLASSIFICATIONREFERENCE($,'23-17 23 15 11','Ladder Component Products',#3375,$,$); -#3377=IFCCLASSIFICATIONREFERENCE($,'23-17 23 15 11 11','Ladder Hardware',#3376,$,$); -#3378=IFCCLASSIFICATIONREFERENCE($,'23-17 23 15 11 13','Rungs',#3376,$,$); -#3379=IFCCLASSIFICATIONREFERENCE($,'23-17 23 15 13','Vertical Ladders',#3375,$,$); -#3380=IFCCLASSIFICATIONREFERENCE($,'23-17 23 15 15','Ship Ladders',#3375,$,$); -#3381=IFCCLASSIFICATIONREFERENCE($,'23-17 23 17','Stairs',#3372,$,$); -#3382=IFCCLASSIFICATIONREFERENCE($,'23-17 23 17 11','Stair Component Products',#3381,$,$); -#3383=IFCCLASSIFICATIONREFERENCE($,'23-17 23 17 11 11','Stair Treads',#3382,$,$); -#3384=IFCCLASSIFICATIONREFERENCE($,'23-17 23 17 11 13','Stair Nosings',#3382,$,$); -#3385=IFCCLASSIFICATIONREFERENCE($,'23-17 23 17 11 15','Stair Tread Coverings',#3382,$,$); -#3386=IFCCLASSIFICATIONREFERENCE($,'23-17 23 17 11 17','Stair Railings',#3382,$,$); -#3387=IFCCLASSIFICATIONREFERENCE($,'23-17 23 17 11 19','Stair Handrails',#3382,$,$); -#3388=IFCCLASSIFICATIONREFERENCE($,'23-17 23 17 11 21','Stair Barrier Gates',#3382,$,$); -#3389=IFCCLASSIFICATIONREFERENCE($,'23-17 23 17 13','Spiral Stairs',#3381,$,$); -#3390=IFCCLASSIFICATIONREFERENCE($,'23-17 23 17 13 11','Metal Spiral Stairs',#3389,$,$); -#3391=IFCCLASSIFICATIONREFERENCE($,'23-17 23 17 13 13','Wood Spiral Stairs',#3389,$,$); -#3392=IFCCLASSIFICATIONREFERENCE($,'23-17 23 17 15','Retractable Stairs',#3381,$,$); -#3393=IFCCLASSIFICATIONREFERENCE($,'23-17 23 19','Fire Escapes',#3372,$,$); -#3394=IFCCLASSIFICATIONREFERENCE($,'23-17 23 19 11','Escape Ladders, Stairs',#3393,$,$); -#3395=IFCCLASSIFICATIONREFERENCE($,'23-17 23 19 11 11','Fire Escapes',#3394,$,$); -#3396=IFCCLASSIFICATIONREFERENCE($,'23-17 23 19 13','Escape Slides',#3393,$,$); -#3397=IFCCLASSIFICATIONREFERENCE($,'23-17 23 21','Evacuation Equipment',#3372,$,$); -#3398=IFCCLASSIFICATIONREFERENCE($,'23-17 23 21 11','Evacuation Slings',#3397,$,$); -#3399=IFCCLASSIFICATIONREFERENCE($,'23-17 23 21 13','Evacuation Chairs',#3397,$,$); -#3400=IFCCLASSIFICATIONREFERENCE($,'23-17 25 00','Circulation Guiding and Protection Products',#2953,$,$); -#3401=IFCCLASSIFICATIONREFERENCE($,'23-17 25 11','Guardrails',#3400,$,$); -#3402=IFCCLASSIFICATIONREFERENCE($,'23-17 25 11 11','Guardrail Component Products',#3401,$,$); -#3403=IFCCLASSIFICATIONREFERENCE($,'23-17 25 11 11 11','Cable Infill Systems',#3402,$,$); -#3404=IFCCLASSIFICATIONREFERENCE($,'23-17 25 11 11 13','Infill Panels',#3402,$,$); -#3405=IFCCLASSIFICATIONREFERENCE($,'23-17 25 11 11 15','Posts, Newel Posts, Pickets',#3402,$,$); -#3406=IFCCLASSIFICATIONREFERENCE($,'23-17 25 11 11 17','Railing',#3402,$,$); -#3407=IFCCLASSIFICATIONREFERENCE($,'23-17 25 13','Handrails',#3400,$,$); -#3408=IFCCLASSIFICATIONREFERENCE($,'23-17 25 13 11','Rope Handrails',#3407,$,$); -#3409=IFCCLASSIFICATIONREFERENCE($,'23-17 25 13 13','Capping',#3407,$,$); -#3410=IFCCLASSIFICATIONREFERENCE($,'23-17 25 13 15','Chain Handrails',#3407,$,$); -#3411=IFCCLASSIFICATIONREFERENCE($,'23-17 25 15','Impact Protection Products',#3400,$,$); -#3412=IFCCLASSIFICATIONREFERENCE($,'23-17 25 15 11','Impact Guard Rails',#3411,$,$); -#3413=IFCCLASSIFICATIONREFERENCE($,'23-17 25 15 11 11','Bumper Guards',#3412,$,$); -#3414=IFCCLASSIFICATIONREFERENCE($,'23-17 25 15 13','Corner Guards',#3411,$,$); -#3415=IFCCLASSIFICATIONREFERENCE($,'23-17 25 15 15','Column Protectors',#3411,$,$); -#3416=IFCCLASSIFICATIONREFERENCE($,'23-17 25 15 17','Door and Wall Protector Products',#3411,$,$); -#3417=IFCCLASSIFICATIONREFERENCE($,'23-17 25 15 17 11','Impact Resistant Wall Protection Products',#3416,$,$); -#3418=IFCCLASSIFICATIONREFERENCE($,'23-19 00 00','Specialty Products',#1604,$,$); -#3419=IFCCLASSIFICATIONREFERENCE($,'23-19 11 00','Information Display Specialties',#3418,$,$); -#3420=IFCCLASSIFICATIONREFERENCE($,'23-19 11 11','Information Signs',#3419,$,$); -#3421=IFCCLASSIFICATIONREFERENCE($,'23-19 11 13','Display Lettering',#3419,$,$); -#3422=IFCCLASSIFICATIONREFERENCE($,'23-19 11 15','Display Numerals',#3419,$,$); -#3423=IFCCLASSIFICATIONREFERENCE($,'23-19 11 17','Notice Boards',#3419,$,$); -#3424=IFCCLASSIFICATIONREFERENCE($,'23-19 11 19','Writing Boards',#3419,$,$); -#3425=IFCCLASSIFICATIONREFERENCE($,'23-19 11 19 11','Interactive Multi Media Whiteboards',#3424,$,$); -#3426=IFCCLASSIFICATIONREFERENCE($,'23-19 11 19 13','Chalk Boards',#3424,$,$); -#3427=IFCCLASSIFICATIONREFERENCE($,'23-19 11 19 15','Dry Erase Boards',#3424,$,$); -#3428=IFCCLASSIFICATIONREFERENCE($,'23-19 11 19 17','Drawing Boards',#3424,$,$); -#3429=IFCCLASSIFICATIONREFERENCE($,'23-19 11 21','Plaques',#3419,$,$); -#3430=IFCCLASSIFICATIONREFERENCE($,'23-19 11 23','Poster Display Units',#3419,$,$); -#3431=IFCCLASSIFICATIONREFERENCE($,'23-19 11 25','Display Screens',#3419,$,$); -#3432=IFCCLASSIFICATIONREFERENCE($,'23-19 11 27','Pictograms',#3419,$,$); -#3433=IFCCLASSIFICATIONREFERENCE($,'23-19 11 29','Directory Boards',#3419,$,$); -#3434=IFCCLASSIFICATIONREFERENCE($,'23-19 11 31','Electronic Copy Boards',#3419,$,$); -#3435=IFCCLASSIFICATIONREFERENCE($,'23-19 11 33','Magnetic Boards',#3419,$,$); -#3436=IFCCLASSIFICATIONREFERENCE($,'23-19 13 00','Lockers',#3418,$,$); -#3437=IFCCLASSIFICATIONREFERENCE($,'23-19 13 11','Metal Lockers',#3436,$,$); -#3438=IFCCLASSIFICATIONREFERENCE($,'23-19 13 13','Plastic Laminate Lockers',#3436,$,$); -#3439=IFCCLASSIFICATIONREFERENCE($,'23-19 13 15','Solid Core Lockers',#3436,$,$); -#3440=IFCCLASSIFICATIONREFERENCE($,'23-19 15 00','Communication Specialties',#3418,$,$); -#3441=IFCCLASSIFICATIONREFERENCE($,'23-19 15 11','Mail Boxes',#3440,$,$); -#3442=IFCCLASSIFICATIONREFERENCE($,'23-19 15 13','Mail Racks',#3440,$,$); -#3443=IFCCLASSIFICATIONREFERENCE($,'23-19 15 15','Pigeonholes',#3440,$,$); -#3444=IFCCLASSIFICATIONREFERENCE($,'23-19 15 17','Mail Trolleys',#3440,$,$); -#3445=IFCCLASSIFICATIONREFERENCE($,'23-19 15 19','Mail Handling Equipment',#3440,$,$); -#3446=IFCCLASSIFICATIONREFERENCE($,'23-19 15 21','Telephone Booths',#3440,$,$); -#3447=IFCCLASSIFICATIONREFERENCE($,'23-19 17 00','Fireplaces',#3418,$,$); -#3448=IFCCLASSIFICATIONREFERENCE($,'23-19 17 11','Electric Fireplace',#3447,$,$); -#3449=IFCCLASSIFICATIONREFERENCE($,'23-19 17 13','Fuel Oil Fireplace',#3447,$,$); -#3450=IFCCLASSIFICATIONREFERENCE($,'23-19 17 15','Gas Fireplace',#3447,$,$); -#3451=IFCCLASSIFICATIONREFERENCE($,'23-19 17 17','Solid Fuel Fireplace',#3447,$,$); -#3452=IFCCLASSIFICATIONREFERENCE($,'23-19 17 19','Fireplace Doors',#3447,$,$); -#3453=IFCCLASSIFICATIONREFERENCE($,'23-19 17 21','Fireplace Water Heaters',#3447,$,$); -#3454=IFCCLASSIFICATIONREFERENCE($,'23-19 19 00','Flue and Chimney Products',#3418,$,$); -#3455=IFCCLASSIFICATIONREFERENCE($,'23-19 19 11','Complete Flue and Chimney Systems',#3454,$,$); -#3456=IFCCLASSIFICATIONREFERENCE($,'23-19 19 11 11','Chimney Gas Vents',#3455,$,$); -#3457=IFCCLASSIFICATIONREFERENCE($,'23-19 19 11 13','Fabricated Stacks',#3455,$,$); -#3458=IFCCLASSIFICATIONREFERENCE($,'23-19 19 11 15','Fabricated Breechings and Accessories',#3455,$,$); -#3459=IFCCLASSIFICATIONREFERENCE($,'23-19 19 11 17','Insulated Sectional Chimneys',#3455,$,$); -#3460=IFCCLASSIFICATIONREFERENCE($,'23-19 19 13','Fireplace Ductwork',#3454,$,$); -#3461=IFCCLASSIFICATIONREFERENCE($,'23-19 19 13 11','Fireplace B Vent Ductwork',#3460,$,$); -#3462=IFCCLASSIFICATIONREFERENCE($,'23-19 19 13 13','Fireplace Direct Vent Ductwork',#3460,$,$); -#3463=IFCCLASSIFICATIONREFERENCE($,'23-19 19 13 15','Fireplace Free Vent Ductwork',#3460,$,$); -#3464=IFCCLASSIFICATIONREFERENCE($,'23-19 19 13 17','Fireplace Tri Wall Vent Ductwork',#3460,$,$); -#3465=IFCCLASSIFICATIONREFERENCE($,'23-19 19 13 19','Fireplace Dampers',#3460,$,$); -#3466=IFCCLASSIFICATIONREFERENCE($,'23-19 19 15','Flue and Chimney Systems Components',#3454,$,$); -#3467=IFCCLASSIFICATIONREFERENCE($,'23-19 19 15 11','Draft Control Devices',#3466,$,$); -#3468=IFCCLASSIFICATIONREFERENCE($,'23-19 19 15 13','Fireplace Lintels',#3466,$,$); -#3469=IFCCLASSIFICATIONREFERENCE($,'23-19 19 15 15','Flue Linings',#3466,$,$); -#3470=IFCCLASSIFICATIONREFERENCE($,'23-19 19 15 17','Flue Caps',#3466,$,$); -#3471=IFCCLASSIFICATIONREFERENCE($,'23-19 19 15 19','Flue Cowls',#3466,$,$); -#3472=IFCCLASSIFICATIONREFERENCE($,'23-19 19 15 21','Chimney Dampers',#3466,$,$); -#3473=IFCCLASSIFICATIONREFERENCE($,'23-19 19 15 23','Fire Shutter Extinguishers',#3466,$,$); -#3474=IFCCLASSIFICATIONREFERENCE($,'23-19 19 15 25','Flue Gas Purifiers',#3466,$,$); -#3475=IFCCLASSIFICATIONREFERENCE($,'23-19 21 00','Hearths',#3418,$,$); -#3476=IFCCLASSIFICATIONREFERENCE($,'23-19 23 00','Kilns',#3418,$,$); -#3477=IFCCLASSIFICATIONREFERENCE($,'23-19 25 00','Pest Control Devices',#3418,$,$); -#3478=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11','Bird Control Devices',#3477,$,$); -#3479=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 11','Roost Inhibitors',#3478,$,$); -#3480=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 11 11','Bird Wire',#3479,$,$); -#3481=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 11 13','Bird Spikes',#3479,$,$); -#3482=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 11 15','Bird Netting',#3479,$,$); -#3483=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 13','Bird Flight Diverters',#3478,$,$); -#3484=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 15','Bird Repellant Devices',#3478,$,$); -#3485=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 15 11','Sonic Repellant Devices',#3484,$,$); -#3486=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 15 13','Ultra Sonic Repellant Devices',#3484,$,$); -#3487=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 15 15','Visual Devices',#3484,$,$); -#3488=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 17','Bird Attractors',#3478,$,$); -#3489=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 19','Bird Control Accessories',#3478,$,$); -#3490=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 19 11','Mounting Clips',#3489,$,$); -#3491=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 19 13','Extension Speakers',#3489,$,$); -#3492=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 19 15','Solar Panels',#3489,$,$); -#3493=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 19 17','Spikes Adhesives',#3489,$,$); -#3494=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 19 19','Foot Pumps',#3489,$,$); -#3495=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 19 21','Caulking Guns',#3489,$,$); -#3496=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13','Insect Control Devices',#3477,$,$); -#3497=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 11','Electronic Insect Repellers',#3496,$,$); -#3498=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 11 11','Automatic Misting Systems',#3497,$,$); -#3499=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 11 13','Vacuum System s',#3497,$,$); -#3500=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 11 15','Sonic Repellers',#3497,$,$); -#3501=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 11 17','Ultrasonic Repellers',#3497,$,$); -#3502=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 11 19','Electromagnetic Repellers',#3497,$,$); -#3503=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 13','Fly Traps',#3496,$,$); -#3504=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 15','Screens',#3496,$,$); -#3505=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 17','Foam Sealants',#3496,$,$); -#3506=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 19','Fly Boards',#3496,$,$); -#3507=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 21','Insect Control Accessories',#3496,$,$); -#3508=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 21 11','Nozzles',#3507,$,$); -#3509=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 21 13','Tubing',#3507,$,$); -#3510=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 21 15','Risers',#3507,$,$); -#3511=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 21 17','Fittings',#3507,$,$); -#3512=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 21 19','Remote Controls',#3507,$,$); -#3513=IFCCLASSIFICATIONREFERENCE($,'23-19 25 15','Rodent Control Devices',#3477,$,$); -#3514=IFCCLASSIFICATIONREFERENCE($,'23-19 25 15 11','Traps',#3513,$,$); -#3515=IFCCLASSIFICATIONREFERENCE($,'23-19 25 15 11 11','Snap Traps',#3514,$,$); -#3516=IFCCLASSIFICATIONREFERENCE($,'23-19 25 15 11 13','Glue Traps',#3514,$,$); -#3517=IFCCLASSIFICATIONREFERENCE($,'23-19 25 15 11 15','Sticky Traps',#3514,$,$); -#3518=IFCCLASSIFICATIONREFERENCE($,'23-19 25 15 11 17','Electronic Traps',#3514,$,$); -#3519=IFCCLASSIFICATIONREFERENCE($,'23-19 25 15 13','Ultrasonic Rodent Control Devices',#3513,$,$); -#3520=IFCCLASSIFICATIONREFERENCE($,'23-19 25 15 15','Electronic Rodent Control Devices',#3513,$,$); -#3521=IFCCLASSIFICATIONREFERENCE($,'23-19 25 15 17','Proofing Devices',#3513,$,$); -#3522=IFCCLASSIFICATIONREFERENCE($,'23-19 25 15 19','Tracking Products',#3513,$,$); -#3523=IFCCLASSIFICATIONREFERENCE($,'23-19 25 15 21','Spray Devices',#3513,$,$); -#3524=IFCCLASSIFICATIONREFERENCE($,'23-19 25 15 23','Rodent Control Accessories',#3513,$,$); -#3525=IFCCLASSIFICATIONREFERENCE($,'23-19 27 00','Manufactured Exterior Specialties',#3418,$,$); -#3526=IFCCLASSIFICATIONREFERENCE($,'23-19 27 11','Weathervanes',#3525,$,$); -#3527=IFCCLASSIFICATIONREFERENCE($,'23-19 27 13','Clocks',#3525,$,$); -#3528=IFCCLASSIFICATIONREFERENCE($,'23-19 27 15','Cupolas',#3525,$,$); -#3529=IFCCLASSIFICATIONREFERENCE($,'23-19 27 17','Spires',#3525,$,$); -#3530=IFCCLASSIFICATIONREFERENCE($,'23-19 27 19','Steeples',#3525,$,$); -#3531=IFCCLASSIFICATIONREFERENCE($,'23-19 27 21','Towers',#3525,$,$); -#3532=IFCCLASSIFICATIONREFERENCE($,'23-19 27 23','Industrial Breechings',#3525,$,$); -#3533=IFCCLASSIFICATIONREFERENCE($,'23-19 27 23 11','Industrial Breechings',#3532,$,$); -#3534=IFCCLASSIFICATIONREFERENCE($,'23-19 27 23 13','Fabricated Industrial Breechings',#3532,$,$); -#3535=IFCCLASSIFICATIONREFERENCE($,'23-19 27 23 15','Fabricated Industrial Breechings Accessories',#3532,$,$); -#3536=IFCCLASSIFICATIONREFERENCE($,'23-19 27 25','Industrial Chimneys',#3525,$,$); -#3537=IFCCLASSIFICATIONREFERENCE($,'23-19 27 25 11','Industrial Chimney Shafts',#3536,$,$); -#3538=IFCCLASSIFICATIONREFERENCE($,'23-19 27 25 13','Industrial Chimney Linings',#3536,$,$); -#3539=IFCCLASSIFICATIONREFERENCE($,'23-19 27 25 15','Industrial Chimney Draft Control Devices',#3536,$,$); -#3540=IFCCLASSIFICATIONREFERENCE($,'23-19 27 25 17','Industrial Insulated Sectional Chimneys',#3536,$,$); -#3541=IFCCLASSIFICATIONREFERENCE($,'23-19 27 27','Industrial Stacks',#3525,$,$); -#3542=IFCCLASSIFICATIONREFERENCE($,'23-19 29 00','Complete Buildings',#3418,$,$); -#3543=IFCCLASSIFICATIONREFERENCE($,'23-19 29 11','Pre Engineered Structures',#3542,$,$); -#3544=IFCCLASSIFICATIONREFERENCE($,'23-19 29 11 11','Pre Engineered Structure Component',#3543,$,$); -#3545=IFCCLASSIFICATIONREFERENCE($,'23-19 29 11 11 11','Lift Shaft Components',#3544,$,$); -#3546=IFCCLASSIFICATIONREFERENCE($,'23-19 29 11 13','Framed Pre Engineered Buildings',#3543,$,$); -#3547=IFCCLASSIFICATIONREFERENCE($,'23-19 29 11 15','Panel Structure Pre Engineered Buildings',#3543,$,$); -#3548=IFCCLASSIFICATIONREFERENCE($,'23-19 29 11 17','Cubicle Structure Pre Engineered Buildings',#3543,$,$); -#3549=IFCCLASSIFICATIONREFERENCE($,'23-19 29 11 19','Air Supported Pre Engineered Buildings',#3543,$,$); -#3550=IFCCLASSIFICATIONREFERENCE($,'23-19 29 11 21','Cable Supported Pre Engineered Buildings',#3543,$,$); -#3551=IFCCLASSIFICATIONREFERENCE($,'23-19 29 11 23','Fabric Pre Engineered Building Structures',#3543,$,$); -#3552=IFCCLASSIFICATIONREFERENCE($,'23-19 29 11 25','Prefabricated Dome Structures',#3543,$,$); -#3553=IFCCLASSIFICATIONREFERENCE($,'23-19 29 11 27','Portable Buildings',#3543,$,$); -#3554=IFCCLASSIFICATIONREFERENCE($,'23-19 29 11 29','Mobile Buildings',#3543,$,$); -#3555=IFCCLASSIFICATIONREFERENCE($,'23-19 29 13','Covers and Shelters',#3542,$,$); -#3556=IFCCLASSIFICATIONREFERENCE($,'23-19 29 13 11','General Purpose Shelters',#3555,$,$); -#3557=IFCCLASSIFICATIONREFERENCE($,'23-19 29 13 13','Shelters for Public Transport',#3555,$,$); -#3558=IFCCLASSIFICATIONREFERENCE($,'23-19 29 13 13 11','Bus Stop Shelters',#3557,$,$); -#3559=IFCCLASSIFICATIONREFERENCE($,'23-19 29 13 13 13','Train Platform Shelters',#3557,$,$); -#3560=IFCCLASSIFICATIONREFERENCE($,'23-19 29 13 15','Walkway Coverings',#3555,$,$); -#3561=IFCCLASSIFICATIONREFERENCE($,'23-19 29 13 17','Shelters for Civil Protection',#3555,$,$); -#3562=IFCCLASSIFICATIONREFERENCE($,'23-19 29 13 19','Animal Shelters',#3555,$,$); -#3563=IFCCLASSIFICATIONREFERENCE($,'23-19 29 13 19 11','Kennels',#3562,$,$); -#3564=IFCCLASSIFICATIONREFERENCE($,'23-19 29 13 21','Car Shelters',#3555,$,$); -#3565=IFCCLASSIFICATIONREFERENCE($,'23-19 29 13 23','Shelters for Services',#3555,$,$); -#3566=IFCCLASSIFICATIONREFERENCE($,'23-19 29 13 25','Garden Umbrellas',#3555,$,$); -#3567=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15','Special Purpose Buildings',#3542,$,$); -#3568=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 11','Observatories',#3567,$,$); -#3569=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 13','Control Booths',#3567,$,$); -#3570=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 15','Greenhouses',#3567,$,$); -#3571=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 15 11','Glazed Greenhouse Structures',#3570,$,$); -#3572=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 17','Summerhouses',#3567,$,$); -#3573=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 17 11','Gazebos',#3572,$,$); -#3574=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 17 13','Pavilions',#3572,$,$); -#3575=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 19','Kiosks',#3567,$,$); -#3576=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 21','Public Restrooms',#3567,$,$); -#3577=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 23','Sauna Buildings',#3567,$,$); -#3578=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 25','Funerary Construction Products',#3567,$,$); -#3579=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 25 11','Preassembled Mausoleums',#3578,$,$); -#3580=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 27','General Purpose Booths',#3567,$,$); -#3581=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 27 11','Ticket Booths',#3580,$,$); -#3582=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 27 13','Parking Attendant Booths',#3580,$,$); -#3583=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 27 15','Toll Booths',#3580,$,$); -#3584=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 27 17','Guard Booths',#3580,$,$); -#3585=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 27 19','Valet Booths',#3580,$,$); -#3586=IFCCLASSIFICATIONREFERENCE($,'23-19 29 17','Building Modules',#3542,$,$); -#3587=IFCCLASSIFICATIONREFERENCE($,'23-19 29 17 11','Prison Cells',#3586,$,$); -#3588=IFCCLASSIFICATIONREFERENCE($,'23-19 29 17 13','Hotel Rooms',#3586,$,$); -#3589=IFCCLASSIFICATIONREFERENCE($,'23-19 29 17 15','Dormitory Rooms',#3586,$,$); -#3590=IFCCLASSIFICATIONREFERENCE($,'23-19 29 19','Integrated Assemblies',#3542,$,$); -#3591=IFCCLASSIFICATIONREFERENCE($,'23-19 29 19 11','Sound, Vibration and Seismic Control Products',#3590,$,$); -#3592=IFCCLASSIFICATIONREFERENCE($,'23-19 29 19 11 11','Floating Floor Construction Products',#3591,$,$); -#3593=IFCCLASSIFICATIONREFERENCE($,'23-19 31 00','Room Units',#3418,$,$); -#3594=IFCCLASSIFICATIONREFERENCE($,'23-19 31 11','General Purpose Room Units',#3593,$,$); -#3595=IFCCLASSIFICATIONREFERENCE($,'23-19 31 11 11','Prefabricated General Purpose Rooms',#3594,$,$); -#3596=IFCCLASSIFICATIONREFERENCE($,'23-19 31 13','Storage Room Units',#3593,$,$); -#3597=IFCCLASSIFICATIONREFERENCE($,'23-19 31 15','Special Purpose Rooms',#3593,$,$); -#3598=IFCCLASSIFICATIONREFERENCE($,'23-19 31 15 11','Athletic Rooms',#3597,$,$); -#3599=IFCCLASSIFICATIONREFERENCE($,'23-19 31 15 11 11','Handball Racquetball Courts',#3598,$,$); -#3600=IFCCLASSIFICATIONREFERENCE($,'23-19 31 15 13','Conservatories',#3597,$,$); -#3601=IFCCLASSIFICATIONREFERENCE($,'23-19 31 15 13 11','Solarium Specialties',#3600,$,$); -#3602=IFCCLASSIFICATIONREFERENCE($,'23-19 31 15 15','Planetariums',#3597,$,$); -#3603=IFCCLASSIFICATIONREFERENCE($,'23-19 31 15 17','Saunas',#3597,$,$); -#3604=IFCCLASSIFICATIONREFERENCE($,'23-19 31 15 19','Steam Baths',#3597,$,$); -#3605=IFCCLASSIFICATIONREFERENCE($,'23-19 31 17','Sanitary Room Units',#3593,$,$); -#3606=IFCCLASSIFICATIONREFERENCE($,'23-19 31 17 11','Bathroom Units',#3605,$,$); -#3607=IFCCLASSIFICATIONREFERENCE($,'23-19 31 17 13','Lavatory Units',#3605,$,$); -#3608=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19','Controlled Environment Rooms',#3593,$,$); -#3609=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 11','Clean Rooms',#3608,$,$); -#3610=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 13','Insulated Rooms',#3608,$,$); -#3611=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 13 11','Cold Storage Rooms',#3610,$,$); -#3612=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 15','Sound Conditioned Rooms',#3608,$,$); -#3613=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 15 11','Practice Booths',#3612,$,$); -#3614=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 17','Hyperbaric Rooms',#3608,$,$); -#3615=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 19','Radiation Protected Rooms',#3608,$,$); -#3616=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 19 11','Electromagnetic Shielded Rooms',#3615,$,$); -#3617=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 19 13','RF Shielded Rooms',#3615,$,$); -#3618=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 19 15','BO Shielded Rooms',#3615,$,$); -#3619=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 19 17','Radio Frequency Protected Rooms',#3615,$,$); -#3620=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 19 19','X Ray Protected Rooms',#3615,$,$); -#3621=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 19 21','Nuclear Radiation Protected Rooms',#3615,$,$); -#3622=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 19 23','High Energy Magnetic Pulse Protected Rooms',#3615,$,$); -#3623=IFCCLASSIFICATIONREFERENCE($,'23-19 31 21','Plant and Control Room Units',#3593,$,$); -#3624=IFCCLASSIFICATIONREFERENCE($,'23-19 31 21 11','Plant Office Shelters and Booths',#3623,$,$); -#3625=IFCCLASSIFICATIONREFERENCE($,'23-19 31 23','Corridor Units',#3593,$,$); -#3626=IFCCLASSIFICATIONREFERENCE($,'23-21 00 00','Furnishings, Fixtures and Equipment Products',#1604,$,$); -#3627=IFCCLASSIFICATIONREFERENCE($,'23-21 11 00','Commercial Furniture',#3626,$,$); -#3628=IFCCLASSIFICATIONREFERENCE($,'23-21 11 11','Commercial Storage Units',#3627,$,$); -#3629=IFCCLASSIFICATIONREFERENCE($,'23-21 11 11 11','Commercial Storage Shelves',#3628,$,$); -#3630=IFCCLASSIFICATIONREFERENCE($,'23-21 11 11 13','Commercial Storage Supports',#3628,$,$); -#3631=IFCCLASSIFICATIONREFERENCE($,'23-21 11 11 15','Commercial Storage Racking',#3628,$,$); -#3632=IFCCLASSIFICATIONREFERENCE($,'23-21 11 11 17','Commercial Mobile Storage Units',#3628,$,$); -#3633=IFCCLASSIFICATIONREFERENCE($,'23-21 11 11 19','Commercial Filing Cabinets',#3628,$,$); -#3634=IFCCLASSIFICATIONREFERENCE($,'23-21 11 11 21','Architecture Plan Chests',#3628,$,$); -#3635=IFCCLASSIFICATIONREFERENCE($,'23-21 11 11 23','Commercial Desks',#3628,$,$); -#3636=IFCCLASSIFICATIONREFERENCE($,'23-21 11 11 25','Commercial Bookcases',#3628,$,$); -#3637=IFCCLASSIFICATIONREFERENCE($,'23-21 11 11 27','Commercial Key Hangers',#3628,$,$); -#3638=IFCCLASSIFICATIONREFERENCE($,'23-21 13 00','Retail and Office Equipment and Furnishings',#3626,$,$); -#3639=IFCCLASSIFICATIONREFERENCE($,'23-21 13 11','Registration Equipment',#3638,$,$); -#3640=IFCCLASSIFICATIONREFERENCE($,'23-21 13 13','Checkroom Equipment',#3638,$,$); -#3641=IFCCLASSIFICATIONREFERENCE($,'23-21 13 15','Mercantile Equipment and Furnishings',#3638,$,$); -#3642=IFCCLASSIFICATIONREFERENCE($,'23-21 13 17','Barber Shop Equipment',#3638,$,$); -#3643=IFCCLASSIFICATIONREFERENCE($,'23-21 13 19','Beauty Shop Equipment',#3638,$,$); -#3644=IFCCLASSIFICATIONREFERENCE($,'23-21 13 21','Cash Registers',#3638,$,$); -#3645=IFCCLASSIFICATIONREFERENCE($,'23-21 13 23','Checkout Equipment',#3638,$,$); -#3646=IFCCLASSIFICATIONREFERENCE($,'23-21 13 25','Office Equipment',#3638,$,$); -#3647=IFCCLASSIFICATIONREFERENCE($,'23-21 13 25 11','Drafting Equipment',#3646,$,$); -#3648=IFCCLASSIFICATIONREFERENCE($,'23-21 13 25 13','Plotters',#3646,$,$); -#3649=IFCCLASSIFICATIONREFERENCE($,'23-21 13 25 15','Drawing Equipment',#3646,$,$); -#3650=IFCCLASSIFICATIONREFERENCE($,'23-21 13 25 17','Office Accessories',#3646,$,$); -#3651=IFCCLASSIFICATIONREFERENCE($,'23-21 15 00','Wardrobe and Closet Specialties',#3626,$,$); -#3652=IFCCLASSIFICATIONREFERENCE($,'23-21 15 11','Wardrobes',#3651,$,$); -#3653=IFCCLASSIFICATIONREFERENCE($,'23-21 15 13','Chests of Drawers',#3651,$,$); -#3654=IFCCLASSIFICATIONREFERENCE($,'23-21 15 15','Clothing Lockers',#3651,$,$); -#3655=IFCCLASSIFICATIONREFERENCE($,'23-21 15 17','Clothing Racks',#3651,$,$); -#3656=IFCCLASSIFICATIONREFERENCE($,'23-21 15 17 11','Coat Racks',#3655,$,$); -#3657=IFCCLASSIFICATIONREFERENCE($,'23-21 15 17 13','Hat Racks',#3655,$,$); -#3658=IFCCLASSIFICATIONREFERENCE($,'23-21 15 19','Clothing Hangers',#3651,$,$); -#3659=IFCCLASSIFICATIONREFERENCE($,'23-21 15 19 11','Shoe Trees',#3658,$,$); -#3660=IFCCLASSIFICATIONREFERENCE($,'23-21 15 19 13','Coat Hooks',#3658,$,$); -#3661=IFCCLASSIFICATIONREFERENCE($,'23-21 15 19 15','Coat Hangers',#3658,$,$); -#3662=IFCCLASSIFICATIONREFERENCE($,'23-21 15 19 17','Coat Rails',#3658,$,$); -#3663=IFCCLASSIFICATIONREFERENCE($,'23-21 15 21','Cloakroom Units',#3651,$,$); -#3664=IFCCLASSIFICATIONREFERENCE($,'23-21 15 23','Umbrella Storage Stands',#3651,$,$); -#3665=IFCCLASSIFICATIONREFERENCE($,'23-21 15 25','Checkroom Equipment',#3651,$,$); -#3666=IFCCLASSIFICATIONREFERENCE($,'23-21 15 25 11','Manual Checkroom Equipment',#3665,$,$); -#3667=IFCCLASSIFICATIONREFERENCE($,'23-21 15 25 13','Automated Checkroom Equipment',#3665,$,$); -#3668=IFCCLASSIFICATIONREFERENCE($,'23-21 15 27','Clothing Shelving Units',#3651,$,$); -#3669=IFCCLASSIFICATIONREFERENCE($,'23-21 15 27 11','Clothing Shelves',#3668,$,$); -#3670=IFCCLASSIFICATIONREFERENCE($,'23-21 15 27 13','Clothing Shelving and Storage Units',#3668,$,$); -#3671=IFCCLASSIFICATIONREFERENCE($,'23-21 17 00','Interior Refuse Disposal Furniture',#3626,$,$); -#3672=IFCCLASSIFICATIONREFERENCE($,'23-21 17 11','Interior Waste Bins',#3671,$,$); -#3673=IFCCLASSIFICATIONREFERENCE($,'23-21 17 13','Interior Ash Trays',#3671,$,$); -#3674=IFCCLASSIFICATIONREFERENCE($,'23-21 17 15','Interior Refuse Holders',#3671,$,$); -#3675=IFCCLASSIFICATIONREFERENCE($,'23-21 19 00','Casework',#3626,$,$); -#3676=IFCCLASSIFICATIONREFERENCE($,'23-21 19 11','Modular General Casework',#3675,$,$); -#3677=IFCCLASSIFICATIONREFERENCE($,'23-21 19 11 11','Metal Modular General Casework',#3676,$,$); -#3678=IFCCLASSIFICATIONREFERENCE($,'23-21 19 11 13','Wood Modular General Casework',#3676,$,$); -#3679=IFCCLASSIFICATIONREFERENCE($,'23-21 19 11 15','Plastic Modular General Casework',#3676,$,$); -#3680=IFCCLASSIFICATIONREFERENCE($,'23-21 19 13','Custom General Casework',#3675,$,$); -#3681=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15','Specialty Casework',#3675,$,$); -#3682=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 11','Bank Specialty Casework',#3681,$,$); -#3683=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 13','Hospitality Specialty Casework',#3681,$,$); -#3684=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 15','Medical Specialty Casework',#3681,$,$); -#3685=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 15 11','Hospital Specialty Casework',#3684,$,$); -#3686=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 15 13','Nurse Station Specialty Casework',#3684,$,$); -#3687=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 15 15','Exam Room Specialty Casework',#3684,$,$); -#3688=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 15 17','Dental Specialty Casework',#3684,$,$); -#3689=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 15 19','Pharmacy Specialty Casework',#3684,$,$); -#3690=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 17','Display Specialty Casework',#3681,$,$); -#3691=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 19','Religious Specialty Casework',#3681,$,$); -#3692=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 21','Library Specialty Casework',#3681,$,$); -#3693=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 21 11','Library Specialty Casework Study Carrels',#3692,$,$); -#3694=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 21 13','Library Specialty Casework Book Stacks',#3692,$,$); -#3695=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 21 15','Library Specialty Casework Periodical Racks',#3692,$,$); -#3696=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 23','Educational Specialty Casework',#3681,$,$); -#3697=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 23 11','Educational Specialty Casework Study Carrels',#3696,$,$); -#3698=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 25','Laboratory Specialty Casework',#3681,$,$); -#3699=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 25 11','Metal Laboratory Specialty Casework',#3698,$,$); -#3700=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 25 13','Plastic-Laminate-Clad Laboratory Specialty Casework',#3698,$,$); -#3701=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 25 15','Wood Laboratory Specialty Casework',#3698,$,$); -#3702=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 25 17','Solid-Plastic Laboratory Specialty Casework',#3698,$,$); -#3703=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 27','Mortuary Specialty Casework',#3681,$,$); -#3704=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 29','Commercial Kitchen Specialty Casework',#3681,$,$); -#3705=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 31','Darkroom Specialty Casework',#3681,$,$); -#3706=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 33','Residential Specialty Casework',#3681,$,$); -#3707=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 33 11','Residential Kitchen Specialty Casework',#3706,$,$); -#3708=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 33 13','Residential Bathroom Specialty Casework',#3706,$,$); -#3709=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 33 15','Residential Dormitory Specialty Casework',#3706,$,$); -#3710=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 35','Utility Room Specialty Casework',#3681,$,$); -#3711=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 39','Mailroom Casework',#3681,$,$); -#3712=IFCCLASSIFICATIONREFERENCE($,'23-21 19 17','Casework Components',#3675,$,$); -#3713=IFCCLASSIFICATIONREFERENCE($,'23-21 19 17 11','Casework Component Cabinets',#3712,$,$); -#3714=IFCCLASSIFICATIONREFERENCE($,'23-21 19 17 13','Casework Component Hardware',#3712,$,$); -#3715=IFCCLASSIFICATIONREFERENCE($,'23-21 19 17 15','Casework Component Work Surfaces',#3712,$,$); -#3716=IFCCLASSIFICATIONREFERENCE($,'23-21 21 00','Food Service Equipment and Furnishings',#3626,$,$); -#3717=IFCCLASSIFICATIONREFERENCE($,'23-21 21 11','Commercial Food Services Cabinets',#3716,$,$); -#3718=IFCCLASSIFICATIONREFERENCE($,'23-21 21 11 11','Commercial Hot Cabinets',#3717,$,$); -#3719=IFCCLASSIFICATIONREFERENCE($,'23-21 21 11 13','Commercial Cold Cabinets',#3717,$,$); -#3720=IFCCLASSIFICATIONREFERENCE($,'23-21 21 11 15','Commercial Combination Hot Cold Cabinets',#3717,$,$); -#3721=IFCCLASSIFICATIONREFERENCE($,'23-21 21 11 17','Commercial Pastry Cabinets',#3717,$,$); -#3722=IFCCLASSIFICATIONREFERENCE($,'23-21 21 11 19','Commercial Warming Cabinets',#3717,$,$); -#3723=IFCCLASSIFICATIONREFERENCE($,'23-21 21 11 21','Commercial Snack Cabinets',#3717,$,$); -#3724=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13','Commercial Food Cooking Equipment',#3716,$,$); -#3725=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 11','Commercial Bain Maries',#3724,$,$); -#3726=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 13','Commercial Beverage Equipment',#3724,$,$); -#3727=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 13 11','Commercial Coffee Makers',#3726,$,$); -#3728=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 13 13','Commercial Coffee Warmers',#3726,$,$); -#3729=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 13 15','Commercial Iced Tea Makers',#3726,$,$); -#3730=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 15','Commercial Broilers',#3724,$,$); -#3731=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 15 11','Commercial Steam Broilers',#3730,$,$); -#3732=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 15 13','Commercial Infra Red Broilers',#3730,$,$); -#3733=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 15 15','Commercial Gas Broilers',#3730,$,$); -#3734=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 17','Commercial Food Cookers',#3724,$,$); -#3735=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 17 11','Commercial Food Induction Cookers',#3734,$,$); -#3736=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 17 13','Commercial Pasta Cookers',#3734,$,$); -#3737=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 17 15','Commercial Food Pressure Cookers',#3734,$,$); -#3738=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 17 17','Commercial Rice Cookers',#3734,$,$); -#3739=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 19','Commercial Crepe Machines',#3724,$,$); -#3740=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 21','Commercial Fryers',#3724,$,$); -#3741=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 21 11','Commercial Deep Fryers',#3740,$,$); -#3742=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 21 13','Commercial Pressure Fryers',#3740,$,$); -#3743=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 23','Commercial Frying Pans',#3724,$,$); -#3744=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 23 11','Commercial Tilting Frying Pans',#3743,$,$); -#3745=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 25','Commercial Griddles',#3724,$,$); -#3746=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 27','Commercial Grills',#3724,$,$); -#3747=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 27 11','Commercial Barbecue Grills',#3746,$,$); -#3748=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 27 13','Commercial Char Broiler Grills',#3746,$,$); -#3749=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 27 15','Commercial Hot Dog Grills',#3746,$,$); -#3750=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 29','Commercial Kettles',#3724,$,$); -#3751=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 29 11','Commercial Poacher Kettles',#3750,$,$); -#3752=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 29 13','Commercial Salmon Kettles',#3750,$,$); -#3753=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 31','Commercial Ovens',#3724,$,$); -#3754=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 31 11','Commercial Barbeque Ovens',#3753,$,$); -#3755=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 31 13','Commercial Combination Convection Ovens',#3753,$,$); -#3756=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 31 15','Commercial Convection Ovens',#3753,$,$); -#3757=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 31 17','Commercial Microwave Ovens',#3753,$,$); -#3758=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 31 19','Commercial Pastry Ovens',#3753,$,$); -#3759=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 31 21','Commercial Pizza Ovens',#3753,$,$); -#3760=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 31 23','Commercial Proofer Ovens',#3753,$,$); -#3761=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 31 25','Commercial Smoker Ovens',#3753,$,$); -#3762=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 33','Commercial Popcorn Machines',#3724,$,$); -#3763=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 35','Commercial Ranges',#3724,$,$); -#3764=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 37','Commercial Rotisseries',#3724,$,$); -#3765=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 39','Commercial Food Steamers',#3724,$,$); -#3766=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 39 11','Commercial High Pressure Food Steamer',#3765,$,$); -#3767=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 41','Commercial Skillets',#3724,$,$); -#3768=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 41 11','Commercial Tilt Skillets',#3767,$,$); -#3769=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 43','Commercial Stoves',#3724,$,$); -#3770=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 45','Commercial Toasters',#3724,$,$); -#3771=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 45 11','Commercial Toaster Conveyors',#3770,$,$); -#3772=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 47','Commercial Waffle Irons',#3724,$,$); -#3773=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 49','Commercial Small Specialized Cooking Equipment',#3724,$,$); -#3774=IFCCLASSIFICATIONREFERENCE($,'23-21 21 15','Commercial Food Services Warming Equipment',#3716,$,$); -#3775=IFCCLASSIFICATIONREFERENCE($,'23-21 21 15 11','Commercial Food Warmers',#3774,$,$); -#3776=IFCCLASSIFICATIONREFERENCE($,'23-21 21 15 13','Commercial Food Warmer Stations',#3774,$,$); -#3777=IFCCLASSIFICATIONREFERENCE($,'23-21 21 15 15','Commercial Hot Plates',#3774,$,$); -#3778=IFCCLASSIFICATIONREFERENCE($,'23-21 21 15 17','Commercial Steam Tables',#3774,$,$); -#3779=IFCCLASSIFICATIONREFERENCE($,'23-21 21 17','Commercial Food Services Cooling Equipment',#3716,$,$); -#3780=IFCCLASSIFICATIONREFERENCE($,'23-21 21 17 11','Commercial Refrigerated Tables',#3779,$,$); -#3781=IFCCLASSIFICATIONREFERENCE($,'23-21 21 19','Commercial Dishwasher Equipment',#3716,$,$); -#3782=IFCCLASSIFICATIONREFERENCE($,'23-21 21 19 11','Commercial Dishwashers',#3781,$,$); -#3783=IFCCLASSIFICATIONREFERENCE($,'23-21 21 19 11 11','Commercial Steam Dishwashers',#3782,$,$); -#3784=IFCCLASSIFICATIONREFERENCE($,'23-21 21 19 11 13','Commercial Dishwasher Conveyors',#3782,$,$); -#3785=IFCCLASSIFICATIONREFERENCE($,'23-21 21 19 11 15','Commercial Dishwasher Tray Conveyors',#3782,$,$); -#3786=IFCCLASSIFICATIONREFERENCE($,'23-21 21 21','Commercial Food Disposal Equipment',#3716,$,$); -#3787=IFCCLASSIFICATIONREFERENCE($,'23-21 21 21 11','Commercial Waste Disposal Units',#3786,$,$); -#3788=IFCCLASSIFICATIONREFERENCE($,'23-21 21 21 13','Commercial Garbage Disposals',#3786,$,$); -#3789=IFCCLASSIFICATIONREFERENCE($,'23-21 21 21 15','Commercial Garbage Pulpers',#3786,$,$); -#3790=IFCCLASSIFICATIONREFERENCE($,'23-21 21 23','Commercial Food Display Equipment',#3716,$,$); -#3791=IFCCLASSIFICATIONREFERENCE($,'23-21 21 23 11','Commercial Food Display Coolers',#3790,$,$); -#3792=IFCCLASSIFICATIONREFERENCE($,'23-21 21 23 11 11','Commercial Freezer Food Display Cases',#3791,$,$); -#3793=IFCCLASSIFICATIONREFERENCE($,'23-21 21 23 11 13','Commercial Heated Food Display Cases',#3791,$,$); -#3794=IFCCLASSIFICATIONREFERENCE($,'23-21 21 23 11 15','Commercial Refrigerated Food Display Cases',#3791,$,$); -#3795=IFCCLASSIFICATIONREFERENCE($,'23-21 21 23 11 17','Commercial Unconditioned Food Display Cases',#3791,$,$); -#3796=IFCCLASSIFICATIONREFERENCE($,'23-21 21 23 13','Commercial Food Guards',#3790,$,$); -#3797=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25','Commercial Food and Beverage Dispensing Equipment',#3716,$,$); -#3798=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 11','Commercial Soda Fountain Equipment',#3797,$,$); -#3799=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 13','Commercial Bottled Water Dispensers',#3797,$,$); -#3800=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 15','Commercial Bowl and Plate Dispensers',#3797,$,$); -#3801=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 17','Commercial Bread Dispensers',#3797,$,$); -#3802=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 19','Commercial Cappuccino or Espresso Dispensers',#3797,$,$); -#3803=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 21','Commercial Carbonated Beverage Dispensers',#3797,$,$); -#3804=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 23','Commercial Coffee Dispensers',#3797,$,$); -#3805=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 25','Commercial Condiment Dispensers',#3797,$,$); -#3806=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 27','Commercial Cream Dispensers',#3797,$,$); -#3807=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 29','Commercial Cup Dispensers',#3797,$,$); -#3808=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 31','Commercial Cup and Saucer Dispensers',#3797,$,$); -#3809=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 33','Commercial Bubbler Dispensers',#3797,$,$); -#3810=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 35','Commercial Drinking Glass Dispensers',#3797,$,$); -#3811=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 37','Commercial Flatware Dispensers',#3797,$,$); -#3812=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 39','Commercial Hot Chocolate Dispensers',#3797,$,$); -#3813=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 41','Commercial Hot Water Dispensers',#3797,$,$); -#3814=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 43','Commercial Ice Cream Dispensers',#3797,$,$); -#3815=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 45','Commercial Milk Dispensers',#3797,$,$); -#3816=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 47','Commercial Milkshake Dispensers',#3797,$,$); -#3817=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 49','Commercial Non Carbonated Beverage Dispensers',#3797,$,$); -#3818=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 49 11','Commercial Refrigerated Non Carbonated Beverage Dispensers',#3817,$,$); -#3819=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 51','Commercial Plate Dispensers',#3797,$,$); -#3820=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 53','Commercial Saucer Dispensers',#3797,$,$); -#3821=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 55','Commercial Slush Dispensers',#3797,$,$); -#3822=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 57','Commercial Soft Serve Ice Cream Dispensers',#3797,$,$); -#3823=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 59','Commercial Syrup Pump Dispensers',#3797,$,$); -#3824=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 61','Commercial Tray Dispensers',#3797,$,$); -#3825=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 63','Commercial Water Filter System',#3797,$,$); -#3826=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 65','Commercial Filtration Equipment',#3797,$,$); -#3827=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27','Commercial Refrigerators And Freezers',#3716,$,$); -#3828=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 11','Commercial Blast Chillers',#3827,$,$); -#3829=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 13','Commercial Freezers',#3827,$,$); -#3830=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 13 11','Commercial Blast Freezers',#3829,$,$); -#3831=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 13 13','Commercial Chest Freezers',#3829,$,$); -#3832=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 13 15','Commercial Flammable Liquid Freezers',#3829,$,$); -#3833=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 13 17','Commercial Freeze Drying Equipment',#3829,$,$); -#3834=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 13 19','Commercial Plate Freezers',#3829,$,$); -#3835=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 13 21','Commercial Sub Zero Freezers',#3829,$,$); -#3836=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 13 23','Commercial Upright Freezers',#3829,$,$); -#3837=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 13 25','Commercial Upright Reach In Freezers',#3829,$,$); -#3838=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 13 27','Commercial Upright Pass Through Freezers',#3829,$,$); -#3839=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 13 29','Commercial Upright Roll In Freezers',#3829,$,$); -#3840=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 13 31','Commercial Walk In Freezers',#3829,$,$); -#3841=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 15','Commercial Refrigerators',#3827,$,$); -#3842=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 15 11','Commercial Flammable Liquid Refrigerators',#3841,$,$); -#3843=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 15 13','Commercial Liquid Nitrogen Refrigerators',#3841,$,$); -#3844=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 15 15','Commercial Refrigerated Containers',#3841,$,$); -#3845=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 15 17','Commercial Refrigerated Tanks',#3841,$,$); -#3846=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 15 19','Commercial Refrigerated Vessels',#3841,$,$); -#3847=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 15 21','Commercial Upright Refrigerators',#3841,$,$); -#3848=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 15 23','Commercial Upright Reach In Refrigerators',#3841,$,$); -#3849=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 15 25','Commercial Upright Pass Through Refrigerators',#3841,$,$); -#3850=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 15 27','Commercial Upright Roll In Refrigerators',#3841,$,$); -#3851=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 15 29','Commercial Walk In Refrigerators',#3841,$,$); -#3852=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 17','Commercial Refrigerator Freezers',#3827,$,$); -#3853=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 19','Commercial Food Storage Coolers',#3827,$,$); -#3854=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 19 11','Commercial Walk In Coolers',#3853,$,$); -#3855=IFCCLASSIFICATIONREFERENCE($,'23-21 21 29','Commercial Ice Machines',#3716,$,$); -#3856=IFCCLASSIFICATIONREFERENCE($,'23-21 21 29 11','Commercial Block Ice Makers',#3855,$,$); -#3857=IFCCLASSIFICATIONREFERENCE($,'23-21 21 29 13','Commercial Cube Ice Makers',#3855,$,$); -#3858=IFCCLASSIFICATIONREFERENCE($,'23-21 21 29 15','Commercial Flaker Ice Makers',#3855,$,$); -#3859=IFCCLASSIFICATIONREFERENCE($,'23-21 21 29 17','Commercial Ice Dispensers',#3855,$,$); -#3860=IFCCLASSIFICATIONREFERENCE($,'23-21 21 29 19','Commercial Ice Shaver Dispensers',#3855,$,$); -#3861=IFCCLASSIFICATIONREFERENCE($,'23-21 21 29 21','Commercial Ice Maker Bins',#3855,$,$); -#3862=IFCCLASSIFICATIONREFERENCE($,'23-21 21 31','Commercial Food Preparation Equipment',#3716,$,$); -#3863=IFCCLASSIFICATIONREFERENCE($,'23-21 21 31 11','Commercial Food Mixers',#3862,$,$); -#3864=IFCCLASSIFICATIONREFERENCE($,'23-21 21 31 13','Commercial Food Peelers',#3862,$,$); -#3865=IFCCLASSIFICATIONREFERENCE($,'23-21 21 31 15','Commercial Food Processors',#3862,$,$); -#3866=IFCCLASSIFICATIONREFERENCE($,'23-21 21 31 17','Commercial Food Service Stations',#3862,$,$); -#3867=IFCCLASSIFICATIONREFERENCE($,'23-21 21 31 19','Commercial Food Slicers',#3862,$,$); -#3868=IFCCLASSIFICATIONREFERENCE($,'23-21 21 31 19 11','Commercial Electric Food Slicers',#3867,$,$); -#3869=IFCCLASSIFICATIONREFERENCE($,'23-21 21 31 19 13','Commercial Mechanical Food Slicers',#3867,$,$); -#3870=IFCCLASSIFICATIONREFERENCE($,'23-21 21 31 21','Commercial Food Preparation Tables',#3862,$,$); -#3871=IFCCLASSIFICATIONREFERENCE($,'23-21 21 31 21 11','Commercial Refrigerated Food Preparation Tables',#3870,$,$); -#3872=IFCCLASSIFICATIONREFERENCE($,'23-21 21 31 23','Commercial Drink Making Equipment',#3862,$,$); -#3873=IFCCLASSIFICATIONREFERENCE($,'23-21 21 33','Commercial Food Service Furniture',#3716,$,$); -#3874=IFCCLASSIFICATIONREFERENCE($,'23-21 21 33 11','Commercial Bar Stools',#3873,$,$); -#3875=IFCCLASSIFICATIONREFERENCE($,'23-21 21 33 13','Commercial Restaurant Chairs',#3873,$,$); -#3876=IFCCLASSIFICATIONREFERENCE($,'23-21 21 33 15','Commercial Restaurant Booths',#3873,$,$); -#3877=IFCCLASSIFICATIONREFERENCE($,'23-21 21 33 17','Commercial Restaurant Seating Units',#3873,$,$); -#3878=IFCCLASSIFICATIONREFERENCE($,'23-21 21 33 19','Commercial Restaurant Tables',#3873,$,$); -#3879=IFCCLASSIFICATIONREFERENCE($,'23-21 21 35','Commercial Serving Counters',#3716,$,$); -#3880=IFCCLASSIFICATIONREFERENCE($,'23-21 21 35 11','Commercial Bars',#3879,$,$); -#3881=IFCCLASSIFICATIONREFERENCE($,'23-21 21 35 11 11','Commercial Beverage Bars',#3880,$,$); -#3882=IFCCLASSIFICATIONREFERENCE($,'23-21 21 35 11 13','Commercial Salad Bars',#3880,$,$); -#3883=IFCCLASSIFICATIONREFERENCE($,'23-21 21 35 11 15','Commercial Bar Equipment',#3880,$,$); -#3884=IFCCLASSIFICATIONREFERENCE($,'23-21 21 35 13','Commercial Serving Counters',#3879,$,$); -#3885=IFCCLASSIFICATIONREFERENCE($,'23-21 21 35 13 11','Commercial Condiment Counters',#3884,$,$); -#3886=IFCCLASSIFICATIONREFERENCE($,'23-21 21 35 13 13','Commercial Serving Counters',#3884,$,$); -#3887=IFCCLASSIFICATIONREFERENCE($,'23-21 21 35 15','Commercial Service Line Equipment',#3879,$,$); -#3888=IFCCLASSIFICATIONREFERENCE($,'23-21 21 37','Commercial Food Service Storage Equipment',#3716,$,$); -#3889=IFCCLASSIFICATIONREFERENCE($,'23-21 21 37 11','Commercial Bottle Racks',#3888,$,$); -#3890=IFCCLASSIFICATIONREFERENCE($,'23-21 21 39','Commercial Food Service Delivery Equipment',#3716,$,$); -#3891=IFCCLASSIFICATIONREFERENCE($,'23-21 21 39 11','Commercial Food Delivery Conveyors',#3890,$,$); -#3892=IFCCLASSIFICATIONREFERENCE($,'23-21 21 39 13','Commercial Food Delivery Carts',#3890,$,$); -#3893=IFCCLASSIFICATIONREFERENCE($,'23-21 21 39 15','Commercial Restaurant Turntables',#3890,$,$); -#3894=IFCCLASSIFICATIONREFERENCE($,'23-21 21 41','Commercial Food Service Ventilation Equipment',#3716,$,$); -#3895=IFCCLASSIFICATIONREFERENCE($,'23-21 21 41 11','Commercial Food Hood Equipment',#3894,$,$); -#3896=IFCCLASSIFICATIONREFERENCE($,'23-21 21 41 11 11','Commercial Food Service Hoods',#3895,$,$); -#3897=IFCCLASSIFICATIONREFERENCE($,'23-21 21 41 13','Commercial Food Ventilation Equipment',#3894,$,$); -#3898=IFCCLASSIFICATIONREFERENCE($,'23-21 21 41 13 11','Commercial Food Ventilation Fire Suppression Systems',#3897,$,$); -#3899=IFCCLASSIFICATIONREFERENCE($,'23-21 21 41 13 13','Commercial Catering Ventilation',#3897,$,$); -#3900=IFCCLASSIFICATIONREFERENCE($,'23-21 21 43','Commercial Food Processing Equipment',#3716,$,$); -#3901=IFCCLASSIFICATIONREFERENCE($,'23-21 21 45','Commercial Food Weighing Equipment',#3716,$,$); -#3902=IFCCLASSIFICATIONREFERENCE($,'23-21 21 47','Commercial Food Wrapping Equipment',#3716,$,$); -#3903=IFCCLASSIFICATIONREFERENCE($,'23-21 23 00','Residential Furniture and Equipment',#3626,$,$); -#3904=IFCCLASSIFICATIONREFERENCE($,'23-21 23 11','Complete Residential Dining Room Suites',#3903,$,$); -#3905=IFCCLASSIFICATIONREFERENCE($,'23-21 23 13','Residential Seating',#3903,$,$); -#3906=IFCCLASSIFICATIONREFERENCE($,'23-21 23 13 11','Residential Chairs',#3905,$,$); -#3907=IFCCLASSIFICATIONREFERENCE($,'23-21 23 13 13','Residential Settees',#3905,$,$); -#3908=IFCCLASSIFICATIONREFERENCE($,'23-21 23 13 15','Residential Sofas',#3905,$,$); -#3909=IFCCLASSIFICATIONREFERENCE($,'23-21 23 13 17','Residential Stools',#3905,$,$); -#3910=IFCCLASSIFICATIONREFERENCE($,'23-21 23 13 19','Residential Benches',#3905,$,$); -#3911=IFCCLASSIFICATIONREFERENCE($,'23-21 23 13 21','Residential Chaises Lounges',#3905,$,$); -#3912=IFCCLASSIFICATIONREFERENCE($,'23-21 23 13 23','Residential Sofa Beds',#3905,$,$); -#3913=IFCCLASSIFICATIONREFERENCE($,'23-21 23 13 25','Residential Chair Beds',#3905,$,$); -#3914=IFCCLASSIFICATIONREFERENCE($,'23-21 23 15','Residential Tables',#3903,$,$); -#3915=IFCCLASSIFICATIONREFERENCE($,'23-21 23 15 11','Residential Dining Room Tables',#3914,$,$); -#3916=IFCCLASSIFICATIONREFERENCE($,'23-21 23 15 13','Residential Sideboards',#3914,$,$); -#3917=IFCCLASSIFICATIONREFERENCE($,'23-21 23 15 15','Residential End Tables',#3914,$,$); -#3918=IFCCLASSIFICATIONREFERENCE($,'23-21 23 15 17','Residential Coffee Tables',#3914,$,$); -#3919=IFCCLASSIFICATIONREFERENCE($,'23-21 23 17','Residential Storage Units',#3903,$,$); -#3920=IFCCLASSIFICATIONREFERENCE($,'23-21 23 17 11','Residential Cabinet',#3919,$,$); -#3921=IFCCLASSIFICATIONREFERENCE($,'23-21 23 17 13','Residential China Cabinets',#3919,$,$); -#3922=IFCCLASSIFICATIONREFERENCE($,'23-21 23 17 15','Residential Cupboards',#3919,$,$); -#3923=IFCCLASSIFICATIONREFERENCE($,'23-21 23 17 17','Residential Chests',#3919,$,$); -#3924=IFCCLASSIFICATIONREFERENCE($,'23-21 23 19','Residential Bedroom Furniture',#3903,$,$); -#3925=IFCCLASSIFICATIONREFERENCE($,'23-21 23 19 11','Complete Residential Bedroom Suites',#3924,$,$); -#3926=IFCCLASSIFICATIONREFERENCE($,'23-21 23 19 13','Residential Beds',#3924,$,$); -#3927=IFCCLASSIFICATIONREFERENCE($,'23-21 23 19 13 11','Residential Headboards',#3926,$,$); -#3928=IFCCLASSIFICATIONREFERENCE($,'23-21 23 19 13 13','Residential Footboards',#3926,$,$); -#3929=IFCCLASSIFICATIONREFERENCE($,'23-21 23 19 13 15','Residential Cots',#3926,$,$); -#3930=IFCCLASSIFICATIONREFERENCE($,'23-21 23 19 13 17','Residential Mattresses',#3926,$,$); -#3931=IFCCLASSIFICATIONREFERENCE($,'23-21 23 19 15','Residential Bedside Units',#3924,$,$); -#3932=IFCCLASSIFICATIONREFERENCE($,'23-21 23 19 17','Residential Dressing Tables',#3924,$,$); -#3933=IFCCLASSIFICATIONREFERENCE($,'23-21 23 19 19','Residential Dressers',#3924,$,$); -#3934=IFCCLASSIFICATIONREFERENCE($,'23-21 23 21','Residential Food Cabinets',#3903,$,$); -#3935=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23','Residential Food Cooking Equipment',#3903,$,$); -#3936=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 11','Residential Broilers',#3935,$,$); -#3937=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 11 11','Residential Steam Broilers',#3936,$,$); -#3938=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 11 13','Residential Infra Red Broilers',#3936,$,$); -#3939=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 11 15','Residential Gas Broilers',#3936,$,$); -#3940=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 13','Residential Food Cookers',#3935,$,$); -#3941=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 13 11','Residential Food Induction Cookers',#3940,$,$); -#3942=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 13 13','Residential Pasta Cookers',#3940,$,$); -#3943=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 13 15','Residential Food Pressure Cookers',#3940,$,$); -#3944=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 13 17','Residential Rice Cookers',#3940,$,$); -#3945=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 15','Residential Crepe Machines',#3935,$,$); -#3946=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 17','Residential Fryers',#3935,$,$); -#3947=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 17 11','Residential Deep Fryers',#3946,$,$); -#3948=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 17 13','Residential Pressure Fryers',#3946,$,$); -#3949=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 19','Residential Griddles',#3935,$,$); -#3950=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 21','Residential Grills',#3935,$,$); -#3951=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 21 11','Residential Barbecue Grills',#3950,$,$); -#3952=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 21 13','Residential Char Broiler Grills',#3950,$,$); -#3953=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 21 15','Residential Hot Dog Grills',#3950,$,$); -#3954=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 23','Residential Kettles',#3935,$,$); -#3955=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 23 11','Residential Poacher Kettles',#3954,$,$); -#3956=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 23 13','Residential Salmon Kettles',#3954,$,$); -#3957=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 25','Residential Ovens and Stoves',#3935,$,$); -#3958=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 25 11','Residential Stoves',#3957,$,$); -#3959=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 25 13','Residential Combination Convection Ovens',#3957,$,$); -#3960=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 25 15','Residential Convection Ovens',#3957,$,$); -#3961=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 25 17','Residential Gas Ovens',#3957,$,$); -#3962=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 25 19','Residential Electric Ovens',#3957,$,$); -#3963=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 25 21','Residential Microwave Ovens',#3957,$,$); -#3964=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 27','Residential Rotisseries',#3935,$,$); -#3965=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 29','Residential Food Steamers',#3935,$,$); -#3966=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 29 11','Residential High Pressure Food Steamer',#3965,$,$); -#3967=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 31','Residential Small Specialized Cooking Equipment',#3935,$,$); -#3968=IFCCLASSIFICATIONREFERENCE($,'23-21 23 25','Residential Dishwashers',#3903,$,$); -#3969=IFCCLASSIFICATIONREFERENCE($,'23-21 23 25 11','Residential Electric Dishwashers',#3968,$,$); -#3970=IFCCLASSIFICATIONREFERENCE($,'23-21 23 25 13','Residential Gas Dishwashers',#3968,$,$); -#3971=IFCCLASSIFICATIONREFERENCE($,'23-21 23 27','Residential Waste Disposal Units',#3903,$,$); -#3972=IFCCLASSIFICATIONREFERENCE($,'23-21 23 27 11','Residential Garbage Disposals',#3971,$,$); -#3973=IFCCLASSIFICATIONREFERENCE($,'23-21 23 27 13','Residential Garbage Compactors',#3971,$,$); -#3974=IFCCLASSIFICATIONREFERENCE($,'23-21 23 27 13 11','Residential Coffee Dispensers',#3973,$,$); -#3975=IFCCLASSIFICATIONREFERENCE($,'23-21 23 29','Residential Food and Beverage Dispensing Equipment',#3903,$,$); -#3976=IFCCLASSIFICATIONREFERENCE($,'23-21 23 29 11','Residential Cappuccino or Espresso Dispensers',#3975,$,$); -#3977=IFCCLASSIFICATIONREFERENCE($,'23-21 23 29 13','Residential Bubbler Dispensers',#3975,$,$); -#3978=IFCCLASSIFICATIONREFERENCE($,'23-21 23 29 15','Residential Hot Water Dispensers',#3975,$,$); -#3979=IFCCLASSIFICATIONREFERENCE($,'23-21 23 31','Residential Water Filter System',#3903,$,$); -#3980=IFCCLASSIFICATIONREFERENCE($,'23-21 23 33','Residential Refrigerators And Freezers',#3903,$,$); -#3981=IFCCLASSIFICATIONREFERENCE($,'23-21 23 33 11','Residential Freezers',#3980,$,$); -#3982=IFCCLASSIFICATIONREFERENCE($,'23-21 23 33 11 11','Residential Chest Freezers',#3981,$,$); -#3983=IFCCLASSIFICATIONREFERENCE($,'23-21 23 33 11 13','Residential Sub Zero Freezers',#3981,$,$); -#3984=IFCCLASSIFICATIONREFERENCE($,'23-21 23 33 11 15','Residential Upright Freezers',#3981,$,$); -#3985=IFCCLASSIFICATIONREFERENCE($,'23-21 23 33 13','Residential Refrigerators',#3980,$,$); -#3986=IFCCLASSIFICATIONREFERENCE($,'23-21 23 33 13 11','Residential Upright Refrigerators',#3985,$,$); -#3987=IFCCLASSIFICATIONREFERENCE($,'23-21 23 33 15','Residential Refrigerator Freezers',#3980,$,$); -#3988=IFCCLASSIFICATIONREFERENCE($,'23-21 23 35','Residential Ice Machines',#3903,$,$); -#3989=IFCCLASSIFICATIONREFERENCE($,'23-21 23 35 11','Residential Cube Ice Makers',#3988,$,$); -#3990=IFCCLASSIFICATIONREFERENCE($,'23-21 23 35 13','Residential Ice Dispensers',#3988,$,$); -#3991=IFCCLASSIFICATIONREFERENCE($,'23-21 23 37','Residential Food Preparation Equipment',#3903,$,$); -#3992=IFCCLASSIFICATIONREFERENCE($,'23-21 23 37 11','Residential Food Mixers',#3991,$,$); -#3993=IFCCLASSIFICATIONREFERENCE($,'23-21 23 37 13','Residential Food Peelers',#3991,$,$); -#3994=IFCCLASSIFICATIONREFERENCE($,'23-21 23 37 15','Residential Food Processors',#3991,$,$); -#3995=IFCCLASSIFICATIONREFERENCE($,'23-21 23 37 17','Residential Food Slicers',#3991,$,$); -#3996=IFCCLASSIFICATIONREFERENCE($,'23-21 23 37 17 11','Residential Electric Food Slicers',#3995,$,$); -#3997=IFCCLASSIFICATIONREFERENCE($,'23-21 23 37 17 13','Residential Mechanical Food Slicers',#3995,$,$); -#3998=IFCCLASSIFICATIONREFERENCE($,'23-21 23 37 19','Residential Food Preparation Tables',#3991,$,$); -#3999=IFCCLASSIFICATIONREFERENCE($,'23-21 23 39','Residential Kitchen and Dining Room Furniture',#3903,$,$); -#4000=IFCCLASSIFICATIONREFERENCE($,'23-21 23 39 11','Residential Bar Stools',#3999,$,$); -#4001=IFCCLASSIFICATIONREFERENCE($,'23-21 23 39 13','Residential Kitchen and Dining Room Chairs',#3999,$,$); -#4002=IFCCLASSIFICATIONREFERENCE($,'23-21 23 39 15','Residential Kitchen and Dining Room Tables',#3999,$,$); -#4003=IFCCLASSIFICATIONREFERENCE($,'23-21 23 39 17','Residential Bars',#3999,$,$); -#4004=IFCCLASSIFICATIONREFERENCE($,'23-21 23 39 17 11','Residential Beverage Bars',#4003,$,$); -#4005=IFCCLASSIFICATIONREFERENCE($,'23-21 23 39 17 13','Residential Bar Equipment',#4003,$,$); -#4006=IFCCLASSIFICATIONREFERENCE($,'23-21 23 41','Residential Food Storage Equipment',#3903,$,$); -#4007=IFCCLASSIFICATIONREFERENCE($,'23-21 23 41 11','Residential Bottle Racks',#4006,$,$); -#4008=IFCCLASSIFICATIONREFERENCE($,'23-21 23 43','Residential Cooking Ventilation Equipment',#3903,$,$); -#4009=IFCCLASSIFICATIONREFERENCE($,'23-21 23 43 11','Residential Range Hoods',#4008,$,$); -#4010=IFCCLASSIFICATIONREFERENCE($,'23-21 23 43 13','Residential Food Ventilation Equipment',#4008,$,$); -#4011=IFCCLASSIFICATIONREFERENCE($,'23-21 23 45','Residential Clothes Airers',#3903,$,$); -#4012=IFCCLASSIFICATIONREFERENCE($,'23-21 23 45 11','Residential Clothes Stands',#4011,$,$); -#4013=IFCCLASSIFICATIONREFERENCE($,'23-21 23 45 13','Residential Clothes Lines',#4011,$,$); -#4014=IFCCLASSIFICATIONREFERENCE($,'23-21 23 47','Residential Combination Laundry Washer Dryers',#3903,$,$); -#4015=IFCCLASSIFICATIONREFERENCE($,'23-21 23 49','Residential Ironing and Pressing Machines',#3903,$,$); -#4016=IFCCLASSIFICATIONREFERENCE($,'23-21 23 51','Residential Laundry Dryers',#3903,$,$); -#4017=IFCCLASSIFICATIONREFERENCE($,'23-21 23 51 11','Residential Electric Laundry Dryers',#4016,$,$); -#4018=IFCCLASSIFICATIONREFERENCE($,'23-21 23 51 13','Residential Gas Laundry Dryers',#4016,$,$); -#4019=IFCCLASSIFICATIONREFERENCE($,'23-21 23 53','Residential Washing Machines',#3903,$,$); -#4020=IFCCLASSIFICATIONREFERENCE($,'23-21 23 53 11','Residential Front Loading Laundry Washers',#4019,$,$); -#4021=IFCCLASSIFICATIONREFERENCE($,'23-21 23 53 13','Residential Side Loading Laundry Washers',#4019,$,$); -#4022=IFCCLASSIFICATIONREFERENCE($,'23-21 23 53 15','Residential Top Loading Laundry Washers',#4019,$,$); -#4023=IFCCLASSIFICATIONREFERENCE($,'23-21 25 00','Educational and Cultural Equipment and Furnishings',#3626,$,$); -#4024=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11','Group Seating',#4023,$,$); -#4025=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 11','Auditorium Seating',#4024,$,$); -#4026=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 11 11','Fixed Audience Seating',#4025,$,$); -#4027=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 11 13','Portable Audience Seating',#4025,$,$); -#4028=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 11 13 11','Folding Audience Chairs',#4027,$,$); -#4029=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 11 13 13','Interlocking Audience Chairs',#4027,$,$); -#4030=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 11 13 15','Stacking Audience Chairs',#4027,$,$); -#4031=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 13','Classroom Furniture',#4024,$,$); -#4032=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 13 11','Seat Assembly',#4031,$,$); -#4033=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 13 13','Table Assembly',#4031,$,$); -#4034=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 13 15','Modular Desks',#4031,$,$); -#4035=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 15','Multiple Use Fixed Seating',#4024,$,$); -#4036=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 17','Platforms',#4024,$,$); -#4037=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 17 11','Portable Stages',#4036,$,$); -#4038=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 17 13','Risers',#4036,$,$); -#4039=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 19','Language Laboratory Equipment',#4024,$,$); -#4040=IFCCLASSIFICATIONREFERENCE($,'23-21 25 13','Theater and Stage Equipment',#4023,$,$); -#4041=IFCCLASSIFICATIONREFERENCE($,'23-21 25 13 11','Acoustical Shells',#4040,$,$); -#4042=IFCCLASSIFICATIONREFERENCE($,'23-21 25 13 13','Rigging Systems and Controls',#4040,$,$); -#4043=IFCCLASSIFICATIONREFERENCE($,'23-21 25 13 15','Scenery Docks',#4040,$,$); -#4044=IFCCLASSIFICATIONREFERENCE($,'23-21 25 13 17','Suspension Systems',#4040,$,$); -#4045=IFCCLASSIFICATIONREFERENCE($,'23-21 25 13 19','Stage Curtains',#4040,$,$); -#4046=IFCCLASSIFICATIONREFERENCE($,'23-21 25 15','Planetarium Equipment and Furnishings',#4023,$,$); -#4047=IFCCLASSIFICATIONREFERENCE($,'23-21 25 15 11','Planetarium Projectors',#4046,$,$); -#4048=IFCCLASSIFICATIONREFERENCE($,'23-21 25 15 13','Planetarium Seating',#4046,$,$); -#4049=IFCCLASSIFICATIONREFERENCE($,'23-21 25 17','Observatory Equipment and Furnishings',#4023,$,$); -#4050=IFCCLASSIFICATIONREFERENCE($,'23-21 25 17 11','Telescopes',#4049,$,$); -#4051=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19','Ecclesiastical Equipment and Furnishings',#4023,$,$); -#4052=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 11','Religious Seating',#4051,$,$); -#4053=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 11 11','Pews',#4052,$,$); -#4054=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 11 13','Benches',#4052,$,$); -#4055=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 13','Chancel Furnishings',#4051,$,$); -#4056=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 13 11','Lecterns',#4055,$,$); -#4057=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 13 13','Pulpits',#4055,$,$); -#4058=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 13 15','Choir Screens',#4055,$,$); -#4059=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 13 17','Altars',#4055,$,$); -#4060=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 15','Baptisteries',#4051,$,$); -#4061=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 17','Baptismal Fonts',#4051,$,$); -#4062=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 19','Instrumental Equipment',#4051,$,$); -#4063=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 19 11','Organs',#4062,$,$); -#4064=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 19 13','Organ Cases',#4062,$,$); -#4065=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 19 15','Screens',#4062,$,$); -#4066=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 19 17','Bells',#4062,$,$); -#4067=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 19 19','Carillons',#4062,$,$); -#4068=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 21','Synagogue Furniture',#4051,$,$); -#4069=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 23','Mosque Furniture',#4051,$,$); -#4070=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 25','Temple Furniture',#4051,$,$); -#4071=IFCCLASSIFICATIONREFERENCE($,'23-21 25 21','Library and Archive Equipment and Furnishings',#4023,$,$); -#4072=IFCCLASSIFICATIONREFERENCE($,'23-21 25 21 11','Library Stack Systems',#4071,$,$); -#4073=IFCCLASSIFICATIONREFERENCE($,'23-21 25 21 11 11','Library Shelving',#4072,$,$); -#4074=IFCCLASSIFICATIONREFERENCE($,'23-21 25 21 13','Book Depositories',#4071,$,$); -#4075=IFCCLASSIFICATIONREFERENCE($,'23-21 25 21 15','Book Theft Protection Equipment',#4071,$,$); -#4076=IFCCLASSIFICATIONREFERENCE($,'23-21 25 21 17','Library Furniture',#4071,$,$); -#4077=IFCCLASSIFICATIONREFERENCE($,'23-21 25 21 17 11','Library Filing Furniture',#4076,$,$); -#4078=IFCCLASSIFICATIONREFERENCE($,'23-21 25 21 17 13','Library Display Furniture',#4076,$,$); -#4079=IFCCLASSIFICATIONREFERENCE($,'23-21 25 21 17 15','Study Carrels',#4076,$,$); -#4080=IFCCLASSIFICATIONREFERENCE($,'23-21 25 23','Exhibition Equipment and Furnishings',#4023,$,$); -#4081=IFCCLASSIFICATIONREFERENCE($,'23-21 25 23 11','Display Furniture',#4080,$,$); -#4082=IFCCLASSIFICATIONREFERENCE($,'23-21 25 23 11 11','Display Cabinets',#4081,$,$); -#4083=IFCCLASSIFICATIONREFERENCE($,'23-21 25 23 11 13','Display Racks',#4081,$,$); -#4084=IFCCLASSIFICATIONREFERENCE($,'23-21 25 23 11 15','Display Carousels',#4081,$,$); -#4085=IFCCLASSIFICATIONREFERENCE($,'23-21 25 23 13','Gallery Hanging Systems',#4080,$,$); -#4086=IFCCLASSIFICATIONREFERENCE($,'23-21 25 23 15','Pedestals',#4080,$,$); -#4087=IFCCLASSIFICATIONREFERENCE($,'23-21 25 23 17','Retail Cabinets',#4080,$,$); -#4088=IFCCLASSIFICATIONREFERENCE($,'23-21 25 23 19','Exhibition Stands',#4080,$,$); -#4089=IFCCLASSIFICATIONREFERENCE($,'23-21 25 23 21','Shell Schemes',#4080,$,$); -#4090=IFCCLASSIFICATIONREFERENCE($,'23-21 25 23 23','Exhibit Equipment',#4080,$,$); -#4091=IFCCLASSIFICATIONREFERENCE($,'23-21 27 00','Child Furnishings',#3626,$,$); -#4092=IFCCLASSIFICATIONREFERENCE($,'23-21 27 11','Child Beds',#4091,$,$); -#4093=IFCCLASSIFICATIONREFERENCE($,'23-21 27 11 11','Infant Cradles',#4092,$,$); -#4094=IFCCLASSIFICATIONREFERENCE($,'23-21 27 11 13','Bassinets',#4092,$,$); -#4095=IFCCLASSIFICATIONREFERENCE($,'23-21 27 11 15','Infant Beds',#4092,$,$); -#4096=IFCCLASSIFICATIONREFERENCE($,'23-21 27 11 17','Toddler Beds',#4092,$,$); -#4097=IFCCLASSIFICATIONREFERENCE($,'23-21 27 11 19','Children Beds',#4092,$,$); -#4098=IFCCLASSIFICATIONREFERENCE($,'23-21 27 13','Child Cots',#4091,$,$); -#4099=IFCCLASSIFICATIONREFERENCE($,'23-21 27 13 11','Toddler Cots',#4098,$,$); -#4100=IFCCLASSIFICATIONREFERENCE($,'23-21 27 13 13','Children Cots',#4098,$,$); -#4101=IFCCLASSIFICATIONREFERENCE($,'23-21 27 13 15','Cot Carrier',#4098,$,$); -#4102=IFCCLASSIFICATIONREFERENCE($,'23-21 27 15','Child Playpens',#4091,$,$); -#4103=IFCCLASSIFICATIONREFERENCE($,'23-21 27 17','Child Benches',#4091,$,$); -#4104=IFCCLASSIFICATIONREFERENCE($,'23-21 27 17 11','Toddler Benches',#4103,$,$); -#4105=IFCCLASSIFICATIONREFERENCE($,'23-21 27 17 13','Children Benches',#4103,$,$); -#4106=IFCCLASSIFICATIONREFERENCE($,'23-21 27 19','Child Bathtub',#4091,$,$); -#4107=IFCCLASSIFICATIONREFERENCE($,'23-21 27 19 11','Infant Bathtubs',#4106,$,$); -#4108=IFCCLASSIFICATIONREFERENCE($,'23-21 27 19 13','Toddler Bathtubs',#4106,$,$); -#4109=IFCCLASSIFICATIONREFERENCE($,'23-21 27 19 15','Children Bathtubs',#4106,$,$); -#4110=IFCCLASSIFICATIONREFERENCE($,'23-21 27 21','Child Chairs',#4091,$,$); -#4111=IFCCLASSIFICATIONREFERENCE($,'23-21 27 21 11','Child High Chairs',#4110,$,$); -#4112=IFCCLASSIFICATIONREFERENCE($,'23-21 27 21 13','Child Stools',#4110,$,$); -#4113=IFCCLASSIFICATIONREFERENCE($,'23-21 27 23','Child Play Panels',#4091,$,$); -#4114=IFCCLASSIFICATIONREFERENCE($,'23-21 27 25','Child Indoor Swings',#4091,$,$); -#4115=IFCCLASSIFICATIONREFERENCE($,'23-21 27 25 11','Infant Swings',#4114,$,$); -#4116=IFCCLASSIFICATIONREFERENCE($,'23-21 27 25 13','Toddler Swings',#4114,$,$); -#4117=IFCCLASSIFICATIONREFERENCE($,'23-21 27 27','Child Sofas',#4091,$,$); -#4118=IFCCLASSIFICATIONREFERENCE($,'23-21 27 29','Child Strollers',#4091,$,$); -#4119=IFCCLASSIFICATIONREFERENCE($,'23-21 27 29 11','Child Carriage Strollers',#4118,$,$); -#4120=IFCCLASSIFICATIONREFERENCE($,'23-21 27 29 13','Child Multiple Carriage Strollers',#4118,$,$); -#4121=IFCCLASSIFICATIONREFERENCE($,'23-21 27 29 15','Child Perambulators',#4118,$,$); -#4122=IFCCLASSIFICATIONREFERENCE($,'23-21 27 29 17','Child Buggies',#4118,$,$); -#4123=IFCCLASSIFICATIONREFERENCE($,'23-21 27 31','Child Tables',#4091,$,$); -#4124=IFCCLASSIFICATIONREFERENCE($,'23-21 27 31 11','Diaper Changing Tables',#4123,$,$); -#4125=IFCCLASSIFICATIONREFERENCE($,'23-21 27 33','Child Storage Units',#4091,$,$); -#4126=IFCCLASSIFICATIONREFERENCE($,'23-21 27 33 11','Child File Cabinets',#4125,$,$); -#4127=IFCCLASSIFICATIONREFERENCE($,'23-21 27 33 13','Child Kiosks',#4125,$,$); -#4128=IFCCLASSIFICATIONREFERENCE($,'23-21 27 33 15','Child Shelves',#4125,$,$); -#4129=IFCCLASSIFICATIONREFERENCE($,'23-21 27 33 17','Child Book Display Units',#4125,$,$); -#4130=IFCCLASSIFICATIONREFERENCE($,'23-21 27 33 19','Child Card Catalog Units',#4125,$,$); -#4131=IFCCLASSIFICATIONREFERENCE($,'23-21 27 33 21','Child Cubbies',#4125,$,$); -#4132=IFCCLASSIFICATIONREFERENCE($,'23-21 27 35','Child Dressers',#4091,$,$); -#4133=IFCCLASSIFICATIONREFERENCE($,'23-21 29 00','Athletic and Recreational Equipment',#3626,$,$); -#4134=IFCCLASSIFICATIONREFERENCE($,'23-21 29 11','Athletic or Recreation Screening',#4133,$,$); -#4135=IFCCLASSIFICATIONREFERENCE($,'23-21 29 11 11','Tennis Court Windbreakers',#4134,$,$); -#4136=IFCCLASSIFICATIONREFERENCE($,'23-21 29 13','Athletic Surfacing',#4133,$,$); -#4137=IFCCLASSIFICATIONREFERENCE($,'23-21 29 13 11','Baseball Field Surfacing',#4136,$,$); -#4138=IFCCLASSIFICATIONREFERENCE($,'23-21 29 13 13','Multi Purpose Court Surfacing',#4136,$,$); -#4139=IFCCLASSIFICATIONREFERENCE($,'23-21 29 13 15','Resilient Matting',#4136,$,$); -#4140=IFCCLASSIFICATIONREFERENCE($,'23-21 29 13 17','Synthetic Grass Surfacing',#4136,$,$); -#4141=IFCCLASSIFICATIONREFERENCE($,'23-21 29 13 19','Synthetic Running Track Surfacing',#4136,$,$); -#4142=IFCCLASSIFICATIONREFERENCE($,'23-21 29 13 21','Tennis Court Surfacing',#4136,$,$); -#4143=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15','Athletic Equipment',#4133,$,$); -#4144=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 11','Bowling Alley Equipment',#4143,$,$); -#4145=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 13','Goalposts',#4143,$,$); -#4146=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 15','Nets',#4143,$,$); -#4147=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 17','Backstops',#4143,$,$); -#4148=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 19','Scoreboards',#4143,$,$); -#4149=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 21','Time Clocks',#4143,$,$); -#4150=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 23','Floor Sockets',#4143,$,$); -#4151=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 25','Climbing Equipment',#4143,$,$); -#4152=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 25 11','Climbing Walls',#4151,$,$); -#4153=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 25 13','Climbing Ropes',#4151,$,$); -#4154=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 27','Gymnasium Dividers',#4143,$,$); -#4155=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 29','Wall Mats',#4143,$,$); -#4156=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 31','Floor Mats',#4143,$,$); -#4157=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 33','Referee Platforms',#4143,$,$); -#4158=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 35','Athletic Equipment Storage Racks',#4143,$,$); -#4159=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17','Playground Equipment',#4133,$,$); -#4160=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 11','Climbing Apparatus',#4159,$,$); -#4161=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 13','Climbing Walls',#4159,$,$); -#4162=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 13 11','Harness Equipment',#4161,$,$); -#4163=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 15','Merry Go Rounds',#4159,$,$); -#4164=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 17','Playhouse Gardens',#4159,$,$); -#4165=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 19','Rope Climbing Equipment',#4159,$,$); -#4166=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 21','Sand Tables',#4159,$,$); -#4167=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 23','Water Tables',#4159,$,$); -#4168=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 25','Sandboxes',#4159,$,$); -#4169=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 27','See Saws',#4159,$,$); -#4170=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 27 11','Spring, Rocking Equipment',#4169,$,$); -#4171=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 29','Slides',#4159,$,$); -#4172=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 31','Swings',#4159,$,$); -#4173=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 31 11','Harness Swings',#4172,$,$); -#4174=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 31 13','Rope Swings',#4172,$,$); -#4175=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 31 15','Tire Swings',#4172,$,$); -#4176=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 31 17','Seat Swings',#4172,$,$); -#4177=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 33','Playground Tunnel',#4159,$,$); -#4178=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 35','Play Structures',#4159,$,$); -#4179=IFCCLASSIFICATIONREFERENCE($,'23-21 29 19','Recreational Equipment',#4133,$,$); -#4180=IFCCLASSIFICATIONREFERENCE($,'23-21 29 19 11','Ping Pong Equipment',#4179,$,$); -#4181=IFCCLASSIFICATIONREFERENCE($,'23-21 29 19 13','Arcade Machines',#4179,$,$); -#4182=IFCCLASSIFICATIONREFERENCE($,'23-21 29 19 15','Billiards Equipment',#4179,$,$); -#4183=IFCCLASSIFICATIONREFERENCE($,'23-21 29 19 17','Sauna Equipment',#4179,$,$); -#4184=IFCCLASSIFICATIONREFERENCE($,'23-21 29 19 19','Steam Room Equipment',#4179,$,$); -#4185=IFCCLASSIFICATIONREFERENCE($,'23-21 29 19 21','Shooting Range Equipment',#4179,$,$); -#4186=IFCCLASSIFICATIONREFERENCE($,'23-21 29 19 23','Swimming Pool Equipment',#4179,$,$); -#4187=IFCCLASSIFICATIONREFERENCE($,'23-21 29 19 23 11','Diving Boards',#4186,$,$); -#4188=IFCCLASSIFICATIONREFERENCE($,'23-21 29 19 23 13','Starting Blocks',#4186,$,$); -#4189=IFCCLASSIFICATIONREFERENCE($,'23-21 29 19 23 15','Ladders',#4186,$,$); -#4190=IFCCLASSIFICATIONREFERENCE($,'23-21 29 21','Pools',#4133,$,$); -#4191=IFCCLASSIFICATIONREFERENCE($,'23-21 29 21 11','Leisure Whirlpools',#4190,$,$); -#4192=IFCCLASSIFICATIONREFERENCE($,'23-21 29 21 13','Hot Tubs',#4190,$,$); -#4193=IFCCLASSIFICATIONREFERENCE($,'23-21 29 21 15','Swimming Pools',#4190,$,$); -#4194=IFCCLASSIFICATIONREFERENCE($,'23-21 29 21 17','Lap Pools',#4190,$,$); -#4195=IFCCLASSIFICATIONREFERENCE($,'23-21 29 23','Spectator Stands',#4133,$,$); -#4196=IFCCLASSIFICATIONREFERENCE($,'23-21 29 23 11','Fixed Stadium Seating',#4195,$,$); -#4197=IFCCLASSIFICATIONREFERENCE($,'23-21 29 23 13','Telescoping Stands',#4195,$,$); -#4198=IFCCLASSIFICATIONREFERENCE($,'23-21 29 23 15','Bleachers',#4195,$,$); -#4199=IFCCLASSIFICATIONREFERENCE($,'23-21 29 23 15 11','Telescoping Bleachers',#4198,$,$); -#4200=IFCCLASSIFICATIONREFERENCE($,'23-21 29 23 17','Telescoping Chair Platforms',#4195,$,$); -#4201=IFCCLASSIFICATIONREFERENCE($,'23-21 31 00','Fitness and Exercise Equipment',#3626,$,$); -#4202=IFCCLASSIFICATIONREFERENCE($,'23-21 31 11','Exercise Apparatus',#4201,$,$); -#4203=IFCCLASSIFICATIONREFERENCE($,'23-21 31 11 11','Weight Training Exercise Apparatus',#4202,$,$); -#4204=IFCCLASSIFICATIONREFERENCE($,'23-21 31 11 11 11','Multi Station Weight Training Exercise Apparatus',#4203,$,$); -#4205=IFCCLASSIFICATIONREFERENCE($,'23-21 31 13','Exercise Bars',#4201,$,$); -#4206=IFCCLASSIFICATIONREFERENCE($,'23-21 31 13 11','Chinning Bars',#4205,$,$); -#4207=IFCCLASSIFICATIONREFERENCE($,'23-21 31 13 13','Weightlifting Bars',#4205,$,$); -#4208=IFCCLASSIFICATIONREFERENCE($,'23-21 31 15','Exercise Benches',#4201,$,$); -#4209=IFCCLASSIFICATIONREFERENCE($,'23-21 31 15 11','Weightlifting Benches',#4208,$,$); -#4210=IFCCLASSIFICATIONREFERENCE($,'23-21 31 15 11 11','Adjustable Utility Weightlifting Benches',#4209,$,$); -#4211=IFCCLASSIFICATIONREFERENCE($,'23-21 31 15 11 13','Decline Weightlifting Benches',#4209,$,$); -#4212=IFCCLASSIFICATIONREFERENCE($,'23-21 31 15 11 15','Incline Weightlifting Benches',#4209,$,$); -#4213=IFCCLASSIFICATIONREFERENCE($,'23-21 31 15 11 17','Supine Weightlifting Benches',#4209,$,$); -#4214=IFCCLASSIFICATIONREFERENCE($,'23-21 31 17','Exercise Boards',#4201,$,$); -#4215=IFCCLASSIFICATIONREFERENCE($,'23-21 31 17 11','Abdominal Exercise Boards',#4214,$,$); -#4216=IFCCLASSIFICATIONREFERENCE($,'23-21 31 17 11 11','Raised and Bent Leg Abdominal Exercise Boards',#4215,$,$); -#4217=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19','Exercise Machines',#4201,$,$); -#4218=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 11','Abdominal Exercise Machines',#4217,$,$); -#4219=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 13','Back Extension Exercise Machines',#4217,$,$); -#4220=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 15','Biceps Exercise Machines',#4217,$,$); -#4221=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 17','Chest Exercise Machines',#4217,$,$); -#4222=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 19','Closed Chain Exercise Machines',#4217,$,$); -#4223=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 21','Hip Exercise Machines',#4217,$,$); -#4224=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 21 11','Hip Abduction Exercise Machines',#4223,$,$); -#4225=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 21 13','Hip Adduction Exercise Machines',#4223,$,$); -#4226=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 23','Leg Exercise Machines',#4217,$,$); -#4227=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 23 11','Leg Curl Exercise Machines',#4226,$,$); -#4228=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 23 13','Leg Extension Exercise Machines',#4226,$,$); -#4229=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 23 15','Leg Press Exercise Machines',#4226,$,$); -#4230=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 23 17','Leg Press Squat Exercise Machines',#4226,$,$); -#4231=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 23 19','Leg Squat Exercise Machines',#4226,$,$); -#4232=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 25','Neck Exercise Machines',#4217,$,$); -#4233=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 27','Pullover Exercise Machines',#4217,$,$); -#4234=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 29','Rotary Shoulder Exercise Machines',#4217,$,$); -#4235=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 31','Rowing Exercise Machines',#4217,$,$); -#4236=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 33','Shoulder Exercise Machines',#4217,$,$); -#4237=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 35','Treadmills',#4217,$,$); -#4238=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 37','Triceps Exercise Machines',#4217,$,$); -#4239=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 39','Continuous Passive Motion CPM Exercisers',#4217,$,$); -#4240=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 41','Ladder Exercisers',#4217,$,$); -#4241=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 43','Exercise Platforms',#4217,$,$); -#4242=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 45','Ramp Curb Exercisers',#4217,$,$); -#4243=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 47','Staircase Exercisers',#4217,$,$); -#4244=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 49','Upper and Lower Extremities Exercisers',#4217,$,$); -#4245=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 51','Upper Body Exercisers',#4217,$,$); -#4246=IFCCLASSIFICATIONREFERENCE($,'23-21 31 21','Exercise Floor Mats',#4201,$,$); -#4247=IFCCLASSIFICATIONREFERENCE($,'23-21 31 23','Exercise Pulleys',#4201,$,$); -#4248=IFCCLASSIFICATIONREFERENCE($,'23-21 31 23 11','Triplex Exercise Pulleys',#4247,$,$); -#4249=IFCCLASSIFICATIONREFERENCE($,'23-21 33 00','Industrial and Manufacturing Equipment and Furnishings',#3626,$,$); -#4250=IFCCLASSIFICATIONREFERENCE($,'23-21 33 11','Manufacturing Equipment',#4249,$,$); -#4251=IFCCLASSIFICATIONREFERENCE($,'23-21 33 13','Manufacturing Furniture',#4249,$,$); -#4252=IFCCLASSIFICATIONREFERENCE($,'23-21 33 13 11','Flat Work Surface Furniture',#4251,$,$); -#4253=IFCCLASSIFICATIONREFERENCE($,'23-21 33 13 13','Work Stations',#4251,$,$); -#4254=IFCCLASSIFICATIONREFERENCE($,'23-21 33 15','Shop Equipment',#4249,$,$); -#4255=IFCCLASSIFICATIONREFERENCE($,'23-21 33 17','Shop Furniture',#4249,$,$); -#4256=IFCCLASSIFICATIONREFERENCE($,'23-21 33 17 11','Shop Work Surfaces',#4255,$,$); -#4257=IFCCLASSIFICATIONREFERENCE($,'23-21 33 17 13','Shop Storage Fittings',#4255,$,$); -#4258=IFCCLASSIFICATIONREFERENCE($,'23-21 35 00','Miscellaneous Equipment and Furnishings',#3626,$,$); -#4259=IFCCLASSIFICATIONREFERENCE($,'23-21 35 11','Darkroom Equipment and Furnishings',#4258,$,$); -#4260=IFCCLASSIFICATIONREFERENCE($,'23-21 35 11 11','Darkroom Processing Equipment',#4259,$,$); -#4261=IFCCLASSIFICATIONREFERENCE($,'23-21 35 13','Vending Equipment',#4258,$,$); -#4262=IFCCLASSIFICATIONREFERENCE($,'23-21 35 13 11','Vending Machines',#4261,$,$); -#4263=IFCCLASSIFICATIONREFERENCE($,'23-21 35 15','Ticket Machines',#4258,$,$); -#4264=IFCCLASSIFICATIONREFERENCE($,'23-21 35 17','Change Machines',#4258,$,$); -#4265=IFCCLASSIFICATIONREFERENCE($,'23-21 35 19','Vehicle Service Equipment',#4258,$,$); -#4266=IFCCLASSIFICATIONREFERENCE($,'23-21 35 19 11','Compressed Air Vehicle Service Equipment',#4265,$,$); -#4267=IFCCLASSIFICATIONREFERENCE($,'23-21 35 19 13','Fuel Dispensing Equipment',#4265,$,$); -#4268=IFCCLASSIFICATIONREFERENCE($,'23-21 35 19 15','Vehicle Lubrication Equipment',#4265,$,$); -#4269=IFCCLASSIFICATIONREFERENCE($,'23-21 35 19 17','Tire Changing Equipment',#4265,$,$); -#4270=IFCCLASSIFICATIONREFERENCE($,'23-21 35 19 19','Vehicle Washing Equipment',#4265,$,$); -#4271=IFCCLASSIFICATIONREFERENCE($,'23-21 35 19 21','Vehicle Hoists',#4265,$,$); -#4272=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21','Security and Vault Equipment and Furnishings',#4258,$,$); -#4273=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 11','Safes',#4272,$,$); -#4274=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 13','Safe Deposit Boxes',#4272,$,$); -#4275=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 15','Vault Doors',#4272,$,$); -#4276=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 17','Day Gates',#4272,$,$); -#4277=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 19','Anti Bandit Screens',#4272,$,$); -#4278=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 19 11','Gun Ports',#4277,$,$); -#4279=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 21','Teller and Service Equipment',#4272,$,$); -#4280=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 21 11','Automated Banking Systems',#4279,$,$); -#4281=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 21 13','Money Cart Pass Through',#4279,$,$); -#4282=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 21 15','Package Transfer Units',#4279,$,$); -#4283=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 21 17','Service and Teller Window Units',#4279,$,$); -#4284=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 21 19','Teller Equipment Systems',#4279,$,$); -#4285=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 21 21','Deal Drawers',#4279,$,$); -#4286=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 23','Key Security Cabinets',#4272,$,$); -#4287=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 25','Money Handling Equipment',#4272,$,$); -#4288=IFCCLASSIFICATIONREFERENCE($,'23-21 35 23','Detention Equipment and Furnishings',#4258,$,$); -#4289=IFCCLASSIFICATIONREFERENCE($,'23-21 35 23 11','Detention Enclosures',#4288,$,$); -#4290=IFCCLASSIFICATIONREFERENCE($,'23-21 35 23 13','Detention Furnishings and Specialties',#4288,$,$); -#4291=IFCCLASSIFICATIONREFERENCE($,'23-21 35 23 15','Detention Furniture',#4288,$,$); -#4292=IFCCLASSIFICATIONREFERENCE($,'23-21 35 25','Agricultural Equipment',#4258,$,$); -#4293=IFCCLASSIFICATIONREFERENCE($,'23-21 35 25 11','Milkers',#4292,$,$); -#4294=IFCCLASSIFICATIONREFERENCE($,'23-21 35 25 13','Stock Feeders',#4292,$,$); -#4295=IFCCLASSIFICATIONREFERENCE($,'23-21 35 25 15','Stock Waterers',#4292,$,$); -#4296=IFCCLASSIFICATIONREFERENCE($,'23-21 35 25 17','Waste Clean Up Equipment',#4292,$,$); -#4297=IFCCLASSIFICATIONREFERENCE($,'23-21 37 00','Furnishings, Ornaments, and Decoration',#3626,$,$); -#4298=IFCCLASSIFICATIONREFERENCE($,'23-21 37 11','Soft Furnishings',#4297,$,$); -#4299=IFCCLASSIFICATIONREFERENCE($,'23-21 37 11 11','Rugs',#4298,$,$); -#4300=IFCCLASSIFICATIONREFERENCE($,'23-21 37 11 13','Upholstery',#4298,$,$); -#4301=IFCCLASSIFICATIONREFERENCE($,'23-21 37 11 15','Cushions',#4298,$,$); -#4302=IFCCLASSIFICATIONREFERENCE($,'23-21 37 11 17','Padding',#4298,$,$); -#4303=IFCCLASSIFICATIONREFERENCE($,'23-21 37 11 19','Tablecloths',#4298,$,$); -#4304=IFCCLASSIFICATIONREFERENCE($,'23-21 37 13','Decoration',#4297,$,$); -#4305=IFCCLASSIFICATIONREFERENCE($,'23-21 37 13 11','Commercial Artwork',#4304,$,$); -#4306=IFCCLASSIFICATIONREFERENCE($,'23-21 37 13 11 11','Wall Hangings',#4305,$,$); -#4307=IFCCLASSIFICATIONREFERENCE($,'23-21 37 13 13','Clocks',#4304,$,$); -#4308=IFCCLASSIFICATIONREFERENCE($,'23-21 37 13 15','Mirrors',#4304,$,$); -#4309=IFCCLASSIFICATIONREFERENCE($,'23-21 37 13 17','Interior Ornamental Fountains',#4304,$,$); -#4310=IFCCLASSIFICATIONREFERENCE($,'23-21 37 13 19','Ornamental Screens',#4304,$,$); -#4311=IFCCLASSIFICATIONREFERENCE($,'23-21 37 13 21','Decorative Planters',#4304,$,$); -#4312=IFCCLASSIFICATIONREFERENCE($,'23-21 37 13 23','Decorative Vases',#4304,$,$); -#4313=IFCCLASSIFICATIONREFERENCE($,'23-21 39 00','Commercial Washing and Waste Disposal Equipment',#3626,$,$); -#4314=IFCCLASSIFICATIONREFERENCE($,'23-21 39 11','Commercial Washing Equipment',#4313,$,$); -#4315=IFCCLASSIFICATIONREFERENCE($,'23-21 39 11 11','High Pressure Washing Equipment',#4314,$,$); -#4316=IFCCLASSIFICATIONREFERENCE($,'23-21 39 13','Drain Boards',#4313,$,$); -#4317=IFCCLASSIFICATIONREFERENCE($,'23-21 41 00','Commercial Laundry Equipment',#3626,$,$); -#4318=IFCCLASSIFICATIONREFERENCE($,'23-21 41 11','Commercial Clothes Airers',#4317,$,$); -#4319=IFCCLASSIFICATIONREFERENCE($,'23-21 41 11 11','Commercial Clothes Dryers',#4318,$,$); -#4320=IFCCLASSIFICATIONREFERENCE($,'23-21 41 11 13','Commercial Clothes Stands',#4318,$,$); -#4321=IFCCLASSIFICATIONREFERENCE($,'23-21 41 11 15','Commercial Clothes Lines',#4318,$,$); -#4322=IFCCLASSIFICATIONREFERENCE($,'23-21 41 13','Commercial Combination Laundry Washer Dryers',#4317,$,$); -#4323=IFCCLASSIFICATIONREFERENCE($,'23-21 41 15','Commercial Dry Cleaning Equipment',#4317,$,$); -#4324=IFCCLASSIFICATIONREFERENCE($,'23-21 41 17','Commercial Laundry Dispensers',#4317,$,$); -#4325=IFCCLASSIFICATIONREFERENCE($,'23-21 41 17 11','Commercial Dry Laundry Detergent Dispensers',#4324,$,$); -#4326=IFCCLASSIFICATIONREFERENCE($,'23-21 41 17 13','Commercial Liquid Laundry Detergent Dispensers',#4324,$,$); -#4327=IFCCLASSIFICATIONREFERENCE($,'23-21 41 17 15','Commercial Dryer Sheet Dispensers',#4324,$,$); -#4328=IFCCLASSIFICATIONREFERENCE($,'23-21 41 19','Commercial Dry Cleaning Machines',#4317,$,$); -#4329=IFCCLASSIFICATIONREFERENCE($,'23-21 41 21','Commercial Laundry Extractors',#4317,$,$); -#4330=IFCCLASSIFICATIONREFERENCE($,'23-21 41 23','Commercial Flat Work Ironers',#4317,$,$); -#4331=IFCCLASSIFICATIONREFERENCE($,'23-21 41 23 11','Commercial Electric Flat Work Ironers',#4330,$,$); -#4332=IFCCLASSIFICATIONREFERENCE($,'23-21 41 23 13','Commercial Gas Flat Work Ironers',#4330,$,$); -#4333=IFCCLASSIFICATIONREFERENCE($,'23-21 41 23 15','Commercial Steam Flat Work Ironers',#4330,$,$); -#4334=IFCCLASSIFICATIONREFERENCE($,'23-21 41 25','Commercial Ironing and Pressing Machines',#4317,$,$); -#4335=IFCCLASSIFICATIONREFERENCE($,'23-21 41 27','Commercial Laundry Folding Machines',#4317,$,$); -#4336=IFCCLASSIFICATIONREFERENCE($,'23-21 41 29','Commercial Laundry Conveyors',#4317,$,$); -#4337=IFCCLASSIFICATIONREFERENCE($,'23-21 41 31','Commercial Laundry Dryers',#4317,$,$); -#4338=IFCCLASSIFICATIONREFERENCE($,'23-21 41 31 11','Commercial Electric Laundry Dryers',#4337,$,$); -#4339=IFCCLASSIFICATIONREFERENCE($,'23-21 41 31 13','Commercial Gas Laundry Dryers',#4337,$,$); -#4340=IFCCLASSIFICATIONREFERENCE($,'23-21 41 31 15','Commercial Steam Laundry Dryers',#4337,$,$); -#4341=IFCCLASSIFICATIONREFERENCE($,'23-21 41 33','Commercial Laundry Presses',#4317,$,$); -#4342=IFCCLASSIFICATIONREFERENCE($,'23-21 41 33 11','Commercial Electric Laundry Presses',#4341,$,$); -#4343=IFCCLASSIFICATIONREFERENCE($,'23-21 41 33 13','Commercial Gas Laundry Presses',#4341,$,$); -#4344=IFCCLASSIFICATIONREFERENCE($,'23-21 41 33 15','Commercial Steam Laundry Presses',#4341,$,$); -#4345=IFCCLASSIFICATIONREFERENCE($,'23-21 41 35','Commercial Laundry Spreader Feeders',#4317,$,$); -#4346=IFCCLASSIFICATIONREFERENCE($,'23-21 41 37','Commercial Laundry Steam Tunnels',#4317,$,$); -#4347=IFCCLASSIFICATIONREFERENCE($,'23-21 41 39','Commercial Laundry Tubs',#4317,$,$); -#4348=IFCCLASSIFICATIONREFERENCE($,'23-21 41 41','Commercial Washing Machines',#4317,$,$); -#4349=IFCCLASSIFICATIONREFERENCE($,'23-21 41 41 11','Commercial Front Loading Laundry Washers',#4348,$,$); -#4350=IFCCLASSIFICATIONREFERENCE($,'23-21 41 41 13','Commercial Side Loading Laundry Washers',#4348,$,$); -#4351=IFCCLASSIFICATIONREFERENCE($,'23-21 41 41 15','Commercial Top Loading Laundry Washers',#4348,$,$); -#4352=IFCCLASSIFICATIONREFERENCE($,'23-21 41 41 17','Commercial Tunnel Laundry Washers',#4348,$,$); -#4353=IFCCLASSIFICATIONREFERENCE($,'23-21 43 00','Cleaning Equipment',#3626,$,$); -#4354=IFCCLASSIFICATIONREFERENCE($,'23-21 43 11','Buckets',#4353,$,$); -#4355=IFCCLASSIFICATIONREFERENCE($,'23-21 43 11 11','Mop Buckets',#4354,$,$); -#4356=IFCCLASSIFICATIONREFERENCE($,'23-21 43 11 13','Waste Paper Baskets',#4354,$,$); -#4357=IFCCLASSIFICATIONREFERENCE($,'23-21 43 13','Cleaners',#4353,$,$); -#4358=IFCCLASSIFICATIONREFERENCE($,'23-21 43 13 11','Pressure Cleaners',#4357,$,$); -#4359=IFCCLASSIFICATIONREFERENCE($,'23-21 43 13 13','Steam Cleaners',#4357,$,$); -#4360=IFCCLASSIFICATIONREFERENCE($,'23-21 43 15','Custodial Dispensers',#4353,$,$); -#4361=IFCCLASSIFICATIONREFERENCE($,'23-21 43 15 11','Air Freshener Dispensers',#4360,$,$); -#4362=IFCCLASSIFICATIONREFERENCE($,'23-21 43 15 13','Bathroom Tissue Dispensers',#4360,$,$); -#4363=IFCCLASSIFICATIONREFERENCE($,'23-21 43 15 15','Cleaning Rag Dispensers',#4360,$,$); -#4364=IFCCLASSIFICATIONREFERENCE($,'23-21 43 15 17','Facial Tissue Dispensers',#4360,$,$); -#4365=IFCCLASSIFICATIONREFERENCE($,'23-21 43 15 19','Hand Cleaner Dispensers',#4360,$,$); -#4366=IFCCLASSIFICATIONREFERENCE($,'23-21 43 15 21','Institutional Soap Dispensers',#4360,$,$); -#4367=IFCCLASSIFICATIONREFERENCE($,'23-21 43 15 23','Lotion Dispensers',#4360,$,$); -#4368=IFCCLASSIFICATIONREFERENCE($,'23-21 43 15 25','Paper Towel Dispensers',#4360,$,$); -#4369=IFCCLASSIFICATIONREFERENCE($,'23-21 43 15 27','Sanitary Goods Dispensers',#4360,$,$); -#4370=IFCCLASSIFICATIONREFERENCE($,'23-21 43 15 29','Toilet Accessories Dispensers',#4360,$,$); -#4371=IFCCLASSIFICATIONREFERENCE($,'23-21 43 15 31','Toilet Tissue Dispensers',#4360,$,$); -#4372=IFCCLASSIFICATIONREFERENCE($,'23-21 43 15 33','Urinal Accessories Dispensers',#4360,$,$); -#4373=IFCCLASSIFICATIONREFERENCE($,'23-21 43 17','Duct Cleaning Machines',#4353,$,$); -#4374=IFCCLASSIFICATIONREFERENCE($,'23-21 43 19','Floor Cleaning Equipment',#4353,$,$); -#4375=IFCCLASSIFICATIONREFERENCE($,'23-21 43 19 11','Floor Burnishers',#4374,$,$); -#4376=IFCCLASSIFICATIONREFERENCE($,'23-21 43 19 13','Floor Polishers',#4374,$,$); -#4377=IFCCLASSIFICATIONREFERENCE($,'23-21 43 19 15','Floor Scrapers',#4374,$,$); -#4378=IFCCLASSIFICATIONREFERENCE($,'23-21 43 19 17','Floor Scrubbers',#4374,$,$); -#4379=IFCCLASSIFICATIONREFERENCE($,'23-21 43 19 19','Floor Sweepers',#4374,$,$); -#4380=IFCCLASSIFICATIONREFERENCE($,'23-21 43 19 19 11','Carpet Sweepers',#4379,$,$); -#4381=IFCCLASSIFICATIONREFERENCE($,'23-21 43 19 21','Floor Washing Machines',#4374,$,$); -#4382=IFCCLASSIFICATIONREFERENCE($,'23-21 43 21','Room Cleaning Equipment',#4353,$,$); -#4383=IFCCLASSIFICATIONREFERENCE($,'23-21 43 21 11','Vacuum Cleaning Equipment',#4382,$,$); -#4384=IFCCLASSIFICATIONREFERENCE($,'23-21 43 21 11 11','Vacuum Cleaning Systems',#4383,$,$); -#4385=IFCCLASSIFICATIONREFERENCE($,'23-21 43 21 11 11 11','Centralized Vacuum Cleaning System',#4384,$,$); -#4386=IFCCLASSIFICATIONREFERENCE($,'23-21 43 21 11 13','Vacuum Cleaners',#4383,$,$); -#4387=IFCCLASSIFICATIONREFERENCE($,'23-21 43 21 11 13 11','Heavy Duty Tank Vacuum Cleaners',#4386,$,$); -#4388=IFCCLASSIFICATIONREFERENCE($,'23-21 43 21 11 13 13','Wet Dry Combination Vacuum Cleaners',#4386,$,$); -#4389=IFCCLASSIFICATIONREFERENCE($,'23-21 43 21 11 13 15','Wet Vacuum Cleaners',#4386,$,$); -#4390=IFCCLASSIFICATIONREFERENCE($,'23-21 43 21 13','Floor and Wall Cleaning',#4382,$,$); -#4391=IFCCLASSIFICATIONREFERENCE($,'23-21 43 21 15','Housekeeping Carts',#4382,$,$); -#4392=IFCCLASSIFICATIONREFERENCE($,'23-21 43 23','Sanitary Waste Receptacles',#4353,$,$); -#4393=IFCCLASSIFICATIONREFERENCE($,'23-21 43 23 11','Installed Sanitary Waste Receptacles',#4392,$,$); -#4394=IFCCLASSIFICATIONREFERENCE($,'23-21 43 23 13','Portable Sanitary Waste Receptacles',#4392,$,$); -#4395=IFCCLASSIFICATIONREFERENCE($,'23-21 43 25','Custodial Sinks',#4353,$,$); -#4396=IFCCLASSIFICATIONREFERENCE($,'23-21 43 25 11','Mop Sinks',#4395,$,$); -#4397=IFCCLASSIFICATIONREFERENCE($,'23-21 43 27','Custodial Washers',#4353,$,$); -#4398=IFCCLASSIFICATIONREFERENCE($,'23-21 43 27 11','Trash Can Pedestal Washers',#4397,$,$); -#4399=IFCCLASSIFICATIONREFERENCE($,'23-21 45 00','Historic Preservation Products',#3626,$,$); -#4400=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11','Fine Art',#4399,$,$); -#4401=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 11','Two Dimensional Art',#4400,$,$); -#4402=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 11 11','Fine Art Paintings',#4401,$,$); -#4403=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 11 13','Fine Art Drawings',#4401,$,$); -#4404=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 11 15','Fine Art Printmaking',#4401,$,$); -#4405=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 11 15 11','Fine Art Lithography',#4404,$,$); -#4406=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 11 15 13','Fine Art Intaglio',#4404,$,$); -#4407=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 11 15 15','Fine Art Prints',#4404,$,$); -#4408=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 11 17','Fine Art Photography',#4401,$,$); -#4409=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 11 19','Fine Art Graphic Designs',#4401,$,$); -#4410=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 11 21','Fine Art Illustrations',#4401,$,$); -#4411=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 13','Three Dimensional Art',#4400,$,$); -#4412=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 13 11','Fine Art Sculpture',#4411,$,$); -#4413=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 13 13','Fine Art Ceramics',#4411,$,$); -#4414=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 13 13 11','Fine Art Pottery',#4413,$,$); -#4415=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 13 15','Fine Art Mosaics',#4411,$,$); -#4416=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 13 15 11','Fine Art Tile',#4415,$,$); -#4417=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 13 17','Fine Art Glass',#4411,$,$); -#4418=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 13 17 11','Fine Art Stained Glass',#4417,$,$); -#4419=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 13 17 13','Fine Art Etched Glass',#4417,$,$); -#4420=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 13 19','Fine Art Architecture',#4411,$,$); -#4421=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 13 19 11','Fine Art Decorative Architecture',#4420,$,$); -#4422=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 13 21','Fine Art Textile',#4411,$,$); -#4423=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 13 21 11','Fine Art Tapestry',#4422,$,$); -#4424=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 15','Four Dimensional Art',#4400,$,$); -#4425=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 15 11','Fine Art Film',#4424,$,$); -#4426=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 15 13','Fine Art Video',#4424,$,$); -#4427=IFCCLASSIFICATIONREFERENCE($,'23-21 45 13','Historic Documents',#4399,$,$); -#4428=IFCCLASSIFICATIONREFERENCE($,'23-21 45 13 11','Historic Paper Documents',#4427,$,$); -#4429=IFCCLASSIFICATIONREFERENCE($,'23-21 45 13 13','Historic Velum Documents',#4427,$,$); -#4430=IFCCLASSIFICATIONREFERENCE($,'23-21 45 13 15','Historic Parchment Documents',#4427,$,$); -#4431=IFCCLASSIFICATIONREFERENCE($,'23-21 45 15','Historic Architectural Items',#4399,$,$); -#4432=IFCCLASSIFICATIONREFERENCE($,'23-21 45 15 11','Historic Architectural Models',#4431,$,$); -#4433=IFCCLASSIFICATIONREFERENCE($,'23-21 45 15 13','Historic Architectural Constructions',#4431,$,$); -#4434=IFCCLASSIFICATIONREFERENCE($,'23-21 45 15 15','Historic Architectural Designs',#4431,$,$); -#4435=IFCCLASSIFICATIONREFERENCE($,'23-21 45 15 17','Historic Decorative Architectures',#4431,$,$); -#4436=IFCCLASSIFICATIONREFERENCE($,'23-21 47 00','Musical Equipment',#3626,$,$); -#4437=IFCCLASSIFICATIONREFERENCE($,'23-21 47 11','Conductor Equipment',#4436,$,$); -#4438=IFCCLASSIFICATIONREFERENCE($,'23-21 47 11 11','Conductor Podium',#4437,$,$); -#4439=IFCCLASSIFICATIONREFERENCE($,'23-21 47 11 13','Conductor Platform',#4437,$,$); -#4440=IFCCLASSIFICATIONREFERENCE($,'23-21 47 13','Musical Instrument',#4436,$,$); -#4441=IFCCLASSIFICATIONREFERENCE($,'23-21 47 13 11','String Instrument',#4440,$,$); -#4442=IFCCLASSIFICATIONREFERENCE($,'23-21 47 13 11 11','Piano',#4441,$,$); -#4443=IFCCLASSIFICATIONREFERENCE($,'23-23 00 00','Conveying Systems and Material Handling Products',#1604,$,$); -#4444=IFCCLASSIFICATIONREFERENCE($,'23-23 11 00','Vertical Transportation Equipment',#4443,$,$); -#4445=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11','Elevators',#4444,$,$); -#4446=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 11','Traction Elevators',#4445,$,$); -#4447=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 11 11','Freight Traction Elevators',#4446,$,$); -#4448=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 11 13','Passenger Traction Elevators',#4446,$,$); -#4449=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 11 15','Residential Traction Elevators',#4446,$,$); -#4450=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 11 17','Service Traction Elevators',#4446,$,$); -#4451=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 13','Hydraulic Elevators',#4445,$,$); -#4452=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 13 11','Freight Hydraulic Elevators',#4451,$,$); -#4453=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 13 13','Passenger Hydraulic Elevators',#4451,$,$); -#4454=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 13 15','Residential Hydraulic Elevators',#4451,$,$); -#4455=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 13 17','Service Hydraulic Elevators',#4451,$,$); -#4456=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 15','Pneumatic Elevators',#4445,$,$); -#4457=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 15 11','Pneumatic Passenger Elevators',#4456,$,$); -#4458=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 17','Rack and Pinion Elevators',#4445,$,$); -#4459=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 19','Elevator Cabs',#4445,$,$); -#4460=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 21','Elevator Equipment and Controls',#4445,$,$); -#4461=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 21 11','Elevator Doors',#4460,$,$); -#4462=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 21 13','Elevator Controls',#4460,$,$); -#4463=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 23','Elevator Restoration Products',#4445,$,$); -#4464=IFCCLASSIFICATIONREFERENCE($,'23-23 11 13','Escalators',#4444,$,$); -#4465=IFCCLASSIFICATIONREFERENCE($,'23-23 13 00','Lifting Equipment',#4443,$,$); -#4466=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11','Lifts',#4465,$,$); -#4467=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 11','Boom Lifts',#4466,$,$); -#4468=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 13','Fork Lifts',#4466,$,$); -#4469=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 15','Man Lifts',#4466,$,$); -#4470=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 17','Patient Lifts',#4466,$,$); -#4471=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 17 11','Installed Patient Lifts',#4470,$,$); -#4472=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 17 13','Portable Patient Lifts',#4470,$,$); -#4473=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 19','Platform Lifts',#4466,$,$); -#4474=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 19 11','Elevating Platform Lifts',#4473,$,$); -#4475=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 19 13','Inclined Platform Lifts',#4473,$,$); -#4476=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 19 15','Scissor Platform Lifts',#4473,$,$); -#4477=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 21','Scaffold Lifts',#4466,$,$); -#4478=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 23','Stage Screen Lifts',#4466,$,$); -#4479=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 25','Wheel Chair Lifts',#4466,$,$); -#4480=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 25 11','Hydraulic Wheel Chair Lifts',#4479,$,$); -#4481=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 25 11 11','Hydraulic Wheel Chair Rail Lifts',#4480,$,$); -#4482=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 25 11 13','Hydraulic Wheel Chair Stair Lifts',#4480,$,$); -#4483=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 25 11 15','Hydraulic Wheel Chair Vertical Lifts',#4480,$,$); -#4484=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 25 13','Mechanical Wheel Chair Lifts',#4479,$,$); -#4485=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 25 13 11','Mechanical Wheel Chair Rail Lifts',#4484,$,$); -#4486=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 25 13 13','Mechanical Wheel Chair Stair Lifts',#4484,$,$); -#4487=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 25 13 15','Mechanical Wheel Chair Vertical Lifts',#4484,$,$); -#4488=IFCCLASSIFICATIONREFERENCE($,'23-23 15 00','Horizontal Transportation Equipment',#4443,$,$); -#4489=IFCCLASSIFICATIONREFERENCE($,'23-23 15 11','Moving Walks',#4488,$,$); -#4490=IFCCLASSIFICATIONREFERENCE($,'23-23 15 13','People Movers',#4488,$,$); -#4491=IFCCLASSIFICATIONREFERENCE($,'23-23 15 13 11','Monorails',#4490,$,$); -#4492=IFCCLASSIFICATIONREFERENCE($,'23-23 15 13 13','Duorails',#4490,$,$); -#4493=IFCCLASSIFICATIONREFERENCE($,'23-23 15 13 15','Maglevs',#4490,$,$); -#4494=IFCCLASSIFICATIONREFERENCE($,'23-23 15 15','Jetways',#4488,$,$); -#4495=IFCCLASSIFICATIONREFERENCE($,'23-23 15 17','Transportation Gangways',#4488,$,$); -#4496=IFCCLASSIFICATIONREFERENCE($,'23-23 17 00','Materials Handling',#4443,$,$); -#4497=IFCCLASSIFICATIONREFERENCE($,'23-23 17 11','Dumbwaiters',#4496,$,$); -#4498=IFCCLASSIFICATIONREFERENCE($,'23-23 17 11 11','Manual Dumbwaiters',#4497,$,$); -#4499=IFCCLASSIFICATIONREFERENCE($,'23-23 17 11 13','Hydraulic Dumbwaiters',#4497,$,$); -#4500=IFCCLASSIFICATIONREFERENCE($,'23-23 17 11 15','Traction Dumbwaiters',#4497,$,$); -#4501=IFCCLASSIFICATIONREFERENCE($,'23-23 17 13','Material Transport',#4496,$,$); -#4502=IFCCLASSIFICATIONREFERENCE($,'23-23 17 13 11','Automated Document Filing and Retrieval',#4501,$,$); -#4503=IFCCLASSIFICATIONREFERENCE($,'23-23 17 13 13','Automated Guided Vehicles',#4501,$,$); -#4504=IFCCLASSIFICATIONREFERENCE($,'23-23 17 13 13 11','Guided Vehicle Material Handling',#4503,$,$); -#4505=IFCCLASSIFICATIONREFERENCE($,'23-23 17 13 13 13','Track Vehicle Material Handling',#4503,$,$); -#4506=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15','Conveyors',#4496,$,$); -#4507=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 11','Conveyor Components',#4506,$,$); -#4508=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 11 11','Conveyor Belts',#4507,$,$); -#4509=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 11 13','Conveyor Rollers',#4507,$,$); -#4510=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 13','Belt Conveyors',#4506,$,$); -#4511=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 15','Bucket Conveyors',#4506,$,$); -#4512=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 17','Container Conveyors',#4506,$,$); -#4513=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 19','Hopper and Track Conveyors',#4506,$,$); -#4514=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 21','Monorail Conveyors',#4506,$,$); -#4515=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 23','Oscillating Conveyors',#4506,$,$); -#4516=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 25','Pneumatic Conveyors',#4506,$,$); -#4517=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 27','Roller Conveyors',#4506,$,$); -#4518=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 29','Scoop Conveyors',#4506,$,$); -#4519=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 31','Screw Conveyors',#4506,$,$); -#4520=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 33','Selective Vertical Conveyors',#4506,$,$); -#4521=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 35','Postal Conveyors',#4506,$,$); -#4522=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 37','Baggage Conveying and Dispensing Equipment',#4506,$,$); -#4523=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 37 11','Baggage Conveyors',#4522,$,$); -#4524=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 37 13','Baggage Dispensing Units',#4522,$,$); -#4525=IFCCLASSIFICATIONREFERENCE($,'23-23 17 17','Chutes',#4496,$,$); -#4526=IFCCLASSIFICATIONREFERENCE($,'23-23 17 17 11','Coal Chutes',#4525,$,$); -#4527=IFCCLASSIFICATIONREFERENCE($,'23-23 17 17 13','Dry Bulk Materials Chutes',#4525,$,$); -#4528=IFCCLASSIFICATIONREFERENCE($,'23-23 17 17 15','Laundry and Linen Chutes',#4525,$,$); -#4529=IFCCLASSIFICATIONREFERENCE($,'23-23 17 17 17','Package Chutes',#4525,$,$); -#4530=IFCCLASSIFICATIONREFERENCE($,'23-23 17 17 19','Refuse Chutes',#4525,$,$); -#4531=IFCCLASSIFICATIONREFERENCE($,'23-23 17 19','Feeder Equipment',#4496,$,$); -#4532=IFCCLASSIFICATIONREFERENCE($,'23-23 17 19 11','Apron Feeders',#4531,$,$); -#4533=IFCCLASSIFICATIONREFERENCE($,'23-23 17 19 13','Reciprocating Plate Feeders',#4531,$,$); -#4534=IFCCLASSIFICATIONREFERENCE($,'23-23 17 19 15','Rotary Airlock Feeders',#4531,$,$); -#4535=IFCCLASSIFICATIONREFERENCE($,'23-23 17 19 17','Rotary Flow Feeders',#4531,$,$); -#4536=IFCCLASSIFICATIONREFERENCE($,'23-23 17 19 19','Vibratory Feeders',#4531,$,$); -#4537=IFCCLASSIFICATIONREFERENCE($,'23-23 17 21','Pneumatic Tube Systems',#4496,$,$); -#4538=IFCCLASSIFICATIONREFERENCE($,'23-23 17 21 11','Pneumatic Tubes',#4537,$,$); -#4539=IFCCLASSIFICATIONREFERENCE($,'23-23 17 21 13','Pneumatic Tube Controls',#4537,$,$); -#4540=IFCCLASSIFICATIONREFERENCE($,'23-23 17 21 15','Pneumatic Tube Vacuum Boxes',#4537,$,$); -#4541=IFCCLASSIFICATIONREFERENCE($,'23-23 17 21 17','Document Conveying Systems',#4537,$,$); -#4542=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23','Cranes',#4496,$,$); -#4543=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 11','Hydraulic Cranes',#4542,$,$); -#4544=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 11 11','Hydraulic Bridge Cranes',#4543,$,$); -#4545=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 11 11 11','Top Running Hydraulic Overhead Cranes',#4544,$,$); -#4546=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 11 11 13','Underslung Hydraulic Overhead Cranes',#4544,$,$); -#4547=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 11 13','Hydraulic Gantry Cranes',#4543,$,$); -#4548=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 11 15','Hydraulic Jib Cranes',#4543,$,$); -#4549=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 11 17','Hydraulic Mobile Cranes',#4543,$,$); -#4550=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 11 19','Hydraulic Terrain Cranes',#4543,$,$); -#4551=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 11 21','Hydraulic Top Running Overhead Cranes',#4543,$,$); -#4552=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 11 23','Hydraulic Tower Cranes',#4543,$,$); -#4553=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 11 25','Hydraulic Track Cranes',#4543,$,$); -#4554=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 11 27','Hydraulic Underslung Overhead Cranes',#4543,$,$); -#4555=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 11 29','Hydraulic Workshop Cranes',#4543,$,$); -#4556=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 13','Mechanical Cranes',#4542,$,$); -#4557=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 13 11','Mechanical Bridge Cranes',#4556,$,$); -#4558=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 13 11 11','Top Running Mechanical Overhead Cranes',#4557,$,$); -#4559=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 13 11 13','Underslung Mechanical Overhead Cranes',#4557,$,$); -#4560=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 13 13','Mechanical Gantry Cranes',#4556,$,$); -#4561=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 13 15','Mechanical Jib Cranes',#4556,$,$); -#4562=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 13 17','Mechanical Mobile Cranes',#4556,$,$); -#4563=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 13 19','Mechanical Terrain Cranes',#4556,$,$); -#4564=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 13 21','Mechanical Top Running Overhead Cranes',#4556,$,$); -#4565=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 13 23','Mechanical Tower Cranes',#4556,$,$); -#4566=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 13 25','Mechanical Track Cranes',#4556,$,$); -#4567=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 13 27','Mechanical Underslung Overhead Cranes',#4556,$,$); -#4568=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 13 29','Mechanical Workshop Cranes',#4556,$,$); -#4569=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 15','Electric Cranes',#4542,$,$); -#4570=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 15 11','Electric Bridge Cranes',#4569,$,$); -#4571=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 15 13','Top Running Electric Overhead Cranes',#4569,$,$); -#4572=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 15 15','Underslung Electric Overhead Cranes',#4569,$,$); -#4573=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 15 17','Electric Gantry Cranes',#4569,$,$); -#4574=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 15 19','Electric Jib Cranes',#4569,$,$); -#4575=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 15 21','Electric Mobile Cranes',#4569,$,$); -#4576=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 15 23','Electric Terrain Cranes',#4569,$,$); -#4577=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 15 25','Electric Top Running Overhead Cranes',#4569,$,$); -#4578=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 15 27','Electric Tower Cranes',#4569,$,$); -#4579=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 15 29','Electric Track Cranes',#4569,$,$); -#4580=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 15 31','Electric Underslung Overhead Cranes',#4569,$,$); -#4581=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 15 33','Electric Workshop Cranes',#4569,$,$); -#4582=IFCCLASSIFICATIONREFERENCE($,'23-23 17 25','Derricks',#4496,$,$); -#4583=IFCCLASSIFICATIONREFERENCE($,'23-23 17 27','Hoists',#4496,$,$); -#4584=IFCCLASSIFICATIONREFERENCE($,'23-23 17 27 11','Fixed Hoists',#4583,$,$); -#4585=IFCCLASSIFICATIONREFERENCE($,'23-23 17 27 11 11','Pneumatic Fixed Hoists',#4584,$,$); -#4586=IFCCLASSIFICATIONREFERENCE($,'23-23 17 27 11 13','Electric Fixed Hoists',#4584,$,$); -#4587=IFCCLASSIFICATIONREFERENCE($,'23-23 17 27 11 15','Manual Fixed Hoists',#4584,$,$); -#4588=IFCCLASSIFICATIONREFERENCE($,'23-23 17 27 11 17','Hydraulic Fixed Hoists',#4584,$,$); -#4589=IFCCLASSIFICATIONREFERENCE($,'23-23 17 27 13','Trolley Hoists',#4583,$,$); -#4590=IFCCLASSIFICATIONREFERENCE($,'23-23 17 27 13 11','Pneumatic Trolley Hoists',#4589,$,$); -#4591=IFCCLASSIFICATIONREFERENCE($,'23-23 17 27 13 13','Electric Trolley Hoists',#4589,$,$); -#4592=IFCCLASSIFICATIONREFERENCE($,'23-23 17 27 13 15','Manual Trolley Hoists',#4589,$,$); -#4593=IFCCLASSIFICATIONREFERENCE($,'23-23 17 27 13 17','Hydraulic Trolley Hoists',#4589,$,$); -#4594=IFCCLASSIFICATIONREFERENCE($,'23-23 19 00','Turntables',#4443,$,$); -#4595=IFCCLASSIFICATIONREFERENCE($,'23-23 19 11','Stage Turntables',#4594,$,$); -#4596=IFCCLASSIFICATIONREFERENCE($,'23-23 19 13','Exhibit and Display Turntables',#4594,$,$); -#4597=IFCCLASSIFICATIONREFERENCE($,'23-23 19 15','Vehicular Turntable',#4594,$,$); -#4598=IFCCLASSIFICATIONREFERENCE($,'23-23 21 00','Parking Systems',#4443,$,$); -#4599=IFCCLASSIFICATIONREFERENCE($,'23-23 21 11','Car Parking Systems',#4598,$,$); -#4600=IFCCLASSIFICATIONREFERENCE($,'23-23 23 00','Loading Dock Equipment',#4443,$,$); -#4601=IFCCLASSIFICATIONREFERENCE($,'23-23 23 11','Loading Dock Bumpers Seals',#4600,$,$); -#4602=IFCCLASSIFICATIONREFERENCE($,'23-23 23 13','Dock Levelers',#4600,$,$); -#4603=IFCCLASSIFICATIONREFERENCE($,'23-23 23 13 11','Powered Dock Levelers',#4602,$,$); -#4604=IFCCLASSIFICATIONREFERENCE($,'23-23 23 13 13','Manual Dock Levelers',#4602,$,$); -#4605=IFCCLASSIFICATIONREFERENCE($,'23-23 23 13 15','Hydraulic Dock Levelers',#4602,$,$); -#4606=IFCCLASSIFICATIONREFERENCE($,'23-23 23 15','Loading Dock Lifts',#4600,$,$); -#4607=IFCCLASSIFICATIONREFERENCE($,'23-23 23 15 11','Powered Loading Dock Lifts',#4606,$,$); -#4608=IFCCLASSIFICATIONREFERENCE($,'23-23 23 15 13','Manual Loading Dock Lifts',#4606,$,$); -#4609=IFCCLASSIFICATIONREFERENCE($,'23-23 23 17','Loading Dock Ramps And Bridges',#4600,$,$); -#4610=IFCCLASSIFICATIONREFERENCE($,'23-23 23 17 11','Portable Loading Dock Ramps',#4609,$,$); -#4611=IFCCLASSIFICATIONREFERENCE($,'23-23 23 17 13','Portable Loading Dock Bridges',#4609,$,$); -#4612=IFCCLASSIFICATIONREFERENCE($,'23-23 23 17 15','Portable Loading Dock Platforms',#4609,$,$); -#4613=IFCCLASSIFICATIONREFERENCE($,'23-23 23 19','Loading Dock Seals',#4600,$,$); -#4614=IFCCLASSIFICATIONREFERENCE($,'23-23 23 19 11','Inflatable Loading Dock Seals',#4613,$,$); -#4615=IFCCLASSIFICATIONREFERENCE($,'23-23 23 19 13','Loading Dock Weather Seals',#4613,$,$); -#4616=IFCCLASSIFICATIONREFERENCE($,'23-23 23 21','Loading Dock Shelters',#4600,$,$); -#4617=IFCCLASSIFICATIONREFERENCE($,'23-23 23 23','Loading Dock Vehicle Restraints',#4600,$,$); -#4618=IFCCLASSIFICATIONREFERENCE($,'23-23 23 23 11','Electric Loading Dock Vehicle Restraints',#4617,$,$); -#4619=IFCCLASSIFICATIONREFERENCE($,'23-23 23 23 13','Electro Magnetic Loading Dock Vehicle Restraints',#4617,$,$); -#4620=IFCCLASSIFICATIONREFERENCE($,'23-23 23 23 15','Hydraulic Loading Dock Vehicle Restraints',#4617,$,$); -#4621=IFCCLASSIFICATIONREFERENCE($,'23-23 25 00','Scaffolding',#4443,$,$); -#4622=IFCCLASSIFICATIONREFERENCE($,'23-23 25 11','Suspended Scaffolding',#4621,$,$); -#4623=IFCCLASSIFICATIONREFERENCE($,'23-23 25 11 11','Beam Suspended Scaffolding',#4622,$,$); -#4624=IFCCLASSIFICATIONREFERENCE($,'23-23 25 11 13','Carriage Suspended Scaffolding',#4622,$,$); -#4625=IFCCLASSIFICATIONREFERENCE($,'23-23 25 11 15','Hook Suspended Scaffolding',#4622,$,$); -#4626=IFCCLASSIFICATIONREFERENCE($,'23-23 25 13','Scaffolding Rope Climbers',#4621,$,$); -#4627=IFCCLASSIFICATIONREFERENCE($,'23-23 25 13 11','Scaffolding Manual Rope Climbers',#4626,$,$); -#4628=IFCCLASSIFICATIONREFERENCE($,'23-23 25 13 13','Scaffolding Powered Rope Climbers',#4626,$,$); -#4629=IFCCLASSIFICATIONREFERENCE($,'23-23 25 15','Scaffolding Telescoping Platforms',#4621,$,$); -#4630=IFCCLASSIFICATIONREFERENCE($,'23-23 25 15 11','Electric and Battery Scaffolding Telescoping Platforms',#4629,$,$); -#4631=IFCCLASSIFICATIONREFERENCE($,'23-23 25 15 13','Pneumatic Scaffolding Telescoping Platforms',#4629,$,$); -#4632=IFCCLASSIFICATIONREFERENCE($,'23-23 25 17','Powered Scaffolding',#4621,$,$); -#4633=IFCCLASSIFICATIONREFERENCE($,'23-25 00 00','Medical and Laboratory Equipment',#1604,$,$); -#4634=IFCCLASSIFICATIONREFERENCE($,'23-25 11 00','Anesthesiology and Respiratory Products',#4633,$,$); -#4635=IFCCLASSIFICATIONREFERENCE($,'23-25 11 11','Anesthesiology Furnishings',#4634,$,$); -#4636=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13','Anesthesiology Equipment',#4634,$,$); -#4637=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 11','Anesthesia Carts',#4636,$,$); -#4638=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 13','Anesthesia Gas Equipment',#4636,$,$); -#4639=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 15','Anesthesia Absorber Units',#4636,$,$); -#4640=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 17','Anesthesia Temperature Control Units',#4636,$,$); -#4641=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 19','Anesthesia Intrathecal Pumps',#4636,$,$); -#4642=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 21','Anesthesia Equipment Calibrators',#4636,$,$); -#4643=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 23','Anesthesia Inhalation Analgesia Units',#4636,$,$); -#4644=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 23 11','Anesthesia Inhalation Analgesia Central Gases and Vacuum Units',#4643,$,$); -#4645=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 23 13','Anesthesia Inhalation Analgesia Central Vacuum Only Units',#4643,$,$); -#4646=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 25','Respiratory Monitoring Products',#4636,$,$); -#4647=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 25 11','Apnea Monitors',#4646,$,$); -#4648=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 25 13','Arterial Blood Gas Monitors',#4646,$,$); -#4649=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 25 15','Carbon Dioxide End Tidal Monitors',#4646,$,$); -#4650=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 25 17','Esophageal Motility Recording Units',#4646,$,$); -#4651=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 25 19','Esophageal Stethoscopes',#4646,$,$); -#4652=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 25 21','Oxygen Analyzers',#4646,$,$); -#4653=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 25 23','Oxygen Monitors',#4646,$,$); -#4654=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 25 25','Respiratory Monitoring Kits',#4646,$,$); -#4655=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27','Pulmonary Function Products',#4636,$,$); -#4656=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 11','Bedside Pulmonary Function Screeners',#4655,$,$); -#4657=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 13','Body Plethysmographs',#4655,$,$); -#4658=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 15','Pneumotachs',#4655,$,$); -#4659=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 15 11','Lilly Pneumotachs',#4658,$,$); -#4660=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 15 13','Fleisch Pneumotachs',#4658,$,$); -#4661=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 17','Pulmonary Calibration Devices',#4655,$,$); -#4662=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 19','Pulmonary Function Calculators',#4655,$,$); -#4663=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 21','Pulmonary Function With Computer Analyzers',#4655,$,$); -#4664=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 23','Pulmonary Gas Analyzers',#4655,$,$); -#4665=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 25','Pulmonary Gas Monitors',#4655,$,$); -#4666=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 27','Pulmonary Peak Flowmeters',#4655,$,$); -#4667=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 29','Pulmonary Pressure Monitors',#4655,$,$); -#4668=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 31','Pulmonary Ventilation Monitors',#4655,$,$); -#4669=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 33','Respiratory Temperature Monitors',#4655,$,$); -#4670=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 35','Sleep Study Monitors',#4655,$,$); -#4671=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 37','Spirometers',#4655,$,$); -#4672=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 37 11','Diagnostic Spirometers',#4671,$,$); -#4673=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 37 13','Monitoring Spirometers',#4671,$,$); -#4674=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 37 15','Therapeutic Spirometers',#4671,$,$); -#4675=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 29','Oxygen Delivery Products',#4636,$,$); -#4676=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 29 11','Oxygen Concentrators',#4675,$,$); -#4677=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 29 13','Oxygen Air Blenders',#4675,$,$); -#4678=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 29 15','Oxygen Timers',#4675,$,$); -#4679=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 29 17','Oxygen Compressors',#4675,$,$); -#4680=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 29 19','Medical Oxygen Head Hoods',#4675,$,$); -#4681=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 29 21','Medical Oxygen Aerosol Tents',#4675,$,$); -#4682=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 29 23','Medical Hyperbaric Chambers',#4675,$,$); -#4683=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 29 25','Medical Inhalators',#4675,$,$); -#4684=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 29 27','Oxygen Therapy Delivery Equipment',#4675,$,$); -#4685=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 29 29','Medical Oxygen Insufflators',#4675,$,$); -#4686=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 29 31','Liquid Oxygen Converters',#4675,$,$); -#4687=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 31','Airway Management Products',#4636,$,$); -#4688=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 31 11','Airway Pressure Gages',#4687,$,$); -#4689=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 31 13','Pharyngometers',#4687,$,$); -#4690=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 33','Intubation Products',#4636,$,$); -#4691=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 33 11','Laryngoscopes',#4690,$,$); -#4692=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 33 13','Intubation Benders',#4690,$,$); -#4693=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 33 15','Intubation Gauges',#4690,$,$); -#4694=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 33 17','Carbon Dioxide Patient Detectors',#4690,$,$); -#4695=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 33 19','Intubation Suction Pumps',#4690,$,$); -#4696=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 35','Negative Pressure Ventilators',#4636,$,$); -#4697=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 35 11','Iron Lungs',#4696,$,$); -#4698=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 35 13','Chest Cuirass Products',#4696,$,$); -#4699=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 37','Positive Pressure Ventilators',#4636,$,$); -#4700=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 37 11','Intermittent Positive Pressure Breathing Ventilator Units',#4699,$,$); -#4701=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 37 13','Non Invasive Continuous Positive Air Pressure Ventilator Units',#4699,$,$); -#4702=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 37 15','Non Invasive Bi Level Ventilator Units',#4699,$,$); -#4703=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 37 17','Transport Ventilators',#4699,$,$); -#4704=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 37 19','Adult Intensive Care Ventilators',#4699,$,$); -#4705=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 37 21','High Frequency Ventilators',#4699,$,$); -#4706=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 37 23','Home Care Ventilators',#4699,$,$); -#4707=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 37 25','Positive End Expiratory Pressure Ventilator Valves',#4699,$,$); -#4708=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 37 27','Ventilator Water Traps',#4699,$,$); -#4709=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 37 29','Ventilator Gas Sampling Ports',#4699,$,$); -#4710=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 37 31','Ventilator Heat Exchangers',#4699,$,$); -#4711=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 37 33','Ventilator Moisture Exchangers',#4699,$,$); -#4712=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 39','Resuscitation Products',#4636,$,$); -#4713=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 39 11','Manual Resuscitators',#4712,$,$); -#4714=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 39 13','Pneumatic Resuscitators',#4712,$,$); -#4715=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 39 15','Electro Mechanical Resuscitators',#4712,$,$); -#4716=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 41','Lung Fluid Products',#4636,$,$); -#4717=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 41 11','Pleural Cavity Drainage Units',#4716,$,$); -#4718=IFCCLASSIFICATIONREFERENCE($,'23-25 11 15','Anesthesiology Prefabricated Structures',#4634,$,$); -#4719=IFCCLASSIFICATIONREFERENCE($,'23-25 11 15 11','Anesthesiology Gas Columns',#4718,$,$); -#4720=IFCCLASSIFICATIONREFERENCE($,'23-25 13 00','Audiology Products',#4633,$,$); -#4721=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11','Audiology Equipment',#4720,$,$); -#4722=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 11','Audiometers',#4721,$,$); -#4723=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 11 11','Diagnostic Audiometers',#4722,$,$); -#4724=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 11 13','Group Screening Audiometers',#4722,$,$); -#4725=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 11 15','Middle Ear Impedance Diagnostic Audiometers',#4722,$,$); -#4726=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 13','Audiometric Bone Vibrators',#4721,$,$); -#4727=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 15','Middle Ear Analyzers',#4721,$,$); -#4728=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 17','Auditory Function Screening Units',#4721,$,$); -#4729=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 19','Auditory Test Graphic Recorders',#4721,$,$); -#4730=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 21','Auditory Analyzers',#4721,$,$); -#4731=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 21 11','Evoked Potential Auditory Analyzers',#4730,$,$); -#4732=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 23','Ear Fenestrometers',#4721,$,$); -#4733=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 25','Electrocochleographs',#4721,$,$); -#4734=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 27','Hearing Aides',#4721,$,$); -#4735=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 29','Hearing Aid Analyzers',#4721,$,$); -#4736=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 31','Tinnitus Analyzers',#4721,$,$); -#4737=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 33','Toynbee Diagnostic Tubes',#4721,$,$); -#4738=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 35','Tympanometers',#4721,$,$); -#4739=IFCCLASSIFICATIONREFERENCE($,'23-25 13 13','Audiology Prefabricated Structures',#4720,$,$); -#4740=IFCCLASSIFICATIONREFERENCE($,'23-25 13 13 11','Audio Booths',#4739,$,$); -#4741=IFCCLASSIFICATIONREFERENCE($,'23-25 13 13 13','Double Wall Audio Booths',#4739,$,$); -#4742=IFCCLASSIFICATIONREFERENCE($,'23-25 13 13 13 11','Definitive Test Double Wall Audio Booths',#4741,$,$); -#4743=IFCCLASSIFICATIONREFERENCE($,'23-25 13 13 15','Single Wall Audio Booths',#4739,$,$); -#4744=IFCCLASSIFICATIONREFERENCE($,'23-25 13 13 17','Acoustic Hearing Test Chambers',#4739,$,$); -#4745=IFCCLASSIFICATIONREFERENCE($,'23-25 15 00','Autopsy and Postmortem Products',#4633,$,$); -#4746=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11','Autopsy and Postmortem Furnishings',#4745,$,$); -#4747=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 11','Postmortem Refrigerators and Freezers',#4746,$,$); -#4748=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 11 11','Cadaver Cabinet Refrigerators',#4747,$,$); -#4749=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 11 13','Cadaver Freezers',#4747,$,$); -#4750=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 11 15','Cadaver Refrigerated Rooms',#4747,$,$); -#4751=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 11 17','Cadaver Refrigerators',#4747,$,$); -#4752=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 11 19','Cadaver Walk In Refrigerators',#4747,$,$); -#4753=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 13','Autopsy Tables',#4746,$,$); -#4754=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 13 11','Autopsy Body Boards',#4753,$,$); -#4755=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 13 13','Autopsy Dissecting Tank Tables',#4753,$,$); -#4756=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 13 15','Autopsy Head Rests',#4753,$,$); -#4757=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 13 17','Autopsy Sinks',#4753,$,$); -#4758=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 13 19','Mobile Autopsy Tables',#4753,$,$); -#4759=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 13 21','Stationary Autopsy Tables',#4753,$,$); -#4760=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 15','Embalming Sinks',#4746,$,$); -#4761=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13','Autopsy and Postmortem Equipment',#4745,$,$); -#4762=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 11','Cadaver Lifts',#4761,$,$); -#4763=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 11 11','Cadaver Electric Lifts',#4762,$,$); -#4764=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 11 13','Cadaver Hydraulic Lifts',#4762,$,$); -#4765=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 11 15','Cadaver Scissor Lift Trolleys',#4762,$,$); -#4766=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 13','Autopsy Equipment',#4761,$,$); -#4767=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 13 11','Autopsy Fluid Collection Vacuum Aspirators',#4766,$,$); -#4768=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 13 13','Autopsy Hanging Scales',#4766,$,$); -#4769=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 13 15','Autopsy Saws',#4766,$,$); -#4770=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 13 17','Bone Dust Collectors',#4766,$,$); -#4771=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 15','Cadaver Transport And Storage Products',#4761,$,$); -#4772=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 15 11','Autopsy Carts',#4771,$,$); -#4773=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 15 13','Body Transport Containers',#4771,$,$); -#4774=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 15 15','Cadaver Carriers',#4771,$,$); -#4775=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 15 17','Cadaver Lifter Or Transfer Devices',#4771,$,$); -#4776=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 15 19','Cadaver Storage Cabinets',#4771,$,$); -#4777=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 15 21','Cadaver Storage Racks',#4771,$,$); -#4778=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 15 23','Cadaver Trays',#4771,$,$); -#4779=IFCCLASSIFICATIONREFERENCE($,'23-25 15 15','Autopsy and Postmortem Prefabricated Structures',#4745,$,$); -#4780=IFCCLASSIFICATIONREFERENCE($,'23-25 15 15 11','Autopsy Workstations',#4779,$,$); -#4781=IFCCLASSIFICATIONREFERENCE($,'23-25 15 15 11 11','Autopsy Grossing Workstations',#4780,$,$); -#4782=IFCCLASSIFICATIONREFERENCE($,'23-25 15 15 11 13','Embalming Workstations',#4780,$,$); -#4783=IFCCLASSIFICATIONREFERENCE($,'23-25 15 15 11 15','Autopsy Down Draft Workstations',#4780,$,$); -#4784=IFCCLASSIFICATIONREFERENCE($,'23-25 15 17','Autopsy and Postmortem Devices',#4745,$,$); -#4785=IFCCLASSIFICATIONREFERENCE($,'23-25 17 00','Dental Products',#4633,$,$); -#4786=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11','Dental Furnishings',#4785,$,$); -#4787=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 11','Dental Cabinets',#4786,$,$); -#4788=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 11 11','Mobile Dental Cabinets',#4787,$,$); -#4789=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 11 13','Dental Operating Stool',#4787,$,$); -#4790=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 13','Dental Examination Chairs',#4786,$,$); -#4791=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 15','Dental Stools',#4786,$,$); -#4792=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 17','Dental Cabinets',#4786,$,$); -#4793=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 19','Dental Tables',#4786,$,$); -#4794=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 21','Dental Combination Furniture Sets',#4786,$,$); -#4795=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 23','Dental Impression Water Baths',#4786,$,$); -#4796=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 25','Dental Lighting Products',#4786,$,$); -#4797=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 25 11','Dental Fiber Optic Lights',#4796,$,$); -#4798=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 25 13','Dental Operating Illumination Sets',#4796,$,$); -#4799=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 25 15','Dental Operating Light Tripods',#4796,$,$); -#4800=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 25 17','General Dental Lights',#4796,$,$); -#4801=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13','Dental Equipment',#4785,$,$); -#4802=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 11','Dental Furnaces',#4801,$,$); -#4803=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 11 11','Dental Burnout Laboratory Furnaces',#4802,$,$); -#4804=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 11 13','Porcelain Glazing Laboratory Furnaces',#4802,$,$); -#4805=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 11 15','Vacuum Porcelain Furnaces',#4802,$,$); -#4806=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 13','Dental Specialized Hoods',#4801,$,$); -#4807=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 13 11','Dental Acrylic Floor Standing Fume Hoods',#4806,$,$); -#4808=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 13 13','Dental Fishmouth Hoods',#4806,$,$); -#4809=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 13 15','Dental Splash Hoods',#4806,$,$); -#4810=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 13 17','Dental Splash Hoods with Shield',#4806,$,$); -#4811=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15','Dental Procedure Products',#4801,$,$); -#4812=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 01','Calcium Hydroxide Placement Tools',#4811,$,$); -#4813=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 03','Composite Placement Tools',#4811,$,$); -#4814=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 05','Crown Or Bridge Removers',#4811,$,$); -#4815=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 07','Dental Amalgam Carvers',#4811,$,$); -#4816=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 09','Dental Amalgamator',#4811,$,$); -#4817=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 11','Dental Anesthesia Sets',#4811,$,$); -#4818=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 13','Dental Bur Holders',#4811,$,$); -#4819=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 15','Dental Burnishers',#4811,$,$); -#4820=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 17','Dental Burs',#4811,$,$); -#4821=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 19','Dental Calipers',#4811,$,$); -#4822=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 21','Dental Cryosurgical Units',#4811,$,$); -#4823=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 23','Dental Dehydrators',#4811,$,$); -#4824=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 25','Dental Depth Gauges',#4811,$,$); -#4825=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 27','Dental Drills',#4811,$,$); -#4826=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 29','Dental Elevators',#4811,$,$); -#4827=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 31','Dental Excavators',#4811,$,$); -#4828=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 33','Dental Expanders',#4811,$,$); -#4829=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 35','Dental Filler Contouring Instruments',#4811,$,$); -#4830=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 37','Dental Fracture Detecting Tools',#4811,$,$); -#4831=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 39','Dental Gages',#4811,$,$); -#4832=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 41','Dental Guides',#4811,$,$); -#4833=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 43','Dental Heat Carriers',#4811,$,$); -#4834=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 45','Dental Hygiene Instruments',#4811,$,$); -#4835=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 47','Dental Instrument Cassettes',#4811,$,$); -#4836=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 49','Dental Instrument Sharpening Equipment',#4811,$,$); -#4837=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 51','Dental Instrument Trays',#4811,$,$); -#4838=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 53','Dental Instruments Mats',#4811,$,$); -#4839=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 55','Dental Lasers',#4811,$,$); -#4840=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 57','Dental Mallets',#4811,$,$); -#4841=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 59','Dental Mixing Slabs',#4811,$,$); -#4842=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 61','Dental Nippers',#4811,$,$); -#4843=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 63','Dental Operative Brushes',#4811,$,$); -#4844=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 65','Dental Oral Suction Devices',#4811,$,$); -#4845=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 67','Dental Pin Benders',#4811,$,$); -#4846=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 69','Dental Pin Drivers',#4811,$,$); -#4847=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 71','Dental Placement Instruments',#4811,$,$); -#4848=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 73','Dental Pulp Testers',#4811,$,$); -#4849=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 75','Dental Reamers',#4811,$,$); -#4850=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 77','Dental Retraction Cord Packing Instruments',#4811,$,$); -#4851=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 79','Dental Retractors',#4811,$,$); -#4852=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 81','Dental Saliva Ejectors',#4811,$,$); -#4853=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 83','Dental Scalers',#4811,$,$); -#4854=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 85','Dental Spreaders',#4811,$,$); -#4855=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 87','Dental Tooth Separators',#4811,$,$); -#4856=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 89','Dental Vitality Testers',#4811,$,$); -#4857=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 91','Dentoscopes',#4811,$,$); -#4858=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 93','Intraoral Lights',#4811,$,$); -#4859=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 95','Pneumatic Dental Chisels',#4811,$,$); -#4860=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 97','Temporomandibular Joint (TMJ) Dental Videoscopes',#4811,$,$); -#4861=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 17','Dental Tanks',#4801,$,$); -#4862=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 17 11','Dental Blow Out Tanks',#4861,$,$); -#4863=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 17 13','Dental Curing Tanks',#4861,$,$); -#4864=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 17 15','Dental Washout Blow Out Tanks',#4861,$,$); -#4865=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 19','Dental Polishing and Grinding Machines',#4801,$,$); -#4866=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 19 11','Dental Combination Grinding and Polishing Machines',#4865,$,$); -#4867=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 19 13','Dental Grinding Machines',#4865,$,$); -#4868=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 19 15','Dental Polishing Machines',#4865,$,$); -#4869=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21','Dental Imaging Products',#4801,$,$); -#4870=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21 11','Cephalometric Radiographic Fluoroscopic Units',#4869,$,$); -#4871=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21 13','Dental Film Processors',#4869,$,$); -#4872=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21 15','Dental Radioactive Tracers',#4869,$,$); -#4873=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21 17','Dental Radiographic Fluoroscopic Units',#4869,$,$); -#4874=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21 17 11','Panographic Cephalo Dental Radiographic Fluoroscopic Units',#4873,$,$); -#4875=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21 17 13','Panographic Dental Radiographic Fluoroscopic Units',#4873,$,$); -#4876=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21 19','Dental Radiography Film Analyzers',#4869,$,$); -#4877=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21 21','Dental Radiology Film Hangers',#4869,$,$); -#4878=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21 23','Dental Radiology Film Holders',#4869,$,$); -#4879=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21 25','Dental Radiology Film Mounts',#4869,$,$); -#4880=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21 27','Dental X Ray Duplicators',#4869,$,$); -#4881=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21 29','Dental X Ray Units',#4869,$,$); -#4882=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21 31','Dental X Ray Viewers',#4869,$,$); -#4883=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 23','Dental Sterilization Products',#4801,$,$); -#4884=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 23 11','Dental Steam Cleaners',#4883,$,$); -#4885=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25','Dental Laboratory Products',#4801,$,$); -#4886=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 11','Dental Air Abrasion Units',#4885,$,$); -#4887=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 13','Dental Burners',#4885,$,$); -#4888=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 15','Dental Casting Machines',#4885,$,$); -#4889=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 17','Dental Curing Units',#4885,$,$); -#4890=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 17 11','2 Stage Dental Curing Units',#4889,$,$); -#4891=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 17 13','3 Stage Dental Curing Units',#4889,$,$); -#4892=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 19','Dental Dust Collectors',#4885,$,$); -#4893=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 21','Dental Gold Platers',#4885,$,$); -#4894=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 23','Dental Lathes',#4885,$,$); -#4895=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 25','Dental Model Trimmers',#4885,$,$); -#4896=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 27','Dental Models',#4885,$,$); -#4897=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 29','Dental Plaster Traps',#4885,$,$); -#4898=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 31','Dental Resin Curing Units',#4885,$,$); -#4899=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 31 11','Dental Visible Light Resin Curing Units',#4898,$,$); -#4900=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 33','Dental Resins Processing Units',#4885,$,$); -#4901=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 35','Dental Sandblasters',#4885,$,$); -#4902=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 37','Dental Soldering Machines',#4885,$,$); -#4903=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 39','Dental Torches',#4885,$,$); -#4904=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 41','Dental Vacuum Units',#4885,$,$); -#4905=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 43','Dental Vibrators',#4885,$,$); -#4906=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 45','Dental Waxing Units',#4885,$,$); -#4907=IFCCLASSIFICATIONREFERENCE($,'23-25 17 15','Dental Prefabricated Structures',#4785,$,$); -#4908=IFCCLASSIFICATIONREFERENCE($,'23-25 17 15 11','Dental Lab Workcenters',#4907,$,$); -#4909=IFCCLASSIFICATIONREFERENCE($,'23-25 17 15 11 11','Dental Lab Die Trimming Workcenters',#4908,$,$); -#4910=IFCCLASSIFICATIONREFERENCE($,'23-25 17 15 11 13','Dental Lab Equipment Workcenters',#4908,$,$); -#4911=IFCCLASSIFICATIONREFERENCE($,'23-25 17 15 11 15','Dental Lab Metal Grinding Workcenters',#4908,$,$); -#4912=IFCCLASSIFICATIONREFERENCE($,'23-25 17 15 11 17','Dental Lab Microblasting Workcenters',#4908,$,$); -#4913=IFCCLASSIFICATIONREFERENCE($,'23-25 17 15 11 19','Dental Lab Plaster Workcenters',#4908,$,$); -#4914=IFCCLASSIFICATIONREFERENCE($,'23-25 17 15 11 21','Dental Lab Polishing Workcenters',#4908,$,$); -#4915=IFCCLASSIFICATIONREFERENCE($,'23-25 17 15 11 23','Dental Lab Surveying and Milling Workcenters',#4908,$,$); -#4916=IFCCLASSIFICATIONREFERENCE($,'23-25 19 00','Dermatology Products',#4633,$,$); -#4917=IFCCLASSIFICATIONREFERENCE($,'23-25 19 11','Dermatology Furnishings',#4916,$,$); -#4918=IFCCLASSIFICATIONREFERENCE($,'23-25 19 13','Dermatology Equipment',#4916,$,$); -#4919=IFCCLASSIFICATIONREFERENCE($,'23-25 19 13 11','Phototherapy Products',#4918,$,$); -#4920=IFCCLASSIFICATIONREFERENCE($,'23-25 19 13 11 11','Phototherapy Air Circulators',#4919,$,$); -#4921=IFCCLASSIFICATIONREFERENCE($,'23-25 19 13 11 13','Phototherapy Blankets',#4919,$,$); -#4922=IFCCLASSIFICATIONREFERENCE($,'23-25 19 13 11 15','Phototherapy Light Mats',#4919,$,$); -#4923=IFCCLASSIFICATIONREFERENCE($,'23-25 19 13 11 17','Phototherapy Patient Protection Devices',#4919,$,$); -#4924=IFCCLASSIFICATIONREFERENCE($,'23-25 19 13 11 19','Phototherapy Power Units',#4919,$,$); -#4925=IFCCLASSIFICATIONREFERENCE($,'23-25 19 13 11 21','Phototherapy Warmer Beds',#4919,$,$); -#4926=IFCCLASSIFICATIONREFERENCE($,'23-25 19 15','Dermatology Prefabricated Structures',#4916,$,$); -#4927=IFCCLASSIFICATIONREFERENCE($,'23-25 19 15 11','Ultraviolet Treatment Booths',#4926,$,$); -#4928=IFCCLASSIFICATIONREFERENCE($,'23-25 19 15 13','Hand and Foot Ultraviolet Treatment Booths',#4926,$,$); -#4929=IFCCLASSIFICATIONREFERENCE($,'23-25 19 17','Dermatology Devices',#4916,$,$); -#4930=IFCCLASSIFICATIONREFERENCE($,'23-25 21 00','Emergency Trauma and Intensive Care Products',#4633,$,$); -#4931=IFCCLASSIFICATIONREFERENCE($,'23-25 21 11','Emergency Trauma and Intensive Furnishings',#4930,$,$); -#4932=IFCCLASSIFICATIONREFERENCE($,'23-25 21 11 11','Catheter Storage Cabinets',#4931,$,$); -#4933=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13','Emergency Trauma and Intensive Equipment',#4930,$,$); -#4934=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 11','Emergency Carts',#4933,$,$); -#4935=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 13','Emergency Transportation Products',#4933,$,$); -#4936=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 13 11','Air Evacuation Stretchers',#4935,$,$); -#4937=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 13 13','Ambulance Cots',#4935,$,$); -#4938=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 13 15','Anti Shock Garments',#4935,$,$); -#4939=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 13 17','Basket Stretchers',#4935,$,$); -#4940=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 13 19','Scoop Stretchers',#4935,$,$); -#4941=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 13 21','Spine Boards',#4935,$,$); -#4942=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 13 23','Water Rescue Tubes',#4935,$,$); -#4943=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 15','Emergency Airway Management Products',#4933,$,$); -#4944=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 15 11','Emergency Laryngoscope Kits',#4943,$,$); -#4945=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 15 13','Emergency Oropharyngeal Airway Devices',#4943,$,$); -#4946=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 15 15','Emergency Suction Units',#4943,$,$); -#4947=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 15 17','Emergency Tracheal Tube Kits',#4943,$,$); -#4948=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 17','Emergency Kits',#4933,$,$); -#4949=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 17 11','Emergency Dental Kits',#4948,$,$); -#4950=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 17 13','Emergency First Aid Kits',#4948,$,$); -#4951=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 17 15','Emergency Fracture Kits',#4948,$,$); -#4952=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 17 17','Emergency Intravenous IV Kits',#4948,$,$); -#4953=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 17 19','Emergency Medical First Response Kits',#4948,$,$); -#4954=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 17 21','Emergency Medical Technician Kits',#4948,$,$); -#4955=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 17 23','Emergency Obstetrics Kits',#4948,$,$); -#4956=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 17 25','Emergency Resuscitation Kits',#4948,$,$); -#4957=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 17 27','Emergency Services Trauma Kits',#4948,$,$); -#4958=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 17 29','Emergency Ventriculostomy Kits',#4948,$,$); -#4959=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 19','Emergency Resuscitation Products',#4933,$,$); -#4960=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 19 11','Diefibrillators',#4959,$,$); -#4961=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 19 11 11','Acute Care Defibrillators',#4960,$,$); -#4962=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 19 11 13','Acute Care Defibrillator With Monitors',#4960,$,$); -#4963=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 19 11 15','Automatic Defibrillators',#4960,$,$); -#4964=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 19 11 17','Defibrillator with Cardioscopes',#4960,$,$); -#4965=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 19 11 19','Portable Defibrillators',#4960,$,$); -#4966=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 19 13','Defibrillator Analyzers',#4959,$,$); -#4967=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 19 15','Emergency Aspirators',#4959,$,$); -#4968=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 19 17','Emergency Resuscitators',#4959,$,$); -#4969=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 19 17 11','Emergency Manual Resuscitators',#4968,$,$); -#4970=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 19 17 13','Emergency Pulmonary Resuscitators',#4968,$,$); -#4971=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 19 17 15','Emergency Oxygen Powered Resuscitators',#4968,$,$); -#4972=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 21','Acute Care Monitoring Units',#4933,$,$); -#4973=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 21 11','Acute Care Fetal Monitoring Units',#4972,$,$); -#4974=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 21 13','Acute Care Maternal Monitoring Units',#4972,$,$); -#4975=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 21 15','Cardiac Output Monitoring Units',#4972,$,$); -#4976=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 21 17','Intracranial Pressure Monitoring Units',#4972,$,$); -#4977=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 21 19','Multiparameter Vital Sign Units',#4972,$,$); -#4978=IFCCLASSIFICATIONREFERENCE($,'23-25 21 15','Emergency Trauma and Intensive Prefabricated Structures',#4930,$,$); -#4979=IFCCLASSIFICATIONREFERENCE($,'23-25 21 15 11','Intensive Care Unit Prefabricated Service Columns',#4978,$,$); -#4980=IFCCLASSIFICATIONREFERENCE($,'23-25 21 15 13','Trauma Workcenters',#4978,$,$); -#4981=IFCCLASSIFICATIONREFERENCE($,'23-25 23 00','Endocrinology Products',#4633,$,$); -#4982=IFCCLASSIFICATIONREFERENCE($,'23-25 23 11','Endocrinology Furnishings',#4981,$,$); -#4983=IFCCLASSIFICATIONREFERENCE($,'23-25 23 11 11','Dialysis Chairs',#4982,$,$); -#4984=IFCCLASSIFICATIONREFERENCE($,'23-25 23 11 13','Dialysis Tables',#4982,$,$); -#4985=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13','Endocrinology Equipment',#4981,$,$); -#4986=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 11','Peritoneal Dialysis Products',#4985,$,$); -#4987=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 11 11','Continuous Ambulatory Peritoneal Dialysis Transfer Units',#4986,$,$); -#4988=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 11 13','Dialysis Boxes',#4986,$,$); -#4989=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 11 15','Pheresis Units',#4986,$,$); -#4990=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 11 17','Peritoneal Dialysis Units',#4986,$,$); -#4991=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 11 17 11','Hollow Peritoneal Dialysis Units',#4990,$,$); -#4992=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13','Hemodialysis Products',#4985,$,$); -#4993=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 11','Hemodialysis Blood Oxygen Demand Units',#4992,$,$); -#4994=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 13','Hemodialysis Conductivity Meters',#4992,$,$); -#4995=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 15','Hemodialysis Filters',#4992,$,$); -#4996=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 17','Hemodialysis Level Detectors',#4992,$,$); -#4997=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 19','Hemodialysis Pressure Pumps',#4992,$,$); -#4998=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 21','Hemodialysis Reprocessing Units',#4992,$,$); -#4999=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 23','Hemodialysis Tanks',#4992,$,$); -#5000=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 25','Hemodialysis Unit Arterial Pressure Monitors',#4992,$,$); -#5001=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 27','Hemodialysis Unit Blood Pumps',#4992,$,$); -#5002=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 29','Hemodialysis Unit Heparin Infusion Pumps',#4992,$,$); -#5003=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 31','Hemodialysis Unit Single Pass Converters',#4992,$,$); -#5004=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 33','Hemodialysis Unit Stands',#4992,$,$); -#5005=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 35','Hemodialysis Unit Temperature Monitors',#4992,$,$); -#5006=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 37','Hemodialysis Unit Test Equipment',#4992,$,$); -#5007=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 39','Hemodialysis Units',#4992,$,$); -#5008=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 41','Hemodialysis Warming Baths',#4992,$,$); -#5009=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 15','Continuous Renal Replacement Therapy Products',#4985,$,$); -#5010=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 15 11','Continuous Arteriovenous Dialysis Units',#5009,$,$); -#5011=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 15 13','Continuous Arteriovenous Hemofiltration Units',#5009,$,$); -#5012=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 15 15','Continuous Venovenous Hemodialysis Units',#5009,$,$); -#5013=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 15 17','Continuous Venovenous Hemofiltration Units',#5009,$,$); -#5014=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 15 19','Renal Dialysis Cartridge Flushing Units',#5009,$,$); -#5015=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 15 21','Slow Continuous Ultrafiltration Units',#5009,$,$); -#5016=IFCCLASSIFICATIONREFERENCE($,'23-25 23 15','Endocrinology Prefabricated Structures',#4981,$,$); -#5017=IFCCLASSIFICATIONREFERENCE($,'23-25 25 00','Gastroenterology and Hepatology Products',#4633,$,$); -#5018=IFCCLASSIFICATIONREFERENCE($,'23-25 25 11','Gastroenterology Furnishings',#5017,$,$); -#5019=IFCCLASSIFICATIONREFERENCE($,'23-25 25 11 11','Proctology Examination Tables',#5018,$,$); -#5020=IFCCLASSIFICATIONREFERENCE($,'23-25 25 11 13','Urological Procedure Table',#5018,$,$); -#5021=IFCCLASSIFICATIONREFERENCE($,'23-25 25 11 13 11','Endoscope Storage Cabinets',#5020,$,$); -#5022=IFCCLASSIFICATIONREFERENCE($,'23-25 25 11 13 13','Endoscope Wall Hangers',#5020,$,$); -#5023=IFCCLASSIFICATIONREFERENCE($,'23-25 25 11 13 15','Endoscopic Procedure Carts',#5020,$,$); -#5024=IFCCLASSIFICATIONREFERENCE($,'23-25 25 13','Gastroenterology Equipment',#5017,$,$); -#5025=IFCCLASSIFICATIONREFERENCE($,'23-25 25 15','Gastroenterology Prefabricated Structures',#5017,$,$); -#5026=IFCCLASSIFICATIONREFERENCE($,'23-25 25 17','Gastroenterology Devices',#5017,$,$); -#5027=IFCCLASSIFICATIONREFERENCE($,'23-25 27 00','General Internal Medicine Products',#4633,$,$); -#5028=IFCCLASSIFICATIONREFERENCE($,'23-25 27 11','General Internal Medicine Furnishings',#5027,$,$); -#5029=IFCCLASSIFICATIONREFERENCE($,'23-25 27 11 11','Intravenous Transport Products',#5028,$,$); -#5030=IFCCLASSIFICATIONREFERENCE($,'23-25 27 11 11 11','Intravenous Equipment Hangers',#5029,$,$); -#5031=IFCCLASSIFICATIONREFERENCE($,'23-25 27 11 11 13','Intravenous Infusion Gravity Systems Mounted Racks',#5029,$,$); -#5032=IFCCLASSIFICATIONREFERENCE($,'23-25 27 11 11 15','Intravenous Infusion Gravity Systems Mounted Tracks',#5029,$,$); -#5033=IFCCLASSIFICATIONREFERENCE($,'23-25 27 11 11 17','Intravenous Line Poles',#5029,$,$); -#5034=IFCCLASSIFICATIONREFERENCE($,'23-25 27 11 11 19','Intravenous Line Stands',#5029,$,$); -#5035=IFCCLASSIFICATIONREFERENCE($,'23-25 27 11 11 21','Intravenous Wheelchair Poles',#5029,$,$); -#5036=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13','General Internal Medicine Equipment',#5027,$,$); -#5037=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 11','Endoscopy Carts',#5036,$,$); -#5038=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 11 11','Fiberoptic Endoscopy Carts',#5037,$,$); -#5039=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 11 11 11','Basic Fiberoptic Endoscopy Carts',#5038,$,$); -#5040=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 11 11 13','Fiberoptic Endoscopy Carts With Video Accessories',#5038,$,$); -#5041=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 11 11 15','Fiberoptic Endoscopy Carts With Video Accessories And Information Management',#5038,$,$); -#5042=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 11 13','Video Endoscopy Carts',#5037,$,$); -#5043=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 11 13 11','Video Endoscopy Carts CCD Scope And Information Management',#5042,$,$); -#5044=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 13','Intravenous Pump Products',#5036,$,$); -#5045=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 13 11','General Use Intravenous Pumps',#5044,$,$); -#5046=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 13 13','Intravenous Infusion Pump Analyzers',#5044,$,$); -#5047=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 13 15','Intravenous Infusion Pump Sensors',#5044,$,$); -#5048=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 13 17','Intravenous Infusion Pump Transducers',#5044,$,$); -#5049=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 13 19','Intravenous Syringe Pumps',#5044,$,$); -#5050=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 13 21','Multichannel Intravenous Pumps',#5044,$,$); -#5051=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 15','Urological Products',#5036,$,$); -#5052=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 15 11','Cystometry Transducers',#5051,$,$); -#5053=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 15 13','Urethral Sound Sets',#5051,$,$); -#5054=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 15 15','Urethral Stone Remover Sets',#5051,$,$); -#5055=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 15 17','Urodynamic Catheters',#5051,$,$); -#5056=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 15 19','Urological Percolators',#5051,$,$); -#5057=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17','Endoscopes Products',#5036,$,$); -#5058=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 11','Rigid Endoscopes',#5057,$,$); -#5059=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 13','Flexible Endoscopes',#5057,$,$); -#5060=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 15','Cystourethroscopes',#5057,$,$); -#5061=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 17','Resectoscopes',#5057,$,$); -#5062=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 19','Laparoscopes',#5057,$,$); -#5063=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 21','Laparoscopic Telescopes',#5057,$,$); -#5064=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 23','Cystoscopes',#5057,$,$); -#5065=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 25','Endoscopic Sphincterotomes',#5057,$,$); -#5066=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 27','Duodenoscopes',#5057,$,$); -#5067=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 27 11','Combination Duodenoscope and Choledochoscopes',#5066,$,$); -#5068=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 27 13','Therapeutic Duodenoscopes',#5066,$,$); -#5069=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 27 15','Fiberoptic Therapeutic Duodenoscopes',#5066,$,$); -#5070=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 27 17','Video Therapeutic Duodenoscopes',#5066,$,$); -#5071=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 29','Esophagoscopes',#5057,$,$); -#5072=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 31','Endoscopic Equipment Sets',#5057,$,$); -#5073=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 33','Endoscopic Heater Probe Units',#5057,$,$); -#5074=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 35','Endoscopic Imaging Equipment',#5057,$,$); -#5075=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 37','Endoscopic Insufflation Units',#5057,$,$); -#5076=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 39','Endoscopic Distention Units',#5057,$,$); -#5077=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 41','Endoscopic Printers',#5057,$,$); -#5078=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 43','Endoscopic Video Cameras',#5057,$,$); -#5079=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 45','Endoscopic Recorders',#5057,$,$); -#5080=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 47','Enteroscopes',#5057,$,$); -#5081=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 47 11','Therapeutic Fiberoptic Enteroscopes',#5080,$,$); -#5082=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 47 13','Therapeutic Video Enteroscopes',#5080,$,$); -#5083=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 19','Gastroscope Products',#5036,$,$); -#5084=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 19 11','Therapeutic Fiberoptic Gastroscopes',#5083,$,$); -#5085=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 19 13','Therapeutic Video Gastroscopes',#5083,$,$); -#5086=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 21','Sigmoidoscope Products',#5036,$,$); -#5087=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 21 11','Therapeutic Sigmoidoscopes',#5086,$,$); -#5088=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 21 13','Fiberoptic Therapeutic Sigmoidoscopes',#5086,$,$); -#5089=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 21 15','Video Therapeutic Sigmoidoscopes',#5086,$,$); -#5090=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 23','Colonoscopy Products',#5036,$,$); -#5091=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 23 11','Mobile Colonoscope System With Accessories',#5090,$,$); -#5092=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 23 13','Therapeutic Colonoscopes',#5090,$,$); -#5093=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 23 13 11','Fiberoptic Therapeutic Colonoscopes',#5092,$,$); -#5094=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 23 13 13','Video Therapeutic Colonoscopes',#5092,$,$); -#5095=IFCCLASSIFICATIONREFERENCE($,'23-25 27 15','General Internal Medicine Prefabricated Structures',#5027,$,$); -#5096=IFCCLASSIFICATIONREFERENCE($,'23-25 29 00','Therapeutic and Physical Therapy Products',#4633,$,$); -#5097=IFCCLASSIFICATIONREFERENCE($,'23-25 29 11','Therapeutic and Physical Therapy Furnishings',#5096,$,$); -#5098=IFCCLASSIFICATIONREFERENCE($,'23-25 29 11 11','Therapeutic Baths',#5097,$,$); -#5099=IFCCLASSIFICATIONREFERENCE($,'23-25 29 11 11 11','Hydrotherapy Baths',#5098,$,$); -#5100=IFCCLASSIFICATIONREFERENCE($,'23-25 29 11 11 11 11','Body Hydrotherapy Baths',#5099,$,$); -#5101=IFCCLASSIFICATIONREFERENCE($,'23-25 29 11 11 11 13','Burn Hydrotherapy Baths',#5099,$,$); -#5102=IFCCLASSIFICATIONREFERENCE($,'23-25 29 11 11 11 15','Burn Hydrotherapy With Lift Baths',#5099,$,$); -#5103=IFCCLASSIFICATIONREFERENCE($,'23-25 29 11 11 11 17','Hydrotherapy With Elevating Tub Baths',#5099,$,$); -#5104=IFCCLASSIFICATIONREFERENCE($,'23-25 29 11 11 11 19','Sitting Hydrotherapy Baths',#5099,$,$); -#5105=IFCCLASSIFICATIONREFERENCE($,'23-25 29 11 11 13','Therapeutic Refrigerated Circulating Water Baths',#5098,$,$); -#5106=IFCCLASSIFICATIONREFERENCE($,'23-25 29 11 13','Therapeutic Tables',#5097,$,$); -#5107=IFCCLASSIFICATIONREFERENCE($,'23-25 29 11 13 11','Chiropractic Tables',#5106,$,$); -#5108=IFCCLASSIFICATIONREFERENCE($,'23-25 29 11 13 13','Therapeutic Massage Tables',#5106,$,$); -#5109=IFCCLASSIFICATIONREFERENCE($,'23-25 29 11 13 15','Traction Physical Therapy Tables',#5106,$,$); -#5110=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13','Therapeutic and Physical Therapy Equipment',#5096,$,$); -#5111=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 11','Physical Therapy Traction Equipment',#5110,$,$); -#5112=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 11 11','Traction Appliances Carts',#5111,$,$); -#5113=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13','Therapeutic Exercise Equipment',#5110,$,$); -#5114=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 11','Balance Beams',#5113,$,$); -#5115=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 13','Therapeutic Exercise Balance Boards',#5113,$,$); -#5116=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 15','Therapeutic Exercise Balance Bolsters',#5113,$,$); -#5117=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 17','Therapeutic Exercise Balance Rockers',#5113,$,$); -#5118=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 19','Therapeutic Exercise Climbing Equipment',#5113,$,$); -#5119=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 21','Therapeutic Exercise Continuous Passive Motion CPM Equipment',#5113,$,$); -#5120=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 23','Therapeutic Exercise Skates',#5113,$,$); -#5121=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 25','Therapeutic Exercise Free Weights',#5113,$,$); -#5122=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 27','Therapeutic Lung Exercisers',#5113,$,$); -#5123=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 29','Therapeutic Exercise Mats',#5113,$,$); -#5124=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 31','Therapeutic Exercise Platforms',#5113,$,$); -#5125=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 33','Therapeutic Exercise Pulleys',#5113,$,$); -#5126=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 35','Therapeutic Exercise Resistive Equipment',#5113,$,$); -#5127=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 37','Therapeutic Exercise Skateboards',#5113,$,$); -#5128=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 39','Therapeutic Exercise Therapeutic Balls',#5113,$,$); -#5129=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 41','Therapeutic Exercise Treadmills',#5113,$,$); -#5130=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 43','Therapeutic Exercise Vestibular Motion Equipment',#5113,$,$); -#5131=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 45','Therapeutic Exercise Weight Belts',#5113,$,$); -#5132=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 47','Therapeutic Exercise Weight Machines',#5113,$,$); -#5133=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 49','Therapeutic Exercise Wrist Exercisers',#5113,$,$); -#5134=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 15','Gait Training Products',#5110,$,$); -#5135=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 15 11','Gait Training Bars',#5134,$,$); -#5136=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 15 13','Gait Training Bikes',#5134,$,$); -#5137=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 15 15','Gait Training Parallel Bars',#5134,$,$); -#5138=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 15 17','Gait Training Ramps',#5134,$,$); -#5139=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 15 19','Gait Training Stairs',#5134,$,$); -#5140=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 15 21','Gait Training Walkers',#5134,$,$); -#5141=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 17','Electrotherapy Equipment',#5110,$,$); -#5142=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 17 11','Electrotherapy Combination Units',#5141,$,$); -#5143=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 17 13','Galvanic Stimulators',#5141,$,$); -#5144=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 17 15','Faradic Stimulators',#5141,$,$); -#5145=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 17 17','Neuromuscular Stimulators',#5141,$,$); -#5146=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 17 17 11','Multi Channel Neuromuscular Stimulators',#5145,$,$); -#5147=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 17 17 13','interferential Neuromuscular Stimulators',#5145,$,$); -#5148=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 17 17 15','Portable Neuromuscular Stimulators',#5145,$,$); -#5149=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 17 19','Therapeutic Short Wave Diathermy Units',#5141,$,$); -#5150=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 17 21','Transcutaneous Electric Nerve Stimulation Units',#5141,$,$); -#5151=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 19','Heat Cold Therapy Products',#5110,$,$); -#5152=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 19 11','Therapeutic Cold Storage Chilling Units',#5151,$,$); -#5153=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 19 13','Therapeutic Heat Lamps',#5151,$,$); -#5154=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 19 15','Therapeutic Hydrocollators',#5151,$,$); -#5155=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 19 17','Therapeutic Combination Heating Cooling Units',#5151,$,$); -#5156=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 19 19','Therapeutic Cooling Blankets',#5151,$,$); -#5157=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 19 21','Therapeutic Cooling Drapes',#5151,$,$); -#5158=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 19 23','Therapeutic Cooling Units',#5151,$,$); -#5159=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 19 25','Therapeutic Cryo Compression Equipment',#5151,$,$); -#5160=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 19 27','Therapeutic Heating Blankets',#5151,$,$); -#5161=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 19 29','Therapeutic Heating Drapes',#5151,$,$); -#5162=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 19 31','Therapeutic Heating Units',#5151,$,$); -#5163=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 19 33','Therapeutic Paraffin Baths',#5151,$,$); -#5164=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 21','Hydrotherapy Products',#5110,$,$); -#5165=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 21 11','Extremity Hydrotherapy Baths',#5164,$,$); -#5166=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 21 13','Extremity Hydrotherapy Tanks',#5164,$,$); -#5167=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 21 15','Full Body Immersion Hydrotherapy Baths',#5164,$,$); -#5168=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 21 17','Full Body Immersion Hydrotherapy Tanks',#5164,$,$); -#5169=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 21 19','Hydrotherapy Bath Chairs',#5164,$,$); -#5170=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 23','Hypothermia and Hyperthermia Units',#5110,$,$); -#5171=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 23 11','Combination Hyperthermia and Hypothermia Units',#5170,$,$); -#5172=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 23 13','Hyperthermia Units',#5170,$,$); -#5173=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 23 15','Hypothermia Units',#5170,$,$); -#5174=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 23 17','Mobile Combination Hyperthermia and Hypothermia Units',#5170,$,$); -#5175=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 23 19','Mobile Hyperthermia Units',#5170,$,$); -#5176=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 23 21','Mobile Hypothermia Units',#5170,$,$); -#5177=IFCCLASSIFICATIONREFERENCE($,'23-25 29 15','Health Exercise and Physical Therapy Prefabricated Structures',#5096,$,$); -#5178=IFCCLASSIFICATIONREFERENCE($,'23-25 29 15 11','Nourishment Stations',#5177,$,$); -#5179=IFCCLASSIFICATIONREFERENCE($,'23-25 31 00','Hematology Products',#4633,$,$); -#5180=IFCCLASSIFICATIONREFERENCE($,'23-25 31 11','Hematology Furnishings',#5179,$,$); -#5181=IFCCLASSIFICATIONREFERENCE($,'23-25 31 11 11','Blood Refrigerators and Freezers',#5180,$,$); -#5182=IFCCLASSIFICATIONREFERENCE($,'23-25 31 11 11 11','Blood Bank Refrigerators',#5181,$,$); -#5183=IFCCLASSIFICATIONREFERENCE($,'23-25 31 11 11 13','Blood Freezers',#5181,$,$); -#5184=IFCCLASSIFICATIONREFERENCE($,'23-25 31 11 11 13 11','Double Compartment Blood Freezers',#5183,$,$); -#5185=IFCCLASSIFICATIONREFERENCE($,'23-25 31 11 11 13 13','Blood Plasma Freezers',#5183,$,$); -#5186=IFCCLASSIFICATIONREFERENCE($,'23-25 31 11 11 15','Dry Tissue Freezers',#5181,$,$); -#5187=IFCCLASSIFICATIONREFERENCE($,'23-25 31 11 11 17','Plasma Storage Freezers',#5181,$,$); -#5188=IFCCLASSIFICATIONREFERENCE($,'23-25 31 11 13','Hematology Baths',#5180,$,$); -#5189=IFCCLASSIFICATIONREFERENCE($,'23-25 31 11 13 11','Serology Water Baths',#5188,$,$); -#5190=IFCCLASSIFICATIONREFERENCE($,'23-25 31 11 13 13','Tissue Processing Water Baths',#5188,$,$); -#5191=IFCCLASSIFICATIONREFERENCE($,'23-25 31 11 15','Hematology Cabinets',#5180,$,$); -#5192=IFCCLASSIFICATIONREFERENCE($,'23-25 31 11 15 11','Paraffin Block Cabinets',#5191,$,$); -#5193=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13','Hematology Equipment',#5179,$,$); -#5194=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13 11','Hematology Analyzers',#5193,$,$); -#5195=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13 11 11','Blood Lead Analyzers',#5194,$,$); -#5196=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13 11 13','BUN Analyzers',#5194,$,$); -#5197=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13 11 13 11','Discrete BUN Analyzers',#5196,$,$); -#5198=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13 11 15','PH Blood Gas Analyzers',#5194,$,$); -#5199=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13 11 17','Blood Typing Centrifuges',#5194,$,$); -#5200=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13 13','Blood And Transfusion Products',#5193,$,$); -#5201=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13 13 11','Blood Conservation Equipment',#5200,$,$); -#5202=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13 13 13','Blood Containers',#5200,$,$); -#5203=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13 13 15','Blood Transfusion Equipment',#5200,$,$); -#5204=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13 13 17','Blood Warming and Transfusion Equipment',#5200,$,$); -#5205=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13 13 19','Blood Warming Equipment',#5200,$,$); -#5206=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13 13 21','Blood Waste Collection Equipment',#5200,$,$); -#5207=IFCCLASSIFICATIONREFERENCE($,'23-25 31 15','Hematology Prefabricated Structures',#5179,$,$); -#5208=IFCCLASSIFICATIONREFERENCE($,'23-25 31 15 11','Blood Bank Workcenters',#5207,$,$); -#5209=IFCCLASSIFICATIONREFERENCE($,'23-25 31 15 13','Hematology Workcenters',#5207,$,$); -#5210=IFCCLASSIFICATIONREFERENCE($,'23-25 33 00','Medical Gas Products',#4633,$,$); -#5211=IFCCLASSIFICATIONREFERENCE($,'23-25 33 11','Medical Air Pressure Control Cabinets',#5210,$,$); -#5212=IFCCLASSIFICATIONREFERENCE($,'23-25 33 13','Medical Gas Alarm Modules',#5210,$,$); -#5213=IFCCLASSIFICATIONREFERENCE($,'23-25 33 15','Medical Gas Cylinder Carts',#5210,$,$); -#5214=IFCCLASSIFICATIONREFERENCE($,'23-25 33 17','Medical Gas Cylinder Stands',#5210,$,$); -#5215=IFCCLASSIFICATIONREFERENCE($,'23-25 33 19','Medical Gas Delivery Columns',#5210,$,$); -#5216=IFCCLASSIFICATIONREFERENCE($,'23-25 33 21','Medical Gas Filtering Equipment',#5210,$,$); -#5217=IFCCLASSIFICATIONREFERENCE($,'23-25 33 23','Medical Gas Manifolds',#5210,$,$); -#5218=IFCCLASSIFICATIONREFERENCE($,'23-25 33 25','Medical Gas Outlets',#5210,$,$); -#5219=IFCCLASSIFICATIONREFERENCE($,'23-25 33 27','Medical Gas Service Tracks',#5210,$,$); -#5220=IFCCLASSIFICATIONREFERENCE($,'23-25 33 29','Medical Gas Shutoff Valves',#5210,$,$); -#5221=IFCCLASSIFICATIONREFERENCE($,'23-25 33 31','Medical Gas Treatment Equipment',#5210,$,$); -#5222=IFCCLASSIFICATIONREFERENCE($,'23-25 33 33','Medical Gas Valve Boxes',#5210,$,$); -#5223=IFCCLASSIFICATIONREFERENCE($,'23-25 35 00','Nursing Products',#4633,$,$); -#5224=IFCCLASSIFICATIONREFERENCE($,'23-25 35 11','Nursing Furnishings',#5223,$,$); -#5225=IFCCLASSIFICATIONREFERENCE($,'23-25 35 11 11','Freestanding Nursing Table Bath and Showers',#5224,$,$); -#5226=IFCCLASSIFICATIONREFERENCE($,'23-25 35 13','Nursing Equipment',#5223,$,$); -#5227=IFCCLASSIFICATIONREFERENCE($,'23-25 35 13 11','Nursing Station Telecommunications Equipment',#5226,$,$); -#5228=IFCCLASSIFICATIONREFERENCE($,'23-25 35 13 11 11','Nurse Communication Modules',#5227,$,$); -#5229=IFCCLASSIFICATIONREFERENCE($,'23-25 35 13 11 13','Nurse Intercoms',#5227,$,$); -#5230=IFCCLASSIFICATIONREFERENCE($,'23-25 35 13 11 15','Nurse Room Control Equipment',#5227,$,$); -#5231=IFCCLASSIFICATIONREFERENCE($,'23-25 35 13 11 17','Nurse Room Control Exit Monitors',#5227,$,$); -#5232=IFCCLASSIFICATIONREFERENCE($,'23-25 35 15','Nursing Prefabricated Structures',#5223,$,$); -#5233=IFCCLASSIFICATIONREFERENCE($,'23-25 35 15 11','Nurse Stations',#5232,$,$); -#5234=IFCCLASSIFICATIONREFERENCE($,'23-25 37 00','Obstetrics and Gynecology Products',#4633,$,$); -#5235=IFCCLASSIFICATIONREFERENCE($,'23-25 37 11','Obstetrics and Gynecology Furnishings',#5234,$,$); -#5236=IFCCLASSIFICATIONREFERENCE($,'23-25 37 11 11','Obstetrics and Gynecology Beds',#5235,$,$); -#5237=IFCCLASSIFICATIONREFERENCE($,'23-25 37 11 11 11','Birthing Beds',#5236,$,$); -#5238=IFCCLASSIFICATIONREFERENCE($,'23-25 37 11 11 13','Electric Birthing Beds',#5236,$,$); -#5239=IFCCLASSIFICATIONREFERENCE($,'23-25 37 11 13','Obstetrics and Gynecology Tables',#5235,$,$); -#5240=IFCCLASSIFICATIONREFERENCE($,'23-25 37 11 13 11','Beast Biopsy Tables',#5239,$,$); -#5241=IFCCLASSIFICATIONREFERENCE($,'23-25 37 11 13 13','Gynecological Exam Tables',#5239,$,$); -#5242=IFCCLASSIFICATIONREFERENCE($,'23-25 37 11 13 15','Obstetrical Examination Tables',#5239,$,$); -#5243=IFCCLASSIFICATIONREFERENCE($,'23-25 37 13','Obstetrics and Gynecology Equipment',#5234,$,$); -#5244=IFCCLASSIFICATIONREFERENCE($,'23-25 37 13 11','Obstetrics and Gynecology Carts',#5243,$,$); -#5245=IFCCLASSIFICATIONREFERENCE($,'23-25 37 13 11 11','Fetal Monitoring Carts',#5244,$,$); -#5246=IFCCLASSIFICATIONREFERENCE($,'23-25 37 13 13','Breast Biopsy Products',#5243,$,$); -#5247=IFCCLASSIFICATIONREFERENCE($,'23-25 37 13 13 11','Minimally Invasive Breast Biopsy Premium Loading Units',#5246,$,$); -#5248=IFCCLASSIFICATIONREFERENCE($,'23-25 37 13 13 13','Minimally Invasive Breast Biopsy Vacuum Units',#5246,$,$); -#5249=IFCCLASSIFICATIONREFERENCE($,'23-25 37 15','Obstetrics and Gynecology Prefabricated Structures',#5234,$,$); -#5250=IFCCLASSIFICATIONREFERENCE($,'23-25 39 00','Ophthalmology Products',#4633,$,$); -#5251=IFCCLASSIFICATIONREFERENCE($,'23-25 39 11','Ophthalmology Furnishings',#5250,$,$); -#5252=IFCCLASSIFICATIONREFERENCE($,'23-25 39 11 11','Ophthalmology Tables',#5251,$,$); -#5253=IFCCLASSIFICATIONREFERENCE($,'23-25 39 11 11 11','Ophthalmologic Instrument Tables',#5252,$,$); -#5254=IFCCLASSIFICATIONREFERENCE($,'23-25 39 11 13','Ophthalmology Cabinets',#5251,$,$); -#5255=IFCCLASSIFICATIONREFERENCE($,'23-25 39 11 13 11','Lens Measuring Instrument Cabinets',#5254,$,$); -#5256=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13','Ophthalmology Equipment',#5250,$,$); -#5257=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11','Ophthalmic Diagnostic Exam Products',#5256,$,$); -#5258=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 11','Autorefractors',#5257,$,$); -#5259=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 13','Binocular Vision Test Sets',#5257,$,$); -#5260=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 15','Chart Projectors',#5257,$,$); -#5261=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 17','Color Perception Testing Lanterns',#5257,$,$); -#5262=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 19','Combination Refractor Keratometers',#5257,$,$); -#5263=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 21','Contact Lens Gonioscope',#5257,$,$); -#5264=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 23','Corneal Topographers',#5257,$,$); -#5265=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 25','Corneal Topography Units',#5257,$,$); -#5266=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 27','Depth Perception Units',#5257,$,$); -#5267=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 29','Electronystagmographs',#5257,$,$); -#5268=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 31','Electroretinogram Systems',#5257,$,$); -#5269=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 33','Exophthalmometers',#5257,$,$); -#5270=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 35','Eye Occluders',#5257,$,$); -#5271=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 37','Keratometer Ophthalmometers',#5257,$,$); -#5272=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 39','Keratoscopes',#5257,$,$); -#5273=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 41','Ophthalmic Colorimeters',#5257,$,$); -#5274=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 43','Ophthalmic Distometers',#5257,$,$); -#5275=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 45','Ophthalmic Drums',#5257,$,$); -#5276=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 47','Ophthalmic Euthyscopes',#5257,$,$); -#5277=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 49','Ophthalmic Eye Test Lenses',#5257,$,$); -#5278=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 51','Ophthalmic Instrument Pads',#5257,$,$); -#5279=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 53','Ophthalmic Instrument Tables',#5257,$,$); -#5280=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 55','Ophthalmic Lens Holders',#5257,$,$); -#5281=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 57','Ophthalmic Lensometers',#5257,$,$); -#5282=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 57 11','Ophthalmic Soft Contract Lensometers',#5281,$,$); -#5283=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 59','Ophthalmic Perimeters',#5257,$,$); -#5284=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 61','Ophthalmic Photometers',#5257,$,$); -#5285=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 63','Ophthalmic Prisms',#5257,$,$); -#5286=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 65','Ophthalmic Retinoscope Accessories',#5257,$,$); -#5287=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 67','Ophthalmic Retinoscopes',#5257,$,$); -#5288=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 69','Ophthalmic Slit Lamps',#5257,$,$); -#5289=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 71','Ophthalmic Spectrophotometers',#5257,$,$); -#5290=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 73','Ophthalmic Speculas',#5257,$,$); -#5291=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 75','Ophthalmic Tonometers',#5257,$,$); -#5292=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 75 11','Ophthalmic Applanation Tonometers',#5291,$,$); -#5293=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 75 13','Ophthalmic Noncontact Tonometers',#5291,$,$); -#5294=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 77','Ophthalmic Transilluminators',#5257,$,$); -#5295=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 79','Ophthalmic Visual Field Plotters',#5257,$,$); -#5296=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 81','Ophthalmic Visual Function Analyzers',#5257,$,$); -#5297=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 83','Ophthalmic Visuometers',#5257,$,$); -#5298=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 85','Ophthalmodynamometers',#5257,$,$); -#5299=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 87','Ophthalmometers',#5257,$,$); -#5300=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 89','Opthalmometer Base Plates',#5257,$,$); -#5301=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 91','Pachymeters',#5257,$,$); -#5302=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 91 11','Ultrasound Pachymeters',#5301,$,$); -#5303=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 91 13','Corneal Ultrasound Pachymeters',#5301,$,$); -#5304=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 92','Phoropter Units',#5257,$,$); -#5305=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 93','Pseudoisochromatic Plate Sets',#5257,$,$); -#5306=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 94','Tachistoscopes',#5257,$,$); -#5307=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 95','Tangent Screens',#5257,$,$); -#5308=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 96','Viewing Stands For Vision Acuity Testing',#5257,$,$); -#5309=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 97','Vision Testing Stereoscopes',#5257,$,$); -#5310=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 13','Ophthalmic Equipment',#5256,$,$); -#5311=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 13 11','Lens Edging Machines',#5310,$,$); -#5312=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 13 11 11','Lens Edging Automatic Beveling Machines',#5311,$,$); -#5313=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 13 11 13','Lens Edging Automatic Machines',#5311,$,$); -#5314=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 13 13','Ophthalmic Lasers',#5310,$,$); -#5315=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 13 13 11','Dual Fiber Photocoagulation Ophthalmic Lasers',#5314,$,$); -#5316=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 13 13 13','Ophthalmic Laser With Ophthalmoscopes',#5314,$,$); -#5317=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 13 13 15','Ophthalmic Laser With Slit Lamps',#5314,$,$); -#5318=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 13 13 17','Semiconductor Diode Ophthalmic Lasers',#5314,$,$); -#5319=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 13 15','Phacofragmentation (Cusa) Units',#5310,$,$); -#5320=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 15','Obstetrical And Gynecological Kits',#5256,$,$); -#5321=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 15 11','Amniocentesis Kits',#5320,$,$); -#5322=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 15 13','Obstetrical Extraction Units',#5320,$,$); -#5323=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 15 15','Gynecology Drainage Kits',#5320,$,$); -#5324=IFCCLASSIFICATIONREFERENCE($,'23-25 39 15','Ophthalmology Prefabricated Structures',#5250,$,$); -#5325=IFCCLASSIFICATIONREFERENCE($,'23-25 41 00','Orthopedics Products',#4633,$,$); -#5326=IFCCLASSIFICATIONREFERENCE($,'23-25 41 11','Orthopedics Furnishings',#5325,$,$); -#5327=IFCCLASSIFICATIONREFERENCE($,'23-25 41 11 11','Orthopedics Tables',#5326,$,$); -#5328=IFCCLASSIFICATIONREFERENCE($,'23-25 41 11 11 11','Medical Casting Tables',#5327,$,$); -#5329=IFCCLASSIFICATIONREFERENCE($,'23-25 41 11 11 13','Orthopedic Operating Tables',#5327,$,$); -#5330=IFCCLASSIFICATIONREFERENCE($,'23-25 41 11 11 15','Orthopedic Fracture Operating Tables',#5327,$,$); -#5331=IFCCLASSIFICATIONREFERENCE($,'23-25 41 11 13','Orthopedics Sinks',#5326,$,$); -#5332=IFCCLASSIFICATIONREFERENCE($,'23-25 41 11 13 11','Plaster Sinks',#5331,$,$); -#5333=IFCCLASSIFICATIONREFERENCE($,'23-25 41 13','Orthopedics Equipment',#5325,$,$); -#5334=IFCCLASSIFICATIONREFERENCE($,'23-25 41 13 11','Orthopedics Carts',#5333,$,$); -#5335=IFCCLASSIFICATIONREFERENCE($,'23-25 41 13 11 11','Plaster Carts',#5334,$,$); -#5336=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15','Orthopedic And Prosthetic And Sports Medicine Products',#5325,$,$); -#5337=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 11','Casting Equipment And Products',#5336,$,$); -#5338=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 11 11','Broken Arm Casting Machines',#5337,$,$); -#5339=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 11 13','Cast Carts',#5337,$,$); -#5340=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 11 15','Cast Cutters',#5337,$,$); -#5341=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 11 17','Cast Impression Trays',#5337,$,$); -#5342=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 11 19','Cast Saws',#5337,$,$); -#5343=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 11 21','Cast Stands',#5337,$,$); -#5344=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 11 23','Cast Vacuum Units',#5337,$,$); -#5345=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 11 25','Casting Induction Machines',#5337,$,$); -#5346=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 11 27','Casting Machine Guards',#5337,$,$); -#5347=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 11 29','Chrome Cobalt Casting Machines',#5337,$,$); -#5348=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 13','Orthopedic Traction Products',#5336,$,$); -#5349=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 13 11','Mobile Traction Carts',#5348,$,$); -#5350=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 13 13','Orthopedic Traction Weights',#5348,$,$); -#5351=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 13 15','Orthopedic Upper Limb Appliances',#5348,$,$); -#5352=IFCCLASSIFICATIONREFERENCE($,'23-25 41 17','Orthopedics Prefabricated Structures',#5325,$,$); -#5353=IFCCLASSIFICATIONREFERENCE($,'23-25 43 00','Otolaryngology Products',#4633,$,$); -#5354=IFCCLASSIFICATIONREFERENCE($,'23-25 43 11','Otolaryngology Furnishings',#5353,$,$); -#5355=IFCCLASSIFICATIONREFERENCE($,'23-25 43 13','Otolaryngology Equipment',#5353,$,$); -#5356=IFCCLASSIFICATIONREFERENCE($,'23-25 43 13 11','Nasal Equipment',#5355,$,$); -#5357=IFCCLASSIFICATIONREFERENCE($,'23-25 43 13 11 11','Nasal Bleeding Control Devices',#5356,$,$); -#5358=IFCCLASSIFICATIONREFERENCE($,'23-25 43 13 11 13','Nasal Flowmeters',#5356,$,$); -#5359=IFCCLASSIFICATIONREFERENCE($,'23-25 43 13 11 15','Nasal Irrigation Devices',#5356,$,$); -#5360=IFCCLASSIFICATIONREFERENCE($,'23-25 43 13 11 17','Olfactometers',#5356,$,$); -#5361=IFCCLASSIFICATIONREFERENCE($,'23-25 43 13 11 19','Rhinoanemometers',#5356,$,$); -#5362=IFCCLASSIFICATIONREFERENCE($,'23-25 43 13 13','Taste Equipment',#5355,$,$); -#5363=IFCCLASSIFICATIONREFERENCE($,'23-25 43 13 13 11','Gustometers',#5362,$,$); -#5364=IFCCLASSIFICATIONREFERENCE($,'23-25 43 13 15','Ear Equipment',#5355,$,$); -#5365=IFCCLASSIFICATIONREFERENCE($,'23-25 43 13 15 11','Earmold Equipment',#5364,$,$); -#5366=IFCCLASSIFICATIONREFERENCE($,'23-25 43 15','Otolaryngology Prefabricated Structures',#5353,$,$); -#5367=IFCCLASSIFICATIONREFERENCE($,'23-25 45 00','Patient Care Products',#4633,$,$); -#5368=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11','Patient Care Furnishings',#5367,$,$); -#5369=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 11','Patient Beds',#5368,$,$); -#5370=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 11 11','Electric Patient Beds',#5369,$,$); -#5371=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 11 13','Electric Special Care Patient Beds',#5369,$,$); -#5372=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 11 15','Hospital Bedside Rails',#5369,$,$); -#5373=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 11 17','Hospital Head Boards',#5369,$,$); -#5374=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 13','Medical Mattresses',#5368,$,$); -#5375=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 13 11','Hospital Bed Mattresses',#5374,$,$); -#5376=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 13 13','Medical Pressure Reduction Mattresses',#5374,$,$); -#5377=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 15','Patient Baths',#5368,$,$); -#5378=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 17','Patient Showers',#5368,$,$); -#5379=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 17 11','Free Standing Patient Showers',#5378,$,$); -#5380=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 17 13','Patient\X2\2019\X0\s Combination Toilets',#5378,$,$); -#5381=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 19','Patient Seating',#5368,$,$); -#5382=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 19 11','Hospital Recliners',#5381,$,$); -#5383=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 19 13','Patient Chairs',#5381,$,$); -#5384=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 21','Physically Challenged Transport Equipment',#5368,$,$); -#5385=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 21 11','Physically Challenged Multifunctional Mobility Devices',#5384,$,$); -#5386=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 21 13','Physically Challenged Positioning Devices',#5384,$,$); -#5387=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 21 15','Physically Challenged Standing Aids',#5384,$,$); -#5388=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 21 17','Physically Challenged Whole Body Sliding Devices',#5384,$,$); -#5389=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 21 19','Physically Challenged Whole Body Turning Devices',#5384,$,$); -#5390=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 21 21','Rollators',#5384,$,$); -#5391=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 21 23','Walkers',#5384,$,$); -#5392=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 23','Physically Challenged Baths and Showers',#5368,$,$); -#5393=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 23 11','Physically Challenged Bath Chairs',#5392,$,$); -#5394=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 23 13','Physically Challenged Bath Lifts',#5392,$,$); -#5395=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 23 15','Physically Challenged Bath Safety Rails',#5392,$,$); -#5396=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 23 17','Physically Challenged Bathboards',#5392,$,$); -#5397=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 23 19','Physically Challenged Shower Seats',#5392,$,$); -#5398=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 23 21','Physically Challenged Showers',#5392,$,$); -#5399=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 23 23','Physically Challenged Sitz Baths',#5392,$,$); -#5400=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 25','Physically Challenged Baths and Showers',#5368,$,$); -#5401=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 25 11','Physically Challenged Toilet Arm Supports',#5400,$,$); -#5402=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 25 13','Physically Challenged Toilet Frames',#5400,$,$); -#5403=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 25 15','Physically Challenged Toilet Grab Bars',#5400,$,$); -#5404=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 25 17','Physically Challenged Toilet Seat Lifters',#5400,$,$); -#5405=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 25 19','Physically Challenged Toilet Seats',#5400,$,$); -#5406=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 25 21','Physically Challenged Toilets',#5400,$,$); -#5407=IFCCLASSIFICATIONREFERENCE($,'23-25 45 13','Patient Care Equipment',#5367,$,$); -#5408=IFCCLASSIFICATIONREFERENCE($,'23-25 45 15','Patient Care Prefabricated Structures',#5367,$,$); -#5409=IFCCLASSIFICATIONREFERENCE($,'23-25 47 00','Patient Clinical Diagnostic Products',#4633,$,$); -#5410=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11','Patient Clinical Diagnostic Furnishings',#5409,$,$); -#5411=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 11','Privacy Screens',#5410,$,$); -#5412=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 11 11','Patient Cubicle Curtain Tracks',#5411,$,$); -#5413=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 11 13','Patient Cubicle Curtains',#5411,$,$); -#5414=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 11 15','Patient Cubicle Screens',#5411,$,$); -#5415=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 13','Patient Clinical Diagnostic Tables',#5410,$,$); -#5416=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 13 11','Examination Treatment Tables',#5415,$,$); -#5417=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 13 13','Medical Procedure Tables',#5415,$,$); -#5418=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 13 15','Minor Surgical Tables',#5415,$,$); -#5419=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 13 17','Treatment Tables',#5415,$,$); -#5420=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 15','Patient Clinical Diagnostic Sinks',#5410,$,$); -#5421=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 15 11','Clinic Sinks',#5420,$,$); -#5422=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 15 13','Clinic Scrub Sinks',#5420,$,$); -#5423=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 17','Patient Clinical Diagnostic Storage Products',#5410,$,$); -#5424=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 17 11','Patient Records Shelving Units',#5423,$,$); -#5425=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 19','Patient Clinical Diagnostic Seating',#5410,$,$); -#5426=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 19 11','Clinical Examination Chairs',#5425,$,$); -#5427=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 19 13','Physician Stools',#5425,$,$); -#5428=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 21','Patient Clinical Diagnostic Cabinets',#5410,$,$); -#5429=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 21 11','Exam Room Cabinets',#5428,$,$); -#5430=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 21 13','Pass Through Specimen Cabinets',#5428,$,$); -#5431=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 21 15','Treatment Cabinets',#5428,$,$); -#5432=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 23','Patient Clinical Diagnostic Monitor Arms',#5410,$,$); -#5433=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 23 11','Medical Facility Monitor Ceiling Arms',#5432,$,$); -#5434=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 23 13','Medical Facility Monitor Wall Arms',#5432,$,$); -#5435=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13','Patient Clinical Diagnostic Equipment',#5409,$,$); -#5436=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 11','Blood Pressure Units And Related Products',#5435,$,$); -#5437=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 11 11','Aneroid Blood Pressure Units',#5436,$,$); -#5438=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 11 13','Aneroid Sphygmomanometers',#5436,$,$); -#5439=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 11 15','Blood Pressure Recording Units',#5436,$,$); -#5440=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 11 17','Electronic Blood Pressure Units',#5436,$,$); -#5441=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 11 19','Mercury Blood Pressure Units',#5436,$,$); -#5442=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 11 21','Sphygmomanometers',#5436,$,$); -#5443=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 13','Electrocardiography EKG Units And Related Products',#5435,$,$); -#5444=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 13 11','Electrocardiography Units',#5443,$,$); -#5445=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 13 11 11','Multiple Channel Electrocardiograph Units',#5444,$,$); -#5446=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 13 11 13','Single Channel Electrocardiograph Units',#5444,$,$); -#5447=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 13 13','Electrocardiography Cable Lead Testers',#5443,$,$); -#5448=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 13 15','Electrocardiography Graphic Recorders',#5443,$,$); -#5449=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 13 17','Electrocardiography Monitors',#5443,$,$); -#5450=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 13 19','Electrocardiography Unit Analyzers',#5443,$,$); -#5451=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 13 21','Long Term Continuous Electrocardiography Monitoring Units',#5443,$,$); -#5452=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 13 23','Electrocardiography Transmitters',#5443,$,$); -#5453=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 15','Pulse Dosimeters Products',#5435,$,$); -#5454=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 15 11','Co Oximeters',#5453,$,$); -#5455=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 15 13','Pulse Oximeter Cables',#5453,$,$); -#5456=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 15 15','Pulse Oximeter Probes',#5453,$,$); -#5457=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 15 17','Pulse Oximeter Sensors',#5453,$,$); -#5458=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 15 19','Pulse Oximeter Units',#5453,$,$); -#5459=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17','Medical Exam Diagnostic Products',#5435,$,$); -#5460=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 11','Angioscopes',#5459,$,$); -#5461=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 13','Anoscopes',#5459,$,$); -#5462=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 15','Binocular Ophthalmoscopes',#5459,$,$); -#5463=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 15 11','Direct Binocular Ophthalmoscopes',#5462,$,$); -#5464=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 15 13','Indirect Binocular Ophthalmoscopes',#5462,$,$); -#5465=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 17','Body Composition Analyzer',#5459,$,$); -#5466=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 19','Bronchoscopes',#5459,$,$); -#5467=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 21','Colposcopes',#5459,$,$); -#5468=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 23','Dermatoscopes',#5459,$,$); -#5469=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 25','Electroencephalograph EEG',#5459,$,$); -#5470=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 27','Electromyographs',#5459,$,$); -#5471=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 29','Electronic Stethoscopes',#5459,$,$); -#5472=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 31','Fiberoptic Bronchoscopes',#5459,$,$); -#5473=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 31 11','Adult Fiberoptic Bronchoscopes',#5472,$,$); -#5474=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 31 13','Adult Large Channel Fiberoptic Bronchoscopes',#5472,$,$); -#5475=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 31 15','Adult Slim Casing Fiberoptic Bronchoscopes',#5472,$,$); -#5476=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 31 17','Examination Fiberoptic Bronchoscopes',#5472,$,$); -#5477=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 31 19','Pediatric Fiberoptic Bronchoscopes',#5472,$,$); -#5478=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 31 21','Therapeutic Fiberoptic Bronchoscopes',#5472,$,$); -#5479=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 33','Goniometers',#5459,$,$); -#5480=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 35','Hand Held Vascular Dopplers',#5459,$,$); -#5481=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 37','Mechanical Stethoscopes',#5459,$,$); -#5482=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 39','Nasopharyngoscopes',#5459,$,$); -#5483=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 41','Neurological Discriminators',#5459,$,$); -#5484=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 43','Neurological Sensors',#5459,$,$); -#5485=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 45','Ophthalmoscopes',#5459,$,$); -#5486=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 47','Otoscopes',#5459,$,$); -#5487=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 49','Patient Thermoregulators',#5459,$,$); -#5488=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 51','Proctoscopes',#5459,$,$); -#5489=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 53','Stethoscopic Phonocardiographs',#5459,$,$); -#5490=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 55','Therapeutic Bronchoscopes',#5459,$,$); -#5491=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 57','Vaginoscopes',#5459,$,$); -#5492=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 19','Patient Weight Scales',#5435,$,$); -#5493=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 19 11','Diaper Weight Scales',#5492,$,$); -#5494=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 19 13','Infant Scales',#5492,$,$); -#5495=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 19 15','Patient Bed Scales',#5492,$,$); -#5496=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 19 17','Patient Chair Scales',#5492,$,$); -#5497=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 19 19','Patient Floor Scales',#5492,$,$); -#5498=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 19 21','Patient Sling Scales',#5492,$,$); -#5499=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 19 23','Patient Table Scales',#5492,$,$); -#5500=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 19 25','Wheelchair Platform Scales',#5492,$,$); -#5501=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21','Patient Clinical Diagnostic Analyzers',#5435,$,$); -#5502=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 11','Amino Acid Analyzers',#5501,$,$); -#5503=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 13','Bilirubinometers',#5501,$,$); -#5504=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 15','Blood Bank Analyzers',#5501,$,$); -#5505=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 17','Blood Gas Analyzers',#5501,$,$); -#5506=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 19','Blood Chemistry Analyzers',#5501,$,$); -#5507=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 21','Chemistry Analyzers',#5501,$,$); -#5508=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 23','Coagulation Analyzers',#5501,$,$); -#5509=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 23 11','Automatic Coagulation Analyzers',#5508,$,$); -#5510=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 23 13','Fibrometers',#5508,$,$); -#5511=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 25','Deoxyribonucleic Sequence Analyzers',#5501,$,$); -#5512=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 27','Toxicology Analyzers',#5501,$,$); -#5513=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 29','Hematology Analyzers',#5501,$,$); -#5514=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 29 11','Differential Hematology Analyzers',#5513,$,$); -#5515=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 31','Histology Analyzers',#5501,$,$); -#5516=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 33','Breath Hydrogen Analyzers',#5501,$,$); -#5517=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 35','Immunology Analyzers',#5501,$,$); -#5518=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 37','Microbiology Analyzers',#5501,$,$); -#5519=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 39','Protein Analyzers',#5501,$,$); -#5520=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 41','Radioisotopic Analyzers',#5501,$,$); -#5521=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 43','Urinalysis Analyzers',#5501,$,$); -#5522=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 43 11','Advanced Urinalysis Analyzers',#5521,$,$); -#5523=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 43 13','Basic Urinalysis Analyzers',#5521,$,$); -#5524=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 45','Glucose Analyzers',#5501,$,$); -#5525=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 47','Drug Screening Chemistry Analyzers',#5501,$,$); -#5526=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 49','High Capacity Strat Chemistry Analyzers',#5501,$,$); -#5527=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 51','Multichannel Chemistry Analyzer',#5501,$,$); -#5528=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 53','Stat Chemistry Analyzers',#5501,$,$); -#5529=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 55','Enzyme Immuni Assay Analysis Units',#5501,$,$); -#5530=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 55 11','Advanced Enzyme Immuni Assay Analysis Units',#5529,$,$); -#5531=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 55 13','Basic Enzyme Immuni Assay Analysis Units',#5529,$,$); -#5532=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 55 15','Plate Washer Enzyme Immuni Assay Analysis Units',#5529,$,$); -#5533=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 55 17','Hemoglobinometers',#5529,$,$); -#5534=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 23','Patient Clinical Testing Products',#5435,$,$); -#5535=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 23 11','Cholesterol Meters',#5534,$,$); -#5536=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 23 13','Cholesterol Monitors',#5534,$,$); -#5537=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 23 15','Glucose Meters',#5534,$,$); -#5538=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 23 17','Glucose Monitors',#5534,$,$); -#5539=IFCCLASSIFICATIONREFERENCE($,'23-25 47 15','Patient Clinical Diagnostic Prefabricated Structures',#5409,$,$); -#5540=IFCCLASSIFICATIONREFERENCE($,'23-25 47 15 11','Exam Work Centers',#5539,$,$); -#5541=IFCCLASSIFICATIONREFERENCE($,'23-25 47 15 13','Gross Pathology Stations',#5539,$,$); -#5542=IFCCLASSIFICATIONREFERENCE($,'23-25 47 15 15','Hospital equipment power columns',#5539,$,$); -#5543=IFCCLASSIFICATIONREFERENCE($,'23-25 47 15 17','Medical Preparation Work Centers',#5539,$,$); -#5544=IFCCLASSIFICATIONREFERENCE($,'23-25 49 00','Patient Transportation and Lifting Equipment',#4633,$,$); -#5545=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11','Patient transport products',#5544,$,$); -#5546=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 11','Patient Transport Trolleys',#5545,$,$); -#5547=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 13','Patient Gurneys',#5545,$,$); -#5548=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 15','Geriatric Chairs',#5545,$,$); -#5549=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 17','Patient Transport Incubators',#5545,$,$); -#5550=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 19','Patient Scooters',#5545,$,$); -#5551=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 21','Patient Stretchers',#5545,$,$); -#5552=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 21 11','Cadaver Transport Stretchers',#5551,$,$); -#5553=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 21 13','Labor Recover Stretchers',#5551,$,$); -#5554=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 21 15','MRI Compatible Stretchers',#5551,$,$); -#5555=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 21 17','Surgical Recovery Stretchers',#5551,$,$); -#5556=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 23','Patient Mobile Stretchers',#5545,$,$); -#5557=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 23 11','Tapered Head Mobile Stretchers',#5556,$,$); -#5558=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 23 13','9 Position Mobile Stretchers',#5556,$,$); -#5559=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 25','Wheelchairs',#5545,$,$); -#5560=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 25 11','Electric Wheelchairs',#5559,$,$); -#5561=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 25 13','Manual Wheelchairs',#5559,$,$); -#5562=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 27','Patient Shifting Boards',#5545,$,$); -#5563=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 29','Patient Transfer Mats',#5545,$,$); -#5564=IFCCLASSIFICATIONREFERENCE($,'23-25 49 13','Patient lifts',#5544,$,$); -#5565=IFCCLASSIFICATIONREFERENCE($,'23-25 49 13 11','Patient Scissor Lifts',#5564,$,$); -#5566=IFCCLASSIFICATIONREFERENCE($,'23-25 49 13 13','Clinical Hydraulic Lifts',#5564,$,$); -#5567=IFCCLASSIFICATIONREFERENCE($,'23-25 49 13 15','Patient Suspended Seats',#5564,$,$); -#5568=IFCCLASSIFICATIONREFERENCE($,'23-25 49 13 17','Patient Suspended Slings',#5564,$,$); -#5569=IFCCLASSIFICATIONREFERENCE($,'23-25 49 13 19','Patient Ceiling Hoists',#5564,$,$); -#5570=IFCCLASSIFICATIONREFERENCE($,'23-25 49 13 21','Clinical Infant Slings',#5564,$,$); -#5571=IFCCLASSIFICATIONREFERENCE($,'23-25 49 13 21 11','Patient Hoists',#5570,$,$); -#5572=IFCCLASSIFICATIONREFERENCE($,'23-25 51 00','Pediatrics Products',#4633,$,$); -#5573=IFCCLASSIFICATIONREFERENCE($,'23-25 51 11','Pediatrics Furnishings',#5572,$,$); -#5574=IFCCLASSIFICATIONREFERENCE($,'23-25 51 11 11','Pediatric Beds',#5573,$,$); -#5575=IFCCLASSIFICATIONREFERENCE($,'23-25 51 11 11 11','Pediatric Bassinets',#5574,$,$); -#5576=IFCCLASSIFICATIONREFERENCE($,'23-25 51 11 11 13','Pediatric Beds',#5574,$,$); -#5577=IFCCLASSIFICATIONREFERENCE($,'23-25 51 11 11 15','Pediatric Cribs',#5574,$,$); -#5578=IFCCLASSIFICATIONREFERENCE($,'23-25 51 11 11 17','Pediatric Examination Tables',#5574,$,$); -#5579=IFCCLASSIFICATIONREFERENCE($,'23-25 51 11 11 19','Pediatric Incubators',#5574,$,$); -#5580=IFCCLASSIFICATIONREFERENCE($,'23-25 51 11 11 21','Pediatric Infant Positioning Cradles',#5574,$,$); -#5581=IFCCLASSIFICATIONREFERENCE($,'23-25 51 11 11 23','Pediatric Infant Warmers',#5574,$,$); -#5582=IFCCLASSIFICATIONREFERENCE($,'23-25 51 13','Pediatrics Equipment',#5572,$,$); -#5583=IFCCLASSIFICATIONREFERENCE($,'23-25 51 13 11','Pediatrics Ventilators',#5582,$,$); -#5584=IFCCLASSIFICATIONREFERENCE($,'23-25 51 13 11 11','Pediatric Intensive Care Ventilators',#5583,$,$); -#5585=IFCCLASSIFICATIONREFERENCE($,'23-25 51 13 11 13','Infant Intensive Care Ventilators',#5583,$,$); -#5586=IFCCLASSIFICATIONREFERENCE($,'23-25 51 15','Pediatrics Prefabricated Structures',#5572,$,$); -#5587=IFCCLASSIFICATIONREFERENCE($,'23-25 51 15 11','Infant Prefabricated Service Columns',#5586,$,$); -#5588=IFCCLASSIFICATIONREFERENCE($,'23-25 53 00','Pharmacology Products',#4633,$,$); -#5589=IFCCLASSIFICATIONREFERENCE($,'23-25 53 11','Pharmacology Furnishings',#5588,$,$); -#5590=IFCCLASSIFICATIONREFERENCE($,'23-25 53 11 11','Pharmacy Shelving Units',#5589,$,$); -#5591=IFCCLASSIFICATIONREFERENCE($,'23-25 53 11 13','Pharmacology Cabinets',#5589,$,$); -#5592=IFCCLASSIFICATIONREFERENCE($,'23-25 53 11 13 11','Medicine Cabinets',#5591,$,$); -#5593=IFCCLASSIFICATIONREFERENCE($,'23-25 53 11 13 13','Narcotic Cabinets',#5591,$,$); -#5594=IFCCLASSIFICATIONREFERENCE($,'23-25 53 11 13 13 11','Narcotic Cabinets With Safe',#5593,$,$); -#5595=IFCCLASSIFICATIONREFERENCE($,'23-25 53 13','Pharmacology Equipment',#5588,$,$); -#5596=IFCCLASSIFICATIONREFERENCE($,'23-25 53 13 11','Pharmacology Carts',#5595,$,$); -#5597=IFCCLASSIFICATIONREFERENCE($,'23-25 53 13 11 11','Medication Carts',#5596,$,$); -#5598=IFCCLASSIFICATIONREFERENCE($,'23-25 53 13 11 13','Unit Dose Medication Carts',#5596,$,$); -#5599=IFCCLASSIFICATIONREFERENCE($,'23-25 53 13 13','Tablet Products',#5595,$,$); -#5600=IFCCLASSIFICATIONREFERENCE($,'23-25 53 13 13 11','Tablet Crushers',#5599,$,$); -#5601=IFCCLASSIFICATIONREFERENCE($,'23-25 53 13 13 13','Tablet Crusher Dispensers',#5599,$,$); -#5602=IFCCLASSIFICATIONREFERENCE($,'23-25 53 13 13 15','Tablet Cutters',#5599,$,$); -#5603=IFCCLASSIFICATIONREFERENCE($,'23-25 53 15','Pharmacology Prefabricated Structures',#5588,$,$); -#5604=IFCCLASSIFICATIONREFERENCE($,'23-25 53 15 11','Pharmacy Stations',#5603,$,$); -#5605=IFCCLASSIFICATIONREFERENCE($,'23-25 55 00','Psychiatric and Psychology Products',#4633,$,$); -#5606=IFCCLASSIFICATIONREFERENCE($,'23-25 55 11','Psychiatric and Psychology Furnishings',#5605,$,$); -#5607=IFCCLASSIFICATIONREFERENCE($,'23-25 55 11 11','Psychiatric Beds',#5606,$,$); -#5608=IFCCLASSIFICATIONREFERENCE($,'23-25 55 11 11 11','Psychiatric Patient Showers',#5607,$,$); -#5609=IFCCLASSIFICATIONREFERENCE($,'23-25 55 11 11 13','Psychiatric Platform Bed Without Visible Legs',#5607,$,$); -#5610=IFCCLASSIFICATIONREFERENCE($,'23-25 55 11 11 15','Psychiatric Platform Beds',#5607,$,$); -#5611=IFCCLASSIFICATIONREFERENCE($,'23-25 55 11 11 17','Psychiatric Platform Beds',#5607,$,$); -#5612=IFCCLASSIFICATIONREFERENCE($,'23-25 55 13','Psychiatric and Psychology Equipment',#5605,$,$); -#5613=IFCCLASSIFICATIONREFERENCE($,'23-25 55 15','Psychiatric and Psychology Prefabricated Structures',#5605,$,$); -#5614=IFCCLASSIFICATIONREFERENCE($,'23-25 57 00','Sterilization Medical Products',#4633,$,$); -#5615=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11','Sterilizer Equipment',#5614,$,$); -#5616=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 11','Chemical Sterilizers',#5615,$,$); -#5617=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 13','Dry Heat Sterilizers',#5615,$,$); -#5618=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 15','Filter Sterilizers',#5615,$,$); -#5619=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 17','Gas Sterilizers',#5615,$,$); -#5620=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 19','Glass Bead Sterilizers',#5615,$,$); -#5621=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 21','Hot Air Sterilizers',#5615,$,$); -#5622=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 23','Needle Sterilizers',#5615,$,$); -#5623=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 25','Powered Instrument Cleaning Devices',#5615,$,$); -#5624=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 27','Radiation Sterilizers',#5615,$,$); -#5625=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 29','Sanitizer Heaters',#5615,$,$); -#5626=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 31','Steam Autoclaves',#5615,$,$); -#5627=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 33','Steam Sterilizers',#5615,$,$); -#5628=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 35','Sterilization Cabinets',#5615,$,$); -#5629=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 37','Sterilization Lamps',#5615,$,$); -#5630=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 39','Sterilization Water Recovery Equipment',#5615,$,$); -#5631=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 41','Double Chamber Ultrasonic Cleaners',#5615,$,$); -#5632=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 43','Single Chamber Ultrasonic Cleaners',#5615,$,$); -#5633=IFCCLASSIFICATIONREFERENCE($,'23-25 59 00','Surgical Products',#4633,$,$); -#5634=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11','Surgical Furnishings',#5633,$,$); -#5635=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 11','Surgical Beds',#5634,$,$); -#5636=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 11 11','Surgical Bedside Rails',#5635,$,$); -#5637=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 13','Surgical Sinks',#5634,$,$); -#5638=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 13 11','Surgeon Scrub Sinks',#5637,$,$); -#5639=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 13 13','Surgeon\X2\2019\X0\s Instrument Sinks',#5637,$,$); -#5640=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 15','Surgical Tables',#5634,$,$); -#5641=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 15 11','Surgical Instrument Tables',#5640,$,$); -#5642=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 15 13','Spinal Operating Tables',#5640,$,$); -#5643=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 15 15','Surgical Operating Tables',#5640,$,$); -#5644=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 15 17','Straddle Instrument Tables',#5640,$,$); -#5645=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 15 19','Medical Dressing Instrument Tables',#5640,$,$); -#5646=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 15 21','Cesarean Section Patient Procedure Tables',#5640,$,$); -#5647=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 15 23','Delivery Room Patient Procedure Tables',#5640,$,$); -#5648=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 15 25','Surgical Instrument Tables',#5640,$,$); -#5649=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 15 27','Operating Room Patient Fracture Tables',#5640,$,$); -#5650=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 15 29','Operating Room Patient Procedure Tables',#5640,$,$); -#5651=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 15 31','Surgical Equipment Stands',#5640,$,$); -#5652=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 17','Surgical Seating',#5634,$,$); -#5653=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 17 11','Surgeon Stools',#5652,$,$); -#5654=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 17 13','Rolling Surgeons Stools',#5652,$,$); -#5655=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 17 15','Surgical Step Stools',#5652,$,$); -#5656=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 19','Surgical Cabinets',#5634,$,$); -#5657=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 19 11','Surgical Instrument Cabinets',#5656,$,$); -#5658=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13','Surgical Equipment',#5633,$,$); -#5659=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 11','Surgical Carts',#5658,$,$); -#5660=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 11 11','Sterilizable Loading Carts',#5659,$,$); -#5661=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 11 13','Surgical Case Carts',#5659,$,$); -#5662=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 11 15','Surgical Dressing Carts',#5659,$,$); -#5663=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 11 17','Operating Room Case Carts',#5659,$,$); -#5664=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13','Cardiovascular Products',#5658,$,$); -#5665=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 11','Heart And Lung Machines',#5664,$,$); -#5666=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 13','Intraaortic Balloon Pumps',#5664,$,$); -#5667=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 15','Intracardiac Suction Devices',#5664,$,$); -#5668=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 17','Perfusion Blood Parameter Monitors',#5664,$,$); -#5669=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 19','Perfusion Bubble Traps',#5664,$,$); -#5670=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 21','Perfusion Cardioplegia Sets',#5664,$,$); -#5671=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 23','Perfusion Cardiotomy Reservoirs',#5664,$,$); -#5672=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 25','Perfusion Centrifugal Equipment',#5664,$,$); -#5673=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 27','Perfusion Heaters',#5664,$,$); -#5674=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 29','Perfusion Coolers',#5664,$,$); -#5675=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 31','Perfusion Dual Heater And Cooler Units',#5664,$,$); -#5676=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 33','Perfusion Haemoconcentrators',#5664,$,$); -#5677=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 35','Perfusion Oxygen Saturation Monitors',#5664,$,$); -#5678=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 37','Perfusion Oxygenators',#5664,$,$); -#5679=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 39','Perfusion Pump Heads',#5664,$,$); -#5680=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 41','Perfusion Venous Reservoirs',#5664,$,$); -#5681=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 43','Ventricular Assist Devices',#5664,$,$); -#5682=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 45','Perfusion Pumps',#5664,$,$); -#5683=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 47','Cardiovascular Reservoirs',#5664,$,$); -#5684=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 49','Surgical Coronary Artery Blowers',#5664,$,$); -#5685=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 51','Surgical Coronary Artery Misters',#5664,$,$); -#5686=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15','Surgical Equipment',#5658,$,$); -#5687=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 11','Surgical Basin Stands',#5686,$,$); -#5688=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 13','Cryosurgery Equipment',#5686,$,$); -#5689=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 15','Electrocautery Equipment',#5686,$,$); -#5690=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 17','Ophthalmic Irrigation Equipment',#5686,$,$); -#5691=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 19','Ophthalmic Surgery Phacoemulsification Equipment',#5686,$,$); -#5692=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 21','Ophthalmic Surgery Extrusion Equipment',#5686,$,$); -#5693=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 23','Surgical Irrigation Pumps',#5686,$,$); -#5694=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 25','Pulsed Lavage Units With Suction',#5686,$,$); -#5695=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 27','Pulsed Lavage Units With Out Suction',#5686,$,$); -#5696=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 29','Surgical Lasers',#5686,$,$); -#5697=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 29 11','CO2 Surgical Lasers',#5696,$,$); -#5698=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 29 13','KTP Surgical Lasers',#5696,$,$); -#5699=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 31','Surgical Lithotripters',#5686,$,$); -#5700=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 31 11','Extracorporeal Lithotripters',#5699,$,$); -#5701=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 31 13','Ultrasound Lithotripters',#5699,$,$); -#5702=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 33','Surgical Microscopes',#5686,$,$); -#5703=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 35','Surgical Magnifiers',#5686,$,$); -#5704=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 37','Surgical Pneumatic Tourniquets',#5686,$,$); -#5705=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 39','Surgical Electric Tourniquets',#5686,$,$); -#5706=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 41','Surgical Aspirators',#5686,$,$); -#5707=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 41 11','General Purpose Aspirator Pressure Units',#5706,$,$); -#5708=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 41 13','Low Pressure High Volume Suction Chest and Abdomen Aspirators',#5706,$,$); -#5709=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 41 15','Low Pressure Low Volume Suction Surgical Aspirators',#5706,$,$); -#5710=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 41 17','Mobile Uterine Aspirators',#5706,$,$); -#5711=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 43','Surgical Urological Tables',#5686,$,$); -#5712=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 45','Vitreo Retinal Fragmatome Surgery Equipment',#5686,$,$); -#5713=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 47','Microsurgery Equipment',#5686,$,$); -#5714=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 49','Operating Room Medication Dispensers',#5686,$,$); -#5715=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 51','Surgical Dermatomes',#5686,$,$); -#5716=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 53','Surgical Dermabraders',#5686,$,$); -#5717=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 55','Surgical Dermameshers',#5686,$,$); -#5718=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 57','Surgical Pneumatic Saws',#5686,$,$); -#5719=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 59','Surgical Pneumatic Drills',#5686,$,$); -#5720=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 61','Surgical Power Pin Drivers',#5686,$,$); -#5721=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 63','Surgical Power Saws',#5686,$,$); -#5722=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 65','Surgical Power Drills',#5686,$,$); -#5723=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 67','Surgical Power Pin Drivers',#5686,$,$); -#5724=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 69','Surgical Reamers',#5686,$,$); -#5725=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 71','Surgical Shavers',#5686,$,$); -#5726=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 73','Electrosurgical Units',#5686,$,$); -#5727=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 73 11','Dual Output Electrosurgical Units',#5726,$,$); -#5728=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 73 13','Endoscopy Electrosurgical Units',#5726,$,$); -#5729=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 73 15','Monopolar Electrosurgical Units',#5726,$,$); -#5730=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 73 17','Unblended Mobile Electrosurgical Units',#5726,$,$); -#5731=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 17','Surgical Lighting Fixtures',#5658,$,$); -#5732=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 17 11','Surgical Operating Room Lighting Fixtures',#5731,$,$); -#5733=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 19','Surgical Support Products',#5658,$,$); -#5734=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 19 11','Surgical Basin Sets',#5733,$,$); -#5735=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 19 13','Surgical Bone Cement Mixing Equipment',#5733,$,$); -#5736=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 19 15','Surgical Suction Canisters',#5733,$,$); -#5737=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 19 17','Surgical Glove Drying Or Powdering Equipment',#5733,$,$); -#5738=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 19 19','Surgical Fluid Decanting Devices',#5733,$,$); -#5739=IFCCLASSIFICATIONREFERENCE($,'23-25 59 15','Surgical Prefabricated Structures',#5633,$,$); -#5740=IFCCLASSIFICATIONREFERENCE($,'23-25 59 15 11','Surgical Prefabricated Service Columns',#5739,$,$); -#5741=IFCCLASSIFICATIONREFERENCE($,'23-25 61 00','Veterinary and Animal Products',#4633,$,$); -#5742=IFCCLASSIFICATIONREFERENCE($,'23-25 61 11','Veterinary and Animal Furnishings',#5741,$,$); -#5743=IFCCLASSIFICATIONREFERENCE($,'23-25 61 11 11','Veterinary Tables',#5742,$,$); -#5744=IFCCLASSIFICATIONREFERENCE($,'23-25 61 11 11 11','Veterinary Operating Tables',#5743,$,$); -#5745=IFCCLASSIFICATIONREFERENCE($,'23-25 61 11 11 13','Postmortem Animal Dissection Tables',#5743,$,$); -#5746=IFCCLASSIFICATIONREFERENCE($,'23-25 61 11 11 15','Necropsy Tables',#5743,$,$); -#5747=IFCCLASSIFICATIONREFERENCE($,'23-25 61 11 11 17','Veterinary Surgical Tables',#5743,$,$); -#5748=IFCCLASSIFICATIONREFERENCE($,'23-25 61 11 13','Veterinary Sinks',#5742,$,$); -#5749=IFCCLASSIFICATIONREFERENCE($,'23-25 61 11 13 11','Animal Cage Washing Sinks',#5748,$,$); -#5750=IFCCLASSIFICATIONREFERENCE($,'23-25 61 11 15','Veterinary Storage Chests',#5742,$,$); -#5751=IFCCLASSIFICATIONREFERENCE($,'23-25 61 13','Veterinary and Animal Equipment',#5741,$,$); -#5752=IFCCLASSIFICATIONREFERENCE($,'23-25 61 13 11','Animal Containment Products',#5751,$,$); -#5753=IFCCLASSIFICATIONREFERENCE($,'23-25 61 13 11 10','Cage Washers',#5752,$,$); -#5754=IFCCLASSIFICATIONREFERENCE($,'23-25 61 13 11 11','Small Animal Laboratory Cages',#5752,$,$); -#5755=IFCCLASSIFICATIONREFERENCE($,'23-25 61 13 11 13','Large Animal Laboratory Cages',#5752,$,$); -#5756=IFCCLASSIFICATIONREFERENCE($,'23-25 61 13 11 15','Large Animal Mobile Kennels',#5752,$,$); -#5757=IFCCLASSIFICATIONREFERENCE($,'23-25 61 13 11 15 11','Intensive Care Large Animal Mobile Kennels',#5756,$,$); -#5758=IFCCLASSIFICATIONREFERENCE($,'23-25 61 13 11 17','Small Animal Mobile Kennels',#5752,$,$); -#5759=IFCCLASSIFICATIONREFERENCE($,'23-25 61 13 11 17 11','Intensive Care Small Animal Mobile Kennels',#5758,$,$); -#5760=IFCCLASSIFICATIONREFERENCE($,'23-25 61 13 11 19','Aquaria Equipment',#5752,$,$); -#5761=IFCCLASSIFICATIONREFERENCE($,'23-25 61 13 11 21','Animal Catching Devices',#5752,$,$); -#5762=IFCCLASSIFICATIONREFERENCE($,'23-25 61 13 11 23','Fish Aeration Systems',#5752,$,$); -#5763=IFCCLASSIFICATIONREFERENCE($,'23-25 61 15','Veterinary Equipment',#5741,$,$); -#5764=IFCCLASSIFICATIONREFERENCE($,'23-25 61 15 11','Veterinary Blood Pressure Testers',#5763,$,$); -#5765=IFCCLASSIFICATIONREFERENCE($,'23-25 61 15 13','Veterinary Kymograph Testers',#5763,$,$); -#5766=IFCCLASSIFICATIONREFERENCE($,'23-25 61 15 15','Veterinary Pyrogenic Testers',#5763,$,$); -#5767=IFCCLASSIFICATIONREFERENCE($,'23-25 61 15 17','Veterinary Stereotoxic Equipment',#5763,$,$); -#5768=IFCCLASSIFICATIONREFERENCE($,'23-25 61 15 19','Veterinary Electrocardiographs ECG',#5763,$,$); -#5769=IFCCLASSIFICATIONREFERENCE($,'23-25 61 17','Veterinary and Animal Prefabricated Structures',#5741,$,$); -#5770=IFCCLASSIFICATIONREFERENCE($,'23-25 63 00','X Ray and Imagery Products',#4633,$,$); -#5771=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11','X Ray and Imagery Furnishings',#5770,$,$); -#5772=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 11','X Ray and Imagery Sinks',#5771,$,$); -#5773=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 11 11','Film Processing Sinks',#5772,$,$); -#5774=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 11 13','Lead Lined Sinks',#5772,$,$); -#5775=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 11 13 11','Lead Lined With Decay Storage Sinks',#5774,$,$); -#5776=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 13','X Ray and Imagery Protective Barriers',#5771,$,$); -#5777=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 13 11','X Ray Protective Screens',#5776,$,$); -#5778=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 13 13','Radiofrequency Proective Screens',#5776,$,$); -#5779=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 13 15','Radiological Shielding Apron Racks',#5776,$,$); -#5780=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 13 17','Portable Radioactive Materials Containers',#5776,$,$); -#5781=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 13 19','Radiological Shielding Freestanding Screens',#5776,$,$); -#5782=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 13 21','Radiological Shielding Wall',#5776,$,$); -#5783=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 13 23','Radiological Shielding Ceiling Panels',#5776,$,$); -#5784=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 13 25','Radiological Shielding Floor Installed Panels',#5776,$,$); -#5785=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 15','X Ray and Imagery Storage Units',#5771,$,$); -#5786=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 15 11','Lead Lined Storage Cabinets',#5785,$,$); -#5787=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 15 13','Photographic Slides Storage Cabinets',#5785,$,$); -#5788=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13','X Ray and Imagery Equipment',#5770,$,$); -#5789=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 11','X Ray and Imagery Carts',#5788,$,$); -#5790=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 11 11','Radium Transport Carts',#5789,$,$); -#5791=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13','Computed Tomography CT and CAT Products',#5788,$,$); -#5792=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 11','Computed Tomography CT Complete Stationary Units',#5791,$,$); -#5793=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 13','Computed Tomography CT Mobile Units',#5791,$,$); -#5794=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 15','Computed Tomography CT Van Units',#5791,$,$); -#5795=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 17','Computed Tomography CT Consoles',#5791,$,$); -#5796=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 19','Computed Tomography CT Power Conditioners',#5791,$,$); -#5797=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 21','Computed Tomography CT Tables',#5791,$,$); -#5798=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 23','Computed Tomography CT Chairs',#5791,$,$); -#5799=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 25','Computed Tomography CAT Complete Stationary Units',#5791,$,$); -#5800=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 27','Computed Tomography CAT Mobile Units',#5791,$,$); -#5801=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 29','Computed Tomography CAT Transportable Units',#5791,$,$); -#5802=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 31','Computed Tomography CAT Van Units',#5791,$,$); -#5803=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 33','Computed Tomography CAT Consoles',#5791,$,$); -#5804=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 35','Computed Tomography CAT Power Conditioners',#5791,$,$); -#5805=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 37','Computed Tomography CAT Tables',#5791,$,$); -#5806=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 39','Computed Tomography CAT Chairs',#5791,$,$); -#5807=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 41','Computerized Tomography Phantoms',#5791,$,$); -#5808=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 41 11','Body Computerized Tomography Phantoms',#5807,$,$); -#5809=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 41 13','Head Computerized Tomography Phantoms',#5807,$,$); -#5810=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 41 15','Performance Computerized Tomography Phantoms',#5807,$,$); -#5811=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 43','Computed Tomography CT Radiotherapy Simulators',#5791,$,$); -#5812=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 45','Computed Tomography CAT Radiotherapy Simulators',#5791,$,$); -#5813=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 15','Magnetic Resonance Imaging Products',#5788,$,$); -#5814=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 15 11','Medical Magnetic Resonance Imaging Complete Stationary Unit Installation',#5813,$,$); -#5815=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 15 13','Medical Magnetic Resonance Imaging Mobile Units',#5813,$,$); -#5816=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 15 15','Medical Magnetic Resonance Imaging Transportable Units',#5813,$,$); -#5817=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 15 17','Medical Magnetic Resonance Imaging Van Units',#5813,$,$); -#5818=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 15 19','Medical Magnetic Resonance Imaging Monitors',#5813,$,$); -#5819=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 15 21','Medical Magnetic Resonance Imaging Scanners',#5813,$,$); -#5820=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 15 23','Medical Magnetic Resonance Imaging Tables',#5813,$,$); -#5821=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17','Ultrasound Doppler And Echo Imaging Products',#5788,$,$); -#5822=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 11','Cardiac Ultrasound Units',#5821,$,$); -#5823=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 13','Cardiac Doppler Units',#5821,$,$); -#5824=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 15','Cardiac Echo Units',#5821,$,$); -#5825=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 17','Cardioscopes',#5821,$,$); -#5826=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 19','Fetal Ultrasound Units',#5821,$,$); -#5827=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 21','Fetal Echo Units',#5821,$,$); -#5828=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 23','Gynecological Ultrasound Units',#5821,$,$); -#5829=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 25','Gynecological Echo Units',#5821,$,$); -#5830=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 27','Mammographic Ultrasound Units',#5821,$,$); -#5831=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 29','Mammographic Echo Units',#5821,$,$); -#5832=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 31','Medical Ultrasound Bone Densitometers',#5821,$,$); -#5833=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 33','Medical Ultrasound Or Doppler Or Echo Monitors',#5821,$,$); -#5834=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 35','Medical Ultrasound Or Doppler Or Echo Printers',#5821,$,$); -#5835=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 37','Medical Ultrasound Transducers',#5821,$,$); -#5836=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 39','Medical Doppler Transducers',#5821,$,$); -#5837=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 41','Medical Echo Transducers',#5821,$,$); -#5838=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 43','Medical General Use Ultrasound Units',#5821,$,$); -#5839=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 45','Medical General Use Doppler Units',#5821,$,$); -#5840=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 47','Medical General Use Pulse Echo Units',#5821,$,$); -#5841=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 49','Medical General Use Echography Units',#5821,$,$); -#5842=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 51','Thesiometers',#5821,$,$); -#5843=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 53','Vaginal Ultrasound Or Echo Probes',#5821,$,$); -#5844=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 55','Vascular Ultrasound Units',#5821,$,$); -#5845=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 57','Medical Ultrasound Ophthalmic Scanners',#5821,$,$); -#5846=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19','X Ray Products',#5788,$,$); -#5847=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 11','Chest X Ray Equipment',#5846,$,$); -#5848=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 13','Mammography X Ray Equipment',#5846,$,$); -#5849=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 15','Medical C Arm X Ray Units',#5846,$,$); -#5850=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 17','Medical Cine Fluoroscopy Equipment',#5846,$,$); -#5851=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 19','Medical Radiology And Fluoroscopy RF Equipment',#5846,$,$); -#5852=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 21','Medical Radioisotope Scanners',#5846,$,$); -#5853=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 23','Medical X Ray Buckys',#5846,$,$); -#5854=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 25','Medical X Ray Quality Assurance Calibration Devices',#5846,$,$); -#5855=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 27','Medical X Ray Tables',#5846,$,$); -#5856=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 29','Medical X Ray Stands',#5846,$,$); -#5857=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 31','Medical X Ray Chairs',#5846,$,$); -#5858=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 33','Medical X Ray Cabinets',#5846,$,$); -#5859=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 35','Medical X Ray Tomography Units',#5846,$,$); -#5860=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 37','Medical Diagnostic Use X Ray Units',#5846,$,$); -#5861=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 39','Medical Xeroradiography Units',#5846,$,$); -#5862=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 41','X Ray Bone Densitometers',#5846,$,$); -#5863=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 43','Medical X Ray Intensifying Screens',#5846,$,$); -#5864=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 45','Medical X Ray Water Coolers',#5846,$,$); -#5865=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 47','Medical Imaging Procedure Trays',#5846,$,$); -#5866=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 49','Medical X Ray Film Hot Spot Lights',#5846,$,$); -#5867=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 51','Medical X Ray Film Large Rack Viewing Systems',#5846,$,$); -#5868=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 53','Medical X Ray Film View Boxes',#5846,$,$); -#5869=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 55','Medical X Ray Film Illuminator Windows',#5846,$,$); -#5870=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 57','Medical X Ray Film Illuminator Screens',#5846,$,$); -#5871=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 59','Medical X Ray Film Stereoscopes',#5846,$,$); -#5872=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 21','Gamma Cameras Products',#5788,$,$); -#5873=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 21 11','Medical General Use Gamma Cameras',#5872,$,$); -#5874=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 21 13','Lymphatic Mapping Navigator Equipment',#5872,$,$); -#5875=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 21 15','Lymphatic Mapping Probes',#5872,$,$); -#5876=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 21 17','Lymphatic Mapping Collimators',#5872,$,$); -#5877=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 23','Gamma Radiation Therapy Products',#5788,$,$); -#5878=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 23 11','Radiosurgical Gamma Knife Collimators',#5877,$,$); -#5879=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 23 13','Radiosurgical Gamma Knife Units',#5877,$,$); -#5880=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 23 15','Radiosurgical Gamma Scintillators',#5877,$,$); -#5881=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 25','Linear Accelerator Intensity Modulated Radiation Therapy Units',#5788,$,$); -#5882=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 25 11','Medical Linear Accelerator Intensity Modulated Radiation Therapy IMRT Two Dimensional Units',#5881,$,$); -#5883=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 25 13','Medical Linear Accelerator Intensity Modulated Radiation Therapy IMRT Three Dimensional Units',#5881,$,$); -#5884=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 25 15','Medical Linear Accelerator Intensity Modulated Radiation Therapy IMRT Collimators',#5881,$,$); -#5885=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 25 17','Dual Energy Linear Accelerator',#5881,$,$); -#5886=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 27','Medical Positron Emission Tomography Units',#5788,$,$); -#5887=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 27 11','Medical Positron Emission Tomography PET Units',#5886,$,$); -#5888=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 29','Medical Single Photon Emission Computed Tomography Units',#5788,$,$); -#5889=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 29 11','Medical Single Photon Emission Computed Tomography SPECT Units',#5888,$,$); -#5890=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 31','Radiotherapy Teletherapy Products',#5788,$,$); -#5891=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 31 11','Radiotherapy Teletherapy Cobalt 60 Equipment',#5890,$,$); -#5892=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 31 13','Radiotherapy Teletherapy Linear Accelerators',#5890,$,$); -#5893=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 31 15','Radiotherapy Teletherapy Orthovoltage X Ray Machines',#5890,$,$); -#5894=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 31 17','Radiotherapy Teletherapy Superficial X Ray Machines',#5890,$,$); -#5895=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 31 19','Radiotherapy Cutters',#5890,$,$); -#5896=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 31 19 11','Radiotherapy Beam Block Cutters',#5895,$,$); -#5897=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 31 19 13','Radiotherapy Compensator Cutters',#5895,$,$); -#5898=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 33','Radiographic Fluoroscopic Units',#5788,$,$); -#5899=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 33 11','Computerized Tomography Radiographic Fluoroscopic Units',#5898,$,$); -#5900=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 33 13','Digital Angio Biplane Radiographic Fluoroscopic Units',#5898,$,$); -#5901=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 33 15','Digital Cardiac Radiographic Fluoroscopic Units',#5898,$,$); -#5902=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 33 17','Digital Chest Radiographic Fluoroscopic Units',#5898,$,$); -#5903=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 33 19','Mammographic Radiographic Fluoroscopic Units',#5898,$,$); -#5904=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 33 21','Non Tilt Table Radiographic Units',#5898,$,$); -#5905=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 33 23','Table Radiographic Fluoroscopic Units',#5898,$,$); -#5906=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 33 23 11','Remote Table Radiographic Fluoroscopic Units',#5905,$,$); -#5907=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 33 25','Urologic Radiographic Fluoroscopic Units',#5898,$,$); -#5908=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 33 25 11','Computerized Tomography Urologic Radiographic Fluoroscopic Units',#5907,$,$); -#5909=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 35','Radiation Detection Or Monitoring Products',#5788,$,$); -#5910=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 35 11','Radiation Dosimeters',#5909,$,$); -#5911=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 35 13','Radiation Badges',#5909,$,$); -#5912=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 35 15','Radiation Detectors',#5909,$,$); -#5913=IFCCLASSIFICATIONREFERENCE($,'23-25 63 15','X Ray and Imagery Prefabricated Structures',#5770,$,$); -#5914=IFCCLASSIFICATIONREFERENCE($,'23-25 63 15 11','Radiological Shielding Chambers',#5913,$,$); -#5915=IFCCLASSIFICATIONREFERENCE($,'23-25 63 15 13','Radiological Shielding Rooms',#5913,$,$); -#5916=IFCCLASSIFICATIONREFERENCE($,'23-25 63 15 15','Radiological Shielding Safes',#5913,$,$); -#5917=IFCCLASSIFICATIONREFERENCE($,'23-25 63 17','Specialized Medical Computer Equipment',#5770,$,$); -#5918=IFCCLASSIFICATIONREFERENCE($,'23-25 63 17 11','Computer Assisted Cardiology Management System',#5917,$,$); -#5919=IFCCLASSIFICATIONREFERENCE($,'23-25 63 17 13','Nuclear Medicine Clinical Computers',#5917,$,$); -#5920=IFCCLASSIFICATIONREFERENCE($,'23-25 63 17 15','DIN PACS Computer System',#5917,$,$); -#5921=IFCCLASSIFICATIONREFERENCE($,'23-25 63 17 17','Holter Monitor Analysis Computer System',#5917,$,$); -#5922=IFCCLASSIFICATIONREFERENCE($,'23-25 63 17 19','Mean Cell Volume Computers',#5917,$,$); -#5923=IFCCLASSIFICATIONREFERENCE($,'23-25 63 17 21','Radiation Therapy Treatment Planning Computers',#5917,$,$); -#5924=IFCCLASSIFICATIONREFERENCE($,'23-25 65 00','Biological Protection and Preservation Products',#4633,$,$); -#5925=IFCCLASSIFICATIONREFERENCE($,'23-25 65 11','Biological Safety Cabinets',#5924,$,$); -#5926=IFCCLASSIFICATIONREFERENCE($,'23-25 65 11 11','Biological Safety Class I Cabinets',#5925,$,$); -#5927=IFCCLASSIFICATIONREFERENCE($,'23-25 65 11 13','Biological Safety Class II Cabinets',#5925,$,$); -#5928=IFCCLASSIFICATIONREFERENCE($,'23-25 65 11 15','Biological Safety Class III Cabinets',#5925,$,$); -#5929=IFCCLASSIFICATIONREFERENCE($,'23-25 65 11 17','Cryogenic Freezers',#5925,$,$); -#5930=IFCCLASSIFICATIONREFERENCE($,'23-25 65 11 19','Biological Freezers',#5925,$,$); -#5931=IFCCLASSIFICATIONREFERENCE($,'23-25 65 11 21','Biological Refrigerators',#5925,$,$); -#5932=IFCCLASSIFICATIONREFERENCE($,'23-25 65 13','Cabinet Bases',#5924,$,$); -#5933=IFCCLASSIFICATIONREFERENCE($,'23-25 65 13 11','Biological Safety Class I Cabinet Bases',#5932,$,$); -#5934=IFCCLASSIFICATIONREFERENCE($,'23-25 65 13 13','Biological Safety Class II Cabinet Bases',#5932,$,$); -#5935=IFCCLASSIFICATIONREFERENCE($,'23-25 65 13 15','Biological Safety Class III Cabinet Bases',#5932,$,$); -#5936=IFCCLASSIFICATIONREFERENCE($,'23-25 67 00','Hazardous Materials Products',#4633,$,$); -#5937=IFCCLASSIFICATIONREFERENCE($,'23-25 67 11','Hazardous Materials Cabinets',#5936,$,$); -#5938=IFCCLASSIFICATIONREFERENCE($,'23-25 67 11 11','Acid Storage Cabinets',#5937,$,$); -#5939=IFCCLASSIFICATIONREFERENCE($,'23-25 67 11 13','Flammable Storage Cabinets',#5937,$,$); -#5940=IFCCLASSIFICATIONREFERENCE($,'23-25 67 13','Hazardous Materials Refrigerators and Freezers',#5936,$,$); -#5941=IFCCLASSIFICATIONREFERENCE($,'23-25 67 13 11','Flammable Material Storage Refrigerators',#5940,$,$); -#5942=IFCCLASSIFICATIONREFERENCE($,'23-25 67 13 13','Flammable Material Storage Freezers',#5940,$,$); -#5943=IFCCLASSIFICATIONREFERENCE($,'23-25 67 13 15','Flammable Material Storage Refrigerator Freezers',#5940,$,$); -#5944=IFCCLASSIFICATIONREFERENCE($,'23-25 67 13 17','Explosion Proof Refrigerators',#5940,$,$); -#5945=IFCCLASSIFICATIONREFERENCE($,'23-25 67 13 19','Explosion Proof Refrigerator Freezers',#5940,$,$); -#5946=IFCCLASSIFICATIONREFERENCE($,'23-25 69 00','Laboratory and Scientific Products',#4633,$,$); -#5947=IFCCLASSIFICATIONREFERENCE($,'23-25 69 11','Laboratory Furnishings',#5946,$,$); -#5948=IFCCLASSIFICATIONREFERENCE($,'23-25 69 11 11','Laboratory Tables',#5947,$,$); -#5949=IFCCLASSIFICATIONREFERENCE($,'23-25 69 11 11 11','Microscope Tables',#5948,$,$); -#5950=IFCCLASSIFICATIONREFERENCE($,'23-25 69 11 13','Laboratory Seating',#5947,$,$); -#5951=IFCCLASSIFICATIONREFERENCE($,'23-25 69 11 15','Laboratory Fume hoods',#5947,$,$); -#5952=IFCCLASSIFICATIONREFERENCE($,'23-25 69 11 15 11','Bench Fume hoods',#5951,$,$); -#5953=IFCCLASSIFICATIONREFERENCE($,'23-25 69 11 15 11 11','Horizontal Laminar Flow Bench Fume hoods',#5952,$,$); -#5954=IFCCLASSIFICATIONREFERENCE($,'23-25 69 11 15 13','Floor Standing Fume hoods',#5951,$,$); -#5955=IFCCLASSIFICATIONREFERENCE($,'23-25 69 11 15 13 11','Horizontal Laminar Flow Free Standing Fume hoods',#5954,$,$); -#5956=IFCCLASSIFICATIONREFERENCE($,'23-25 69 11 15 13 13','Explosion Proof Floor Standing Fume hoods',#5954,$,$); -#5957=IFCCLASSIFICATIONREFERENCE($,'23-25 69 11 15 13 15','Perchloric Floor Standing Fume Hoods',#5954,$,$); -#5958=IFCCLASSIFICATIONREFERENCE($,'23-25 69 11 15 15','Histopathology Staining Fume Hoods',#5951,$,$); -#5959=IFCCLASSIFICATIONREFERENCE($,'23-25 69 11 15 17','Horizontal Laminar Flow Fume Hoods',#5951,$,$); -#5960=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13','Laboratory And Scientific Equipment',#5946,$,$); -#5961=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11','Microscopes',#5960,$,$); -#5962=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 11','Acoustic Microscopes',#5961,$,$); -#5963=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 13','Binocular Microscopes',#5961,$,$); -#5964=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 13 11','Phase Contrast Binocular Microscopes',#5963,$,$); -#5965=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 13 13','Binocular Light Compound Microscopes',#5963,$,$); -#5966=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 15','Bore scope Inspection Equipment',#5961,$,$); -#5967=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 17','Combination Electron And Light Microscopes',#5961,$,$); -#5968=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 19','Dark field Microscopes',#5961,$,$); -#5969=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 21','Digital Image Varityping Microscopes',#5961,$,$); -#5970=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 23','Dissecting Light Microscopes',#5961,$,$); -#5971=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 25','Electron Microscopes',#5961,$,$); -#5972=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 27','Fluorescence Microscopes',#5961,$,$); -#5973=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 29','Fluorescent Microscopes',#5961,$,$); -#5974=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 31','Inverted Microscopes',#5961,$,$); -#5975=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 33','Ion Microscopes',#5961,$,$); -#5976=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 35','Laser Scanning Microscopes',#5961,$,$); -#5977=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 37','Metallurgical Microscopes',#5961,$,$); -#5978=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 39','Monocular Microscopes',#5961,$,$); -#5979=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 41','Operating Microscopes',#5961,$,$); -#5980=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 43','Photographic Fluorescent Microscopes',#5961,$,$); -#5981=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 45','Photographic Microscopes',#5961,$,$); -#5982=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 47','Polarizing Microscopes',#5961,$,$); -#5983=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 49','Projection Microscopes',#5961,$,$); -#5984=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 51','Scanning Electron Microscopes',#5961,$,$); -#5985=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 53','Scanning Light Microscopes',#5961,$,$); -#5986=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 55','Scanning Probe Microscopes',#5961,$,$); -#5987=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 57','Spinning Disk Microscopes',#5961,$,$); -#5988=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 59','Stereo Microscopes',#5961,$,$); -#5989=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 61','Tissue Culture Inverted Microscopes',#5961,$,$); -#5990=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 63','Transmission Electron Microscopes',#5961,$,$); -#5991=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 65','Trinocular Microscopes',#5961,$,$); -#5992=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 67','Wide Field Microscopes',#5961,$,$); -#5993=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 13','Optical Equipment',#5960,$,$); -#5994=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 13 11','Telescopes',#5993,$,$); -#5995=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 13 13','Binoculars',#5993,$,$); -#5996=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 13 15','Videoscopes',#5993,$,$); -#5997=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 13 17','Fiberscopes',#5993,$,$); -#5998=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15','Laboratory Disruption Equipment',#5960,$,$); -#5999=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15 11','French Pressure Cells',#5998,$,$); -#6000=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15 13','Homogenizers',#5998,$,$); -#6001=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15 15','Laboratory Blenders',#5998,$,$); -#6002=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15 17','Laboratory Crushers',#5998,$,$); -#6003=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15 19','Laboratory Disintegrators',#5998,$,$); -#6004=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15 21','Laboratory Emulsifiers',#5998,$,$); -#6005=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15 23','Laboratory Mills',#5998,$,$); -#6006=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15 25','Laboratory Presses',#5998,$,$); -#6007=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15 27','Laboratory Pulverizers',#5998,$,$); -#6008=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15 29','Laboratory Tissue Grinders',#5998,$,$); -#6009=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15 31','Liquid Measuring Cans',#5998,$,$); -#6010=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15 33','Mortars',#5998,$,$); -#6011=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15 35','Pestles',#5998,$,$); -#6012=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 17','Laboratory Heating Drying Equipment',#5960,$,$); -#6013=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 17 11','Laboratory Dry Baths',#6012,$,$); -#6014=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 17 13','Bunsen Burner',#6012,$,$); -#6015=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 17 15','Laboratory Hotplates',#6012,$,$); -#6016=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 17 17','Laboratory Incinerators',#6012,$,$); -#6017=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 17 19','Laboratory Infrared Dryers',#6012,$,$); -#6018=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 17 21','Laboratory Spirit Burners',#6012,$,$); -#6019=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 17 23','Laboratory Temperature Cycling Chambers',#6012,$,$); -#6020=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 17 25','Laboratory Thermal Cyclers',#6012,$,$); -#6021=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 17 27','Laboratory Warming Cabinets',#6012,$,$); -#6022=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 17 29','Stirring Hotplates',#6012,$,$); -#6023=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19','Histology Equipment',#5960,$,$); -#6024=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 11','Tissue Embedding Stations',#6023,$,$); -#6025=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 13','Embedding Molds',#6023,$,$); -#6026=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 15','Embedding Capsules',#6023,$,$); -#6027=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 17','Embedding Compounds',#6023,$,$); -#6028=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 19','Histological Staining Units',#6023,$,$); -#6029=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 21','Tissue Processors',#6023,$,$); -#6030=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 21 11','Automatic Tissue Processors',#6029,$,$); -#6031=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 21 13','Electron Microscopy Tissue Processors',#6029,$,$); -#6032=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 21 15','Vacuum Tissue Processors',#6029,$,$); -#6033=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 23','Tissue Culture Units',#6023,$,$); -#6034=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 25','Ultrasonic Tissue Disintegrators',#6023,$,$); -#6035=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 27','Microtomes',#6023,$,$); -#6036=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 27 11','Tilt Rotary Microtomes',#6035,$,$); -#6037=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 27 13','Refrigerated Tilt Rotary Microtomes',#6035,$,$); -#6038=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 29','Slide Warmers',#6023,$,$); -#6039=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 31','Slide Dryers',#6023,$,$); -#6040=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 33','Slide Stainers',#6023,$,$); -#6041=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 21','Laboratory Cooling Equipment',#5960,$,$); -#6042=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 21 11','Liquid Nitrogen Dewars',#6041,$,$); -#6043=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 21 13','Ultra Cold Upright Cabinets',#6041,$,$); -#6044=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 21 15','Ultra Cold Freezers',#6041,$,$); -#6045=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 21 17','Ultralow Upright Cabinets',#6041,$,$); -#6046=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 21 19','Ultralow Freezers',#6041,$,$); -#6047=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 21 21','Ultra Cold Chest Freezers',#6041,$,$); -#6048=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 21 23','Ultralow Chest Freezers',#6041,$,$); -#6049=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 21 25','Liquid Nitrogen Freezers',#6041,$,$); -#6050=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 21 27','Laboratory Cold Water Circulators',#6041,$,$); -#6051=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 21 29','Chromatography Refrigerators',#6041,$,$); -#6052=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 21 31','Laboratory Plate Freezers',#6041,$,$); -#6053=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 21 33','Laboratory Cold Traps',#6041,$,$); -#6054=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23','Centrifuges',#5960,$,$); -#6055=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 11','Benchtop Centrifuges',#6054,$,$); -#6056=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 13','Centrifuge Buckets',#6054,$,$); -#6057=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 15','Centrifuge Rotors',#6054,$,$); -#6058=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 17','Cytology Centrifuges',#6054,$,$); -#6059=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 19','Floor Centrifuges',#6054,$,$); -#6060=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 21','Microcentrifuges',#6054,$,$); -#6061=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 23','Microhematocrit Centrifuges',#6054,$,$); -#6062=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 25','Refrigerated Benchtop Centrifuges',#6054,$,$); -#6063=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 27','Refrigerated Floor Centrifuges',#6054,$,$); -#6064=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 29','Refrigerated Microcentrifuges',#6054,$,$); -#6065=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 31','Serological Centrifuges',#6054,$,$); -#6066=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 31 11','Multiple Speed Serological Centrifuges',#6065,$,$); -#6067=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 33','Tabletop Centrifuges',#6054,$,$); -#6068=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 35','Ultracentrifuges',#6054,$,$); -#6069=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 37','Vacuum Centrifuges',#6054,$,$); -#6070=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25','Incubators',#5960,$,$); -#6071=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 11','CO2 Incubators',#6070,$,$); -#6072=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 13','Cooled Biological Oxygen Demand BOD Incubators',#6070,$,$); -#6073=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 15','Dry Wall Dual Chamber Carbon Dioxide Incubators',#6070,$,$); -#6074=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 17','Dry Wall Dual Chamber Carbon Dioxide Incubators With Humidity Control',#6070,$,$); -#6075=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 19','Dry Wall Dual Chamber Three Gas Incubators',#6070,$,$); -#6076=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 21','Dry Wall Dual Chamber Three Gas Incubators With Humidity Control',#6070,$,$); -#6077=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 23','Dry Wall Single Chamber Carbon Dioxide Incubators',#6070,$,$); -#6078=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 25','Dry Wall Single Chamber Carbon Dioxide Incubators With Humidity Control',#6070,$,$); -#6079=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 27','Dry Wall Single Chamber Three Gas Incubators',#6070,$,$); -#6080=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 29','Dry Wall Single Chamber Three Gas Incubators With Humidity Control',#6070,$,$); -#6081=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 31','Forced Air General Purpose Incubators',#6070,$,$); -#6082=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 33','Gravity Convection General Purpose Incubators',#6070,$,$); -#6083=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 35','Mechanical Convection General Purpose Incubators',#6070,$,$); -#6084=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 37','Multipurpose Incubators',#6070,$,$); -#6085=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 39','Plate Incubators',#6070,$,$); -#6086=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 41','Refrigerated Incubators',#6070,$,$); -#6087=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 43','Shaking Incubators',#6070,$,$); -#6088=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 45','Water Jacketed Dual Chamber Carbon Dioxide Incubators',#6070,$,$); -#6089=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 47','Water Jacketed Dual Chamber Carbon Dioxide Incubators With Humidity Control',#6070,$,$); -#6090=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 49','Water Jacketed Dual Chamber Three Gas Incubators',#6070,$,$); -#6091=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 51','Water Jacketed Dual Chamber Three Gas Incubators With Humidity Control',#6070,$,$); -#6092=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 53','Water Jacketed Single Chamber Carbon Dioxide Incubators',#6070,$,$); -#6093=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 55','Water Jacketed Single Chamber Carbon Dioxide Incubators With Humidity Control',#6070,$,$); -#6094=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 57','Water Jacketed Single Chamber Three Gas Incubators',#6070,$,$); -#6095=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 59','Water Jacketed Single Chamber Three Gas Incubators With Humidity Control',#6070,$,$); -#6096=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 27','Laboratory Ovens',#5960,$,$); -#6097=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 27 11','Laboratory Ageing Ovens',#6096,$,$); -#6098=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 27 13','Laboratory Cleanroom Ovens',#6096,$,$); -#6099=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 27 15','Laboratory Drying Cabinets',#6096,$,$); -#6100=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 27 17','Laboratory Drying Ovens',#6096,$,$); -#6101=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 27 19','Laboratory Gravity Convection Ovens',#6096,$,$); -#6102=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 27 21','Laboratory Induction Dryers',#6096,$,$); -#6103=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 27 23','Laboratory Mechanical Convection Ovens',#6096,$,$); -#6104=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 27 25','Laboratory Vacuum Ovens',#6096,$,$); -#6105=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 29','Laboratory Distillers',#5960,$,$); -#6106=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 29 11','Laboratory Water Distillers',#6105,$,$); -#6107=IFCCLASSIFICATIONREFERENCE($,'23-27 00 00','General Facility Services Products',#1604,$,$); -#6108=IFCCLASSIFICATIONREFERENCE($,'23-27 11 00','General Instruments and Controls',#6107,$,$); -#6109=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11','Temperature Measuring Instrument And Controls',#6108,$,$); -#6110=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 11','Temperature Alarm Modules',#6109,$,$); -#6111=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 13','Temperature Control Modules',#6109,$,$); -#6112=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 15','Temperature Controllers',#6109,$,$); -#6113=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 15 11','Digital Temperature Controllers',#6112,$,$); -#6114=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 15 13','Electric Temperature Controllers',#6112,$,$); -#6115=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 15 15','Pneumatic Hating Controllers',#6112,$,$); -#6116=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 15 17','Hydraulic Temperature Controllers',#6112,$,$); -#6117=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 17','Temperature Detectors',#6109,$,$); -#6118=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 17 11','Thermocouple Detectors',#6117,$,$); -#6119=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 17 13','RTD Detectors',#6117,$,$); -#6120=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 19','Temperature Indicators',#6109,$,$); -#6121=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 21','Temperature Recorders',#6109,$,$); -#6122=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 23','Temperature Sensors',#6109,$,$); -#6123=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 23 11','Thermocouple Probes',#6122,$,$); -#6124=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13','Pressure Measuring Instrument And Controls',#6108,$,$); -#6125=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 11','Pressure Alarm Modules',#6124,$,$); -#6126=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 13','Pressure Control Modules',#6124,$,$); -#6127=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 15','Pressure Controllers',#6124,$,$); -#6128=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 15 11','Digital Pressure Controllers',#6127,$,$); -#6129=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 15 13','Electric Pressure Controllers',#6127,$,$); -#6130=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 15 15','Pneumatic Hating Controllers',#6127,$,$); -#6131=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 15 17','Hydraulic Pressure Controllers',#6127,$,$); -#6132=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 17','Pressure Detectors',#6124,$,$); -#6133=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 19','Pressure Indicators',#6124,$,$); -#6134=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 21','Pressure Recorders',#6124,$,$); -#6135=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 23','Pressure Sensors',#6124,$,$); -#6136=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 25','Differential Pressure Alarm Modules',#6124,$,$); -#6137=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 27','Differential Pressure Control Modules',#6124,$,$); -#6138=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 29','Differential Pressure Controllers',#6124,$,$); -#6139=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 29 11','Digital Differential Pressure Controllers',#6138,$,$); -#6140=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 29 13','Electric Differential Pressure Controllers',#6138,$,$); -#6141=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 29 15','Pneumatic Hating Controllers',#6138,$,$); -#6142=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 29 17','Hydraulic Differential Pressure Controllers',#6138,$,$); -#6143=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 31','Differential Pressure Detectors',#6124,$,$); -#6144=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 33','Differential Pressure Indicators',#6124,$,$); -#6145=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 35','Differential Pressure Recorders',#6124,$,$); -#6146=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 37','Differential Pressure Sensors',#6124,$,$); -#6147=IFCCLASSIFICATIONREFERENCE($,'23-27 11 15','Flow Measuring Instrument And Controls',#6108,$,$); -#6148=IFCCLASSIFICATIONREFERENCE($,'23-27 11 15 11','Flow Alarm Modules',#6147,$,$); -#6149=IFCCLASSIFICATIONREFERENCE($,'23-27 11 15 13','Flow Control Modules',#6147,$,$); -#6150=IFCCLASSIFICATIONREFERENCE($,'23-27 11 15 15','Flow Controllers',#6147,$,$); -#6151=IFCCLASSIFICATIONREFERENCE($,'23-27 11 15 15 11','Digital Flow Controllers',#6150,$,$); -#6152=IFCCLASSIFICATIONREFERENCE($,'23-27 11 15 15 13','Electric Flow Controllers',#6150,$,$); -#6153=IFCCLASSIFICATIONREFERENCE($,'23-27 11 15 15 15','Pneumatic Hating Controllers',#6150,$,$); -#6154=IFCCLASSIFICATIONREFERENCE($,'23-27 11 15 15 17','Hydraulic Flow Controllers',#6150,$,$); -#6155=IFCCLASSIFICATIONREFERENCE($,'23-27 11 15 17','Flow Detectors',#6147,$,$); -#6156=IFCCLASSIFICATIONREFERENCE($,'23-27 11 15 19','Flow Indicators',#6147,$,$); -#6157=IFCCLASSIFICATIONREFERENCE($,'23-27 11 15 21','Flow Recorders',#6147,$,$); -#6158=IFCCLASSIFICATIONREFERENCE($,'23-27 11 15 23','Flow Sensors',#6147,$,$); -#6159=IFCCLASSIFICATIONREFERENCE($,'23-27 11 17','Concentration Measuring Instrument And Controls',#6108,$,$); -#6160=IFCCLASSIFICATIONREFERENCE($,'23-27 11 17 11','Humidity Concentration Measuring Instruments',#6159,$,$); -#6161=IFCCLASSIFICATIONREFERENCE($,'23-27 11 17 13','Carbon Dioxide (CO\X2\00B2\X0\) Concentration Measuring Instruments',#6159,$,$); -#6162=IFCCLASSIFICATIONREFERENCE($,'23-27 11 17 15','Ozone Concentration Measuring Instruments',#6159,$,$); -#6163=IFCCLASSIFICATIONREFERENCE($,'23-27 11 17 17','Other Gas Concentration Measuring Instruments',#6159,$,$); -#6164=IFCCLASSIFICATIONREFERENCE($,'23-27 11 19','Heat Measuring Instrument And Controls',#6108,$,$); -#6165=IFCCLASSIFICATIONREFERENCE($,'23-27 11 19 11','Heat Detectors',#6164,$,$); -#6166=IFCCLASSIFICATIONREFERENCE($,'23-27 11 19 13','Heating Controllers',#6164,$,$); -#6167=IFCCLASSIFICATIONREFERENCE($,'23-27 11 19 13 11','Digital Heating Controllers',#6166,$,$); -#6168=IFCCLASSIFICATIONREFERENCE($,'23-27 11 19 13 13','Electric Heating Controllers',#6166,$,$); -#6169=IFCCLASSIFICATIONREFERENCE($,'23-27 11 19 13 15','Pneumatic Hating Controllers',#6166,$,$); -#6170=IFCCLASSIFICATIONREFERENCE($,'23-27 11 19 13 17','Hydraulic Heating Controllers',#6166,$,$); -#6171=IFCCLASSIFICATIONREFERENCE($,'23-27 11 19 15','Heating Programmers',#6164,$,$); -#6172=IFCCLASSIFICATIONREFERENCE($,'23-27 11 19 17','Heating Optimizers',#6164,$,$); -#6173=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21','Level Measuring Instrument And Controls',#6108,$,$); -#6174=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21 11','Level Alarm Modules',#6173,$,$); -#6175=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21 13','Level Control Modules',#6173,$,$); -#6176=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21 15','Level Controllers',#6173,$,$); -#6177=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21 15 11','Digital Level Controllers',#6176,$,$); -#6178=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21 15 13','Electric Level Controllers',#6176,$,$); -#6179=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21 15 15','Pneumatic Hating Controllers',#6176,$,$); -#6180=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21 15 17','Hydraulic Level Controllers',#6176,$,$); -#6181=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21 17','Level Detectors',#6173,$,$); -#6182=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21 19','Level Indicators',#6173,$,$); -#6183=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21 19 11','Level Gage Glasses',#6182,$,$); -#6184=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21 19 13','Level Bull''s Eyes',#6182,$,$); -#6185=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21 21','Level Recorders',#6173,$,$); -#6186=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21 23','Level Sensors',#6173,$,$); -#6187=IFCCLASSIFICATIONREFERENCE($,'23-27 11 23','Weighing Instrument And Controls',#6108,$,$); -#6188=IFCCLASSIFICATIONREFERENCE($,'23-27 11 23 11','Weight Alarm Modules',#6187,$,$); -#6189=IFCCLASSIFICATIONREFERENCE($,'23-27 11 23 13','Weight Control Modules',#6187,$,$); -#6190=IFCCLASSIFICATIONREFERENCE($,'23-27 11 23 15','Weight Detectors',#6187,$,$); -#6191=IFCCLASSIFICATIONREFERENCE($,'23-27 11 23 17','Weight Indicators',#6187,$,$); -#6192=IFCCLASSIFICATIONREFERENCE($,'23-27 11 23 19','Weight Recorders',#6187,$,$); -#6193=IFCCLASSIFICATIONREFERENCE($,'23-27 11 23 21','Weight Sensors',#6187,$,$); -#6194=IFCCLASSIFICATIONREFERENCE($,'23-27 11 25','Metal Concentration Instrument And Controls',#6108,$,$); -#6195=IFCCLASSIFICATIONREFERENCE($,'23-27 11 25 11','Metal Detectors',#6194,$,$); -#6196=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27','Gas Instrument And Controls',#6108,$,$); -#6197=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 11','Gas Alarm Modules',#6196,$,$); -#6198=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 13','Gas Control Modules',#6196,$,$); -#6199=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 15','Gas Controllers',#6196,$,$); -#6200=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 15 11','Digital Gas Controllers',#6199,$,$); -#6201=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 15 13','Electric Gas Controllers',#6199,$,$); -#6202=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 15 15','Pneumatic Hating Controllers',#6199,$,$); -#6203=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 15 17','Hydraulic Gas Controllers',#6199,$,$); -#6204=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 17','Gas Detectors',#6196,$,$); -#6205=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 17 11','Air Pollution Detectors',#6204,$,$); -#6206=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 17 13','Radon Detectors',#6204,$,$); -#6207=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 17 15','Carbon Dioxide Detectors',#6204,$,$); -#6208=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 17 17','Hydrogen Detectors',#6204,$,$); -#6209=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 17 19','Oxygen Detectors',#6204,$,$); -#6210=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 17 21','Halon Detectors',#6204,$,$); -#6211=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 19','Gas Indicators',#6196,$,$); -#6212=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 21','Gas Analyzers',#6196,$,$); -#6213=IFCCLASSIFICATIONREFERENCE($,'23-27 11 29','Infrared Instrument And Controls',#6108,$,$); -#6214=IFCCLASSIFICATIONREFERENCE($,'23-27 11 29 11','Photoelectric Cells',#6213,$,$); -#6215=IFCCLASSIFICATIONREFERENCE($,'23-27 11 29 13','Infrared Control Modules',#6213,$,$); -#6216=IFCCLASSIFICATIONREFERENCE($,'23-27 11 29 15','Infrared Controllers',#6213,$,$); -#6217=IFCCLASSIFICATIONREFERENCE($,'23-27 11 29 15 11','Digital Infrared Controllers',#6216,$,$); -#6218=IFCCLASSIFICATIONREFERENCE($,'23-27 11 29 15 13','Electric Infrared Controllers',#6216,$,$); -#6219=IFCCLASSIFICATIONREFERENCE($,'23-27 11 29 15 15','Pneumatic Hating Controllers',#6216,$,$); -#6220=IFCCLASSIFICATIONREFERENCE($,'23-27 11 29 15 17','Hydraulic Infrared Controllers',#6216,$,$); -#6221=IFCCLASSIFICATIONREFERENCE($,'23-27 13 00','Control and Monitoring Boards Panels',#6107,$,$); -#6222=IFCCLASSIFICATIONREFERENCE($,'23-27 13 11','Internal Climate Monitoring and Control Panel',#6221,$,$); -#6223=IFCCLASSIFICATIONREFERENCE($,'23-27 13 13','Building Control Systems',#6221,$,$); -#6224=IFCCLASSIFICATIONREFERENCE($,'23-27 13 13 11','Building Automated Control Panels',#6223,$,$); -#6225=IFCCLASSIFICATIONREFERENCE($,'23-27 13 13 13','Building Automated Systems',#6223,$,$); -#6226=IFCCLASSIFICATIONREFERENCE($,'23-27 13 13 15','Building Monitoring Control Panels',#6223,$,$); -#6227=IFCCLASSIFICATIONREFERENCE($,'23-27 13 15','Process Control Panels',#6221,$,$); -#6228=IFCCLASSIFICATIONREFERENCE($,'23-27 13 15 11','Gaseous Waste Monitoring and Control Panels',#6227,$,$); -#6229=IFCCLASSIFICATIONREFERENCE($,'23-27 15 00','Building Automation and Control',#6107,$,$); -#6230=IFCCLASSIFICATIONREFERENCE($,'23-27 15 11','Building Clock Controls',#6229,$,$); -#6231=IFCCLASSIFICATIONREFERENCE($,'23-27 15 13','Building Door Controls',#6229,$,$); -#6232=IFCCLASSIFICATIONREFERENCE($,'23-27 15 15','Elevator Monitoring and Controls',#6229,$,$); -#6233=IFCCLASSIFICATIONREFERENCE($,'23-27 15 17','Energy Monitoring and Controls',#6229,$,$); -#6234=IFCCLASSIFICATIONREFERENCE($,'23-27 15 19','Building Environmental Controls',#6229,$,$); -#6235=IFCCLASSIFICATIONREFERENCE($,'23-27 15 21','Building Lighting Controls',#6229,$,$); -#6236=IFCCLASSIFICATIONREFERENCE($,'23-27 15 21 11','Building Lighting Control Panel',#6235,$,$); -#6237=IFCCLASSIFICATIONREFERENCE($,'23-27 15 21 13','Lighting Relay Control Panel',#6235,$,$); -#6238=IFCCLASSIFICATIONREFERENCE($,'23-27 15 23','HVAC Controls',#6229,$,$); -#6239=IFCCLASSIFICATIONREFERENCE($,'23-27 15 23 11','HVAC Main Control Panels',#6238,$,$); -#6240=IFCCLASSIFICATIONREFERENCE($,'23-27 15 23 13','HVAC Local Control Panels',#6238,$,$); -#6241=IFCCLASSIFICATIONREFERENCE($,'23-27 15 23 15','HVAC Control Clocks',#6238,$,$); -#6242=IFCCLASSIFICATIONREFERENCE($,'23-27 15 25','Equipment Control Panels',#6229,$,$); -#6243=IFCCLASSIFICATIONREFERENCE($,'23-27 17 00','Pumps',#6107,$,$); -#6244=IFCCLASSIFICATIONREFERENCE($,'23-27 17 11','Axial Split Pumps',#6243,$,$); -#6245=IFCCLASSIFICATIONREFERENCE($,'23-27 17 13','Centrifugal Pumps',#6243,$,$); -#6246=IFCCLASSIFICATIONREFERENCE($,'23-27 17 15','Diaphragm Pumps',#6243,$,$); -#6247=IFCCLASSIFICATIONREFERENCE($,'23-27 17 17','Duplex Pumps',#6243,$,$); -#6248=IFCCLASSIFICATIONREFERENCE($,'23-27 17 19','Gear Pumps',#6243,$,$); -#6249=IFCCLASSIFICATIONREFERENCE($,'23-27 17 21','Liquid Ring Pumps',#6243,$,$); -#6250=IFCCLASSIFICATIONREFERENCE($,'23-27 17 23','Macerator Pumps',#6243,$,$); -#6251=IFCCLASSIFICATIONREFERENCE($,'23-27 17 23 11','Combined Macerator Pumps',#6250,$,$); -#6252=IFCCLASSIFICATIONREFERENCE($,'23-27 17 25','Progressive Cavity Pumps',#6243,$,$); -#6253=IFCCLASSIFICATIONREFERENCE($,'23-27 17 27','Ram Pumps',#6243,$,$); -#6254=IFCCLASSIFICATIONREFERENCE($,'23-27 17 29','Reciprocating Pumps',#6243,$,$); -#6255=IFCCLASSIFICATIONREFERENCE($,'23-27 17 31','Rotary Pumps',#6243,$,$); -#6256=IFCCLASSIFICATIONREFERENCE($,'23-27 17 31 11','Rotary Cam Pumps',#6255,$,$); -#6257=IFCCLASSIFICATIONREFERENCE($,'23-27 17 31 13','Rotary Lobe Pumps',#6255,$,$); -#6258=IFCCLASSIFICATIONREFERENCE($,'23-27 17 31 15','Rotary Screw Pumps',#6255,$,$); -#6259=IFCCLASSIFICATIONREFERENCE($,'23-27 17 31 17','Rotary Vane Pumps',#6255,$,$); -#6260=IFCCLASSIFICATIONREFERENCE($,'23-27 17 33','Rotating Piston Pumps',#6243,$,$); -#6261=IFCCLASSIFICATIONREFERENCE($,'23-27 17 35','Sewage Ejectors',#6243,$,$); -#6262=IFCCLASSIFICATIONREFERENCE($,'23-27 17 35 11','Submersible Sewage Ejectors',#6261,$,$); -#6263=IFCCLASSIFICATIONREFERENCE($,'23-27 17 37','Simplex Pumps',#6243,$,$); -#6264=IFCCLASSIFICATIONREFERENCE($,'23-27 17 39','Sliding Vane Pumps',#6243,$,$); -#6265=IFCCLASSIFICATIONREFERENCE($,'23-27 17 41','Turbine Pumps',#6243,$,$); -#6266=IFCCLASSIFICATIONREFERENCE($,'23-27 17 43','Worm Gear Pumps',#6243,$,$); -#6267=IFCCLASSIFICATIONREFERENCE($,'23-27 17 45','Pump Components',#6243,$,$); -#6268=IFCCLASSIFICATIONREFERENCE($,'23-27 19 00','Engines',#6107,$,$); -#6269=IFCCLASSIFICATIONREFERENCE($,'23-27 19 11','Reciprocating Engines',#6268,$,$); -#6270=IFCCLASSIFICATIONREFERENCE($,'23-27 19 13','Rotary Engines',#6268,$,$); -#6271=IFCCLASSIFICATIONREFERENCE($,'23-27 19 15','Turbine Engines',#6268,$,$); -#6272=IFCCLASSIFICATIONREFERENCE($,'23-27 21 00','Compressors',#6107,$,$); -#6273=IFCCLASSIFICATIONREFERENCE($,'23-27 21 11','Axial Flow Compressors',#6272,$,$); -#6274=IFCCLASSIFICATIONREFERENCE($,'23-27 21 13','Centrifugal Compressors',#6272,$,$); -#6275=IFCCLASSIFICATIONREFERENCE($,'23-27 21 15','Reciprocating Compressors',#6272,$,$); -#6276=IFCCLASSIFICATIONREFERENCE($,'23-27 21 15 11','Diaphragm Reciprocating Compressors',#6275,$,$); -#6277=IFCCLASSIFICATIONREFERENCE($,'23-27 21 15 13','Double Acting Reciprocating Compressors',#6275,$,$); -#6278=IFCCLASSIFICATIONREFERENCE($,'23-27 21 15 15','Single Acting Reciprocating Compressors',#6275,$,$); -#6279=IFCCLASSIFICATIONREFERENCE($,'23-27 21 17','Rotary Compressors',#6272,$,$); -#6280=IFCCLASSIFICATIONREFERENCE($,'23-27 21 17 11','Rotary Liquid Ring Compressors',#6279,$,$); -#6281=IFCCLASSIFICATIONREFERENCE($,'23-27 21 17 13','Rotary Lobe Compressors',#6279,$,$); -#6282=IFCCLASSIFICATIONREFERENCE($,'23-27 21 17 15','Rotary Screw Compressors',#6279,$,$); -#6283=IFCCLASSIFICATIONREFERENCE($,'23-27 21 17 17','Rotary Scroll Compressors',#6279,$,$); -#6284=IFCCLASSIFICATIONREFERENCE($,'23-27 21 17 19','Rotary Vane Compressors',#6279,$,$); -#6285=IFCCLASSIFICATIONREFERENCE($,'23-27 23 00','Heat Exchangers',#6107,$,$); -#6286=IFCCLASSIFICATIONREFERENCE($,'23-27 23 11','Heat Exchanger Economizers',#6285,$,$); -#6287=IFCCLASSIFICATIONREFERENCE($,'23-27 23 13','Plate and Frame Heat Exchangers',#6285,$,$); -#6288=IFCCLASSIFICATIONREFERENCE($,'23-27 23 13 11','Plate and Frame Regenerative Heat Exchangers',#6287,$,$); -#6289=IFCCLASSIFICATIONREFERENCE($,'23-27 23 15','Shell and Tube Heat Exchangers',#6285,$,$); -#6290=IFCCLASSIFICATIONREFERENCE($,'23-27 23 15 11','Shell and Tube Regenerative Heat Exchangers',#6289,$,$); -#6291=IFCCLASSIFICATIONREFERENCE($,'23-27 23 17','Tube and Fin Heat Exchangers',#6285,$,$); -#6292=IFCCLASSIFICATIONREFERENCE($,'23-27 23 19','Spiral Heat Exchangers',#6285,$,$); -#6293=IFCCLASSIFICATIONREFERENCE($,'23-27 23 19 11','Heat Exchangers for Ventilation Air',#6292,$,$); -#6294=IFCCLASSIFICATIONREFERENCE($,'23-27 23 21','Adiabatic Wheel Heat Exchangers',#6285,$,$); -#6295=IFCCLASSIFICATIONREFERENCE($,'23-27 23 23','Plate and Fin Heat Exchangers',#6285,$,$); -#6296=IFCCLASSIFICATIONREFERENCE($,'23-27 23 23 11','Straight Fin Plate and Fin Heat Exchangers',#6295,$,$); -#6297=IFCCLASSIFICATIONREFERENCE($,'23-27 23 23 13','Offset Fin Plate and Fin Heat Exchangers',#6295,$,$); -#6298=IFCCLASSIFICATIONREFERENCE($,'23-27 23 23 15','Wavy Fin Plate and Fin Heat Exchangers',#6295,$,$); -#6299=IFCCLASSIFICATIONREFERENCE($,'23-27 23 25','Fluid Heat Exchangers',#6285,$,$); -#6300=IFCCLASSIFICATIONREFERENCE($,'23-27 25 00','Heaters for Supplied Liquids',#6107,$,$); -#6301=IFCCLASSIFICATIONREFERENCE($,'23-27 25 11','Liquid Electric Heaters',#6300,$,$); -#6302=IFCCLASSIFICATIONREFERENCE($,'23-27 25 13','Liquid Gas Heaters',#6300,$,$); -#6303=IFCCLASSIFICATIONREFERENCE($,'23-27 25 15','Liquid Steam Heaters',#6300,$,$); -#6304=IFCCLASSIFICATIONREFERENCE($,'23-27 25 17','Liquid Fuel Oil Heaters',#6300,$,$); -#6305=IFCCLASSIFICATIONREFERENCE($,'23-27 25 17 11','Fuel Oil Pre Heaters',#6304,$,$); -#6306=IFCCLASSIFICATIONREFERENCE($,'23-27 27 00','Pressure Reducing Stations',#6107,$,$); -#6307=IFCCLASSIFICATIONREFERENCE($,'23-27 27 11','Multiple Stage Pressure Reducing Stations',#6306,$,$); -#6308=IFCCLASSIFICATIONREFERENCE($,'23-27 27 13','Single Stage Pressure Reducing Stations',#6306,$,$); -#6309=IFCCLASSIFICATIONREFERENCE($,'23-27 29 00','Tanks and Storage Structures',#6107,$,$); -#6310=IFCCLASSIFICATIONREFERENCE($,'23-27 29 11','Reservoirs',#6309,$,$); -#6311=IFCCLASSIFICATIONREFERENCE($,'23-27 29 13','Tank Foundations',#6309,$,$); -#6312=IFCCLASSIFICATIONREFERENCE($,'23-27 29 13 11','Tank Support Structures',#6311,$,$); -#6313=IFCCLASSIFICATIONREFERENCE($,'23-27 29 13 13','Tank Foundation Slabs',#6311,$,$); -#6314=IFCCLASSIFICATIONREFERENCE($,'23-27 29 15','Specialized Tanks',#6309,$,$); -#6315=IFCCLASSIFICATIONREFERENCE($,'23-27 29 15 11','Cryogenic Tanks',#6314,$,$); -#6316=IFCCLASSIFICATIONREFERENCE($,'23-27 29 15 13','Flash Tanks',#6314,$,$); -#6317=IFCCLASSIFICATIONREFERENCE($,'23-27 29 15 13 11','Steam Flash Tanks',#6316,$,$); -#6318=IFCCLASSIFICATIONREFERENCE($,'23-27 29 15 15','Septic Tanks',#6314,$,$); -#6319=IFCCLASSIFICATIONREFERENCE($,'23-27 29 15 17','Siphon Tanks',#6314,$,$); -#6320=IFCCLASSIFICATIONREFERENCE($,'23-27 29 17','Storage Constructions',#6309,$,$); -#6321=IFCCLASSIFICATIONREFERENCE($,'23-27 29 17 11','Water Towers',#6320,$,$); -#6322=IFCCLASSIFICATIONREFERENCE($,'23-27 29 17 13','Silos',#6320,$,$); -#6323=IFCCLASSIFICATIONREFERENCE($,'23-27 29 17 15','Storage Bunkers',#6320,$,$); -#6324=IFCCLASSIFICATIONREFERENCE($,'23-27 29 19','Tanks',#6309,$,$); -#6325=IFCCLASSIFICATIONREFERENCE($,'23-27 29 19 11','Multiple Wall Tanks',#6324,$,$); -#6326=IFCCLASSIFICATIONREFERENCE($,'23-27 29 19 11 11','Multiple Walled Pressure Tanks',#6325,$,$); -#6327=IFCCLASSIFICATIONREFERENCE($,'23-27 29 19 11 13','Multiple Walled Vacuum Tanks',#6325,$,$); -#6328=IFCCLASSIFICATIONREFERENCE($,'23-27 29 19 11 15','Multiple Walled Vented Tanks',#6325,$,$); -#6329=IFCCLASSIFICATIONREFERENCE($,'23-27 29 19 13','Single Walled Tanks',#6324,$,$); -#6330=IFCCLASSIFICATIONREFERENCE($,'23-27 29 19 13 11','Single Walled Pressure Tanks',#6329,$,$); -#6331=IFCCLASSIFICATIONREFERENCE($,'23-27 29 19 13 13','Single Walled Vacuum Tanks',#6329,$,$); -#6332=IFCCLASSIFICATIONREFERENCE($,'23-27 29 19 13 15','Single Walled Vented Tanks',#6329,$,$); -#6333=IFCCLASSIFICATIONREFERENCE($,'23-27 29 21','Tank Containments',#6309,$,$); -#6334=IFCCLASSIFICATIONREFERENCE($,'23-27 29 21 11','Aboveground Tank Containments',#6333,$,$); -#6335=IFCCLASSIFICATIONREFERENCE($,'23-27 29 21 11 11','Aboveground Primary Tank Containments',#6334,$,$); -#6336=IFCCLASSIFICATIONREFERENCE($,'23-27 29 21 11 13','Aboveground Secondary Tank Containments',#6334,$,$); -#6337=IFCCLASSIFICATIONREFERENCE($,'23-27 29 21 11 15','Aboveground Tertiary Tank Containments',#6334,$,$); -#6338=IFCCLASSIFICATIONREFERENCE($,'23-27 29 21 13','Underground Tank Containments',#6333,$,$); -#6339=IFCCLASSIFICATIONREFERENCE($,'23-27 29 21 13 11','Underground Primary Tank Containments',#6338,$,$); -#6340=IFCCLASSIFICATIONREFERENCE($,'23-27 29 21 13 13','Underground Secondary Tank Containments',#6338,$,$); -#6341=IFCCLASSIFICATIONREFERENCE($,'23-27 29 21 13 15','Underground Tertiary Tank Containments',#6338,$,$); -#6342=IFCCLASSIFICATIONREFERENCE($,'23-27 29 23','Tank Linings',#6309,$,$); -#6343=IFCCLASSIFICATIONREFERENCE($,'23-27 29 23 11','Tank Bladders',#6342,$,$); -#6344=IFCCLASSIFICATIONREFERENCE($,'23-27 29 23 13','Rubber Tank Linings',#6342,$,$); -#6345=IFCCLASSIFICATIONREFERENCE($,'23-27 29 25','Tank Components',#6309,$,$); -#6346=IFCCLASSIFICATIONREFERENCE($,'23-27 29 25 11','Overflow Regulators',#6345,$,$); -#6347=IFCCLASSIFICATIONREFERENCE($,'23-27 29 25 13','Fill and Valve Caps',#6345,$,$); -#6348=IFCCLASSIFICATIONREFERENCE($,'23-27 29 25 15','Tank Vents',#6345,$,$); -#6349=IFCCLASSIFICATIONREFERENCE($,'23-27 31 00','Valves',#6107,$,$); -#6350=IFCCLASSIFICATIONREFERENCE($,'23-27 31 11','Backflow Preventors',#6349,$,$); -#6351=IFCCLASSIFICATIONREFERENCE($,'23-27 31 13','Balancing Valves',#6349,$,$); -#6352=IFCCLASSIFICATIONREFERENCE($,'23-27 31 13 11','Gate Balancing Valves',#6351,$,$); -#6353=IFCCLASSIFICATIONREFERENCE($,'23-27 31 13 13','Butterfly Balancing Valves',#6351,$,$); -#6354=IFCCLASSIFICATIONREFERENCE($,'23-27 31 13 15','Plug Balancing Valves',#6351,$,$); -#6355=IFCCLASSIFICATIONREFERENCE($,'23-27 31 13 17','Globe Balancing Valves',#6351,$,$); -#6356=IFCCLASSIFICATIONREFERENCE($,'23-27 31 13 19','Check Balancing Valves',#6351,$,$); -#6357=IFCCLASSIFICATIONREFERENCE($,'23-27 31 13 21','Diaphragm Balancing Valves',#6351,$,$); -#6358=IFCCLASSIFICATIONREFERENCE($,'23-27 31 15','Ball Valves',#6349,$,$); -#6359=IFCCLASSIFICATIONREFERENCE($,'23-27 31 17','Butterfly Valves',#6349,$,$); -#6360=IFCCLASSIFICATIONREFERENCE($,'23-27 31 17 11','Lug Pattern Butterfly Valves',#6359,$,$); -#6361=IFCCLASSIFICATIONREFERENCE($,'23-27 31 17 13','Wafer Pattern Butterfly Valves',#6359,$,$); -#6362=IFCCLASSIFICATIONREFERENCE($,'23-27 31 19','Check Valves',#6349,$,$); -#6363=IFCCLASSIFICATIONREFERENCE($,'23-27 31 19 11','Ball Check Valves',#6362,$,$); -#6364=IFCCLASSIFICATIONREFERENCE($,'23-27 31 19 13','Clapper CheckValves',#6362,$,$); -#6365=IFCCLASSIFICATIONREFERENCE($,'23-27 31 19 15','Cone Type Check Valves',#6362,$,$); -#6366=IFCCLASSIFICATIONREFERENCE($,'23-27 31 19 17','Demand Check Valves',#6362,$,$); -#6367=IFCCLASSIFICATIONREFERENCE($,'23-27 31 19 19','Diaphragm Check Valves',#6362,$,$); -#6368=IFCCLASSIFICATIONREFERENCE($,'23-27 31 19 21','Lift Check Valves',#6362,$,$); -#6369=IFCCLASSIFICATIONREFERENCE($,'23-27 31 19 23','Spring Type Check Valves',#6362,$,$); -#6370=IFCCLASSIFICATIONREFERENCE($,'23-27 31 19 25','Stop Check Valves',#6362,$,$); -#6371=IFCCLASSIFICATIONREFERENCE($,'23-27 31 19 27','Swing Check Valves',#6362,$,$); -#6372=IFCCLASSIFICATIONREFERENCE($,'23-27 31 21','Diaphragm Valves',#6349,$,$); -#6373=IFCCLASSIFICATIONREFERENCE($,'23-27 31 23','Float Valves',#6349,$,$); -#6374=IFCCLASSIFICATIONREFERENCE($,'23-27 31 25','Gate Valves',#6349,$,$); -#6375=IFCCLASSIFICATIONREFERENCE($,'23-27 31 27','Globe Valves',#6349,$,$); -#6376=IFCCLASSIFICATIONREFERENCE($,'23-27 31 29','Mixing Valves',#6349,$,$); -#6377=IFCCLASSIFICATIONREFERENCE($,'23-27 31 29 11','Manual Mixing Valves',#6376,$,$); -#6378=IFCCLASSIFICATIONREFERENCE($,'23-27 31 29 13','Pressure Balanced Controlled Mixing Valves',#6376,$,$); -#6379=IFCCLASSIFICATIONREFERENCE($,'23-27 31 29 15','Thermostatically Controlled Mixing Valves',#6376,$,$); -#6380=IFCCLASSIFICATIONREFERENCE($,'23-27 31 31','Needle Valves',#6349,$,$); -#6381=IFCCLASSIFICATIONREFERENCE($,'23-27 31 33','Orifice Valves',#6349,$,$); -#6382=IFCCLASSIFICATIONREFERENCE($,'23-27 31 35','Pinch Valves',#6349,$,$); -#6383=IFCCLASSIFICATIONREFERENCE($,'23-27 31 37','Plug Drain Valves',#6349,$,$); -#6384=IFCCLASSIFICATIONREFERENCE($,'23-27 31 39','Plug Valves',#6349,$,$); -#6385=IFCCLASSIFICATIONREFERENCE($,'23-27 31 41','Poppet Valves',#6349,$,$); -#6386=IFCCLASSIFICATIONREFERENCE($,'23-27 31 43','Post Indicator Valves',#6349,$,$); -#6387=IFCCLASSIFICATIONREFERENCE($,'23-27 31 45','Preaction Valves',#6349,$,$); -#6388=IFCCLASSIFICATIONREFERENCE($,'23-27 31 45 11','Electronic Actuated Preaction Valves',#6387,$,$); -#6389=IFCCLASSIFICATIONREFERENCE($,'23-27 31 45 13','Water Seal Enabled Preaction Valves',#6387,$,$); -#6390=IFCCLASSIFICATIONREFERENCE($,'23-27 31 47','Pressure Regulating Valves',#6349,$,$); -#6391=IFCCLASSIFICATIONREFERENCE($,'23-27 31 49','Relief Valves',#6349,$,$); -#6392=IFCCLASSIFICATIONREFERENCE($,'23-27 31 49 11','Pressure Relief Valves',#6391,$,$); -#6393=IFCCLASSIFICATIONREFERENCE($,'23-27 31 49 13','Pressure Temperature Relief Valves',#6391,$,$); -#6394=IFCCLASSIFICATIONREFERENCE($,'23-27 31 51','Rupture Disks',#6349,$,$); -#6395=IFCCLASSIFICATIONREFERENCE($,'23-27 31 53','Safety Valves',#6349,$,$); -#6396=IFCCLASSIFICATIONREFERENCE($,'23-27 31 53 11','Pressure Safety Valves',#6395,$,$); -#6397=IFCCLASSIFICATIONREFERENCE($,'23-27 31 53 13','Pressure Temperature Safety Valves',#6395,$,$); -#6398=IFCCLASSIFICATIONREFERENCE($,'23-27 31 55','Sentinel Valves',#6349,$,$); -#6399=IFCCLASSIFICATIONREFERENCE($,'23-27 31 57','Slider Valves',#6349,$,$); -#6400=IFCCLASSIFICATIONREFERENCE($,'23-27 31 59','Slush Valves',#6349,$,$); -#6401=IFCCLASSIFICATIONREFERENCE($,'23-27 31 61','Thermostatic Expansion Valves',#6349,$,$); -#6402=IFCCLASSIFICATIONREFERENCE($,'23-27 31 63','Valves Boxes',#6349,$,$); -#6403=IFCCLASSIFICATIONREFERENCE($,'23-27 33 00','Valve Actuators',#6107,$,$); -#6404=IFCCLASSIFICATIONREFERENCE($,'23-27 33 11','Electrical Valve Actuators',#6403,$,$); -#6405=IFCCLASSIFICATIONREFERENCE($,'23-27 33 11 11','Solenoid Valve Actuators',#6404,$,$); -#6406=IFCCLASSIFICATIONREFERENCE($,'23-27 33 13','Hydraulic Valve Actuators',#6403,$,$); -#6407=IFCCLASSIFICATIONREFERENCE($,'23-27 33 15','Motor Operated Valve Actuators',#6403,$,$); -#6408=IFCCLASSIFICATIONREFERENCE($,'23-27 33 17','Pneumatic Valve Actuators',#6403,$,$); -#6409=IFCCLASSIFICATIONREFERENCE($,'23-27 35 00','Variable Speed Drives',#6107,$,$); -#6410=IFCCLASSIFICATIONREFERENCE($,'23-27 35 11','Hydraulic Variable Speed Drives',#6409,$,$); -#6411=IFCCLASSIFICATIONREFERENCE($,'23-27 35 11 11','Hydrodynamic Variable Speed Drives',#6410,$,$); -#6412=IFCCLASSIFICATIONREFERENCE($,'23-27 35 11 13','Hydrostatic Variable Speed Drives',#6410,$,$); -#6413=IFCCLASSIFICATIONREFERENCE($,'23-27 35 11 15','Hydroviscous Variable Speed Drives',#6410,$,$); -#6414=IFCCLASSIFICATIONREFERENCE($,'23-27 35 13','Variable Pitch Drives',#6409,$,$); -#6415=IFCCLASSIFICATIONREFERENCE($,'23-27 35 13 11','Pulley Variable Pitch Drives',#6414,$,$); -#6416=IFCCLASSIFICATIONREFERENCE($,'23-27 35 13 13','Traction Variable Pitch Drives',#6414,$,$); -#6417=IFCCLASSIFICATIONREFERENCE($,'23-27 35 15','Transmission Devices',#6409,$,$); -#6418=IFCCLASSIFICATIONREFERENCE($,'23-27 35 15 11','Fluid Drive Transmissions',#6417,$,$); -#6419=IFCCLASSIFICATIONREFERENCE($,'23-27 35 15 13','Gear Boxes',#6417,$,$); -#6420=IFCCLASSIFICATIONREFERENCE($,'23-27 37 00','Liquid Traps',#6107,$,$); -#6421=IFCCLASSIFICATIONREFERENCE($,'23-27 37 11','Grease Traps',#6420,$,$); -#6422=IFCCLASSIFICATIONREFERENCE($,'23-27 37 13','Oil Traps',#6420,$,$); -#6423=IFCCLASSIFICATIONREFERENCE($,'23-27 37 15','Steam Traps',#6420,$,$); -#6424=IFCCLASSIFICATIONREFERENCE($,'23-27 37 15 11','Disc Steam Traps',#6423,$,$); -#6425=IFCCLASSIFICATIONREFERENCE($,'23-27 37 15 13','Float and Thermostatic Steam Traps',#6423,$,$); -#6426=IFCCLASSIFICATIONREFERENCE($,'23-27 37 15 15','Float Steam Trap',#6423,$,$); -#6427=IFCCLASSIFICATIONREFERENCE($,'23-27 37 15 17','Inverted Basket Steam Traps',#6423,$,$); -#6428=IFCCLASSIFICATIONREFERENCE($,'23-27 37 15 19','Orifice Steam Traps',#6423,$,$); -#6429=IFCCLASSIFICATIONREFERENCE($,'23-27 39 00','Piping',#6107,$,$); -#6430=IFCCLASSIFICATIONREFERENCE($,'23-27 39 11','Double Walled Pipes',#6429,$,$); -#6431=IFCCLASSIFICATIONREFERENCE($,'23-27 39 11 11','Aboveground Double Walled Pipes',#6430,$,$); -#6432=IFCCLASSIFICATIONREFERENCE($,'23-27 39 11 13','Underground Double Walled Pipes',#6430,$,$); -#6433=IFCCLASSIFICATIONREFERENCE($,'23-27 39 13','Single Walled Pipes',#6429,$,$); -#6434=IFCCLASSIFICATIONREFERENCE($,'23-27 39 13 11','Aboveground Single Walled Pipes',#6433,$,$); -#6435=IFCCLASSIFICATIONREFERENCE($,'23-27 39 13 13','Underground Single Walled Pipes',#6433,$,$); -#6436=IFCCLASSIFICATIONREFERENCE($,'23-27 41 00','Pipe Repair Equipment',#6107,$,$); -#6437=IFCCLASSIFICATIONREFERENCE($,'23-27 41 11','Pipe Band It Kits',#6436,$,$); -#6438=IFCCLASSIFICATIONREFERENCE($,'23-27 43 00','Pipe Fittings',#6107,$,$); -#6439=IFCCLASSIFICATIONREFERENCE($,'23-27 43 11','Mechanical Pipe Fasteners',#6438,$,$); -#6440=IFCCLASSIFICATIONREFERENCE($,'23-27 43 13','Mechanical Pipe Supports',#6438,$,$); -#6441=IFCCLASSIFICATIONREFERENCE($,'23-27 43 15','Pipe Expansion Joints',#6438,$,$); -#6442=IFCCLASSIFICATIONREFERENCE($,'23-27 43 17','Water Hammer Arrestors',#6438,$,$); -#6443=IFCCLASSIFICATIONREFERENCE($,'23-27 43 19','Pipe Expansion Compensators',#6438,$,$); -#6444=IFCCLASSIFICATIONREFERENCE($,'23-27 45 00','Pipe Flanges',#6107,$,$); -#6445=IFCCLASSIFICATIONREFERENCE($,'23-27 45 11','Blind Pipe Flanges',#6444,$,$); -#6446=IFCCLASSIFICATIONREFERENCE($,'23-27 45 13','Lap Joint Pipe Flanges',#6444,$,$); -#6447=IFCCLASSIFICATIONREFERENCE($,'23-27 45 15','Orifice Pipe Flanges',#6444,$,$); -#6448=IFCCLASSIFICATIONREFERENCE($,'23-27 45 17','Plate Pipe Flanges',#6444,$,$); -#6449=IFCCLASSIFICATIONREFERENCE($,'23-27 45 19','Reducing Pipe Flanges',#6444,$,$); -#6450=IFCCLASSIFICATIONREFERENCE($,'23-27 45 21','Slip On Pipe Flanges',#6444,$,$); -#6451=IFCCLASSIFICATIONREFERENCE($,'23-27 45 23','Socket Weld Pipe Flanges',#6444,$,$); -#6452=IFCCLASSIFICATIONREFERENCE($,'23-27 45 25','Spectacle Pipe Flanges',#6444,$,$); -#6453=IFCCLASSIFICATIONREFERENCE($,'23-27 45 27','Threaded Pipe Flanges',#6444,$,$); -#6454=IFCCLASSIFICATIONREFERENCE($,'23-27 45 29','Weldneck Pipe Flanges',#6444,$,$); -#6455=IFCCLASSIFICATIONREFERENCE($,'23-27 47 00','Pipe Adapters',#6107,$,$); -#6456=IFCCLASSIFICATIONREFERENCE($,'23-27 47 11','Female Pipe Adapters',#6455,$,$); -#6457=IFCCLASSIFICATIONREFERENCE($,'23-27 47 13','Male Pipe Adapters',#6455,$,$); -#6458=IFCCLASSIFICATIONREFERENCE($,'23-27 47 15','Terminal Pipe Adapters',#6455,$,$); -#6459=IFCCLASSIFICATIONREFERENCE($,'23-27 47 17','Hi Low Converter Pipe Adapters',#6455,$,$); -#6460=IFCCLASSIFICATIONREFERENCE($,'23-27 47 19','Twist To Lock Y Cord Pipe Adapters',#6455,$,$); -#6461=IFCCLASSIFICATIONREFERENCE($,'23-27 47 21','Auto Converter Pipe Adapters',#6455,$,$); -#6462=IFCCLASSIFICATIONREFERENCE($,'23-27 47 23','Conduit Box Pipe Adapters',#6455,$,$); -#6463=IFCCLASSIFICATIONREFERENCE($,'23-27 47 25','Reduce Drive Pipe Adapters',#6455,$,$); -#6464=IFCCLASSIFICATIONREFERENCE($,'23-27 47 27','Red Pipe Adapters',#6455,$,$); -#6465=IFCCLASSIFICATIONREFERENCE($,'23-27 49 00','Pipe Couplings',#6107,$,$); -#6466=IFCCLASSIFICATIONREFERENCE($,'23-27 49 11','Rigid Pipe Couplings',#6465,$,$); -#6467=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13','Flexible Pipe Couplings',#6465,$,$); -#6468=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 11','Coil Spring Pipe Couplings',#6467,$,$); -#6469=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 13','Double Loop Pipe Couplings',#6467,$,$); -#6470=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 15','Tire Pipe Couplings',#6467,$,$); -#6471=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 17','Flexible Link Pipe Couplings',#6467,$,$); -#6472=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 19','Multi Jaw Pipe Couplings',#6467,$,$); -#6473=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 21','Helical Flex Pipe Couplings',#6467,$,$); -#6474=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 23','Magnetic Pipe Couplings',#6467,$,$); -#6475=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 25','Metal Bellows Pipe Couplings',#6467,$,$); -#6476=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 27','Diaphragm Pipe Couplings',#6467,$,$); -#6477=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 29','Roller Chain Pipe Couplings',#6467,$,$); -#6478=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 31','Schmidt Pipe Couplings',#6467,$,$); -#6479=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 33','Shear Pipe Couplings',#6467,$,$); -#6480=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 35','Sliding Block Pipe Couplings',#6467,$,$); -#6481=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 37','Steel Grid Pipe Couplings',#6467,$,$); -#6482=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 39','Spider Pipe Couplings',#6467,$,$); -#6483=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 41','Flexible Disc Pipe Couplings',#6467,$,$); -#6484=IFCCLASSIFICATIONREFERENCE($,'23-27 51 00','Pipe Elbows',#6107,$,$); -#6485=IFCCLASSIFICATIONREFERENCE($,'23-27 51 11','45 Degree Pipe Elbows',#6484,$,$); -#6486=IFCCLASSIFICATIONREFERENCE($,'23-27 51 13','90 Degree Pipe Elbows',#6484,$,$); -#6487=IFCCLASSIFICATIONREFERENCE($,'23-27 51 15','Reducing Pipe Elbows',#6484,$,$); -#6488=IFCCLASSIFICATIONREFERENCE($,'23-27 53 00','Pipe Caps',#6107,$,$); -#6489=IFCCLASSIFICATIONREFERENCE($,'23-27 53 11','Threaded Pipe Caps',#6488,$,$); -#6490=IFCCLASSIFICATIONREFERENCE($,'23-27 53 13','Tapered Pipe Caps',#6488,$,$); -#6491=IFCCLASSIFICATIONREFERENCE($,'23-27 53 15','Anti-roll Pipe Caps',#6488,$,$); -#6492=IFCCLASSIFICATIONREFERENCE($,'23-27 53 17','Knurled Pipe Caps',#6488,$,$); -#6493=IFCCLASSIFICATIONREFERENCE($,'23-27 53 19','Slotted Head Pipe Caps',#6488,$,$); -#6494=IFCCLASSIFICATIONREFERENCE($,'23-27 53 21','Retaining Ring Pipe Caps',#6488,$,$); -#6495=IFCCLASSIFICATIONREFERENCE($,'23-27 53 23','Tear Tab Pipe Caps',#6488,$,$); -#6496=IFCCLASSIFICATIONREFERENCE($,'23-27 53 25','Hanger Tip Pipe Caps',#6488,$,$); -#6497=IFCCLASSIFICATIONREFERENCE($,'23-27 53 27','Pull Tab Pipe Caps',#6488,$,$); -#6498=IFCCLASSIFICATIONREFERENCE($,'23-27 53 29','Vented Pipe Caps',#6488,$,$); -#6499=IFCCLASSIFICATIONREFERENCE($,'23-27 55 00','Liquid Treatment Components',#6107,$,$); -#6500=IFCCLASSIFICATIONREFERENCE($,'23-27 55 11','Liquid Filters',#6499,$,$); -#6501=IFCCLASSIFICATIONREFERENCE($,'23-27 55 11 11','Water Filters',#6500,$,$); -#6502=IFCCLASSIFICATIONREFERENCE($,'23-27 55 13','Liquid Sterilizers',#6499,$,$); -#6503=IFCCLASSIFICATIONREFERENCE($,'23-27 55 15','Liquid Salinators',#6499,$,$); -#6504=IFCCLASSIFICATIONREFERENCE($,'23-27 55 17','Liquid Chlorinators',#6499,$,$); -#6505=IFCCLASSIFICATIONREFERENCE($,'23-27 55 19','Liquid Ionizers',#6499,$,$); -#6506=IFCCLASSIFICATIONREFERENCE($,'23-27 55 21','Liquid Deionizers',#6499,$,$); -#6507=IFCCLASSIFICATIONREFERENCE($,'23-27 55 23','Liquid Deaerators',#6499,$,$); -#6508=IFCCLASSIFICATIONREFERENCE($,'23-27 55 23 11','Centrifugal Liquid Deaerators',#6507,$,$); -#6509=IFCCLASSIFICATIONREFERENCE($,'23-27 55 23 13','Spray Type Liquid Deaerators',#6507,$,$); -#6510=IFCCLASSIFICATIONREFERENCE($,'23-27 55 23 15','Tray Type Liquid Deaerators',#6507,$,$); -#6511=IFCCLASSIFICATIONREFERENCE($,'23-27 55 25','Liquid Disinfecting Ultraviolet Lighting',#6499,$,$); -#6512=IFCCLASSIFICATIONREFERENCE($,'23-27 55 27','Liquid Softeners',#6499,$,$); -#6513=IFCCLASSIFICATIONREFERENCE($,'23-27 55 27 11','Water Softeners',#6512,$,$); -#6514=IFCCLASSIFICATIONREFERENCE($,'23-27 55 29','Liquid Strainers',#6499,$,$); -#6515=IFCCLASSIFICATIONREFERENCE($,'23-27 55 29 11','Basket Strainers',#6514,$,$); -#6516=IFCCLASSIFICATIONREFERENCE($,'23-27 55 29 13','Conical Strainers',#6514,$,$); -#6517=IFCCLASSIFICATIONREFERENCE($,'23-27 55 29 15','Tee Strainers',#6514,$,$); -#6518=IFCCLASSIFICATIONREFERENCE($,'23-27 55 29 17','Y Strainers',#6514,$,$); -#6519=IFCCLASSIFICATIONREFERENCE($,'23-27 55 29 19','Reverse Osmosis Units',#6514,$,$); -#6520=IFCCLASSIFICATIONREFERENCE($,'23-27 55 29 21','Solid Separators',#6514,$,$); -#6521=IFCCLASSIFICATIONREFERENCE($,'23-27 55 31','Liquid Chemical Feeders',#6499,$,$); -#6522=IFCCLASSIFICATIONREFERENCE($,'23-27 55 31 11','Liquid Chemical Feeders',#6521,$,$); -#6523=IFCCLASSIFICATIONREFERENCE($,'23-27 55 31 13','Solid Chemical Feeders',#6521,$,$); -#6524=IFCCLASSIFICATIONREFERENCE($,'23-27 55 31 15','Gas Chemical Feeders',#6521,$,$); -#6525=IFCCLASSIFICATIONREFERENCE($,'23-27 55 33','Liquid Treatment Package Units',#6499,$,$); -#6526=IFCCLASSIFICATIONREFERENCE($,'23-27 55 33 11','Water Treatment Package Units',#6525,$,$); -#6527=IFCCLASSIFICATIONREFERENCE($,'23-27 55 35','Liquid Separators',#6499,$,$); -#6528=IFCCLASSIFICATIONREFERENCE($,'23-27 55 35 11','Centrifuge Liquid Separators',#6527,$,$); -#6529=IFCCLASSIFICATIONREFERENCE($,'23-27 55 35 13','Demister Pad Liquid Separators',#6527,$,$); -#6530=IFCCLASSIFICATIONREFERENCE($,'23-27 55 35 15','Electrical Cyclone Liquid Separators',#6527,$,$); -#6531=IFCCLASSIFICATIONREFERENCE($,'23-27 55 35 17','Hydro Cyclone Liquid Separators',#6527,$,$); -#6532=IFCCLASSIFICATIONREFERENCE($,'23-27 55 35 19','Mechanical Liquid Separators',#6527,$,$); -#6533=IFCCLASSIFICATIONREFERENCE($,'23-27 55 35 21','Mist Eliminator Liquid Separators',#6527,$,$); -#6534=IFCCLASSIFICATIONREFERENCE($,'23-27 55 35 23','Tangential Liquid Separators',#6527,$,$); -#6535=IFCCLASSIFICATIONREFERENCE($,'23-27 55 35 25','Magnetic Electronic Water Treatment',#6527,$,$); -#6536=IFCCLASSIFICATIONREFERENCE($,'23-27 55 35 27','Oil Water Curtain Separators',#6527,$,$); -#6537=IFCCLASSIFICATIONREFERENCE($,'23-27 57 00','Gas Treatment Components',#6107,$,$); -#6538=IFCCLASSIFICATIONREFERENCE($,'23-27 57 11','Vapor Traps',#6537,$,$); -#6539=IFCCLASSIFICATIONREFERENCE($,'23-27 57 13','Extractors',#6537,$,$); -#6540=IFCCLASSIFICATIONREFERENCE($,'23-27 57 13 11','Extractors for Process Air',#6539,$,$); -#6541=IFCCLASSIFICATIONREFERENCE($,'23-27 57 15','Air Injectors',#6537,$,$); -#6542=IFCCLASSIFICATIONREFERENCE($,'23-27 57 17','Air Ejectors',#6537,$,$); -#6543=IFCCLASSIFICATIONREFERENCE($,'23-27 57 19','Air Scrubbers',#6537,$,$); -#6544=IFCCLASSIFICATIONREFERENCE($,'23-27 57 19 11','Dual Throat Air Scrubbers',#6543,$,$); -#6545=IFCCLASSIFICATIONREFERENCE($,'23-27 57 19 13','Multiple Venture Air Scrubbers',#6543,$,$); -#6546=IFCCLASSIFICATIONREFERENCE($,'23-27 57 19 15','Packed Bed Air Scrubbers',#6543,$,$); -#6547=IFCCLASSIFICATIONREFERENCE($,'23-27 57 21','Supply Gas Treatment',#6537,$,$); -#6548=IFCCLASSIFICATIONREFERENCE($,'23-27 57 21 11','Steam Treatment',#6547,$,$); -#6549=IFCCLASSIFICATIONREFERENCE($,'23-27 57 21 13','Fuel Gas Treatment',#6547,$,$); -#6550=IFCCLASSIFICATIONREFERENCE($,'23-27 57 21 13 11','Gas Filters',#6549,$,$); -#6551=IFCCLASSIFICATIONREFERENCE($,'23-27 57 23','Electronic Air Purifiers',#6537,$,$); -#6552=IFCCLASSIFICATIONREFERENCE($,'23-27 57 25','Mechanically Aided Air Scrubbers',#6537,$,$); -#6553=IFCCLASSIFICATIONREFERENCE($,'23-27 57 27','Air Filters',#6537,$,$); -#6554=IFCCLASSIFICATIONREFERENCE($,'23-27 57 27 11','Air Filter Components',#6553,$,$); -#6555=IFCCLASSIFICATIONREFERENCE($,'23-27 57 27 11 11','Air Filter Media',#6554,$,$); -#6556=IFCCLASSIFICATIONREFERENCE($,'23-27 57 27 11 13','Control Air Filter Assemblies',#6554,$,$); -#6557=IFCCLASSIFICATIONREFERENCE($,'23-27 57 27 13','High Efficiency Air Filters',#6553,$,$); -#6558=IFCCLASSIFICATIONREFERENCE($,'23-27 57 27 15','ULPA Filters',#6553,$,$); -#6559=IFCCLASSIFICATIONREFERENCE($,'23-27 57 27 17','HEPA Filters',#6553,$,$); -#6560=IFCCLASSIFICATIONREFERENCE($,'23-27 57 27 19','Bag Filters',#6553,$,$); -#6561=IFCCLASSIFICATIONREFERENCE($,'23-27 57 27 21','Air Filter Housings',#6553,$,$); -#6562=IFCCLASSIFICATIONREFERENCE($,'23-27 57 27 23','Air Charcoal Filters',#6553,$,$); -#6563=IFCCLASSIFICATIONREFERENCE($,'23-27 57 27 25','Roll Type Filters',#6553,$,$); -#6564=IFCCLASSIFICATIONREFERENCE($,'23-27 57 29','Dust Collectors',#6537,$,$); -#6565=IFCCLASSIFICATIONREFERENCE($,'23-27 57 31','Electronic Air Cleaners',#6537,$,$); -#6566=IFCCLASSIFICATIONREFERENCE($,'23-27 57 33','Air Fresheners',#6537,$,$); -#6567=IFCCLASSIFICATIONREFERENCE($,'23-27 57 35','Air Treatment Components',#6537,$,$); -#6568=IFCCLASSIFICATIONREFERENCE($,'23-27 57 35 11','Air Deodorization Products',#6567,$,$); -#6569=IFCCLASSIFICATIONREFERENCE($,'23-27 57 35 13','Moisture Absorbents',#6567,$,$); -#6570=IFCCLASSIFICATIONREFERENCE($,'23-27 59 00','Recycling Equipment',#6107,$,$); -#6571=IFCCLASSIFICATIONREFERENCE($,'23-27 59 11','Recycling Balers',#6570,$,$); -#6572=IFCCLASSIFICATIONREFERENCE($,'23-27 59 11 11','Recycling Cardboard Balers',#6571,$,$); -#6573=IFCCLASSIFICATIONREFERENCE($,'23-27 59 11 13','Recycling Paper Balers',#6571,$,$); -#6574=IFCCLASSIFICATIONREFERENCE($,'23-27 59 11 15','Recycling Plastic Balers',#6571,$,$); -#6575=IFCCLASSIFICATIONREFERENCE($,'23-27 59 11 17','Recycling Wood Balers',#6571,$,$); -#6576=IFCCLASSIFICATIONREFERENCE($,'23-27 59 13','Recycling Bins',#6570,$,$); -#6577=IFCCLASSIFICATIONREFERENCE($,'23-27 59 15','Recycling Compactors',#6570,$,$); -#6578=IFCCLASSIFICATIONREFERENCE($,'23-27 59 15 11','Cardboard Compactors',#6577,$,$); -#6579=IFCCLASSIFICATIONREFERENCE($,'23-27 59 15 13','Metal Compactors',#6577,$,$); -#6580=IFCCLASSIFICATIONREFERENCE($,'23-27 59 15 15','Paper Compactors',#6577,$,$); -#6581=IFCCLASSIFICATIONREFERENCE($,'23-27 59 15 17','Plastic Compactors',#6577,$,$); -#6582=IFCCLASSIFICATIONREFERENCE($,'23-27 59 15 19','Trash Compactors',#6577,$,$); -#6583=IFCCLASSIFICATIONREFERENCE($,'23-27 59 15 21','Wood Compactors',#6577,$,$); -#6584=IFCCLASSIFICATIONREFERENCE($,'23-27 61 00','Incinerators',#6107,$,$); -#6585=IFCCLASSIFICATIONREFERENCE($,'23-27 61 11','Trash Incinerators',#6584,$,$); -#6586=IFCCLASSIFICATIONREFERENCE($,'23-27 61 13','Document Incinerators',#6584,$,$); -#6587=IFCCLASSIFICATIONREFERENCE($,'23-27 63 00','Mechanical Insulation and Linings',#6107,$,$); -#6588=IFCCLASSIFICATIONREFERENCE($,'23-27 63 11','Pipe Insulation',#6587,$,$); -#6589=IFCCLASSIFICATIONREFERENCE($,'23-27 63 13','Equipment Insulation Blankets',#6587,$,$); -#6590=IFCCLASSIFICATIONREFERENCE($,'23-27 65 00','Equipment Acoustic Insulation',#6107,$,$); -#6591=IFCCLASSIFICATIONREFERENCE($,'23-27 65 11','Sound Dampening Equipment Mounts',#6590,$,$); -#6592=IFCCLASSIFICATIONREFERENCE($,'23-27 67 00','Corrosion Proofing Equipment',#6107,$,$); -#6593=IFCCLASSIFICATIONREFERENCE($,'23-27 67 11','Zinc Bars',#6592,$,$); -#6594=IFCCLASSIFICATIONREFERENCE($,'23-27 67 13','Zinc Tapes',#6592,$,$); -#6595=IFCCLASSIFICATIONREFERENCE($,'23-27 69 00','Antivibration Mountings',#6107,$,$); -#6596=IFCCLASSIFICATIONREFERENCE($,'23-27 69 11','Vibration Equipment Mounts',#6595,$,$); -#6597=IFCCLASSIFICATIONREFERENCE($,'23-27 71 00','Building Maintenance Equipment',#6107,$,$); -#6598=IFCCLASSIFICATIONREFERENCE($,'23-27 71 11','Window Washing Systems',#6597,$,$); -#6599=IFCCLASSIFICATIONREFERENCE($,'23-27 71 13','Building Maintenance Cradles and Platforms',#6597,$,$); -#6600=IFCCLASSIFICATIONREFERENCE($,'23-27 71 15','Roof Trolley Systems',#6597,$,$); -#6601=IFCCLASSIFICATIONREFERENCE($,'23-27 71 17','Traveling Ladder Systems',#6597,$,$); -#6602=IFCCLASSIFICATIONREFERENCE($,'23-27 71 19','Ancillary Building Maintenance Items',#6597,$,$); -#6603=IFCCLASSIFICATIONREFERENCE($,'23-27 71 19 11','Building Safety Tracks',#6602,$,$); -#6604=IFCCLASSIFICATIONREFERENCE($,'23-27 71 19 13','Anchors for Building Maintenance',#6602,$,$); -#6605=IFCCLASSIFICATIONREFERENCE($,'23-27 71 21','Fall Arrest Systems',#6597,$,$); -#6606=IFCCLASSIFICATIONREFERENCE($,'23-29 00 00','Facility and Occupant Protection Products',#1604,$,$); -#6607=IFCCLASSIFICATIONREFERENCE($,'23-29 11 00','Security Detection and Monitoring',#6606,$,$); -#6608=IFCCLASSIFICATIONREFERENCE($,'23-29 11 11','Closed Circuit Television Equipment',#6607,$,$); -#6609=IFCCLASSIFICATIONREFERENCE($,'23-29 11 11 11','Infra Red CCTV Cameras',#6608,$,$); -#6610=IFCCLASSIFICATIONREFERENCE($,'23-29 11 11 13','Visual Light Wavelength CCTV Cameras',#6608,$,$); -#6611=IFCCLASSIFICATIONREFERENCE($,'23-29 11 11 15','CCTV Camera Enclosures',#6608,$,$); -#6612=IFCCLASSIFICATIONREFERENCE($,'23-29 11 11 17','Security Camera Controllers',#6608,$,$); -#6613=IFCCLASSIFICATIONREFERENCE($,'23-29 11 11 19','Security Camera Multiplexors',#6608,$,$); -#6614=IFCCLASSIFICATIONREFERENCE($,'23-29 11 11 21','Security Camera Monitoring System Panels',#6608,$,$); -#6615=IFCCLASSIFICATIONREFERENCE($,'23-29 11 13','Security Video Imaging System Equipment',#6607,$,$); -#6616=IFCCLASSIFICATIONREFERENCE($,'23-29 11 13 11','Security Video Monitors',#6615,$,$); -#6617=IFCCLASSIFICATIONREFERENCE($,'23-29 11 13 13','Security Video Recorders',#6615,$,$); -#6618=IFCCLASSIFICATIONREFERENCE($,'23-29 11 13 13 11','Security Analog Video Recorders',#6617,$,$); -#6619=IFCCLASSIFICATIONREFERENCE($,'23-29 11 13 13 13','Security Digital Video Recorders',#6617,$,$); -#6620=IFCCLASSIFICATIONREFERENCE($,'23-29 11 15','Explosive Detectors',#6607,$,$); -#6621=IFCCLASSIFICATIONREFERENCE($,'23-29 11 15 11','Explosive Detector Sniffers',#6620,$,$); -#6622=IFCCLASSIFICATIONREFERENCE($,'23-29 11 15 11 11','Chemical Explosive Detectors',#6621,$,$); -#6623=IFCCLASSIFICATIONREFERENCE($,'23-29 11 15 11 13','Particulate Explosive Detectors',#6621,$,$); -#6624=IFCCLASSIFICATIONREFERENCE($,'23-29 11 15 13','Explosive Detector Spectral Analyzers',#6620,$,$); -#6625=IFCCLASSIFICATIONREFERENCE($,'23-29 11 17','Security Metal Detectors',#6607,$,$); -#6626=IFCCLASSIFICATIONREFERENCE($,'23-29 11 17 11','Security Weather Resistant Walk Through Metal Detectors',#6625,$,$); -#6627=IFCCLASSIFICATIONREFERENCE($,'23-29 11 17 13','Security Indoor Walk Through Metal Detectors',#6625,$,$); -#6628=IFCCLASSIFICATIONREFERENCE($,'23-29 11 17 15','Security Hand Held Metal Detectors',#6625,$,$); -#6629=IFCCLASSIFICATIONREFERENCE($,'23-29 11 19','Security X Ray Machines',#6607,$,$); -#6630=IFCCLASSIFICATIONREFERENCE($,'23-29 11 19 11','Security X Ray Conveyor Machines',#6629,$,$); -#6631=IFCCLASSIFICATIONREFERENCE($,'23-29 11 19 13','Security Personnel X Ray Machines',#6629,$,$); -#6632=IFCCLASSIFICATIONREFERENCE($,'23-29 11 21','Security Sensors',#6607,$,$); -#6633=IFCCLASSIFICATIONREFERENCE($,'23-29 11 21 11','Audio Security Sensors',#6632,$,$); -#6634=IFCCLASSIFICATIONREFERENCE($,'23-29 11 21 13','Security Ground Loop Sensors',#6632,$,$); -#6635=IFCCLASSIFICATIONREFERENCE($,'23-29 11 21 15','Infra Red Security Sensors',#6632,$,$); -#6636=IFCCLASSIFICATIONREFERENCE($,'23-29 11 21 17','Ultrasonic Security Sensors',#6632,$,$); -#6637=IFCCLASSIFICATIONREFERENCE($,'23-29 11 21 19','Security Vibration Sensors',#6632,$,$); -#6638=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23','Intrusion Detection Devices',#6607,$,$); -#6639=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23 11','Intrusion Detection Buried Cables',#6638,$,$); -#6640=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23 13','Intrusion Detection Fiber Optic Fence Line Loops',#6638,$,$); -#6641=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23 15','Intrusion Detection Microwave Alarms',#6638,$,$); -#6642=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23 17','Intrusion Detection Photoelectric Sensors',#6638,$,$); -#6643=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23 19','Intrusion Detection Door Monitoring Switches',#6638,$,$); -#6644=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23 21','Pressure Mats',#6638,$,$); -#6645=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23 23','Door Micro Switch Contacts',#6638,$,$); -#6646=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23 25','Window Micro Switch Contacts',#6638,$,$); -#6647=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23 27','Break Glass Detection',#6638,$,$); -#6648=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23 29','Movement Vibration Detection',#6638,$,$); -#6649=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23 31','Infra Red Radiation Personnel Detectors',#6638,$,$); -#6650=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23 33','Microwave Personnel Detectors',#6638,$,$); -#6651=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23 35','Security Autodialers',#6638,$,$); -#6652=IFCCLASSIFICATIONREFERENCE($,'23-29 11 25','Presence Detection Registration',#6607,$,$); -#6653=IFCCLASSIFICATIONREFERENCE($,'23-29 11 25 11','Personnel Clocking In and Recording Equipment',#6652,$,$); -#6654=IFCCLASSIFICATIONREFERENCE($,'23-29 11 25 13','Surveillance Mirrors',#6652,$,$); -#6655=IFCCLASSIFICATIONREFERENCE($,'23-29 11 25 15','Manual Alert Control',#6652,$,$); -#6656=IFCCLASSIFICATIONREFERENCE($,'23-29 11 25 17','Security Door Bells',#6652,$,$); -#6657=IFCCLASSIFICATIONREFERENCE($,'23-29 11 25 19','Security Buzzers',#6652,$,$); -#6658=IFCCLASSIFICATIONREFERENCE($,'23-29 11 27','Security Keypads',#6607,$,$); -#6659=IFCCLASSIFICATIONREFERENCE($,'23-29 11 27 11','Alarm Keypads',#6658,$,$); -#6660=IFCCLASSIFICATIONREFERENCE($,'23-29 11 27 13','Security Keypads',#6658,$,$); -#6661=IFCCLASSIFICATIONREFERENCE($,'23-29 11 29','Vehicle Inspection Devices',#6607,$,$); -#6662=IFCCLASSIFICATIONREFERENCE($,'23-29 11 29 11','Undercarriage Inspection Lighting',#6661,$,$); -#6663=IFCCLASSIFICATIONREFERENCE($,'23-29 13 00','Security Access Controls',#6606,$,$); -#6664=IFCCLASSIFICATIONREFERENCE($,'23-29 13 11','Personnel Biometric Readers',#6663,$,$); -#6665=IFCCLASSIFICATIONREFERENCE($,'23-29 13 11 11','Fingerprint Readers',#6664,$,$); -#6666=IFCCLASSIFICATIONREFERENCE($,'23-29 13 11 13','Hand Geometry Readers',#6664,$,$); -#6667=IFCCLASSIFICATIONREFERENCE($,'23-29 13 11 15','Iris Scanners',#6664,$,$); -#6668=IFCCLASSIFICATIONREFERENCE($,'23-29 13 11 17','Retinal Scanners',#6664,$,$); -#6669=IFCCLASSIFICATIONREFERENCE($,'23-29 13 11 19','Vein Recognition Readers',#6664,$,$); -#6670=IFCCLASSIFICATIONREFERENCE($,'23-29 13 13','Personnel Card Readers',#6663,$,$); -#6671=IFCCLASSIFICATIONREFERENCE($,'23-29 13 13 11','Personnel Contact Card Readers',#6670,$,$); -#6672=IFCCLASSIFICATIONREFERENCE($,'23-29 13 13 11 11','Mag Stripe Personnel Contact Card Readers',#6671,$,$); -#6673=IFCCLASSIFICATIONREFERENCE($,'23-29 13 13 11 13','Smart Card Personnel Contact Card Readers',#6671,$,$); -#6674=IFCCLASSIFICATIONREFERENCE($,'23-29 13 13 11 15','Weigand Personnel Contact Card Readers',#6671,$,$); -#6675=IFCCLASSIFICATIONREFERENCE($,'23-29 13 13 13','Personnel Contactless Card Readers',#6670,$,$); -#6676=IFCCLASSIFICATIONREFERENCE($,'23-29 13 13 13 11','Barcode Personnel Contactless Card Readers',#6675,$,$); -#6677=IFCCLASSIFICATIONREFERENCE($,'23-29 13 13 13 13','Near Field Proximity Personnel Contactless Card Readers',#6675,$,$); -#6678=IFCCLASSIFICATIONREFERENCE($,'23-29 13 13 13 15','Proximity Personnel Contactless Card Readers',#6675,$,$); -#6679=IFCCLASSIFICATIONREFERENCE($,'23-29 13 15','Personnel Counting Equipment',#6663,$,$); -#6680=IFCCLASSIFICATIONREFERENCE($,'23-29 13 17','Security Door Answering Controls',#6663,$,$); -#6681=IFCCLASSIFICATIONREFERENCE($,'23-29 13 19','Electronic Key Equipment',#6663,$,$); -#6682=IFCCLASSIFICATIONREFERENCE($,'23-29 13 21','Security Personnel Access Keypads',#6663,$,$); -#6683=IFCCLASSIFICATIONREFERENCE($,'23-29 13 23','Access Control Turnstiles',#6663,$,$); -#6684=IFCCLASSIFICATIONREFERENCE($,'23-29 13 23 11','Waist Height Turnstiles',#6683,$,$); -#6685=IFCCLASSIFICATIONREFERENCE($,'23-29 13 23 13','Full Height Turnstiles',#6683,$,$); -#6686=IFCCLASSIFICATIONREFERENCE($,'23-29 13 23 15','Portable Post and Railing Barriers',#6683,$,$); -#6687=IFCCLASSIFICATIONREFERENCE($,'23-29 15 00','Secure Storage Structures and Products',#6606,$,$); -#6688=IFCCLASSIFICATIONREFERENCE($,'23-29 15 11','Vaults',#6687,$,$); -#6689=IFCCLASSIFICATIONREFERENCE($,'23-29 15 11 11','Prefabricated Room Vaults',#6688,$,$); -#6690=IFCCLASSIFICATIONREFERENCE($,'23-29 15 11 13','Commercial Vaults',#6688,$,$); -#6691=IFCCLASSIFICATIONREFERENCE($,'23-29 15 11 15','Residential Vaults',#6688,$,$); -#6692=IFCCLASSIFICATIONREFERENCE($,'23-29 15 13','Safes',#6687,$,$); -#6693=IFCCLASSIFICATIONREFERENCE($,'23-29 15 13 11','Commercial Safes',#6692,$,$); -#6694=IFCCLASSIFICATIONREFERENCE($,'23-29 15 13 13','Residential Safes',#6692,$,$); -#6695=IFCCLASSIFICATIONREFERENCE($,'23-29 15 15','Lockers',#6687,$,$); -#6696=IFCCLASSIFICATIONREFERENCE($,'23-29 15 15 11','Metal Lockers',#6695,$,$); -#6697=IFCCLASSIFICATIONREFERENCE($,'23-29 15 15 13','Wood Lockers',#6695,$,$); -#6698=IFCCLASSIFICATIONREFERENCE($,'23-29 15 15 15','Plastic Laminate Clad Lockers',#6695,$,$); -#6699=IFCCLASSIFICATIONREFERENCE($,'23-29 15 15 17','Plastic Lockers',#6695,$,$); -#6700=IFCCLASSIFICATIONREFERENCE($,'23-29 15 15 19','Glass Lockers',#6695,$,$); -#6701=IFCCLASSIFICATIONREFERENCE($,'23-29 15 15 21','Wire Mesh Storage Lockers',#6695,$,$); -#6702=IFCCLASSIFICATIONREFERENCE($,'23-29 17 00','Property Storage Locks',#6606,$,$); -#6703=IFCCLASSIFICATIONREFERENCE($,'23-29 17 11','Bicycle Locks',#6702,$,$); -#6704=IFCCLASSIFICATIONREFERENCE($,'23-29 17 13','Padlocks',#6702,$,$); -#6705=IFCCLASSIFICATIONREFERENCE($,'23-29 17 13 11','Combination Padlocks',#6704,$,$); -#6706=IFCCLASSIFICATIONREFERENCE($,'23-29 17 13 13','Pin Tumbler Padlocks',#6704,$,$); -#6707=IFCCLASSIFICATIONREFERENCE($,'23-29 19 00','Chemical Biological Radiological Protection',#6606,$,$); -#6708=IFCCLASSIFICATIONREFERENCE($,'23-29 19 11','Prefabricated Mail Screening Products',#6707,$,$); -#6709=IFCCLASSIFICATIONREFERENCE($,'23-29 19 13','Biological Safety Cabinets',#6707,$,$); -#6710=IFCCLASSIFICATIONREFERENCE($,'23-29 21 00','Equipment for Security of Information',#6606,$,$); -#6711=IFCCLASSIFICATIONREFERENCE($,'23-29 21 11','Centralized Code Reading Equipment',#6710,$,$); -#6712=IFCCLASSIFICATIONREFERENCE($,'23-29 23 00','Fireproofing Components',#6606,$,$); -#6713=IFCCLASSIFICATIONREFERENCE($,'23-29 23 11','Fireproofing Gaskets',#6712,$,$); -#6714=IFCCLASSIFICATIONREFERENCE($,'23-29 23 13','Fireproofing Fillers for Threaded Couplings',#6712,$,$); -#6715=IFCCLASSIFICATIONREFERENCE($,'23-29 23 15','Fireproof Pipe Sleeves',#6712,$,$); -#6716=IFCCLASSIFICATIONREFERENCE($,'23-29 23 17','Smoke Seals for Ductwork',#6712,$,$); -#6717=IFCCLASSIFICATIONREFERENCE($,'23-29 25 00','Fire Fighting Equipment',#6606,$,$); -#6718=IFCCLASSIFICATIONREFERENCE($,'23-29 25 11','Fire Fighting Terminals',#6717,$,$); -#6719=IFCCLASSIFICATIONREFERENCE($,'23-29 25 11 11','Fire Fighting Terminal Components',#6718,$,$); -#6720=IFCCLASSIFICATIONREFERENCE($,'23-29 25 11 13','Water Fire Fighting Terminals',#6718,$,$); -#6721=IFCCLASSIFICATIONREFERENCE($,'23-29 25 11 15','Gaseous Fire Fighting Terminals',#6718,$,$); -#6722=IFCCLASSIFICATIONREFERENCE($,'23-29 25 11 17','Foam Fire Fighting Terminals',#6718,$,$); -#6723=IFCCLASSIFICATIONREFERENCE($,'23-29 25 11 19','Powder Fire Fighting Terminals',#6718,$,$); -#6724=IFCCLASSIFICATIONREFERENCE($,'23-29 25 11 21','Fire Fighting Media',#6718,$,$); -#6725=IFCCLASSIFICATIONREFERENCE($,'23-29 25 11 23','Fire Fighting Gas Terminals',#6718,$,$); -#6726=IFCCLASSIFICATIONREFERENCE($,'23-29 25 13','Fire Hydrants',#6717,$,$); -#6727=IFCCLASSIFICATIONREFERENCE($,'23-29 25 13 11','Dry Barrel Fire Hydrants',#6726,$,$); -#6728=IFCCLASSIFICATIONREFERENCE($,'23-29 25 13 13','Wet Barrel Fire Hydrants',#6726,$,$); -#6729=IFCCLASSIFICATIONREFERENCE($,'23-29 25 15','Fire Hose Equipment',#6717,$,$); -#6730=IFCCLASSIFICATIONREFERENCE($,'23-29 25 15 11','Fire Hoses',#6729,$,$); -#6731=IFCCLASSIFICATIONREFERENCE($,'23-29 25 15 13','Fire Hose Outlets',#6729,$,$); -#6732=IFCCLASSIFICATIONREFERENCE($,'23-29 25 15 15','Cabinets for Fire Hoses',#6729,$,$); -#6733=IFCCLASSIFICATIONREFERENCE($,'23-29 25 15 17','Fire Hose Reels',#6729,$,$); -#6734=IFCCLASSIFICATIONREFERENCE($,'23-29 25 15 19','Fire Hose Connectors',#6729,$,$); -#6735=IFCCLASSIFICATIONREFERENCE($,'23-29 25 15 19 11','Fire Fighting Standpipes',#6734,$,$); -#6736=IFCCLASSIFICATIONREFERENCE($,'23-29 25 15 19 13','Fire Fighting Pumper Connections',#6734,$,$); -#6737=IFCCLASSIFICATIONREFERENCE($,'23-29 25 17','Fire Nozzles',#6717,$,$); -#6738=IFCCLASSIFICATIONREFERENCE($,'23-29 25 17 11','Fire Fog Nozzles',#6737,$,$); -#6739=IFCCLASSIFICATIONREFERENCE($,'23-29 25 17 13','Fire Stream Nozzles',#6737,$,$); -#6740=IFCCLASSIFICATIONREFERENCE($,'23-29 25 17 15','Fire Electrical Rated Nozzles',#6737,$,$); -#6741=IFCCLASSIFICATIONREFERENCE($,'23-29 25 19','Fire Extinguishers',#6717,$,$); -#6742=IFCCLASSIFICATIONREFERENCE($,'23-29 25 19 11','Stored Pressure Fire Extinguishers',#6741,$,$); -#6743=IFCCLASSIFICATIONREFERENCE($,'23-29 25 19 11 11','Stored Pressure Fire Extinguishers With Gauge',#6742,$,$); -#6744=IFCCLASSIFICATIONREFERENCE($,'23-29 25 19 13','Non Stainless Steel Fire Extinguishers',#6741,$,$); -#6745=IFCCLASSIFICATIONREFERENCE($,'23-29 25 19 15','Non Rechargeable Fire Extinguishers',#6741,$,$); -#6746=IFCCLASSIFICATIONREFERENCE($,'23-29 25 19 17','Gas Cart Fire Extinguishers',#6741,$,$); -#6747=IFCCLASSIFICATIONREFERENCE($,'23-29 25 19 17 11','Gas Cart Fire Extinguishers With Gauge',#6746,$,$); -#6748=IFCCLASSIFICATIONREFERENCE($,'23-29 25 19 19','Foam Fire Extinguishers',#6741,$,$); -#6749=IFCCLASSIFICATIONREFERENCE($,'23-29 27 00','Fire Ventilation Equipment',#6606,$,$); -#6750=IFCCLASSIFICATIONREFERENCE($,'23-29 27 11','Fire Fighting Smoke Extractors',#6749,$,$); -#6751=IFCCLASSIFICATIONREFERENCE($,'23-29 29 00','Fire Detection Devices',#6606,$,$); -#6752=IFCCLASSIFICATIONREFERENCE($,'23-29 29 11','Fire Alarm Pull Stations',#6751,$,$); -#6753=IFCCLASSIFICATIONREFERENCE($,'23-29 29 11 11','Addressable Fire Alarm Pull Stations',#6752,$,$); -#6754=IFCCLASSIFICATIONREFERENCE($,'23-29 29 11 13','Non Addressable Fire Alarm Pull Stations',#6752,$,$); -#6755=IFCCLASSIFICATIONREFERENCE($,'23-29 29 13','Fire Detectors',#6751,$,$); -#6756=IFCCLASSIFICATIONREFERENCE($,'23-29 29 13 11','Smoke Detectors',#6755,$,$); -#6757=IFCCLASSIFICATIONREFERENCE($,'23-29 29 13 11 11','Spot Type Photoelectric Smoke Detectors',#6756,$,$); -#6758=IFCCLASSIFICATIONREFERENCE($,'23-29 29 13 11 13','Spot Type Ionization Smoke Detectors',#6756,$,$); -#6759=IFCCLASSIFICATIONREFERENCE($,'23-29 29 13 11 15','Spot Type Duct Photoelectric Smoke Detectors',#6756,$,$); -#6760=IFCCLASSIFICATIONREFERENCE($,'23-29 29 13 11 17','Spot Type Duct Ionization Smoke Detectors',#6756,$,$); -#6761=IFCCLASSIFICATIONREFERENCE($,'23-29 29 13 11 19','Beam Type Smoke Detectors',#6756,$,$); -#6762=IFCCLASSIFICATIONREFERENCE($,'23-29 29 13 13','Heat Detectors',#6755,$,$); -#6763=IFCCLASSIFICATIONREFERENCE($,'23-29 29 13 13 11','Fixed Temperature Heat Detectors',#6762,$,$); -#6764=IFCCLASSIFICATIONREFERENCE($,'23-29 29 13 13 13','Rate of Rise Heat Detectors',#6762,$,$); -#6765=IFCCLASSIFICATIONREFERENCE($,'23-29 29 13 15','Flame Detectors',#6755,$,$); -#6766=IFCCLASSIFICATIONREFERENCE($,'23-29 29 13 17','Spark and Ember Detectors',#6755,$,$); -#6767=IFCCLASSIFICATIONREFERENCE($,'23-29 29 13 19','Radiant Energy Detectors',#6755,$,$); -#6768=IFCCLASSIFICATIONREFERENCE($,'23-29 29 15','Fire Switches',#6751,$,$); -#6769=IFCCLASSIFICATIONREFERENCE($,'23-29 29 15 11','Pressure Fire Alarm Water Flow Switches',#6768,$,$); -#6770=IFCCLASSIFICATIONREFERENCE($,'23-29 29 15 13','Paddle Fire Alarm Water Flow Switches',#6768,$,$); -#6771=IFCCLASSIFICATIONREFERENCE($,'23-29 29 15 15','Fire Tamper Switches',#6768,$,$); -#6772=IFCCLASSIFICATIONREFERENCE($,'23-29 31 00','Fire Notification Appliances',#6606,$,$); -#6773=IFCCLASSIFICATIONREFERENCE($,'23-29 31 11','Fire Alarm Annunicator Panels',#6772,$,$); -#6774=IFCCLASSIFICATIONREFERENCE($,'23-29 31 11 11','Audible Fire Alarm Annunicator Panels',#6773,$,$); -#6775=IFCCLASSIFICATIONREFERENCE($,'23-29 31 11 13','Visible Fire Alarm Annunicator Panels',#6773,$,$); -#6776=IFCCLASSIFICATIONREFERENCE($,'23-29 31 11 15','Combination Fire Alarm Annunicator Panels',#6773,$,$); -#6777=IFCCLASSIFICATIONREFERENCE($,'23-29 31 13','Fire Alarm Control Panels',#6772,$,$); -#6778=IFCCLASSIFICATIONREFERENCE($,'23-29 31 13 11','Main Fire Alarm Control Panels',#6777,$,$); -#6779=IFCCLASSIFICATIONREFERENCE($,'23-29 31 13 13','Secondary Fire Alarm Control Panels',#6777,$,$); -#6780=IFCCLASSIFICATIONREFERENCE($,'23-29 31 13 15','Fire Alarm Audio Control Panels',#6777,$,$); -#6781=IFCCLASSIFICATIONREFERENCE($,'23-29 31 13 17','Fire Alarm Smoke Control Panels',#6777,$,$); -#6782=IFCCLASSIFICATIONREFERENCE($,'23-29 31 15','Audible Fire Notification Devices',#6772,$,$); -#6783=IFCCLASSIFICATIONREFERENCE($,'23-29 31 15 11','Audible Fire Notification Devices Bell',#6782,$,$); -#6784=IFCCLASSIFICATIONREFERENCE($,'23-29 31 15 13','Audible Fire Notification Devices Horn',#6782,$,$); -#6785=IFCCLASSIFICATIONREFERENCE($,'23-29 31 15 15','Audible Fire Notification Devices Chime',#6782,$,$); -#6786=IFCCLASSIFICATIONREFERENCE($,'23-29 31 15 17','Audible Fire Notification Devices Speaker',#6782,$,$); -#6787=IFCCLASSIFICATIONREFERENCE($,'23-29 31 17','Visible Fire Notification Devices',#6772,$,$); -#6788=IFCCLASSIFICATIONREFERENCE($,'23-29 31 17 11','Visible Fire Notification Device Lights',#6787,$,$); -#6789=IFCCLASSIFICATIONREFERENCE($,'23-29 31 19','Combination Audible and Visible Fire Notification Devices',#6772,$,$); -#6790=IFCCLASSIFICATIONREFERENCE($,'23-29 31 21','Fire Alarm Communicators',#6772,$,$); -#6791=IFCCLASSIFICATIONREFERENCE($,'23-29 31 23','Fire Alarm Central Stations',#6772,$,$); -#6792=IFCCLASSIFICATIONREFERENCE($,'23-29 31 23 11','Fire Alarm Central Station Transmitters',#6791,$,$); -#6793=IFCCLASSIFICATIONREFERENCE($,'23-29 31 23 13','Fire Alarm Central Station Receivers',#6791,$,$); -#6794=IFCCLASSIFICATIONREFERENCE($,'23-29 31 23 15','Fire Alarm Central Station Combination Transmitter and Receivers',#6791,$,$); -#6795=IFCCLASSIFICATIONREFERENCE($,'23-29 31 25','Fire Alarm Event Recorders',#6772,$,$); -#6796=IFCCLASSIFICATIONREFERENCE($,'23-29 31 27','Fire Alarm Event Printers',#6772,$,$); -#6797=IFCCLASSIFICATIONREFERENCE($,'23-29 31 29','Fire Alarm Remote Controllers',#6772,$,$); -#6798=IFCCLASSIFICATIONREFERENCE($,'23-29 31 31','Fire Alarm Remote Amplifiers',#6772,$,$); -#6799=IFCCLASSIFICATIONREFERENCE($,'23-29 31 33','Fire Pump Controllers',#6772,$,$); -#6800=IFCCLASSIFICATIONREFERENCE($,'23-29 31 35','Jockey Pump Controllers',#6772,$,$); -#6801=IFCCLASSIFICATIONREFERENCE($,'23-29 33 00','Fire Suppression System Components',#6606,$,$); -#6802=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11','Water Based Suppression Equipment',#6801,$,$); -#6803=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11 11','Pendant Sprinkler Heads',#6802,$,$); -#6804=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11 11 11','Wet Pendant Sprinkler Heads',#6803,$,$); -#6805=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11 11 13','Dry Pendant Sprinkler Heads',#6803,$,$); -#6806=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11 11 15','Open Pendant Sprinkler Heads',#6803,$,$); -#6807=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11 13','Upright Sprinkler Heads',#6802,$,$); -#6808=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11 13 11','Wet Upright Sprinkler Heads',#6807,$,$); -#6809=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11 13 13','Dry Upright Sprinkler Heads',#6807,$,$); -#6810=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11 13 15','Open Upright Sprinkler Heads',#6807,$,$); -#6811=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11 15','Side Wall Sprinkler Heads',#6802,$,$); -#6812=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11 15 11','Wet Side Wall Sprinkler Heads',#6811,$,$); -#6813=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11 15 13','Dry Side Wall Sprinkler Heads',#6811,$,$); -#6814=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11 17','Dry Pipe Valves',#6802,$,$); -#6815=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11 19','Water Mist Systems',#6802,$,$); -#6816=IFCCLASSIFICATIONREFERENCE($,'23-29 33 13','Non Water Based Suppression Equipment',#6801,$,$); -#6817=IFCCLASSIFICATIONREFERENCE($,'23-29 33 13 11','Clean Agent Gaseous Suppression Equipment',#6816,$,$); -#6818=IFCCLASSIFICATIONREFERENCE($,'23-29 33 13 13','Carbon Dioxide Suppression Equipment',#6816,$,$); -#6819=IFCCLASSIFICATIONREFERENCE($,'23-29 33 13 15','Halon Suppression Equipment',#6816,$,$); -#6820=IFCCLASSIFICATIONREFERENCE($,'23-29 33 13 17','Wet Chemical Fire Suppression Equipment',#6816,$,$); -#6821=IFCCLASSIFICATIONREFERENCE($,'23-29 33 13 19','Dry Chemical Fire Suppression Equipment',#6816,$,$); -#6822=IFCCLASSIFICATIONREFERENCE($,'23-29 33 13 21','Foam Fire Suppression Equipment',#6816,$,$); -#6823=IFCCLASSIFICATIONREFERENCE($,'23-29 33 15','Fire Blankets',#6801,$,$); -#6824=IFCCLASSIFICATIONREFERENCE($,'23-29 35 00','Fire Rescue Component',#6606,$,$); -#6825=IFCCLASSIFICATIONREFERENCE($,'23-29 35 11','Evacuation Chairs',#6824,$,$); -#6826=IFCCLASSIFICATIONREFERENCE($,'23-29 35 13','Evacuation Slides',#6824,$,$); -#6827=IFCCLASSIFICATIONREFERENCE($,'23-29 37 00','Occupational Safety and Health Equipment',#6606,$,$); -#6828=IFCCLASSIFICATIONREFERENCE($,'23-29 37 11','Emergency Drench Hoses',#6827,$,$); -#6829=IFCCLASSIFICATIONREFERENCE($,'23-29 37 13','Emergency Eye Wash Stations',#6827,$,$); -#6830=IFCCLASSIFICATIONREFERENCE($,'23-29 37 13 11','Counter Top Eye Wash Stations',#6829,$,$); -#6831=IFCCLASSIFICATIONREFERENCE($,'23-29 37 13 13','Floor Mounted Eye Wash Stations',#6829,$,$); -#6832=IFCCLASSIFICATIONREFERENCE($,'23-29 37 13 15','Combination Emergency Eye Wash Stations',#6829,$,$); -#6833=IFCCLASSIFICATIONREFERENCE($,'23-29 37 13 17','Dedicated Emergency Eye Wash Stations',#6829,$,$); -#6834=IFCCLASSIFICATIONREFERENCE($,'23-29 37 15','Emergency Showers',#6827,$,$); -#6835=IFCCLASSIFICATIONREFERENCE($,'23-29 37 15 11','Combination Emergency Showers',#6834,$,$); -#6836=IFCCLASSIFICATIONREFERENCE($,'23-29 37 15 13','Dedicated Emergency Showers',#6834,$,$); -#6837=IFCCLASSIFICATIONREFERENCE($,'23-29 39 00','Environmental Safety Equipment',#6606,$,$); -#6838=IFCCLASSIFICATIONREFERENCE($,'23-29 39 11','Environmental Spill Kits',#6837,$,$); -#6839=IFCCLASSIFICATIONREFERENCE($,'23-29 39 13','Pollution Monitoring and Control',#6837,$,$); -#6840=IFCCLASSIFICATIONREFERENCE($,'23-29 39 13 11','Air Pollution Monitoring Systems',#6839,$,$); -#6841=IFCCLASSIFICATIONREFERENCE($,'23-29 39 13 13','Water Pollution Monitoring Systems',#6839,$,$); -#6842=IFCCLASSIFICATIONREFERENCE($,'23-29 39 15','Built In Failure Detection',#6837,$,$); -#6843=IFCCLASSIFICATIONREFERENCE($,'23-29 39 15 11','Infiltration Detection',#6842,$,$); -#6844=IFCCLASSIFICATIONREFERENCE($,'23-29 39 15 13','Service Leak Detection',#6842,$,$); -#6845=IFCCLASSIFICATIONREFERENCE($,'23-29 39 15 13 11','Gas Leak Detection Agents',#6844,$,$); -#6846=IFCCLASSIFICATIONREFERENCE($,'23-29 39 15 13 13','Water Leak Detection',#6844,$,$); -#6847=IFCCLASSIFICATIONREFERENCE($,'23-31 00 00','Plumbing Specific Products and Equipment',#1604,$,$); -#6848=IFCCLASSIFICATIONREFERENCE($,'23-31 11 00','Faucets',#6847,$,$); -#6849=IFCCLASSIFICATIONREFERENCE($,'23-31 11 11','Ball Faucets',#6848,$,$); -#6850=IFCCLASSIFICATIONREFERENCE($,'23-31 11 11 11','Sink Ball Faucets',#6849,$,$); -#6851=IFCCLASSIFICATIONREFERENCE($,'23-31 11 11 13','Bathtub Ball Faucets',#6849,$,$); -#6852=IFCCLASSIFICATIONREFERENCE($,'23-31 11 11 15','Shower Ball Faucets',#6849,$,$); -#6853=IFCCLASSIFICATIONREFERENCE($,'23-31 11 13','Compression Faucets',#6848,$,$); -#6854=IFCCLASSIFICATIONREFERENCE($,'23-31 11 13 11','Sink Compression Faucets',#6853,$,$); -#6855=IFCCLASSIFICATIONREFERENCE($,'23-31 11 13 13','Bathtub Compression Faucets',#6853,$,$); -#6856=IFCCLASSIFICATIONREFERENCE($,'23-31 11 13 15','Shower Compression Faucets',#6853,$,$); -#6857=IFCCLASSIFICATIONREFERENCE($,'23-31 11 15','Cartridge Faucets',#6848,$,$); -#6858=IFCCLASSIFICATIONREFERENCE($,'23-31 11 15 11','Sink Cartridge Faucets',#6857,$,$); -#6859=IFCCLASSIFICATIONREFERENCE($,'23-31 11 15 13','Bathtub Cartridge Faucets',#6857,$,$); -#6860=IFCCLASSIFICATIONREFERENCE($,'23-31 11 15 15','Shower Cartridge Faucets',#6857,$,$); -#6861=IFCCLASSIFICATIONREFERENCE($,'23-31 11 17','Disc Faucets',#6848,$,$); -#6862=IFCCLASSIFICATIONREFERENCE($,'23-31 11 17 11','Sink Disc Faucets',#6861,$,$); -#6863=IFCCLASSIFICATIONREFERENCE($,'23-31 11 17 13','Bathtub Disc Faucets',#6861,$,$); -#6864=IFCCLASSIFICATIONREFERENCE($,'23-31 11 17 15','Shower Disc Faucets',#6861,$,$); -#6865=IFCCLASSIFICATIONREFERENCE($,'23-31 11 19','Faucet Mixing Valves',#6848,$,$); -#6866=IFCCLASSIFICATIONREFERENCE($,'23-31 11 19 11','Thermostatically Controlled Faucet Mixing Valves',#6865,$,$); -#6867=IFCCLASSIFICATIONREFERENCE($,'23-31 11 19 13','Pressure Sensitive Faucet Mixing Valves',#6865,$,$); -#6868=IFCCLASSIFICATIONREFERENCE($,'23-31 11 19 15','Pressure Balanced Faucet Mixing Valves',#6865,$,$); -#6869=IFCCLASSIFICATIONREFERENCE($,'23-31 13 00','Sinks',#6847,$,$); -#6870=IFCCLASSIFICATIONREFERENCE($,'23-31 13 11','Single Sinks',#6869,$,$); -#6871=IFCCLASSIFICATIONREFERENCE($,'23-31 13 13','Dual Sinks',#6869,$,$); -#6872=IFCCLASSIFICATIONREFERENCE($,'23-31 13 15','Multiple Sinks',#6869,$,$); -#6873=IFCCLASSIFICATIONREFERENCE($,'23-31 13 17','Sink Components',#6869,$,$); -#6874=IFCCLASSIFICATIONREFERENCE($,'23-31 13 17 11','Sink Splashbacks',#6873,$,$); -#6875=IFCCLASSIFICATIONREFERENCE($,'23-31 13 17 13','Sink Drains',#6873,$,$); -#6876=IFCCLASSIFICATIONREFERENCE($,'23-31 13 19','Specialty Sinks',#6869,$,$); -#6877=IFCCLASSIFICATIONREFERENCE($,'23-31 13 19 11','Sacristy',#6876,$,$); -#6878=IFCCLASSIFICATIONREFERENCE($,'23-31 13 19 13','Darkroom Sinks',#6876,$,$); -#6879=IFCCLASSIFICATIONREFERENCE($,'23-31 13 19 15','Hairdressing Sinks',#6876,$,$); -#6880=IFCCLASSIFICATIONREFERENCE($,'23-31 13 19 17','Mop Sinks',#6876,$,$); -#6881=IFCCLASSIFICATIONREFERENCE($,'23-31 13 19 19','Service Sinks',#6876,$,$); -#6882=IFCCLASSIFICATIONREFERENCE($,'23-31 15 00','Bathtubs',#6847,$,$); -#6883=IFCCLASSIFICATIONREFERENCE($,'23-31 15 11','Bath Shower Units',#6882,$,$); -#6884=IFCCLASSIFICATIONREFERENCE($,'23-31 15 13','Sitz Baths',#6882,$,$); -#6885=IFCCLASSIFICATIONREFERENCE($,'23-31 15 15','Jacuzzi Baths',#6882,$,$); -#6886=IFCCLASSIFICATIONREFERENCE($,'23-31 15 17','Bathtub Components',#6882,$,$); -#6887=IFCCLASSIFICATIONREFERENCE($,'23-31 15 17 11','Bathtub Enclosures',#6886,$,$); -#6888=IFCCLASSIFICATIONREFERENCE($,'23-31 15 17 13','Bathtub Splashbacks',#6886,$,$); -#6889=IFCCLASSIFICATIONREFERENCE($,'23-31 15 17 15','Bathtub Panels',#6886,$,$); -#6890=IFCCLASSIFICATIONREFERENCE($,'23-31 15 17 17','Bathtub Seats',#6886,$,$); -#6891=IFCCLASSIFICATIONREFERENCE($,'23-31 15 17 19','Bathtub Screens',#6886,$,$); -#6892=IFCCLASSIFICATIONREFERENCE($,'23-31 15 17 21','Bathtub Grab Bars',#6886,$,$); -#6893=IFCCLASSIFICATIONREFERENCE($,'23-31 15 17 23','Bathtub Drains',#6886,$,$); -#6894=IFCCLASSIFICATIONREFERENCE($,'23-31 17 00','Showers',#6847,$,$); -#6895=IFCCLASSIFICATIONREFERENCE($,'23-31 17 11','Shower Compartments',#6894,$,$); -#6896=IFCCLASSIFICATIONREFERENCE($,'23-31 17 13','Shower Receptors',#6894,$,$); -#6897=IFCCLASSIFICATIONREFERENCE($,'23-31 17 15','Shower Enclosure Bases',#6894,$,$); -#6898=IFCCLASSIFICATIONREFERENCE($,'23-31 17 17','Shower Enclosures',#6894,$,$); -#6899=IFCCLASSIFICATIONREFERENCE($,'23-31 17 19','Shower Head Fixtures',#6894,$,$); -#6900=IFCCLASSIFICATIONREFERENCE($,'23-31 17 21','Shower Splashbacks',#6894,$,$); -#6901=IFCCLASSIFICATIONREFERENCE($,'23-31 17 23','Shower Seats',#6894,$,$); -#6902=IFCCLASSIFICATIONREFERENCE($,'23-31 17 25','Shower Screens',#6894,$,$); -#6903=IFCCLASSIFICATIONREFERENCE($,'23-31 17 27','Shower Curtains',#6894,$,$); -#6904=IFCCLASSIFICATIONREFERENCE($,'23-31 17 29','Shower Drains',#6894,$,$); -#6905=IFCCLASSIFICATIONREFERENCE($,'23-31 17 31','Shower Rods',#6894,$,$); -#6906=IFCCLASSIFICATIONREFERENCE($,'23-31 19 00','Toilets',#6847,$,$); -#6907=IFCCLASSIFICATIONREFERENCE($,'23-31 19 11','Combination Toilets',#6906,$,$); -#6908=IFCCLASSIFICATIONREFERENCE($,'23-31 19 11 11','Detention Combination Toilets',#6907,$,$); -#6909=IFCCLASSIFICATIONREFERENCE($,'23-31 19 13','Incinerating Toilets',#6906,$,$); -#6910=IFCCLASSIFICATIONREFERENCE($,'23-31 19 15','Tankless Toilets',#6906,$,$); -#6911=IFCCLASSIFICATIONREFERENCE($,'23-31 19 15 11','Floor Mounted Tankless Toilets',#6910,$,$); -#6912=IFCCLASSIFICATIONREFERENCE($,'23-31 19 15 13','Wall Mounted Tankless Toilets',#6910,$,$); -#6913=IFCCLASSIFICATIONREFERENCE($,'23-31 19 17','Toilets With Tank',#6906,$,$); -#6914=IFCCLASSIFICATIONREFERENCE($,'23-31 19 17 11','Floor Mounted Toilets With Tank',#6913,$,$); -#6915=IFCCLASSIFICATIONREFERENCE($,'23-31 19 17 13','Wall Mounted Toilets With Tank',#6913,$,$); -#6916=IFCCLASSIFICATIONREFERENCE($,'23-31 19 19','Water Closets',#6906,$,$); -#6917=IFCCLASSIFICATIONREFERENCE($,'23-31 19 19 11','Water Operated Water Closets',#6916,$,$); -#6918=IFCCLASSIFICATIONREFERENCE($,'23-31 19 19 13','Chemical Biological Sanitary Disposal Units',#6916,$,$); -#6919=IFCCLASSIFICATIONREFERENCE($,'23-31 19 19 15','Sanitary Macerators',#6916,$,$); -#6920=IFCCLASSIFICATIONREFERENCE($,'23-31 19 19 17','Water Closet Seats',#6916,$,$); -#6921=IFCCLASSIFICATIONREFERENCE($,'23-31 19 19 19','Water Closet Tanks',#6916,$,$); -#6922=IFCCLASSIFICATIONREFERENCE($,'23-31 19 19 21','Sanitary Disposal Connectors',#6916,$,$); -#6923=IFCCLASSIFICATIONREFERENCE($,'23-31 21 00','Urinals',#6847,$,$); -#6924=IFCCLASSIFICATIONREFERENCE($,'23-31 21 11','Incinerating Urinals',#6923,$,$); -#6925=IFCCLASSIFICATIONREFERENCE($,'23-31 21 13','Water Flush Urinals',#6923,$,$); -#6926=IFCCLASSIFICATIONREFERENCE($,'23-31 21 13 11','Floor Water Flush Urinals',#6925,$,$); -#6927=IFCCLASSIFICATIONREFERENCE($,'23-31 21 13 13','Wall Mounted Water Flush Urinals',#6925,$,$); -#6928=IFCCLASSIFICATIONREFERENCE($,'23-31 21 15','Waterless Urinals',#6923,$,$); -#6929=IFCCLASSIFICATIONREFERENCE($,'23-31 21 15 11','Floor Waterless Urinals',#6928,$,$); -#6930=IFCCLASSIFICATIONREFERENCE($,'23-31 21 15 13','Wall Mounted Waterless Urinals',#6928,$,$); -#6931=IFCCLASSIFICATIONREFERENCE($,'23-31 23 00','Bidets',#6847,$,$); -#6932=IFCCLASSIFICATIONREFERENCE($,'23-31 25 00','Toilet and Bath Specialties',#6847,$,$); -#6933=IFCCLASSIFICATIONREFERENCE($,'23-31 25 11','Restroom Partitions',#6932,$,$); -#6934=IFCCLASSIFICATIONREFERENCE($,'23-31 25 11 11','Toilet Partitions',#6933,$,$); -#6935=IFCCLASSIFICATIONREFERENCE($,'23-31 25 11 13','Toilet Door Partitions',#6933,$,$); -#6936=IFCCLASSIFICATIONREFERENCE($,'23-31 25 11 15','Urinal Partitions',#6933,$,$); -#6937=IFCCLASSIFICATIONREFERENCE($,'23-31 25 11 17','Shower Partitions',#6933,$,$); -#6938=IFCCLASSIFICATIONREFERENCE($,'23-31 25 13','Bathroom Cabinets',#6932,$,$); -#6939=IFCCLASSIFICATIONREFERENCE($,'23-31 25 15','Hand Dryers',#6932,$,$); -#6940=IFCCLASSIFICATIONREFERENCE($,'23-31 25 17','Hair Dryers',#6932,$,$); -#6941=IFCCLASSIFICATIONREFERENCE($,'23-31 25 19','Restroom Paper Towel Accessories',#6932,$,$); -#6942=IFCCLASSIFICATIONREFERENCE($,'23-31 25 19 11','Paper Towel Dispensers',#6941,$,$); -#6943=IFCCLASSIFICATIONREFERENCE($,'23-31 25 19 13','Paper Towel Dispenser With Disposal Units',#6941,$,$); -#6944=IFCCLASSIFICATIONREFERENCE($,'23-31 25 21','Toilet Paper Dispensers',#6932,$,$); -#6945=IFCCLASSIFICATIONREFERENCE($,'23-31 25 23','Feminine Hygiene Components',#6932,$,$); -#6946=IFCCLASSIFICATIONREFERENCE($,'23-31 25 23 11','Sanitary Napkin Dispensers',#6945,$,$); -#6947=IFCCLASSIFICATIONREFERENCE($,'23-31 25 23 13','Sanitary Napkin Dispenser With Disposal Units',#6945,$,$); -#6948=IFCCLASSIFICATIONREFERENCE($,'23-31 25 23 15','Tampon Dispensers',#6945,$,$); -#6949=IFCCLASSIFICATIONREFERENCE($,'23-31 25 23 17','Tampon Dispenser With Disposal Units',#6945,$,$); -#6950=IFCCLASSIFICATIONREFERENCE($,'23-31 25 23 19','Combination Sanitary Napkin and Tampon Dispensers',#6945,$,$); -#6951=IFCCLASSIFICATIONREFERENCE($,'23-31 25 23 21','Combination Sanitary Napkin and Tampon Dispenser With Disposal Units',#6945,$,$); -#6952=IFCCLASSIFICATIONREFERENCE($,'23-31 25 25','Towel Bars',#6932,$,$); -#6953=IFCCLASSIFICATIONREFERENCE($,'23-31 25 25 11','Electric Heated Towel Bars',#6952,$,$); -#6954=IFCCLASSIFICATIONREFERENCE($,'23-31 25 25 13','Water Heated Towel Bars',#6952,$,$); -#6955=IFCCLASSIFICATIONREFERENCE($,'23-31 25 27','Robe Hooks',#6932,$,$); -#6956=IFCCLASSIFICATIONREFERENCE($,'23-31 25 29','Restroom Hand Soap Components',#6932,$,$); -#6957=IFCCLASSIFICATIONREFERENCE($,'23-31 25 29 11','Hand Soap Holders',#6956,$,$); -#6958=IFCCLASSIFICATIONREFERENCE($,'23-31 25 29 13','Hand Soap Dispensers',#6956,$,$); -#6959=IFCCLASSIFICATIONREFERENCE($,'23-31 25 31','Diaper Changing Units',#6932,$,$); -#6960=IFCCLASSIFICATIONREFERENCE($,'23-31 25 33','Bathroom Deodorizers',#6932,$,$); -#6961=IFCCLASSIFICATIONREFERENCE($,'23-31 27 00','Floor Drains',#6847,$,$); -#6962=IFCCLASSIFICATIONREFERENCE($,'23-31 27 11','Floor Drain Plugs',#6961,$,$); -#6963=IFCCLASSIFICATIONREFERENCE($,'23-31 27 13','Floor Drain Plug Chains',#6961,$,$); -#6964=IFCCLASSIFICATIONREFERENCE($,'23-31 27 15','Floor Drain Covers',#6961,$,$); -#6965=IFCCLASSIFICATIONREFERENCE($,'23-31 29 00','Hot Water Heaters',#6847,$,$); -#6966=IFCCLASSIFICATIONREFERENCE($,'23-31 29 11','Instantaneous Hot Water Heaters',#6965,$,$); -#6967=IFCCLASSIFICATIONREFERENCE($,'23-31 29 11 11','Electric Instantaneous Hot Water Heaters',#6966,$,$); -#6968=IFCCLASSIFICATIONREFERENCE($,'23-31 29 11 13','Gas Instantaneous Hot Water Heaters',#6966,$,$); -#6969=IFCCLASSIFICATIONREFERENCE($,'23-31 29 13','Hot Water Tank Heaters',#6965,$,$); -#6970=IFCCLASSIFICATIONREFERENCE($,'23-31 29 13 11','Hot Water Tank Electric Heaters',#6969,$,$); -#6971=IFCCLASSIFICATIONREFERENCE($,'23-31 29 13 13','Hot Water Tank Gas Heaters',#6969,$,$); -#6972=IFCCLASSIFICATIONREFERENCE($,'23-31 29 13 15','Hot Water Tank Steam Heaters',#6969,$,$); -#6973=IFCCLASSIFICATIONREFERENCE($,'23-31 29 13 17','Hot Water Tank Fuel Oil Heaters',#6969,$,$); -#6974=IFCCLASSIFICATIONREFERENCE($,'23-31 31 00','Drinking Fountains',#6847,$,$); -#6975=IFCCLASSIFICATIONREFERENCE($,'23-31 31 11','Drinking Fountain With Coolers',#6974,$,$); -#6976=IFCCLASSIFICATIONREFERENCE($,'23-31 31 13','Drinking Fountains With Direct Expansion Cooling',#6974,$,$); -#6977=IFCCLASSIFICATIONREFERENCE($,'23-31 33 00','Complete Sanitary Suites',#6847,$,$); -#6978=IFCCLASSIFICATIONREFERENCE($,'23-31 33 11','Complete Bathroom Suites',#6977,$,$); -#6979=IFCCLASSIFICATIONREFERENCE($,'23-31 35 00','Plumbing Tubing',#6847,$,$); -#6980=IFCCLASSIFICATIONREFERENCE($,'23-31 35 11','Tubing Reducers',#6979,$,$); -#6981=IFCCLASSIFICATIONREFERENCE($,'23-31 35 13','Tubing Couplings',#6979,$,$); -#6982=IFCCLASSIFICATIONREFERENCE($,'23-31 35 15','Tubing Elbows',#6979,$,$); -#6983=IFCCLASSIFICATIONREFERENCE($,'23-31 35 17','Tubing Plugs',#6979,$,$); -#6984=IFCCLASSIFICATIONREFERENCE($,'23-31 35 19','Tubing Tees',#6979,$,$); -#6985=IFCCLASSIFICATIONREFERENCE($,'23-33 00 00','HVAC Specific Products and Equipment',#1604,$,$); -#6986=IFCCLASSIFICATIONREFERENCE($,'23-33 11 00','Commercial Boilers',#6985,$,$); -#6987=IFCCLASSIFICATIONREFERENCE($,'23-33 11 11','Boiler Controls',#6986,$,$); -#6988=IFCCLASSIFICATIONREFERENCE($,'23-33 11 11 11','Boiler Control Panels',#6987,$,$); -#6989=IFCCLASSIFICATIONREFERENCE($,'23-33 11 11 13','Boiler Burner Controls',#6987,$,$); -#6990=IFCCLASSIFICATIONREFERENCE($,'23-33 11 13','Condensing Boilers',#6986,$,$); -#6991=IFCCLASSIFICATIONREFERENCE($,'23-33 11 15','Fire Tube Boilers',#6986,$,$); -#6992=IFCCLASSIFICATIONREFERENCE($,'23-33 11 15 11','High Pressure Steam Fire Tube Boilers',#6991,$,$); -#6993=IFCCLASSIFICATIONREFERENCE($,'23-33 11 15 13','High Temperature Hot Water Fire Tube Boilers',#6991,$,$); -#6994=IFCCLASSIFICATIONREFERENCE($,'23-33 11 15 15','Low Pressure Steam Fire Tube Boilers',#6991,$,$); -#6995=IFCCLASSIFICATIONREFERENCE($,'23-33 11 15 17','Low Temperature Hot Water Fire Tube Boilers',#6991,$,$); -#6996=IFCCLASSIFICATIONREFERENCE($,'23-33 11 17','Flexible Tube Boilers',#6986,$,$); -#6997=IFCCLASSIFICATIONREFERENCE($,'23-33 11 17 11','High Pressure Steam Flexible Tube Boilers',#6996,$,$); -#6998=IFCCLASSIFICATIONREFERENCE($,'23-33 11 17 13','High Temperature Hot Water Flexible Tube Boilers',#6996,$,$); -#6999=IFCCLASSIFICATIONREFERENCE($,'23-33 11 17 15','Low Pressure Steam Flexible Tube Boilers',#6996,$,$); -#7000=IFCCLASSIFICATIONREFERENCE($,'23-33 11 17 17','Low Temperature Hot Water Flexible Tube Boilers',#6996,$,$); -#7001=IFCCLASSIFICATIONREFERENCE($,'23-33 11 19','Sectionalized Cast Iron Boilers',#6986,$,$); -#7002=IFCCLASSIFICATIONREFERENCE($,'23-33 11 19 11','Low Pressure Steam Sectionalized Cast Iron Boilers',#7001,$,$); -#7003=IFCCLASSIFICATIONREFERENCE($,'23-33 11 19 13','Low Temperature Hot Water Sectionalized Cast Iron Boilers',#7001,$,$); -#7004=IFCCLASSIFICATIONREFERENCE($,'23-33 11 21','Water Tube Boilers',#6986,$,$); -#7005=IFCCLASSIFICATIONREFERENCE($,'23-33 11 21 11','High Pressure Steam Water Tube Boilers',#7004,$,$); -#7006=IFCCLASSIFICATIONREFERENCE($,'23-33 11 21 13','High Temperature Hot Water Tube Boilers',#7004,$,$); -#7007=IFCCLASSIFICATIONREFERENCE($,'23-33 11 21 15','Low Pressure Steam Water Water Tube Boilers',#7004,$,$); -#7008=IFCCLASSIFICATIONREFERENCE($,'23-33 11 21 17','Low Temperature Hot Water Water Tube Boilers',#7004,$,$); -#7009=IFCCLASSIFICATIONREFERENCE($,'23-33 11 22','Electric Boilers',#6986,$,$); -#7010=IFCCLASSIFICATIONREFERENCE($,'23-33 11 23','Boiler Components',#6986,$,$); -#7011=IFCCLASSIFICATIONREFERENCE($,'23-33 11 23 11','Boiler Joint Fillers and Sealants',#7010,$,$); -#7012=IFCCLASSIFICATIONREFERENCE($,'23-33 11 23 13','Boiler Fuel Burners',#7010,$,$); -#7013=IFCCLASSIFICATIONREFERENCE($,'23-33 11 23 15','Boiler Fuel Oil Filters',#7010,$,$); -#7014=IFCCLASSIFICATIONREFERENCE($,'23-33 11 23 17','Boiler Nozzles',#7010,$,$); -#7015=IFCCLASSIFICATIONREFERENCE($,'23-33 11 23 19','Boiler Induction Blowers',#7010,$,$); -#7016=IFCCLASSIFICATIONREFERENCE($,'23-33 11 23 21','Boiler Fuel Gas Heat Recovery Devices',#7010,$,$); -#7017=IFCCLASSIFICATIONREFERENCE($,'23-33 11 23 23','Boiler Draft Fans',#7010,$,$); -#7018=IFCCLASSIFICATIONREFERENCE($,'23-33 13 00','Furnaces',#6985,$,$); -#7019=IFCCLASSIFICATIONREFERENCE($,'23-33 13 11','Furnace Controls',#7018,$,$); -#7020=IFCCLASSIFICATIONREFERENCE($,'23-33 13 11 11','Furnace Control Panels',#7019,$,$); -#7021=IFCCLASSIFICATIONREFERENCE($,'23-33 13 11 13','Furnace Burner Controls',#7019,$,$); -#7022=IFCCLASSIFICATIONREFERENCE($,'23-33 13 13','Coal Fired Furnaces',#7018,$,$); -#7023=IFCCLASSIFICATIONREFERENCE($,'23-33 13 15','Electric Resistance Furnaces',#7018,$,$); -#7024=IFCCLASSIFICATIONREFERENCE($,'23-33 13 17','Natural Gas Fired Furnaces',#7018,$,$); -#7025=IFCCLASSIFICATIONREFERENCE($,'23-33 13 19','Gasoline Fired Furnaces',#7018,$,$); -#7026=IFCCLASSIFICATIONREFERENCE($,'23-33 13 21','Fuel Oil Fired Furnaces',#7018,$,$); -#7027=IFCCLASSIFICATIONREFERENCE($,'23-33 13 23','Oil Fired Furnaces',#7018,$,$); -#7028=IFCCLASSIFICATIONREFERENCE($,'23-33 13 25','Propane Fired Furnaces',#7018,$,$); -#7029=IFCCLASSIFICATIONREFERENCE($,'23-33 13 27','Furnace Components',#7018,$,$); -#7030=IFCCLASSIFICATIONREFERENCE($,'23-33 13 27 11','Furnace Joint Fillers and Sealants',#7029,$,$); -#7031=IFCCLASSIFICATIONREFERENCE($,'23-33 13 27 13','Furnace Fuel Burners',#7029,$,$); -#7032=IFCCLASSIFICATIONREFERENCE($,'23-33 13 27 15','Furnace Fuel Oil Filters',#7029,$,$); -#7033=IFCCLASSIFICATIONREFERENCE($,'23-33 13 27 17','Furnace Nozzles',#7029,$,$); -#7034=IFCCLASSIFICATIONREFERENCE($,'23-33 13 27 19','Furnace Fuel Gas Heat Recovery Devices',#7029,$,$); -#7035=IFCCLASSIFICATIONREFERENCE($,'23-33 15 00','HVAC Heating Units',#6985,$,$); -#7036=IFCCLASSIFICATIONREFERENCE($,'23-33 15 11','Propane HVAC Heaters',#7035,$,$); -#7037=IFCCLASSIFICATIONREFERENCE($,'23-33 15 11 11','Indoor Propane HVAC Heaters',#7036,$,$); -#7038=IFCCLASSIFICATIONREFERENCE($,'23-33 15 11 13','Outdoor Propane HVAC Heaters',#7036,$,$); -#7039=IFCCLASSIFICATIONREFERENCE($,'23-33 15 13','Heating Stoves',#7035,$,$); -#7040=IFCCLASSIFICATIONREFERENCE($,'23-33 15 13 11','Cast Iron Heating Stoves',#7039,$,$); -#7041=IFCCLASSIFICATIONREFERENCE($,'23-33 15 13 13','Stone Heating Stoves',#7039,$,$); -#7042=IFCCLASSIFICATIONREFERENCE($,'23-33 15 13 15','Welded Steel Heating Stoves',#7039,$,$); -#7043=IFCCLASSIFICATIONREFERENCE($,'23-33 15 13 17','Heating Stove Components',#7039,$,$); -#7044=IFCCLASSIFICATIONREFERENCE($,'23-33 15 13 17 11','Heating Stove Fenders',#7043,$,$); -#7045=IFCCLASSIFICATIONREFERENCE($,'23-33 15 13 17 13','Heating Stove Hoods',#7043,$,$); -#7046=IFCCLASSIFICATIONREFERENCE($,'23-33 15 13 17 15','Heating Stove Pipes',#7043,$,$); -#7047=IFCCLASSIFICATIONREFERENCE($,'23-33 15 15','Specialized Surface Heating Products',#7035,$,$); -#7048=IFCCLASSIFICATIONREFERENCE($,'23-33 15 15 11','Heating Sheets',#7047,$,$); -#7049=IFCCLASSIFICATIONREFERENCE($,'23-33 15 15 11 11','Heating Sheets for Walls',#7048,$,$); -#7050=IFCCLASSIFICATIONREFERENCE($,'23-33 15 15 11 13','Heating Sheets for Ceilings',#7048,$,$); -#7051=IFCCLASSIFICATIONREFERENCE($,'23-33 15 15 11 15','Embedded Electric Heating Sheets',#7048,$,$); -#7052=IFCCLASSIFICATIONREFERENCE($,'23-33 15 15 11 17','Heating Sheets for Glazing',#7048,$,$); -#7053=IFCCLASSIFICATIONREFERENCE($,'23-33 15 15 13','Heating Cables',#7047,$,$); -#7054=IFCCLASSIFICATIONREFERENCE($,'23-33 15 15 15','Pipe Heat Tape',#7047,$,$); -#7055=IFCCLASSIFICATIONREFERENCE($,'23-33 15 15 17','Cable Heat Trace',#7047,$,$); -#7056=IFCCLASSIFICATIONREFERENCE($,'23-33 15 15 19','Heated Ceiling Panels',#7047,$,$); -#7057=IFCCLASSIFICATIONREFERENCE($,'23-33 15 15 21','Pipe Heat Tracing',#7047,$,$); -#7058=IFCCLASSIFICATIONREFERENCE($,'23-33 15 17','Fuel Fired HVAC Heaters',#7035,$,$); -#7059=IFCCLASSIFICATIONREFERENCE($,'23-33 15 17 11','Fuel Fired HVAC Duct Heaters',#7058,$,$); -#7060=IFCCLASSIFICATIONREFERENCE($,'23-33 15 17 13','Fuel Fired HVAC Radiant Heaters',#7058,$,$); -#7061=IFCCLASSIFICATIONREFERENCE($,'23-33 15 17 15','Fuel Fired HVAC Unit Heaters',#7058,$,$); -#7062=IFCCLASSIFICATIONREFERENCE($,'23-33 15 17 17','Fuel Fired HVAC Air Heaters',#7058,$,$); -#7063=IFCCLASSIFICATIONREFERENCE($,'23-33 15 19','Forced Air Fuel Fired HVAC Heaters',#7035,$,$); -#7064=IFCCLASSIFICATIONREFERENCE($,'23-33 15 19 11','Forced Air Fuel Fired HVAC Duct Heaters',#7063,$,$); -#7065=IFCCLASSIFICATIONREFERENCE($,'23-33 15 19 13','Forced Air Fuel Fired HVAC Radiant Heaters',#7063,$,$); -#7066=IFCCLASSIFICATIONREFERENCE($,'23-33 15 19 15','Forced Air Fuel Fired HVAC Unit Heaters',#7063,$,$); -#7067=IFCCLASSIFICATIONREFERENCE($,'23-33 15 19 17','Forced Air Fuel Fired HVAC Air Heaters',#7063,$,$); -#7068=IFCCLASSIFICATIONREFERENCE($,'23-33 15 21','Hydronic HVAC Heaters',#7035,$,$); -#7069=IFCCLASSIFICATIONREFERENCE($,'23-33 15 21 11','Cast Iron Radiators',#7068,$,$); -#7070=IFCCLASSIFICATIONREFERENCE($,'23-33 15 21 13','Finned Tube Radiators',#7068,$,$); -#7071=IFCCLASSIFICATIONREFERENCE($,'23-33 15 21 15','Plate Radiators',#7068,$,$); -#7072=IFCCLASSIFICATIONREFERENCE($,'23-33 15 21 17','Radiation Heating Panels',#7068,$,$); -#7073=IFCCLASSIFICATIONREFERENCE($,'23-33 15 23','Forced Air Hydronic HVAC Heaters',#7035,$,$); -#7074=IFCCLASSIFICATIONREFERENCE($,'23-33 15 23 11','Forced Air Cast Iron Radiators',#7073,$,$); -#7075=IFCCLASSIFICATIONREFERENCE($,'23-33 15 23 13','Forced Air Finned Tube Radiators',#7073,$,$); -#7076=IFCCLASSIFICATIONREFERENCE($,'23-33 15 23 15','Forced Air Plate Radiators',#7073,$,$); -#7077=IFCCLASSIFICATIONREFERENCE($,'23-33 15 23 17','Forced Air Radiation Heating Panels',#7073,$,$); -#7078=IFCCLASSIFICATIONREFERENCE($,'23-33 15 25','Electric HVAC Heaters',#7035,$,$); -#7079=IFCCLASSIFICATIONREFERENCE($,'23-33 15 25 11','Halogen Electric HVAC Heaters',#7078,$,$); -#7080=IFCCLASSIFICATIONREFERENCE($,'23-33 15 25 13','Infrared Plate HVAC Heaters',#7078,$,$); -#7081=IFCCLASSIFICATIONREFERENCE($,'23-33 15 25 15','Ultraviolet HVAC Heaters',#7078,$,$); -#7082=IFCCLASSIFICATIONREFERENCE($,'23-33 15 25 17','Electric HVAC Resistive Unit Heaters',#7078,$,$); -#7083=IFCCLASSIFICATIONREFERENCE($,'23-33 15 27','Forced Air Electric HVAC Heaters',#7035,$,$); -#7084=IFCCLASSIFICATIONREFERENCE($,'23-33 15 27 11','Forced Air Halogen Electric HVAC Heaters',#7083,$,$); -#7085=IFCCLASSIFICATIONREFERENCE($,'23-33 15 27 13','Forced Air Infrared Plate HVAC Heaters',#7083,$,$); -#7086=IFCCLASSIFICATIONREFERENCE($,'23-33 15 27 15','Forced Air Ultraviolet HVAC Heaters',#7083,$,$); -#7087=IFCCLASSIFICATIONREFERENCE($,'23-33 15 27 17','Forced Air Electric HVAC Resitive Unit Heaters',#7083,$,$); -#7088=IFCCLASSIFICATIONREFERENCE($,'23-33 15 29','HVAC Steam Hot Water Converters',#7035,$,$); -#7089=IFCCLASSIFICATIONREFERENCE($,'23-33 17 00','Heat Pumps',#6985,$,$); -#7090=IFCCLASSIFICATIONREFERENCE($,'23-33 17 11','Packaged Heat Pumps',#7089,$,$); -#7091=IFCCLASSIFICATIONREFERENCE($,'23-33 17 11 11','Air Source Packaged Heat Pumps',#7090,$,$); -#7092=IFCCLASSIFICATIONREFERENCE($,'23-33 17 11 13','Water Source Packaged Heat Pumps',#7090,$,$); -#7093=IFCCLASSIFICATIONREFERENCE($,'23-33 17 13','Split System Heat Pumps',#7089,$,$); -#7094=IFCCLASSIFICATIONREFERENCE($,'23-33 17 13 11','Air Source Split System Heat Pumps',#7093,$,$); -#7095=IFCCLASSIFICATIONREFERENCE($,'23-33 17 13 13','Water Source Split System Heat Pumps',#7093,$,$); -#7096=IFCCLASSIFICATIONREFERENCE($,'23-33 19 00','Cooling and Freeze Components',#6985,$,$); -#7097=IFCCLASSIFICATIONREFERENCE($,'23-33 19 11','Cooling Freeze Plant Accessories',#7096,$,$); -#7098=IFCCLASSIFICATIONREFERENCE($,'23-33 19 11 11','Refrigerant Liquid',#7097,$,$); -#7099=IFCCLASSIFICATIONREFERENCE($,'23-33 21 00','Chillers',#6985,$,$); -#7100=IFCCLASSIFICATIONREFERENCE($,'23-33 21 11','Absorption Chillers',#7099,$,$); -#7101=IFCCLASSIFICATIONREFERENCE($,'23-33 21 11 11','Direct Fired Absorption Chillers',#7100,$,$); -#7102=IFCCLASSIFICATIONREFERENCE($,'23-33 21 11 13','Steam Absorption Chillers',#7100,$,$); -#7103=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13','Chillers',#7099,$,$); -#7104=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 11','Central Package Unit Chillers',#7103,$,$); -#7105=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 13','Centrifugal Chillers',#7103,$,$); -#7106=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 13 11','Packaged Centrifugal Chillers',#7105,$,$); -#7107=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 13 13','Split System Centrifugal Chillers',#7105,$,$); -#7108=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 15','Reciprocating Chillers',#7103,$,$); -#7109=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 15 11','Packaged Reciprocating Chillers',#7108,$,$); -#7110=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 15 13','Split System Reciprocating Chillers',#7108,$,$); -#7111=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 17','Rotary Chillers',#7103,$,$); -#7112=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 17 11','Packaged Rotary Chillers',#7111,$,$); -#7113=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 17 13','Split System Rotary Chillers',#7111,$,$); -#7114=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 19','Rotary Screw Chillers',#7103,$,$); -#7115=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 19 11','Packaged Rotary Screw Chillers',#7114,$,$); -#7116=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 19 13','Split System Rotary Screw Chillers',#7114,$,$); -#7117=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 21','Screw Chillers',#7103,$,$); -#7118=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 21 11','Packaged Screw Chillers',#7117,$,$); -#7119=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 21 13','Split System Screw Chillers',#7117,$,$); -#7120=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 23','Scroll Chillers',#7103,$,$); -#7121=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 23 11','Packaged Scroll Chillers',#7120,$,$); -#7122=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 23 13','Split System Scroll Chillers',#7120,$,$); -#7123=IFCCLASSIFICATIONREFERENCE($,'23-33 23 00','Cooling Towers',#6985,$,$); -#7124=IFCCLASSIFICATIONREFERENCE($,'23-33 23 11','Mechanical Draft Cooling Towers',#7123,$,$); -#7125=IFCCLASSIFICATIONREFERENCE($,'23-33 23 13','Natural Draft Cooling Towers',#7123,$,$); -#7126=IFCCLASSIFICATIONREFERENCE($,'23-33 23 15','Cooling Ponds',#7123,$,$); -#7127=IFCCLASSIFICATIONREFERENCE($,'23-33 25 00','Air Handling Units',#6985,$,$); -#7128=IFCCLASSIFICATIONREFERENCE($,'23-33 25 11','Built Up Air Handling Units',#7127,$,$); -#7129=IFCCLASSIFICATIONREFERENCE($,'23-33 25 11 11','Built Up Indoor Air Handling Units',#7128,$,$); -#7130=IFCCLASSIFICATIONREFERENCE($,'23-33 25 11 13','Built Up Rooftop Air Handling Units',#7128,$,$); -#7131=IFCCLASSIFICATIONREFERENCE($,'23-33 25 13','Customized Air Handling Units',#7127,$,$); -#7132=IFCCLASSIFICATIONREFERENCE($,'23-33 25 13 11','Customized Indoor Air Handling Units',#7131,$,$); -#7133=IFCCLASSIFICATIONREFERENCE($,'23-33 25 13 13','Customized Rooftop Air Handling Units',#7131,$,$); -#7134=IFCCLASSIFICATIONREFERENCE($,'23-33 25 15','Heating and Ventilating Units',#7127,$,$); -#7135=IFCCLASSIFICATIONREFERENCE($,'23-33 25 17','Modular Air Handling Units',#7127,$,$); -#7136=IFCCLASSIFICATIONREFERENCE($,'23-33 25 17 11','Modular Indoor Air Handling Units',#7135,$,$); -#7137=IFCCLASSIFICATIONREFERENCE($,'23-33 25 17 13','Modular Rooftop Air Handling Units',#7135,$,$); -#7138=IFCCLASSIFICATIONREFERENCE($,'23-33 25 19','Pre Fabricated Air Handling Units',#7127,$,$); -#7139=IFCCLASSIFICATIONREFERENCE($,'23-33 27 00','Air Humidity Control Equipment',#6985,$,$); -#7140=IFCCLASSIFICATIONREFERENCE($,'23-33 27 11','Air Washers',#7139,$,$); -#7141=IFCCLASSIFICATIONREFERENCE($,'23-33 27 11 11','Convection Air Washers',#7140,$,$); -#7142=IFCCLASSIFICATIONREFERENCE($,'23-33 27 11 13','Evaporative Air Washers',#7140,$,$); -#7143=IFCCLASSIFICATIONREFERENCE($,'23-33 27 13','Dehumidifiers',#7139,$,$); -#7144=IFCCLASSIFICATIONREFERENCE($,'23-33 27 13 11','Dehumidifiers',#7143,$,$); -#7145=IFCCLASSIFICATIONREFERENCE($,'23-33 27 13 11 11','Swimming Pool Dehumidification Units',#7144,$,$); -#7146=IFCCLASSIFICATIONREFERENCE($,'23-33 27 13 13','Permanently Installed Dehumidifiers',#7143,$,$); -#7147=IFCCLASSIFICATIONREFERENCE($,'23-33 27 13 15','Portable Dehumidifiers',#7143,$,$); -#7148=IFCCLASSIFICATIONREFERENCE($,'23-33 27 15','Air Humidifiers',#7139,$,$); -#7149=IFCCLASSIFICATIONREFERENCE($,'23-33 27 17','Vaporizers',#7139,$,$); -#7150=IFCCLASSIFICATIONREFERENCE($,'23-33 29 00','HVAC Dampers',#6985,$,$); -#7151=IFCCLASSIFICATIONREFERENCE($,'23-33 29 11','3 Way Diverter Dampers',#7150,$,$); -#7152=IFCCLASSIFICATIONREFERENCE($,'23-33 29 13','Backdraft Dampers',#7150,$,$); -#7153=IFCCLASSIFICATIONREFERENCE($,'23-33 29 13 11','Opposed Blade Backdraft Dampers',#7152,$,$); -#7154=IFCCLASSIFICATIONREFERENCE($,'23-33 29 13 11 11','Spring Loaded Opposed Blade Backdraft Dampers',#7153,$,$); -#7155=IFCCLASSIFICATIONREFERENCE($,'23-33 29 13 11 13','Counter Weight Balanced Opposed Blade Backdraft Dampers',#7153,$,$); -#7156=IFCCLASSIFICATIONREFERENCE($,'23-33 29 13 13','Parallel Backdraft Dampers',#7152,$,$); -#7157=IFCCLASSIFICATIONREFERENCE($,'23-33 29 13 13 11','Spring Loaded Parallel Backdraft Dampers',#7156,$,$); -#7158=IFCCLASSIFICATIONREFERENCE($,'23-33 29 13 13 13','Counter Weight Balanced Parallel Backdraft Dampers',#7156,$,$); -#7159=IFCCLASSIFICATIONREFERENCE($,'23-33 29 15','Bi Plane Dampers',#7150,$,$); -#7160=IFCCLASSIFICATIONREFERENCE($,'23-33 29 17','Butterfly Dampers',#7150,$,$); -#7161=IFCCLASSIFICATIONREFERENCE($,'23-33 29 17 11','Automatically Control Butterfly Dampers',#7160,$,$); -#7162=IFCCLASSIFICATIONREFERENCE($,'23-33 29 17 13','Manual Butterfly Dampers',#7160,$,$); -#7163=IFCCLASSIFICATIONREFERENCE($,'23-33 29 19','Dampers',#7150,$,$); -#7164=IFCCLASSIFICATIONREFERENCE($,'23-33 29 19 11','Automatically Control Dampers',#7163,$,$); -#7165=IFCCLASSIFICATIONREFERENCE($,'23-33 29 19 13','Manual Dampers',#7163,$,$); -#7166=IFCCLASSIFICATIONREFERENCE($,'23-33 29 21','Diffuser Firestop Flaps',#7150,$,$); -#7167=IFCCLASSIFICATIONREFERENCE($,'23-33 29 23','Fire Dampers',#7150,$,$); -#7168=IFCCLASSIFICATIONREFERENCE($,'23-33 29 23 11','Manual Fire Dampers',#7167,$,$); -#7169=IFCCLASSIFICATIONREFERENCE($,'23-33 29 23 13','Automatic Fire Dampers',#7167,$,$); -#7170=IFCCLASSIFICATIONREFERENCE($,'23-33 29 25','Smoke Dampers',#7150,$,$); -#7171=IFCCLASSIFICATIONREFERENCE($,'23-33 29 25 11','Manual Smoke Dampers',#7170,$,$); -#7172=IFCCLASSIFICATIONREFERENCE($,'23-33 29 25 13','Automatic Smoke Dampers',#7170,$,$); -#7173=IFCCLASSIFICATIONREFERENCE($,'23-33 29 27','Non Return Dampers',#7150,$,$); -#7174=IFCCLASSIFICATIONREFERENCE($,'23-33 29 29','Guillotine Dampers',#7150,$,$); -#7175=IFCCLASSIFICATIONREFERENCE($,'23-33 29 31','Louvre Dampers',#7150,$,$); -#7176=IFCCLASSIFICATIONREFERENCE($,'23-33 29 31 11','Louvre Dampers with Opposed Blade Motion',#7175,$,$); -#7177=IFCCLASSIFICATIONREFERENCE($,'23-33 29 33','Movable Blade Wall Louvers',#7150,$,$); -#7178=IFCCLASSIFICATIONREFERENCE($,'23-33 29 33 11','Double Panel Wall Louvers',#7177,$,$); -#7179=IFCCLASSIFICATIONREFERENCE($,'23-33 29 35','Static Pressure Regulating Dampers',#7150,$,$); -#7180=IFCCLASSIFICATIONREFERENCE($,'23-33 29 37','Volume Control Dampers',#7150,$,$); -#7181=IFCCLASSIFICATIONREFERENCE($,'23-33 29 37 11','Opposed Blade Volume Control Dampers',#7180,$,$); -#7182=IFCCLASSIFICATIONREFERENCE($,'23-33 29 37 11 11','Manual Opposed Blade Volume Control Dampers',#7181,$,$); -#7183=IFCCLASSIFICATIONREFERENCE($,'23-33 29 37 11 13','Automatic Opposed Blade Volume Control Dampers',#7181,$,$); -#7184=IFCCLASSIFICATIONREFERENCE($,'23-33 29 37 13','Parallel Volume Control Dampers',#7180,$,$); -#7185=IFCCLASSIFICATIONREFERENCE($,'23-33 29 37 13 11','Manual Parallel Volume Control Dampers',#7184,$,$); -#7186=IFCCLASSIFICATIONREFERENCE($,'23-33 29 37 13 13','Automatic Parallel Volume Control Dampers',#7184,$,$); -#7187=IFCCLASSIFICATIONREFERENCE($,'23-33 29 39','Fire Shutters for Air Ductwork',#7150,$,$); -#7188=IFCCLASSIFICATIONREFERENCE($,'23-33 31 00','Air Circulators',#6985,$,$); -#7189=IFCCLASSIFICATIONREFERENCE($,'23-33 31 11','Air Curtains',#7188,$,$); -#7190=IFCCLASSIFICATIONREFERENCE($,'23-33 31 11 11','Heated Air Curtains',#7189,$,$); -#7191=IFCCLASSIFICATIONREFERENCE($,'23-33 31 11 13','Non Heated Air Curtains',#7189,$,$); -#7192=IFCCLASSIFICATIONREFERENCE($,'23-33 31 13','Blowers',#7188,$,$); -#7193=IFCCLASSIFICATIONREFERENCE($,'23-33 31 13 11','Permanently Installed Blowers',#7192,$,$); -#7194=IFCCLASSIFICATIONREFERENCE($,'23-33 31 13 13','Portable Blowers',#7192,$,$); -#7195=IFCCLASSIFICATIONREFERENCE($,'23-33 31 15','Exhaust Hoods',#7188,$,$); -#7196=IFCCLASSIFICATIONREFERENCE($,'23-33 31 15 11','Canopy Exhaust Hoods',#7195,$,$); -#7197=IFCCLASSIFICATIONREFERENCE($,'23-33 31 15 13','Chemical Fume Hoods',#7195,$,$); -#7198=IFCCLASSIFICATIONREFERENCE($,'23-33 31 15 15','Perchloric Acid Fume Hoods',#7195,$,$); -#7199=IFCCLASSIFICATIONREFERENCE($,'23-33 31 15 17','Radio Isotope Fume Hoods',#7195,$,$); -#7200=IFCCLASSIFICATIONREFERENCE($,'23-33 31 15 19','Snorkel Exhaust Hoods',#7195,$,$); -#7201=IFCCLASSIFICATIONREFERENCE($,'23-33 31 15 21','Grease Exhaust Hoods',#7195,$,$); -#7202=IFCCLASSIFICATIONREFERENCE($,'23-33 31 17','Exhaust Hood Fire Suppression System',#7188,$,$); -#7203=IFCCLASSIFICATIONREFERENCE($,'23-33 31 17 11','Chemical Exhaust Hood Fire Suppression Systems',#7202,$,$); -#7204=IFCCLASSIFICATIONREFERENCE($,'23-33 31 17 13','Gas Exhaust Hood Fire Suppression Systems',#7202,$,$); -#7205=IFCCLASSIFICATIONREFERENCE($,'23-33 31 19','Fans',#7188,$,$); -#7206=IFCCLASSIFICATIONREFERENCE($,'23-33 31 19 11','Axial Fans',#7205,$,$); -#7207=IFCCLASSIFICATIONREFERENCE($,'23-33 31 19 11 11','Axial Plug Fans',#7206,$,$); -#7208=IFCCLASSIFICATIONREFERENCE($,'23-33 31 19 11 13','Axial Vane Fans',#7206,$,$); -#7209=IFCCLASSIFICATIONREFERENCE($,'23-33 31 19 11 15','Ceiling Fans',#7206,$,$); -#7210=IFCCLASSIFICATIONREFERENCE($,'23-33 31 19 11 17','Propeller Fans',#7206,$,$); -#7211=IFCCLASSIFICATIONREFERENCE($,'23-33 31 19 11 19','Tube Axial Fans',#7206,$,$); -#7212=IFCCLASSIFICATIONREFERENCE($,'23-33 31 19 11 21','Variable Pitch Axial Vane Fans',#7206,$,$); -#7213=IFCCLASSIFICATIONREFERENCE($,'23-33 31 19 13','Centrifugal Fans',#7205,$,$); -#7214=IFCCLASSIFICATIONREFERENCE($,'23-33 31 19 13 11','Centrifugal Plug Fans',#7213,$,$); -#7215=IFCCLASSIFICATIONREFERENCE($,'23-33 31 19 13 13','Double Inlet Centrifugal Fans',#7213,$,$); -#7216=IFCCLASSIFICATIONREFERENCE($,'23-33 31 19 13 15','Single Inlet Centrifugal Fans',#7213,$,$); -#7217=IFCCLASSIFICATIONREFERENCE($,'23-33 31 21','Power Ventilators',#7188,$,$); -#7218=IFCCLASSIFICATIONREFERENCE($,'23-33 31 21 11','Centrifugal Power Ventilators',#7217,$,$); -#7219=IFCCLASSIFICATIONREFERENCE($,'23-33 31 21 11 11','Down Blast Centrifugal Power Ventilators',#7218,$,$); -#7220=IFCCLASSIFICATIONREFERENCE($,'23-33 31 21 11 13','Up Blast Centrifugal Power Ventilators',#7218,$,$); -#7221=IFCCLASSIFICATIONREFERENCE($,'23-33 31 21 13','Propeller Power Ventilators',#7217,$,$); -#7222=IFCCLASSIFICATIONREFERENCE($,'23-33 31 21 13 11','Down Blast Propeller Power Ventilators',#7221,$,$); -#7223=IFCCLASSIFICATIONREFERENCE($,'23-33 31 21 13 13','Up Blast Propeller Power Ventilators',#7221,$,$); -#7224=IFCCLASSIFICATIONREFERENCE($,'23-33 33 00','HVAC Fan Coil Units',#6985,$,$); -#7225=IFCCLASSIFICATIONREFERENCE($,'23-33 33 11','Fan Coil Units',#7224,$,$); -#7226=IFCCLASSIFICATIONREFERENCE($,'23-33 33 11 11','Fan Coil Cooling Units',#7225,$,$); -#7227=IFCCLASSIFICATIONREFERENCE($,'23-33 33 11 11 11','2 Pipe Fan Coil Cooling Units',#7226,$,$); -#7228=IFCCLASSIFICATIONREFERENCE($,'23-33 33 11 11 13','4 Pipe Fan Coil Cooling Units',#7226,$,$); -#7229=IFCCLASSIFICATIONREFERENCE($,'23-33 33 11 13','Fan Coil Heating Units',#7225,$,$); -#7230=IFCCLASSIFICATIONREFERENCE($,'23-33 33 11 13 11','4 Pipe Fan Coil Heating Units',#7229,$,$); -#7231=IFCCLASSIFICATIONREFERENCE($,'23-33 33 11 13 13','2 Pipe Fan Coil Heating Units',#7229,$,$); -#7232=IFCCLASSIFICATIONREFERENCE($,'23-33 33 11 15','Fan Coil Heating and Cooling Units',#7225,$,$); -#7233=IFCCLASSIFICATIONREFERENCE($,'23-33 33 11 15 11','2 Pipe Fan Coil Heating and Cooling Units',#7232,$,$); -#7234=IFCCLASSIFICATIONREFERENCE($,'23-33 33 11 15 13','4 Pipe Fan Coil Heating and Cooling Units',#7232,$,$); -#7235=IFCCLASSIFICATIONREFERENCE($,'23-33 35 00','HVAC Coils',#6985,$,$); -#7236=IFCCLASSIFICATIONREFERENCE($,'23-33 35 11','HVAC Coils',#7235,$,$); -#7237=IFCCLASSIFICATIONREFERENCE($,'23-33 35 11 11','HVAC Glycol Coils',#7236,$,$); -#7238=IFCCLASSIFICATIONREFERENCE($,'23-33 35 11 13','HVAC Steam Coils',#7236,$,$); -#7239=IFCCLASSIFICATIONREFERENCE($,'23-33 35 11 15','HVAC Water Coils',#7236,$,$); -#7240=IFCCLASSIFICATIONREFERENCE($,'23-33 37 00','Refrigerant Condensing Units',#6985,$,$); -#7241=IFCCLASSIFICATIONREFERENCE($,'23-33 37 11','Packaged Refrigerant Coils and Fan Units',#7240,$,$); -#7242=IFCCLASSIFICATIONREFERENCE($,'23-33 37 13','Refrigerant Condensing Coils',#7240,$,$); -#7243=IFCCLASSIFICATIONREFERENCE($,'23-33 37 15','Refrigerant Evaporators',#7240,$,$); -#7244=IFCCLASSIFICATIONREFERENCE($,'23-33 39 00','Air Conditioning Equipment',#6985,$,$); -#7245=IFCCLASSIFICATIONREFERENCE($,'23-33 39 11','Air Conditioners',#7244,$,$); -#7246=IFCCLASSIFICATIONREFERENCE($,'23-33 39 11 11','Room Air Conditioners',#7245,$,$); -#7247=IFCCLASSIFICATIONREFERENCE($,'23-33 39 13','High Pressure Air Conditioning Units',#7244,$,$); -#7248=IFCCLASSIFICATIONREFERENCE($,'23-33 39 15','Make Up Air Units',#7244,$,$); -#7249=IFCCLASSIFICATIONREFERENCE($,'23-33 39 15 11','Make Up Air Units With Heat',#7248,$,$); -#7250=IFCCLASSIFICATIONREFERENCE($,'23-33 39 15 13','Make Up Air Units Without Heat',#7248,$,$); -#7251=IFCCLASSIFICATIONREFERENCE($,'23-33 39 17','Packaged Air Conditioners',#7244,$,$); -#7252=IFCCLASSIFICATIONREFERENCE($,'23-33 39 17 11','Dual Pack Packaged Air Conditioners',#7251,$,$); -#7253=IFCCLASSIFICATIONREFERENCE($,'23-33 39 17 11 11','Air Cooled Dual Pack Packaged Air Conditioners',#7252,$,$); -#7254=IFCCLASSIFICATIONREFERENCE($,'23-33 39 17 11 13','Water Cooled Dual Pack Packaged Air Conditioners',#7252,$,$); -#7255=IFCCLASSIFICATIONREFERENCE($,'23-33 39 17 13','Single Pack Packaged Air Conditioners',#7251,$,$); -#7256=IFCCLASSIFICATIONREFERENCE($,'23-33 39 17 13 11','Air Cooled Single Pack Packaged Air Conditioners',#7255,$,$); -#7257=IFCCLASSIFICATIONREFERENCE($,'23-33 39 17 13 13','Water Cooled Single Pack Packaged Air Conditioners',#7255,$,$); -#7258=IFCCLASSIFICATIONREFERENCE($,'23-33 39 17 13 15','Unitary Air Conditioning Equipment',#7255,$,$); -#7259=IFCCLASSIFICATIONREFERENCE($,'23-33 39 19','Packaged Terminal Air Conditioning Units',#7244,$,$); -#7260=IFCCLASSIFICATIONREFERENCE($,'23-33 39 19 11','Fixed Packaged Terminal Air Conditioners',#7259,$,$); -#7261=IFCCLASSIFICATIONREFERENCE($,'23-33 39 19 11 11','Air Cooled Fixed Packaged Terminal Air Conditioners',#7260,$,$); -#7262=IFCCLASSIFICATIONREFERENCE($,'23-33 39 19 11 13','Water Cooled Fixed Packaged Terminal Air Conditioners',#7260,$,$); -#7263=IFCCLASSIFICATIONREFERENCE($,'23-33 39 19 13','Portable Packaged Terminal Air Conditioners',#7259,$,$); -#7264=IFCCLASSIFICATIONREFERENCE($,'23-33 39 19 13 11','Air Cooled Portable Packaged Terminal Air Conditioners',#7263,$,$); -#7265=IFCCLASSIFICATIONREFERENCE($,'23-33 39 19 13 13','Water Cooled Portable Packaged Terminal Air Conditioners',#7263,$,$); -#7266=IFCCLASSIFICATIONREFERENCE($,'23-33 39 19 15','Window Packaged Terminal Air Conditioners',#7259,$,$); -#7267=IFCCLASSIFICATIONREFERENCE($,'23-33 39 19 15 11','Air Cooled Window Packaged Terminal Air Conditioners',#7266,$,$); -#7268=IFCCLASSIFICATIONREFERENCE($,'23-33 39 19 15 13','Water Cooled Window Packaged Terminal Air Conditioners',#7266,$,$); -#7269=IFCCLASSIFICATIONREFERENCE($,'23-33 39 21','Split System Air Conditioning Units',#7244,$,$); -#7270=IFCCLASSIFICATIONREFERENCE($,'23-33 41 00','HVAC Air Terminals',#6985,$,$); -#7271=IFCCLASSIFICATIONREFERENCE($,'23-33 41 11','Fan Powered Terminal Air Units',#7270,$,$); -#7272=IFCCLASSIFICATIONREFERENCE($,'23-33 41 11 11','Mixing Fan Powered Terminal Air Units',#7271,$,$); -#7273=IFCCLASSIFICATIONREFERENCE($,'23-33 41 11 11 11','Single Duct Mixing Fan Powered Terminal Air Units',#7272,$,$); -#7274=IFCCLASSIFICATIONREFERENCE($,'23-33 41 11 11 13','Dual Duct Mixing Fan Powered Terminal Air Units',#7272,$,$); -#7275=IFCCLASSIFICATIONREFERENCE($,'23-33 41 11 13','Non Mixing Fan Powered Terminal Air Units',#7271,$,$); -#7276=IFCCLASSIFICATIONREFERENCE($,'23-33 41 11 13 11','Single Duct Mixing Fan Powered Terminal Air Units',#7275,$,$); -#7277=IFCCLASSIFICATIONREFERENCE($,'23-33 41 11 13 13','Dual Duct Mixing Fan Powered Terminal Air Units',#7275,$,$); -#7278=IFCCLASSIFICATIONREFERENCE($,'23-33 41 13','Induction Terminal Air Units',#7270,$,$); -#7279=IFCCLASSIFICATIONREFERENCE($,'23-33 41 13 11','Constant Volume Air Induction Terminal Air Units',#7278,$,$); -#7280=IFCCLASSIFICATIONREFERENCE($,'23-33 41 13 11 11','Single Duct Constant Volume Air Induction Terminal Air Units',#7279,$,$); -#7281=IFCCLASSIFICATIONREFERENCE($,'23-33 41 13 11 13','Dual Duct Constant Volume Air Induction Terminal Air Units',#7279,$,$); -#7282=IFCCLASSIFICATIONREFERENCE($,'23-33 41 13 13','Variable Air Volume Induction Terminal Air Units',#7278,$,$); -#7283=IFCCLASSIFICATIONREFERENCE($,'23-33 41 13 13 11','Single Duct Variable Air Volume Induction Terminal Air Units',#7282,$,$); -#7284=IFCCLASSIFICATIONREFERENCE($,'23-33 41 13 13 13','Dual Duct Variable Air Volume Induction Terminal Air Units',#7282,$,$); -#7285=IFCCLASSIFICATIONREFERENCE($,'23-33 41 15','HVAC Mixing Boxes',#7270,$,$); -#7286=IFCCLASSIFICATIONREFERENCE($,'23-33 41 17','Terminal Air Units',#7270,$,$); -#7287=IFCCLASSIFICATIONREFERENCE($,'23-33 41 17 11','Constant Volume Air Terminal Units',#7286,$,$); -#7288=IFCCLASSIFICATIONREFERENCE($,'23-33 41 17 11 11','Dual Duct Constant Volume Air Terminal Units',#7287,$,$); -#7289=IFCCLASSIFICATIONREFERENCE($,'23-33 41 17 11 13','Single Duct Constant Volume Air Terminal Units',#7287,$,$); -#7290=IFCCLASSIFICATIONREFERENCE($,'23-33 41 17 13','Variable Air Volume Terminal Units',#7286,$,$); -#7291=IFCCLASSIFICATIONREFERENCE($,'23-33 41 17 13 11','Dual Duct Variable Air Volume Terminal Units',#7290,$,$); -#7292=IFCCLASSIFICATIONREFERENCE($,'23-33 41 17 13 13','Single Duct Variable Air Volume Terminal Units',#7290,$,$); -#7293=IFCCLASSIFICATIONREFERENCE($,'23-33 41 19','Exhaust Terminals',#7270,$,$); -#7294=IFCCLASSIFICATIONREFERENCE($,'23-33 43 00','HVAC Condenser Units',#6985,$,$); -#7295=IFCCLASSIFICATIONREFERENCE($,'23-33 43 11','Air Cooled Condenser Units',#7294,$,$); -#7296=IFCCLASSIFICATIONREFERENCE($,'23-33 43 11 11','Indoor Air Cooled Condenser Units',#7295,$,$); -#7297=IFCCLASSIFICATIONREFERENCE($,'23-33 43 11 13','Outdoor Air Cooled Condenser Units',#7295,$,$); -#7298=IFCCLASSIFICATIONREFERENCE($,'23-33 43 13','Evaporative Condenser Units',#7294,$,$); -#7299=IFCCLASSIFICATIONREFERENCE($,'23-33 43 15','Refrigeration Condenser Units',#7294,$,$); -#7300=IFCCLASSIFICATIONREFERENCE($,'23-33 43 15 11','Air Cooled Refrigeration Condenser Units',#7299,$,$); -#7301=IFCCLASSIFICATIONREFERENCE($,'23-33 43 15 13','Water Cooled Refrigeration Condenser Units',#7299,$,$); -#7302=IFCCLASSIFICATIONREFERENCE($,'23-33 43 17','Water Cooled Condenser Units',#7294,$,$); -#7303=IFCCLASSIFICATIONREFERENCE($,'23-33 43 17 11','Indoor Water Cooled Condenser Units',#7302,$,$); -#7304=IFCCLASSIFICATIONREFERENCE($,'23-33 45 00','HVAC Coolers',#6985,$,$); -#7305=IFCCLASSIFICATIONREFERENCE($,'23-33 45 11','HVAC Dry Coolers',#7304,$,$); -#7306=IFCCLASSIFICATIONREFERENCE($,'23-33 45 13','HVAC Evaporative Coolers',#7304,$,$); -#7307=IFCCLASSIFICATIONREFERENCE($,'23-33 47 00','Air Dryers',#6985,$,$); -#7308=IFCCLASSIFICATIONREFERENCE($,'23-33 47 11','Refrigerated Air Dryers',#7307,$,$); -#7309=IFCCLASSIFICATIONREFERENCE($,'23-33 47 13','Regenerative Desiccant Air Dryers',#7307,$,$); -#7310=IFCCLASSIFICATIONREFERENCE($,'23-33 49 00','HVAC Ductwork',#6985,$,$); -#7311=IFCCLASSIFICATIONREFERENCE($,'23-33 49 11','Ventilation Diffusers',#7310,$,$); -#7312=IFCCLASSIFICATIONREFERENCE($,'23-33 49 11 11','Ceiling Ventilation Diffusers',#7311,$,$); -#7313=IFCCLASSIFICATIONREFERENCE($,'23-33 49 11 11 11','Ceiling Linear Ventilation Diffusers',#7312,$,$); -#7314=IFCCLASSIFICATIONREFERENCE($,'23-33 49 11 13','Wall Ventilation Diffusers',#7311,$,$); -#7315=IFCCLASSIFICATIONREFERENCE($,'23-33 49 11 15','Floor Ventilation Diffusers',#7311,$,$); -#7316=IFCCLASSIFICATIONREFERENCE($,'23-33 49 13','Ventilation Ducts',#7310,$,$); -#7317=IFCCLASSIFICATIONREFERENCE($,'23-33 49 13 11','Round Ventilation Ducts',#7316,$,$); -#7318=IFCCLASSIFICATIONREFERENCE($,'23-33 49 13 11 11','Flexible Ventilation Ducts',#7317,$,$); -#7319=IFCCLASSIFICATIONREFERENCE($,'23-33 49 13 13','Square Ventilation Ducts',#7316,$,$); -#7320=IFCCLASSIFICATIONREFERENCE($,'23-33 49 15','Duct Access Panels',#7310,$,$); -#7321=IFCCLASSIFICATIONREFERENCE($,'23-33 49 17','Duct Insulation',#7310,$,$); -#7322=IFCCLASSIFICATIONREFERENCE($,'23-33 49 17 11','Duct Covering Insulation',#7321,$,$); -#7323=IFCCLASSIFICATIONREFERENCE($,'23-33 49 17 13','Duct Liner Insulation',#7321,$,$); -#7324=IFCCLASSIFICATIONREFERENCE($,'23-33 49 19','Ductwork Distribution Collectors',#7310,$,$); -#7325=IFCCLASSIFICATIONREFERENCE($,'23-33 49 21','Ductwork Expansion Vessels',#7310,$,$); -#7326=IFCCLASSIFICATIONREFERENCE($,'23-33 49 21 11','Air Outlets and Inlets',#7325,$,$); -#7327=IFCCLASSIFICATIONREFERENCE($,'23-33 49 21 13','Ductwork Guide Vanes',#7325,$,$); -#7328=IFCCLASSIFICATIONREFERENCE($,'23-33 49 21 15','Ductwork Air Mixers',#7325,$,$); -#7329=IFCCLASSIFICATIONREFERENCE($,'23-33 49 21 17','Ductwork Sound Attenuators',#7325,$,$); -#7330=IFCCLASSIFICATIONREFERENCE($,'23-33 49 23','Grilles',#7310,$,$); -#7331=IFCCLASSIFICATIONREFERENCE($,'23-33 49 23 11','Exhaust Air Grilles',#7330,$,$); -#7332=IFCCLASSIFICATIONREFERENCE($,'23-33 49 23 13','Return Air Grilles',#7330,$,$); -#7333=IFCCLASSIFICATIONREFERENCE($,'23-33 49 23 15','Supply Air Grilles',#7330,$,$); -#7334=IFCCLASSIFICATIONREFERENCE($,'23-33 49 23 17','Transfer Air Grilles',#7330,$,$); -#7335=IFCCLASSIFICATIONREFERENCE($,'23-33 49 25','Ventilation Registers',#7310,$,$); -#7336=IFCCLASSIFICATIONREFERENCE($,'23-33 49 25 11','Exhaust Air Ventilation Registers',#7335,$,$); -#7337=IFCCLASSIFICATIONREFERENCE($,'23-33 49 25 13','Return Air Ventilation Registers',#7335,$,$); -#7338=IFCCLASSIFICATIONREFERENCE($,'23-33 49 25 15','Supply Air Ventilation Registers',#7335,$,$); -#7339=IFCCLASSIFICATIONREFERENCE($,'23-33 49 27','Ventilators',#7310,$,$); -#7340=IFCCLASSIFICATIONREFERENCE($,'23-33 49 27 11','Gravity Ventilators',#7339,$,$); -#7341=IFCCLASSIFICATIONREFERENCE($,'23-33 49 27 13','Intake and Relief Ventilators',#7339,$,$); -#7342=IFCCLASSIFICATIONREFERENCE($,'23-33 49 27 15','Relief Ventilators',#7339,$,$); -#7343=IFCCLASSIFICATIONREFERENCE($,'23-33 49 27 17','Intake Ventilators',#7339,$,$); -#7344=IFCCLASSIFICATIONREFERENCE($,'23-33 49 29','Air Ductwork Accessories',#7310,$,$); -#7345=IFCCLASSIFICATIONREFERENCE($,'23-33 49 29 11','Access Fittings for Air Ductwork',#7344,$,$); -#7346=IFCCLASSIFICATIONREFERENCE($,'23-33 49 29 13','Couplings for Air Ductwork',#7344,$,$); -#7347=IFCCLASSIFICATIONREFERENCE($,'23-33 49 29 15','Hangers for Air Ductwork',#7344,$,$); -#7348=IFCCLASSIFICATIONREFERENCE($,'23-33 49 29 17','Supports for Air Ductwork',#7344,$,$); -#7349=IFCCLASSIFICATIONREFERENCE($,'23-33 49 29 19','Mechanical Fasteners for Air Ductwork',#7344,$,$); -#7350=IFCCLASSIFICATIONREFERENCE($,'23-33 51 00','HVAC Specialized Equipment',#6985,$,$); -#7351=IFCCLASSIFICATIONREFERENCE($,'23-33 51 11','Refrigerant Monitors',#7350,$,$); -#7352=IFCCLASSIFICATIONREFERENCE($,'23-33 51 13','Refrigerant Purge Units',#7350,$,$); -#7353=IFCCLASSIFICATIONREFERENCE($,'23-33 51 15','Ultraviolet Disinfection Lighting',#7350,$,$); -#7354=IFCCLASSIFICATIONREFERENCE($,'23-33 53 00','Solar Water Heating Equipment',#6985,$,$); -#7355=IFCCLASSIFICATIONREFERENCE($,'23-33 53 11','Solar Water Heating Packaged Units',#7354,$,$); -#7356=IFCCLASSIFICATIONREFERENCE($,'23-33 53 13','Solar Water Heating Collector Components',#7354,$,$); -#7357=IFCCLASSIFICATIONREFERENCE($,'23-33 53 13 11','Solar Water Heating Absorber Plates',#7356,$,$); -#7358=IFCCLASSIFICATIONREFERENCE($,'23-33 53 13 13','Solar Water Heating Absorber Tubing',#7356,$,$); -#7359=IFCCLASSIFICATIONREFERENCE($,'23-33 53 13 15','Solar Water Heating Coatings and Surface Treatment',#7356,$,$); -#7360=IFCCLASSIFICATIONREFERENCE($,'23-33 53 13 17','Solar Water Heating Collector Insulation',#7356,$,$); -#7361=IFCCLASSIFICATIONREFERENCE($,'23-33 53 13 19','Solar Water Heating Glazing',#7356,$,$); -#7362=IFCCLASSIFICATIONREFERENCE($,'23-33 53 13 21','Solar Water Heating Housing and Framing',#7356,$,$); -#7363=IFCCLASSIFICATIONREFERENCE($,'23-33 53 13 23','Solar Water Heating Reflectors',#7356,$,$); -#7364=IFCCLASSIFICATIONREFERENCE($,'23-33 53 15','Solar Water Heating Collector Units',#7354,$,$); -#7365=IFCCLASSIFICATIONREFERENCE($,'23-33 53 15 11','Solar Water Heating Flat Plate Collectors',#7364,$,$); -#7366=IFCCLASSIFICATIONREFERENCE($,'23-33 53 15 13','Solar Water Heating Concentrating Collectors',#7364,$,$); -#7367=IFCCLASSIFICATIONREFERENCE($,'23-33 53 15 15','Solar Water Heating Vacuum Tube Collectors',#7364,$,$); -#7368=IFCCLASSIFICATIONREFERENCE($,'23-33 55 00','Energy HVAC Recovery Equipment',#6985,$,$); -#7369=IFCCLASSIFICATIONREFERENCE($,'23-33 55 11','Heat Pipes',#7368,$,$); -#7370=IFCCLASSIFICATIONREFERENCE($,'23-33 55 13','Heat Wheels',#7368,$,$); -#7371=IFCCLASSIFICATIONREFERENCE($,'23-35 00 00','Electrical and Lighting Specific Products and Equipment',#1604,$,$); -#7372=IFCCLASSIFICATIONREFERENCE($,'23-35 11 00','Electrical Generators',#7371,$,$); -#7373=IFCCLASSIFICATIONREFERENCE($,'23-35 11 11','Single Unit Electrical Generators',#7372,$,$); -#7374=IFCCLASSIFICATIONREFERENCE($,'23-35 11 11 11','Engine Electrical Generators',#7373,$,$); -#7375=IFCCLASSIFICATIONREFERENCE($,'23-35 11 11 13','Motor Electrical Generators',#7373,$,$); -#7376=IFCCLASSIFICATIONREFERENCE($,'23-35 11 12','Single Unit Electrical Generator Engines',#7372,$,$); -#7377=IFCCLASSIFICATIONREFERENCE($,'23-35 11 12 11','Electrical Generation Diesel Engines',#7376,$,$); -#7378=IFCCLASSIFICATIONREFERENCE($,'23-35 11 12 13','Electrical Generation Gas Engines',#7376,$,$); -#7379=IFCCLASSIFICATIONREFERENCE($,'23-35 11 12 15','Electrical Generation Natural Gas Engines',#7376,$,$); -#7380=IFCCLASSIFICATIONREFERENCE($,'23-35 11 12 15 11','Electrical Generation Natural Gas Turbines',#7379,$,$); -#7381=IFCCLASSIFICATIONREFERENCE($,'23-35 11 12 17','Electrical Generation Steam Turbines',#7376,$,$); -#7382=IFCCLASSIFICATIONREFERENCE($,'23-35 11 13','Motor Generator Sets',#7372,$,$); -#7383=IFCCLASSIFICATIONREFERENCE($,'23-35 11 13 11','Alternating Current Frequency Converters',#7382,$,$); -#7384=IFCCLASSIFICATIONREFERENCE($,'23-35 11 13 13','Alternating Current Generator Sets',#7382,$,$); -#7385=IFCCLASSIFICATIONREFERENCE($,'23-35 11 13 15','Direct Current Generator Sets',#7382,$,$); -#7386=IFCCLASSIFICATIONREFERENCE($,'23-35 11 13 17','Multiple Frequency Electrical Generator Sets',#7382,$,$); -#7387=IFCCLASSIFICATIONREFERENCE($,'23-35 11 13 19','Multiple Voltage Electrical Generator Sets',#7382,$,$); -#7388=IFCCLASSIFICATIONREFERENCE($,'23-35 11 15','Engine Generator Sets',#7372,$,$); -#7389=IFCCLASSIFICATIONREFERENCE($,'23-35 11 15 11','Diesel Generator Sets',#7388,$,$); -#7390=IFCCLASSIFICATIONREFERENCE($,'23-35 11 15 13','Gas Generator Sets',#7388,$,$); -#7391=IFCCLASSIFICATIONREFERENCE($,'23-35 11 15 15','Natural Gas Generator Sets',#7388,$,$); -#7392=IFCCLASSIFICATIONREFERENCE($,'23-35 11 15 17','Steam Turbine Generator Sets',#7388,$,$); -#7393=IFCCLASSIFICATIONREFERENCE($,'23-35 11 15 19','Thermal Generator Sets',#7388,$,$); -#7394=IFCCLASSIFICATIONREFERENCE($,'23-35 11 15 21','Hydro Turbine Generator Sets',#7388,$,$); -#7395=IFCCLASSIFICATIONREFERENCE($,'23-35 11 15 23','Wind Generator Sets',#7388,$,$); -#7396=IFCCLASSIFICATIONREFERENCE($,'23-35 11 17','Photovoltaic Generators',#7372,$,$); -#7397=IFCCLASSIFICATIONREFERENCE($,'23-35 11 17 11','Photoelectric Cell',#7396,$,$); -#7398=IFCCLASSIFICATIONREFERENCE($,'23-35 11 17 12','Photoelectric Panel',#7396,$,$); -#7399=IFCCLASSIFICATIONREFERENCE($,'23-35 11 17 13','Photovoltaic Array',#7396,$,$); -#7400=IFCCLASSIFICATIONREFERENCE($,'23-35 11 17 15','Photovoltaic Collectors',#7396,$,$); -#7401=IFCCLASSIFICATIONREFERENCE($,'23-35 13 00','Transformers',#7371,$,$); -#7402=IFCCLASSIFICATIONREFERENCE($,'23-35 13 11','Current Transformers',#7401,$,$); -#7403=IFCCLASSIFICATIONREFERENCE($,'23-35 13 13','Instrument Transformers',#7401,$,$); -#7404=IFCCLASSIFICATIONREFERENCE($,'23-35 13 13 11','Current Instrument Transformers',#7403,$,$); -#7405=IFCCLASSIFICATIONREFERENCE($,'23-35 13 13 13','Pulse Instrument Transformers',#7403,$,$); -#7406=IFCCLASSIFICATIONREFERENCE($,'23-35 13 13 15','Voltage Instrument Transformers',#7403,$,$); -#7407=IFCCLASSIFICATIONREFERENCE($,'23-35 13 15','Electrical Network Transformers',#7401,$,$); -#7408=IFCCLASSIFICATIONREFERENCE($,'23-35 13 15 11','Electrical Network Isolation Transformers',#7407,$,$); -#7409=IFCCLASSIFICATIONREFERENCE($,'23-35 13 15 11 11','Electrical Network Dry Isolation Transformers',#7408,$,$); -#7410=IFCCLASSIFICATIONREFERENCE($,'23-35 13 15 11 13','Electrical Network Oil Filled Isolation Transformers',#7408,$,$); -#7411=IFCCLASSIFICATIONREFERENCE($,'23-35 13 15 13','Electrical Network Step Down Transformers',#7407,$,$); -#7412=IFCCLASSIFICATIONREFERENCE($,'23-35 13 15 13 11','Electrical Network Dry Step Down Transformers',#7411,$,$); -#7413=IFCCLASSIFICATIONREFERENCE($,'23-35 13 15 13 13','Electrical Network Oil Filled Step Down Transformers',#7411,$,$); -#7414=IFCCLASSIFICATIONREFERENCE($,'23-35 13 15 15','Electrical Network Step Up Transformers',#7407,$,$); -#7415=IFCCLASSIFICATIONREFERENCE($,'23-35 13 15 15 11','Electrical Network Dry Step Up Transformers',#7414,$,$); -#7416=IFCCLASSIFICATIONREFERENCE($,'23-35 13 15 15 13','Electrical Network Oil Filled Step Up Transformers',#7414,$,$); -#7417=IFCCLASSIFICATIONREFERENCE($,'23-35 13 17','Power Transformers',#7401,$,$); -#7418=IFCCLASSIFICATIONREFERENCE($,'23-35 13 17 11','Power Harmonic Mitigation Transformers',#7417,$,$); -#7419=IFCCLASSIFICATIONREFERENCE($,'23-35 13 17 11 11','Power Dry Harmonic Mitigation Transformers',#7418,$,$); -#7420=IFCCLASSIFICATIONREFERENCE($,'23-35 13 17 11 13','Power Oil Filled Harmonic Mitigation Transformers',#7418,$,$); -#7421=IFCCLASSIFICATIONREFERENCE($,'23-35 13 17 13','Power Isolation Transformers',#7417,$,$); -#7422=IFCCLASSIFICATIONREFERENCE($,'23-35 13 17 13 11','Power Dry Isolation Transformers',#7421,$,$); -#7423=IFCCLASSIFICATIONREFERENCE($,'23-35 13 17 13 13','Power Oil Filled Isolation Transformers',#7421,$,$); -#7424=IFCCLASSIFICATIONREFERENCE($,'23-35 13 17 15','Power Step Down Transformers',#7417,$,$); -#7425=IFCCLASSIFICATIONREFERENCE($,'23-35 13 17 15 11','Power Dry Step Down Transformers',#7424,$,$); -#7426=IFCCLASSIFICATIONREFERENCE($,'23-35 13 17 15 13','Power Oil Filled Step Down Transformers',#7424,$,$); -#7427=IFCCLASSIFICATIONREFERENCE($,'23-35 13 17 17','Power Step Up Transformers',#7417,$,$); -#7428=IFCCLASSIFICATIONREFERENCE($,'23-35 13 17 17 11','Power Dry Step Up Transformers',#7427,$,$); -#7429=IFCCLASSIFICATIONREFERENCE($,'23-35 13 17 17 13','Power Oil Filled Step Up Transformers',#7427,$,$); -#7430=IFCCLASSIFICATIONREFERENCE($,'23-35 13 19','Transformer Accessories',#7401,$,$); -#7431=IFCCLASSIFICATIONREFERENCE($,'23-35 13 19 11','Transformer Commutators',#7430,$,$); -#7432=IFCCLASSIFICATIONREFERENCE($,'23-35 13 19 13','Transformer Ballasts',#7430,$,$); -#7433=IFCCLASSIFICATIONREFERENCE($,'23-35 15 00','Electric Motors',#7371,$,$); -#7434=IFCCLASSIFICATIONREFERENCE($,'23-35 15 11','Alternating Current (AC) Motors',#7433,$,$); -#7435=IFCCLASSIFICATIONREFERENCE($,'23-35 15 11 11','Single Phase AC Motors',#7434,$,$); -#7436=IFCCLASSIFICATIONREFERENCE($,'23-35 15 11 11 11','Multi Speed Single Phase AC Motors',#7435,$,$); -#7437=IFCCLASSIFICATIONREFERENCE($,'23-35 15 11 11 13','Single Speed Single Phase AC Motors',#7435,$,$); -#7438=IFCCLASSIFICATIONREFERENCE($,'23-35 15 11 11 15','Synchronous Single Phase AC Motors',#7435,$,$); -#7439=IFCCLASSIFICATIONREFERENCE($,'23-35 15 11 13','Three Phase AC Motors',#7434,$,$); -#7440=IFCCLASSIFICATIONREFERENCE($,'23-35 15 11 13 11','Multi Speed Three Phase AC Motors',#7439,$,$); -#7441=IFCCLASSIFICATIONREFERENCE($,'23-35 15 11 13 13','Single Speed Three Phase AC Motors',#7439,$,$); -#7442=IFCCLASSIFICATIONREFERENCE($,'23-35 15 11 13 15','Synchronous Three Phase AC Motors',#7439,$,$); -#7443=IFCCLASSIFICATIONREFERENCE($,'23-35 15 13','Direct Current (DC) Motors',#7433,$,$); -#7444=IFCCLASSIFICATIONREFERENCE($,'23-35 15 13 11','Brushless DC Motors',#7443,$,$); -#7445=IFCCLASSIFICATIONREFERENCE($,'23-35 15 13 13','Compound Wound DC Motors',#7443,$,$); -#7446=IFCCLASSIFICATIONREFERENCE($,'23-35 15 13 15','Coreless DC Motors',#7443,$,$); -#7447=IFCCLASSIFICATIONREFERENCE($,'23-35 15 13 17','Limited Angle Torque DC Motors',#7443,$,$); -#7448=IFCCLASSIFICATIONREFERENCE($,'23-35 15 13 19','Linear DC Motors',#7443,$,$); -#7449=IFCCLASSIFICATIONREFERENCE($,'23-35 15 13 21','Permanent Magnetic DC Motors',#7443,$,$); -#7450=IFCCLASSIFICATIONREFERENCE($,'23-35 15 13 23','Series Wound DC Motors',#7443,$,$); -#7451=IFCCLASSIFICATIONREFERENCE($,'23-35 15 13 25','Shunt Wound DC Motors',#7443,$,$); -#7452=IFCCLASSIFICATIONREFERENCE($,'23-35 15 13 27','Step DC Motors',#7443,$,$); -#7453=IFCCLASSIFICATIONREFERENCE($,'23-35 15 15','DC Servo Motors',#7433,$,$); -#7454=IFCCLASSIFICATIONREFERENCE($,'23-35 15 17','Dynamotors',#7433,$,$); -#7455=IFCCLASSIFICATIONREFERENCE($,'23-35 15 19','Hydraulic Driven Motors',#7433,$,$); -#7456=IFCCLASSIFICATIONREFERENCE($,'23-35 15 21','Pneumatic Driven Motors',#7433,$,$); -#7457=IFCCLASSIFICATIONREFERENCE($,'23-35 15 23','Steam Driven Motors',#7433,$,$); -#7458=IFCCLASSIFICATIONREFERENCE($,'23-35 17 00','Variable Speed Drives',#7371,$,$); -#7459=IFCCLASSIFICATIONREFERENCE($,'23-35 17 11','Direct Current Electronic Speed Controller Drives',#7458,$,$); -#7460=IFCCLASSIFICATIONREFERENCE($,'23-35 17 13','Slip Controlled Drives',#7458,$,$); -#7461=IFCCLASSIFICATIONREFERENCE($,'23-35 17 15','Variable Frequency Drives',#7458,$,$); -#7462=IFCCLASSIFICATIONREFERENCE($,'23-35 17 15 11','Pulse Width Variable Frequency Drives',#7461,$,$); -#7463=IFCCLASSIFICATIONREFERENCE($,'23-35 17 15 13','Current Source Input Variable Frequency Drives',#7461,$,$); -#7464=IFCCLASSIFICATIONREFERENCE($,'23-35 17 15 15','Variable Voltage Input Variable Frequency Drives',#7461,$,$); -#7465=IFCCLASSIFICATIONREFERENCE($,'23-35 19 00','Batteries',#7371,$,$); -#7466=IFCCLASSIFICATIONREFERENCE($,'23-35 19 11','Battery Racks',#7465,$,$); -#7467=IFCCLASSIFICATIONREFERENCE($,'23-35 19 13','Non Rechargeable Batteries',#7465,$,$); -#7468=IFCCLASSIFICATIONREFERENCE($,'23-35 19 13 11','Alkaline Batteries',#7467,$,$); -#7469=IFCCLASSIFICATIONREFERENCE($,'23-35 19 13 13','Dry Cell Batteries',#7467,$,$); -#7470=IFCCLASSIFICATIONREFERENCE($,'23-35 19 13 15','Lithium Batteries',#7467,$,$); -#7471=IFCCLASSIFICATIONREFERENCE($,'23-35 19 13 17','Silver Oxide Batteries',#7467,$,$); -#7472=IFCCLASSIFICATIONREFERENCE($,'23-35 19 13 19','Zinc Air Batteries',#7467,$,$); -#7473=IFCCLASSIFICATIONREFERENCE($,'23-35 19 13 21','Zinc Coal Batteries',#7467,$,$); -#7474=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15','Rechargeable Batteries',#7465,$,$); -#7475=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15 11','Alkaline Batteries',#7474,$,$); -#7476=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15 13','Lead Acid Batteries',#7474,$,$); -#7477=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15 13 11','Sealed Lead Acid Batteries',#7476,$,$); -#7478=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15 13 13','Wet Cell Lead Acid Batteries',#7476,$,$); -#7479=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15 15','Lithium Batteries',#7474,$,$); -#7480=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15 17','Manganese Batteries',#7474,$,$); -#7481=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15 19','Mercuric Oxide Batteries',#7474,$,$); -#7482=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15 21','Nickel Cadmium Batteries',#7474,$,$); -#7483=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15 23','Nickel Hydrogen Batteries',#7474,$,$); -#7484=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15 25','Nickel Iron Batteries',#7474,$,$); -#7485=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15 27','Nickel Metal Hydride Batteries',#7474,$,$); -#7486=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15 29','Nickel Sodium Chloride Batteries',#7474,$,$); -#7487=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15 31','Silver Oxide Batteries',#7474,$,$); -#7488=IFCCLASSIFICATIONREFERENCE($,'23-35 21 00','Battery Chargers',#7371,$,$); -#7489=IFCCLASSIFICATIONREFERENCE($,'23-35 23 00','Power Conditioning Equipment',#7371,$,$); -#7490=IFCCLASSIFICATIONREFERENCE($,'23-35 23 11','Harmonic Control Devices',#7489,$,$); -#7491=IFCCLASSIFICATIONREFERENCE($,'23-35 23 11 11','Electric Interference Suppressor Filters',#7490,$,$); -#7492=IFCCLASSIFICATIONREFERENCE($,'23-35 23 11 13','Harmonic Filters',#7490,$,$); -#7493=IFCCLASSIFICATIONREFERENCE($,'23-35 23 13','Power Converters',#7489,$,$); -#7494=IFCCLASSIFICATIONREFERENCE($,'23-35 23 13 11','Rotary Converters',#7493,$,$); -#7495=IFCCLASSIFICATIONREFERENCE($,'23-35 23 15','Static Power Converters',#7489,$,$); -#7496=IFCCLASSIFICATIONREFERENCE($,'23-35 23 15 11','Static Rectifiers',#7495,$,$); -#7497=IFCCLASSIFICATIONREFERENCE($,'23-35 23 15 13','Ondulators',#7495,$,$); -#7498=IFCCLASSIFICATIONREFERENCE($,'23-35 23 15 15','Combined Converter Sets',#7495,$,$); -#7499=IFCCLASSIFICATIONREFERENCE($,'23-35 23 15 17','Direct Current (DC) Drive Controllers',#7495,$,$); -#7500=IFCCLASSIFICATIONREFERENCE($,'23-35 23 15 19','Slip Controllers',#7495,$,$); -#7501=IFCCLASSIFICATIONREFERENCE($,'23-35 23 15 21','Static Frequency Converters',#7495,$,$); -#7502=IFCCLASSIFICATIONREFERENCE($,'23-35 23 15 23','Static Uninterruptible Power Supplies',#7495,$,$); -#7503=IFCCLASSIFICATIONREFERENCE($,'23-35 23 15 25','Variable Frequency Controllers',#7495,$,$); -#7504=IFCCLASSIFICATIONREFERENCE($,'23-35 23 15 27','Frequency Changers',#7495,$,$); -#7505=IFCCLASSIFICATIONREFERENCE($,'23-35 23 15 29','Rotary Uninterruptible Power Units',#7495,$,$); -#7506=IFCCLASSIFICATIONREFERENCE($,'23-35 23 17','Power Inverters',#7489,$,$); -#7507=IFCCLASSIFICATIONREFERENCE($,'23-35 23 17 11','Commutator Inverters',#7506,$,$); -#7508=IFCCLASSIFICATIONREFERENCE($,'23-35 23 17 13','Solid State Inverters',#7506,$,$); -#7509=IFCCLASSIFICATIONREFERENCE($,'23-35 23 19','Powerfactor Correction Devices',#7489,$,$); -#7510=IFCCLASSIFICATIONREFERENCE($,'23-35 23 19 11','Capacitive and Inductive Power Correction Devices',#7509,$,$); -#7511=IFCCLASSIFICATIONREFERENCE($,'23-35 23 19 13','Capacitive Power Correction Devices',#7509,$,$); -#7512=IFCCLASSIFICATIONREFERENCE($,'23-35 23 19 15','Inductive Power Correction Devices',#7509,$,$); -#7513=IFCCLASSIFICATIONREFERENCE($,'23-35 23 19 17','Capacitors',#7509,$,$); -#7514=IFCCLASSIFICATIONREFERENCE($,'23-35 23 19 19','Power Factor Controls (Cosines Phi)',#7509,$,$); -#7515=IFCCLASSIFICATIONREFERENCE($,'23-35 23 21','Uninterrupted Power Supply (UPS) Units',#7489,$,$); -#7516=IFCCLASSIFICATIONREFERENCE($,'23-35 23 21 11','Uninterruptible Power Supply Component Systems',#7515,$,$); -#7517=IFCCLASSIFICATIONREFERENCE($,'23-35 23 21 13','Uninterruptible Power Supply Packaged Units',#7515,$,$); -#7518=IFCCLASSIFICATIONREFERENCE($,'23-35 25 00','Electrical Instrumentation and Controls',#7371,$,$); -#7519=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11','Electrical Meters',#7518,$,$); -#7520=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 11','Power Meters',#7519,$,$); -#7521=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 13','Voltage Meters',#7519,$,$); -#7522=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 15','Resistance Meters',#7519,$,$); -#7523=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 17','Frequency Meters',#7519,$,$); -#7524=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 19','Multi Meters',#7519,$,$); -#7525=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 21','Current Meters',#7519,$,$); -#7526=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 23','Amp Hour Meters',#7519,$,$); -#7527=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 25','Power Factor Meters',#7519,$,$); -#7528=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 27','Kilowatt Hour Meters',#7519,$,$); -#7529=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 27 11','Electromechanical Remote Kilowatt Hour Meters',#7528,$,$); -#7530=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 27 13','Electromechancial Kilowatt Hour Meters',#7528,$,$); -#7531=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 27 15','Solid State Remote Kilowatt Hour Meters',#7528,$,$); -#7532=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 27 17','Solid State Kilowatt Hour Meters',#7528,$,$); -#7533=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 29','Multiple Tariff Meters',#7519,$,$); -#7534=IFCCLASSIFICATIONREFERENCE($,'23-35 25 13','Electrical Energy Recording Devices',#7518,$,$); -#7535=IFCCLASSIFICATIONREFERENCE($,'23-35 25 13 11','Watt Hour Recorders',#7534,$,$); -#7536=IFCCLASSIFICATIONREFERENCE($,'23-35 25 15','Electrical Network Protection Modules',#7518,$,$); -#7537=IFCCLASSIFICATIONREFERENCE($,'23-35 25 17','Electrical Power Protection Modules',#7518,$,$); -#7538=IFCCLASSIFICATIONREFERENCE($,'23-35 25 19','Motor Starters',#7518,$,$); -#7539=IFCCLASSIFICATIONREFERENCE($,'23-35 25 21','Programmable Logic Controllers',#7518,$,$); -#7540=IFCCLASSIFICATIONREFERENCE($,'23-35 25 23','Electrical Control Panels',#7518,$,$); -#7541=IFCCLASSIFICATIONREFERENCE($,'23-35 25 25','Electrical Line Supervisor Sets',#7518,$,$); -#7542=IFCCLASSIFICATIONREFERENCE($,'23-35 27 00','Electrical Terminals',#7371,$,$); -#7543=IFCCLASSIFICATIONREFERENCE($,'23-35 27 11','Electrical Receptacles',#7542,$,$); -#7544=IFCCLASSIFICATIONREFERENCE($,'23-35 27 11 11','Electrical Receptacle Terminal Units',#7543,$,$); -#7545=IFCCLASSIFICATIONREFERENCE($,'23-35 27 11 13','Ground Fault Receptacles',#7543,$,$); -#7546=IFCCLASSIFICATIONREFERENCE($,'23-35 27 11 15','Electrical Extension Cords',#7543,$,$); -#7547=IFCCLASSIFICATIONREFERENCE($,'23-35 27 11 17','Electrical Receptacle Accessories',#7543,$,$); -#7548=IFCCLASSIFICATIONREFERENCE($,'23-35 27 11 17 11','Electrical Telltale Lamps',#7547,$,$); -#7549=IFCCLASSIFICATIONREFERENCE($,'23-35 27 11 17 13','Electrical Receptacle Protectors',#7547,$,$); -#7550=IFCCLASSIFICATIONREFERENCE($,'23-35 27 11 17 15','Electrical Receptacle Adapters',#7547,$,$); -#7551=IFCCLASSIFICATIONREFERENCE($,'23-35 27 13','Electrical Plug Connectors',#7542,$,$); -#7552=IFCCLASSIFICATIONREFERENCE($,'23-35 29 00','Circuit Breakers',#7371,$,$); -#7553=IFCCLASSIFICATIONREFERENCE($,'23-35 29 11','Air Circuit Breakers',#7552,$,$); -#7554=IFCCLASSIFICATIONREFERENCE($,'23-35 29 11 11','Network Distribution Air Circuit Breakers',#7553,$,$); -#7555=IFCCLASSIFICATIONREFERENCE($,'23-35 29 11 13','Power Distribution Air Circuit Breakers',#7553,$,$); -#7556=IFCCLASSIFICATIONREFERENCE($,'23-35 29 13','Gas Circuit Breakers',#7552,$,$); -#7557=IFCCLASSIFICATIONREFERENCE($,'23-35 29 13 11','Network Distribution Gas Circuit Breakers',#7556,$,$); -#7558=IFCCLASSIFICATIONREFERENCE($,'23-35 29 13 13','Power Distribution Gas Circuit Breakers',#7556,$,$); -#7559=IFCCLASSIFICATIONREFERENCE($,'23-35 29 15','Ground Fault Circuit Breakers',#7552,$,$); -#7560=IFCCLASSIFICATIONREFERENCE($,'23-35 29 17','Molded Case Circuit Breakers',#7552,$,$); -#7561=IFCCLASSIFICATIONREFERENCE($,'23-35 29 17 11','Shunt Molded Case Circuit Breakers',#7560,$,$); -#7562=IFCCLASSIFICATIONREFERENCE($,'23-35 29 19','Oil Circuit Breakers',#7552,$,$); -#7563=IFCCLASSIFICATIONREFERENCE($,'23-35 29 19 11','Network Distribution Oil Circuit Breakers',#7562,$,$); -#7564=IFCCLASSIFICATIONREFERENCE($,'23-35 29 19 13','Power Distribution Oil Circuit Breakers',#7562,$,$); -#7565=IFCCLASSIFICATIONREFERENCE($,'23-35 29 21','Vacuum Circuit Breakers',#7552,$,$); -#7566=IFCCLASSIFICATIONREFERENCE($,'23-35 29 21 11','Network Distribution Vacuum Circuit Breakers',#7565,$,$); -#7567=IFCCLASSIFICATIONREFERENCE($,'23-35 29 21 13','Power Distribution Vacuum Circuit Breakers',#7565,$,$); -#7568=IFCCLASSIFICATIONREFERENCE($,'23-35 29 23','Ground Fault Circuit Interrupters',#7552,$,$); -#7569=IFCCLASSIFICATIONREFERENCE($,'23-35 29 25','Network Protectors',#7552,$,$); -#7570=IFCCLASSIFICATIONREFERENCE($,'23-35 29 27','Electrical Disconnects',#7552,$,$); -#7571=IFCCLASSIFICATIONREFERENCE($,'23-35 29 27 11','Air Disconnects',#7570,$,$); -#7572=IFCCLASSIFICATIONREFERENCE($,'23-35 29 27 13','Vacuum Disconnects',#7570,$,$); -#7573=IFCCLASSIFICATIONREFERENCE($,'23-35 29 27 15','Gas Disconnects',#7570,$,$); -#7574=IFCCLASSIFICATIONREFERENCE($,'23-35 29 29','Fuses',#7552,$,$); -#7575=IFCCLASSIFICATIONREFERENCE($,'23-35 29 29 11','Fuse Panels',#7574,$,$); -#7576=IFCCLASSIFICATIONREFERENCE($,'23-35 29 29 13','Fuse Holders',#7574,$,$); -#7577=IFCCLASSIFICATIONREFERENCE($,'23-35 31 00','Electrical Power Distribution Devices',#7371,$,$); -#7578=IFCCLASSIFICATIONREFERENCE($,'23-35 31 11','Power Supply Devices',#7577,$,$); -#7579=IFCCLASSIFICATIONREFERENCE($,'23-35 31 13','Distribution Panel Boards',#7577,$,$); -#7580=IFCCLASSIFICATIONREFERENCE($,'23-35 31 15','Electrical Distribution Control Panels',#7577,$,$); -#7581=IFCCLASSIFICATIONREFERENCE($,'23-35 31 17','Electrical Panel Boards',#7577,$,$); -#7582=IFCCLASSIFICATIONREFERENCE($,'23-35 31 19','Electrical Panel Meter Sockets',#7577,$,$); -#7583=IFCCLASSIFICATIONREFERENCE($,'23-35 31 21','Load Centers',#7577,$,$); -#7584=IFCCLASSIFICATIONREFERENCE($,'23-35 31 23','Motor Control Centers',#7577,$,$); -#7585=IFCCLASSIFICATIONREFERENCE($,'23-35 31 25','Power Control and Monitoring Assemblies',#7577,$,$); -#7586=IFCCLASSIFICATIONREFERENCE($,'23-35 31 27','Power Distribution Units',#7577,$,$); -#7587=IFCCLASSIFICATIONREFERENCE($,'23-35 31 27 11','Multiple Section Power Distribution Units',#7586,$,$); -#7588=IFCCLASSIFICATIONREFERENCE($,'23-35 31 27 13','Stand Alone Power Distribution Units',#7586,$,$); -#7589=IFCCLASSIFICATIONREFERENCE($,'23-35 31 29','Switchboards',#7577,$,$); -#7590=IFCCLASSIFICATIONREFERENCE($,'23-35 31 29 11','Distribution Switchboards',#7589,$,$); -#7591=IFCCLASSIFICATIONREFERENCE($,'23-35 31 29 13','Paralleling Switchboards',#7589,$,$); -#7592=IFCCLASSIFICATIONREFERENCE($,'23-35 31 31','Switchgear',#7577,$,$); -#7593=IFCCLASSIFICATIONREFERENCE($,'23-35 31 31 11','Distribution Switchgear',#7592,$,$); -#7594=IFCCLASSIFICATIONREFERENCE($,'23-35 31 31 11 11','Electronic Controlled Distribution Switchgear',#7593,$,$); -#7595=IFCCLASSIFICATIONREFERENCE($,'23-35 31 31 11 13','Mechanically Controlled Distribution Switchgear',#7593,$,$); -#7596=IFCCLASSIFICATIONREFERENCE($,'23-35 31 31 11 15','Remote Controlled Distribution Switchgear',#7593,$,$); -#7597=IFCCLASSIFICATIONREFERENCE($,'23-35 31 31 11 17','Time Controlled Distribution Switchgear',#7593,$,$); -#7598=IFCCLASSIFICATIONREFERENCE($,'23-35 31 31 13','Paralleling Switchgear',#7592,$,$); -#7599=IFCCLASSIFICATIONREFERENCE($,'23-35 31 31 13 11','Electronic Controlled Paralleling Switchgear',#7598,$,$); -#7600=IFCCLASSIFICATIONREFERENCE($,'23-35 31 31 13 13','Mechanically Controlled Paralleling Switchgear',#7598,$,$); -#7601=IFCCLASSIFICATIONREFERENCE($,'23-35 31 31 13 15','Remote Controlled Paralleling Switchgear',#7598,$,$); -#7602=IFCCLASSIFICATIONREFERENCE($,'23-35 31 31 13 17','Time Controlled Paralleling Switchgear',#7598,$,$); -#7603=IFCCLASSIFICATIONREFERENCE($,'23-35 31 33','Electrical Busbars',#7577,$,$); -#7604=IFCCLASSIFICATIONREFERENCE($,'23-35 31 33 11','Aluminum Electrical Busbars',#7603,$,$); -#7605=IFCCLASSIFICATIONREFERENCE($,'23-35 31 33 13','Copper Electrical Busbars',#7603,$,$); -#7606=IFCCLASSIFICATIONREFERENCE($,'23-35 31 35','Electrical Feeders',#7577,$,$); -#7607=IFCCLASSIFICATIONREFERENCE($,'23-35 33 00','Electrical Ducting Wireways Components',#7371,$,$); -#7608=IFCCLASSIFICATIONREFERENCE($,'23-35 33 11','Electrical Service Penetrations',#7607,$,$); -#7609=IFCCLASSIFICATIONREFERENCE($,'23-35 33 13','Electrical Conductor Components',#7607,$,$); -#7610=IFCCLASSIFICATIONREFERENCE($,'23-35 33 13 11','Electrical Conductor Rails',#7609,$,$); -#7611=IFCCLASSIFICATIONREFERENCE($,'23-35 33 13 13','Electrical Conductor Couplings',#7609,$,$); -#7612=IFCCLASSIFICATIONREFERENCE($,'23-35 33 13 15','Electrical Conductor Insulation',#7609,$,$); -#7613=IFCCLASSIFICATIONREFERENCE($,'23-35 33 13 17','Electrical Support Wires',#7609,$,$); -#7614=IFCCLASSIFICATIONREFERENCE($,'23-35 33 13 19','Conductor Mechanical Fasteners',#7609,$,$); -#7615=IFCCLASSIFICATIONREFERENCE($,'23-35 33 15','Electrical Junction Boxes',#7607,$,$); -#7616=IFCCLASSIFICATIONREFERENCE($,'23-35 33 15 11','Electrical Ceiling Junction Boxes',#7615,$,$); -#7617=IFCCLASSIFICATIONREFERENCE($,'23-35 33 15 13','Electrical Wall Junction Boxes',#7615,$,$); -#7618=IFCCLASSIFICATIONREFERENCE($,'23-35 33 17','Electrical Conduits',#7607,$,$); -#7619=IFCCLASSIFICATIONREFERENCE($,'23-35 33 17 11','Electrical Cable Reels',#7618,$,$); -#7620=IFCCLASSIFICATIONREFERENCE($,'23-35 33 17 13','Mechanical Fasteners for Conduits',#7618,$,$); -#7621=IFCCLASSIFICATIONREFERENCE($,'23-35 33 17 15','Mechanical Fasteners for Trunking',#7618,$,$); -#7622=IFCCLASSIFICATIONREFERENCE($,'23-35 33 19','Electrical Cable Trays',#7607,$,$); -#7623=IFCCLASSIFICATIONREFERENCE($,'23-35 33 21','Electrical Bus Ducts',#7607,$,$); -#7624=IFCCLASSIFICATIONREFERENCE($,'23-35 33 21 11','Aluminum Electrical Bus Ducts',#7623,$,$); -#7625=IFCCLASSIFICATIONREFERENCE($,'23-35 33 21 13','Copper Electrical Bus Ducts',#7623,$,$); -#7626=IFCCLASSIFICATIONREFERENCE($,'23-35 33 23','Electrical Racks',#7607,$,$); -#7627=IFCCLASSIFICATIONREFERENCE($,'23-35 33 23 11','Horizontal Electrical Racks',#7626,$,$); -#7628=IFCCLASSIFICATIONREFERENCE($,'23-35 33 23 13','Vertical Electrical Racks',#7626,$,$); -#7629=IFCCLASSIFICATIONREFERENCE($,'23-35 33 25','Electrical Wireways',#7607,$,$); -#7630=IFCCLASSIFICATIONREFERENCE($,'23-35 33 25 11','Underfloor Electrical Wireways',#7629,$,$); -#7631=IFCCLASSIFICATIONREFERENCE($,'23-35 33 25 13','Vertical Electrical Wire Raceways',#7629,$,$); -#7632=IFCCLASSIFICATIONREFERENCE($,'23-35 33 25 15','Horizontal Electrical Wire Raceways',#7629,$,$); -#7633=IFCCLASSIFICATIONREFERENCE($,'23-35 33 25 17','Ceiling Grid Electrical Systems',#7629,$,$); -#7634=IFCCLASSIFICATIONREFERENCE($,'23-35 33 25 17 11','Ceiling Grid Electrical Wire Tracks',#7633,$,$); -#7635=IFCCLASSIFICATIONREFERENCE($,'23-35 33 25 17 13','Ceiling Grid Electrical Wire Track Connectors',#7633,$,$); -#7636=IFCCLASSIFICATIONREFERENCE($,'23-35 35 00','Electrical Contactors',#7371,$,$); -#7637=IFCCLASSIFICATIONREFERENCE($,'23-35 37 00','Electrical Switches',#7371,$,$); -#7638=IFCCLASSIFICATIONREFERENCE($,'23-35 37 11','Automatic Transfer Switches',#7637,$,$); -#7639=IFCCLASSIFICATIONREFERENCE($,'23-35 37 11 11','Normal Power Seeking Automatic Transfer Switches',#7638,$,$); -#7640=IFCCLASSIFICATIONREFERENCE($,'23-35 37 11 13','Power Seeking Automatic Transfer Switches',#7638,$,$); -#7641=IFCCLASSIFICATIONREFERENCE($,'23-35 37 13','Manual Transfer Switches',#7637,$,$); -#7642=IFCCLASSIFICATIONREFERENCE($,'23-35 37 15','Barrel Switches',#7637,$,$); -#7643=IFCCLASSIFICATIONREFERENCE($,'23-35 37 15 11','Barrel Key Switches',#7642,$,$); -#7644=IFCCLASSIFICATIONREFERENCE($,'23-35 37 17','Dimmer Control Switches',#7637,$,$); -#7645=IFCCLASSIFICATIONREFERENCE($,'23-35 37 17 11','Lighting Dimmer Rheostats',#7644,$,$); -#7646=IFCCLASSIFICATIONREFERENCE($,'23-35 37 17 12','Ganged Lighting Dimmers',#7644,$,$); -#7647=IFCCLASSIFICATIONREFERENCE($,'23-35 37 17 13','Dimmers',#7644,$,$); -#7648=IFCCLASSIFICATIONREFERENCE($,'23-35 37 19','Disconnect Switches',#7637,$,$); -#7649=IFCCLASSIFICATIONREFERENCE($,'23-35 37 19 11','Fused Disconnect Switches',#7648,$,$); -#7650=IFCCLASSIFICATIONREFERENCE($,'23-35 37 19 13','Non Fused Disconnect Switches',#7648,$,$); -#7651=IFCCLASSIFICATIONREFERENCE($,'23-35 37 21','Drum Switches',#7637,$,$); -#7652=IFCCLASSIFICATIONREFERENCE($,'23-35 37 23','Flow Switches',#7637,$,$); -#7653=IFCCLASSIFICATIONREFERENCE($,'23-35 37 25','Key Lock Switches',#7637,$,$); -#7654=IFCCLASSIFICATIONREFERENCE($,'23-35 37 27','Limit Switches',#7637,$,$); -#7655=IFCCLASSIFICATIONREFERENCE($,'23-35 37 27 11','Level Switches',#7654,$,$); -#7656=IFCCLASSIFICATIONREFERENCE($,'23-35 37 27 13','Reed Switches',#7654,$,$); -#7657=IFCCLASSIFICATIONREFERENCE($,'23-35 37 29','Modular Wiring System Switches',#7637,$,$); -#7658=IFCCLASSIFICATIONREFERENCE($,'23-35 37 31','Photocell Switches',#7637,$,$); -#7659=IFCCLASSIFICATIONREFERENCE($,'23-35 37 33','Pressure Switches',#7637,$,$); -#7660=IFCCLASSIFICATIONREFERENCE($,'23-35 37 33 11','Differential Pressure Switches',#7659,$,$); -#7661=IFCCLASSIFICATIONREFERENCE($,'23-35 37 35','Rocker Switches',#7637,$,$); -#7662=IFCCLASSIFICATIONREFERENCE($,'23-35 37 35 11','Mercury Switches',#7661,$,$); -#7663=IFCCLASSIFICATIONREFERENCE($,'23-35 37 37','Time Switches',#7637,$,$); -#7664=IFCCLASSIFICATIONREFERENCE($,'23-35 37 39','Foot Switches',#7637,$,$); -#7665=IFCCLASSIFICATIONREFERENCE($,'23-35 37 41','Joysticks',#7637,$,$); -#7666=IFCCLASSIFICATIONREFERENCE($,'23-35 37 43','Programmable Logic Control Switches',#7637,$,$); -#7667=IFCCLASSIFICATIONREFERENCE($,'23-35 37 45','Proximity Switches',#7637,$,$); -#7668=IFCCLASSIFICATIONREFERENCE($,'23-35 37 47','Pull Chain Switches',#7637,$,$); -#7669=IFCCLASSIFICATIONREFERENCE($,'23-35 37 49','Push Button Switches',#7637,$,$); -#7670=IFCCLASSIFICATIONREFERENCE($,'23-35 37 51','Radio Frequency Switches',#7637,$,$); -#7671=IFCCLASSIFICATIONREFERENCE($,'23-35 37 53','Rotary Switches',#7637,$,$); -#7672=IFCCLASSIFICATIONREFERENCE($,'23-35 37 55','Slide Switches',#7637,$,$); -#7673=IFCCLASSIFICATIONREFERENCE($,'23-35 37 57','Snap Switches',#7637,$,$); -#7674=IFCCLASSIFICATIONREFERENCE($,'23-35 37 59','Speed Switches',#7637,$,$); -#7675=IFCCLASSIFICATIONREFERENCE($,'23-35 37 61','Tamper Switches',#7637,$,$); -#7676=IFCCLASSIFICATIONREFERENCE($,'23-35 37 63','Temperature Switches',#7637,$,$); -#7677=IFCCLASSIFICATIONREFERENCE($,'23-35 37 65','Vacuum Switches',#7637,$,$); -#7678=IFCCLASSIFICATIONREFERENCE($,'23-35 39 00','Electric Power Protection Devices',#7371,$,$); -#7679=IFCCLASSIFICATIONREFERENCE($,'23-35 39 11','Electrical Grounding Device',#7678,$,$); -#7680=IFCCLASSIFICATIONREFERENCE($,'23-35 39 13','Earth Connection Electrodes',#7678,$,$); -#7681=IFCCLASSIFICATIONREFERENCE($,'23-35 39 13 11','Electrical Ground Plates',#7680,$,$); -#7682=IFCCLASSIFICATIONREFERENCE($,'23-35 39 13 13','Electrical Ground Rods',#7680,$,$); -#7683=IFCCLASSIFICATIONREFERENCE($,'23-35 39 15','Lightning Protection',#7678,$,$); -#7684=IFCCLASSIFICATIONREFERENCE($,'23-35 39 15 11','Lightning Arresters',#7683,$,$); -#7685=IFCCLASSIFICATIONREFERENCE($,'23-35 39 15 13','Lightning Rods',#7683,$,$); -#7686=IFCCLASSIFICATIONREFERENCE($,'23-35 39 17','Surge Protection Devices',#7678,$,$); -#7687=IFCCLASSIFICATIONREFERENCE($,'23-35 41 00','Electrical Isolation Equipment',#7371,$,$); -#7688=IFCCLASSIFICATIONREFERENCE($,'23-35 41 11','Electronic Chokes',#7687,$,$); -#7689=IFCCLASSIFICATIONREFERENCE($,'23-35 41 13','Signal Converters',#7687,$,$); -#7690=IFCCLASSIFICATIONREFERENCE($,'23-35 43 00','Electrical Relays',#7371,$,$); -#7691=IFCCLASSIFICATIONREFERENCE($,'23-35 43 11','Auxiliary Protective Relays',#7690,$,$); -#7692=IFCCLASSIFICATIONREFERENCE($,'23-35 43 13','Control Relays',#7690,$,$); -#7693=IFCCLASSIFICATIONREFERENCE($,'23-35 43 15','Current Differential Relays',#7690,$,$); -#7694=IFCCLASSIFICATIONREFERENCE($,'23-35 43 15 11','Current Differential Solid State Relays',#7693,$,$); -#7695=IFCCLASSIFICATIONREFERENCE($,'23-35 43 17','General Purpose Relays',#7690,$,$); -#7696=IFCCLASSIFICATIONREFERENCE($,'23-35 43 19','Ground Fault Relays',#7690,$,$); -#7697=IFCCLASSIFICATIONREFERENCE($,'23-35 43 19 11','Ground Fault Solid State Relays',#7696,$,$); -#7698=IFCCLASSIFICATIONREFERENCE($,'23-35 43 21','Load Shedding Relays',#7690,$,$); -#7699=IFCCLASSIFICATIONREFERENCE($,'23-35 43 23','Lockout Relays',#7690,$,$); -#7700=IFCCLASSIFICATIONREFERENCE($,'23-35 43 23 11','Automatic Reset Lockout Relays',#7699,$,$); -#7701=IFCCLASSIFICATIONREFERENCE($,'23-35 43 23 13','Manual Reset Lockout Relays',#7699,$,$); -#7702=IFCCLASSIFICATIONREFERENCE($,'23-35 43 25','Mercury Relays',#7690,$,$); -#7703=IFCCLASSIFICATIONREFERENCE($,'23-35 43 27','Over Current Relays',#7690,$,$); -#7704=IFCCLASSIFICATIONREFERENCE($,'23-35 43 27 11','Overcurrent Directional, Induction Disc Relays',#7703,$,$); -#7705=IFCCLASSIFICATIONREFERENCE($,'23-35 43 27 13','Over Current Induction Disc Relays',#7703,$,$); -#7706=IFCCLASSIFICATIONREFERENCE($,'23-35 43 27 15','Over Current Thermal Relays',#7703,$,$); -#7707=IFCCLASSIFICATIONREFERENCE($,'23-35 43 27 17','Over Current Solid State Relays',#7703,$,$); -#7708=IFCCLASSIFICATIONREFERENCE($,'23-35 43 29','Overload Relays',#7690,$,$); -#7709=IFCCLASSIFICATIONREFERENCE($,'23-35 43 29 11','Overload Solid State Relays',#7708,$,$); -#7710=IFCCLASSIFICATIONREFERENCE($,'23-35 43 31','Phase Failure Relays',#7690,$,$); -#7711=IFCCLASSIFICATIONREFERENCE($,'23-35 43 31 11','Phase Failure Solid State Relays',#7710,$,$); -#7712=IFCCLASSIFICATIONREFERENCE($,'23-35 43 33','Power Relays',#7690,$,$); -#7713=IFCCLASSIFICATIONREFERENCE($,'23-35 43 35','Time Relays',#7690,$,$); -#7714=IFCCLASSIFICATIONREFERENCE($,'23-35 43 35 11','Reverse Current Time Relays',#7713,$,$); -#7715=IFCCLASSIFICATIONREFERENCE($,'23-35 43 35 11 11','Reverse Current Solid State Time Relays',#7714,$,$); -#7716=IFCCLASSIFICATIONREFERENCE($,'23-35 43 35 13','Reverse Power Time Relays',#7713,$,$); -#7717=IFCCLASSIFICATIONREFERENCE($,'23-35 43 35 13 11','Reverse Power Solid State Time Relays',#7716,$,$); -#7718=IFCCLASSIFICATIONREFERENCE($,'23-35 43 35 15','Power Factor Time Relays',#7713,$,$); -#7719=IFCCLASSIFICATIONREFERENCE($,'23-35 43 35 15 11','Power Factor Solid State Time Relays',#7718,$,$); -#7720=IFCCLASSIFICATIONREFERENCE($,'23-35 43 37','Voltage Relays',#7690,$,$); -#7721=IFCCLASSIFICATIONREFERENCE($,'23-35 43 37 11','Under Voltage Relays',#7720,$,$); -#7722=IFCCLASSIFICATIONREFERENCE($,'23-35 43 37 11 11','Under Voltage Solid State Relays',#7721,$,$); -#7723=IFCCLASSIFICATIONREFERENCE($,'23-35 43 37 13','Over Voltage Relays',#7720,$,$); -#7724=IFCCLASSIFICATIONREFERENCE($,'23-35 43 37 13 11','Over Voltage Solid State Relays',#7723,$,$); -#7725=IFCCLASSIFICATIONREFERENCE($,'23-35 43 37 15','Over Under Voltage Relays',#7720,$,$); -#7726=IFCCLASSIFICATIONREFERENCE($,'23-35 43 37 15 11','Over Under Voltage Solid State Relays',#7725,$,$); -#7727=IFCCLASSIFICATIONREFERENCE($,'23-35 45 00','Non Electrical Lighting',#7371,$,$); -#7728=IFCCLASSIFICATIONREFERENCE($,'23-35 45 11','Lanterns',#7727,$,$); -#7729=IFCCLASSIFICATIONREFERENCE($,'23-35 45 11 11','Alcohol Lanterns',#7728,$,$); -#7730=IFCCLASSIFICATIONREFERENCE($,'23-35 45 11 13','Butane Lanterns',#7728,$,$); -#7731=IFCCLASSIFICATIONREFERENCE($,'23-35 45 11 15','Kerosene Lanterns',#7728,$,$); -#7732=IFCCLASSIFICATIONREFERENCE($,'23-35 45 11 17','Natural Gas Lanterns',#7728,$,$); -#7733=IFCCLASSIFICATIONREFERENCE($,'23-35 45 11 19','Propane Lanterns',#7728,$,$); -#7734=IFCCLASSIFICATIONREFERENCE($,'23-35 45 13','Torches',#7727,$,$); -#7735=IFCCLASSIFICATIONREFERENCE($,'23-35 45 13 11','Alcohol Torches',#7734,$,$); -#7736=IFCCLASSIFICATIONREFERENCE($,'23-35 45 13 13','Butane Torches',#7734,$,$); -#7737=IFCCLASSIFICATIONREFERENCE($,'23-35 45 13 15','Kerosene Torches',#7734,$,$); -#7738=IFCCLASSIFICATIONREFERENCE($,'23-35 45 13 17','Natural Gas Torches',#7734,$,$); -#7739=IFCCLASSIFICATIONREFERENCE($,'23-35 45 13 19','Propane Torches',#7734,$,$); -#7740=IFCCLASSIFICATIONREFERENCE($,'23-35 45 15','Lamps',#7727,$,$); -#7741=IFCCLASSIFICATIONREFERENCE($,'23-35 45 15 11','Alcohol Lamps',#7740,$,$); -#7742=IFCCLASSIFICATIONREFERENCE($,'23-35 45 15 13','Butane Lamps',#7740,$,$); -#7743=IFCCLASSIFICATIONREFERENCE($,'23-35 45 15 15','Kerosene Lamps',#7740,$,$); -#7744=IFCCLASSIFICATIONREFERENCE($,'23-35 45 15 17','Natural Gas Lamps',#7740,$,$); -#7745=IFCCLASSIFICATIONREFERENCE($,'23-35 45 15 19','Propane Lamps',#7740,$,$); -#7746=IFCCLASSIFICATIONREFERENCE($,'23-35 45 17','Solar Tubes',#7727,$,$); -#7747=IFCCLASSIFICATIONREFERENCE($,'23-35 45 19','Strobe Light Fixtures',#7727,$,$); -#7748=IFCCLASSIFICATIONREFERENCE($,'23-35 47 00','Electrical Lighting',#7371,$,$); -#7749=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11','Lighting Fixtures',#7748,$,$); -#7750=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 11','Non Weather Rated Lighting Fixtures',#7749,$,$); -#7751=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 11 11','Non Weather Rated Fluorescent Lighting Fixtures',#7750,$,$); -#7752=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 11 13','Non Weather Rated Halogen Lighting Fixtures',#7750,$,$); -#7753=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 11 15','Non Weather Rated High Intensity Discharge Lighting Fixtures',#7750,$,$); -#7754=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 11 17','Non Weather Rated Incandescent Lighting Fixtures',#7750,$,$); -#7755=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 11 19','Non Weather Rated Light Emitting Diode Lighting Fixtures',#7750,$,$); -#7756=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 13','Submersible Lighting Fixtures',#7749,$,$); -#7757=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 13 11','Submersible Fluorescent Lighting Fixtures',#7756,$,$); -#7758=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 13 13','Submersible Halogen Lighting Fixtures',#7756,$,$); -#7759=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 13 15','Submersible High Intensity Discharge Lighting Fixtures',#7756,$,$); -#7760=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 13 17','Submersible Incandescent Lighting Fixtures',#7756,$,$); -#7761=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 13 19','Submersible Light Emitting Diode Lighting Fixtures',#7756,$,$); -#7762=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 15','Weather Rated Lighting Fixtures',#7749,$,$); -#7763=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 15 11','Weather Rated Fluorescent Lighting Fixtures',#7762,$,$); -#7764=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 15 13','Weather Rated Halogen Lighting Fixtures',#7762,$,$); -#7765=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 15 15','Weather Rated High Intensity Discharge Lighting Fixtures',#7762,$,$); -#7766=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 15 17','Weather Rated Incandescent Lighting Fixtures',#7762,$,$); -#7767=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 15 19','Weather Rated Light Emitting Diode Lighting Fixtures',#7762,$,$); -#7768=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 17','Chandelier',#7749,$,$); -#7769=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 18','Explosion Proof Lighting Fixtures',#7749,$,$); -#7770=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 18 11','Explosion Proof Fluorescent Lighting Fixtures',#7769,$,$); -#7771=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 18 13','Explosion Proof Halogen Lighting Fixtures',#7769,$,$); -#7772=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 18 15','Explosion Proof High Intensity Discharge Lighting Fixtures',#7769,$,$); -#7773=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 18 17','Explosion Proof Incandescent Lighting Fixtures',#7769,$,$); -#7774=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 18 19','Explosion Proof Light Emitting Diode Lighting Fixtures',#7769,$,$); -#7775=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 19','Hazardous Lighting Fixtures',#7749,$,$); -#7776=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 19 11','Hazardous Fluorescent Lighting Fixtures',#7775,$,$); -#7777=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 19 13','Hazardous Halogen Lighting Fixtures',#7775,$,$); -#7778=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 19 15','Hazardous High Intensity Discharge Lighting Fixtures',#7775,$,$); -#7779=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 19 17','Hazardous Incandescent Lighting Fixtures',#7775,$,$); -#7780=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 19 19','Hazardous Light Emitting Diode Lighting Fixtures',#7775,$,$); -#7781=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 20','Security Lighting Fixtures',#7749,$,$); -#7782=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 21','Specialized Lighting Fixtures',#7749,$,$); -#7783=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 21 11','Lighting Bollards',#7782,$,$); -#7784=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 21 13','Lighting Poles',#7782,$,$); -#7785=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 21 15','Lighting Posts',#7782,$,$); -#7786=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 21 17','Buried Uplights',#7782,$,$); -#7787=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 21 19','Floodlight Fixtures',#7782,$,$); -#7788=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 21 21','Spotlight Fixtures',#7782,$,$); -#7789=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 21 21 11','Focus Spotlight Fixture',#7788,$,$); -#7790=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 21 21 13','Follow Spotlight Fixture',#7788,$,$); -#7791=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 21 21 15','Spotlight Bank Fixture',#7788,$,$); -#7792=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 21 21 17','Pin Spotlight Fixture',#7788,$,$); -#7793=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 21 23','Street and Roadway Lighting Fixtures',#7782,$,$); -#7794=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 21 25','Aircraft Paving Lighting Fixtures',#7782,$,$); -#7795=IFCCLASSIFICATIONREFERENCE($,'23-35 47 13','Emergency Lighting',#7748,$,$); -#7796=IFCCLASSIFICATIONREFERENCE($,'23-35 47 13 11','Hard Wired Emergency Lighting',#7795,$,$); -#7797=IFCCLASSIFICATIONREFERENCE($,'23-35 47 13 13','Emergency Lighting With Battery Backup',#7795,$,$); -#7798=IFCCLASSIFICATIONREFERENCE($,'23-35 47 13 15','Passive Emergency Lighting Strips',#7795,$,$); -#7799=IFCCLASSIFICATIONREFERENCE($,'23-35 47 13 17','Emergency Lighting Strobe',#7795,$,$); -#7800=IFCCLASSIFICATIONREFERENCE($,'23-35 47 15','Exit Illuminated Signs',#7748,$,$); -#7801=IFCCLASSIFICATIONREFERENCE($,'23-35 47 15 11','Battery Backup Exit Illuminated Signs',#7800,$,$); -#7802=IFCCLASSIFICATIONREFERENCE($,'23-35 47 15 13','Hard Wired Backup Exit Illuminated Signs',#7800,$,$); -#7803=IFCCLASSIFICATIONREFERENCE($,'23-35 47 15 15','Self Illuminated Exit Illuminated Signs',#7800,$,$); -#7804=IFCCLASSIFICATIONREFERENCE($,'23-35 47 17','Fiber Optic Lighting',#7748,$,$); -#7805=IFCCLASSIFICATIONREFERENCE($,'23-35 47 19','Communication Lighting Specialties',#7748,$,$); -#7806=IFCCLASSIFICATIONREFERENCE($,'23-35 47 19 11','Illuminated Signs Boards',#7805,$,$); -#7807=IFCCLASSIFICATIONREFERENCE($,'23-35 47 21','Accessories for Lighting',#7748,$,$); -#7808=IFCCLASSIFICATIONREFERENCE($,'23-35 47 21 11','Lampholders',#7807,$,$); -#7809=IFCCLASSIFICATIONREFERENCE($,'23-35 47 21 13','Lighting Diffusers',#7807,$,$); -#7810=IFCCLASSIFICATIONREFERENCE($,'23-35 47 21 15','Lighting Ballasts',#7807,$,$); -#7811=IFCCLASSIFICATIONREFERENCE($,'23-35 47 21 17','Lighting Tracks',#7807,$,$); -#7812=IFCCLASSIFICATIONREFERENCE($,'23-35 47 21 19','Lampshades',#7807,$,$); -#7813=IFCCLASSIFICATIONREFERENCE($,'23-35 47 23','Lamps',#7748,$,$); -#7814=IFCCLASSIFICATIONREFERENCE($,'23-35 47 23 11','Halogen Lamps',#7813,$,$); -#7815=IFCCLASSIFICATIONREFERENCE($,'23-35 47 23 13','Incandescent Lamps',#7813,$,$); -#7816=IFCCLASSIFICATIONREFERENCE($,'23-35 47 23 15','Discharge Lamps',#7813,$,$); -#7817=IFCCLASSIFICATIONREFERENCE($,'23-35 47 23 15 11','Fluorescent Lamps',#7816,$,$); -#7818=IFCCLASSIFICATIONREFERENCE($,'23-35 47 23 15 13','Compact Fluorescent Lamps',#7816,$,$); -#7819=IFCCLASSIFICATIONREFERENCE($,'23-35 47 23 15 15','Sodium Vapor Lamps',#7816,$,$); -#7820=IFCCLASSIFICATIONREFERENCE($,'23-35 47 23 15 17','High Pressure Discharge Lamps',#7816,$,$); -#7821=IFCCLASSIFICATIONREFERENCE($,'23-35 47 23 17','Light Emitting Diode Lamps',#7813,$,$); -#7822=IFCCLASSIFICATIONREFERENCE($,'23-37 00 00','Information and Communication Specific Products and Equipment',#1604,$,$); -#7823=IFCCLASSIFICATIONREFERENCE($,'23-37 11 00','Information Technology and Telecommunications Ducting Wireways Components',#7822,$,$); -#7824=IFCCLASSIFICATIONREFERENCE($,'23-37 11 11','Communication Service Penetrations',#7823,$,$); -#7825=IFCCLASSIFICATIONREFERENCE($,'23-37 11 13','Communication Cable Trays',#7823,$,$); -#7826=IFCCLASSIFICATIONREFERENCE($,'23-37 11 15','Communication Racks',#7823,$,$); -#7827=IFCCLASSIFICATIONREFERENCE($,'23-37 11 15 11','Information Technology Racks',#7826,$,$); -#7828=IFCCLASSIFICATIONREFERENCE($,'23-37 11 15 13','Telephone Racks',#7826,$,$); -#7829=IFCCLASSIFICATIONREFERENCE($,'23-37 11 15 15','Fiber Optic Equipment',#7826,$,$); -#7830=IFCCLASSIFICATIONREFERENCE($,'23-37 11 15 15 11','Fiber Optic Cabinets',#7829,$,$); -#7831=IFCCLASSIFICATIONREFERENCE($,'23-37 11 15 15 13','Fiber Adapter Panels',#7829,$,$); -#7832=IFCCLASSIFICATIONREFERENCE($,'23-37 11 17','Communication Wireways',#7823,$,$); -#7833=IFCCLASSIFICATIONREFERENCE($,'23-37 11 17 11','Information Technology Wireways',#7832,$,$); -#7834=IFCCLASSIFICATIONREFERENCE($,'23-37 11 17 11 11','Underfloor Information Technology Wireways',#7833,$,$); -#7835=IFCCLASSIFICATIONREFERENCE($,'23-37 11 17 11 13','Vertical Information Technology Wire Raceways',#7833,$,$); -#7836=IFCCLASSIFICATIONREFERENCE($,'23-37 11 17 11 15','Horizontal Information Technology Wire Raceways',#7833,$,$); -#7837=IFCCLASSIFICATIONREFERENCE($,'23-37 11 17 13','Telecommunications Wireways',#7832,$,$); -#7838=IFCCLASSIFICATIONREFERENCE($,'23-37 11 17 13 11','Underfloor Telecommunications Wireways',#7837,$,$); -#7839=IFCCLASSIFICATIONREFERENCE($,'23-37 11 17 13 13','Vertical Telecommunications Wire Raceways',#7837,$,$); -#7840=IFCCLASSIFICATIONREFERENCE($,'23-37 11 17 13 15','Horizontal Telecommunications Wire Raceways',#7837,$,$); -#7841=IFCCLASSIFICATIONREFERENCE($,'23-37 11 17 15','Complete Visual Signaling',#7832,$,$); -#7842=IFCCLASSIFICATIONREFERENCE($,'23-37 11 17 15 11','Mechanical Signal Equipment',#7841,$,$); -#7843=IFCCLASSIFICATIONREFERENCE($,'23-37 13 00','Information Technology Equipment',#7822,$,$); -#7844=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11','Personal Computer Equipment',#7843,$,$); -#7845=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11 11','Desktop Personal Computers',#7844,$,$); -#7846=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11 13','Laptop Personal Computers',#7844,$,$); -#7847=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11 15','Tablet Personal Computers',#7844,$,$); -#7848=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11 17','Tower Stack Personal Computers',#7844,$,$); -#7849=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11 19','Workstation Personal Computers',#7844,$,$); -#7850=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11 21','Personal Digital Assistants',#7844,$,$); -#7851=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11 23','Internal Computing Components',#7844,$,$); -#7852=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11 23 11','Computer Processing Units',#7851,$,$); -#7853=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11 23 13','Computer Controller Cards',#7851,$,$); -#7854=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11 23 15','Computer Memory Cards',#7851,$,$); -#7855=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11 23 17','Personal Computer Modem Cards',#7851,$,$); -#7856=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11 23 19','Personal Computer Network Interface Cards',#7851,$,$); -#7857=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11 23 21','Personal Computer Video Cards',#7851,$,$); -#7858=IFCCLASSIFICATIONREFERENCE($,'23-37 13 13','Personal Computer and Network Security Devices',#7843,$,$); -#7859=IFCCLASSIFICATIONREFERENCE($,'23-37 13 13 11','Computer Firewalls',#7858,$,$); -#7860=IFCCLASSIFICATIONREFERENCE($,'23-37 13 13 13','Computer Intrusion Detection Devices',#7858,$,$); -#7861=IFCCLASSIFICATIONREFERENCE($,'23-37 13 13 15','Computer Intrusion Protection Devices',#7858,$,$); -#7862=IFCCLASSIFICATIONREFERENCE($,'23-37 13 15','Local Area Network Devices',#7843,$,$); -#7863=IFCCLASSIFICATIONREFERENCE($,'23-37 13 15 11','Local Area Network Bridges',#7862,$,$); -#7864=IFCCLASSIFICATIONREFERENCE($,'23-37 13 15 13','Local Area Network Communication Hardware',#7862,$,$); -#7865=IFCCLASSIFICATIONREFERENCE($,'23-37 13 15 15','Local Area Network Disk Drives',#7862,$,$); -#7866=IFCCLASSIFICATIONREFERENCE($,'23-37 13 15 17','Local Area Network Hubs',#7862,$,$); -#7867=IFCCLASSIFICATIONREFERENCE($,'23-37 13 15 19','Local Area Network Load Balancers',#7862,$,$); -#7868=IFCCLASSIFICATIONREFERENCE($,'23-37 13 15 21','Local Area Network Routers',#7862,$,$); -#7869=IFCCLASSIFICATIONREFERENCE($,'23-37 13 15 23','Local Area Network Servers',#7862,$,$); -#7870=IFCCLASSIFICATIONREFERENCE($,'23-37 13 15 25','Local Area Network Switches',#7862,$,$); -#7871=IFCCLASSIFICATIONREFERENCE($,'23-37 13 15 27','Local Area Network Tape Drives',#7862,$,$); -#7872=IFCCLASSIFICATIONREFERENCE($,'23-37 13 15 29','Local Area Network Wireless Devices',#7862,$,$); -#7873=IFCCLASSIFICATIONREFERENCE($,'23-37 13 17','Wide Area Network Devices',#7843,$,$); -#7874=IFCCLASSIFICATIONREFERENCE($,'23-37 13 17 11','Wide Area Network Bridges',#7873,$,$); -#7875=IFCCLASSIFICATIONREFERENCE($,'23-37 13 17 13','Wide Area Network Communication Hardware',#7873,$,$); -#7876=IFCCLASSIFICATIONREFERENCE($,'23-37 13 17 15','Wide Area Network Disk Drives',#7873,$,$); -#7877=IFCCLASSIFICATIONREFERENCE($,'23-37 13 17 17','Wide Area Network Hubs',#7873,$,$); -#7878=IFCCLASSIFICATIONREFERENCE($,'23-37 13 17 19','Wide Area Network Load Balancers',#7873,$,$); -#7879=IFCCLASSIFICATIONREFERENCE($,'23-37 13 17 21','Wide Area Network Routers',#7873,$,$); -#7880=IFCCLASSIFICATIONREFERENCE($,'23-37 13 17 23','Wide Area Network Servers',#7873,$,$); -#7881=IFCCLASSIFICATIONREFERENCE($,'23-37 13 17 25','Wide Area Network Switches',#7873,$,$); -#7882=IFCCLASSIFICATIONREFERENCE($,'23-37 13 17 27','Wide Area Network Tape Drives',#7873,$,$); -#7883=IFCCLASSIFICATIONREFERENCE($,'23-37 13 17 29','Wide Area Network Wireless Devices',#7873,$,$); -#7884=IFCCLASSIFICATIONREFERENCE($,'23-37 13 19','Computer Storage Devices',#7843,$,$); -#7885=IFCCLASSIFICATIONREFERENCE($,'23-37 13 19 11','Computer Optic Drives',#7884,$,$); -#7886=IFCCLASSIFICATIONREFERENCE($,'23-37 13 19 11 11','Compact Disk Drives',#7885,$,$); -#7887=IFCCLASSIFICATIONREFERENCE($,'23-37 13 19 11 13','Digital Video Disc Drives',#7885,$,$); -#7888=IFCCLASSIFICATIONREFERENCE($,'23-37 13 19 11 15','Combination Compact Disk and Digital Video Disc Drives',#7885,$,$); -#7889=IFCCLASSIFICATIONREFERENCE($,'23-37 13 19 13','Hard Disk Drives',#7884,$,$); -#7890=IFCCLASSIFICATIONREFERENCE($,'23-37 13 19 15','Flash Memory Drives',#7884,$,$); -#7891=IFCCLASSIFICATIONREFERENCE($,'23-37 13 19 17','Computer Tape Drives',#7884,$,$); -#7892=IFCCLASSIFICATIONREFERENCE($,'23-37 13 21','Computer Monitors',#7843,$,$); -#7893=IFCCLASSIFICATIONREFERENCE($,'23-37 13 21 11','Computer Liquid Crystal Display Monitors',#7892,$,$); -#7894=IFCCLASSIFICATIONREFERENCE($,'23-37 13 21 13','Computer Catho Ray Tube Monitors',#7892,$,$); -#7895=IFCCLASSIFICATIONREFERENCE($,'23-37 13 23','Computer Printers',#7843,$,$); -#7896=IFCCLASSIFICATIONREFERENCE($,'23-37 13 23 11','Computer Laser Printers',#7895,$,$); -#7897=IFCCLASSIFICATIONREFERENCE($,'23-37 13 23 13','Computer Inkjet Printers',#7895,$,$); -#7898=IFCCLASSIFICATIONREFERENCE($,'23-37 13 23 15','Computer Plotter Printers',#7895,$,$); -#7899=IFCCLASSIFICATIONREFERENCE($,'23-37 13 25','Computer Scanners',#7843,$,$); -#7900=IFCCLASSIFICATIONREFERENCE($,'23-37 13 27','Computer Video Conferencing Equipment',#7843,$,$); -#7901=IFCCLASSIFICATIONREFERENCE($,'23-37 15 00','Audio Visual Equipment',#7822,$,$); -#7902=IFCCLASSIFICATIONREFERENCE($,'23-37 15 11','Cameras',#7901,$,$); -#7903=IFCCLASSIFICATIONREFERENCE($,'23-37 15 11 11','Analog Cameras',#7902,$,$); -#7904=IFCCLASSIFICATIONREFERENCE($,'23-37 15 11 13','Digital Cameras',#7902,$,$); -#7905=IFCCLASSIFICATIONREFERENCE($,'23-37 15 13','Camera Recorders',#7901,$,$); -#7906=IFCCLASSIFICATIONREFERENCE($,'23-37 15 13 11','Digital Camcorders',#7905,$,$); -#7907=IFCCLASSIFICATIONREFERENCE($,'23-37 15 13 13','Film Camcorders',#7905,$,$); -#7908=IFCCLASSIFICATIONREFERENCE($,'23-37 15 15','Digital Music Players',#7901,$,$); -#7909=IFCCLASSIFICATIONREFERENCE($,'23-37 15 17','Projection Equipment',#7901,$,$); -#7910=IFCCLASSIFICATIONREFERENCE($,'23-37 15 17 11','Projection Screens',#7909,$,$); -#7911=IFCCLASSIFICATIONREFERENCE($,'23-37 15 17 13','Projection Screen Stands',#7909,$,$); -#7912=IFCCLASSIFICATIONREFERENCE($,'23-37 15 19','Video Projectors',#7901,$,$); -#7913=IFCCLASSIFICATIONREFERENCE($,'23-37 15 19 11','Video Slide Projectors',#7912,$,$); -#7914=IFCCLASSIFICATIONREFERENCE($,'23-37 15 19 13','Video Overhead Projectors',#7912,$,$); -#7915=IFCCLASSIFICATIONREFERENCE($,'23-37 15 19 15','Video Film Projectors',#7912,$,$); -#7916=IFCCLASSIFICATIONREFERENCE($,'23-37 15 19 17','Video Slide Projectors',#7912,$,$); -#7917=IFCCLASSIFICATIONREFERENCE($,'23-37 15 19 19','Video Digital Projectors',#7912,$,$); -#7918=IFCCLASSIFICATIONREFERENCE($,'23-37 15 21','Audio Visual Recorders',#7901,$,$); -#7919=IFCCLASSIFICATIONREFERENCE($,'23-37 15 21 11','Audio Recorders',#7918,$,$); -#7920=IFCCLASSIFICATIONREFERENCE($,'23-37 15 21 13','Video Recorders',#7918,$,$); -#7921=IFCCLASSIFICATIONREFERENCE($,'23-37 15 21 15','Audio Video Recorders',#7918,$,$); -#7922=IFCCLASSIFICATIONREFERENCE($,'23-37 15 23','Stereo Equipment',#7901,$,$); -#7923=IFCCLASSIFICATIONREFERENCE($,'23-37 15 23 11','Stereo Amplifiers',#7922,$,$); -#7924=IFCCLASSIFICATIONREFERENCE($,'23-37 15 23 13','Stereo Patch Panels',#7922,$,$); -#7925=IFCCLASSIFICATIONREFERENCE($,'23-37 15 23 15','Stereo Speakers',#7922,$,$); -#7926=IFCCLASSIFICATIONREFERENCE($,'23-37 15 25','Televisions',#7901,$,$); -#7927=IFCCLASSIFICATIONREFERENCE($,'23-37 15 25 11','Cathoray Tube Televisions',#7926,$,$); -#7928=IFCCLASSIFICATIONREFERENCE($,'23-37 15 25 13','Liquid Crystal Display Televisions',#7926,$,$); -#7929=IFCCLASSIFICATIONREFERENCE($,'23-37 15 25 15','Plasma Display Televisions',#7926,$,$); -#7930=IFCCLASSIFICATIONREFERENCE($,'23-37 15 25 17','Projection Screen Televisions',#7926,$,$); -#7931=IFCCLASSIFICATIONREFERENCE($,'23-37 15 25 19','Television Mounts',#7926,$,$); -#7932=IFCCLASSIFICATIONREFERENCE($,'23-37 15 27','Video Recording Equipment',#7901,$,$); -#7933=IFCCLASSIFICATIONREFERENCE($,'23-37 15 29','Audio Equipment',#7901,$,$); -#7934=IFCCLASSIFICATIONREFERENCE($,'23-37 15 29 11','Sound Reinforcement Equipment',#7933,$,$); -#7935=IFCCLASSIFICATIONREFERENCE($,'23-37 15 29 11 11','Microphones',#7934,$,$); -#7936=IFCCLASSIFICATIONREFERENCE($,'23-37 15 29 11 13','Loudspeakers',#7934,$,$); -#7937=IFCCLASSIFICATIONREFERENCE($,'23-37 15 29 11 15','Sound Amplifiers',#7934,$,$); -#7938=IFCCLASSIFICATIONREFERENCE($,'23-37 15 29 11 17','Audio Equalizers',#7934,$,$); -#7939=IFCCLASSIFICATIONREFERENCE($,'23-37 15 29 13','Headphones',#7933,$,$); -#7940=IFCCLASSIFICATIONREFERENCE($,'23-37 15 29 15','Audio Reproducing Units',#7933,$,$); -#7941=IFCCLASSIFICATIONREFERENCE($,'23-37 17 00','Audio Information Equipment',#7822,$,$); -#7942=IFCCLASSIFICATIONREFERENCE($,'23-37 17 11','Sound Devices',#7941,$,$); -#7943=IFCCLASSIFICATIONREFERENCE($,'23-37 17 13','Signal Devices',#7941,$,$); -#7944=IFCCLASSIFICATIONREFERENCE($,'23-37 17 13 11','Bells',#7943,$,$); -#7945=IFCCLASSIFICATIONREFERENCE($,'23-37 17 13 13','Carillons',#7943,$,$); -#7946=IFCCLASSIFICATIONREFERENCE($,'23-37 17 13 15','Sirens',#7943,$,$); -#7947=IFCCLASSIFICATIONREFERENCE($,'23-37 17 13 17','Aerials',#7943,$,$); -#7948=IFCCLASSIFICATIONREFERENCE($,'23-37 17 13 19','Speakers',#7943,$,$); -#7949=IFCCLASSIFICATIONREFERENCE($,'23-37 17 15','Public Address Equipment',#7941,$,$); -#7950=IFCCLASSIFICATIONREFERENCE($,'23-37 19 00','Visual Information Systems',#7822,$,$); -#7951=IFCCLASSIFICATIONREFERENCE($,'23-37 19 11','Cathode Ray Tube (CRT) Video Monitors',#7950,$,$); -#7952=IFCCLASSIFICATIONREFERENCE($,'23-37 19 13','Liquid Crystal Display (LCD) Video Monitors',#7950,$,$); -#7953=IFCCLASSIFICATIONREFERENCE($,'23-37 19 15','Plasma Video Monitors',#7950,$,$); -#7954=IFCCLASSIFICATIONREFERENCE($,'23-37 19 17','Video Walls',#7950,$,$); -#7955=IFCCLASSIFICATIONREFERENCE($,'23-37 21 00','Audio Visual Systems',#7822,$,$); -#7956=IFCCLASSIFICATIONREFERENCE($,'23-37 21 11','Broadcasting Receiving Equipment',#7955,$,$); -#7957=IFCCLASSIFICATIONREFERENCE($,'23-37 21 13','Film Projectors',#7955,$,$); -#7958=IFCCLASSIFICATIONREFERENCE($,'23-37 21 15','Data Multi Media Projectors',#7955,$,$); -#7959=IFCCLASSIFICATIONREFERENCE($,'23-37 21 17','Video Reproduction',#7955,$,$); -#7960=IFCCLASSIFICATIONREFERENCE($,'23-37 23 00','Telecommunications Equipment',#7822,$,$); -#7961=IFCCLASSIFICATIONREFERENCE($,'23-37 23 11','Wireless Phone Equipment',#7960,$,$); -#7962=IFCCLASSIFICATIONREFERENCE($,'23-37 23 11 11','Wireless Phones',#7961,$,$); -#7963=IFCCLASSIFICATIONREFERENCE($,'23-37 23 11 13','Wireless Phone Chargers',#7961,$,$); -#7964=IFCCLASSIFICATIONREFERENCE($,'23-37 23 13','Telephones',#7960,$,$); -#7965=IFCCLASSIFICATIONREFERENCE($,'23-37 23 13 11','Single Line Telephones',#7964,$,$); -#7966=IFCCLASSIFICATIONREFERENCE($,'23-37 23 13 13','Multiple Line Telephones',#7964,$,$); -#7967=IFCCLASSIFICATIONREFERENCE($,'23-37 23 15','Telephone Equipment',#7960,$,$); -#7968=IFCCLASSIFICATIONREFERENCE($,'23-37 23 15 11','Private Branch Exchanges',#7967,$,$); -#7969=IFCCLASSIFICATIONREFERENCE($,'23-37 23 15 13','Telephone Patch Panels',#7967,$,$); -#7970=IFCCLASSIFICATIONREFERENCE($,'23-37 23 17','Intercom Equipment',#7960,$,$); -#7971=IFCCLASSIFICATIONREFERENCE($,'23-37 23 17 11','Intercoms',#7970,$,$); -#7972=IFCCLASSIFICATIONREFERENCE($,'23-37 23 17 13','Door Entry Telephones',#7970,$,$); -#7973=IFCCLASSIFICATIONREFERENCE($,'23-37 23 19','Radio Broadcast Equipment',#7960,$,$); -#7974=IFCCLASSIFICATIONREFERENCE($,'23-37 23 19 11','Radio Booths',#7973,$,$); -#7975=IFCCLASSIFICATIONREFERENCE($,'23-37 23 19 11 11','Radio Broadcast Booths',#7974,$,$); -#7976=IFCCLASSIFICATIONREFERENCE($,'23-37 23 19 11 13','Radio Recording Booths',#7974,$,$); -#7977=IFCCLASSIFICATIONREFERENCE($,'23-37 23 19 13','Radio Broadcast Transmitters',#7973,$,$); -#7978=IFCCLASSIFICATIONREFERENCE($,'23-37 23 19 15','Radio Broadcast Receivers',#7973,$,$); -#7979=IFCCLASSIFICATIONREFERENCE($,'23-37 23 19 17','Radio Communication Base Stations',#7973,$,$); -#7980=IFCCLASSIFICATIONREFERENCE($,'23-37 23 19 19','Radio Communication Call Microphones',#7973,$,$); -#7981=IFCCLASSIFICATIONREFERENCE($,'23-37 23 19 21','Radio Broadcast Transmission Towers',#7973,$,$); -#7982=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21','Radio Communication Equipment',#7960,$,$); -#7983=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 11','Infra Red Radio Communication Equipment',#7982,$,$); -#7984=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 11 11','Infra Red Radio Communication Receivers',#7983,$,$); -#7985=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 11 13','Infra Red Radio Communication Transmitters',#7983,$,$); -#7986=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 11 15','Infra Red Radio Communication Transmitter Receivers',#7983,$,$); -#7987=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 13','Satellite Radio Communication Equipment',#7982,$,$); -#7988=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 13 11','Satellite Radio Communication Transmitters',#7987,$,$); -#7989=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 13 13','Satellite Radio Communication Transmitter Receivers',#7987,$,$); -#7990=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 13 15','Satellite Radio Communications Receivers',#7987,$,$); -#7991=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 15','Wireless Radio Communication Equipment',#7982,$,$); -#7992=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 15 11','Wireless Radio Communication Receivers',#7991,$,$); -#7993=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 15 13','Wireless Radio Communication Transmitters',#7991,$,$); -#7994=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 15 15','Wireless Radio Communication Transmitter Receivers',#7991,$,$); -#7995=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 17','Radio Communication Antenna Towers',#7982,$,$); -#7996=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 19','Radio Communication Transmission Towers',#7982,$,$); -#7997=IFCCLASSIFICATIONREFERENCE($,'23-37 23 23','Satellite Communication Equipment',#7960,$,$); -#7998=IFCCLASSIFICATIONREFERENCE($,'23-37 23 23 11','Satellite Communication Dishes',#7997,$,$); -#7999=IFCCLASSIFICATIONREFERENCE($,'23-37 25 00','Broadcasting Communications Equipment',#7822,$,$); -#8000=IFCCLASSIFICATIONREFERENCE($,'23-37 25 11','Broadcasting Communication Circuits',#7999,$,$); -#8001=IFCCLASSIFICATIONREFERENCE($,'23-37 25 13','Broadcasting Intercommunication Equipment',#7999,$,$); -#8002=IFCCLASSIFICATIONREFERENCE($,'23-37 25 15','Broadcasting Communication and Data Processing Equipment',#7999,$,$); -#8003=IFCCLASSIFICATIONREFERENCE($,'23-37 25 17','Broadcasting Cable Transmission and Reception Equipment',#7999,$,$); -#8004=IFCCLASSIFICATIONREFERENCE($,'23-37 25 17 11','Broadcasting Cable Transmission and Reception Amplifiers',#8003,$,$); -#8005=IFCCLASSIFICATIONREFERENCE($,'23-37 25 17 13','Broadcasting Cable Transmission and Reception Modulators',#8003,$,$); -#8006=IFCCLASSIFICATIONREFERENCE($,'23-37 25 17 15','Broadcasting Cable Transmission and Reception Control Equipment',#8003,$,$); -#8007=IFCCLASSIFICATIONREFERENCE($,'23-37 25 19','Broadcast Transmission and Reception Equipment',#7999,$,$); -#8008=IFCCLASSIFICATIONREFERENCE($,'23-37 25 19 11','Broadcast Transmitters',#8007,$,$); -#8009=IFCCLASSIFICATIONREFERENCE($,'23-37 25 19 13','Broadcast Antennas',#8007,$,$); -#8010=IFCCLASSIFICATIONREFERENCE($,'23-37 25 19 15','Broadcast Amplifiers',#8007,$,$); -#8011=IFCCLASSIFICATIONREFERENCE($,'23-37 25 19 17','Broadcast Control Equipment',#8007,$,$); -#8012=IFCCLASSIFICATIONREFERENCE($,'23-37 25 21','Broadcasting Microwave Transmission and Reception Equipment',#7999,$,$); -#8013=IFCCLASSIFICATIONREFERENCE($,'23-37 25 21 11','Broadcasting Microwave Transmitters',#8012,$,$); -#8014=IFCCLASSIFICATIONREFERENCE($,'23-37 25 21 13','Broadcasting Microwave Antennas',#8012,$,$); -#8015=IFCCLASSIFICATIONREFERENCE($,'23-37 25 21 15','Broadcasting Satellite Dishes',#8012,$,$); -#8016=IFCCLASSIFICATIONREFERENCE($,'23-37 25 21 17','Broadcasting Microwave Amplifiers',#8012,$,$); -#8017=IFCCLASSIFICATIONREFERENCE($,'23-37 25 21 19','Broadcasting Microwave Receivers',#8012,$,$); -#8018=IFCCLASSIFICATIONREFERENCE($,'23-37 25 23','Broadcasting Equipment',#7999,$,$); -#8019=IFCCLASSIFICATIONREFERENCE($,'23-37 25 23 11','Television Broadcasting Equipment',#8018,$,$); -#8020=IFCCLASSIFICATIONREFERENCE($,'23-37 25 23 13','Multimedia Broadcasting Equipment',#8018,$,$); -#8021=IFCCLASSIFICATIONREFERENCE($,'23-37 25 23 15','Broadcasting Light Signals',#8018,$,$); -#8022=IFCCLASSIFICATIONREFERENCE($,'23-37 27 00','Emergency Communications',#7822,$,$); -#8023=IFCCLASSIFICATIONREFERENCE($,'23-37 27 11','Duress Notification Devices',#8022,$,$); -#8024=IFCCLASSIFICATIONREFERENCE($,'23-37 27 13','Mass Notification Systems',#8022,$,$); -#8025=IFCCLASSIFICATIONREFERENCE($,'23-37 27 13 11','Emergency Notification Devices',#8024,$,$); -#8026=IFCCLASSIFICATIONREFERENCE($,'23-37 27 13 13','Imminent Danger Notification Devices',#8024,$,$); -#8027=IFCCLASSIFICATIONREFERENCE($,'23-37 27 15','Intercoms',#8022,$,$); -#8028=IFCCLASSIFICATIONREFERENCE($,'23-37 27 15 11','Audio Intercoms',#8027,$,$); -#8029=IFCCLASSIFICATIONREFERENCE($,'23-37 27 15 13','Audio Visual Intercoms',#8027,$,$); -#8030=IFCCLASSIFICATIONREFERENCE($,'23-37 27 17','Emergency Call Equipment',#8022,$,$); -#8031=IFCCLASSIFICATIONREFERENCE($,'23-37 27 17 11','Call Systems for the Disabled',#8030,$,$); -#8032=IFCCLASSIFICATIONREFERENCE($,'23-37 27 17 13','Nurse Call Equipment',#8030,$,$); -#8033=IFCCLASSIFICATIONREFERENCE($,'23-39 00 00','Utility and Transportation Products',#1604,$,$); -#8034=IFCCLASSIFICATIONREFERENCE($,'23-39 11 00','Roadway Monitoring and Control',#8033,$,$); -#8035=IFCCLASSIFICATIONREFERENCE($,'23-39 11 11','Traffic Safety Barriers and Protections',#8034,$,$); -#8036=IFCCLASSIFICATIONREFERENCE($,'23-39 11 11 11','Safety Barriers',#8035,$,$); -#8037=IFCCLASSIFICATIONREFERENCE($,'23-39 11 11 11 11','Crash Barriers ( including Impact Attenuating Devices)',#8036,$,$); -#8038=IFCCLASSIFICATIONREFERENCE($,'23-39 11 11 11 13','Median Barriers',#8036,$,$); -#8039=IFCCLASSIFICATIONREFERENCE($,'23-39 11 11 11 15','Guardrails',#8036,$,$); -#8040=IFCCLASSIFICATIONREFERENCE($,'23-39 11 11 13','Noise Barriers',#8035,$,$); -#8041=IFCCLASSIFICATIONREFERENCE($,'23-39 11 11 15','Traffic Barriers',#8035,$,$); -#8042=IFCCLASSIFICATIONREFERENCE($,'23-39 11 11 15 11','Traffic Delineators',#8041,$,$); -#8043=IFCCLASSIFICATIONREFERENCE($,'23-39 11 11 17','Traffic Control',#8035,$,$); -#8044=IFCCLASSIFICATIONREFERENCE($,'23-39 11 11 17 11','Traffic Speed Bumps',#8043,$,$); -#8045=IFCCLASSIFICATIONREFERENCE($,'23-39 11 11 19','Roadway Curbs',#8035,$,$); -#8046=IFCCLASSIFICATIONREFERENCE($,'23-39 11 11 21','Roadway Gutters',#8035,$,$); -#8047=IFCCLASSIFICATIONREFERENCE($,'23-39 11 11 23','Roadway Cattle Guards',#8035,$,$); -#8048=IFCCLASSIFICATIONREFERENCE($,'23-39 11 13','Roadway Signage',#8034,$,$); -#8049=IFCCLASSIFICATIONREFERENCE($,'23-39 11 15','Roadway Markers',#8034,$,$); -#8050=IFCCLASSIFICATIONREFERENCE($,'23-39 11 15 11','Roadway Surface Markings',#8049,$,$); -#8051=IFCCLASSIFICATIONREFERENCE($,'23-39 11 15 13','Roadway Reflectors',#8049,$,$); -#8052=IFCCLASSIFICATIONREFERENCE($,'23-39 11 15 15','Traffic Cones',#8049,$,$); -#8053=IFCCLASSIFICATIONREFERENCE($,'23-39 11 15 17','Traffic Signals',#8049,$,$); -#8054=IFCCLASSIFICATIONREFERENCE($,'23-39 11 15 19','Traffic Monitoring Equipment',#8049,$,$); -#8055=IFCCLASSIFICATIONREFERENCE($,'23-39 11 15 21','Roadway Mirrors',#8049,$,$); -#8056=IFCCLASSIFICATIONREFERENCE($,'23-39 11 15 23','Traffic Cameras',#8049,$,$); -#8057=IFCCLASSIFICATIONREFERENCE($,'23-39 11 15 25','Traffic Detectors and Sensors',#8049,$,$); -#8058=IFCCLASSIFICATIONREFERENCE($,'23-39 11 17','Vehicle Control Barriers',#8034,$,$); -#8059=IFCCLASSIFICATIONREFERENCE($,'23-39 11 17 11','Anti Ram Planters',#8058,$,$); -#8060=IFCCLASSIFICATIONREFERENCE($,'23-39 11 17 13','Jersey Barriers',#8058,$,$); -#8061=IFCCLASSIFICATIONREFERENCE($,'23-39 11 17 15','Active Tire Shredders',#8058,$,$); -#8062=IFCCLASSIFICATIONREFERENCE($,'23-39 11 17 17','Passive Tire Shredders',#8058,$,$); -#8063=IFCCLASSIFICATIONREFERENCE($,'23-39 11 19','Bollards',#8034,$,$); -#8064=IFCCLASSIFICATIONREFERENCE($,'23-39 11 19 11','Active Anti Ram Bollards',#8063,$,$); -#8065=IFCCLASSIFICATIONREFERENCE($,'23-39 11 19 13','Passive Anti Ram Bollards',#8063,$,$); -#8066=IFCCLASSIFICATIONREFERENCE($,'23-39 11 19 15','Architectural Bollards',#8063,$,$); -#8067=IFCCLASSIFICATIONREFERENCE($,'23-39 13 00','Tunnels and Bridges',#8033,$,$); -#8068=IFCCLASSIFICATIONREFERENCE($,'23-39 13 11','Tunnels',#8067,$,$); -#8069=IFCCLASSIFICATIONREFERENCE($,'23-39 13 11 11','Tunnel Shafts',#8068,$,$); -#8070=IFCCLASSIFICATIONREFERENCE($,'23-39 13 11 13','Tunnel Segments',#8068,$,$); -#8071=IFCCLASSIFICATIONREFERENCE($,'23-39 13 11 15','Tunnel Linings',#8068,$,$); -#8072=IFCCLASSIFICATIONREFERENCE($,'23-39 13 11 17','Tunnel Grouting',#8068,$,$); -#8073=IFCCLASSIFICATIONREFERENCE($,'23-39 13 11 17 11','Earth Stabilization Chemical Grouting',#8072,$,$); -#8074=IFCCLASSIFICATIONREFERENCE($,'23-39 13 11 17 13','Rock Seam Pressure Grouting',#8072,$,$); -#8075=IFCCLASSIFICATIONREFERENCE($,'23-39 13 11 17 15','Tunnel Liner Grouting',#8072,$,$); -#8076=IFCCLASSIFICATIONREFERENCE($,'23-39 13 11 19','Microtunneling',#8068,$,$); -#8077=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13','Bridges',#8067,$,$); -#8078=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 11','Prefabricated Bridges',#8077,$,$); -#8079=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 13','Bridge Beams',#8077,$,$); -#8080=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 15','Bridge Trusses',#8077,$,$); -#8081=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 17','Bridge Cable',#8077,$,$); -#8082=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 19','Bridge Bearings',#8077,$,$); -#8083=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 19 11','Fixed Bridge Bearings',#8082,$,$); -#8084=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 19 13','Expansion Bridge Bearings',#8082,$,$); -#8085=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 19 15','Multi Rotational Bridge Bearings',#8082,$,$); -#8086=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 21','Bridge Movable Mechanism',#8077,$,$); -#8087=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 23','Bridge Decking',#8077,$,$); -#8088=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 25','Bridge Drainage',#8077,$,$); -#8089=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 27','Bridge Safety Barriers',#8077,$,$); -#8090=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 27 11','Shock Absorbers',#8089,$,$); -#8091=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 27 13','Bridge Parapets',#8089,$,$); -#8092=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 27 15','Bridge Railings',#8089,$,$); -#8093=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 29','Bridge Expansion Joints',#8077,$,$); -#8094=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 29 11','Bridge Expansion Joint Assemblies',#8093,$,$); -#8095=IFCCLASSIFICATIONREFERENCE($,'23-39 15 00','Railways',#8033,$,$); -#8096=IFCCLASSIFICATIONREFERENCE($,'23-39 15 11','Railway Track Equipment',#8095,$,$); -#8097=IFCCLASSIFICATIONREFERENCE($,'23-39 15 11 11','Railway Ties',#8096,$,$); -#8098=IFCCLASSIFICATIONREFERENCE($,'23-39 15 11 11 11','Railway Concrete Ties',#8097,$,$); -#8099=IFCCLASSIFICATIONREFERENCE($,'23-39 15 11 11 13','Railway Wood Ties',#8097,$,$); -#8100=IFCCLASSIFICATIONREFERENCE($,'23-39 15 11 13','Railway Rails',#8096,$,$); -#8101=IFCCLASSIFICATIONREFERENCE($,'23-39 15 11 15','Railway Turnouts',#8096,$,$); -#8102=IFCCLASSIFICATIONREFERENCE($,'23-39 15 11 17','Railway Bumpers',#8096,$,$); -#8103=IFCCLASSIFICATIONREFERENCE($,'23-39 15 13','Railway Platform Components',#8095,$,$); -#8104=IFCCLASSIFICATIONREFERENCE($,'23-39 15 15','Railway Electrification Equipment',#8095,$,$); -#8105=IFCCLASSIFICATIONREFERENCE($,'23-39 15 15 11','Railway Surge Arresters',#8104,$,$); -#8106=IFCCLASSIFICATIONREFERENCE($,'23-39 15 15 13','Railway Traction Lines',#8104,$,$); -#8107=IFCCLASSIFICATIONREFERENCE($,'23-39 15 15 13 11','Railway Traction Line Pylons',#8106,$,$); -#8108=IFCCLASSIFICATIONREFERENCE($,'23-39 15 17','Railway Monitoring and Control',#8095,$,$); -#8109=IFCCLASSIFICATIONREFERENCE($,'23-39 15 17 11','Railway Signaling Devices',#8108,$,$); -#8110=IFCCLASSIFICATIONREFERENCE($,'23-39 15 17 13','Railway Control Instrumentation',#8108,$,$); -#8111=IFCCLASSIFICATIONREFERENCE($,'23-39 15 19','Railway Locomotives',#8095,$,$); -#8112=IFCCLASSIFICATIONREFERENCE($,'23-39 15 19 11','Railway Diesel Locomotives',#8111,$,$); -#8113=IFCCLASSIFICATIONREFERENCE($,'23-39 15 19 13','Railway Electric Locomotives',#8111,$,$); -#8114=IFCCLASSIFICATIONREFERENCE($,'23-39 15 21','Railway Cars',#8095,$,$); -#8115=IFCCLASSIFICATIONREFERENCE($,'23-39 15 21 11','Railway Passenger Cars',#8114,$,$); -#8116=IFCCLASSIFICATIONREFERENCE($,'23-39 15 21 13','Railway Sleeper Cars',#8114,$,$); -#8117=IFCCLASSIFICATIONREFERENCE($,'23-39 15 21 15','Railway Baggage Cars',#8114,$,$); -#8118=IFCCLASSIFICATIONREFERENCE($,'23-39 15 21 17','Railway Diner Cars',#8114,$,$); -#8119=IFCCLASSIFICATIONREFERENCE($,'23-39 15 21 19','Railway Freight Cars',#8114,$,$); -#8120=IFCCLASSIFICATIONREFERENCE($,'23-39 15 21 19 11','Railway Box Cars',#8119,$,$); -#8121=IFCCLASSIFICATIONREFERENCE($,'23-39 15 21 19 13','Railway Coal Cars',#8119,$,$); -#8122=IFCCLASSIFICATIONREFERENCE($,'23-39 15 21 19 15','Railway Vehicle Carrier Cars',#8119,$,$); -#8123=IFCCLASSIFICATIONREFERENCE($,'23-39 15 21 21','Railway Tanker Cars',#8114,$,$); -#8124=IFCCLASSIFICATIONREFERENCE($,'23-39 15 21 23','Railway Car Equipment',#8114,$,$); -#8125=IFCCLASSIFICATIONREFERENCE($,'23-39 15 21 23 11','Railway Car Bumpers',#8124,$,$); -#8126=IFCCLASSIFICATIONREFERENCE($,'23-39 15 21 23 13','Railway Car Electrical Connectors',#8124,$,$); -#8127=IFCCLASSIFICATIONREFERENCE($,'23-39 17 00','Funiculars',#8033,$,$); -#8128=IFCCLASSIFICATIONREFERENCE($,'23-39 17 11','Cable Trams',#8127,$,$); -#8129=IFCCLASSIFICATIONREFERENCE($,'23-39 17 13','Cable Cars',#8127,$,$); -#8130=IFCCLASSIFICATIONREFERENCE($,'23-39 17 15','Funicular Cable Rails',#8127,$,$); -#8131=IFCCLASSIFICATIONREFERENCE($,'23-39 17 17','Funicular Cables',#8127,$,$); -#8132=IFCCLASSIFICATIONREFERENCE($,'23-39 17 19','Aerial Tramways',#8127,$,$); -#8133=IFCCLASSIFICATIONREFERENCE($,'23-39 17 21','Chair Lifts',#8127,$,$); -#8134=IFCCLASSIFICATIONREFERENCE($,'23-39 17 23','Ski Lifts',#8127,$,$); -#8135=IFCCLASSIFICATIONREFERENCE($,'23-39 17 23 11','Ski Pole Lifts',#8134,$,$); -#8136=IFCCLASSIFICATIONREFERENCE($,'23-39 17 23 13','Ski Chair Lifts',#8134,$,$); -#8137=IFCCLASSIFICATIONREFERENCE($,'23-39 19 00','Aviation Equipment',#8033,$,$); -#8138=IFCCLASSIFICATIONREFERENCE($,'23-39 19 11','Aviation Monitoring and Control',#8137,$,$); -#8139=IFCCLASSIFICATIONREFERENCE($,'23-39 19 11 11','Approach Indication Equipment',#8138,$,$); -#8140=IFCCLASSIFICATIONREFERENCE($,'23-39 19 11 13','Aviation Monitoring Equipment',#8138,$,$); -#8141=IFCCLASSIFICATIONREFERENCE($,'23-39 19 11 13 11','Aviation Windsocks',#8140,$,$); -#8142=IFCCLASSIFICATIONREFERENCE($,'23-39 19 13','Aviation Barriers',#8137,$,$); -#8143=IFCCLASSIFICATIONREFERENCE($,'23-39 19 13 11','Jet Blast Barriers',#8142,$,$); -#8144=IFCCLASSIFICATIONREFERENCE($,'23-39 19 13 13','Aviation Sound Barriers',#8142,$,$); -#8145=IFCCLASSIFICATIONREFERENCE($,'23-39 21 00','Marine Construction Waterways and Seaways',#8033,$,$); -#8146=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11','Navigation Facilities',#8145,$,$); -#8147=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 11','Components',#8146,$,$); -#8148=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 11 11','Mooring Posts',#8147,$,$); -#8149=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 11 13','Boat Fenders',#8147,$,$); -#8150=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 13','Canal Locks',#8146,$,$); -#8151=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 13 11','Canal Lock Gates',#8150,$,$); -#8152=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 13 11 11','Canal Hydraulic Gates',#8151,$,$); -#8153=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 13 11 13','Canal High Pressure Gates',#8151,$,$); -#8154=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 13 11 15','Canal Hinged Leaf Gates',#8151,$,$); -#8155=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 13 11 17','Canal Radial Gates',#8151,$,$); -#8156=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 13 11 19','Canal Slide Gates',#8151,$,$); -#8157=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 13 11 21','Canal Sluice Gates',#8151,$,$); -#8158=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 13 11 23','Canal Spillway Crest Gates',#8151,$,$); -#8159=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 13 11 25','Canal Vertical Lift Gates',#8151,$,$); -#8160=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 13 13','Canal Hydraulic Valves',#8150,$,$); -#8161=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 13 13 11','Canal Butterfly Valves',#8160,$,$); -#8162=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 13 13 13','Canal Regulating Valves',#8160,$,$); -#8163=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 15','Piers and Docks',#8146,$,$); -#8164=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 15 11','Floating Docks',#8163,$,$); -#8165=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 15 13','Dock Loading Ramps',#8163,$,$); -#8166=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 17','Pontoons',#8146,$,$); -#8167=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 19','Jetties',#8146,$,$); -#8168=IFCCLASSIFICATIONREFERENCE($,'23-39 21 13','Waterflow Controls',#8145,$,$); -#8169=IFCCLASSIFICATIONREFERENCE($,'23-39 21 13 11','Reservoirs',#8168,$,$); -#8170=IFCCLASSIFICATIONREFERENCE($,'23-39 21 13 13','Dams, Dikes',#8168,$,$); -#8171=IFCCLASSIFICATIONREFERENCE($,'23-39 21 13 15','Weirs',#8168,$,$); -#8172=IFCCLASSIFICATIONREFERENCE($,'23-39 21 13 17','Barrages',#8168,$,$); -#8173=IFCCLASSIFICATIONREFERENCE($,'23-39 21 13 19','Bifurcation Panels',#8168,$,$); -#8174=IFCCLASSIFICATIONREFERENCE($,'23-39 21 13 21','Manifolds',#8168,$,$); -#8175=IFCCLASSIFICATIONREFERENCE($,'23-39 21 13 23','Penstocks and Sluice Gate',#8168,$,$); -#8176=IFCCLASSIFICATIONREFERENCE($,'23-39 21 13 25','Trash Rakes',#8168,$,$); -#8177=IFCCLASSIFICATIONREFERENCE($,'23-39 21 15','Breakwater Products',#8145,$,$); -#8178=IFCCLASSIFICATIONREFERENCE($,'23-39 21 15 11','Bulkheads',#8177,$,$); -#8179=IFCCLASSIFICATIONREFERENCE($,'23-39 21 15 13','Seawalls',#8177,$,$); -#8180=IFCCLASSIFICATIONREFERENCE($,'23-39 21 15 15','Moles and Breakwater',#8177,$,$); -#8181=IFCCLASSIFICATIONREFERENCE($,'23-39 21 15 17','Groins',#8177,$,$); -#8182=IFCCLASSIFICATIONREFERENCE($,'23-39 21 17','Marine Monitoring and Control',#8145,$,$); -#8183=IFCCLASSIFICATIONREFERENCE($,'23-39 21 17 11','Navigation Signs',#8182,$,$); -#8184=IFCCLASSIFICATIONREFERENCE($,'23-39 21 17 13','Navigation Lights',#8182,$,$); -#8185=IFCCLASSIFICATIONREFERENCE($,'23-39 21 17 15','Navigation Monitoring Equipment',#8182,$,$); -#8186=IFCCLASSIFICATIONREFERENCE($,'23-39 23 00','Electrical Utility Equipment',#8033,$,$); -#8187=IFCCLASSIFICATIONREFERENCE($,'23-39 23 11','Electrical Transmission Equipment',#8186,$,$); -#8188=IFCCLASSIFICATIONREFERENCE($,'23-39 23 11 11','Electrical Utility Poles',#8187,$,$); -#8189=IFCCLASSIFICATIONREFERENCE($,'23-39 23 11 13','Electrical Utility Towers',#8187,$,$); -#8190=IFCCLASSIFICATIONREFERENCE($,'23-39 25 00','Natural Gas Utility Equipment',#8033,$,$); -#8191=IFCCLASSIFICATIONREFERENCE($,'23-39 25 11','Natural Gas Utility Pipeline Equipment',#8190,$,$); -#8192=IFCCLASSIFICATIONREFERENCE($,'23-39 27 00','Water Utility Equipment',#8033,$,$); -#8193=IFCCLASSIFICATIONREFERENCE($,'23-39 27 11','Water Utility Pipeline Equipment',#8192,$,$); -#8194=IFCCLASSIFICATIONREFERENCE($,'23-39 29 00','Waste Water Collection and Removal',#8033,$,$); -#8195=IFCCLASSIFICATIONREFERENCE($,'23-39 29 11','Waste Water Drains',#8194,$,$); -#8196=IFCCLASSIFICATIONREFERENCE($,'23-39 29 11 11','Waste Water French Drains',#8195,$,$); -#8197=IFCCLASSIFICATIONREFERENCE($,'23-39 29 11 13','Waste Water Storm Drain',#8195,$,$); -#8198=IFCCLASSIFICATIONREFERENCE($,'23-39 29 11 13 11','Manhole (Goes in Prefab Concrete)',#8197,$,$); -#8199=IFCCLASSIFICATIONREFERENCE($,'23-39 29 11 13 13','Manhole Cover',#8197,$,$); -#8200=IFCCLASSIFICATIONREFERENCE($,'23-39 29 11 13 15','Manhole Ladder',#8197,$,$); -#8201=IFCCLASSIFICATIONREFERENCE($,'23-39 29 11 13 17','Manhole Rung',#8197,$,$); -#8202=IFCCLASSIFICATIONREFERENCE($,'23-39 29 11 15','Waste Water Drainage Pipes, Couplings, Collectors',#8195,$,$); -#8203=IFCCLASSIFICATIONREFERENCE($,'23-39 29 11 17','Wastewater Pipework Access Fittings',#8195,$,$); -#8204=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13','Waste Water Subdrainage',#8194,$,$); -#8205=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13 11','Geocomposite Drains',#8204,$,$); -#8206=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13 13','Geotextile Subsurface Drainage Filtration',#8204,$,$); -#8207=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13 15','Pipe Underdrain and Pavement Base Drain',#8204,$,$); -#8208=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13 17','Subgrade Drains',#8204,$,$); -#8209=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13 19','Surface Water Drainage Systems',#8204,$,$); -#8210=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13 19 11','Surface Water Catch Basins, Grates, and Frames',#8209,$,$); -#8211=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13 19 13','Combination Storm Drain and Underdrain Inlets',#8209,$,$); -#8212=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13 19 15','Storm Drainage Manholes, Frames, and Covers',#8209,$,$); -#8213=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13 19 17','Surface Water Retention Chambers',#8209,$,$); -#8214=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13 21','Storm Water Ponds and Reservoirs',#8204,$,$); -#8215=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13 21 19','Surface Water Retention Basins',#8214,$,$); -#8216=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13 21 21','Storm Water Pond Covers',#8214,$,$); -#8217=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13 21 23','Storm Water Pond Liners',#8214,$,$); -#8218=IFCCLASSIFICATIONREFERENCE($,'23-39 29 15','Waste Water Channels, Gullies, Gratings, Covers',#8194,$,$); -#8219=IFCCLASSIFICATIONREFERENCE($,'23-39 31 00','Packaged Waste Water Treatment',#8033,$,$); -#8220=IFCCLASSIFICATIONREFERENCE($,'23-39 31 11','Packaged Stations',#8219,$,$); -#8221=IFCCLASSIFICATIONREFERENCE($,'23-39 31 11 11','Packaged Pumping Stations',#8220,$,$); -#8222=IFCCLASSIFICATIONREFERENCE($,'23-39 31 11 13','Packaged Lift Stations',#8220,$,$); -#8223=IFCCLASSIFICATIONREFERENCE($,'23-39 31 13','Packaged Sewage Treatment Plants',#8219,$,$); -#8224=IFCCLASSIFICATIONREFERENCE($,'23-39 33 00','Water and Waste Water Preliminary Treatment Equipment',#8033,$,$); -#8225=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11','Screening Equipment',#8224,$,$); -#8226=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 11','Climber-type Bar Screens',#8225,$,$); -#8227=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 13','Chain-and-Rage Bar Screens',#8225,$,$); -#8228=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 15','Flexible Rake Bar Screens',#8225,$,$); -#8229=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 17','Catenary Bar Screens',#8225,$,$); -#8230=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 19','Continuous Belt Screens',#8225,$,$); -#8231=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 21','Cylindrical Bar Screens',#8225,$,$); -#8232=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 23','Step Screens',#8225,$,$); -#8233=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 25','Rotary Drum Screens',#8225,$,$); -#8234=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 27','Spiral Screens',#8225,$,$); -#8235=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 29','Band Screens',#8225,$,$); -#8236=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 31','Disc Screens',#8225,$,$); -#8237=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 33','Traveling Screens',#8225,$,$); -#8238=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 35','Perforated Plate Screens',#8225,$,$); -#8239=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 37','Wedge Wire Screens',#8225,$,$); -#8240=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 39','Element Screens',#8225,$,$); -#8241=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 41','Trash Raking Equipment',#8225,$,$); -#8242=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 43','Screenings Washing and Compacting Equipment',#8225,$,$); -#8243=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 45','Vacuum Screenings Conveying Equipment',#8225,$,$); -#8244=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 47','Screenings Storage Containers',#8225,$,$); -#8245=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 49','Septage Receiving Equipment',#8225,$,$); -#8246=IFCCLASSIFICATIONREFERENCE($,'23-39 33 13','Grit Removal and Handling Equipment',#8224,$,$); -#8247=IFCCLASSIFICATIONREFERENCE($,'23-39 33 13 11','Chain-and-Bucket Grit Removal Equipment',#8246,$,$); -#8248=IFCCLASSIFICATIONREFERENCE($,'23-39 33 13 13','Chain-and-Flight Grit Removal Equipment',#8246,$,$); -#8249=IFCCLASSIFICATIONREFERENCE($,'23-39 33 13 15','Vortex Grit Removal Equipment',#8246,$,$); -#8250=IFCCLASSIFICATIONREFERENCE($,'23-39 33 13 17','Cyclone Degritters',#8246,$,$); -#8251=IFCCLASSIFICATIONREFERENCE($,'23-39 33 13 19','Aerated Grit Removal Equipment',#8246,$,$); -#8252=IFCCLASSIFICATIONREFERENCE($,'23-39 33 13 21','Inline Baffled Grit Removal Equipment',#8246,$,$); -#8253=IFCCLASSIFICATIONREFERENCE($,'23-39 33 13 23','Traveling Bridge Grit Removal Equipment',#8246,$,$); -#8254=IFCCLASSIFICATIONREFERENCE($,'23-39 33 13 25','Grit Classifying and Washing Equipment',#8246,$,$); -#8255=IFCCLASSIFICATIONREFERENCE($,'23-39 33 13 27','Grit Storage Containers',#8246,$,$); -#8256=IFCCLASSIFICATIONREFERENCE($,'23-39 33 15','Grinding and Shredding Equipment',#8224,$,$); -#8257=IFCCLASSIFICATIONREFERENCE($,'23-39 33 15 11','Macerators',#8256,$,$); -#8258=IFCCLASSIFICATIONREFERENCE($,'23-39 33 15 13','Comminutors',#8256,$,$); -#8259=IFCCLASSIFICATIONREFERENCE($,'23-39 33 15 15','Inline Grinders',#8256,$,$); -#8260=IFCCLASSIFICATIONREFERENCE($,'23-39 33 15 17','Open-Channel Grinders',#8256,$,$); -#8261=IFCCLASSIFICATIONREFERENCE($,'23-39 33 15 19','Modular Grinding-Screening-Compacting Equipment',#8256,$,$); -#8262=IFCCLASSIFICATIONREFERENCE($,'23-39 33 17','Oil and Grease Separation and Removal Equipment',#8224,$,$); -#8263=IFCCLASSIFICATIONREFERENCE($,'23-39 33 17 11','Coalescing Oil-Water Separators',#8262,$,$); -#8264=IFCCLASSIFICATIONREFERENCE($,'23-39 33 17 13','API Oil-Water Separators',#8262,$,$); -#8265=IFCCLASSIFICATIONREFERENCE($,'23-39 33 17 15','Grease Traps',#8262,$,$); -#8266=IFCCLASSIFICATIONREFERENCE($,'23-39 33 17 17','Dissolved Air Flotation Grease and Oil Separation Equipment',#8262,$,$); -#8267=IFCCLASSIFICATIONREFERENCE($,'23-39 33 17 19','Helical Scum Skimming and Removal Equipment',#8262,$,$); -#8268=IFCCLASSIFICATIONREFERENCE($,'23-39 33 17 21','Tipping Trough Scum Skimming and Removal Equipment',#8262,$,$); -#8269=IFCCLASSIFICATIONREFERENCE($,'23-39 33 17 23','Chain and Flight Scum Collection and Removal Equipment',#8262,$,$); -#8270=IFCCLASSIFICATIONREFERENCE($,'23-39 33 17 25','Floating Scum Skimming and Removal Equipment',#8262,$,$); -#8271=IFCCLASSIFICATIONREFERENCE($,'23-39 35 00','Water and Wastewater Chemical Feed Equipment',#8033,$,$); -#8272=IFCCLASSIFICATIONREFERENCE($,'23-39 35 11','Gas Chemical Feed Equipment',#8271,$,$); -#8273=IFCCLASSIFICATIONREFERENCE($,'23-39 35 11 11','Chlorine Gas Feed Equipment',#8272,$,$); -#8274=IFCCLASSIFICATIONREFERENCE($,'23-39 35 11 13','Sulfur Dioxide Gas Feed Equipment',#8272,$,$); -#8275=IFCCLASSIFICATIONREFERENCE($,'23-39 35 11 15','Ammonia Gas Feed Equipment',#8272,$,$); -#8276=IFCCLASSIFICATIONREFERENCE($,'23-39 35 11 17','Gas Storage, Weighing, and Leak Detection Equipment',#8272,$,$); -#8277=IFCCLASSIFICATIONREFERENCE($,'23-39 35 11 19','Chlorine Dioxide Reactors',#8272,$,$); -#8278=IFCCLASSIFICATIONREFERENCE($,'23-39 35 11 21','Carbon Dioxide Gas Feed Equipment',#8272,$,$); -#8279=IFCCLASSIFICATIONREFERENCE($,'23-39 35 11 23','Ozone Generating and Feed Equipment',#8272,$,$); -#8280=IFCCLASSIFICATIONREFERENCE($,'23-39 35 11 25','Liquid Oxygen Storage and Feed Equipment',#8272,$,$); -#8281=IFCCLASSIFICATIONREFERENCE($,'23-39 35 11 27','Cleaning Requirements for Oxygen Service',#8272,$,$); -#8282=IFCCLASSIFICATIONREFERENCE($,'23-39 35 11 29','Gas Chemical Feed Accessories and Safety Equipment',#8272,$,$); -#8283=IFCCLASSIFICATIONREFERENCE($,'23-39 35 13','Liquid Chemical Feed Equipment',#8271,$,$); -#8284=IFCCLASSIFICATIONREFERENCE($,'23-39 35 13 11','Sodium Hypochlorite Generating Equipment',#8283,$,$); -#8285=IFCCLASSIFICATIONREFERENCE($,'23-39 35 13 13','Liquid Chemical Weighing Equipment',#8283,$,$); -#8286=IFCCLASSIFICATIONREFERENCE($,'23-39 35 13 15','Polymer Blending and Feed Equipment',#8283,$,$); -#8287=IFCCLASSIFICATIONREFERENCE($,'23-39 35 13 17','Diaphragm-type Metering Pumps',#8283,$,$); -#8288=IFCCLASSIFICATIONREFERENCE($,'23-39 35 13 19','Peristaltic Metering Pumps',#8283,$,$); -#8289=IFCCLASSIFICATIONREFERENCE($,'23-39 35 13 21','Progressing Cavity Metering Pumps',#8283,$,$); -#8290=IFCCLASSIFICATIONREFERENCE($,'23-39 35 13 23','Lobe Metering Pumps',#8283,$,$); -#8291=IFCCLASSIFICATIONREFERENCE($,'23-39 35 13 25','Drum Pumps',#8283,$,$); -#8292=IFCCLASSIFICATIONREFERENCE($,'23-39 35 13 27','Liquid Chemical Transfer Pumps',#8283,$,$); -#8293=IFCCLASSIFICATIONREFERENCE($,'23-39 35 13 29','Liquid Chemical Diffusers',#8283,$,$); -#8294=IFCCLASSIFICATIONREFERENCE($,'23-39 35 13 31','Liquid Chemical Feed Accessories and Safety Equipment',#8283,$,$); -#8295=IFCCLASSIFICATIONREFERENCE($,'23-39 35 15','Dry Chemical Feed Equipment',#8271,$,$); -#8296=IFCCLASSIFICATIONREFERENCE($,'23-39 35 15 11','Storage Silos',#8295,$,$); -#8297=IFCCLASSIFICATIONREFERENCE($,'23-39 35 15 13','Dry Chemical Weighing Equipment',#8295,$,$); -#8298=IFCCLASSIFICATIONREFERENCE($,'23-39 35 15 15','Volumetric Feed Equipment',#8295,$,$); -#8299=IFCCLASSIFICATIONREFERENCE($,'23-39 35 15 17','Gravimetric Feed Equipment',#8295,$,$); -#8300=IFCCLASSIFICATIONREFERENCE($,'23-39 35 15 19','Lime Slaking Equipment',#8295,$,$); -#8301=IFCCLASSIFICATIONREFERENCE($,'23-39 35 15 21','Chemical Tablet Feeding Equipment',#8295,$,$); -#8302=IFCCLASSIFICATIONREFERENCE($,'23-39 35 15 23','Dry Chemical Feed Accessories and Safety Equipment',#8295,$,$); -#8303=IFCCLASSIFICATIONREFERENCE($,'23-39 37 00','Water and Wastewater Clarification and Mixing Equipment',#8033,$,$); -#8304=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11','Mixing Equipment',#8303,$,$); -#8305=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 11','Rapid Mixers',#8304,$,$); -#8306=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 13','Inline Blender-type Rapid Mixers',#8304,$,$); -#8307=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 15','Induction-type Rapid Mixing Equipment',#8304,$,$); -#8308=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 17','Inline Static Mixers',#8304,$,$); -#8309=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 19','Mixing Equipment',#8304,$,$); -#8310=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 21','Submersible Mixers',#8304,$,$); -#8311=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 23','Floating Mechanical Mixers',#8304,$,$); -#8312=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 25','Paddle Mixers',#8304,$,$); -#8313=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 27','Pin Mixers',#8304,$,$); -#8314=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 29','Vertical Reel Flocculation Equipment',#8304,$,$); -#8315=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 31','Horizontal Reel Flocculation Equipment',#8304,$,$); -#8316=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 33','Vertical Turbine Flocculation Equipment',#8304,$,$); -#8317=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 35','Walking-beam Flocculation Equipment',#8304,$,$); -#8318=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 37','Horizontal Oscillating Flocculation Equipment',#8304,$,$); -#8319=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 39','Top-entering Tank Mixers',#8304,$,$); -#8320=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 41','Side-entry Tank Mixers',#8304,$,$); -#8321=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 43','Portable Tank Mixers',#8304,$,$); -#8322=IFCCLASSIFICATIONREFERENCE($,'23-39 37 13','Clarifier Equipment',#8303,$,$); -#8323=IFCCLASSIFICATIONREFERENCE($,'23-39 37 13 11','Chain-and-Flight Clarifier Equipment',#8322,$,$); -#8324=IFCCLASSIFICATIONREFERENCE($,'23-39 37 13 13','Traveling Bridge Clarifier Equipment',#8322,$,$); -#8325=IFCCLASSIFICATIONREFERENCE($,'23-39 37 13 15','Differential Head Clarifier Equipment',#8322,$,$); -#8326=IFCCLASSIFICATIONREFERENCE($,'23-39 37 13 17','Oscillating Scraper-type Clarifier Equipment',#8322,$,$); -#8327=IFCCLASSIFICATIONREFERENCE($,'23-39 37 13 19','Circular Clarifier Equipment',#8322,$,$); -#8328=IFCCLASSIFICATIONREFERENCE($,'23-39 37 13 21','Solids Contact Clarifier Equipment',#8322,$,$); -#8329=IFCCLASSIFICATIONREFERENCE($,'23-39 37 13 23','Flocculating Clarifier, Pulsating Sludge Blanket Type',#8322,$,$); -#8330=IFCCLASSIFICATIONREFERENCE($,'23-39 37 13 25','Dissolved Air Flotation Equipment for Water Treatment',#8322,$,$); -#8331=IFCCLASSIFICATIONREFERENCE($,'23-39 37 13 27','Ballasted High-rate Clarifier Equipment',#8322,$,$); -#8332=IFCCLASSIFICATIONREFERENCE($,'23-39 37 13 29','High rate Clarification/Thickening Equipment',#8322,$,$); -#8333=IFCCLASSIFICATIONREFERENCE($,'23-39 37 13 31','Tube Settlers',#8322,$,$); -#8334=IFCCLASSIFICATIONREFERENCE($,'23-39 37 13 33','Lined Plate Settlers',#8322,$,$); -#8335=IFCCLASSIFICATIONREFERENCE($,'23-39 37 15','Sediment Removal Equipment',#8303,$,$); -#8336=IFCCLASSIFICATIONREFERENCE($,'23-39 37 15 11','Tipping Sediment Flushing Tanks',#8335,$,$); -#8337=IFCCLASSIFICATIONREFERENCE($,'23-39 37 15 13','Flushing Gates',#8335,$,$); -#8338=IFCCLASSIFICATIONREFERENCE($,'23-39 37 15 15','Water Cannon',#8335,$,$); -#8339=IFCCLASSIFICATIONREFERENCE($,'23-39 39 00','Water and Wastewater Secondary Treatment Equipment',#8033,$,$); -#8340=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11','Air and Gas Diffusion Equipment',#8339,$,$); -#8341=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 11','Fixed Mechanical Aerators',#8340,$,$); -#8342=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 13','Floating Mechanical Aerators',#8340,$,$); -#8343=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 15','Submersible Aspirating Aerator Equipment',#8340,$,$); -#8344=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 17','Jet Aeration Equipment',#8340,$,$); -#8345=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 19','Coarse Bubble Diffusers',#8340,$,$); -#8346=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 21','Swing-type Channel Aeration Equipment',#8340,$,$); -#8347=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 23','Shear Box Diffusers',#8340,$,$); -#8348=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 25','Flexible Membrane Tube Diffusers',#8340,$,$); -#8349=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 27','Flexible Membrane Disc Diffusers',#8340,$,$); -#8350=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 29','Ceramic Disc Fine Bubble Diffusers',#8340,$,$); -#8351=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 31','Floating Membrane Diffusers',#8340,$,$); -#8352=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 33','Membrane Diffusers',#8340,$,$); -#8353=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 35','Cascading Aerators',#8340,$,$); -#8354=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 37','Pure-oxygen Generating Equipment',#8340,$,$); -#8355=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13','Biological Treatment Systems',#8339,$,$); -#8356=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13 11','Rotating Biological Contactors',#8355,$,$); -#8357=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13 13','Trickling Filter Rotary Distributor Equipment',#8355,$,$); -#8358=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13 15','Trickling Filter Media',#8355,$,$); -#8359=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13 17','Bio-towers',#8355,$,$); -#8360=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13 19','Moving-bed Biological Reactors',#8355,$,$); -#8361=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13 21','Integrated Fixed-film Activated Sludge Equipment',#8355,$,$); -#8362=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13 23','Intermittent Sand Filters for Wastewater Treatment',#8355,$,$); -#8363=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13 25','Deep-bed Denitrification Filters',#8355,$,$); -#8364=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13 27','Biologically Activated Filters',#8355,$,$); -#8365=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13 29','Membrane Biological Reactors',#8355,$,$); -#8366=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13 31','Sequencing Batch Reactors',#8355,$,$); -#8367=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13 33','Oxidation Ditch Equipment',#8355,$,$); -#8368=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13 35','Vertical Loop Reactors',#8355,$,$); -#8369=IFCCLASSIFICATIONREFERENCE($,'23-39 41 00','Water and Wastewater Advanced Treatment Equipment',#8033,$,$); -#8370=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11','Filtration Equipment',#8369,$,$); -#8371=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 11','Filter Media',#8370,$,$); -#8372=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 13','Filter Surface Wash Agitators',#8370,$,$); -#8373=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 15','Filter Air Scour Equipment',#8370,$,$); -#8374=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 17','Wash Water Troughs',#8370,$,$); -#8375=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 19','Pressure Filters',#8370,$,$); -#8376=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 21','Gravity Filters',#8370,$,$); -#8377=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 23','High-rate Sand Filters',#8370,$,$); -#8378=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 25','Traveling Bridge Filters',#8370,$,$); -#8379=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 27','Microfiltration and Ultrafiltration Membrane Equipment',#8370,$,$); -#8380=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 29','Disc Cloth Filters',#8370,$,$); -#8381=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 31','Rotary Drum Cloth Filters',#8370,$,$); -#8382=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 33','Automatic Backwash Cloth Filter Equipment',#8370,$,$); -#8383=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 35','Cartridge Filters',#8370,$,$); -#8384=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 37','Bag Filters',#8370,$,$); -#8385=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 39','Automatic Straining Equipment',#8370,$,$); -#8386=IFCCLASSIFICATIONREFERENCE($,'23-39 41 13','Demineralization Equipment',#8369,$,$); -#8387=IFCCLASSIFICATIONREFERENCE($,'23-39 41 13 11','Ion-exchange Vessel Media',#8386,$,$); -#8388=IFCCLASSIFICATIONREFERENCE($,'23-39 41 13 13','Electrodialysis Reversal Equipment',#8386,$,$); -#8389=IFCCLASSIFICATIONREFERENCE($,'23-39 41 13 15','Reverse Osmosis and Nanofiltration Membrane Equipment',#8386,$,$); -#8390=IFCCLASSIFICATIONREFERENCE($,'23-39 41 13 17','Multiple-effect Distillation Equipment',#8386,$,$); -#8391=IFCCLASSIFICATIONREFERENCE($,'23-39 41 13 19','Desalination Mechanical Vapor Compression Equipment',#8386,$,$); -#8392=IFCCLASSIFICATIONREFERENCE($,'23-39 41 13 21','Desalination Thermal Vapor Compression Equipment',#8386,$,$); -#8393=IFCCLASSIFICATIONREFERENCE($,'23-39 41 13 23','Desalination Multi-stage Flash Equipment',#8386,$,$); -#8394=IFCCLASSIFICATIONREFERENCE($,'23-39 41 13 25','Desalination Falling Film Evaporators',#8386,$,$); -#8395=IFCCLASSIFICATIONREFERENCE($,'23-39 41 13 27','Desalination Rising Film Evaporators',#8386,$,$); -#8396=IFCCLASSIFICATIONREFERENCE($,'23-39 41 13 29','Desalination Forced-circulation Crystallizing Equipment',#8386,$,$); -#8397=IFCCLASSIFICATIONREFERENCE($,'23-39 41 13 31','Desalination Spray Dry Evaporation Equipment',#8386,$,$); -#8398=IFCCLASSIFICATIONREFERENCE($,'23-39 41 13 33','Demineralization Energy Recovery Equipment',#8386,$,$); -#8399=IFCCLASSIFICATIONREFERENCE($,'23-39 41 15','Ultraviolet Equipment',#8369,$,$); -#8400=IFCCLASSIFICATIONREFERENCE($,'23-39 41 15 11','Closed-vessel Low-pressure/Low-intensity Ultraviolet Treatment Equipment',#8399,$,$); -#8401=IFCCLASSIFICATIONREFERENCE($,'23-39 41 15 13','Closed-vessel Low-pressure/High-intensity Ultraviolet Treatment Equipment',#8399,$,$); -#8402=IFCCLASSIFICATIONREFERENCE($,'23-39 41 15 15','Closed-vessel Medium-pressure Ultraviolet Treatment Equipment',#8399,$,$); -#8403=IFCCLASSIFICATIONREFERENCE($,'23-39 41 15 17','Open-channel Low-pressure/Low-intensity Ultraviolet Treatment Equipment',#8399,$,$); -#8404=IFCCLASSIFICATIONREFERENCE($,'23-39 41 15 19','Open-channel Low-pressure/High-intensity Ultraviolet Treatment Equipment',#8399,$,$); -#8405=IFCCLASSIFICATIONREFERENCE($,'23-39 41 15 21','Open-channel Medium-pressure Ultraviolet Treatment Equipment',#8399,$,$); -#8406=IFCCLASSIFICATIONREFERENCE($,'23-39 43 00','Water and Wastewater Residuals Handling and Treatment',#8033,$,$); -#8407=IFCCLASSIFICATIONREFERENCE($,'23-39 43 11','Residuals Thickening Equipment',#8406,$,$); -#8408=IFCCLASSIFICATIONREFERENCE($,'23-39 43 11 11','Circular Gravity Thickeners',#8407,$,$); -#8409=IFCCLASSIFICATIONREFERENCE($,'23-39 43 11 13','Gravity Belt Thickeners',#8407,$,$); -#8410=IFCCLASSIFICATIONREFERENCE($,'23-39 43 11 15','Dissolved Air Flotation Thickening Equipment',#8407,$,$); -#8411=IFCCLASSIFICATIONREFERENCE($,'23-39 43 11 17','Rotary Drum Thickening Equipment',#8407,$,$); -#8412=IFCCLASSIFICATIONREFERENCE($,'23-39 43 11 19','Centrifuge Thickening Equipment',#8407,$,$); -#8413=IFCCLASSIFICATIONREFERENCE($,'23-39 43 11 21','Disc Thickeners',#8407,$,$); -#8414=IFCCLASSIFICATIONREFERENCE($,'23-39 43 11 23','Thickening Screw Press',#8407,$,$); -#8415=IFCCLASSIFICATIONREFERENCE($,'23-39 43 11 25','Scum Concentrator Equipment',#8407,$,$); -#8416=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13','Residuals Stabilization',#8406,$,$); -#8417=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 11','Digester Covers and Appurtenances',#8416,$,$); -#8418=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 11 11','Fixed Covers',#8417,$,$); -#8419=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 11 13','Floating Covers',#8417,$,$); -#8420=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 11 15','Gasholder Covers',#8417,$,$); -#8421=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 13','Radial Beam Fixed Digester Covers',#8416,$,$); -#8422=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 15','Dual Deck Truss-type Fixed Digester Covers',#8416,$,$); -#8423=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 17','Radial Beam Floating Digester Covers',#8416,$,$); -#8424=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 19','Dual Deck Truss-type Floating Digester Covers',#8416,$,$); -#8425=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 21','Radial Beam Floating Gas-holding Digester Covers',#8416,$,$); -#8426=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 23','Dual Deck Truss-type Floating Gas-holding Digester Covers',#8416,$,$); -#8427=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 25','Digester Appurtenances',#8416,$,$); -#8428=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 27','Aerobic Digester Aeration Equipment',#8416,$,$); -#8429=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 29','Autothermal Thermophilic Aerobic Digestion Equipment',#8416,$,$); -#8430=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 31','Egg-shaped Digesters',#8416,$,$); -#8431=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 33','Confined Gas Mixing System',#8416,$,$); -#8432=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 35','Digester Heating Equipment',#8416,$,$); -#8433=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 37','Residuals Pasteurization Equipment',#8416,$,$); -#8434=IFCCLASSIFICATIONREFERENCE($,'23-39 43 15','Residuals Dewatering Equipment',#8406,$,$); -#8435=IFCCLASSIFICATIONREFERENCE($,'23-39 43 15 11','Vacuum Filters',#8434,$,$); -#8436=IFCCLASSIFICATIONREFERENCE($,'23-39 43 15 13','Belt Filter Presses',#8434,$,$); -#8437=IFCCLASSIFICATIONREFERENCE($,'23-39 43 15 15','Plate-and-Frame Filter Presses',#8434,$,$); -#8438=IFCCLASSIFICATIONREFERENCE($,'23-39 43 15 17','Rotary Presses',#8434,$,$); -#8439=IFCCLASSIFICATIONREFERENCE($,'23-39 43 15 19','Screw Presses',#8434,$,$); -#8440=IFCCLASSIFICATIONREFERENCE($,'23-39 43 15 21','Dewatering Centrifuges',#8434,$,$); -#8441=IFCCLASSIFICATIONREFERENCE($,'23-39 43 15 23','Belt Dryers',#8434,$,$); -#8442=IFCCLASSIFICATIONREFERENCE($,'23-39 43 15 25','Direct-heat Residuals Drying Equipment',#8434,$,$); -#8443=IFCCLASSIFICATIONREFERENCE($,'23-39 43 15 27','Indirect-heat Residuals Drying Equipment',#8434,$,$); -#8444=IFCCLASSIFICATIONREFERENCE($,'23-39 43 17','Thermal Treatment of Residuals',#8406,$,$); -#8445=IFCCLASSIFICATIONREFERENCE($,'23-39 43 17 11','Multiple-hearth Sludge Incinerators',#8444,$,$); -#8446=IFCCLASSIFICATIONREFERENCE($,'23-39 43 17 13','Fluidized-bed Sludge Incinerators',#8444,$,$); -#8447=IFCCLASSIFICATIONREFERENCE($,'23-39 43 17 15','Ash Handling Equipment',#8444,$,$); -#8448=IFCCLASSIFICATIONREFERENCE($,'23-39 43 17 17','Recuperative Air Preheating Equipment',#8444,$,$); -#8449=IFCCLASSIFICATIONREFERENCE($,'23-39 43 17 19','Regenerative Thermal Oxidizers',#8444,$,$); -#8450=IFCCLASSIFICATIONREFERENCE($,'23-39 43 17 21','Waste Heat Recovery Boilers',#8444,$,$); -#8451=IFCCLASSIFICATIONREFERENCE($,'23-39 43 17 23','Waste Heat Recovery Heat Exchangers',#8444,$,$); -#8452=IFCCLASSIFICATIONREFERENCE($,'23-39 43 17 25','Thermal Oxidation Equipment',#8444,$,$); -#8453=IFCCLASSIFICATIONREFERENCE($,'23-39 45 00','Septic System Equipment',#8033,$,$); -#8454=IFCCLASSIFICATIONREFERENCE($,'23-39 45 11','Liquid Waste Treatment',#8453,$,$); -#8455=IFCCLASSIFICATIONREFERENCE($,'23-39 45 11 11','Liquid Waste Decanter',#8454,$,$); -#8456=IFCCLASSIFICATIONREFERENCE($,'23-39 45 11 13','Bacterial Filter Tanks',#8454,$,$); -#8457=IFCCLASSIFICATIONREFERENCE($,'23-39 45 11 15','Liquid Waste Decanters',#8454,$,$); -#8458=IFCCLASSIFICATIONREFERENCE($,'23-39 45 11 17','Liquid Waste Separators',#8454,$,$); -#8459=IFCCLASSIFICATIONREFERENCE($,'23-39 45 11 19','Liquid Waste Pond and Reservoir Products',#8454,$,$); -#8460=IFCCLASSIFICATIONREFERENCE($,'23-39 45 11 19 11','Liquid Waste Pond Covers',#8459,$,$); -#8461=IFCCLASSIFICATIONREFERENCE($,'23-39 45 11 19 13','Liquid Waste Pond Liners',#8459,$,$); -#8462=IFCCLASSIFICATIONREFERENCE($,'23-39 45 11 21','Additives for Treatment of Liquid Waste',#8454,$,$); -#8463=IFCCLASSIFICATIONREFERENCE($,'23-39 45 11 21 11','Additives for Waste Water and Sewage Treatment',#8462,$,$); -#8464=IFCCLASSIFICATIONREFERENCE($,'23-39 45 11 21 13','Additives for Residue Treatment',#8462,$,$); -#8465=IFCCLASSIFICATIONREFERENCE($,'23-39 45 13','Liquid Waste Monitoring and Control',#8453,$,$); -#8466=IFCCLASSIFICATIONREFERENCE($,'23-39 45 13 11','Detectors of Water Pollution',#8465,$,$); -#8467=IFCCLASSIFICATIONREFERENCE($,'23-39 45 15','Solid Waste Disposal Plant Products',#8453,$,$); -#8468=IFCCLASSIFICATIONREFERENCE($,'23-39 45 15 11','Chutes and Collectors',#8467,$,$); -#8469=IFCCLASSIFICATIONREFERENCE($,'23-39 45 15 13','Pneumatic Waste Equipment',#8467,$,$); -#8470=IFCCLASSIFICATIONREFERENCE($,'23-39 45 15 15','Incineration Plant',#8467,$,$); -#8471=IFCCLASSIFICATIONREFERENCE($,'23-39 45 15 15 11','Packaged Incinerators',#8470,$,$); -#8472=IFCCLASSIFICATIONREFERENCE($,'23-39 45 15 17','Crusher Plant',#8467,$,$); -#8473=IFCCLASSIFICATIONREFERENCE($,'23-39 45 15 17 11','Waste Compactors and Destructors',#8472,$,$); -#8474=IFCCLASSIFICATIONREFERENCE($,'23-39 45 15 19','Baling Plant',#8467,$,$); -#8475=IFCCLASSIFICATIONREFERENCE($,'23-39 45 15 21','Pulping Machines',#8467,$,$); -#8476=IFCCLASSIFICATIONREFERENCE($,'23-39 45 17','Solid Waste Handling Products',#8453,$,$); -#8477=IFCCLASSIFICATIONREFERENCE($,'23-39 45 19','Solid Waste Impelling Equipment',#8453,$,$); -#8478=IFCCLASSIFICATIONREFERENCE($,'23-39 45 21','Solid Waste Treatment Equipment',#8453,$,$); -#8479=IFCCLASSIFICATIONREFERENCE($,'23-39 45 21 11','Solid Waste Compactors, Destructors, and Balers',#8478,$,$); -#8480=IFCCLASSIFICATIONREFERENCE($,'23-39 45 21 13','Solid Waste Crushers',#8478,$,$); -#8481=IFCCLASSIFICATIONREFERENCE($,'23-39 45 21 15','Solid Waste Pulping Machines',#8478,$,$); -#8482=IFCCLASSIFICATIONREFERENCE($,'23-39 45 21 17','Solid Waste Shredding Machines',#8478,$,$); -#8483=IFCCLASSIFICATIONREFERENCE($,'23-39 45 21 19','Incinerators',#8478,$,$); -#8484=IFCCLASSIFICATIONREFERENCE($,'23-39 45 21 19 11','Solid Waste Incinerators',#8483,$,$); -#8485=IFCCLASSIFICATIONREFERENCE($,'23-39 45 21 19 13','Packaged Incinerators',#8483,$,$); -#8486=IFCCLASSIFICATIONREFERENCE($,'23-39 45 23','Solid Waste Monitoring and Control Equipment',#8453,$,$); -#8487=IFCCLASSIFICATIONREFERENCE($,'23-39 45 23 11','Solid Waste Metal Detectors',#8486,$,$); -#8488=IFCCLASSIFICATIONREFERENCE($,'23-39 45 23 13','Solid Waste Detectors for Other Solids',#8486,$,$); -#8489=IFCCLASSIFICATIONREFERENCE($,'23-39 45 25','Solid Waste Collection and Removal Products',#8453,$,$); -#8490=IFCCLASSIFICATIONREFERENCE($,'23-39 45 25 11','Complete Solid Waste Removal Systems',#8489,$,$); -#8491=IFCCLASSIFICATIONREFERENCE($,'23-39 45 25 13','Solid Waste Bins',#8489,$,$); -#8492=IFCCLASSIFICATIONREFERENCE($,'23-39 45 25 15','Gravity Chute Solid Waste Systems',#8489,$,$); -#8493=IFCCLASSIFICATIONREFERENCE($,'23-39 45 25 17','Refuse Disposal Chutes',#8489,$,$); -#8494=IFCCLASSIFICATIONREFERENCE($,'23-39 45 25 17 11','Refuse Hoppers',#8493,$,$); -#8495=IFCCLASSIFICATIONREFERENCE($,'23-39 45 25 17 13','Refuse Chute Doors',#8493,$,$); -#8496=IFCCLASSIFICATIONREFERENCE($,'23-39 45 25 17 15','Refuse Chute Decontamination Units',#8493,$,$); -#8497=IFCCLASSIFICATIONREFERENCE($,'23-39 45 27','Solid Waste Handling Systems',#8453,$,$); -#8498=IFCCLASSIFICATIONREFERENCE($,'23-39 45 27 11','Refuse Compactors',#8497,$,$); -#8499=IFCCLASSIFICATIONREFERENCE($,'23-39 45 27 13','Refuse Containers',#8497,$,$); -#8500=IFCCLASSIFICATIONREFERENCE($,'23-39 45 27 15','Dust Collectors',#8497,$,$); -#8501=IFCCLASSIFICATIONREFERENCE($,'23-39 45 27 17','Utility Poles',#8497,$,$); -#8502=IFCCLASSIFICATIONREFERENCE($,'23-39 47 00','Offshore Structures',#8033,$,$); +#1=IFCPROJECTLIBRARY($,$,'OmniClass',$,$,$,$,$,$); +#2=IFCCLASSIFICATION('OmniClass','(OCCS)','2017-03-28','OmniClass','The OmniClass Construction Classification System (known as OmniClass\X2\2122\X0\ or OCCS) is a classification system for the construction industry. OmniClass is useful for many applications, from organizing library materials, product literature, and project information, to providing a classification structure for electronic databases.','http://www.omniclass.org/',('-',' ')); +#3=IFCRELASSOCIATESCLASSIFICATION('1qt9lErCr5hQsihRukSfaU',$,$,$,(#1),#2); +#4=IFCCLASSIFICATIONREFERENCE($,'Table 13 - Space by Function',$,#2,'Assigns a functional classification to ARCHICAD Zones based on this OmniClass (edition 2012) specification.\X2\000A000A\X0\For example: use this rule to comply with ''Concept Design BIM 2010'' MVD (GSA) and ''FM Handover'' (COBie) MVDs, which require such classification for IfcSpace entities.\X2\000A000A\X0\''Apply'' creates a Classification Reference for selected IfcSpace (or IfcSpaceType) entities, using OmniClass-required attributes derived from the item that you choose in the following list.\X2\000A00090009\X0\',$); +#5=IFCCLASSIFICATIONREFERENCE($,'13-11 00 00','Space Planning Types',#4,$,$); +#6=IFCCLASSIFICATIONREFERENCE($,'13-11 11 00','Planned Work Space',#5,$,$); +#7=IFCCLASSIFICATIONREFERENCE($,'13-11 13 00','Planned Building Service Space',#5,$,$); +#8=IFCCLASSIFICATIONREFERENCE($,'13-11 15 00','Planned Amenity/Support Space',#5,$,$); +#9=IFCCLASSIFICATIONREFERENCE($,'13-11 17 00','Planned Circulation Space',#5,$,$); +#10=IFCCLASSIFICATIONREFERENCE($,'13-11 19 00','Planned Parking Space',#5,$,$); +#11=IFCCLASSIFICATIONREFERENCE($,'13-13 00 00','Void Areas',#4,$,$); +#12=IFCCLASSIFICATIONREFERENCE($,'13-13 11 00','Light Well',#11,$,$); +#13=IFCCLASSIFICATIONREFERENCE($,'13-13 13 00','Air Shaft',#11,$,$); +#14=IFCCLASSIFICATIONREFERENCE($,'13-13 15 00','Occupant Void Area',#11,$,$); +#15=IFCCLASSIFICATIONREFERENCE($,'13-15 00 00','Wall Spaces',#4,$,$); +#16=IFCCLASSIFICATIONREFERENCE($,'13-15 11 00','Exterior Wall Space',#15,$,$); +#17=IFCCLASSIFICATIONREFERENCE($,'13-15 13 00','Interior Wall Space',#15,$,$); +#18=IFCCLASSIFICATIONREFERENCE($,'13-17 00 00','Encroachment Spaces',#4,$,$); +#19=IFCCLASSIFICATIONREFERENCE($,'13-17 11 00','Interior Encroachment',#18,$,$); +#20=IFCCLASSIFICATIONREFERENCE($,'13-17 13 00','Perimeter Encroachment',#18,$,$); +#21=IFCCLASSIFICATIONREFERENCE($,'13-21 00 00','Parking Spaces',#4,$,$); +#22=IFCCLASSIFICATIONREFERENCE($,'13-21 11 00','Exterior Parking Spaces',#21,$,$); +#23=IFCCLASSIFICATIONREFERENCE($,'13-21 11 11','Exterior Parking Circulation',#22,$,$); +#24=IFCCLASSIFICATIONREFERENCE($,'13-21 11 13','Exterior Parking Access Control Point',#22,$,$); +#25=IFCCLASSIFICATIONREFERENCE($,'13-21 11 15','Exterior Parking Stall',#22,$,$); +#26=IFCCLASSIFICATIONREFERENCE($,'13-21 13 00','Interior Parking Spaces',#21,$,$); +#27=IFCCLASSIFICATIONREFERENCE($,'13-21 13 11','Interior Parking Ramp and Circulation',#26,$,$); +#28=IFCCLASSIFICATIONREFERENCE($,'13-21 13 13','Interior Parking Access Control Point',#26,$,$); +#29=IFCCLASSIFICATIONREFERENCE($,'13-21 13 15','Interior Parking Stall',#26,$,$); +#30=IFCCLASSIFICATIONREFERENCE($,'13-21 13 17','Interior Vehicle Service Space',#26,$,$); +#31=IFCCLASSIFICATIONREFERENCE($,'13-23 00 00','Facility Service Spaces',#4,$,$); +#32=IFCCLASSIFICATIONREFERENCE($,'13-23 11 00','Vertical Penetration',#31,$,$); +#33=IFCCLASSIFICATIONREFERENCE($,'13-23 11 11','Mechanical Circulation',#32,$,$); +#34=IFCCLASSIFICATIONREFERENCE($,'13-23 11 11 11','Elevator Shaft',#33,$,$); +#35=IFCCLASSIFICATIONREFERENCE($,'13-23 11 11 13','Elevator Pit',#33,$,$); +#36=IFCCLASSIFICATIONREFERENCE($,'13-23 11 11 15','Elevator Cab',#33,$,$); +#37=IFCCLASSIFICATIONREFERENCE($,'13-23 11 11 17','Elevator Machine Room',#33,$,$); +#38=IFCCLASSIFICATIONREFERENCE($,'13-23 11 11 19','Dumbwaiter',#33,$,$); +#39=IFCCLASSIFICATIONREFERENCE($,'13-23 11 11 21','Escalator',#33,$,$); +#40=IFCCLASSIFICATIONREFERENCE($,'13-23 11 11 23','Freight Elevator',#33,$,$); +#41=IFCCLASSIFICATIONREFERENCE($,'13-23 11 13','Stairway',#32,$,$); +#42=IFCCLASSIFICATIONREFERENCE($,'13-23 11 13 11','Egress Stairway',#41,$,$); +#43=IFCCLASSIFICATIONREFERENCE($,'13-23 11 13 13','Tenant Stairway',#41,$,$); +#44=IFCCLASSIFICATIONREFERENCE($,'13-23 11 15','Monumental Stair',#32,$,$); +#45=IFCCLASSIFICATIONREFERENCE($,'13-23 11 17','Ramp',#32,$,$); +#46=IFCCLASSIFICATIONREFERENCE($,'13-23 11 19','Chimney',#32,$,$); +#47=IFCCLASSIFICATIONREFERENCE($,'13-23 11 21','Chute',#32,$,$); +#48=IFCCLASSIFICATIONREFERENCE($,'13-23 11 23','Service Riser Space',#32,$,$); +#49=IFCCLASSIFICATIONREFERENCE($,'13-23 11 23 11','Power Distribution Riser',#48,$,$); +#50=IFCCLASSIFICATIONREFERENCE($,'13-23 11 23 13','Information Signal Distribution Riser',#48,$,$); +#51=IFCCLASSIFICATIONREFERENCE($,'13-23 11 23 15','Gas Distribution Riser',#48,$,$); +#52=IFCCLASSIFICATIONREFERENCE($,'13-23 11 23 17','Liquid Distribution Riser',#48,$,$); +#53=IFCCLASSIFICATIONREFERENCE($,'13-23 12 00','Horizontal Infrastructure/Service Space, Non-Occupied',#31,$,$); +#54=IFCCLASSIFICATIONREFERENCE($,'13-23 12 11','Power Distribution Network',#53,$,$); +#55=IFCCLASSIFICATIONREFERENCE($,'13-23 12 13','Information Signal Network',#53,$,$); +#56=IFCCLASSIFICATIONREFERENCE($,'13-23 12 15','Gas Distribution Network',#53,$,$); +#57=IFCCLASSIFICATIONREFERENCE($,'13-23 12 17','Liquid Distribution Spaces',#53,$,$); +#58=IFCCLASSIFICATIONREFERENCE($,'13-23 13 00','Control Room',#31,$,$); +#59=IFCCLASSIFICATIONREFERENCE($,'13-23 13 11','Fire Command Center',#58,$,$); +#60=IFCCLASSIFICATIONREFERENCE($,'13-23 13 13','Guard Stations',#58,$,$); +#61=IFCCLASSIFICATIONREFERENCE($,'13-23 15 00','Loading Dock',#31,$,$); +#62=IFCCLASSIFICATIONREFERENCE($,'13-23 17 00','Restroom',#31,$,$); +#63=IFCCLASSIFICATIONREFERENCE($,'13-23 17 11','Men''s Restroom',#62,$,$); +#64=IFCCLASSIFICATIONREFERENCE($,'13-23 17 13','Women''s Restroom',#62,$,$); +#65=IFCCLASSIFICATIONREFERENCE($,'13-23 17 15','Unisex Restroom',#62,$,$); +#66=IFCCLASSIFICATIONREFERENCE($,'13-23 19 00','Utility Equipment Room',#31,$,$); +#67=IFCCLASSIFICATIONREFERENCE($,'13-23 19 11','Refrigerant Machinery Room',#66,$,$); +#68=IFCCLASSIFICATIONREFERENCE($,'13-23 19 13','Furnace Room',#66,$,$); +#69=IFCCLASSIFICATIONREFERENCE($,'13-23 19 15','Incinerator Room',#66,$,$); +#70=IFCCLASSIFICATIONREFERENCE($,'13-23 19 17','Fuel Room',#66,$,$); +#71=IFCCLASSIFICATIONREFERENCE($,'13-23 19 19','Gas Room',#66,$,$); +#72=IFCCLASSIFICATIONREFERENCE($,'13-23 19 21','Liquid Storage Room',#66,$,$); +#73=IFCCLASSIFICATIONREFERENCE($,'13-23 19 23','Liquid Use, Dispensing and Mixing Room',#66,$,$); +#74=IFCCLASSIFICATIONREFERENCE($,'13-23 19 25','Hydrogen Cutoff Room',#66,$,$); +#75=IFCCLASSIFICATIONREFERENCE($,'13-23 19 27','Electrical Room',#66,$,$); +#76=IFCCLASSIFICATIONREFERENCE($,'13-23 19 29','Switch Room',#66,$,$); +#77=IFCCLASSIFICATIONREFERENCE($,'13-23 19 31','Telecommunications Room',#66,$,$); +#78=IFCCLASSIFICATIONREFERENCE($,'13-23 19 33','Transformer Vault',#66,$,$); +#79=IFCCLASSIFICATIONREFERENCE($,'13-23 21 00','Waste and Recycling Spaces',#31,$,$); +#80=IFCCLASSIFICATIONREFERENCE($,'13-23 21 11','Hazardous Waste Storage',#79,$,$); +#81=IFCCLASSIFICATIONREFERENCE($,'13-23 23 00','Building Service Support Spaces',#31,$,$); +#82=IFCCLASSIFICATIONREFERENCE($,'13-23 23 11','Building Manager Office',#81,$,$); +#83=IFCCLASSIFICATIONREFERENCE($,'13-23 23 13','Custodial Space',#81,$,$); +#84=IFCCLASSIFICATIONREFERENCE($,'13-23 23 15','Shop Area',#81,$,$); +#85=IFCCLASSIFICATIONREFERENCE($,'13-23 23 17','Access Chamber',#81,$,$); +#86=IFCCLASSIFICATIONREFERENCE($,'13-23 23 19','Areaway',#81,$,$); +#87=IFCCLASSIFICATIONREFERENCE($,'13-23 23 21','Service Space',#81,$,$); +#88=IFCCLASSIFICATIONREFERENCE($,'13-23 23 23','Furred Space',#81,$,$); +#89=IFCCLASSIFICATIONREFERENCE($,'13-23 23 25','Crawl Space',#81,$,$); +#90=IFCCLASSIFICATIONREFERENCE($,'13-23 23 27','Attic Space',#81,$,$); +#91=IFCCLASSIFICATIONREFERENCE($,'13-23 23 29','Plenum',#81,$,$); +#92=IFCCLASSIFICATIONREFERENCE($,'13-23 25 00','Equipment Platform',#31,$,$); +#93=IFCCLASSIFICATIONREFERENCE($,'13-23 27 00','Interstitial Space',#31,$,$); +#94=IFCCLASSIFICATIONREFERENCE($,'13-23 29 00','Unimproved Shell',#31,$,$); +#95=IFCCLASSIFICATIONREFERENCE($,'13-23 31 00','Alteration or Conversion Space',#31,$,$); +#96=IFCCLASSIFICATIONREFERENCE($,'13-25 00 00','Circulation Spaces',#4,$,$); +#97=IFCCLASSIFICATIONREFERENCE($,'13-25 11 00','Primary Circulation Spaces',#96,$,$); +#98=IFCCLASSIFICATIONREFERENCE($,'13-25 11 11','Corridor',#97,$,$); +#99=IFCCLASSIFICATIONREFERENCE($,'13-25 11 13','Aisle',#97,$,$); +#100=IFCCLASSIFICATIONREFERENCE($,'13-25 11 15','Mall',#97,$,$); +#101=IFCCLASSIFICATIONREFERENCE($,'13-25 11 17','Concourse',#97,$,$); +#102=IFCCLASSIFICATIONREFERENCE($,'13-25 11 19','Breezeway',#97,$,$); +#103=IFCCLASSIFICATIONREFERENCE($,'13-25 11 21','Moving Walkway',#97,$,$); +#104=IFCCLASSIFICATIONREFERENCE($,'13-25 13 00','Transitional Circulation Spaces',#96,$,$); +#105=IFCCLASSIFICATIONREFERENCE($,'13-25 13 11','Entry Vestibule',#104,$,$); +#106=IFCCLASSIFICATIONREFERENCE($,'13-25 13 13','Entry Lobby',#104,$,$); +#107=IFCCLASSIFICATIONREFERENCE($,'13-25 13 15','Box Lobby',#104,$,$); +#108=IFCCLASSIFICATIONREFERENCE($,'13-25 13 17','Vestibule',#104,$,$); +#109=IFCCLASSIFICATIONREFERENCE($,'13-25 13 19','Elevator Lobby',#104,$,$); +#110=IFCCLASSIFICATIONREFERENCE($,'13-25 13 21','Freight Elevator Vestibule',#104,$,$); +#111=IFCCLASSIFICATIONREFERENCE($,'13-25 13 23','Landing',#104,$,$); +#112=IFCCLASSIFICATIONREFERENCE($,'13-25 13 25','Anteroom',#104,$,$); +#113=IFCCLASSIFICATIONREFERENCE($,'13-25 13 27','Air Lock',#104,$,$); +#114=IFCCLASSIFICATIONREFERENCE($,'13-25 13 29','Sally Port',#104,$,$); +#115=IFCCLASSIFICATIONREFERENCE($,'13-25 13 31','Jet Way',#104,$,$); +#116=IFCCLASSIFICATIONREFERENCE($,'13-25 15 00','Connector',#96,$,$); +#117=IFCCLASSIFICATIONREFERENCE($,'13-25 17 00','External Circulation Spaces',#96,$,$); +#118=IFCCLASSIFICATIONREFERENCE($,'13-25 19 00','Secondary Circulation Spaces',#96,$,$); +#119=IFCCLASSIFICATIONREFERENCE($,'13-25 19 11','Door Set-Back',#118,$,$); +#120=IFCCLASSIFICATIONREFERENCE($,'13-25 21 00','Restricted Spaces',#96,$,$); +#121=IFCCLASSIFICATIONREFERENCE($,'13-25 23 00','Refuge Spaces',#96,$,$); +#122=IFCCLASSIFICATIONREFERENCE($,'13-31 00 00','Education and Training Spaces',#4,$,$); +#123=IFCCLASSIFICATIONREFERENCE($,'13-31 11 00','Breakout Space',#122,$,$); +#124=IFCCLASSIFICATIONREFERENCE($,'13-31 13 00','Lecture and Classroom Spaces',#122,$,$); +#125=IFCCLASSIFICATIONREFERENCE($,'13-31 13 11','Lecture Classroom',#124,$,$); +#126=IFCCLASSIFICATIONREFERENCE($,'13-31 13 13','Classrooms (age 9 plus)',#124,$,$); +#127=IFCCLASSIFICATIONREFERENCE($,'13-31 13 15','Classrooms (ages 5\X2\2013\X0\8)',#124,$,$); +#128=IFCCLASSIFICATIONREFERENCE($,'13-31 13 17','Lecture Hall (Fixed Seats)',#124,$,$); +#129=IFCCLASSIFICATIONREFERENCE($,'13-31 13 19','Assembly Hall',#124,$,$); +#130=IFCCLASSIFICATIONREFERENCE($,'13-31 13 21','Seminar Room',#124,$,$); +#131=IFCCLASSIFICATIONREFERENCE($,'13-31 15 00','Class Laboratories',#122,$,$); +#132=IFCCLASSIFICATIONREFERENCE($,'13-31 15 11','Open Class Laboratory',#131,$,$); +#133=IFCCLASSIFICATIONREFERENCE($,'13-31 15 11 11','Physics Teaching Laboratory',#132,$,$); +#134=IFCCLASSIFICATIONREFERENCE($,'13-31 15 11 13','Astronomy Teaching Laboratory',#132,$,$); +#135=IFCCLASSIFICATIONREFERENCE($,'13-31 15 13','Research/non-class Class Laboratory',#131,$,$); +#136=IFCCLASSIFICATIONREFERENCE($,'13-31 15 15','Laboratory Service Space',#131,$,$); +#137=IFCCLASSIFICATIONREFERENCE($,'13-31 17 00','Training Spaces',#122,$,$); +#138=IFCCLASSIFICATIONREFERENCE($,'13-31 17 11','Computer Lab',#137,$,$); +#139=IFCCLASSIFICATIONREFERENCE($,'13-31 17 13','Woodshop/Metalshop',#137,$,$); +#140=IFCCLASSIFICATIONREFERENCE($,'13-31 17 15','Training Support Space',#137,$,$); +#141=IFCCLASSIFICATIONREFERENCE($,'13-31 17 17','Religious Education Space',#137,$,$); +#142=IFCCLASSIFICATIONREFERENCE($,'13-31 19 00','Study Spaces',#122,$,$); +#143=IFCCLASSIFICATIONREFERENCE($,'13-31 19 13','Study Room',#142,$,$); +#144=IFCCLASSIFICATIONREFERENCE($,'13-31 19 15','Study Service',#142,$,$); +#145=IFCCLASSIFICATIONREFERENCE($,'13-33 00 00','Recreation Spaces',#4,$,$); +#146=IFCCLASSIFICATIONREFERENCE($,'13-33 11 00','Athletic Recreation Spaces',#145,$,$); +#147=IFCCLASSIFICATIONREFERENCE($,'13-33 11 11','Athletic Spectator Seating',#146,$,$); +#148=IFCCLASSIFICATIONREFERENCE($,'13-33 11 11 11','Bleacher',#147,$,$); +#149=IFCCLASSIFICATIONREFERENCE($,'13-33 11 13','Team Athletic Recreation Spaces',#146,$,$); +#150=IFCCLASSIFICATIONREFERENCE($,'13-33 11 13 11','Baseball Field',#149,$,$); +#151=IFCCLASSIFICATIONREFERENCE($,'13-33 11 13 13','Softball Fields',#149,$,$); +#152=IFCCLASSIFICATIONREFERENCE($,'13-33 11 13 15','Dugouts',#149,$,$); +#153=IFCCLASSIFICATIONREFERENCE($,'13-33 11 13 17','Grass Playing Fields',#149,$,$); +#154=IFCCLASSIFICATIONREFERENCE($,'13-33 11 13 19','Synthetic Fields',#149,$,$); +#155=IFCCLASSIFICATIONREFERENCE($,'13-33 11 13 21','Football Field',#149,$,$); +#156=IFCCLASSIFICATIONREFERENCE($,'13-33 11 13 23','Soccer Field',#149,$,$); +#157=IFCCLASSIFICATIONREFERENCE($,'13-33 11 13 25','Basketball Courts',#149,$,$); +#158=IFCCLASSIFICATIONREFERENCE($,'13-33 11 13 27','Field Light Poles',#149,$,$); +#159=IFCCLASSIFICATIONREFERENCE($,'13-33 11 13 29','Press Box',#149,$,$); +#160=IFCCLASSIFICATIONREFERENCE($,'13-33 11 13 31','Scoreboards',#149,$,$); +#161=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15','Individual Athletic Recreation Spaces',#146,$,$); +#162=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 11','Hard Playing Surfaces',#161,$,$); +#163=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 13','Tennis Courts',#161,$,$); +#164=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 15','Volleyball Court',#161,$,$); +#165=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 17','Golf Course',#161,$,$); +#166=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 19','Driving Range',#161,$,$); +#167=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 21','Golf Course Support Space',#161,$,$); +#168=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 23','Skating Rink',#161,$,$); +#169=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 25','Boxing Ring',#161,$,$); +#170=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 27','Wrestling Mat',#161,$,$); +#171=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 29','Diving Board',#161,$,$); +#172=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 31','Bowling Lane',#161,$,$); +#173=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 33','Dart Throwing Area',#161,$,$); +#174=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 35','Circuit Training Course Area',#161,$,$); +#175=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 37','Running Tracks',#161,$,$); +#176=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 39','Ski Lift Space',#161,$,$); +#177=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 41','Exercise Space',#161,$,$); +#178=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 43','Workout Station',#161,$,$); +#179=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 45','Aerobic Studio',#161,$,$); +#180=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 47','Climbing Wall',#161,$,$); +#181=IFCCLASSIFICATIONREFERENCE($,'13-33 11 15 49','Ropes Course Elements',#161,$,$); +#182=IFCCLASSIFICATIONREFERENCE($,'13-33 13 00','Swimming Pools',#145,$,$); +#183=IFCCLASSIFICATIONREFERENCE($,'13-33 13 11','Outdoor Swimming Pool',#182,$,$); +#184=IFCCLASSIFICATIONREFERENCE($,'13-33 13 13','Indoor Swimming Pool',#182,$,$); +#185=IFCCLASSIFICATIONREFERENCE($,'13-33 13 13 11','Diving Tank',#184,$,$); +#186=IFCCLASSIFICATIONREFERENCE($,'13-33 15 00','Non-Athletic Recreation Spaces',#145,$,$); +#187=IFCCLASSIFICATIONREFERENCE($,'13-33 15 11','Park',#186,$,$); +#188=IFCCLASSIFICATIONREFERENCE($,'13-33 15 13','Pleasure Garden',#186,$,$); +#189=IFCCLASSIFICATIONREFERENCE($,'13-33 15 15','Indoor Firing Range',#186,$,$); +#190=IFCCLASSIFICATIONREFERENCE($,'13-33 15 17','Outdoor Shooting Range',#186,$,$); +#191=IFCCLASSIFICATIONREFERENCE($,'13-33 15 19','Recreational Deck',#186,$,$); +#192=IFCCLASSIFICATIONREFERENCE($,'13-33 15 21','Playground',#186,$,$); +#193=IFCCLASSIFICATIONREFERENCE($,'13-33 15 23','Game Room',#186,$,$); +#194=IFCCLASSIFICATIONREFERENCE($,'13-33 15 25','Gambling Table',#186,$,$); +#195=IFCCLASSIFICATIONREFERENCE($,'13-33 15 27','Amusement Ride',#186,$,$); +#196=IFCCLASSIFICATIONREFERENCE($,'13-33 15 29','Parade Grounds',#186,$,$); +#197=IFCCLASSIFICATIONREFERENCE($,'13-33 15 31','Computer-Aided Visual Environment',#186,$,$); +#198=IFCCLASSIFICATIONREFERENCE($,'13-33 15 33','Hobby and Craft Center',#186,$,$); +#199=IFCCLASSIFICATIONREFERENCE($,'13-33 15 35','Dance Floors',#186,$,$); +#200=IFCCLASSIFICATIONREFERENCE($,'13-33 17 00','Wellness Spaces',#145,$,$); +#201=IFCCLASSIFICATIONREFERENCE($,'13-33 17 11','Fitness Center',#200,$,$); +#202=IFCCLASSIFICATIONREFERENCE($,'13-33 17 11 11','Exercise Room',#201,$,$); +#203=IFCCLASSIFICATIONREFERENCE($,'13-33 17 11 13','Weight Room',#201,$,$); +#204=IFCCLASSIFICATIONREFERENCE($,'13-35 00 00','Government Spaces',#4,$,$); +#205=IFCCLASSIFICATIONREFERENCE($,'13-35 11 00','Judicial Spaces',#204,$,$); +#206=IFCCLASSIFICATIONREFERENCE($,'13-35 11 11','Courtroom',#205,$,$); +#207=IFCCLASSIFICATIONREFERENCE($,'13-35 11 11 11','Jury Box',#206,$,$); +#208=IFCCLASSIFICATIONREFERENCE($,'13-35 11 11 13','Jury Room',#206,$,$); +#209=IFCCLASSIFICATIONREFERENCE($,'13-35 11 11 15','Judge\X2\2019\X0\s Bench',#206,$,$); +#210=IFCCLASSIFICATIONREFERENCE($,'13-35 11 11 17','Evidence Room',#206,$,$); +#211=IFCCLASSIFICATIONREFERENCE($,'13-35 11 11 19','Jury Assembly Space',#206,$,$); +#212=IFCCLASSIFICATIONREFERENCE($,'13-35 11 11 21','Witness Stand',#206,$,$); +#213=IFCCLASSIFICATIONREFERENCE($,'13-35 11 13','Judge\X2\2019\X0\s Chambers',#205,$,$); +#214=IFCCLASSIFICATIONREFERENCE($,'13-35 11 13 11','JCC\X2\2013\X0\Judicial Chambers',#213,$,$); +#215=IFCCLASSIFICATIONREFERENCE($,'13-35 11 13 13','Law Clerk Space',#213,$,$); +#216=IFCCLASSIFICATIONREFERENCE($,'13-35 11 15','Robing Area/Room',#205,$,$); +#217=IFCCLASSIFICATIONREFERENCE($,'13-35 11 19','Hearing Room',#205,$,$); +#218=IFCCLASSIFICATIONREFERENCE($,'13-35 11 19 11','JHR\X2\2013\X0\Judicial Hearing Room',#217,$,$); +#219=IFCCLASSIFICATIONREFERENCE($,'13-35 13 00','Legislative Spaces',#204,$,$); +#220=IFCCLASSIFICATIONREFERENCE($,'13-35 13 11','Council Chambers',#219,$,$); +#221=IFCCLASSIFICATIONREFERENCE($,'13-35 13 13','Legislative Hearing Room',#219,$,$); +#222=IFCCLASSIFICATIONREFERENCE($,'13-35 15 00','Military Spaces',#204,$,$); +#223=IFCCLASSIFICATIONREFERENCE($,'13-35 15 11','Armory',#222,$,$); +#224=IFCCLASSIFICATIONREFERENCE($,'13-35 15 13','Armory Service Space',#222,$,$); +#225=IFCCLASSIFICATIONREFERENCE($,'13-37 00 00','Artistic Spaces',#4,$,$); +#226=IFCCLASSIFICATIONREFERENCE($,'13-37 11 00','Performance Spaces',#225,$,$); +#227=IFCCLASSIFICATIONREFERENCE($,'13-37 11 11','Outdoor Theater',#226,$,$); +#228=IFCCLASSIFICATIONREFERENCE($,'13-37 11 13','General Performance Spaces',#226,$,$); +#229=IFCCLASSIFICATIONREFERENCE($,'13-37 11 13 11','Acting Stage',#228,$,$); +#230=IFCCLASSIFICATIONREFERENCE($,'13-37 11 13 13','Orchestra Pit',#228,$,$); +#231=IFCCLASSIFICATIONREFERENCE($,'13-37 11 13 15','Performance Rehearsal Space',#228,$,$); +#232=IFCCLASSIFICATIONREFERENCE($,'13-37 11 13 17','Soundstage',#228,$,$); +#233=IFCCLASSIFICATIONREFERENCE($,'13-37 11 13 19','Performance Hall',#228,$,$); +#234=IFCCLASSIFICATIONREFERENCE($,'13-37 11 13 21','Band Training Space',#228,$,$); +#235=IFCCLASSIFICATIONREFERENCE($,'13-37 11 15','Audience Spaces',#226,$,$); +#236=IFCCLASSIFICATIONREFERENCE($,'13-37 11 15 11','Pre-Function Lobby',#235,$,$); +#237=IFCCLASSIFICATIONREFERENCE($,'13-37 11 15 13','Audience Seating Space',#235,$,$); +#238=IFCCLASSIFICATIONREFERENCE($,'13-37 11 17','Supporting Performance Spaces',#226,$,$); +#239=IFCCLASSIFICATIONREFERENCE($,'13-37 11 17 11','Projection Booth',#238,$,$); +#240=IFCCLASSIFICATIONREFERENCE($,'13-37 11 17 13','Catwalk',#238,$,$); +#241=IFCCLASSIFICATIONREFERENCE($,'13-37 11 17 15','Stage Wings',#238,$,$); +#242=IFCCLASSIFICATIONREFERENCE($,'13-37 11 17 17','Motion Picture Screen Space',#238,$,$); +#243=IFCCLASSIFICATIONREFERENCE($,'13-37 13 00','Display Spaces',#225,$,$); +#244=IFCCLASSIFICATIONREFERENCE($,'13-37 13 11','Art Gallery',#243,$,$); +#245=IFCCLASSIFICATIONREFERENCE($,'13-37 13 13','Exhibit Gallery',#243,$,$); +#246=IFCCLASSIFICATIONREFERENCE($,'13-37 13 15','Sculpture Garden',#243,$,$); +#247=IFCCLASSIFICATIONREFERENCE($,'13-37 13 17','Ornamental Garden',#243,$,$); +#248=IFCCLASSIFICATIONREFERENCE($,'13-37 13 19','Observation Deck',#243,$,$); +#249=IFCCLASSIFICATIONREFERENCE($,'13-37 15 00','Creative Spaces',#225,$,$); +#250=IFCCLASSIFICATIONREFERENCE($,'13-37 15 11','Recording Studio',#249,$,$); +#251=IFCCLASSIFICATIONREFERENCE($,'13-37 15 13','Artist\X2\2019\X0\s Studio',#249,$,$); +#252=IFCCLASSIFICATIONREFERENCE($,'13-37 15 15','Photo Lab',#249,$,$); +#253=IFCCLASSIFICATIONREFERENCE($,'13-37 15 15 11','Motion Picture Exchange',#252,$,$); +#254=IFCCLASSIFICATIONREFERENCE($,'13-37 15 17','Media Production',#249,$,$); +#255=IFCCLASSIFICATIONREFERENCE($,'13-37 15 17 11','Media Production Support',#254,$,$); +#256=IFCCLASSIFICATIONREFERENCE($,'13-37 15 17 13','Sound Lock',#254,$,$); +#257=IFCCLASSIFICATIONREFERENCE($,'13-37 15 19','Zen Garden',#249,$,$); +#258=IFCCLASSIFICATIONREFERENCE($,'13-41 00 00','Museum Spaces',#4,$,$); +#259=IFCCLASSIFICATIONREFERENCE($,'13-41 11 00','Museum Gallery',#258,$,$); +#260=IFCCLASSIFICATIONREFERENCE($,'13-45 00 00','Library Spaces',#4,$,$); +#261=IFCCLASSIFICATIONREFERENCE($,'13-45 11 00','Library',#260,$,$); +#262=IFCCLASSIFICATIONREFERENCE($,'13-45 11 11','Library Stack',#261,$,$); +#263=IFCCLASSIFICATIONREFERENCE($,'13-47 00 00','Spiritual Spaces',#4,$,$); +#264=IFCCLASSIFICATIONREFERENCE($,'13-47 11 00','Worship spaces',#263,$,$); +#265=IFCCLASSIFICATIONREFERENCE($,'13-47 11 11','Meditation Chapel',#264,$,$); +#266=IFCCLASSIFICATIONREFERENCE($,'13-47 11 13','Altar',#264,$,$); +#267=IFCCLASSIFICATIONREFERENCE($,'13-47 11 15','Reflection Space',#264,$,$); +#268=IFCCLASSIFICATIONREFERENCE($,'13-47 11 17','Blessing Space',#264,$,$); +#269=IFCCLASSIFICATIONREFERENCE($,'13-47 11 19','Chapel',#264,$,$); +#270=IFCCLASSIFICATIONREFERENCE($,'13-47 11 21','Mihrab',#264,$,$); +#271=IFCCLASSIFICATIONREFERENCE($,'13-47 11 23','Shrine',#264,$,$); +#272=IFCCLASSIFICATIONREFERENCE($,'13-47 11 25','Sanctuary',#264,$,$); +#273=IFCCLASSIFICATIONREFERENCE($,'13-47 11 27','Confessional Space',#264,$,$); +#274=IFCCLASSIFICATIONREFERENCE($,'13-47 11 29','Ark',#264,$,$); +#275=IFCCLASSIFICATIONREFERENCE($,'13-47 11 31','Bimah',#264,$,$); +#276=IFCCLASSIFICATIONREFERENCE($,'13-47 11 33','Tabernacle',#264,$,$); +#277=IFCCLASSIFICATIONREFERENCE($,'13-47 11 35','Pulpit',#264,$,$); +#278=IFCCLASSIFICATIONREFERENCE($,'13-47 11 37','Choir Loft',#264,$,$); +#279=IFCCLASSIFICATIONREFERENCE($,'13-47 13 00','Ceremonial Spaces',#263,$,$); +#280=IFCCLASSIFICATIONREFERENCE($,'13-47 13 11','Marriage Sanctuary',#279,$,$); +#281=IFCCLASSIFICATIONREFERENCE($,'13-47 13 13','Baptistery',#279,$,$); +#282=IFCCLASSIFICATIONREFERENCE($,'13-47 13 15','Circumcision Space',#279,$,$); +#283=IFCCLASSIFICATIONREFERENCE($,'13-47 13 17','Cathedra',#279,$,$); +#284=IFCCLASSIFICATIONREFERENCE($,'13-47 15 00','Procession Spaces',#263,$,$); +#285=IFCCLASSIFICATIONREFERENCE($,'13-47 17 00','Death Spaces',#263,$,$); +#286=IFCCLASSIFICATIONREFERENCE($,'13-47 17 11','Crypt',#285,$,$); +#287=IFCCLASSIFICATIONREFERENCE($,'13-47 17 13','Morgue',#285,$,$); +#288=IFCCLASSIFICATIONREFERENCE($,'13-47 17 13 11','Morgue Compartment',#287,$,$); +#289=IFCCLASSIFICATIONREFERENCE($,'13-47 17 17','Grave Space',#285,$,$); +#290=IFCCLASSIFICATIONREFERENCE($,'13-49 00 00','Environmentally Controlled Spaces',#4,$,$); +#291=IFCCLASSIFICATIONREFERENCE($,'13-49 11 00','Anechoic Chamber',#290,$,$); +#292=IFCCLASSIFICATIONREFERENCE($,'13-49 13 00','Hazard Containment',#290,$,$); +#293=IFCCLASSIFICATIONREFERENCE($,'13-49 15 00','Clean Room',#290,$,$); +#294=IFCCLASSIFICATIONREFERENCE($,'13-49 15 11','Clean Room Class 1',#293,$,$); +#295=IFCCLASSIFICATIONREFERENCE($,'13-49 15 13','Clean Room Class 2',#293,$,$); +#296=IFCCLASSIFICATIONREFERENCE($,'13-49 15 15','Clean Room Class 3',#293,$,$); +#297=IFCCLASSIFICATIONREFERENCE($,'13-49 15 17','Clean Room Class 4',#293,$,$); +#298=IFCCLASSIFICATIONREFERENCE($,'13-49 15 19','Clean Room Class 5',#293,$,$); +#299=IFCCLASSIFICATIONREFERENCE($,'13-49 15 21','Clean Room Class 6',#293,$,$); +#300=IFCCLASSIFICATIONREFERENCE($,'13-49 15 23','Clean Room Class 7',#293,$,$); +#301=IFCCLASSIFICATIONREFERENCE($,'13-49 15 25','Clean Room Class 8',#293,$,$); +#302=IFCCLASSIFICATIONREFERENCE($,'13-49 15 27','Clean Room Class 9',#293,$,$); +#303=IFCCLASSIFICATIONREFERENCE($,'13-49 15 29','Clean Room Support Space',#293,$,$); +#304=IFCCLASSIFICATIONREFERENCE($,'13-49 17 00','Temperature and Pressure Chamber',#290,$,$); +#305=IFCCLASSIFICATIONREFERENCE($,'13-49 19 00','Data Center',#290,$,$); +#306=IFCCLASSIFICATIONREFERENCE($,'13-49 19 11','Data Center Tier I',#305,$,$); +#307=IFCCLASSIFICATIONREFERENCE($,'13-49 19 13','Data Center Tier II',#305,$,$); +#308=IFCCLASSIFICATIONREFERENCE($,'13-49 19 15','Data Center Tier III',#305,$,$); +#309=IFCCLASSIFICATIONREFERENCE($,'13-49 19 17','Data Center Tier IV',#305,$,$); +#310=IFCCLASSIFICATIONREFERENCE($,'13-49 19 19','Data Center Support Space',#305,$,$); +#311=IFCCLASSIFICATIONREFERENCE($,'13-49 21 00','Controlled Space Support',#290,$,$); +#312=IFCCLASSIFICATIONREFERENCE($,'13-49 23 00','Miscellaneous Environmentally Controlled Spaces',#290,$,$); +#313=IFCCLASSIFICATIONREFERENCE($,'13-49 23 11','Film Storage Vault',#312,$,$); +#314=IFCCLASSIFICATIONREFERENCE($,'13-49 23 13','Computer Server Room',#312,$,$); +#315=IFCCLASSIFICATIONREFERENCE($,'13-51 00 00','Healthcare Spaces',#4,$,$); +#316=IFCCLASSIFICATIONREFERENCE($,'13-51 11 00','General Examination Spaces',#315,$,$); +#317=IFCCLASSIFICATIONREFERENCE($,'13-51 11 11','Exam Room',#316,$,$); +#318=IFCCLASSIFICATIONREFERENCE($,'13-51 11 13','Exam Room, Airborne Infection Isolation',#316,$,$); +#319=IFCCLASSIFICATIONREFERENCE($,'13-51 11 15','Exam Room, Isolation',#316,$,$); +#320=IFCCLASSIFICATIONREFERENCE($,'13-51 11 17','Exam Room, OB/Gyn',#316,$,$); +#321=IFCCLASSIFICATIONREFERENCE($,'13-51 11 19','Exam Room, Pediatric',#316,$,$); +#322=IFCCLASSIFICATIONREFERENCE($,'13-51 11 21','Exam Room, Protective Environment Isolation',#316,$,$); +#323=IFCCLASSIFICATIONREFERENCE($,'13-51 11 23','Exam Room, Podiatry',#316,$,$); +#324=IFCCLASSIFICATIONREFERENCE($,'13-51 11 25','Exam Room, Security',#316,$,$); +#325=IFCCLASSIFICATIONREFERENCE($,'13-51 11 27','Height/Weight Screening Space',#316,$,$); +#326=IFCCLASSIFICATIONREFERENCE($,'13-51 11 29','Holding Room, Secured',#316,$,$); +#327=IFCCLASSIFICATIONREFERENCE($,'13-51 14 00','Inpatient Care Spaces',#315,$,$); +#328=IFCCLASSIFICATIONREFERENCE($,'13-51 14 11','Anteroom, Inpatient Airborne Infection Isolation',#327,$,$); +#329=IFCCLASSIFICATIONREFERENCE($,'13-51 14 13','Anteroom, Inpatient Protective Environment Isolation',#327,$,$); +#330=IFCCLASSIFICATIONREFERENCE($,'13-51 14 17','Anteroom, Inpatient Isolation/Seclusion',#327,$,$); +#331=IFCCLASSIFICATIONREFERENCE($,'13-51 14 19','Labor, Delivery, Recovery, Postpartum Room',#327,$,$); +#332=IFCCLASSIFICATIONREFERENCE($,'13-51 14 21','Medical Information Computer System Room',#327,$,$); +#333=IFCCLASSIFICATIONREFERENCE($,'13-51 14 23','Newborn Nursery',#327,$,$); +#334=IFCCLASSIFICATIONREFERENCE($,'13-51 14 25','NICU Nursery',#327,$,$); +#335=IFCCLASSIFICATIONREFERENCE($,'13-51 14 27','Nursery Transport Unit Alcove',#327,$,$); +#336=IFCCLASSIFICATIONREFERENCE($,'13-51 14 29','Nursery, Airborne Infection Isolation',#327,$,$); +#337=IFCCLASSIFICATIONREFERENCE($,'13-51 14 31','Nursery, Observation',#327,$,$); +#338=IFCCLASSIFICATIONREFERENCE($,'13-51 14 33','Nursery, Special Care',#327,$,$); +#339=IFCCLASSIFICATIONREFERENCE($,'13-51 14 35','Patient Room',#327,$,$); +#340=IFCCLASSIFICATIONREFERENCE($,'13-51 14 35 11','Patient Room, Airborne Infection Isolation',#339,$,$); +#341=IFCCLASSIFICATIONREFERENCE($,'13-51 14 35 13','Patient Room, Bariatric',#339,$,$); +#342=IFCCLASSIFICATIONREFERENCE($,'13-51 14 35 15','Patient Room, Intensive Care',#339,$,$); +#343=IFCCLASSIFICATIONREFERENCE($,'13-51 14 35 17','Patient Room, Intensive Care, Airborne Infection Isolation',#339,$,$); +#344=IFCCLASSIFICATIONREFERENCE($,'13-51 14 35 19','Patient Room, Intensive Care, Protective Environment Isolation',#339,$,$); +#345=IFCCLASSIFICATIONREFERENCE($,'13-51 14 35 21','Patient Room, Isolation',#339,$,$); +#346=IFCCLASSIFICATIONREFERENCE($,'13-51 14 35 23','Patient Room, Monitored',#339,$,$); +#347=IFCCLASSIFICATIONREFERENCE($,'13-51 14 35 25','Patient Room, One-Bed',#339,$,$); +#348=IFCCLASSIFICATIONREFERENCE($,'13-51 14 35 27','Patient Room, Protective Environment Isolation',#339,$,$); +#349=IFCCLASSIFICATIONREFERENCE($,'13-51 14 35 29','Patient Room, Seclusion',#339,$,$); +#350=IFCCLASSIFICATIONREFERENCE($,'13-51 14 35 31','Patient Room, Transitional, One-Bed',#339,$,$); +#351=IFCCLASSIFICATIONREFERENCE($,'13-51 14 35 33','Patient Room, Two-Bed',#339,$,$); +#352=IFCCLASSIFICATIONREFERENCE($,'13-51 17 00','Multi-Medical Service Support Spaces',#315,$,$); +#353=IFCCLASSIFICATIONREFERENCE($,'13-51 17 11','Clean Linen Storage Room, Healthcare',#352,$,$); +#354=IFCCLASSIFICATIONREFERENCE($,'13-51 17 13','Clean Supply Room, Healthcare',#352,$,$); +#355=IFCCLASSIFICATIONREFERENCE($,'13-51 17 15','Clean Utility Room, Healthcare',#352,$,$); +#356=IFCCLASSIFICATIONREFERENCE($,'13-51 17 17','Consultation Room, Patient',#352,$,$); +#357=IFCCLASSIFICATIONREFERENCE($,'13-51 17 19','Mental Health Interview/Counseling Room',#352,$,$); +#358=IFCCLASSIFICATIONREFERENCE($,'13-51 17 21','Equipment Storage Room, Healthcare',#352,$,$); +#359=IFCCLASSIFICATIONREFERENCE($,'13-51 17 22','Medical Records Storage Room',#352,$,$); +#360=IFCCLASSIFICATIONREFERENCE($,'13-51 17 23','Nurse Workspaces',#352,$,$); +#361=IFCCLASSIFICATIONREFERENCE($,'13-51 17 23 11','Nurse Station',#360,$,$); +#362=IFCCLASSIFICATIONREFERENCE($,'13-51 17 23 13','Nurse Station/Communication Center',#360,$,$); +#363=IFCCLASSIFICATIONREFERENCE($,'13-51 17 23 15','Nurse Sub-Station',#360,$,$); +#364=IFCCLASSIFICATIONREFERENCE($,'13-51 17 23 17','Nurse Triage Space',#360,$,$); +#365=IFCCLASSIFICATIONREFERENCE($,'13-51 17 25','Soiled Utility Room, Healthcare',#352,$,$); +#366=IFCCLASSIFICATIONREFERENCE($,'13-51 17 27','Soiled Utility/Supply Room, Healthcare',#352,$,$); +#367=IFCCLASSIFICATIONREFERENCE($,'13-51 17 29','Mental Health Multipurpose Room w/Control Room',#352,$,$); +#368=IFCCLASSIFICATIONREFERENCE($,'13-51 17 31','Resuscitation Cart Alcove',#352,$,$); +#369=IFCCLASSIFICATIONREFERENCE($,'13-51 17 35','Mental Health Quiet Room',#352,$,$); +#370=IFCCLASSIFICATIONREFERENCE($,'13-51 21 00','Diagnostic Imaging Spaces',#315,$,$); +#371=IFCCLASSIFICATIONREFERENCE($,'13-51 21 11','Angiographic Procedure Room',#370,$,$); +#372=IFCCLASSIFICATIONREFERENCE($,'13-51 21 13','Bone Densitometry Room',#370,$,$); +#373=IFCCLASSIFICATIONREFERENCE($,'13-51 21 15','CT Scanning Room',#370,$,$); +#374=IFCCLASSIFICATIONREFERENCE($,'13-51 21 17','CT Simulator Room',#370,$,$); +#375=IFCCLASSIFICATIONREFERENCE($,'13-51 21 19','Cystoscopic Radiology Room',#370,$,$); +#376=IFCCLASSIFICATIONREFERENCE($,'13-51 21 21','Head Radiographic Room',#370,$,$); +#377=IFCCLASSIFICATIONREFERENCE($,'13-51 21 23','Mammography Room',#370,$,$); +#378=IFCCLASSIFICATIONREFERENCE($,'13-51 21 25','Mobile Imaging System Alcove',#370,$,$); +#379=IFCCLASSIFICATIONREFERENCE($,'13-51 21 27','MRI Scanning Room',#370,$,$); +#380=IFCCLASSIFICATIONREFERENCE($,'13-51 21 29','MRI System Component Room',#370,$,$); +#381=IFCCLASSIFICATIONREFERENCE($,'13-51 21 31','PET/CT Scanning Room',#370,$,$); +#382=IFCCLASSIFICATIONREFERENCE($,'13-51 21 33','PET/CT Simulator Room',#370,$,$); +#383=IFCCLASSIFICATIONREFERENCE($,'13-51 21 35','Radiographic Chest Room',#370,$,$); +#384=IFCCLASSIFICATIONREFERENCE($,'13-51 21 37','Radiographic Room',#370,$,$); +#385=IFCCLASSIFICATIONREFERENCE($,'13-51 21 39','Radiographic/Fluoroscopic Room',#370,$,$); +#386=IFCCLASSIFICATIONREFERENCE($,'13-51 21 41','Radiographic/Tomographic Room',#370,$,$); +#387=IFCCLASSIFICATIONREFERENCE($,'13-51 21 43','Radiology Computer Systems Room',#370,$,$); +#388=IFCCLASSIFICATIONREFERENCE($,'13-51 21 45','Stereotactic Mammography Room',#370,$,$); +#389=IFCCLASSIFICATIONREFERENCE($,'13-51 21 47','Ultrasound Room',#370,$,$); +#390=IFCCLASSIFICATIONREFERENCE($,'13-51 21 49','Ultrasound/Optical Coherence Tomography Room',#370,$,$); +#391=IFCCLASSIFICATIONREFERENCE($,'13-51 21 51','Whole Body Scanning Room',#370,$,$); +#392=IFCCLASSIFICATIONREFERENCE($,'13-51 24 00','Diagnostic Imaging Support Spaces',#315,$,$); +#393=IFCCLASSIFICATIONREFERENCE($,'13-51 24 11','Angiographic Control Room',#392,$,$); +#394=IFCCLASSIFICATIONREFERENCE($,'13-51 24 13','Angiographic Instrument Room',#392,$,$); +#395=IFCCLASSIFICATIONREFERENCE($,'13-51 24 15','Angiographic Procedure Control Area',#392,$,$); +#396=IFCCLASSIFICATIONREFERENCE($,'13-51 24 17','Angiographic System Component Room',#392,$,$); +#397=IFCCLASSIFICATIONREFERENCE($,'13-51 24 19','Silver Collection Area, Diagnostic Imaging',#392,$,$); +#398=IFCCLASSIFICATIONREFERENCE($,'13-51 24 21','Computed Radiology Reader Area',#392,$,$); +#399=IFCCLASSIFICATIONREFERENCE($,'13-51 24 23','Computer Image Processing Area, Diagnostic Imaging',#392,$,$); +#400=IFCCLASSIFICATIONREFERENCE($,'13-51 24 24','X-Ray, Digital Image Storage Space',#392,$,$); +#401=IFCCLASSIFICATIONREFERENCE($,'13-51 24 25','CT Control Area',#392,$,$); +#402=IFCCLASSIFICATIONREFERENCE($,'13-51 24 27','CT Power and Equipment Room',#392,$,$); +#403=IFCCLASSIFICATIONREFERENCE($,'13-51 24 29','Image Quality Control Room',#392,$,$); +#404=IFCCLASSIFICATIONREFERENCE($,'13-51 24 31','Image Reading Room',#392,$,$); +#405=IFCCLASSIFICATIONREFERENCE($,'13-51 24 32','X-Ray, Plane Film Storage Space',#392,$,$); +#406=IFCCLASSIFICATIONREFERENCE($,'13-51 24 33','Mammography Processing Room',#392,$,$); +#407=IFCCLASSIFICATIONREFERENCE($,'13-51 24 34','X-Ray Film, Daylight Processing Space',#392,$,$); +#408=IFCCLASSIFICATIONREFERENCE($,'13-51 24 35','MRI Control Room',#392,$,$); +#409=IFCCLASSIFICATIONREFERENCE($,'13-51 24 37','MRI Equipment Storage Room',#392,$,$); +#410=IFCCLASSIFICATIONREFERENCE($,'13-51 24 39','MRI Viewing Room',#392,$,$); +#411=IFCCLASSIFICATIONREFERENCE($,'13-51 24 41','PET/CT Control Room',#392,$,$); +#412=IFCCLASSIFICATIONREFERENCE($,'13-51 24 43','Radiographic Control Room',#392,$,$); +#413=IFCCLASSIFICATIONREFERENCE($,'13-51 24 45','Radiographic Darkroom',#392,$,$); +#414=IFCCLASSIFICATIONREFERENCE($,'13-51 24 47','Tele-Radiology/Tele-Medicine Room',#392,$,$); +#415=IFCCLASSIFICATIONREFERENCE($,'13-51 24 49','Viewing/Consultation Room, Diagnostic Imaging',#392,$,$); +#416=IFCCLASSIFICATIONREFERENCE($,'13-51 24 51','X-Ray, Mobile C-Arm Alcove',#392,$,$); +#417=IFCCLASSIFICATIONREFERENCE($,'13-51 27 00','Radiation Diagnostic and Therapy Spaces',#315,$,$); +#418=IFCCLASSIFICATIONREFERENCE($,'13-51 27 11','Equipment Calibration Space, Radiation Diagnostic and Therapy',#417,$,$); +#419=IFCCLASSIFICATIONREFERENCE($,'13-51 27 13','Health Physics Laboratory',#417,$,$); +#420=IFCCLASSIFICATIONREFERENCE($,'13-51 27 15','Linear Accelerator Component Room, Healthcare',#417,$,$); +#421=IFCCLASSIFICATIONREFERENCE($,'13-51 27 17','Linear Accelerator Entrance Maze, Healthcare',#417,$,$); +#422=IFCCLASSIFICATIONREFERENCE($,'13-51 27 19','Linear Accelerator Room, Healthcare',#417,$,$); +#423=IFCCLASSIFICATIONREFERENCE($,'13-51 27 21','Linear Accelerator Control Room, Healthcare',#417,$,$); +#424=IFCCLASSIFICATIONREFERENCE($,'13-51 27 23','Radioactive Waste Storage Room, Healthcare',#417,$,$); +#425=IFCCLASSIFICATIONREFERENCE($,'13-51 27 25','Nuclear Medicine Dose Calibration Space',#417,$,$); +#426=IFCCLASSIFICATIONREFERENCE($,'13-51 27 27','Nuclear Medicine Scanning Room',#417,$,$); +#427=IFCCLASSIFICATIONREFERENCE($,'13-51 27 29','Nuclear Medicine Patient "Hot" Waiting Room',#417,$,$); +#428=IFCCLASSIFICATIONREFERENCE($,'13-51 27 31','Patient Dose/Thyroid Uptake Room',#417,$,$); +#429=IFCCLASSIFICATIONREFERENCE($,'13-51 27 33','Radiation Dosimetry Planning Room',#417,$,$); +#430=IFCCLASSIFICATIONREFERENCE($,'13-51 27 35','Radiopharmacy',#417,$,$); +#431=IFCCLASSIFICATIONREFERENCE($,'13-51 27 37','Radium Cart Holding Space',#417,$,$); +#432=IFCCLASSIFICATIONREFERENCE($,'13-51 27 38','Radiation Therapy, Mold Fabrication Shop',#417,$,$); +#433=IFCCLASSIFICATIONREFERENCE($,'13-51 27 39','Sealed Source Room',#417,$,$); +#434=IFCCLASSIFICATIONREFERENCE($,'13-51 31 00','Heart and Lung Diagnostic and Treatment Spaces',#315,$,$); +#435=IFCCLASSIFICATIONREFERENCE($,'13-51 31 11','Brachytherapy Room',#434,$,$); +#436=IFCCLASSIFICATIONREFERENCE($,'13-51 31 13','Cardiac Catheter Instrument Room',#434,$,$); +#437=IFCCLASSIFICATIONREFERENCE($,'13-51 31 15','Cardiac Catheter System Component Room',#434,$,$); +#438=IFCCLASSIFICATIONREFERENCE($,'13-51 31 17','Cardiac Catheterization Control Room',#434,$,$); +#439=IFCCLASSIFICATIONREFERENCE($,'13-51 31 19','Cardiac Catheterization Laboratory',#434,$,$); +#440=IFCCLASSIFICATIONREFERENCE($,'13-51 31 21','Cardiac Electrophysiology Room',#434,$,$); +#441=IFCCLASSIFICATIONREFERENCE($,'13-51 31 23','Cardiac Testing Room',#434,$,$); +#442=IFCCLASSIFICATIONREFERENCE($,'13-51 31 25','Echocardiograph Room',#434,$,$); +#443=IFCCLASSIFICATIONREFERENCE($,'13-51 31 27','EKG Testing Room',#434,$,$); +#444=IFCCLASSIFICATIONREFERENCE($,'13-51 31 29','Extended Pulmonary Function Testing Laboratory',#434,$,$); +#445=IFCCLASSIFICATIONREFERENCE($,'13-51 31 31','Microvascular Laboratory',#434,$,$); +#446=IFCCLASSIFICATIONREFERENCE($,'13-51 31 33','Pacemaker ICD Interrogation Room',#434,$,$); +#447=IFCCLASSIFICATIONREFERENCE($,'13-51 31 35','Pacemaker/Holter Monitor Room',#434,$,$); +#448=IFCCLASSIFICATIONREFERENCE($,'13-51 31 37','Procedure Viewing Area',#434,$,$); +#449=IFCCLASSIFICATIONREFERENCE($,'13-51 31 39','Pulmonary Function Testing Laboratory',#434,$,$); +#450=IFCCLASSIFICATIONREFERENCE($,'13-51 31 40','Pulmonary Function Treadmill Room',#434,$,$); +#451=IFCCLASSIFICATIONREFERENCE($,'13-51 31 41','Pulmonary Screening Room',#434,$,$); +#452=IFCCLASSIFICATIONREFERENCE($,'13-51 31 43','Respiratory Inhalation Cubicle',#434,$,$); +#453=IFCCLASSIFICATIONREFERENCE($,'13-51 31 45','Respiratory Therapy Clean-up Room',#434,$,$); +#454=IFCCLASSIFICATIONREFERENCE($,'13-51 31 47','Spirometry Test Room',#434,$,$); +#455=IFCCLASSIFICATIONREFERENCE($,'13-51 31 49','Stress Echocardiograph Room',#434,$,$); +#456=IFCCLASSIFICATIONREFERENCE($,'13-51 31 51','Stress Testing Treadmill Room',#434,$,$); +#457=IFCCLASSIFICATIONREFERENCE($,'13-51 31 53','Transesophageal Echocardiography Room',#434,$,$); +#458=IFCCLASSIFICATIONREFERENCE($,'13-51 34 00','General Diagnostic Procedure and Treatment Spaces',#315,$,$); +#459=IFCCLASSIFICATIONREFERENCE($,'13-51 34 11','Allergen Preparation Space',#458,$,$); +#460=IFCCLASSIFICATIONREFERENCE($,'13-51 34 13','Allergy Injection Room',#458,$,$); +#461=IFCCLASSIFICATIONREFERENCE($,'13-51 34 15','Allergy Skin Testing',#458,$,$); +#462=IFCCLASSIFICATIONREFERENCE($,'13-51 34 17','Antepartum Testing (NST) Room',#458,$,$); +#463=IFCCLASSIFICATIONREFERENCE($,'13-51 34 19','Biofeedback Treatment Control/Office',#458,$,$); +#464=IFCCLASSIFICATIONREFERENCE($,'13-51 34 21','Biofeedback Treatment Room',#458,$,$); +#465=IFCCLASSIFICATIONREFERENCE($,'13-51 34 23','Cast and Splint Room',#458,$,$); +#466=IFCCLASSIFICATIONREFERENCE($,'13-51 34 25','Chemotherapy Treatment Room',#458,$,$); +#467=IFCCLASSIFICATIONREFERENCE($,'13-51 34 27','Dermatology Cryotherapy Space',#458,$,$); +#468=IFCCLASSIFICATIONREFERENCE($,'13-51 34 29','Dermatology Procedure Room',#458,$,$); +#469=IFCCLASSIFICATIONREFERENCE($,'13-51 34 31','Dialysis Clean Equipment Preparation Room',#458,$,$); +#470=IFCCLASSIFICATIONREFERENCE($,'13-51 34 33','Dialysis Soiled Equipment Processing',#458,$,$); +#471=IFCCLASSIFICATIONREFERENCE($,'13-51 34 35','Dialysis Training Room',#458,$,$); +#472=IFCCLASSIFICATIONREFERENCE($,'13-51 34 37','EEG Exam Room',#458,$,$); +#473=IFCCLASSIFICATIONREFERENCE($,'13-51 34 39','EEG Instrument and Work Room',#458,$,$); +#474=IFCCLASSIFICATIONREFERENCE($,'13-51 34 41','EEG/Sleep Study Monitoring Room',#458,$,$); +#475=IFCCLASSIFICATIONREFERENCE($,'13-51 34 43','Electromyography Room',#458,$,$); +#476=IFCCLASSIFICATIONREFERENCE($,'13-51 34 45','ENT Procedure Room',#458,$,$); +#477=IFCCLASSIFICATIONREFERENCE($,'13-51 34 47','Evoked Potential Response Room',#458,$,$); +#478=IFCCLASSIFICATIONREFERENCE($,'13-51 34 49','General Purpose Dirty Treatment Room',#458,$,$); +#479=IFCCLASSIFICATIONREFERENCE($,'13-51 34 51','Immunization Room',#458,$,$); +#480=IFCCLASSIFICATIONREFERENCE($,'13-51 34 53','Infectious Disease Decontamination Shower',#458,$,$); +#481=IFCCLASSIFICATIONREFERENCE($,'13-51 34 55','Infectious Disease Decontamination Suite',#458,$,$); +#482=IFCCLASSIFICATIONREFERENCE($,'13-51 34 57','Life Support Unit Room',#458,$,$); +#483=IFCCLASSIFICATIONREFERENCE($,'13-51 34 61','OB/GYN Treatment Room',#458,$,$); +#484=IFCCLASSIFICATIONREFERENCE($,'13-51 34 63','Patient Observation and Treatment Room',#458,$,$); +#485=IFCCLASSIFICATIONREFERENCE($,'13-51 34 65','Pentamidine Treatment Room',#458,$,$); +#486=IFCCLASSIFICATIONREFERENCE($,'13-51 34 67','Peritoneal Dialysis Exam Room',#458,$,$); +#487=IFCCLASSIFICATIONREFERENCE($,'13-51 34 69','Peritoneal Dialysis Procedure Room',#458,$,$); +#488=IFCCLASSIFICATIONREFERENCE($,'13-51 34 71','Phototherapy Treatment Room',#458,$,$); +#489=IFCCLASSIFICATIONREFERENCE($,'13-51 34 73','Renal Dialysis Bed Station, Private',#458,$,$); +#490=IFCCLASSIFICATIONREFERENCE($,'13-51 34 75','Renal Dialysis Room, Negative Pressure',#458,$,$); +#491=IFCCLASSIFICATIONREFERENCE($,'13-51 34 77','Renal Dialysis, Chair Station, Cubicle',#458,$,$); +#492=IFCCLASSIFICATIONREFERENCE($,'13-51 34 78','Renal Dialysis, Water Treatment Room',#458,$,$); +#493=IFCCLASSIFICATIONREFERENCE($,'13-51 34 79','Sleep Study Room',#458,$,$); +#494=IFCCLASSIFICATIONREFERENCE($,'13-51 34 81','Provider Trainee Observation Area, Healthcare',#458,$,$); +#495=IFCCLASSIFICATIONREFERENCE($,'13-51 34 83','Treatment Cubicle, Healthcare',#458,$,$); +#496=IFCCLASSIFICATIONREFERENCE($,'13-51 34 85','Treatment Room, Healthcare',#458,$,$); +#497=IFCCLASSIFICATIONREFERENCE($,'13-51 34 87','Neuropsychology Testing Laboratory',#458,$,$); +#498=IFCCLASSIFICATIONREFERENCE($,'13-51 37 00','Eye and Ear Healthcare Spaces',#315,$,$); +#499=IFCCLASSIFICATIONREFERENCE($,'13-51 37 11','Audiology Immittance Room',#498,$,$); +#500=IFCCLASSIFICATIONREFERENCE($,'13-51 37 13','Audiometric Exam Booth',#498,$,$); +#501=IFCCLASSIFICATIONREFERENCE($,'13-51 37 15','Audiometric Exam Suite',#498,$,$); +#502=IFCCLASSIFICATIONREFERENCE($,'13-51 37 17','Audiometric Multi-Exam Suite',#498,$,$); +#503=IFCCLASSIFICATIONREFERENCE($,'13-51 37 19','Audiology Electrophysiology Exam Room',#498,$,$); +#504=IFCCLASSIFICATIONREFERENCE($,'13-51 37 20','Hearing Aid Testing Laboratory',#498,$,$); +#505=IFCCLASSIFICATIONREFERENCE($,'13-51 37 21','Electroretinography Room',#498,$,$); +#506=IFCCLASSIFICATIONREFERENCE($,'13-51 37 23','ENT Exam Room',#498,$,$); +#507=IFCCLASSIFICATIONREFERENCE($,'13-51 37 25','Exam/Training Room, Low Vision',#498,$,$); +#508=IFCCLASSIFICATIONREFERENCE($,'13-51 37 27','Eye Lane',#498,$,$); +#509=IFCCLASSIFICATIONREFERENCE($,'13-51 37 29','Laser Treatment Room',#498,$,$); +#510=IFCCLASSIFICATIONREFERENCE($,'13-51 37 31','Ophthalmology Procedure Room',#498,$,$); +#511=IFCCLASSIFICATIONREFERENCE($,'13-51 37 33','Ophthalmology/Optometry Exam Room',#498,$,$); +#512=IFCCLASSIFICATIONREFERENCE($,'13-51 37 35','Photography Room, Ophthalmology/Optometry',#498,$,$); +#513=IFCCLASSIFICATIONREFERENCE($,'13-51 37 37','PRK/LASIK Treatment Room',#498,$,$); +#514=IFCCLASSIFICATIONREFERENCE($,'13-51 37 39','Sinusoidal Vertical Axis Rotational Rest Room',#498,$,$); +#515=IFCCLASSIFICATIONREFERENCE($,'13-51 37 41','Tilt Table Testing Room',#498,$,$); +#516=IFCCLASSIFICATIONREFERENCE($,'13-51 37 43','Training Room, Low Vision, Polytrauma',#498,$,$); +#517=IFCCLASSIFICATIONREFERENCE($,'13-51 37 45','Ultrasound/Optical Coherence Tomography Room',#498,$,$); +#518=IFCCLASSIFICATIONREFERENCE($,'13-51 37 47','Vestibulography Room',#498,$,$); +#519=IFCCLASSIFICATIONREFERENCE($,'13-51 37 49','Vision/Hearing Screening Room',#498,$,$); +#520=IFCCLASSIFICATIONREFERENCE($,'13-51 37 51','Vision Screening Room',#498,$,$); +#521=IFCCLASSIFICATIONREFERENCE($,'13-51 37 53','Vision Testing Station',#498,$,$); +#522=IFCCLASSIFICATIONREFERENCE($,'13-51 37 55','Visual Fields Room',#498,$,$); +#523=IFCCLASSIFICATIONREFERENCE($,'13-51 37 57','Eye, Contact Lens Fitting/Dispensing Space',#498,$,$); +#524=IFCCLASSIFICATIONREFERENCE($,'13-51 37 59','Eyeglass Fitting and Dispensing Space',#498,$,$); +#525=IFCCLASSIFICATIONREFERENCE($,'13-51 41 00','Endoscopy/Gastroenterology Spaces',#315,$,$); +#526=IFCCLASSIFICATIONREFERENCE($,'13-51 41 11','Bronchoscopy Equipment Preparation Room',#525,$,$); +#527=IFCCLASSIFICATIONREFERENCE($,'13-51 41 13','Bronchoscopy Procedure Room',#525,$,$); +#528=IFCCLASSIFICATIONREFERENCE($,'13-51 41 15','Endoscope Clean-up, Sterilization, and Storage Room',#525,$,$); +#529=IFCCLASSIFICATIONREFERENCE($,'13-51 41 17','Endoscopy Room',#525,$,$); +#530=IFCCLASSIFICATIONREFERENCE($,'13-51 41 19','Gastroenterology Laboratory',#525,$,$); +#531=IFCCLASSIFICATIONREFERENCE($,'13-51 41 21','Proctoscopy/Sigmoidoscopy Room',#525,$,$); +#532=IFCCLASSIFICATIONREFERENCE($,'13-51 41 23','Urodynamics Treatment Room',#525,$,$); +#533=IFCCLASSIFICATIONREFERENCE($,'13-51 44 00','Surgical Spaces',#315,$,$); +#534=IFCCLASSIFICATIONREFERENCE($,'13-51 44 11','Anesthesia Workroom and Equipment Storage',#533,$,$); +#535=IFCCLASSIFICATIONREFERENCE($,'13-51 44 13','Cardiac Operating Room',#533,$,$); +#536=IFCCLASSIFICATIONREFERENCE($,'13-51 44 15','Cardiac Pump Room',#533,$,$); +#537=IFCCLASSIFICATIONREFERENCE($,'13-51 44 17','Cesarean Birth Room',#533,$,$); +#538=IFCCLASSIFICATIONREFERENCE($,'13-51 44 19','Cystoscopy Room',#533,$,$); +#539=IFCCLASSIFICATIONREFERENCE($,'13-51 44 21','Equipment Storage Room, Surgical',#533,$,$); +#540=IFCCLASSIFICATIONREFERENCE($,'13-51 44 23','Frozen Section Laboratory',#533,$,$); +#541=IFCCLASSIFICATIONREFERENCE($,'13-51 44 25','General Operating Room',#533,$,$); +#542=IFCCLASSIFICATIONREFERENCE($,'13-51 44 27','Nerve Block Induction Room',#533,$,$); +#543=IFCCLASSIFICATIONREFERENCE($,'13-51 44 29','Neurosurgery Operating Room',#533,$,$); +#544=IFCCLASSIFICATIONREFERENCE($,'13-51 44 31','Orthopedic Operating Room',#533,$,$); +#545=IFCCLASSIFICATIONREFERENCE($,'13-51 44 33','Patient Holding Area, Surgical',#533,$,$); +#546=IFCCLASSIFICATIONREFERENCE($,'13-51 44 35','Postanesthesia Recovery Cubicle',#533,$,$); +#547=IFCCLASSIFICATIONREFERENCE($,'13-51 44 37','Postanesthesia Recovery Isolation Room',#533,$,$); +#548=IFCCLASSIFICATIONREFERENCE($,'13-51 44 39','Postoperative Recovery Lounge',#533,$,$); +#549=IFCCLASSIFICATIONREFERENCE($,'13-51 44 41','Preparation/Recovery Spaces, Surgical',#533,$,$); +#550=IFCCLASSIFICATIONREFERENCE($,'13-51 44 41 11','Preparation/Recovery Cubicle, Surgical',#549,$,$); +#551=IFCCLASSIFICATIONREFERENCE($,'13-51 44 41 13','Preparation/Recovery Room, Surgical',#549,$,$); +#552=IFCCLASSIFICATIONREFERENCE($,'13-51 44 43','Procedure/Minor Operating Room',#533,$,$); +#553=IFCCLASSIFICATIONREFERENCE($,'13-51 44 45','Scrub/Gowning Area',#533,$,$); +#554=IFCCLASSIFICATIONREFERENCE($,'13-51 44 47','Sub-Sterile Room',#533,$,$); +#555=IFCCLASSIFICATIONREFERENCE($,'13-51 44 50','Operating Room, Sterile Storage',#533,$,$); +#556=IFCCLASSIFICATIONREFERENCE($,'13-51 44 51','Surgical Laser Treatment Room',#533,$,$); +#557=IFCCLASSIFICATIONREFERENCE($,'13-51 44 53','Recovery Room, Surgical',#533,$,$); +#558=IFCCLASSIFICATIONREFERENCE($,'13-51 44 55','Surgical Suite, Workroom and Supply Space',#533,$,$); +#559=IFCCLASSIFICATIONREFERENCE($,'13-51 47 00','Clinical Laboratory Spaces',#315,$,$); +#560=IFCCLASSIFICATIONREFERENCE($,'13-51 47 11','Automated Clinical Laboratory',#559,$,$); +#561=IFCCLASSIFICATIONREFERENCE($,'13-51 47 13','Bioassay (Radioimmunoassay) Room',#559,$,$); +#562=IFCCLASSIFICATIONREFERENCE($,'13-51 47 15','Blood Gas Laboratory',#559,$,$); +#563=IFCCLASSIFICATIONREFERENCE($,'13-51 47 17','Blood Hemotherapeutics Room',#559,$,$); +#564=IFCCLASSIFICATIONREFERENCE($,'13-51 47 19','Bone Dissection Laboratory',#559,$,$); +#565=IFCCLASSIFICATIONREFERENCE($,'13-51 47 21','Clinical Chemistry Laboratory',#559,$,$); +#566=IFCCLASSIFICATIONREFERENCE($,'13-51 47 23','Clinical Microbiology Laboratory',#559,$,$); +#567=IFCCLASSIFICATIONREFERENCE($,'13-51 47 25','Cytology Laboratory',#559,$,$); +#568=IFCCLASSIFICATIONREFERENCE($,'13-51 47 27','Cytology Screening and Histology Space',#559,$,$); +#569=IFCCLASSIFICATIONREFERENCE($,'13-51 47 29','Dermatology Laboratory',#559,$,$); +#570=IFCCLASSIFICATIONREFERENCE($,'13-51 47 31','Electron Microscope Suite',#559,$,$); +#571=IFCCLASSIFICATIONREFERENCE($,'13-51 47 33','Electron Microscope System Room',#559,$,$); +#572=IFCCLASSIFICATIONREFERENCE($,'13-51 47 35','Entomology Laboratory',#559,$,$); +#573=IFCCLASSIFICATIONREFERENCE($,'13-51 47 37','Flow Cytometer Space',#559,$,$); +#574=IFCCLASSIFICATIONREFERENCE($,'13-51 47 39','Fluorescence Microscope Room',#559,$,$); +#575=IFCCLASSIFICATIONREFERENCE($,'13-51 47 41','General Clinical Laboratory Area',#559,$,$); +#576=IFCCLASSIFICATIONREFERENCE($,'13-51 47 43','Hematology Laboratory, Coagulation',#559,$,$); +#577=IFCCLASSIFICATIONREFERENCE($,'13-51 47 45','Hematology Laboratory, Routine',#559,$,$); +#578=IFCCLASSIFICATIONREFERENCE($,'13-51 47 47','Histology Laboratory',#559,$,$); +#579=IFCCLASSIFICATIONREFERENCE($,'13-51 47 49','Immunopathology Laboratory',#559,$,$); +#580=IFCCLASSIFICATIONREFERENCE($,'13-51 47 51','Microbiology Biosafety Laboratory',#559,$,$); +#581=IFCCLASSIFICATIONREFERENCE($,'13-51 47 53','Microbiology Mycology Laboratory',#559,$,$); +#582=IFCCLASSIFICATIONREFERENCE($,'13-51 47 55','Microbiology Mycobacteriology Laboratory',#559,$,$); +#583=IFCCLASSIFICATIONREFERENCE($,'13-51 47 57','Moh''s Laboratory',#559,$,$); +#584=IFCCLASSIFICATIONREFERENCE($,'13-51 47 59','Mycology Laboratory',#559,$,$); +#585=IFCCLASSIFICATIONREFERENCE($,'13-51 47 61','Nephrology Renal Study Space',#559,$,$); +#586=IFCCLASSIFICATIONREFERENCE($,'13-51 47 63','Renal Studies Laboratory',#559,$,$); +#587=IFCCLASSIFICATIONREFERENCE($,'13-51 47 65','Special Chemistry Laboratory',#559,$,$); +#588=IFCCLASSIFICATIONREFERENCE($,'13-51 47 67','Urine Testing Alcove',#559,$,$); +#589=IFCCLASSIFICATIONREFERENCE($,'13-51 47 69','Urinalysis Laboratory',#559,$,$); +#590=IFCCLASSIFICATIONREFERENCE($,'13-51 47 71','Urology Laboratory',#559,$,$); +#591=IFCCLASSIFICATIONREFERENCE($,'13-51 47 73','Medical Autopsy Room',#559,$,$); +#592=IFCCLASSIFICATIONREFERENCE($,'13-51 51 00','Clinical Laboratory Support Spaces',#315,$,$); +#593=IFCCLASSIFICATIONREFERENCE($,'13-51 51 11','Blood Bank Donor Station',#592,$,$); +#594=IFCCLASSIFICATIONREFERENCE($,'13-51 51 13','Blood Bank Preparation Rom',#592,$,$); +#595=IFCCLASSIFICATIONREFERENCE($,'13-51 51 15','Blood Bank Blood Product Storage Space',#592,$,$); +#596=IFCCLASSIFICATIONREFERENCE($,'13-51 51 17','Blood Bank Storage and Transfusion Room',#592,$,$); +#597=IFCCLASSIFICATIONREFERENCE($,'13-51 51 19','Blood Specimen Collection Room',#592,$,$); +#598=IFCCLASSIFICATIONREFERENCE($,'13-51 51 21','Cell Bank Freezer, Ultra Low',#592,$,$); +#599=IFCCLASSIFICATIONREFERENCE($,'13-51 51 23','Electron Microscope Automated Data Processing Room',#592,$,$); +#600=IFCCLASSIFICATIONREFERENCE($,'13-51 51 25','Electron Microscope Cutting Room',#592,$,$); +#601=IFCCLASSIFICATIONREFERENCE($,'13-51 51 27','Electron Microscope Dark Room',#592,$,$); +#602=IFCCLASSIFICATIONREFERENCE($,'13-51 51 29','Electron Microscope Developing, Printing and Enlarging Room',#592,$,$); +#603=IFCCLASSIFICATIONREFERENCE($,'13-51 51 31','Electron Microscope Finishing Room',#592,$,$); +#604=IFCCLASSIFICATIONREFERENCE($,'13-51 51 33','Electron Microscope Preparation Room',#592,$,$); +#605=IFCCLASSIFICATIONREFERENCE($,'13-51 51 35','Glassware Washing and Decontamination Room, Clinical Laboratory',#592,$,$); +#606=IFCCLASSIFICATIONREFERENCE($,'13-51 51 37','Glassware Washing Room, Clinical Laboratory',#592,$,$); +#607=IFCCLASSIFICATIONREFERENCE($,'13-51 51 39','Slides and Blocks Storage Room, Clinical Laboratory',#592,$,$); +#608=IFCCLASSIFICATIONREFERENCE($,'13-51 51 41','Sterilization and Solution Preparation Room, Clinical Laboratory',#592,$,$); +#609=IFCCLASSIFICATIONREFERENCE($,'13-51 51 43','Tissue Storage Area, Clinical Laboratory',#592,$,$); +#610=IFCCLASSIFICATIONREFERENCE($,'13-51 51 45','Microbiology Media Preparation Laboratory',#592,$,$); +#611=IFCCLASSIFICATIONREFERENCE($,'13-51 51 47','Specimen Accessioning, Processing and Distribution Room',#592,$,$); +#612=IFCCLASSIFICATIONREFERENCE($,'13-51 51 49','Laboratory, Water',#592,$,$); +#613=IFCCLASSIFICATIONREFERENCE($,'13-51 54 00','Pharmacy Spaces',#315,$,$); +#614=IFCCLASSIFICATIONREFERENCE($,'13-51 54 11','Chemotherapy Agent Medication Preparation Room',#613,$,$); +#615=IFCCLASSIFICATIONREFERENCE($,'13-51 54 13','Compound Sterile Preparation Space - High Risk',#613,$,$); +#616=IFCCLASSIFICATIONREFERENCE($,'13-51 54 15','Compound Sterile Preparation Space - Low Risk',#613,$,$); +#617=IFCCLASSIFICATIONREFERENCE($,'13-51 54 17','Compounding Area',#613,$,$); +#618=IFCCLASSIFICATIONREFERENCE($,'13-51 54 19','Dialysate Preparation Room',#613,$,$); +#619=IFCCLASSIFICATIONREFERENCE($,'13-51 54 21','IV Admixture Anteroom',#613,$,$); +#620=IFCCLASSIFICATIONREFERENCE($,'13-51 54 23','IV Admixture Room',#613,$,$); +#621=IFCCLASSIFICATIONREFERENCE($,'13-51 54 25','Medication Preparation Room',#613,$,$); +#622=IFCCLASSIFICATIONREFERENCE($,'13-51 54 27','Methadone Dispensing Station',#613,$,$); +#623=IFCCLASSIFICATIONREFERENCE($,'13-51 54 29','Oncology Drug Preparation Area',#613,$,$); +#624=IFCCLASSIFICATIONREFERENCE($,'13-51 54 31','Pharmacy',#613,$,$); +#625=IFCCLASSIFICATIONREFERENCE($,'13-51 54 32','Pharmacy, Dispensing Space',#613,$,$); +#626=IFCCLASSIFICATIONREFERENCE($,'13-51 54 33','Pharmacy Manufacturing & Prepack Space',#613,$,$); +#627=IFCCLASSIFICATIONREFERENCE($,'13-51 54 35','Prescription Receiving Station',#613,$,$); +#628=IFCCLASSIFICATIONREFERENCE($,'13-51 54 37','Pharmacy, Bulk, Breakdown and Verification Area',#613,$,$); +#629=IFCCLASSIFICATIONREFERENCE($,'13-51 54 39','Pharmacy, Controlled Substances and Secured Dispensing',#613,$,$); +#630=IFCCLASSIFICATIONREFERENCE($,'13-51 57 00','Medical Services Logistic Spaces',#315,$,$); +#631=IFCCLASSIFICATIONREFERENCE($,'13-51 57 11','Automatic Cart Wash Area, Healthcare',#630,$,$); +#632=IFCCLASSIFICATIONREFERENCE($,'13-51 57 13','BSL3 Infectious Disease Suite, Autoclave Room',#630,$,$); +#633=IFCCLASSIFICATIONREFERENCE($,'13-51 57 15','BSL3 Suite, Autoclave Room',#630,$,$); +#634=IFCCLASSIFICATIONREFERENCE($,'13-51 57 17','Cart Assembly/Queue Area, Healthcare',#630,$,$); +#635=IFCCLASSIFICATIONREFERENCE($,'13-51 57 19','Clean Cart Holding Area, Healthcare',#630,$,$); +#636=IFCCLASSIFICATIONREFERENCE($,'13-51 57 20','Medical Material Cart Restocking Area',#630,$,$); +#637=IFCCLASSIFICATIONREFERENCE($,'13-51 57 21','Clean Linen Preparation and Storage Area, Healthcare',#630,$,$); +#638=IFCCLASSIFICATIONREFERENCE($,'13-51 57 23','Clean Supply Preparation and Assembly Area, Healthcare',#630,$,$); +#639=IFCCLASSIFICATIONREFERENCE($,'13-51 57 25','Clean Supply Preparation Area, Healthcare',#630,$,$); +#640=IFCCLASSIFICATIONREFERENCE($,'13-51 57 27','Equipment Processing and Clean Storage Room, Healthcare',#630,$,$); +#641=IFCCLASSIFICATIONREFERENCE($,'13-51 57 29','Ethylene Oxide Gas Sterilizer Room',#630,$,$); +#642=IFCCLASSIFICATIONREFERENCE($,'13-51 57 31','Instrument Sterilization Room',#630,$,$); +#643=IFCCLASSIFICATIONREFERENCE($,'13-51 57 32','Central Sterile, Receiving and Decontamination',#630,$,$); +#644=IFCCLASSIFICATIONREFERENCE($,'13-51 57 33','Manual Cart Wash Area, Healthcare',#630,$,$); +#645=IFCCLASSIFICATIONREFERENCE($,'13-51 57 35','Soiled Cart Holding Area, Healthcare',#630,$,$); +#646=IFCCLASSIFICATIONREFERENCE($,'13-51 57 37','Soiled Cart Receiving Area, Healthcare',#630,$,$); +#647=IFCCLASSIFICATIONREFERENCE($,'13-51 57 39','Soiled Instrument and Equipment Receiving and Decontamination Room, Healthcare',#630,$,$); +#648=IFCCLASSIFICATIONREFERENCE($,'13-51 57 41','Sterile Supply Preparation and Assembly Area, Healthcare',#630,$,$); +#649=IFCCLASSIFICATIONREFERENCE($,'13-51 57 43','Biomedical Electronic Repair',#630,$,$); +#650=IFCCLASSIFICATIONREFERENCE($,'13-51 61 00','Rehabilitation Spaces',#315,$,$); +#651=IFCCLASSIFICATIONREFERENCE($,'13-51 61 11','Amputee Training Area',#650,$,$); +#652=IFCCLASSIFICATIONREFERENCE($,'13-51 61 13','Brace Shop Fitting Shop',#650,$,$); +#653=IFCCLASSIFICATIONREFERENCE($,'13-51 61 15','Brace Shop , Adjustment/Modification Area',#650,$,$); +#654=IFCCLASSIFICATIONREFERENCE($,'13-51 61 17','Brace Shop Welding Area',#650,$,$); +#655=IFCCLASSIFICATIONREFERENCE($,'13-51 61 19','Computer Activities Room, Rehabilitation',#650,$,$); +#656=IFCCLASSIFICATIONREFERENCE($,'13-51 61 21','Prosthesis Design and Manufacturing Room, Rehabilitation',#650,$,$); +#657=IFCCLASSIFICATIONREFERENCE($,'13-51 61 23','Dynamic Alignment Room',#650,$,$); +#658=IFCCLASSIFICATIONREFERENCE($,'13-51 61 25','Therapeutic Exercise Spaces',#650,$,$); +#659=IFCCLASSIFICATIONREFERENCE($,'13-51 61 25 11','Therapeutic Exercise Area',#658,$,$); +#660=IFCCLASSIFICATIONREFERENCE($,'13-51 61 25 13','Exercise/Therapy Gymnasium',#658,$,$); +#661=IFCCLASSIFICATIONREFERENCE($,'13-51 61 25 15','Individual Therapeutic Exercise Area',#658,$,$); +#662=IFCCLASSIFICATIONREFERENCE($,'13-51 61 25 17','Treatment/Exercise Area',#658,$,$); +#663=IFCCLASSIFICATIONREFERENCE($,'13-51 61 27','Eye Fitting Studio',#650,$,$); +#664=IFCCLASSIFICATIONREFERENCE($,'13-51 61 29','Facial/Body Fitting Studio',#650,$,$); +#665=IFCCLASSIFICATIONREFERENCE($,'13-51 61 31','Fitting Room, Custom Fabrication',#650,$,$); +#666=IFCCLASSIFICATIONREFERENCE($,'13-51 61 33','Fitting Room, Soft Goods Fabrication',#650,$,$); +#667=IFCCLASSIFICATIONREFERENCE($,'13-51 61 35','Gait Lane',#650,$,$); +#668=IFCCLASSIFICATIONREFERENCE($,'13-51 61 37','Gait Study Track',#650,$,$); +#669=IFCCLASSIFICATIONREFERENCE($,'13-51 61 39','Hearing Aid Fabrication and Modification Room',#650,$,$); +#670=IFCCLASSIFICATIONREFERENCE($,'13-51 61 41','Hubbard Tank - Full Immersion',#650,$,$); +#671=IFCCLASSIFICATIONREFERENCE($,'13-51 61 43','Hubbard Tank - Partial Immersion',#650,$,$); +#672=IFCCLASSIFICATIONREFERENCE($,'13-51 61 45','Hydrotherapy Area',#650,$,$); +#673=IFCCLASSIFICATIONREFERENCE($,'13-51 61 47','Neurophysiology Rehabilitation Room',#650,$,$); +#674=IFCCLASSIFICATIONREFERENCE($,'13-51 61 49','Occupational Therapy Room',#650,$,$); +#675=IFCCLASSIFICATIONREFERENCE($,'13-51 61 50','Occupational Therapy, Daily Living Skills Training and Evaluation Room',#650,$,$); +#676=IFCCLASSIFICATIONREFERENCE($,'13-51 61 51','Pediatric Developmental Therapy Space',#650,$,$); +#677=IFCCLASSIFICATIONREFERENCE($,'13-51 61 53','Physical Therapy/Kinesiology Therapy Room',#650,$,$); +#678=IFCCLASSIFICATIONREFERENCE($,'13-51 61 55','Posturography Exam Room',#650,$,$); +#679=IFCCLASSIFICATIONREFERENCE($,'13-51 61 57','Prosthetic and Orthotic Dust Room',#650,$,$); +#680=IFCCLASSIFICATIONREFERENCE($,'13-51 61 59','Prosthetic and Orthotic Fume Room',#650,$,$); +#681=IFCCLASSIFICATIONREFERENCE($,'13-51 61 61','Prosthetic and Orthotic Work Station',#650,$,$); +#682=IFCCLASSIFICATIONREFERENCE($,'13-51 61 63','Prosthetic and Orthotic, Maintenance Support Room',#650,$,$); +#683=IFCCLASSIFICATIONREFERENCE($,'13-51 61 65','Rehabilitation Therapy Gym',#650,$,$); +#684=IFCCLASSIFICATIONREFERENCE($,'13-51 61 67','Speech Pathology Individual Therapy Room',#650,$,$); +#685=IFCCLASSIFICATIONREFERENCE($,'13-51 61 68','Speech Therapist, Exam and Treatment Space',#650,$,$); +#686=IFCCLASSIFICATIONREFERENCE($,'13-51 61 69','Therapeutic Pool',#650,$,$); +#687=IFCCLASSIFICATIONREFERENCE($,'13-51 61 71','Wheelchair Repair Workspace',#650,$,$); +#688=IFCCLASSIFICATIONREFERENCE($,'13-51 61 73','Whirlpool',#650,$,$); +#689=IFCCLASSIFICATIONREFERENCE($,'13-51 61 75','Rehabilitation Living Skills Training Apartment',#650,$,$); +#690=IFCCLASSIFICATIONREFERENCE($,'13-51 64 00','Dental Spaces',#315,$,$); +#691=IFCCLASSIFICATIONREFERENCE($,'13-51 64 11','Dental CS Suite',#690,$,$); +#692=IFCCLASSIFICATIONREFERENCE($,'13-51 64 13','Dental Hygiene and Operatory Room',#690,$,$); +#693=IFCCLASSIFICATIONREFERENCE($,'13-51 64 15','Dental Hygiene Room',#690,$,$); +#694=IFCCLASSIFICATIONREFERENCE($,'13-51 64 17','Dental Porcelain Room',#690,$,$); +#695=IFCCLASSIFICATIONREFERENCE($,'13-51 64 19','Dental Prosthetics Laboratory',#690,$,$); +#696=IFCCLASSIFICATIONREFERENCE($,'13-51 64 21','Dental Screening Room',#690,$,$); +#697=IFCCLASSIFICATIONREFERENCE($,'13-51 64 23','Dental Self Preparation Area',#690,$,$); +#698=IFCCLASSIFICATIONREFERENCE($,'13-51 64 25','Dental Treatment t Room, Mini Laboratory',#690,$,$); +#699=IFCCLASSIFICATIONREFERENCE($,'13-51 64 27','Dental Treatment Room',#690,$,$); +#700=IFCCLASSIFICATIONREFERENCE($,'13-51 64 29','Dental Treatment Room, Conscious Sedation Support',#690,$,$); +#701=IFCCLASSIFICATIONREFERENCE($,'13-51 64 31','Dental Treatment Room, Endodontics',#690,$,$); +#702=IFCCLASSIFICATIONREFERENCE($,'13-51 64 33','Dental Treatment Room, Orthodontics',#690,$,$); +#703=IFCCLASSIFICATIONREFERENCE($,'13-51 64 35','Dental Treatment Room, Pediatrics',#690,$,$); +#704=IFCCLASSIFICATIONREFERENCE($,'13-51 64 37','Dental Treatment Room, Periodontics',#690,$,$); +#705=IFCCLASSIFICATIONREFERENCE($,'13-51 64 39','Dental Treatment Room, Prosthodontics',#690,$,$); +#706=IFCCLASSIFICATIONREFERENCE($,'13-51 64 41','Dental X-Ray Room',#690,$,$); +#707=IFCCLASSIFICATIONREFERENCE($,'13-51 64 43','Instrument Preparation and Sterilization Room',#690,$,$); +#708=IFCCLASSIFICATIONREFERENCE($,'13-51 64 45','Maxillo-Facial Laboratory',#690,$,$); +#709=IFCCLASSIFICATIONREFERENCE($,'13-51 64 47','Maxillo-Facial Treatment Room',#690,$,$); +#710=IFCCLASSIFICATIONREFERENCE($,'13-51 64 49','Oral Pathology Laboratory',#690,$,$); +#711=IFCCLASSIFICATIONREFERENCE($,'13-51 64 51','Oral Surgery Residency Room',#690,$,$); +#712=IFCCLASSIFICATIONREFERENCE($,'13-51 64 53','Oral Surgery Room',#690,$,$); +#713=IFCCLASSIFICATIONREFERENCE($,'13-51 64 55','Panoramic Dental X-Ray Room',#690,$,$); +#714=IFCCLASSIFICATIONREFERENCE($,'13-51 64 57','Dental X-Ray Support Room',#690,$,$); +#715=IFCCLASSIFICATIONREFERENCE($,'13-51 67 00','Medical Research and Development Spaces',#315,$,$); +#716=IFCCLASSIFICATIONREFERENCE($,'13-51 67 11','Research Animal Recovery Area',#715,$,$); +#717=IFCCLASSIFICATIONREFERENCE($,'13-51 67 13','Barrier Suite, Procedure Laboratory',#715,$,$); +#718=IFCCLASSIFICATIONREFERENCE($,'13-51 67 15','Biomedical Research BSL3 Suite Tissue Culture Room',#715,$,$); +#719=IFCCLASSIFICATIONREFERENCE($,'13-51 67 17','Biomedical Research Tissue Culture Room',#715,$,$); +#720=IFCCLASSIFICATIONREFERENCE($,'13-51 67 18','Laboratory, Research, Biochemistry',#715,$,$); +#721=IFCCLASSIFICATIONREFERENCE($,'13-51 67 19','Biosafety Level 3 Laboratory',#715,$,$); +#722=IFCCLASSIFICATIONREFERENCE($,'13-51 67 21','BSL3 Infectious Disease Suite, Procedure Laboratory',#715,$,$); +#723=IFCCLASSIFICATIONREFERENCE($,'13-51 67 23','BSL3 Procedure Room',#715,$,$); +#724=IFCCLASSIFICATIONREFERENCE($,'13-51 67 25','Environmental Suite Infectious Disease Procedure Laboratory',#715,$,$); +#725=IFCCLASSIFICATIONREFERENCE($,'13-51 67 27','Research Infectious Disease Animal Holding Area',#715,$,$); +#726=IFCCLASSIFICATIONREFERENCE($,'13-51 67 29','Research Veterinary Radiography Control Room',#715,$,$); +#727=IFCCLASSIFICATIONREFERENCE($,'13-51 67 31','Research and Development Machine Shop',#715,$,$); +#728=IFCCLASSIFICATIONREFERENCE($,'13-51 67 33','Research Veterinary Radiography Procedure Room',#715,$,$); +#729=IFCCLASSIFICATIONREFERENCE($,'13-51 67 35','Research Diagnostic Laboratory',#715,$,$); +#730=IFCCLASSIFICATIONREFERENCE($,'13-51 67 37','Research NMR Room',#715,$,$); +#731=IFCCLASSIFICATIONREFERENCE($,'13-51 67 39','Research Procedure Laboratory',#715,$,$); +#732=IFCCLASSIFICATIONREFERENCE($,'13-51 67 41','Research Veterinary Surgical Suite, Animal Preparation Room',#715,$,$); +#733=IFCCLASSIFICATIONREFERENCE($,'13-51 67 43','Research Veterinary BSL3 Infectious Disease Suite Holding Room',#715,$,$); +#734=IFCCLASSIFICATIONREFERENCE($,'13-51 67 45','Research Veterinary Barrier Suite Holding Room',#715,$,$); +#735=IFCCLASSIFICATIONREFERENCE($,'13-51 67 47','Research Veterinary Chemical/Radioisotope Suite Holding Room',#715,$,$); +#736=IFCCLASSIFICATIONREFERENCE($,'13-51 67 49','Research Veterinary Environmental Suite Holding Room',#715,$,$); +#737=IFCCLASSIFICATIONREFERENCE($,'13-51 67 51','Research Veterinary Quarantine Holding Room',#715,$,$); +#738=IFCCLASSIFICATIONREFERENCE($,'13-51 67 53','Research Veterinary Surgery Room',#715,$,$); +#739=IFCCLASSIFICATIONREFERENCE($,'13-51 91 00','Veterinary Spaces',#315,$,$); +#740=IFCCLASSIFICATIONREFERENCE($,'13-51 91 11','Hospitalization Kennel',#739,$,$); +#741=IFCCLASSIFICATIONREFERENCE($,'13-51 91 14','Infectious Disease Animal Holding Area',#739,$,$); +#742=IFCCLASSIFICATIONREFERENCE($,'13-51 91 17','Veterinary Radiography Control Room',#739,$,$); +#743=IFCCLASSIFICATIONREFERENCE($,'13-51 91 20','Veterinary Radiography Procedure Room',#739,$,$); +#744=IFCCLASSIFICATIONREFERENCE($,'13-51 91 23','Veterinary Surgical Suite, Animal Preparation Room',#739,$,$); +#745=IFCCLASSIFICATIONREFERENCE($,'13-51 91 26','Veterinary BSL3 Infectious Disease Suite Holding Room',#739,$,$); +#746=IFCCLASSIFICATIONREFERENCE($,'13-51 91 29','Veterinary Barrier Suite Holding Room',#739,$,$); +#747=IFCCLASSIFICATIONREFERENCE($,'13-51 91 32','Veterinary Examination and Treatment Room',#739,$,$); +#748=IFCCLASSIFICATIONREFERENCE($,'13-51 91 35','Veterinary Quarantine Holding Room',#739,$,$); +#749=IFCCLASSIFICATIONREFERENCE($,'13-51 91 38','Veterinary Surgery Room',#739,$,$); +#750=IFCCLASSIFICATIONREFERENCE($,'13-51 91 41','Cage Wash Area',#739,$,$); +#751=IFCCLASSIFICATIONREFERENCE($,'13-51 91 44','Veterinary Food Preparation Room',#739,$,$); +#752=IFCCLASSIFICATIONREFERENCE($,'13-53 00 00','Laboratory Spaces',#4,$,$); +#753=IFCCLASSIFICATIONREFERENCE($,'13-53 11 00','Chemistry Laboratories',#752,$,$); +#754=IFCCLASSIFICATIONREFERENCE($,'13-53 13 00','Biosciences Laboratories',#752,$,$); +#755=IFCCLASSIFICATIONREFERENCE($,'13-53 15 00','Physical Sciences Laboratories',#752,$,$); +#756=IFCCLASSIFICATIONREFERENCE($,'13-53 15 11','Optical Physics Laboratory',#755,$,$); +#757=IFCCLASSIFICATIONREFERENCE($,'13-53 15 13','Physics Research Laboratory',#755,$,$); +#758=IFCCLASSIFICATIONREFERENCE($,'13-53 17 00','Astronomy Laboratories',#752,$,$); +#759=IFCCLASSIFICATIONREFERENCE($,'13-53 17 11','Astronomy Research Laboratory',#758,$,$); +#760=IFCCLASSIFICATIONREFERENCE($,'13-53 19 00','Earth and Environmental Sciences Laboratories',#752,$,$); +#761=IFCCLASSIFICATIONREFERENCE($,'13-53 19 11','Geology Laboratory',#760,$,$); +#762=IFCCLASSIFICATIONREFERENCE($,'13-53 19 13','Earth Sciences Research Laboratory',#760,$,$); +#763=IFCCLASSIFICATIONREFERENCE($,'13-53 21 00','Forensics Laboratories',#752,$,$); +#764=IFCCLASSIFICATIONREFERENCE($,'13-53 23 00','Psychology Laboratories',#752,$,$); +#765=IFCCLASSIFICATIONREFERENCE($,'13-53 25 00','Bench Laboratories',#752,$,$); +#766=IFCCLASSIFICATIONREFERENCE($,'13-53 27 00','Dry Laboratories',#752,$,$); +#767=IFCCLASSIFICATIONREFERENCE($,'13-53 29 00','Integration Laboratories',#752,$,$); +#768=IFCCLASSIFICATIONREFERENCE($,'13-53 31 00','Wet Laboratories',#752,$,$); +#769=IFCCLASSIFICATIONREFERENCE($,'13-53 33 00','Laboratory Storage Spaces',#752,$,$); +#770=IFCCLASSIFICATIONREFERENCE($,'13-53 35 00','Laboratory Support Spaces',#752,$,$); +#771=IFCCLASSIFICATIONREFERENCE($,'13-55 00 00','Commerce Activity Spaces',#4,$,$); +#772=IFCCLASSIFICATIONREFERENCE($,'13-55 11 00','Office Spaces',#771,$,$); +#773=IFCCLASSIFICATIONREFERENCE($,'13-55 11 11','Office Service',#772,$,$); +#774=IFCCLASSIFICATIONREFERENCE($,'13-55 11 13','Dedicated Enclosed Workstation',#772,$,$); +#775=IFCCLASSIFICATIONREFERENCE($,'13-55 11 15','Shared Enclosed Workstation',#772,$,$); +#776=IFCCLASSIFICATIONREFERENCE($,'13-55 11 17','Dedicated Open Workstation',#772,$,$); +#777=IFCCLASSIFICATIONREFERENCE($,'13-55 11 19','Shared Open Workstation',#772,$,$); +#778=IFCCLASSIFICATIONREFERENCE($,'13-55 11 21','Open Team Setting',#772,$,$); +#779=IFCCLASSIFICATIONREFERENCE($,'13-55 11 23','General File and Storage',#772,$,$); +#780=IFCCLASSIFICATIONREFERENCE($,'13-55 11 25','Shared Workstation File and Storage',#772,$,$); +#781=IFCCLASSIFICATIONREFERENCE($,'13-55 11 27','Shared Equipment Station',#772,$,$); +#782=IFCCLASSIFICATIONREFERENCE($,'13-55 11 29','Lookout Gallery',#772,$,$); +#783=IFCCLASSIFICATIONREFERENCE($,'13-55 13 00','Banking Spaces',#771,$,$); +#784=IFCCLASSIFICATIONREFERENCE($,'13-55 13 11','Bank Teller Space',#783,$,$); +#785=IFCCLASSIFICATIONREFERENCE($,'13-55 13 13','Automatic Teller Machine Space',#783,$,$); +#786=IFCCLASSIFICATIONREFERENCE($,'13-55 13 15','Vault',#783,$,$); +#787=IFCCLASSIFICATIONREFERENCE($,'13-55 15 00','Trading Spaces',#771,$,$); +#788=IFCCLASSIFICATIONREFERENCE($,'13-55 15 11','Trading Floor',#787,$,$); +#789=IFCCLASSIFICATIONREFERENCE($,'13-55 17 00','Demonstration Spaces',#771,$,$); +#790=IFCCLASSIFICATIONREFERENCE($,'13-55 19 00','Sales Spaces',#771,$,$); +#791=IFCCLASSIFICATIONREFERENCE($,'13-55 19 11','Checkout Space',#790,$,$); +#792=IFCCLASSIFICATIONREFERENCE($,'13-55 19 13','Display Space',#790,$,$); +#793=IFCCLASSIFICATIONREFERENCE($,'13-55 19 15','Fitting Space',#790,$,$); +#794=IFCCLASSIFICATIONREFERENCE($,'13-55 19 17','Vending Machine Area',#790,$,$); +#795=IFCCLASSIFICATIONREFERENCE($,'13-55 19 19','Auction Room',#790,$,$); +#796=IFCCLASSIFICATIONREFERENCE($,'13-55 19 21','Pet Shop Animal Space',#790,$,$); +#797=IFCCLASSIFICATIONREFERENCE($,'13-55 21 00','Commercial Service and Repair Spaces',#771,$,$); +#798=IFCCLASSIFICATIONREFERENCE($,'13-55 23 00','Commercial Support Spaces',#771,$,$); +#799=IFCCLASSIFICATIONREFERENCE($,'13-55 27 00','Hotel, Motel, Hostel, and Dormitory Service Spaces',#771,$,$); +#800=IFCCLASSIFICATIONREFERENCE($,'13-55 27 11','Dormitory',#799,$,$); +#801=IFCCLASSIFICATIONREFERENCE($,'13-55 27 13','Hotel Residence Room',#799,$,$); +#802=IFCCLASSIFICATIONREFERENCE($,'13-55 29 00','Commerce Activity Support Areas',#771,$,$); +#803=IFCCLASSIFICATIONREFERENCE($,'13-55 29 11','Information Counter',#802,$,$); +#804=IFCCLASSIFICATIONREFERENCE($,'13-55 29 13','Lobby Non-Circulation Space',#802,$,$); +#805=IFCCLASSIFICATIONREFERENCE($,'13-55 29 15','Post Office Space',#802,$,$); +#806=IFCCLASSIFICATIONREFERENCE($,'13-55 29 17','Mail Room Space',#802,$,$); +#807=IFCCLASSIFICATIONREFERENCE($,'13-55 29 19','Box Lobby',#802,$,$); +#808=IFCCLASSIFICATIONREFERENCE($,'13-55 29 21','Meeting Spaces',#802,$,$); +#809=IFCCLASSIFICATIONREFERENCE($,'13-55 29 21 11','Conference Room',#808,$,$); +#810=IFCCLASSIFICATIONREFERENCE($,'13-55 29 21 13','Press Conference Room',#808,$,$); +#811=IFCCLASSIFICATIONREFERENCE($,'13-55 29 21 15','Community Room',#808,$,$); +#812=IFCCLASSIFICATIONREFERENCE($,'13-55 29 21 17','War Room',#808,$,$); +#813=IFCCLASSIFICATIONREFERENCE($,'13-55 29 21 19','Meeting Equipment Room',#808,$,$); +#814=IFCCLASSIFICATIONREFERENCE($,'13-55 29 23','Waiting Space',#802,$,$); +#815=IFCCLASSIFICATIONREFERENCE($,'13-55 29 23 11','Reception Space',#814,$,$); +#816=IFCCLASSIFICATIONREFERENCE($,'13-55 29 23 13','Waiting Room',#814,$,$); +#817=IFCCLASSIFICATIONREFERENCE($,'13-55 29 23 15','Queuing Space',#814,$,$); +#818=IFCCLASSIFICATIONREFERENCE($,'13-55 29 25','Business Support Space',#802,$,$); +#819=IFCCLASSIFICATIONREFERENCE($,'13-57 00 00','Service Activity Spaces',#4,$,$); +#820=IFCCLASSIFICATIONREFERENCE($,'13-57 11 00','Grooming Activity Spaces',#819,$,$); +#821=IFCCLASSIFICATIONREFERENCE($,'13-57 11 11','Makeup Space',#820,$,$); +#822=IFCCLASSIFICATIONREFERENCE($,'13-57 11 13','Haircutting Space',#820,$,$); +#823=IFCCLASSIFICATIONREFERENCE($,'13-57 13 00','Food Service',#819,$,$); +#824=IFCCLASSIFICATIONREFERENCE($,'13-57 13 11','Cooking Spaces',#823,$,$); +#825=IFCCLASSIFICATIONREFERENCE($,'13-57 13 13','Kitchen Space',#823,$,$); +#826=IFCCLASSIFICATIONREFERENCE($,'13-57 13 13 11','Food Preparation Space',#825,$,$); +#827=IFCCLASSIFICATIONREFERENCE($,'13-57 13 13 13','Cooking Space',#825,$,$); +#828=IFCCLASSIFICATIONREFERENCE($,'13-57 13 13 15','Dishwashing Station',#825,$,$); +#829=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15','Dining and Drinking Spaces',#823,$,$); +#830=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15 11','Dining Room',#829,$,$); +#831=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15 13','Banquet Hall',#829,$,$); +#832=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15 15','Food Court',#829,$,$); +#833=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15 17','Snack Bar',#829,$,$); +#834=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15 19','Salad Bar',#829,$,$); +#835=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15 21','Liquor Bar',#829,$,$); +#836=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15 23','Beverage Station',#829,$,$); +#837=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15 25','Table Bussing Station',#829,$,$); +#838=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15 27','Serving Station',#829,$,$); +#839=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15 29','Vending Perishable Product Space',#829,$,$); +#840=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15 31','Cafeteria Vending Space',#829,$,$); +#841=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15 33','Tray Return Space',#829,$,$); +#842=IFCCLASSIFICATIONREFERENCE($,'13-57 13 15 35','Food Discard Station',#829,$,$); +#843=IFCCLASSIFICATIONREFERENCE($,'13-57 13 17','Coffee stations',#823,$,$); +#844=IFCCLASSIFICATIONREFERENCE($,'13-57 15 00','Child Care Spaces',#819,$,$); +#845=IFCCLASSIFICATIONREFERENCE($,'13-57 15 11','Daycare sickroom',#844,$,$); +#846=IFCCLASSIFICATIONREFERENCE($,'13-57 15 13','Child Day Care Space',#844,$,$); +#847=IFCCLASSIFICATIONREFERENCE($,'13-57 15 15','Play Room',#844,$,$); +#848=IFCCLASSIFICATIONREFERENCE($,'13-57 15 17','CLD\X2\2013\X0\Child Care',#844,$,$); +#849=IFCCLASSIFICATIONREFERENCE($,'13-57 17 00','Resting Spaces',#819,$,$); +#850=IFCCLASSIFICATIONREFERENCE($,'13-57 17 11','Rest Area',#849,$,$); +#851=IFCCLASSIFICATIONREFERENCE($,'13-57 17 13','Break Room',#849,$,$); +#852=IFCCLASSIFICATIONREFERENCE($,'13-57 21 00','Laundry/Dry Cleaning Space',#819,$,$); +#853=IFCCLASSIFICATIONREFERENCE($,'13-57 23 00','Smoking Space',#819,$,$); +#854=IFCCLASSIFICATIONREFERENCE($,'13-59 00 00','Production, Fabrication, and Maintenance Spaces',#4,$,$); +#855=IFCCLASSIFICATIONREFERENCE($,'13-59 11 00','Material Handling Area',#854,$,$); +#856=IFCCLASSIFICATIONREFERENCE($,'13-59 13 00','Batching Space',#854,$,$); +#857=IFCCLASSIFICATIONREFERENCE($,'13-59 15 00','Production Process',#854,$,$); +#858=IFCCLASSIFICATIONREFERENCE($,'13-59 15 11','Workbench',#857,$,$); +#859=IFCCLASSIFICATIONREFERENCE($,'13-59 15 13','Mock-up Space',#857,$,$); +#860=IFCCLASSIFICATIONREFERENCE($,'13-59 17 00','Printing and Reproduction Spaces',#854,$,$); +#861=IFCCLASSIFICATIONREFERENCE($,'13-59 19 00','Quality Control and Test Spaces',#854,$,$); +#862=IFCCLASSIFICATIONREFERENCE($,'13-59 19 11','Product Inspection Space',#861,$,$); +#863=IFCCLASSIFICATIONREFERENCE($,'13-59 19 13','Production Observation Space',#861,$,$); +#864=IFCCLASSIFICATIONREFERENCE($,'13-59 21 00','Production Service and Repair Spaces',#854,$,$); +#865=IFCCLASSIFICATIONREFERENCE($,'13-59 23 00','Production and In-Process Storage Spaces',#854,$,$); +#866=IFCCLASSIFICATIONREFERENCE($,'13-59 25 00','Production Support Spaces',#854,$,$); +#867=IFCCLASSIFICATIONREFERENCE($,'13-59 29 00','Greenhouse Spaces',#854,$,$); +#868=IFCCLASSIFICATIONREFERENCE($,'13-59 29 11','Greenhouse Support Space',#867,$,$); +#869=IFCCLASSIFICATIONREFERENCE($,'13-61 00 00','Protective Spaces',#4,$,$); +#870=IFCCLASSIFICATIONREFERENCE($,'13-61 11 00','Animal Securing Spaces',#869,$,$); +#871=IFCCLASSIFICATIONREFERENCE($,'13-61 11 11','Cage',#870,$,$); +#872=IFCCLASSIFICATIONREFERENCE($,'13-61 11 13','Animal Stall',#870,$,$); +#873=IFCCLASSIFICATIONREFERENCE($,'13-61 11 15','Kennel',#870,$,$); +#874=IFCCLASSIFICATIONREFERENCE($,'13-61 11 17','Aquarium',#870,$,$); +#875=IFCCLASSIFICATIONREFERENCE($,'13-61 13 00','Detention Spaces',#869,$,$); +#876=IFCCLASSIFICATIONREFERENCE($,'13-61 13 11','Detention Cell',#875,$,$); +#877=IFCCLASSIFICATIONREFERENCE($,'13-61 13 13','Holding Cell',#875,$,$); +#878=IFCCLASSIFICATIONREFERENCE($,'13-61 13 15','Impound Lot',#875,$,$); +#879=IFCCLASSIFICATIONREFERENCE($,'13-61 13 17','Dayroom',#875,$,$); +#880=IFCCLASSIFICATIONREFERENCE($,'13-61 15 00','Spaces for Protection from the Elements',#869,$,$); +#881=IFCCLASSIFICATIONREFERENCE($,'13-61 15 11','Park Shelter',#880,$,$); +#882=IFCCLASSIFICATIONREFERENCE($,'13-61 15 13','Entry Porch',#880,$,$); +#883=IFCCLASSIFICATIONREFERENCE($,'13-61 15 15','Covered Walkway',#880,$,$); +#884=IFCCLASSIFICATIONREFERENCE($,'13-61 15 17','Canopy',#880,$,$); +#885=IFCCLASSIFICATIONREFERENCE($,'13-61 15 19','Shielded Room',#880,$,$); +#886=IFCCLASSIFICATIONREFERENCE($,'13-61 15 21','Containment Room',#880,$,$); +#887=IFCCLASSIFICATIONREFERENCE($,'13-61 17 00','Spaces for Protection from Violence',#869,$,$); +#888=IFCCLASSIFICATIONREFERENCE($,'13-61 17 11','Safe Room',#887,$,$); +#889=IFCCLASSIFICATIONREFERENCE($,'13-61 17 13','Bunker',#887,$,$); +#890=IFCCLASSIFICATIONREFERENCE($,'13-61 17 15','Bomb Shelter',#887,$,$); +#891=IFCCLASSIFICATIONREFERENCE($,'13-63 00 00','Storage Spaces',#4,$,$); +#892=IFCCLASSIFICATIONREFERENCE($,'13-63 11 00','Warehouse Spaces',#891,$,$); +#893=IFCCLASSIFICATIONREFERENCE($,'13-63 11 11','High Bay Warehouse Space',#892,$,$); +#894=IFCCLASSIFICATIONREFERENCE($,'13-63 11 13','General Warehouse Space',#892,$,$); +#895=IFCCLASSIFICATIONREFERENCE($,'13-63 11 15','Warehouse Support Space',#892,$,$); +#896=IFCCLASSIFICATIONREFERENCE($,'13-63 13 00','Non-Warehouse Storage Spaces',#891,$,$); +#897=IFCCLASSIFICATIONREFERENCE($,'13-63 13 11','Storage Room',#896,$,$); +#898=IFCCLASSIFICATIONREFERENCE($,'13-63 13 11 11','GNS\X2\2013\X0\General Storage',#897,$,$); +#899=IFCCLASSIFICATIONREFERENCE($,'13-63 13 13','Closet',#896,$,$); +#900=IFCCLASSIFICATIONREFERENCE($,'13-63 13 15','Coat Check',#896,$,$); +#901=IFCCLASSIFICATIONREFERENCE($,'13-63 13 17','Locker Room',#896,$,$); +#902=IFCCLASSIFICATIONREFERENCE($,'13-63 13 19','Filing Space',#896,$,$); +#903=IFCCLASSIFICATIONREFERENCE($,'13-63 13 21','Supply Room',#896,$,$); +#904=IFCCLASSIFICATIONREFERENCE($,'13-63 13 23','Unit Storage',#896,$,$); +#905=IFCCLASSIFICATIONREFERENCE($,'13-63 13 25','Consolidation/Containerization Point',#896,$,$); +#906=IFCCLASSIFICATIONREFERENCE($,'13-63 13 27','Self Storage Space',#896,$,$); +#907=IFCCLASSIFICATIONREFERENCE($,'13-63 13 29','Operational Storage (Misc)',#896,$,$); +#908=IFCCLASSIFICATIONREFERENCE($,'13-63 13 31','Operational Hazardous/Flammable Storage',#896,$,$); +#909=IFCCLASSIFICATIONREFERENCE($,'13-63 15 00','Moveable Storage Spaces',#891,$,$); +#910=IFCCLASSIFICATIONREFERENCE($,'13-63 15 11','Vehicle Storage Compartment',#909,$,$); +#911=IFCCLASSIFICATIONREFERENCE($,'13-63 15 13','Portable Bin',#909,$,$); +#912=IFCCLASSIFICATIONREFERENCE($,'13-63 15 15','Vessel Hold',#909,$,$); +#913=IFCCLASSIFICATIONREFERENCE($,'13-63 17 00','Environmentally Controlled Storage Spaces',#891,$,$); +#914=IFCCLASSIFICATIONREFERENCE($,'13-63 17 11','Refrigeration Compartment',#913,$,$); +#915=IFCCLASSIFICATIONREFERENCE($,'13-63 17 13','Freezing Compartment',#913,$,$); +#916=IFCCLASSIFICATIONREFERENCE($,'13-63 17 15','Humidity Controlled Storage Space',#913,$,$); +#917=IFCCLASSIFICATIONREFERENCE($,'13-63 17 17','Vacuum Sealed Storage Compartment',#913,$,$); +#918=IFCCLASSIFICATIONREFERENCE($,'13-63 19 00','Specialty Storage Spaces',#891,$,$); +#919=IFCCLASSIFICATIONREFERENCE($,'13-63 19 11','Sanitary Storage Room',#918,$,$); +#920=IFCCLASSIFICATIONREFERENCE($,'13-63 19 13','Soiled Storage Room Space',#918,$,$); +#921=IFCCLASSIFICATIONREFERENCE($,'13-63 19 15','Sacristy',#918,$,$); +#922=IFCCLASSIFICATIONREFERENCE($,'13-63 19 17','Vestry',#918,$,$); +#923=IFCCLASSIFICATIONREFERENCE($,'13-63 19 19','Hazardous Material Storage Space',#918,$,$); +#924=IFCCLASSIFICATIONREFERENCE($,'13-63 19 21','Book Stacks',#918,$,$); +#925=IFCCLASSIFICATIONREFERENCE($,'13-63 19 23','Baggage Claim',#918,$,$); +#926=IFCCLASSIFICATIONREFERENCE($,'13-63 19 25','Evidence Room',#918,$,$); +#927=IFCCLASSIFICATIONREFERENCE($,'13-63 19 27','Vehicle Impound Lot',#918,$,$); +#928=IFCCLASSIFICATIONREFERENCE($,'13-63 19 29','Operating Fuel Storage',#918,$,$); +#929=IFCCLASSIFICATIONREFERENCE($,'13-65 00 00','Private Residential Spaces',#4,$,$); +#930=IFCCLASSIFICATIONREFERENCE($,'13-65 11 00','On-call Room',#929,$,$); +#931=IFCCLASSIFICATIONREFERENCE($,'13-65 13 00','Bathroom',#929,$,$); +#932=IFCCLASSIFICATIONREFERENCE($,'13-65 13 11','Shower Space',#931,$,$); +#933=IFCCLASSIFICATIONREFERENCE($,'13-65 13 13','Toilet Space',#931,$,$); +#934=IFCCLASSIFICATIONREFERENCE($,'13-65 13 15','Ablution Room',#931,$,$); +#935=IFCCLASSIFICATIONREFERENCE($,'13-65 13 17','Combination Toilet and Bathing Space',#931,$,$); +#936=IFCCLASSIFICATIONREFERENCE($,'13-65 15 00','Mud Room',#929,$,$); +#937=IFCCLASSIFICATIONREFERENCE($,'13-65 17 00','Laundry Room',#929,$,$); +#938=IFCCLASSIFICATIONREFERENCE($,'13-65 19 00','Bedroom',#929,$,$); +#939=IFCCLASSIFICATIONREFERENCE($,'13-65 19 11','Mental Health Resident Bedroom',#938,$,$); +#940=IFCCLASSIFICATIONREFERENCE($,'13-65 19 13','Mental Health Resident Bedroom, Bariatric',#938,$,$); +#941=IFCCLASSIFICATIONREFERENCE($,'13-65 21 00','Nursery',#929,$,$); +#942=IFCCLASSIFICATIONREFERENCE($,'13-65 23 00','Kitchen',#929,$,$); +#943=IFCCLASSIFICATIONREFERENCE($,'13-67 00 00','Alternate Workplace',#4,$,$); +#944=IFCCLASSIFICATIONREFERENCE($,'13-67 11 00','Customer Site',#943,$,$); +#945=IFCCLASSIFICATIONREFERENCE($,'13-67 13 00','Home Office',#943,$,$); +#946=IFCCLASSIFICATIONREFERENCE($,'13-67 15 00','Rent-An-Office',#943,$,$); +#947=IFCCLASSIFICATIONREFERENCE($,'13-67 17 00','No Fixed Location',#943,$,$); +#948=IFCCLASSIFICATIONREFERENCE($,'13-67 19 00','Supplier Site',#943,$,$); +#949=IFCCLASSIFICATIONREFERENCE($,'13-69 00 00','Building Associated Spaces',#4,$,$); +#950=IFCCLASSIFICATIONREFERENCE($,'13-69 11 00','Roof',#949,$,$); +#951=IFCCLASSIFICATIONREFERENCE($,'13-69 13 00','Roof Terrace',#949,$,$); +#952=IFCCLASSIFICATIONREFERENCE($,'13-69 15 00','Penthouse',#949,$,$); +#953=IFCCLASSIFICATIONREFERENCE($,'13-69 17 00','Antenna Farm',#949,$,$); +#954=IFCCLASSIFICATIONREFERENCE($,'13-69 19 00','Heliport',#949,$,$); +#955=IFCCLASSIFICATIONREFERENCE($,'13-69 21 00','Balcony',#949,$,$); +#956=IFCCLASSIFICATIONREFERENCE($,'13-69 23 00','Deck',#949,$,$); +#957=IFCCLASSIFICATIONREFERENCE($,'13-69 25 00','Pedestrian Travel Spaces',#949,$,$); +#958=IFCCLASSIFICATIONREFERENCE($,'13-69 25 11','Sidewalk',#957,$,$); +#959=IFCCLASSIFICATIONREFERENCE($,'13-69 25 13','Pedestrian Way',#957,$,$); +#960=IFCCLASSIFICATIONREFERENCE($,'13-69 25 15','Pedestrian Bridge',#957,$,$); +#961=IFCCLASSIFICATIONREFERENCE($,'13-69 25 17','Footpath',#957,$,$); +#962=IFCCLASSIFICATIONREFERENCE($,'13-69 25 19','Trail',#957,$,$); +#963=IFCCLASSIFICATIONREFERENCE($,'13-69 25 21','Gangway',#957,$,$); +#964=IFCCLASSIFICATIONREFERENCE($,'Table 21 - Elements',$,#2,'Assigns category classification to building elements based on this OmniClass (edition 2012) specification.\X2\000A000A\X0\For example: use this rule to comply with\X2\000A\X0\- ''Concept Design BIM 2010'' MVD (GSA), which requires such classification for IfcElement, IfcTypeProduct (except IfcSpaceType) and IfcSystem entities.\X2\000A\X0\- ''FM Handover'' MVD (COBie), which requires such classification for IfcTypeProduct (except IfcSpaceType), IfcGroup and IfcSystem entities.\X2\000A000A\X0\''Apply'' creates a Classification Reference for selected IFC entity, using OmniClass-required attributes derived from the item that you choose in the following list.\X2\000A00090009\X0\',$); +#965=IFCCLASSIFICATIONREFERENCE($,'21-01 00 00','Substructure',#964,$,$); +#966=IFCCLASSIFICATIONREFERENCE($,'21-01 10','Foundations',#965,$,$); +#967=IFCCLASSIFICATIONREFERENCE($,'21-01 10 10','Standard Foundations',#966,$,$); +#968=IFCCLASSIFICATIONREFERENCE($,'21-01 10 10 10','Wall Foundations',#967,$,$); +#969=IFCCLASSIFICATIONREFERENCE($,'21-01 10 10 30','Column Foundations',#967,$,$); +#970=IFCCLASSIFICATIONREFERENCE($,'21-01 10 10 90','Standard Foundation Supplementary Components',#967,$,$); +#971=IFCCLASSIFICATIONREFERENCE($,'21-01 10 20','Special Foundations',#966,$,$); +#972=IFCCLASSIFICATIONREFERENCE($,'21-01 10 20 10','Driven Piles',#971,$,$); +#973=IFCCLASSIFICATIONREFERENCE($,'21-01 10 20 15','Bored Piles',#971,$,$); +#974=IFCCLASSIFICATIONREFERENCE($,'21-01 10 20 20','Caissons',#971,$,$); +#975=IFCCLASSIFICATIONREFERENCE($,'21-01 10 20 30','Special Foundation Walls',#971,$,$); +#976=IFCCLASSIFICATIONREFERENCE($,'21-01 10 20 40','Foundation Anchors',#971,$,$); +#977=IFCCLASSIFICATIONREFERENCE($,'21-01 10 20 50','Underpinning',#971,$,$); +#978=IFCCLASSIFICATIONREFERENCE($,'21-01 10 20 60','Raft Foundations',#971,$,$); +#979=IFCCLASSIFICATIONREFERENCE($,'21-01 10 20 70','Pile Caps',#971,$,$); +#980=IFCCLASSIFICATIONREFERENCE($,'21-01 10 20 80','Grade Beams',#971,$,$); +#981=IFCCLASSIFICATIONREFERENCE($,'21-01 20','Subgrade Enclosures',#965,$,$); +#982=IFCCLASSIFICATIONREFERENCE($,'21-01 20 10','Walls for Subgrade Enclosures',#981,$,$); +#983=IFCCLASSIFICATIONREFERENCE($,'21-01 20 10 10','Subgrade Enclosure Wall Construction',#982,$,$); +#984=IFCCLASSIFICATIONREFERENCE($,'21-01 20 10 20','Subgrade Enclosure Wall Interior Skin',#982,$,$); +#985=IFCCLASSIFICATIONREFERENCE($,'21-01 20 10 90','Subgrade Enclosure Wall Supplementary Components',#982,$,$); +#986=IFCCLASSIFICATIONREFERENCE($,'21-01 40','Slabs-On-Grade',#965,$,$); +#987=IFCCLASSIFICATIONREFERENCE($,'21-01 40 10','Standard Slabs-on-Grade',#986,$,$); +#988=IFCCLASSIFICATIONREFERENCE($,'21-01 40 20','Structural Slabs-on-Grade',#986,$,$); +#989=IFCCLASSIFICATIONREFERENCE($,'21-01 40 30','Slab Trenches',#986,$,$); +#990=IFCCLASSIFICATIONREFERENCE($,'21-01 40 40','Pits and Bases',#986,$,$); +#991=IFCCLASSIFICATIONREFERENCE($,'21-01 40 90','Slab-On-Grade Supplementary Components',#986,$,$); +#992=IFCCLASSIFICATIONREFERENCE($,'21-01 40 90 10','Perimeter Insulation',#991,$,$); +#993=IFCCLASSIFICATIONREFERENCE($,'21-01 40 90 20','Vapor Retarder',#991,$,$); +#994=IFCCLASSIFICATIONREFERENCE($,'21-01 40 90 30','Waterproofing',#991,$,$); +#995=IFCCLASSIFICATIONREFERENCE($,'21-01 40 90 50','Mud Slab',#991,$,$); +#996=IFCCLASSIFICATIONREFERENCE($,'21-01 40 90 60','Subbase Layer',#991,$,$); +#997=IFCCLASSIFICATIONREFERENCE($,'21-01 60','Water and Gas Mitigation',#965,$,$); +#998=IFCCLASSIFICATIONREFERENCE($,'21-01 60 10','Building Subdrainage',#997,$,$); +#999=IFCCLASSIFICATIONREFERENCE($,'21-01 60 10 10','Foundation Drainage',#998,$,$); +#1000=IFCCLASSIFICATIONREFERENCE($,'21-01 60 10 20','Underslab Drainage',#998,$,$); +#1001=IFCCLASSIFICATIONREFERENCE($,'21-01 60 20','Off-Gassing Mitigation',#997,$,$); +#1002=IFCCLASSIFICATIONREFERENCE($,'21-01 60 20 10','Radon Mitigation',#1001,$,$); +#1003=IFCCLASSIFICATIONREFERENCE($,'21-01 60 20 50','Methane Mitigation',#1001,$,$); +#1004=IFCCLASSIFICATIONREFERENCE($,'21-01 90','Substructure Related Activities',#965,$,$); +#1005=IFCCLASSIFICATIONREFERENCE($,'21-01 90 10','Substructure Excavation',#1004,$,$); +#1006=IFCCLASSIFICATIONREFERENCE($,'21-01 90 10 10','Backfill and Compaction',#1005,$,$); +#1007=IFCCLASSIFICATIONREFERENCE($,'21-01 90 20','Construction Dewatering',#1004,$,$); +#1008=IFCCLASSIFICATIONREFERENCE($,'21-01 90 30','Excavation Support',#1004,$,$); +#1009=IFCCLASSIFICATIONREFERENCE($,'21-01 90 30 10','Anchor Tiebacks',#1008,$,$); +#1010=IFCCLASSIFICATIONREFERENCE($,'21-01 90 30 20','Cofferdams',#1008,$,$); +#1011=IFCCLASSIFICATIONREFERENCE($,'21-01 90 30 40','Cribbing and Walers',#1008,$,$); +#1012=IFCCLASSIFICATIONREFERENCE($,'21-01 90 30 60','Ground Freezing',#1008,$,$); +#1013=IFCCLASSIFICATIONREFERENCE($,'21-01 90 30 70','Slurry Walls',#1008,$,$); +#1014=IFCCLASSIFICATIONREFERENCE($,'21-01 90 40','Soil Treatment',#1004,$,$); +#1015=IFCCLASSIFICATIONREFERENCE($,'21-02 00 00','Shell',#964,$,$); +#1016=IFCCLASSIFICATIONREFERENCE($,'21-02 10','Superstructure',#1015,$,$); +#1017=IFCCLASSIFICATIONREFERENCE($,'21-02 10 10','Floor Construction',#1016,$,$); +#1018=IFCCLASSIFICATIONREFERENCE($,'21-02 10 10 10','Floor Structural Frame',#1017,$,$); +#1019=IFCCLASSIFICATIONREFERENCE($,'21-02 10 10 20','Floor Decks, Slabs, and Toppings',#1017,$,$); +#1020=IFCCLASSIFICATIONREFERENCE($,'21-02 10 10 30','Balcony Floor Construction',#1017,$,$); +#1021=IFCCLASSIFICATIONREFERENCE($,'21-02 10 10 40','Mezzanine Floor Construction',#1017,$,$); +#1022=IFCCLASSIFICATIONREFERENCE($,'21-02 10 10 50','Ramps',#1017,$,$); +#1023=IFCCLASSIFICATIONREFERENCE($,'21-02 10 10 90','Floor Construction Supplementary Components',#1017,$,$); +#1024=IFCCLASSIFICATIONREFERENCE($,'21-02 10 20','Roof Construction',#1016,$,$); +#1025=IFCCLASSIFICATIONREFERENCE($,'21-02 10 20 10','Roof Structural Frame',#1024,$,$); +#1026=IFCCLASSIFICATIONREFERENCE($,'21-02 10 20 20','Roof Decks, Slabs, and Sheathing',#1024,$,$); +#1027=IFCCLASSIFICATIONREFERENCE($,'21-02 10 20 30','Canopy Construction',#1024,$,$); +#1028=IFCCLASSIFICATIONREFERENCE($,'21-02 10 20 90','Roof Construction Supplementary Components',#1024,$,$); +#1029=IFCCLASSIFICATIONREFERENCE($,'21-02 10 80','Stairs',#1016,$,$); +#1030=IFCCLASSIFICATIONREFERENCE($,'21-02 10 80 10','Stair Construction',#1029,$,$); +#1031=IFCCLASSIFICATIONREFERENCE($,'21-02 10 80 30','Stair Soffits',#1029,$,$); +#1032=IFCCLASSIFICATIONREFERENCE($,'21-02 10 80 50','Stair Railings',#1029,$,$); +#1033=IFCCLASSIFICATIONREFERENCE($,'21-02 10 80 60','Fire Escapes',#1029,$,$); +#1034=IFCCLASSIFICATIONREFERENCE($,'21-02 10 80 70','Metal Walkways',#1029,$,$); +#1035=IFCCLASSIFICATIONREFERENCE($,'21-02 10 80 80','Ladders',#1029,$,$); +#1036=IFCCLASSIFICATIONREFERENCE($,'21-02 20','Exterior Vertical Enclosures',#1015,$,$); +#1037=IFCCLASSIFICATIONREFERENCE($,'21-02 20 10','Exterior Walls',#1036,$,$); +#1038=IFCCLASSIFICATIONREFERENCE($,'21-02 20 10 10','Exterior Wall Veneer',#1037,$,$); +#1039=IFCCLASSIFICATIONREFERENCE($,'21-02 20 10 20','Exterior Wall Construction',#1037,$,$); +#1040=IFCCLASSIFICATIONREFERENCE($,'21-02 20 10 30','Exterior Wall Interior Skin',#1037,$,$); +#1041=IFCCLASSIFICATIONREFERENCE($,'21-02 20 10 40','Fabricated Exterior Wall Assemblies',#1037,$,$); +#1042=IFCCLASSIFICATIONREFERENCE($,'21-02 20 10 50','Parapets',#1037,$,$); +#1043=IFCCLASSIFICATIONREFERENCE($,'21-02 20 10 60','Equipment Screens',#1037,$,$); +#1044=IFCCLASSIFICATIONREFERENCE($,'21-02 20 10 80','Exterior Wall Supplementary Components',#1037,$,$); +#1045=IFCCLASSIFICATIONREFERENCE($,'21-02 20 10 90','Exterior Wall Opening Supplementary Components',#1037,$,$); +#1046=IFCCLASSIFICATIONREFERENCE($,'21-02 20 20','Exterior Windows',#1036,$,$); +#1047=IFCCLASSIFICATIONREFERENCE($,'21-02 20 20 10','Exterior Operating Windows',#1046,$,$); +#1048=IFCCLASSIFICATIONREFERENCE($,'21-02 20 20 20','Exterior Fixed Windows',#1046,$,$); +#1049=IFCCLASSIFICATIONREFERENCE($,'21-02 20 20 30','Exterior Window Wall',#1046,$,$); +#1050=IFCCLASSIFICATIONREFERENCE($,'21-02 20 20 50','Exterior Special Function Windows',#1046,$,$); +#1051=IFCCLASSIFICATIONREFERENCE($,'21-02 20 50','Exterior Doors and Grilles',#1036,$,$); +#1052=IFCCLASSIFICATIONREFERENCE($,'21-02 20 50 10','Exterior Entrance Doors',#1051,$,$); +#1053=IFCCLASSIFICATIONREFERENCE($,'21-02 20 50 20','Exterior Utility Doors',#1051,$,$); +#1054=IFCCLASSIFICATIONREFERENCE($,'21-02 20 50 30','Exterior Oversize Doors',#1051,$,$); +#1055=IFCCLASSIFICATIONREFERENCE($,'21-02 20 50 40','Exterior Special Function Doors',#1051,$,$); +#1056=IFCCLASSIFICATIONREFERENCE($,'21-02 20 50 60','Exterior Grilles',#1051,$,$); +#1057=IFCCLASSIFICATIONREFERENCE($,'21-02 20 50 70','Exterior Gates',#1051,$,$); +#1058=IFCCLASSIFICATIONREFERENCE($,'21-02 20 50 90','Exterior Door Supplementary Components',#1051,$,$); +#1059=IFCCLASSIFICATIONREFERENCE($,'21-02 20 70','Exterior Louvers and Vents',#1036,$,$); +#1060=IFCCLASSIFICATIONREFERENCE($,'21-02 20 70 10','Exterior Louvers',#1059,$,$); +#1061=IFCCLASSIFICATIONREFERENCE($,'21-02 20 70 50','Exterior Vents',#1059,$,$); +#1062=IFCCLASSIFICATIONREFERENCE($,'21-02 20 80','Exterior Wall Appurtenances',#1036,$,$); +#1063=IFCCLASSIFICATIONREFERENCE($,'21-02 20 80 10','Exterior Fixed Grilles and Screens',#1062,$,$); +#1064=IFCCLASSIFICATIONREFERENCE($,'21-02 20 80 30','Exterior Opening Protection Devices',#1062,$,$); +#1065=IFCCLASSIFICATIONREFERENCE($,'21-02 20 80 50','Exterior Balcony Walls and Railings',#1062,$,$); +#1066=IFCCLASSIFICATIONREFERENCE($,'21-02 20 80 70','Exterior Fabrications',#1062,$,$); +#1067=IFCCLASSIFICATIONREFERENCE($,'21-02 20 80 80','Bird Control Devices',#1062,$,$); +#1068=IFCCLASSIFICATIONREFERENCE($,'21-02 20 90','Exterior Wall Specialties',#1036,$,$); +#1069=IFCCLASSIFICATIONREFERENCE($,'21-02 30','Exterior Horizontal Enclosures',#1015,$,$); +#1070=IFCCLASSIFICATIONREFERENCE($,'21-02 30 10','Roofing',#1069,$,$); +#1071=IFCCLASSIFICATIONREFERENCE($,'21-02 30 10 10','Steep Slope Roofing',#1070,$,$); +#1072=IFCCLASSIFICATIONREFERENCE($,'21-02 30 10 50','Low-Slope Roofing',#1070,$,$); +#1073=IFCCLASSIFICATIONREFERENCE($,'21-02 30 10 70','Canopy Roofing',#1070,$,$); +#1074=IFCCLASSIFICATIONREFERENCE($,'21-02 30 10 90','Roofing Supplementary Components',#1070,$,$); +#1075=IFCCLASSIFICATIONREFERENCE($,'21-02 30 20','Roof Appurtenances',#1069,$,$); +#1076=IFCCLASSIFICATIONREFERENCE($,'21-02 30 20 10','Roof Accessories',#1075,$,$); +#1077=IFCCLASSIFICATIONREFERENCE($,'21-02 30 20 30','Roof Specialties',#1075,$,$); +#1078=IFCCLASSIFICATIONREFERENCE($,'21-02 30 20 70','Rainwater Management',#1075,$,$); +#1079=IFCCLASSIFICATIONREFERENCE($,'21-02 30 40','Traffic Bearing Horizontal Enclosures',#1069,$,$); +#1080=IFCCLASSIFICATIONREFERENCE($,'21-02 30 40 10','Traffic Bearing Coatings',#1079,$,$); +#1081=IFCCLASSIFICATIONREFERENCE($,'21-02 30 40 30','Horizontal Waterproofing Membrane',#1079,$,$); +#1082=IFCCLASSIFICATIONREFERENCE($,'21-02 30 40 50','Wear Surfaces',#1079,$,$); +#1083=IFCCLASSIFICATIONREFERENCE($,'21-02 30 40 90','Horizontal Enclosure Supplementary Components',#1079,$,$); +#1084=IFCCLASSIFICATIONREFERENCE($,'21-02 30 60','Horizontal Openings',#1069,$,$); +#1085=IFCCLASSIFICATIONREFERENCE($,'21-02 30 60 10','Roof Windows and Skylights',#1084,$,$); +#1086=IFCCLASSIFICATIONREFERENCE($,'21-02 30 60 50','Vents and Hatches',#1084,$,$); +#1087=IFCCLASSIFICATIONREFERENCE($,'21-02 30 60 90','Horizontal Opening Supplementary Components',#1084,$,$); +#1088=IFCCLASSIFICATIONREFERENCE($,'21-02 30 80','Overhead Exterior Enclosures',#1069,$,$); +#1089=IFCCLASSIFICATIONREFERENCE($,'21-02 30 80 10','Exterior Ceilings',#1088,$,$); +#1090=IFCCLASSIFICATIONREFERENCE($,'21-02 30 80 20','Exterior Soffits',#1088,$,$); +#1091=IFCCLASSIFICATIONREFERENCE($,'21-02 30 80 30','Exterior Bulkheads',#1088,$,$); +#1092=IFCCLASSIFICATIONREFERENCE($,'21-03 00 00','Interiors',#964,$,$); +#1093=IFCCLASSIFICATIONREFERENCE($,'21-03 10','Interior Construction',#1092,$,$); +#1094=IFCCLASSIFICATIONREFERENCE($,'21-03 10 10','Interior Partitions',#1093,$,$); +#1095=IFCCLASSIFICATIONREFERENCE($,'21-03 10 10 10','Interior Fixed Partitions',#1094,$,$); +#1096=IFCCLASSIFICATIONREFERENCE($,'21-03 10 10 20','Interior Glazed Partitions',#1094,$,$); +#1097=IFCCLASSIFICATIONREFERENCE($,'21-03 10 10 40','Interior Demountable Partitions',#1094,$,$); +#1098=IFCCLASSIFICATIONREFERENCE($,'21-03 10 10 50','Interior Operable Partitions',#1094,$,$); +#1099=IFCCLASSIFICATIONREFERENCE($,'21-03 10 10 70','Interior Screens',#1094,$,$); +#1100=IFCCLASSIFICATIONREFERENCE($,'21-03 10 10 90','Interior Partition Supplementary Components',#1094,$,$); +#1101=IFCCLASSIFICATIONREFERENCE($,'21-03 10 20','Interior Windows',#1093,$,$); +#1102=IFCCLASSIFICATIONREFERENCE($,'21-03 10 20 10','Interior Operating Windows',#1101,$,$); +#1103=IFCCLASSIFICATIONREFERENCE($,'21-03 10 20 20','Interior Fixed Windows',#1101,$,$); +#1104=IFCCLASSIFICATIONREFERENCE($,'21-03 10 20 50','Interior Special Function Windows',#1101,$,$); +#1105=IFCCLASSIFICATIONREFERENCE($,'21-03 10 20 90','Interior Window Supplementary Components',#1101,$,$); +#1106=IFCCLASSIFICATIONREFERENCE($,'21-03 10 30','Interior Doors',#1093,$,$); +#1107=IFCCLASSIFICATIONREFERENCE($,'21-03 10 30 10','Interior Swinging Doors',#1106,$,$); +#1108=IFCCLASSIFICATIONREFERENCE($,'21-03 10 30 20','Interior Entrance Doors',#1106,$,$); +#1109=IFCCLASSIFICATIONREFERENCE($,'21-03 10 30 25','Interior Sliding Doors',#1106,$,$); +#1110=IFCCLASSIFICATIONREFERENCE($,'21-03 10 30 30','Interior Folding Doors',#1106,$,$); +#1111=IFCCLASSIFICATIONREFERENCE($,'21-03 10 30 40','Interior Coiling Doors',#1106,$,$); +#1112=IFCCLASSIFICATIONREFERENCE($,'21-03 10 30 50','Interior Panel Doors',#1106,$,$); +#1113=IFCCLASSIFICATIONREFERENCE($,'21-03 10 30 70','Interior Special Function Doors',#1106,$,$); +#1114=IFCCLASSIFICATIONREFERENCE($,'21-03 10 30 80','Interior Access Doors and Panels',#1106,$,$); +#1115=IFCCLASSIFICATIONREFERENCE($,'21-03 10 30 90','Interior Door Supplementary Components',#1106,$,$); +#1116=IFCCLASSIFICATIONREFERENCE($,'21-03 10 40','Interior Grilles and Gates',#1093,$,$); +#1117=IFCCLASSIFICATIONREFERENCE($,'21-03 10 40 10','Interior Grilles',#1116,$,$); +#1118=IFCCLASSIFICATIONREFERENCE($,'21-03 10 40 50','Interior Gates',#1116,$,$); +#1119=IFCCLASSIFICATIONREFERENCE($,'21-03 10 60','Raised Floor Construction',#1093,$,$); +#1120=IFCCLASSIFICATIONREFERENCE($,'21-03 10 60 10','Access Flooring',#1119,$,$); +#1121=IFCCLASSIFICATIONREFERENCE($,'21-03 10 60 30','Platform/Stage Floors',#1119,$,$); +#1122=IFCCLASSIFICATIONREFERENCE($,'21-03 10 70','Suspended Ceiling Construction',#1093,$,$); +#1123=IFCCLASSIFICATIONREFERENCE($,'21-03 10 70 10','Acoustical Suspended Ceilings',#1122,$,$); +#1124=IFCCLASSIFICATIONREFERENCE($,'21-03 10 70 20','Suspended Plaster and Gypsum Board Ceilings',#1122,$,$); +#1125=IFCCLASSIFICATIONREFERENCE($,'21-03 10 70 50','Specialty Suspended Ceilings',#1122,$,$); +#1126=IFCCLASSIFICATIONREFERENCE($,'21-03 10 70 70','Special Function Suspended Ceilings',#1122,$,$); +#1127=IFCCLASSIFICATIONREFERENCE($,'21-03 10 70 90','Ceiling Suspension Components',#1122,$,$); +#1128=IFCCLASSIFICATIONREFERENCE($,'21-03 10 90','Interior Specialties',#1093,$,$); +#1129=IFCCLASSIFICATIONREFERENCE($,'21-03 10 90 10','Interior Railings and Handrails',#1128,$,$); +#1130=IFCCLASSIFICATIONREFERENCE($,'21-03 10 90 15','Interior Louvers',#1128,$,$); +#1131=IFCCLASSIFICATIONREFERENCE($,'21-03 10 90 20','Information Specialties',#1128,$,$); +#1132=IFCCLASSIFICATIONREFERENCE($,'21-03 10 90 25','Compartments and Cubicles',#1128,$,$); +#1133=IFCCLASSIFICATIONREFERENCE($,'21-03 10 90 30','Service Walls',#1128,$,$); +#1134=IFCCLASSIFICATIONREFERENCE($,'21-03 10 90 35','Wall and Door Protection',#1128,$,$); +#1135=IFCCLASSIFICATIONREFERENCE($,'21-03 10 90 40','Toilet, Bath, and Laundry Accessories',#1128,$,$); +#1136=IFCCLASSIFICATIONREFERENCE($,'21-03 10 90 45','Interior Gas Lighting',#1128,$,$); +#1137=IFCCLASSIFICATIONREFERENCE($,'21-03 10 90 50','Fireplaces and Stoves',#1128,$,$); +#1138=IFCCLASSIFICATIONREFERENCE($,'21-03 10 90 60','Safety Specialties',#1128,$,$); +#1139=IFCCLASSIFICATIONREFERENCE($,'21-03 10 90 70','Storage Specialties',#1128,$,$); +#1140=IFCCLASSIFICATIONREFERENCE($,'21-03 10 90 90','Other Interior Specialties',#1128,$,$); +#1141=IFCCLASSIFICATIONREFERENCE($,'21-03 20','Interior Finishes',#1092,$,$); +#1142=IFCCLASSIFICATIONREFERENCE($,'21-03 20 10','Wall Finishes',#1141,$,$); +#1143=IFCCLASSIFICATIONREFERENCE($,'21-03 20 10 10','Tile Wall Finish',#1142,$,$); +#1144=IFCCLASSIFICATIONREFERENCE($,'21-03 20 10 20','Wall Paneling',#1142,$,$); +#1145=IFCCLASSIFICATIONREFERENCE($,'21-03 20 10 30','Wall Coverings',#1142,$,$); +#1146=IFCCLASSIFICATIONREFERENCE($,'21-03 20 10 35','Wall Carpeting',#1142,$,$); +#1147=IFCCLASSIFICATIONREFERENCE($,'21-03 20 10 50','Stone Facing',#1142,$,$); +#1148=IFCCLASSIFICATIONREFERENCE($,'21-03 20 10 60','Special Wall Surfacing',#1142,$,$); +#1149=IFCCLASSIFICATIONREFERENCE($,'21-03 20 10 70','Wall Painting and Coating',#1142,$,$); +#1150=IFCCLASSIFICATIONREFERENCE($,'21-03 20 10 80','Acoustical Wall Treatment',#1142,$,$); +#1151=IFCCLASSIFICATIONREFERENCE($,'21-03 20 10 90','Wall Finish Supplementary Components',#1142,$,$); +#1152=IFCCLASSIFICATIONREFERENCE($,'21-03 20 20','Interior Fabrications',#1141,$,$); +#1153=IFCCLASSIFICATIONREFERENCE($,'21-03 20 30','Flooring',#1141,$,$); +#1154=IFCCLASSIFICATIONREFERENCE($,'21-03 20 30 10','Flooring Treatment',#1153,$,$); +#1155=IFCCLASSIFICATIONREFERENCE($,'21-03 20 30 20','Tile Flooring',#1153,$,$); +#1156=IFCCLASSIFICATIONREFERENCE($,'21-03 20 30 30','Specialty Flooring',#1153,$,$); +#1157=IFCCLASSIFICATIONREFERENCE($,'21-03 20 30 40','Masonry Flooring',#1153,$,$); +#1158=IFCCLASSIFICATIONREFERENCE($,'21-03 20 30 45','Wood Flooring',#1153,$,$); +#1159=IFCCLASSIFICATIONREFERENCE($,'21-03 20 30 50','Resilient Flooring',#1153,$,$); +#1160=IFCCLASSIFICATIONREFERENCE($,'21-03 20 30 60','Terrazzo Flooring',#1153,$,$); +#1161=IFCCLASSIFICATIONREFERENCE($,'21-03 20 30 70','Fluid-Applied Flooring',#1153,$,$); +#1162=IFCCLASSIFICATIONREFERENCE($,'21-03 20 30 75','Carpeting',#1153,$,$); +#1163=IFCCLASSIFICATIONREFERENCE($,'21-03 20 30 80','Athletic Flooring',#1153,$,$); +#1164=IFCCLASSIFICATIONREFERENCE($,'21-03 20 30 85','Entrance Flooring',#1153,$,$); +#1165=IFCCLASSIFICATIONREFERENCE($,'21-03 20 30 90','Flooring Supplementary Components',#1153,$,$); +#1166=IFCCLASSIFICATIONREFERENCE($,'21-03 20 40','Stair Finishes',#1141,$,$); +#1167=IFCCLASSIFICATIONREFERENCE($,'21-03 20 40 20','Tile Stair Finish',#1166,$,$); +#1168=IFCCLASSIFICATIONREFERENCE($,'21-03 20 40 40','Masonry Stair Finish',#1166,$,$); +#1169=IFCCLASSIFICATIONREFERENCE($,'21-03 20 40 45','Wood Stair Finish',#1166,$,$); +#1170=IFCCLASSIFICATIONREFERENCE($,'21-03 20 40 50','Resilient Stair Finish',#1166,$,$); +#1171=IFCCLASSIFICATIONREFERENCE($,'21-03 20 40 60','Terrazzo Stair Finish',#1166,$,$); +#1172=IFCCLASSIFICATIONREFERENCE($,'21-03 20 40 75','Carpeted Stair Finish',#1166,$,$); +#1173=IFCCLASSIFICATIONREFERENCE($,'21-03 20 50','Ceiling Finishes',#1141,$,$); +#1174=IFCCLASSIFICATIONREFERENCE($,'21-03 20 50 10','Plaster and Gypsum Board Finish',#1173,$,$); +#1175=IFCCLASSIFICATIONREFERENCE($,'21-03 20 50 20','Ceiling Paneling',#1173,$,$); +#1176=IFCCLASSIFICATIONREFERENCE($,'21-03 20 50 70','Ceiling Painting and Coating',#1173,$,$); +#1177=IFCCLASSIFICATIONREFERENCE($,'21-03 20 50 80','Acoustical Ceiling Treatment',#1173,$,$); +#1178=IFCCLASSIFICATIONREFERENCE($,'21-03 20 50 90','Ceiling Finish Supplementary Components',#1173,$,$); +#1179=IFCCLASSIFICATIONREFERENCE($,'21-04 00 00','Services',#964,$,$); +#1180=IFCCLASSIFICATIONREFERENCE($,'21-04 10','Conveying',#1179,$,$); +#1181=IFCCLASSIFICATIONREFERENCE($,'21-04 10 10','Vertical Conveying Systems',#1180,$,$); +#1182=IFCCLASSIFICATIONREFERENCE($,'21-04 10 10 10','Elevators',#1181,$,$); +#1183=IFCCLASSIFICATIONREFERENCE($,'21-04 10 10 20','Lifts',#1181,$,$); +#1184=IFCCLASSIFICATIONREFERENCE($,'21-04 10 10 30','Escalators',#1181,$,$); +#1185=IFCCLASSIFICATIONREFERENCE($,'21-04 10 10 50','Dumbwaiters',#1181,$,$); +#1186=IFCCLASSIFICATIONREFERENCE($,'21-04 10 10 60','Moving Ramps',#1181,$,$); +#1187=IFCCLASSIFICATIONREFERENCE($,'21-04 10 30','Horizontal Conveying',#1180,$,$); +#1188=IFCCLASSIFICATIONREFERENCE($,'21-04 10 30 10','Moving Walks',#1187,$,$); +#1189=IFCCLASSIFICATIONREFERENCE($,'21-04 10 30 30','Turntables',#1187,$,$); +#1190=IFCCLASSIFICATIONREFERENCE($,'21-04 10 30 50','Passenger Loading Bridges',#1187,$,$); +#1191=IFCCLASSIFICATIONREFERENCE($,'21-04 10 30 70','People Movers',#1187,$,$); +#1192=IFCCLASSIFICATIONREFERENCE($,'21-04 10 50','Material Handling',#1180,$,$); +#1193=IFCCLASSIFICATIONREFERENCE($,'21-04 10 50 10','Cranes',#1192,$,$); +#1194=IFCCLASSIFICATIONREFERENCE($,'21-04 10 50 20','Hoists',#1192,$,$); +#1195=IFCCLASSIFICATIONREFERENCE($,'21-04 10 50 30','Derricks',#1192,$,$); +#1196=IFCCLASSIFICATIONREFERENCE($,'21-04 10 50 40','Conveyors',#1192,$,$); +#1197=IFCCLASSIFICATIONREFERENCE($,'21-04 10 50 50','Baggage Handling Equipment',#1192,$,$); +#1198=IFCCLASSIFICATIONREFERENCE($,'21-04 10 50 60','Chutes',#1192,$,$); +#1199=IFCCLASSIFICATIONREFERENCE($,'21-04 10 50 70','Pneumatic Tube Systems',#1192,$,$); +#1200=IFCCLASSIFICATIONREFERENCE($,'21-04 10 80','Operable Access Systems',#1180,$,$); +#1201=IFCCLASSIFICATIONREFERENCE($,'21-04 10 80 10','Suspended Scaffolding',#1200,$,$); +#1202=IFCCLASSIFICATIONREFERENCE($,'21-04 10 80 20','Rope Climbers',#1200,$,$); +#1203=IFCCLASSIFICATIONREFERENCE($,'21-04 10 80 30','Elevating Platforms',#1200,$,$); +#1204=IFCCLASSIFICATIONREFERENCE($,'21-04 10 80 40','Powered Scaffolding',#1200,$,$); +#1205=IFCCLASSIFICATIONREFERENCE($,'21-04 10 80 50','Building Envelope Access',#1200,$,$); +#1206=IFCCLASSIFICATIONREFERENCE($,'21-04 20','Plumbing',#1179,$,$); +#1207=IFCCLASSIFICATIONREFERENCE($,'21-04 20 10','Domestic Water Distribution',#1206,$,$); +#1208=IFCCLASSIFICATIONREFERENCE($,'21-04 20 10 10','Facility Potable-Water Storage Tanks',#1207,$,$); +#1209=IFCCLASSIFICATIONREFERENCE($,'21-04 20 10 20','Domestic Water Equipment',#1207,$,$); +#1210=IFCCLASSIFICATIONREFERENCE($,'21-04 20 10 40','Domestic Water Piping',#1207,$,$); +#1211=IFCCLASSIFICATIONREFERENCE($,'21-04 20 10 60','Plumbing Fixtures',#1207,$,$); +#1212=IFCCLASSIFICATIONREFERENCE($,'21-04 20 10 90','Domestic Water Distribution Supplementary Components',#1207,$,$); +#1213=IFCCLASSIFICATIONREFERENCE($,'21-04 20 20','Sanitary Drainage',#1206,$,$); +#1214=IFCCLASSIFICATIONREFERENCE($,'21-04 20 20 10','Sanitary Sewerage Equipment',#1213,$,$); +#1215=IFCCLASSIFICATIONREFERENCE($,'21-04 20 20 30','Sanitary Sewerage Piping',#1213,$,$); +#1216=IFCCLASSIFICATIONREFERENCE($,'21-04 20 20 90','Sanitary Drainage Supplementary Components',#1213,$,$); +#1217=IFCCLASSIFICATIONREFERENCE($,'21-04 20 30','Building Support Plumbing Systems',#1206,$,$); +#1218=IFCCLASSIFICATIONREFERENCE($,'21-04 20 30 10','Stormwater Drainage Equipment',#1217,$,$); +#1219=IFCCLASSIFICATIONREFERENCE($,'21-04 20 30 20','Stormwater Drainage Piping',#1217,$,$); +#1220=IFCCLASSIFICATIONREFERENCE($,'21-04 20 30 30','Facility Stormwater Drains',#1217,$,$); +#1221=IFCCLASSIFICATIONREFERENCE($,'21-04 20 30 60','Gray Water Systems',#1217,$,$); +#1222=IFCCLASSIFICATIONREFERENCE($,'21-04 20 30 90','Building Support Plumbing System Supplementary Components',#1217,$,$); +#1223=IFCCLASSIFICATIONREFERENCE($,'21-04 20 50','General Service Compressed-Air',#1206,$,$); +#1224=IFCCLASSIFICATIONREFERENCE($,'21-04 20 60','Process Support Plumbing Systems',#1206,$,$); +#1225=IFCCLASSIFICATIONREFERENCE($,'21-04 20 60 10','Compressed-Air Systems',#1224,$,$); +#1226=IFCCLASSIFICATIONREFERENCE($,'21-04 20 60 20','Vacuum Systems',#1224,$,$); +#1227=IFCCLASSIFICATIONREFERENCE($,'21-04 20 60 30','Gas Systems',#1224,$,$); +#1228=IFCCLASSIFICATIONREFERENCE($,'21-04 20 60 40','Chemical-Waste Systems',#1224,$,$); +#1229=IFCCLASSIFICATIONREFERENCE($,'21-04 20 60 50','Processed Water Systems',#1224,$,$); +#1230=IFCCLASSIFICATIONREFERENCE($,'21-04 20 60 90','Process Support Plumbing System Supplementary Components',#1224,$,$); +#1231=IFCCLASSIFICATIONREFERENCE($,'21-04 30','Heating, Ventilation, and Air Conditioning (HVAC)',#1179,$,$); +#1232=IFCCLASSIFICATIONREFERENCE($,'21-04 30 10','Facility Fuel Systems',#1231,$,$); +#1233=IFCCLASSIFICATIONREFERENCE($,'21-04 30 10 10','Fuel Piping',#1232,$,$); +#1234=IFCCLASSIFICATIONREFERENCE($,'21-04 30 10 30','Fuel Pumps',#1232,$,$); +#1235=IFCCLASSIFICATIONREFERENCE($,'21-04 30 10 50','Fuel Storage Tanks',#1232,$,$); +#1236=IFCCLASSIFICATIONREFERENCE($,'21-04 30 20','Heating Systems',#1231,$,$); +#1237=IFCCLASSIFICATIONREFERENCE($,'21-04 30 20 10','Heat Generation',#1236,$,$); +#1238=IFCCLASSIFICATIONREFERENCE($,'21-04 30 20 30','Thermal Heat Storage',#1236,$,$); +#1239=IFCCLASSIFICATIONREFERENCE($,'21-04 30 20 70','Decentralized Heating Equipment',#1236,$,$); +#1240=IFCCLASSIFICATIONREFERENCE($,'21-04 30 20 90','Heating System Supplementary Components',#1236,$,$); +#1241=IFCCLASSIFICATIONREFERENCE($,'21-04 30 30','Cooling Systems',#1231,$,$); +#1242=IFCCLASSIFICATIONREFERENCE($,'21-04 30 30 10','Central Cooling',#1241,$,$); +#1243=IFCCLASSIFICATIONREFERENCE($,'21-04 30 30 30','Evaporative Air-Cooling',#1241,$,$); +#1244=IFCCLASSIFICATIONREFERENCE($,'21-04 30 30 50','Thermal Cooling Storage',#1241,$,$); +#1245=IFCCLASSIFICATIONREFERENCE($,'21-04 30 30 70','Decentralized Cooling',#1241,$,$); +#1246=IFCCLASSIFICATIONREFERENCE($,'21-04 30 30 90','Cooling System Supplementary Components',#1241,$,$); +#1247=IFCCLASSIFICATIONREFERENCE($,'21-04 30 50','Facility HVAC Distribution Systems',#1231,$,$); +#1248=IFCCLASSIFICATIONREFERENCE($,'21-04 30 50 10','Facility Hydronic Distribution',#1247,$,$); +#1249=IFCCLASSIFICATIONREFERENCE($,'21-04 30 50 30','Facility Steam Distribution',#1247,$,$); +#1250=IFCCLASSIFICATIONREFERENCE($,'21-04 30 50 50','HVAC Air Distribution',#1247,$,$); +#1251=IFCCLASSIFICATIONREFERENCE($,'21-04 30 50 90','Facility Distribution Systems Supplementary Components',#1247,$,$); +#1252=IFCCLASSIFICATIONREFERENCE($,'21-04 30 60','Ventilation',#1231,$,$); +#1253=IFCCLASSIFICATIONREFERENCE($,'21-04 30 60 10','Supply Air',#1252,$,$); +#1254=IFCCLASSIFICATIONREFERENCE($,'21-04 30 60 20','Return Air',#1252,$,$); +#1255=IFCCLASSIFICATIONREFERENCE($,'21-04 30 60 30','Exhaust Air',#1252,$,$); +#1256=IFCCLASSIFICATIONREFERENCE($,'21-04 30 60 40','Outside Air',#1252,$,$); +#1257=IFCCLASSIFICATIONREFERENCE($,'21-04 30 60 60','Air-to-Air Energy Recovery',#1252,$,$); +#1258=IFCCLASSIFICATIONREFERENCE($,'21-04 30 60 70','HVAC Air Cleaning',#1252,$,$); +#1259=IFCCLASSIFICATIONREFERENCE($,'21-04 30 60 90','Ventilation Supplementary Components',#1252,$,$); +#1260=IFCCLASSIFICATIONREFERENCE($,'21-04 30 70','Special Purpose HVAC Systems',#1231,$,$); +#1261=IFCCLASSIFICATIONREFERENCE($,'21-04 30 70 10','Snow Melting',#1260,$,$); +#1262=IFCCLASSIFICATIONREFERENCE($,'21-04 40','Fire Protection',#1179,$,$); +#1263=IFCCLASSIFICATIONREFERENCE($,'21-04 40 10','Fire Suppression',#1262,$,$); +#1264=IFCCLASSIFICATIONREFERENCE($,'21-04 40 10 10','Water-Based Fire-Suppression',#1263,$,$); +#1265=IFCCLASSIFICATIONREFERENCE($,'21-04 40 10 50','Fire-Extinguishing',#1263,$,$); +#1266=IFCCLASSIFICATIONREFERENCE($,'21-04 40 10 90','Fire Suppression Supplementary Components',#1263,$,$); +#1267=IFCCLASSIFICATIONREFERENCE($,'21-04 40 30','Fire Protection Specialties',#1262,$,$); +#1268=IFCCLASSIFICATIONREFERENCE($,'21-04 40 30 10','Fire Protection Cabinets',#1267,$,$); +#1269=IFCCLASSIFICATIONREFERENCE($,'21-04 40 30 30','Fire Extinguishers',#1267,$,$); +#1270=IFCCLASSIFICATIONREFERENCE($,'21-04 40 30 50','Breathing Air Replenishment Systems',#1267,$,$); +#1271=IFCCLASSIFICATIONREFERENCE($,'21-04 40 30 70','Fire Extinguisher Accessories',#1267,$,$); +#1272=IFCCLASSIFICATIONREFERENCE($,'21-04 50','Electrical',#1179,$,$); +#1273=IFCCLASSIFICATIONREFERENCE($,'21-04 50 10','Facility Power Generation',#1272,$,$); +#1274=IFCCLASSIFICATIONREFERENCE($,'21-04 50 10 10','Packaged Generator Assemblies',#1273,$,$); +#1275=IFCCLASSIFICATIONREFERENCE($,'21-04 50 10 20','Battery Equipment',#1273,$,$); +#1276=IFCCLASSIFICATIONREFERENCE($,'21-04 50 10 30','Photovoltaic Collectors',#1273,$,$); +#1277=IFCCLASSIFICATIONREFERENCE($,'21-04 50 10 40','Fuel Cells',#1273,$,$); +#1278=IFCCLASSIFICATIONREFERENCE($,'21-04 50 10 60','Power Filtering and Conditioning',#1273,$,$); +#1279=IFCCLASSIFICATIONREFERENCE($,'21-04 50 10 70','Transfer Switches',#1273,$,$); +#1280=IFCCLASSIFICATIONREFERENCE($,'21-04 50 10 90','Facility Power Generation Supplementary Components',#1273,$,$); +#1281=IFCCLASSIFICATIONREFERENCE($,'21-04 50 20','Electrical Service and Distribution',#1272,$,$); +#1282=IFCCLASSIFICATIONREFERENCE($,'21-04 50 20 10','Electrical Service',#1281,$,$); +#1283=IFCCLASSIFICATIONREFERENCE($,'21-04 50 20 30','Power Distribution',#1281,$,$); +#1284=IFCCLASSIFICATIONREFERENCE($,'21-04 50 20 70','Facility Grounding',#1281,$,$); +#1285=IFCCLASSIFICATIONREFERENCE($,'21-04 50 20 90','Electrical Service and Distribution Supplementary Components',#1281,$,$); +#1286=IFCCLASSIFICATIONREFERENCE($,'21-04 50 30','General Purpose Electrical Power',#1272,$,$); +#1287=IFCCLASSIFICATIONREFERENCE($,'21-04 50 30 10','Branch Wiring System',#1286,$,$); +#1288=IFCCLASSIFICATIONREFERENCE($,'21-04 50 30 50','Wiring Devices',#1286,$,$); +#1289=IFCCLASSIFICATIONREFERENCE($,'21-04 50 30 90','General Purpose Electrical Power Supplementary Components',#1286,$,$); +#1290=IFCCLASSIFICATIONREFERENCE($,'21-04 50 40','Lighting',#1272,$,$); +#1291=IFCCLASSIFICATIONREFERENCE($,'21-04 50 40 10','Lighting Control',#1290,$,$); +#1292=IFCCLASSIFICATIONREFERENCE($,'21-04 50 40 20','Branch Wiring for Lighting',#1290,$,$); +#1293=IFCCLASSIFICATIONREFERENCE($,'21-04 50 40 50','Lighting Fixtures',#1290,$,$); +#1294=IFCCLASSIFICATIONREFERENCE($,'21-04 50 40 90','Lighting Supplementary Components',#1290,$,$); +#1295=IFCCLASSIFICATIONREFERENCE($,'21-04 50 80','Miscellaneous Electrical Systems',#1272,$,$); +#1296=IFCCLASSIFICATIONREFERENCE($,'21-04 50 80 10','Lightning Protection',#1295,$,$); +#1297=IFCCLASSIFICATIONREFERENCE($,'21-04 50 80 40','Cathodic Protection',#1295,$,$); +#1298=IFCCLASSIFICATIONREFERENCE($,'21-04 50 80 70','Transient Voltage Suppression',#1295,$,$); +#1299=IFCCLASSIFICATIONREFERENCE($,'21-04 50 80 90','Miscellaneous Electrical Systems Supplementary Components',#1295,$,$); +#1300=IFCCLASSIFICATIONREFERENCE($,'21-04 60','Communications',#1179,$,$); +#1301=IFCCLASSIFICATIONREFERENCE($,'21-04 60 10','Data Communications',#1300,$,$); +#1302=IFCCLASSIFICATIONREFERENCE($,'21-04 60 10 10','Data Communications Network Equipment',#1301,$,$); +#1303=IFCCLASSIFICATIONREFERENCE($,'21-04 60 10 20','Data Communications Hardware',#1301,$,$); +#1304=IFCCLASSIFICATIONREFERENCE($,'21-04 60 10 30','Data Communications Peripheral Data Equipment',#1301,$,$); +#1305=IFCCLASSIFICATIONREFERENCE($,'21-04 60 10 50','Data Communications Software',#1301,$,$); +#1306=IFCCLASSIFICATIONREFERENCE($,'21-04 60 10 60','Data Communication Program and Integration Services',#1301,$,$); +#1307=IFCCLASSIFICATIONREFERENCE($,'21-04 60 20','Voice Communications',#1300,$,$); +#1308=IFCCLASSIFICATIONREFERENCE($,'21-04 60 20 10','Voice Communications Switching and Routing Equipment',#1307,$,$); +#1309=IFCCLASSIFICATIONREFERENCE($,'21-04 60 20 20','Voice Communications Terminal Equipment',#1307,$,$); +#1310=IFCCLASSIFICATIONREFERENCE($,'21-04 60 20 30','Voice Communications Messaging',#1307,$,$); +#1311=IFCCLASSIFICATIONREFERENCE($,'21-04 60 20 40','Call Accounting',#1307,$,$); +#1312=IFCCLASSIFICATIONREFERENCE($,'21-04 60 20 50','Call Management',#1307,$,$); +#1313=IFCCLASSIFICATIONREFERENCE($,'21-04 60 30','Audio-Video Communication',#1300,$,$); +#1314=IFCCLASSIFICATIONREFERENCE($,'21-04 60 30 10','Audio-Video Systems',#1313,$,$); +#1315=IFCCLASSIFICATIONREFERENCE($,'21-04 60 30 50','Electronic Digital Systems',#1313,$,$); +#1316=IFCCLASSIFICATIONREFERENCE($,'21-04 60 60','Distributed Communications and Monitoring',#1300,$,$); +#1317=IFCCLASSIFICATIONREFERENCE($,'21-04 60 60 10','Distributed Audio-Video Communications Systems',#1316,$,$); +#1318=IFCCLASSIFICATIONREFERENCE($,'21-04 60 60 30','Healthcare Communications and Monitoring',#1316,$,$); +#1319=IFCCLASSIFICATIONREFERENCE($,'21-04 60 60 50','Distributed Systems',#1316,$,$); +#1320=IFCCLASSIFICATIONREFERENCE($,'21-04 60 90','Communications Supplementary Components',#1300,$,$); +#1321=IFCCLASSIFICATIONREFERENCE($,'21-04 60 90 10','Supplementary Components',#1320,$,$); +#1322=IFCCLASSIFICATIONREFERENCE($,'21-04 70','Electronic Safety and Security',#1179,$,$); +#1323=IFCCLASSIFICATIONREFERENCE($,'21-04 70 10','Access Control and Intrusion Detection',#1322,$,$); +#1324=IFCCLASSIFICATIONREFERENCE($,'21-04 70 10 10','Access Control',#1323,$,$); +#1325=IFCCLASSIFICATIONREFERENCE($,'21-04 70 10 50','Intrusion Detection',#1323,$,$); +#1326=IFCCLASSIFICATIONREFERENCE($,'21-04 70 30','Electronic Surveillance',#1322,$,$); +#1327=IFCCLASSIFICATIONREFERENCE($,'21-04 70 30 10','Video Surveillance',#1326,$,$); +#1328=IFCCLASSIFICATIONREFERENCE($,'21-04 70 30 50','Electronic Personal Protection',#1326,$,$); +#1329=IFCCLASSIFICATIONREFERENCE($,'21-04 70 50','Detection and Alarm',#1322,$,$); +#1330=IFCCLASSIFICATIONREFERENCE($,'21-04 70 50 10','Fire Detection and Alarm',#1329,$,$); +#1331=IFCCLASSIFICATIONREFERENCE($,'21-04 70 50 20','Radiation Detection and Alarm',#1329,$,$); +#1332=IFCCLASSIFICATIONREFERENCE($,'21-04 70 50 30','Fuel-Gas Detection and Alarm',#1329,$,$); +#1333=IFCCLASSIFICATIONREFERENCE($,'21-04 70 50 40','Fuel-Oil Detection and Alarm',#1329,$,$); +#1334=IFCCLASSIFICATIONREFERENCE($,'21-04 70 50 50','Refrigeration Detection and Alarm',#1329,$,$); +#1335=IFCCLASSIFICATIONREFERENCE($,'21-04 70 50 60','Water Intrusion Detection and Alarm',#1329,$,$); +#1336=IFCCLASSIFICATIONREFERENCE($,'21-04 70 70','Electronic Monitoring and Control',#1322,$,$); +#1337=IFCCLASSIFICATIONREFERENCE($,'21-04 70 70 10','Electronic Detention Monitoring and Control',#1336,$,$); +#1338=IFCCLASSIFICATIONREFERENCE($,'21-04 70 90','Electronic Safety and Security Supplementary Components',#1322,$,$); +#1339=IFCCLASSIFICATIONREFERENCE($,'21-04 70 90 10','Supplementary Components',#1338,$,$); +#1340=IFCCLASSIFICATIONREFERENCE($,'21-04 80','Integrated Automation',#1179,$,$); +#1341=IFCCLASSIFICATIONREFERENCE($,'21-04 80 10','Integrated Automation Facility Controls',#1340,$,$); +#1342=IFCCLASSIFICATIONREFERENCE($,'21-04 80 10 10','Integrated Automation Control of Equipment',#1341,$,$); +#1343=IFCCLASSIFICATIONREFERENCE($,'21-04 80 10 20','Integrated Automation Control of Conveying Equipment',#1341,$,$); +#1344=IFCCLASSIFICATIONREFERENCE($,'21-04 80 10 30','Integrated Automation Control of Fire-Suppression Systems',#1341,$,$); +#1345=IFCCLASSIFICATIONREFERENCE($,'21-04 80 10 40','Integrated Automation Control of Plumbing Systems',#1341,$,$); +#1346=IFCCLASSIFICATIONREFERENCE($,'21-04 80 10 50','Integrated Automation Control of HVAC Systems',#1341,$,$); +#1347=IFCCLASSIFICATIONREFERENCE($,'21-04 80 10 60','Integrated Automation Control of Electrical Systems',#1341,$,$); +#1348=IFCCLASSIFICATIONREFERENCE($,'21-04 80 10 70','Integrated Automation Control of Communication Systems',#1341,$,$); +#1349=IFCCLASSIFICATIONREFERENCE($,'21-04 80 10 80','Integrated Automation Control of Electronic Safety and Security Systems',#1341,$,$); +#1350=IFCCLASSIFICATIONREFERENCE($,'21-04 80 10 90','Integrated Automation Supplementary Components',#1341,$,$); +#1351=IFCCLASSIFICATIONREFERENCE($,'21-05 00 00','Equipment and Furnishings',#964,$,$); +#1352=IFCCLASSIFICATIONREFERENCE($,'21-05 10','Equipment',#1351,$,$); +#1353=IFCCLASSIFICATIONREFERENCE($,'21-05 10 10','Vehicle and Pedestrian Equipment',#1352,$,$); +#1354=IFCCLASSIFICATIONREFERENCE($,'21-05 10 10 10','Vehicle Servicing Equipment',#1353,$,$); +#1355=IFCCLASSIFICATIONREFERENCE($,'21-05 10 10 30','Interior Parking Control Equipment',#1353,$,$); +#1356=IFCCLASSIFICATIONREFERENCE($,'21-05 10 10 50','Loading Dock Equipment',#1353,$,$); +#1357=IFCCLASSIFICATIONREFERENCE($,'21-05 10 10 70','Interior Pedestrian Control Equipment',#1353,$,$); +#1358=IFCCLASSIFICATIONREFERENCE($,'21-05 10 30','Commercial Equipment',#1352,$,$); +#1359=IFCCLASSIFICATIONREFERENCE($,'21-05 10 30 10','Mercantile and Service Equipment',#1358,$,$); +#1360=IFCCLASSIFICATIONREFERENCE($,'21-05 10 30 20','Vault Equipment',#1358,$,$); +#1361=IFCCLASSIFICATIONREFERENCE($,'21-05 10 30 25','Teller and Service Equipment',#1358,$,$); +#1362=IFCCLASSIFICATIONREFERENCE($,'21-05 10 30 30','Refrigerated Display Equipment',#1358,$,$); +#1363=IFCCLASSIFICATIONREFERENCE($,'21-05 10 30 35','Commercial Laundry and Dry Cleaning Equipment',#1358,$,$); +#1364=IFCCLASSIFICATIONREFERENCE($,'21-05 10 30 40','Maintenance Equipment',#1358,$,$); +#1365=IFCCLASSIFICATIONREFERENCE($,'21-05 10 30 50','Hospitality Equipment',#1358,$,$); +#1366=IFCCLASSIFICATIONREFERENCE($,'21-05 10 30 55','Unit Kitchens',#1358,$,$); +#1367=IFCCLASSIFICATIONREFERENCE($,'21-05 10 30 60','Photographic Processing Equipment',#1358,$,$); +#1368=IFCCLASSIFICATIONREFERENCE($,'21-05 10 30 70','Postal, Packaging, and Shipping Equipment',#1358,$,$); +#1369=IFCCLASSIFICATIONREFERENCE($,'21-05 10 30 75','Office Equipment',#1358,$,$); +#1370=IFCCLASSIFICATIONREFERENCE($,'21-05 10 30 80','Foodservice Equipment',#1358,$,$); +#1371=IFCCLASSIFICATIONREFERENCE($,'21-05 10 40','Institutional Equipment',#1352,$,$); +#1372=IFCCLASSIFICATIONREFERENCE($,'21-05 10 40 10','Educational and Scientific Equipment',#1371,$,$); +#1373=IFCCLASSIFICATIONREFERENCE($,'21-05 10 40 20','Healthcare Equipment',#1371,$,$); +#1374=IFCCLASSIFICATIONREFERENCE($,'21-05 10 40 40','Religious Equipment',#1371,$,$); +#1375=IFCCLASSIFICATIONREFERENCE($,'21-05 10 40 60','Security Equipment',#1371,$,$); +#1376=IFCCLASSIFICATIONREFERENCE($,'21-05 10 40 70','Detention Equipment',#1371,$,$); +#1377=IFCCLASSIFICATIONREFERENCE($,'21-05 10 60','Residential Equipment',#1352,$,$); +#1378=IFCCLASSIFICATIONREFERENCE($,'21-05 10 60 10','Residential Appliances',#1377,$,$); +#1379=IFCCLASSIFICATIONREFERENCE($,'21-05 10 60 50','Retractable Stairs',#1377,$,$); +#1380=IFCCLASSIFICATIONREFERENCE($,'21-05 10 60 70','Residential Ceiling Fans',#1377,$,$); +#1381=IFCCLASSIFICATIONREFERENCE($,'21-05 10 70','Entertainment and Recreational Equipment',#1352,$,$); +#1382=IFCCLASSIFICATIONREFERENCE($,'21-05 10 70 10','Theater and Stage Equipment',#1381,$,$); +#1383=IFCCLASSIFICATIONREFERENCE($,'21-05 10 70 20','Musical Equipment',#1381,$,$); +#1384=IFCCLASSIFICATIONREFERENCE($,'21-05 10 70 50','Athletic Equipment',#1381,$,$); +#1385=IFCCLASSIFICATIONREFERENCE($,'21-05 10 70 60','Recreational Equipment',#1381,$,$); +#1386=IFCCLASSIFICATIONREFERENCE($,'21-05 10 90','Other Equipment',#1352,$,$); +#1387=IFCCLASSIFICATIONREFERENCE($,'21-05 10 90 10','Solid Waste Handling Equipment',#1386,$,$); +#1388=IFCCLASSIFICATIONREFERENCE($,'21-05 10 90 30','Agricultural Equipment',#1386,$,$); +#1389=IFCCLASSIFICATIONREFERENCE($,'21-05 10 90 40','Horticultural Equipment',#1386,$,$); +#1390=IFCCLASSIFICATIONREFERENCE($,'21-05 10 90 60','Decontamination Equipment',#1386,$,$); +#1391=IFCCLASSIFICATIONREFERENCE($,'21-05 20','Furnishings',#1351,$,$); +#1392=IFCCLASSIFICATIONREFERENCE($,'21-05 20 10','Fixed Furnishings',#1391,$,$); +#1393=IFCCLASSIFICATIONREFERENCE($,'21-05 20 10 10','Fixed Art',#1392,$,$); +#1394=IFCCLASSIFICATIONREFERENCE($,'21-05 20 10 20','Window Treatments',#1392,$,$); +#1395=IFCCLASSIFICATIONREFERENCE($,'21-05 20 10 30','Casework',#1392,$,$); +#1396=IFCCLASSIFICATIONREFERENCE($,'21-05 20 10 70','Fixed Multiple Seating',#1392,$,$); +#1397=IFCCLASSIFICATIONREFERENCE($,'21-05 20 10 90','Other Fixed Furnishings',#1392,$,$); +#1398=IFCCLASSIFICATIONREFERENCE($,'21-05 20 50','Movable Furnishings',#1391,$,$); +#1399=IFCCLASSIFICATIONREFERENCE($,'21-05 20 50 10','Movable Art',#1398,$,$); +#1400=IFCCLASSIFICATIONREFERENCE($,'21-05 20 50 30','Furniture',#1398,$,$); +#1401=IFCCLASSIFICATIONREFERENCE($,'21-05 20 50 40','Accessories',#1398,$,$); +#1402=IFCCLASSIFICATIONREFERENCE($,'21-05 20 50 60','Movable Multiple Seating',#1398,$,$); +#1403=IFCCLASSIFICATIONREFERENCE($,'21-05 20 50 90','Other Movable Furnishings',#1398,$,$); +#1404=IFCCLASSIFICATIONREFERENCE($,'21-06 00 00','Special Construction and Demolition',#964,$,$); +#1405=IFCCLASSIFICATIONREFERENCE($,'21-06 10','Special Construction',#1404,$,$); +#1406=IFCCLASSIFICATIONREFERENCE($,'21-06 10 10','Integrated Construction',#1405,$,$); +#1407=IFCCLASSIFICATIONREFERENCE($,'21-06 10 10 10','Building Modules',#1406,$,$); +#1408=IFCCLASSIFICATIONREFERENCE($,'21-06 10 10 50','Manufactured/Fabricated Rooms',#1406,$,$); +#1409=IFCCLASSIFICATIONREFERENCE($,'21-06 10 10 70','Modular Mezzanines',#1406,$,$); +#1410=IFCCLASSIFICATIONREFERENCE($,'21-06 10 20','Special Structures',#1405,$,$); +#1411=IFCCLASSIFICATIONREFERENCE($,'21-06 10 20 10','Fabric Structures',#1410,$,$); +#1412=IFCCLASSIFICATIONREFERENCE($,'21-06 10 20 20','Space Frames',#1410,$,$); +#1413=IFCCLASSIFICATIONREFERENCE($,'21-06 10 20 30','Geodesic Structures',#1410,$,$); +#1414=IFCCLASSIFICATIONREFERENCE($,'21-06 10 20 40','Manufacturer-Engineered Structures',#1410,$,$); +#1415=IFCCLASSIFICATIONREFERENCE($,'21-06 10 20 60','Manufactured Canopies',#1410,$,$); +#1416=IFCCLASSIFICATIONREFERENCE($,'21-06 10 20 65','Rammed Earth Construction',#1410,$,$); +#1417=IFCCLASSIFICATIONREFERENCE($,'21-06 10 20 70','Towers',#1410,$,$); +#1418=IFCCLASSIFICATIONREFERENCE($,'21-06 10 30','Special Function Construction',#1405,$,$); +#1419=IFCCLASSIFICATIONREFERENCE($,'21-06 10 30 10','Sound and Vibration Control',#1418,$,$); +#1420=IFCCLASSIFICATIONREFERENCE($,'21-06 10 30 30','Seismic Control',#1418,$,$); +#1421=IFCCLASSIFICATIONREFERENCE($,'21-06 10 30 50','Radiation Protection',#1418,$,$); +#1422=IFCCLASSIFICATIONREFERENCE($,'21-06 10 50','Special Facility Components',#1405,$,$); +#1423=IFCCLASSIFICATIONREFERENCE($,'21-06 10 50 10','Pools',#1422,$,$); +#1424=IFCCLASSIFICATIONREFERENCE($,'21-06 10 50 20','Interior Fountains',#1422,$,$); +#1425=IFCCLASSIFICATIONREFERENCE($,'21-06 10 50 30','Interior Water Features',#1422,$,$); +#1426=IFCCLASSIFICATIONREFERENCE($,'21-06 10 50 40','Aquariums',#1422,$,$); +#1427=IFCCLASSIFICATIONREFERENCE($,'21-06 10 50 50','Amusement Park Structures and Equipment',#1422,$,$); +#1428=IFCCLASSIFICATIONREFERENCE($,'21-06 10 50 60','Ice Rinks',#1422,$,$); +#1429=IFCCLASSIFICATIONREFERENCE($,'21-06 10 50 70','Animal Containment',#1422,$,$); +#1430=IFCCLASSIFICATIONREFERENCE($,'21-06 10 60','Athletic and Recreational Special Construction',#1405,$,$); +#1431=IFCCLASSIFICATIONREFERENCE($,'21-06 10 60 10','Indoor Soccer Boards',#1430,$,$); +#1432=IFCCLASSIFICATIONREFERENCE($,'21-06 10 60 20','Safety Netting',#1430,$,$); +#1433=IFCCLASSIFICATIONREFERENCE($,'21-06 10 60 30','Arena Football Boards',#1430,$,$); +#1434=IFCCLASSIFICATIONREFERENCE($,'21-06 10 60 40','Floor Sockets',#1430,$,$); +#1435=IFCCLASSIFICATIONREFERENCE($,'21-06 10 60 50','Athletic and Recreational Court Walls',#1430,$,$); +#1436=IFCCLASSIFICATIONREFERENCE($,'21-06 10 60 60','Demountable Athletic Surfaces',#1430,$,$); +#1437=IFCCLASSIFICATIONREFERENCE($,'21-06 10 80','Special Instrumentation',#1405,$,$); +#1438=IFCCLASSIFICATIONREFERENCE($,'21-06 10 80 10','Stress Instrumentation',#1437,$,$); +#1439=IFCCLASSIFICATIONREFERENCE($,'21-06 10 80 20','Seismic Instrumentation',#1437,$,$); +#1440=IFCCLASSIFICATIONREFERENCE($,'21-06 10 80 40','Meteorological Instrumentation',#1437,$,$); +#1441=IFCCLASSIFICATIONREFERENCE($,'21-06 10 80 60','Earth Movement Monitoring',#1437,$,$); +#1442=IFCCLASSIFICATIONREFERENCE($,'21-06 20','Facility Remediation',#1404,$,$); +#1443=IFCCLASSIFICATIONREFERENCE($,'21-06 20 10','Hazardous Materials Remediation',#1442,$,$); +#1444=IFCCLASSIFICATIONREFERENCE($,'21-06 20 10 10','Transportation and Disposal of Hazardous Materials',#1443,$,$); +#1445=IFCCLASSIFICATIONREFERENCE($,'21-06 20 10 20','Asbestos Remediation',#1443,$,$); +#1446=IFCCLASSIFICATIONREFERENCE($,'21-06 20 10 30','Lead Remediation',#1443,$,$); +#1447=IFCCLASSIFICATIONREFERENCE($,'21-06 20 10 40','Polychlorinate Biphenyl Remediation',#1443,$,$); +#1448=IFCCLASSIFICATIONREFERENCE($,'21-06 20 10 50','Mold Remediation',#1443,$,$); +#1449=IFCCLASSIFICATIONREFERENCE($,'21-06 30','Demolition',#1404,$,$); +#1450=IFCCLASSIFICATIONREFERENCE($,'21-06 30 10','Structure Demolition',#1449,$,$); +#1451=IFCCLASSIFICATIONREFERENCE($,'21-06 30 10 10','Building Demolition',#1450,$,$); +#1452=IFCCLASSIFICATIONREFERENCE($,'21-06 30 10 30','Tower Demolition',#1450,$,$); +#1453=IFCCLASSIFICATIONREFERENCE($,'21-06 30 10 50','Bridge Demolition',#1450,$,$); +#1454=IFCCLASSIFICATIONREFERENCE($,'21-06 30 10 70','Dam Demolition',#1450,$,$); +#1455=IFCCLASSIFICATIONREFERENCE($,'21-06 30 30','Selective Demolition',#1449,$,$); +#1456=IFCCLASSIFICATIONREFERENCE($,'21-06 30 30 10','Selective Building Demolition',#1455,$,$); +#1457=IFCCLASSIFICATIONREFERENCE($,'21-06 30 30 30','Selective Interior Demolition',#1455,$,$); +#1458=IFCCLASSIFICATIONREFERENCE($,'21-06 30 30 50','Selective Bridge Demolition',#1455,$,$); +#1459=IFCCLASSIFICATIONREFERENCE($,'21-06 30 30 70','Selective Historic Demolition',#1455,$,$); +#1460=IFCCLASSIFICATIONREFERENCE($,'21-06 30 50','Structure Moving',#1449,$,$); +#1461=IFCCLASSIFICATIONREFERENCE($,'21-06 30 50 10','Structure Relocation',#1460,$,$); +#1462=IFCCLASSIFICATIONREFERENCE($,'21-06 30 50 30','Structure Raising',#1460,$,$); +#1463=IFCCLASSIFICATIONREFERENCE($,'21-07 00 00','Sitework',#964,$,$); +#1464=IFCCLASSIFICATIONREFERENCE($,'21-07 10','Site Preparation',#1463,$,$); +#1465=IFCCLASSIFICATIONREFERENCE($,'21-07 10 10','Site Clearing',#1464,$,$); +#1466=IFCCLASSIFICATIONREFERENCE($,'21-07 10 10 10','Clearing and Grubbing',#1465,$,$); +#1467=IFCCLASSIFICATIONREFERENCE($,'21-07 10 10 30','Tree and Shrub Removal and Trimming',#1465,$,$); +#1468=IFCCLASSIFICATIONREFERENCE($,'21-07 10 10 50','Earth Stripping and Stockpiling',#1465,$,$); +#1469=IFCCLASSIFICATIONREFERENCE($,'21-07 10 20','Site Elements Demolition',#1464,$,$); +#1470=IFCCLASSIFICATIONREFERENCE($,'21-07 10 20 10','Utility Demolition',#1469,$,$); +#1471=IFCCLASSIFICATIONREFERENCE($,'21-07 10 20 30','Infrastructure Demolition',#1469,$,$); +#1472=IFCCLASSIFICATIONREFERENCE($,'21-07 10 20 50','Selective Site Demolition',#1469,$,$); +#1473=IFCCLASSIFICATIONREFERENCE($,'21-07 10 30','Site Element Relocations',#1464,$,$); +#1474=IFCCLASSIFICATIONREFERENCE($,'21-07 10 30 10','Utility Relocation',#1473,$,$); +#1475=IFCCLASSIFICATIONREFERENCE($,'21-07 10 50','Site Remediation',#1464,$,$); +#1476=IFCCLASSIFICATIONREFERENCE($,'21-07 10 50 10','Physical Decontamination',#1475,$,$); +#1477=IFCCLASSIFICATIONREFERENCE($,'21-07 10 50 15','Chemical Decontamination',#1475,$,$); +#1478=IFCCLASSIFICATIONREFERENCE($,'21-07 10 50 20','Thermal Decontamination',#1475,$,$); +#1479=IFCCLASSIFICATIONREFERENCE($,'21-07 10 50 25','Biological Decontamination',#1475,$,$); +#1480=IFCCLASSIFICATIONREFERENCE($,'21-07 10 50 30','Remediation Soil Stabilization',#1475,$,$); +#1481=IFCCLASSIFICATIONREFERENCE($,'21-07 10 50 40','Site Containment',#1475,$,$); +#1482=IFCCLASSIFICATIONREFERENCE($,'21-07 10 50 45','Sinkhole Remediation',#1475,$,$); +#1483=IFCCLASSIFICATIONREFERENCE($,'21-07 10 50 50','Hazardous Waste Drum Handling',#1475,$,$); +#1484=IFCCLASSIFICATIONREFERENCE($,'21-07 10 50 60','Contaminated Site Material Removal',#1475,$,$); +#1485=IFCCLASSIFICATIONREFERENCE($,'21-07 10 50 80','Water Remediation',#1475,$,$); +#1486=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70','Site Earthwork',#1464,$,$); +#1487=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70 10','Grading',#1486,$,$); +#1488=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70 20','Excavation and Fill',#1486,$,$); +#1489=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70 30','Embankments',#1486,$,$); +#1490=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70 35','Erosion and Sedimentation Controls',#1486,$,$); +#1491=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70 40','Soil Stabilization',#1486,$,$); +#1492=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70 45','Rock Stabilization',#1486,$,$); +#1493=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70 50','Soil Reinforcement',#1486,$,$); +#1494=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70 55','Slope Protection',#1486,$,$); +#1495=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70 60','Gabions',#1486,$,$); +#1496=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70 65','Riprap',#1486,$,$); +#1497=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70 70','Wetlands',#1486,$,$); +#1498=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70 80','Earth Dams',#1486,$,$); +#1499=IFCCLASSIFICATIONREFERENCE($,'21-07 10 70 90','Site Soil Treatment',#1486,$,$); +#1500=IFCCLASSIFICATIONREFERENCE($,'21-07 20','Site Improvements',#1463,$,$); +#1501=IFCCLASSIFICATIONREFERENCE($,'21-07 20 10','Roadways',#1500,$,$); +#1502=IFCCLASSIFICATIONREFERENCE($,'21-07 20 10 10','Roadway Pavement',#1501,$,$); +#1503=IFCCLASSIFICATIONREFERENCE($,'21-07 20 10 20','Roadway Curbs and Gutters',#1501,$,$); +#1504=IFCCLASSIFICATIONREFERENCE($,'21-07 20 10 40','Roadway Appurtenances',#1501,$,$); +#1505=IFCCLASSIFICATIONREFERENCE($,'21-07 20 10 70','Roadway Lighting',#1501,$,$); +#1506=IFCCLASSIFICATIONREFERENCE($,'21-07 20 10 80','Vehicle Fare Collection',#1501,$,$); +#1507=IFCCLASSIFICATIONREFERENCE($,'21-07 20 20','Parking Lots',#1500,$,$); +#1508=IFCCLASSIFICATIONREFERENCE($,'21-07 20 20 10','Parking Lot Pavement',#1507,$,$); +#1509=IFCCLASSIFICATIONREFERENCE($,'21-07 20 20 20','Parking Lot Curbs and Gutters',#1507,$,$); +#1510=IFCCLASSIFICATIONREFERENCE($,'21-07 20 20 40','Parking Lot Appurtenances',#1507,$,$); +#1511=IFCCLASSIFICATIONREFERENCE($,'21-07 20 20 70','Parking Lot Lighting',#1507,$,$); +#1512=IFCCLASSIFICATIONREFERENCE($,'21-07 20 20 80','Exterior Parking Control Equipment',#1507,$,$); +#1513=IFCCLASSIFICATIONREFERENCE($,'21-07 20 30','Pedestrian Plazas and Walkways',#1500,$,$); +#1514=IFCCLASSIFICATIONREFERENCE($,'21-07 20 30 10','Pedestrian Pavement',#1513,$,$); +#1515=IFCCLASSIFICATIONREFERENCE($,'21-07 20 30 20','Pedestrian Pavement Curbs and Gutters',#1513,$,$); +#1516=IFCCLASSIFICATIONREFERENCE($,'21-07 20 30 30','Exterior Steps and Ramps',#1513,$,$); +#1517=IFCCLASSIFICATIONREFERENCE($,'21-07 20 30 40','Pedestrian Pavement Appurtenances',#1513,$,$); +#1518=IFCCLASSIFICATIONREFERENCE($,'21-07 20 30 70','Plaza and Walkway Lighting',#1513,$,$); +#1519=IFCCLASSIFICATIONREFERENCE($,'21-07 20 30 80','Exterior Pedestrian Control Equipment',#1513,$,$); +#1520=IFCCLASSIFICATIONREFERENCE($,'21-07 20 40','Airfields',#1500,$,$); +#1521=IFCCLASSIFICATIONREFERENCE($,'21-07 20 40 10','Aviation Pavement',#1520,$,$); +#1522=IFCCLASSIFICATIONREFERENCE($,'21-07 20 40 20','Aviation Pavement Curbs and Gutters',#1520,$,$); +#1523=IFCCLASSIFICATIONREFERENCE($,'21-07 20 40 40','Aviation Pavement Appurtenances',#1520,$,$); +#1524=IFCCLASSIFICATIONREFERENCE($,'21-07 20 40 70','Airfield Lighting',#1520,$,$); +#1525=IFCCLASSIFICATIONREFERENCE($,'21-07 20 40 80','Airfield Signaling and Control Equipment',#1520,$,$); +#1526=IFCCLASSIFICATIONREFERENCE($,'21-07 20 50','Athletic, Recreational, and Playfield Areas',#1500,$,$); +#1527=IFCCLASSIFICATIONREFERENCE($,'21-07 20 50 10','Athletic Areas',#1526,$,$); +#1528=IFCCLASSIFICATIONREFERENCE($,'21-07 20 50 30','Recreational Areas',#1526,$,$); +#1529=IFCCLASSIFICATIONREFERENCE($,'21-07 20 50 50','Playfield Areas',#1526,$,$); +#1530=IFCCLASSIFICATIONREFERENCE($,'21-07 20 60','Site Development',#1500,$,$); +#1531=IFCCLASSIFICATIONREFERENCE($,'21-07 20 60 10','Exterior Fountains',#1530,$,$); +#1532=IFCCLASSIFICATIONREFERENCE($,'21-07 20 60 20','Fences and Gates',#1530,$,$); +#1533=IFCCLASSIFICATIONREFERENCE($,'21-07 20 60 25','Site Furnishings',#1530,$,$); +#1534=IFCCLASSIFICATIONREFERENCE($,'21-07 20 60 30','Exterior Signage',#1530,$,$); +#1535=IFCCLASSIFICATIONREFERENCE($,'21-07 20 60 35','Flagpoles',#1530,$,$); +#1536=IFCCLASSIFICATIONREFERENCE($,'21-07 20 60 40','Covers and Shelters',#1530,$,$); +#1537=IFCCLASSIFICATIONREFERENCE($,'21-07 20 60 45','Exterior Gas Lighting',#1530,$,$); +#1538=IFCCLASSIFICATIONREFERENCE($,'21-07 20 60 50','Site Equipment',#1530,$,$); +#1539=IFCCLASSIFICATIONREFERENCE($,'21-07 20 60 60','Retaining Walls',#1530,$,$); +#1540=IFCCLASSIFICATIONREFERENCE($,'21-07 20 60 70','Site Bridges',#1530,$,$); +#1541=IFCCLASSIFICATIONREFERENCE($,'21-07 20 60 80','Site Screening Devices',#1530,$,$); +#1542=IFCCLASSIFICATIONREFERENCE($,'21-07 20 60 85','Site Specialties',#1530,$,$); +#1543=IFCCLASSIFICATIONREFERENCE($,'21-07 20 80','Landscaping',#1500,$,$); +#1544=IFCCLASSIFICATIONREFERENCE($,'21-07 20 80 10','Planting Irrigation',#1543,$,$); +#1545=IFCCLASSIFICATIONREFERENCE($,'21-07 20 80 20','Turf and Grasses',#1543,$,$); +#1546=IFCCLASSIFICATIONREFERENCE($,'21-07 20 80 30','Plants',#1543,$,$); +#1547=IFCCLASSIFICATIONREFERENCE($,'21-07 20 80 50','Planting Accessories',#1543,$,$); +#1548=IFCCLASSIFICATIONREFERENCE($,'21-07 20 80 70','Landscape Lighting',#1543,$,$); +#1549=IFCCLASSIFICATIONREFERENCE($,'21-07 20 80 80','Landscaping Activities',#1543,$,$); +#1550=IFCCLASSIFICATIONREFERENCE($,'21-07 30','Liquid and Gas Site Utilities',#1463,$,$); +#1551=IFCCLASSIFICATIONREFERENCE($,'21-07 30 10','Water Utilities',#1550,$,$); +#1552=IFCCLASSIFICATIONREFERENCE($,'21-07 30 10 10','Site Domestic Water Distribution',#1551,$,$); +#1553=IFCCLASSIFICATIONREFERENCE($,'21-07 30 10 30','Site Fire Protection Water Distribution',#1551,$,$); +#1554=IFCCLASSIFICATIONREFERENCE($,'21-07 30 10 50','Site Irrigation Water Distribution',#1551,$,$); +#1555=IFCCLASSIFICATIONREFERENCE($,'21-07 30 20','Sanitary Sewerage Utilities',#1550,$,$); +#1556=IFCCLASSIFICATIONREFERENCE($,'21-07 30 20 10','Sanitary Sewerage Utility Connection',#1555,$,$); +#1557=IFCCLASSIFICATIONREFERENCE($,'21-07 30 20 20','Sanitary Sewerage Piping',#1555,$,$); +#1558=IFCCLASSIFICATIONREFERENCE($,'21-07 30 20 40','Utility Septic Tanks',#1555,$,$); +#1559=IFCCLASSIFICATIONREFERENCE($,'21-07 30 20 50','Sanitary Sewerage Structures',#1555,$,$); +#1560=IFCCLASSIFICATIONREFERENCE($,'21-07 30 20 60','Sanitary Sewerage Lagoons',#1555,$,$); +#1561=IFCCLASSIFICATIONREFERENCE($,'21-07 30 30','Storm Drainage Utilities',#1550,$,$); +#1562=IFCCLASSIFICATIONREFERENCE($,'21-07 30 30 10','Storm Drainage Utility Connection',#1561,$,$); +#1563=IFCCLASSIFICATIONREFERENCE($,'21-07 30 30 20','Storm Drainage Piping',#1561,$,$); +#1564=IFCCLASSIFICATIONREFERENCE($,'21-07 30 30 30','Culverts',#1561,$,$); +#1565=IFCCLASSIFICATIONREFERENCE($,'21-07 30 30 40','Site Storm Water Drains',#1561,$,$); +#1566=IFCCLASSIFICATIONREFERENCE($,'21-07 30 30 50','Storm Drainage Pumps',#1561,$,$); +#1567=IFCCLASSIFICATIONREFERENCE($,'21-07 30 30 60','Site Subdrainage',#1561,$,$); +#1568=IFCCLASSIFICATIONREFERENCE($,'21-07 30 30 70','Storm Drainage Ponds and Reservoirs',#1561,$,$); +#1569=IFCCLASSIFICATIONREFERENCE($,'21-07 30 50','Site Energy Distribution',#1550,$,$); +#1570=IFCCLASSIFICATIONREFERENCE($,'21-07 30 50 10','Site Hydronic Heating Distribution',#1569,$,$); +#1571=IFCCLASSIFICATIONREFERENCE($,'21-07 30 50 20','Site Steam Energy Distribution',#1569,$,$); +#1572=IFCCLASSIFICATIONREFERENCE($,'21-07 30 50 40','Site Hydronic Cooling Distribution',#1569,$,$); +#1573=IFCCLASSIFICATIONREFERENCE($,'21-07 30 60','Site Fuel Distribution',#1550,$,$); +#1574=IFCCLASSIFICATIONREFERENCE($,'21-07 30 60 10','Site Gas Distribution',#1573,$,$); +#1575=IFCCLASSIFICATIONREFERENCE($,'21-07 30 60 20','Site Fuel-Oil Distribution',#1573,$,$); +#1576=IFCCLASSIFICATIONREFERENCE($,'21-07 30 60 30','Site Gasoline Distribution',#1573,$,$); +#1577=IFCCLASSIFICATIONREFERENCE($,'21-07 30 60 40','Site Diesel Fuel Distribution',#1573,$,$); +#1578=IFCCLASSIFICATIONREFERENCE($,'21-07 30 60 60','Site Aviation Fuel Distribution',#1573,$,$); +#1579=IFCCLASSIFICATIONREFERENCE($,'21-07 30 90','Liquid and Gas Site Utilities Supplementary Components',#1550,$,$); +#1580=IFCCLASSIFICATIONREFERENCE($,'21-07 30 90 10','Supplementary Components',#1579,$,$); +#1581=IFCCLASSIFICATIONREFERENCE($,'21-07 40','Electrical Site Improvements',#1463,$,$); +#1582=IFCCLASSIFICATIONREFERENCE($,'21-07 40 10','Site Electric Distribution Systems',#1581,$,$); +#1583=IFCCLASSIFICATIONREFERENCE($,'21-07 40 10 10','Electrical Utility Services',#1582,$,$); +#1584=IFCCLASSIFICATIONREFERENCE($,'21-07 40 10 20','Electric Transmission and Distribution',#1582,$,$); +#1585=IFCCLASSIFICATIONREFERENCE($,'21-07 40 10 30','Electrical Substations',#1582,$,$); +#1586=IFCCLASSIFICATIONREFERENCE($,'21-07 40 10 40','Electrical Transformers',#1582,$,$); +#1587=IFCCLASSIFICATIONREFERENCE($,'21-07 40 10 50','Electrical Switchgear and Protection Devices',#1582,$,$); +#1588=IFCCLASSIFICATIONREFERENCE($,'21-07 40 10 70','Site Grounding',#1582,$,$); +#1589=IFCCLASSIFICATIONREFERENCE($,'21-07 40 10 90','Electrical Distribution System Instrumentation and Controls',#1582,$,$); +#1590=IFCCLASSIFICATIONREFERENCE($,'21-07 40 50','Site Lighting',#1581,$,$); +#1591=IFCCLASSIFICATIONREFERENCE($,'21-07 40 50 10','Area Lighting',#1590,$,$); +#1592=IFCCLASSIFICATIONREFERENCE($,'21-07 40 50 20','Flood Lighting',#1590,$,$); +#1593=IFCCLASSIFICATIONREFERENCE($,'21-07 40 50 50','Building Illumination',#1590,$,$); +#1594=IFCCLASSIFICATIONREFERENCE($,'21-07 40 50 90','Exterior Lighting Supplementary Components',#1590,$,$); +#1595=IFCCLASSIFICATIONREFERENCE($,'21-07 50','Site Communications',#1463,$,$); +#1596=IFCCLASSIFICATIONREFERENCE($,'21-07 50 10','Site Communications Systems',#1595,$,$); +#1597=IFCCLASSIFICATIONREFERENCE($,'21-07 50 10 10','Site Communications Structures',#1596,$,$); +#1598=IFCCLASSIFICATIONREFERENCE($,'21-07 50 10 30','Site Communications Distribution',#1596,$,$); +#1599=IFCCLASSIFICATIONREFERENCE($,'21-07 50 10 50','Wireless Communications Distribution',#1596,$,$); +#1600=IFCCLASSIFICATIONREFERENCE($,'21-07 90','Miscellaneous Site Construction',#1463,$,$); +#1601=IFCCLASSIFICATIONREFERENCE($,'21-07 90 10','Tunnels',#1600,$,$); +#1602=IFCCLASSIFICATIONREFERENCE($,'21-07 90 10 10','Vehicular Tunnels',#1601,$,$); +#1603=IFCCLASSIFICATIONREFERENCE($,'21-07 90 10 20','Pedestrian Tunnels',#1601,$,$); +#1604=IFCCLASSIFICATIONREFERENCE($,'21-07 90 10 40','Service Tunnels',#1601,$,$); +#1605=IFCCLASSIFICATIONREFERENCE($,'21-07 90 10 90','Tunnel Construction Related Activities',#1601,$,$); +#1606=IFCCLASSIFICATIONREFERENCE($,'Table 23 - Products',$,#2,'Assigns construction product classes to building elements based on this OmniClass (edition 2012) specification.\X2\000A000A\X0\''Apply'' creates a Classification Reference for selected IFC entity (IfcElement, IfcTypeProduct (except IfcSpaceType), IfcGroup and IfcSystem), using OmniClass-required attributes derived from the item that you choose in the following list.\X2\000A00090009\X0\',$); +#1607=IFCCLASSIFICATIONREFERENCE($,'23-11 00 00','Site Products',#1606,$,$); +#1608=IFCCLASSIFICATIONREFERENCE($,'23-11 11 00','Ground Anchorages',#1607,$,$); +#1609=IFCCLASSIFICATIONREFERENCE($,'23-11 11 11','Retaining Stabilizing Ground Anchors',#1608,$,$); +#1610=IFCCLASSIFICATIONREFERENCE($,'23-11 11 11 11','Retaining Stabilizing Ground Components',#1609,$,$); +#1611=IFCCLASSIFICATIONREFERENCE($,'23-11 11 11 11 11','Stabilizing Ground Anchor Heads',#1610,$,$); +#1612=IFCCLASSIFICATIONREFERENCE($,'23-11 11 11 11 13','Stabilizing Ground Tendons',#1610,$,$); +#1613=IFCCLASSIFICATIONREFERENCE($,'23-11 11 11 13','Stabilizing Ground Grouted Anchors',#1609,$,$); +#1614=IFCCLASSIFICATIONREFERENCE($,'23-11 11 11 15','Stabilizing Ground Plate Anchors',#1609,$,$); +#1615=IFCCLASSIFICATIONREFERENCE($,'23-11 11 11 17','Stabilizing Ground Rock Bolts',#1609,$,$); +#1616=IFCCLASSIFICATIONREFERENCE($,'23-11 11 11 19','Stabilizing Ground Rock Anchors',#1609,$,$); +#1617=IFCCLASSIFICATIONREFERENCE($,'23-11 11 11 21','Stabilizing Ground Anchor Tiebacks',#1609,$,$); +#1618=IFCCLASSIFICATIONREFERENCE($,'23-11 11 13','Earth Reinforcement Anchors',#1608,$,$); +#1619=IFCCLASSIFICATIONREFERENCE($,'23-11 11 13 11','Earth Reinforcement Soil Nails',#1618,$,$); +#1620=IFCCLASSIFICATIONREFERENCE($,'23-11 13 00','Ground Improvement Products',#1607,$,$); +#1621=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11','Soil Stabilization Products',#1620,$,$); +#1622=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 11','Soil Stabilization Injectable Chemicals',#1621,$,$); +#1623=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 13','Soil Stabilization Pressure Grouting',#1621,$,$); +#1624=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 15','Ground Freezing Soil Stabilization',#1621,$,$); +#1625=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 17','Soil Stabilization Fills',#1621,$,$); +#1626=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 17 11','Soil Stabilization Fill Blocks',#1625,$,$); +#1627=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 17 13','Soil Stabilization Compressible Fill',#1625,$,$); +#1628=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 19','Other Soil Stabilizations',#1621,$,$); +#1629=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 21','Piped Field Drainage',#1621,$,$); +#1630=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 21 11','Field Drainage Land Drainage Pipes',#1629,$,$); +#1631=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 23','Field Drainage Blocks',#1621,$,$); +#1632=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 25','Field Drainage Geocomposite Drains',#1621,$,$); +#1633=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 25 11','Field Drainage Geocomposite Edge Drains',#1632,$,$); +#1634=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 25 13','Field Drainage Geocomposite In Place Wall Drains',#1632,$,$); +#1635=IFCCLASSIFICATIONREFERENCE($,'23-11 13 11 27','Geotextile Subsurface Drainage Filtration',#1621,$,$); +#1636=IFCCLASSIFICATIONREFERENCE($,'23-11 15 00','Sheeting and Revetments',#1607,$,$); +#1637=IFCCLASSIFICATIONREFERENCE($,'23-11 15 11','Sheeting Geosynthetics',#1636,$,$); +#1638=IFCCLASSIFICATIONREFERENCE($,'23-11 15 11 11','Sheeting Geotextiles',#1637,$,$); +#1639=IFCCLASSIFICATIONREFERENCE($,'23-11 15 11 13','Sheeting Geogrids',#1637,$,$); +#1640=IFCCLASSIFICATIONREFERENCE($,'23-11 15 11 15','Sheeting Geomembranes',#1637,$,$); +#1641=IFCCLASSIFICATIONREFERENCE($,'23-11 15 11 17','Sheeting Geocomposites',#1637,$,$); +#1642=IFCCLASSIFICATIONREFERENCE($,'23-11 15 11 19','Sheeting Mulch Control Netting',#1637,$,$); +#1643=IFCCLASSIFICATIONREFERENCE($,'23-11 15 11 21','Sheeting Synthetic Erosion Controls',#1637,$,$); +#1644=IFCCLASSIFICATIONREFERENCE($,'23-11 15 11 23','Sheeting Re vegetation Mats',#1637,$,$); +#1645=IFCCLASSIFICATIONREFERENCE($,'23-11 15 11 25','Sheeting Turf Reinforcement Mats',#1637,$,$); +#1646=IFCCLASSIFICATIONREFERENCE($,'23-11 15 13','Revetments',#1636,$,$); +#1647=IFCCLASSIFICATIONREFERENCE($,'23-11 15 13 11','Revetment Soil Blankets',#1646,$,$); +#1648=IFCCLASSIFICATIONREFERENCE($,'23-11 15 13 13','Pool Revetments',#1646,$,$); +#1649=IFCCLASSIFICATIONREFERENCE($,'23-11 15 13 15','Trench Revetments',#1646,$,$); +#1650=IFCCLASSIFICATIONREFERENCE($,'23-11 15 13 17','Revetment Rock Linings',#1646,$,$); +#1651=IFCCLASSIFICATIONREFERENCE($,'23-11 15 13 19','Revetment Ripraps',#1646,$,$); +#1652=IFCCLASSIFICATIONREFERENCE($,'23-11 17 00','Retention Structures',#1607,$,$); +#1653=IFCCLASSIFICATIONREFERENCE($,'23-11 17 11','Sheet Piles',#1652,$,$); +#1654=IFCCLASSIFICATIONREFERENCE($,'23-11 17 13','Retaining Walls',#1652,$,$); +#1655=IFCCLASSIFICATIONREFERENCE($,'23-11 17 13 11','Retaining Diaphragm Walls',#1654,$,$); +#1656=IFCCLASSIFICATIONREFERENCE($,'23-11 17 13 11 11','Retaining Slurry Wall Membranes',#1655,$,$); +#1657=IFCCLASSIFICATIONREFERENCE($,'23-11 17 13 13','Continuous Retaining Walls',#1654,$,$); +#1658=IFCCLASSIFICATIONREFERENCE($,'23-11 17 13 15','Retaining Crib Walls',#1654,$,$); +#1659=IFCCLASSIFICATIONREFERENCE($,'23-11 17 15','Gabions',#1652,$,$); +#1660=IFCCLASSIFICATIONREFERENCE($,'23-11 17 17','Fascines',#1652,$,$); +#1661=IFCCLASSIFICATIONREFERENCE($,'23-11 19 00','Slide and Avalanche Protection',#1607,$,$); +#1662=IFCCLASSIFICATIONREFERENCE($,'23-11 19 11','Bolt Down Snow Fences',#1661,$,$); +#1663=IFCCLASSIFICATIONREFERENCE($,'23-11 19 13','Clamp on Equipment',#1661,$,$); +#1664=IFCCLASSIFICATIONREFERENCE($,'23-11 21 00','Pavements',#1607,$,$); +#1665=IFCCLASSIFICATIONREFERENCE($,'23-11 21 11','Porous Paving',#1664,$,$); +#1666=IFCCLASSIFICATIONREFERENCE($,'23-11 21 13','Roadways',#1664,$,$); +#1667=IFCCLASSIFICATIONREFERENCE($,'23-11 21 13 11','Portable Roadways',#1666,$,$); +#1668=IFCCLASSIFICATIONREFERENCE($,'23-11 21 13 13','Roadway Surfacing',#1666,$,$); +#1669=IFCCLASSIFICATIONREFERENCE($,'23-11 21 13 13 11','Roadway Antiskid Texturing',#1668,$,$); +#1670=IFCCLASSIFICATIONREFERENCE($,'23-11 21 13 15','Detectable Warning Surfaces for Roadways',#1666,$,$); +#1671=IFCCLASSIFICATIONREFERENCE($,'23-11 21 13 15 11','Crosswalks',#1670,$,$); +#1672=IFCCLASSIFICATIONREFERENCE($,'23-11 21 13 15 13','Warning Tiles',#1670,$,$); +#1673=IFCCLASSIFICATIONREFERENCE($,'23-11 21 15','Runways',#1664,$,$); +#1674=IFCCLASSIFICATIONREFERENCE($,'23-11 21 15 11','Portable Runway',#1673,$,$); +#1675=IFCCLASSIFICATIONREFERENCE($,'23-11 21 15 13','Helicopter Landing Pads',#1673,$,$); +#1676=IFCCLASSIFICATIONREFERENCE($,'23-11 21 15 15','Runway Surfacing',#1673,$,$); +#1677=IFCCLASSIFICATIONREFERENCE($,'23-11 21 15 15 11','Runway Antiskid Texturing',#1676,$,$); +#1678=IFCCLASSIFICATIONREFERENCE($,'23-11 21 17','Paving Blocks',#1664,$,$); +#1679=IFCCLASSIFICATIONREFERENCE($,'23-11 21 17 11','Unit Pavers',#1678,$,$); +#1680=IFCCLASSIFICATIONREFERENCE($,'23-11 21 17 11 11','Asphalt Block Pavers',#1679,$,$); +#1681=IFCCLASSIFICATIONREFERENCE($,'23-11 21 17 11 13','Brick Pavers',#1679,$,$); +#1682=IFCCLASSIFICATIONREFERENCE($,'23-11 21 17 11 15','Interlocking Precast Concrete Pavers',#1679,$,$); +#1683=IFCCLASSIFICATIONREFERENCE($,'23-11 21 17 11 17','Precast Concrete Pavers',#1679,$,$); +#1684=IFCCLASSIFICATIONREFERENCE($,'23-11 21 17 11 19','Pressed Pavers',#1679,$,$); +#1685=IFCCLASSIFICATIONREFERENCE($,'23-11 21 17 11 21','Stone Pavers',#1679,$,$); +#1686=IFCCLASSIFICATIONREFERENCE($,'23-11 21 19','Pavement Slabs',#1664,$,$); +#1687=IFCCLASSIFICATIONREFERENCE($,'23-11 21 21','Pavement Drainage',#1664,$,$); +#1688=IFCCLASSIFICATIONREFERENCE($,'23-11 21 21 11','Culverts',#1687,$,$); +#1689=IFCCLASSIFICATIONREFERENCE($,'23-11 21 21 11 11','Pipe Culverts',#1688,$,$); +#1690=IFCCLASSIFICATIONREFERENCE($,'23-11 21 21 11 11 11','Metal Pipe Arch Culverts',#1689,$,$); +#1691=IFCCLASSIFICATIONREFERENCE($,'23-11 21 21 11 13','Concrete Culverts',#1688,$,$); +#1692=IFCCLASSIFICATIONREFERENCE($,'23-11 21 21 11 13 11','Concrete Arch Buried Bridge Culverts',#1691,$,$); +#1693=IFCCLASSIFICATIONREFERENCE($,'23-11 21 21 11 13 13','Concrete Arch Culverts',#1691,$,$); +#1694=IFCCLASSIFICATIONREFERENCE($,'23-11 21 21 11 13 15','Concrete Box Culverts',#1691,$,$); +#1695=IFCCLASSIFICATIONREFERENCE($,'23-11 21 21 11 13 17','Concrete Rigid Frame Culverts',#1691,$,$); +#1696=IFCCLASSIFICATIONREFERENCE($,'23-11 21 21 13','Catch Basins',#1687,$,$); +#1697=IFCCLASSIFICATIONREFERENCE($,'23-11 21 21 15','Channels',#1687,$,$); +#1698=IFCCLASSIFICATIONREFERENCE($,'23-11 21 21 17','Cleanouts',#1687,$,$); +#1699=IFCCLASSIFICATIONREFERENCE($,'23-11 23 00','Parking Controls',#1607,$,$); +#1700=IFCCLASSIFICATIONREFERENCE($,'23-11 23 11','Parking Meters',#1699,$,$); +#1701=IFCCLASSIFICATIONREFERENCE($,'23-11 23 13','Parking Ticket Dispensers',#1699,$,$); +#1702=IFCCLASSIFICATIONREFERENCE($,'23-11 23 15','Parking Coin Machine Units',#1699,$,$); +#1703=IFCCLASSIFICATIONREFERENCE($,'23-11 23 17','Parking Key and Card Control Units',#1699,$,$); +#1704=IFCCLASSIFICATIONREFERENCE($,'23-11 23 19','Parking Gates',#1699,$,$); +#1705=IFCCLASSIFICATIONREFERENCE($,'23-11 23 21','Parking Dividers',#1699,$,$); +#1706=IFCCLASSIFICATIONREFERENCE($,'23-11 23 23','Parking Signs',#1699,$,$); +#1707=IFCCLASSIFICATIONREFERENCE($,'23-11 23 23 11','Handicap Parking Signs',#1706,$,$); +#1708=IFCCLASSIFICATIONREFERENCE($,'23-11 23 23 13','Parking Time Zone Signs',#1706,$,$); +#1709=IFCCLASSIFICATIONREFERENCE($,'23-11 23 23 15','Parking Tow Away Signs',#1706,$,$); +#1710=IFCCLASSIFICATIONREFERENCE($,'23-11 25 00','Site Barrier Products',#1607,$,$); +#1711=IFCCLASSIFICATIONREFERENCE($,'23-11 25 11','Perimeter Entry Devices',#1710,$,$); +#1712=IFCCLASSIFICATIONREFERENCE($,'23-11 25 11 11','Anti Ram Wedge Barriers',#1711,$,$); +#1713=IFCCLASSIFICATIONREFERENCE($,'23-11 25 13','Perimeter Walls',#1710,$,$); +#1714=IFCCLASSIFICATIONREFERENCE($,'23-11 25 13 11','Precast Perimeter Concrete Panel Perimeter Walls',#1713,$,$); +#1715=IFCCLASSIFICATIONREFERENCE($,'23-11 25 13 13','Precast Perimeter Post Perimeter Walls',#1713,$,$); +#1716=IFCCLASSIFICATIONREFERENCE($,'23-11 25 15','Perimeter Gates',#1710,$,$); +#1717=IFCCLASSIFICATIONREFERENCE($,'23-11 25 15 11','Drop Arm Gates',#1716,$,$); +#1718=IFCCLASSIFICATIONREFERENCE($,'23-11 25 15 11 11','Anti Ram Drop Arm Gates',#1717,$,$); +#1719=IFCCLASSIFICATIONREFERENCE($,'23-11 25 15 13','Rolling Gates',#1716,$,$); +#1720=IFCCLASSIFICATIONREFERENCE($,'23-11 25 15 15','Sliding Gates',#1716,$,$); +#1721=IFCCLASSIFICATIONREFERENCE($,'23-11 25 15 15 11','Anti Ram Sliding Gates',#1720,$,$); +#1722=IFCCLASSIFICATIONREFERENCE($,'23-11 25 15 15 13','Anti Climb Sliding Gates',#1720,$,$); +#1723=IFCCLASSIFICATIONREFERENCE($,'23-11 25 15 17','Swinging Gates',#1716,$,$); +#1724=IFCCLASSIFICATIONREFERENCE($,'23-11 25 15 19','Folding Gates',#1716,$,$); +#1725=IFCCLASSIFICATIONREFERENCE($,'23-11 25 17','Gate Hardware',#1710,$,$); +#1726=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19','Fences',#1710,$,$); +#1727=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 11','Barbed Wire Fences',#1726,$,$); +#1728=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 13','Concertina Wire Fences',#1726,$,$); +#1729=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 15','Composite Fences',#1726,$,$); +#1730=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 17','Ornamental Metal Fences',#1726,$,$); +#1731=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 19','Chain Link Metal Fences',#1726,$,$); +#1732=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 21','Panel Fences',#1726,$,$); +#1733=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 23','Plastic Fences',#1726,$,$); +#1734=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 25','Post Fences',#1726,$,$); +#1735=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 27','Rail Fences',#1726,$,$); +#1736=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 29','Razor Wire Fences',#1726,$,$); +#1737=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 31','Wood Fences',#1726,$,$); +#1738=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 33','Fencing Fabrics',#1726,$,$); +#1739=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 35','Fencing Accessories',#1726,$,$); +#1740=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 35 11','Barbed Wire',#1739,$,$); +#1741=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 35 13','Concertina Wire',#1739,$,$); +#1742=IFCCLASSIFICATIONREFERENCE($,'23-11 25 19 35 15','Fence Posts',#1739,$,$); +#1743=IFCCLASSIFICATIONREFERENCE($,'23-11 27 00','Landscaping',#1607,$,$); +#1744=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11','Plant Maintenance and Preparation Products',#1743,$,$); +#1745=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 11','Topsoil',#1744,$,$); +#1746=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 11 11','Loam',#1745,$,$); +#1747=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 11 13','Peat Soil',#1745,$,$); +#1748=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 13','Soil Fertilizers',#1744,$,$); +#1749=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 15','Soil Herbicides',#1744,$,$); +#1750=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 15 11','Combined Soil Fertilizer and Herbicides',#1749,$,$); +#1751=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 17','Mulch',#1744,$,$); +#1752=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 19','Soil Mats',#1744,$,$); +#1753=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 21','Plant Netting',#1744,$,$); +#1754=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 23','Landscaping Stakes',#1744,$,$); +#1755=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 25','Landscaping Blankets',#1744,$,$); +#1756=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 27','Landscaping Ground Covers',#1744,$,$); +#1757=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 29','Landscaping Forms',#1744,$,$); +#1758=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 31','Landscaping Stabilizers',#1744,$,$); +#1759=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 33','Lime',#1744,$,$); +#1760=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 35','Mowing Equipment',#1744,$,$); +#1761=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 35 11','Lawnmowers',#1760,$,$); +#1762=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 35 13','Garden Tractors',#1760,$,$); +#1763=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 37','Pruning Equipment',#1744,$,$); +#1764=IFCCLASSIFICATIONREFERENCE($,'23-11 27 11 39','Watering Equipment',#1744,$,$); +#1765=IFCCLASSIFICATIONREFERENCE($,'23-11 27 13','Planting Accessories',#1743,$,$); +#1766=IFCCLASSIFICATIONREFERENCE($,'23-11 27 13 11','Landscaping Edging',#1765,$,$); +#1767=IFCCLASSIFICATIONREFERENCE($,'23-11 27 13 13','Landscape Timbers',#1765,$,$); +#1768=IFCCLASSIFICATIONREFERENCE($,'23-11 27 13 15','Landscape Stone',#1765,$,$); +#1769=IFCCLASSIFICATIONREFERENCE($,'23-11 27 13 15 11','Boulders',#1768,$,$); +#1770=IFCCLASSIFICATIONREFERENCE($,'23-11 27 13 17','Planters',#1765,$,$); +#1771=IFCCLASSIFICATIONREFERENCE($,'23-11 27 13 19','Tree Grates',#1765,$,$); +#1772=IFCCLASSIFICATIONREFERENCE($,'23-11 27 13 21','Tree Grids',#1765,$,$); +#1773=IFCCLASSIFICATIONREFERENCE($,'23-11 27 13 23','Tree Guards',#1765,$,$); +#1774=IFCCLASSIFICATIONREFERENCE($,'23-11 27 13 25','Plant Tubs',#1765,$,$); +#1775=IFCCLASSIFICATIONREFERENCE($,'23-11 27 15','Irrigation Equipment',#1743,$,$); +#1776=IFCCLASSIFICATIONREFERENCE($,'23-11 27 15 11','Irrigation Sprinklers',#1775,$,$); +#1777=IFCCLASSIFICATIONREFERENCE($,'23-11 27 15 11 11','Installed Sprinkler Heads',#1776,$,$); +#1778=IFCCLASSIFICATIONREFERENCE($,'23-11 27 15 11 13','Portable Lawn Sprinklers',#1776,$,$); +#1779=IFCCLASSIFICATIONREFERENCE($,'23-11 27 15 13','Irrigation Hoses',#1775,$,$); +#1780=IFCCLASSIFICATIONREFERENCE($,'23-11 27 15 13 11','Irrigation Weep Hoses',#1779,$,$); +#1781=IFCCLASSIFICATIONREFERENCE($,'23-11 27 17','Lawns and Grasses',#1743,$,$); +#1782=IFCCLASSIFICATIONREFERENCE($,'23-11 27 17 11','Hydro Mulch',#1781,$,$); +#1783=IFCCLASSIFICATIONREFERENCE($,'23-11 27 17 13','Grass Plugs',#1781,$,$); +#1784=IFCCLASSIFICATIONREFERENCE($,'23-11 27 17 15','Grass Seeds and Soil Supplements',#1781,$,$); +#1785=IFCCLASSIFICATIONREFERENCE($,'23-11 27 17 17','Sod',#1781,$,$); +#1786=IFCCLASSIFICATIONREFERENCE($,'23-11 27 19','Plants',#1743,$,$); +#1787=IFCCLASSIFICATIONREFERENCE($,'23-11 27 19 11','Shrubs',#1786,$,$); +#1788=IFCCLASSIFICATIONREFERENCE($,'23-11 27 19 13','Trees',#1786,$,$); +#1789=IFCCLASSIFICATIONREFERENCE($,'23-11 27 19 15','Plants',#1786,$,$); +#1790=IFCCLASSIFICATIONREFERENCE($,'23-11 27 19 17','Plant Bulbs',#1786,$,$); +#1791=IFCCLASSIFICATIONREFERENCE($,'23-11 27 19 19','Floral Plant',#1786,$,$); +#1792=IFCCLASSIFICATIONREFERENCE($,'23-11 27 19 21','Non Flowering Plant',#1786,$,$); +#1793=IFCCLASSIFICATIONREFERENCE($,'23-11 27 21','Pond Equipment',#1743,$,$); +#1794=IFCCLASSIFICATIONREFERENCE($,'23-11 27 21 11','Pond Liners',#1793,$,$); +#1795=IFCCLASSIFICATIONREFERENCE($,'23-11 27 21 13','Pond Filters',#1793,$,$); +#1796=IFCCLASSIFICATIONREFERENCE($,'23-11 29 00','Site Furnishings',#1607,$,$); +#1797=IFCCLASSIFICATIONREFERENCE($,'23-11 29 11','Bicycle Racks and Shelters',#1796,$,$); +#1798=IFCCLASSIFICATIONREFERENCE($,'23-11 29 11 11','Bicycle Racks',#1797,$,$); +#1799=IFCCLASSIFICATIONREFERENCE($,'23-11 29 11 13','Bicycle Shelters',#1797,$,$); +#1800=IFCCLASSIFICATIONREFERENCE($,'23-11 29 11 15','Bicycle Lockers',#1797,$,$); +#1801=IFCCLASSIFICATIONREFERENCE($,'23-11 29 13','Exterior Seating',#1796,$,$); +#1802=IFCCLASSIFICATIONREFERENCE($,'23-11 29 13 11','Exterior Benches',#1801,$,$); +#1803=IFCCLASSIFICATIONREFERENCE($,'23-11 29 13 13','Exterior Chairs',#1801,$,$); +#1804=IFCCLASSIFICATIONREFERENCE($,'23-11 29 15','Exterior Tables',#1796,$,$); +#1805=IFCCLASSIFICATIONREFERENCE($,'23-11 29 17','Patio Furniture',#1796,$,$); +#1806=IFCCLASSIFICATIONREFERENCE($,'23-11 29 17 11','Patio Seating',#1805,$,$); +#1807=IFCCLASSIFICATIONREFERENCE($,'23-11 29 17 11 11','Patio Chairs',#1806,$,$); +#1808=IFCCLASSIFICATIONREFERENCE($,'23-11 29 17 11 13','Patio Benches',#1806,$,$); +#1809=IFCCLASSIFICATIONREFERENCE($,'23-11 29 17 11 15','Patio Chaise Lounges',#1806,$,$); +#1810=IFCCLASSIFICATIONREFERENCE($,'23-11 29 17 11 17','Patio Sofas',#1806,$,$); +#1811=IFCCLASSIFICATIONREFERENCE($,'23-11 29 17 13','Patio Tables',#1805,$,$); +#1812=IFCCLASSIFICATIONREFERENCE($,'23-11 29 17 13 11','Patio Dining Tables',#1811,$,$); +#1813=IFCCLASSIFICATIONREFERENCE($,'23-11 29 17 13 13','Patio Sofa Tables',#1811,$,$); +#1814=IFCCLASSIFICATIONREFERENCE($,'23-11 29 19','Exterior Trash Receptacles',#1796,$,$); +#1815=IFCCLASSIFICATIONREFERENCE($,'23-11 29 19 11','Exterior Wood Trash Receptacles',#1814,$,$); +#1816=IFCCLASSIFICATIONREFERENCE($,'23-11 29 19 13','Exterior Concrete Trash Receptacles',#1814,$,$); +#1817=IFCCLASSIFICATIONREFERENCE($,'23-11 29 19 15','Exterior Metal Trash Receptacles',#1814,$,$); +#1818=IFCCLASSIFICATIONREFERENCE($,'23-11 29 21','Exterior Specialties',#1796,$,$); +#1819=IFCCLASSIFICATIONREFERENCE($,'23-11 29 21 11','Sundials',#1818,$,$); +#1820=IFCCLASSIFICATIONREFERENCE($,'23-11 29 21 13','Garden Ornaments',#1818,$,$); +#1821=IFCCLASSIFICATIONREFERENCE($,'23-11 29 21 15','Bird Houses',#1818,$,$); +#1822=IFCCLASSIFICATIONREFERENCE($,'23-11 29 21 17','Bird Feeders',#1818,$,$); +#1823=IFCCLASSIFICATIONREFERENCE($,'23-11 29 21 19','Bird Baths',#1818,$,$); +#1824=IFCCLASSIFICATIONREFERENCE($,'23-11 29 23','Exterior Storage Structures',#1796,$,$); +#1825=IFCCLASSIFICATIONREFERENCE($,'23-11 29 23 11','Storage Sheds',#1824,$,$); +#1826=IFCCLASSIFICATIONREFERENCE($,'23-11 29 23 13','Barns',#1824,$,$); +#1827=IFCCLASSIFICATIONREFERENCE($,'23-11 29 25','Flagpoles',#1796,$,$); +#1828=IFCCLASSIFICATIONREFERENCE($,'23-11 29 25 11','Automatic Flagpoles',#1827,$,$); +#1829=IFCCLASSIFICATIONREFERENCE($,'23-11 29 25 13','Ground Set Flagpoles',#1827,$,$); +#1830=IFCCLASSIFICATIONREFERENCE($,'23-11 29 25 15','Nautical Flagpoles',#1827,$,$); +#1831=IFCCLASSIFICATIONREFERENCE($,'23-11 29 25 17','Wall Mounted Flagpoles',#1827,$,$); +#1832=IFCCLASSIFICATIONREFERENCE($,'23-11 29 27','Exterior Fountains',#1796,$,$); +#1833=IFCCLASSIFICATIONREFERENCE($,'23-11 29 27 11','Exterior Ornamental Fountains',#1832,$,$); +#1834=IFCCLASSIFICATIONREFERENCE($,'23-11 29 29','Memorials and Statuary',#1796,$,$); +#1835=IFCCLASSIFICATIONREFERENCE($,'23-11 29 31','Monuments',#1796,$,$); +#1836=IFCCLASSIFICATIONREFERENCE($,'23-11 29 33','Exterior Directional Signs',#1796,$,$); +#1837=IFCCLASSIFICATIONREFERENCE($,'23-11 29 33 11','Finger Post Signs',#1836,$,$); +#1838=IFCCLASSIFICATIONREFERENCE($,'23-11 29 33 13','Street Nameplates',#1836,$,$); +#1839=IFCCLASSIFICATIONREFERENCE($,'23-11 29 33 15','Illuminated Directional Signs',#1836,$,$); +#1840=IFCCLASSIFICATIONREFERENCE($,'23-11 29 33 17','Directional Sign Markers',#1836,$,$); +#1841=IFCCLASSIFICATIONREFERENCE($,'23-11 29 35','Bollards',#1796,$,$); +#1842=IFCCLASSIFICATIONREFERENCE($,'23-11 29 35 11','Active Anti Ram Bollards',#1841,$,$); +#1843=IFCCLASSIFICATIONREFERENCE($,'23-11 29 35 13','Passive Anti Ram Bollards',#1841,$,$); +#1844=IFCCLASSIFICATIONREFERENCE($,'23-11 29 35 15','Architectural Bollards',#1841,$,$); +#1845=IFCCLASSIFICATIONREFERENCE($,'23-11 29 37','Public Lighting Columns',#1796,$,$); +#1846=IFCCLASSIFICATIONREFERENCE($,'23-11 31 00','Athletic and Recreational Surfaces',#1607,$,$); +#1847=IFCCLASSIFICATIONREFERENCE($,'23-11 31 11','Sports Field Surfacing',#1846,$,$); +#1848=IFCCLASSIFICATIONREFERENCE($,'23-11 31 13','Playground Surfaces',#1846,$,$); +#1849=IFCCLASSIFICATIONREFERENCE($,'23-13 00 00','Structural and Exterior Enclosure Products',#1606,$,$); +#1850=IFCCLASSIFICATIONREFERENCE($,'23-13 11 00','Loose Granular Fills, Aggregates, Chips, and Fibers',#1849,$,$); +#1851=IFCCLASSIFICATIONREFERENCE($,'23-13 11 11','Powder Fillers',#1850,$,$); +#1852=IFCCLASSIFICATIONREFERENCE($,'23-13 11 11 11','Mineral Powder Fillers',#1851,$,$); +#1853=IFCCLASSIFICATIONREFERENCE($,'23-13 11 11 13','Metal Powder Fillers',#1851,$,$); +#1854=IFCCLASSIFICATIONREFERENCE($,'23-13 11 11 15','Synthetic Powder Fillers',#1851,$,$); +#1855=IFCCLASSIFICATIONREFERENCE($,'23-13 11 11 17','Residue Powder Fillers',#1851,$,$); +#1856=IFCCLASSIFICATIONREFERENCE($,'23-13 11 13','Aggregates',#1850,$,$); +#1857=IFCCLASSIFICATIONREFERENCE($,'23-13 11 13 11','Dense Fills and Aggregates',#1856,$,$); +#1858=IFCCLASSIFICATIONREFERENCE($,'23-13 11 13 13','Lightweight Fills and Aggregates',#1856,$,$); +#1859=IFCCLASSIFICATIONREFERENCE($,'23-13 11 13 15','Heavyweight Fills and Aggregates',#1856,$,$); +#1860=IFCCLASSIFICATIONREFERENCE($,'23-13 11 15','Fibers and Shavings',#1850,$,$); +#1861=IFCCLASSIFICATIONREFERENCE($,'23-13 11 15 11','Mineral Fibers and Shavings',#1860,$,$); +#1862=IFCCLASSIFICATIONREFERENCE($,'23-13 11 15 13','Vegetable Fibers and Shavings',#1860,$,$); +#1863=IFCCLASSIFICATIONREFERENCE($,'23-13 11 15 15','Synthetic Fibers and Shavings',#1860,$,$); +#1864=IFCCLASSIFICATIONREFERENCE($,'23-13 11 15 17','Other Fibers and Shavings',#1860,$,$); +#1865=IFCCLASSIFICATIONREFERENCE($,'23-13 13 00','Binding Agents and Admixtures',#1849,$,$); +#1866=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11','Binding Agents',#1865,$,$); +#1867=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11 11','Cement',#1866,$,$); +#1868=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11 11 11','Standard Cement',#1867,$,$); +#1869=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11 11 13','Specialized Cement',#1867,$,$); +#1870=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11 11 13 11','High Sulfate Resistant Cement',#1869,$,$); +#1871=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11 11 13 13','Low Alkali Cement',#1869,$,$); +#1872=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11 11 13 15','Low Heat Cement',#1869,$,$); +#1873=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11 11 13 17','Alumina Cement',#1869,$,$); +#1874=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11 13','Lime',#1866,$,$); +#1875=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11 13 11','Hydraulic Lime',#1874,$,$); +#1876=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11 13 13','Air Hardening Lime',#1874,$,$); +#1877=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11 15','Bitumen Asphalt',#1866,$,$); +#1878=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11 17','Resinous Binders',#1866,$,$); +#1879=IFCCLASSIFICATIONREFERENCE($,'23-13 13 11 19','Gypsum',#1866,$,$); +#1880=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13','Cement Admixtures',#1865,$,$); +#1881=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 11','Cement Plasticizing Agents',#1880,$,$); +#1882=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 13','Cement Water Retaining Agents',#1880,$,$); +#1883=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 15','Cement Air Entraining Agents',#1880,$,$); +#1884=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 17','Cement Gas Generating Agents',#1880,$,$); +#1885=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 19','Cement Setting Retarders',#1880,$,$); +#1886=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 21','Cement Setting Accelerators',#1880,$,$); +#1887=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 23','Cement Frostproofing Agents',#1880,$,$); +#1888=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 25','Cement Waterproofing Agents',#1880,$,$); +#1889=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 27','Cement Coloring Agents',#1880,$,$); +#1890=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 29','Cement Admixtures for Injections',#1880,$,$); +#1891=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 31','Cement Admixtures for Projections',#1880,$,$); +#1892=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 33','Cement Adherence Proofing Agents',#1880,$,$); +#1893=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 35','Cement Bonding Agents',#1880,$,$); +#1894=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 37','Cement Replacements',#1880,$,$); +#1895=IFCCLASSIFICATIONREFERENCE($,'23-13 13 13 39','Other Cement Admixtures',#1880,$,$); +#1896=IFCCLASSIFICATIONREFERENCE($,'23-13 13 15','Gypsum Admixtures',#1865,$,$); +#1897=IFCCLASSIFICATIONREFERENCE($,'23-13 15 00','Mixtures',#1849,$,$); +#1898=IFCCLASSIFICATIONREFERENCE($,'23-13 15 11','Concretes',#1897,$,$); +#1899=IFCCLASSIFICATIONREFERENCE($,'23-13 15 11 11','Cementitious Concretes',#1898,$,$); +#1900=IFCCLASSIFICATIONREFERENCE($,'23-13 15 11 13','Resinous Concretes',#1898,$,$); +#1901=IFCCLASSIFICATIONREFERENCE($,'23-13 15 11 15','Hydrocarbon Concretes',#1898,$,$); +#1902=IFCCLASSIFICATIONREFERENCE($,'23-13 15 11 17','Low Density Concretes',#1898,$,$); +#1903=IFCCLASSIFICATIONREFERENCE($,'23-13 15 13','Mortars',#1897,$,$); +#1904=IFCCLASSIFICATIONREFERENCE($,'23-13 15 13 11','Portland Cement Lime Mortars',#1903,$,$); +#1905=IFCCLASSIFICATIONREFERENCE($,'23-13 15 13 13','Masonry Cement Mortars',#1903,$,$); +#1906=IFCCLASSIFICATIONREFERENCE($,'23-13 15 13 15','Mortar Cements',#1903,$,$); +#1907=IFCCLASSIFICATIONREFERENCE($,'23-13 15 13 17','Gypsum Based Mortars',#1903,$,$); +#1908=IFCCLASSIFICATIONREFERENCE($,'23-13 15 13 19','Resinous Mortar',#1903,$,$); +#1909=IFCCLASSIFICATIONREFERENCE($,'23-13 15 13 21','Chemical Resistant Mortar',#1903,$,$); +#1910=IFCCLASSIFICATIONREFERENCE($,'23-13 15 13 23','Refractory Mortar',#1903,$,$); +#1911=IFCCLASSIFICATIONREFERENCE($,'23-13 15 13 25','Premixed Mortar',#1903,$,$); +#1912=IFCCLASSIFICATIONREFERENCE($,'23-13 15 13 27','Surface Bonding Mortar',#1903,$,$); +#1913=IFCCLASSIFICATIONREFERENCE($,'23-13 15 13 29','Mortar Pigments',#1903,$,$); +#1914=IFCCLASSIFICATIONREFERENCE($,'23-13 15 15','Grouts',#1897,$,$); +#1915=IFCCLASSIFICATIONREFERENCE($,'23-13 15 15 11','Concrete Grouts',#1914,$,$); +#1916=IFCCLASSIFICATIONREFERENCE($,'23-13 15 15 11 11','Shrink Resistant Concrete Grouts',#1915,$,$); +#1917=IFCCLASSIFICATIONREFERENCE($,'23-13 15 15 11 13','Catalyzed Metallic Concrete Grouts',#1915,$,$); +#1918=IFCCLASSIFICATIONREFERENCE($,'23-13 15 15 11 15','Epoxy Concrete Grouts',#1915,$,$); +#1919=IFCCLASSIFICATIONREFERENCE($,'23-13 15 15 11 17','Nonmetallic Concrete Grouts',#1915,$,$); +#1920=IFCCLASSIFICATIONREFERENCE($,'23-13 15 15 13','Masonry Grouts',#1914,$,$); +#1921=IFCCLASSIFICATIONREFERENCE($,'23-13 15 15 13 11','Chemical Resistant Masonry Grouts',#1920,$,$); +#1922=IFCCLASSIFICATIONREFERENCE($,'23-13 17 00','Profiles',#1849,$,$); +#1923=IFCCLASSIFICATIONREFERENCE($,'23-13 17 11','Rigid Profiles',#1922,$,$); +#1924=IFCCLASSIFICATIONREFERENCE($,'23-13 17 11 11','Ferrous Metal Rigid Profiles',#1923,$,$); +#1925=IFCCLASSIFICATIONREFERENCE($,'23-13 17 11 13','Non Ferrous Metal Rigid Profiles',#1923,$,$); +#1926=IFCCLASSIFICATIONREFERENCE($,'23-13 17 11 15','Wood Rigid Profiles',#1923,$,$); +#1927=IFCCLASSIFICATIONREFERENCE($,'23-13 17 11 15 11','Lumber Rigid Profiles',#1926,$,$); +#1928=IFCCLASSIFICATIONREFERENCE($,'23-13 17 11 15 11 11','Hardwood Rigid Profiles',#1927,$,$); +#1929=IFCCLASSIFICATIONREFERENCE($,'23-13 17 11 15 11 13','Softwood Rigid Profiles',#1927,$,$); +#1930=IFCCLASSIFICATIONREFERENCE($,'23-13 17 11 15 11 15','Laminated Rigid Profiles',#1927,$,$); +#1931=IFCCLASSIFICATIONREFERENCE($,'23-13 17 11 15 13','Non Structural Heavy Timber Rigid Profiles',#1926,$,$); +#1932=IFCCLASSIFICATIONREFERENCE($,'23-13 17 11 17','Plastic Rigid Profiles',#1923,$,$); +#1933=IFCCLASSIFICATIONREFERENCE($,'23-13 17 11 19','Composite Rigid Profiles',#1923,$,$); +#1934=IFCCLASSIFICATIONREFERENCE($,'23-13 17 13','Flexible Profiles',#1922,$,$); +#1935=IFCCLASSIFICATIONREFERENCE($,'23-13 17 13 11','Plastic Flexible Profiles',#1934,$,$); +#1936=IFCCLASSIFICATIONREFERENCE($,'23-13 17 13 13','Rubber Flexible Profiles',#1934,$,$); +#1937=IFCCLASSIFICATIONREFERENCE($,'23-13 17 13 13 11','Natural Rubber Flexible Profiles',#1936,$,$); +#1938=IFCCLASSIFICATIONREFERENCE($,'23-13 17 13 13 13','Butyl Flexible Profiles',#1936,$,$); +#1939=IFCCLASSIFICATIONREFERENCE($,'23-13 17 13 13 15','Neoprene Flexible Profiles',#1936,$,$); +#1940=IFCCLASSIFICATIONREFERENCE($,'23-13 17 13 13 17','Silicone Flexible Profiles',#1936,$,$); +#1941=IFCCLASSIFICATIONREFERENCE($,'23-13 17 13 13 19','Polysulfide Flexible Profiles',#1936,$,$); +#1942=IFCCLASSIFICATIONREFERENCE($,'23-13 17 15','Precast Profiles',#1922,$,$); +#1943=IFCCLASSIFICATIONREFERENCE($,'23-13 17 15 11','Precast Hollow Core Sheets',#1942,$,$); +#1944=IFCCLASSIFICATIONREFERENCE($,'23-13 17 15 13','Precast Tees',#1942,$,$); +#1945=IFCCLASSIFICATIONREFERENCE($,'23-13 17 15 15','Precast Double Tees',#1942,$,$); +#1946=IFCCLASSIFICATIONREFERENCE($,'23-13 17 17','Lath',#1922,$,$); +#1947=IFCCLASSIFICATIONREFERENCE($,'23-13 17 17 11','Gypsum Lath',#1946,$,$); +#1948=IFCCLASSIFICATIONREFERENCE($,'23-13 17 17 13','Lead Lined Lath',#1946,$,$); +#1949=IFCCLASSIFICATIONREFERENCE($,'23-13 17 17 15','Metal Lath',#1946,$,$); +#1950=IFCCLASSIFICATIONREFERENCE($,'23-13 17 17 17','Veneer Plaster Base Lath',#1946,$,$); +#1951=IFCCLASSIFICATIONREFERENCE($,'23-13 17 17 19','Wood Lath',#1946,$,$); +#1952=IFCCLASSIFICATIONREFERENCE($,'23-13 19 00','Sheets, Boards, and Slabs',#1849,$,$); +#1953=IFCCLASSIFICATIONREFERENCE($,'23-13 19 11','Thin Flexible Sheets',#1952,$,$); +#1954=IFCCLASSIFICATIONREFERENCE($,'23-13 19 11 11','Thin Sheets',#1953,$,$); +#1955=IFCCLASSIFICATIONREFERENCE($,'23-13 19 11 11 11','Thin Metal Sheets',#1954,$,$); +#1956=IFCCLASSIFICATIONREFERENCE($,'23-13 19 11 11 13','Thin Wood Sheets',#1954,$,$); +#1957=IFCCLASSIFICATIONREFERENCE($,'23-13 19 11 11 15','Building Papers',#1954,$,$); +#1958=IFCCLASSIFICATIONREFERENCE($,'23-13 19 11 11 17','Thin Plastic Sheets',#1954,$,$); +#1959=IFCCLASSIFICATIONREFERENCE($,'23-13 19 11 11 19','Thin Rubber Sheets',#1954,$,$); +#1960=IFCCLASSIFICATIONREFERENCE($,'23-13 19 11 13','Textiles',#1953,$,$); +#1961=IFCCLASSIFICATIONREFERENCE($,'23-13 19 11 15','Mesh for General Use',#1953,$,$); +#1962=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13','Rigid Sheets, Slabs, Plates',#1952,$,$); +#1963=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 11','Solid Sheets',#1962,$,$); +#1964=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 11 11','Solid Stone Sheets',#1963,$,$); +#1965=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 11 13','Solid Cementitious Sheets',#1963,$,$); +#1966=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 11 15','Solid Mineral Sheets',#1963,$,$); +#1967=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 11 17','Solid Glass Sheets',#1963,$,$); +#1968=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 11 19','Solid Metal Sheets',#1963,$,$); +#1969=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 11 21','Solid Wood Based Sheets',#1963,$,$); +#1970=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 11 23','Solid Plastic Sheets',#1963,$,$); +#1971=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 11 25','Solid Resin Sheets',#1963,$,$); +#1972=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 11 27','Solid Fiberglass Sheets',#1963,$,$); +#1973=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 13','Hollow Core Sheets',#1962,$,$); +#1974=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 13 11','Wood Based Hollow Core Sheets',#1973,$,$); +#1975=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 13 13','Mineral Hollow Core Sheets',#1973,$,$); +#1976=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 13 15','Metal Hollow Core Sheets',#1973,$,$); +#1977=IFCCLASSIFICATIONREFERENCE($,'23-13 19 13 13 17','Plastic Hollow Core Sheets',#1973,$,$); +#1978=IFCCLASSIFICATIONREFERENCE($,'23-13 19 15','Gratings',#1952,$,$); +#1979=IFCCLASSIFICATIONREFERENCE($,'23-13 19 17','Blankets, Quilts',#1952,$,$); +#1980=IFCCLASSIFICATIONREFERENCE($,'23-13 21 00','Blocks and Bricks',#1849,$,$); +#1981=IFCCLASSIFICATIONREFERENCE($,'23-13 21 11','Concrete Masonry Units',#1980,$,$); +#1982=IFCCLASSIFICATIONREFERENCE($,'23-13 21 11 11','Concrete Blocks',#1981,$,$); +#1983=IFCCLASSIFICATIONREFERENCE($,'23-13 21 11 13','Exposed Aggregate Concrete Masonry Units',#1981,$,$); +#1984=IFCCLASSIFICATIONREFERENCE($,'23-13 21 11 15','Fluted Concrete Masonry Units',#1981,$,$); +#1985=IFCCLASSIFICATIONREFERENCE($,'23-13 21 11 17','Interlocking Concrete Masonry Units',#1981,$,$); +#1986=IFCCLASSIFICATIONREFERENCE($,'23-13 21 11 19','Molded Face Concrete Masonry Units',#1981,$,$); +#1987=IFCCLASSIFICATIONREFERENCE($,'23-13 21 11 21','Prefaced Concrete Masonry Units',#1981,$,$); +#1988=IFCCLASSIFICATIONREFERENCE($,'23-13 21 11 23','Preinsulated Concrete Masonry Units',#1981,$,$); +#1989=IFCCLASSIFICATIONREFERENCE($,'23-13 21 11 25','Sound Absorbing Concrete Masonry Units',#1981,$,$); +#1990=IFCCLASSIFICATIONREFERENCE($,'23-13 21 11 27','Split Face Concrete Masonry Units',#1981,$,$); +#1991=IFCCLASSIFICATIONREFERENCE($,'23-13 21 13','Calcium Silicate Masonry Units',#1980,$,$); +#1992=IFCCLASSIFICATIONREFERENCE($,'23-13 21 15','Glass Masonry Units',#1980,$,$); +#1993=IFCCLASSIFICATIONREFERENCE($,'23-13 21 17','Adobe Masonry Units',#1980,$,$); +#1994=IFCCLASSIFICATIONREFERENCE($,'23-13 21 19','Clay Masonry Units',#1980,$,$); +#1995=IFCCLASSIFICATIONREFERENCE($,'23-13 21 19 11','Common Bricks',#1994,$,$); +#1996=IFCCLASSIFICATIONREFERENCE($,'23-13 21 19 13','Face Bricks',#1994,$,$); +#1997=IFCCLASSIFICATIONREFERENCE($,'23-13 21 19 15','Fire Bricks',#1994,$,$); +#1998=IFCCLASSIFICATIONREFERENCE($,'23-13 21 19 17','Glazed Bricks',#1994,$,$); +#1999=IFCCLASSIFICATIONREFERENCE($,'23-13 21 19 19','Ceramic Glazed Clay Masonry Units',#1994,$,$); +#2000=IFCCLASSIFICATIONREFERENCE($,'23-13 21 19 21','Clay Tile',#1994,$,$); +#2001=IFCCLASSIFICATIONREFERENCE($,'23-13 21 19 23','Structural Clay Tiles',#1994,$,$); +#2002=IFCCLASSIFICATIONREFERENCE($,'23-13 21 19 25','Clay Flue Linings',#1994,$,$); +#2003=IFCCLASSIFICATIONREFERENCE($,'23-13 21 19 27','Terra Cotta Units',#1994,$,$); +#2004=IFCCLASSIFICATIONREFERENCE($,'23-13 21 21','Masonry Anchorage and Reinforcement',#1980,$,$); +#2005=IFCCLASSIFICATIONREFERENCE($,'23-13 21 21 11','Masonry Reinforcing',#2004,$,$); +#2006=IFCCLASSIFICATIONREFERENCE($,'23-13 21 21 11 11','Continuous Joint Reinforcing',#2005,$,$); +#2007=IFCCLASSIFICATIONREFERENCE($,'23-13 21 21 11 13','Reinforcing Bars',#2005,$,$); +#2008=IFCCLASSIFICATIONREFERENCE($,'23-13 21 21 13','Masonry Ties',#2004,$,$); +#2009=IFCCLASSIFICATIONREFERENCE($,'23-13 21 21 13 11','Flexible Masonry Ties',#2008,$,$); +#2010=IFCCLASSIFICATIONREFERENCE($,'23-13 21 21 13 13','Masonry Veneer Ties',#2008,$,$); +#2011=IFCCLASSIFICATIONREFERENCE($,'23-13 21 21 13 15','Rigid Masonry Ties',#2008,$,$); +#2012=IFCCLASSIFICATIONREFERENCE($,'23-13 21 21 15','Masonry Anchors',#2004,$,$); +#2013=IFCCLASSIFICATIONREFERENCE($,'23-13 21 21 15 11','Masonry Veneer Anchors',#2012,$,$); +#2014=IFCCLASSIFICATIONREFERENCE($,'23-13 21 21 15 13','Stone Masonry Anchors',#2012,$,$); +#2015=IFCCLASSIFICATIONREFERENCE($,'23-13 21 23','Special Profiles for Masonry',#1980,$,$); +#2016=IFCCLASSIFICATIONREFERENCE($,'23-13 21 23 11','Special Masonry Shapes',#2015,$,$); +#2017=IFCCLASSIFICATIONREFERENCE($,'23-13 21 23 13','Masonry Sills and Thresholds',#2015,$,$); +#2018=IFCCLASSIFICATIONREFERENCE($,'23-13 21 23 15','Masonry Moldings',#2015,$,$); +#2019=IFCCLASSIFICATIONREFERENCE($,'23-13 21 23 17','Masonry Copings',#2015,$,$); +#2020=IFCCLASSIFICATIONREFERENCE($,'23-13 21 23 19','Masonry Quoins',#2015,$,$); +#2021=IFCCLASSIFICATIONREFERENCE($,'23-13 21 23 21','Masonry Cornices',#2015,$,$); +#2022=IFCCLASSIFICATIONREFERENCE($,'23-13 21 25','Structural Support for Masonry',#1980,$,$); +#2023=IFCCLASSIFICATIONREFERENCE($,'23-13 21 25 11','Lintels',#2022,$,$); +#2024=IFCCLASSIFICATIONREFERENCE($,'23-13 21 25 11 11','Lintel Former Units',#2023,$,$); +#2025=IFCCLASSIFICATIONREFERENCE($,'23-13 21 25 13','Wall Connectors and Starters',#2022,$,$); +#2026=IFCCLASSIFICATIONREFERENCE($,'23-13 21 25 15','Supports for Masonry',#2022,$,$); +#2027=IFCCLASSIFICATIONREFERENCE($,'23-13 21 25 15 11','Masonry Angles',#2026,$,$); +#2028=IFCCLASSIFICATIONREFERENCE($,'23-13 21 25 15 11 11','Masonry Shelf Angles',#2027,$,$); +#2029=IFCCLASSIFICATIONREFERENCE($,'23-13 21 25 15 13','Gussets',#2026,$,$); +#2030=IFCCLASSIFICATIONREFERENCE($,'23-13 21 27','Ancillary Products for Masonry',#1980,$,$); +#2031=IFCCLASSIFICATIONREFERENCE($,'23-13 21 27 11','Embedded Flashing',#2030,$,$); +#2032=IFCCLASSIFICATIONREFERENCE($,'23-13 21 27 13','Cavity Closers',#2030,$,$); +#2033=IFCCLASSIFICATIONREFERENCE($,'23-13 21 27 15','Cavity Weep and Ventilation Units',#2030,$,$); +#2034=IFCCLASSIFICATIONREFERENCE($,'23-13 21 27 15 11','Cavity Weeps',#2033,$,$); +#2035=IFCCLASSIFICATIONREFERENCE($,'23-13 21 27 15 13','Cavity Vents',#2033,$,$); +#2036=IFCCLASSIFICATIONREFERENCE($,'23-13 21 27 15 15','Cavity Drainage Material',#2033,$,$); +#2037=IFCCLASSIFICATIONREFERENCE($,'23-13 21 27 17','Masonry Joint Materials',#2030,$,$); +#2038=IFCCLASSIFICATIONREFERENCE($,'23-13 21 27 17 11','Masonry Control Joints',#2037,$,$); +#2039=IFCCLASSIFICATIONREFERENCE($,'23-13 21 27 17 13','Masonry Expansion Joints',#2037,$,$); +#2040=IFCCLASSIFICATIONREFERENCE($,'23-13 21 27 19','Airbricks',#2030,$,$); +#2041=IFCCLASSIFICATIONREFERENCE($,'23-13 23 00','Mechanical Fasteners, Adhesives, and Sealants',#1849,$,$); +#2042=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11','Mechanical Fasteners',#2041,$,$); +#2043=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 11','Cast In Anchorages',#2042,$,$); +#2044=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 11 11','Rail Anchors',#2043,$,$); +#2045=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 11 13','Screw Cases',#2043,$,$); +#2046=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 11 15','Anchor Blocks',#2043,$,$); +#2047=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 11 17','Cast In Anchorages Inserts',#2043,$,$); +#2048=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 11 17 11','Cast In Anchorages Inserts Adjustable Wedges',#2047,$,$); +#2049=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 11 17 13','Cast In Anchorages Inserts Adjustable Boxes',#2047,$,$); +#2050=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 11 17 15','Threaded Cast In Anchorages Inserts',#2047,$,$); +#2051=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 11 19','Dovetail Slots',#2043,$,$); +#2052=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 13','Multi Purpose Mechanical Fasteners',#2042,$,$); +#2053=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 13 11','Plugs',#2052,$,$); +#2054=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 13 13','Staples',#2052,$,$); +#2055=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 13 15','Nails',#2052,$,$); +#2056=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 13 17','Rivets',#2052,$,$); +#2057=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 13 19','Screws',#2052,$,$); +#2058=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 13 21','Bolts and Nuts',#2052,$,$); +#2059=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 13 23','Threaded Rods and Nuts',#2052,$,$); +#2060=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 13 25','Bandings',#2052,$,$); +#2061=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 15','Structural Mechanical Fasteners in Hardened Concrete and Masonry',#2042,$,$); +#2062=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 15 11','Expansion Anchors',#2061,$,$); +#2063=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 15 13','Undercut Anchors',#2061,$,$); +#2064=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 15 15','Bonded Anchors',#2061,$,$); +#2065=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 17','Mechanical Fasteners for Metal Structures',#2042,$,$); +#2066=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 19','Mechanical Fasteners for Wood Structures',#2042,$,$); +#2067=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 19 11','Nail Plates',#2066,$,$); +#2068=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 19 13','Wood Connectors',#2066,$,$); +#2069=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 19 15','Framing Anchors',#2066,$,$); +#2070=IFCCLASSIFICATIONREFERENCE($,'23-13 23 11 21','Mechanical Fasteners for Glass Structures',#2042,$,$); +#2071=IFCCLASSIFICATIONREFERENCE($,'23-13 23 13','Welded Joint Products',#2041,$,$); +#2072=IFCCLASSIFICATIONREFERENCE($,'23-13 23 13 11','Soldering Products',#2071,$,$); +#2073=IFCCLASSIFICATIONREFERENCE($,'23-13 23 13 13','Brazing Products',#2071,$,$); +#2074=IFCCLASSIFICATIONREFERENCE($,'23-13 23 13 15','Welding Products',#2071,$,$); +#2075=IFCCLASSIFICATIONREFERENCE($,'23-13 23 15','Adhesives',#2041,$,$); +#2076=IFCCLASSIFICATIONREFERENCE($,'23-13 23 15 11','Natural Adhesives and Glues',#2075,$,$); +#2077=IFCCLASSIFICATIONREFERENCE($,'23-13 23 15 13','Synthetic Adhesives',#2075,$,$); +#2078=IFCCLASSIFICATIONREFERENCE($,'23-13 23 15 15','Sound Proofing Adhesive',#2075,$,$); +#2079=IFCCLASSIFICATIONREFERENCE($,'23-13 23 17','General Purpose Tape',#2041,$,$); +#2080=IFCCLASSIFICATIONREFERENCE($,'23-13 23 19','Joint Fillers, Sealants, and Mastics',#2041,$,$); +#2081=IFCCLASSIFICATIONREFERENCE($,'23-13 23 19 11','Joint Fillers',#2080,$,$); +#2082=IFCCLASSIFICATIONREFERENCE($,'23-13 23 19 11 11','Backer Rods',#2081,$,$); +#2083=IFCCLASSIFICATIONREFERENCE($,'23-13 23 19 13','Putties',#2080,$,$); +#2084=IFCCLASSIFICATIONREFERENCE($,'23-13 23 19 15','Construction Sealants',#2080,$,$); +#2085=IFCCLASSIFICATIONREFERENCE($,'23-13 23 19 15 11','Elastomeric Construction Sealants',#2084,$,$); +#2086=IFCCLASSIFICATIONREFERENCE($,'23-13 23 19 15 13','Rigid Construction Sealants',#2084,$,$); +#2087=IFCCLASSIFICATIONREFERENCE($,'23-13 23 19 15 15','Sanitary Construction Sealants',#2084,$,$); +#2088=IFCCLASSIFICATIONREFERENCE($,'23-13 23 19 15 17','Chemical Resistant Construction Sealants',#2084,$,$); +#2089=IFCCLASSIFICATIONREFERENCE($,'23-13 23 19 15 19','Water Immersed Construction Sealants',#2084,$,$); +#2090=IFCCLASSIFICATIONREFERENCE($,'23-13 23 19 17','Preformed Joint Seals',#2080,$,$); +#2091=IFCCLASSIFICATIONREFERENCE($,'23-13 23 19 17 11','Compression Seals',#2090,$,$); +#2092=IFCCLASSIFICATIONREFERENCE($,'23-13 23 19 17 13','Joint Gaskets',#2090,$,$); +#2093=IFCCLASSIFICATIONREFERENCE($,'23-13 23 21','Ropes, Wires, and Cables',#2041,$,$); +#2094=IFCCLASSIFICATIONREFERENCE($,'23-13 23 21 11','Ropes',#2093,$,$); +#2095=IFCCLASSIFICATIONREFERENCE($,'23-13 23 21 13','Wires',#2093,$,$); +#2096=IFCCLASSIFICATIONREFERENCE($,'23-13 23 21 15','Cables',#2093,$,$); +#2097=IFCCLASSIFICATIONREFERENCE($,'23-13 25 00','Thermal and Moisture Protective Products',#1849,$,$); +#2098=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11','Fireproofing',#2097,$,$); +#2099=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11 11','Board Fireproofing',#2098,$,$); +#2100=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11 11 11','Calcium Silicate Board Fireproofing',#2099,$,$); +#2101=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11 11 13','Slag Fiberboard Fireproofing',#2099,$,$); +#2102=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11 13','Blanket Fireproofing',#2098,$,$); +#2103=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11 13 11','Blanket Fireproofing Smoke Containment Barriers',#2102,$,$); +#2104=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11 15','Fireproofing Coatings',#2098,$,$); +#2105=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11 15 11','Cement Aggregate Fireproofing',#2104,$,$); +#2106=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11 15 13','Cementitious Fireproofing',#2104,$,$); +#2107=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11 15 15','Foamed Magnesium Oxychloride Fireproofing',#2104,$,$); +#2108=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11 15 17','Intumescent Mastic Fireproofing',#2104,$,$); +#2109=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11 15 19','Magnesium Cement Fireproofing',#2104,$,$); +#2110=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11 15 21','Mineral Fiber Cementitious Fireproofing',#2104,$,$); +#2111=IFCCLASSIFICATIONREFERENCE($,'23-13 25 11 15 23','Miner Fiber Fireproofing',#2104,$,$); +#2112=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13','Firestopping',#2097,$,$); +#2113=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13 11','Penetrations Firestopping',#2112,$,$); +#2114=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13 11 11','Annular Space Protection Firestopping',#2113,$,$); +#2115=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13 11 13','Fire Resistant Joint Sealants',#2113,$,$); +#2116=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13 11 15','Firestopping Foams',#2113,$,$); +#2117=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13 11 15 11','Intumescent Firestopping Foams',#2116,$,$); +#2118=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13 11 15 13','Silicone Firestopping Foams',#2116,$,$); +#2119=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13 11 17','Firestopping Mortars',#2113,$,$); +#2120=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13 11 19','Firestopping Pillows',#2113,$,$); +#2121=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13 11 21','Firestopping Thermal Barriers for Plastics',#2113,$,$); +#2122=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13 13','Fire Safing',#2112,$,$); +#2123=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13 13 11','Fire Safing Fibrous Blankets',#2122,$,$); +#2124=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13 13 13','Fire Safing Sealants',#2122,$,$); +#2125=IFCCLASSIFICATIONREFERENCE($,'23-13 25 13 13 15','Fire Safing Clip Anchors',#2122,$,$); +#2126=IFCCLASSIFICATIONREFERENCE($,'23-13 25 15','Dampproofings',#2097,$,$); +#2127=IFCCLASSIFICATIONREFERENCE($,'23-13 25 15 11','Dampproofing Membranes',#2126,$,$); +#2128=IFCCLASSIFICATIONREFERENCE($,'23-13 25 15 13','Dampproofing Coatings',#2126,$,$); +#2129=IFCCLASSIFICATIONREFERENCE($,'23-13 25 15 13 11','Bituminous Dampproofing Coatings',#2128,$,$); +#2130=IFCCLASSIFICATIONREFERENCE($,'23-13 25 15 13 13','Cementitious Dampproofing Coatings',#2128,$,$); +#2131=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17','Waterproofing',#2097,$,$); +#2132=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 11','Built Up Bituminous Waterproofing',#2131,$,$); +#2133=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 13','Sheet Waterproofing',#2131,$,$); +#2134=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 13 11','Bituminous Sheet Waterproofing',#2133,$,$); +#2135=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 13 13','Elastomeric Sheet Waterproofing',#2133,$,$); +#2136=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 13 15','Modified Bituminous Sheet Waterproofing',#2133,$,$); +#2137=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 13 17','Thermoplastic Sheet Waterproofing',#2133,$,$); +#2138=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 15','Fluid Applied Waterproofing',#2131,$,$); +#2139=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 15 11','Hot Applied Rubberized Asphalt',#2138,$,$); +#2140=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 17','Sheet Metal Waterproofing',#2131,$,$); +#2141=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 19','Cementitious and Reactive Waterproofing',#2131,$,$); +#2142=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 19 11','Acrylic Modified Cement Waterproofing',#2141,$,$); +#2143=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 19 13','Crystalline Waterproofing',#2141,$,$); +#2144=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 19 15','Metal Oxide Waterproofing',#2141,$,$); +#2145=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 21','Bentonite Waterproofing',#2131,$,$); +#2146=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 21 11','Bentonite Panel Waterproofing',#2145,$,$); +#2147=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 21 13','Bentonite Sheet Waterproofing',#2145,$,$); +#2148=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 23','Waterproof Traffic Coatings',#2131,$,$); +#2149=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 23 11','Pedestrian Waterproof Traffic Coatings',#2148,$,$); +#2150=IFCCLASSIFICATIONREFERENCE($,'23-13 25 17 23 13','Vehicular Waterproof Traffic Coatings',#2148,$,$); +#2151=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19','Thermal Insulation',#2097,$,$); +#2152=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 11','Slab and Board Thermal Insulation',#2151,$,$); +#2153=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 11 11','Polystyrene Slab and Board Thermal Insulation',#2152,$,$); +#2154=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 11 11 11','Expanded Polystyrene Slab and Board Thermal Insulation',#2153,$,$); +#2155=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 11 11 13','Extruded Polystyrene Slab and Board Thermal Insulation',#2153,$,$); +#2156=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 11 13','Urethane Slab and Board Thermal Insulation',#2152,$,$); +#2157=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 11 15','Perlite Slab and Board Thermal Insulation',#2152,$,$); +#2158=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 11 17','Fiberglass Slab and Board Thermal Insulation',#2152,$,$); +#2159=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 13','Blanket Thermal Insulation',#2151,$,$); +#2160=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 13 11','Fiberglass Blanket Thermal Insulation',#2159,$,$); +#2161=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 13 13','Rock Wool Blanket Thermal Insulation',#2159,$,$); +#2162=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 15','Thermal Insulation Coatings',#2151,$,$); +#2163=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 15 11','Sprayed Thermal Insulation Coatings',#2162,$,$); +#2164=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 15 11 11','Sprayed Cellulose Thermal Insulation Coatings',#2163,$,$); +#2165=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 17','Loose Fill Thermal Insulation',#2151,$,$); +#2166=IFCCLASSIFICATIONREFERENCE($,'23-13 25 19 17 11','Granular Fill Thermal Insulation',#2165,$,$); +#2167=IFCCLASSIFICATIONREFERENCE($,'23-13 25 21','Sound Isolation Insulation',#2097,$,$); +#2168=IFCCLASSIFICATIONREFERENCE($,'23-13 25 21 11','Slab and Board Sound Isolation Insulation',#2167,$,$); +#2169=IFCCLASSIFICATIONREFERENCE($,'23-13 25 21 13','Fiberglass Slab and Board Sound Isolation Insulation',#2167,$,$); +#2170=IFCCLASSIFICATIONREFERENCE($,'23-13 25 21 15','Blanket Sound Isolation Insulation',#2167,$,$); +#2171=IFCCLASSIFICATIONREFERENCE($,'23-13 25 21 15 11','Fiberglass Blanket Sound Isolation Insulation',#2170,$,$); +#2172=IFCCLASSIFICATIONREFERENCE($,'23-13 25 21 15 13','Rock Wool Blanket Sound Isolation Insulation',#2170,$,$); +#2173=IFCCLASSIFICATIONREFERENCE($,'23-13 25 21 17','Sound Isolation Coatings',#2167,$,$); +#2174=IFCCLASSIFICATIONREFERENCE($,'23-13 25 21 19','Sound Isolation Loose Fills',#2167,$,$); +#2175=IFCCLASSIFICATIONREFERENCE($,'23-13 25 21 19 11','Granular Sound Isolation Loose Fills',#2174,$,$); +#2176=IFCCLASSIFICATIONREFERENCE($,'23-13 25 23','Damage Prevention Products',#2097,$,$); +#2177=IFCCLASSIFICATIONREFERENCE($,'23-13 25 23 11','Products for Prevention of Biological Damage',#2176,$,$); +#2178=IFCCLASSIFICATIONREFERENCE($,'23-13 25 23 11 11','Coatings for Prevention of Biological Damage',#2177,$,$); +#2179=IFCCLASSIFICATIONREFERENCE($,'23-13 25 23 13','Products for Prevention of Chemical Damage',#2176,$,$); +#2180=IFCCLASSIFICATIONREFERENCE($,'23-13 25 23 13 11','Tiles and Slabs for Prevention of Chemical Damage',#2179,$,$); +#2181=IFCCLASSIFICATIONREFERENCE($,'23-13 25 23 13 13','Sheets for Prevention of Chemical Damage',#2179,$,$); +#2182=IFCCLASSIFICATIONREFERENCE($,'23-13 25 23 13 15','Coatings for Prevention of Chemical Damage',#2179,$,$); +#2183=IFCCLASSIFICATIONREFERENCE($,'23-13 25 23 15','Products for Prevention of Abrasive Wear',#2176,$,$); +#2184=IFCCLASSIFICATIONREFERENCE($,'23-13 25 25','Air Barriers',#2097,$,$); +#2185=IFCCLASSIFICATIONREFERENCE($,'23-13 25 27','Vapor Barriers',#2097,$,$); +#2186=IFCCLASSIFICATIONREFERENCE($,'23-13 27 00','Maintenance Products and Chemicals for Construction',#1849,$,$); +#2187=IFCCLASSIFICATIONREFERENCE($,'23-13 27 11','Cleaning and Maintenance Products',#2186,$,$); +#2188=IFCCLASSIFICATIONREFERENCE($,'23-13 27 11 11','Cleaning Products',#2187,$,$); +#2189=IFCCLASSIFICATIONREFERENCE($,'23-13 27 11 13','Maintenance Products',#2187,$,$); +#2190=IFCCLASSIFICATIONREFERENCE($,'23-13 27 11 15','Combined Cleaning and Protection Products',#2187,$,$); +#2191=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13','Repair Products',#2186,$,$); +#2192=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 11','Repair Mortars',#2191,$,$); +#2193=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 13','Concrete Restoration and Cleaning Products',#2191,$,$); +#2194=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 13 11','Concrete Cleaning Products',#2193,$,$); +#2195=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 13 13','Concrete Resurfacing Products',#2193,$,$); +#2196=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 13 15','Concrete Rehabilitation Products',#2193,$,$); +#2197=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 15','Masonry Restoration and Cleaning Products',#2191,$,$); +#2198=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 15 11','Unit Masonry Restoration Products',#2197,$,$); +#2199=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 15 13','Stone Restoration products',#2197,$,$); +#2200=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 15 15','Unit Masonry Cleaning Products',#2197,$,$); +#2201=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 15 17','Stone Cleaning products',#2197,$,$); +#2202=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 17','Metal Restoration and Cleaning Products',#2191,$,$); +#2203=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 19','Wood and Plastic Restoration and Cleaning Products',#2191,$,$); +#2204=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 19 11','Wood Restoration and Cleaning Products',#2203,$,$); +#2205=IFCCLASSIFICATIONREFERENCE($,'23-13 27 13 19 13','Plastic Restoration and Cleaning Products',#2203,$,$); +#2206=IFCCLASSIFICATIONREFERENCE($,'23-13 27 15','Chemicals for Construction',#2186,$,$); +#2207=IFCCLASSIFICATIONREFERENCE($,'23-13 27 15 11','Solvents',#2206,$,$); +#2208=IFCCLASSIFICATIONREFERENCE($,'23-13 27 15 13','Acids',#2206,$,$); +#2209=IFCCLASSIFICATIONREFERENCE($,'23-13 27 15 15','Alkalis',#2206,$,$); +#2210=IFCCLASSIFICATIONREFERENCE($,'23-13 27 15 17','Salts',#2206,$,$); +#2211=IFCCLASSIFICATIONREFERENCE($,'23-13 29 00','Foundations',#1849,$,$); +#2212=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11','Foundation Piles',#2211,$,$); +#2213=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 11','Foundation Pile Components',#2212,$,$); +#2214=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 11 11','Pile Casings (Linings)',#2213,$,$); +#2215=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 11 13','Cores and Mandrels',#2213,$,$); +#2216=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 11 15','Pile Extension Pieces',#2213,$,$); +#2217=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 11 17','Pile Shoes',#2213,$,$); +#2218=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 11 19','Pile Splices',#2213,$,$); +#2219=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 11 21','Pile Caps',#2213,$,$); +#2220=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 13','Driven Piles',#2212,$,$); +#2221=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 13 11','Composite Driven Piles',#2220,$,$); +#2222=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 13 13','Concrete Filled Steel Driven Piles',#2220,$,$); +#2223=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 13 15','Precast Concrete Driven Piles',#2220,$,$); +#2224=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 13 17','Rolled Steel Section Driven Piles',#2220,$,$); +#2225=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 13 19','Unfilled Tubular Steel Driven Piles',#2220,$,$); +#2226=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 13 21','Wood Driven Piles',#2220,$,$); +#2227=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 13 23','Sheet Driven Piles',#2220,$,$); +#2228=IFCCLASSIFICATIONREFERENCE($,'23-13 29 11 15','Screw Piles',#2212,$,$); +#2229=IFCCLASSIFICATIONREFERENCE($,'23-13 29 13','Caissons, Foundation Casings',#2211,$,$); +#2230=IFCCLASSIFICATIONREFERENCE($,'23-13 29 13 11','Well Foundation Casings',#2229,$,$); +#2231=IFCCLASSIFICATIONREFERENCE($,'23-13 29 13 13','Caissons',#2229,$,$); +#2232=IFCCLASSIFICATIONREFERENCE($,'23-13 29 15','Shallow Foundations',#2211,$,$); +#2233=IFCCLASSIFICATIONREFERENCE($,'23-13 29 15 11','Column Bases',#2232,$,$); +#2234=IFCCLASSIFICATIONREFERENCE($,'23-13 29 15 13','Grade Beams',#2232,$,$); +#2235=IFCCLASSIFICATIONREFERENCE($,'23-13 29 15 15','Strip Foundation Blocks',#2232,$,$); +#2236=IFCCLASSIFICATIONREFERENCE($,'23-13 29 17','Special Foundations',#2211,$,$); +#2237=IFCCLASSIFICATIONREFERENCE($,'23-13 29 17 11','Controlled Modulus Columns',#2236,$,$); +#2238=IFCCLASSIFICATIONREFERENCE($,'23-13 29 17 13','Other Special Foundations',#2236,$,$); +#2239=IFCCLASSIFICATIONREFERENCE($,'23-13 31 00','Structural Concrete Products',#1849,$,$); +#2240=IFCCLASSIFICATIONREFERENCE($,'23-13 31 11','Structural Concrete',#2239,$,$); +#2241=IFCCLASSIFICATIONREFERENCE($,'23-13 31 13','Ready Mixed Concrete',#2239,$,$); +#2242=IFCCLASSIFICATIONREFERENCE($,'23-13 31 15','Precast Structural Concrete',#2239,$,$); +#2243=IFCCLASSIFICATIONREFERENCE($,'23-13 31 17','Concrete Formwork',#2239,$,$); +#2244=IFCCLASSIFICATIONREFERENCE($,'23-13 31 17 11','Steel Forms',#2243,$,$); +#2245=IFCCLASSIFICATIONREFERENCE($,'23-13 31 17 13','Prefabricated Stair Forms',#2243,$,$); +#2246=IFCCLASSIFICATIONREFERENCE($,'23-13 31 17 15','Concrete Form Liners',#2243,$,$); +#2247=IFCCLASSIFICATIONREFERENCE($,'23-13 31 17 17','Insulated Concrete Forms',#2243,$,$); +#2248=IFCCLASSIFICATIONREFERENCE($,'23-13 31 19','Non Formwork',#2239,$,$); +#2249=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21','Reinforcement and Prestressing Components',#2239,$,$); +#2250=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 11','Reinforcement Components',#2249,$,$); +#2251=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 11 11','Reinforcing Steel',#2250,$,$); +#2252=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 11 13','Reinforcement Steel Mesh',#2250,$,$); +#2253=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 11 13 11','Welded Wire Fabric Reinforcing',#2252,$,$); +#2254=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 11 15','Fibrous Reinforcing',#2250,$,$); +#2255=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 11 15 11','Steel Fibrous Reinforcing',#2254,$,$); +#2256=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 11 15 13','Synthetic Fibrous Reinforcing',#2254,$,$); +#2257=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 11 17','Reinforcement Couplers',#2250,$,$); +#2258=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 11 19','Reinforcement Spacers',#2250,$,$); +#2259=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 11 21','Reinforcement Accessories',#2250,$,$); +#2260=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 13','Prestressing Components',#2249,$,$); +#2261=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 13 11','Stressing Tendons',#2260,$,$); +#2262=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 13 11 11','Steel Stressing Tendons',#2261,$,$); +#2263=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 13 11 11 11','Steel Strand Stressing Tendons',#2262,$,$); +#2264=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 13 11 11 13','Steel Wire Stressing Tendons',#2262,$,$); +#2265=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 13 11 11 15','Steel Bar Stressing Tendons',#2262,$,$); +#2266=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 13 11 13','Glass Fibers',#2261,$,$); +#2267=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 13 13','Steel Bars',#2260,$,$); +#2268=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 13 15','Glass Fiber Tendons',#2260,$,$); +#2269=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 13 17','Prestressing Couplers',#2260,$,$); +#2270=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 13 19','Tendon Sheathing',#2260,$,$); +#2271=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 13 19 11','Tendon Sheathing Ducts',#2270,$,$); +#2272=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 13 21','Prestressing Anchorages',#2260,$,$); +#2273=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 15','Post Tensioning Products',#2249,$,$); +#2274=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 17','Complete Reinforcement Cages',#2249,$,$); +#2275=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 19','Cast In Jointing',#2249,$,$); +#2276=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 19 11','Expansion and Contraction Joints',#2275,$,$); +#2277=IFCCLASSIFICATIONREFERENCE($,'23-13 31 21 19 13','Waterstops',#2275,$,$); +#2278=IFCCLASSIFICATIONREFERENCE($,'23-13 31 23','Concrete Finishing Products',#2239,$,$); +#2279=IFCCLASSIFICATIONREFERENCE($,'23-13 31 23 11','Stamped Concrete Finishing Products',#2278,$,$); +#2280=IFCCLASSIFICATIONREFERENCE($,'23-13 31 23 13','Colored Concrete Finishing Products',#2278,$,$); +#2281=IFCCLASSIFICATIONREFERENCE($,'23-13 33 00','Envelope Enclosure Products',#1849,$,$); +#2282=IFCCLASSIFICATIONREFERENCE($,'23-13 33 11','Sliding Glass Wall Systems',#2281,$,$); +#2283=IFCCLASSIFICATIONREFERENCE($,'23-13 33 13','Folding Glass Wall Systems',#2281,$,$); +#2284=IFCCLASSIFICATIONREFERENCE($,'23-13 33 15','Wall Exteriors',#2281,$,$); +#2285=IFCCLASSIFICATIONREFERENCE($,'23-13 33 15 11','Blast Resistant Wall Exteriors',#2284,$,$); +#2286=IFCCLASSIFICATIONREFERENCE($,'23-13 33 17','Infill Facades',#2281,$,$); +#2287=IFCCLASSIFICATIONREFERENCE($,'23-13 33 17 11','Exterior Wall Assemblies',#2286,$,$); +#2288=IFCCLASSIFICATIONREFERENCE($,'23-13 33 19','Precast Concrete Facade',#2281,$,$); +#2289=IFCCLASSIFICATIONREFERENCE($,'23-13 33 19 11','Cladding and Curtainwall Panels',#2288,$,$); +#2290=IFCCLASSIFICATIONREFERENCE($,'23-13 33 19 11 11','Opening Infill Units',#2289,$,$); +#2291=IFCCLASSIFICATIONREFERENCE($,'23-13 33 19 11 13','Imbedded Material Finish Mix, Tiles, Brick',#2289,$,$); +#2292=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21','Entrances',#2281,$,$); +#2293=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 11','Aluminum-Framed Entrances',#2292,$,$); +#2294=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 11 11','Automatic Aluminum-Framed Entrances',#2293,$,$); +#2295=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 11 13','Revolving Door Aluminum-Framed Entrances',#2293,$,$); +#2296=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 11 15','Balanced Door Aluminum-Framed Entrances',#2293,$,$); +#2297=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 11 17','Pressure-Resistant Aluminum-Framed Entrances',#2293,$,$); +#2298=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 11 19','Intensive Care Unit/Critical Care Unit Aluminum-Framed Entrances',#2293,$,$); +#2299=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 13','Bronze-Framed Entrances',#2292,$,$); +#2300=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 13 11','Automatic Bronze-Framed Entrances',#2299,$,$); +#2301=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 13 13','Revolving Door Bronze-Framed Entrances',#2299,$,$); +#2302=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 13 15','Balanced Door Bronze-Framed Entrances',#2299,$,$); +#2303=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 13 17','Pressure-Resistant Bronze-Framed Entrances',#2299,$,$); +#2304=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 13 19','Intensive Care Unit/Critical Care Unit Bronze-Framed Entrances',#2299,$,$); +#2305=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 15','Stainless-Steel-Framed Entrances',#2292,$,$); +#2306=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 15 11','Automatic Stainless-Steel-Framed Entrances',#2305,$,$); +#2307=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 15 13','Revolving Door Stainless-Steel-Framed Entrances',#2305,$,$); +#2308=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 15 15','Balanced Door Stainless-Steel-Framed Entrances',#2305,$,$); +#2309=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 15 17','Pressure-Resistant Stainless-Steel-Framed Entrances',#2305,$,$); +#2310=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 15 19','Intensive Care Unit/Critical Care Unit Stainless-Steel-Framed Entrances',#2305,$,$); +#2311=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 17','Steel-Framed Entrances',#2292,$,$); +#2312=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 17 11','Automatic Steel-Framed Entrances',#2311,$,$); +#2313=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 17 13','Revolving Door Steel-Framed Entrances',#2311,$,$); +#2314=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 17 15','Balanced Door Steel-Framed Entrances',#2311,$,$); +#2315=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 17 17','Pressure-Resistant Steel-Framed Entrances',#2311,$,$); +#2316=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 17 19','Intensive Care Unit/Critical Care Unit Steel-Framed Entrances',#2311,$,$); +#2317=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 19','All-Glass Entrances',#2292,$,$); +#2318=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 19 11','Automatic All-Glass Entrances',#2317,$,$); +#2319=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 19 13','Revolving Door All-Glass Entrances',#2317,$,$); +#2320=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 19 15','Balanced Door All-Glass Entrances',#2317,$,$); +#2321=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 19 17','Pressure-Resistant All-Glass Entrances',#2317,$,$); +#2322=IFCCLASSIFICATIONREFERENCE($,'23-13 33 21 19 19','Intensive Care Unit/Critical Care Unit All-Glass Entrances',#2317,$,$); +#2323=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23','Storefronts',#2281,$,$); +#2324=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 11','Aluminum-Framed Storefronts',#2323,$,$); +#2325=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 11 11','Automatic Aluminum-Framed Storefronts',#2324,$,$); +#2326=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 11 13','Revolving Door Aluminum-Framed Storefronts',#2324,$,$); +#2327=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 11 15','Balanced Door Aluminum-Framed Storefronts',#2324,$,$); +#2328=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 11 17','Pressure-Resistant Aluminum-Framed Storefronts',#2324,$,$); +#2329=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 11 19','Intensive Care Unit/Critical Care Unit Aluminum-Framed Storefronts',#2324,$,$); +#2330=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 13','Bronze-Framed Storefronts',#2323,$,$); +#2331=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 13 11','Automatic Bronze-Framed Storefronts',#2330,$,$); +#2332=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 13 13','Revolving Door Bronze-Framed Storefronts',#2330,$,$); +#2333=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 13 15','Balanced Door Bronze-Framed Storefronts',#2330,$,$); +#2334=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 13 17','Pressure-Resistant Bronze-Framed Storefronts',#2330,$,$); +#2335=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 13 19','Intensive Care Unit/Critical Care Unit Bronze-Framed Storefronts',#2330,$,$); +#2336=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 15','Stainless-Steel-Framed Storefronts',#2323,$,$); +#2337=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 15 11','Automatic Stainless-Steel-Framed Storefronts',#2336,$,$); +#2338=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 15 13','Revolving Door Stainless-Steel-Framed Storefronts',#2336,$,$); +#2339=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 15 15','Balanced Door Stainless-Steel-Framed Storefronts',#2336,$,$); +#2340=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 15 17','Pressure-Resistant Stainless-Steel-Framed Storefronts',#2336,$,$); +#2341=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 15 19','Intensive Care Unit/Critical Care Unit Stainless-Steel-Framed Storefronts',#2336,$,$); +#2342=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 17','Steel-Framed Storefronts',#2323,$,$); +#2343=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 17 11','Automatic Steel-Framed Storefronts',#2342,$,$); +#2344=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 17 13','Revolving Door Steel-Framed Storefronts',#2342,$,$); +#2345=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 17 15','Balanced Door Steel-Framed Storefronts',#2342,$,$); +#2346=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 17 17','Pressure-Resistant Steel-Framed Storefronts',#2342,$,$); +#2347=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 17 19','Intensive Care Unit/Critical Care Unit Steel-Framed Storefronts',#2342,$,$); +#2348=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 19','All-Glass Storefronts',#2323,$,$); +#2349=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 19 11','Automatic All-Glass Storefronts',#2348,$,$); +#2350=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 19 13','Revolving Door All-Glass Storefronts',#2348,$,$); +#2351=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 19 15','Balanced Door All-Glass Storefronts',#2348,$,$); +#2352=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 19 17','Pressure-Resistant All-Glass Storefronts',#2348,$,$); +#2353=IFCCLASSIFICATIONREFERENCE($,'23-13 33 23 19 19','Intensive Care Unit/Critical Care Unit All-Glass Storefronts',#2348,$,$); +#2354=IFCCLASSIFICATIONREFERENCE($,'23-13 33 25','Precast Modules',#2281,$,$); +#2355=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27','Glazed Facade and Roof Structures',#2281,$,$); +#2356=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 11','Curtain Walls',#2355,$,$); +#2357=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 11 11','Curtain Wall Components',#2356,$,$); +#2358=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 11 11 11','Curtain Wall Frames',#2357,$,$); +#2359=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 11 11 13','Curtain Wall Sections',#2357,$,$); +#2360=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 11 11 15','Curtain Wall Infill Panels',#2357,$,$); +#2361=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 11 13','Metal Framed Curtain Wall',#2356,$,$); +#2362=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 11 15','Translucent Curtain Wall Assemblies',#2356,$,$); +#2363=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 13','Structural Glazing',#2355,$,$); +#2364=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 13 11','Structural Glass Curtain Walls',#2363,$,$); +#2365=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 15','Suspended Glazing',#2355,$,$); +#2366=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 17','Patent Glazing',#2355,$,$); +#2367=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 19','Glazed Roof Structures',#2355,$,$); +#2368=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 19 11','Sections for Glazed Roofs',#2367,$,$); +#2369=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 19 13','Sloped Glazing Assemblies',#2367,$,$); +#2370=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 19 15','Translucent Roof Assemblies',#2367,$,$); +#2371=IFCCLASSIFICATIONREFERENCE($,'23-13 33 27 19 17','Translucent Wall Assemblies',#2367,$,$); +#2372=IFCCLASSIFICATIONREFERENCE($,'23-13 35 00','Framing Products',#1849,$,$); +#2373=IFCCLASSIFICATIONREFERENCE($,'23-13 35 11','Structural Frames',#2372,$,$); +#2374=IFCCLASSIFICATIONREFERENCE($,'23-13 35 11 11','Beam Column Frames',#2373,$,$); +#2375=IFCCLASSIFICATIONREFERENCE($,'23-13 35 11 13','Column Slab Frames',#2373,$,$); +#2376=IFCCLASSIFICATIONREFERENCE($,'23-13 35 11 13 11','Columns',#2375,$,$); +#2377=IFCCLASSIFICATIONREFERENCE($,'23-13 35 11 13 13','Beams',#2375,$,$); +#2378=IFCCLASSIFICATIONREFERENCE($,'23-13 35 11 15','Portal Frames',#2373,$,$); +#2379=IFCCLASSIFICATIONREFERENCE($,'23-13 35 11 17','Structural Racking',#2373,$,$); +#2380=IFCCLASSIFICATIONREFERENCE($,'23-13 35 11 19','Structural Bearings',#2373,$,$); +#2381=IFCCLASSIFICATIONREFERENCE($,'23-13 35 11 19 11','Structural Roller Bearings',#2380,$,$); +#2382=IFCCLASSIFICATIONREFERENCE($,'23-13 35 11 19 13','Structural Slide Bearings',#2380,$,$); +#2383=IFCCLASSIFICATIONREFERENCE($,'23-13 35 11 19 15','Structural Rocker Bearings',#2380,$,$); +#2384=IFCCLASSIFICATIONREFERENCE($,'23-13 35 11 19 17','Structural Fixed Bearings',#2380,$,$); +#2385=IFCCLASSIFICATIONREFERENCE($,'23-13 35 11 21','Vibration and Earthquake Controls',#2373,$,$); +#2386=IFCCLASSIFICATIONREFERENCE($,'23-13 35 13','Non Structural Framing Products',#2372,$,$); +#2387=IFCCLASSIFICATIONREFERENCE($,'23-13 35 15','Space Frames',#2372,$,$); +#2388=IFCCLASSIFICATIONREFERENCE($,'23-13 35 15 11','Booms Braces',#2387,$,$); +#2389=IFCCLASSIFICATIONREFERENCE($,'23-13 35 15 13','Couplers',#2387,$,$); +#2390=IFCCLASSIFICATIONREFERENCE($,'23-13 35 15 15','Complete Space Frames',#2387,$,$); +#2391=IFCCLASSIFICATIONREFERENCE($,'23-13 35 17','Geodesic Structures',#2372,$,$); +#2392=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19','Rafters, Beams, and Joists',#2372,$,$); +#2393=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 11','Trussed Rafters',#2392,$,$); +#2394=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 13','Trussed Beams and Joists',#2392,$,$); +#2395=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 13 11','Trussed Metal Joists',#2394,$,$); +#2396=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 13 13','Trussed Composite Joist Assemblies',#2394,$,$); +#2397=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 13 15','Trussed Metal Web Wood Joists',#2394,$,$); +#2398=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 13 17','Wood Trusses',#2394,$,$); +#2399=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 13 19','Metal Trusses',#2394,$,$); +#2400=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 15','Web Beams and Joists',#2392,$,$); +#2401=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 15 11','Wood Joists',#2400,$,$); +#2402=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 15 13','Wood Beams',#2400,$,$); +#2403=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 15 15','Heavy Timber Construction',#2400,$,$); +#2404=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 15 17','Engineered Wood Products',#2400,$,$); +#2405=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 17','Precast Concrete Beams',#2392,$,$); +#2406=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 17 11','Precast Concrete Doubletee Beams',#2405,$,$); +#2407=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 17 13','Precast Concrete Hollowcore Beams',#2405,$,$); +#2408=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 17 15','Precast Concrete Inverted Tee Beams',#2405,$,$); +#2409=IFCCLASSIFICATIONREFERENCE($,'23-13 35 19 17 17','Precast Concrete Spandrel Beams',#2405,$,$); +#2410=IFCCLASSIFICATIONREFERENCE($,'23-13 35 21','Structural Walls',#2372,$,$); +#2411=IFCCLASSIFICATIONREFERENCE($,'23-13 35 21 11','Concrete Structural Walls',#2410,$,$); +#2412=IFCCLASSIFICATIONREFERENCE($,'23-13 35 21 13','Masonry Structural Walls',#2410,$,$); +#2413=IFCCLASSIFICATIONREFERENCE($,'23-13 35 21 15','Wood Framed Structural Walls',#2410,$,$); +#2414=IFCCLASSIFICATIONREFERENCE($,'23-13 35 21 17','Metal Framed Structural Walls',#2410,$,$); +#2415=IFCCLASSIFICATIONREFERENCE($,'23-13 35 21 19','Structural Panels',#2410,$,$); +#2416=IFCCLASSIFICATIONREFERENCE($,'23-13 35 21 19 11','Cementitious Reinforced Structural Panels',#2415,$,$); +#2417=IFCCLASSIFICATIONREFERENCE($,'23-13 35 21 19 13','Stressed Skin Structural Panels',#2415,$,$); +#2418=IFCCLASSIFICATIONREFERENCE($,'23-13 35 21 19 15','Structural Insulated Panels',#2415,$,$); +#2419=IFCCLASSIFICATIONREFERENCE($,'23-13 35 21 21','Other Structural Walls',#2410,$,$); +#2420=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23','Structural Floors and Flat Roofs',#2372,$,$); +#2421=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 11','Structural Floor Decks',#2420,$,$); +#2422=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 11 11','Concrete Structural Floor Decks',#2421,$,$); +#2423=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 11 13','Metal Structural Floor Decks',#2421,$,$); +#2424=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 11 13 11','Raceway Deck Systems',#2423,$,$); +#2425=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 11 13 13','Acoustical Metal Floor Decks',#2423,$,$); +#2426=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 11 15','Wood Structural Floor Decks',#2421,$,$); +#2427=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 13','Structural Roof Decks',#2420,$,$); +#2428=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 13 11','Concrete Structural Roof Decks',#2427,$,$); +#2429=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 13 13','Metal Structural Roof Decks',#2427,$,$); +#2430=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 13 13 11','Acoustical Metal Roof Deck',#2429,$,$); +#2431=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 13 15','Wood Structural Roof Decks',#2427,$,$); +#2432=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 15','Structural Grating Floors',#2420,$,$); +#2433=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 17','Balconies and Overhang Units',#2420,$,$); +#2434=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 17 11','Balcony Components',#2433,$,$); +#2435=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 17 11 11','Balcony Holders and Mechanical Fasteners',#2434,$,$); +#2436=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 17 13','Concrete Balconies and Overhang Units',#2433,$,$); +#2437=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 17 15','Metal Balconies and Overhang Units',#2433,$,$); +#2438=IFCCLASSIFICATIONREFERENCE($,'23-13 35 23 17 17','Wood Balconies and Overhang Units',#2433,$,$); +#2439=IFCCLASSIFICATIONREFERENCE($,'23-13 35 25','Structural Profiled Roofs',#2372,$,$); +#2440=IFCCLASSIFICATIONREFERENCE($,'23-13 35 25 11','Prefabricated Shell Roofs',#2439,$,$); +#2441=IFCCLASSIFICATIONREFERENCE($,'23-13 35 25 13','Simulated Stones',#2439,$,$); +#2442=IFCCLASSIFICATIONREFERENCE($,'23-13 37 00','Multi-Function Exterior Coverings, Claddings, Linings',#1849,$,$); +#2443=IFCCLASSIFICATIONREFERENCE($,'23-13 37 11','Multi-Function Exterior Claddings',#2442,$,$); +#2444=IFCCLASSIFICATIONREFERENCE($,'23-13 37 13','Exterior Wall Cladding',#2442,$,$); +#2445=IFCCLASSIFICATIONREFERENCE($,'23-13 37 15','Exterior Siding',#2442,$,$); +#2446=IFCCLASSIFICATIONREFERENCE($,'23-13 37 15 11','Metal Exterior Siding',#2445,$,$); +#2447=IFCCLASSIFICATIONREFERENCE($,'23-13 37 15 13','Composition Exterior Siding',#2445,$,$); +#2448=IFCCLASSIFICATIONREFERENCE($,'23-13 37 15 15','Mineral Fiber Cement Exterior Siding',#2445,$,$); +#2449=IFCCLASSIFICATIONREFERENCE($,'23-13 37 15 17','Plastic Exterior Siding',#2445,$,$); +#2450=IFCCLASSIFICATIONREFERENCE($,'23-13 37 15 19','Wood Exterior Siding',#2445,$,$); +#2451=IFCCLASSIFICATIONREFERENCE($,'23-13 37 17','Multi Function Exterior Linings',#2442,$,$); +#2452=IFCCLASSIFICATIONREFERENCE($,'23-13 37 17 11','Sheathing Products',#2451,$,$); +#2453=IFCCLASSIFICATIONREFERENCE($,'23-13 37 19','Exterior Plasters',#2442,$,$); +#2454=IFCCLASSIFICATIONREFERENCE($,'23-13 37 21','Preformed Exterior Casings',#2442,$,$); +#2455=IFCCLASSIFICATIONREFERENCE($,'23-13 37 23','Ancillary Products for Coverings and Claddings',#2442,$,$); +#2456=IFCCLASSIFICATIONREFERENCE($,'23-13 37 23 11','Supports for Coverings and Claddings',#2455,$,$); +#2457=IFCCLASSIFICATIONREFERENCE($,'23-13 37 23 13','Mechanical Fasteners for Coverings and Claddings',#2455,$,$); +#2458=IFCCLASSIFICATIONREFERENCE($,'23-13 37 23 15','Movement and Dividing Joints for Coverings and Claddings',#2455,$,$); +#2459=IFCCLASSIFICATIONREFERENCE($,'23-13 37 23 17','Joint Coverings, Flashings, Tapes',#2455,$,$); +#2460=IFCCLASSIFICATIONREFERENCE($,'23-13 37 23 19','Reinforcements for Coverings and Claddings',#2455,$,$); +#2461=IFCCLASSIFICATIONREFERENCE($,'23-13 37 23 21','Trims, Edgings, Capping',#2455,$,$); +#2462=IFCCLASSIFICATIONREFERENCE($,'23-13 37 23 23','Spacers',#2455,$,$); +#2463=IFCCLASSIFICATIONREFERENCE($,'23-13 37 23 25','Profile Fillers',#2455,$,$); +#2464=IFCCLASSIFICATIONREFERENCE($,'23-13 37 23 27','Underlays, Linings, Separations',#2455,$,$); +#2465=IFCCLASSIFICATIONREFERENCE($,'23-13 37 23 29','Beddings, Adhesives for Coverings and Claddings',#2455,$,$); +#2466=IFCCLASSIFICATIONREFERENCE($,'23-13 37 23 31','Sealants for Coverings and Claddings',#2455,$,$); +#2467=IFCCLASSIFICATIONREFERENCE($,'23-13 39 00','Roof Coverings, Claddings, Linings',#1849,$,$); +#2468=IFCCLASSIFICATIONREFERENCE($,'23-13 39 11','Exterior Roof Panels',#2467,$,$); +#2469=IFCCLASSIFICATIONREFERENCE($,'23-13 39 11 11','Exterior Metal Roof Panels',#2468,$,$); +#2470=IFCCLASSIFICATIONREFERENCE($,'23-13 39 11 13','Exterior Plastic Roof Panels',#2468,$,$); +#2471=IFCCLASSIFICATIONREFERENCE($,'23-13 39 11 15','Exterior Wood Roof Panels',#2468,$,$); +#2472=IFCCLASSIFICATIONREFERENCE($,'23-13 39 11 17','Exterior Composite Roof Panels',#2468,$,$); +#2473=IFCCLASSIFICATIONREFERENCE($,'23-13 39 11 19','Exterior Faced Roof Panels',#2468,$,$); +#2474=IFCCLASSIFICATIONREFERENCE($,'23-13 39 11 21','Exterior Aggregate Coated Panels',#2468,$,$); +#2475=IFCCLASSIFICATIONREFERENCE($,'23-13 39 11 23','Exterior Porcelain Enameled Faced Panels',#2468,$,$); +#2476=IFCCLASSIFICATIONREFERENCE($,'23-13 39 11 25','Exterior Tile Faced Panels',#2468,$,$); +#2477=IFCCLASSIFICATIONREFERENCE($,'23-13 39 11 27','Exterior Fiber Reinforced Cementitious Panels',#2468,$,$); +#2478=IFCCLASSIFICATIONREFERENCE($,'23-13 39 11 29','Exterior Glass Fiber Reinforced Cementitious Panels',#2468,$,$); +#2479=IFCCLASSIFICATIONREFERENCE($,'23-13 39 11 31','Exterior Miner Fiber Reinforced Cementitious Panels',#2468,$,$); +#2480=IFCCLASSIFICATIONREFERENCE($,'23-13 39 13','Roof Underlayment',#2467,$,$); +#2481=IFCCLASSIFICATIONREFERENCE($,'23-13 39 15','Roof Shingles',#2467,$,$); +#2482=IFCCLASSIFICATIONREFERENCE($,'23-13 39 15 11','Asphalt Roof Shingles',#2481,$,$); +#2483=IFCCLASSIFICATIONREFERENCE($,'23-13 39 15 13','Fiberglass Reinforced Roof Shingles',#2481,$,$); +#2484=IFCCLASSIFICATIONREFERENCE($,'23-13 39 15 15','Metal Roof Shingles',#2481,$,$); +#2485=IFCCLASSIFICATIONREFERENCE($,'23-13 39 15 17','Mineral Fiber Cement Roof Shingles',#2481,$,$); +#2486=IFCCLASSIFICATIONREFERENCE($,'23-13 39 15 19','Plastic Roof Shingles',#2481,$,$); +#2487=IFCCLASSIFICATIONREFERENCE($,'23-13 39 15 21','Porcelain Enamel Roof Shingles',#2481,$,$); +#2488=IFCCLASSIFICATIONREFERENCE($,'23-13 39 15 23','Wood Shingles',#2481,$,$); +#2489=IFCCLASSIFICATIONREFERENCE($,'23-13 39 15 25','Concrete Roof Shingles',#2481,$,$); +#2490=IFCCLASSIFICATIONREFERENCE($,'23-13 39 17','Roof Tiles',#2467,$,$); +#2491=IFCCLASSIFICATIONREFERENCE($,'23-13 39 17 11','Clay Roof Tiles',#2490,$,$); +#2492=IFCCLASSIFICATIONREFERENCE($,'23-13 39 17 13','Concrete Roof Tiles',#2490,$,$); +#2493=IFCCLASSIFICATIONREFERENCE($,'23-13 39 17 15','Metal Roof Tiles',#2490,$,$); +#2494=IFCCLASSIFICATIONREFERENCE($,'23-13 39 17 17','Mineral Fiber Cement Roof Tiles',#2490,$,$); +#2495=IFCCLASSIFICATIONREFERENCE($,'23-13 39 17 19','Plastic Roof Tiles',#2490,$,$); +#2496=IFCCLASSIFICATIONREFERENCE($,'23-13 39 17 21','Ceramic Roof Tiles',#2490,$,$); +#2497=IFCCLASSIFICATIONREFERENCE($,'23-13 39 17 23','Tile Roof Mechanical Fasteners',#2490,$,$); +#2498=IFCCLASSIFICATIONREFERENCE($,'23-13 39 19','Natural Stone Roofing',#2467,$,$); +#2499=IFCCLASSIFICATIONREFERENCE($,'23-13 39 19 11','Roof Slates',#2498,$,$); +#2500=IFCCLASSIFICATIONREFERENCE($,'23-13 39 19 11 11','Slate Roof Mechanical Fasteners',#2499,$,$); +#2501=IFCCLASSIFICATIONREFERENCE($,'23-13 39 21','Shake Roofing',#2467,$,$); +#2502=IFCCLASSIFICATIONREFERENCE($,'23-13 39 21 11','Wood Shakes Roofing',#2501,$,$); +#2503=IFCCLASSIFICATIONREFERENCE($,'23-13 39 23','Flat Roofing',#2467,$,$); +#2504=IFCCLASSIFICATIONREFERENCE($,'23-13 39 23 11','Acoustical Metal Deck Roofing',#2503,$,$); +#2505=IFCCLASSIFICATIONREFERENCE($,'23-13 39 23 13','Structural Deck Roofing',#2503,$,$); +#2506=IFCCLASSIFICATIONREFERENCE($,'23-13 39 23 13 11','Concrete Structural Deck Roofing',#2505,$,$); +#2507=IFCCLASSIFICATIONREFERENCE($,'23-13 39 23 13 13','Metal Structural Deck Roofing',#2505,$,$); +#2508=IFCCLASSIFICATIONREFERENCE($,'23-13 39 23 15','Wood Decking Roofing',#2503,$,$); +#2509=IFCCLASSIFICATIONREFERENCE($,'23-13 39 25','Roof Finish Coating',#2467,$,$); +#2510=IFCCLASSIFICATIONREFERENCE($,'23-13 39 27','Roof Cladding',#2467,$,$); +#2511=IFCCLASSIFICATIONREFERENCE($,'23-13 39 27 11','Roof Cladding Sheets',#2510,$,$); +#2512=IFCCLASSIFICATIONREFERENCE($,'23-13 39 27 11 11','Metal Roof Panels',#2511,$,$); +#2513=IFCCLASSIFICATIONREFERENCE($,'23-13 39 27 11 13','Sheet Metal Roofing',#2511,$,$); +#2514=IFCCLASSIFICATIONREFERENCE($,'23-13 39 27 13','Roof Battens Cladding',#2510,$,$); +#2515=IFCCLASSIFICATIONREFERENCE($,'23-13 39 29','Roof Coverings',#2467,$,$); +#2516=IFCCLASSIFICATIONREFERENCE($,'23-13 39 29 11','Thatched Roofing',#2515,$,$); +#2517=IFCCLASSIFICATIONREFERENCE($,'23-13 39 29 13','Sod Roofing',#2515,$,$); +#2518=IFCCLASSIFICATIONREFERENCE($,'23-13 39 29 15','Vegetated Roof Covering',#2515,$,$); +#2519=IFCCLASSIFICATIONREFERENCE($,'23-13 39 29 15 11','Vegetated Roof Planting Modules',#2518,$,$); +#2520=IFCCLASSIFICATIONREFERENCE($,'23-13 39 29 17','Coated Foam Roof Covering',#2515,$,$); +#2521=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31','Roof Membranes',#2467,$,$); +#2522=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 11','Single Layer Roof Membranes',#2521,$,$); +#2523=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 11 11','Chlorinated Polyethylene (CPE) Single Layer Roof Membranes',#2522,$,$); +#2524=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 11 13','Chlorosulfonated Polyethylene (CSPE) Single Layer Roof Membranes',#2522,$,$); +#2525=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 11 15','Copolymer Alloy (CPA) Single Layer Roof Membranes',#2522,$,$); +#2526=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 11 17','Elastomeric Single Layer Roof Membranes',#2522,$,$); +#2527=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 11 19','Ethylene Interpolymer (EIP) Single Layer Roof Membranes',#2522,$,$); +#2528=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 11 21','Ethylene Propylene Diene Monomer (EPDM) Single Layer Roof Membranes',#2522,$,$); +#2529=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 11 23','Nitrile Butadiene Polymer (NBP) Single Layer Roof Membranes',#2522,$,$); +#2530=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 11 25','Polyisobutylene (PIB) Single Layer Roof Membranes',#2522,$,$); +#2531=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 11 27','Polyvinyl chloride (PVC) Single Layer Roof Membranes',#2522,$,$); +#2532=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 11 29','Thermoplastic Alloy (TPA) Single Layer Roof Membranes',#2522,$,$); +#2533=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 11 31','Thermoplastic Single Layer Roof Membranes',#2522,$,$); +#2534=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 13','Multi Layer Roof Membranes',#2521,$,$); +#2535=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 13 11','Asphalt Multi Layer Roof Membranes',#2534,$,$); +#2536=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 13 13','Built Up Bituminous Multi Layer Roof Membranes',#2534,$,$); +#2537=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 13 15','Coal Tar Multi Layer Roof Membranes',#2534,$,$); +#2538=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 13 17','Cold Applied Bituminous Multi Layer Roof Membranes',#2534,$,$); +#2539=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 13 19','Cold Applied Mastic Multi Layer Roof Membranes',#2534,$,$); +#2540=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 13 21','Glass Fiber Reinforced Asphalt Emulsion Multi Layer Roof Membranes',#2534,$,$); +#2541=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 13 23','Modified Bituminous Multi Layer Roof Membranes',#2534,$,$); +#2542=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 15','Fluid Applied Roofing',#2521,$,$); +#2543=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 17','Coated Foam Roofing',#2521,$,$); +#2544=IFCCLASSIFICATIONREFERENCE($,'23-13 39 31 19','Roll Roofing',#2521,$,$); +#2545=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33','Roof Decking',#2467,$,$); +#2546=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33 11','Cementitious Deck Roofing',#2545,$,$); +#2547=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33 11 11','Cementitious Composite Insulation Deck Roofing',#2546,$,$); +#2548=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33 11 13','Cementitious Lightweight Cellular Deck Roofing',#2546,$,$); +#2549=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33 11 15','Cementitious Lightweight Insulating Deck Roofing',#2546,$,$); +#2550=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33 13','Lightweight Concrete Roofing Insulation',#2545,$,$); +#2551=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33 13 11','Composite Concrete and Insulation Deck Roofing',#2550,$,$); +#2552=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33 13 13','Lightweight Cellular Concrete Deck Roofing',#2550,$,$); +#2553=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33 13 15','Lightweight Insulating Concrete Deck Roofing',#2550,$,$); +#2554=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33 15','Concrete Deck Roofing',#2545,$,$); +#2555=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33 15 11','Concrete Composite Insulation Deck Roofing',#2554,$,$); +#2556=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33 15 13','Concrete Lightweight Cellular Deck Roofing',#2554,$,$); +#2557=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33 15 15','Concrete Lightweight Insulating Deck Roofing',#2554,$,$); +#2558=IFCCLASSIFICATIONREFERENCE($,'23-13 39 33 17','Concrete Roof Topping',#2545,$,$); +#2559=IFCCLASSIFICATIONREFERENCE($,'23-13 39 35','Roof Finishing Coatings',#2467,$,$); +#2560=IFCCLASSIFICATIONREFERENCE($,'23-13 39 37','Renovation Products for Roof Coverings and Claddings',#2467,$,$); +#2561=IFCCLASSIFICATIONREFERENCE($,'23-13 41 00','Roof Specialties and Accessories',#1849,$,$); +#2562=IFCCLASSIFICATIONREFERENCE($,'23-13 41 11','Roof Edgings and Trims',#2561,$,$); +#2563=IFCCLASSIFICATIONREFERENCE($,'23-13 41 11 11','Roof Copings',#2562,$,$); +#2564=IFCCLASSIFICATIONREFERENCE($,'23-13 41 11 13','Roof Counterflashing Systems',#2562,$,$); +#2565=IFCCLASSIFICATIONREFERENCE($,'23-13 41 11 15','Roof Gravel Stops',#2562,$,$); +#2566=IFCCLASSIFICATIONREFERENCE($,'23-13 41 11 17','Roof Fascias',#2562,$,$); +#2567=IFCCLASSIFICATIONREFERENCE($,'23-13 41 11 19','Roof Reglets',#2562,$,$); +#2568=IFCCLASSIFICATIONREFERENCE($,'23-13 41 11 21','Roof Scuppers',#2562,$,$); +#2569=IFCCLASSIFICATIONREFERENCE($,'23-13 41 13','Roof Flashings',#2561,$,$); +#2570=IFCCLASSIFICATIONREFERENCE($,'23-13 41 13 11','Laminated Sheet Flexible Roof Flashings',#2569,$,$); +#2571=IFCCLASSIFICATIONREFERENCE($,'23-13 41 13 13','Modified Bituminous Sheet Flexible Roof Flashings',#2569,$,$); +#2572=IFCCLASSIFICATIONREFERENCE($,'23-13 41 13 15','Plastic Sheet Flexible Roof Flashings',#2569,$,$); +#2573=IFCCLASSIFICATIONREFERENCE($,'23-13 41 13 17','Rubber Sheet Flexible Roof Flashings',#2569,$,$); +#2574=IFCCLASSIFICATIONREFERENCE($,'23-13 41 13 19','Self Adhering Sheet Flexible Roof Flashings',#2569,$,$); +#2575=IFCCLASSIFICATIONREFERENCE($,'23-13 41 13 21','Roof Vent Flashings',#2569,$,$); +#2576=IFCCLASSIFICATIONREFERENCE($,'23-13 41 13 23','Roof Flashing Drip Caps',#2569,$,$); +#2577=IFCCLASSIFICATIONREFERENCE($,'23-13 41 13 25','Roof Penetration Flashings',#2569,$,$); +#2578=IFCCLASSIFICATIONREFERENCE($,'23-13 41 15','Roof Expansion Joints',#2561,$,$); +#2579=IFCCLASSIFICATIONREFERENCE($,'23-13 41 17','Roof Vents',#2561,$,$); +#2580=IFCCLASSIFICATIONREFERENCE($,'23-13 41 17 11','Roof Relief Vents',#2579,$,$); +#2581=IFCCLASSIFICATIONREFERENCE($,'23-13 41 17 13','Roof Ridge Vents',#2579,$,$); +#2582=IFCCLASSIFICATIONREFERENCE($,'23-13 41 17 15','Roof Smoke Vents',#2579,$,$); +#2583=IFCCLASSIFICATIONREFERENCE($,'23-13 41 17 17','Gravity Roof Vents',#2579,$,$); +#2584=IFCCLASSIFICATIONREFERENCE($,'23-13 41 17 19','Automatic Roof Vents',#2579,$,$); +#2585=IFCCLASSIFICATIONREFERENCE($,'23-13 41 17 21','Fire Vents',#2579,$,$); +#2586=IFCCLASSIFICATIONREFERENCE($,'23-13 41 19','Roof Walkways',#2561,$,$); +#2587=IFCCLASSIFICATIONREFERENCE($,'23-13 41 19 11','Roof Pavers',#2586,$,$); +#2588=IFCCLASSIFICATIONREFERENCE($,'23-13 41 19 11 11','Precast Concrete Roof Pavers',#2587,$,$); +#2589=IFCCLASSIFICATIONREFERENCE($,'23-13 41 19 11 13','Pedestals Roof Pavers',#2587,$,$); +#2590=IFCCLASSIFICATIONREFERENCE($,'23-13 41 19 13','Roof Treads',#2586,$,$); +#2591=IFCCLASSIFICATIONREFERENCE($,'23-13 41 19 13 11','Rubber Roof Treads',#2590,$,$); +#2592=IFCCLASSIFICATIONREFERENCE($,'23-13 41 21','Roof Snow Guards',#2561,$,$); +#2593=IFCCLASSIFICATIONREFERENCE($,'23-13 41 23','Roof Piping Portals',#2561,$,$); +#2594=IFCCLASSIFICATIONREFERENCE($,'23-13 41 25','Roof Domes',#2561,$,$); +#2595=IFCCLASSIFICATIONREFERENCE($,'23-13 41 27','Roof Turrets',#2561,$,$); +#2596=IFCCLASSIFICATIONREFERENCE($,'23-13 41 29','Roof Lanterns',#2561,$,$); +#2597=IFCCLASSIFICATIONREFERENCE($,'23-13 41 31','Roof Curb',#2561,$,$); +#2598=IFCCLASSIFICATIONREFERENCE($,'23-13 41 31 11','Structural Roof Curb',#2597,$,$); +#2599=IFCCLASSIFICATIONREFERENCE($,'23-13 41 31 13','Acoustical Roof Curb',#2597,$,$); +#2600=IFCCLASSIFICATIONREFERENCE($,'23-13 41 31 15','Manufactured Roof Curbs',#2597,$,$); +#2601=IFCCLASSIFICATIONREFERENCE($,'23-13 41 33','Roof Gutters',#2561,$,$); +#2602=IFCCLASSIFICATIONREFERENCE($,'23-13 41 35','Roof Soffits',#2561,$,$); +#2603=IFCCLASSIFICATIONREFERENCE($,'23-13 41 37','Roof Splash Blocks',#2561,$,$); +#2604=IFCCLASSIFICATIONREFERENCE($,'23-13 41 39','Roof Drains',#2561,$,$); +#2605=IFCCLASSIFICATIONREFERENCE($,'23-13 41 39 11','Roof Downspouts',#2604,$,$); +#2606=IFCCLASSIFICATIONREFERENCE($,'23-13 41 39 13','Roof Drains With Strainer',#2604,$,$); +#2607=IFCCLASSIFICATIONREFERENCE($,'23-13 41 39 15','Roof Drains Without Strainer',#2604,$,$); +#2608=IFCCLASSIFICATIONREFERENCE($,'23-13 41 39 17','Eavestroughs',#2604,$,$); +#2609=IFCCLASSIFICATIONREFERENCE($,'23-13 41 39 17 11','Mechanical Fasteners for Downspouts',#2608,$,$); +#2610=IFCCLASSIFICATIONREFERENCE($,'23-13 41 39 17 13','Downspout Strainers',#2608,$,$); +#2611=IFCCLASSIFICATIONREFERENCE($,'23-13 41 39 19','Siphonic Roof Drains',#2604,$,$); +#2612=IFCCLASSIFICATIONREFERENCE($,'23-15 00 00','Interior and Finish Products',#1606,$,$); +#2613=IFCCLASSIFICATIONREFERENCE($,'23-15 11 00','Space Division Products',#2612,$,$); +#2614=IFCCLASSIFICATIONREFERENCE($,'23-15 11 11','Fixed Partitions',#2613,$,$); +#2615=IFCCLASSIFICATIONREFERENCE($,'23-15 11 11 11','Gypsum Board Fixed Partitions',#2614,$,$); +#2616=IFCCLASSIFICATIONREFERENCE($,'23-15 11 11 11 11','Metal Framed Gypsum Board Fixed Partitions',#2615,$,$); +#2617=IFCCLASSIFICATIONREFERENCE($,'23-15 11 11 11 13','Wood Framed Gypsum Board Fixed Partitions',#2615,$,$); +#2618=IFCCLASSIFICATIONREFERENCE($,'23-15 11 11 13','Plaster Fixed Partitions',#2614,$,$); +#2619=IFCCLASSIFICATIONREFERENCE($,'23-15 11 11 13 11','Gypsum Plaster Fixed Partitions',#2618,$,$); +#2620=IFCCLASSIFICATIONREFERENCE($,'23-15 11 11 13 13','Portland Cement Plaster Fixed Partitions',#2618,$,$); +#2621=IFCCLASSIFICATIONREFERENCE($,'23-15 11 11 13 15','Metal Framed Plaster Fixed Partitions',#2618,$,$); +#2622=IFCCLASSIFICATIONREFERENCE($,'23-15 11 11 13 17','Wood Framed Plaster Fixed Partitions',#2618,$,$); +#2623=IFCCLASSIFICATIONREFERENCE($,'23-15 11 11 15','Masonry Fixed Partitions',#2614,$,$); +#2624=IFCCLASSIFICATIONREFERENCE($,'23-15 11 13','Demountable Partitions',#2613,$,$); +#2625=IFCCLASSIFICATIONREFERENCE($,'23-15 11 13 11','General Demountable Partitions',#2624,$,$); +#2626=IFCCLASSIFICATIONREFERENCE($,'23-15 11 13 11 11','Demountable Partitions Component',#2625,$,$); +#2627=IFCCLASSIFICATIONREFERENCE($,'23-15 11 13 11 11 11','Partition Frames',#2626,$,$); +#2628=IFCCLASSIFICATIONREFERENCE($,'23-15 11 13 11 11 13','Partition Infill Panels',#2626,$,$); +#2629=IFCCLASSIFICATIONREFERENCE($,'23-15 11 13 11 11 15','Mechanical Fasteners for Partitions',#2626,$,$); +#2630=IFCCLASSIFICATIONREFERENCE($,'23-15 11 13 11 11 17','Joint Fillers and Tapes',#2626,$,$); +#2631=IFCCLASSIFICATIONREFERENCE($,'23-15 11 13 11 13','Gypsum Board Demountable Partitions',#2625,$,$); +#2632=IFCCLASSIFICATIONREFERENCE($,'23-15 11 13 11 15','Metal Demountable Partitions',#2625,$,$); +#2633=IFCCLASSIFICATIONREFERENCE($,'23-15 11 13 11 17','Wood Demountable Partitions',#2625,$,$); +#2634=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15','Sanitary Partitions and Cubicles',#2613,$,$); +#2635=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 11','Toilet Compartments and Urinal Screens',#2634,$,$); +#2636=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 11 11','Metal Toilet Compartment and Urinal Screens',#2635,$,$); +#2637=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 11 13','Plastic Laminate Toilet Compartment and Urinal Screens',#2635,$,$); +#2638=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 11 15','Plastic Toilet Compartment and Urinal Screens',#2635,$,$); +#2639=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 11 17','Particleboard Toilet Compartment and Urinal Screens',#2635,$,$); +#2640=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 11 19','Stone Toilet Compartment and Urinal Screens',#2635,$,$); +#2641=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 13','Shower and Dressing Compartments',#2634,$,$); +#2642=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 13 11','Metal Shower and Dressing Compartments',#2641,$,$); +#2643=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 13 13','Plastic Laminate Shower and Dressing Compartments',#2641,$,$); +#2644=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 13 15','Plastic Shower and Dressing Compartments',#2641,$,$); +#2645=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 13 17','Particleboard Shower and Dressing Compartments',#2641,$,$); +#2646=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 13 19','Stone Shower and Dressing Compartments',#2641,$,$); +#2647=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 15','Cubicles',#2634,$,$); +#2648=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 15 11','Cubicle Curtains',#2647,$,$); +#2649=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 15 13','Cubicle Track and Hardware',#2647,$,$); +#2650=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 17','Storage Wall Partitions and Compartments',#2634,$,$); +#2651=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 17 11','Wire Mesh Partitions',#2650,$,$); +#2652=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 19','Modular Corridor Linings',#2634,$,$); +#2653=IFCCLASSIFICATIONREFERENCE($,'23-15 11 15 21','Combined Partitions and Ceilings',#2634,$,$); +#2654=IFCCLASSIFICATIONREFERENCE($,'23-15 11 17','Operable Partitions',#2613,$,$); +#2655=IFCCLASSIFICATIONREFERENCE($,'23-15 11 17 11','Horizontally Sliding Partitions',#2654,$,$); +#2656=IFCCLASSIFICATIONREFERENCE($,'23-15 11 17 13','Folding Panel Partitions',#2654,$,$); +#2657=IFCCLASSIFICATIONREFERENCE($,'23-15 11 17 15','Accordion Folding Partitions',#2654,$,$); +#2658=IFCCLASSIFICATIONREFERENCE($,'23-15 11 17 17','Coiling Partitions',#2654,$,$); +#2659=IFCCLASSIFICATIONREFERENCE($,'23-15 11 17 19','Vertically Sliding Room Dividers',#2654,$,$); +#2660=IFCCLASSIFICATIONREFERENCE($,'23-15 13 00','Multi-Function Interior Coverings, Claddings, Linings',#2612,$,$); +#2661=IFCCLASSIFICATIONREFERENCE($,'23-15 13 11','Multi Function Interior Claddings',#2660,$,$); +#2662=IFCCLASSIFICATIONREFERENCE($,'23-15 13 13','Interior Wall and Ceiling Cladding',#2660,$,$); +#2663=IFCCLASSIFICATIONREFERENCE($,'23-15 13 15','Interior Siding',#2660,$,$); +#2664=IFCCLASSIFICATIONREFERENCE($,'23-15 13 15 11','Metal Interior Siding',#2663,$,$); +#2665=IFCCLASSIFICATIONREFERENCE($,'23-15 13 15 13','Composition Interior Siding',#2663,$,$); +#2666=IFCCLASSIFICATIONREFERENCE($,'23-15 13 15 15','Mineral Fiber Cement Interior Siding',#2663,$,$); +#2667=IFCCLASSIFICATIONREFERENCE($,'23-15 13 15 17','Plastic Interior Siding',#2663,$,$); +#2668=IFCCLASSIFICATIONREFERENCE($,'23-15 13 15 19','Wood Interior Siding',#2663,$,$); +#2669=IFCCLASSIFICATIONREFERENCE($,'23-15 13 17','Multi Function Interior Linings',#2660,$,$); +#2670=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19','Wall Panels',#2660,$,$); +#2671=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19 11','Metal Wall Panels',#2670,$,$); +#2672=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19 13','Plastic Wall Panels',#2670,$,$); +#2673=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19 15','Wood Wall Panels',#2670,$,$); +#2674=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19 17','Composite Wall Panels',#2670,$,$); +#2675=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19 19','Faced Wall Panels',#2670,$,$); +#2676=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19 21','Aggregate Coated Wall Panels',#2670,$,$); +#2677=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19 23','Porcelain Enameled Faced Wall Panels',#2670,$,$); +#2678=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19 25','Tile Faced Wall Panels',#2670,$,$); +#2679=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19 27','Fiber Reinforced Cementitious Wall Panels',#2670,$,$); +#2680=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19 29','Glass Fiber Reinforced Cementitious Wall Panels',#2670,$,$); +#2681=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19 31','Miner Fiber Reinforced Cementitious Wall Panels',#2670,$,$); +#2682=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19 33','Flexible Wood Wall Sheets',#2670,$,$); +#2683=IFCCLASSIFICATIONREFERENCE($,'23-15 13 19 35','Acoustical Wall Treatment',#2670,$,$); +#2684=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21','Ceiling Panels',#2660,$,$); +#2685=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21 11','Metal Ceiling Panels',#2684,$,$); +#2686=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21 13','Plastic Ceiling Panels',#2684,$,$); +#2687=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21 15','Wood Ceiling Panels',#2684,$,$); +#2688=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21 17','Composite Ceiling Panels',#2684,$,$); +#2689=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21 19','Faced Ceiling Panels',#2684,$,$); +#2690=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21 21','Aggregate Coated Ceiling Panels',#2684,$,$); +#2691=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21 23','Porcelain Enameled Faced Ceiling Panels',#2684,$,$); +#2692=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21 25','Tile Faced Ceiling Panels',#2684,$,$); +#2693=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21 27','Fiber Reinforced Cementitious Ceiling Panels',#2684,$,$); +#2694=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21 29','Glass Fiber Reinforced Cementitious Ceiling Panels',#2684,$,$); +#2695=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21 31','Miner Fiber Reinforced Cementitious Ceiling Panels',#2684,$,$); +#2696=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21 33','Flexible Wood Ceiling Sheets',#2684,$,$); +#2697=IFCCLASSIFICATIONREFERENCE($,'23-15 13 21 35','Acoustical Ceiling Treatment',#2684,$,$); +#2698=IFCCLASSIFICATIONREFERENCE($,'23-15 13 23','Interior Plasters',#2660,$,$); +#2699=IFCCLASSIFICATIONREFERENCE($,'23-15 13 25','Preformed Interior Casings',#2660,$,$); +#2700=IFCCLASSIFICATIONREFERENCE($,'23-15 15 00','Wall Coverings, Claddings, Linings',#2612,$,$); +#2701=IFCCLASSIFICATIONREFERENCE($,'23-15 15 11','Wall Cladding Sections',#2700,$,$); +#2702=IFCCLASSIFICATIONREFERENCE($,'23-15 15 11 11','Metal Wall Cladding Sections',#2701,$,$); +#2703=IFCCLASSIFICATIONREFERENCE($,'23-15 15 11 13','Wood Wall Cladding Sections',#2701,$,$); +#2704=IFCCLASSIFICATIONREFERENCE($,'23-15 15 11 15','Plastics Wall Cladding Sections',#2701,$,$); +#2705=IFCCLASSIFICATIONREFERENCE($,'23-15 15 11 17','Other Wall Cladding Sections',#2701,$,$); +#2706=IFCCLASSIFICATIONREFERENCE($,'23-15 15 13','Wall Tiles',#2700,$,$); +#2707=IFCCLASSIFICATIONREFERENCE($,'23-15 15 13 11','Natural Stone Wall Tiles',#2706,$,$); +#2708=IFCCLASSIFICATIONREFERENCE($,'23-15 15 13 13','Reconstituted Stone Wall Tiles',#2706,$,$); +#2709=IFCCLASSIFICATIONREFERENCE($,'23-15 15 13 15','Cementitious Wall Tiles',#2706,$,$); +#2710=IFCCLASSIFICATIONREFERENCE($,'23-15 15 13 17','Clay Based Wall Tiles',#2706,$,$); +#2711=IFCCLASSIFICATIONREFERENCE($,'23-15 15 13 19','Metal Wall Tiles',#2706,$,$); +#2712=IFCCLASSIFICATIONREFERENCE($,'23-15 15 13 21','Vegetable Based Wall Tiles',#2706,$,$); +#2713=IFCCLASSIFICATIONREFERENCE($,'23-15 15 13 23','Plastics Wall Tiles',#2706,$,$); +#2714=IFCCLASSIFICATIONREFERENCE($,'23-15 15 13 25','Other Wall Tiles',#2706,$,$); +#2715=IFCCLASSIFICATIONREFERENCE($,'23-15 15 15','Wall Cladding Panels',#2700,$,$); +#2716=IFCCLASSIFICATIONREFERENCE($,'23-15 15 15 11','Wall Stone Facing',#2715,$,$); +#2717=IFCCLASSIFICATIONREFERENCE($,'23-15 15 15 13','Cementitious Wall Cladding Panels',#2715,$,$); +#2718=IFCCLASSIFICATIONREFERENCE($,'23-15 15 15 13 11','Precast Concrete Wall Cladding Panels',#2717,$,$); +#2719=IFCCLASSIFICATIONREFERENCE($,'23-15 15 15 15','Metal Wall Cladding Panels',#2715,$,$); +#2720=IFCCLASSIFICATIONREFERENCE($,'23-15 15 15 17','Wood Based Wall Cladding Panels',#2715,$,$); +#2721=IFCCLASSIFICATIONREFERENCE($,'23-15 15 15 19','Plastic Wall Cladding Panels',#2715,$,$); +#2722=IFCCLASSIFICATIONREFERENCE($,'23-15 15 15 19 11','Plastic Wall Cladding Blocks',#2721,$,$); +#2723=IFCCLASSIFICATIONREFERENCE($,'23-15 15 15 21','Other Wall Cladding Panels',#2715,$,$); +#2724=IFCCLASSIFICATIONREFERENCE($,'23-15 15 17','Wall Cladding Sheets',#2700,$,$); +#2725=IFCCLASSIFICATIONREFERENCE($,'23-15 15 17 11','Fiber Based Wall Cladding Sheets',#2724,$,$); +#2726=IFCCLASSIFICATIONREFERENCE($,'23-15 15 17 13','Metal Wall Cladding Sheets',#2724,$,$); +#2727=IFCCLASSIFICATIONREFERENCE($,'23-15 15 17 15','Plastic Wall Cladding Sheets',#2724,$,$); +#2728=IFCCLASSIFICATIONREFERENCE($,'23-15 15 17 17','Fiberglass Reinforced Panels',#2724,$,$); +#2729=IFCCLASSIFICATIONREFERENCE($,'23-15 15 19','Wall Coverings',#2700,$,$); +#2730=IFCCLASSIFICATIONREFERENCE($,'23-15 15 19 11','Wallpaper',#2729,$,$); +#2731=IFCCLASSIFICATIONREFERENCE($,'23-15 15 19 13','Wall Fabrics',#2729,$,$); +#2732=IFCCLASSIFICATIONREFERENCE($,'23-15 15 19 15','Plastic Wall Coverings',#2729,$,$); +#2733=IFCCLASSIFICATIONREFERENCE($,'23-15 15 19 17','Cork Wall Covering',#2729,$,$); +#2734=IFCCLASSIFICATIONREFERENCE($,'23-15 15 19 19','Vinyl Coated Fabric Wall Covering',#2729,$,$); +#2735=IFCCLASSIFICATIONREFERENCE($,'23-15 15 19 21','Vinyl Wall Covering',#2729,$,$); +#2736=IFCCLASSIFICATIONREFERENCE($,'23-15 15 19 23','Wall Carpet',#2729,$,$); +#2737=IFCCLASSIFICATIONREFERENCE($,'23-15 15 19 25','Wall Veneers',#2729,$,$); +#2738=IFCCLASSIFICATIONREFERENCE($,'23-15 15 21','Wall Blocks',#2700,$,$); +#2739=IFCCLASSIFICATIONREFERENCE($,'23-15 15 23','Wall Linings',#2700,$,$); +#2740=IFCCLASSIFICATIONREFERENCE($,'23-15 15 25','Wall Finish Coatings',#2700,$,$); +#2741=IFCCLASSIFICATIONREFERENCE($,'23-15 15 27','Renders',#2700,$,$); +#2742=IFCCLASSIFICATIONREFERENCE($,'23-15 15 29','Acoustical Wall Finishes',#2700,$,$); +#2743=IFCCLASSIFICATIONREFERENCE($,'23-15 15 31','Wall Specialties and Trim',#2700,$,$); +#2744=IFCCLASSIFICATIONREFERENCE($,'23-15 15 31 11','Wall Pilasters',#2743,$,$); +#2745=IFCCLASSIFICATIONREFERENCE($,'23-15 15 31 13','Wall Niches',#2743,$,$); +#2746=IFCCLASSIFICATIONREFERENCE($,'23-15 15 31 15','Wall Moldings',#2743,$,$); +#2747=IFCCLASSIFICATIONREFERENCE($,'23-15 15 31 17','Renovating Wall Coverings',#2743,$,$); +#2748=IFCCLASSIFICATIONREFERENCE($,'23-15 15 31 19','Renovating Wall Claddings',#2743,$,$); +#2749=IFCCLASSIFICATIONREFERENCE($,'23-15 15 33','Wall Finish Restoration Products',#2700,$,$); +#2750=IFCCLASSIFICATIONREFERENCE($,'23-15 15 35','Security Wall Protection Products',#2700,$,$); +#2751=IFCCLASSIFICATIONREFERENCE($,'23-15 15 35 11','Blast Resistant Wall Exteriors',#2750,$,$); +#2752=IFCCLASSIFICATIONREFERENCE($,'23-15 15 35 13','Blast Resistant Wall Interiors',#2750,$,$); +#2753=IFCCLASSIFICATIONREFERENCE($,'23-15 17 00','Floor Coverings',#2612,$,$); +#2754=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11','Flooring Specialties and Accessories',#2753,$,$); +#2755=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 11','Floor Toppings',#2754,$,$); +#2756=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 11 11','Concrete Floor Toppings',#2755,$,$); +#2757=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 13','Floor Underlayments',#2754,$,$); +#2758=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 13 11','Cementitious Floor Underlayments',#2757,$,$); +#2759=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 13 11 11','Gypsum Floor Underlayments',#2758,$,$); +#2760=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 13 11 13','Portland Cement Floor Underlayments',#2758,$,$); +#2761=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 13 13','Acoustical Underlayments',#2757,$,$); +#2762=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 13 15','Crack Prevention Mat Underlayments',#2757,$,$); +#2763=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 15','Floor Treatment Products',#2754,$,$); +#2764=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 15 11','Floor Sealers',#2763,$,$); +#2765=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 15 13','Floor Hardeners',#2763,$,$); +#2766=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 15 15','Slip Resistant Floor Treatment',#2763,$,$); +#2767=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 15 17','Static Resistant Floor Treatment',#2763,$,$); +#2768=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 15 19','Acid Resistant Floor Treatment',#2763,$,$); +#2769=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 17','Floor Base and Accessories',#2754,$,$); +#2770=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 17 11','Base and Accessories for Floor Coverings',#2769,$,$); +#2771=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 17 13','Acoustic Floor Mountings',#2769,$,$); +#2772=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 19','Floor Mats and Grilles',#2754,$,$); +#2773=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 19 11','Floor Mats',#2772,$,$); +#2774=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 19 13','Floor Grilles',#2772,$,$); +#2775=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 19 15','Floor Gratings',#2772,$,$); +#2776=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 21','Flooring Restoration Products',#2754,$,$); +#2777=IFCCLASSIFICATIONREFERENCE($,'23-15 17 11 21 11','Bamboo',#2776,$,$); +#2778=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13','Floor Covering Strips, Tiles, Blocks, and Slabs',#2753,$,$); +#2779=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 11','Wood Flooring',#2778,$,$); +#2780=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 11 11','Cushioned Wood Flooring Assemblies',#2779,$,$); +#2781=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 11 13','Mastic Set Wood Flooring Assemblies',#2779,$,$); +#2782=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 11 15','Resilient Wood Flooring Assemblies',#2779,$,$); +#2783=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 11 17','Wood Athletic Flooring',#2779,$,$); +#2784=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 11 19','Wood Block Flooring',#2779,$,$); +#2785=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 11 21','Wood Composition Flooring',#2779,$,$); +#2786=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 11 23','Wood Parquet Flooring',#2779,$,$); +#2787=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 11 25','Wood Strip Flooring',#2779,$,$); +#2788=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 13','Tile Flooring',#2778,$,$); +#2789=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 13 11','Clay Based Flooring',#2788,$,$); +#2790=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 13 13','Ceramic Tile Flooring',#2788,$,$); +#2791=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 13 13 11','Ceramic Mosaic Tile Flooring',#2790,$,$); +#2792=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 13 13 13','Conductive Tile Flooring',#2790,$,$); +#2793=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 13 15','Quarry Tile Flooring',#2788,$,$); +#2794=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 13 17','Chemical Resistant Quarry Tile Flooring',#2788,$,$); +#2795=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 13 17 11','Porcelain Tile Flooring',#2794,$,$); +#2796=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 13 17 13','Glass Mosaic Tile Flooring',#2794,$,$); +#2797=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 13 17 15','Plastic Tile Flooring',#2794,$,$); +#2798=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 13 17 17','Metal Tile Flooring',#2794,$,$); +#2799=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 13 17 19','Natural Cut Stone Tile Flooring',#2794,$,$); +#2800=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 13 17 21','Tile Flooring Restoration Products',#2794,$,$); +#2801=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 15','Terrazzo Flooring',#2778,$,$); +#2802=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 15 11','Portland Cement Terrazzo Flooring',#2801,$,$); +#2803=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 15 13','Precast Terrazzo Flooring',#2801,$,$); +#2804=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 15 15','Conductive Terrazzo Flooring',#2801,$,$); +#2805=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 15 17','Plastic matrix Terrazzo Flooring',#2801,$,$); +#2806=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 15 19','Terrazzo Flooring Restoration Products',#2801,$,$); +#2807=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 17','Masonry Flooring',#2778,$,$); +#2808=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 17 11','Brick Flooring',#2807,$,$); +#2809=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 17 11 11','Chemical Resistant Brick Flooring',#2808,$,$); +#2810=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 17 13','Stone Flooring',#2807,$,$); +#2811=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 17 15','Other Masonry Flooring',#2807,$,$); +#2812=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 19','Precast Tile and Slab Flooring',#2778,$,$); +#2813=IFCCLASSIFICATIONREFERENCE($,'23-15 17 13 21','Metal Flooring',#2778,$,$); +#2814=IFCCLASSIFICATIONREFERENCE($,'23-15 17 15','Resilient Flooring',#2753,$,$); +#2815=IFCCLASSIFICATIONREFERENCE($,'23-15 17 15 11','Cork Flooring',#2814,$,$); +#2816=IFCCLASSIFICATIONREFERENCE($,'23-15 17 15 13','Plastic Flooring',#2814,$,$); +#2817=IFCCLASSIFICATIONREFERENCE($,'23-15 17 15 15','Rubber Flooring',#2814,$,$); +#2818=IFCCLASSIFICATIONREFERENCE($,'23-15 17 15 17','Linoleum Flooring',#2814,$,$); +#2819=IFCCLASSIFICATIONREFERENCE($,'23-15 17 15 19','Mechanical Fasteners for Resilient Floor Coverings',#2814,$,$); +#2820=IFCCLASSIFICATIONREFERENCE($,'23-15 17 15 19 11','Floor Clips',#2819,$,$); +#2821=IFCCLASSIFICATIONREFERENCE($,'23-15 17 15 19 13','Carpet Grippers',#2819,$,$); +#2822=IFCCLASSIFICATIONREFERENCE($,'23-15 17 15 19 15','Stair Rods',#2819,$,$); +#2823=IFCCLASSIFICATIONREFERENCE($,'23-15 17 15 21','Other Resilient Flooring',#2814,$,$); +#2824=IFCCLASSIFICATIONREFERENCE($,'23-15 17 17','Carpet Flooring',#2753,$,$); +#2825=IFCCLASSIFICATIONREFERENCE($,'23-15 17 17 11','Carpet Cushions',#2824,$,$); +#2826=IFCCLASSIFICATIONREFERENCE($,'23-15 17 17 13','Carpet Tiles',#2824,$,$); +#2827=IFCCLASSIFICATIONREFERENCE($,'23-15 17 17 15','Indoor Carpet Flooring',#2824,$,$); +#2828=IFCCLASSIFICATIONREFERENCE($,'23-15 17 17 17','Outdoor Carpet Flooring',#2824,$,$); +#2829=IFCCLASSIFICATIONREFERENCE($,'23-15 17 17 19','Sheet Carpet Flooring',#2824,$,$); +#2830=IFCCLASSIFICATIONREFERENCE($,'23-15 17 19','Preformed Flooring Equipment Systems',#2753,$,$); +#2831=IFCCLASSIFICATIONREFERENCE($,'23-15 17 19 11','Floating Floors',#2830,$,$); +#2832=IFCCLASSIFICATIONREFERENCE($,'23-15 17 19 13','Portable Floors',#2830,$,$); +#2833=IFCCLASSIFICATIONREFERENCE($,'23-15 17 19 15','Convertible Floors',#2830,$,$); +#2834=IFCCLASSIFICATIONREFERENCE($,'23-15 17 19 17','Gymnasium or Dance Flooring',#2830,$,$); +#2835=IFCCLASSIFICATIONREFERENCE($,'23-15 17 21','Access Flooring Components',#2753,$,$); +#2836=IFCCLASSIFICATIONREFERENCE($,'23-15 17 21 11','Access Floor Frames',#2835,$,$); +#2837=IFCCLASSIFICATIONREFERENCE($,'23-15 17 21 13','Access Floor Infill Panels',#2835,$,$); +#2838=IFCCLASSIFICATIONREFERENCE($,'23-15 17 23','Rigid Grid Access Flooring',#2753,$,$); +#2839=IFCCLASSIFICATIONREFERENCE($,'23-15 17 25','Snap On Stringer Access Flooring',#2753,$,$); +#2840=IFCCLASSIFICATIONREFERENCE($,'23-15 17 27','Stringerless Access Flooring',#2753,$,$); +#2841=IFCCLASSIFICATIONREFERENCE($,'23-15 17 29','Floor Finishing Coatings',#2753,$,$); +#2842=IFCCLASSIFICATIONREFERENCE($,'23-15 17 29 11','Industrial Floor Coatings',#2841,$,$); +#2843=IFCCLASSIFICATIONREFERENCE($,'23-15 17 29 13','Fluid Applied Flooring',#2841,$,$); +#2844=IFCCLASSIFICATIONREFERENCE($,'23-15 17 29 13 11','Elastomeric Liquid Flooring',#2843,$,$); +#2845=IFCCLASSIFICATIONREFERENCE($,'23-15 17 29 13 13','Epoxy Marble Chip Flooring',#2843,$,$); +#2846=IFCCLASSIFICATIONREFERENCE($,'23-15 17 29 13 15','Magnesium Oxychoride Flooring',#2843,$,$); +#2847=IFCCLASSIFICATIONREFERENCE($,'23-15 17 29 13 17','Mastic Fills Flooring',#2843,$,$); +#2848=IFCCLASSIFICATIONREFERENCE($,'23-15 17 29 13 19','Resinous Flooring',#2843,$,$); +#2849=IFCCLASSIFICATIONREFERENCE($,'23-15 17 29 13 21','Seamless Quartz Flooring',#2843,$,$); +#2850=IFCCLASSIFICATIONREFERENCE($,'23-15 19 00','Ceiling Coverings, Claddings, and Linings',#2612,$,$); +#2851=IFCCLASSIFICATIONREFERENCE($,'23-15 19 11','Ceiling Baffles',#2850,$,$); +#2852=IFCCLASSIFICATIONREFERENCE($,'23-15 19 13','Ceiling Clouds',#2850,$,$); +#2853=IFCCLASSIFICATIONREFERENCE($,'23-15 19 15','Ceiling Tiles, Panels, Strips, and Sections',#2850,$,$); +#2854=IFCCLASSIFICATIONREFERENCE($,'23-15 19 15 11','Ceiling Tiles',#2853,$,$); +#2855=IFCCLASSIFICATIONREFERENCE($,'23-15 19 15 11 11','Acoustical Ceiling Tile',#2854,$,$); +#2856=IFCCLASSIFICATIONREFERENCE($,'23-15 19 15 13','Ceiling Panels',#2853,$,$); +#2857=IFCCLASSIFICATIONREFERENCE($,'23-15 19 15 13 11','Acoustical Ceiling Panels',#2856,$,$); +#2858=IFCCLASSIFICATIONREFERENCE($,'23-15 19 15 13 13','Mirror Ceiling Panels',#2856,$,$); +#2859=IFCCLASSIFICATIONREFERENCE($,'23-15 19 15 13 15','Curved Ceiling Panels',#2856,$,$); +#2860=IFCCLASSIFICATIONREFERENCE($,'23-15 19 15 13 17','Metal Ceiling Panels',#2856,$,$); +#2861=IFCCLASSIFICATIONREFERENCE($,'23-15 19 15 15','Ceiling Covering Strips',#2853,$,$); +#2862=IFCCLASSIFICATIONREFERENCE($,'23-15 19 15 15 11','Linear Metal Ceiling Covering Strips',#2861,$,$); +#2863=IFCCLASSIFICATIONREFERENCE($,'23-15 19 15 15 13','Linear Wood Ceiling Covering Strips',#2861,$,$); +#2864=IFCCLASSIFICATIONREFERENCE($,'23-15 19 15 17','Ceiling Covering Sections',#2853,$,$); +#2865=IFCCLASSIFICATIONREFERENCE($,'23-15 19 15 17 11','Suspended Decorative Ceiling Grids',#2864,$,$); +#2866=IFCCLASSIFICATIONREFERENCE($,'23-15 19 17','Ceiling Finishing Coatings',#2850,$,$); +#2867=IFCCLASSIFICATIONREFERENCE($,'23-15 19 17 11','Textured Ceilings',#2866,$,$); +#2868=IFCCLASSIFICATIONREFERENCE($,'23-15 19 17 11 11','Gypsum Panel Textured Ceilings',#2867,$,$); +#2869=IFCCLASSIFICATIONREFERENCE($,'23-15 19 17 11 13','Metal Panel Textured Ceilings',#2867,$,$); +#2870=IFCCLASSIFICATIONREFERENCE($,'23-15 19 19','Ceiling Specialties and Accessories',#2850,$,$); +#2871=IFCCLASSIFICATIONREFERENCE($,'23-15 19 19 11','Roses Ceiling Centerpieces',#2870,$,$); +#2872=IFCCLASSIFICATIONREFERENCE($,'23-15 19 19 13','Ceiling Coving',#2870,$,$); +#2873=IFCCLASSIFICATIONREFERENCE($,'23-15 19 19 15','Ceiling Cornices',#2870,$,$); +#2874=IFCCLASSIFICATIONREFERENCE($,'23-15 19 19 17','Ceiling Friezes',#2870,$,$); +#2875=IFCCLASSIFICATIONREFERENCE($,'23-15 19 19 19','Integral Speaking Panels',#2870,$,$); +#2876=IFCCLASSIFICATIONREFERENCE($,'23-15 19 21','Ceiling Assembly Restoration Products',#2850,$,$); +#2877=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23','Ceilings',#2850,$,$); +#2878=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11','Suspended Ceilings',#2877,$,$); +#2879=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 11','Suspended Ceiling Components',#2878,$,$); +#2880=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 11 11','Suspended Ceilings, Suspension Assembly',#2879,$,$); +#2881=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 11 13','Suspended Ceilings, Panels and Tiles',#2879,$,$); +#2882=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 11 15','Suspended Ceilings, Grids',#2879,$,$); +#2883=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 11 17','Mechanical Fasteners for Suspended Ceilings',#2879,$,$); +#2884=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 13','Acoustical Ceilings',#2878,$,$); +#2885=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 13 11','Metal Pan Acoustical Ceilings',#2884,$,$); +#2886=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 13 13','Acoustical Panel Ceilings',#2884,$,$); +#2887=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 13 15','Acoustical Tile Ceilings',#2884,$,$); +#2888=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 15','Specialty Ceilings',#2878,$,$); +#2889=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 15 11','Integrated Ceilings',#2888,$,$); +#2890=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 15 13','Linear Ceilings',#2888,$,$); +#2891=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 15 13 11','Metal Linear Ceilings',#2890,$,$); +#2892=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 15 13 13','Wood Linear Ceilings',#2890,$,$); +#2893=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 15 15','Luminous Ceilings',#2888,$,$); +#2894=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 15 17','Mirror Panel Ceilings',#2888,$,$); +#2895=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 15 19','Textured Ceilings',#2888,$,$); +#2896=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 15 21','Suspended Decorative Grids',#2888,$,$); +#2897=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 11 15 23','Clean Room Ceilings',#2888,$,$); +#2898=IFCCLASSIFICATIONREFERENCE($,'23-15 19 23 13','Stretched Fabric Ceilings',#2877,$,$); +#2899=IFCCLASSIFICATIONREFERENCE($,'23-15 21 00','Surface Applied Coatings',#2612,$,$); +#2900=IFCCLASSIFICATIONREFERENCE($,'23-15 21 11','Paints and Varnishes',#2899,$,$); +#2901=IFCCLASSIFICATIONREFERENCE($,'23-15 21 11 11','General Purpose Paints and Varnishes',#2900,$,$); +#2902=IFCCLASSIFICATIONREFERENCE($,'23-15 21 11 11 11','Solvent Based General Purpose Paints and Varnishes',#2901,$,$); +#2903=IFCCLASSIFICATIONREFERENCE($,'23-15 21 11 11 13','Water Based General Purpose Paints and Varnishes',#2901,$,$); +#2904=IFCCLASSIFICATIONREFERENCE($,'23-15 21 11 13','Textured Paints',#2900,$,$); +#2905=IFCCLASSIFICATIONREFERENCE($,'23-15 21 11 13 11','Solvent Based Textured Paints',#2904,$,$); +#2906=IFCCLASSIFICATIONREFERENCE($,'23-15 21 11 13 13','Water Based Textured Paints',#2904,$,$); +#2907=IFCCLASSIFICATIONREFERENCE($,'23-15 21 13','Paints for Particular Applications',#2899,$,$); +#2908=IFCCLASSIFICATIONREFERENCE($,'23-15 21 13 11','Corrosion Prevention Paints',#2907,$,$); +#2909=IFCCLASSIFICATIONREFERENCE($,'23-15 21 13 13','Solar Reflective Paints',#2907,$,$); +#2910=IFCCLASSIFICATIONREFERENCE($,'23-15 21 13 15','Fluorescent Paints',#2907,$,$); +#2911=IFCCLASSIFICATIONREFERENCE($,'23-15 21 13 17','Line Paints',#2907,$,$); +#2912=IFCCLASSIFICATIONREFERENCE($,'23-15 21 13 19','Roadway Marking Paints',#2907,$,$); +#2913=IFCCLASSIFICATIONREFERENCE($,'23-15 21 13 21','Swimming Pool Paints',#2907,$,$); +#2914=IFCCLASSIFICATIONREFERENCE($,'23-15 21 13 23','Coatings for Concrete and Masonry',#2907,$,$); +#2915=IFCCLASSIFICATIONREFERENCE($,'23-15 21 13 25','Mold/Mildew Resistant Coatings',#2907,$,$); +#2916=IFCCLASSIFICATIONREFERENCE($,'23-15 21 15','Powder Coating Services',#2899,$,$); +#2917=IFCCLASSIFICATIONREFERENCE($,'23-15 21 15 11','Factory Applied Metal Powder Coatings',#2916,$,$); +#2918=IFCCLASSIFICATIONREFERENCE($,'23-15 21 17','Inorganic Metal Treatments',#2899,$,$); +#2919=IFCCLASSIFICATIONREFERENCE($,'23-15 21 17 11','Galvanized Coatings',#2918,$,$); +#2920=IFCCLASSIFICATIONREFERENCE($,'23-15 21 17 13','Anodized Coatings',#2918,$,$); +#2921=IFCCLASSIFICATIONREFERENCE($,'23-15 21 17 15','Electro Plated Coatings',#2918,$,$); +#2922=IFCCLASSIFICATIONREFERENCE($,'23-15 21 17 17','Vitreous Enameling',#2918,$,$); +#2923=IFCCLASSIFICATIONREFERENCE($,'23-15 21 19','Stains and Decorative Surface Impregnations',#2899,$,$); +#2924=IFCCLASSIFICATIONREFERENCE($,'23-15 21 19 11','Decorative Wood Conservation Products',#2923,$,$); +#2925=IFCCLASSIFICATIONREFERENCE($,'23-15 21 19 13','Stains',#2923,$,$); +#2926=IFCCLASSIFICATIONREFERENCE($,'23-15 21 19 13 11','Opaque Stains',#2925,$,$); +#2927=IFCCLASSIFICATIONREFERENCE($,'23-15 21 19 13 11 11','Exterior Opaque Stains',#2926,$,$); +#2928=IFCCLASSIFICATIONREFERENCE($,'23-15 21 19 13 11 13','Interior Opaque Stains',#2926,$,$); +#2929=IFCCLASSIFICATIONREFERENCE($,'23-15 21 19 13 13','Transparent Stains',#2925,$,$); +#2930=IFCCLASSIFICATIONREFERENCE($,'23-15 21 19 13 13 11','Exterior Transparent Stains',#2929,$,$); +#2931=IFCCLASSIFICATIONREFERENCE($,'23-15 21 19 13 13 13','Interior Transparent Stains',#2929,$,$); +#2932=IFCCLASSIFICATIONREFERENCE($,'23-15 21 21','High Performance Coatings',#2899,$,$); +#2933=IFCCLASSIFICATIONREFERENCE($,'23-15 21 21 11','Abrasion Resistant Coatings',#2932,$,$); +#2934=IFCCLASSIFICATIONREFERENCE($,'23-15 21 21 13','Chemical Resistant Coatings',#2932,$,$); +#2935=IFCCLASSIFICATIONREFERENCE($,'23-15 21 21 15','Elastomeric Coatings',#2932,$,$); +#2936=IFCCLASSIFICATIONREFERENCE($,'23-15 21 21 17','Fire Resistant Coatings',#2932,$,$); +#2937=IFCCLASSIFICATIONREFERENCE($,'23-15 21 21 19','Graffiti Resistant Coatings',#2932,$,$); +#2938=IFCCLASSIFICATIONREFERENCE($,'23-15 21 21 21','High Building Coatings',#2932,$,$); +#2939=IFCCLASSIFICATIONREFERENCE($,'23-15 21 21 23','Intumescent Paints',#2932,$,$); +#2940=IFCCLASSIFICATIONREFERENCE($,'23-15 21 21 25','Marine Coatings',#2932,$,$); +#2941=IFCCLASSIFICATIONREFERENCE($,'23-15 21 21 27','Textured Plastic Coatings',#2932,$,$); +#2942=IFCCLASSIFICATIONREFERENCE($,'23-15 21 23','Protective Surface Impregnations',#2899,$,$); +#2943=IFCCLASSIFICATIONREFERENCE($,'23-15 21 23 11','Surface Consolidation Hardening Impregnations',#2942,$,$); +#2944=IFCCLASSIFICATIONREFERENCE($,'23-15 21 23 13','Impregnations Protecting from Biological Attack',#2942,$,$); +#2945=IFCCLASSIFICATIONREFERENCE($,'23-15 21 23 13 11','Wood Treatment Protecting from Biological Attack',#2944,$,$); +#2946=IFCCLASSIFICATIONREFERENCE($,'23-15 21 23 15','Impregnations Protecting from Fire',#2942,$,$); +#2947=IFCCLASSIFICATIONREFERENCE($,'23-15 21 23 15 11','Wood Treatment Protecting from Fire',#2946,$,$); +#2948=IFCCLASSIFICATIONREFERENCE($,'23-15 21 23 15 11 11','Fire Retardant Treatment',#2947,$,$); +#2949=IFCCLASSIFICATIONREFERENCE($,'23-15 21 23 17','Water Repellents',#2942,$,$); +#2950=IFCCLASSIFICATIONREFERENCE($,'23-15 21 23 17 11','Acrylic Water Repellents',#2949,$,$); +#2951=IFCCLASSIFICATIONREFERENCE($,'23-15 21 23 17 13','Silane Water Repellents',#2949,$,$); +#2952=IFCCLASSIFICATIONREFERENCE($,'23-15 21 23 17 15','Silicone Water Repellents',#2949,$,$); +#2953=IFCCLASSIFICATIONREFERENCE($,'23-15 21 23 17 17','Siloxane Water Repellents',#2949,$,$); +#2954=IFCCLASSIFICATIONREFERENCE($,'23-15 21 23 17 19','Stearate Water Repellents',#2949,$,$); +#2955=IFCCLASSIFICATIONREFERENCE($,'23-17 00 00','Openings, Passages, and Protection Products',#1606,$,$); +#2956=IFCCLASSIFICATIONREFERENCE($,'23-17 11 00','Doors',#2955,$,$); +#2957=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11','Door Components',#2956,$,$); +#2958=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 11','Door Frames',#2957,$,$); +#2959=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 13','Preassembled Door and Frame Units',#2957,$,$); +#2960=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 15','Door Fanlights',#2957,$,$); +#2961=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 17','Door Sections',#2957,$,$); +#2962=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 17 11','Structural Door Sections',#2961,$,$); +#2963=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 17 13','Door Cladding Sections',#2961,$,$); +#2964=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 19','Door Linings and Boards',#2957,$,$); +#2965=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 21','Door Renovation Sets',#2957,$,$); +#2966=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 23','Door Sidelites',#2957,$,$); +#2967=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 25','Door Accessories',#2957,$,$); +#2968=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 25 11','Door Peep Holes',#2967,$,$); +#2969=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 25 13','Door Buffers',#2967,$,$); +#2970=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 25 15','Door Stops',#2967,$,$); +#2971=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 25 17','Door Mail Openings',#2967,$,$); +#2972=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 25 19','Door Mail Slots',#2967,$,$); +#2973=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 25 21','Door Louvers',#2967,$,$); +#2974=IFCCLASSIFICATIONREFERENCE($,'23-17 11 11 25 23','Door Lights',#2967,$,$); +#2975=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13','Metal Doors',#2956,$,$); +#2976=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 11','Hollow Metal Doors',#2975,$,$); +#2977=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 13','Aluminum Doors',#2975,$,$); +#2978=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 13 11','Aluminum Screen Doors',#2977,$,$); +#2979=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 13 13','Aluminum Storm Doors',#2977,$,$); +#2980=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 15','Steel Doors',#2975,$,$); +#2981=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 15 11','Steel Screen Doors',#2980,$,$); +#2982=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 15 13','Steel Storm Doors',#2980,$,$); +#2983=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 17','Bronze Doors',#2975,$,$); +#2984=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 19','Sliding Metal Doors',#2975,$,$); +#2985=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 21','Folding Metal Doors',#2975,$,$); +#2986=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 23','Revolving Metal Doors',#2975,$,$); +#2987=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 25','Overhead Metal Doors',#2975,$,$); +#2988=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 25 11','Roller Shutter Overhead Metal Doors',#2987,$,$); +#2989=IFCCLASSIFICATIONREFERENCE($,'23-17 11 13 25 13','Sectional Overhead Metal Doors',#2987,$,$); +#2990=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15','Wood Doors',#2956,$,$); +#2991=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15 11','Carved Wood Doors',#2990,$,$); +#2992=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15 13','Flush Wood Doors',#2990,$,$); +#2993=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15 15','Clad Wood Doors',#2990,$,$); +#2994=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15 17','Prefinished Wood Doors',#2990,$,$); +#2995=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15 19','Stile and Rail Wood Doors',#2990,$,$); +#2996=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15 21','Wood Storm Doors',#2990,$,$); +#2997=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15 23','Wood Screen Doors',#2990,$,$); +#2998=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15 25','Sliding Wood Doors',#2990,$,$); +#2999=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15 27','Folding Wood Doors',#2990,$,$); +#3000=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15 29','Revolving Wood Doors',#2990,$,$); +#3001=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15 31','Overhead Wood Doors',#2990,$,$); +#3002=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15 31 11','Roller Shutter Overhead Wood Doors',#3001,$,$); +#3003=IFCCLASSIFICATIONREFERENCE($,'23-17 11 15 31 13','Sectional Overhead Wood Doors',#3001,$,$); +#3004=IFCCLASSIFICATIONREFERENCE($,'23-17 11 17','Plastic Doors',#2956,$,$); +#3005=IFCCLASSIFICATIONREFERENCE($,'23-17 11 17 11','Laminated Plastic Doors',#3004,$,$); +#3006=IFCCLASSIFICATIONREFERENCE($,'23-17 11 17 13','Solid Plastic Doors',#3004,$,$); +#3007=IFCCLASSIFICATIONREFERENCE($,'23-17 11 17 15','Plastic Storm Doors',#3004,$,$); +#3008=IFCCLASSIFICATIONREFERENCE($,'23-17 11 17 17','Plastic Screen Doors',#3004,$,$); +#3009=IFCCLASSIFICATIONREFERENCE($,'23-17 11 17 19','Sliding Plastic Doors',#3004,$,$); +#3010=IFCCLASSIFICATIONREFERENCE($,'23-17 11 17 21','Folding Plastic Doors',#3004,$,$); +#3011=IFCCLASSIFICATIONREFERENCE($,'23-17 11 17 23','Revolving Plastic Doors',#3004,$,$); +#3012=IFCCLASSIFICATIONREFERENCE($,'23-17 11 17 25','Overhead Plastic Doors',#3004,$,$); +#3013=IFCCLASSIFICATIONREFERENCE($,'23-17 11 17 25 11','Roller Shutter Overhead Plastic Doors',#3012,$,$); +#3014=IFCCLASSIFICATIONREFERENCE($,'23-17 11 17 25 13','Sectional Overhead Plastic Doors',#3012,$,$); +#3015=IFCCLASSIFICATIONREFERENCE($,'23-17 11 19','Composite Doors',#2956,$,$); +#3016=IFCCLASSIFICATIONREFERENCE($,'23-17 11 19 11','Fiberglass Composite Doors',#3015,$,$); +#3017=IFCCLASSIFICATIONREFERENCE($,'23-17 11 19 13','Sliding Composite Doors',#3015,$,$); +#3018=IFCCLASSIFICATIONREFERENCE($,'23-17 11 19 15','Folding Composite Doors',#3015,$,$); +#3019=IFCCLASSIFICATIONREFERENCE($,'23-17 11 19 17','Composite Hinged Doors',#3015,$,$); +#3020=IFCCLASSIFICATIONREFERENCE($,'23-17 11 19 19','Revolving Composite Doors',#3015,$,$); +#3021=IFCCLASSIFICATIONREFERENCE($,'23-17 11 19 21','Overhead Composite Doors',#3015,$,$); +#3022=IFCCLASSIFICATIONREFERENCE($,'23-17 11 19 21 11','Roller Shutter Overhead Composite Doors',#3021,$,$); +#3023=IFCCLASSIFICATIONREFERENCE($,'23-17 11 19 21 13','Sectional Overhead Composite Doors',#3021,$,$); +#3024=IFCCLASSIFICATIONREFERENCE($,'23-17 11 21','Glazed Doors',#2956,$,$); +#3025=IFCCLASSIFICATIONREFERENCE($,'23-17 11 21 11','Glazed Hinged Doors',#3024,$,$); +#3026=IFCCLASSIFICATIONREFERENCE($,'23-17 11 23','All Glass Doors',#2956,$,$); +#3027=IFCCLASSIFICATIONREFERENCE($,'23-17 11 23 11','Swinging All Glass Doors',#3026,$,$); +#3028=IFCCLASSIFICATIONREFERENCE($,'23-17 11 23 13','Sliding All Glass Doors',#3026,$,$); +#3029=IFCCLASSIFICATIONREFERENCE($,'23-17 11 23 15','Folding All Glass Doors and Grilles',#3026,$,$); +#3030=IFCCLASSIFICATIONREFERENCE($,'23-17 11 23 15 11','Accordion Folding All Glass Doors',#3029,$,$); +#3031=IFCCLASSIFICATIONREFERENCE($,'23-17 11 23 15 13','Panel Folding All Glass Doors',#3029,$,$); +#3032=IFCCLASSIFICATIONREFERENCE($,'23-17 11 23 15 15','Bifold All Glass Doors',#3029,$,$); +#3033=IFCCLASSIFICATIONREFERENCE($,'23-17 11 23 17','Revolving All Glass Doors',#3026,$,$); +#3034=IFCCLASSIFICATIONREFERENCE($,'23-17 11 23 19','Balanced All Glass Doors',#3026,$,$); +#3035=IFCCLASSIFICATIONREFERENCE($,'23-17 11 25','Passage Grilles',#2956,$,$); +#3036=IFCCLASSIFICATIONREFERENCE($,'23-17 11 25 11','Sliding Passage Grilles',#3035,$,$); +#3037=IFCCLASSIFICATIONREFERENCE($,'23-17 11 25 13','Folding Passage Grilles',#3035,$,$); +#3038=IFCCLASSIFICATIONREFERENCE($,'23-17 11 25 13 11','Accordion Folding Passage Grilles',#3037,$,$); +#3039=IFCCLASSIFICATIONREFERENCE($,'23-17 11 25 15','Rolling Grilles',#3035,$,$); +#3040=IFCCLASSIFICATIONREFERENCE($,'23-17 11 27','Access Doors',#2956,$,$); +#3041=IFCCLASSIFICATIONREFERENCE($,'23-17 11 27 11','Trap Doors',#3040,$,$); +#3042=IFCCLASSIFICATIONREFERENCE($,'23-17 11 27 13','Access Doors',#3040,$,$); +#3043=IFCCLASSIFICATIONREFERENCE($,'23-17 11 27 15','Floor Hatches',#3040,$,$); +#3044=IFCCLASSIFICATIONREFERENCE($,'23-17 11 27 17','Roof Hatches',#3040,$,$); +#3045=IFCCLASSIFICATIONREFERENCE($,'23-17 11 27 19','Security Floor Hatches',#3040,$,$); +#3046=IFCCLASSIFICATIONREFERENCE($,'23-17 11 27 21','Security Roof Hatches',#3040,$,$); +#3047=IFCCLASSIFICATIONREFERENCE($,'23-17 11 27 21 11','Forced Entry and Ballistic Resistant Roof Hatches',#3046,$,$); +#3048=IFCCLASSIFICATIONREFERENCE($,'23-17 11 27 21 13','Ballistic Resistant Roof Hatches',#3046,$,$); +#3049=IFCCLASSIFICATIONREFERENCE($,'23-17 11 27 23','Man Hole Accesses',#3040,$,$); +#3050=IFCCLASSIFICATIONREFERENCE($,'23-17 11 29','Access Panels',#2956,$,$); +#3051=IFCCLASSIFICATIONREFERENCE($,'23-17 11 29 11','Equipment Access Panels',#3050,$,$); +#3052=IFCCLASSIFICATIONREFERENCE($,'23-17 11 31','Fire Doors',#2956,$,$); +#3053=IFCCLASSIFICATIONREFERENCE($,'23-17 11 31 11','Fire Rated Doors',#3052,$,$); +#3054=IFCCLASSIFICATIONREFERENCE($,'23-17 11 31 11 11','Fire Rated Overhead Doors',#3053,$,$); +#3055=IFCCLASSIFICATIONREFERENCE($,'23-17 11 31 11 13','Fire Rated Rolling Doors',#3053,$,$); +#3056=IFCCLASSIFICATIONREFERENCE($,'23-17 11 31 11 15','Fire Rated Sliding Doors',#3053,$,$); +#3057=IFCCLASSIFICATIONREFERENCE($,'23-17 11 31 11 17','Fire Rated Hinged Doors',#3053,$,$); +#3058=IFCCLASSIFICATIONREFERENCE($,'23-17 11 31 11 19','Fire Rated Revolving Doors',#3053,$,$); +#3059=IFCCLASSIFICATIONREFERENCE($,'23-17 11 31 13','Temperature Rate of Rise Fire Doors',#3052,$,$); +#3060=IFCCLASSIFICATIONREFERENCE($,'23-17 11 31 13 11','Temperature Rate of Rise Fire Rated Overhead Doors',#3059,$,$); +#3061=IFCCLASSIFICATIONREFERENCE($,'23-17 11 31 13 13','Temperature Rate of Rise Fire Rated Rolling Doors',#3059,$,$); +#3062=IFCCLASSIFICATIONREFERENCE($,'23-17 11 31 13 15','Temperature Rate of Rise Fire Rated Sliding Doors',#3059,$,$); +#3063=IFCCLASSIFICATIONREFERENCE($,'23-17 11 31 13 17','Temperature Rate of Rise Fire Rated Hinged Doors',#3059,$,$); +#3064=IFCCLASSIFICATIONREFERENCE($,'23-17 11 31 13 19','Temperature Rate of Rise Fire Rated Revolving Doors',#3059,$,$); +#3065=IFCCLASSIFICATIONREFERENCE($,'23-17 11 35','Fire Shutters',#2956,$,$); +#3066=IFCCLASSIFICATIONREFERENCE($,'23-17 11 37','Controlled Environment Doors',#2956,$,$); +#3067=IFCCLASSIFICATIONREFERENCE($,'23-17 11 37 11','Cold Storage Doors',#3066,$,$); +#3068=IFCCLASSIFICATIONREFERENCE($,'23-17 11 37 13','Sound Control Doors',#3066,$,$); +#3069=IFCCLASSIFICATIONREFERENCE($,'23-17 11 37 15','Radiation Protection Doors',#3066,$,$); +#3070=IFCCLASSIFICATIONREFERENCE($,'23-17 11 37 15 11','Electromagnetic Shielding Doors',#3069,$,$); +#3071=IFCCLASSIFICATIONREFERENCE($,'23-17 11 37 15 13','Radio Frequency Protection Doors',#3069,$,$); +#3072=IFCCLASSIFICATIONREFERENCE($,'23-17 11 37 15 15','BO Shielding Doors',#3069,$,$); +#3073=IFCCLASSIFICATIONREFERENCE($,'23-17 11 37 15 17','X Ray Protection Doors',#3069,$,$); +#3074=IFCCLASSIFICATIONREFERENCE($,'23-17 11 37 15 19','Nuclear Radiation Protection Doors',#3069,$,$); +#3075=IFCCLASSIFICATIONREFERENCE($,'23-17 11 37 15 21','High Energy Magnetic Pulse Protection Doors',#3069,$,$); +#3076=IFCCLASSIFICATIONREFERENCE($,'23-17 11 39','Detention Doors',#2956,$,$); +#3077=IFCCLASSIFICATIONREFERENCE($,'23-17 11 41','Hanger Doors',#2956,$,$); +#3078=IFCCLASSIFICATIONREFERENCE($,'23-17 11 43','Lightproof Doors',#2956,$,$); +#3079=IFCCLASSIFICATIONREFERENCE($,'23-17 11 43 11','Revolving Darkroom Door',#3078,$,$); +#3080=IFCCLASSIFICATIONREFERENCE($,'23-17 11 45','Traffic Doors',#2956,$,$); +#3081=IFCCLASSIFICATIONREFERENCE($,'23-17 11 45 11','Flexible Traffic Doors',#3080,$,$); +#3082=IFCCLASSIFICATIONREFERENCE($,'23-17 11 45 13','Flexible Strip Doors',#3080,$,$); +#3083=IFCCLASSIFICATIONREFERENCE($,'23-17 11 45 15','Rigid Panel Traffic Doors',#3080,$,$); +#3084=IFCCLASSIFICATIONREFERENCE($,'23-17 11 45 17','Rapid Opening Doors',#3080,$,$); +#3085=IFCCLASSIFICATIONREFERENCE($,'23-17 11 47','Pressure Resistant Doors',#2956,$,$); +#3086=IFCCLASSIFICATIONREFERENCE($,'23-17 11 47 11','Airtight Doors',#3085,$,$); +#3087=IFCCLASSIFICATIONREFERENCE($,'23-17 11 47 13','Watertight Doors',#3085,$,$); +#3088=IFCCLASSIFICATIONREFERENCE($,'23-17 11 49','Security Rated Door',#2956,$,$); +#3089=IFCCLASSIFICATIONREFERENCE($,'23-17 11 49 11','Blast Resistant Doors',#3088,$,$); +#3090=IFCCLASSIFICATIONREFERENCE($,'23-17 11 49 13','Forced Entry Door',#3088,$,$); +#3091=IFCCLASSIFICATIONREFERENCE($,'23-17 11 49 13 11','Multi Forced Entry Lock Door',#3090,$,$); +#3092=IFCCLASSIFICATIONREFERENCE($,'23-17 11 49 13 13','Single Forced Entry Lock Door',#3090,$,$); +#3093=IFCCLASSIFICATIONREFERENCE($,'23-17 11 49 15','Forced Entry and Ballistic Resistant Door',#3088,$,$); +#3094=IFCCLASSIFICATIONREFERENCE($,'23-17 11 49 17','Ballistic Resistant Door',#3088,$,$); +#3095=IFCCLASSIFICATIONREFERENCE($,'23-17 13 00','Windows',#2955,$,$); +#3096=IFCCLASSIFICATIONREFERENCE($,'23-17 13 11','Window Components',#3095,$,$); +#3097=IFCCLASSIFICATIONREFERENCE($,'23-17 13 11 11','Window Sections',#3096,$,$); +#3098=IFCCLASSIFICATIONREFERENCE($,'23-17 13 11 13','Window Linings and Boards',#3096,$,$); +#3099=IFCCLASSIFICATIONREFERENCE($,'23-17 13 11 15','Window Vents',#3096,$,$); +#3100=IFCCLASSIFICATIONREFERENCE($,'23-17 13 11 17','Window Frames',#3096,$,$); +#3101=IFCCLASSIFICATIONREFERENCE($,'23-17 13 11 19','Transoms',#3096,$,$); +#3102=IFCCLASSIFICATIONREFERENCE($,'23-17 13 11 21','Sidelites',#3096,$,$); +#3103=IFCCLASSIFICATIONREFERENCE($,'23-17 13 11 23','Retractable Screens',#3096,$,$); +#3104=IFCCLASSIFICATIONREFERENCE($,'23-17 13 13','Metal Windows',#3095,$,$); +#3105=IFCCLASSIFICATIONREFERENCE($,'23-17 13 13 11','Metal Fixed Windows',#3104,$,$); +#3106=IFCCLASSIFICATIONREFERENCE($,'23-17 13 13 13','Metal Horizontal Sliding Windows',#3104,$,$); +#3107=IFCCLASSIFICATIONREFERENCE($,'23-17 13 13 15','Metal Single Hung Windows',#3104,$,$); +#3108=IFCCLASSIFICATIONREFERENCE($,'23-17 13 13 17','Metal Double Hung Windows',#3104,$,$); +#3109=IFCCLASSIFICATIONREFERENCE($,'23-17 13 13 19','Metal Triple Hung Windows',#3104,$,$); +#3110=IFCCLASSIFICATIONREFERENCE($,'23-17 13 13 21','Metal Awning Windows',#3104,$,$); +#3111=IFCCLASSIFICATIONREFERENCE($,'23-17 13 13 23','Metal Casement Windows',#3104,$,$); +#3112=IFCCLASSIFICATIONREFERENCE($,'23-17 13 13 25','Metal Hopper Windows',#3104,$,$); +#3113=IFCCLASSIFICATIONREFERENCE($,'23-17 13 13 27','Metal Vertical Pivoted Windows',#3104,$,$); +#3114=IFCCLASSIFICATIONREFERENCE($,'23-17 13 13 29','Metal Jalousie Windows',#3104,$,$); +#3115=IFCCLASSIFICATIONREFERENCE($,'23-17 13 15','Wood Windows',#3095,$,$); +#3116=IFCCLASSIFICATIONREFERENCE($,'23-17 13 15 11','Wood Fixed Windows',#3115,$,$); +#3117=IFCCLASSIFICATIONREFERENCE($,'23-17 13 15 13','Wood Horizontal Sliding Windows',#3115,$,$); +#3118=IFCCLASSIFICATIONREFERENCE($,'23-17 13 15 15','Wood Single Hung Windows',#3115,$,$); +#3119=IFCCLASSIFICATIONREFERENCE($,'23-17 13 15 17','Wood Double Hung Windows',#3115,$,$); +#3120=IFCCLASSIFICATIONREFERENCE($,'23-17 13 15 19','Wood Triple Hung Windows',#3115,$,$); +#3121=IFCCLASSIFICATIONREFERENCE($,'23-17 13 15 21','Wood Awning Windows',#3115,$,$); +#3122=IFCCLASSIFICATIONREFERENCE($,'23-17 13 15 23','Wood Casement Windows',#3115,$,$); +#3123=IFCCLASSIFICATIONREFERENCE($,'23-17 13 15 25','Wood Hopper Windows',#3115,$,$); +#3124=IFCCLASSIFICATIONREFERENCE($,'23-17 13 15 27','Wood Vertical Pivoted Windows',#3115,$,$); +#3125=IFCCLASSIFICATIONREFERENCE($,'23-17 13 15 29','Wood Jalousie Windows',#3115,$,$); +#3126=IFCCLASSIFICATIONREFERENCE($,'23-17 13 17','Plastic Windows',#3095,$,$); +#3127=IFCCLASSIFICATIONREFERENCE($,'23-17 13 17 11','Plastic Fixed Windows',#3126,$,$); +#3128=IFCCLASSIFICATIONREFERENCE($,'23-17 13 17 13','Plastic Horizontal Sliding Windows',#3126,$,$); +#3129=IFCCLASSIFICATIONREFERENCE($,'23-17 13 17 15','Plastic Single Hung Windows',#3126,$,$); +#3130=IFCCLASSIFICATIONREFERENCE($,'23-17 13 17 17','Plastic Double Hung Windows',#3126,$,$); +#3131=IFCCLASSIFICATIONREFERENCE($,'23-17 13 17 19','Plastic Triple Hung Windows',#3126,$,$); +#3132=IFCCLASSIFICATIONREFERENCE($,'23-17 13 17 21','Plastic Awning Windows',#3126,$,$); +#3133=IFCCLASSIFICATIONREFERENCE($,'23-17 13 17 23','Plastic Casement Windows',#3126,$,$); +#3134=IFCCLASSIFICATIONREFERENCE($,'23-17 13 17 25','Plastic Hopper Windows',#3126,$,$); +#3135=IFCCLASSIFICATIONREFERENCE($,'23-17 13 17 27','Plastic Vertical Pivoted Windows',#3126,$,$); +#3136=IFCCLASSIFICATIONREFERENCE($,'23-17 13 17 29','Plastic Jalousie Windows',#3126,$,$); +#3137=IFCCLASSIFICATIONREFERENCE($,'23-17 13 17 31','Plastic Jalousie Awning Windows',#3126,$,$); +#3138=IFCCLASSIFICATIONREFERENCE($,'23-17 13 19','Composite Windows',#3095,$,$); +#3139=IFCCLASSIFICATIONREFERENCE($,'23-17 13 19 11','Composite Fixed Windows',#3138,$,$); +#3140=IFCCLASSIFICATIONREFERENCE($,'23-17 13 19 13','Composite Horizontal Sliding Windows',#3138,$,$); +#3141=IFCCLASSIFICATIONREFERENCE($,'23-17 13 19 15','Composite Single Hung Windows',#3138,$,$); +#3142=IFCCLASSIFICATIONREFERENCE($,'23-17 13 19 17','Composite Double Hung Windows',#3138,$,$); +#3143=IFCCLASSIFICATIONREFERENCE($,'23-17 13 19 19','Composite Triple Hung Windows',#3138,$,$); +#3144=IFCCLASSIFICATIONREFERENCE($,'23-17 13 19 21','Composite Awning Windows',#3138,$,$); +#3145=IFCCLASSIFICATIONREFERENCE($,'23-17 13 19 23','Composite Casement Windows',#3138,$,$); +#3146=IFCCLASSIFICATIONREFERENCE($,'23-17 13 19 25','Composite Hopper Windows',#3138,$,$); +#3147=IFCCLASSIFICATIONREFERENCE($,'23-17 13 19 27','Composite Vertical Pivoted Windows',#3138,$,$); +#3148=IFCCLASSIFICATIONREFERENCE($,'23-17 13 19 29','Composite Jalousie Windows',#3138,$,$); +#3149=IFCCLASSIFICATIONREFERENCE($,'23-17 13 19 31','Composite Jalousie Awning Windows',#3138,$,$); +#3150=IFCCLASSIFICATIONREFERENCE($,'23-17 13 21','Projecting Windows',#3095,$,$); +#3151=IFCCLASSIFICATIONREFERENCE($,'23-17 13 21 11','Bay Windows',#3150,$,$); +#3152=IFCCLASSIFICATIONREFERENCE($,'23-17 13 21 11 11','Angles Bay Windows',#3151,$,$); +#3153=IFCCLASSIFICATIONREFERENCE($,'23-17 13 21 11 13','Box Bay Windows',#3151,$,$); +#3154=IFCCLASSIFICATIONREFERENCE($,'23-17 13 21 13','Bow Windows',#3150,$,$); +#3155=IFCCLASSIFICATIONREFERENCE($,'23-17 13 23','Roof Windows',#3095,$,$); +#3156=IFCCLASSIFICATIONREFERENCE($,'23-17 13 25','Masonry Windows',#3095,$,$); +#3157=IFCCLASSIFICATIONREFERENCE($,'23-17 13 25 11','Glass Masonry Unit Windows',#3156,$,$); +#3158=IFCCLASSIFICATIONREFERENCE($,'23-17 13 27','Special Purpose Windows',#3095,$,$); +#3159=IFCCLASSIFICATIONREFERENCE($,'23-17 13 27 11','Fire Rated Windows',#3158,$,$); +#3160=IFCCLASSIFICATIONREFERENCE($,'23-17 13 27 13','Detention Windows',#3158,$,$); +#3161=IFCCLASSIFICATIONREFERENCE($,'23-17 13 27 15','Pass Windows',#3158,$,$); +#3162=IFCCLASSIFICATIONREFERENCE($,'23-17 13 27 17','Controlled Environment Windows',#3158,$,$); +#3163=IFCCLASSIFICATIONREFERENCE($,'23-17 13 27 17 11','Sound Control Windows',#3162,$,$); +#3164=IFCCLASSIFICATIONREFERENCE($,'23-17 13 27 17 13','Radiation Protection Windows',#3162,$,$); +#3165=IFCCLASSIFICATIONREFERENCE($,'23-17 13 27 17 13 11','Electromagnetic Shielding Windows',#3164,$,$); +#3166=IFCCLASSIFICATIONREFERENCE($,'23-17 13 27 17 13 13','BO Shielding Windows',#3164,$,$); +#3167=IFCCLASSIFICATIONREFERENCE($,'23-17 13 27 17 13 15','Radio Frequency Protection Windows',#3164,$,$); +#3168=IFCCLASSIFICATIONREFERENCE($,'23-17 13 27 17 13 17','X Ray Protection Windows',#3164,$,$); +#3169=IFCCLASSIFICATIONREFERENCE($,'23-17 13 27 17 13 19','Nuclear Radiation Protection Windows',#3164,$,$); +#3170=IFCCLASSIFICATIONREFERENCE($,'23-17 13 27 17 13 21','High Energy Magnetic Pulse Protection Windows',#3164,$,$); +#3171=IFCCLASSIFICATIONREFERENCE($,'23-17 13 29','Security Windows',#3095,$,$); +#3172=IFCCLASSIFICATIONREFERENCE($,'23-17 13 29 11','Ballistic Resistant Windows',#3171,$,$); +#3173=IFCCLASSIFICATIONREFERENCE($,'23-17 13 29 11 11','Teller Forced Entry and Ballistic Resistant Windows',#3172,$,$); +#3174=IFCCLASSIFICATIONREFERENCE($,'23-17 13 29 13','Blast Resistant Windows',#3171,$,$); +#3175=IFCCLASSIFICATIONREFERENCE($,'23-17 13 29 13 11','Blast Resistant Structural Muntin Windows',#3174,$,$); +#3176=IFCCLASSIFICATIONREFERENCE($,'23-17 13 29 13 13','Blast Resistant Window Frames',#3174,$,$); +#3177=IFCCLASSIFICATIONREFERENCE($,'23-17 13 29 15','Impact Resistant Windows',#3171,$,$); +#3178=IFCCLASSIFICATIONREFERENCE($,'23-17 13 29 17','Forced Entry Resistant Windows',#3171,$,$); +#3179=IFCCLASSIFICATIONREFERENCE($,'23-17 13 29 19','Radio Frequency Shielding Windows',#3171,$,$); +#3180=IFCCLASSIFICATIONREFERENCE($,'23-17 13 29 21','Security Window Films',#3171,$,$); +#3181=IFCCLASSIFICATIONREFERENCE($,'23-17 13 29 21 11','Shatter Resistant Security Window Films',#3180,$,$); +#3182=IFCCLASSIFICATIONREFERENCE($,'23-17 13 29 23','Security Window Curtains',#3171,$,$); +#3183=IFCCLASSIFICATIONREFERENCE($,'23-17 13 29 23 11','Security Window Blast Curtains',#3182,$,$); +#3184=IFCCLASSIFICATIONREFERENCE($,'23-17 15 00','Glazing',#2955,$,$); +#3185=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11','Glass Glazing',#3184,$,$); +#3186=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 11','Bent Glass',#3185,$,$); +#3187=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 13','Chemically Strengthened Glass',#3185,$,$); +#3188=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 15','Coated Glass',#3185,$,$); +#3189=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 17','Composite Glass',#3185,$,$); +#3190=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 19','Decorative Glass',#3185,$,$); +#3191=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 21','Fire Rated Glass',#3185,$,$); +#3192=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 23','Float Glass',#3185,$,$); +#3193=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 25','Heat Strengthened Glass',#3185,$,$); +#3194=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 27','Impact Resistant Glass',#3185,$,$); +#3195=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 29','Insulating Glass',#3185,$,$); +#3196=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 31','Laminated Glass',#3185,$,$); +#3197=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 33','Low Emissivity Glass',#3185,$,$); +#3198=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 35','Rolled Glass',#3185,$,$); +#3199=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 37','Spandrel Glass',#3185,$,$); +#3200=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 39','Tempered Glass',#3185,$,$); +#3201=IFCCLASSIFICATIONREFERENCE($,'23-17 15 11 41','Wired Glass',#3185,$,$); +#3202=IFCCLASSIFICATIONREFERENCE($,'23-17 15 13','Plastic Glazing',#3184,$,$); +#3203=IFCCLASSIFICATIONREFERENCE($,'23-17 15 13 11','Ballistics Resistant Plastic Glazing',#3202,$,$); +#3204=IFCCLASSIFICATIONREFERENCE($,'23-17 15 13 13','Decorative Plastic Glazing',#3202,$,$); +#3205=IFCCLASSIFICATIONREFERENCE($,'23-17 15 13 15','Insulating Plastic Glazing',#3202,$,$); +#3206=IFCCLASSIFICATIONREFERENCE($,'23-17 15 13 17','Translucent Plastic Glazing',#3202,$,$); +#3207=IFCCLASSIFICATIONREFERENCE($,'23-17 15 13 19','Transparent Plastic Glazing',#3202,$,$); +#3208=IFCCLASSIFICATIONREFERENCE($,'23-17 15 15','Security Glass',#3184,$,$); +#3209=IFCCLASSIFICATIONREFERENCE($,'23-17 15 15 11','Laminated Security Glass',#3208,$,$); +#3210=IFCCLASSIFICATIONREFERENCE($,'23-17 15 17','Tinted Glass',#3184,$,$); +#3211=IFCCLASSIFICATIONREFERENCE($,'23-17 15 19','Glazing by Special Function',#3184,$,$); +#3212=IFCCLASSIFICATIONREFERENCE($,'23-17 15 19 11','Security Glazing',#3211,$,$); +#3213=IFCCLASSIFICATIONREFERENCE($,'23-17 15 19 13','Ballistics Resistant Glass Glazing',#3211,$,$); +#3214=IFCCLASSIFICATIONREFERENCE($,'23-17 15 19 15','Pressure Resistant Glazing',#3211,$,$); +#3215=IFCCLASSIFICATIONREFERENCE($,'23-17 15 19 17','Hurricane Resistant Glazing',#3211,$,$); +#3216=IFCCLASSIFICATIONREFERENCE($,'23-17 15 19 19','Radiation Resistant Glazing',#3211,$,$); +#3217=IFCCLASSIFICATIONREFERENCE($,'23-17 15 19 21','Switchable Privacy Glass',#3211,$,$); +#3218=IFCCLASSIFICATIONREFERENCE($,'23-17 15 21','Glazing Components',#3184,$,$); +#3219=IFCCLASSIFICATIONREFERENCE($,'23-17 15 21 11','Glazing Frames',#3218,$,$); +#3220=IFCCLASSIFICATIONREFERENCE($,'23-17 15 21 13','Glazing Sections',#3218,$,$); +#3221=IFCCLASSIFICATIONREFERENCE($,'23-17 15 21 15','Mechanical Glazing Fasteners',#3218,$,$); +#3222=IFCCLASSIFICATIONREFERENCE($,'23-17 15 23','Glazing Accessories',#3184,$,$); +#3223=IFCCLASSIFICATIONREFERENCE($,'23-17 15 23 11','Glazing Beads',#3222,$,$); +#3224=IFCCLASSIFICATIONREFERENCE($,'23-17 15 23 13','Condensation Channels',#3222,$,$); +#3225=IFCCLASSIFICATIONREFERENCE($,'23-17 15 23 15','Glazing Sealants and Tapes',#3222,$,$); +#3226=IFCCLASSIFICATIONREFERENCE($,'23-17 15 23 17','Glazing Gaskets',#3222,$,$); +#3227=IFCCLASSIFICATIONREFERENCE($,'23-17 15 23 19','Glazing Leading Material',#3222,$,$); +#3228=IFCCLASSIFICATIONREFERENCE($,'23-17 15 25','Protective Films',#3184,$,$); +#3229=IFCCLASSIFICATIONREFERENCE($,'23-17 15 25 11','Solar Control Films',#3228,$,$); +#3230=IFCCLASSIFICATIONREFERENCE($,'23-17 15 25 13','Safety Films',#3228,$,$); +#3231=IFCCLASSIFICATIONREFERENCE($,'23-17 15 25 15','Security Films',#3228,$,$); +#3232=IFCCLASSIFICATIONREFERENCE($,'23-17 15 25 17','Decorative Films',#3228,$,$); +#3233=IFCCLASSIFICATIONREFERENCE($,'23-17 17 00','Skylights',#2955,$,$); +#3234=IFCCLASSIFICATIONREFERENCE($,'23-17 17 11','Skylight Components',#3233,$,$); +#3235=IFCCLASSIFICATIONREFERENCE($,'23-17 17 11 11','Skylight Hardware',#3234,$,$); +#3236=IFCCLASSIFICATIONREFERENCE($,'23-17 17 13','Unit Skylights',#3233,$,$); +#3237=IFCCLASSIFICATIONREFERENCE($,'23-17 17 13 11','Domed Unit Skylights',#3236,$,$); +#3238=IFCCLASSIFICATIONREFERENCE($,'23-17 17 13 13','Pyramidal Unit Skylights',#3236,$,$); +#3239=IFCCLASSIFICATIONREFERENCE($,'23-17 17 13 15','Vaulted Unit Skylights',#3236,$,$); +#3240=IFCCLASSIFICATIONREFERENCE($,'23-17 17 13 17','Single Slope Unit Skylights',#3236,$,$); +#3241=IFCCLASSIFICATIONREFERENCE($,'23-17 17 13 19','Octagonal Unit Skylights',#3236,$,$); +#3242=IFCCLASSIFICATIONREFERENCE($,'23-17 17 13 21','Tubular Skylights',#3236,$,$); +#3243=IFCCLASSIFICATIONREFERENCE($,'23-17 17 15','Metal Framed Skylights',#3233,$,$); +#3244=IFCCLASSIFICATIONREFERENCE($,'23-17 17 15 11','Domed Metal Framed Skylights',#3243,$,$); +#3245=IFCCLASSIFICATIONREFERENCE($,'23-17 17 15 13','Pyramidal Metal Framed Skylights',#3243,$,$); +#3246=IFCCLASSIFICATIONREFERENCE($,'23-17 17 15 15','Ridge Metal Framed Skylights',#3243,$,$); +#3247=IFCCLASSIFICATIONREFERENCE($,'23-17 17 15 17','Vaulted Metal Framed Skylights',#3243,$,$); +#3248=IFCCLASSIFICATIONREFERENCE($,'23-17 17 15 19','Single Slope Metal Framed Skylights',#3243,$,$); +#3249=IFCCLASSIFICATIONREFERENCE($,'23-17 17 15 21','Octagonal Metal Framed Skylights',#3243,$,$); +#3250=IFCCLASSIFICATIONREFERENCE($,'23-17 19 00','Hardware for Openings',#2955,$,$); +#3251=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11','Hardware for Doors',#3250,$,$); +#3252=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 11','Rotation, Pivoting Door Gear',#3251,$,$); +#3253=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 13','Sliding Door Gear',#3251,$,$); +#3254=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 15','Door Guiding Hardware',#3251,$,$); +#3255=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 17','Door Holding Hardware',#3251,$,$); +#3256=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 17 11','Door Hold Open Hardware',#3255,$,$); +#3257=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 19','Door Closing Hardware',#3251,$,$); +#3258=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 19 11','Door Closers',#3257,$,$); +#3259=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 19 11 11','Manual Floor Door Closers',#3258,$,$); +#3260=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 19 11 13','Manual Surface Door Closers',#3258,$,$); +#3261=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 19 11 15','Manual Concealed Overhead Door Closers',#3258,$,$); +#3262=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 19 11 17','Power Operator Floor Door Closers',#3258,$,$); +#3263=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 19 11 19','Power Operator Surface Door Closers',#3258,$,$); +#3264=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 19 11 21','Power Operator Concealed Overhead Door Closers',#3258,$,$); +#3265=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21','Door Barrier Locks',#3251,$,$); +#3266=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21 11','Door Deadbolt Locks',#3265,$,$); +#3267=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21 13','Door Chains',#3265,$,$); +#3268=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21 15','Door Electric Strike Locks',#3265,$,$); +#3269=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21 17','Door Electromagnetic Locks',#3265,$,$); +#3270=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21 17 11','Door Time Locks',#3269,$,$); +#3271=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21 17 13','Door Time Delay Combination Locks',#3269,$,$); +#3272=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21 19','Door Latches',#3265,$,$); +#3273=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21 21','Door Mortise Locks',#3265,$,$); +#3274=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21 21 11','Door Electric Mortise Locks',#3273,$,$); +#3275=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21 21 13','Door Electronic Mortise Locks',#3273,$,$); +#3276=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21 23','Door Pin Tumbler Locks',#3265,$,$); +#3277=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21 23 11','Door Tubular Pin Tumbler Locks',#3276,$,$); +#3278=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 21 25','Door Flush Bolts',#3265,$,$); +#3279=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 23','Door Cores',#3251,$,$); +#3280=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 25','Door Cylinders',#3251,$,$); +#3281=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 27','Door Key Control Systems',#3251,$,$); +#3282=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 29','Personnel Door Access',#3251,$,$); +#3283=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 29 11','Door Position Switches',#3282,$,$); +#3284=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 29 13','Door Emergency Exit Panic Bars',#3282,$,$); +#3285=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 29 15','Door End of Line Devices',#3282,$,$); +#3286=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 29 17','Door Request to Exit Switches',#3282,$,$); +#3287=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 29 19','Personnel Access Door Keypads',#3282,$,$); +#3288=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 29 19 11','Door Infrared Request to Exit Switches',#3287,$,$); +#3289=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 31','Automatic Door Controls and Operators',#3251,$,$); +#3290=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 31 11','Card Key Door Locking Hardware',#3289,$,$); +#3291=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 31 13','Electrical Door Locking Control',#3289,$,$); +#3292=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 31 15','Electromagnetic Door Holders',#3289,$,$); +#3293=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 31 17','Sensors for Automatic Doors',#3289,$,$); +#3294=IFCCLASSIFICATIONREFERENCE($,'23-17 19 11 33','Door Exiting Hardware',#3251,$,$); +#3295=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13','Hardware for Windows',#3250,$,$); +#3296=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 11','Sliding Window Gear',#3295,$,$); +#3297=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 11 11','Horizontal Sliding Window Gear',#3296,$,$); +#3298=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 11 13','Vertical Sliding Window Gear',#3296,$,$); +#3299=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 13','Horizontal Pivoting Window Gear',#3295,$,$); +#3300=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 15','Window Tilt and Turn Gear',#3295,$,$); +#3301=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 17','Louver Gear',#3295,$,$); +#3302=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 19','Automatic Window Equipment',#3295,$,$); +#3303=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 21','Window Barrier Locks',#3295,$,$); +#3304=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 21 11','Window Deadbolt Locks',#3303,$,$); +#3305=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 21 13','Window Latches',#3303,$,$); +#3306=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 21 15','Window Mortise Locks',#3303,$,$); +#3307=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 21 17','Window Flush Bolts',#3303,$,$); +#3308=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 23','Window Lifts',#3295,$,$); +#3309=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 25','Window Operators',#3295,$,$); +#3310=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 25 11','Manual Surface Window Closers',#3309,$,$); +#3311=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 25 13','Manual Concealed Overhead Window Closers',#3309,$,$); +#3312=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 25 15','Power Operator Surface Window Closers',#3309,$,$); +#3313=IFCCLASSIFICATIONREFERENCE($,'23-17 19 13 25 17','Power Operator Concealed Overhead Window Closers',#3309,$,$); +#3314=IFCCLASSIFICATIONREFERENCE($,'23-17 19 15','Weatherstripping and Seals',#3250,$,$); +#3315=IFCCLASSIFICATIONREFERENCE($,'23-17 19 15 11','Door Weatherstripping and Seals',#3314,$,$); +#3316=IFCCLASSIFICATIONREFERENCE($,'23-17 19 15 11 11','Acoustic Seals',#3315,$,$); +#3317=IFCCLASSIFICATIONREFERENCE($,'23-17 19 15 11 13','Astragals',#3315,$,$); +#3318=IFCCLASSIFICATIONREFERENCE($,'23-17 19 15 11 15','Perimeter Gasketing',#3315,$,$); +#3319=IFCCLASSIFICATIONREFERENCE($,'23-17 19 15 13','Thresholds',#3314,$,$); +#3320=IFCCLASSIFICATIONREFERENCE($,'23-17 19 15 15','Window Weatherstripping and Seals',#3314,$,$); +#3321=IFCCLASSIFICATIONREFERENCE($,'23-17 19 17','Other Openings Hardware',#3250,$,$); +#3322=IFCCLASSIFICATIONREFERENCE($,'23-17 19 17 11','Door Stops',#3321,$,$); +#3323=IFCCLASSIFICATIONREFERENCE($,'23-17 21 00','Protection of Openings',#2955,$,$); +#3324=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11','Exterior Protection of Openings',#3323,$,$); +#3325=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 11','Projecting Screens',#3324,$,$); +#3326=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 11 11','Solid Canopies',#3325,$,$); +#3327=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 11 13','Louvered Canopies',#3325,$,$); +#3328=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 11 15','Solid Vertical Fins',#3325,$,$); +#3329=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 11 17','Louvered Vertical Fins',#3325,$,$); +#3330=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 11 19','Manual Awnings',#3325,$,$); +#3331=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 11 21','Powered Awnings',#3325,$,$); +#3332=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 13','Exterior Shutters',#3324,$,$); +#3333=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 13 11','Folding Exterior Shutters',#3332,$,$); +#3334=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 13 13','Shutter Components',#3332,$,$); +#3335=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 13 13 11','Roller Shutter Gear',#3334,$,$); +#3336=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 13 13 13','Roller Shutter Sections',#3334,$,$); +#3337=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 13 13 15','Roller Shutter Casings',#3334,$,$); +#3338=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 13 15','Sliding Exterior Shutters',#3332,$,$); +#3339=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 13 17','Swinging Exterior Shutters',#3332,$,$); +#3340=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 13 19','Coiling Exterior Shutters',#3332,$,$); +#3341=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 15','Exterior Louvers and Grilles',#3324,$,$); +#3342=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 15 11','Fixed Exterior Louvers and Grilles',#3341,$,$); +#3343=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 15 13','Roller Exterior Louvers and Grilles',#3341,$,$); +#3344=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 15 15','Sliding Exterior Louvers and Grilles',#3341,$,$); +#3345=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 17','Storm Panels',#3324,$,$); +#3346=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 17 11','Demountable Storm Panels',#3345,$,$); +#3347=IFCCLASSIFICATIONREFERENCE($,'23-17 21 11 17 13','Movable Storm Panels',#3345,$,$); +#3348=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13','Interior Window Treatment',#3323,$,$); +#3349=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13 11','Window Blinds',#3348,$,$); +#3350=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13 11 11','Horizontal Window Blinds',#3349,$,$); +#3351=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13 11 13','Vertical Window Blinds',#3349,$,$); +#3352=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13 11 15','Window Blind Components',#3349,$,$); +#3353=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13 11 15 11','Window Slats',#3352,$,$); +#3354=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13 11 15 13','Window Vanes',#3352,$,$); +#3355=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13 11 15 15','Blinds Hardware',#3352,$,$); +#3356=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13 13','Curtains and Drapes',#3348,$,$); +#3357=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13 13 11','Drapery Tracks',#3356,$,$); +#3358=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13 15','Window Interior Shutters',#3348,$,$); +#3359=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13 17','Window Shades',#3348,$,$); +#3360=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13 17 11','Cellular/Pleated Shades',#3359,$,$); +#3361=IFCCLASSIFICATIONREFERENCE($,'23-17 21 13 17 13','Roller Shades',#3359,$,$); +#3362=IFCCLASSIFICATIONREFERENCE($,'23-17 21 15','Fire and Smoke Shutters and Curtains',#3323,$,$); +#3363=IFCCLASSIFICATIONREFERENCE($,'23-17 21 15 11','Fire Shutters',#3362,$,$); +#3364=IFCCLASSIFICATIONREFERENCE($,'23-17 21 15 11 11','Vertical Fire Shutters',#3363,$,$); +#3365=IFCCLASSIFICATIONREFERENCE($,'23-17 21 15 11 13','Horizontal Fire Shutters',#3363,$,$); +#3366=IFCCLASSIFICATIONREFERENCE($,'23-17 21 15 13','Smoke Curtains',#3362,$,$); +#3367=IFCCLASSIFICATIONREFERENCE($,'23-17 21 15 13 11','Water Spray Smoke Curtains',#3366,$,$); +#3368=IFCCLASSIFICATIONREFERENCE($,'23-17 21 15 15','Smoke Shutters',#3362,$,$); +#3369=IFCCLASSIFICATIONREFERENCE($,'23-17 21 17','Insect Screens',#3323,$,$); +#3370=IFCCLASSIFICATIONREFERENCE($,'23-17 21 17 11','Complete Insect Screens',#3369,$,$); +#3371=IFCCLASSIFICATIONREFERENCE($,'23-17 21 17 13','Components',#3369,$,$); +#3372=IFCCLASSIFICATIONREFERENCE($,'23-17 21 17 13 11','Frames for Insect Screens',#3371,$,$); +#3373=IFCCLASSIFICATIONREFERENCE($,'23-17 21 17 13 13','Mesh for Insect Screens',#3371,$,$); +#3374=IFCCLASSIFICATIONREFERENCE($,'23-17 23 00','Circulation and Escape Products',#2955,$,$); +#3375=IFCCLASSIFICATIONREFERENCE($,'23-17 23 11','Ramps',#3374,$,$); +#3376=IFCCLASSIFICATIONREFERENCE($,'23-17 23 13','Walkways',#3374,$,$); +#3377=IFCCLASSIFICATIONREFERENCE($,'23-17 23 15','Ladders',#3374,$,$); +#3378=IFCCLASSIFICATIONREFERENCE($,'23-17 23 15 11','Ladder Component Products',#3377,$,$); +#3379=IFCCLASSIFICATIONREFERENCE($,'23-17 23 15 11 11','Ladder Hardware',#3378,$,$); +#3380=IFCCLASSIFICATIONREFERENCE($,'23-17 23 15 11 13','Rungs',#3378,$,$); +#3381=IFCCLASSIFICATIONREFERENCE($,'23-17 23 15 13','Vertical Ladders',#3377,$,$); +#3382=IFCCLASSIFICATIONREFERENCE($,'23-17 23 15 15','Ship Ladders',#3377,$,$); +#3383=IFCCLASSIFICATIONREFERENCE($,'23-17 23 17','Stairs',#3374,$,$); +#3384=IFCCLASSIFICATIONREFERENCE($,'23-17 23 17 11','Stair Component Products',#3383,$,$); +#3385=IFCCLASSIFICATIONREFERENCE($,'23-17 23 17 11 11','Stair Treads',#3384,$,$); +#3386=IFCCLASSIFICATIONREFERENCE($,'23-17 23 17 11 13','Stair Nosings',#3384,$,$); +#3387=IFCCLASSIFICATIONREFERENCE($,'23-17 23 17 11 15','Stair Tread Coverings',#3384,$,$); +#3388=IFCCLASSIFICATIONREFERENCE($,'23-17 23 17 11 17','Stair Railings',#3384,$,$); +#3389=IFCCLASSIFICATIONREFERENCE($,'23-17 23 17 11 19','Stair Handrails',#3384,$,$); +#3390=IFCCLASSIFICATIONREFERENCE($,'23-17 23 17 11 21','Stair Barrier Gates',#3384,$,$); +#3391=IFCCLASSIFICATIONREFERENCE($,'23-17 23 17 13','Spiral Stairs',#3383,$,$); +#3392=IFCCLASSIFICATIONREFERENCE($,'23-17 23 17 13 11','Metal Spiral Stairs',#3391,$,$); +#3393=IFCCLASSIFICATIONREFERENCE($,'23-17 23 17 13 13','Wood Spiral Stairs',#3391,$,$); +#3394=IFCCLASSIFICATIONREFERENCE($,'23-17 23 17 15','Retractable Stairs',#3383,$,$); +#3395=IFCCLASSIFICATIONREFERENCE($,'23-17 23 19','Fire Escapes',#3374,$,$); +#3396=IFCCLASSIFICATIONREFERENCE($,'23-17 23 19 11','Escape Ladders, Stairs',#3395,$,$); +#3397=IFCCLASSIFICATIONREFERENCE($,'23-17 23 19 11 11','Fire Escapes',#3396,$,$); +#3398=IFCCLASSIFICATIONREFERENCE($,'23-17 23 19 13','Escape Slides',#3395,$,$); +#3399=IFCCLASSIFICATIONREFERENCE($,'23-17 23 21','Evacuation Equipment',#3374,$,$); +#3400=IFCCLASSIFICATIONREFERENCE($,'23-17 23 21 11','Evacuation Slings',#3399,$,$); +#3401=IFCCLASSIFICATIONREFERENCE($,'23-17 23 21 13','Evacuation Chairs',#3399,$,$); +#3402=IFCCLASSIFICATIONREFERENCE($,'23-17 25 00','Circulation Guiding and Protection Products',#2955,$,$); +#3403=IFCCLASSIFICATIONREFERENCE($,'23-17 25 11','Guardrails',#3402,$,$); +#3404=IFCCLASSIFICATIONREFERENCE($,'23-17 25 11 11','Guardrail Component Products',#3403,$,$); +#3405=IFCCLASSIFICATIONREFERENCE($,'23-17 25 11 11 11','Cable Infill Systems',#3404,$,$); +#3406=IFCCLASSIFICATIONREFERENCE($,'23-17 25 11 11 13','Infill Panels',#3404,$,$); +#3407=IFCCLASSIFICATIONREFERENCE($,'23-17 25 11 11 15','Posts, Newel Posts, Pickets',#3404,$,$); +#3408=IFCCLASSIFICATIONREFERENCE($,'23-17 25 11 11 17','Railing',#3404,$,$); +#3409=IFCCLASSIFICATIONREFERENCE($,'23-17 25 13','Handrails',#3402,$,$); +#3410=IFCCLASSIFICATIONREFERENCE($,'23-17 25 13 11','Rope Handrails',#3409,$,$); +#3411=IFCCLASSIFICATIONREFERENCE($,'23-17 25 13 13','Capping',#3409,$,$); +#3412=IFCCLASSIFICATIONREFERENCE($,'23-17 25 13 15','Chain Handrails',#3409,$,$); +#3413=IFCCLASSIFICATIONREFERENCE($,'23-17 25 15','Impact Protection Products',#3402,$,$); +#3414=IFCCLASSIFICATIONREFERENCE($,'23-17 25 15 11','Impact Guard Rails',#3413,$,$); +#3415=IFCCLASSIFICATIONREFERENCE($,'23-17 25 15 11 11','Bumper Guards',#3414,$,$); +#3416=IFCCLASSIFICATIONREFERENCE($,'23-17 25 15 13','Corner Guards',#3413,$,$); +#3417=IFCCLASSIFICATIONREFERENCE($,'23-17 25 15 15','Column Protectors',#3413,$,$); +#3418=IFCCLASSIFICATIONREFERENCE($,'23-17 25 15 17','Door and Wall Protector Products',#3413,$,$); +#3419=IFCCLASSIFICATIONREFERENCE($,'23-17 25 15 17 11','Impact Resistant Wall Protection Products',#3418,$,$); +#3420=IFCCLASSIFICATIONREFERENCE($,'23-19 00 00','Specialty Products',#1606,$,$); +#3421=IFCCLASSIFICATIONREFERENCE($,'23-19 11 00','Information Display Specialties',#3420,$,$); +#3422=IFCCLASSIFICATIONREFERENCE($,'23-19 11 11','Information Signs',#3421,$,$); +#3423=IFCCLASSIFICATIONREFERENCE($,'23-19 11 13','Display Lettering',#3421,$,$); +#3424=IFCCLASSIFICATIONREFERENCE($,'23-19 11 15','Display Numerals',#3421,$,$); +#3425=IFCCLASSIFICATIONREFERENCE($,'23-19 11 17','Notice Boards',#3421,$,$); +#3426=IFCCLASSIFICATIONREFERENCE($,'23-19 11 19','Writing Boards',#3421,$,$); +#3427=IFCCLASSIFICATIONREFERENCE($,'23-19 11 19 11','Interactive Multi Media Whiteboards',#3426,$,$); +#3428=IFCCLASSIFICATIONREFERENCE($,'23-19 11 19 13','Chalk Boards',#3426,$,$); +#3429=IFCCLASSIFICATIONREFERENCE($,'23-19 11 19 15','Dry Erase Boards',#3426,$,$); +#3430=IFCCLASSIFICATIONREFERENCE($,'23-19 11 19 17','Drawing Boards',#3426,$,$); +#3431=IFCCLASSIFICATIONREFERENCE($,'23-19 11 21','Plaques',#3421,$,$); +#3432=IFCCLASSIFICATIONREFERENCE($,'23-19 11 23','Poster Display Units',#3421,$,$); +#3433=IFCCLASSIFICATIONREFERENCE($,'23-19 11 25','Display Screens',#3421,$,$); +#3434=IFCCLASSIFICATIONREFERENCE($,'23-19 11 27','Pictograms',#3421,$,$); +#3435=IFCCLASSIFICATIONREFERENCE($,'23-19 11 29','Directory Boards',#3421,$,$); +#3436=IFCCLASSIFICATIONREFERENCE($,'23-19 11 31','Electronic Copy Boards',#3421,$,$); +#3437=IFCCLASSIFICATIONREFERENCE($,'23-19 11 33','Magnetic Boards',#3421,$,$); +#3438=IFCCLASSIFICATIONREFERENCE($,'23-19 13 00','Lockers',#3420,$,$); +#3439=IFCCLASSIFICATIONREFERENCE($,'23-19 13 11','Metal Lockers',#3438,$,$); +#3440=IFCCLASSIFICATIONREFERENCE($,'23-19 13 13','Plastic Laminate Lockers',#3438,$,$); +#3441=IFCCLASSIFICATIONREFERENCE($,'23-19 13 15','Solid Core Lockers',#3438,$,$); +#3442=IFCCLASSIFICATIONREFERENCE($,'23-19 15 00','Communication Specialties',#3420,$,$); +#3443=IFCCLASSIFICATIONREFERENCE($,'23-19 15 11','Mail Boxes',#3442,$,$); +#3444=IFCCLASSIFICATIONREFERENCE($,'23-19 15 13','Mail Racks',#3442,$,$); +#3445=IFCCLASSIFICATIONREFERENCE($,'23-19 15 15','Pigeonholes',#3442,$,$); +#3446=IFCCLASSIFICATIONREFERENCE($,'23-19 15 17','Mail Trolleys',#3442,$,$); +#3447=IFCCLASSIFICATIONREFERENCE($,'23-19 15 19','Mail Handling Equipment',#3442,$,$); +#3448=IFCCLASSIFICATIONREFERENCE($,'23-19 15 21','Telephone Booths',#3442,$,$); +#3449=IFCCLASSIFICATIONREFERENCE($,'23-19 17 00','Fireplaces',#3420,$,$); +#3450=IFCCLASSIFICATIONREFERENCE($,'23-19 17 11','Electric Fireplace',#3449,$,$); +#3451=IFCCLASSIFICATIONREFERENCE($,'23-19 17 13','Fuel Oil Fireplace',#3449,$,$); +#3452=IFCCLASSIFICATIONREFERENCE($,'23-19 17 15','Gas Fireplace',#3449,$,$); +#3453=IFCCLASSIFICATIONREFERENCE($,'23-19 17 17','Solid Fuel Fireplace',#3449,$,$); +#3454=IFCCLASSIFICATIONREFERENCE($,'23-19 17 19','Fireplace Doors',#3449,$,$); +#3455=IFCCLASSIFICATIONREFERENCE($,'23-19 17 21','Fireplace Water Heaters',#3449,$,$); +#3456=IFCCLASSIFICATIONREFERENCE($,'23-19 19 00','Flue and Chimney Products',#3420,$,$); +#3457=IFCCLASSIFICATIONREFERENCE($,'23-19 19 11','Complete Flue and Chimney Systems',#3456,$,$); +#3458=IFCCLASSIFICATIONREFERENCE($,'23-19 19 11 11','Chimney Gas Vents',#3457,$,$); +#3459=IFCCLASSIFICATIONREFERENCE($,'23-19 19 11 13','Fabricated Stacks',#3457,$,$); +#3460=IFCCLASSIFICATIONREFERENCE($,'23-19 19 11 15','Fabricated Breechings and Accessories',#3457,$,$); +#3461=IFCCLASSIFICATIONREFERENCE($,'23-19 19 11 17','Insulated Sectional Chimneys',#3457,$,$); +#3462=IFCCLASSIFICATIONREFERENCE($,'23-19 19 13','Fireplace Ductwork',#3456,$,$); +#3463=IFCCLASSIFICATIONREFERENCE($,'23-19 19 13 11','Fireplace B Vent Ductwork',#3462,$,$); +#3464=IFCCLASSIFICATIONREFERENCE($,'23-19 19 13 13','Fireplace Direct Vent Ductwork',#3462,$,$); +#3465=IFCCLASSIFICATIONREFERENCE($,'23-19 19 13 15','Fireplace Free Vent Ductwork',#3462,$,$); +#3466=IFCCLASSIFICATIONREFERENCE($,'23-19 19 13 17','Fireplace Tri Wall Vent Ductwork',#3462,$,$); +#3467=IFCCLASSIFICATIONREFERENCE($,'23-19 19 13 19','Fireplace Dampers',#3462,$,$); +#3468=IFCCLASSIFICATIONREFERENCE($,'23-19 19 15','Flue and Chimney Systems Components',#3456,$,$); +#3469=IFCCLASSIFICATIONREFERENCE($,'23-19 19 15 11','Draft Control Devices',#3468,$,$); +#3470=IFCCLASSIFICATIONREFERENCE($,'23-19 19 15 13','Fireplace Lintels',#3468,$,$); +#3471=IFCCLASSIFICATIONREFERENCE($,'23-19 19 15 15','Flue Linings',#3468,$,$); +#3472=IFCCLASSIFICATIONREFERENCE($,'23-19 19 15 17','Flue Caps',#3468,$,$); +#3473=IFCCLASSIFICATIONREFERENCE($,'23-19 19 15 19','Flue Cowls',#3468,$,$); +#3474=IFCCLASSIFICATIONREFERENCE($,'23-19 19 15 21','Chimney Dampers',#3468,$,$); +#3475=IFCCLASSIFICATIONREFERENCE($,'23-19 19 15 23','Fire Shutter Extinguishers',#3468,$,$); +#3476=IFCCLASSIFICATIONREFERENCE($,'23-19 19 15 25','Flue Gas Purifiers',#3468,$,$); +#3477=IFCCLASSIFICATIONREFERENCE($,'23-19 21 00','Hearths',#3420,$,$); +#3478=IFCCLASSIFICATIONREFERENCE($,'23-19 23 00','Kilns',#3420,$,$); +#3479=IFCCLASSIFICATIONREFERENCE($,'23-19 25 00','Pest Control Devices',#3420,$,$); +#3480=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11','Bird Control Devices',#3479,$,$); +#3481=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 11','Roost Inhibitors',#3480,$,$); +#3482=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 11 11','Bird Wire',#3481,$,$); +#3483=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 11 13','Bird Spikes',#3481,$,$); +#3484=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 11 15','Bird Netting',#3481,$,$); +#3485=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 13','Bird Flight Diverters',#3480,$,$); +#3486=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 15','Bird Repellant Devices',#3480,$,$); +#3487=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 15 11','Sonic Repellant Devices',#3486,$,$); +#3488=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 15 13','Ultra Sonic Repellant Devices',#3486,$,$); +#3489=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 15 15','Visual Devices',#3486,$,$); +#3490=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 17','Bird Attractors',#3480,$,$); +#3491=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 19','Bird Control Accessories',#3480,$,$); +#3492=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 19 11','Mounting Clips',#3491,$,$); +#3493=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 19 13','Extension Speakers',#3491,$,$); +#3494=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 19 15','Solar Panels',#3491,$,$); +#3495=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 19 17','Spikes Adhesives',#3491,$,$); +#3496=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 19 19','Foot Pumps',#3491,$,$); +#3497=IFCCLASSIFICATIONREFERENCE($,'23-19 25 11 19 21','Caulking Guns',#3491,$,$); +#3498=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13','Insect Control Devices',#3479,$,$); +#3499=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 11','Electronic Insect Repellers',#3498,$,$); +#3500=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 11 11','Automatic Misting Systems',#3499,$,$); +#3501=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 11 13','Vacuum System s',#3499,$,$); +#3502=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 11 15','Sonic Repellers',#3499,$,$); +#3503=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 11 17','Ultrasonic Repellers',#3499,$,$); +#3504=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 11 19','Electromagnetic Repellers',#3499,$,$); +#3505=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 13','Fly Traps',#3498,$,$); +#3506=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 15','Screens',#3498,$,$); +#3507=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 17','Foam Sealants',#3498,$,$); +#3508=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 19','Fly Boards',#3498,$,$); +#3509=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 21','Insect Control Accessories',#3498,$,$); +#3510=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 21 11','Nozzles',#3509,$,$); +#3511=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 21 13','Tubing',#3509,$,$); +#3512=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 21 15','Risers',#3509,$,$); +#3513=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 21 17','Fittings',#3509,$,$); +#3514=IFCCLASSIFICATIONREFERENCE($,'23-19 25 13 21 19','Remote Controls',#3509,$,$); +#3515=IFCCLASSIFICATIONREFERENCE($,'23-19 25 15','Rodent Control Devices',#3479,$,$); +#3516=IFCCLASSIFICATIONREFERENCE($,'23-19 25 15 11','Traps',#3515,$,$); +#3517=IFCCLASSIFICATIONREFERENCE($,'23-19 25 15 11 11','Snap Traps',#3516,$,$); +#3518=IFCCLASSIFICATIONREFERENCE($,'23-19 25 15 11 13','Glue Traps',#3516,$,$); +#3519=IFCCLASSIFICATIONREFERENCE($,'23-19 25 15 11 15','Sticky Traps',#3516,$,$); +#3520=IFCCLASSIFICATIONREFERENCE($,'23-19 25 15 11 17','Electronic Traps',#3516,$,$); +#3521=IFCCLASSIFICATIONREFERENCE($,'23-19 25 15 13','Ultrasonic Rodent Control Devices',#3515,$,$); +#3522=IFCCLASSIFICATIONREFERENCE($,'23-19 25 15 15','Electronic Rodent Control Devices',#3515,$,$); +#3523=IFCCLASSIFICATIONREFERENCE($,'23-19 25 15 17','Proofing Devices',#3515,$,$); +#3524=IFCCLASSIFICATIONREFERENCE($,'23-19 25 15 19','Tracking Products',#3515,$,$); +#3525=IFCCLASSIFICATIONREFERENCE($,'23-19 25 15 21','Spray Devices',#3515,$,$); +#3526=IFCCLASSIFICATIONREFERENCE($,'23-19 25 15 23','Rodent Control Accessories',#3515,$,$); +#3527=IFCCLASSIFICATIONREFERENCE($,'23-19 27 00','Manufactured Exterior Specialties',#3420,$,$); +#3528=IFCCLASSIFICATIONREFERENCE($,'23-19 27 11','Weathervanes',#3527,$,$); +#3529=IFCCLASSIFICATIONREFERENCE($,'23-19 27 13','Clocks',#3527,$,$); +#3530=IFCCLASSIFICATIONREFERENCE($,'23-19 27 15','Cupolas',#3527,$,$); +#3531=IFCCLASSIFICATIONREFERENCE($,'23-19 27 17','Spires',#3527,$,$); +#3532=IFCCLASSIFICATIONREFERENCE($,'23-19 27 19','Steeples',#3527,$,$); +#3533=IFCCLASSIFICATIONREFERENCE($,'23-19 27 21','Towers',#3527,$,$); +#3534=IFCCLASSIFICATIONREFERENCE($,'23-19 27 23','Industrial Breechings',#3527,$,$); +#3535=IFCCLASSIFICATIONREFERENCE($,'23-19 27 23 11','Industrial Breechings',#3534,$,$); +#3536=IFCCLASSIFICATIONREFERENCE($,'23-19 27 23 13','Fabricated Industrial Breechings',#3534,$,$); +#3537=IFCCLASSIFICATIONREFERENCE($,'23-19 27 23 15','Fabricated Industrial Breechings Accessories',#3534,$,$); +#3538=IFCCLASSIFICATIONREFERENCE($,'23-19 27 25','Industrial Chimneys',#3527,$,$); +#3539=IFCCLASSIFICATIONREFERENCE($,'23-19 27 25 11','Industrial Chimney Shafts',#3538,$,$); +#3540=IFCCLASSIFICATIONREFERENCE($,'23-19 27 25 13','Industrial Chimney Linings',#3538,$,$); +#3541=IFCCLASSIFICATIONREFERENCE($,'23-19 27 25 15','Industrial Chimney Draft Control Devices',#3538,$,$); +#3542=IFCCLASSIFICATIONREFERENCE($,'23-19 27 25 17','Industrial Insulated Sectional Chimneys',#3538,$,$); +#3543=IFCCLASSIFICATIONREFERENCE($,'23-19 27 27','Industrial Stacks',#3527,$,$); +#3544=IFCCLASSIFICATIONREFERENCE($,'23-19 29 00','Complete Buildings',#3420,$,$); +#3545=IFCCLASSIFICATIONREFERENCE($,'23-19 29 11','Pre Engineered Structures',#3544,$,$); +#3546=IFCCLASSIFICATIONREFERENCE($,'23-19 29 11 11','Pre Engineered Structure Component',#3545,$,$); +#3547=IFCCLASSIFICATIONREFERENCE($,'23-19 29 11 11 11','Lift Shaft Components',#3546,$,$); +#3548=IFCCLASSIFICATIONREFERENCE($,'23-19 29 11 13','Framed Pre Engineered Buildings',#3545,$,$); +#3549=IFCCLASSIFICATIONREFERENCE($,'23-19 29 11 15','Panel Structure Pre Engineered Buildings',#3545,$,$); +#3550=IFCCLASSIFICATIONREFERENCE($,'23-19 29 11 17','Cubicle Structure Pre Engineered Buildings',#3545,$,$); +#3551=IFCCLASSIFICATIONREFERENCE($,'23-19 29 11 19','Air Supported Pre Engineered Buildings',#3545,$,$); +#3552=IFCCLASSIFICATIONREFERENCE($,'23-19 29 11 21','Cable Supported Pre Engineered Buildings',#3545,$,$); +#3553=IFCCLASSIFICATIONREFERENCE($,'23-19 29 11 23','Fabric Pre Engineered Building Structures',#3545,$,$); +#3554=IFCCLASSIFICATIONREFERENCE($,'23-19 29 11 25','Prefabricated Dome Structures',#3545,$,$); +#3555=IFCCLASSIFICATIONREFERENCE($,'23-19 29 11 27','Portable Buildings',#3545,$,$); +#3556=IFCCLASSIFICATIONREFERENCE($,'23-19 29 11 29','Mobile Buildings',#3545,$,$); +#3557=IFCCLASSIFICATIONREFERENCE($,'23-19 29 13','Covers and Shelters',#3544,$,$); +#3558=IFCCLASSIFICATIONREFERENCE($,'23-19 29 13 11','General Purpose Shelters',#3557,$,$); +#3559=IFCCLASSIFICATIONREFERENCE($,'23-19 29 13 13','Shelters for Public Transport',#3557,$,$); +#3560=IFCCLASSIFICATIONREFERENCE($,'23-19 29 13 13 11','Bus Stop Shelters',#3559,$,$); +#3561=IFCCLASSIFICATIONREFERENCE($,'23-19 29 13 13 13','Train Platform Shelters',#3559,$,$); +#3562=IFCCLASSIFICATIONREFERENCE($,'23-19 29 13 15','Walkway Coverings',#3557,$,$); +#3563=IFCCLASSIFICATIONREFERENCE($,'23-19 29 13 17','Shelters for Civil Protection',#3557,$,$); +#3564=IFCCLASSIFICATIONREFERENCE($,'23-19 29 13 19','Animal Shelters',#3557,$,$); +#3565=IFCCLASSIFICATIONREFERENCE($,'23-19 29 13 19 11','Kennels',#3564,$,$); +#3566=IFCCLASSIFICATIONREFERENCE($,'23-19 29 13 21','Car Shelters',#3557,$,$); +#3567=IFCCLASSIFICATIONREFERENCE($,'23-19 29 13 23','Shelters for Services',#3557,$,$); +#3568=IFCCLASSIFICATIONREFERENCE($,'23-19 29 13 25','Garden Umbrellas',#3557,$,$); +#3569=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15','Special Purpose Buildings',#3544,$,$); +#3570=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 11','Observatories',#3569,$,$); +#3571=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 13','Control Booths',#3569,$,$); +#3572=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 15','Greenhouses',#3569,$,$); +#3573=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 15 11','Glazed Greenhouse Structures',#3572,$,$); +#3574=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 17','Summerhouses',#3569,$,$); +#3575=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 17 11','Gazebos',#3574,$,$); +#3576=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 17 13','Pavilions',#3574,$,$); +#3577=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 19','Kiosks',#3569,$,$); +#3578=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 21','Public Restrooms',#3569,$,$); +#3579=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 23','Sauna Buildings',#3569,$,$); +#3580=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 25','Funerary Construction Products',#3569,$,$); +#3581=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 25 11','Preassembled Mausoleums',#3580,$,$); +#3582=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 27','General Purpose Booths',#3569,$,$); +#3583=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 27 11','Ticket Booths',#3582,$,$); +#3584=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 27 13','Parking Attendant Booths',#3582,$,$); +#3585=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 27 15','Toll Booths',#3582,$,$); +#3586=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 27 17','Guard Booths',#3582,$,$); +#3587=IFCCLASSIFICATIONREFERENCE($,'23-19 29 15 27 19','Valet Booths',#3582,$,$); +#3588=IFCCLASSIFICATIONREFERENCE($,'23-19 29 17','Building Modules',#3544,$,$); +#3589=IFCCLASSIFICATIONREFERENCE($,'23-19 29 17 11','Prison Cells',#3588,$,$); +#3590=IFCCLASSIFICATIONREFERENCE($,'23-19 29 17 13','Hotel Rooms',#3588,$,$); +#3591=IFCCLASSIFICATIONREFERENCE($,'23-19 29 17 15','Dormitory Rooms',#3588,$,$); +#3592=IFCCLASSIFICATIONREFERENCE($,'23-19 29 19','Integrated Assemblies',#3544,$,$); +#3593=IFCCLASSIFICATIONREFERENCE($,'23-19 29 19 11','Sound, Vibration and Seismic Control Products',#3592,$,$); +#3594=IFCCLASSIFICATIONREFERENCE($,'23-19 29 19 11 11','Floating Floor Construction Products',#3593,$,$); +#3595=IFCCLASSIFICATIONREFERENCE($,'23-19 31 00','Room Units',#3420,$,$); +#3596=IFCCLASSIFICATIONREFERENCE($,'23-19 31 11','General Purpose Room Units',#3595,$,$); +#3597=IFCCLASSIFICATIONREFERENCE($,'23-19 31 11 11','Prefabricated General Purpose Rooms',#3596,$,$); +#3598=IFCCLASSIFICATIONREFERENCE($,'23-19 31 13','Storage Room Units',#3595,$,$); +#3599=IFCCLASSIFICATIONREFERENCE($,'23-19 31 15','Special Purpose Rooms',#3595,$,$); +#3600=IFCCLASSIFICATIONREFERENCE($,'23-19 31 15 11','Athletic Rooms',#3599,$,$); +#3601=IFCCLASSIFICATIONREFERENCE($,'23-19 31 15 11 11','Handball Racquetball Courts',#3600,$,$); +#3602=IFCCLASSIFICATIONREFERENCE($,'23-19 31 15 13','Conservatories',#3599,$,$); +#3603=IFCCLASSIFICATIONREFERENCE($,'23-19 31 15 13 11','Solarium Specialties',#3602,$,$); +#3604=IFCCLASSIFICATIONREFERENCE($,'23-19 31 15 15','Planetariums',#3599,$,$); +#3605=IFCCLASSIFICATIONREFERENCE($,'23-19 31 15 17','Saunas',#3599,$,$); +#3606=IFCCLASSIFICATIONREFERENCE($,'23-19 31 15 19','Steam Baths',#3599,$,$); +#3607=IFCCLASSIFICATIONREFERENCE($,'23-19 31 17','Sanitary Room Units',#3595,$,$); +#3608=IFCCLASSIFICATIONREFERENCE($,'23-19 31 17 11','Bathroom Units',#3607,$,$); +#3609=IFCCLASSIFICATIONREFERENCE($,'23-19 31 17 13','Lavatory Units',#3607,$,$); +#3610=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19','Controlled Environment Rooms',#3595,$,$); +#3611=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 11','Clean Rooms',#3610,$,$); +#3612=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 13','Insulated Rooms',#3610,$,$); +#3613=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 13 11','Cold Storage Rooms',#3612,$,$); +#3614=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 15','Sound Conditioned Rooms',#3610,$,$); +#3615=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 15 11','Practice Booths',#3614,$,$); +#3616=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 17','Hyperbaric Rooms',#3610,$,$); +#3617=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 19','Radiation Protected Rooms',#3610,$,$); +#3618=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 19 11','Electromagnetic Shielded Rooms',#3617,$,$); +#3619=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 19 13','RF Shielded Rooms',#3617,$,$); +#3620=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 19 15','BO Shielded Rooms',#3617,$,$); +#3621=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 19 17','Radio Frequency Protected Rooms',#3617,$,$); +#3622=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 19 19','X Ray Protected Rooms',#3617,$,$); +#3623=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 19 21','Nuclear Radiation Protected Rooms',#3617,$,$); +#3624=IFCCLASSIFICATIONREFERENCE($,'23-19 31 19 19 23','High Energy Magnetic Pulse Protected Rooms',#3617,$,$); +#3625=IFCCLASSIFICATIONREFERENCE($,'23-19 31 21','Plant and Control Room Units',#3595,$,$); +#3626=IFCCLASSIFICATIONREFERENCE($,'23-19 31 21 11','Plant Office Shelters and Booths',#3625,$,$); +#3627=IFCCLASSIFICATIONREFERENCE($,'23-19 31 23','Corridor Units',#3595,$,$); +#3628=IFCCLASSIFICATIONREFERENCE($,'23-21 00 00','Furnishings, Fixtures and Equipment Products',#1606,$,$); +#3629=IFCCLASSIFICATIONREFERENCE($,'23-21 11 00','Commercial Furniture',#3628,$,$); +#3630=IFCCLASSIFICATIONREFERENCE($,'23-21 11 11','Commercial Storage Units',#3629,$,$); +#3631=IFCCLASSIFICATIONREFERENCE($,'23-21 11 11 11','Commercial Storage Shelves',#3630,$,$); +#3632=IFCCLASSIFICATIONREFERENCE($,'23-21 11 11 13','Commercial Storage Supports',#3630,$,$); +#3633=IFCCLASSIFICATIONREFERENCE($,'23-21 11 11 15','Commercial Storage Racking',#3630,$,$); +#3634=IFCCLASSIFICATIONREFERENCE($,'23-21 11 11 17','Commercial Mobile Storage Units',#3630,$,$); +#3635=IFCCLASSIFICATIONREFERENCE($,'23-21 11 11 19','Commercial Filing Cabinets',#3630,$,$); +#3636=IFCCLASSIFICATIONREFERENCE($,'23-21 11 11 21','Architecture Plan Chests',#3630,$,$); +#3637=IFCCLASSIFICATIONREFERENCE($,'23-21 11 11 23','Commercial Desks',#3630,$,$); +#3638=IFCCLASSIFICATIONREFERENCE($,'23-21 11 11 25','Commercial Bookcases',#3630,$,$); +#3639=IFCCLASSIFICATIONREFERENCE($,'23-21 11 11 27','Commercial Key Hangers',#3630,$,$); +#3640=IFCCLASSIFICATIONREFERENCE($,'23-21 13 00','Retail and Office Equipment and Furnishings',#3628,$,$); +#3641=IFCCLASSIFICATIONREFERENCE($,'23-21 13 11','Registration Equipment',#3640,$,$); +#3642=IFCCLASSIFICATIONREFERENCE($,'23-21 13 13','Checkroom Equipment',#3640,$,$); +#3643=IFCCLASSIFICATIONREFERENCE($,'23-21 13 15','Mercantile Equipment and Furnishings',#3640,$,$); +#3644=IFCCLASSIFICATIONREFERENCE($,'23-21 13 17','Barber Shop Equipment',#3640,$,$); +#3645=IFCCLASSIFICATIONREFERENCE($,'23-21 13 19','Beauty Shop Equipment',#3640,$,$); +#3646=IFCCLASSIFICATIONREFERENCE($,'23-21 13 21','Cash Registers',#3640,$,$); +#3647=IFCCLASSIFICATIONREFERENCE($,'23-21 13 23','Checkout Equipment',#3640,$,$); +#3648=IFCCLASSIFICATIONREFERENCE($,'23-21 13 25','Office Equipment',#3640,$,$); +#3649=IFCCLASSIFICATIONREFERENCE($,'23-21 13 25 11','Drafting Equipment',#3648,$,$); +#3650=IFCCLASSIFICATIONREFERENCE($,'23-21 13 25 13','Plotters',#3648,$,$); +#3651=IFCCLASSIFICATIONREFERENCE($,'23-21 13 25 15','Drawing Equipment',#3648,$,$); +#3652=IFCCLASSIFICATIONREFERENCE($,'23-21 13 25 17','Office Accessories',#3648,$,$); +#3653=IFCCLASSIFICATIONREFERENCE($,'23-21 15 00','Wardrobe and Closet Specialties',#3628,$,$); +#3654=IFCCLASSIFICATIONREFERENCE($,'23-21 15 11','Wardrobes',#3653,$,$); +#3655=IFCCLASSIFICATIONREFERENCE($,'23-21 15 13','Chests of Drawers',#3653,$,$); +#3656=IFCCLASSIFICATIONREFERENCE($,'23-21 15 15','Clothing Lockers',#3653,$,$); +#3657=IFCCLASSIFICATIONREFERENCE($,'23-21 15 17','Clothing Racks',#3653,$,$); +#3658=IFCCLASSIFICATIONREFERENCE($,'23-21 15 17 11','Coat Racks',#3657,$,$); +#3659=IFCCLASSIFICATIONREFERENCE($,'23-21 15 17 13','Hat Racks',#3657,$,$); +#3660=IFCCLASSIFICATIONREFERENCE($,'23-21 15 19','Clothing Hangers',#3653,$,$); +#3661=IFCCLASSIFICATIONREFERENCE($,'23-21 15 19 11','Shoe Trees',#3660,$,$); +#3662=IFCCLASSIFICATIONREFERENCE($,'23-21 15 19 13','Coat Hooks',#3660,$,$); +#3663=IFCCLASSIFICATIONREFERENCE($,'23-21 15 19 15','Coat Hangers',#3660,$,$); +#3664=IFCCLASSIFICATIONREFERENCE($,'23-21 15 19 17','Coat Rails',#3660,$,$); +#3665=IFCCLASSIFICATIONREFERENCE($,'23-21 15 21','Cloakroom Units',#3653,$,$); +#3666=IFCCLASSIFICATIONREFERENCE($,'23-21 15 23','Umbrella Storage Stands',#3653,$,$); +#3667=IFCCLASSIFICATIONREFERENCE($,'23-21 15 25','Checkroom Equipment',#3653,$,$); +#3668=IFCCLASSIFICATIONREFERENCE($,'23-21 15 25 11','Manual Checkroom Equipment',#3667,$,$); +#3669=IFCCLASSIFICATIONREFERENCE($,'23-21 15 25 13','Automated Checkroom Equipment',#3667,$,$); +#3670=IFCCLASSIFICATIONREFERENCE($,'23-21 15 27','Clothing Shelving Units',#3653,$,$); +#3671=IFCCLASSIFICATIONREFERENCE($,'23-21 15 27 11','Clothing Shelves',#3670,$,$); +#3672=IFCCLASSIFICATIONREFERENCE($,'23-21 15 27 13','Clothing Shelving and Storage Units',#3670,$,$); +#3673=IFCCLASSIFICATIONREFERENCE($,'23-21 17 00','Interior Refuse Disposal Furniture',#3628,$,$); +#3674=IFCCLASSIFICATIONREFERENCE($,'23-21 17 11','Interior Waste Bins',#3673,$,$); +#3675=IFCCLASSIFICATIONREFERENCE($,'23-21 17 13','Interior Ash Trays',#3673,$,$); +#3676=IFCCLASSIFICATIONREFERENCE($,'23-21 17 15','Interior Refuse Holders',#3673,$,$); +#3677=IFCCLASSIFICATIONREFERENCE($,'23-21 19 00','Casework',#3628,$,$); +#3678=IFCCLASSIFICATIONREFERENCE($,'23-21 19 11','Modular General Casework',#3677,$,$); +#3679=IFCCLASSIFICATIONREFERENCE($,'23-21 19 11 11','Metal Modular General Casework',#3678,$,$); +#3680=IFCCLASSIFICATIONREFERENCE($,'23-21 19 11 13','Wood Modular General Casework',#3678,$,$); +#3681=IFCCLASSIFICATIONREFERENCE($,'23-21 19 11 15','Plastic Modular General Casework',#3678,$,$); +#3682=IFCCLASSIFICATIONREFERENCE($,'23-21 19 13','Custom General Casework',#3677,$,$); +#3683=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15','Specialty Casework',#3677,$,$); +#3684=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 11','Bank Specialty Casework',#3683,$,$); +#3685=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 13','Hospitality Specialty Casework',#3683,$,$); +#3686=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 15','Medical Specialty Casework',#3683,$,$); +#3687=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 15 11','Hospital Specialty Casework',#3686,$,$); +#3688=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 15 13','Nurse Station Specialty Casework',#3686,$,$); +#3689=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 15 15','Exam Room Specialty Casework',#3686,$,$); +#3690=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 15 17','Dental Specialty Casework',#3686,$,$); +#3691=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 15 19','Pharmacy Specialty Casework',#3686,$,$); +#3692=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 17','Display Specialty Casework',#3683,$,$); +#3693=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 19','Religious Specialty Casework',#3683,$,$); +#3694=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 21','Library Specialty Casework',#3683,$,$); +#3695=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 21 11','Library Specialty Casework Study Carrels',#3694,$,$); +#3696=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 21 13','Library Specialty Casework Book Stacks',#3694,$,$); +#3697=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 21 15','Library Specialty Casework Periodical Racks',#3694,$,$); +#3698=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 23','Educational Specialty Casework',#3683,$,$); +#3699=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 23 11','Educational Specialty Casework Study Carrels',#3698,$,$); +#3700=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 25','Laboratory Specialty Casework',#3683,$,$); +#3701=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 25 11','Metal Laboratory Specialty Casework',#3700,$,$); +#3702=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 25 13','Plastic-Laminate-Clad Laboratory Specialty Casework',#3700,$,$); +#3703=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 25 15','Wood Laboratory Specialty Casework',#3700,$,$); +#3704=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 25 17','Solid-Plastic Laboratory Specialty Casework',#3700,$,$); +#3705=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 27','Mortuary Specialty Casework',#3683,$,$); +#3706=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 29','Commercial Kitchen Specialty Casework',#3683,$,$); +#3707=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 31','Darkroom Specialty Casework',#3683,$,$); +#3708=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 33','Residential Specialty Casework',#3683,$,$); +#3709=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 33 11','Residential Kitchen Specialty Casework',#3708,$,$); +#3710=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 33 13','Residential Bathroom Specialty Casework',#3708,$,$); +#3711=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 33 15','Residential Dormitory Specialty Casework',#3708,$,$); +#3712=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 35','Utility Room Specialty Casework',#3683,$,$); +#3713=IFCCLASSIFICATIONREFERENCE($,'23-21 19 15 39','Mailroom Casework',#3683,$,$); +#3714=IFCCLASSIFICATIONREFERENCE($,'23-21 19 17','Casework Components',#3677,$,$); +#3715=IFCCLASSIFICATIONREFERENCE($,'23-21 19 17 11','Casework Component Cabinets',#3714,$,$); +#3716=IFCCLASSIFICATIONREFERENCE($,'23-21 19 17 13','Casework Component Hardware',#3714,$,$); +#3717=IFCCLASSIFICATIONREFERENCE($,'23-21 19 17 15','Casework Component Work Surfaces',#3714,$,$); +#3718=IFCCLASSIFICATIONREFERENCE($,'23-21 21 00','Food Service Equipment and Furnishings',#3628,$,$); +#3719=IFCCLASSIFICATIONREFERENCE($,'23-21 21 11','Commercial Food Services Cabinets',#3718,$,$); +#3720=IFCCLASSIFICATIONREFERENCE($,'23-21 21 11 11','Commercial Hot Cabinets',#3719,$,$); +#3721=IFCCLASSIFICATIONREFERENCE($,'23-21 21 11 13','Commercial Cold Cabinets',#3719,$,$); +#3722=IFCCLASSIFICATIONREFERENCE($,'23-21 21 11 15','Commercial Combination Hot Cold Cabinets',#3719,$,$); +#3723=IFCCLASSIFICATIONREFERENCE($,'23-21 21 11 17','Commercial Pastry Cabinets',#3719,$,$); +#3724=IFCCLASSIFICATIONREFERENCE($,'23-21 21 11 19','Commercial Warming Cabinets',#3719,$,$); +#3725=IFCCLASSIFICATIONREFERENCE($,'23-21 21 11 21','Commercial Snack Cabinets',#3719,$,$); +#3726=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13','Commercial Food Cooking Equipment',#3718,$,$); +#3727=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 11','Commercial Bain Maries',#3726,$,$); +#3728=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 13','Commercial Beverage Equipment',#3726,$,$); +#3729=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 13 11','Commercial Coffee Makers',#3728,$,$); +#3730=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 13 13','Commercial Coffee Warmers',#3728,$,$); +#3731=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 13 15','Commercial Iced Tea Makers',#3728,$,$); +#3732=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 15','Commercial Broilers',#3726,$,$); +#3733=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 15 11','Commercial Steam Broilers',#3732,$,$); +#3734=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 15 13','Commercial Infra Red Broilers',#3732,$,$); +#3735=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 15 15','Commercial Gas Broilers',#3732,$,$); +#3736=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 17','Commercial Food Cookers',#3726,$,$); +#3737=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 17 11','Commercial Food Induction Cookers',#3736,$,$); +#3738=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 17 13','Commercial Pasta Cookers',#3736,$,$); +#3739=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 17 15','Commercial Food Pressure Cookers',#3736,$,$); +#3740=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 17 17','Commercial Rice Cookers',#3736,$,$); +#3741=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 19','Commercial Crepe Machines',#3726,$,$); +#3742=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 21','Commercial Fryers',#3726,$,$); +#3743=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 21 11','Commercial Deep Fryers',#3742,$,$); +#3744=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 21 13','Commercial Pressure Fryers',#3742,$,$); +#3745=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 23','Commercial Frying Pans',#3726,$,$); +#3746=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 23 11','Commercial Tilting Frying Pans',#3745,$,$); +#3747=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 25','Commercial Griddles',#3726,$,$); +#3748=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 27','Commercial Grills',#3726,$,$); +#3749=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 27 11','Commercial Barbecue Grills',#3748,$,$); +#3750=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 27 13','Commercial Char Broiler Grills',#3748,$,$); +#3751=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 27 15','Commercial Hot Dog Grills',#3748,$,$); +#3752=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 29','Commercial Kettles',#3726,$,$); +#3753=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 29 11','Commercial Poacher Kettles',#3752,$,$); +#3754=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 29 13','Commercial Salmon Kettles',#3752,$,$); +#3755=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 31','Commercial Ovens',#3726,$,$); +#3756=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 31 11','Commercial Barbeque Ovens',#3755,$,$); +#3757=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 31 13','Commercial Combination Convection Ovens',#3755,$,$); +#3758=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 31 15','Commercial Convection Ovens',#3755,$,$); +#3759=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 31 17','Commercial Microwave Ovens',#3755,$,$); +#3760=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 31 19','Commercial Pastry Ovens',#3755,$,$); +#3761=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 31 21','Commercial Pizza Ovens',#3755,$,$); +#3762=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 31 23','Commercial Proofer Ovens',#3755,$,$); +#3763=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 31 25','Commercial Smoker Ovens',#3755,$,$); +#3764=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 33','Commercial Popcorn Machines',#3726,$,$); +#3765=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 35','Commercial Ranges',#3726,$,$); +#3766=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 37','Commercial Rotisseries',#3726,$,$); +#3767=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 39','Commercial Food Steamers',#3726,$,$); +#3768=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 39 11','Commercial High Pressure Food Steamer',#3767,$,$); +#3769=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 41','Commercial Skillets',#3726,$,$); +#3770=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 41 11','Commercial Tilt Skillets',#3769,$,$); +#3771=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 43','Commercial Stoves',#3726,$,$); +#3772=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 45','Commercial Toasters',#3726,$,$); +#3773=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 45 11','Commercial Toaster Conveyors',#3772,$,$); +#3774=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 47','Commercial Waffle Irons',#3726,$,$); +#3775=IFCCLASSIFICATIONREFERENCE($,'23-21 21 13 49','Commercial Small Specialized Cooking Equipment',#3726,$,$); +#3776=IFCCLASSIFICATIONREFERENCE($,'23-21 21 15','Commercial Food Services Warming Equipment',#3718,$,$); +#3777=IFCCLASSIFICATIONREFERENCE($,'23-21 21 15 11','Commercial Food Warmers',#3776,$,$); +#3778=IFCCLASSIFICATIONREFERENCE($,'23-21 21 15 13','Commercial Food Warmer Stations',#3776,$,$); +#3779=IFCCLASSIFICATIONREFERENCE($,'23-21 21 15 15','Commercial Hot Plates',#3776,$,$); +#3780=IFCCLASSIFICATIONREFERENCE($,'23-21 21 15 17','Commercial Steam Tables',#3776,$,$); +#3781=IFCCLASSIFICATIONREFERENCE($,'23-21 21 17','Commercial Food Services Cooling Equipment',#3718,$,$); +#3782=IFCCLASSIFICATIONREFERENCE($,'23-21 21 17 11','Commercial Refrigerated Tables',#3781,$,$); +#3783=IFCCLASSIFICATIONREFERENCE($,'23-21 21 19','Commercial Dishwasher Equipment',#3718,$,$); +#3784=IFCCLASSIFICATIONREFERENCE($,'23-21 21 19 11','Commercial Dishwashers',#3783,$,$); +#3785=IFCCLASSIFICATIONREFERENCE($,'23-21 21 19 11 11','Commercial Steam Dishwashers',#3784,$,$); +#3786=IFCCLASSIFICATIONREFERENCE($,'23-21 21 19 11 13','Commercial Dishwasher Conveyors',#3784,$,$); +#3787=IFCCLASSIFICATIONREFERENCE($,'23-21 21 19 11 15','Commercial Dishwasher Tray Conveyors',#3784,$,$); +#3788=IFCCLASSIFICATIONREFERENCE($,'23-21 21 21','Commercial Food Disposal Equipment',#3718,$,$); +#3789=IFCCLASSIFICATIONREFERENCE($,'23-21 21 21 11','Commercial Waste Disposal Units',#3788,$,$); +#3790=IFCCLASSIFICATIONREFERENCE($,'23-21 21 21 13','Commercial Garbage Disposals',#3788,$,$); +#3791=IFCCLASSIFICATIONREFERENCE($,'23-21 21 21 15','Commercial Garbage Pulpers',#3788,$,$); +#3792=IFCCLASSIFICATIONREFERENCE($,'23-21 21 23','Commercial Food Display Equipment',#3718,$,$); +#3793=IFCCLASSIFICATIONREFERENCE($,'23-21 21 23 11','Commercial Food Display Coolers',#3792,$,$); +#3794=IFCCLASSIFICATIONREFERENCE($,'23-21 21 23 11 11','Commercial Freezer Food Display Cases',#3793,$,$); +#3795=IFCCLASSIFICATIONREFERENCE($,'23-21 21 23 11 13','Commercial Heated Food Display Cases',#3793,$,$); +#3796=IFCCLASSIFICATIONREFERENCE($,'23-21 21 23 11 15','Commercial Refrigerated Food Display Cases',#3793,$,$); +#3797=IFCCLASSIFICATIONREFERENCE($,'23-21 21 23 11 17','Commercial Unconditioned Food Display Cases',#3793,$,$); +#3798=IFCCLASSIFICATIONREFERENCE($,'23-21 21 23 13','Commercial Food Guards',#3792,$,$); +#3799=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25','Commercial Food and Beverage Dispensing Equipment',#3718,$,$); +#3800=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 11','Commercial Soda Fountain Equipment',#3799,$,$); +#3801=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 13','Commercial Bottled Water Dispensers',#3799,$,$); +#3802=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 15','Commercial Bowl and Plate Dispensers',#3799,$,$); +#3803=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 17','Commercial Bread Dispensers',#3799,$,$); +#3804=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 19','Commercial Cappuccino or Espresso Dispensers',#3799,$,$); +#3805=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 21','Commercial Carbonated Beverage Dispensers',#3799,$,$); +#3806=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 23','Commercial Coffee Dispensers',#3799,$,$); +#3807=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 25','Commercial Condiment Dispensers',#3799,$,$); +#3808=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 27','Commercial Cream Dispensers',#3799,$,$); +#3809=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 29','Commercial Cup Dispensers',#3799,$,$); +#3810=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 31','Commercial Cup and Saucer Dispensers',#3799,$,$); +#3811=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 33','Commercial Bubbler Dispensers',#3799,$,$); +#3812=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 35','Commercial Drinking Glass Dispensers',#3799,$,$); +#3813=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 37','Commercial Flatware Dispensers',#3799,$,$); +#3814=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 39','Commercial Hot Chocolate Dispensers',#3799,$,$); +#3815=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 41','Commercial Hot Water Dispensers',#3799,$,$); +#3816=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 43','Commercial Ice Cream Dispensers',#3799,$,$); +#3817=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 45','Commercial Milk Dispensers',#3799,$,$); +#3818=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 47','Commercial Milkshake Dispensers',#3799,$,$); +#3819=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 49','Commercial Non Carbonated Beverage Dispensers',#3799,$,$); +#3820=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 49 11','Commercial Refrigerated Non Carbonated Beverage Dispensers',#3819,$,$); +#3821=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 51','Commercial Plate Dispensers',#3799,$,$); +#3822=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 53','Commercial Saucer Dispensers',#3799,$,$); +#3823=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 55','Commercial Slush Dispensers',#3799,$,$); +#3824=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 57','Commercial Soft Serve Ice Cream Dispensers',#3799,$,$); +#3825=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 59','Commercial Syrup Pump Dispensers',#3799,$,$); +#3826=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 61','Commercial Tray Dispensers',#3799,$,$); +#3827=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 63','Commercial Water Filter System',#3799,$,$); +#3828=IFCCLASSIFICATIONREFERENCE($,'23-21 21 25 65','Commercial Filtration Equipment',#3799,$,$); +#3829=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27','Commercial Refrigerators And Freezers',#3718,$,$); +#3830=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 11','Commercial Blast Chillers',#3829,$,$); +#3831=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 13','Commercial Freezers',#3829,$,$); +#3832=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 13 11','Commercial Blast Freezers',#3831,$,$); +#3833=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 13 13','Commercial Chest Freezers',#3831,$,$); +#3834=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 13 15','Commercial Flammable Liquid Freezers',#3831,$,$); +#3835=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 13 17','Commercial Freeze Drying Equipment',#3831,$,$); +#3836=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 13 19','Commercial Plate Freezers',#3831,$,$); +#3837=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 13 21','Commercial Sub Zero Freezers',#3831,$,$); +#3838=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 13 23','Commercial Upright Freezers',#3831,$,$); +#3839=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 13 25','Commercial Upright Reach In Freezers',#3831,$,$); +#3840=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 13 27','Commercial Upright Pass Through Freezers',#3831,$,$); +#3841=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 13 29','Commercial Upright Roll In Freezers',#3831,$,$); +#3842=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 13 31','Commercial Walk In Freezers',#3831,$,$); +#3843=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 15','Commercial Refrigerators',#3829,$,$); +#3844=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 15 11','Commercial Flammable Liquid Refrigerators',#3843,$,$); +#3845=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 15 13','Commercial Liquid Nitrogen Refrigerators',#3843,$,$); +#3846=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 15 15','Commercial Refrigerated Containers',#3843,$,$); +#3847=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 15 17','Commercial Refrigerated Tanks',#3843,$,$); +#3848=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 15 19','Commercial Refrigerated Vessels',#3843,$,$); +#3849=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 15 21','Commercial Upright Refrigerators',#3843,$,$); +#3850=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 15 23','Commercial Upright Reach In Refrigerators',#3843,$,$); +#3851=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 15 25','Commercial Upright Pass Through Refrigerators',#3843,$,$); +#3852=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 15 27','Commercial Upright Roll In Refrigerators',#3843,$,$); +#3853=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 15 29','Commercial Walk In Refrigerators',#3843,$,$); +#3854=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 17','Commercial Refrigerator Freezers',#3829,$,$); +#3855=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 19','Commercial Food Storage Coolers',#3829,$,$); +#3856=IFCCLASSIFICATIONREFERENCE($,'23-21 21 27 19 11','Commercial Walk In Coolers',#3855,$,$); +#3857=IFCCLASSIFICATIONREFERENCE($,'23-21 21 29','Commercial Ice Machines',#3718,$,$); +#3858=IFCCLASSIFICATIONREFERENCE($,'23-21 21 29 11','Commercial Block Ice Makers',#3857,$,$); +#3859=IFCCLASSIFICATIONREFERENCE($,'23-21 21 29 13','Commercial Cube Ice Makers',#3857,$,$); +#3860=IFCCLASSIFICATIONREFERENCE($,'23-21 21 29 15','Commercial Flaker Ice Makers',#3857,$,$); +#3861=IFCCLASSIFICATIONREFERENCE($,'23-21 21 29 17','Commercial Ice Dispensers',#3857,$,$); +#3862=IFCCLASSIFICATIONREFERENCE($,'23-21 21 29 19','Commercial Ice Shaver Dispensers',#3857,$,$); +#3863=IFCCLASSIFICATIONREFERENCE($,'23-21 21 29 21','Commercial Ice Maker Bins',#3857,$,$); +#3864=IFCCLASSIFICATIONREFERENCE($,'23-21 21 31','Commercial Food Preparation Equipment',#3718,$,$); +#3865=IFCCLASSIFICATIONREFERENCE($,'23-21 21 31 11','Commercial Food Mixers',#3864,$,$); +#3866=IFCCLASSIFICATIONREFERENCE($,'23-21 21 31 13','Commercial Food Peelers',#3864,$,$); +#3867=IFCCLASSIFICATIONREFERENCE($,'23-21 21 31 15','Commercial Food Processors',#3864,$,$); +#3868=IFCCLASSIFICATIONREFERENCE($,'23-21 21 31 17','Commercial Food Service Stations',#3864,$,$); +#3869=IFCCLASSIFICATIONREFERENCE($,'23-21 21 31 19','Commercial Food Slicers',#3864,$,$); +#3870=IFCCLASSIFICATIONREFERENCE($,'23-21 21 31 19 11','Commercial Electric Food Slicers',#3869,$,$); +#3871=IFCCLASSIFICATIONREFERENCE($,'23-21 21 31 19 13','Commercial Mechanical Food Slicers',#3869,$,$); +#3872=IFCCLASSIFICATIONREFERENCE($,'23-21 21 31 21','Commercial Food Preparation Tables',#3864,$,$); +#3873=IFCCLASSIFICATIONREFERENCE($,'23-21 21 31 21 11','Commercial Refrigerated Food Preparation Tables',#3872,$,$); +#3874=IFCCLASSIFICATIONREFERENCE($,'23-21 21 31 23','Commercial Drink Making Equipment',#3864,$,$); +#3875=IFCCLASSIFICATIONREFERENCE($,'23-21 21 33','Commercial Food Service Furniture',#3718,$,$); +#3876=IFCCLASSIFICATIONREFERENCE($,'23-21 21 33 11','Commercial Bar Stools',#3875,$,$); +#3877=IFCCLASSIFICATIONREFERENCE($,'23-21 21 33 13','Commercial Restaurant Chairs',#3875,$,$); +#3878=IFCCLASSIFICATIONREFERENCE($,'23-21 21 33 15','Commercial Restaurant Booths',#3875,$,$); +#3879=IFCCLASSIFICATIONREFERENCE($,'23-21 21 33 17','Commercial Restaurant Seating Units',#3875,$,$); +#3880=IFCCLASSIFICATIONREFERENCE($,'23-21 21 33 19','Commercial Restaurant Tables',#3875,$,$); +#3881=IFCCLASSIFICATIONREFERENCE($,'23-21 21 35','Commercial Serving Counters',#3718,$,$); +#3882=IFCCLASSIFICATIONREFERENCE($,'23-21 21 35 11','Commercial Bars',#3881,$,$); +#3883=IFCCLASSIFICATIONREFERENCE($,'23-21 21 35 11 11','Commercial Beverage Bars',#3882,$,$); +#3884=IFCCLASSIFICATIONREFERENCE($,'23-21 21 35 11 13','Commercial Salad Bars',#3882,$,$); +#3885=IFCCLASSIFICATIONREFERENCE($,'23-21 21 35 11 15','Commercial Bar Equipment',#3882,$,$); +#3886=IFCCLASSIFICATIONREFERENCE($,'23-21 21 35 13','Commercial Serving Counters',#3881,$,$); +#3887=IFCCLASSIFICATIONREFERENCE($,'23-21 21 35 13 11','Commercial Condiment Counters',#3886,$,$); +#3888=IFCCLASSIFICATIONREFERENCE($,'23-21 21 35 13 13','Commercial Serving Counters',#3886,$,$); +#3889=IFCCLASSIFICATIONREFERENCE($,'23-21 21 35 15','Commercial Service Line Equipment',#3881,$,$); +#3890=IFCCLASSIFICATIONREFERENCE($,'23-21 21 37','Commercial Food Service Storage Equipment',#3718,$,$); +#3891=IFCCLASSIFICATIONREFERENCE($,'23-21 21 37 11','Commercial Bottle Racks',#3890,$,$); +#3892=IFCCLASSIFICATIONREFERENCE($,'23-21 21 39','Commercial Food Service Delivery Equipment',#3718,$,$); +#3893=IFCCLASSIFICATIONREFERENCE($,'23-21 21 39 11','Commercial Food Delivery Conveyors',#3892,$,$); +#3894=IFCCLASSIFICATIONREFERENCE($,'23-21 21 39 13','Commercial Food Delivery Carts',#3892,$,$); +#3895=IFCCLASSIFICATIONREFERENCE($,'23-21 21 39 15','Commercial Restaurant Turntables',#3892,$,$); +#3896=IFCCLASSIFICATIONREFERENCE($,'23-21 21 41','Commercial Food Service Ventilation Equipment',#3718,$,$); +#3897=IFCCLASSIFICATIONREFERENCE($,'23-21 21 41 11','Commercial Food Hood Equipment',#3896,$,$); +#3898=IFCCLASSIFICATIONREFERENCE($,'23-21 21 41 11 11','Commercial Food Service Hoods',#3897,$,$); +#3899=IFCCLASSIFICATIONREFERENCE($,'23-21 21 41 13','Commercial Food Ventilation Equipment',#3896,$,$); +#3900=IFCCLASSIFICATIONREFERENCE($,'23-21 21 41 13 11','Commercial Food Ventilation Fire Suppression Systems',#3899,$,$); +#3901=IFCCLASSIFICATIONREFERENCE($,'23-21 21 41 13 13','Commercial Catering Ventilation',#3899,$,$); +#3902=IFCCLASSIFICATIONREFERENCE($,'23-21 21 43','Commercial Food Processing Equipment',#3718,$,$); +#3903=IFCCLASSIFICATIONREFERENCE($,'23-21 21 45','Commercial Food Weighing Equipment',#3718,$,$); +#3904=IFCCLASSIFICATIONREFERENCE($,'23-21 21 47','Commercial Food Wrapping Equipment',#3718,$,$); +#3905=IFCCLASSIFICATIONREFERENCE($,'23-21 23 00','Residential Furniture and Equipment',#3628,$,$); +#3906=IFCCLASSIFICATIONREFERENCE($,'23-21 23 11','Complete Residential Dining Room Suites',#3905,$,$); +#3907=IFCCLASSIFICATIONREFERENCE($,'23-21 23 13','Residential Seating',#3905,$,$); +#3908=IFCCLASSIFICATIONREFERENCE($,'23-21 23 13 11','Residential Chairs',#3907,$,$); +#3909=IFCCLASSIFICATIONREFERENCE($,'23-21 23 13 13','Residential Settees',#3907,$,$); +#3910=IFCCLASSIFICATIONREFERENCE($,'23-21 23 13 15','Residential Sofas',#3907,$,$); +#3911=IFCCLASSIFICATIONREFERENCE($,'23-21 23 13 17','Residential Stools',#3907,$,$); +#3912=IFCCLASSIFICATIONREFERENCE($,'23-21 23 13 19','Residential Benches',#3907,$,$); +#3913=IFCCLASSIFICATIONREFERENCE($,'23-21 23 13 21','Residential Chaises Lounges',#3907,$,$); +#3914=IFCCLASSIFICATIONREFERENCE($,'23-21 23 13 23','Residential Sofa Beds',#3907,$,$); +#3915=IFCCLASSIFICATIONREFERENCE($,'23-21 23 13 25','Residential Chair Beds',#3907,$,$); +#3916=IFCCLASSIFICATIONREFERENCE($,'23-21 23 15','Residential Tables',#3905,$,$); +#3917=IFCCLASSIFICATIONREFERENCE($,'23-21 23 15 11','Residential Dining Room Tables',#3916,$,$); +#3918=IFCCLASSIFICATIONREFERENCE($,'23-21 23 15 13','Residential Sideboards',#3916,$,$); +#3919=IFCCLASSIFICATIONREFERENCE($,'23-21 23 15 15','Residential End Tables',#3916,$,$); +#3920=IFCCLASSIFICATIONREFERENCE($,'23-21 23 15 17','Residential Coffee Tables',#3916,$,$); +#3921=IFCCLASSIFICATIONREFERENCE($,'23-21 23 17','Residential Storage Units',#3905,$,$); +#3922=IFCCLASSIFICATIONREFERENCE($,'23-21 23 17 11','Residential Cabinet',#3921,$,$); +#3923=IFCCLASSIFICATIONREFERENCE($,'23-21 23 17 13','Residential China Cabinets',#3921,$,$); +#3924=IFCCLASSIFICATIONREFERENCE($,'23-21 23 17 15','Residential Cupboards',#3921,$,$); +#3925=IFCCLASSIFICATIONREFERENCE($,'23-21 23 17 17','Residential Chests',#3921,$,$); +#3926=IFCCLASSIFICATIONREFERENCE($,'23-21 23 19','Residential Bedroom Furniture',#3905,$,$); +#3927=IFCCLASSIFICATIONREFERENCE($,'23-21 23 19 11','Complete Residential Bedroom Suites',#3926,$,$); +#3928=IFCCLASSIFICATIONREFERENCE($,'23-21 23 19 13','Residential Beds',#3926,$,$); +#3929=IFCCLASSIFICATIONREFERENCE($,'23-21 23 19 13 11','Residential Headboards',#3928,$,$); +#3930=IFCCLASSIFICATIONREFERENCE($,'23-21 23 19 13 13','Residential Footboards',#3928,$,$); +#3931=IFCCLASSIFICATIONREFERENCE($,'23-21 23 19 13 15','Residential Cots',#3928,$,$); +#3932=IFCCLASSIFICATIONREFERENCE($,'23-21 23 19 13 17','Residential Mattresses',#3928,$,$); +#3933=IFCCLASSIFICATIONREFERENCE($,'23-21 23 19 15','Residential Bedside Units',#3926,$,$); +#3934=IFCCLASSIFICATIONREFERENCE($,'23-21 23 19 17','Residential Dressing Tables',#3926,$,$); +#3935=IFCCLASSIFICATIONREFERENCE($,'23-21 23 19 19','Residential Dressers',#3926,$,$); +#3936=IFCCLASSIFICATIONREFERENCE($,'23-21 23 21','Residential Food Cabinets',#3905,$,$); +#3937=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23','Residential Food Cooking Equipment',#3905,$,$); +#3938=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 11','Residential Broilers',#3937,$,$); +#3939=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 11 11','Residential Steam Broilers',#3938,$,$); +#3940=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 11 13','Residential Infra Red Broilers',#3938,$,$); +#3941=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 11 15','Residential Gas Broilers',#3938,$,$); +#3942=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 13','Residential Food Cookers',#3937,$,$); +#3943=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 13 11','Residential Food Induction Cookers',#3942,$,$); +#3944=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 13 13','Residential Pasta Cookers',#3942,$,$); +#3945=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 13 15','Residential Food Pressure Cookers',#3942,$,$); +#3946=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 13 17','Residential Rice Cookers',#3942,$,$); +#3947=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 15','Residential Crepe Machines',#3937,$,$); +#3948=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 17','Residential Fryers',#3937,$,$); +#3949=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 17 11','Residential Deep Fryers',#3948,$,$); +#3950=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 17 13','Residential Pressure Fryers',#3948,$,$); +#3951=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 19','Residential Griddles',#3937,$,$); +#3952=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 21','Residential Grills',#3937,$,$); +#3953=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 21 11','Residential Barbecue Grills',#3952,$,$); +#3954=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 21 13','Residential Char Broiler Grills',#3952,$,$); +#3955=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 21 15','Residential Hot Dog Grills',#3952,$,$); +#3956=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 23','Residential Kettles',#3937,$,$); +#3957=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 23 11','Residential Poacher Kettles',#3956,$,$); +#3958=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 23 13','Residential Salmon Kettles',#3956,$,$); +#3959=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 25','Residential Ovens and Stoves',#3937,$,$); +#3960=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 25 11','Residential Stoves',#3959,$,$); +#3961=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 25 13','Residential Combination Convection Ovens',#3959,$,$); +#3962=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 25 15','Residential Convection Ovens',#3959,$,$); +#3963=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 25 17','Residential Gas Ovens',#3959,$,$); +#3964=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 25 19','Residential Electric Ovens',#3959,$,$); +#3965=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 25 21','Residential Microwave Ovens',#3959,$,$); +#3966=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 27','Residential Rotisseries',#3937,$,$); +#3967=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 29','Residential Food Steamers',#3937,$,$); +#3968=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 29 11','Residential High Pressure Food Steamer',#3967,$,$); +#3969=IFCCLASSIFICATIONREFERENCE($,'23-21 23 23 31','Residential Small Specialized Cooking Equipment',#3937,$,$); +#3970=IFCCLASSIFICATIONREFERENCE($,'23-21 23 25','Residential Dishwashers',#3905,$,$); +#3971=IFCCLASSIFICATIONREFERENCE($,'23-21 23 25 11','Residential Electric Dishwashers',#3970,$,$); +#3972=IFCCLASSIFICATIONREFERENCE($,'23-21 23 25 13','Residential Gas Dishwashers',#3970,$,$); +#3973=IFCCLASSIFICATIONREFERENCE($,'23-21 23 27','Residential Waste Disposal Units',#3905,$,$); +#3974=IFCCLASSIFICATIONREFERENCE($,'23-21 23 27 11','Residential Garbage Disposals',#3973,$,$); +#3975=IFCCLASSIFICATIONREFERENCE($,'23-21 23 27 13','Residential Garbage Compactors',#3973,$,$); +#3976=IFCCLASSIFICATIONREFERENCE($,'23-21 23 27 13 11','Residential Coffee Dispensers',#3975,$,$); +#3977=IFCCLASSIFICATIONREFERENCE($,'23-21 23 29','Residential Food and Beverage Dispensing Equipment',#3905,$,$); +#3978=IFCCLASSIFICATIONREFERENCE($,'23-21 23 29 11','Residential Cappuccino or Espresso Dispensers',#3977,$,$); +#3979=IFCCLASSIFICATIONREFERENCE($,'23-21 23 29 13','Residential Bubbler Dispensers',#3977,$,$); +#3980=IFCCLASSIFICATIONREFERENCE($,'23-21 23 29 15','Residential Hot Water Dispensers',#3977,$,$); +#3981=IFCCLASSIFICATIONREFERENCE($,'23-21 23 31','Residential Water Filter System',#3905,$,$); +#3982=IFCCLASSIFICATIONREFERENCE($,'23-21 23 33','Residential Refrigerators And Freezers',#3905,$,$); +#3983=IFCCLASSIFICATIONREFERENCE($,'23-21 23 33 11','Residential Freezers',#3982,$,$); +#3984=IFCCLASSIFICATIONREFERENCE($,'23-21 23 33 11 11','Residential Chest Freezers',#3983,$,$); +#3985=IFCCLASSIFICATIONREFERENCE($,'23-21 23 33 11 13','Residential Sub Zero Freezers',#3983,$,$); +#3986=IFCCLASSIFICATIONREFERENCE($,'23-21 23 33 11 15','Residential Upright Freezers',#3983,$,$); +#3987=IFCCLASSIFICATIONREFERENCE($,'23-21 23 33 13','Residential Refrigerators',#3982,$,$); +#3988=IFCCLASSIFICATIONREFERENCE($,'23-21 23 33 13 11','Residential Upright Refrigerators',#3987,$,$); +#3989=IFCCLASSIFICATIONREFERENCE($,'23-21 23 33 15','Residential Refrigerator Freezers',#3982,$,$); +#3990=IFCCLASSIFICATIONREFERENCE($,'23-21 23 35','Residential Ice Machines',#3905,$,$); +#3991=IFCCLASSIFICATIONREFERENCE($,'23-21 23 35 11','Residential Cube Ice Makers',#3990,$,$); +#3992=IFCCLASSIFICATIONREFERENCE($,'23-21 23 35 13','Residential Ice Dispensers',#3990,$,$); +#3993=IFCCLASSIFICATIONREFERENCE($,'23-21 23 37','Residential Food Preparation Equipment',#3905,$,$); +#3994=IFCCLASSIFICATIONREFERENCE($,'23-21 23 37 11','Residential Food Mixers',#3993,$,$); +#3995=IFCCLASSIFICATIONREFERENCE($,'23-21 23 37 13','Residential Food Peelers',#3993,$,$); +#3996=IFCCLASSIFICATIONREFERENCE($,'23-21 23 37 15','Residential Food Processors',#3993,$,$); +#3997=IFCCLASSIFICATIONREFERENCE($,'23-21 23 37 17','Residential Food Slicers',#3993,$,$); +#3998=IFCCLASSIFICATIONREFERENCE($,'23-21 23 37 17 11','Residential Electric Food Slicers',#3997,$,$); +#3999=IFCCLASSIFICATIONREFERENCE($,'23-21 23 37 17 13','Residential Mechanical Food Slicers',#3997,$,$); +#4000=IFCCLASSIFICATIONREFERENCE($,'23-21 23 37 19','Residential Food Preparation Tables',#3993,$,$); +#4001=IFCCLASSIFICATIONREFERENCE($,'23-21 23 39','Residential Kitchen and Dining Room Furniture',#3905,$,$); +#4002=IFCCLASSIFICATIONREFERENCE($,'23-21 23 39 11','Residential Bar Stools',#4001,$,$); +#4003=IFCCLASSIFICATIONREFERENCE($,'23-21 23 39 13','Residential Kitchen and Dining Room Chairs',#4001,$,$); +#4004=IFCCLASSIFICATIONREFERENCE($,'23-21 23 39 15','Residential Kitchen and Dining Room Tables',#4001,$,$); +#4005=IFCCLASSIFICATIONREFERENCE($,'23-21 23 39 17','Residential Bars',#4001,$,$); +#4006=IFCCLASSIFICATIONREFERENCE($,'23-21 23 39 17 11','Residential Beverage Bars',#4005,$,$); +#4007=IFCCLASSIFICATIONREFERENCE($,'23-21 23 39 17 13','Residential Bar Equipment',#4005,$,$); +#4008=IFCCLASSIFICATIONREFERENCE($,'23-21 23 41','Residential Food Storage Equipment',#3905,$,$); +#4009=IFCCLASSIFICATIONREFERENCE($,'23-21 23 41 11','Residential Bottle Racks',#4008,$,$); +#4010=IFCCLASSIFICATIONREFERENCE($,'23-21 23 43','Residential Cooking Ventilation Equipment',#3905,$,$); +#4011=IFCCLASSIFICATIONREFERENCE($,'23-21 23 43 11','Residential Range Hoods',#4010,$,$); +#4012=IFCCLASSIFICATIONREFERENCE($,'23-21 23 43 13','Residential Food Ventilation Equipment',#4010,$,$); +#4013=IFCCLASSIFICATIONREFERENCE($,'23-21 23 45','Residential Clothes Airers',#3905,$,$); +#4014=IFCCLASSIFICATIONREFERENCE($,'23-21 23 45 11','Residential Clothes Stands',#4013,$,$); +#4015=IFCCLASSIFICATIONREFERENCE($,'23-21 23 45 13','Residential Clothes Lines',#4013,$,$); +#4016=IFCCLASSIFICATIONREFERENCE($,'23-21 23 47','Residential Combination Laundry Washer Dryers',#3905,$,$); +#4017=IFCCLASSIFICATIONREFERENCE($,'23-21 23 49','Residential Ironing and Pressing Machines',#3905,$,$); +#4018=IFCCLASSIFICATIONREFERENCE($,'23-21 23 51','Residential Laundry Dryers',#3905,$,$); +#4019=IFCCLASSIFICATIONREFERENCE($,'23-21 23 51 11','Residential Electric Laundry Dryers',#4018,$,$); +#4020=IFCCLASSIFICATIONREFERENCE($,'23-21 23 51 13','Residential Gas Laundry Dryers',#4018,$,$); +#4021=IFCCLASSIFICATIONREFERENCE($,'23-21 23 53','Residential Washing Machines',#3905,$,$); +#4022=IFCCLASSIFICATIONREFERENCE($,'23-21 23 53 11','Residential Front Loading Laundry Washers',#4021,$,$); +#4023=IFCCLASSIFICATIONREFERENCE($,'23-21 23 53 13','Residential Side Loading Laundry Washers',#4021,$,$); +#4024=IFCCLASSIFICATIONREFERENCE($,'23-21 23 53 15','Residential Top Loading Laundry Washers',#4021,$,$); +#4025=IFCCLASSIFICATIONREFERENCE($,'23-21 25 00','Educational and Cultural Equipment and Furnishings',#3628,$,$); +#4026=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11','Group Seating',#4025,$,$); +#4027=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 11','Auditorium Seating',#4026,$,$); +#4028=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 11 11','Fixed Audience Seating',#4027,$,$); +#4029=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 11 13','Portable Audience Seating',#4027,$,$); +#4030=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 11 13 11','Folding Audience Chairs',#4029,$,$); +#4031=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 11 13 13','Interlocking Audience Chairs',#4029,$,$); +#4032=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 11 13 15','Stacking Audience Chairs',#4029,$,$); +#4033=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 13','Classroom Furniture',#4026,$,$); +#4034=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 13 11','Seat Assembly',#4033,$,$); +#4035=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 13 13','Table Assembly',#4033,$,$); +#4036=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 13 15','Modular Desks',#4033,$,$); +#4037=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 15','Multiple Use Fixed Seating',#4026,$,$); +#4038=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 17','Platforms',#4026,$,$); +#4039=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 17 11','Portable Stages',#4038,$,$); +#4040=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 17 13','Risers',#4038,$,$); +#4041=IFCCLASSIFICATIONREFERENCE($,'23-21 25 11 19','Language Laboratory Equipment',#4026,$,$); +#4042=IFCCLASSIFICATIONREFERENCE($,'23-21 25 13','Theater and Stage Equipment',#4025,$,$); +#4043=IFCCLASSIFICATIONREFERENCE($,'23-21 25 13 11','Acoustical Shells',#4042,$,$); +#4044=IFCCLASSIFICATIONREFERENCE($,'23-21 25 13 13','Rigging Systems and Controls',#4042,$,$); +#4045=IFCCLASSIFICATIONREFERENCE($,'23-21 25 13 15','Scenery Docks',#4042,$,$); +#4046=IFCCLASSIFICATIONREFERENCE($,'23-21 25 13 17','Suspension Systems',#4042,$,$); +#4047=IFCCLASSIFICATIONREFERENCE($,'23-21 25 13 19','Stage Curtains',#4042,$,$); +#4048=IFCCLASSIFICATIONREFERENCE($,'23-21 25 15','Planetarium Equipment and Furnishings',#4025,$,$); +#4049=IFCCLASSIFICATIONREFERENCE($,'23-21 25 15 11','Planetarium Projectors',#4048,$,$); +#4050=IFCCLASSIFICATIONREFERENCE($,'23-21 25 15 13','Planetarium Seating',#4048,$,$); +#4051=IFCCLASSIFICATIONREFERENCE($,'23-21 25 17','Observatory Equipment and Furnishings',#4025,$,$); +#4052=IFCCLASSIFICATIONREFERENCE($,'23-21 25 17 11','Telescopes',#4051,$,$); +#4053=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19','Ecclesiastical Equipment and Furnishings',#4025,$,$); +#4054=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 11','Religious Seating',#4053,$,$); +#4055=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 11 11','Pews',#4054,$,$); +#4056=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 11 13','Benches',#4054,$,$); +#4057=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 13','Chancel Furnishings',#4053,$,$); +#4058=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 13 11','Lecterns',#4057,$,$); +#4059=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 13 13','Pulpits',#4057,$,$); +#4060=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 13 15','Choir Screens',#4057,$,$); +#4061=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 13 17','Altars',#4057,$,$); +#4062=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 15','Baptisteries',#4053,$,$); +#4063=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 17','Baptismal Fonts',#4053,$,$); +#4064=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 19','Instrumental Equipment',#4053,$,$); +#4065=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 19 11','Organs',#4064,$,$); +#4066=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 19 13','Organ Cases',#4064,$,$); +#4067=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 19 15','Screens',#4064,$,$); +#4068=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 19 17','Bells',#4064,$,$); +#4069=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 19 19','Carillons',#4064,$,$); +#4070=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 21','Synagogue Furniture',#4053,$,$); +#4071=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 23','Mosque Furniture',#4053,$,$); +#4072=IFCCLASSIFICATIONREFERENCE($,'23-21 25 19 25','Temple Furniture',#4053,$,$); +#4073=IFCCLASSIFICATIONREFERENCE($,'23-21 25 21','Library and Archive Equipment and Furnishings',#4025,$,$); +#4074=IFCCLASSIFICATIONREFERENCE($,'23-21 25 21 11','Library Stack Systems',#4073,$,$); +#4075=IFCCLASSIFICATIONREFERENCE($,'23-21 25 21 11 11','Library Shelving',#4074,$,$); +#4076=IFCCLASSIFICATIONREFERENCE($,'23-21 25 21 13','Book Depositories',#4073,$,$); +#4077=IFCCLASSIFICATIONREFERENCE($,'23-21 25 21 15','Book Theft Protection Equipment',#4073,$,$); +#4078=IFCCLASSIFICATIONREFERENCE($,'23-21 25 21 17','Library Furniture',#4073,$,$); +#4079=IFCCLASSIFICATIONREFERENCE($,'23-21 25 21 17 11','Library Filing Furniture',#4078,$,$); +#4080=IFCCLASSIFICATIONREFERENCE($,'23-21 25 21 17 13','Library Display Furniture',#4078,$,$); +#4081=IFCCLASSIFICATIONREFERENCE($,'23-21 25 21 17 15','Study Carrels',#4078,$,$); +#4082=IFCCLASSIFICATIONREFERENCE($,'23-21 25 23','Exhibition Equipment and Furnishings',#4025,$,$); +#4083=IFCCLASSIFICATIONREFERENCE($,'23-21 25 23 11','Display Furniture',#4082,$,$); +#4084=IFCCLASSIFICATIONREFERENCE($,'23-21 25 23 11 11','Display Cabinets',#4083,$,$); +#4085=IFCCLASSIFICATIONREFERENCE($,'23-21 25 23 11 13','Display Racks',#4083,$,$); +#4086=IFCCLASSIFICATIONREFERENCE($,'23-21 25 23 11 15','Display Carousels',#4083,$,$); +#4087=IFCCLASSIFICATIONREFERENCE($,'23-21 25 23 13','Gallery Hanging Systems',#4082,$,$); +#4088=IFCCLASSIFICATIONREFERENCE($,'23-21 25 23 15','Pedestals',#4082,$,$); +#4089=IFCCLASSIFICATIONREFERENCE($,'23-21 25 23 17','Retail Cabinets',#4082,$,$); +#4090=IFCCLASSIFICATIONREFERENCE($,'23-21 25 23 19','Exhibition Stands',#4082,$,$); +#4091=IFCCLASSIFICATIONREFERENCE($,'23-21 25 23 21','Shell Schemes',#4082,$,$); +#4092=IFCCLASSIFICATIONREFERENCE($,'23-21 25 23 23','Exhibit Equipment',#4082,$,$); +#4093=IFCCLASSIFICATIONREFERENCE($,'23-21 27 00','Child Furnishings',#3628,$,$); +#4094=IFCCLASSIFICATIONREFERENCE($,'23-21 27 11','Child Beds',#4093,$,$); +#4095=IFCCLASSIFICATIONREFERENCE($,'23-21 27 11 11','Infant Cradles',#4094,$,$); +#4096=IFCCLASSIFICATIONREFERENCE($,'23-21 27 11 13','Bassinets',#4094,$,$); +#4097=IFCCLASSIFICATIONREFERENCE($,'23-21 27 11 15','Infant Beds',#4094,$,$); +#4098=IFCCLASSIFICATIONREFERENCE($,'23-21 27 11 17','Toddler Beds',#4094,$,$); +#4099=IFCCLASSIFICATIONREFERENCE($,'23-21 27 11 19','Children Beds',#4094,$,$); +#4100=IFCCLASSIFICATIONREFERENCE($,'23-21 27 13','Child Cots',#4093,$,$); +#4101=IFCCLASSIFICATIONREFERENCE($,'23-21 27 13 11','Toddler Cots',#4100,$,$); +#4102=IFCCLASSIFICATIONREFERENCE($,'23-21 27 13 13','Children Cots',#4100,$,$); +#4103=IFCCLASSIFICATIONREFERENCE($,'23-21 27 13 15','Cot Carrier',#4100,$,$); +#4104=IFCCLASSIFICATIONREFERENCE($,'23-21 27 15','Child Playpens',#4093,$,$); +#4105=IFCCLASSIFICATIONREFERENCE($,'23-21 27 17','Child Benches',#4093,$,$); +#4106=IFCCLASSIFICATIONREFERENCE($,'23-21 27 17 11','Toddler Benches',#4105,$,$); +#4107=IFCCLASSIFICATIONREFERENCE($,'23-21 27 17 13','Children Benches',#4105,$,$); +#4108=IFCCLASSIFICATIONREFERENCE($,'23-21 27 19','Child Bathtub',#4093,$,$); +#4109=IFCCLASSIFICATIONREFERENCE($,'23-21 27 19 11','Infant Bathtubs',#4108,$,$); +#4110=IFCCLASSIFICATIONREFERENCE($,'23-21 27 19 13','Toddler Bathtubs',#4108,$,$); +#4111=IFCCLASSIFICATIONREFERENCE($,'23-21 27 19 15','Children Bathtubs',#4108,$,$); +#4112=IFCCLASSIFICATIONREFERENCE($,'23-21 27 21','Child Chairs',#4093,$,$); +#4113=IFCCLASSIFICATIONREFERENCE($,'23-21 27 21 11','Child High Chairs',#4112,$,$); +#4114=IFCCLASSIFICATIONREFERENCE($,'23-21 27 21 13','Child Stools',#4112,$,$); +#4115=IFCCLASSIFICATIONREFERENCE($,'23-21 27 23','Child Play Panels',#4093,$,$); +#4116=IFCCLASSIFICATIONREFERENCE($,'23-21 27 25','Child Indoor Swings',#4093,$,$); +#4117=IFCCLASSIFICATIONREFERENCE($,'23-21 27 25 11','Infant Swings',#4116,$,$); +#4118=IFCCLASSIFICATIONREFERENCE($,'23-21 27 25 13','Toddler Swings',#4116,$,$); +#4119=IFCCLASSIFICATIONREFERENCE($,'23-21 27 27','Child Sofas',#4093,$,$); +#4120=IFCCLASSIFICATIONREFERENCE($,'23-21 27 29','Child Strollers',#4093,$,$); +#4121=IFCCLASSIFICATIONREFERENCE($,'23-21 27 29 11','Child Carriage Strollers',#4120,$,$); +#4122=IFCCLASSIFICATIONREFERENCE($,'23-21 27 29 13','Child Multiple Carriage Strollers',#4120,$,$); +#4123=IFCCLASSIFICATIONREFERENCE($,'23-21 27 29 15','Child Perambulators',#4120,$,$); +#4124=IFCCLASSIFICATIONREFERENCE($,'23-21 27 29 17','Child Buggies',#4120,$,$); +#4125=IFCCLASSIFICATIONREFERENCE($,'23-21 27 31','Child Tables',#4093,$,$); +#4126=IFCCLASSIFICATIONREFERENCE($,'23-21 27 31 11','Diaper Changing Tables',#4125,$,$); +#4127=IFCCLASSIFICATIONREFERENCE($,'23-21 27 33','Child Storage Units',#4093,$,$); +#4128=IFCCLASSIFICATIONREFERENCE($,'23-21 27 33 11','Child File Cabinets',#4127,$,$); +#4129=IFCCLASSIFICATIONREFERENCE($,'23-21 27 33 13','Child Kiosks',#4127,$,$); +#4130=IFCCLASSIFICATIONREFERENCE($,'23-21 27 33 15','Child Shelves',#4127,$,$); +#4131=IFCCLASSIFICATIONREFERENCE($,'23-21 27 33 17','Child Book Display Units',#4127,$,$); +#4132=IFCCLASSIFICATIONREFERENCE($,'23-21 27 33 19','Child Card Catalog Units',#4127,$,$); +#4133=IFCCLASSIFICATIONREFERENCE($,'23-21 27 33 21','Child Cubbies',#4127,$,$); +#4134=IFCCLASSIFICATIONREFERENCE($,'23-21 27 35','Child Dressers',#4093,$,$); +#4135=IFCCLASSIFICATIONREFERENCE($,'23-21 29 00','Athletic and Recreational Equipment',#3628,$,$); +#4136=IFCCLASSIFICATIONREFERENCE($,'23-21 29 11','Athletic or Recreation Screening',#4135,$,$); +#4137=IFCCLASSIFICATIONREFERENCE($,'23-21 29 11 11','Tennis Court Windbreakers',#4136,$,$); +#4138=IFCCLASSIFICATIONREFERENCE($,'23-21 29 13','Athletic Surfacing',#4135,$,$); +#4139=IFCCLASSIFICATIONREFERENCE($,'23-21 29 13 11','Baseball Field Surfacing',#4138,$,$); +#4140=IFCCLASSIFICATIONREFERENCE($,'23-21 29 13 13','Multi Purpose Court Surfacing',#4138,$,$); +#4141=IFCCLASSIFICATIONREFERENCE($,'23-21 29 13 15','Resilient Matting',#4138,$,$); +#4142=IFCCLASSIFICATIONREFERENCE($,'23-21 29 13 17','Synthetic Grass Surfacing',#4138,$,$); +#4143=IFCCLASSIFICATIONREFERENCE($,'23-21 29 13 19','Synthetic Running Track Surfacing',#4138,$,$); +#4144=IFCCLASSIFICATIONREFERENCE($,'23-21 29 13 21','Tennis Court Surfacing',#4138,$,$); +#4145=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15','Athletic Equipment',#4135,$,$); +#4146=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 11','Bowling Alley Equipment',#4145,$,$); +#4147=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 13','Goalposts',#4145,$,$); +#4148=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 15','Nets',#4145,$,$); +#4149=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 17','Backstops',#4145,$,$); +#4150=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 19','Scoreboards',#4145,$,$); +#4151=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 21','Time Clocks',#4145,$,$); +#4152=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 23','Floor Sockets',#4145,$,$); +#4153=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 25','Climbing Equipment',#4145,$,$); +#4154=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 25 11','Climbing Walls',#4153,$,$); +#4155=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 25 13','Climbing Ropes',#4153,$,$); +#4156=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 27','Gymnasium Dividers',#4145,$,$); +#4157=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 29','Wall Mats',#4145,$,$); +#4158=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 31','Floor Mats',#4145,$,$); +#4159=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 33','Referee Platforms',#4145,$,$); +#4160=IFCCLASSIFICATIONREFERENCE($,'23-21 29 15 35','Athletic Equipment Storage Racks',#4145,$,$); +#4161=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17','Playground Equipment',#4135,$,$); +#4162=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 11','Climbing Apparatus',#4161,$,$); +#4163=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 13','Climbing Walls',#4161,$,$); +#4164=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 13 11','Harness Equipment',#4163,$,$); +#4165=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 15','Merry Go Rounds',#4161,$,$); +#4166=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 17','Playhouse Gardens',#4161,$,$); +#4167=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 19','Rope Climbing Equipment',#4161,$,$); +#4168=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 21','Sand Tables',#4161,$,$); +#4169=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 23','Water Tables',#4161,$,$); +#4170=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 25','Sandboxes',#4161,$,$); +#4171=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 27','See Saws',#4161,$,$); +#4172=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 27 11','Spring, Rocking Equipment',#4171,$,$); +#4173=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 29','Slides',#4161,$,$); +#4174=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 31','Swings',#4161,$,$); +#4175=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 31 11','Harness Swings',#4174,$,$); +#4176=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 31 13','Rope Swings',#4174,$,$); +#4177=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 31 15','Tire Swings',#4174,$,$); +#4178=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 31 17','Seat Swings',#4174,$,$); +#4179=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 33','Playground Tunnel',#4161,$,$); +#4180=IFCCLASSIFICATIONREFERENCE($,'23-21 29 17 35','Play Structures',#4161,$,$); +#4181=IFCCLASSIFICATIONREFERENCE($,'23-21 29 19','Recreational Equipment',#4135,$,$); +#4182=IFCCLASSIFICATIONREFERENCE($,'23-21 29 19 11','Ping Pong Equipment',#4181,$,$); +#4183=IFCCLASSIFICATIONREFERENCE($,'23-21 29 19 13','Arcade Machines',#4181,$,$); +#4184=IFCCLASSIFICATIONREFERENCE($,'23-21 29 19 15','Billiards Equipment',#4181,$,$); +#4185=IFCCLASSIFICATIONREFERENCE($,'23-21 29 19 17','Sauna Equipment',#4181,$,$); +#4186=IFCCLASSIFICATIONREFERENCE($,'23-21 29 19 19','Steam Room Equipment',#4181,$,$); +#4187=IFCCLASSIFICATIONREFERENCE($,'23-21 29 19 21','Shooting Range Equipment',#4181,$,$); +#4188=IFCCLASSIFICATIONREFERENCE($,'23-21 29 19 23','Swimming Pool Equipment',#4181,$,$); +#4189=IFCCLASSIFICATIONREFERENCE($,'23-21 29 19 23 11','Diving Boards',#4188,$,$); +#4190=IFCCLASSIFICATIONREFERENCE($,'23-21 29 19 23 13','Starting Blocks',#4188,$,$); +#4191=IFCCLASSIFICATIONREFERENCE($,'23-21 29 19 23 15','Ladders',#4188,$,$); +#4192=IFCCLASSIFICATIONREFERENCE($,'23-21 29 21','Pools',#4135,$,$); +#4193=IFCCLASSIFICATIONREFERENCE($,'23-21 29 21 11','Leisure Whirlpools',#4192,$,$); +#4194=IFCCLASSIFICATIONREFERENCE($,'23-21 29 21 13','Hot Tubs',#4192,$,$); +#4195=IFCCLASSIFICATIONREFERENCE($,'23-21 29 21 15','Swimming Pools',#4192,$,$); +#4196=IFCCLASSIFICATIONREFERENCE($,'23-21 29 21 17','Lap Pools',#4192,$,$); +#4197=IFCCLASSIFICATIONREFERENCE($,'23-21 29 23','Spectator Stands',#4135,$,$); +#4198=IFCCLASSIFICATIONREFERENCE($,'23-21 29 23 11','Fixed Stadium Seating',#4197,$,$); +#4199=IFCCLASSIFICATIONREFERENCE($,'23-21 29 23 13','Telescoping Stands',#4197,$,$); +#4200=IFCCLASSIFICATIONREFERENCE($,'23-21 29 23 15','Bleachers',#4197,$,$); +#4201=IFCCLASSIFICATIONREFERENCE($,'23-21 29 23 15 11','Telescoping Bleachers',#4200,$,$); +#4202=IFCCLASSIFICATIONREFERENCE($,'23-21 29 23 17','Telescoping Chair Platforms',#4197,$,$); +#4203=IFCCLASSIFICATIONREFERENCE($,'23-21 31 00','Fitness and Exercise Equipment',#3628,$,$); +#4204=IFCCLASSIFICATIONREFERENCE($,'23-21 31 11','Exercise Apparatus',#4203,$,$); +#4205=IFCCLASSIFICATIONREFERENCE($,'23-21 31 11 11','Weight Training Exercise Apparatus',#4204,$,$); +#4206=IFCCLASSIFICATIONREFERENCE($,'23-21 31 11 11 11','Multi Station Weight Training Exercise Apparatus',#4205,$,$); +#4207=IFCCLASSIFICATIONREFERENCE($,'23-21 31 13','Exercise Bars',#4203,$,$); +#4208=IFCCLASSIFICATIONREFERENCE($,'23-21 31 13 11','Chinning Bars',#4207,$,$); +#4209=IFCCLASSIFICATIONREFERENCE($,'23-21 31 13 13','Weightlifting Bars',#4207,$,$); +#4210=IFCCLASSIFICATIONREFERENCE($,'23-21 31 15','Exercise Benches',#4203,$,$); +#4211=IFCCLASSIFICATIONREFERENCE($,'23-21 31 15 11','Weightlifting Benches',#4210,$,$); +#4212=IFCCLASSIFICATIONREFERENCE($,'23-21 31 15 11 11','Adjustable Utility Weightlifting Benches',#4211,$,$); +#4213=IFCCLASSIFICATIONREFERENCE($,'23-21 31 15 11 13','Decline Weightlifting Benches',#4211,$,$); +#4214=IFCCLASSIFICATIONREFERENCE($,'23-21 31 15 11 15','Incline Weightlifting Benches',#4211,$,$); +#4215=IFCCLASSIFICATIONREFERENCE($,'23-21 31 15 11 17','Supine Weightlifting Benches',#4211,$,$); +#4216=IFCCLASSIFICATIONREFERENCE($,'23-21 31 17','Exercise Boards',#4203,$,$); +#4217=IFCCLASSIFICATIONREFERENCE($,'23-21 31 17 11','Abdominal Exercise Boards',#4216,$,$); +#4218=IFCCLASSIFICATIONREFERENCE($,'23-21 31 17 11 11','Raised and Bent Leg Abdominal Exercise Boards',#4217,$,$); +#4219=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19','Exercise Machines',#4203,$,$); +#4220=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 11','Abdominal Exercise Machines',#4219,$,$); +#4221=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 13','Back Extension Exercise Machines',#4219,$,$); +#4222=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 15','Biceps Exercise Machines',#4219,$,$); +#4223=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 17','Chest Exercise Machines',#4219,$,$); +#4224=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 19','Closed Chain Exercise Machines',#4219,$,$); +#4225=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 21','Hip Exercise Machines',#4219,$,$); +#4226=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 21 11','Hip Abduction Exercise Machines',#4225,$,$); +#4227=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 21 13','Hip Adduction Exercise Machines',#4225,$,$); +#4228=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 23','Leg Exercise Machines',#4219,$,$); +#4229=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 23 11','Leg Curl Exercise Machines',#4228,$,$); +#4230=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 23 13','Leg Extension Exercise Machines',#4228,$,$); +#4231=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 23 15','Leg Press Exercise Machines',#4228,$,$); +#4232=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 23 17','Leg Press Squat Exercise Machines',#4228,$,$); +#4233=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 23 19','Leg Squat Exercise Machines',#4228,$,$); +#4234=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 25','Neck Exercise Machines',#4219,$,$); +#4235=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 27','Pullover Exercise Machines',#4219,$,$); +#4236=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 29','Rotary Shoulder Exercise Machines',#4219,$,$); +#4237=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 31','Rowing Exercise Machines',#4219,$,$); +#4238=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 33','Shoulder Exercise Machines',#4219,$,$); +#4239=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 35','Treadmills',#4219,$,$); +#4240=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 37','Triceps Exercise Machines',#4219,$,$); +#4241=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 39','Continuous Passive Motion CPM Exercisers',#4219,$,$); +#4242=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 41','Ladder Exercisers',#4219,$,$); +#4243=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 43','Exercise Platforms',#4219,$,$); +#4244=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 45','Ramp Curb Exercisers',#4219,$,$); +#4245=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 47','Staircase Exercisers',#4219,$,$); +#4246=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 49','Upper and Lower Extremities Exercisers',#4219,$,$); +#4247=IFCCLASSIFICATIONREFERENCE($,'23-21 31 19 51','Upper Body Exercisers',#4219,$,$); +#4248=IFCCLASSIFICATIONREFERENCE($,'23-21 31 21','Exercise Floor Mats',#4203,$,$); +#4249=IFCCLASSIFICATIONREFERENCE($,'23-21 31 23','Exercise Pulleys',#4203,$,$); +#4250=IFCCLASSIFICATIONREFERENCE($,'23-21 31 23 11','Triplex Exercise Pulleys',#4249,$,$); +#4251=IFCCLASSIFICATIONREFERENCE($,'23-21 33 00','Industrial and Manufacturing Equipment and Furnishings',#3628,$,$); +#4252=IFCCLASSIFICATIONREFERENCE($,'23-21 33 11','Manufacturing Equipment',#4251,$,$); +#4253=IFCCLASSIFICATIONREFERENCE($,'23-21 33 13','Manufacturing Furniture',#4251,$,$); +#4254=IFCCLASSIFICATIONREFERENCE($,'23-21 33 13 11','Flat Work Surface Furniture',#4253,$,$); +#4255=IFCCLASSIFICATIONREFERENCE($,'23-21 33 13 13','Work Stations',#4253,$,$); +#4256=IFCCLASSIFICATIONREFERENCE($,'23-21 33 15','Shop Equipment',#4251,$,$); +#4257=IFCCLASSIFICATIONREFERENCE($,'23-21 33 17','Shop Furniture',#4251,$,$); +#4258=IFCCLASSIFICATIONREFERENCE($,'23-21 33 17 11','Shop Work Surfaces',#4257,$,$); +#4259=IFCCLASSIFICATIONREFERENCE($,'23-21 33 17 13','Shop Storage Fittings',#4257,$,$); +#4260=IFCCLASSIFICATIONREFERENCE($,'23-21 35 00','Miscellaneous Equipment and Furnishings',#3628,$,$); +#4261=IFCCLASSIFICATIONREFERENCE($,'23-21 35 11','Darkroom Equipment and Furnishings',#4260,$,$); +#4262=IFCCLASSIFICATIONREFERENCE($,'23-21 35 11 11','Darkroom Processing Equipment',#4261,$,$); +#4263=IFCCLASSIFICATIONREFERENCE($,'23-21 35 13','Vending Equipment',#4260,$,$); +#4264=IFCCLASSIFICATIONREFERENCE($,'23-21 35 13 11','Vending Machines',#4263,$,$); +#4265=IFCCLASSIFICATIONREFERENCE($,'23-21 35 15','Ticket Machines',#4260,$,$); +#4266=IFCCLASSIFICATIONREFERENCE($,'23-21 35 17','Change Machines',#4260,$,$); +#4267=IFCCLASSIFICATIONREFERENCE($,'23-21 35 19','Vehicle Service Equipment',#4260,$,$); +#4268=IFCCLASSIFICATIONREFERENCE($,'23-21 35 19 11','Compressed Air Vehicle Service Equipment',#4267,$,$); +#4269=IFCCLASSIFICATIONREFERENCE($,'23-21 35 19 13','Fuel Dispensing Equipment',#4267,$,$); +#4270=IFCCLASSIFICATIONREFERENCE($,'23-21 35 19 15','Vehicle Lubrication Equipment',#4267,$,$); +#4271=IFCCLASSIFICATIONREFERENCE($,'23-21 35 19 17','Tire Changing Equipment',#4267,$,$); +#4272=IFCCLASSIFICATIONREFERENCE($,'23-21 35 19 19','Vehicle Washing Equipment',#4267,$,$); +#4273=IFCCLASSIFICATIONREFERENCE($,'23-21 35 19 21','Vehicle Hoists',#4267,$,$); +#4274=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21','Security and Vault Equipment and Furnishings',#4260,$,$); +#4275=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 11','Safes',#4274,$,$); +#4276=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 13','Safe Deposit Boxes',#4274,$,$); +#4277=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 15','Vault Doors',#4274,$,$); +#4278=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 17','Day Gates',#4274,$,$); +#4279=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 19','Anti Bandit Screens',#4274,$,$); +#4280=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 19 11','Gun Ports',#4279,$,$); +#4281=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 21','Teller and Service Equipment',#4274,$,$); +#4282=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 21 11','Automated Banking Systems',#4281,$,$); +#4283=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 21 13','Money Cart Pass Through',#4281,$,$); +#4284=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 21 15','Package Transfer Units',#4281,$,$); +#4285=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 21 17','Service and Teller Window Units',#4281,$,$); +#4286=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 21 19','Teller Equipment Systems',#4281,$,$); +#4287=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 21 21','Deal Drawers',#4281,$,$); +#4288=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 23','Key Security Cabinets',#4274,$,$); +#4289=IFCCLASSIFICATIONREFERENCE($,'23-21 35 21 25','Money Handling Equipment',#4274,$,$); +#4290=IFCCLASSIFICATIONREFERENCE($,'23-21 35 23','Detention Equipment and Furnishings',#4260,$,$); +#4291=IFCCLASSIFICATIONREFERENCE($,'23-21 35 23 11','Detention Enclosures',#4290,$,$); +#4292=IFCCLASSIFICATIONREFERENCE($,'23-21 35 23 13','Detention Furnishings and Specialties',#4290,$,$); +#4293=IFCCLASSIFICATIONREFERENCE($,'23-21 35 23 15','Detention Furniture',#4290,$,$); +#4294=IFCCLASSIFICATIONREFERENCE($,'23-21 35 25','Agricultural Equipment',#4260,$,$); +#4295=IFCCLASSIFICATIONREFERENCE($,'23-21 35 25 11','Milkers',#4294,$,$); +#4296=IFCCLASSIFICATIONREFERENCE($,'23-21 35 25 13','Stock Feeders',#4294,$,$); +#4297=IFCCLASSIFICATIONREFERENCE($,'23-21 35 25 15','Stock Waterers',#4294,$,$); +#4298=IFCCLASSIFICATIONREFERENCE($,'23-21 35 25 17','Waste Clean Up Equipment',#4294,$,$); +#4299=IFCCLASSIFICATIONREFERENCE($,'23-21 37 00','Furnishings, Ornaments, and Decoration',#3628,$,$); +#4300=IFCCLASSIFICATIONREFERENCE($,'23-21 37 11','Soft Furnishings',#4299,$,$); +#4301=IFCCLASSIFICATIONREFERENCE($,'23-21 37 11 11','Rugs',#4300,$,$); +#4302=IFCCLASSIFICATIONREFERENCE($,'23-21 37 11 13','Upholstery',#4300,$,$); +#4303=IFCCLASSIFICATIONREFERENCE($,'23-21 37 11 15','Cushions',#4300,$,$); +#4304=IFCCLASSIFICATIONREFERENCE($,'23-21 37 11 17','Padding',#4300,$,$); +#4305=IFCCLASSIFICATIONREFERENCE($,'23-21 37 11 19','Tablecloths',#4300,$,$); +#4306=IFCCLASSIFICATIONREFERENCE($,'23-21 37 13','Decoration',#4299,$,$); +#4307=IFCCLASSIFICATIONREFERENCE($,'23-21 37 13 11','Commercial Artwork',#4306,$,$); +#4308=IFCCLASSIFICATIONREFERENCE($,'23-21 37 13 11 11','Wall Hangings',#4307,$,$); +#4309=IFCCLASSIFICATIONREFERENCE($,'23-21 37 13 13','Clocks',#4306,$,$); +#4310=IFCCLASSIFICATIONREFERENCE($,'23-21 37 13 15','Mirrors',#4306,$,$); +#4311=IFCCLASSIFICATIONREFERENCE($,'23-21 37 13 17','Interior Ornamental Fountains',#4306,$,$); +#4312=IFCCLASSIFICATIONREFERENCE($,'23-21 37 13 19','Ornamental Screens',#4306,$,$); +#4313=IFCCLASSIFICATIONREFERENCE($,'23-21 37 13 21','Decorative Planters',#4306,$,$); +#4314=IFCCLASSIFICATIONREFERENCE($,'23-21 37 13 23','Decorative Vases',#4306,$,$); +#4315=IFCCLASSIFICATIONREFERENCE($,'23-21 39 00','Commercial Washing and Waste Disposal Equipment',#3628,$,$); +#4316=IFCCLASSIFICATIONREFERENCE($,'23-21 39 11','Commercial Washing Equipment',#4315,$,$); +#4317=IFCCLASSIFICATIONREFERENCE($,'23-21 39 11 11','High Pressure Washing Equipment',#4316,$,$); +#4318=IFCCLASSIFICATIONREFERENCE($,'23-21 39 13','Drain Boards',#4315,$,$); +#4319=IFCCLASSIFICATIONREFERENCE($,'23-21 41 00','Commercial Laundry Equipment',#3628,$,$); +#4320=IFCCLASSIFICATIONREFERENCE($,'23-21 41 11','Commercial Clothes Airers',#4319,$,$); +#4321=IFCCLASSIFICATIONREFERENCE($,'23-21 41 11 11','Commercial Clothes Dryers',#4320,$,$); +#4322=IFCCLASSIFICATIONREFERENCE($,'23-21 41 11 13','Commercial Clothes Stands',#4320,$,$); +#4323=IFCCLASSIFICATIONREFERENCE($,'23-21 41 11 15','Commercial Clothes Lines',#4320,$,$); +#4324=IFCCLASSIFICATIONREFERENCE($,'23-21 41 13','Commercial Combination Laundry Washer Dryers',#4319,$,$); +#4325=IFCCLASSIFICATIONREFERENCE($,'23-21 41 15','Commercial Dry Cleaning Equipment',#4319,$,$); +#4326=IFCCLASSIFICATIONREFERENCE($,'23-21 41 17','Commercial Laundry Dispensers',#4319,$,$); +#4327=IFCCLASSIFICATIONREFERENCE($,'23-21 41 17 11','Commercial Dry Laundry Detergent Dispensers',#4326,$,$); +#4328=IFCCLASSIFICATIONREFERENCE($,'23-21 41 17 13','Commercial Liquid Laundry Detergent Dispensers',#4326,$,$); +#4329=IFCCLASSIFICATIONREFERENCE($,'23-21 41 17 15','Commercial Dryer Sheet Dispensers',#4326,$,$); +#4330=IFCCLASSIFICATIONREFERENCE($,'23-21 41 19','Commercial Dry Cleaning Machines',#4319,$,$); +#4331=IFCCLASSIFICATIONREFERENCE($,'23-21 41 21','Commercial Laundry Extractors',#4319,$,$); +#4332=IFCCLASSIFICATIONREFERENCE($,'23-21 41 23','Commercial Flat Work Ironers',#4319,$,$); +#4333=IFCCLASSIFICATIONREFERENCE($,'23-21 41 23 11','Commercial Electric Flat Work Ironers',#4332,$,$); +#4334=IFCCLASSIFICATIONREFERENCE($,'23-21 41 23 13','Commercial Gas Flat Work Ironers',#4332,$,$); +#4335=IFCCLASSIFICATIONREFERENCE($,'23-21 41 23 15','Commercial Steam Flat Work Ironers',#4332,$,$); +#4336=IFCCLASSIFICATIONREFERENCE($,'23-21 41 25','Commercial Ironing and Pressing Machines',#4319,$,$); +#4337=IFCCLASSIFICATIONREFERENCE($,'23-21 41 27','Commercial Laundry Folding Machines',#4319,$,$); +#4338=IFCCLASSIFICATIONREFERENCE($,'23-21 41 29','Commercial Laundry Conveyors',#4319,$,$); +#4339=IFCCLASSIFICATIONREFERENCE($,'23-21 41 31','Commercial Laundry Dryers',#4319,$,$); +#4340=IFCCLASSIFICATIONREFERENCE($,'23-21 41 31 11','Commercial Electric Laundry Dryers',#4339,$,$); +#4341=IFCCLASSIFICATIONREFERENCE($,'23-21 41 31 13','Commercial Gas Laundry Dryers',#4339,$,$); +#4342=IFCCLASSIFICATIONREFERENCE($,'23-21 41 31 15','Commercial Steam Laundry Dryers',#4339,$,$); +#4343=IFCCLASSIFICATIONREFERENCE($,'23-21 41 33','Commercial Laundry Presses',#4319,$,$); +#4344=IFCCLASSIFICATIONREFERENCE($,'23-21 41 33 11','Commercial Electric Laundry Presses',#4343,$,$); +#4345=IFCCLASSIFICATIONREFERENCE($,'23-21 41 33 13','Commercial Gas Laundry Presses',#4343,$,$); +#4346=IFCCLASSIFICATIONREFERENCE($,'23-21 41 33 15','Commercial Steam Laundry Presses',#4343,$,$); +#4347=IFCCLASSIFICATIONREFERENCE($,'23-21 41 35','Commercial Laundry Spreader Feeders',#4319,$,$); +#4348=IFCCLASSIFICATIONREFERENCE($,'23-21 41 37','Commercial Laundry Steam Tunnels',#4319,$,$); +#4349=IFCCLASSIFICATIONREFERENCE($,'23-21 41 39','Commercial Laundry Tubs',#4319,$,$); +#4350=IFCCLASSIFICATIONREFERENCE($,'23-21 41 41','Commercial Washing Machines',#4319,$,$); +#4351=IFCCLASSIFICATIONREFERENCE($,'23-21 41 41 11','Commercial Front Loading Laundry Washers',#4350,$,$); +#4352=IFCCLASSIFICATIONREFERENCE($,'23-21 41 41 13','Commercial Side Loading Laundry Washers',#4350,$,$); +#4353=IFCCLASSIFICATIONREFERENCE($,'23-21 41 41 15','Commercial Top Loading Laundry Washers',#4350,$,$); +#4354=IFCCLASSIFICATIONREFERENCE($,'23-21 41 41 17','Commercial Tunnel Laundry Washers',#4350,$,$); +#4355=IFCCLASSIFICATIONREFERENCE($,'23-21 43 00','Cleaning Equipment',#3628,$,$); +#4356=IFCCLASSIFICATIONREFERENCE($,'23-21 43 11','Buckets',#4355,$,$); +#4357=IFCCLASSIFICATIONREFERENCE($,'23-21 43 11 11','Mop Buckets',#4356,$,$); +#4358=IFCCLASSIFICATIONREFERENCE($,'23-21 43 11 13','Waste Paper Baskets',#4356,$,$); +#4359=IFCCLASSIFICATIONREFERENCE($,'23-21 43 13','Cleaners',#4355,$,$); +#4360=IFCCLASSIFICATIONREFERENCE($,'23-21 43 13 11','Pressure Cleaners',#4359,$,$); +#4361=IFCCLASSIFICATIONREFERENCE($,'23-21 43 13 13','Steam Cleaners',#4359,$,$); +#4362=IFCCLASSIFICATIONREFERENCE($,'23-21 43 15','Custodial Dispensers',#4355,$,$); +#4363=IFCCLASSIFICATIONREFERENCE($,'23-21 43 15 11','Air Freshener Dispensers',#4362,$,$); +#4364=IFCCLASSIFICATIONREFERENCE($,'23-21 43 15 13','Bathroom Tissue Dispensers',#4362,$,$); +#4365=IFCCLASSIFICATIONREFERENCE($,'23-21 43 15 15','Cleaning Rag Dispensers',#4362,$,$); +#4366=IFCCLASSIFICATIONREFERENCE($,'23-21 43 15 17','Facial Tissue Dispensers',#4362,$,$); +#4367=IFCCLASSIFICATIONREFERENCE($,'23-21 43 15 19','Hand Cleaner Dispensers',#4362,$,$); +#4368=IFCCLASSIFICATIONREFERENCE($,'23-21 43 15 21','Institutional Soap Dispensers',#4362,$,$); +#4369=IFCCLASSIFICATIONREFERENCE($,'23-21 43 15 23','Lotion Dispensers',#4362,$,$); +#4370=IFCCLASSIFICATIONREFERENCE($,'23-21 43 15 25','Paper Towel Dispensers',#4362,$,$); +#4371=IFCCLASSIFICATIONREFERENCE($,'23-21 43 15 27','Sanitary Goods Dispensers',#4362,$,$); +#4372=IFCCLASSIFICATIONREFERENCE($,'23-21 43 15 29','Toilet Accessories Dispensers',#4362,$,$); +#4373=IFCCLASSIFICATIONREFERENCE($,'23-21 43 15 31','Toilet Tissue Dispensers',#4362,$,$); +#4374=IFCCLASSIFICATIONREFERENCE($,'23-21 43 15 33','Urinal Accessories Dispensers',#4362,$,$); +#4375=IFCCLASSIFICATIONREFERENCE($,'23-21 43 17','Duct Cleaning Machines',#4355,$,$); +#4376=IFCCLASSIFICATIONREFERENCE($,'23-21 43 19','Floor Cleaning Equipment',#4355,$,$); +#4377=IFCCLASSIFICATIONREFERENCE($,'23-21 43 19 11','Floor Burnishers',#4376,$,$); +#4378=IFCCLASSIFICATIONREFERENCE($,'23-21 43 19 13','Floor Polishers',#4376,$,$); +#4379=IFCCLASSIFICATIONREFERENCE($,'23-21 43 19 15','Floor Scrapers',#4376,$,$); +#4380=IFCCLASSIFICATIONREFERENCE($,'23-21 43 19 17','Floor Scrubbers',#4376,$,$); +#4381=IFCCLASSIFICATIONREFERENCE($,'23-21 43 19 19','Floor Sweepers',#4376,$,$); +#4382=IFCCLASSIFICATIONREFERENCE($,'23-21 43 19 19 11','Carpet Sweepers',#4381,$,$); +#4383=IFCCLASSIFICATIONREFERENCE($,'23-21 43 19 21','Floor Washing Machines',#4376,$,$); +#4384=IFCCLASSIFICATIONREFERENCE($,'23-21 43 21','Room Cleaning Equipment',#4355,$,$); +#4385=IFCCLASSIFICATIONREFERENCE($,'23-21 43 21 11','Vacuum Cleaning Equipment',#4384,$,$); +#4386=IFCCLASSIFICATIONREFERENCE($,'23-21 43 21 11 11','Vacuum Cleaning Systems',#4385,$,$); +#4387=IFCCLASSIFICATIONREFERENCE($,'23-21 43 21 11 11 11','Centralized Vacuum Cleaning System',#4386,$,$); +#4388=IFCCLASSIFICATIONREFERENCE($,'23-21 43 21 11 13','Vacuum Cleaners',#4385,$,$); +#4389=IFCCLASSIFICATIONREFERENCE($,'23-21 43 21 11 13 11','Heavy Duty Tank Vacuum Cleaners',#4388,$,$); +#4390=IFCCLASSIFICATIONREFERENCE($,'23-21 43 21 11 13 13','Wet Dry Combination Vacuum Cleaners',#4388,$,$); +#4391=IFCCLASSIFICATIONREFERENCE($,'23-21 43 21 11 13 15','Wet Vacuum Cleaners',#4388,$,$); +#4392=IFCCLASSIFICATIONREFERENCE($,'23-21 43 21 13','Floor and Wall Cleaning',#4384,$,$); +#4393=IFCCLASSIFICATIONREFERENCE($,'23-21 43 21 15','Housekeeping Carts',#4384,$,$); +#4394=IFCCLASSIFICATIONREFERENCE($,'23-21 43 23','Sanitary Waste Receptacles',#4355,$,$); +#4395=IFCCLASSIFICATIONREFERENCE($,'23-21 43 23 11','Installed Sanitary Waste Receptacles',#4394,$,$); +#4396=IFCCLASSIFICATIONREFERENCE($,'23-21 43 23 13','Portable Sanitary Waste Receptacles',#4394,$,$); +#4397=IFCCLASSIFICATIONREFERENCE($,'23-21 43 25','Custodial Sinks',#4355,$,$); +#4398=IFCCLASSIFICATIONREFERENCE($,'23-21 43 25 11','Mop Sinks',#4397,$,$); +#4399=IFCCLASSIFICATIONREFERENCE($,'23-21 43 27','Custodial Washers',#4355,$,$); +#4400=IFCCLASSIFICATIONREFERENCE($,'23-21 43 27 11','Trash Can Pedestal Washers',#4399,$,$); +#4401=IFCCLASSIFICATIONREFERENCE($,'23-21 45 00','Historic Preservation Products',#3628,$,$); +#4402=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11','Fine Art',#4401,$,$); +#4403=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 11','Two Dimensional Art',#4402,$,$); +#4404=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 11 11','Fine Art Paintings',#4403,$,$); +#4405=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 11 13','Fine Art Drawings',#4403,$,$); +#4406=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 11 15','Fine Art Printmaking',#4403,$,$); +#4407=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 11 15 11','Fine Art Lithography',#4406,$,$); +#4408=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 11 15 13','Fine Art Intaglio',#4406,$,$); +#4409=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 11 15 15','Fine Art Prints',#4406,$,$); +#4410=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 11 17','Fine Art Photography',#4403,$,$); +#4411=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 11 19','Fine Art Graphic Designs',#4403,$,$); +#4412=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 11 21','Fine Art Illustrations',#4403,$,$); +#4413=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 13','Three Dimensional Art',#4402,$,$); +#4414=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 13 11','Fine Art Sculpture',#4413,$,$); +#4415=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 13 13','Fine Art Ceramics',#4413,$,$); +#4416=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 13 13 11','Fine Art Pottery',#4415,$,$); +#4417=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 13 15','Fine Art Mosaics',#4413,$,$); +#4418=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 13 15 11','Fine Art Tile',#4417,$,$); +#4419=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 13 17','Fine Art Glass',#4413,$,$); +#4420=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 13 17 11','Fine Art Stained Glass',#4419,$,$); +#4421=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 13 17 13','Fine Art Etched Glass',#4419,$,$); +#4422=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 13 19','Fine Art Architecture',#4413,$,$); +#4423=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 13 19 11','Fine Art Decorative Architecture',#4422,$,$); +#4424=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 13 21','Fine Art Textile',#4413,$,$); +#4425=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 13 21 11','Fine Art Tapestry',#4424,$,$); +#4426=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 15','Four Dimensional Art',#4402,$,$); +#4427=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 15 11','Fine Art Film',#4426,$,$); +#4428=IFCCLASSIFICATIONREFERENCE($,'23-21 45 11 15 13','Fine Art Video',#4426,$,$); +#4429=IFCCLASSIFICATIONREFERENCE($,'23-21 45 13','Historic Documents',#4401,$,$); +#4430=IFCCLASSIFICATIONREFERENCE($,'23-21 45 13 11','Historic Paper Documents',#4429,$,$); +#4431=IFCCLASSIFICATIONREFERENCE($,'23-21 45 13 13','Historic Velum Documents',#4429,$,$); +#4432=IFCCLASSIFICATIONREFERENCE($,'23-21 45 13 15','Historic Parchment Documents',#4429,$,$); +#4433=IFCCLASSIFICATIONREFERENCE($,'23-21 45 15','Historic Architectural Items',#4401,$,$); +#4434=IFCCLASSIFICATIONREFERENCE($,'23-21 45 15 11','Historic Architectural Models',#4433,$,$); +#4435=IFCCLASSIFICATIONREFERENCE($,'23-21 45 15 13','Historic Architectural Constructions',#4433,$,$); +#4436=IFCCLASSIFICATIONREFERENCE($,'23-21 45 15 15','Historic Architectural Designs',#4433,$,$); +#4437=IFCCLASSIFICATIONREFERENCE($,'23-21 45 15 17','Historic Decorative Architectures',#4433,$,$); +#4438=IFCCLASSIFICATIONREFERENCE($,'23-21 47 00','Musical Equipment',#3628,$,$); +#4439=IFCCLASSIFICATIONREFERENCE($,'23-21 47 11','Conductor Equipment',#4438,$,$); +#4440=IFCCLASSIFICATIONREFERENCE($,'23-21 47 11 11','Conductor Podium',#4439,$,$); +#4441=IFCCLASSIFICATIONREFERENCE($,'23-21 47 11 13','Conductor Platform',#4439,$,$); +#4442=IFCCLASSIFICATIONREFERENCE($,'23-21 47 13','Musical Instrument',#4438,$,$); +#4443=IFCCLASSIFICATIONREFERENCE($,'23-21 47 13 11','String Instrument',#4442,$,$); +#4444=IFCCLASSIFICATIONREFERENCE($,'23-21 47 13 11 11','Piano',#4443,$,$); +#4445=IFCCLASSIFICATIONREFERENCE($,'23-23 00 00','Conveying Systems and Material Handling Products',#1606,$,$); +#4446=IFCCLASSIFICATIONREFERENCE($,'23-23 11 00','Vertical Transportation Equipment',#4445,$,$); +#4447=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11','Elevators',#4446,$,$); +#4448=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 11','Traction Elevators',#4447,$,$); +#4449=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 11 11','Freight Traction Elevators',#4448,$,$); +#4450=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 11 13','Passenger Traction Elevators',#4448,$,$); +#4451=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 11 15','Residential Traction Elevators',#4448,$,$); +#4452=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 11 17','Service Traction Elevators',#4448,$,$); +#4453=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 13','Hydraulic Elevators',#4447,$,$); +#4454=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 13 11','Freight Hydraulic Elevators',#4453,$,$); +#4455=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 13 13','Passenger Hydraulic Elevators',#4453,$,$); +#4456=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 13 15','Residential Hydraulic Elevators',#4453,$,$); +#4457=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 13 17','Service Hydraulic Elevators',#4453,$,$); +#4458=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 15','Pneumatic Elevators',#4447,$,$); +#4459=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 15 11','Pneumatic Passenger Elevators',#4458,$,$); +#4460=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 17','Rack and Pinion Elevators',#4447,$,$); +#4461=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 19','Elevator Cabs',#4447,$,$); +#4462=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 21','Elevator Equipment and Controls',#4447,$,$); +#4463=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 21 11','Elevator Doors',#4462,$,$); +#4464=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 21 13','Elevator Controls',#4462,$,$); +#4465=IFCCLASSIFICATIONREFERENCE($,'23-23 11 11 23','Elevator Restoration Products',#4447,$,$); +#4466=IFCCLASSIFICATIONREFERENCE($,'23-23 11 13','Escalators',#4446,$,$); +#4467=IFCCLASSIFICATIONREFERENCE($,'23-23 13 00','Lifting Equipment',#4445,$,$); +#4468=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11','Lifts',#4467,$,$); +#4469=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 11','Boom Lifts',#4468,$,$); +#4470=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 13','Fork Lifts',#4468,$,$); +#4471=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 15','Man Lifts',#4468,$,$); +#4472=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 17','Patient Lifts',#4468,$,$); +#4473=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 17 11','Installed Patient Lifts',#4472,$,$); +#4474=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 17 13','Portable Patient Lifts',#4472,$,$); +#4475=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 19','Platform Lifts',#4468,$,$); +#4476=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 19 11','Elevating Platform Lifts',#4475,$,$); +#4477=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 19 13','Inclined Platform Lifts',#4475,$,$); +#4478=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 19 15','Scissor Platform Lifts',#4475,$,$); +#4479=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 21','Scaffold Lifts',#4468,$,$); +#4480=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 23','Stage Screen Lifts',#4468,$,$); +#4481=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 25','Wheel Chair Lifts',#4468,$,$); +#4482=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 25 11','Hydraulic Wheel Chair Lifts',#4481,$,$); +#4483=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 25 11 11','Hydraulic Wheel Chair Rail Lifts',#4482,$,$); +#4484=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 25 11 13','Hydraulic Wheel Chair Stair Lifts',#4482,$,$); +#4485=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 25 11 15','Hydraulic Wheel Chair Vertical Lifts',#4482,$,$); +#4486=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 25 13','Mechanical Wheel Chair Lifts',#4481,$,$); +#4487=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 25 13 11','Mechanical Wheel Chair Rail Lifts',#4486,$,$); +#4488=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 25 13 13','Mechanical Wheel Chair Stair Lifts',#4486,$,$); +#4489=IFCCLASSIFICATIONREFERENCE($,'23-23 13 11 25 13 15','Mechanical Wheel Chair Vertical Lifts',#4486,$,$); +#4490=IFCCLASSIFICATIONREFERENCE($,'23-23 15 00','Horizontal Transportation Equipment',#4445,$,$); +#4491=IFCCLASSIFICATIONREFERENCE($,'23-23 15 11','Moving Walks',#4490,$,$); +#4492=IFCCLASSIFICATIONREFERENCE($,'23-23 15 13','People Movers',#4490,$,$); +#4493=IFCCLASSIFICATIONREFERENCE($,'23-23 15 13 11','Monorails',#4492,$,$); +#4494=IFCCLASSIFICATIONREFERENCE($,'23-23 15 13 13','Duorails',#4492,$,$); +#4495=IFCCLASSIFICATIONREFERENCE($,'23-23 15 13 15','Maglevs',#4492,$,$); +#4496=IFCCLASSIFICATIONREFERENCE($,'23-23 15 15','Jetways',#4490,$,$); +#4497=IFCCLASSIFICATIONREFERENCE($,'23-23 15 17','Transportation Gangways',#4490,$,$); +#4498=IFCCLASSIFICATIONREFERENCE($,'23-23 17 00','Materials Handling',#4445,$,$); +#4499=IFCCLASSIFICATIONREFERENCE($,'23-23 17 11','Dumbwaiters',#4498,$,$); +#4500=IFCCLASSIFICATIONREFERENCE($,'23-23 17 11 11','Manual Dumbwaiters',#4499,$,$); +#4501=IFCCLASSIFICATIONREFERENCE($,'23-23 17 11 13','Hydraulic Dumbwaiters',#4499,$,$); +#4502=IFCCLASSIFICATIONREFERENCE($,'23-23 17 11 15','Traction Dumbwaiters',#4499,$,$); +#4503=IFCCLASSIFICATIONREFERENCE($,'23-23 17 13','Material Transport',#4498,$,$); +#4504=IFCCLASSIFICATIONREFERENCE($,'23-23 17 13 11','Automated Document Filing and Retrieval',#4503,$,$); +#4505=IFCCLASSIFICATIONREFERENCE($,'23-23 17 13 13','Automated Guided Vehicles',#4503,$,$); +#4506=IFCCLASSIFICATIONREFERENCE($,'23-23 17 13 13 11','Guided Vehicle Material Handling',#4505,$,$); +#4507=IFCCLASSIFICATIONREFERENCE($,'23-23 17 13 13 13','Track Vehicle Material Handling',#4505,$,$); +#4508=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15','Conveyors',#4498,$,$); +#4509=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 11','Conveyor Components',#4508,$,$); +#4510=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 11 11','Conveyor Belts',#4509,$,$); +#4511=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 11 13','Conveyor Rollers',#4509,$,$); +#4512=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 13','Belt Conveyors',#4508,$,$); +#4513=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 15','Bucket Conveyors',#4508,$,$); +#4514=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 17','Container Conveyors',#4508,$,$); +#4515=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 19','Hopper and Track Conveyors',#4508,$,$); +#4516=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 21','Monorail Conveyors',#4508,$,$); +#4517=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 23','Oscillating Conveyors',#4508,$,$); +#4518=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 25','Pneumatic Conveyors',#4508,$,$); +#4519=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 27','Roller Conveyors',#4508,$,$); +#4520=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 29','Scoop Conveyors',#4508,$,$); +#4521=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 31','Screw Conveyors',#4508,$,$); +#4522=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 33','Selective Vertical Conveyors',#4508,$,$); +#4523=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 35','Postal Conveyors',#4508,$,$); +#4524=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 37','Baggage Conveying and Dispensing Equipment',#4508,$,$); +#4525=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 37 11','Baggage Conveyors',#4524,$,$); +#4526=IFCCLASSIFICATIONREFERENCE($,'23-23 17 15 37 13','Baggage Dispensing Units',#4524,$,$); +#4527=IFCCLASSIFICATIONREFERENCE($,'23-23 17 17','Chutes',#4498,$,$); +#4528=IFCCLASSIFICATIONREFERENCE($,'23-23 17 17 11','Coal Chutes',#4527,$,$); +#4529=IFCCLASSIFICATIONREFERENCE($,'23-23 17 17 13','Dry Bulk Materials Chutes',#4527,$,$); +#4530=IFCCLASSIFICATIONREFERENCE($,'23-23 17 17 15','Laundry and Linen Chutes',#4527,$,$); +#4531=IFCCLASSIFICATIONREFERENCE($,'23-23 17 17 17','Package Chutes',#4527,$,$); +#4532=IFCCLASSIFICATIONREFERENCE($,'23-23 17 17 19','Refuse Chutes',#4527,$,$); +#4533=IFCCLASSIFICATIONREFERENCE($,'23-23 17 19','Feeder Equipment',#4498,$,$); +#4534=IFCCLASSIFICATIONREFERENCE($,'23-23 17 19 11','Apron Feeders',#4533,$,$); +#4535=IFCCLASSIFICATIONREFERENCE($,'23-23 17 19 13','Reciprocating Plate Feeders',#4533,$,$); +#4536=IFCCLASSIFICATIONREFERENCE($,'23-23 17 19 15','Rotary Airlock Feeders',#4533,$,$); +#4537=IFCCLASSIFICATIONREFERENCE($,'23-23 17 19 17','Rotary Flow Feeders',#4533,$,$); +#4538=IFCCLASSIFICATIONREFERENCE($,'23-23 17 19 19','Vibratory Feeders',#4533,$,$); +#4539=IFCCLASSIFICATIONREFERENCE($,'23-23 17 21','Pneumatic Tube Systems',#4498,$,$); +#4540=IFCCLASSIFICATIONREFERENCE($,'23-23 17 21 11','Pneumatic Tubes',#4539,$,$); +#4541=IFCCLASSIFICATIONREFERENCE($,'23-23 17 21 13','Pneumatic Tube Controls',#4539,$,$); +#4542=IFCCLASSIFICATIONREFERENCE($,'23-23 17 21 15','Pneumatic Tube Vacuum Boxes',#4539,$,$); +#4543=IFCCLASSIFICATIONREFERENCE($,'23-23 17 21 17','Document Conveying Systems',#4539,$,$); +#4544=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23','Cranes',#4498,$,$); +#4545=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 11','Hydraulic Cranes',#4544,$,$); +#4546=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 11 11','Hydraulic Bridge Cranes',#4545,$,$); +#4547=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 11 11 11','Top Running Hydraulic Overhead Cranes',#4546,$,$); +#4548=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 11 11 13','Underslung Hydraulic Overhead Cranes',#4546,$,$); +#4549=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 11 13','Hydraulic Gantry Cranes',#4545,$,$); +#4550=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 11 15','Hydraulic Jib Cranes',#4545,$,$); +#4551=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 11 17','Hydraulic Mobile Cranes',#4545,$,$); +#4552=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 11 19','Hydraulic Terrain Cranes',#4545,$,$); +#4553=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 11 21','Hydraulic Top Running Overhead Cranes',#4545,$,$); +#4554=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 11 23','Hydraulic Tower Cranes',#4545,$,$); +#4555=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 11 25','Hydraulic Track Cranes',#4545,$,$); +#4556=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 11 27','Hydraulic Underslung Overhead Cranes',#4545,$,$); +#4557=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 11 29','Hydraulic Workshop Cranes',#4545,$,$); +#4558=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 13','Mechanical Cranes',#4544,$,$); +#4559=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 13 11','Mechanical Bridge Cranes',#4558,$,$); +#4560=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 13 11 11','Top Running Mechanical Overhead Cranes',#4559,$,$); +#4561=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 13 11 13','Underslung Mechanical Overhead Cranes',#4559,$,$); +#4562=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 13 13','Mechanical Gantry Cranes',#4558,$,$); +#4563=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 13 15','Mechanical Jib Cranes',#4558,$,$); +#4564=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 13 17','Mechanical Mobile Cranes',#4558,$,$); +#4565=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 13 19','Mechanical Terrain Cranes',#4558,$,$); +#4566=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 13 21','Mechanical Top Running Overhead Cranes',#4558,$,$); +#4567=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 13 23','Mechanical Tower Cranes',#4558,$,$); +#4568=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 13 25','Mechanical Track Cranes',#4558,$,$); +#4569=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 13 27','Mechanical Underslung Overhead Cranes',#4558,$,$); +#4570=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 13 29','Mechanical Workshop Cranes',#4558,$,$); +#4571=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 15','Electric Cranes',#4544,$,$); +#4572=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 15 11','Electric Bridge Cranes',#4571,$,$); +#4573=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 15 13','Top Running Electric Overhead Cranes',#4571,$,$); +#4574=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 15 15','Underslung Electric Overhead Cranes',#4571,$,$); +#4575=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 15 17','Electric Gantry Cranes',#4571,$,$); +#4576=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 15 19','Electric Jib Cranes',#4571,$,$); +#4577=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 15 21','Electric Mobile Cranes',#4571,$,$); +#4578=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 15 23','Electric Terrain Cranes',#4571,$,$); +#4579=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 15 25','Electric Top Running Overhead Cranes',#4571,$,$); +#4580=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 15 27','Electric Tower Cranes',#4571,$,$); +#4581=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 15 29','Electric Track Cranes',#4571,$,$); +#4582=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 15 31','Electric Underslung Overhead Cranes',#4571,$,$); +#4583=IFCCLASSIFICATIONREFERENCE($,'23-23 17 23 15 33','Electric Workshop Cranes',#4571,$,$); +#4584=IFCCLASSIFICATIONREFERENCE($,'23-23 17 25','Derricks',#4498,$,$); +#4585=IFCCLASSIFICATIONREFERENCE($,'23-23 17 27','Hoists',#4498,$,$); +#4586=IFCCLASSIFICATIONREFERENCE($,'23-23 17 27 11','Fixed Hoists',#4585,$,$); +#4587=IFCCLASSIFICATIONREFERENCE($,'23-23 17 27 11 11','Pneumatic Fixed Hoists',#4586,$,$); +#4588=IFCCLASSIFICATIONREFERENCE($,'23-23 17 27 11 13','Electric Fixed Hoists',#4586,$,$); +#4589=IFCCLASSIFICATIONREFERENCE($,'23-23 17 27 11 15','Manual Fixed Hoists',#4586,$,$); +#4590=IFCCLASSIFICATIONREFERENCE($,'23-23 17 27 11 17','Hydraulic Fixed Hoists',#4586,$,$); +#4591=IFCCLASSIFICATIONREFERENCE($,'23-23 17 27 13','Trolley Hoists',#4585,$,$); +#4592=IFCCLASSIFICATIONREFERENCE($,'23-23 17 27 13 11','Pneumatic Trolley Hoists',#4591,$,$); +#4593=IFCCLASSIFICATIONREFERENCE($,'23-23 17 27 13 13','Electric Trolley Hoists',#4591,$,$); +#4594=IFCCLASSIFICATIONREFERENCE($,'23-23 17 27 13 15','Manual Trolley Hoists',#4591,$,$); +#4595=IFCCLASSIFICATIONREFERENCE($,'23-23 17 27 13 17','Hydraulic Trolley Hoists',#4591,$,$); +#4596=IFCCLASSIFICATIONREFERENCE($,'23-23 19 00','Turntables',#4445,$,$); +#4597=IFCCLASSIFICATIONREFERENCE($,'23-23 19 11','Stage Turntables',#4596,$,$); +#4598=IFCCLASSIFICATIONREFERENCE($,'23-23 19 13','Exhibit and Display Turntables',#4596,$,$); +#4599=IFCCLASSIFICATIONREFERENCE($,'23-23 19 15','Vehicular Turntable',#4596,$,$); +#4600=IFCCLASSIFICATIONREFERENCE($,'23-23 21 00','Parking Systems',#4445,$,$); +#4601=IFCCLASSIFICATIONREFERENCE($,'23-23 21 11','Car Parking Systems',#4600,$,$); +#4602=IFCCLASSIFICATIONREFERENCE($,'23-23 23 00','Loading Dock Equipment',#4445,$,$); +#4603=IFCCLASSIFICATIONREFERENCE($,'23-23 23 11','Loading Dock Bumpers Seals',#4602,$,$); +#4604=IFCCLASSIFICATIONREFERENCE($,'23-23 23 13','Dock Levelers',#4602,$,$); +#4605=IFCCLASSIFICATIONREFERENCE($,'23-23 23 13 11','Powered Dock Levelers',#4604,$,$); +#4606=IFCCLASSIFICATIONREFERENCE($,'23-23 23 13 13','Manual Dock Levelers',#4604,$,$); +#4607=IFCCLASSIFICATIONREFERENCE($,'23-23 23 13 15','Hydraulic Dock Levelers',#4604,$,$); +#4608=IFCCLASSIFICATIONREFERENCE($,'23-23 23 15','Loading Dock Lifts',#4602,$,$); +#4609=IFCCLASSIFICATIONREFERENCE($,'23-23 23 15 11','Powered Loading Dock Lifts',#4608,$,$); +#4610=IFCCLASSIFICATIONREFERENCE($,'23-23 23 15 13','Manual Loading Dock Lifts',#4608,$,$); +#4611=IFCCLASSIFICATIONREFERENCE($,'23-23 23 17','Loading Dock Ramps And Bridges',#4602,$,$); +#4612=IFCCLASSIFICATIONREFERENCE($,'23-23 23 17 11','Portable Loading Dock Ramps',#4611,$,$); +#4613=IFCCLASSIFICATIONREFERENCE($,'23-23 23 17 13','Portable Loading Dock Bridges',#4611,$,$); +#4614=IFCCLASSIFICATIONREFERENCE($,'23-23 23 17 15','Portable Loading Dock Platforms',#4611,$,$); +#4615=IFCCLASSIFICATIONREFERENCE($,'23-23 23 19','Loading Dock Seals',#4602,$,$); +#4616=IFCCLASSIFICATIONREFERENCE($,'23-23 23 19 11','Inflatable Loading Dock Seals',#4615,$,$); +#4617=IFCCLASSIFICATIONREFERENCE($,'23-23 23 19 13','Loading Dock Weather Seals',#4615,$,$); +#4618=IFCCLASSIFICATIONREFERENCE($,'23-23 23 21','Loading Dock Shelters',#4602,$,$); +#4619=IFCCLASSIFICATIONREFERENCE($,'23-23 23 23','Loading Dock Vehicle Restraints',#4602,$,$); +#4620=IFCCLASSIFICATIONREFERENCE($,'23-23 23 23 11','Electric Loading Dock Vehicle Restraints',#4619,$,$); +#4621=IFCCLASSIFICATIONREFERENCE($,'23-23 23 23 13','Electro Magnetic Loading Dock Vehicle Restraints',#4619,$,$); +#4622=IFCCLASSIFICATIONREFERENCE($,'23-23 23 23 15','Hydraulic Loading Dock Vehicle Restraints',#4619,$,$); +#4623=IFCCLASSIFICATIONREFERENCE($,'23-23 25 00','Scaffolding',#4445,$,$); +#4624=IFCCLASSIFICATIONREFERENCE($,'23-23 25 11','Suspended Scaffolding',#4623,$,$); +#4625=IFCCLASSIFICATIONREFERENCE($,'23-23 25 11 11','Beam Suspended Scaffolding',#4624,$,$); +#4626=IFCCLASSIFICATIONREFERENCE($,'23-23 25 11 13','Carriage Suspended Scaffolding',#4624,$,$); +#4627=IFCCLASSIFICATIONREFERENCE($,'23-23 25 11 15','Hook Suspended Scaffolding',#4624,$,$); +#4628=IFCCLASSIFICATIONREFERENCE($,'23-23 25 13','Scaffolding Rope Climbers',#4623,$,$); +#4629=IFCCLASSIFICATIONREFERENCE($,'23-23 25 13 11','Scaffolding Manual Rope Climbers',#4628,$,$); +#4630=IFCCLASSIFICATIONREFERENCE($,'23-23 25 13 13','Scaffolding Powered Rope Climbers',#4628,$,$); +#4631=IFCCLASSIFICATIONREFERENCE($,'23-23 25 15','Scaffolding Telescoping Platforms',#4623,$,$); +#4632=IFCCLASSIFICATIONREFERENCE($,'23-23 25 15 11','Electric and Battery Scaffolding Telescoping Platforms',#4631,$,$); +#4633=IFCCLASSIFICATIONREFERENCE($,'23-23 25 15 13','Pneumatic Scaffolding Telescoping Platforms',#4631,$,$); +#4634=IFCCLASSIFICATIONREFERENCE($,'23-23 25 17','Powered Scaffolding',#4623,$,$); +#4635=IFCCLASSIFICATIONREFERENCE($,'23-25 00 00','Medical and Laboratory Equipment',#1606,$,$); +#4636=IFCCLASSIFICATIONREFERENCE($,'23-25 11 00','Anesthesiology and Respiratory Products',#4635,$,$); +#4637=IFCCLASSIFICATIONREFERENCE($,'23-25 11 11','Anesthesiology Furnishings',#4636,$,$); +#4638=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13','Anesthesiology Equipment',#4636,$,$); +#4639=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 11','Anesthesia Carts',#4638,$,$); +#4640=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 13','Anesthesia Gas Equipment',#4638,$,$); +#4641=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 15','Anesthesia Absorber Units',#4638,$,$); +#4642=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 17','Anesthesia Temperature Control Units',#4638,$,$); +#4643=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 19','Anesthesia Intrathecal Pumps',#4638,$,$); +#4644=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 21','Anesthesia Equipment Calibrators',#4638,$,$); +#4645=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 23','Anesthesia Inhalation Analgesia Units',#4638,$,$); +#4646=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 23 11','Anesthesia Inhalation Analgesia Central Gases and Vacuum Units',#4645,$,$); +#4647=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 23 13','Anesthesia Inhalation Analgesia Central Vacuum Only Units',#4645,$,$); +#4648=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 25','Respiratory Monitoring Products',#4638,$,$); +#4649=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 25 11','Apnea Monitors',#4648,$,$); +#4650=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 25 13','Arterial Blood Gas Monitors',#4648,$,$); +#4651=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 25 15','Carbon Dioxide End Tidal Monitors',#4648,$,$); +#4652=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 25 17','Esophageal Motility Recording Units',#4648,$,$); +#4653=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 25 19','Esophageal Stethoscopes',#4648,$,$); +#4654=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 25 21','Oxygen Analyzers',#4648,$,$); +#4655=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 25 23','Oxygen Monitors',#4648,$,$); +#4656=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 25 25','Respiratory Monitoring Kits',#4648,$,$); +#4657=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27','Pulmonary Function Products',#4638,$,$); +#4658=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 11','Bedside Pulmonary Function Screeners',#4657,$,$); +#4659=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 13','Body Plethysmographs',#4657,$,$); +#4660=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 15','Pneumotachs',#4657,$,$); +#4661=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 15 11','Lilly Pneumotachs',#4660,$,$); +#4662=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 15 13','Fleisch Pneumotachs',#4660,$,$); +#4663=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 17','Pulmonary Calibration Devices',#4657,$,$); +#4664=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 19','Pulmonary Function Calculators',#4657,$,$); +#4665=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 21','Pulmonary Function With Computer Analyzers',#4657,$,$); +#4666=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 23','Pulmonary Gas Analyzers',#4657,$,$); +#4667=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 25','Pulmonary Gas Monitors',#4657,$,$); +#4668=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 27','Pulmonary Peak Flowmeters',#4657,$,$); +#4669=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 29','Pulmonary Pressure Monitors',#4657,$,$); +#4670=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 31','Pulmonary Ventilation Monitors',#4657,$,$); +#4671=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 33','Respiratory Temperature Monitors',#4657,$,$); +#4672=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 35','Sleep Study Monitors',#4657,$,$); +#4673=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 37','Spirometers',#4657,$,$); +#4674=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 37 11','Diagnostic Spirometers',#4673,$,$); +#4675=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 37 13','Monitoring Spirometers',#4673,$,$); +#4676=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 27 37 15','Therapeutic Spirometers',#4673,$,$); +#4677=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 29','Oxygen Delivery Products',#4638,$,$); +#4678=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 29 11','Oxygen Concentrators',#4677,$,$); +#4679=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 29 13','Oxygen Air Blenders',#4677,$,$); +#4680=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 29 15','Oxygen Timers',#4677,$,$); +#4681=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 29 17','Oxygen Compressors',#4677,$,$); +#4682=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 29 19','Medical Oxygen Head Hoods',#4677,$,$); +#4683=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 29 21','Medical Oxygen Aerosol Tents',#4677,$,$); +#4684=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 29 23','Medical Hyperbaric Chambers',#4677,$,$); +#4685=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 29 25','Medical Inhalators',#4677,$,$); +#4686=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 29 27','Oxygen Therapy Delivery Equipment',#4677,$,$); +#4687=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 29 29','Medical Oxygen Insufflators',#4677,$,$); +#4688=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 29 31','Liquid Oxygen Converters',#4677,$,$); +#4689=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 31','Airway Management Products',#4638,$,$); +#4690=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 31 11','Airway Pressure Gages',#4689,$,$); +#4691=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 31 13','Pharyngometers',#4689,$,$); +#4692=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 33','Intubation Products',#4638,$,$); +#4693=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 33 11','Laryngoscopes',#4692,$,$); +#4694=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 33 13','Intubation Benders',#4692,$,$); +#4695=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 33 15','Intubation Gauges',#4692,$,$); +#4696=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 33 17','Carbon Dioxide Patient Detectors',#4692,$,$); +#4697=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 33 19','Intubation Suction Pumps',#4692,$,$); +#4698=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 35','Negative Pressure Ventilators',#4638,$,$); +#4699=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 35 11','Iron Lungs',#4698,$,$); +#4700=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 35 13','Chest Cuirass Products',#4698,$,$); +#4701=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 37','Positive Pressure Ventilators',#4638,$,$); +#4702=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 37 11','Intermittent Positive Pressure Breathing Ventilator Units',#4701,$,$); +#4703=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 37 13','Non Invasive Continuous Positive Air Pressure Ventilator Units',#4701,$,$); +#4704=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 37 15','Non Invasive Bi Level Ventilator Units',#4701,$,$); +#4705=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 37 17','Transport Ventilators',#4701,$,$); +#4706=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 37 19','Adult Intensive Care Ventilators',#4701,$,$); +#4707=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 37 21','High Frequency Ventilators',#4701,$,$); +#4708=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 37 23','Home Care Ventilators',#4701,$,$); +#4709=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 37 25','Positive End Expiratory Pressure Ventilator Valves',#4701,$,$); +#4710=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 37 27','Ventilator Water Traps',#4701,$,$); +#4711=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 37 29','Ventilator Gas Sampling Ports',#4701,$,$); +#4712=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 37 31','Ventilator Heat Exchangers',#4701,$,$); +#4713=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 37 33','Ventilator Moisture Exchangers',#4701,$,$); +#4714=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 39','Resuscitation Products',#4638,$,$); +#4715=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 39 11','Manual Resuscitators',#4714,$,$); +#4716=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 39 13','Pneumatic Resuscitators',#4714,$,$); +#4717=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 39 15','Electro Mechanical Resuscitators',#4714,$,$); +#4718=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 41','Lung Fluid Products',#4638,$,$); +#4719=IFCCLASSIFICATIONREFERENCE($,'23-25 11 13 41 11','Pleural Cavity Drainage Units',#4718,$,$); +#4720=IFCCLASSIFICATIONREFERENCE($,'23-25 11 15','Anesthesiology Prefabricated Structures',#4636,$,$); +#4721=IFCCLASSIFICATIONREFERENCE($,'23-25 11 15 11','Anesthesiology Gas Columns',#4720,$,$); +#4722=IFCCLASSIFICATIONREFERENCE($,'23-25 13 00','Audiology Products',#4635,$,$); +#4723=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11','Audiology Equipment',#4722,$,$); +#4724=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 11','Audiometers',#4723,$,$); +#4725=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 11 11','Diagnostic Audiometers',#4724,$,$); +#4726=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 11 13','Group Screening Audiometers',#4724,$,$); +#4727=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 11 15','Middle Ear Impedance Diagnostic Audiometers',#4724,$,$); +#4728=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 13','Audiometric Bone Vibrators',#4723,$,$); +#4729=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 15','Middle Ear Analyzers',#4723,$,$); +#4730=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 17','Auditory Function Screening Units',#4723,$,$); +#4731=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 19','Auditory Test Graphic Recorders',#4723,$,$); +#4732=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 21','Auditory Analyzers',#4723,$,$); +#4733=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 21 11','Evoked Potential Auditory Analyzers',#4732,$,$); +#4734=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 23','Ear Fenestrometers',#4723,$,$); +#4735=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 25','Electrocochleographs',#4723,$,$); +#4736=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 27','Hearing Aides',#4723,$,$); +#4737=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 29','Hearing Aid Analyzers',#4723,$,$); +#4738=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 31','Tinnitus Analyzers',#4723,$,$); +#4739=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 33','Toynbee Diagnostic Tubes',#4723,$,$); +#4740=IFCCLASSIFICATIONREFERENCE($,'23-25 13 11 35','Tympanometers',#4723,$,$); +#4741=IFCCLASSIFICATIONREFERENCE($,'23-25 13 13','Audiology Prefabricated Structures',#4722,$,$); +#4742=IFCCLASSIFICATIONREFERENCE($,'23-25 13 13 11','Audio Booths',#4741,$,$); +#4743=IFCCLASSIFICATIONREFERENCE($,'23-25 13 13 13','Double Wall Audio Booths',#4741,$,$); +#4744=IFCCLASSIFICATIONREFERENCE($,'23-25 13 13 13 11','Definitive Test Double Wall Audio Booths',#4743,$,$); +#4745=IFCCLASSIFICATIONREFERENCE($,'23-25 13 13 15','Single Wall Audio Booths',#4741,$,$); +#4746=IFCCLASSIFICATIONREFERENCE($,'23-25 13 13 17','Acoustic Hearing Test Chambers',#4741,$,$); +#4747=IFCCLASSIFICATIONREFERENCE($,'23-25 15 00','Autopsy and Postmortem Products',#4635,$,$); +#4748=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11','Autopsy and Postmortem Furnishings',#4747,$,$); +#4749=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 11','Postmortem Refrigerators and Freezers',#4748,$,$); +#4750=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 11 11','Cadaver Cabinet Refrigerators',#4749,$,$); +#4751=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 11 13','Cadaver Freezers',#4749,$,$); +#4752=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 11 15','Cadaver Refrigerated Rooms',#4749,$,$); +#4753=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 11 17','Cadaver Refrigerators',#4749,$,$); +#4754=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 11 19','Cadaver Walk In Refrigerators',#4749,$,$); +#4755=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 13','Autopsy Tables',#4748,$,$); +#4756=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 13 11','Autopsy Body Boards',#4755,$,$); +#4757=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 13 13','Autopsy Dissecting Tank Tables',#4755,$,$); +#4758=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 13 15','Autopsy Head Rests',#4755,$,$); +#4759=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 13 17','Autopsy Sinks',#4755,$,$); +#4760=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 13 19','Mobile Autopsy Tables',#4755,$,$); +#4761=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 13 21','Stationary Autopsy Tables',#4755,$,$); +#4762=IFCCLASSIFICATIONREFERENCE($,'23-25 15 11 15','Embalming Sinks',#4748,$,$); +#4763=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13','Autopsy and Postmortem Equipment',#4747,$,$); +#4764=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 11','Cadaver Lifts',#4763,$,$); +#4765=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 11 11','Cadaver Electric Lifts',#4764,$,$); +#4766=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 11 13','Cadaver Hydraulic Lifts',#4764,$,$); +#4767=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 11 15','Cadaver Scissor Lift Trolleys',#4764,$,$); +#4768=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 13','Autopsy Equipment',#4763,$,$); +#4769=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 13 11','Autopsy Fluid Collection Vacuum Aspirators',#4768,$,$); +#4770=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 13 13','Autopsy Hanging Scales',#4768,$,$); +#4771=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 13 15','Autopsy Saws',#4768,$,$); +#4772=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 13 17','Bone Dust Collectors',#4768,$,$); +#4773=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 15','Cadaver Transport And Storage Products',#4763,$,$); +#4774=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 15 11','Autopsy Carts',#4773,$,$); +#4775=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 15 13','Body Transport Containers',#4773,$,$); +#4776=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 15 15','Cadaver Carriers',#4773,$,$); +#4777=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 15 17','Cadaver Lifter Or Transfer Devices',#4773,$,$); +#4778=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 15 19','Cadaver Storage Cabinets',#4773,$,$); +#4779=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 15 21','Cadaver Storage Racks',#4773,$,$); +#4780=IFCCLASSIFICATIONREFERENCE($,'23-25 15 13 15 23','Cadaver Trays',#4773,$,$); +#4781=IFCCLASSIFICATIONREFERENCE($,'23-25 15 15','Autopsy and Postmortem Prefabricated Structures',#4747,$,$); +#4782=IFCCLASSIFICATIONREFERENCE($,'23-25 15 15 11','Autopsy Workstations',#4781,$,$); +#4783=IFCCLASSIFICATIONREFERENCE($,'23-25 15 15 11 11','Autopsy Grossing Workstations',#4782,$,$); +#4784=IFCCLASSIFICATIONREFERENCE($,'23-25 15 15 11 13','Embalming Workstations',#4782,$,$); +#4785=IFCCLASSIFICATIONREFERENCE($,'23-25 15 15 11 15','Autopsy Down Draft Workstations',#4782,$,$); +#4786=IFCCLASSIFICATIONREFERENCE($,'23-25 15 17','Autopsy and Postmortem Devices',#4747,$,$); +#4787=IFCCLASSIFICATIONREFERENCE($,'23-25 17 00','Dental Products',#4635,$,$); +#4788=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11','Dental Furnishings',#4787,$,$); +#4789=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 11','Dental Cabinets',#4788,$,$); +#4790=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 11 11','Mobile Dental Cabinets',#4789,$,$); +#4791=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 11 13','Dental Operating Stool',#4789,$,$); +#4792=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 13','Dental Examination Chairs',#4788,$,$); +#4793=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 15','Dental Stools',#4788,$,$); +#4794=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 17','Dental Cabinets',#4788,$,$); +#4795=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 19','Dental Tables',#4788,$,$); +#4796=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 21','Dental Combination Furniture Sets',#4788,$,$); +#4797=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 23','Dental Impression Water Baths',#4788,$,$); +#4798=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 25','Dental Lighting Products',#4788,$,$); +#4799=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 25 11','Dental Fiber Optic Lights',#4798,$,$); +#4800=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 25 13','Dental Operating Illumination Sets',#4798,$,$); +#4801=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 25 15','Dental Operating Light Tripods',#4798,$,$); +#4802=IFCCLASSIFICATIONREFERENCE($,'23-25 17 11 25 17','General Dental Lights',#4798,$,$); +#4803=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13','Dental Equipment',#4787,$,$); +#4804=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 11','Dental Furnaces',#4803,$,$); +#4805=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 11 11','Dental Burnout Laboratory Furnaces',#4804,$,$); +#4806=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 11 13','Porcelain Glazing Laboratory Furnaces',#4804,$,$); +#4807=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 11 15','Vacuum Porcelain Furnaces',#4804,$,$); +#4808=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 13','Dental Specialized Hoods',#4803,$,$); +#4809=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 13 11','Dental Acrylic Floor Standing Fume Hoods',#4808,$,$); +#4810=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 13 13','Dental Fishmouth Hoods',#4808,$,$); +#4811=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 13 15','Dental Splash Hoods',#4808,$,$); +#4812=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 13 17','Dental Splash Hoods with Shield',#4808,$,$); +#4813=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15','Dental Procedure Products',#4803,$,$); +#4814=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 01','Calcium Hydroxide Placement Tools',#4813,$,$); +#4815=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 03','Composite Placement Tools',#4813,$,$); +#4816=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 05','Crown Or Bridge Removers',#4813,$,$); +#4817=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 07','Dental Amalgam Carvers',#4813,$,$); +#4818=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 09','Dental Amalgamator',#4813,$,$); +#4819=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 11','Dental Anesthesia Sets',#4813,$,$); +#4820=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 13','Dental Bur Holders',#4813,$,$); +#4821=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 15','Dental Burnishers',#4813,$,$); +#4822=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 17','Dental Burs',#4813,$,$); +#4823=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 19','Dental Calipers',#4813,$,$); +#4824=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 21','Dental Cryosurgical Units',#4813,$,$); +#4825=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 23','Dental Dehydrators',#4813,$,$); +#4826=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 25','Dental Depth Gauges',#4813,$,$); +#4827=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 27','Dental Drills',#4813,$,$); +#4828=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 29','Dental Elevators',#4813,$,$); +#4829=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 31','Dental Excavators',#4813,$,$); +#4830=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 33','Dental Expanders',#4813,$,$); +#4831=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 35','Dental Filler Contouring Instruments',#4813,$,$); +#4832=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 37','Dental Fracture Detecting Tools',#4813,$,$); +#4833=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 39','Dental Gages',#4813,$,$); +#4834=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 41','Dental Guides',#4813,$,$); +#4835=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 43','Dental Heat Carriers',#4813,$,$); +#4836=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 45','Dental Hygiene Instruments',#4813,$,$); +#4837=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 47','Dental Instrument Cassettes',#4813,$,$); +#4838=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 49','Dental Instrument Sharpening Equipment',#4813,$,$); +#4839=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 51','Dental Instrument Trays',#4813,$,$); +#4840=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 53','Dental Instruments Mats',#4813,$,$); +#4841=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 55','Dental Lasers',#4813,$,$); +#4842=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 57','Dental Mallets',#4813,$,$); +#4843=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 59','Dental Mixing Slabs',#4813,$,$); +#4844=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 61','Dental Nippers',#4813,$,$); +#4845=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 63','Dental Operative Brushes',#4813,$,$); +#4846=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 65','Dental Oral Suction Devices',#4813,$,$); +#4847=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 67','Dental Pin Benders',#4813,$,$); +#4848=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 69','Dental Pin Drivers',#4813,$,$); +#4849=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 71','Dental Placement Instruments',#4813,$,$); +#4850=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 73','Dental Pulp Testers',#4813,$,$); +#4851=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 75','Dental Reamers',#4813,$,$); +#4852=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 77','Dental Retraction Cord Packing Instruments',#4813,$,$); +#4853=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 79','Dental Retractors',#4813,$,$); +#4854=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 81','Dental Saliva Ejectors',#4813,$,$); +#4855=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 83','Dental Scalers',#4813,$,$); +#4856=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 85','Dental Spreaders',#4813,$,$); +#4857=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 87','Dental Tooth Separators',#4813,$,$); +#4858=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 89','Dental Vitality Testers',#4813,$,$); +#4859=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 91','Dentoscopes',#4813,$,$); +#4860=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 93','Intraoral Lights',#4813,$,$); +#4861=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 95','Pneumatic Dental Chisels',#4813,$,$); +#4862=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 15 97','Temporomandibular Joint (TMJ) Dental Videoscopes',#4813,$,$); +#4863=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 17','Dental Tanks',#4803,$,$); +#4864=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 17 11','Dental Blow Out Tanks',#4863,$,$); +#4865=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 17 13','Dental Curing Tanks',#4863,$,$); +#4866=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 17 15','Dental Washout Blow Out Tanks',#4863,$,$); +#4867=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 19','Dental Polishing and Grinding Machines',#4803,$,$); +#4868=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 19 11','Dental Combination Grinding and Polishing Machines',#4867,$,$); +#4869=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 19 13','Dental Grinding Machines',#4867,$,$); +#4870=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 19 15','Dental Polishing Machines',#4867,$,$); +#4871=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21','Dental Imaging Products',#4803,$,$); +#4872=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21 11','Cephalometric Radiographic Fluoroscopic Units',#4871,$,$); +#4873=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21 13','Dental Film Processors',#4871,$,$); +#4874=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21 15','Dental Radioactive Tracers',#4871,$,$); +#4875=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21 17','Dental Radiographic Fluoroscopic Units',#4871,$,$); +#4876=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21 17 11','Panographic Cephalo Dental Radiographic Fluoroscopic Units',#4875,$,$); +#4877=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21 17 13','Panographic Dental Radiographic Fluoroscopic Units',#4875,$,$); +#4878=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21 19','Dental Radiography Film Analyzers',#4871,$,$); +#4879=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21 21','Dental Radiology Film Hangers',#4871,$,$); +#4880=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21 23','Dental Radiology Film Holders',#4871,$,$); +#4881=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21 25','Dental Radiology Film Mounts',#4871,$,$); +#4882=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21 27','Dental X Ray Duplicators',#4871,$,$); +#4883=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21 29','Dental X Ray Units',#4871,$,$); +#4884=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 21 31','Dental X Ray Viewers',#4871,$,$); +#4885=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 23','Dental Sterilization Products',#4803,$,$); +#4886=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 23 11','Dental Steam Cleaners',#4885,$,$); +#4887=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25','Dental Laboratory Products',#4803,$,$); +#4888=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 11','Dental Air Abrasion Units',#4887,$,$); +#4889=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 13','Dental Burners',#4887,$,$); +#4890=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 15','Dental Casting Machines',#4887,$,$); +#4891=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 17','Dental Curing Units',#4887,$,$); +#4892=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 17 11','2 Stage Dental Curing Units',#4891,$,$); +#4893=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 17 13','3 Stage Dental Curing Units',#4891,$,$); +#4894=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 19','Dental Dust Collectors',#4887,$,$); +#4895=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 21','Dental Gold Platers',#4887,$,$); +#4896=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 23','Dental Lathes',#4887,$,$); +#4897=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 25','Dental Model Trimmers',#4887,$,$); +#4898=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 27','Dental Models',#4887,$,$); +#4899=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 29','Dental Plaster Traps',#4887,$,$); +#4900=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 31','Dental Resin Curing Units',#4887,$,$); +#4901=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 31 11','Dental Visible Light Resin Curing Units',#4900,$,$); +#4902=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 33','Dental Resins Processing Units',#4887,$,$); +#4903=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 35','Dental Sandblasters',#4887,$,$); +#4904=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 37','Dental Soldering Machines',#4887,$,$); +#4905=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 39','Dental Torches',#4887,$,$); +#4906=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 41','Dental Vacuum Units',#4887,$,$); +#4907=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 43','Dental Vibrators',#4887,$,$); +#4908=IFCCLASSIFICATIONREFERENCE($,'23-25 17 13 25 45','Dental Waxing Units',#4887,$,$); +#4909=IFCCLASSIFICATIONREFERENCE($,'23-25 17 15','Dental Prefabricated Structures',#4787,$,$); +#4910=IFCCLASSIFICATIONREFERENCE($,'23-25 17 15 11','Dental Lab Workcenters',#4909,$,$); +#4911=IFCCLASSIFICATIONREFERENCE($,'23-25 17 15 11 11','Dental Lab Die Trimming Workcenters',#4910,$,$); +#4912=IFCCLASSIFICATIONREFERENCE($,'23-25 17 15 11 13','Dental Lab Equipment Workcenters',#4910,$,$); +#4913=IFCCLASSIFICATIONREFERENCE($,'23-25 17 15 11 15','Dental Lab Metal Grinding Workcenters',#4910,$,$); +#4914=IFCCLASSIFICATIONREFERENCE($,'23-25 17 15 11 17','Dental Lab Microblasting Workcenters',#4910,$,$); +#4915=IFCCLASSIFICATIONREFERENCE($,'23-25 17 15 11 19','Dental Lab Plaster Workcenters',#4910,$,$); +#4916=IFCCLASSIFICATIONREFERENCE($,'23-25 17 15 11 21','Dental Lab Polishing Workcenters',#4910,$,$); +#4917=IFCCLASSIFICATIONREFERENCE($,'23-25 17 15 11 23','Dental Lab Surveying and Milling Workcenters',#4910,$,$); +#4918=IFCCLASSIFICATIONREFERENCE($,'23-25 19 00','Dermatology Products',#4635,$,$); +#4919=IFCCLASSIFICATIONREFERENCE($,'23-25 19 11','Dermatology Furnishings',#4918,$,$); +#4920=IFCCLASSIFICATIONREFERENCE($,'23-25 19 13','Dermatology Equipment',#4918,$,$); +#4921=IFCCLASSIFICATIONREFERENCE($,'23-25 19 13 11','Phototherapy Products',#4920,$,$); +#4922=IFCCLASSIFICATIONREFERENCE($,'23-25 19 13 11 11','Phototherapy Air Circulators',#4921,$,$); +#4923=IFCCLASSIFICATIONREFERENCE($,'23-25 19 13 11 13','Phototherapy Blankets',#4921,$,$); +#4924=IFCCLASSIFICATIONREFERENCE($,'23-25 19 13 11 15','Phototherapy Light Mats',#4921,$,$); +#4925=IFCCLASSIFICATIONREFERENCE($,'23-25 19 13 11 17','Phototherapy Patient Protection Devices',#4921,$,$); +#4926=IFCCLASSIFICATIONREFERENCE($,'23-25 19 13 11 19','Phototherapy Power Units',#4921,$,$); +#4927=IFCCLASSIFICATIONREFERENCE($,'23-25 19 13 11 21','Phototherapy Warmer Beds',#4921,$,$); +#4928=IFCCLASSIFICATIONREFERENCE($,'23-25 19 15','Dermatology Prefabricated Structures',#4918,$,$); +#4929=IFCCLASSIFICATIONREFERENCE($,'23-25 19 15 11','Ultraviolet Treatment Booths',#4928,$,$); +#4930=IFCCLASSIFICATIONREFERENCE($,'23-25 19 15 13','Hand and Foot Ultraviolet Treatment Booths',#4928,$,$); +#4931=IFCCLASSIFICATIONREFERENCE($,'23-25 19 17','Dermatology Devices',#4918,$,$); +#4932=IFCCLASSIFICATIONREFERENCE($,'23-25 21 00','Emergency Trauma and Intensive Care Products',#4635,$,$); +#4933=IFCCLASSIFICATIONREFERENCE($,'23-25 21 11','Emergency Trauma and Intensive Furnishings',#4932,$,$); +#4934=IFCCLASSIFICATIONREFERENCE($,'23-25 21 11 11','Catheter Storage Cabinets',#4933,$,$); +#4935=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13','Emergency Trauma and Intensive Equipment',#4932,$,$); +#4936=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 11','Emergency Carts',#4935,$,$); +#4937=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 13','Emergency Transportation Products',#4935,$,$); +#4938=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 13 11','Air Evacuation Stretchers',#4937,$,$); +#4939=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 13 13','Ambulance Cots',#4937,$,$); +#4940=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 13 15','Anti Shock Garments',#4937,$,$); +#4941=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 13 17','Basket Stretchers',#4937,$,$); +#4942=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 13 19','Scoop Stretchers',#4937,$,$); +#4943=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 13 21','Spine Boards',#4937,$,$); +#4944=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 13 23','Water Rescue Tubes',#4937,$,$); +#4945=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 15','Emergency Airway Management Products',#4935,$,$); +#4946=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 15 11','Emergency Laryngoscope Kits',#4945,$,$); +#4947=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 15 13','Emergency Oropharyngeal Airway Devices',#4945,$,$); +#4948=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 15 15','Emergency Suction Units',#4945,$,$); +#4949=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 15 17','Emergency Tracheal Tube Kits',#4945,$,$); +#4950=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 17','Emergency Kits',#4935,$,$); +#4951=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 17 11','Emergency Dental Kits',#4950,$,$); +#4952=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 17 13','Emergency First Aid Kits',#4950,$,$); +#4953=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 17 15','Emergency Fracture Kits',#4950,$,$); +#4954=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 17 17','Emergency Intravenous IV Kits',#4950,$,$); +#4955=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 17 19','Emergency Medical First Response Kits',#4950,$,$); +#4956=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 17 21','Emergency Medical Technician Kits',#4950,$,$); +#4957=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 17 23','Emergency Obstetrics Kits',#4950,$,$); +#4958=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 17 25','Emergency Resuscitation Kits',#4950,$,$); +#4959=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 17 27','Emergency Services Trauma Kits',#4950,$,$); +#4960=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 17 29','Emergency Ventriculostomy Kits',#4950,$,$); +#4961=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 19','Emergency Resuscitation Products',#4935,$,$); +#4962=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 19 11','Diefibrillators',#4961,$,$); +#4963=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 19 11 11','Acute Care Defibrillators',#4962,$,$); +#4964=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 19 11 13','Acute Care Defibrillator With Monitors',#4962,$,$); +#4965=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 19 11 15','Automatic Defibrillators',#4962,$,$); +#4966=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 19 11 17','Defibrillator with Cardioscopes',#4962,$,$); +#4967=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 19 11 19','Portable Defibrillators',#4962,$,$); +#4968=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 19 13','Defibrillator Analyzers',#4961,$,$); +#4969=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 19 15','Emergency Aspirators',#4961,$,$); +#4970=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 19 17','Emergency Resuscitators',#4961,$,$); +#4971=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 19 17 11','Emergency Manual Resuscitators',#4970,$,$); +#4972=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 19 17 13','Emergency Pulmonary Resuscitators',#4970,$,$); +#4973=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 19 17 15','Emergency Oxygen Powered Resuscitators',#4970,$,$); +#4974=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 21','Acute Care Monitoring Units',#4935,$,$); +#4975=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 21 11','Acute Care Fetal Monitoring Units',#4974,$,$); +#4976=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 21 13','Acute Care Maternal Monitoring Units',#4974,$,$); +#4977=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 21 15','Cardiac Output Monitoring Units',#4974,$,$); +#4978=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 21 17','Intracranial Pressure Monitoring Units',#4974,$,$); +#4979=IFCCLASSIFICATIONREFERENCE($,'23-25 21 13 21 19','Multiparameter Vital Sign Units',#4974,$,$); +#4980=IFCCLASSIFICATIONREFERENCE($,'23-25 21 15','Emergency Trauma and Intensive Prefabricated Structures',#4932,$,$); +#4981=IFCCLASSIFICATIONREFERENCE($,'23-25 21 15 11','Intensive Care Unit Prefabricated Service Columns',#4980,$,$); +#4982=IFCCLASSIFICATIONREFERENCE($,'23-25 21 15 13','Trauma Workcenters',#4980,$,$); +#4983=IFCCLASSIFICATIONREFERENCE($,'23-25 23 00','Endocrinology Products',#4635,$,$); +#4984=IFCCLASSIFICATIONREFERENCE($,'23-25 23 11','Endocrinology Furnishings',#4983,$,$); +#4985=IFCCLASSIFICATIONREFERENCE($,'23-25 23 11 11','Dialysis Chairs',#4984,$,$); +#4986=IFCCLASSIFICATIONREFERENCE($,'23-25 23 11 13','Dialysis Tables',#4984,$,$); +#4987=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13','Endocrinology Equipment',#4983,$,$); +#4988=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 11','Peritoneal Dialysis Products',#4987,$,$); +#4989=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 11 11','Continuous Ambulatory Peritoneal Dialysis Transfer Units',#4988,$,$); +#4990=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 11 13','Dialysis Boxes',#4988,$,$); +#4991=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 11 15','Pheresis Units',#4988,$,$); +#4992=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 11 17','Peritoneal Dialysis Units',#4988,$,$); +#4993=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 11 17 11','Hollow Peritoneal Dialysis Units',#4992,$,$); +#4994=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13','Hemodialysis Products',#4987,$,$); +#4995=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 11','Hemodialysis Blood Oxygen Demand Units',#4994,$,$); +#4996=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 13','Hemodialysis Conductivity Meters',#4994,$,$); +#4997=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 15','Hemodialysis Filters',#4994,$,$); +#4998=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 17','Hemodialysis Level Detectors',#4994,$,$); +#4999=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 19','Hemodialysis Pressure Pumps',#4994,$,$); +#5000=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 21','Hemodialysis Reprocessing Units',#4994,$,$); +#5001=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 23','Hemodialysis Tanks',#4994,$,$); +#5002=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 25','Hemodialysis Unit Arterial Pressure Monitors',#4994,$,$); +#5003=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 27','Hemodialysis Unit Blood Pumps',#4994,$,$); +#5004=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 29','Hemodialysis Unit Heparin Infusion Pumps',#4994,$,$); +#5005=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 31','Hemodialysis Unit Single Pass Converters',#4994,$,$); +#5006=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 33','Hemodialysis Unit Stands',#4994,$,$); +#5007=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 35','Hemodialysis Unit Temperature Monitors',#4994,$,$); +#5008=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 37','Hemodialysis Unit Test Equipment',#4994,$,$); +#5009=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 39','Hemodialysis Units',#4994,$,$); +#5010=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 13 41','Hemodialysis Warming Baths',#4994,$,$); +#5011=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 15','Continuous Renal Replacement Therapy Products',#4987,$,$); +#5012=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 15 11','Continuous Arteriovenous Dialysis Units',#5011,$,$); +#5013=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 15 13','Continuous Arteriovenous Hemofiltration Units',#5011,$,$); +#5014=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 15 15','Continuous Venovenous Hemodialysis Units',#5011,$,$); +#5015=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 15 17','Continuous Venovenous Hemofiltration Units',#5011,$,$); +#5016=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 15 19','Renal Dialysis Cartridge Flushing Units',#5011,$,$); +#5017=IFCCLASSIFICATIONREFERENCE($,'23-25 23 13 15 21','Slow Continuous Ultrafiltration Units',#5011,$,$); +#5018=IFCCLASSIFICATIONREFERENCE($,'23-25 23 15','Endocrinology Prefabricated Structures',#4983,$,$); +#5019=IFCCLASSIFICATIONREFERENCE($,'23-25 25 00','Gastroenterology and Hepatology Products',#4635,$,$); +#5020=IFCCLASSIFICATIONREFERENCE($,'23-25 25 11','Gastroenterology Furnishings',#5019,$,$); +#5021=IFCCLASSIFICATIONREFERENCE($,'23-25 25 11 11','Proctology Examination Tables',#5020,$,$); +#5022=IFCCLASSIFICATIONREFERENCE($,'23-25 25 11 13','Urological Procedure Table',#5020,$,$); +#5023=IFCCLASSIFICATIONREFERENCE($,'23-25 25 11 13 11','Endoscope Storage Cabinets',#5022,$,$); +#5024=IFCCLASSIFICATIONREFERENCE($,'23-25 25 11 13 13','Endoscope Wall Hangers',#5022,$,$); +#5025=IFCCLASSIFICATIONREFERENCE($,'23-25 25 11 13 15','Endoscopic Procedure Carts',#5022,$,$); +#5026=IFCCLASSIFICATIONREFERENCE($,'23-25 25 13','Gastroenterology Equipment',#5019,$,$); +#5027=IFCCLASSIFICATIONREFERENCE($,'23-25 25 15','Gastroenterology Prefabricated Structures',#5019,$,$); +#5028=IFCCLASSIFICATIONREFERENCE($,'23-25 25 17','Gastroenterology Devices',#5019,$,$); +#5029=IFCCLASSIFICATIONREFERENCE($,'23-25 27 00','General Internal Medicine Products',#4635,$,$); +#5030=IFCCLASSIFICATIONREFERENCE($,'23-25 27 11','General Internal Medicine Furnishings',#5029,$,$); +#5031=IFCCLASSIFICATIONREFERENCE($,'23-25 27 11 11','Intravenous Transport Products',#5030,$,$); +#5032=IFCCLASSIFICATIONREFERENCE($,'23-25 27 11 11 11','Intravenous Equipment Hangers',#5031,$,$); +#5033=IFCCLASSIFICATIONREFERENCE($,'23-25 27 11 11 13','Intravenous Infusion Gravity Systems Mounted Racks',#5031,$,$); +#5034=IFCCLASSIFICATIONREFERENCE($,'23-25 27 11 11 15','Intravenous Infusion Gravity Systems Mounted Tracks',#5031,$,$); +#5035=IFCCLASSIFICATIONREFERENCE($,'23-25 27 11 11 17','Intravenous Line Poles',#5031,$,$); +#5036=IFCCLASSIFICATIONREFERENCE($,'23-25 27 11 11 19','Intravenous Line Stands',#5031,$,$); +#5037=IFCCLASSIFICATIONREFERENCE($,'23-25 27 11 11 21','Intravenous Wheelchair Poles',#5031,$,$); +#5038=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13','General Internal Medicine Equipment',#5029,$,$); +#5039=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 11','Endoscopy Carts',#5038,$,$); +#5040=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 11 11','Fiberoptic Endoscopy Carts',#5039,$,$); +#5041=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 11 11 11','Basic Fiberoptic Endoscopy Carts',#5040,$,$); +#5042=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 11 11 13','Fiberoptic Endoscopy Carts With Video Accessories',#5040,$,$); +#5043=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 11 11 15','Fiberoptic Endoscopy Carts With Video Accessories And Information Management',#5040,$,$); +#5044=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 11 13','Video Endoscopy Carts',#5039,$,$); +#5045=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 11 13 11','Video Endoscopy Carts CCD Scope And Information Management',#5044,$,$); +#5046=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 13','Intravenous Pump Products',#5038,$,$); +#5047=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 13 11','General Use Intravenous Pumps',#5046,$,$); +#5048=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 13 13','Intravenous Infusion Pump Analyzers',#5046,$,$); +#5049=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 13 15','Intravenous Infusion Pump Sensors',#5046,$,$); +#5050=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 13 17','Intravenous Infusion Pump Transducers',#5046,$,$); +#5051=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 13 19','Intravenous Syringe Pumps',#5046,$,$); +#5052=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 13 21','Multichannel Intravenous Pumps',#5046,$,$); +#5053=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 15','Urological Products',#5038,$,$); +#5054=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 15 11','Cystometry Transducers',#5053,$,$); +#5055=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 15 13','Urethral Sound Sets',#5053,$,$); +#5056=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 15 15','Urethral Stone Remover Sets',#5053,$,$); +#5057=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 15 17','Urodynamic Catheters',#5053,$,$); +#5058=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 15 19','Urological Percolators',#5053,$,$); +#5059=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17','Endoscopes Products',#5038,$,$); +#5060=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 11','Rigid Endoscopes',#5059,$,$); +#5061=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 13','Flexible Endoscopes',#5059,$,$); +#5062=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 15','Cystourethroscopes',#5059,$,$); +#5063=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 17','Resectoscopes',#5059,$,$); +#5064=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 19','Laparoscopes',#5059,$,$); +#5065=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 21','Laparoscopic Telescopes',#5059,$,$); +#5066=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 23','Cystoscopes',#5059,$,$); +#5067=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 25','Endoscopic Sphincterotomes',#5059,$,$); +#5068=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 27','Duodenoscopes',#5059,$,$); +#5069=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 27 11','Combination Duodenoscope and Choledochoscopes',#5068,$,$); +#5070=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 27 13','Therapeutic Duodenoscopes',#5068,$,$); +#5071=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 27 15','Fiberoptic Therapeutic Duodenoscopes',#5068,$,$); +#5072=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 27 17','Video Therapeutic Duodenoscopes',#5068,$,$); +#5073=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 29','Esophagoscopes',#5059,$,$); +#5074=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 31','Endoscopic Equipment Sets',#5059,$,$); +#5075=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 33','Endoscopic Heater Probe Units',#5059,$,$); +#5076=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 35','Endoscopic Imaging Equipment',#5059,$,$); +#5077=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 37','Endoscopic Insufflation Units',#5059,$,$); +#5078=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 39','Endoscopic Distention Units',#5059,$,$); +#5079=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 41','Endoscopic Printers',#5059,$,$); +#5080=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 43','Endoscopic Video Cameras',#5059,$,$); +#5081=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 45','Endoscopic Recorders',#5059,$,$); +#5082=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 47','Enteroscopes',#5059,$,$); +#5083=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 47 11','Therapeutic Fiberoptic Enteroscopes',#5082,$,$); +#5084=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 17 47 13','Therapeutic Video Enteroscopes',#5082,$,$); +#5085=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 19','Gastroscope Products',#5038,$,$); +#5086=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 19 11','Therapeutic Fiberoptic Gastroscopes',#5085,$,$); +#5087=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 19 13','Therapeutic Video Gastroscopes',#5085,$,$); +#5088=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 21','Sigmoidoscope Products',#5038,$,$); +#5089=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 21 11','Therapeutic Sigmoidoscopes',#5088,$,$); +#5090=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 21 13','Fiberoptic Therapeutic Sigmoidoscopes',#5088,$,$); +#5091=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 21 15','Video Therapeutic Sigmoidoscopes',#5088,$,$); +#5092=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 23','Colonoscopy Products',#5038,$,$); +#5093=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 23 11','Mobile Colonoscope System With Accessories',#5092,$,$); +#5094=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 23 13','Therapeutic Colonoscopes',#5092,$,$); +#5095=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 23 13 11','Fiberoptic Therapeutic Colonoscopes',#5094,$,$); +#5096=IFCCLASSIFICATIONREFERENCE($,'23-25 27 13 23 13 13','Video Therapeutic Colonoscopes',#5094,$,$); +#5097=IFCCLASSIFICATIONREFERENCE($,'23-25 27 15','General Internal Medicine Prefabricated Structures',#5029,$,$); +#5098=IFCCLASSIFICATIONREFERENCE($,'23-25 29 00','Therapeutic and Physical Therapy Products',#4635,$,$); +#5099=IFCCLASSIFICATIONREFERENCE($,'23-25 29 11','Therapeutic and Physical Therapy Furnishings',#5098,$,$); +#5100=IFCCLASSIFICATIONREFERENCE($,'23-25 29 11 11','Therapeutic Baths',#5099,$,$); +#5101=IFCCLASSIFICATIONREFERENCE($,'23-25 29 11 11 11','Hydrotherapy Baths',#5100,$,$); +#5102=IFCCLASSIFICATIONREFERENCE($,'23-25 29 11 11 11 11','Body Hydrotherapy Baths',#5101,$,$); +#5103=IFCCLASSIFICATIONREFERENCE($,'23-25 29 11 11 11 13','Burn Hydrotherapy Baths',#5101,$,$); +#5104=IFCCLASSIFICATIONREFERENCE($,'23-25 29 11 11 11 15','Burn Hydrotherapy With Lift Baths',#5101,$,$); +#5105=IFCCLASSIFICATIONREFERENCE($,'23-25 29 11 11 11 17','Hydrotherapy With Elevating Tub Baths',#5101,$,$); +#5106=IFCCLASSIFICATIONREFERENCE($,'23-25 29 11 11 11 19','Sitting Hydrotherapy Baths',#5101,$,$); +#5107=IFCCLASSIFICATIONREFERENCE($,'23-25 29 11 11 13','Therapeutic Refrigerated Circulating Water Baths',#5100,$,$); +#5108=IFCCLASSIFICATIONREFERENCE($,'23-25 29 11 13','Therapeutic Tables',#5099,$,$); +#5109=IFCCLASSIFICATIONREFERENCE($,'23-25 29 11 13 11','Chiropractic Tables',#5108,$,$); +#5110=IFCCLASSIFICATIONREFERENCE($,'23-25 29 11 13 13','Therapeutic Massage Tables',#5108,$,$); +#5111=IFCCLASSIFICATIONREFERENCE($,'23-25 29 11 13 15','Traction Physical Therapy Tables',#5108,$,$); +#5112=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13','Therapeutic and Physical Therapy Equipment',#5098,$,$); +#5113=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 11','Physical Therapy Traction Equipment',#5112,$,$); +#5114=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 11 11','Traction Appliances Carts',#5113,$,$); +#5115=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13','Therapeutic Exercise Equipment',#5112,$,$); +#5116=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 11','Balance Beams',#5115,$,$); +#5117=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 13','Therapeutic Exercise Balance Boards',#5115,$,$); +#5118=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 15','Therapeutic Exercise Balance Bolsters',#5115,$,$); +#5119=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 17','Therapeutic Exercise Balance Rockers',#5115,$,$); +#5120=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 19','Therapeutic Exercise Climbing Equipment',#5115,$,$); +#5121=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 21','Therapeutic Exercise Continuous Passive Motion CPM Equipment',#5115,$,$); +#5122=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 23','Therapeutic Exercise Skates',#5115,$,$); +#5123=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 25','Therapeutic Exercise Free Weights',#5115,$,$); +#5124=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 27','Therapeutic Lung Exercisers',#5115,$,$); +#5125=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 29','Therapeutic Exercise Mats',#5115,$,$); +#5126=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 31','Therapeutic Exercise Platforms',#5115,$,$); +#5127=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 33','Therapeutic Exercise Pulleys',#5115,$,$); +#5128=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 35','Therapeutic Exercise Resistive Equipment',#5115,$,$); +#5129=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 37','Therapeutic Exercise Skateboards',#5115,$,$); +#5130=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 39','Therapeutic Exercise Therapeutic Balls',#5115,$,$); +#5131=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 41','Therapeutic Exercise Treadmills',#5115,$,$); +#5132=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 43','Therapeutic Exercise Vestibular Motion Equipment',#5115,$,$); +#5133=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 45','Therapeutic Exercise Weight Belts',#5115,$,$); +#5134=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 47','Therapeutic Exercise Weight Machines',#5115,$,$); +#5135=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 13 49','Therapeutic Exercise Wrist Exercisers',#5115,$,$); +#5136=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 15','Gait Training Products',#5112,$,$); +#5137=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 15 11','Gait Training Bars',#5136,$,$); +#5138=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 15 13','Gait Training Bikes',#5136,$,$); +#5139=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 15 15','Gait Training Parallel Bars',#5136,$,$); +#5140=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 15 17','Gait Training Ramps',#5136,$,$); +#5141=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 15 19','Gait Training Stairs',#5136,$,$); +#5142=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 15 21','Gait Training Walkers',#5136,$,$); +#5143=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 17','Electrotherapy Equipment',#5112,$,$); +#5144=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 17 11','Electrotherapy Combination Units',#5143,$,$); +#5145=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 17 13','Galvanic Stimulators',#5143,$,$); +#5146=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 17 15','Faradic Stimulators',#5143,$,$); +#5147=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 17 17','Neuromuscular Stimulators',#5143,$,$); +#5148=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 17 17 11','Multi Channel Neuromuscular Stimulators',#5147,$,$); +#5149=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 17 17 13','interferential Neuromuscular Stimulators',#5147,$,$); +#5150=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 17 17 15','Portable Neuromuscular Stimulators',#5147,$,$); +#5151=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 17 19','Therapeutic Short Wave Diathermy Units',#5143,$,$); +#5152=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 17 21','Transcutaneous Electric Nerve Stimulation Units',#5143,$,$); +#5153=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 19','Heat Cold Therapy Products',#5112,$,$); +#5154=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 19 11','Therapeutic Cold Storage Chilling Units',#5153,$,$); +#5155=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 19 13','Therapeutic Heat Lamps',#5153,$,$); +#5156=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 19 15','Therapeutic Hydrocollators',#5153,$,$); +#5157=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 19 17','Therapeutic Combination Heating Cooling Units',#5153,$,$); +#5158=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 19 19','Therapeutic Cooling Blankets',#5153,$,$); +#5159=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 19 21','Therapeutic Cooling Drapes',#5153,$,$); +#5160=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 19 23','Therapeutic Cooling Units',#5153,$,$); +#5161=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 19 25','Therapeutic Cryo Compression Equipment',#5153,$,$); +#5162=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 19 27','Therapeutic Heating Blankets',#5153,$,$); +#5163=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 19 29','Therapeutic Heating Drapes',#5153,$,$); +#5164=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 19 31','Therapeutic Heating Units',#5153,$,$); +#5165=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 19 33','Therapeutic Paraffin Baths',#5153,$,$); +#5166=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 21','Hydrotherapy Products',#5112,$,$); +#5167=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 21 11','Extremity Hydrotherapy Baths',#5166,$,$); +#5168=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 21 13','Extremity Hydrotherapy Tanks',#5166,$,$); +#5169=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 21 15','Full Body Immersion Hydrotherapy Baths',#5166,$,$); +#5170=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 21 17','Full Body Immersion Hydrotherapy Tanks',#5166,$,$); +#5171=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 21 19','Hydrotherapy Bath Chairs',#5166,$,$); +#5172=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 23','Hypothermia and Hyperthermia Units',#5112,$,$); +#5173=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 23 11','Combination Hyperthermia and Hypothermia Units',#5172,$,$); +#5174=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 23 13','Hyperthermia Units',#5172,$,$); +#5175=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 23 15','Hypothermia Units',#5172,$,$); +#5176=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 23 17','Mobile Combination Hyperthermia and Hypothermia Units',#5172,$,$); +#5177=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 23 19','Mobile Hyperthermia Units',#5172,$,$); +#5178=IFCCLASSIFICATIONREFERENCE($,'23-25 29 13 23 21','Mobile Hypothermia Units',#5172,$,$); +#5179=IFCCLASSIFICATIONREFERENCE($,'23-25 29 15','Health Exercise and Physical Therapy Prefabricated Structures',#5098,$,$); +#5180=IFCCLASSIFICATIONREFERENCE($,'23-25 29 15 11','Nourishment Stations',#5179,$,$); +#5181=IFCCLASSIFICATIONREFERENCE($,'23-25 31 00','Hematology Products',#4635,$,$); +#5182=IFCCLASSIFICATIONREFERENCE($,'23-25 31 11','Hematology Furnishings',#5181,$,$); +#5183=IFCCLASSIFICATIONREFERENCE($,'23-25 31 11 11','Blood Refrigerators and Freezers',#5182,$,$); +#5184=IFCCLASSIFICATIONREFERENCE($,'23-25 31 11 11 11','Blood Bank Refrigerators',#5183,$,$); +#5185=IFCCLASSIFICATIONREFERENCE($,'23-25 31 11 11 13','Blood Freezers',#5183,$,$); +#5186=IFCCLASSIFICATIONREFERENCE($,'23-25 31 11 11 13 11','Double Compartment Blood Freezers',#5185,$,$); +#5187=IFCCLASSIFICATIONREFERENCE($,'23-25 31 11 11 13 13','Blood Plasma Freezers',#5185,$,$); +#5188=IFCCLASSIFICATIONREFERENCE($,'23-25 31 11 11 15','Dry Tissue Freezers',#5183,$,$); +#5189=IFCCLASSIFICATIONREFERENCE($,'23-25 31 11 11 17','Plasma Storage Freezers',#5183,$,$); +#5190=IFCCLASSIFICATIONREFERENCE($,'23-25 31 11 13','Hematology Baths',#5182,$,$); +#5191=IFCCLASSIFICATIONREFERENCE($,'23-25 31 11 13 11','Serology Water Baths',#5190,$,$); +#5192=IFCCLASSIFICATIONREFERENCE($,'23-25 31 11 13 13','Tissue Processing Water Baths',#5190,$,$); +#5193=IFCCLASSIFICATIONREFERENCE($,'23-25 31 11 15','Hematology Cabinets',#5182,$,$); +#5194=IFCCLASSIFICATIONREFERENCE($,'23-25 31 11 15 11','Paraffin Block Cabinets',#5193,$,$); +#5195=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13','Hematology Equipment',#5181,$,$); +#5196=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13 11','Hematology Analyzers',#5195,$,$); +#5197=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13 11 11','Blood Lead Analyzers',#5196,$,$); +#5198=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13 11 13','BUN Analyzers',#5196,$,$); +#5199=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13 11 13 11','Discrete BUN Analyzers',#5198,$,$); +#5200=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13 11 15','PH Blood Gas Analyzers',#5196,$,$); +#5201=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13 11 17','Blood Typing Centrifuges',#5196,$,$); +#5202=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13 13','Blood And Transfusion Products',#5195,$,$); +#5203=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13 13 11','Blood Conservation Equipment',#5202,$,$); +#5204=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13 13 13','Blood Containers',#5202,$,$); +#5205=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13 13 15','Blood Transfusion Equipment',#5202,$,$); +#5206=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13 13 17','Blood Warming and Transfusion Equipment',#5202,$,$); +#5207=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13 13 19','Blood Warming Equipment',#5202,$,$); +#5208=IFCCLASSIFICATIONREFERENCE($,'23-25 31 13 13 21','Blood Waste Collection Equipment',#5202,$,$); +#5209=IFCCLASSIFICATIONREFERENCE($,'23-25 31 15','Hematology Prefabricated Structures',#5181,$,$); +#5210=IFCCLASSIFICATIONREFERENCE($,'23-25 31 15 11','Blood Bank Workcenters',#5209,$,$); +#5211=IFCCLASSIFICATIONREFERENCE($,'23-25 31 15 13','Hematology Workcenters',#5209,$,$); +#5212=IFCCLASSIFICATIONREFERENCE($,'23-25 33 00','Medical Gas Products',#4635,$,$); +#5213=IFCCLASSIFICATIONREFERENCE($,'23-25 33 11','Medical Air Pressure Control Cabinets',#5212,$,$); +#5214=IFCCLASSIFICATIONREFERENCE($,'23-25 33 13','Medical Gas Alarm Modules',#5212,$,$); +#5215=IFCCLASSIFICATIONREFERENCE($,'23-25 33 15','Medical Gas Cylinder Carts',#5212,$,$); +#5216=IFCCLASSIFICATIONREFERENCE($,'23-25 33 17','Medical Gas Cylinder Stands',#5212,$,$); +#5217=IFCCLASSIFICATIONREFERENCE($,'23-25 33 19','Medical Gas Delivery Columns',#5212,$,$); +#5218=IFCCLASSIFICATIONREFERENCE($,'23-25 33 21','Medical Gas Filtering Equipment',#5212,$,$); +#5219=IFCCLASSIFICATIONREFERENCE($,'23-25 33 23','Medical Gas Manifolds',#5212,$,$); +#5220=IFCCLASSIFICATIONREFERENCE($,'23-25 33 25','Medical Gas Outlets',#5212,$,$); +#5221=IFCCLASSIFICATIONREFERENCE($,'23-25 33 27','Medical Gas Service Tracks',#5212,$,$); +#5222=IFCCLASSIFICATIONREFERENCE($,'23-25 33 29','Medical Gas Shutoff Valves',#5212,$,$); +#5223=IFCCLASSIFICATIONREFERENCE($,'23-25 33 31','Medical Gas Treatment Equipment',#5212,$,$); +#5224=IFCCLASSIFICATIONREFERENCE($,'23-25 33 33','Medical Gas Valve Boxes',#5212,$,$); +#5225=IFCCLASSIFICATIONREFERENCE($,'23-25 35 00','Nursing Products',#4635,$,$); +#5226=IFCCLASSIFICATIONREFERENCE($,'23-25 35 11','Nursing Furnishings',#5225,$,$); +#5227=IFCCLASSIFICATIONREFERENCE($,'23-25 35 11 11','Freestanding Nursing Table Bath and Showers',#5226,$,$); +#5228=IFCCLASSIFICATIONREFERENCE($,'23-25 35 13','Nursing Equipment',#5225,$,$); +#5229=IFCCLASSIFICATIONREFERENCE($,'23-25 35 13 11','Nursing Station Telecommunications Equipment',#5228,$,$); +#5230=IFCCLASSIFICATIONREFERENCE($,'23-25 35 13 11 11','Nurse Communication Modules',#5229,$,$); +#5231=IFCCLASSIFICATIONREFERENCE($,'23-25 35 13 11 13','Nurse Intercoms',#5229,$,$); +#5232=IFCCLASSIFICATIONREFERENCE($,'23-25 35 13 11 15','Nurse Room Control Equipment',#5229,$,$); +#5233=IFCCLASSIFICATIONREFERENCE($,'23-25 35 13 11 17','Nurse Room Control Exit Monitors',#5229,$,$); +#5234=IFCCLASSIFICATIONREFERENCE($,'23-25 35 15','Nursing Prefabricated Structures',#5225,$,$); +#5235=IFCCLASSIFICATIONREFERENCE($,'23-25 35 15 11','Nurse Stations',#5234,$,$); +#5236=IFCCLASSIFICATIONREFERENCE($,'23-25 37 00','Obstetrics and Gynecology Products',#4635,$,$); +#5237=IFCCLASSIFICATIONREFERENCE($,'23-25 37 11','Obstetrics and Gynecology Furnishings',#5236,$,$); +#5238=IFCCLASSIFICATIONREFERENCE($,'23-25 37 11 11','Obstetrics and Gynecology Beds',#5237,$,$); +#5239=IFCCLASSIFICATIONREFERENCE($,'23-25 37 11 11 11','Birthing Beds',#5238,$,$); +#5240=IFCCLASSIFICATIONREFERENCE($,'23-25 37 11 11 13','Electric Birthing Beds',#5238,$,$); +#5241=IFCCLASSIFICATIONREFERENCE($,'23-25 37 11 13','Obstetrics and Gynecology Tables',#5237,$,$); +#5242=IFCCLASSIFICATIONREFERENCE($,'23-25 37 11 13 11','Beast Biopsy Tables',#5241,$,$); +#5243=IFCCLASSIFICATIONREFERENCE($,'23-25 37 11 13 13','Gynecological Exam Tables',#5241,$,$); +#5244=IFCCLASSIFICATIONREFERENCE($,'23-25 37 11 13 15','Obstetrical Examination Tables',#5241,$,$); +#5245=IFCCLASSIFICATIONREFERENCE($,'23-25 37 13','Obstetrics and Gynecology Equipment',#5236,$,$); +#5246=IFCCLASSIFICATIONREFERENCE($,'23-25 37 13 11','Obstetrics and Gynecology Carts',#5245,$,$); +#5247=IFCCLASSIFICATIONREFERENCE($,'23-25 37 13 11 11','Fetal Monitoring Carts',#5246,$,$); +#5248=IFCCLASSIFICATIONREFERENCE($,'23-25 37 13 13','Breast Biopsy Products',#5245,$,$); +#5249=IFCCLASSIFICATIONREFERENCE($,'23-25 37 13 13 11','Minimally Invasive Breast Biopsy Premium Loading Units',#5248,$,$); +#5250=IFCCLASSIFICATIONREFERENCE($,'23-25 37 13 13 13','Minimally Invasive Breast Biopsy Vacuum Units',#5248,$,$); +#5251=IFCCLASSIFICATIONREFERENCE($,'23-25 37 15','Obstetrics and Gynecology Prefabricated Structures',#5236,$,$); +#5252=IFCCLASSIFICATIONREFERENCE($,'23-25 39 00','Ophthalmology Products',#4635,$,$); +#5253=IFCCLASSIFICATIONREFERENCE($,'23-25 39 11','Ophthalmology Furnishings',#5252,$,$); +#5254=IFCCLASSIFICATIONREFERENCE($,'23-25 39 11 11','Ophthalmology Tables',#5253,$,$); +#5255=IFCCLASSIFICATIONREFERENCE($,'23-25 39 11 11 11','Ophthalmologic Instrument Tables',#5254,$,$); +#5256=IFCCLASSIFICATIONREFERENCE($,'23-25 39 11 13','Ophthalmology Cabinets',#5253,$,$); +#5257=IFCCLASSIFICATIONREFERENCE($,'23-25 39 11 13 11','Lens Measuring Instrument Cabinets',#5256,$,$); +#5258=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13','Ophthalmology Equipment',#5252,$,$); +#5259=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11','Ophthalmic Diagnostic Exam Products',#5258,$,$); +#5260=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 11','Autorefractors',#5259,$,$); +#5261=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 13','Binocular Vision Test Sets',#5259,$,$); +#5262=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 15','Chart Projectors',#5259,$,$); +#5263=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 17','Color Perception Testing Lanterns',#5259,$,$); +#5264=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 19','Combination Refractor Keratometers',#5259,$,$); +#5265=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 21','Contact Lens Gonioscope',#5259,$,$); +#5266=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 23','Corneal Topographers',#5259,$,$); +#5267=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 25','Corneal Topography Units',#5259,$,$); +#5268=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 27','Depth Perception Units',#5259,$,$); +#5269=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 29','Electronystagmographs',#5259,$,$); +#5270=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 31','Electroretinogram Systems',#5259,$,$); +#5271=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 33','Exophthalmometers',#5259,$,$); +#5272=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 35','Eye Occluders',#5259,$,$); +#5273=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 37','Keratometer Ophthalmometers',#5259,$,$); +#5274=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 39','Keratoscopes',#5259,$,$); +#5275=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 41','Ophthalmic Colorimeters',#5259,$,$); +#5276=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 43','Ophthalmic Distometers',#5259,$,$); +#5277=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 45','Ophthalmic Drums',#5259,$,$); +#5278=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 47','Ophthalmic Euthyscopes',#5259,$,$); +#5279=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 49','Ophthalmic Eye Test Lenses',#5259,$,$); +#5280=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 51','Ophthalmic Instrument Pads',#5259,$,$); +#5281=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 53','Ophthalmic Instrument Tables',#5259,$,$); +#5282=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 55','Ophthalmic Lens Holders',#5259,$,$); +#5283=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 57','Ophthalmic Lensometers',#5259,$,$); +#5284=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 57 11','Ophthalmic Soft Contract Lensometers',#5283,$,$); +#5285=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 59','Ophthalmic Perimeters',#5259,$,$); +#5286=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 61','Ophthalmic Photometers',#5259,$,$); +#5287=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 63','Ophthalmic Prisms',#5259,$,$); +#5288=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 65','Ophthalmic Retinoscope Accessories',#5259,$,$); +#5289=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 67','Ophthalmic Retinoscopes',#5259,$,$); +#5290=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 69','Ophthalmic Slit Lamps',#5259,$,$); +#5291=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 71','Ophthalmic Spectrophotometers',#5259,$,$); +#5292=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 73','Ophthalmic Speculas',#5259,$,$); +#5293=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 75','Ophthalmic Tonometers',#5259,$,$); +#5294=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 75 11','Ophthalmic Applanation Tonometers',#5293,$,$); +#5295=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 75 13','Ophthalmic Noncontact Tonometers',#5293,$,$); +#5296=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 77','Ophthalmic Transilluminators',#5259,$,$); +#5297=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 79','Ophthalmic Visual Field Plotters',#5259,$,$); +#5298=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 81','Ophthalmic Visual Function Analyzers',#5259,$,$); +#5299=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 83','Ophthalmic Visuometers',#5259,$,$); +#5300=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 85','Ophthalmodynamometers',#5259,$,$); +#5301=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 87','Ophthalmometers',#5259,$,$); +#5302=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 89','Opthalmometer Base Plates',#5259,$,$); +#5303=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 91','Pachymeters',#5259,$,$); +#5304=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 91 11','Ultrasound Pachymeters',#5303,$,$); +#5305=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 91 13','Corneal Ultrasound Pachymeters',#5303,$,$); +#5306=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 92','Phoropter Units',#5259,$,$); +#5307=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 93','Pseudoisochromatic Plate Sets',#5259,$,$); +#5308=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 94','Tachistoscopes',#5259,$,$); +#5309=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 95','Tangent Screens',#5259,$,$); +#5310=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 96','Viewing Stands For Vision Acuity Testing',#5259,$,$); +#5311=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 11 97','Vision Testing Stereoscopes',#5259,$,$); +#5312=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 13','Ophthalmic Equipment',#5258,$,$); +#5313=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 13 11','Lens Edging Machines',#5312,$,$); +#5314=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 13 11 11','Lens Edging Automatic Beveling Machines',#5313,$,$); +#5315=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 13 11 13','Lens Edging Automatic Machines',#5313,$,$); +#5316=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 13 13','Ophthalmic Lasers',#5312,$,$); +#5317=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 13 13 11','Dual Fiber Photocoagulation Ophthalmic Lasers',#5316,$,$); +#5318=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 13 13 13','Ophthalmic Laser With Ophthalmoscopes',#5316,$,$); +#5319=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 13 13 15','Ophthalmic Laser With Slit Lamps',#5316,$,$); +#5320=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 13 13 17','Semiconductor Diode Ophthalmic Lasers',#5316,$,$); +#5321=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 13 15','Phacofragmentation (Cusa) Units',#5312,$,$); +#5322=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 15','Obstetrical And Gynecological Kits',#5258,$,$); +#5323=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 15 11','Amniocentesis Kits',#5322,$,$); +#5324=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 15 13','Obstetrical Extraction Units',#5322,$,$); +#5325=IFCCLASSIFICATIONREFERENCE($,'23-25 39 13 15 15','Gynecology Drainage Kits',#5322,$,$); +#5326=IFCCLASSIFICATIONREFERENCE($,'23-25 39 15','Ophthalmology Prefabricated Structures',#5252,$,$); +#5327=IFCCLASSIFICATIONREFERENCE($,'23-25 41 00','Orthopedics Products',#4635,$,$); +#5328=IFCCLASSIFICATIONREFERENCE($,'23-25 41 11','Orthopedics Furnishings',#5327,$,$); +#5329=IFCCLASSIFICATIONREFERENCE($,'23-25 41 11 11','Orthopedics Tables',#5328,$,$); +#5330=IFCCLASSIFICATIONREFERENCE($,'23-25 41 11 11 11','Medical Casting Tables',#5329,$,$); +#5331=IFCCLASSIFICATIONREFERENCE($,'23-25 41 11 11 13','Orthopedic Operating Tables',#5329,$,$); +#5332=IFCCLASSIFICATIONREFERENCE($,'23-25 41 11 11 15','Orthopedic Fracture Operating Tables',#5329,$,$); +#5333=IFCCLASSIFICATIONREFERENCE($,'23-25 41 11 13','Orthopedics Sinks',#5328,$,$); +#5334=IFCCLASSIFICATIONREFERENCE($,'23-25 41 11 13 11','Plaster Sinks',#5333,$,$); +#5335=IFCCLASSIFICATIONREFERENCE($,'23-25 41 13','Orthopedics Equipment',#5327,$,$); +#5336=IFCCLASSIFICATIONREFERENCE($,'23-25 41 13 11','Orthopedics Carts',#5335,$,$); +#5337=IFCCLASSIFICATIONREFERENCE($,'23-25 41 13 11 11','Plaster Carts',#5336,$,$); +#5338=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15','Orthopedic And Prosthetic And Sports Medicine Products',#5327,$,$); +#5339=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 11','Casting Equipment And Products',#5338,$,$); +#5340=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 11 11','Broken Arm Casting Machines',#5339,$,$); +#5341=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 11 13','Cast Carts',#5339,$,$); +#5342=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 11 15','Cast Cutters',#5339,$,$); +#5343=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 11 17','Cast Impression Trays',#5339,$,$); +#5344=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 11 19','Cast Saws',#5339,$,$); +#5345=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 11 21','Cast Stands',#5339,$,$); +#5346=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 11 23','Cast Vacuum Units',#5339,$,$); +#5347=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 11 25','Casting Induction Machines',#5339,$,$); +#5348=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 11 27','Casting Machine Guards',#5339,$,$); +#5349=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 11 29','Chrome Cobalt Casting Machines',#5339,$,$); +#5350=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 13','Orthopedic Traction Products',#5338,$,$); +#5351=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 13 11','Mobile Traction Carts',#5350,$,$); +#5352=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 13 13','Orthopedic Traction Weights',#5350,$,$); +#5353=IFCCLASSIFICATIONREFERENCE($,'23-25 41 15 13 15','Orthopedic Upper Limb Appliances',#5350,$,$); +#5354=IFCCLASSIFICATIONREFERENCE($,'23-25 41 17','Orthopedics Prefabricated Structures',#5327,$,$); +#5355=IFCCLASSIFICATIONREFERENCE($,'23-25 43 00','Otolaryngology Products',#4635,$,$); +#5356=IFCCLASSIFICATIONREFERENCE($,'23-25 43 11','Otolaryngology Furnishings',#5355,$,$); +#5357=IFCCLASSIFICATIONREFERENCE($,'23-25 43 13','Otolaryngology Equipment',#5355,$,$); +#5358=IFCCLASSIFICATIONREFERENCE($,'23-25 43 13 11','Nasal Equipment',#5357,$,$); +#5359=IFCCLASSIFICATIONREFERENCE($,'23-25 43 13 11 11','Nasal Bleeding Control Devices',#5358,$,$); +#5360=IFCCLASSIFICATIONREFERENCE($,'23-25 43 13 11 13','Nasal Flowmeters',#5358,$,$); +#5361=IFCCLASSIFICATIONREFERENCE($,'23-25 43 13 11 15','Nasal Irrigation Devices',#5358,$,$); +#5362=IFCCLASSIFICATIONREFERENCE($,'23-25 43 13 11 17','Olfactometers',#5358,$,$); +#5363=IFCCLASSIFICATIONREFERENCE($,'23-25 43 13 11 19','Rhinoanemometers',#5358,$,$); +#5364=IFCCLASSIFICATIONREFERENCE($,'23-25 43 13 13','Taste Equipment',#5357,$,$); +#5365=IFCCLASSIFICATIONREFERENCE($,'23-25 43 13 13 11','Gustometers',#5364,$,$); +#5366=IFCCLASSIFICATIONREFERENCE($,'23-25 43 13 15','Ear Equipment',#5357,$,$); +#5367=IFCCLASSIFICATIONREFERENCE($,'23-25 43 13 15 11','Earmold Equipment',#5366,$,$); +#5368=IFCCLASSIFICATIONREFERENCE($,'23-25 43 15','Otolaryngology Prefabricated Structures',#5355,$,$); +#5369=IFCCLASSIFICATIONREFERENCE($,'23-25 45 00','Patient Care Products',#4635,$,$); +#5370=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11','Patient Care Furnishings',#5369,$,$); +#5371=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 11','Patient Beds',#5370,$,$); +#5372=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 11 11','Electric Patient Beds',#5371,$,$); +#5373=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 11 13','Electric Special Care Patient Beds',#5371,$,$); +#5374=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 11 15','Hospital Bedside Rails',#5371,$,$); +#5375=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 11 17','Hospital Head Boards',#5371,$,$); +#5376=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 13','Medical Mattresses',#5370,$,$); +#5377=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 13 11','Hospital Bed Mattresses',#5376,$,$); +#5378=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 13 13','Medical Pressure Reduction Mattresses',#5376,$,$); +#5379=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 15','Patient Baths',#5370,$,$); +#5380=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 17','Patient Showers',#5370,$,$); +#5381=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 17 11','Free Standing Patient Showers',#5380,$,$); +#5382=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 17 13','Patient\X2\2019\X0\s Combination Toilets',#5380,$,$); +#5383=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 19','Patient Seating',#5370,$,$); +#5384=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 19 11','Hospital Recliners',#5383,$,$); +#5385=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 19 13','Patient Chairs',#5383,$,$); +#5386=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 21','Physically Challenged Transport Equipment',#5370,$,$); +#5387=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 21 11','Physically Challenged Multifunctional Mobility Devices',#5386,$,$); +#5388=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 21 13','Physically Challenged Positioning Devices',#5386,$,$); +#5389=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 21 15','Physically Challenged Standing Aids',#5386,$,$); +#5390=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 21 17','Physically Challenged Whole Body Sliding Devices',#5386,$,$); +#5391=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 21 19','Physically Challenged Whole Body Turning Devices',#5386,$,$); +#5392=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 21 21','Rollators',#5386,$,$); +#5393=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 21 23','Walkers',#5386,$,$); +#5394=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 23','Physically Challenged Baths and Showers',#5370,$,$); +#5395=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 23 11','Physically Challenged Bath Chairs',#5394,$,$); +#5396=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 23 13','Physically Challenged Bath Lifts',#5394,$,$); +#5397=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 23 15','Physically Challenged Bath Safety Rails',#5394,$,$); +#5398=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 23 17','Physically Challenged Bathboards',#5394,$,$); +#5399=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 23 19','Physically Challenged Shower Seats',#5394,$,$); +#5400=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 23 21','Physically Challenged Showers',#5394,$,$); +#5401=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 23 23','Physically Challenged Sitz Baths',#5394,$,$); +#5402=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 25','Physically Challenged Baths and Showers',#5370,$,$); +#5403=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 25 11','Physically Challenged Toilet Arm Supports',#5402,$,$); +#5404=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 25 13','Physically Challenged Toilet Frames',#5402,$,$); +#5405=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 25 15','Physically Challenged Toilet Grab Bars',#5402,$,$); +#5406=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 25 17','Physically Challenged Toilet Seat Lifters',#5402,$,$); +#5407=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 25 19','Physically Challenged Toilet Seats',#5402,$,$); +#5408=IFCCLASSIFICATIONREFERENCE($,'23-25 45 11 25 21','Physically Challenged Toilets',#5402,$,$); +#5409=IFCCLASSIFICATIONREFERENCE($,'23-25 45 13','Patient Care Equipment',#5369,$,$); +#5410=IFCCLASSIFICATIONREFERENCE($,'23-25 45 15','Patient Care Prefabricated Structures',#5369,$,$); +#5411=IFCCLASSIFICATIONREFERENCE($,'23-25 47 00','Patient Clinical Diagnostic Products',#4635,$,$); +#5412=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11','Patient Clinical Diagnostic Furnishings',#5411,$,$); +#5413=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 11','Privacy Screens',#5412,$,$); +#5414=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 11 11','Patient Cubicle Curtain Tracks',#5413,$,$); +#5415=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 11 13','Patient Cubicle Curtains',#5413,$,$); +#5416=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 11 15','Patient Cubicle Screens',#5413,$,$); +#5417=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 13','Patient Clinical Diagnostic Tables',#5412,$,$); +#5418=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 13 11','Examination Treatment Tables',#5417,$,$); +#5419=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 13 13','Medical Procedure Tables',#5417,$,$); +#5420=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 13 15','Minor Surgical Tables',#5417,$,$); +#5421=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 13 17','Treatment Tables',#5417,$,$); +#5422=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 15','Patient Clinical Diagnostic Sinks',#5412,$,$); +#5423=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 15 11','Clinic Sinks',#5422,$,$); +#5424=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 15 13','Clinic Scrub Sinks',#5422,$,$); +#5425=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 17','Patient Clinical Diagnostic Storage Products',#5412,$,$); +#5426=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 17 11','Patient Records Shelving Units',#5425,$,$); +#5427=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 19','Patient Clinical Diagnostic Seating',#5412,$,$); +#5428=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 19 11','Clinical Examination Chairs',#5427,$,$); +#5429=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 19 13','Physician Stools',#5427,$,$); +#5430=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 21','Patient Clinical Diagnostic Cabinets',#5412,$,$); +#5431=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 21 11','Exam Room Cabinets',#5430,$,$); +#5432=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 21 13','Pass Through Specimen Cabinets',#5430,$,$); +#5433=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 21 15','Treatment Cabinets',#5430,$,$); +#5434=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 23','Patient Clinical Diagnostic Monitor Arms',#5412,$,$); +#5435=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 23 11','Medical Facility Monitor Ceiling Arms',#5434,$,$); +#5436=IFCCLASSIFICATIONREFERENCE($,'23-25 47 11 23 13','Medical Facility Monitor Wall Arms',#5434,$,$); +#5437=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13','Patient Clinical Diagnostic Equipment',#5411,$,$); +#5438=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 11','Blood Pressure Units And Related Products',#5437,$,$); +#5439=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 11 11','Aneroid Blood Pressure Units',#5438,$,$); +#5440=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 11 13','Aneroid Sphygmomanometers',#5438,$,$); +#5441=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 11 15','Blood Pressure Recording Units',#5438,$,$); +#5442=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 11 17','Electronic Blood Pressure Units',#5438,$,$); +#5443=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 11 19','Mercury Blood Pressure Units',#5438,$,$); +#5444=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 11 21','Sphygmomanometers',#5438,$,$); +#5445=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 13','Electrocardiography EKG Units And Related Products',#5437,$,$); +#5446=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 13 11','Electrocardiography Units',#5445,$,$); +#5447=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 13 11 11','Multiple Channel Electrocardiograph Units',#5446,$,$); +#5448=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 13 11 13','Single Channel Electrocardiograph Units',#5446,$,$); +#5449=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 13 13','Electrocardiography Cable Lead Testers',#5445,$,$); +#5450=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 13 15','Electrocardiography Graphic Recorders',#5445,$,$); +#5451=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 13 17','Electrocardiography Monitors',#5445,$,$); +#5452=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 13 19','Electrocardiography Unit Analyzers',#5445,$,$); +#5453=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 13 21','Long Term Continuous Electrocardiography Monitoring Units',#5445,$,$); +#5454=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 13 23','Electrocardiography Transmitters',#5445,$,$); +#5455=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 15','Pulse Dosimeters Products',#5437,$,$); +#5456=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 15 11','Co Oximeters',#5455,$,$); +#5457=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 15 13','Pulse Oximeter Cables',#5455,$,$); +#5458=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 15 15','Pulse Oximeter Probes',#5455,$,$); +#5459=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 15 17','Pulse Oximeter Sensors',#5455,$,$); +#5460=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 15 19','Pulse Oximeter Units',#5455,$,$); +#5461=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17','Medical Exam Diagnostic Products',#5437,$,$); +#5462=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 11','Angioscopes',#5461,$,$); +#5463=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 13','Anoscopes',#5461,$,$); +#5464=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 15','Binocular Ophthalmoscopes',#5461,$,$); +#5465=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 15 11','Direct Binocular Ophthalmoscopes',#5464,$,$); +#5466=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 15 13','Indirect Binocular Ophthalmoscopes',#5464,$,$); +#5467=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 17','Body Composition Analyzer',#5461,$,$); +#5468=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 19','Bronchoscopes',#5461,$,$); +#5469=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 21','Colposcopes',#5461,$,$); +#5470=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 23','Dermatoscopes',#5461,$,$); +#5471=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 25','Electroencephalograph EEG',#5461,$,$); +#5472=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 27','Electromyographs',#5461,$,$); +#5473=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 29','Electronic Stethoscopes',#5461,$,$); +#5474=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 31','Fiberoptic Bronchoscopes',#5461,$,$); +#5475=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 31 11','Adult Fiberoptic Bronchoscopes',#5474,$,$); +#5476=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 31 13','Adult Large Channel Fiberoptic Bronchoscopes',#5474,$,$); +#5477=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 31 15','Adult Slim Casing Fiberoptic Bronchoscopes',#5474,$,$); +#5478=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 31 17','Examination Fiberoptic Bronchoscopes',#5474,$,$); +#5479=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 31 19','Pediatric Fiberoptic Bronchoscopes',#5474,$,$); +#5480=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 31 21','Therapeutic Fiberoptic Bronchoscopes',#5474,$,$); +#5481=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 33','Goniometers',#5461,$,$); +#5482=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 35','Hand Held Vascular Dopplers',#5461,$,$); +#5483=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 37','Mechanical Stethoscopes',#5461,$,$); +#5484=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 39','Nasopharyngoscopes',#5461,$,$); +#5485=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 41','Neurological Discriminators',#5461,$,$); +#5486=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 43','Neurological Sensors',#5461,$,$); +#5487=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 45','Ophthalmoscopes',#5461,$,$); +#5488=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 47','Otoscopes',#5461,$,$); +#5489=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 49','Patient Thermoregulators',#5461,$,$); +#5490=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 51','Proctoscopes',#5461,$,$); +#5491=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 53','Stethoscopic Phonocardiographs',#5461,$,$); +#5492=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 55','Therapeutic Bronchoscopes',#5461,$,$); +#5493=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 17 57','Vaginoscopes',#5461,$,$); +#5494=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 19','Patient Weight Scales',#5437,$,$); +#5495=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 19 11','Diaper Weight Scales',#5494,$,$); +#5496=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 19 13','Infant Scales',#5494,$,$); +#5497=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 19 15','Patient Bed Scales',#5494,$,$); +#5498=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 19 17','Patient Chair Scales',#5494,$,$); +#5499=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 19 19','Patient Floor Scales',#5494,$,$); +#5500=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 19 21','Patient Sling Scales',#5494,$,$); +#5501=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 19 23','Patient Table Scales',#5494,$,$); +#5502=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 19 25','Wheelchair Platform Scales',#5494,$,$); +#5503=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21','Patient Clinical Diagnostic Analyzers',#5437,$,$); +#5504=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 11','Amino Acid Analyzers',#5503,$,$); +#5505=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 13','Bilirubinometers',#5503,$,$); +#5506=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 15','Blood Bank Analyzers',#5503,$,$); +#5507=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 17','Blood Gas Analyzers',#5503,$,$); +#5508=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 19','Blood Chemistry Analyzers',#5503,$,$); +#5509=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 21','Chemistry Analyzers',#5503,$,$); +#5510=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 23','Coagulation Analyzers',#5503,$,$); +#5511=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 23 11','Automatic Coagulation Analyzers',#5510,$,$); +#5512=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 23 13','Fibrometers',#5510,$,$); +#5513=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 25','Deoxyribonucleic Sequence Analyzers',#5503,$,$); +#5514=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 27','Toxicology Analyzers',#5503,$,$); +#5515=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 29','Hematology Analyzers',#5503,$,$); +#5516=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 29 11','Differential Hematology Analyzers',#5515,$,$); +#5517=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 31','Histology Analyzers',#5503,$,$); +#5518=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 33','Breath Hydrogen Analyzers',#5503,$,$); +#5519=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 35','Immunology Analyzers',#5503,$,$); +#5520=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 37','Microbiology Analyzers',#5503,$,$); +#5521=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 39','Protein Analyzers',#5503,$,$); +#5522=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 41','Radioisotopic Analyzers',#5503,$,$); +#5523=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 43','Urinalysis Analyzers',#5503,$,$); +#5524=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 43 11','Advanced Urinalysis Analyzers',#5523,$,$); +#5525=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 43 13','Basic Urinalysis Analyzers',#5523,$,$); +#5526=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 45','Glucose Analyzers',#5503,$,$); +#5527=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 47','Drug Screening Chemistry Analyzers',#5503,$,$); +#5528=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 49','High Capacity Strat Chemistry Analyzers',#5503,$,$); +#5529=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 51','Multichannel Chemistry Analyzer',#5503,$,$); +#5530=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 53','Stat Chemistry Analyzers',#5503,$,$); +#5531=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 55','Enzyme Immuni Assay Analysis Units',#5503,$,$); +#5532=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 55 11','Advanced Enzyme Immuni Assay Analysis Units',#5531,$,$); +#5533=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 55 13','Basic Enzyme Immuni Assay Analysis Units',#5531,$,$); +#5534=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 55 15','Plate Washer Enzyme Immuni Assay Analysis Units',#5531,$,$); +#5535=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 21 55 17','Hemoglobinometers',#5531,$,$); +#5536=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 23','Patient Clinical Testing Products',#5437,$,$); +#5537=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 23 11','Cholesterol Meters',#5536,$,$); +#5538=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 23 13','Cholesterol Monitors',#5536,$,$); +#5539=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 23 15','Glucose Meters',#5536,$,$); +#5540=IFCCLASSIFICATIONREFERENCE($,'23-25 47 13 23 17','Glucose Monitors',#5536,$,$); +#5541=IFCCLASSIFICATIONREFERENCE($,'23-25 47 15','Patient Clinical Diagnostic Prefabricated Structures',#5411,$,$); +#5542=IFCCLASSIFICATIONREFERENCE($,'23-25 47 15 11','Exam Work Centers',#5541,$,$); +#5543=IFCCLASSIFICATIONREFERENCE($,'23-25 47 15 13','Gross Pathology Stations',#5541,$,$); +#5544=IFCCLASSIFICATIONREFERENCE($,'23-25 47 15 15','Hospital equipment power columns',#5541,$,$); +#5545=IFCCLASSIFICATIONREFERENCE($,'23-25 47 15 17','Medical Preparation Work Centers',#5541,$,$); +#5546=IFCCLASSIFICATIONREFERENCE($,'23-25 49 00','Patient Transportation and Lifting Equipment',#4635,$,$); +#5547=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11','Patient transport products',#5546,$,$); +#5548=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 11','Patient Transport Trolleys',#5547,$,$); +#5549=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 13','Patient Gurneys',#5547,$,$); +#5550=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 15','Geriatric Chairs',#5547,$,$); +#5551=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 17','Patient Transport Incubators',#5547,$,$); +#5552=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 19','Patient Scooters',#5547,$,$); +#5553=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 21','Patient Stretchers',#5547,$,$); +#5554=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 21 11','Cadaver Transport Stretchers',#5553,$,$); +#5555=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 21 13','Labor Recover Stretchers',#5553,$,$); +#5556=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 21 15','MRI Compatible Stretchers',#5553,$,$); +#5557=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 21 17','Surgical Recovery Stretchers',#5553,$,$); +#5558=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 23','Patient Mobile Stretchers',#5547,$,$); +#5559=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 23 11','Tapered Head Mobile Stretchers',#5558,$,$); +#5560=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 23 13','9 Position Mobile Stretchers',#5558,$,$); +#5561=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 25','Wheelchairs',#5547,$,$); +#5562=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 25 11','Electric Wheelchairs',#5561,$,$); +#5563=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 25 13','Manual Wheelchairs',#5561,$,$); +#5564=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 27','Patient Shifting Boards',#5547,$,$); +#5565=IFCCLASSIFICATIONREFERENCE($,'23-25 49 11 29','Patient Transfer Mats',#5547,$,$); +#5566=IFCCLASSIFICATIONREFERENCE($,'23-25 49 13','Patient lifts',#5546,$,$); +#5567=IFCCLASSIFICATIONREFERENCE($,'23-25 49 13 11','Patient Scissor Lifts',#5566,$,$); +#5568=IFCCLASSIFICATIONREFERENCE($,'23-25 49 13 13','Clinical Hydraulic Lifts',#5566,$,$); +#5569=IFCCLASSIFICATIONREFERENCE($,'23-25 49 13 15','Patient Suspended Seats',#5566,$,$); +#5570=IFCCLASSIFICATIONREFERENCE($,'23-25 49 13 17','Patient Suspended Slings',#5566,$,$); +#5571=IFCCLASSIFICATIONREFERENCE($,'23-25 49 13 19','Patient Ceiling Hoists',#5566,$,$); +#5572=IFCCLASSIFICATIONREFERENCE($,'23-25 49 13 21','Clinical Infant Slings',#5566,$,$); +#5573=IFCCLASSIFICATIONREFERENCE($,'23-25 49 13 21 11','Patient Hoists',#5572,$,$); +#5574=IFCCLASSIFICATIONREFERENCE($,'23-25 51 00','Pediatrics Products',#4635,$,$); +#5575=IFCCLASSIFICATIONREFERENCE($,'23-25 51 11','Pediatrics Furnishings',#5574,$,$); +#5576=IFCCLASSIFICATIONREFERENCE($,'23-25 51 11 11','Pediatric Beds',#5575,$,$); +#5577=IFCCLASSIFICATIONREFERENCE($,'23-25 51 11 11 11','Pediatric Bassinets',#5576,$,$); +#5578=IFCCLASSIFICATIONREFERENCE($,'23-25 51 11 11 13','Pediatric Beds',#5576,$,$); +#5579=IFCCLASSIFICATIONREFERENCE($,'23-25 51 11 11 15','Pediatric Cribs',#5576,$,$); +#5580=IFCCLASSIFICATIONREFERENCE($,'23-25 51 11 11 17','Pediatric Examination Tables',#5576,$,$); +#5581=IFCCLASSIFICATIONREFERENCE($,'23-25 51 11 11 19','Pediatric Incubators',#5576,$,$); +#5582=IFCCLASSIFICATIONREFERENCE($,'23-25 51 11 11 21','Pediatric Infant Positioning Cradles',#5576,$,$); +#5583=IFCCLASSIFICATIONREFERENCE($,'23-25 51 11 11 23','Pediatric Infant Warmers',#5576,$,$); +#5584=IFCCLASSIFICATIONREFERENCE($,'23-25 51 13','Pediatrics Equipment',#5574,$,$); +#5585=IFCCLASSIFICATIONREFERENCE($,'23-25 51 13 11','Pediatrics Ventilators',#5584,$,$); +#5586=IFCCLASSIFICATIONREFERENCE($,'23-25 51 13 11 11','Pediatric Intensive Care Ventilators',#5585,$,$); +#5587=IFCCLASSIFICATIONREFERENCE($,'23-25 51 13 11 13','Infant Intensive Care Ventilators',#5585,$,$); +#5588=IFCCLASSIFICATIONREFERENCE($,'23-25 51 15','Pediatrics Prefabricated Structures',#5574,$,$); +#5589=IFCCLASSIFICATIONREFERENCE($,'23-25 51 15 11','Infant Prefabricated Service Columns',#5588,$,$); +#5590=IFCCLASSIFICATIONREFERENCE($,'23-25 53 00','Pharmacology Products',#4635,$,$); +#5591=IFCCLASSIFICATIONREFERENCE($,'23-25 53 11','Pharmacology Furnishings',#5590,$,$); +#5592=IFCCLASSIFICATIONREFERENCE($,'23-25 53 11 11','Pharmacy Shelving Units',#5591,$,$); +#5593=IFCCLASSIFICATIONREFERENCE($,'23-25 53 11 13','Pharmacology Cabinets',#5591,$,$); +#5594=IFCCLASSIFICATIONREFERENCE($,'23-25 53 11 13 11','Medicine Cabinets',#5593,$,$); +#5595=IFCCLASSIFICATIONREFERENCE($,'23-25 53 11 13 13','Narcotic Cabinets',#5593,$,$); +#5596=IFCCLASSIFICATIONREFERENCE($,'23-25 53 11 13 13 11','Narcotic Cabinets With Safe',#5595,$,$); +#5597=IFCCLASSIFICATIONREFERENCE($,'23-25 53 13','Pharmacology Equipment',#5590,$,$); +#5598=IFCCLASSIFICATIONREFERENCE($,'23-25 53 13 11','Pharmacology Carts',#5597,$,$); +#5599=IFCCLASSIFICATIONREFERENCE($,'23-25 53 13 11 11','Medication Carts',#5598,$,$); +#5600=IFCCLASSIFICATIONREFERENCE($,'23-25 53 13 11 13','Unit Dose Medication Carts',#5598,$,$); +#5601=IFCCLASSIFICATIONREFERENCE($,'23-25 53 13 13','Tablet Products',#5597,$,$); +#5602=IFCCLASSIFICATIONREFERENCE($,'23-25 53 13 13 11','Tablet Crushers',#5601,$,$); +#5603=IFCCLASSIFICATIONREFERENCE($,'23-25 53 13 13 13','Tablet Crusher Dispensers',#5601,$,$); +#5604=IFCCLASSIFICATIONREFERENCE($,'23-25 53 13 13 15','Tablet Cutters',#5601,$,$); +#5605=IFCCLASSIFICATIONREFERENCE($,'23-25 53 15','Pharmacology Prefabricated Structures',#5590,$,$); +#5606=IFCCLASSIFICATIONREFERENCE($,'23-25 53 15 11','Pharmacy Stations',#5605,$,$); +#5607=IFCCLASSIFICATIONREFERENCE($,'23-25 55 00','Psychiatric and Psychology Products',#4635,$,$); +#5608=IFCCLASSIFICATIONREFERENCE($,'23-25 55 11','Psychiatric and Psychology Furnishings',#5607,$,$); +#5609=IFCCLASSIFICATIONREFERENCE($,'23-25 55 11 11','Psychiatric Beds',#5608,$,$); +#5610=IFCCLASSIFICATIONREFERENCE($,'23-25 55 11 11 11','Psychiatric Patient Showers',#5609,$,$); +#5611=IFCCLASSIFICATIONREFERENCE($,'23-25 55 11 11 13','Psychiatric Platform Bed Without Visible Legs',#5609,$,$); +#5612=IFCCLASSIFICATIONREFERENCE($,'23-25 55 11 11 15','Psychiatric Platform Beds',#5609,$,$); +#5613=IFCCLASSIFICATIONREFERENCE($,'23-25 55 11 11 17','Psychiatric Platform Beds',#5609,$,$); +#5614=IFCCLASSIFICATIONREFERENCE($,'23-25 55 13','Psychiatric and Psychology Equipment',#5607,$,$); +#5615=IFCCLASSIFICATIONREFERENCE($,'23-25 55 15','Psychiatric and Psychology Prefabricated Structures',#5607,$,$); +#5616=IFCCLASSIFICATIONREFERENCE($,'23-25 57 00','Sterilization Medical Products',#4635,$,$); +#5617=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11','Sterilizer Equipment',#5616,$,$); +#5618=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 11','Chemical Sterilizers',#5617,$,$); +#5619=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 13','Dry Heat Sterilizers',#5617,$,$); +#5620=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 15','Filter Sterilizers',#5617,$,$); +#5621=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 17','Gas Sterilizers',#5617,$,$); +#5622=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 19','Glass Bead Sterilizers',#5617,$,$); +#5623=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 21','Hot Air Sterilizers',#5617,$,$); +#5624=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 23','Needle Sterilizers',#5617,$,$); +#5625=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 25','Powered Instrument Cleaning Devices',#5617,$,$); +#5626=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 27','Radiation Sterilizers',#5617,$,$); +#5627=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 29','Sanitizer Heaters',#5617,$,$); +#5628=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 31','Steam Autoclaves',#5617,$,$); +#5629=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 33','Steam Sterilizers',#5617,$,$); +#5630=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 35','Sterilization Cabinets',#5617,$,$); +#5631=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 37','Sterilization Lamps',#5617,$,$); +#5632=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 39','Sterilization Water Recovery Equipment',#5617,$,$); +#5633=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 41','Double Chamber Ultrasonic Cleaners',#5617,$,$); +#5634=IFCCLASSIFICATIONREFERENCE($,'23-25 57 11 43','Single Chamber Ultrasonic Cleaners',#5617,$,$); +#5635=IFCCLASSIFICATIONREFERENCE($,'23-25 59 00','Surgical Products',#4635,$,$); +#5636=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11','Surgical Furnishings',#5635,$,$); +#5637=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 11','Surgical Beds',#5636,$,$); +#5638=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 11 11','Surgical Bedside Rails',#5637,$,$); +#5639=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 13','Surgical Sinks',#5636,$,$); +#5640=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 13 11','Surgeon Scrub Sinks',#5639,$,$); +#5641=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 13 13','Surgeon\X2\2019\X0\s Instrument Sinks',#5639,$,$); +#5642=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 15','Surgical Tables',#5636,$,$); +#5643=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 15 11','Surgical Instrument Tables',#5642,$,$); +#5644=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 15 13','Spinal Operating Tables',#5642,$,$); +#5645=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 15 15','Surgical Operating Tables',#5642,$,$); +#5646=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 15 17','Straddle Instrument Tables',#5642,$,$); +#5647=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 15 19','Medical Dressing Instrument Tables',#5642,$,$); +#5648=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 15 21','Cesarean Section Patient Procedure Tables',#5642,$,$); +#5649=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 15 23','Delivery Room Patient Procedure Tables',#5642,$,$); +#5650=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 15 25','Surgical Instrument Tables',#5642,$,$); +#5651=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 15 27','Operating Room Patient Fracture Tables',#5642,$,$); +#5652=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 15 29','Operating Room Patient Procedure Tables',#5642,$,$); +#5653=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 15 31','Surgical Equipment Stands',#5642,$,$); +#5654=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 17','Surgical Seating',#5636,$,$); +#5655=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 17 11','Surgeon Stools',#5654,$,$); +#5656=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 17 13','Rolling Surgeons Stools',#5654,$,$); +#5657=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 17 15','Surgical Step Stools',#5654,$,$); +#5658=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 19','Surgical Cabinets',#5636,$,$); +#5659=IFCCLASSIFICATIONREFERENCE($,'23-25 59 11 19 11','Surgical Instrument Cabinets',#5658,$,$); +#5660=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13','Surgical Equipment',#5635,$,$); +#5661=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 11','Surgical Carts',#5660,$,$); +#5662=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 11 11','Sterilizable Loading Carts',#5661,$,$); +#5663=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 11 13','Surgical Case Carts',#5661,$,$); +#5664=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 11 15','Surgical Dressing Carts',#5661,$,$); +#5665=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 11 17','Operating Room Case Carts',#5661,$,$); +#5666=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13','Cardiovascular Products',#5660,$,$); +#5667=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 11','Heart And Lung Machines',#5666,$,$); +#5668=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 13','Intraaortic Balloon Pumps',#5666,$,$); +#5669=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 15','Intracardiac Suction Devices',#5666,$,$); +#5670=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 17','Perfusion Blood Parameter Monitors',#5666,$,$); +#5671=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 19','Perfusion Bubble Traps',#5666,$,$); +#5672=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 21','Perfusion Cardioplegia Sets',#5666,$,$); +#5673=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 23','Perfusion Cardiotomy Reservoirs',#5666,$,$); +#5674=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 25','Perfusion Centrifugal Equipment',#5666,$,$); +#5675=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 27','Perfusion Heaters',#5666,$,$); +#5676=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 29','Perfusion Coolers',#5666,$,$); +#5677=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 31','Perfusion Dual Heater And Cooler Units',#5666,$,$); +#5678=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 33','Perfusion Haemoconcentrators',#5666,$,$); +#5679=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 35','Perfusion Oxygen Saturation Monitors',#5666,$,$); +#5680=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 37','Perfusion Oxygenators',#5666,$,$); +#5681=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 39','Perfusion Pump Heads',#5666,$,$); +#5682=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 41','Perfusion Venous Reservoirs',#5666,$,$); +#5683=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 43','Ventricular Assist Devices',#5666,$,$); +#5684=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 45','Perfusion Pumps',#5666,$,$); +#5685=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 47','Cardiovascular Reservoirs',#5666,$,$); +#5686=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 49','Surgical Coronary Artery Blowers',#5666,$,$); +#5687=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 13 51','Surgical Coronary Artery Misters',#5666,$,$); +#5688=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15','Surgical Equipment',#5660,$,$); +#5689=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 11','Surgical Basin Stands',#5688,$,$); +#5690=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 13','Cryosurgery Equipment',#5688,$,$); +#5691=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 15','Electrocautery Equipment',#5688,$,$); +#5692=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 17','Ophthalmic Irrigation Equipment',#5688,$,$); +#5693=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 19','Ophthalmic Surgery Phacoemulsification Equipment',#5688,$,$); +#5694=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 21','Ophthalmic Surgery Extrusion Equipment',#5688,$,$); +#5695=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 23','Surgical Irrigation Pumps',#5688,$,$); +#5696=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 25','Pulsed Lavage Units With Suction',#5688,$,$); +#5697=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 27','Pulsed Lavage Units With Out Suction',#5688,$,$); +#5698=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 29','Surgical Lasers',#5688,$,$); +#5699=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 29 11','CO2 Surgical Lasers',#5698,$,$); +#5700=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 29 13','KTP Surgical Lasers',#5698,$,$); +#5701=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 31','Surgical Lithotripters',#5688,$,$); +#5702=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 31 11','Extracorporeal Lithotripters',#5701,$,$); +#5703=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 31 13','Ultrasound Lithotripters',#5701,$,$); +#5704=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 33','Surgical Microscopes',#5688,$,$); +#5705=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 35','Surgical Magnifiers',#5688,$,$); +#5706=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 37','Surgical Pneumatic Tourniquets',#5688,$,$); +#5707=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 39','Surgical Electric Tourniquets',#5688,$,$); +#5708=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 41','Surgical Aspirators',#5688,$,$); +#5709=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 41 11','General Purpose Aspirator Pressure Units',#5708,$,$); +#5710=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 41 13','Low Pressure High Volume Suction Chest and Abdomen Aspirators',#5708,$,$); +#5711=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 41 15','Low Pressure Low Volume Suction Surgical Aspirators',#5708,$,$); +#5712=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 41 17','Mobile Uterine Aspirators',#5708,$,$); +#5713=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 43','Surgical Urological Tables',#5688,$,$); +#5714=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 45','Vitreo Retinal Fragmatome Surgery Equipment',#5688,$,$); +#5715=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 47','Microsurgery Equipment',#5688,$,$); +#5716=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 49','Operating Room Medication Dispensers',#5688,$,$); +#5717=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 51','Surgical Dermatomes',#5688,$,$); +#5718=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 53','Surgical Dermabraders',#5688,$,$); +#5719=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 55','Surgical Dermameshers',#5688,$,$); +#5720=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 57','Surgical Pneumatic Saws',#5688,$,$); +#5721=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 59','Surgical Pneumatic Drills',#5688,$,$); +#5722=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 61','Surgical Power Pin Drivers',#5688,$,$); +#5723=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 63','Surgical Power Saws',#5688,$,$); +#5724=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 65','Surgical Power Drills',#5688,$,$); +#5725=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 67','Surgical Power Pin Drivers',#5688,$,$); +#5726=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 69','Surgical Reamers',#5688,$,$); +#5727=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 71','Surgical Shavers',#5688,$,$); +#5728=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 73','Electrosurgical Units',#5688,$,$); +#5729=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 73 11','Dual Output Electrosurgical Units',#5728,$,$); +#5730=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 73 13','Endoscopy Electrosurgical Units',#5728,$,$); +#5731=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 73 15','Monopolar Electrosurgical Units',#5728,$,$); +#5732=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 15 73 17','Unblended Mobile Electrosurgical Units',#5728,$,$); +#5733=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 17','Surgical Lighting Fixtures',#5660,$,$); +#5734=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 17 11','Surgical Operating Room Lighting Fixtures',#5733,$,$); +#5735=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 19','Surgical Support Products',#5660,$,$); +#5736=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 19 11','Surgical Basin Sets',#5735,$,$); +#5737=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 19 13','Surgical Bone Cement Mixing Equipment',#5735,$,$); +#5738=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 19 15','Surgical Suction Canisters',#5735,$,$); +#5739=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 19 17','Surgical Glove Drying Or Powdering Equipment',#5735,$,$); +#5740=IFCCLASSIFICATIONREFERENCE($,'23-25 59 13 19 19','Surgical Fluid Decanting Devices',#5735,$,$); +#5741=IFCCLASSIFICATIONREFERENCE($,'23-25 59 15','Surgical Prefabricated Structures',#5635,$,$); +#5742=IFCCLASSIFICATIONREFERENCE($,'23-25 59 15 11','Surgical Prefabricated Service Columns',#5741,$,$); +#5743=IFCCLASSIFICATIONREFERENCE($,'23-25 61 00','Veterinary and Animal Products',#4635,$,$); +#5744=IFCCLASSIFICATIONREFERENCE($,'23-25 61 11','Veterinary and Animal Furnishings',#5743,$,$); +#5745=IFCCLASSIFICATIONREFERENCE($,'23-25 61 11 11','Veterinary Tables',#5744,$,$); +#5746=IFCCLASSIFICATIONREFERENCE($,'23-25 61 11 11 11','Veterinary Operating Tables',#5745,$,$); +#5747=IFCCLASSIFICATIONREFERENCE($,'23-25 61 11 11 13','Postmortem Animal Dissection Tables',#5745,$,$); +#5748=IFCCLASSIFICATIONREFERENCE($,'23-25 61 11 11 15','Necropsy Tables',#5745,$,$); +#5749=IFCCLASSIFICATIONREFERENCE($,'23-25 61 11 11 17','Veterinary Surgical Tables',#5745,$,$); +#5750=IFCCLASSIFICATIONREFERENCE($,'23-25 61 11 13','Veterinary Sinks',#5744,$,$); +#5751=IFCCLASSIFICATIONREFERENCE($,'23-25 61 11 13 11','Animal Cage Washing Sinks',#5750,$,$); +#5752=IFCCLASSIFICATIONREFERENCE($,'23-25 61 11 15','Veterinary Storage Chests',#5744,$,$); +#5753=IFCCLASSIFICATIONREFERENCE($,'23-25 61 13','Veterinary and Animal Equipment',#5743,$,$); +#5754=IFCCLASSIFICATIONREFERENCE($,'23-25 61 13 11','Animal Containment Products',#5753,$,$); +#5755=IFCCLASSIFICATIONREFERENCE($,'23-25 61 13 11 10','Cage Washers',#5754,$,$); +#5756=IFCCLASSIFICATIONREFERENCE($,'23-25 61 13 11 11','Small Animal Laboratory Cages',#5754,$,$); +#5757=IFCCLASSIFICATIONREFERENCE($,'23-25 61 13 11 13','Large Animal Laboratory Cages',#5754,$,$); +#5758=IFCCLASSIFICATIONREFERENCE($,'23-25 61 13 11 15','Large Animal Mobile Kennels',#5754,$,$); +#5759=IFCCLASSIFICATIONREFERENCE($,'23-25 61 13 11 15 11','Intensive Care Large Animal Mobile Kennels',#5758,$,$); +#5760=IFCCLASSIFICATIONREFERENCE($,'23-25 61 13 11 17','Small Animal Mobile Kennels',#5754,$,$); +#5761=IFCCLASSIFICATIONREFERENCE($,'23-25 61 13 11 17 11','Intensive Care Small Animal Mobile Kennels',#5760,$,$); +#5762=IFCCLASSIFICATIONREFERENCE($,'23-25 61 13 11 19','Aquaria Equipment',#5754,$,$); +#5763=IFCCLASSIFICATIONREFERENCE($,'23-25 61 13 11 21','Animal Catching Devices',#5754,$,$); +#5764=IFCCLASSIFICATIONREFERENCE($,'23-25 61 13 11 23','Fish Aeration Systems',#5754,$,$); +#5765=IFCCLASSIFICATIONREFERENCE($,'23-25 61 15','Veterinary Equipment',#5743,$,$); +#5766=IFCCLASSIFICATIONREFERENCE($,'23-25 61 15 11','Veterinary Blood Pressure Testers',#5765,$,$); +#5767=IFCCLASSIFICATIONREFERENCE($,'23-25 61 15 13','Veterinary Kymograph Testers',#5765,$,$); +#5768=IFCCLASSIFICATIONREFERENCE($,'23-25 61 15 15','Veterinary Pyrogenic Testers',#5765,$,$); +#5769=IFCCLASSIFICATIONREFERENCE($,'23-25 61 15 17','Veterinary Stereotoxic Equipment',#5765,$,$); +#5770=IFCCLASSIFICATIONREFERENCE($,'23-25 61 15 19','Veterinary Electrocardiographs ECG',#5765,$,$); +#5771=IFCCLASSIFICATIONREFERENCE($,'23-25 61 17','Veterinary and Animal Prefabricated Structures',#5743,$,$); +#5772=IFCCLASSIFICATIONREFERENCE($,'23-25 63 00','X Ray and Imagery Products',#4635,$,$); +#5773=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11','X Ray and Imagery Furnishings',#5772,$,$); +#5774=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 11','X Ray and Imagery Sinks',#5773,$,$); +#5775=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 11 11','Film Processing Sinks',#5774,$,$); +#5776=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 11 13','Lead Lined Sinks',#5774,$,$); +#5777=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 11 13 11','Lead Lined With Decay Storage Sinks',#5776,$,$); +#5778=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 13','X Ray and Imagery Protective Barriers',#5773,$,$); +#5779=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 13 11','X Ray Protective Screens',#5778,$,$); +#5780=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 13 13','Radiofrequency Proective Screens',#5778,$,$); +#5781=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 13 15','Radiological Shielding Apron Racks',#5778,$,$); +#5782=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 13 17','Portable Radioactive Materials Containers',#5778,$,$); +#5783=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 13 19','Radiological Shielding Freestanding Screens',#5778,$,$); +#5784=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 13 21','Radiological Shielding Wall',#5778,$,$); +#5785=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 13 23','Radiological Shielding Ceiling Panels',#5778,$,$); +#5786=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 13 25','Radiological Shielding Floor Installed Panels',#5778,$,$); +#5787=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 15','X Ray and Imagery Storage Units',#5773,$,$); +#5788=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 15 11','Lead Lined Storage Cabinets',#5787,$,$); +#5789=IFCCLASSIFICATIONREFERENCE($,'23-25 63 11 15 13','Photographic Slides Storage Cabinets',#5787,$,$); +#5790=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13','X Ray and Imagery Equipment',#5772,$,$); +#5791=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 11','X Ray and Imagery Carts',#5790,$,$); +#5792=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 11 11','Radium Transport Carts',#5791,$,$); +#5793=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13','Computed Tomography CT and CAT Products',#5790,$,$); +#5794=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 11','Computed Tomography CT Complete Stationary Units',#5793,$,$); +#5795=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 13','Computed Tomography CT Mobile Units',#5793,$,$); +#5796=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 15','Computed Tomography CT Van Units',#5793,$,$); +#5797=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 17','Computed Tomography CT Consoles',#5793,$,$); +#5798=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 19','Computed Tomography CT Power Conditioners',#5793,$,$); +#5799=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 21','Computed Tomography CT Tables',#5793,$,$); +#5800=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 23','Computed Tomography CT Chairs',#5793,$,$); +#5801=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 25','Computed Tomography CAT Complete Stationary Units',#5793,$,$); +#5802=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 27','Computed Tomography CAT Mobile Units',#5793,$,$); +#5803=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 29','Computed Tomography CAT Transportable Units',#5793,$,$); +#5804=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 31','Computed Tomography CAT Van Units',#5793,$,$); +#5805=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 33','Computed Tomography CAT Consoles',#5793,$,$); +#5806=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 35','Computed Tomography CAT Power Conditioners',#5793,$,$); +#5807=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 37','Computed Tomography CAT Tables',#5793,$,$); +#5808=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 39','Computed Tomography CAT Chairs',#5793,$,$); +#5809=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 41','Computerized Tomography Phantoms',#5793,$,$); +#5810=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 41 11','Body Computerized Tomography Phantoms',#5809,$,$); +#5811=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 41 13','Head Computerized Tomography Phantoms',#5809,$,$); +#5812=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 41 15','Performance Computerized Tomography Phantoms',#5809,$,$); +#5813=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 43','Computed Tomography CT Radiotherapy Simulators',#5793,$,$); +#5814=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 13 45','Computed Tomography CAT Radiotherapy Simulators',#5793,$,$); +#5815=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 15','Magnetic Resonance Imaging Products',#5790,$,$); +#5816=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 15 11','Medical Magnetic Resonance Imaging Complete Stationary Unit Installation',#5815,$,$); +#5817=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 15 13','Medical Magnetic Resonance Imaging Mobile Units',#5815,$,$); +#5818=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 15 15','Medical Magnetic Resonance Imaging Transportable Units',#5815,$,$); +#5819=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 15 17','Medical Magnetic Resonance Imaging Van Units',#5815,$,$); +#5820=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 15 19','Medical Magnetic Resonance Imaging Monitors',#5815,$,$); +#5821=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 15 21','Medical Magnetic Resonance Imaging Scanners',#5815,$,$); +#5822=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 15 23','Medical Magnetic Resonance Imaging Tables',#5815,$,$); +#5823=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17','Ultrasound Doppler And Echo Imaging Products',#5790,$,$); +#5824=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 11','Cardiac Ultrasound Units',#5823,$,$); +#5825=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 13','Cardiac Doppler Units',#5823,$,$); +#5826=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 15','Cardiac Echo Units',#5823,$,$); +#5827=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 17','Cardioscopes',#5823,$,$); +#5828=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 19','Fetal Ultrasound Units',#5823,$,$); +#5829=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 21','Fetal Echo Units',#5823,$,$); +#5830=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 23','Gynecological Ultrasound Units',#5823,$,$); +#5831=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 25','Gynecological Echo Units',#5823,$,$); +#5832=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 27','Mammographic Ultrasound Units',#5823,$,$); +#5833=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 29','Mammographic Echo Units',#5823,$,$); +#5834=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 31','Medical Ultrasound Bone Densitometers',#5823,$,$); +#5835=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 33','Medical Ultrasound Or Doppler Or Echo Monitors',#5823,$,$); +#5836=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 35','Medical Ultrasound Or Doppler Or Echo Printers',#5823,$,$); +#5837=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 37','Medical Ultrasound Transducers',#5823,$,$); +#5838=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 39','Medical Doppler Transducers',#5823,$,$); +#5839=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 41','Medical Echo Transducers',#5823,$,$); +#5840=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 43','Medical General Use Ultrasound Units',#5823,$,$); +#5841=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 45','Medical General Use Doppler Units',#5823,$,$); +#5842=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 47','Medical General Use Pulse Echo Units',#5823,$,$); +#5843=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 49','Medical General Use Echography Units',#5823,$,$); +#5844=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 51','Thesiometers',#5823,$,$); +#5845=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 53','Vaginal Ultrasound Or Echo Probes',#5823,$,$); +#5846=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 55','Vascular Ultrasound Units',#5823,$,$); +#5847=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 17 57','Medical Ultrasound Ophthalmic Scanners',#5823,$,$); +#5848=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19','X Ray Products',#5790,$,$); +#5849=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 11','Chest X Ray Equipment',#5848,$,$); +#5850=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 13','Mammography X Ray Equipment',#5848,$,$); +#5851=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 15','Medical C Arm X Ray Units',#5848,$,$); +#5852=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 17','Medical Cine Fluoroscopy Equipment',#5848,$,$); +#5853=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 19','Medical Radiology And Fluoroscopy RF Equipment',#5848,$,$); +#5854=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 21','Medical Radioisotope Scanners',#5848,$,$); +#5855=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 23','Medical X Ray Buckys',#5848,$,$); +#5856=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 25','Medical X Ray Quality Assurance Calibration Devices',#5848,$,$); +#5857=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 27','Medical X Ray Tables',#5848,$,$); +#5858=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 29','Medical X Ray Stands',#5848,$,$); +#5859=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 31','Medical X Ray Chairs',#5848,$,$); +#5860=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 33','Medical X Ray Cabinets',#5848,$,$); +#5861=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 35','Medical X Ray Tomography Units',#5848,$,$); +#5862=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 37','Medical Diagnostic Use X Ray Units',#5848,$,$); +#5863=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 39','Medical Xeroradiography Units',#5848,$,$); +#5864=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 41','X Ray Bone Densitometers',#5848,$,$); +#5865=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 43','Medical X Ray Intensifying Screens',#5848,$,$); +#5866=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 45','Medical X Ray Water Coolers',#5848,$,$); +#5867=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 47','Medical Imaging Procedure Trays',#5848,$,$); +#5868=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 49','Medical X Ray Film Hot Spot Lights',#5848,$,$); +#5869=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 51','Medical X Ray Film Large Rack Viewing Systems',#5848,$,$); +#5870=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 53','Medical X Ray Film View Boxes',#5848,$,$); +#5871=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 55','Medical X Ray Film Illuminator Windows',#5848,$,$); +#5872=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 57','Medical X Ray Film Illuminator Screens',#5848,$,$); +#5873=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 19 59','Medical X Ray Film Stereoscopes',#5848,$,$); +#5874=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 21','Gamma Cameras Products',#5790,$,$); +#5875=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 21 11','Medical General Use Gamma Cameras',#5874,$,$); +#5876=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 21 13','Lymphatic Mapping Navigator Equipment',#5874,$,$); +#5877=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 21 15','Lymphatic Mapping Probes',#5874,$,$); +#5878=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 21 17','Lymphatic Mapping Collimators',#5874,$,$); +#5879=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 23','Gamma Radiation Therapy Products',#5790,$,$); +#5880=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 23 11','Radiosurgical Gamma Knife Collimators',#5879,$,$); +#5881=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 23 13','Radiosurgical Gamma Knife Units',#5879,$,$); +#5882=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 23 15','Radiosurgical Gamma Scintillators',#5879,$,$); +#5883=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 25','Linear Accelerator Intensity Modulated Radiation Therapy Units',#5790,$,$); +#5884=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 25 11','Medical Linear Accelerator Intensity Modulated Radiation Therapy IMRT Two Dimensional Units',#5883,$,$); +#5885=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 25 13','Medical Linear Accelerator Intensity Modulated Radiation Therapy IMRT Three Dimensional Units',#5883,$,$); +#5886=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 25 15','Medical Linear Accelerator Intensity Modulated Radiation Therapy IMRT Collimators',#5883,$,$); +#5887=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 25 17','Dual Energy Linear Accelerator',#5883,$,$); +#5888=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 27','Medical Positron Emission Tomography Units',#5790,$,$); +#5889=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 27 11','Medical Positron Emission Tomography PET Units',#5888,$,$); +#5890=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 29','Medical Single Photon Emission Computed Tomography Units',#5790,$,$); +#5891=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 29 11','Medical Single Photon Emission Computed Tomography SPECT Units',#5890,$,$); +#5892=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 31','Radiotherapy Teletherapy Products',#5790,$,$); +#5893=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 31 11','Radiotherapy Teletherapy Cobalt 60 Equipment',#5892,$,$); +#5894=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 31 13','Radiotherapy Teletherapy Linear Accelerators',#5892,$,$); +#5895=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 31 15','Radiotherapy Teletherapy Orthovoltage X Ray Machines',#5892,$,$); +#5896=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 31 17','Radiotherapy Teletherapy Superficial X Ray Machines',#5892,$,$); +#5897=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 31 19','Radiotherapy Cutters',#5892,$,$); +#5898=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 31 19 11','Radiotherapy Beam Block Cutters',#5897,$,$); +#5899=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 31 19 13','Radiotherapy Compensator Cutters',#5897,$,$); +#5900=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 33','Radiographic Fluoroscopic Units',#5790,$,$); +#5901=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 33 11','Computerized Tomography Radiographic Fluoroscopic Units',#5900,$,$); +#5902=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 33 13','Digital Angio Biplane Radiographic Fluoroscopic Units',#5900,$,$); +#5903=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 33 15','Digital Cardiac Radiographic Fluoroscopic Units',#5900,$,$); +#5904=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 33 17','Digital Chest Radiographic Fluoroscopic Units',#5900,$,$); +#5905=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 33 19','Mammographic Radiographic Fluoroscopic Units',#5900,$,$); +#5906=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 33 21','Non Tilt Table Radiographic Units',#5900,$,$); +#5907=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 33 23','Table Radiographic Fluoroscopic Units',#5900,$,$); +#5908=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 33 23 11','Remote Table Radiographic Fluoroscopic Units',#5907,$,$); +#5909=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 33 25','Urologic Radiographic Fluoroscopic Units',#5900,$,$); +#5910=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 33 25 11','Computerized Tomography Urologic Radiographic Fluoroscopic Units',#5909,$,$); +#5911=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 35','Radiation Detection Or Monitoring Products',#5790,$,$); +#5912=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 35 11','Radiation Dosimeters',#5911,$,$); +#5913=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 35 13','Radiation Badges',#5911,$,$); +#5914=IFCCLASSIFICATIONREFERENCE($,'23-25 63 13 35 15','Radiation Detectors',#5911,$,$); +#5915=IFCCLASSIFICATIONREFERENCE($,'23-25 63 15','X Ray and Imagery Prefabricated Structures',#5772,$,$); +#5916=IFCCLASSIFICATIONREFERENCE($,'23-25 63 15 11','Radiological Shielding Chambers',#5915,$,$); +#5917=IFCCLASSIFICATIONREFERENCE($,'23-25 63 15 13','Radiological Shielding Rooms',#5915,$,$); +#5918=IFCCLASSIFICATIONREFERENCE($,'23-25 63 15 15','Radiological Shielding Safes',#5915,$,$); +#5919=IFCCLASSIFICATIONREFERENCE($,'23-25 63 17','Specialized Medical Computer Equipment',#5772,$,$); +#5920=IFCCLASSIFICATIONREFERENCE($,'23-25 63 17 11','Computer Assisted Cardiology Management System',#5919,$,$); +#5921=IFCCLASSIFICATIONREFERENCE($,'23-25 63 17 13','Nuclear Medicine Clinical Computers',#5919,$,$); +#5922=IFCCLASSIFICATIONREFERENCE($,'23-25 63 17 15','DIN PACS Computer System',#5919,$,$); +#5923=IFCCLASSIFICATIONREFERENCE($,'23-25 63 17 17','Holter Monitor Analysis Computer System',#5919,$,$); +#5924=IFCCLASSIFICATIONREFERENCE($,'23-25 63 17 19','Mean Cell Volume Computers',#5919,$,$); +#5925=IFCCLASSIFICATIONREFERENCE($,'23-25 63 17 21','Radiation Therapy Treatment Planning Computers',#5919,$,$); +#5926=IFCCLASSIFICATIONREFERENCE($,'23-25 65 00','Biological Protection and Preservation Products',#4635,$,$); +#5927=IFCCLASSIFICATIONREFERENCE($,'23-25 65 11','Biological Safety Cabinets',#5926,$,$); +#5928=IFCCLASSIFICATIONREFERENCE($,'23-25 65 11 11','Biological Safety Class I Cabinets',#5927,$,$); +#5929=IFCCLASSIFICATIONREFERENCE($,'23-25 65 11 13','Biological Safety Class II Cabinets',#5927,$,$); +#5930=IFCCLASSIFICATIONREFERENCE($,'23-25 65 11 15','Biological Safety Class III Cabinets',#5927,$,$); +#5931=IFCCLASSIFICATIONREFERENCE($,'23-25 65 11 17','Cryogenic Freezers',#5927,$,$); +#5932=IFCCLASSIFICATIONREFERENCE($,'23-25 65 11 19','Biological Freezers',#5927,$,$); +#5933=IFCCLASSIFICATIONREFERENCE($,'23-25 65 11 21','Biological Refrigerators',#5927,$,$); +#5934=IFCCLASSIFICATIONREFERENCE($,'23-25 65 13','Cabinet Bases',#5926,$,$); +#5935=IFCCLASSIFICATIONREFERENCE($,'23-25 65 13 11','Biological Safety Class I Cabinet Bases',#5934,$,$); +#5936=IFCCLASSIFICATIONREFERENCE($,'23-25 65 13 13','Biological Safety Class II Cabinet Bases',#5934,$,$); +#5937=IFCCLASSIFICATIONREFERENCE($,'23-25 65 13 15','Biological Safety Class III Cabinet Bases',#5934,$,$); +#5938=IFCCLASSIFICATIONREFERENCE($,'23-25 67 00','Hazardous Materials Products',#4635,$,$); +#5939=IFCCLASSIFICATIONREFERENCE($,'23-25 67 11','Hazardous Materials Cabinets',#5938,$,$); +#5940=IFCCLASSIFICATIONREFERENCE($,'23-25 67 11 11','Acid Storage Cabinets',#5939,$,$); +#5941=IFCCLASSIFICATIONREFERENCE($,'23-25 67 11 13','Flammable Storage Cabinets',#5939,$,$); +#5942=IFCCLASSIFICATIONREFERENCE($,'23-25 67 13','Hazardous Materials Refrigerators and Freezers',#5938,$,$); +#5943=IFCCLASSIFICATIONREFERENCE($,'23-25 67 13 11','Flammable Material Storage Refrigerators',#5942,$,$); +#5944=IFCCLASSIFICATIONREFERENCE($,'23-25 67 13 13','Flammable Material Storage Freezers',#5942,$,$); +#5945=IFCCLASSIFICATIONREFERENCE($,'23-25 67 13 15','Flammable Material Storage Refrigerator Freezers',#5942,$,$); +#5946=IFCCLASSIFICATIONREFERENCE($,'23-25 67 13 17','Explosion Proof Refrigerators',#5942,$,$); +#5947=IFCCLASSIFICATIONREFERENCE($,'23-25 67 13 19','Explosion Proof Refrigerator Freezers',#5942,$,$); +#5948=IFCCLASSIFICATIONREFERENCE($,'23-25 69 00','Laboratory and Scientific Products',#4635,$,$); +#5949=IFCCLASSIFICATIONREFERENCE($,'23-25 69 11','Laboratory Furnishings',#5948,$,$); +#5950=IFCCLASSIFICATIONREFERENCE($,'23-25 69 11 11','Laboratory Tables',#5949,$,$); +#5951=IFCCLASSIFICATIONREFERENCE($,'23-25 69 11 11 11','Microscope Tables',#5950,$,$); +#5952=IFCCLASSIFICATIONREFERENCE($,'23-25 69 11 13','Laboratory Seating',#5949,$,$); +#5953=IFCCLASSIFICATIONREFERENCE($,'23-25 69 11 15','Laboratory Fume hoods',#5949,$,$); +#5954=IFCCLASSIFICATIONREFERENCE($,'23-25 69 11 15 11','Bench Fume hoods',#5953,$,$); +#5955=IFCCLASSIFICATIONREFERENCE($,'23-25 69 11 15 11 11','Horizontal Laminar Flow Bench Fume hoods',#5954,$,$); +#5956=IFCCLASSIFICATIONREFERENCE($,'23-25 69 11 15 13','Floor Standing Fume hoods',#5953,$,$); +#5957=IFCCLASSIFICATIONREFERENCE($,'23-25 69 11 15 13 11','Horizontal Laminar Flow Free Standing Fume hoods',#5956,$,$); +#5958=IFCCLASSIFICATIONREFERENCE($,'23-25 69 11 15 13 13','Explosion Proof Floor Standing Fume hoods',#5956,$,$); +#5959=IFCCLASSIFICATIONREFERENCE($,'23-25 69 11 15 13 15','Perchloric Floor Standing Fume Hoods',#5956,$,$); +#5960=IFCCLASSIFICATIONREFERENCE($,'23-25 69 11 15 15','Histopathology Staining Fume Hoods',#5953,$,$); +#5961=IFCCLASSIFICATIONREFERENCE($,'23-25 69 11 15 17','Horizontal Laminar Flow Fume Hoods',#5953,$,$); +#5962=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13','Laboratory And Scientific Equipment',#5948,$,$); +#5963=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11','Microscopes',#5962,$,$); +#5964=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 11','Acoustic Microscopes',#5963,$,$); +#5965=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 13','Binocular Microscopes',#5963,$,$); +#5966=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 13 11','Phase Contrast Binocular Microscopes',#5965,$,$); +#5967=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 13 13','Binocular Light Compound Microscopes',#5965,$,$); +#5968=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 15','Bore scope Inspection Equipment',#5963,$,$); +#5969=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 17','Combination Electron And Light Microscopes',#5963,$,$); +#5970=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 19','Dark field Microscopes',#5963,$,$); +#5971=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 21','Digital Image Varityping Microscopes',#5963,$,$); +#5972=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 23','Dissecting Light Microscopes',#5963,$,$); +#5973=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 25','Electron Microscopes',#5963,$,$); +#5974=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 27','Fluorescence Microscopes',#5963,$,$); +#5975=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 29','Fluorescent Microscopes',#5963,$,$); +#5976=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 31','Inverted Microscopes',#5963,$,$); +#5977=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 33','Ion Microscopes',#5963,$,$); +#5978=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 35','Laser Scanning Microscopes',#5963,$,$); +#5979=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 37','Metallurgical Microscopes',#5963,$,$); +#5980=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 39','Monocular Microscopes',#5963,$,$); +#5981=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 41','Operating Microscopes',#5963,$,$); +#5982=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 43','Photographic Fluorescent Microscopes',#5963,$,$); +#5983=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 45','Photographic Microscopes',#5963,$,$); +#5984=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 47','Polarizing Microscopes',#5963,$,$); +#5985=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 49','Projection Microscopes',#5963,$,$); +#5986=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 51','Scanning Electron Microscopes',#5963,$,$); +#5987=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 53','Scanning Light Microscopes',#5963,$,$); +#5988=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 55','Scanning Probe Microscopes',#5963,$,$); +#5989=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 57','Spinning Disk Microscopes',#5963,$,$); +#5990=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 59','Stereo Microscopes',#5963,$,$); +#5991=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 61','Tissue Culture Inverted Microscopes',#5963,$,$); +#5992=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 63','Transmission Electron Microscopes',#5963,$,$); +#5993=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 65','Trinocular Microscopes',#5963,$,$); +#5994=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 11 67','Wide Field Microscopes',#5963,$,$); +#5995=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 13','Optical Equipment',#5962,$,$); +#5996=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 13 11','Telescopes',#5995,$,$); +#5997=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 13 13','Binoculars',#5995,$,$); +#5998=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 13 15','Videoscopes',#5995,$,$); +#5999=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 13 17','Fiberscopes',#5995,$,$); +#6000=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15','Laboratory Disruption Equipment',#5962,$,$); +#6001=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15 11','French Pressure Cells',#6000,$,$); +#6002=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15 13','Homogenizers',#6000,$,$); +#6003=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15 15','Laboratory Blenders',#6000,$,$); +#6004=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15 17','Laboratory Crushers',#6000,$,$); +#6005=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15 19','Laboratory Disintegrators',#6000,$,$); +#6006=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15 21','Laboratory Emulsifiers',#6000,$,$); +#6007=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15 23','Laboratory Mills',#6000,$,$); +#6008=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15 25','Laboratory Presses',#6000,$,$); +#6009=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15 27','Laboratory Pulverizers',#6000,$,$); +#6010=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15 29','Laboratory Tissue Grinders',#6000,$,$); +#6011=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15 31','Liquid Measuring Cans',#6000,$,$); +#6012=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15 33','Mortars',#6000,$,$); +#6013=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 15 35','Pestles',#6000,$,$); +#6014=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 17','Laboratory Heating Drying Equipment',#5962,$,$); +#6015=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 17 11','Laboratory Dry Baths',#6014,$,$); +#6016=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 17 13','Bunsen Burner',#6014,$,$); +#6017=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 17 15','Laboratory Hotplates',#6014,$,$); +#6018=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 17 17','Laboratory Incinerators',#6014,$,$); +#6019=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 17 19','Laboratory Infrared Dryers',#6014,$,$); +#6020=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 17 21','Laboratory Spirit Burners',#6014,$,$); +#6021=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 17 23','Laboratory Temperature Cycling Chambers',#6014,$,$); +#6022=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 17 25','Laboratory Thermal Cyclers',#6014,$,$); +#6023=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 17 27','Laboratory Warming Cabinets',#6014,$,$); +#6024=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 17 29','Stirring Hotplates',#6014,$,$); +#6025=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19','Histology Equipment',#5962,$,$); +#6026=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 11','Tissue Embedding Stations',#6025,$,$); +#6027=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 13','Embedding Molds',#6025,$,$); +#6028=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 15','Embedding Capsules',#6025,$,$); +#6029=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 17','Embedding Compounds',#6025,$,$); +#6030=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 19','Histological Staining Units',#6025,$,$); +#6031=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 21','Tissue Processors',#6025,$,$); +#6032=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 21 11','Automatic Tissue Processors',#6031,$,$); +#6033=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 21 13','Electron Microscopy Tissue Processors',#6031,$,$); +#6034=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 21 15','Vacuum Tissue Processors',#6031,$,$); +#6035=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 23','Tissue Culture Units',#6025,$,$); +#6036=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 25','Ultrasonic Tissue Disintegrators',#6025,$,$); +#6037=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 27','Microtomes',#6025,$,$); +#6038=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 27 11','Tilt Rotary Microtomes',#6037,$,$); +#6039=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 27 13','Refrigerated Tilt Rotary Microtomes',#6037,$,$); +#6040=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 29','Slide Warmers',#6025,$,$); +#6041=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 31','Slide Dryers',#6025,$,$); +#6042=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 19 33','Slide Stainers',#6025,$,$); +#6043=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 21','Laboratory Cooling Equipment',#5962,$,$); +#6044=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 21 11','Liquid Nitrogen Dewars',#6043,$,$); +#6045=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 21 13','Ultra Cold Upright Cabinets',#6043,$,$); +#6046=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 21 15','Ultra Cold Freezers',#6043,$,$); +#6047=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 21 17','Ultralow Upright Cabinets',#6043,$,$); +#6048=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 21 19','Ultralow Freezers',#6043,$,$); +#6049=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 21 21','Ultra Cold Chest Freezers',#6043,$,$); +#6050=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 21 23','Ultralow Chest Freezers',#6043,$,$); +#6051=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 21 25','Liquid Nitrogen Freezers',#6043,$,$); +#6052=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 21 27','Laboratory Cold Water Circulators',#6043,$,$); +#6053=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 21 29','Chromatography Refrigerators',#6043,$,$); +#6054=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 21 31','Laboratory Plate Freezers',#6043,$,$); +#6055=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 21 33','Laboratory Cold Traps',#6043,$,$); +#6056=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23','Centrifuges',#5962,$,$); +#6057=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 11','Benchtop Centrifuges',#6056,$,$); +#6058=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 13','Centrifuge Buckets',#6056,$,$); +#6059=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 15','Centrifuge Rotors',#6056,$,$); +#6060=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 17','Cytology Centrifuges',#6056,$,$); +#6061=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 19','Floor Centrifuges',#6056,$,$); +#6062=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 21','Microcentrifuges',#6056,$,$); +#6063=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 23','Microhematocrit Centrifuges',#6056,$,$); +#6064=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 25','Refrigerated Benchtop Centrifuges',#6056,$,$); +#6065=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 27','Refrigerated Floor Centrifuges',#6056,$,$); +#6066=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 29','Refrigerated Microcentrifuges',#6056,$,$); +#6067=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 31','Serological Centrifuges',#6056,$,$); +#6068=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 31 11','Multiple Speed Serological Centrifuges',#6067,$,$); +#6069=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 33','Tabletop Centrifuges',#6056,$,$); +#6070=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 35','Ultracentrifuges',#6056,$,$); +#6071=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 23 37','Vacuum Centrifuges',#6056,$,$); +#6072=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25','Incubators',#5962,$,$); +#6073=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 11','CO2 Incubators',#6072,$,$); +#6074=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 13','Cooled Biological Oxygen Demand BOD Incubators',#6072,$,$); +#6075=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 15','Dry Wall Dual Chamber Carbon Dioxide Incubators',#6072,$,$); +#6076=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 17','Dry Wall Dual Chamber Carbon Dioxide Incubators With Humidity Control',#6072,$,$); +#6077=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 19','Dry Wall Dual Chamber Three Gas Incubators',#6072,$,$); +#6078=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 21','Dry Wall Dual Chamber Three Gas Incubators With Humidity Control',#6072,$,$); +#6079=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 23','Dry Wall Single Chamber Carbon Dioxide Incubators',#6072,$,$); +#6080=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 25','Dry Wall Single Chamber Carbon Dioxide Incubators With Humidity Control',#6072,$,$); +#6081=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 27','Dry Wall Single Chamber Three Gas Incubators',#6072,$,$); +#6082=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 29','Dry Wall Single Chamber Three Gas Incubators With Humidity Control',#6072,$,$); +#6083=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 31','Forced Air General Purpose Incubators',#6072,$,$); +#6084=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 33','Gravity Convection General Purpose Incubators',#6072,$,$); +#6085=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 35','Mechanical Convection General Purpose Incubators',#6072,$,$); +#6086=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 37','Multipurpose Incubators',#6072,$,$); +#6087=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 39','Plate Incubators',#6072,$,$); +#6088=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 41','Refrigerated Incubators',#6072,$,$); +#6089=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 43','Shaking Incubators',#6072,$,$); +#6090=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 45','Water Jacketed Dual Chamber Carbon Dioxide Incubators',#6072,$,$); +#6091=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 47','Water Jacketed Dual Chamber Carbon Dioxide Incubators With Humidity Control',#6072,$,$); +#6092=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 49','Water Jacketed Dual Chamber Three Gas Incubators',#6072,$,$); +#6093=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 51','Water Jacketed Dual Chamber Three Gas Incubators With Humidity Control',#6072,$,$); +#6094=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 53','Water Jacketed Single Chamber Carbon Dioxide Incubators',#6072,$,$); +#6095=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 55','Water Jacketed Single Chamber Carbon Dioxide Incubators With Humidity Control',#6072,$,$); +#6096=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 57','Water Jacketed Single Chamber Three Gas Incubators',#6072,$,$); +#6097=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 25 59','Water Jacketed Single Chamber Three Gas Incubators With Humidity Control',#6072,$,$); +#6098=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 27','Laboratory Ovens',#5962,$,$); +#6099=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 27 11','Laboratory Ageing Ovens',#6098,$,$); +#6100=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 27 13','Laboratory Cleanroom Ovens',#6098,$,$); +#6101=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 27 15','Laboratory Drying Cabinets',#6098,$,$); +#6102=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 27 17','Laboratory Drying Ovens',#6098,$,$); +#6103=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 27 19','Laboratory Gravity Convection Ovens',#6098,$,$); +#6104=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 27 21','Laboratory Induction Dryers',#6098,$,$); +#6105=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 27 23','Laboratory Mechanical Convection Ovens',#6098,$,$); +#6106=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 27 25','Laboratory Vacuum Ovens',#6098,$,$); +#6107=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 29','Laboratory Distillers',#5962,$,$); +#6108=IFCCLASSIFICATIONREFERENCE($,'23-25 69 13 29 11','Laboratory Water Distillers',#6107,$,$); +#6109=IFCCLASSIFICATIONREFERENCE($,'23-27 00 00','General Facility Services Products',#1606,$,$); +#6110=IFCCLASSIFICATIONREFERENCE($,'23-27 11 00','General Instruments and Controls',#6109,$,$); +#6111=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11','Temperature Measuring Instrument And Controls',#6110,$,$); +#6112=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 11','Temperature Alarm Modules',#6111,$,$); +#6113=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 13','Temperature Control Modules',#6111,$,$); +#6114=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 15','Temperature Controllers',#6111,$,$); +#6115=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 15 11','Digital Temperature Controllers',#6114,$,$); +#6116=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 15 13','Electric Temperature Controllers',#6114,$,$); +#6117=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 15 15','Pneumatic Hating Controllers',#6114,$,$); +#6118=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 15 17','Hydraulic Temperature Controllers',#6114,$,$); +#6119=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 17','Temperature Detectors',#6111,$,$); +#6120=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 17 11','Thermocouple Detectors',#6119,$,$); +#6121=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 17 13','RTD Detectors',#6119,$,$); +#6122=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 19','Temperature Indicators',#6111,$,$); +#6123=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 21','Temperature Recorders',#6111,$,$); +#6124=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 23','Temperature Sensors',#6111,$,$); +#6125=IFCCLASSIFICATIONREFERENCE($,'23-27 11 11 23 11','Thermocouple Probes',#6124,$,$); +#6126=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13','Pressure Measuring Instrument And Controls',#6110,$,$); +#6127=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 11','Pressure Alarm Modules',#6126,$,$); +#6128=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 13','Pressure Control Modules',#6126,$,$); +#6129=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 15','Pressure Controllers',#6126,$,$); +#6130=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 15 11','Digital Pressure Controllers',#6129,$,$); +#6131=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 15 13','Electric Pressure Controllers',#6129,$,$); +#6132=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 15 15','Pneumatic Hating Controllers',#6129,$,$); +#6133=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 15 17','Hydraulic Pressure Controllers',#6129,$,$); +#6134=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 17','Pressure Detectors',#6126,$,$); +#6135=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 19','Pressure Indicators',#6126,$,$); +#6136=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 21','Pressure Recorders',#6126,$,$); +#6137=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 23','Pressure Sensors',#6126,$,$); +#6138=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 25','Differential Pressure Alarm Modules',#6126,$,$); +#6139=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 27','Differential Pressure Control Modules',#6126,$,$); +#6140=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 29','Differential Pressure Controllers',#6126,$,$); +#6141=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 29 11','Digital Differential Pressure Controllers',#6140,$,$); +#6142=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 29 13','Electric Differential Pressure Controllers',#6140,$,$); +#6143=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 29 15','Pneumatic Hating Controllers',#6140,$,$); +#6144=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 29 17','Hydraulic Differential Pressure Controllers',#6140,$,$); +#6145=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 31','Differential Pressure Detectors',#6126,$,$); +#6146=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 33','Differential Pressure Indicators',#6126,$,$); +#6147=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 35','Differential Pressure Recorders',#6126,$,$); +#6148=IFCCLASSIFICATIONREFERENCE($,'23-27 11 13 37','Differential Pressure Sensors',#6126,$,$); +#6149=IFCCLASSIFICATIONREFERENCE($,'23-27 11 15','Flow Measuring Instrument And Controls',#6110,$,$); +#6150=IFCCLASSIFICATIONREFERENCE($,'23-27 11 15 11','Flow Alarm Modules',#6149,$,$); +#6151=IFCCLASSIFICATIONREFERENCE($,'23-27 11 15 13','Flow Control Modules',#6149,$,$); +#6152=IFCCLASSIFICATIONREFERENCE($,'23-27 11 15 15','Flow Controllers',#6149,$,$); +#6153=IFCCLASSIFICATIONREFERENCE($,'23-27 11 15 15 11','Digital Flow Controllers',#6152,$,$); +#6154=IFCCLASSIFICATIONREFERENCE($,'23-27 11 15 15 13','Electric Flow Controllers',#6152,$,$); +#6155=IFCCLASSIFICATIONREFERENCE($,'23-27 11 15 15 15','Pneumatic Hating Controllers',#6152,$,$); +#6156=IFCCLASSIFICATIONREFERENCE($,'23-27 11 15 15 17','Hydraulic Flow Controllers',#6152,$,$); +#6157=IFCCLASSIFICATIONREFERENCE($,'23-27 11 15 17','Flow Detectors',#6149,$,$); +#6158=IFCCLASSIFICATIONREFERENCE($,'23-27 11 15 19','Flow Indicators',#6149,$,$); +#6159=IFCCLASSIFICATIONREFERENCE($,'23-27 11 15 21','Flow Recorders',#6149,$,$); +#6160=IFCCLASSIFICATIONREFERENCE($,'23-27 11 15 23','Flow Sensors',#6149,$,$); +#6161=IFCCLASSIFICATIONREFERENCE($,'23-27 11 17','Concentration Measuring Instrument And Controls',#6110,$,$); +#6162=IFCCLASSIFICATIONREFERENCE($,'23-27 11 17 11','Humidity Concentration Measuring Instruments',#6161,$,$); +#6163=IFCCLASSIFICATIONREFERENCE($,'23-27 11 17 13','Carbon Dioxide (CO\X2\00B2\X0\) Concentration Measuring Instruments',#6161,$,$); +#6164=IFCCLASSIFICATIONREFERENCE($,'23-27 11 17 15','Ozone Concentration Measuring Instruments',#6161,$,$); +#6165=IFCCLASSIFICATIONREFERENCE($,'23-27 11 17 17','Other Gas Concentration Measuring Instruments',#6161,$,$); +#6166=IFCCLASSIFICATIONREFERENCE($,'23-27 11 19','Heat Measuring Instrument And Controls',#6110,$,$); +#6167=IFCCLASSIFICATIONREFERENCE($,'23-27 11 19 11','Heat Detectors',#6166,$,$); +#6168=IFCCLASSIFICATIONREFERENCE($,'23-27 11 19 13','Heating Controllers',#6166,$,$); +#6169=IFCCLASSIFICATIONREFERENCE($,'23-27 11 19 13 11','Digital Heating Controllers',#6168,$,$); +#6170=IFCCLASSIFICATIONREFERENCE($,'23-27 11 19 13 13','Electric Heating Controllers',#6168,$,$); +#6171=IFCCLASSIFICATIONREFERENCE($,'23-27 11 19 13 15','Pneumatic Hating Controllers',#6168,$,$); +#6172=IFCCLASSIFICATIONREFERENCE($,'23-27 11 19 13 17','Hydraulic Heating Controllers',#6168,$,$); +#6173=IFCCLASSIFICATIONREFERENCE($,'23-27 11 19 15','Heating Programmers',#6166,$,$); +#6174=IFCCLASSIFICATIONREFERENCE($,'23-27 11 19 17','Heating Optimizers',#6166,$,$); +#6175=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21','Level Measuring Instrument And Controls',#6110,$,$); +#6176=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21 11','Level Alarm Modules',#6175,$,$); +#6177=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21 13','Level Control Modules',#6175,$,$); +#6178=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21 15','Level Controllers',#6175,$,$); +#6179=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21 15 11','Digital Level Controllers',#6178,$,$); +#6180=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21 15 13','Electric Level Controllers',#6178,$,$); +#6181=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21 15 15','Pneumatic Hating Controllers',#6178,$,$); +#6182=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21 15 17','Hydraulic Level Controllers',#6178,$,$); +#6183=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21 17','Level Detectors',#6175,$,$); +#6184=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21 19','Level Indicators',#6175,$,$); +#6185=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21 19 11','Level Gage Glasses',#6184,$,$); +#6186=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21 19 13','Level Bull''s Eyes',#6184,$,$); +#6187=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21 21','Level Recorders',#6175,$,$); +#6188=IFCCLASSIFICATIONREFERENCE($,'23-27 11 21 23','Level Sensors',#6175,$,$); +#6189=IFCCLASSIFICATIONREFERENCE($,'23-27 11 23','Weighing Instrument And Controls',#6110,$,$); +#6190=IFCCLASSIFICATIONREFERENCE($,'23-27 11 23 11','Weight Alarm Modules',#6189,$,$); +#6191=IFCCLASSIFICATIONREFERENCE($,'23-27 11 23 13','Weight Control Modules',#6189,$,$); +#6192=IFCCLASSIFICATIONREFERENCE($,'23-27 11 23 15','Weight Detectors',#6189,$,$); +#6193=IFCCLASSIFICATIONREFERENCE($,'23-27 11 23 17','Weight Indicators',#6189,$,$); +#6194=IFCCLASSIFICATIONREFERENCE($,'23-27 11 23 19','Weight Recorders',#6189,$,$); +#6195=IFCCLASSIFICATIONREFERENCE($,'23-27 11 23 21','Weight Sensors',#6189,$,$); +#6196=IFCCLASSIFICATIONREFERENCE($,'23-27 11 25','Metal Concentration Instrument And Controls',#6110,$,$); +#6197=IFCCLASSIFICATIONREFERENCE($,'23-27 11 25 11','Metal Detectors',#6196,$,$); +#6198=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27','Gas Instrument And Controls',#6110,$,$); +#6199=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 11','Gas Alarm Modules',#6198,$,$); +#6200=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 13','Gas Control Modules',#6198,$,$); +#6201=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 15','Gas Controllers',#6198,$,$); +#6202=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 15 11','Digital Gas Controllers',#6201,$,$); +#6203=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 15 13','Electric Gas Controllers',#6201,$,$); +#6204=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 15 15','Pneumatic Hating Controllers',#6201,$,$); +#6205=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 15 17','Hydraulic Gas Controllers',#6201,$,$); +#6206=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 17','Gas Detectors',#6198,$,$); +#6207=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 17 11','Air Pollution Detectors',#6206,$,$); +#6208=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 17 13','Radon Detectors',#6206,$,$); +#6209=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 17 15','Carbon Dioxide Detectors',#6206,$,$); +#6210=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 17 17','Hydrogen Detectors',#6206,$,$); +#6211=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 17 19','Oxygen Detectors',#6206,$,$); +#6212=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 17 21','Halon Detectors',#6206,$,$); +#6213=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 19','Gas Indicators',#6198,$,$); +#6214=IFCCLASSIFICATIONREFERENCE($,'23-27 11 27 21','Gas Analyzers',#6198,$,$); +#6215=IFCCLASSIFICATIONREFERENCE($,'23-27 11 29','Infrared Instrument And Controls',#6110,$,$); +#6216=IFCCLASSIFICATIONREFERENCE($,'23-27 11 29 11','Photoelectric Cells',#6215,$,$); +#6217=IFCCLASSIFICATIONREFERENCE($,'23-27 11 29 13','Infrared Control Modules',#6215,$,$); +#6218=IFCCLASSIFICATIONREFERENCE($,'23-27 11 29 15','Infrared Controllers',#6215,$,$); +#6219=IFCCLASSIFICATIONREFERENCE($,'23-27 11 29 15 11','Digital Infrared Controllers',#6218,$,$); +#6220=IFCCLASSIFICATIONREFERENCE($,'23-27 11 29 15 13','Electric Infrared Controllers',#6218,$,$); +#6221=IFCCLASSIFICATIONREFERENCE($,'23-27 11 29 15 15','Pneumatic Hating Controllers',#6218,$,$); +#6222=IFCCLASSIFICATIONREFERENCE($,'23-27 11 29 15 17','Hydraulic Infrared Controllers',#6218,$,$); +#6223=IFCCLASSIFICATIONREFERENCE($,'23-27 13 00','Control and Monitoring Boards Panels',#6109,$,$); +#6224=IFCCLASSIFICATIONREFERENCE($,'23-27 13 11','Internal Climate Monitoring and Control Panel',#6223,$,$); +#6225=IFCCLASSIFICATIONREFERENCE($,'23-27 13 13','Building Control Systems',#6223,$,$); +#6226=IFCCLASSIFICATIONREFERENCE($,'23-27 13 13 11','Building Automated Control Panels',#6225,$,$); +#6227=IFCCLASSIFICATIONREFERENCE($,'23-27 13 13 13','Building Automated Systems',#6225,$,$); +#6228=IFCCLASSIFICATIONREFERENCE($,'23-27 13 13 15','Building Monitoring Control Panels',#6225,$,$); +#6229=IFCCLASSIFICATIONREFERENCE($,'23-27 13 15','Process Control Panels',#6223,$,$); +#6230=IFCCLASSIFICATIONREFERENCE($,'23-27 13 15 11','Gaseous Waste Monitoring and Control Panels',#6229,$,$); +#6231=IFCCLASSIFICATIONREFERENCE($,'23-27 15 00','Building Automation and Control',#6109,$,$); +#6232=IFCCLASSIFICATIONREFERENCE($,'23-27 15 11','Building Clock Controls',#6231,$,$); +#6233=IFCCLASSIFICATIONREFERENCE($,'23-27 15 13','Building Door Controls',#6231,$,$); +#6234=IFCCLASSIFICATIONREFERENCE($,'23-27 15 15','Elevator Monitoring and Controls',#6231,$,$); +#6235=IFCCLASSIFICATIONREFERENCE($,'23-27 15 17','Energy Monitoring and Controls',#6231,$,$); +#6236=IFCCLASSIFICATIONREFERENCE($,'23-27 15 19','Building Environmental Controls',#6231,$,$); +#6237=IFCCLASSIFICATIONREFERENCE($,'23-27 15 21','Building Lighting Controls',#6231,$,$); +#6238=IFCCLASSIFICATIONREFERENCE($,'23-27 15 21 11','Building Lighting Control Panel',#6237,$,$); +#6239=IFCCLASSIFICATIONREFERENCE($,'23-27 15 21 13','Lighting Relay Control Panel',#6237,$,$); +#6240=IFCCLASSIFICATIONREFERENCE($,'23-27 15 23','HVAC Controls',#6231,$,$); +#6241=IFCCLASSIFICATIONREFERENCE($,'23-27 15 23 11','HVAC Main Control Panels',#6240,$,$); +#6242=IFCCLASSIFICATIONREFERENCE($,'23-27 15 23 13','HVAC Local Control Panels',#6240,$,$); +#6243=IFCCLASSIFICATIONREFERENCE($,'23-27 15 23 15','HVAC Control Clocks',#6240,$,$); +#6244=IFCCLASSIFICATIONREFERENCE($,'23-27 15 25','Equipment Control Panels',#6231,$,$); +#6245=IFCCLASSIFICATIONREFERENCE($,'23-27 17 00','Pumps',#6109,$,$); +#6246=IFCCLASSIFICATIONREFERENCE($,'23-27 17 11','Axial Split Pumps',#6245,$,$); +#6247=IFCCLASSIFICATIONREFERENCE($,'23-27 17 13','Centrifugal Pumps',#6245,$,$); +#6248=IFCCLASSIFICATIONREFERENCE($,'23-27 17 15','Diaphragm Pumps',#6245,$,$); +#6249=IFCCLASSIFICATIONREFERENCE($,'23-27 17 17','Duplex Pumps',#6245,$,$); +#6250=IFCCLASSIFICATIONREFERENCE($,'23-27 17 19','Gear Pumps',#6245,$,$); +#6251=IFCCLASSIFICATIONREFERENCE($,'23-27 17 21','Liquid Ring Pumps',#6245,$,$); +#6252=IFCCLASSIFICATIONREFERENCE($,'23-27 17 23','Macerator Pumps',#6245,$,$); +#6253=IFCCLASSIFICATIONREFERENCE($,'23-27 17 23 11','Combined Macerator Pumps',#6252,$,$); +#6254=IFCCLASSIFICATIONREFERENCE($,'23-27 17 25','Progressive Cavity Pumps',#6245,$,$); +#6255=IFCCLASSIFICATIONREFERENCE($,'23-27 17 27','Ram Pumps',#6245,$,$); +#6256=IFCCLASSIFICATIONREFERENCE($,'23-27 17 29','Reciprocating Pumps',#6245,$,$); +#6257=IFCCLASSIFICATIONREFERENCE($,'23-27 17 31','Rotary Pumps',#6245,$,$); +#6258=IFCCLASSIFICATIONREFERENCE($,'23-27 17 31 11','Rotary Cam Pumps',#6257,$,$); +#6259=IFCCLASSIFICATIONREFERENCE($,'23-27 17 31 13','Rotary Lobe Pumps',#6257,$,$); +#6260=IFCCLASSIFICATIONREFERENCE($,'23-27 17 31 15','Rotary Screw Pumps',#6257,$,$); +#6261=IFCCLASSIFICATIONREFERENCE($,'23-27 17 31 17','Rotary Vane Pumps',#6257,$,$); +#6262=IFCCLASSIFICATIONREFERENCE($,'23-27 17 33','Rotating Piston Pumps',#6245,$,$); +#6263=IFCCLASSIFICATIONREFERENCE($,'23-27 17 35','Sewage Ejectors',#6245,$,$); +#6264=IFCCLASSIFICATIONREFERENCE($,'23-27 17 35 11','Submersible Sewage Ejectors',#6263,$,$); +#6265=IFCCLASSIFICATIONREFERENCE($,'23-27 17 37','Simplex Pumps',#6245,$,$); +#6266=IFCCLASSIFICATIONREFERENCE($,'23-27 17 39','Sliding Vane Pumps',#6245,$,$); +#6267=IFCCLASSIFICATIONREFERENCE($,'23-27 17 41','Turbine Pumps',#6245,$,$); +#6268=IFCCLASSIFICATIONREFERENCE($,'23-27 17 43','Worm Gear Pumps',#6245,$,$); +#6269=IFCCLASSIFICATIONREFERENCE($,'23-27 17 45','Pump Components',#6245,$,$); +#6270=IFCCLASSIFICATIONREFERENCE($,'23-27 19 00','Engines',#6109,$,$); +#6271=IFCCLASSIFICATIONREFERENCE($,'23-27 19 11','Reciprocating Engines',#6270,$,$); +#6272=IFCCLASSIFICATIONREFERENCE($,'23-27 19 13','Rotary Engines',#6270,$,$); +#6273=IFCCLASSIFICATIONREFERENCE($,'23-27 19 15','Turbine Engines',#6270,$,$); +#6274=IFCCLASSIFICATIONREFERENCE($,'23-27 21 00','Compressors',#6109,$,$); +#6275=IFCCLASSIFICATIONREFERENCE($,'23-27 21 11','Axial Flow Compressors',#6274,$,$); +#6276=IFCCLASSIFICATIONREFERENCE($,'23-27 21 13','Centrifugal Compressors',#6274,$,$); +#6277=IFCCLASSIFICATIONREFERENCE($,'23-27 21 15','Reciprocating Compressors',#6274,$,$); +#6278=IFCCLASSIFICATIONREFERENCE($,'23-27 21 15 11','Diaphragm Reciprocating Compressors',#6277,$,$); +#6279=IFCCLASSIFICATIONREFERENCE($,'23-27 21 15 13','Double Acting Reciprocating Compressors',#6277,$,$); +#6280=IFCCLASSIFICATIONREFERENCE($,'23-27 21 15 15','Single Acting Reciprocating Compressors',#6277,$,$); +#6281=IFCCLASSIFICATIONREFERENCE($,'23-27 21 17','Rotary Compressors',#6274,$,$); +#6282=IFCCLASSIFICATIONREFERENCE($,'23-27 21 17 11','Rotary Liquid Ring Compressors',#6281,$,$); +#6283=IFCCLASSIFICATIONREFERENCE($,'23-27 21 17 13','Rotary Lobe Compressors',#6281,$,$); +#6284=IFCCLASSIFICATIONREFERENCE($,'23-27 21 17 15','Rotary Screw Compressors',#6281,$,$); +#6285=IFCCLASSIFICATIONREFERENCE($,'23-27 21 17 17','Rotary Scroll Compressors',#6281,$,$); +#6286=IFCCLASSIFICATIONREFERENCE($,'23-27 21 17 19','Rotary Vane Compressors',#6281,$,$); +#6287=IFCCLASSIFICATIONREFERENCE($,'23-27 23 00','Heat Exchangers',#6109,$,$); +#6288=IFCCLASSIFICATIONREFERENCE($,'23-27 23 11','Heat Exchanger Economizers',#6287,$,$); +#6289=IFCCLASSIFICATIONREFERENCE($,'23-27 23 13','Plate and Frame Heat Exchangers',#6287,$,$); +#6290=IFCCLASSIFICATIONREFERENCE($,'23-27 23 13 11','Plate and Frame Regenerative Heat Exchangers',#6289,$,$); +#6291=IFCCLASSIFICATIONREFERENCE($,'23-27 23 15','Shell and Tube Heat Exchangers',#6287,$,$); +#6292=IFCCLASSIFICATIONREFERENCE($,'23-27 23 15 11','Shell and Tube Regenerative Heat Exchangers',#6291,$,$); +#6293=IFCCLASSIFICATIONREFERENCE($,'23-27 23 17','Tube and Fin Heat Exchangers',#6287,$,$); +#6294=IFCCLASSIFICATIONREFERENCE($,'23-27 23 19','Spiral Heat Exchangers',#6287,$,$); +#6295=IFCCLASSIFICATIONREFERENCE($,'23-27 23 19 11','Heat Exchangers for Ventilation Air',#6294,$,$); +#6296=IFCCLASSIFICATIONREFERENCE($,'23-27 23 21','Adiabatic Wheel Heat Exchangers',#6287,$,$); +#6297=IFCCLASSIFICATIONREFERENCE($,'23-27 23 23','Plate and Fin Heat Exchangers',#6287,$,$); +#6298=IFCCLASSIFICATIONREFERENCE($,'23-27 23 23 11','Straight Fin Plate and Fin Heat Exchangers',#6297,$,$); +#6299=IFCCLASSIFICATIONREFERENCE($,'23-27 23 23 13','Offset Fin Plate and Fin Heat Exchangers',#6297,$,$); +#6300=IFCCLASSIFICATIONREFERENCE($,'23-27 23 23 15','Wavy Fin Plate and Fin Heat Exchangers',#6297,$,$); +#6301=IFCCLASSIFICATIONREFERENCE($,'23-27 23 25','Fluid Heat Exchangers',#6287,$,$); +#6302=IFCCLASSIFICATIONREFERENCE($,'23-27 25 00','Heaters for Supplied Liquids',#6109,$,$); +#6303=IFCCLASSIFICATIONREFERENCE($,'23-27 25 11','Liquid Electric Heaters',#6302,$,$); +#6304=IFCCLASSIFICATIONREFERENCE($,'23-27 25 13','Liquid Gas Heaters',#6302,$,$); +#6305=IFCCLASSIFICATIONREFERENCE($,'23-27 25 15','Liquid Steam Heaters',#6302,$,$); +#6306=IFCCLASSIFICATIONREFERENCE($,'23-27 25 17','Liquid Fuel Oil Heaters',#6302,$,$); +#6307=IFCCLASSIFICATIONREFERENCE($,'23-27 25 17 11','Fuel Oil Pre Heaters',#6306,$,$); +#6308=IFCCLASSIFICATIONREFERENCE($,'23-27 27 00','Pressure Reducing Stations',#6109,$,$); +#6309=IFCCLASSIFICATIONREFERENCE($,'23-27 27 11','Multiple Stage Pressure Reducing Stations',#6308,$,$); +#6310=IFCCLASSIFICATIONREFERENCE($,'23-27 27 13','Single Stage Pressure Reducing Stations',#6308,$,$); +#6311=IFCCLASSIFICATIONREFERENCE($,'23-27 29 00','Tanks and Storage Structures',#6109,$,$); +#6312=IFCCLASSIFICATIONREFERENCE($,'23-27 29 11','Reservoirs',#6311,$,$); +#6313=IFCCLASSIFICATIONREFERENCE($,'23-27 29 13','Tank Foundations',#6311,$,$); +#6314=IFCCLASSIFICATIONREFERENCE($,'23-27 29 13 11','Tank Support Structures',#6313,$,$); +#6315=IFCCLASSIFICATIONREFERENCE($,'23-27 29 13 13','Tank Foundation Slabs',#6313,$,$); +#6316=IFCCLASSIFICATIONREFERENCE($,'23-27 29 15','Specialized Tanks',#6311,$,$); +#6317=IFCCLASSIFICATIONREFERENCE($,'23-27 29 15 11','Cryogenic Tanks',#6316,$,$); +#6318=IFCCLASSIFICATIONREFERENCE($,'23-27 29 15 13','Flash Tanks',#6316,$,$); +#6319=IFCCLASSIFICATIONREFERENCE($,'23-27 29 15 13 11','Steam Flash Tanks',#6318,$,$); +#6320=IFCCLASSIFICATIONREFERENCE($,'23-27 29 15 15','Septic Tanks',#6316,$,$); +#6321=IFCCLASSIFICATIONREFERENCE($,'23-27 29 15 17','Siphon Tanks',#6316,$,$); +#6322=IFCCLASSIFICATIONREFERENCE($,'23-27 29 17','Storage Constructions',#6311,$,$); +#6323=IFCCLASSIFICATIONREFERENCE($,'23-27 29 17 11','Water Towers',#6322,$,$); +#6324=IFCCLASSIFICATIONREFERENCE($,'23-27 29 17 13','Silos',#6322,$,$); +#6325=IFCCLASSIFICATIONREFERENCE($,'23-27 29 17 15','Storage Bunkers',#6322,$,$); +#6326=IFCCLASSIFICATIONREFERENCE($,'23-27 29 19','Tanks',#6311,$,$); +#6327=IFCCLASSIFICATIONREFERENCE($,'23-27 29 19 11','Multiple Wall Tanks',#6326,$,$); +#6328=IFCCLASSIFICATIONREFERENCE($,'23-27 29 19 11 11','Multiple Walled Pressure Tanks',#6327,$,$); +#6329=IFCCLASSIFICATIONREFERENCE($,'23-27 29 19 11 13','Multiple Walled Vacuum Tanks',#6327,$,$); +#6330=IFCCLASSIFICATIONREFERENCE($,'23-27 29 19 11 15','Multiple Walled Vented Tanks',#6327,$,$); +#6331=IFCCLASSIFICATIONREFERENCE($,'23-27 29 19 13','Single Walled Tanks',#6326,$,$); +#6332=IFCCLASSIFICATIONREFERENCE($,'23-27 29 19 13 11','Single Walled Pressure Tanks',#6331,$,$); +#6333=IFCCLASSIFICATIONREFERENCE($,'23-27 29 19 13 13','Single Walled Vacuum Tanks',#6331,$,$); +#6334=IFCCLASSIFICATIONREFERENCE($,'23-27 29 19 13 15','Single Walled Vented Tanks',#6331,$,$); +#6335=IFCCLASSIFICATIONREFERENCE($,'23-27 29 21','Tank Containments',#6311,$,$); +#6336=IFCCLASSIFICATIONREFERENCE($,'23-27 29 21 11','Aboveground Tank Containments',#6335,$,$); +#6337=IFCCLASSIFICATIONREFERENCE($,'23-27 29 21 11 11','Aboveground Primary Tank Containments',#6336,$,$); +#6338=IFCCLASSIFICATIONREFERENCE($,'23-27 29 21 11 13','Aboveground Secondary Tank Containments',#6336,$,$); +#6339=IFCCLASSIFICATIONREFERENCE($,'23-27 29 21 11 15','Aboveground Tertiary Tank Containments',#6336,$,$); +#6340=IFCCLASSIFICATIONREFERENCE($,'23-27 29 21 13','Underground Tank Containments',#6335,$,$); +#6341=IFCCLASSIFICATIONREFERENCE($,'23-27 29 21 13 11','Underground Primary Tank Containments',#6340,$,$); +#6342=IFCCLASSIFICATIONREFERENCE($,'23-27 29 21 13 13','Underground Secondary Tank Containments',#6340,$,$); +#6343=IFCCLASSIFICATIONREFERENCE($,'23-27 29 21 13 15','Underground Tertiary Tank Containments',#6340,$,$); +#6344=IFCCLASSIFICATIONREFERENCE($,'23-27 29 23','Tank Linings',#6311,$,$); +#6345=IFCCLASSIFICATIONREFERENCE($,'23-27 29 23 11','Tank Bladders',#6344,$,$); +#6346=IFCCLASSIFICATIONREFERENCE($,'23-27 29 23 13','Rubber Tank Linings',#6344,$,$); +#6347=IFCCLASSIFICATIONREFERENCE($,'23-27 29 25','Tank Components',#6311,$,$); +#6348=IFCCLASSIFICATIONREFERENCE($,'23-27 29 25 11','Overflow Regulators',#6347,$,$); +#6349=IFCCLASSIFICATIONREFERENCE($,'23-27 29 25 13','Fill and Valve Caps',#6347,$,$); +#6350=IFCCLASSIFICATIONREFERENCE($,'23-27 29 25 15','Tank Vents',#6347,$,$); +#6351=IFCCLASSIFICATIONREFERENCE($,'23-27 31 00','Valves',#6109,$,$); +#6352=IFCCLASSIFICATIONREFERENCE($,'23-27 31 11','Backflow Preventors',#6351,$,$); +#6353=IFCCLASSIFICATIONREFERENCE($,'23-27 31 13','Balancing Valves',#6351,$,$); +#6354=IFCCLASSIFICATIONREFERENCE($,'23-27 31 13 11','Gate Balancing Valves',#6353,$,$); +#6355=IFCCLASSIFICATIONREFERENCE($,'23-27 31 13 13','Butterfly Balancing Valves',#6353,$,$); +#6356=IFCCLASSIFICATIONREFERENCE($,'23-27 31 13 15','Plug Balancing Valves',#6353,$,$); +#6357=IFCCLASSIFICATIONREFERENCE($,'23-27 31 13 17','Globe Balancing Valves',#6353,$,$); +#6358=IFCCLASSIFICATIONREFERENCE($,'23-27 31 13 19','Check Balancing Valves',#6353,$,$); +#6359=IFCCLASSIFICATIONREFERENCE($,'23-27 31 13 21','Diaphragm Balancing Valves',#6353,$,$); +#6360=IFCCLASSIFICATIONREFERENCE($,'23-27 31 15','Ball Valves',#6351,$,$); +#6361=IFCCLASSIFICATIONREFERENCE($,'23-27 31 17','Butterfly Valves',#6351,$,$); +#6362=IFCCLASSIFICATIONREFERENCE($,'23-27 31 17 11','Lug Pattern Butterfly Valves',#6361,$,$); +#6363=IFCCLASSIFICATIONREFERENCE($,'23-27 31 17 13','Wafer Pattern Butterfly Valves',#6361,$,$); +#6364=IFCCLASSIFICATIONREFERENCE($,'23-27 31 19','Check Valves',#6351,$,$); +#6365=IFCCLASSIFICATIONREFERENCE($,'23-27 31 19 11','Ball Check Valves',#6364,$,$); +#6366=IFCCLASSIFICATIONREFERENCE($,'23-27 31 19 13','Clapper CheckValves',#6364,$,$); +#6367=IFCCLASSIFICATIONREFERENCE($,'23-27 31 19 15','Cone Type Check Valves',#6364,$,$); +#6368=IFCCLASSIFICATIONREFERENCE($,'23-27 31 19 17','Demand Check Valves',#6364,$,$); +#6369=IFCCLASSIFICATIONREFERENCE($,'23-27 31 19 19','Diaphragm Check Valves',#6364,$,$); +#6370=IFCCLASSIFICATIONREFERENCE($,'23-27 31 19 21','Lift Check Valves',#6364,$,$); +#6371=IFCCLASSIFICATIONREFERENCE($,'23-27 31 19 23','Spring Type Check Valves',#6364,$,$); +#6372=IFCCLASSIFICATIONREFERENCE($,'23-27 31 19 25','Stop Check Valves',#6364,$,$); +#6373=IFCCLASSIFICATIONREFERENCE($,'23-27 31 19 27','Swing Check Valves',#6364,$,$); +#6374=IFCCLASSIFICATIONREFERENCE($,'23-27 31 21','Diaphragm Valves',#6351,$,$); +#6375=IFCCLASSIFICATIONREFERENCE($,'23-27 31 23','Float Valves',#6351,$,$); +#6376=IFCCLASSIFICATIONREFERENCE($,'23-27 31 25','Gate Valves',#6351,$,$); +#6377=IFCCLASSIFICATIONREFERENCE($,'23-27 31 27','Globe Valves',#6351,$,$); +#6378=IFCCLASSIFICATIONREFERENCE($,'23-27 31 29','Mixing Valves',#6351,$,$); +#6379=IFCCLASSIFICATIONREFERENCE($,'23-27 31 29 11','Manual Mixing Valves',#6378,$,$); +#6380=IFCCLASSIFICATIONREFERENCE($,'23-27 31 29 13','Pressure Balanced Controlled Mixing Valves',#6378,$,$); +#6381=IFCCLASSIFICATIONREFERENCE($,'23-27 31 29 15','Thermostatically Controlled Mixing Valves',#6378,$,$); +#6382=IFCCLASSIFICATIONREFERENCE($,'23-27 31 31','Needle Valves',#6351,$,$); +#6383=IFCCLASSIFICATIONREFERENCE($,'23-27 31 33','Orifice Valves',#6351,$,$); +#6384=IFCCLASSIFICATIONREFERENCE($,'23-27 31 35','Pinch Valves',#6351,$,$); +#6385=IFCCLASSIFICATIONREFERENCE($,'23-27 31 37','Plug Drain Valves',#6351,$,$); +#6386=IFCCLASSIFICATIONREFERENCE($,'23-27 31 39','Plug Valves',#6351,$,$); +#6387=IFCCLASSIFICATIONREFERENCE($,'23-27 31 41','Poppet Valves',#6351,$,$); +#6388=IFCCLASSIFICATIONREFERENCE($,'23-27 31 43','Post Indicator Valves',#6351,$,$); +#6389=IFCCLASSIFICATIONREFERENCE($,'23-27 31 45','Preaction Valves',#6351,$,$); +#6390=IFCCLASSIFICATIONREFERENCE($,'23-27 31 45 11','Electronic Actuated Preaction Valves',#6389,$,$); +#6391=IFCCLASSIFICATIONREFERENCE($,'23-27 31 45 13','Water Seal Enabled Preaction Valves',#6389,$,$); +#6392=IFCCLASSIFICATIONREFERENCE($,'23-27 31 47','Pressure Regulating Valves',#6351,$,$); +#6393=IFCCLASSIFICATIONREFERENCE($,'23-27 31 49','Relief Valves',#6351,$,$); +#6394=IFCCLASSIFICATIONREFERENCE($,'23-27 31 49 11','Pressure Relief Valves',#6393,$,$); +#6395=IFCCLASSIFICATIONREFERENCE($,'23-27 31 49 13','Pressure Temperature Relief Valves',#6393,$,$); +#6396=IFCCLASSIFICATIONREFERENCE($,'23-27 31 51','Rupture Disks',#6351,$,$); +#6397=IFCCLASSIFICATIONREFERENCE($,'23-27 31 53','Safety Valves',#6351,$,$); +#6398=IFCCLASSIFICATIONREFERENCE($,'23-27 31 53 11','Pressure Safety Valves',#6397,$,$); +#6399=IFCCLASSIFICATIONREFERENCE($,'23-27 31 53 13','Pressure Temperature Safety Valves',#6397,$,$); +#6400=IFCCLASSIFICATIONREFERENCE($,'23-27 31 55','Sentinel Valves',#6351,$,$); +#6401=IFCCLASSIFICATIONREFERENCE($,'23-27 31 57','Slider Valves',#6351,$,$); +#6402=IFCCLASSIFICATIONREFERENCE($,'23-27 31 59','Slush Valves',#6351,$,$); +#6403=IFCCLASSIFICATIONREFERENCE($,'23-27 31 61','Thermostatic Expansion Valves',#6351,$,$); +#6404=IFCCLASSIFICATIONREFERENCE($,'23-27 31 63','Valves Boxes',#6351,$,$); +#6405=IFCCLASSIFICATIONREFERENCE($,'23-27 33 00','Valve Actuators',#6109,$,$); +#6406=IFCCLASSIFICATIONREFERENCE($,'23-27 33 11','Electrical Valve Actuators',#6405,$,$); +#6407=IFCCLASSIFICATIONREFERENCE($,'23-27 33 11 11','Solenoid Valve Actuators',#6406,$,$); +#6408=IFCCLASSIFICATIONREFERENCE($,'23-27 33 13','Hydraulic Valve Actuators',#6405,$,$); +#6409=IFCCLASSIFICATIONREFERENCE($,'23-27 33 15','Motor Operated Valve Actuators',#6405,$,$); +#6410=IFCCLASSIFICATIONREFERENCE($,'23-27 33 17','Pneumatic Valve Actuators',#6405,$,$); +#6411=IFCCLASSIFICATIONREFERENCE($,'23-27 35 00','Variable Speed Drives',#6109,$,$); +#6412=IFCCLASSIFICATIONREFERENCE($,'23-27 35 11','Hydraulic Variable Speed Drives',#6411,$,$); +#6413=IFCCLASSIFICATIONREFERENCE($,'23-27 35 11 11','Hydrodynamic Variable Speed Drives',#6412,$,$); +#6414=IFCCLASSIFICATIONREFERENCE($,'23-27 35 11 13','Hydrostatic Variable Speed Drives',#6412,$,$); +#6415=IFCCLASSIFICATIONREFERENCE($,'23-27 35 11 15','Hydroviscous Variable Speed Drives',#6412,$,$); +#6416=IFCCLASSIFICATIONREFERENCE($,'23-27 35 13','Variable Pitch Drives',#6411,$,$); +#6417=IFCCLASSIFICATIONREFERENCE($,'23-27 35 13 11','Pulley Variable Pitch Drives',#6416,$,$); +#6418=IFCCLASSIFICATIONREFERENCE($,'23-27 35 13 13','Traction Variable Pitch Drives',#6416,$,$); +#6419=IFCCLASSIFICATIONREFERENCE($,'23-27 35 15','Transmission Devices',#6411,$,$); +#6420=IFCCLASSIFICATIONREFERENCE($,'23-27 35 15 11','Fluid Drive Transmissions',#6419,$,$); +#6421=IFCCLASSIFICATIONREFERENCE($,'23-27 35 15 13','Gear Boxes',#6419,$,$); +#6422=IFCCLASSIFICATIONREFERENCE($,'23-27 37 00','Liquid Traps',#6109,$,$); +#6423=IFCCLASSIFICATIONREFERENCE($,'23-27 37 11','Grease Traps',#6422,$,$); +#6424=IFCCLASSIFICATIONREFERENCE($,'23-27 37 13','Oil Traps',#6422,$,$); +#6425=IFCCLASSIFICATIONREFERENCE($,'23-27 37 15','Steam Traps',#6422,$,$); +#6426=IFCCLASSIFICATIONREFERENCE($,'23-27 37 15 11','Disc Steam Traps',#6425,$,$); +#6427=IFCCLASSIFICATIONREFERENCE($,'23-27 37 15 13','Float and Thermostatic Steam Traps',#6425,$,$); +#6428=IFCCLASSIFICATIONREFERENCE($,'23-27 37 15 15','Float Steam Trap',#6425,$,$); +#6429=IFCCLASSIFICATIONREFERENCE($,'23-27 37 15 17','Inverted Basket Steam Traps',#6425,$,$); +#6430=IFCCLASSIFICATIONREFERENCE($,'23-27 37 15 19','Orifice Steam Traps',#6425,$,$); +#6431=IFCCLASSIFICATIONREFERENCE($,'23-27 39 00','Piping',#6109,$,$); +#6432=IFCCLASSIFICATIONREFERENCE($,'23-27 39 11','Double Walled Pipes',#6431,$,$); +#6433=IFCCLASSIFICATIONREFERENCE($,'23-27 39 11 11','Aboveground Double Walled Pipes',#6432,$,$); +#6434=IFCCLASSIFICATIONREFERENCE($,'23-27 39 11 13','Underground Double Walled Pipes',#6432,$,$); +#6435=IFCCLASSIFICATIONREFERENCE($,'23-27 39 13','Single Walled Pipes',#6431,$,$); +#6436=IFCCLASSIFICATIONREFERENCE($,'23-27 39 13 11','Aboveground Single Walled Pipes',#6435,$,$); +#6437=IFCCLASSIFICATIONREFERENCE($,'23-27 39 13 13','Underground Single Walled Pipes',#6435,$,$); +#6438=IFCCLASSIFICATIONREFERENCE($,'23-27 41 00','Pipe Repair Equipment',#6109,$,$); +#6439=IFCCLASSIFICATIONREFERENCE($,'23-27 41 11','Pipe Band It Kits',#6438,$,$); +#6440=IFCCLASSIFICATIONREFERENCE($,'23-27 43 00','Pipe Fittings',#6109,$,$); +#6441=IFCCLASSIFICATIONREFERENCE($,'23-27 43 11','Mechanical Pipe Fasteners',#6440,$,$); +#6442=IFCCLASSIFICATIONREFERENCE($,'23-27 43 13','Mechanical Pipe Supports',#6440,$,$); +#6443=IFCCLASSIFICATIONREFERENCE($,'23-27 43 15','Pipe Expansion Joints',#6440,$,$); +#6444=IFCCLASSIFICATIONREFERENCE($,'23-27 43 17','Water Hammer Arrestors',#6440,$,$); +#6445=IFCCLASSIFICATIONREFERENCE($,'23-27 43 19','Pipe Expansion Compensators',#6440,$,$); +#6446=IFCCLASSIFICATIONREFERENCE($,'23-27 45 00','Pipe Flanges',#6109,$,$); +#6447=IFCCLASSIFICATIONREFERENCE($,'23-27 45 11','Blind Pipe Flanges',#6446,$,$); +#6448=IFCCLASSIFICATIONREFERENCE($,'23-27 45 13','Lap Joint Pipe Flanges',#6446,$,$); +#6449=IFCCLASSIFICATIONREFERENCE($,'23-27 45 15','Orifice Pipe Flanges',#6446,$,$); +#6450=IFCCLASSIFICATIONREFERENCE($,'23-27 45 17','Plate Pipe Flanges',#6446,$,$); +#6451=IFCCLASSIFICATIONREFERENCE($,'23-27 45 19','Reducing Pipe Flanges',#6446,$,$); +#6452=IFCCLASSIFICATIONREFERENCE($,'23-27 45 21','Slip On Pipe Flanges',#6446,$,$); +#6453=IFCCLASSIFICATIONREFERENCE($,'23-27 45 23','Socket Weld Pipe Flanges',#6446,$,$); +#6454=IFCCLASSIFICATIONREFERENCE($,'23-27 45 25','Spectacle Pipe Flanges',#6446,$,$); +#6455=IFCCLASSIFICATIONREFERENCE($,'23-27 45 27','Threaded Pipe Flanges',#6446,$,$); +#6456=IFCCLASSIFICATIONREFERENCE($,'23-27 45 29','Weldneck Pipe Flanges',#6446,$,$); +#6457=IFCCLASSIFICATIONREFERENCE($,'23-27 47 00','Pipe Adapters',#6109,$,$); +#6458=IFCCLASSIFICATIONREFERENCE($,'23-27 47 11','Female Pipe Adapters',#6457,$,$); +#6459=IFCCLASSIFICATIONREFERENCE($,'23-27 47 13','Male Pipe Adapters',#6457,$,$); +#6460=IFCCLASSIFICATIONREFERENCE($,'23-27 47 15','Terminal Pipe Adapters',#6457,$,$); +#6461=IFCCLASSIFICATIONREFERENCE($,'23-27 47 17','Hi Low Converter Pipe Adapters',#6457,$,$); +#6462=IFCCLASSIFICATIONREFERENCE($,'23-27 47 19','Twist To Lock Y Cord Pipe Adapters',#6457,$,$); +#6463=IFCCLASSIFICATIONREFERENCE($,'23-27 47 21','Auto Converter Pipe Adapters',#6457,$,$); +#6464=IFCCLASSIFICATIONREFERENCE($,'23-27 47 23','Conduit Box Pipe Adapters',#6457,$,$); +#6465=IFCCLASSIFICATIONREFERENCE($,'23-27 47 25','Reduce Drive Pipe Adapters',#6457,$,$); +#6466=IFCCLASSIFICATIONREFERENCE($,'23-27 47 27','Red Pipe Adapters',#6457,$,$); +#6467=IFCCLASSIFICATIONREFERENCE($,'23-27 49 00','Pipe Couplings',#6109,$,$); +#6468=IFCCLASSIFICATIONREFERENCE($,'23-27 49 11','Rigid Pipe Couplings',#6467,$,$); +#6469=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13','Flexible Pipe Couplings',#6467,$,$); +#6470=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 11','Coil Spring Pipe Couplings',#6469,$,$); +#6471=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 13','Double Loop Pipe Couplings',#6469,$,$); +#6472=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 15','Tire Pipe Couplings',#6469,$,$); +#6473=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 17','Flexible Link Pipe Couplings',#6469,$,$); +#6474=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 19','Multi Jaw Pipe Couplings',#6469,$,$); +#6475=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 21','Helical Flex Pipe Couplings',#6469,$,$); +#6476=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 23','Magnetic Pipe Couplings',#6469,$,$); +#6477=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 25','Metal Bellows Pipe Couplings',#6469,$,$); +#6478=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 27','Diaphragm Pipe Couplings',#6469,$,$); +#6479=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 29','Roller Chain Pipe Couplings',#6469,$,$); +#6480=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 31','Schmidt Pipe Couplings',#6469,$,$); +#6481=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 33','Shear Pipe Couplings',#6469,$,$); +#6482=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 35','Sliding Block Pipe Couplings',#6469,$,$); +#6483=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 37','Steel Grid Pipe Couplings',#6469,$,$); +#6484=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 39','Spider Pipe Couplings',#6469,$,$); +#6485=IFCCLASSIFICATIONREFERENCE($,'23-27 49 13 41','Flexible Disc Pipe Couplings',#6469,$,$); +#6486=IFCCLASSIFICATIONREFERENCE($,'23-27 51 00','Pipe Elbows',#6109,$,$); +#6487=IFCCLASSIFICATIONREFERENCE($,'23-27 51 11','45 Degree Pipe Elbows',#6486,$,$); +#6488=IFCCLASSIFICATIONREFERENCE($,'23-27 51 13','90 Degree Pipe Elbows',#6486,$,$); +#6489=IFCCLASSIFICATIONREFERENCE($,'23-27 51 15','Reducing Pipe Elbows',#6486,$,$); +#6490=IFCCLASSIFICATIONREFERENCE($,'23-27 53 00','Pipe Caps',#6109,$,$); +#6491=IFCCLASSIFICATIONREFERENCE($,'23-27 53 11','Threaded Pipe Caps',#6490,$,$); +#6492=IFCCLASSIFICATIONREFERENCE($,'23-27 53 13','Tapered Pipe Caps',#6490,$,$); +#6493=IFCCLASSIFICATIONREFERENCE($,'23-27 53 15','Anti-roll Pipe Caps',#6490,$,$); +#6494=IFCCLASSIFICATIONREFERENCE($,'23-27 53 17','Knurled Pipe Caps',#6490,$,$); +#6495=IFCCLASSIFICATIONREFERENCE($,'23-27 53 19','Slotted Head Pipe Caps',#6490,$,$); +#6496=IFCCLASSIFICATIONREFERENCE($,'23-27 53 21','Retaining Ring Pipe Caps',#6490,$,$); +#6497=IFCCLASSIFICATIONREFERENCE($,'23-27 53 23','Tear Tab Pipe Caps',#6490,$,$); +#6498=IFCCLASSIFICATIONREFERENCE($,'23-27 53 25','Hanger Tip Pipe Caps',#6490,$,$); +#6499=IFCCLASSIFICATIONREFERENCE($,'23-27 53 27','Pull Tab Pipe Caps',#6490,$,$); +#6500=IFCCLASSIFICATIONREFERENCE($,'23-27 53 29','Vented Pipe Caps',#6490,$,$); +#6501=IFCCLASSIFICATIONREFERENCE($,'23-27 55 00','Liquid Treatment Components',#6109,$,$); +#6502=IFCCLASSIFICATIONREFERENCE($,'23-27 55 11','Liquid Filters',#6501,$,$); +#6503=IFCCLASSIFICATIONREFERENCE($,'23-27 55 11 11','Water Filters',#6502,$,$); +#6504=IFCCLASSIFICATIONREFERENCE($,'23-27 55 13','Liquid Sterilizers',#6501,$,$); +#6505=IFCCLASSIFICATIONREFERENCE($,'23-27 55 15','Liquid Salinators',#6501,$,$); +#6506=IFCCLASSIFICATIONREFERENCE($,'23-27 55 17','Liquid Chlorinators',#6501,$,$); +#6507=IFCCLASSIFICATIONREFERENCE($,'23-27 55 19','Liquid Ionizers',#6501,$,$); +#6508=IFCCLASSIFICATIONREFERENCE($,'23-27 55 21','Liquid Deionizers',#6501,$,$); +#6509=IFCCLASSIFICATIONREFERENCE($,'23-27 55 23','Liquid Deaerators',#6501,$,$); +#6510=IFCCLASSIFICATIONREFERENCE($,'23-27 55 23 11','Centrifugal Liquid Deaerators',#6509,$,$); +#6511=IFCCLASSIFICATIONREFERENCE($,'23-27 55 23 13','Spray Type Liquid Deaerators',#6509,$,$); +#6512=IFCCLASSIFICATIONREFERENCE($,'23-27 55 23 15','Tray Type Liquid Deaerators',#6509,$,$); +#6513=IFCCLASSIFICATIONREFERENCE($,'23-27 55 25','Liquid Disinfecting Ultraviolet Lighting',#6501,$,$); +#6514=IFCCLASSIFICATIONREFERENCE($,'23-27 55 27','Liquid Softeners',#6501,$,$); +#6515=IFCCLASSIFICATIONREFERENCE($,'23-27 55 27 11','Water Softeners',#6514,$,$); +#6516=IFCCLASSIFICATIONREFERENCE($,'23-27 55 29','Liquid Strainers',#6501,$,$); +#6517=IFCCLASSIFICATIONREFERENCE($,'23-27 55 29 11','Basket Strainers',#6516,$,$); +#6518=IFCCLASSIFICATIONREFERENCE($,'23-27 55 29 13','Conical Strainers',#6516,$,$); +#6519=IFCCLASSIFICATIONREFERENCE($,'23-27 55 29 15','Tee Strainers',#6516,$,$); +#6520=IFCCLASSIFICATIONREFERENCE($,'23-27 55 29 17','Y Strainers',#6516,$,$); +#6521=IFCCLASSIFICATIONREFERENCE($,'23-27 55 29 19','Reverse Osmosis Units',#6516,$,$); +#6522=IFCCLASSIFICATIONREFERENCE($,'23-27 55 29 21','Solid Separators',#6516,$,$); +#6523=IFCCLASSIFICATIONREFERENCE($,'23-27 55 31','Liquid Chemical Feeders',#6501,$,$); +#6524=IFCCLASSIFICATIONREFERENCE($,'23-27 55 31 11','Liquid Chemical Feeders',#6523,$,$); +#6525=IFCCLASSIFICATIONREFERENCE($,'23-27 55 31 13','Solid Chemical Feeders',#6523,$,$); +#6526=IFCCLASSIFICATIONREFERENCE($,'23-27 55 31 15','Gas Chemical Feeders',#6523,$,$); +#6527=IFCCLASSIFICATIONREFERENCE($,'23-27 55 33','Liquid Treatment Package Units',#6501,$,$); +#6528=IFCCLASSIFICATIONREFERENCE($,'23-27 55 33 11','Water Treatment Package Units',#6527,$,$); +#6529=IFCCLASSIFICATIONREFERENCE($,'23-27 55 35','Liquid Separators',#6501,$,$); +#6530=IFCCLASSIFICATIONREFERENCE($,'23-27 55 35 11','Centrifuge Liquid Separators',#6529,$,$); +#6531=IFCCLASSIFICATIONREFERENCE($,'23-27 55 35 13','Demister Pad Liquid Separators',#6529,$,$); +#6532=IFCCLASSIFICATIONREFERENCE($,'23-27 55 35 15','Electrical Cyclone Liquid Separators',#6529,$,$); +#6533=IFCCLASSIFICATIONREFERENCE($,'23-27 55 35 17','Hydro Cyclone Liquid Separators',#6529,$,$); +#6534=IFCCLASSIFICATIONREFERENCE($,'23-27 55 35 19','Mechanical Liquid Separators',#6529,$,$); +#6535=IFCCLASSIFICATIONREFERENCE($,'23-27 55 35 21','Mist Eliminator Liquid Separators',#6529,$,$); +#6536=IFCCLASSIFICATIONREFERENCE($,'23-27 55 35 23','Tangential Liquid Separators',#6529,$,$); +#6537=IFCCLASSIFICATIONREFERENCE($,'23-27 55 35 25','Magnetic Electronic Water Treatment',#6529,$,$); +#6538=IFCCLASSIFICATIONREFERENCE($,'23-27 55 35 27','Oil Water Curtain Separators',#6529,$,$); +#6539=IFCCLASSIFICATIONREFERENCE($,'23-27 57 00','Gas Treatment Components',#6109,$,$); +#6540=IFCCLASSIFICATIONREFERENCE($,'23-27 57 11','Vapor Traps',#6539,$,$); +#6541=IFCCLASSIFICATIONREFERENCE($,'23-27 57 13','Extractors',#6539,$,$); +#6542=IFCCLASSIFICATIONREFERENCE($,'23-27 57 13 11','Extractors for Process Air',#6541,$,$); +#6543=IFCCLASSIFICATIONREFERENCE($,'23-27 57 15','Air Injectors',#6539,$,$); +#6544=IFCCLASSIFICATIONREFERENCE($,'23-27 57 17','Air Ejectors',#6539,$,$); +#6545=IFCCLASSIFICATIONREFERENCE($,'23-27 57 19','Air Scrubbers',#6539,$,$); +#6546=IFCCLASSIFICATIONREFERENCE($,'23-27 57 19 11','Dual Throat Air Scrubbers',#6545,$,$); +#6547=IFCCLASSIFICATIONREFERENCE($,'23-27 57 19 13','Multiple Venture Air Scrubbers',#6545,$,$); +#6548=IFCCLASSIFICATIONREFERENCE($,'23-27 57 19 15','Packed Bed Air Scrubbers',#6545,$,$); +#6549=IFCCLASSIFICATIONREFERENCE($,'23-27 57 21','Supply Gas Treatment',#6539,$,$); +#6550=IFCCLASSIFICATIONREFERENCE($,'23-27 57 21 11','Steam Treatment',#6549,$,$); +#6551=IFCCLASSIFICATIONREFERENCE($,'23-27 57 21 13','Fuel Gas Treatment',#6549,$,$); +#6552=IFCCLASSIFICATIONREFERENCE($,'23-27 57 21 13 11','Gas Filters',#6551,$,$); +#6553=IFCCLASSIFICATIONREFERENCE($,'23-27 57 23','Electronic Air Purifiers',#6539,$,$); +#6554=IFCCLASSIFICATIONREFERENCE($,'23-27 57 25','Mechanically Aided Air Scrubbers',#6539,$,$); +#6555=IFCCLASSIFICATIONREFERENCE($,'23-27 57 27','Air Filters',#6539,$,$); +#6556=IFCCLASSIFICATIONREFERENCE($,'23-27 57 27 11','Air Filter Components',#6555,$,$); +#6557=IFCCLASSIFICATIONREFERENCE($,'23-27 57 27 11 11','Air Filter Media',#6556,$,$); +#6558=IFCCLASSIFICATIONREFERENCE($,'23-27 57 27 11 13','Control Air Filter Assemblies',#6556,$,$); +#6559=IFCCLASSIFICATIONREFERENCE($,'23-27 57 27 13','High Efficiency Air Filters',#6555,$,$); +#6560=IFCCLASSIFICATIONREFERENCE($,'23-27 57 27 15','ULPA Filters',#6555,$,$); +#6561=IFCCLASSIFICATIONREFERENCE($,'23-27 57 27 17','HEPA Filters',#6555,$,$); +#6562=IFCCLASSIFICATIONREFERENCE($,'23-27 57 27 19','Bag Filters',#6555,$,$); +#6563=IFCCLASSIFICATIONREFERENCE($,'23-27 57 27 21','Air Filter Housings',#6555,$,$); +#6564=IFCCLASSIFICATIONREFERENCE($,'23-27 57 27 23','Air Charcoal Filters',#6555,$,$); +#6565=IFCCLASSIFICATIONREFERENCE($,'23-27 57 27 25','Roll Type Filters',#6555,$,$); +#6566=IFCCLASSIFICATIONREFERENCE($,'23-27 57 29','Dust Collectors',#6539,$,$); +#6567=IFCCLASSIFICATIONREFERENCE($,'23-27 57 31','Electronic Air Cleaners',#6539,$,$); +#6568=IFCCLASSIFICATIONREFERENCE($,'23-27 57 33','Air Fresheners',#6539,$,$); +#6569=IFCCLASSIFICATIONREFERENCE($,'23-27 57 35','Air Treatment Components',#6539,$,$); +#6570=IFCCLASSIFICATIONREFERENCE($,'23-27 57 35 11','Air Deodorization Products',#6569,$,$); +#6571=IFCCLASSIFICATIONREFERENCE($,'23-27 57 35 13','Moisture Absorbents',#6569,$,$); +#6572=IFCCLASSIFICATIONREFERENCE($,'23-27 59 00','Recycling Equipment',#6109,$,$); +#6573=IFCCLASSIFICATIONREFERENCE($,'23-27 59 11','Recycling Balers',#6572,$,$); +#6574=IFCCLASSIFICATIONREFERENCE($,'23-27 59 11 11','Recycling Cardboard Balers',#6573,$,$); +#6575=IFCCLASSIFICATIONREFERENCE($,'23-27 59 11 13','Recycling Paper Balers',#6573,$,$); +#6576=IFCCLASSIFICATIONREFERENCE($,'23-27 59 11 15','Recycling Plastic Balers',#6573,$,$); +#6577=IFCCLASSIFICATIONREFERENCE($,'23-27 59 11 17','Recycling Wood Balers',#6573,$,$); +#6578=IFCCLASSIFICATIONREFERENCE($,'23-27 59 13','Recycling Bins',#6572,$,$); +#6579=IFCCLASSIFICATIONREFERENCE($,'23-27 59 15','Recycling Compactors',#6572,$,$); +#6580=IFCCLASSIFICATIONREFERENCE($,'23-27 59 15 11','Cardboard Compactors',#6579,$,$); +#6581=IFCCLASSIFICATIONREFERENCE($,'23-27 59 15 13','Metal Compactors',#6579,$,$); +#6582=IFCCLASSIFICATIONREFERENCE($,'23-27 59 15 15','Paper Compactors',#6579,$,$); +#6583=IFCCLASSIFICATIONREFERENCE($,'23-27 59 15 17','Plastic Compactors',#6579,$,$); +#6584=IFCCLASSIFICATIONREFERENCE($,'23-27 59 15 19','Trash Compactors',#6579,$,$); +#6585=IFCCLASSIFICATIONREFERENCE($,'23-27 59 15 21','Wood Compactors',#6579,$,$); +#6586=IFCCLASSIFICATIONREFERENCE($,'23-27 61 00','Incinerators',#6109,$,$); +#6587=IFCCLASSIFICATIONREFERENCE($,'23-27 61 11','Trash Incinerators',#6586,$,$); +#6588=IFCCLASSIFICATIONREFERENCE($,'23-27 61 13','Document Incinerators',#6586,$,$); +#6589=IFCCLASSIFICATIONREFERENCE($,'23-27 63 00','Mechanical Insulation and Linings',#6109,$,$); +#6590=IFCCLASSIFICATIONREFERENCE($,'23-27 63 11','Pipe Insulation',#6589,$,$); +#6591=IFCCLASSIFICATIONREFERENCE($,'23-27 63 13','Equipment Insulation Blankets',#6589,$,$); +#6592=IFCCLASSIFICATIONREFERENCE($,'23-27 65 00','Equipment Acoustic Insulation',#6109,$,$); +#6593=IFCCLASSIFICATIONREFERENCE($,'23-27 65 11','Sound Dampening Equipment Mounts',#6592,$,$); +#6594=IFCCLASSIFICATIONREFERENCE($,'23-27 67 00','Corrosion Proofing Equipment',#6109,$,$); +#6595=IFCCLASSIFICATIONREFERENCE($,'23-27 67 11','Zinc Bars',#6594,$,$); +#6596=IFCCLASSIFICATIONREFERENCE($,'23-27 67 13','Zinc Tapes',#6594,$,$); +#6597=IFCCLASSIFICATIONREFERENCE($,'23-27 69 00','Antivibration Mountings',#6109,$,$); +#6598=IFCCLASSIFICATIONREFERENCE($,'23-27 69 11','Vibration Equipment Mounts',#6597,$,$); +#6599=IFCCLASSIFICATIONREFERENCE($,'23-27 71 00','Building Maintenance Equipment',#6109,$,$); +#6600=IFCCLASSIFICATIONREFERENCE($,'23-27 71 11','Window Washing Systems',#6599,$,$); +#6601=IFCCLASSIFICATIONREFERENCE($,'23-27 71 13','Building Maintenance Cradles and Platforms',#6599,$,$); +#6602=IFCCLASSIFICATIONREFERENCE($,'23-27 71 15','Roof Trolley Systems',#6599,$,$); +#6603=IFCCLASSIFICATIONREFERENCE($,'23-27 71 17','Traveling Ladder Systems',#6599,$,$); +#6604=IFCCLASSIFICATIONREFERENCE($,'23-27 71 19','Ancillary Building Maintenance Items',#6599,$,$); +#6605=IFCCLASSIFICATIONREFERENCE($,'23-27 71 19 11','Building Safety Tracks',#6604,$,$); +#6606=IFCCLASSIFICATIONREFERENCE($,'23-27 71 19 13','Anchors for Building Maintenance',#6604,$,$); +#6607=IFCCLASSIFICATIONREFERENCE($,'23-27 71 21','Fall Arrest Systems',#6599,$,$); +#6608=IFCCLASSIFICATIONREFERENCE($,'23-29 00 00','Facility and Occupant Protection Products',#1606,$,$); +#6609=IFCCLASSIFICATIONREFERENCE($,'23-29 11 00','Security Detection and Monitoring',#6608,$,$); +#6610=IFCCLASSIFICATIONREFERENCE($,'23-29 11 11','Closed Circuit Television Equipment',#6609,$,$); +#6611=IFCCLASSIFICATIONREFERENCE($,'23-29 11 11 11','Infra Red CCTV Cameras',#6610,$,$); +#6612=IFCCLASSIFICATIONREFERENCE($,'23-29 11 11 13','Visual Light Wavelength CCTV Cameras',#6610,$,$); +#6613=IFCCLASSIFICATIONREFERENCE($,'23-29 11 11 15','CCTV Camera Enclosures',#6610,$,$); +#6614=IFCCLASSIFICATIONREFERENCE($,'23-29 11 11 17','Security Camera Controllers',#6610,$,$); +#6615=IFCCLASSIFICATIONREFERENCE($,'23-29 11 11 19','Security Camera Multiplexors',#6610,$,$); +#6616=IFCCLASSIFICATIONREFERENCE($,'23-29 11 11 21','Security Camera Monitoring System Panels',#6610,$,$); +#6617=IFCCLASSIFICATIONREFERENCE($,'23-29 11 13','Security Video Imaging System Equipment',#6609,$,$); +#6618=IFCCLASSIFICATIONREFERENCE($,'23-29 11 13 11','Security Video Monitors',#6617,$,$); +#6619=IFCCLASSIFICATIONREFERENCE($,'23-29 11 13 13','Security Video Recorders',#6617,$,$); +#6620=IFCCLASSIFICATIONREFERENCE($,'23-29 11 13 13 11','Security Analog Video Recorders',#6619,$,$); +#6621=IFCCLASSIFICATIONREFERENCE($,'23-29 11 13 13 13','Security Digital Video Recorders',#6619,$,$); +#6622=IFCCLASSIFICATIONREFERENCE($,'23-29 11 15','Explosive Detectors',#6609,$,$); +#6623=IFCCLASSIFICATIONREFERENCE($,'23-29 11 15 11','Explosive Detector Sniffers',#6622,$,$); +#6624=IFCCLASSIFICATIONREFERENCE($,'23-29 11 15 11 11','Chemical Explosive Detectors',#6623,$,$); +#6625=IFCCLASSIFICATIONREFERENCE($,'23-29 11 15 11 13','Particulate Explosive Detectors',#6623,$,$); +#6626=IFCCLASSIFICATIONREFERENCE($,'23-29 11 15 13','Explosive Detector Spectral Analyzers',#6622,$,$); +#6627=IFCCLASSIFICATIONREFERENCE($,'23-29 11 17','Security Metal Detectors',#6609,$,$); +#6628=IFCCLASSIFICATIONREFERENCE($,'23-29 11 17 11','Security Weather Resistant Walk Through Metal Detectors',#6627,$,$); +#6629=IFCCLASSIFICATIONREFERENCE($,'23-29 11 17 13','Security Indoor Walk Through Metal Detectors',#6627,$,$); +#6630=IFCCLASSIFICATIONREFERENCE($,'23-29 11 17 15','Security Hand Held Metal Detectors',#6627,$,$); +#6631=IFCCLASSIFICATIONREFERENCE($,'23-29 11 19','Security X Ray Machines',#6609,$,$); +#6632=IFCCLASSIFICATIONREFERENCE($,'23-29 11 19 11','Security X Ray Conveyor Machines',#6631,$,$); +#6633=IFCCLASSIFICATIONREFERENCE($,'23-29 11 19 13','Security Personnel X Ray Machines',#6631,$,$); +#6634=IFCCLASSIFICATIONREFERENCE($,'23-29 11 21','Security Sensors',#6609,$,$); +#6635=IFCCLASSIFICATIONREFERENCE($,'23-29 11 21 11','Audio Security Sensors',#6634,$,$); +#6636=IFCCLASSIFICATIONREFERENCE($,'23-29 11 21 13','Security Ground Loop Sensors',#6634,$,$); +#6637=IFCCLASSIFICATIONREFERENCE($,'23-29 11 21 15','Infra Red Security Sensors',#6634,$,$); +#6638=IFCCLASSIFICATIONREFERENCE($,'23-29 11 21 17','Ultrasonic Security Sensors',#6634,$,$); +#6639=IFCCLASSIFICATIONREFERENCE($,'23-29 11 21 19','Security Vibration Sensors',#6634,$,$); +#6640=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23','Intrusion Detection Devices',#6609,$,$); +#6641=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23 11','Intrusion Detection Buried Cables',#6640,$,$); +#6642=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23 13','Intrusion Detection Fiber Optic Fence Line Loops',#6640,$,$); +#6643=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23 15','Intrusion Detection Microwave Alarms',#6640,$,$); +#6644=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23 17','Intrusion Detection Photoelectric Sensors',#6640,$,$); +#6645=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23 19','Intrusion Detection Door Monitoring Switches',#6640,$,$); +#6646=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23 21','Pressure Mats',#6640,$,$); +#6647=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23 23','Door Micro Switch Contacts',#6640,$,$); +#6648=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23 25','Window Micro Switch Contacts',#6640,$,$); +#6649=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23 27','Break Glass Detection',#6640,$,$); +#6650=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23 29','Movement Vibration Detection',#6640,$,$); +#6651=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23 31','Infra Red Radiation Personnel Detectors',#6640,$,$); +#6652=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23 33','Microwave Personnel Detectors',#6640,$,$); +#6653=IFCCLASSIFICATIONREFERENCE($,'23-29 11 23 35','Security Autodialers',#6640,$,$); +#6654=IFCCLASSIFICATIONREFERENCE($,'23-29 11 25','Presence Detection Registration',#6609,$,$); +#6655=IFCCLASSIFICATIONREFERENCE($,'23-29 11 25 11','Personnel Clocking In and Recording Equipment',#6654,$,$); +#6656=IFCCLASSIFICATIONREFERENCE($,'23-29 11 25 13','Surveillance Mirrors',#6654,$,$); +#6657=IFCCLASSIFICATIONREFERENCE($,'23-29 11 25 15','Manual Alert Control',#6654,$,$); +#6658=IFCCLASSIFICATIONREFERENCE($,'23-29 11 25 17','Security Door Bells',#6654,$,$); +#6659=IFCCLASSIFICATIONREFERENCE($,'23-29 11 25 19','Security Buzzers',#6654,$,$); +#6660=IFCCLASSIFICATIONREFERENCE($,'23-29 11 27','Security Keypads',#6609,$,$); +#6661=IFCCLASSIFICATIONREFERENCE($,'23-29 11 27 11','Alarm Keypads',#6660,$,$); +#6662=IFCCLASSIFICATIONREFERENCE($,'23-29 11 27 13','Security Keypads',#6660,$,$); +#6663=IFCCLASSIFICATIONREFERENCE($,'23-29 11 29','Vehicle Inspection Devices',#6609,$,$); +#6664=IFCCLASSIFICATIONREFERENCE($,'23-29 11 29 11','Undercarriage Inspection Lighting',#6663,$,$); +#6665=IFCCLASSIFICATIONREFERENCE($,'23-29 13 00','Security Access Controls',#6608,$,$); +#6666=IFCCLASSIFICATIONREFERENCE($,'23-29 13 11','Personnel Biometric Readers',#6665,$,$); +#6667=IFCCLASSIFICATIONREFERENCE($,'23-29 13 11 11','Fingerprint Readers',#6666,$,$); +#6668=IFCCLASSIFICATIONREFERENCE($,'23-29 13 11 13','Hand Geometry Readers',#6666,$,$); +#6669=IFCCLASSIFICATIONREFERENCE($,'23-29 13 11 15','Iris Scanners',#6666,$,$); +#6670=IFCCLASSIFICATIONREFERENCE($,'23-29 13 11 17','Retinal Scanners',#6666,$,$); +#6671=IFCCLASSIFICATIONREFERENCE($,'23-29 13 11 19','Vein Recognition Readers',#6666,$,$); +#6672=IFCCLASSIFICATIONREFERENCE($,'23-29 13 13','Personnel Card Readers',#6665,$,$); +#6673=IFCCLASSIFICATIONREFERENCE($,'23-29 13 13 11','Personnel Contact Card Readers',#6672,$,$); +#6674=IFCCLASSIFICATIONREFERENCE($,'23-29 13 13 11 11','Mag Stripe Personnel Contact Card Readers',#6673,$,$); +#6675=IFCCLASSIFICATIONREFERENCE($,'23-29 13 13 11 13','Smart Card Personnel Contact Card Readers',#6673,$,$); +#6676=IFCCLASSIFICATIONREFERENCE($,'23-29 13 13 11 15','Weigand Personnel Contact Card Readers',#6673,$,$); +#6677=IFCCLASSIFICATIONREFERENCE($,'23-29 13 13 13','Personnel Contactless Card Readers',#6672,$,$); +#6678=IFCCLASSIFICATIONREFERENCE($,'23-29 13 13 13 11','Barcode Personnel Contactless Card Readers',#6677,$,$); +#6679=IFCCLASSIFICATIONREFERENCE($,'23-29 13 13 13 13','Near Field Proximity Personnel Contactless Card Readers',#6677,$,$); +#6680=IFCCLASSIFICATIONREFERENCE($,'23-29 13 13 13 15','Proximity Personnel Contactless Card Readers',#6677,$,$); +#6681=IFCCLASSIFICATIONREFERENCE($,'23-29 13 15','Personnel Counting Equipment',#6665,$,$); +#6682=IFCCLASSIFICATIONREFERENCE($,'23-29 13 17','Security Door Answering Controls',#6665,$,$); +#6683=IFCCLASSIFICATIONREFERENCE($,'23-29 13 19','Electronic Key Equipment',#6665,$,$); +#6684=IFCCLASSIFICATIONREFERENCE($,'23-29 13 21','Security Personnel Access Keypads',#6665,$,$); +#6685=IFCCLASSIFICATIONREFERENCE($,'23-29 13 23','Access Control Turnstiles',#6665,$,$); +#6686=IFCCLASSIFICATIONREFERENCE($,'23-29 13 23 11','Waist Height Turnstiles',#6685,$,$); +#6687=IFCCLASSIFICATIONREFERENCE($,'23-29 13 23 13','Full Height Turnstiles',#6685,$,$); +#6688=IFCCLASSIFICATIONREFERENCE($,'23-29 13 23 15','Portable Post and Railing Barriers',#6685,$,$); +#6689=IFCCLASSIFICATIONREFERENCE($,'23-29 15 00','Secure Storage Structures and Products',#6608,$,$); +#6690=IFCCLASSIFICATIONREFERENCE($,'23-29 15 11','Vaults',#6689,$,$); +#6691=IFCCLASSIFICATIONREFERENCE($,'23-29 15 11 11','Prefabricated Room Vaults',#6690,$,$); +#6692=IFCCLASSIFICATIONREFERENCE($,'23-29 15 11 13','Commercial Vaults',#6690,$,$); +#6693=IFCCLASSIFICATIONREFERENCE($,'23-29 15 11 15','Residential Vaults',#6690,$,$); +#6694=IFCCLASSIFICATIONREFERENCE($,'23-29 15 13','Safes',#6689,$,$); +#6695=IFCCLASSIFICATIONREFERENCE($,'23-29 15 13 11','Commercial Safes',#6694,$,$); +#6696=IFCCLASSIFICATIONREFERENCE($,'23-29 15 13 13','Residential Safes',#6694,$,$); +#6697=IFCCLASSIFICATIONREFERENCE($,'23-29 15 15','Lockers',#6689,$,$); +#6698=IFCCLASSIFICATIONREFERENCE($,'23-29 15 15 11','Metal Lockers',#6697,$,$); +#6699=IFCCLASSIFICATIONREFERENCE($,'23-29 15 15 13','Wood Lockers',#6697,$,$); +#6700=IFCCLASSIFICATIONREFERENCE($,'23-29 15 15 15','Plastic Laminate Clad Lockers',#6697,$,$); +#6701=IFCCLASSIFICATIONREFERENCE($,'23-29 15 15 17','Plastic Lockers',#6697,$,$); +#6702=IFCCLASSIFICATIONREFERENCE($,'23-29 15 15 19','Glass Lockers',#6697,$,$); +#6703=IFCCLASSIFICATIONREFERENCE($,'23-29 15 15 21','Wire Mesh Storage Lockers',#6697,$,$); +#6704=IFCCLASSIFICATIONREFERENCE($,'23-29 17 00','Property Storage Locks',#6608,$,$); +#6705=IFCCLASSIFICATIONREFERENCE($,'23-29 17 11','Bicycle Locks',#6704,$,$); +#6706=IFCCLASSIFICATIONREFERENCE($,'23-29 17 13','Padlocks',#6704,$,$); +#6707=IFCCLASSIFICATIONREFERENCE($,'23-29 17 13 11','Combination Padlocks',#6706,$,$); +#6708=IFCCLASSIFICATIONREFERENCE($,'23-29 17 13 13','Pin Tumbler Padlocks',#6706,$,$); +#6709=IFCCLASSIFICATIONREFERENCE($,'23-29 19 00','Chemical Biological Radiological Protection',#6608,$,$); +#6710=IFCCLASSIFICATIONREFERENCE($,'23-29 19 11','Prefabricated Mail Screening Products',#6709,$,$); +#6711=IFCCLASSIFICATIONREFERENCE($,'23-29 19 13','Biological Safety Cabinets',#6709,$,$); +#6712=IFCCLASSIFICATIONREFERENCE($,'23-29 21 00','Equipment for Security of Information',#6608,$,$); +#6713=IFCCLASSIFICATIONREFERENCE($,'23-29 21 11','Centralized Code Reading Equipment',#6712,$,$); +#6714=IFCCLASSIFICATIONREFERENCE($,'23-29 23 00','Fireproofing Components',#6608,$,$); +#6715=IFCCLASSIFICATIONREFERENCE($,'23-29 23 11','Fireproofing Gaskets',#6714,$,$); +#6716=IFCCLASSIFICATIONREFERENCE($,'23-29 23 13','Fireproofing Fillers for Threaded Couplings',#6714,$,$); +#6717=IFCCLASSIFICATIONREFERENCE($,'23-29 23 15','Fireproof Pipe Sleeves',#6714,$,$); +#6718=IFCCLASSIFICATIONREFERENCE($,'23-29 23 17','Smoke Seals for Ductwork',#6714,$,$); +#6719=IFCCLASSIFICATIONREFERENCE($,'23-29 25 00','Fire Fighting Equipment',#6608,$,$); +#6720=IFCCLASSIFICATIONREFERENCE($,'23-29 25 11','Fire Fighting Terminals',#6719,$,$); +#6721=IFCCLASSIFICATIONREFERENCE($,'23-29 25 11 11','Fire Fighting Terminal Components',#6720,$,$); +#6722=IFCCLASSIFICATIONREFERENCE($,'23-29 25 11 13','Water Fire Fighting Terminals',#6720,$,$); +#6723=IFCCLASSIFICATIONREFERENCE($,'23-29 25 11 15','Gaseous Fire Fighting Terminals',#6720,$,$); +#6724=IFCCLASSIFICATIONREFERENCE($,'23-29 25 11 17','Foam Fire Fighting Terminals',#6720,$,$); +#6725=IFCCLASSIFICATIONREFERENCE($,'23-29 25 11 19','Powder Fire Fighting Terminals',#6720,$,$); +#6726=IFCCLASSIFICATIONREFERENCE($,'23-29 25 11 21','Fire Fighting Media',#6720,$,$); +#6727=IFCCLASSIFICATIONREFERENCE($,'23-29 25 11 23','Fire Fighting Gas Terminals',#6720,$,$); +#6728=IFCCLASSIFICATIONREFERENCE($,'23-29 25 13','Fire Hydrants',#6719,$,$); +#6729=IFCCLASSIFICATIONREFERENCE($,'23-29 25 13 11','Dry Barrel Fire Hydrants',#6728,$,$); +#6730=IFCCLASSIFICATIONREFERENCE($,'23-29 25 13 13','Wet Barrel Fire Hydrants',#6728,$,$); +#6731=IFCCLASSIFICATIONREFERENCE($,'23-29 25 15','Fire Hose Equipment',#6719,$,$); +#6732=IFCCLASSIFICATIONREFERENCE($,'23-29 25 15 11','Fire Hoses',#6731,$,$); +#6733=IFCCLASSIFICATIONREFERENCE($,'23-29 25 15 13','Fire Hose Outlets',#6731,$,$); +#6734=IFCCLASSIFICATIONREFERENCE($,'23-29 25 15 15','Cabinets for Fire Hoses',#6731,$,$); +#6735=IFCCLASSIFICATIONREFERENCE($,'23-29 25 15 17','Fire Hose Reels',#6731,$,$); +#6736=IFCCLASSIFICATIONREFERENCE($,'23-29 25 15 19','Fire Hose Connectors',#6731,$,$); +#6737=IFCCLASSIFICATIONREFERENCE($,'23-29 25 15 19 11','Fire Fighting Standpipes',#6736,$,$); +#6738=IFCCLASSIFICATIONREFERENCE($,'23-29 25 15 19 13','Fire Fighting Pumper Connections',#6736,$,$); +#6739=IFCCLASSIFICATIONREFERENCE($,'23-29 25 17','Fire Nozzles',#6719,$,$); +#6740=IFCCLASSIFICATIONREFERENCE($,'23-29 25 17 11','Fire Fog Nozzles',#6739,$,$); +#6741=IFCCLASSIFICATIONREFERENCE($,'23-29 25 17 13','Fire Stream Nozzles',#6739,$,$); +#6742=IFCCLASSIFICATIONREFERENCE($,'23-29 25 17 15','Fire Electrical Rated Nozzles',#6739,$,$); +#6743=IFCCLASSIFICATIONREFERENCE($,'23-29 25 19','Fire Extinguishers',#6719,$,$); +#6744=IFCCLASSIFICATIONREFERENCE($,'23-29 25 19 11','Stored Pressure Fire Extinguishers',#6743,$,$); +#6745=IFCCLASSIFICATIONREFERENCE($,'23-29 25 19 11 11','Stored Pressure Fire Extinguishers With Gauge',#6744,$,$); +#6746=IFCCLASSIFICATIONREFERENCE($,'23-29 25 19 13','Non Stainless Steel Fire Extinguishers',#6743,$,$); +#6747=IFCCLASSIFICATIONREFERENCE($,'23-29 25 19 15','Non Rechargeable Fire Extinguishers',#6743,$,$); +#6748=IFCCLASSIFICATIONREFERENCE($,'23-29 25 19 17','Gas Cart Fire Extinguishers',#6743,$,$); +#6749=IFCCLASSIFICATIONREFERENCE($,'23-29 25 19 17 11','Gas Cart Fire Extinguishers With Gauge',#6748,$,$); +#6750=IFCCLASSIFICATIONREFERENCE($,'23-29 25 19 19','Foam Fire Extinguishers',#6743,$,$); +#6751=IFCCLASSIFICATIONREFERENCE($,'23-29 27 00','Fire Ventilation Equipment',#6608,$,$); +#6752=IFCCLASSIFICATIONREFERENCE($,'23-29 27 11','Fire Fighting Smoke Extractors',#6751,$,$); +#6753=IFCCLASSIFICATIONREFERENCE($,'23-29 29 00','Fire Detection Devices',#6608,$,$); +#6754=IFCCLASSIFICATIONREFERENCE($,'23-29 29 11','Fire Alarm Pull Stations',#6753,$,$); +#6755=IFCCLASSIFICATIONREFERENCE($,'23-29 29 11 11','Addressable Fire Alarm Pull Stations',#6754,$,$); +#6756=IFCCLASSIFICATIONREFERENCE($,'23-29 29 11 13','Non Addressable Fire Alarm Pull Stations',#6754,$,$); +#6757=IFCCLASSIFICATIONREFERENCE($,'23-29 29 13','Fire Detectors',#6753,$,$); +#6758=IFCCLASSIFICATIONREFERENCE($,'23-29 29 13 11','Smoke Detectors',#6757,$,$); +#6759=IFCCLASSIFICATIONREFERENCE($,'23-29 29 13 11 11','Spot Type Photoelectric Smoke Detectors',#6758,$,$); +#6760=IFCCLASSIFICATIONREFERENCE($,'23-29 29 13 11 13','Spot Type Ionization Smoke Detectors',#6758,$,$); +#6761=IFCCLASSIFICATIONREFERENCE($,'23-29 29 13 11 15','Spot Type Duct Photoelectric Smoke Detectors',#6758,$,$); +#6762=IFCCLASSIFICATIONREFERENCE($,'23-29 29 13 11 17','Spot Type Duct Ionization Smoke Detectors',#6758,$,$); +#6763=IFCCLASSIFICATIONREFERENCE($,'23-29 29 13 11 19','Beam Type Smoke Detectors',#6758,$,$); +#6764=IFCCLASSIFICATIONREFERENCE($,'23-29 29 13 13','Heat Detectors',#6757,$,$); +#6765=IFCCLASSIFICATIONREFERENCE($,'23-29 29 13 13 11','Fixed Temperature Heat Detectors',#6764,$,$); +#6766=IFCCLASSIFICATIONREFERENCE($,'23-29 29 13 13 13','Rate of Rise Heat Detectors',#6764,$,$); +#6767=IFCCLASSIFICATIONREFERENCE($,'23-29 29 13 15','Flame Detectors',#6757,$,$); +#6768=IFCCLASSIFICATIONREFERENCE($,'23-29 29 13 17','Spark and Ember Detectors',#6757,$,$); +#6769=IFCCLASSIFICATIONREFERENCE($,'23-29 29 13 19','Radiant Energy Detectors',#6757,$,$); +#6770=IFCCLASSIFICATIONREFERENCE($,'23-29 29 15','Fire Switches',#6753,$,$); +#6771=IFCCLASSIFICATIONREFERENCE($,'23-29 29 15 11','Pressure Fire Alarm Water Flow Switches',#6770,$,$); +#6772=IFCCLASSIFICATIONREFERENCE($,'23-29 29 15 13','Paddle Fire Alarm Water Flow Switches',#6770,$,$); +#6773=IFCCLASSIFICATIONREFERENCE($,'23-29 29 15 15','Fire Tamper Switches',#6770,$,$); +#6774=IFCCLASSIFICATIONREFERENCE($,'23-29 31 00','Fire Notification Appliances',#6608,$,$); +#6775=IFCCLASSIFICATIONREFERENCE($,'23-29 31 11','Fire Alarm Annunicator Panels',#6774,$,$); +#6776=IFCCLASSIFICATIONREFERENCE($,'23-29 31 11 11','Audible Fire Alarm Annunicator Panels',#6775,$,$); +#6777=IFCCLASSIFICATIONREFERENCE($,'23-29 31 11 13','Visible Fire Alarm Annunicator Panels',#6775,$,$); +#6778=IFCCLASSIFICATIONREFERENCE($,'23-29 31 11 15','Combination Fire Alarm Annunicator Panels',#6775,$,$); +#6779=IFCCLASSIFICATIONREFERENCE($,'23-29 31 13','Fire Alarm Control Panels',#6774,$,$); +#6780=IFCCLASSIFICATIONREFERENCE($,'23-29 31 13 11','Main Fire Alarm Control Panels',#6779,$,$); +#6781=IFCCLASSIFICATIONREFERENCE($,'23-29 31 13 13','Secondary Fire Alarm Control Panels',#6779,$,$); +#6782=IFCCLASSIFICATIONREFERENCE($,'23-29 31 13 15','Fire Alarm Audio Control Panels',#6779,$,$); +#6783=IFCCLASSIFICATIONREFERENCE($,'23-29 31 13 17','Fire Alarm Smoke Control Panels',#6779,$,$); +#6784=IFCCLASSIFICATIONREFERENCE($,'23-29 31 15','Audible Fire Notification Devices',#6774,$,$); +#6785=IFCCLASSIFICATIONREFERENCE($,'23-29 31 15 11','Audible Fire Notification Devices Bell',#6784,$,$); +#6786=IFCCLASSIFICATIONREFERENCE($,'23-29 31 15 13','Audible Fire Notification Devices Horn',#6784,$,$); +#6787=IFCCLASSIFICATIONREFERENCE($,'23-29 31 15 15','Audible Fire Notification Devices Chime',#6784,$,$); +#6788=IFCCLASSIFICATIONREFERENCE($,'23-29 31 15 17','Audible Fire Notification Devices Speaker',#6784,$,$); +#6789=IFCCLASSIFICATIONREFERENCE($,'23-29 31 17','Visible Fire Notification Devices',#6774,$,$); +#6790=IFCCLASSIFICATIONREFERENCE($,'23-29 31 17 11','Visible Fire Notification Device Lights',#6789,$,$); +#6791=IFCCLASSIFICATIONREFERENCE($,'23-29 31 19','Combination Audible and Visible Fire Notification Devices',#6774,$,$); +#6792=IFCCLASSIFICATIONREFERENCE($,'23-29 31 21','Fire Alarm Communicators',#6774,$,$); +#6793=IFCCLASSIFICATIONREFERENCE($,'23-29 31 23','Fire Alarm Central Stations',#6774,$,$); +#6794=IFCCLASSIFICATIONREFERENCE($,'23-29 31 23 11','Fire Alarm Central Station Transmitters',#6793,$,$); +#6795=IFCCLASSIFICATIONREFERENCE($,'23-29 31 23 13','Fire Alarm Central Station Receivers',#6793,$,$); +#6796=IFCCLASSIFICATIONREFERENCE($,'23-29 31 23 15','Fire Alarm Central Station Combination Transmitter and Receivers',#6793,$,$); +#6797=IFCCLASSIFICATIONREFERENCE($,'23-29 31 25','Fire Alarm Event Recorders',#6774,$,$); +#6798=IFCCLASSIFICATIONREFERENCE($,'23-29 31 27','Fire Alarm Event Printers',#6774,$,$); +#6799=IFCCLASSIFICATIONREFERENCE($,'23-29 31 29','Fire Alarm Remote Controllers',#6774,$,$); +#6800=IFCCLASSIFICATIONREFERENCE($,'23-29 31 31','Fire Alarm Remote Amplifiers',#6774,$,$); +#6801=IFCCLASSIFICATIONREFERENCE($,'23-29 31 33','Fire Pump Controllers',#6774,$,$); +#6802=IFCCLASSIFICATIONREFERENCE($,'23-29 31 35','Jockey Pump Controllers',#6774,$,$); +#6803=IFCCLASSIFICATIONREFERENCE($,'23-29 33 00','Fire Suppression System Components',#6608,$,$); +#6804=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11','Water Based Suppression Equipment',#6803,$,$); +#6805=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11 11','Pendant Sprinkler Heads',#6804,$,$); +#6806=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11 11 11','Wet Pendant Sprinkler Heads',#6805,$,$); +#6807=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11 11 13','Dry Pendant Sprinkler Heads',#6805,$,$); +#6808=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11 11 15','Open Pendant Sprinkler Heads',#6805,$,$); +#6809=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11 13','Upright Sprinkler Heads',#6804,$,$); +#6810=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11 13 11','Wet Upright Sprinkler Heads',#6809,$,$); +#6811=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11 13 13','Dry Upright Sprinkler Heads',#6809,$,$); +#6812=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11 13 15','Open Upright Sprinkler Heads',#6809,$,$); +#6813=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11 15','Side Wall Sprinkler Heads',#6804,$,$); +#6814=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11 15 11','Wet Side Wall Sprinkler Heads',#6813,$,$); +#6815=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11 15 13','Dry Side Wall Sprinkler Heads',#6813,$,$); +#6816=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11 17','Dry Pipe Valves',#6804,$,$); +#6817=IFCCLASSIFICATIONREFERENCE($,'23-29 33 11 19','Water Mist Systems',#6804,$,$); +#6818=IFCCLASSIFICATIONREFERENCE($,'23-29 33 13','Non Water Based Suppression Equipment',#6803,$,$); +#6819=IFCCLASSIFICATIONREFERENCE($,'23-29 33 13 11','Clean Agent Gaseous Suppression Equipment',#6818,$,$); +#6820=IFCCLASSIFICATIONREFERENCE($,'23-29 33 13 13','Carbon Dioxide Suppression Equipment',#6818,$,$); +#6821=IFCCLASSIFICATIONREFERENCE($,'23-29 33 13 15','Halon Suppression Equipment',#6818,$,$); +#6822=IFCCLASSIFICATIONREFERENCE($,'23-29 33 13 17','Wet Chemical Fire Suppression Equipment',#6818,$,$); +#6823=IFCCLASSIFICATIONREFERENCE($,'23-29 33 13 19','Dry Chemical Fire Suppression Equipment',#6818,$,$); +#6824=IFCCLASSIFICATIONREFERENCE($,'23-29 33 13 21','Foam Fire Suppression Equipment',#6818,$,$); +#6825=IFCCLASSIFICATIONREFERENCE($,'23-29 33 15','Fire Blankets',#6803,$,$); +#6826=IFCCLASSIFICATIONREFERENCE($,'23-29 35 00','Fire Rescue Component',#6608,$,$); +#6827=IFCCLASSIFICATIONREFERENCE($,'23-29 35 11','Evacuation Chairs',#6826,$,$); +#6828=IFCCLASSIFICATIONREFERENCE($,'23-29 35 13','Evacuation Slides',#6826,$,$); +#6829=IFCCLASSIFICATIONREFERENCE($,'23-29 37 00','Occupational Safety and Health Equipment',#6608,$,$); +#6830=IFCCLASSIFICATIONREFERENCE($,'23-29 37 11','Emergency Drench Hoses',#6829,$,$); +#6831=IFCCLASSIFICATIONREFERENCE($,'23-29 37 13','Emergency Eye Wash Stations',#6829,$,$); +#6832=IFCCLASSIFICATIONREFERENCE($,'23-29 37 13 11','Counter Top Eye Wash Stations',#6831,$,$); +#6833=IFCCLASSIFICATIONREFERENCE($,'23-29 37 13 13','Floor Mounted Eye Wash Stations',#6831,$,$); +#6834=IFCCLASSIFICATIONREFERENCE($,'23-29 37 13 15','Combination Emergency Eye Wash Stations',#6831,$,$); +#6835=IFCCLASSIFICATIONREFERENCE($,'23-29 37 13 17','Dedicated Emergency Eye Wash Stations',#6831,$,$); +#6836=IFCCLASSIFICATIONREFERENCE($,'23-29 37 15','Emergency Showers',#6829,$,$); +#6837=IFCCLASSIFICATIONREFERENCE($,'23-29 37 15 11','Combination Emergency Showers',#6836,$,$); +#6838=IFCCLASSIFICATIONREFERENCE($,'23-29 37 15 13','Dedicated Emergency Showers',#6836,$,$); +#6839=IFCCLASSIFICATIONREFERENCE($,'23-29 39 00','Environmental Safety Equipment',#6608,$,$); +#6840=IFCCLASSIFICATIONREFERENCE($,'23-29 39 11','Environmental Spill Kits',#6839,$,$); +#6841=IFCCLASSIFICATIONREFERENCE($,'23-29 39 13','Pollution Monitoring and Control',#6839,$,$); +#6842=IFCCLASSIFICATIONREFERENCE($,'23-29 39 13 11','Air Pollution Monitoring Systems',#6841,$,$); +#6843=IFCCLASSIFICATIONREFERENCE($,'23-29 39 13 13','Water Pollution Monitoring Systems',#6841,$,$); +#6844=IFCCLASSIFICATIONREFERENCE($,'23-29 39 15','Built In Failure Detection',#6839,$,$); +#6845=IFCCLASSIFICATIONREFERENCE($,'23-29 39 15 11','Infiltration Detection',#6844,$,$); +#6846=IFCCLASSIFICATIONREFERENCE($,'23-29 39 15 13','Service Leak Detection',#6844,$,$); +#6847=IFCCLASSIFICATIONREFERENCE($,'23-29 39 15 13 11','Gas Leak Detection Agents',#6846,$,$); +#6848=IFCCLASSIFICATIONREFERENCE($,'23-29 39 15 13 13','Water Leak Detection',#6846,$,$); +#6849=IFCCLASSIFICATIONREFERENCE($,'23-31 00 00','Plumbing Specific Products and Equipment',#1606,$,$); +#6850=IFCCLASSIFICATIONREFERENCE($,'23-31 11 00','Faucets',#6849,$,$); +#6851=IFCCLASSIFICATIONREFERENCE($,'23-31 11 11','Ball Faucets',#6850,$,$); +#6852=IFCCLASSIFICATIONREFERENCE($,'23-31 11 11 11','Sink Ball Faucets',#6851,$,$); +#6853=IFCCLASSIFICATIONREFERENCE($,'23-31 11 11 13','Bathtub Ball Faucets',#6851,$,$); +#6854=IFCCLASSIFICATIONREFERENCE($,'23-31 11 11 15','Shower Ball Faucets',#6851,$,$); +#6855=IFCCLASSIFICATIONREFERENCE($,'23-31 11 13','Compression Faucets',#6850,$,$); +#6856=IFCCLASSIFICATIONREFERENCE($,'23-31 11 13 11','Sink Compression Faucets',#6855,$,$); +#6857=IFCCLASSIFICATIONREFERENCE($,'23-31 11 13 13','Bathtub Compression Faucets',#6855,$,$); +#6858=IFCCLASSIFICATIONREFERENCE($,'23-31 11 13 15','Shower Compression Faucets',#6855,$,$); +#6859=IFCCLASSIFICATIONREFERENCE($,'23-31 11 15','Cartridge Faucets',#6850,$,$); +#6860=IFCCLASSIFICATIONREFERENCE($,'23-31 11 15 11','Sink Cartridge Faucets',#6859,$,$); +#6861=IFCCLASSIFICATIONREFERENCE($,'23-31 11 15 13','Bathtub Cartridge Faucets',#6859,$,$); +#6862=IFCCLASSIFICATIONREFERENCE($,'23-31 11 15 15','Shower Cartridge Faucets',#6859,$,$); +#6863=IFCCLASSIFICATIONREFERENCE($,'23-31 11 17','Disc Faucets',#6850,$,$); +#6864=IFCCLASSIFICATIONREFERENCE($,'23-31 11 17 11','Sink Disc Faucets',#6863,$,$); +#6865=IFCCLASSIFICATIONREFERENCE($,'23-31 11 17 13','Bathtub Disc Faucets',#6863,$,$); +#6866=IFCCLASSIFICATIONREFERENCE($,'23-31 11 17 15','Shower Disc Faucets',#6863,$,$); +#6867=IFCCLASSIFICATIONREFERENCE($,'23-31 11 19','Faucet Mixing Valves',#6850,$,$); +#6868=IFCCLASSIFICATIONREFERENCE($,'23-31 11 19 11','Thermostatically Controlled Faucet Mixing Valves',#6867,$,$); +#6869=IFCCLASSIFICATIONREFERENCE($,'23-31 11 19 13','Pressure Sensitive Faucet Mixing Valves',#6867,$,$); +#6870=IFCCLASSIFICATIONREFERENCE($,'23-31 11 19 15','Pressure Balanced Faucet Mixing Valves',#6867,$,$); +#6871=IFCCLASSIFICATIONREFERENCE($,'23-31 13 00','Sinks',#6849,$,$); +#6872=IFCCLASSIFICATIONREFERENCE($,'23-31 13 11','Single Sinks',#6871,$,$); +#6873=IFCCLASSIFICATIONREFERENCE($,'23-31 13 13','Dual Sinks',#6871,$,$); +#6874=IFCCLASSIFICATIONREFERENCE($,'23-31 13 15','Multiple Sinks',#6871,$,$); +#6875=IFCCLASSIFICATIONREFERENCE($,'23-31 13 17','Sink Components',#6871,$,$); +#6876=IFCCLASSIFICATIONREFERENCE($,'23-31 13 17 11','Sink Splashbacks',#6875,$,$); +#6877=IFCCLASSIFICATIONREFERENCE($,'23-31 13 17 13','Sink Drains',#6875,$,$); +#6878=IFCCLASSIFICATIONREFERENCE($,'23-31 13 19','Specialty Sinks',#6871,$,$); +#6879=IFCCLASSIFICATIONREFERENCE($,'23-31 13 19 11','Sacristy',#6878,$,$); +#6880=IFCCLASSIFICATIONREFERENCE($,'23-31 13 19 13','Darkroom Sinks',#6878,$,$); +#6881=IFCCLASSIFICATIONREFERENCE($,'23-31 13 19 15','Hairdressing Sinks',#6878,$,$); +#6882=IFCCLASSIFICATIONREFERENCE($,'23-31 13 19 17','Mop Sinks',#6878,$,$); +#6883=IFCCLASSIFICATIONREFERENCE($,'23-31 13 19 19','Service Sinks',#6878,$,$); +#6884=IFCCLASSIFICATIONREFERENCE($,'23-31 15 00','Bathtubs',#6849,$,$); +#6885=IFCCLASSIFICATIONREFERENCE($,'23-31 15 11','Bath Shower Units',#6884,$,$); +#6886=IFCCLASSIFICATIONREFERENCE($,'23-31 15 13','Sitz Baths',#6884,$,$); +#6887=IFCCLASSIFICATIONREFERENCE($,'23-31 15 15','Jacuzzi Baths',#6884,$,$); +#6888=IFCCLASSIFICATIONREFERENCE($,'23-31 15 17','Bathtub Components',#6884,$,$); +#6889=IFCCLASSIFICATIONREFERENCE($,'23-31 15 17 11','Bathtub Enclosures',#6888,$,$); +#6890=IFCCLASSIFICATIONREFERENCE($,'23-31 15 17 13','Bathtub Splashbacks',#6888,$,$); +#6891=IFCCLASSIFICATIONREFERENCE($,'23-31 15 17 15','Bathtub Panels',#6888,$,$); +#6892=IFCCLASSIFICATIONREFERENCE($,'23-31 15 17 17','Bathtub Seats',#6888,$,$); +#6893=IFCCLASSIFICATIONREFERENCE($,'23-31 15 17 19','Bathtub Screens',#6888,$,$); +#6894=IFCCLASSIFICATIONREFERENCE($,'23-31 15 17 21','Bathtub Grab Bars',#6888,$,$); +#6895=IFCCLASSIFICATIONREFERENCE($,'23-31 15 17 23','Bathtub Drains',#6888,$,$); +#6896=IFCCLASSIFICATIONREFERENCE($,'23-31 17 00','Showers',#6849,$,$); +#6897=IFCCLASSIFICATIONREFERENCE($,'23-31 17 11','Shower Compartments',#6896,$,$); +#6898=IFCCLASSIFICATIONREFERENCE($,'23-31 17 13','Shower Receptors',#6896,$,$); +#6899=IFCCLASSIFICATIONREFERENCE($,'23-31 17 15','Shower Enclosure Bases',#6896,$,$); +#6900=IFCCLASSIFICATIONREFERENCE($,'23-31 17 17','Shower Enclosures',#6896,$,$); +#6901=IFCCLASSIFICATIONREFERENCE($,'23-31 17 19','Shower Head Fixtures',#6896,$,$); +#6902=IFCCLASSIFICATIONREFERENCE($,'23-31 17 21','Shower Splashbacks',#6896,$,$); +#6903=IFCCLASSIFICATIONREFERENCE($,'23-31 17 23','Shower Seats',#6896,$,$); +#6904=IFCCLASSIFICATIONREFERENCE($,'23-31 17 25','Shower Screens',#6896,$,$); +#6905=IFCCLASSIFICATIONREFERENCE($,'23-31 17 27','Shower Curtains',#6896,$,$); +#6906=IFCCLASSIFICATIONREFERENCE($,'23-31 17 29','Shower Drains',#6896,$,$); +#6907=IFCCLASSIFICATIONREFERENCE($,'23-31 17 31','Shower Rods',#6896,$,$); +#6908=IFCCLASSIFICATIONREFERENCE($,'23-31 19 00','Toilets',#6849,$,$); +#6909=IFCCLASSIFICATIONREFERENCE($,'23-31 19 11','Combination Toilets',#6908,$,$); +#6910=IFCCLASSIFICATIONREFERENCE($,'23-31 19 11 11','Detention Combination Toilets',#6909,$,$); +#6911=IFCCLASSIFICATIONREFERENCE($,'23-31 19 13','Incinerating Toilets',#6908,$,$); +#6912=IFCCLASSIFICATIONREFERENCE($,'23-31 19 15','Tankless Toilets',#6908,$,$); +#6913=IFCCLASSIFICATIONREFERENCE($,'23-31 19 15 11','Floor Mounted Tankless Toilets',#6912,$,$); +#6914=IFCCLASSIFICATIONREFERENCE($,'23-31 19 15 13','Wall Mounted Tankless Toilets',#6912,$,$); +#6915=IFCCLASSIFICATIONREFERENCE($,'23-31 19 17','Toilets With Tank',#6908,$,$); +#6916=IFCCLASSIFICATIONREFERENCE($,'23-31 19 17 11','Floor Mounted Toilets With Tank',#6915,$,$); +#6917=IFCCLASSIFICATIONREFERENCE($,'23-31 19 17 13','Wall Mounted Toilets With Tank',#6915,$,$); +#6918=IFCCLASSIFICATIONREFERENCE($,'23-31 19 19','Water Closets',#6908,$,$); +#6919=IFCCLASSIFICATIONREFERENCE($,'23-31 19 19 11','Water Operated Water Closets',#6918,$,$); +#6920=IFCCLASSIFICATIONREFERENCE($,'23-31 19 19 13','Chemical Biological Sanitary Disposal Units',#6918,$,$); +#6921=IFCCLASSIFICATIONREFERENCE($,'23-31 19 19 15','Sanitary Macerators',#6918,$,$); +#6922=IFCCLASSIFICATIONREFERENCE($,'23-31 19 19 17','Water Closet Seats',#6918,$,$); +#6923=IFCCLASSIFICATIONREFERENCE($,'23-31 19 19 19','Water Closet Tanks',#6918,$,$); +#6924=IFCCLASSIFICATIONREFERENCE($,'23-31 19 19 21','Sanitary Disposal Connectors',#6918,$,$); +#6925=IFCCLASSIFICATIONREFERENCE($,'23-31 21 00','Urinals',#6849,$,$); +#6926=IFCCLASSIFICATIONREFERENCE($,'23-31 21 11','Incinerating Urinals',#6925,$,$); +#6927=IFCCLASSIFICATIONREFERENCE($,'23-31 21 13','Water Flush Urinals',#6925,$,$); +#6928=IFCCLASSIFICATIONREFERENCE($,'23-31 21 13 11','Floor Water Flush Urinals',#6927,$,$); +#6929=IFCCLASSIFICATIONREFERENCE($,'23-31 21 13 13','Wall Mounted Water Flush Urinals',#6927,$,$); +#6930=IFCCLASSIFICATIONREFERENCE($,'23-31 21 15','Waterless Urinals',#6925,$,$); +#6931=IFCCLASSIFICATIONREFERENCE($,'23-31 21 15 11','Floor Waterless Urinals',#6930,$,$); +#6932=IFCCLASSIFICATIONREFERENCE($,'23-31 21 15 13','Wall Mounted Waterless Urinals',#6930,$,$); +#6933=IFCCLASSIFICATIONREFERENCE($,'23-31 23 00','Bidets',#6849,$,$); +#6934=IFCCLASSIFICATIONREFERENCE($,'23-31 25 00','Toilet and Bath Specialties',#6849,$,$); +#6935=IFCCLASSIFICATIONREFERENCE($,'23-31 25 11','Restroom Partitions',#6934,$,$); +#6936=IFCCLASSIFICATIONREFERENCE($,'23-31 25 11 11','Toilet Partitions',#6935,$,$); +#6937=IFCCLASSIFICATIONREFERENCE($,'23-31 25 11 13','Toilet Door Partitions',#6935,$,$); +#6938=IFCCLASSIFICATIONREFERENCE($,'23-31 25 11 15','Urinal Partitions',#6935,$,$); +#6939=IFCCLASSIFICATIONREFERENCE($,'23-31 25 11 17','Shower Partitions',#6935,$,$); +#6940=IFCCLASSIFICATIONREFERENCE($,'23-31 25 13','Bathroom Cabinets',#6934,$,$); +#6941=IFCCLASSIFICATIONREFERENCE($,'23-31 25 15','Hand Dryers',#6934,$,$); +#6942=IFCCLASSIFICATIONREFERENCE($,'23-31 25 17','Hair Dryers',#6934,$,$); +#6943=IFCCLASSIFICATIONREFERENCE($,'23-31 25 19','Restroom Paper Towel Accessories',#6934,$,$); +#6944=IFCCLASSIFICATIONREFERENCE($,'23-31 25 19 11','Paper Towel Dispensers',#6943,$,$); +#6945=IFCCLASSIFICATIONREFERENCE($,'23-31 25 19 13','Paper Towel Dispenser With Disposal Units',#6943,$,$); +#6946=IFCCLASSIFICATIONREFERENCE($,'23-31 25 21','Toilet Paper Dispensers',#6934,$,$); +#6947=IFCCLASSIFICATIONREFERENCE($,'23-31 25 23','Feminine Hygiene Components',#6934,$,$); +#6948=IFCCLASSIFICATIONREFERENCE($,'23-31 25 23 11','Sanitary Napkin Dispensers',#6947,$,$); +#6949=IFCCLASSIFICATIONREFERENCE($,'23-31 25 23 13','Sanitary Napkin Dispenser With Disposal Units',#6947,$,$); +#6950=IFCCLASSIFICATIONREFERENCE($,'23-31 25 23 15','Tampon Dispensers',#6947,$,$); +#6951=IFCCLASSIFICATIONREFERENCE($,'23-31 25 23 17','Tampon Dispenser With Disposal Units',#6947,$,$); +#6952=IFCCLASSIFICATIONREFERENCE($,'23-31 25 23 19','Combination Sanitary Napkin and Tampon Dispensers',#6947,$,$); +#6953=IFCCLASSIFICATIONREFERENCE($,'23-31 25 23 21','Combination Sanitary Napkin and Tampon Dispenser With Disposal Units',#6947,$,$); +#6954=IFCCLASSIFICATIONREFERENCE($,'23-31 25 25','Towel Bars',#6934,$,$); +#6955=IFCCLASSIFICATIONREFERENCE($,'23-31 25 25 11','Electric Heated Towel Bars',#6954,$,$); +#6956=IFCCLASSIFICATIONREFERENCE($,'23-31 25 25 13','Water Heated Towel Bars',#6954,$,$); +#6957=IFCCLASSIFICATIONREFERENCE($,'23-31 25 27','Robe Hooks',#6934,$,$); +#6958=IFCCLASSIFICATIONREFERENCE($,'23-31 25 29','Restroom Hand Soap Components',#6934,$,$); +#6959=IFCCLASSIFICATIONREFERENCE($,'23-31 25 29 11','Hand Soap Holders',#6958,$,$); +#6960=IFCCLASSIFICATIONREFERENCE($,'23-31 25 29 13','Hand Soap Dispensers',#6958,$,$); +#6961=IFCCLASSIFICATIONREFERENCE($,'23-31 25 31','Diaper Changing Units',#6934,$,$); +#6962=IFCCLASSIFICATIONREFERENCE($,'23-31 25 33','Bathroom Deodorizers',#6934,$,$); +#6963=IFCCLASSIFICATIONREFERENCE($,'23-31 27 00','Floor Drains',#6849,$,$); +#6964=IFCCLASSIFICATIONREFERENCE($,'23-31 27 11','Floor Drain Plugs',#6963,$,$); +#6965=IFCCLASSIFICATIONREFERENCE($,'23-31 27 13','Floor Drain Plug Chains',#6963,$,$); +#6966=IFCCLASSIFICATIONREFERENCE($,'23-31 27 15','Floor Drain Covers',#6963,$,$); +#6967=IFCCLASSIFICATIONREFERENCE($,'23-31 29 00','Hot Water Heaters',#6849,$,$); +#6968=IFCCLASSIFICATIONREFERENCE($,'23-31 29 11','Instantaneous Hot Water Heaters',#6967,$,$); +#6969=IFCCLASSIFICATIONREFERENCE($,'23-31 29 11 11','Electric Instantaneous Hot Water Heaters',#6968,$,$); +#6970=IFCCLASSIFICATIONREFERENCE($,'23-31 29 11 13','Gas Instantaneous Hot Water Heaters',#6968,$,$); +#6971=IFCCLASSIFICATIONREFERENCE($,'23-31 29 13','Hot Water Tank Heaters',#6967,$,$); +#6972=IFCCLASSIFICATIONREFERENCE($,'23-31 29 13 11','Hot Water Tank Electric Heaters',#6971,$,$); +#6973=IFCCLASSIFICATIONREFERENCE($,'23-31 29 13 13','Hot Water Tank Gas Heaters',#6971,$,$); +#6974=IFCCLASSIFICATIONREFERENCE($,'23-31 29 13 15','Hot Water Tank Steam Heaters',#6971,$,$); +#6975=IFCCLASSIFICATIONREFERENCE($,'23-31 29 13 17','Hot Water Tank Fuel Oil Heaters',#6971,$,$); +#6976=IFCCLASSIFICATIONREFERENCE($,'23-31 31 00','Drinking Fountains',#6849,$,$); +#6977=IFCCLASSIFICATIONREFERENCE($,'23-31 31 11','Drinking Fountain With Coolers',#6976,$,$); +#6978=IFCCLASSIFICATIONREFERENCE($,'23-31 31 13','Drinking Fountains With Direct Expansion Cooling',#6976,$,$); +#6979=IFCCLASSIFICATIONREFERENCE($,'23-31 33 00','Complete Sanitary Suites',#6849,$,$); +#6980=IFCCLASSIFICATIONREFERENCE($,'23-31 33 11','Complete Bathroom Suites',#6979,$,$); +#6981=IFCCLASSIFICATIONREFERENCE($,'23-31 35 00','Plumbing Tubing',#6849,$,$); +#6982=IFCCLASSIFICATIONREFERENCE($,'23-31 35 11','Tubing Reducers',#6981,$,$); +#6983=IFCCLASSIFICATIONREFERENCE($,'23-31 35 13','Tubing Couplings',#6981,$,$); +#6984=IFCCLASSIFICATIONREFERENCE($,'23-31 35 15','Tubing Elbows',#6981,$,$); +#6985=IFCCLASSIFICATIONREFERENCE($,'23-31 35 17','Tubing Plugs',#6981,$,$); +#6986=IFCCLASSIFICATIONREFERENCE($,'23-31 35 19','Tubing Tees',#6981,$,$); +#6987=IFCCLASSIFICATIONREFERENCE($,'23-33 00 00','HVAC Specific Products and Equipment',#1606,$,$); +#6988=IFCCLASSIFICATIONREFERENCE($,'23-33 11 00','Commercial Boilers',#6987,$,$); +#6989=IFCCLASSIFICATIONREFERENCE($,'23-33 11 11','Boiler Controls',#6988,$,$); +#6990=IFCCLASSIFICATIONREFERENCE($,'23-33 11 11 11','Boiler Control Panels',#6989,$,$); +#6991=IFCCLASSIFICATIONREFERENCE($,'23-33 11 11 13','Boiler Burner Controls',#6989,$,$); +#6992=IFCCLASSIFICATIONREFERENCE($,'23-33 11 13','Condensing Boilers',#6988,$,$); +#6993=IFCCLASSIFICATIONREFERENCE($,'23-33 11 15','Fire Tube Boilers',#6988,$,$); +#6994=IFCCLASSIFICATIONREFERENCE($,'23-33 11 15 11','High Pressure Steam Fire Tube Boilers',#6993,$,$); +#6995=IFCCLASSIFICATIONREFERENCE($,'23-33 11 15 13','High Temperature Hot Water Fire Tube Boilers',#6993,$,$); +#6996=IFCCLASSIFICATIONREFERENCE($,'23-33 11 15 15','Low Pressure Steam Fire Tube Boilers',#6993,$,$); +#6997=IFCCLASSIFICATIONREFERENCE($,'23-33 11 15 17','Low Temperature Hot Water Fire Tube Boilers',#6993,$,$); +#6998=IFCCLASSIFICATIONREFERENCE($,'23-33 11 17','Flexible Tube Boilers',#6988,$,$); +#6999=IFCCLASSIFICATIONREFERENCE($,'23-33 11 17 11','High Pressure Steam Flexible Tube Boilers',#6998,$,$); +#7000=IFCCLASSIFICATIONREFERENCE($,'23-33 11 17 13','High Temperature Hot Water Flexible Tube Boilers',#6998,$,$); +#7001=IFCCLASSIFICATIONREFERENCE($,'23-33 11 17 15','Low Pressure Steam Flexible Tube Boilers',#6998,$,$); +#7002=IFCCLASSIFICATIONREFERENCE($,'23-33 11 17 17','Low Temperature Hot Water Flexible Tube Boilers',#6998,$,$); +#7003=IFCCLASSIFICATIONREFERENCE($,'23-33 11 19','Sectionalized Cast Iron Boilers',#6988,$,$); +#7004=IFCCLASSIFICATIONREFERENCE($,'23-33 11 19 11','Low Pressure Steam Sectionalized Cast Iron Boilers',#7003,$,$); +#7005=IFCCLASSIFICATIONREFERENCE($,'23-33 11 19 13','Low Temperature Hot Water Sectionalized Cast Iron Boilers',#7003,$,$); +#7006=IFCCLASSIFICATIONREFERENCE($,'23-33 11 21','Water Tube Boilers',#6988,$,$); +#7007=IFCCLASSIFICATIONREFERENCE($,'23-33 11 21 11','High Pressure Steam Water Tube Boilers',#7006,$,$); +#7008=IFCCLASSIFICATIONREFERENCE($,'23-33 11 21 13','High Temperature Hot Water Tube Boilers',#7006,$,$); +#7009=IFCCLASSIFICATIONREFERENCE($,'23-33 11 21 15','Low Pressure Steam Water Water Tube Boilers',#7006,$,$); +#7010=IFCCLASSIFICATIONREFERENCE($,'23-33 11 21 17','Low Temperature Hot Water Water Tube Boilers',#7006,$,$); +#7011=IFCCLASSIFICATIONREFERENCE($,'23-33 11 22','Electric Boilers',#6988,$,$); +#7012=IFCCLASSIFICATIONREFERENCE($,'23-33 11 23','Boiler Components',#6988,$,$); +#7013=IFCCLASSIFICATIONREFERENCE($,'23-33 11 23 11','Boiler Joint Fillers and Sealants',#7012,$,$); +#7014=IFCCLASSIFICATIONREFERENCE($,'23-33 11 23 13','Boiler Fuel Burners',#7012,$,$); +#7015=IFCCLASSIFICATIONREFERENCE($,'23-33 11 23 15','Boiler Fuel Oil Filters',#7012,$,$); +#7016=IFCCLASSIFICATIONREFERENCE($,'23-33 11 23 17','Boiler Nozzles',#7012,$,$); +#7017=IFCCLASSIFICATIONREFERENCE($,'23-33 11 23 19','Boiler Induction Blowers',#7012,$,$); +#7018=IFCCLASSIFICATIONREFERENCE($,'23-33 11 23 21','Boiler Fuel Gas Heat Recovery Devices',#7012,$,$); +#7019=IFCCLASSIFICATIONREFERENCE($,'23-33 11 23 23','Boiler Draft Fans',#7012,$,$); +#7020=IFCCLASSIFICATIONREFERENCE($,'23-33 13 00','Furnaces',#6987,$,$); +#7021=IFCCLASSIFICATIONREFERENCE($,'23-33 13 11','Furnace Controls',#7020,$,$); +#7022=IFCCLASSIFICATIONREFERENCE($,'23-33 13 11 11','Furnace Control Panels',#7021,$,$); +#7023=IFCCLASSIFICATIONREFERENCE($,'23-33 13 11 13','Furnace Burner Controls',#7021,$,$); +#7024=IFCCLASSIFICATIONREFERENCE($,'23-33 13 13','Coal Fired Furnaces',#7020,$,$); +#7025=IFCCLASSIFICATIONREFERENCE($,'23-33 13 15','Electric Resistance Furnaces',#7020,$,$); +#7026=IFCCLASSIFICATIONREFERENCE($,'23-33 13 17','Natural Gas Fired Furnaces',#7020,$,$); +#7027=IFCCLASSIFICATIONREFERENCE($,'23-33 13 19','Gasoline Fired Furnaces',#7020,$,$); +#7028=IFCCLASSIFICATIONREFERENCE($,'23-33 13 21','Fuel Oil Fired Furnaces',#7020,$,$); +#7029=IFCCLASSIFICATIONREFERENCE($,'23-33 13 23','Oil Fired Furnaces',#7020,$,$); +#7030=IFCCLASSIFICATIONREFERENCE($,'23-33 13 25','Propane Fired Furnaces',#7020,$,$); +#7031=IFCCLASSIFICATIONREFERENCE($,'23-33 13 27','Furnace Components',#7020,$,$); +#7032=IFCCLASSIFICATIONREFERENCE($,'23-33 13 27 11','Furnace Joint Fillers and Sealants',#7031,$,$); +#7033=IFCCLASSIFICATIONREFERENCE($,'23-33 13 27 13','Furnace Fuel Burners',#7031,$,$); +#7034=IFCCLASSIFICATIONREFERENCE($,'23-33 13 27 15','Furnace Fuel Oil Filters',#7031,$,$); +#7035=IFCCLASSIFICATIONREFERENCE($,'23-33 13 27 17','Furnace Nozzles',#7031,$,$); +#7036=IFCCLASSIFICATIONREFERENCE($,'23-33 13 27 19','Furnace Fuel Gas Heat Recovery Devices',#7031,$,$); +#7037=IFCCLASSIFICATIONREFERENCE($,'23-33 15 00','HVAC Heating Units',#6987,$,$); +#7038=IFCCLASSIFICATIONREFERENCE($,'23-33 15 11','Propane HVAC Heaters',#7037,$,$); +#7039=IFCCLASSIFICATIONREFERENCE($,'23-33 15 11 11','Indoor Propane HVAC Heaters',#7038,$,$); +#7040=IFCCLASSIFICATIONREFERENCE($,'23-33 15 11 13','Outdoor Propane HVAC Heaters',#7038,$,$); +#7041=IFCCLASSIFICATIONREFERENCE($,'23-33 15 13','Heating Stoves',#7037,$,$); +#7042=IFCCLASSIFICATIONREFERENCE($,'23-33 15 13 11','Cast Iron Heating Stoves',#7041,$,$); +#7043=IFCCLASSIFICATIONREFERENCE($,'23-33 15 13 13','Stone Heating Stoves',#7041,$,$); +#7044=IFCCLASSIFICATIONREFERENCE($,'23-33 15 13 15','Welded Steel Heating Stoves',#7041,$,$); +#7045=IFCCLASSIFICATIONREFERENCE($,'23-33 15 13 17','Heating Stove Components',#7041,$,$); +#7046=IFCCLASSIFICATIONREFERENCE($,'23-33 15 13 17 11','Heating Stove Fenders',#7045,$,$); +#7047=IFCCLASSIFICATIONREFERENCE($,'23-33 15 13 17 13','Heating Stove Hoods',#7045,$,$); +#7048=IFCCLASSIFICATIONREFERENCE($,'23-33 15 13 17 15','Heating Stove Pipes',#7045,$,$); +#7049=IFCCLASSIFICATIONREFERENCE($,'23-33 15 15','Specialized Surface Heating Products',#7037,$,$); +#7050=IFCCLASSIFICATIONREFERENCE($,'23-33 15 15 11','Heating Sheets',#7049,$,$); +#7051=IFCCLASSIFICATIONREFERENCE($,'23-33 15 15 11 11','Heating Sheets for Walls',#7050,$,$); +#7052=IFCCLASSIFICATIONREFERENCE($,'23-33 15 15 11 13','Heating Sheets for Ceilings',#7050,$,$); +#7053=IFCCLASSIFICATIONREFERENCE($,'23-33 15 15 11 15','Embedded Electric Heating Sheets',#7050,$,$); +#7054=IFCCLASSIFICATIONREFERENCE($,'23-33 15 15 11 17','Heating Sheets for Glazing',#7050,$,$); +#7055=IFCCLASSIFICATIONREFERENCE($,'23-33 15 15 13','Heating Cables',#7049,$,$); +#7056=IFCCLASSIFICATIONREFERENCE($,'23-33 15 15 15','Pipe Heat Tape',#7049,$,$); +#7057=IFCCLASSIFICATIONREFERENCE($,'23-33 15 15 17','Cable Heat Trace',#7049,$,$); +#7058=IFCCLASSIFICATIONREFERENCE($,'23-33 15 15 19','Heated Ceiling Panels',#7049,$,$); +#7059=IFCCLASSIFICATIONREFERENCE($,'23-33 15 15 21','Pipe Heat Tracing',#7049,$,$); +#7060=IFCCLASSIFICATIONREFERENCE($,'23-33 15 17','Fuel Fired HVAC Heaters',#7037,$,$); +#7061=IFCCLASSIFICATIONREFERENCE($,'23-33 15 17 11','Fuel Fired HVAC Duct Heaters',#7060,$,$); +#7062=IFCCLASSIFICATIONREFERENCE($,'23-33 15 17 13','Fuel Fired HVAC Radiant Heaters',#7060,$,$); +#7063=IFCCLASSIFICATIONREFERENCE($,'23-33 15 17 15','Fuel Fired HVAC Unit Heaters',#7060,$,$); +#7064=IFCCLASSIFICATIONREFERENCE($,'23-33 15 17 17','Fuel Fired HVAC Air Heaters',#7060,$,$); +#7065=IFCCLASSIFICATIONREFERENCE($,'23-33 15 19','Forced Air Fuel Fired HVAC Heaters',#7037,$,$); +#7066=IFCCLASSIFICATIONREFERENCE($,'23-33 15 19 11','Forced Air Fuel Fired HVAC Duct Heaters',#7065,$,$); +#7067=IFCCLASSIFICATIONREFERENCE($,'23-33 15 19 13','Forced Air Fuel Fired HVAC Radiant Heaters',#7065,$,$); +#7068=IFCCLASSIFICATIONREFERENCE($,'23-33 15 19 15','Forced Air Fuel Fired HVAC Unit Heaters',#7065,$,$); +#7069=IFCCLASSIFICATIONREFERENCE($,'23-33 15 19 17','Forced Air Fuel Fired HVAC Air Heaters',#7065,$,$); +#7070=IFCCLASSIFICATIONREFERENCE($,'23-33 15 21','Hydronic HVAC Heaters',#7037,$,$); +#7071=IFCCLASSIFICATIONREFERENCE($,'23-33 15 21 11','Cast Iron Radiators',#7070,$,$); +#7072=IFCCLASSIFICATIONREFERENCE($,'23-33 15 21 13','Finned Tube Radiators',#7070,$,$); +#7073=IFCCLASSIFICATIONREFERENCE($,'23-33 15 21 15','Plate Radiators',#7070,$,$); +#7074=IFCCLASSIFICATIONREFERENCE($,'23-33 15 21 17','Radiation Heating Panels',#7070,$,$); +#7075=IFCCLASSIFICATIONREFERENCE($,'23-33 15 23','Forced Air Hydronic HVAC Heaters',#7037,$,$); +#7076=IFCCLASSIFICATIONREFERENCE($,'23-33 15 23 11','Forced Air Cast Iron Radiators',#7075,$,$); +#7077=IFCCLASSIFICATIONREFERENCE($,'23-33 15 23 13','Forced Air Finned Tube Radiators',#7075,$,$); +#7078=IFCCLASSIFICATIONREFERENCE($,'23-33 15 23 15','Forced Air Plate Radiators',#7075,$,$); +#7079=IFCCLASSIFICATIONREFERENCE($,'23-33 15 23 17','Forced Air Radiation Heating Panels',#7075,$,$); +#7080=IFCCLASSIFICATIONREFERENCE($,'23-33 15 25','Electric HVAC Heaters',#7037,$,$); +#7081=IFCCLASSIFICATIONREFERENCE($,'23-33 15 25 11','Halogen Electric HVAC Heaters',#7080,$,$); +#7082=IFCCLASSIFICATIONREFERENCE($,'23-33 15 25 13','Infrared Plate HVAC Heaters',#7080,$,$); +#7083=IFCCLASSIFICATIONREFERENCE($,'23-33 15 25 15','Ultraviolet HVAC Heaters',#7080,$,$); +#7084=IFCCLASSIFICATIONREFERENCE($,'23-33 15 25 17','Electric HVAC Resistive Unit Heaters',#7080,$,$); +#7085=IFCCLASSIFICATIONREFERENCE($,'23-33 15 27','Forced Air Electric HVAC Heaters',#7037,$,$); +#7086=IFCCLASSIFICATIONREFERENCE($,'23-33 15 27 11','Forced Air Halogen Electric HVAC Heaters',#7085,$,$); +#7087=IFCCLASSIFICATIONREFERENCE($,'23-33 15 27 13','Forced Air Infrared Plate HVAC Heaters',#7085,$,$); +#7088=IFCCLASSIFICATIONREFERENCE($,'23-33 15 27 15','Forced Air Ultraviolet HVAC Heaters',#7085,$,$); +#7089=IFCCLASSIFICATIONREFERENCE($,'23-33 15 27 17','Forced Air Electric HVAC Resitive Unit Heaters',#7085,$,$); +#7090=IFCCLASSIFICATIONREFERENCE($,'23-33 15 29','HVAC Steam Hot Water Converters',#7037,$,$); +#7091=IFCCLASSIFICATIONREFERENCE($,'23-33 17 00','Heat Pumps',#6987,$,$); +#7092=IFCCLASSIFICATIONREFERENCE($,'23-33 17 11','Packaged Heat Pumps',#7091,$,$); +#7093=IFCCLASSIFICATIONREFERENCE($,'23-33 17 11 11','Air Source Packaged Heat Pumps',#7092,$,$); +#7094=IFCCLASSIFICATIONREFERENCE($,'23-33 17 11 13','Water Source Packaged Heat Pumps',#7092,$,$); +#7095=IFCCLASSIFICATIONREFERENCE($,'23-33 17 13','Split System Heat Pumps',#7091,$,$); +#7096=IFCCLASSIFICATIONREFERENCE($,'23-33 17 13 11','Air Source Split System Heat Pumps',#7095,$,$); +#7097=IFCCLASSIFICATIONREFERENCE($,'23-33 17 13 13','Water Source Split System Heat Pumps',#7095,$,$); +#7098=IFCCLASSIFICATIONREFERENCE($,'23-33 19 00','Cooling and Freeze Components',#6987,$,$); +#7099=IFCCLASSIFICATIONREFERENCE($,'23-33 19 11','Cooling Freeze Plant Accessories',#7098,$,$); +#7100=IFCCLASSIFICATIONREFERENCE($,'23-33 19 11 11','Refrigerant Liquid',#7099,$,$); +#7101=IFCCLASSIFICATIONREFERENCE($,'23-33 21 00','Chillers',#6987,$,$); +#7102=IFCCLASSIFICATIONREFERENCE($,'23-33 21 11','Absorption Chillers',#7101,$,$); +#7103=IFCCLASSIFICATIONREFERENCE($,'23-33 21 11 11','Direct Fired Absorption Chillers',#7102,$,$); +#7104=IFCCLASSIFICATIONREFERENCE($,'23-33 21 11 13','Steam Absorption Chillers',#7102,$,$); +#7105=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13','Chillers',#7101,$,$); +#7106=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 11','Central Package Unit Chillers',#7105,$,$); +#7107=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 13','Centrifugal Chillers',#7105,$,$); +#7108=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 13 11','Packaged Centrifugal Chillers',#7107,$,$); +#7109=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 13 13','Split System Centrifugal Chillers',#7107,$,$); +#7110=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 15','Reciprocating Chillers',#7105,$,$); +#7111=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 15 11','Packaged Reciprocating Chillers',#7110,$,$); +#7112=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 15 13','Split System Reciprocating Chillers',#7110,$,$); +#7113=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 17','Rotary Chillers',#7105,$,$); +#7114=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 17 11','Packaged Rotary Chillers',#7113,$,$); +#7115=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 17 13','Split System Rotary Chillers',#7113,$,$); +#7116=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 19','Rotary Screw Chillers',#7105,$,$); +#7117=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 19 11','Packaged Rotary Screw Chillers',#7116,$,$); +#7118=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 19 13','Split System Rotary Screw Chillers',#7116,$,$); +#7119=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 21','Screw Chillers',#7105,$,$); +#7120=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 21 11','Packaged Screw Chillers',#7119,$,$); +#7121=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 21 13','Split System Screw Chillers',#7119,$,$); +#7122=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 23','Scroll Chillers',#7105,$,$); +#7123=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 23 11','Packaged Scroll Chillers',#7122,$,$); +#7124=IFCCLASSIFICATIONREFERENCE($,'23-33 21 13 23 13','Split System Scroll Chillers',#7122,$,$); +#7125=IFCCLASSIFICATIONREFERENCE($,'23-33 23 00','Cooling Towers',#6987,$,$); +#7126=IFCCLASSIFICATIONREFERENCE($,'23-33 23 11','Mechanical Draft Cooling Towers',#7125,$,$); +#7127=IFCCLASSIFICATIONREFERENCE($,'23-33 23 13','Natural Draft Cooling Towers',#7125,$,$); +#7128=IFCCLASSIFICATIONREFERENCE($,'23-33 23 15','Cooling Ponds',#7125,$,$); +#7129=IFCCLASSIFICATIONREFERENCE($,'23-33 25 00','Air Handling Units',#6987,$,$); +#7130=IFCCLASSIFICATIONREFERENCE($,'23-33 25 11','Built Up Air Handling Units',#7129,$,$); +#7131=IFCCLASSIFICATIONREFERENCE($,'23-33 25 11 11','Built Up Indoor Air Handling Units',#7130,$,$); +#7132=IFCCLASSIFICATIONREFERENCE($,'23-33 25 11 13','Built Up Rooftop Air Handling Units',#7130,$,$); +#7133=IFCCLASSIFICATIONREFERENCE($,'23-33 25 13','Customized Air Handling Units',#7129,$,$); +#7134=IFCCLASSIFICATIONREFERENCE($,'23-33 25 13 11','Customized Indoor Air Handling Units',#7133,$,$); +#7135=IFCCLASSIFICATIONREFERENCE($,'23-33 25 13 13','Customized Rooftop Air Handling Units',#7133,$,$); +#7136=IFCCLASSIFICATIONREFERENCE($,'23-33 25 15','Heating and Ventilating Units',#7129,$,$); +#7137=IFCCLASSIFICATIONREFERENCE($,'23-33 25 17','Modular Air Handling Units',#7129,$,$); +#7138=IFCCLASSIFICATIONREFERENCE($,'23-33 25 17 11','Modular Indoor Air Handling Units',#7137,$,$); +#7139=IFCCLASSIFICATIONREFERENCE($,'23-33 25 17 13','Modular Rooftop Air Handling Units',#7137,$,$); +#7140=IFCCLASSIFICATIONREFERENCE($,'23-33 25 19','Pre Fabricated Air Handling Units',#7129,$,$); +#7141=IFCCLASSIFICATIONREFERENCE($,'23-33 27 00','Air Humidity Control Equipment',#6987,$,$); +#7142=IFCCLASSIFICATIONREFERENCE($,'23-33 27 11','Air Washers',#7141,$,$); +#7143=IFCCLASSIFICATIONREFERENCE($,'23-33 27 11 11','Convection Air Washers',#7142,$,$); +#7144=IFCCLASSIFICATIONREFERENCE($,'23-33 27 11 13','Evaporative Air Washers',#7142,$,$); +#7145=IFCCLASSIFICATIONREFERENCE($,'23-33 27 13','Dehumidifiers',#7141,$,$); +#7146=IFCCLASSIFICATIONREFERENCE($,'23-33 27 13 11','Dehumidifiers',#7145,$,$); +#7147=IFCCLASSIFICATIONREFERENCE($,'23-33 27 13 11 11','Swimming Pool Dehumidification Units',#7146,$,$); +#7148=IFCCLASSIFICATIONREFERENCE($,'23-33 27 13 13','Permanently Installed Dehumidifiers',#7145,$,$); +#7149=IFCCLASSIFICATIONREFERENCE($,'23-33 27 13 15','Portable Dehumidifiers',#7145,$,$); +#7150=IFCCLASSIFICATIONREFERENCE($,'23-33 27 15','Air Humidifiers',#7141,$,$); +#7151=IFCCLASSIFICATIONREFERENCE($,'23-33 27 17','Vaporizers',#7141,$,$); +#7152=IFCCLASSIFICATIONREFERENCE($,'23-33 29 00','HVAC Dampers',#6987,$,$); +#7153=IFCCLASSIFICATIONREFERENCE($,'23-33 29 11','3 Way Diverter Dampers',#7152,$,$); +#7154=IFCCLASSIFICATIONREFERENCE($,'23-33 29 13','Backdraft Dampers',#7152,$,$); +#7155=IFCCLASSIFICATIONREFERENCE($,'23-33 29 13 11','Opposed Blade Backdraft Dampers',#7154,$,$); +#7156=IFCCLASSIFICATIONREFERENCE($,'23-33 29 13 11 11','Spring Loaded Opposed Blade Backdraft Dampers',#7155,$,$); +#7157=IFCCLASSIFICATIONREFERENCE($,'23-33 29 13 11 13','Counter Weight Balanced Opposed Blade Backdraft Dampers',#7155,$,$); +#7158=IFCCLASSIFICATIONREFERENCE($,'23-33 29 13 13','Parallel Backdraft Dampers',#7154,$,$); +#7159=IFCCLASSIFICATIONREFERENCE($,'23-33 29 13 13 11','Spring Loaded Parallel Backdraft Dampers',#7158,$,$); +#7160=IFCCLASSIFICATIONREFERENCE($,'23-33 29 13 13 13','Counter Weight Balanced Parallel Backdraft Dampers',#7158,$,$); +#7161=IFCCLASSIFICATIONREFERENCE($,'23-33 29 15','Bi Plane Dampers',#7152,$,$); +#7162=IFCCLASSIFICATIONREFERENCE($,'23-33 29 17','Butterfly Dampers',#7152,$,$); +#7163=IFCCLASSIFICATIONREFERENCE($,'23-33 29 17 11','Automatically Control Butterfly Dampers',#7162,$,$); +#7164=IFCCLASSIFICATIONREFERENCE($,'23-33 29 17 13','Manual Butterfly Dampers',#7162,$,$); +#7165=IFCCLASSIFICATIONREFERENCE($,'23-33 29 19','Dampers',#7152,$,$); +#7166=IFCCLASSIFICATIONREFERENCE($,'23-33 29 19 11','Automatically Control Dampers',#7165,$,$); +#7167=IFCCLASSIFICATIONREFERENCE($,'23-33 29 19 13','Manual Dampers',#7165,$,$); +#7168=IFCCLASSIFICATIONREFERENCE($,'23-33 29 21','Diffuser Firestop Flaps',#7152,$,$); +#7169=IFCCLASSIFICATIONREFERENCE($,'23-33 29 23','Fire Dampers',#7152,$,$); +#7170=IFCCLASSIFICATIONREFERENCE($,'23-33 29 23 11','Manual Fire Dampers',#7169,$,$); +#7171=IFCCLASSIFICATIONREFERENCE($,'23-33 29 23 13','Automatic Fire Dampers',#7169,$,$); +#7172=IFCCLASSIFICATIONREFERENCE($,'23-33 29 25','Smoke Dampers',#7152,$,$); +#7173=IFCCLASSIFICATIONREFERENCE($,'23-33 29 25 11','Manual Smoke Dampers',#7172,$,$); +#7174=IFCCLASSIFICATIONREFERENCE($,'23-33 29 25 13','Automatic Smoke Dampers',#7172,$,$); +#7175=IFCCLASSIFICATIONREFERENCE($,'23-33 29 27','Non Return Dampers',#7152,$,$); +#7176=IFCCLASSIFICATIONREFERENCE($,'23-33 29 29','Guillotine Dampers',#7152,$,$); +#7177=IFCCLASSIFICATIONREFERENCE($,'23-33 29 31','Louvre Dampers',#7152,$,$); +#7178=IFCCLASSIFICATIONREFERENCE($,'23-33 29 31 11','Louvre Dampers with Opposed Blade Motion',#7177,$,$); +#7179=IFCCLASSIFICATIONREFERENCE($,'23-33 29 33','Movable Blade Wall Louvers',#7152,$,$); +#7180=IFCCLASSIFICATIONREFERENCE($,'23-33 29 33 11','Double Panel Wall Louvers',#7179,$,$); +#7181=IFCCLASSIFICATIONREFERENCE($,'23-33 29 35','Static Pressure Regulating Dampers',#7152,$,$); +#7182=IFCCLASSIFICATIONREFERENCE($,'23-33 29 37','Volume Control Dampers',#7152,$,$); +#7183=IFCCLASSIFICATIONREFERENCE($,'23-33 29 37 11','Opposed Blade Volume Control Dampers',#7182,$,$); +#7184=IFCCLASSIFICATIONREFERENCE($,'23-33 29 37 11 11','Manual Opposed Blade Volume Control Dampers',#7183,$,$); +#7185=IFCCLASSIFICATIONREFERENCE($,'23-33 29 37 11 13','Automatic Opposed Blade Volume Control Dampers',#7183,$,$); +#7186=IFCCLASSIFICATIONREFERENCE($,'23-33 29 37 13','Parallel Volume Control Dampers',#7182,$,$); +#7187=IFCCLASSIFICATIONREFERENCE($,'23-33 29 37 13 11','Manual Parallel Volume Control Dampers',#7186,$,$); +#7188=IFCCLASSIFICATIONREFERENCE($,'23-33 29 37 13 13','Automatic Parallel Volume Control Dampers',#7186,$,$); +#7189=IFCCLASSIFICATIONREFERENCE($,'23-33 29 39','Fire Shutters for Air Ductwork',#7152,$,$); +#7190=IFCCLASSIFICATIONREFERENCE($,'23-33 31 00','Air Circulators',#6987,$,$); +#7191=IFCCLASSIFICATIONREFERENCE($,'23-33 31 11','Air Curtains',#7190,$,$); +#7192=IFCCLASSIFICATIONREFERENCE($,'23-33 31 11 11','Heated Air Curtains',#7191,$,$); +#7193=IFCCLASSIFICATIONREFERENCE($,'23-33 31 11 13','Non Heated Air Curtains',#7191,$,$); +#7194=IFCCLASSIFICATIONREFERENCE($,'23-33 31 13','Blowers',#7190,$,$); +#7195=IFCCLASSIFICATIONREFERENCE($,'23-33 31 13 11','Permanently Installed Blowers',#7194,$,$); +#7196=IFCCLASSIFICATIONREFERENCE($,'23-33 31 13 13','Portable Blowers',#7194,$,$); +#7197=IFCCLASSIFICATIONREFERENCE($,'23-33 31 15','Exhaust Hoods',#7190,$,$); +#7198=IFCCLASSIFICATIONREFERENCE($,'23-33 31 15 11','Canopy Exhaust Hoods',#7197,$,$); +#7199=IFCCLASSIFICATIONREFERENCE($,'23-33 31 15 13','Chemical Fume Hoods',#7197,$,$); +#7200=IFCCLASSIFICATIONREFERENCE($,'23-33 31 15 15','Perchloric Acid Fume Hoods',#7197,$,$); +#7201=IFCCLASSIFICATIONREFERENCE($,'23-33 31 15 17','Radio Isotope Fume Hoods',#7197,$,$); +#7202=IFCCLASSIFICATIONREFERENCE($,'23-33 31 15 19','Snorkel Exhaust Hoods',#7197,$,$); +#7203=IFCCLASSIFICATIONREFERENCE($,'23-33 31 15 21','Grease Exhaust Hoods',#7197,$,$); +#7204=IFCCLASSIFICATIONREFERENCE($,'23-33 31 17','Exhaust Hood Fire Suppression System',#7190,$,$); +#7205=IFCCLASSIFICATIONREFERENCE($,'23-33 31 17 11','Chemical Exhaust Hood Fire Suppression Systems',#7204,$,$); +#7206=IFCCLASSIFICATIONREFERENCE($,'23-33 31 17 13','Gas Exhaust Hood Fire Suppression Systems',#7204,$,$); +#7207=IFCCLASSIFICATIONREFERENCE($,'23-33 31 19','Fans',#7190,$,$); +#7208=IFCCLASSIFICATIONREFERENCE($,'23-33 31 19 11','Axial Fans',#7207,$,$); +#7209=IFCCLASSIFICATIONREFERENCE($,'23-33 31 19 11 11','Axial Plug Fans',#7208,$,$); +#7210=IFCCLASSIFICATIONREFERENCE($,'23-33 31 19 11 13','Axial Vane Fans',#7208,$,$); +#7211=IFCCLASSIFICATIONREFERENCE($,'23-33 31 19 11 15','Ceiling Fans',#7208,$,$); +#7212=IFCCLASSIFICATIONREFERENCE($,'23-33 31 19 11 17','Propeller Fans',#7208,$,$); +#7213=IFCCLASSIFICATIONREFERENCE($,'23-33 31 19 11 19','Tube Axial Fans',#7208,$,$); +#7214=IFCCLASSIFICATIONREFERENCE($,'23-33 31 19 11 21','Variable Pitch Axial Vane Fans',#7208,$,$); +#7215=IFCCLASSIFICATIONREFERENCE($,'23-33 31 19 13','Centrifugal Fans',#7207,$,$); +#7216=IFCCLASSIFICATIONREFERENCE($,'23-33 31 19 13 11','Centrifugal Plug Fans',#7215,$,$); +#7217=IFCCLASSIFICATIONREFERENCE($,'23-33 31 19 13 13','Double Inlet Centrifugal Fans',#7215,$,$); +#7218=IFCCLASSIFICATIONREFERENCE($,'23-33 31 19 13 15','Single Inlet Centrifugal Fans',#7215,$,$); +#7219=IFCCLASSIFICATIONREFERENCE($,'23-33 31 21','Power Ventilators',#7190,$,$); +#7220=IFCCLASSIFICATIONREFERENCE($,'23-33 31 21 11','Centrifugal Power Ventilators',#7219,$,$); +#7221=IFCCLASSIFICATIONREFERENCE($,'23-33 31 21 11 11','Down Blast Centrifugal Power Ventilators',#7220,$,$); +#7222=IFCCLASSIFICATIONREFERENCE($,'23-33 31 21 11 13','Up Blast Centrifugal Power Ventilators',#7220,$,$); +#7223=IFCCLASSIFICATIONREFERENCE($,'23-33 31 21 13','Propeller Power Ventilators',#7219,$,$); +#7224=IFCCLASSIFICATIONREFERENCE($,'23-33 31 21 13 11','Down Blast Propeller Power Ventilators',#7223,$,$); +#7225=IFCCLASSIFICATIONREFERENCE($,'23-33 31 21 13 13','Up Blast Propeller Power Ventilators',#7223,$,$); +#7226=IFCCLASSIFICATIONREFERENCE($,'23-33 33 00','HVAC Fan Coil Units',#6987,$,$); +#7227=IFCCLASSIFICATIONREFERENCE($,'23-33 33 11','Fan Coil Units',#7226,$,$); +#7228=IFCCLASSIFICATIONREFERENCE($,'23-33 33 11 11','Fan Coil Cooling Units',#7227,$,$); +#7229=IFCCLASSIFICATIONREFERENCE($,'23-33 33 11 11 11','2 Pipe Fan Coil Cooling Units',#7228,$,$); +#7230=IFCCLASSIFICATIONREFERENCE($,'23-33 33 11 11 13','4 Pipe Fan Coil Cooling Units',#7228,$,$); +#7231=IFCCLASSIFICATIONREFERENCE($,'23-33 33 11 13','Fan Coil Heating Units',#7227,$,$); +#7232=IFCCLASSIFICATIONREFERENCE($,'23-33 33 11 13 11','4 Pipe Fan Coil Heating Units',#7231,$,$); +#7233=IFCCLASSIFICATIONREFERENCE($,'23-33 33 11 13 13','2 Pipe Fan Coil Heating Units',#7231,$,$); +#7234=IFCCLASSIFICATIONREFERENCE($,'23-33 33 11 15','Fan Coil Heating and Cooling Units',#7227,$,$); +#7235=IFCCLASSIFICATIONREFERENCE($,'23-33 33 11 15 11','2 Pipe Fan Coil Heating and Cooling Units',#7234,$,$); +#7236=IFCCLASSIFICATIONREFERENCE($,'23-33 33 11 15 13','4 Pipe Fan Coil Heating and Cooling Units',#7234,$,$); +#7237=IFCCLASSIFICATIONREFERENCE($,'23-33 35 00','HVAC Coils',#6987,$,$); +#7238=IFCCLASSIFICATIONREFERENCE($,'23-33 35 11','HVAC Coils',#7237,$,$); +#7239=IFCCLASSIFICATIONREFERENCE($,'23-33 35 11 11','HVAC Glycol Coils',#7238,$,$); +#7240=IFCCLASSIFICATIONREFERENCE($,'23-33 35 11 13','HVAC Steam Coils',#7238,$,$); +#7241=IFCCLASSIFICATIONREFERENCE($,'23-33 35 11 15','HVAC Water Coils',#7238,$,$); +#7242=IFCCLASSIFICATIONREFERENCE($,'23-33 37 00','Refrigerant Condensing Units',#6987,$,$); +#7243=IFCCLASSIFICATIONREFERENCE($,'23-33 37 11','Packaged Refrigerant Coils and Fan Units',#7242,$,$); +#7244=IFCCLASSIFICATIONREFERENCE($,'23-33 37 13','Refrigerant Condensing Coils',#7242,$,$); +#7245=IFCCLASSIFICATIONREFERENCE($,'23-33 37 15','Refrigerant Evaporators',#7242,$,$); +#7246=IFCCLASSIFICATIONREFERENCE($,'23-33 39 00','Air Conditioning Equipment',#6987,$,$); +#7247=IFCCLASSIFICATIONREFERENCE($,'23-33 39 11','Air Conditioners',#7246,$,$); +#7248=IFCCLASSIFICATIONREFERENCE($,'23-33 39 11 11','Room Air Conditioners',#7247,$,$); +#7249=IFCCLASSIFICATIONREFERENCE($,'23-33 39 13','High Pressure Air Conditioning Units',#7246,$,$); +#7250=IFCCLASSIFICATIONREFERENCE($,'23-33 39 15','Make Up Air Units',#7246,$,$); +#7251=IFCCLASSIFICATIONREFERENCE($,'23-33 39 15 11','Make Up Air Units With Heat',#7250,$,$); +#7252=IFCCLASSIFICATIONREFERENCE($,'23-33 39 15 13','Make Up Air Units Without Heat',#7250,$,$); +#7253=IFCCLASSIFICATIONREFERENCE($,'23-33 39 17','Packaged Air Conditioners',#7246,$,$); +#7254=IFCCLASSIFICATIONREFERENCE($,'23-33 39 17 11','Dual Pack Packaged Air Conditioners',#7253,$,$); +#7255=IFCCLASSIFICATIONREFERENCE($,'23-33 39 17 11 11','Air Cooled Dual Pack Packaged Air Conditioners',#7254,$,$); +#7256=IFCCLASSIFICATIONREFERENCE($,'23-33 39 17 11 13','Water Cooled Dual Pack Packaged Air Conditioners',#7254,$,$); +#7257=IFCCLASSIFICATIONREFERENCE($,'23-33 39 17 13','Single Pack Packaged Air Conditioners',#7253,$,$); +#7258=IFCCLASSIFICATIONREFERENCE($,'23-33 39 17 13 11','Air Cooled Single Pack Packaged Air Conditioners',#7257,$,$); +#7259=IFCCLASSIFICATIONREFERENCE($,'23-33 39 17 13 13','Water Cooled Single Pack Packaged Air Conditioners',#7257,$,$); +#7260=IFCCLASSIFICATIONREFERENCE($,'23-33 39 17 13 15','Unitary Air Conditioning Equipment',#7257,$,$); +#7261=IFCCLASSIFICATIONREFERENCE($,'23-33 39 19','Packaged Terminal Air Conditioning Units',#7246,$,$); +#7262=IFCCLASSIFICATIONREFERENCE($,'23-33 39 19 11','Fixed Packaged Terminal Air Conditioners',#7261,$,$); +#7263=IFCCLASSIFICATIONREFERENCE($,'23-33 39 19 11 11','Air Cooled Fixed Packaged Terminal Air Conditioners',#7262,$,$); +#7264=IFCCLASSIFICATIONREFERENCE($,'23-33 39 19 11 13','Water Cooled Fixed Packaged Terminal Air Conditioners',#7262,$,$); +#7265=IFCCLASSIFICATIONREFERENCE($,'23-33 39 19 13','Portable Packaged Terminal Air Conditioners',#7261,$,$); +#7266=IFCCLASSIFICATIONREFERENCE($,'23-33 39 19 13 11','Air Cooled Portable Packaged Terminal Air Conditioners',#7265,$,$); +#7267=IFCCLASSIFICATIONREFERENCE($,'23-33 39 19 13 13','Water Cooled Portable Packaged Terminal Air Conditioners',#7265,$,$); +#7268=IFCCLASSIFICATIONREFERENCE($,'23-33 39 19 15','Window Packaged Terminal Air Conditioners',#7261,$,$); +#7269=IFCCLASSIFICATIONREFERENCE($,'23-33 39 19 15 11','Air Cooled Window Packaged Terminal Air Conditioners',#7268,$,$); +#7270=IFCCLASSIFICATIONREFERENCE($,'23-33 39 19 15 13','Water Cooled Window Packaged Terminal Air Conditioners',#7268,$,$); +#7271=IFCCLASSIFICATIONREFERENCE($,'23-33 39 21','Split System Air Conditioning Units',#7246,$,$); +#7272=IFCCLASSIFICATIONREFERENCE($,'23-33 41 00','HVAC Air Terminals',#6987,$,$); +#7273=IFCCLASSIFICATIONREFERENCE($,'23-33 41 11','Fan Powered Terminal Air Units',#7272,$,$); +#7274=IFCCLASSIFICATIONREFERENCE($,'23-33 41 11 11','Mixing Fan Powered Terminal Air Units',#7273,$,$); +#7275=IFCCLASSIFICATIONREFERENCE($,'23-33 41 11 11 11','Single Duct Mixing Fan Powered Terminal Air Units',#7274,$,$); +#7276=IFCCLASSIFICATIONREFERENCE($,'23-33 41 11 11 13','Dual Duct Mixing Fan Powered Terminal Air Units',#7274,$,$); +#7277=IFCCLASSIFICATIONREFERENCE($,'23-33 41 11 13','Non Mixing Fan Powered Terminal Air Units',#7273,$,$); +#7278=IFCCLASSIFICATIONREFERENCE($,'23-33 41 11 13 11','Single Duct Mixing Fan Powered Terminal Air Units',#7277,$,$); +#7279=IFCCLASSIFICATIONREFERENCE($,'23-33 41 11 13 13','Dual Duct Mixing Fan Powered Terminal Air Units',#7277,$,$); +#7280=IFCCLASSIFICATIONREFERENCE($,'23-33 41 13','Induction Terminal Air Units',#7272,$,$); +#7281=IFCCLASSIFICATIONREFERENCE($,'23-33 41 13 11','Constant Volume Air Induction Terminal Air Units',#7280,$,$); +#7282=IFCCLASSIFICATIONREFERENCE($,'23-33 41 13 11 11','Single Duct Constant Volume Air Induction Terminal Air Units',#7281,$,$); +#7283=IFCCLASSIFICATIONREFERENCE($,'23-33 41 13 11 13','Dual Duct Constant Volume Air Induction Terminal Air Units',#7281,$,$); +#7284=IFCCLASSIFICATIONREFERENCE($,'23-33 41 13 13','Variable Air Volume Induction Terminal Air Units',#7280,$,$); +#7285=IFCCLASSIFICATIONREFERENCE($,'23-33 41 13 13 11','Single Duct Variable Air Volume Induction Terminal Air Units',#7284,$,$); +#7286=IFCCLASSIFICATIONREFERENCE($,'23-33 41 13 13 13','Dual Duct Variable Air Volume Induction Terminal Air Units',#7284,$,$); +#7287=IFCCLASSIFICATIONREFERENCE($,'23-33 41 15','HVAC Mixing Boxes',#7272,$,$); +#7288=IFCCLASSIFICATIONREFERENCE($,'23-33 41 17','Terminal Air Units',#7272,$,$); +#7289=IFCCLASSIFICATIONREFERENCE($,'23-33 41 17 11','Constant Volume Air Terminal Units',#7288,$,$); +#7290=IFCCLASSIFICATIONREFERENCE($,'23-33 41 17 11 11','Dual Duct Constant Volume Air Terminal Units',#7289,$,$); +#7291=IFCCLASSIFICATIONREFERENCE($,'23-33 41 17 11 13','Single Duct Constant Volume Air Terminal Units',#7289,$,$); +#7292=IFCCLASSIFICATIONREFERENCE($,'23-33 41 17 13','Variable Air Volume Terminal Units',#7288,$,$); +#7293=IFCCLASSIFICATIONREFERENCE($,'23-33 41 17 13 11','Dual Duct Variable Air Volume Terminal Units',#7292,$,$); +#7294=IFCCLASSIFICATIONREFERENCE($,'23-33 41 17 13 13','Single Duct Variable Air Volume Terminal Units',#7292,$,$); +#7295=IFCCLASSIFICATIONREFERENCE($,'23-33 41 19','Exhaust Terminals',#7272,$,$); +#7296=IFCCLASSIFICATIONREFERENCE($,'23-33 43 00','HVAC Condenser Units',#6987,$,$); +#7297=IFCCLASSIFICATIONREFERENCE($,'23-33 43 11','Air Cooled Condenser Units',#7296,$,$); +#7298=IFCCLASSIFICATIONREFERENCE($,'23-33 43 11 11','Indoor Air Cooled Condenser Units',#7297,$,$); +#7299=IFCCLASSIFICATIONREFERENCE($,'23-33 43 11 13','Outdoor Air Cooled Condenser Units',#7297,$,$); +#7300=IFCCLASSIFICATIONREFERENCE($,'23-33 43 13','Evaporative Condenser Units',#7296,$,$); +#7301=IFCCLASSIFICATIONREFERENCE($,'23-33 43 15','Refrigeration Condenser Units',#7296,$,$); +#7302=IFCCLASSIFICATIONREFERENCE($,'23-33 43 15 11','Air Cooled Refrigeration Condenser Units',#7301,$,$); +#7303=IFCCLASSIFICATIONREFERENCE($,'23-33 43 15 13','Water Cooled Refrigeration Condenser Units',#7301,$,$); +#7304=IFCCLASSIFICATIONREFERENCE($,'23-33 43 17','Water Cooled Condenser Units',#7296,$,$); +#7305=IFCCLASSIFICATIONREFERENCE($,'23-33 43 17 11','Indoor Water Cooled Condenser Units',#7304,$,$); +#7306=IFCCLASSIFICATIONREFERENCE($,'23-33 45 00','HVAC Coolers',#6987,$,$); +#7307=IFCCLASSIFICATIONREFERENCE($,'23-33 45 11','HVAC Dry Coolers',#7306,$,$); +#7308=IFCCLASSIFICATIONREFERENCE($,'23-33 45 13','HVAC Evaporative Coolers',#7306,$,$); +#7309=IFCCLASSIFICATIONREFERENCE($,'23-33 47 00','Air Dryers',#6987,$,$); +#7310=IFCCLASSIFICATIONREFERENCE($,'23-33 47 11','Refrigerated Air Dryers',#7309,$,$); +#7311=IFCCLASSIFICATIONREFERENCE($,'23-33 47 13','Regenerative Desiccant Air Dryers',#7309,$,$); +#7312=IFCCLASSIFICATIONREFERENCE($,'23-33 49 00','HVAC Ductwork',#6987,$,$); +#7313=IFCCLASSIFICATIONREFERENCE($,'23-33 49 11','Ventilation Diffusers',#7312,$,$); +#7314=IFCCLASSIFICATIONREFERENCE($,'23-33 49 11 11','Ceiling Ventilation Diffusers',#7313,$,$); +#7315=IFCCLASSIFICATIONREFERENCE($,'23-33 49 11 11 11','Ceiling Linear Ventilation Diffusers',#7314,$,$); +#7316=IFCCLASSIFICATIONREFERENCE($,'23-33 49 11 13','Wall Ventilation Diffusers',#7313,$,$); +#7317=IFCCLASSIFICATIONREFERENCE($,'23-33 49 11 15','Floor Ventilation Diffusers',#7313,$,$); +#7318=IFCCLASSIFICATIONREFERENCE($,'23-33 49 13','Ventilation Ducts',#7312,$,$); +#7319=IFCCLASSIFICATIONREFERENCE($,'23-33 49 13 11','Round Ventilation Ducts',#7318,$,$); +#7320=IFCCLASSIFICATIONREFERENCE($,'23-33 49 13 11 11','Flexible Ventilation Ducts',#7319,$,$); +#7321=IFCCLASSIFICATIONREFERENCE($,'23-33 49 13 13','Square Ventilation Ducts',#7318,$,$); +#7322=IFCCLASSIFICATIONREFERENCE($,'23-33 49 15','Duct Access Panels',#7312,$,$); +#7323=IFCCLASSIFICATIONREFERENCE($,'23-33 49 17','Duct Insulation',#7312,$,$); +#7324=IFCCLASSIFICATIONREFERENCE($,'23-33 49 17 11','Duct Covering Insulation',#7323,$,$); +#7325=IFCCLASSIFICATIONREFERENCE($,'23-33 49 17 13','Duct Liner Insulation',#7323,$,$); +#7326=IFCCLASSIFICATIONREFERENCE($,'23-33 49 19','Ductwork Distribution Collectors',#7312,$,$); +#7327=IFCCLASSIFICATIONREFERENCE($,'23-33 49 21','Ductwork Expansion Vessels',#7312,$,$); +#7328=IFCCLASSIFICATIONREFERENCE($,'23-33 49 21 11','Air Outlets and Inlets',#7327,$,$); +#7329=IFCCLASSIFICATIONREFERENCE($,'23-33 49 21 13','Ductwork Guide Vanes',#7327,$,$); +#7330=IFCCLASSIFICATIONREFERENCE($,'23-33 49 21 15','Ductwork Air Mixers',#7327,$,$); +#7331=IFCCLASSIFICATIONREFERENCE($,'23-33 49 21 17','Ductwork Sound Attenuators',#7327,$,$); +#7332=IFCCLASSIFICATIONREFERENCE($,'23-33 49 23','Grilles',#7312,$,$); +#7333=IFCCLASSIFICATIONREFERENCE($,'23-33 49 23 11','Exhaust Air Grilles',#7332,$,$); +#7334=IFCCLASSIFICATIONREFERENCE($,'23-33 49 23 13','Return Air Grilles',#7332,$,$); +#7335=IFCCLASSIFICATIONREFERENCE($,'23-33 49 23 15','Supply Air Grilles',#7332,$,$); +#7336=IFCCLASSIFICATIONREFERENCE($,'23-33 49 23 17','Transfer Air Grilles',#7332,$,$); +#7337=IFCCLASSIFICATIONREFERENCE($,'23-33 49 25','Ventilation Registers',#7312,$,$); +#7338=IFCCLASSIFICATIONREFERENCE($,'23-33 49 25 11','Exhaust Air Ventilation Registers',#7337,$,$); +#7339=IFCCLASSIFICATIONREFERENCE($,'23-33 49 25 13','Return Air Ventilation Registers',#7337,$,$); +#7340=IFCCLASSIFICATIONREFERENCE($,'23-33 49 25 15','Supply Air Ventilation Registers',#7337,$,$); +#7341=IFCCLASSIFICATIONREFERENCE($,'23-33 49 27','Ventilators',#7312,$,$); +#7342=IFCCLASSIFICATIONREFERENCE($,'23-33 49 27 11','Gravity Ventilators',#7341,$,$); +#7343=IFCCLASSIFICATIONREFERENCE($,'23-33 49 27 13','Intake and Relief Ventilators',#7341,$,$); +#7344=IFCCLASSIFICATIONREFERENCE($,'23-33 49 27 15','Relief Ventilators',#7341,$,$); +#7345=IFCCLASSIFICATIONREFERENCE($,'23-33 49 27 17','Intake Ventilators',#7341,$,$); +#7346=IFCCLASSIFICATIONREFERENCE($,'23-33 49 29','Air Ductwork Accessories',#7312,$,$); +#7347=IFCCLASSIFICATIONREFERENCE($,'23-33 49 29 11','Access Fittings for Air Ductwork',#7346,$,$); +#7348=IFCCLASSIFICATIONREFERENCE($,'23-33 49 29 13','Couplings for Air Ductwork',#7346,$,$); +#7349=IFCCLASSIFICATIONREFERENCE($,'23-33 49 29 15','Hangers for Air Ductwork',#7346,$,$); +#7350=IFCCLASSIFICATIONREFERENCE($,'23-33 49 29 17','Supports for Air Ductwork',#7346,$,$); +#7351=IFCCLASSIFICATIONREFERENCE($,'23-33 49 29 19','Mechanical Fasteners for Air Ductwork',#7346,$,$); +#7352=IFCCLASSIFICATIONREFERENCE($,'23-33 51 00','HVAC Specialized Equipment',#6987,$,$); +#7353=IFCCLASSIFICATIONREFERENCE($,'23-33 51 11','Refrigerant Monitors',#7352,$,$); +#7354=IFCCLASSIFICATIONREFERENCE($,'23-33 51 13','Refrigerant Purge Units',#7352,$,$); +#7355=IFCCLASSIFICATIONREFERENCE($,'23-33 51 15','Ultraviolet Disinfection Lighting',#7352,$,$); +#7356=IFCCLASSIFICATIONREFERENCE($,'23-33 53 00','Solar Water Heating Equipment',#6987,$,$); +#7357=IFCCLASSIFICATIONREFERENCE($,'23-33 53 11','Solar Water Heating Packaged Units',#7356,$,$); +#7358=IFCCLASSIFICATIONREFERENCE($,'23-33 53 13','Solar Water Heating Collector Components',#7356,$,$); +#7359=IFCCLASSIFICATIONREFERENCE($,'23-33 53 13 11','Solar Water Heating Absorber Plates',#7358,$,$); +#7360=IFCCLASSIFICATIONREFERENCE($,'23-33 53 13 13','Solar Water Heating Absorber Tubing',#7358,$,$); +#7361=IFCCLASSIFICATIONREFERENCE($,'23-33 53 13 15','Solar Water Heating Coatings and Surface Treatment',#7358,$,$); +#7362=IFCCLASSIFICATIONREFERENCE($,'23-33 53 13 17','Solar Water Heating Collector Insulation',#7358,$,$); +#7363=IFCCLASSIFICATIONREFERENCE($,'23-33 53 13 19','Solar Water Heating Glazing',#7358,$,$); +#7364=IFCCLASSIFICATIONREFERENCE($,'23-33 53 13 21','Solar Water Heating Housing and Framing',#7358,$,$); +#7365=IFCCLASSIFICATIONREFERENCE($,'23-33 53 13 23','Solar Water Heating Reflectors',#7358,$,$); +#7366=IFCCLASSIFICATIONREFERENCE($,'23-33 53 15','Solar Water Heating Collector Units',#7356,$,$); +#7367=IFCCLASSIFICATIONREFERENCE($,'23-33 53 15 11','Solar Water Heating Flat Plate Collectors',#7366,$,$); +#7368=IFCCLASSIFICATIONREFERENCE($,'23-33 53 15 13','Solar Water Heating Concentrating Collectors',#7366,$,$); +#7369=IFCCLASSIFICATIONREFERENCE($,'23-33 53 15 15','Solar Water Heating Vacuum Tube Collectors',#7366,$,$); +#7370=IFCCLASSIFICATIONREFERENCE($,'23-33 55 00','Energy HVAC Recovery Equipment',#6987,$,$); +#7371=IFCCLASSIFICATIONREFERENCE($,'23-33 55 11','Heat Pipes',#7370,$,$); +#7372=IFCCLASSIFICATIONREFERENCE($,'23-33 55 13','Heat Wheels',#7370,$,$); +#7373=IFCCLASSIFICATIONREFERENCE($,'23-35 00 00','Electrical and Lighting Specific Products and Equipment',#1606,$,$); +#7374=IFCCLASSIFICATIONREFERENCE($,'23-35 11 00','Electrical Generators',#7373,$,$); +#7375=IFCCLASSIFICATIONREFERENCE($,'23-35 11 11','Single Unit Electrical Generators',#7374,$,$); +#7376=IFCCLASSIFICATIONREFERENCE($,'23-35 11 11 11','Engine Electrical Generators',#7375,$,$); +#7377=IFCCLASSIFICATIONREFERENCE($,'23-35 11 11 13','Motor Electrical Generators',#7375,$,$); +#7378=IFCCLASSIFICATIONREFERENCE($,'23-35 11 12','Single Unit Electrical Generator Engines',#7374,$,$); +#7379=IFCCLASSIFICATIONREFERENCE($,'23-35 11 12 11','Electrical Generation Diesel Engines',#7378,$,$); +#7380=IFCCLASSIFICATIONREFERENCE($,'23-35 11 12 13','Electrical Generation Gas Engines',#7378,$,$); +#7381=IFCCLASSIFICATIONREFERENCE($,'23-35 11 12 15','Electrical Generation Natural Gas Engines',#7378,$,$); +#7382=IFCCLASSIFICATIONREFERENCE($,'23-35 11 12 15 11','Electrical Generation Natural Gas Turbines',#7381,$,$); +#7383=IFCCLASSIFICATIONREFERENCE($,'23-35 11 12 17','Electrical Generation Steam Turbines',#7378,$,$); +#7384=IFCCLASSIFICATIONREFERENCE($,'23-35 11 13','Motor Generator Sets',#7374,$,$); +#7385=IFCCLASSIFICATIONREFERENCE($,'23-35 11 13 11','Alternating Current Frequency Converters',#7384,$,$); +#7386=IFCCLASSIFICATIONREFERENCE($,'23-35 11 13 13','Alternating Current Generator Sets',#7384,$,$); +#7387=IFCCLASSIFICATIONREFERENCE($,'23-35 11 13 15','Direct Current Generator Sets',#7384,$,$); +#7388=IFCCLASSIFICATIONREFERENCE($,'23-35 11 13 17','Multiple Frequency Electrical Generator Sets',#7384,$,$); +#7389=IFCCLASSIFICATIONREFERENCE($,'23-35 11 13 19','Multiple Voltage Electrical Generator Sets',#7384,$,$); +#7390=IFCCLASSIFICATIONREFERENCE($,'23-35 11 15','Engine Generator Sets',#7374,$,$); +#7391=IFCCLASSIFICATIONREFERENCE($,'23-35 11 15 11','Diesel Generator Sets',#7390,$,$); +#7392=IFCCLASSIFICATIONREFERENCE($,'23-35 11 15 13','Gas Generator Sets',#7390,$,$); +#7393=IFCCLASSIFICATIONREFERENCE($,'23-35 11 15 15','Natural Gas Generator Sets',#7390,$,$); +#7394=IFCCLASSIFICATIONREFERENCE($,'23-35 11 15 17','Steam Turbine Generator Sets',#7390,$,$); +#7395=IFCCLASSIFICATIONREFERENCE($,'23-35 11 15 19','Thermal Generator Sets',#7390,$,$); +#7396=IFCCLASSIFICATIONREFERENCE($,'23-35 11 15 21','Hydro Turbine Generator Sets',#7390,$,$); +#7397=IFCCLASSIFICATIONREFERENCE($,'23-35 11 15 23','Wind Generator Sets',#7390,$,$); +#7398=IFCCLASSIFICATIONREFERENCE($,'23-35 11 17','Photovoltaic Generators',#7374,$,$); +#7399=IFCCLASSIFICATIONREFERENCE($,'23-35 11 17 11','Photoelectric Cell',#7398,$,$); +#7400=IFCCLASSIFICATIONREFERENCE($,'23-35 11 17 12','Photoelectric Panel',#7398,$,$); +#7401=IFCCLASSIFICATIONREFERENCE($,'23-35 11 17 13','Photovoltaic Array',#7398,$,$); +#7402=IFCCLASSIFICATIONREFERENCE($,'23-35 11 17 15','Photovoltaic Collectors',#7398,$,$); +#7403=IFCCLASSIFICATIONREFERENCE($,'23-35 13 00','Transformers',#7373,$,$); +#7404=IFCCLASSIFICATIONREFERENCE($,'23-35 13 11','Current Transformers',#7403,$,$); +#7405=IFCCLASSIFICATIONREFERENCE($,'23-35 13 13','Instrument Transformers',#7403,$,$); +#7406=IFCCLASSIFICATIONREFERENCE($,'23-35 13 13 11','Current Instrument Transformers',#7405,$,$); +#7407=IFCCLASSIFICATIONREFERENCE($,'23-35 13 13 13','Pulse Instrument Transformers',#7405,$,$); +#7408=IFCCLASSIFICATIONREFERENCE($,'23-35 13 13 15','Voltage Instrument Transformers',#7405,$,$); +#7409=IFCCLASSIFICATIONREFERENCE($,'23-35 13 15','Electrical Network Transformers',#7403,$,$); +#7410=IFCCLASSIFICATIONREFERENCE($,'23-35 13 15 11','Electrical Network Isolation Transformers',#7409,$,$); +#7411=IFCCLASSIFICATIONREFERENCE($,'23-35 13 15 11 11','Electrical Network Dry Isolation Transformers',#7410,$,$); +#7412=IFCCLASSIFICATIONREFERENCE($,'23-35 13 15 11 13','Electrical Network Oil Filled Isolation Transformers',#7410,$,$); +#7413=IFCCLASSIFICATIONREFERENCE($,'23-35 13 15 13','Electrical Network Step Down Transformers',#7409,$,$); +#7414=IFCCLASSIFICATIONREFERENCE($,'23-35 13 15 13 11','Electrical Network Dry Step Down Transformers',#7413,$,$); +#7415=IFCCLASSIFICATIONREFERENCE($,'23-35 13 15 13 13','Electrical Network Oil Filled Step Down Transformers',#7413,$,$); +#7416=IFCCLASSIFICATIONREFERENCE($,'23-35 13 15 15','Electrical Network Step Up Transformers',#7409,$,$); +#7417=IFCCLASSIFICATIONREFERENCE($,'23-35 13 15 15 11','Electrical Network Dry Step Up Transformers',#7416,$,$); +#7418=IFCCLASSIFICATIONREFERENCE($,'23-35 13 15 15 13','Electrical Network Oil Filled Step Up Transformers',#7416,$,$); +#7419=IFCCLASSIFICATIONREFERENCE($,'23-35 13 17','Power Transformers',#7403,$,$); +#7420=IFCCLASSIFICATIONREFERENCE($,'23-35 13 17 11','Power Harmonic Mitigation Transformers',#7419,$,$); +#7421=IFCCLASSIFICATIONREFERENCE($,'23-35 13 17 11 11','Power Dry Harmonic Mitigation Transformers',#7420,$,$); +#7422=IFCCLASSIFICATIONREFERENCE($,'23-35 13 17 11 13','Power Oil Filled Harmonic Mitigation Transformers',#7420,$,$); +#7423=IFCCLASSIFICATIONREFERENCE($,'23-35 13 17 13','Power Isolation Transformers',#7419,$,$); +#7424=IFCCLASSIFICATIONREFERENCE($,'23-35 13 17 13 11','Power Dry Isolation Transformers',#7423,$,$); +#7425=IFCCLASSIFICATIONREFERENCE($,'23-35 13 17 13 13','Power Oil Filled Isolation Transformers',#7423,$,$); +#7426=IFCCLASSIFICATIONREFERENCE($,'23-35 13 17 15','Power Step Down Transformers',#7419,$,$); +#7427=IFCCLASSIFICATIONREFERENCE($,'23-35 13 17 15 11','Power Dry Step Down Transformers',#7426,$,$); +#7428=IFCCLASSIFICATIONREFERENCE($,'23-35 13 17 15 13','Power Oil Filled Step Down Transformers',#7426,$,$); +#7429=IFCCLASSIFICATIONREFERENCE($,'23-35 13 17 17','Power Step Up Transformers',#7419,$,$); +#7430=IFCCLASSIFICATIONREFERENCE($,'23-35 13 17 17 11','Power Dry Step Up Transformers',#7429,$,$); +#7431=IFCCLASSIFICATIONREFERENCE($,'23-35 13 17 17 13','Power Oil Filled Step Up Transformers',#7429,$,$); +#7432=IFCCLASSIFICATIONREFERENCE($,'23-35 13 19','Transformer Accessories',#7403,$,$); +#7433=IFCCLASSIFICATIONREFERENCE($,'23-35 13 19 11','Transformer Commutators',#7432,$,$); +#7434=IFCCLASSIFICATIONREFERENCE($,'23-35 13 19 13','Transformer Ballasts',#7432,$,$); +#7435=IFCCLASSIFICATIONREFERENCE($,'23-35 15 00','Electric Motors',#7373,$,$); +#7436=IFCCLASSIFICATIONREFERENCE($,'23-35 15 11','Alternating Current (AC) Motors',#7435,$,$); +#7437=IFCCLASSIFICATIONREFERENCE($,'23-35 15 11 11','Single Phase AC Motors',#7436,$,$); +#7438=IFCCLASSIFICATIONREFERENCE($,'23-35 15 11 11 11','Multi Speed Single Phase AC Motors',#7437,$,$); +#7439=IFCCLASSIFICATIONREFERENCE($,'23-35 15 11 11 13','Single Speed Single Phase AC Motors',#7437,$,$); +#7440=IFCCLASSIFICATIONREFERENCE($,'23-35 15 11 11 15','Synchronous Single Phase AC Motors',#7437,$,$); +#7441=IFCCLASSIFICATIONREFERENCE($,'23-35 15 11 13','Three Phase AC Motors',#7436,$,$); +#7442=IFCCLASSIFICATIONREFERENCE($,'23-35 15 11 13 11','Multi Speed Three Phase AC Motors',#7441,$,$); +#7443=IFCCLASSIFICATIONREFERENCE($,'23-35 15 11 13 13','Single Speed Three Phase AC Motors',#7441,$,$); +#7444=IFCCLASSIFICATIONREFERENCE($,'23-35 15 11 13 15','Synchronous Three Phase AC Motors',#7441,$,$); +#7445=IFCCLASSIFICATIONREFERENCE($,'23-35 15 13','Direct Current (DC) Motors',#7435,$,$); +#7446=IFCCLASSIFICATIONREFERENCE($,'23-35 15 13 11','Brushless DC Motors',#7445,$,$); +#7447=IFCCLASSIFICATIONREFERENCE($,'23-35 15 13 13','Compound Wound DC Motors',#7445,$,$); +#7448=IFCCLASSIFICATIONREFERENCE($,'23-35 15 13 15','Coreless DC Motors',#7445,$,$); +#7449=IFCCLASSIFICATIONREFERENCE($,'23-35 15 13 17','Limited Angle Torque DC Motors',#7445,$,$); +#7450=IFCCLASSIFICATIONREFERENCE($,'23-35 15 13 19','Linear DC Motors',#7445,$,$); +#7451=IFCCLASSIFICATIONREFERENCE($,'23-35 15 13 21','Permanent Magnetic DC Motors',#7445,$,$); +#7452=IFCCLASSIFICATIONREFERENCE($,'23-35 15 13 23','Series Wound DC Motors',#7445,$,$); +#7453=IFCCLASSIFICATIONREFERENCE($,'23-35 15 13 25','Shunt Wound DC Motors',#7445,$,$); +#7454=IFCCLASSIFICATIONREFERENCE($,'23-35 15 13 27','Step DC Motors',#7445,$,$); +#7455=IFCCLASSIFICATIONREFERENCE($,'23-35 15 15','DC Servo Motors',#7435,$,$); +#7456=IFCCLASSIFICATIONREFERENCE($,'23-35 15 17','Dynamotors',#7435,$,$); +#7457=IFCCLASSIFICATIONREFERENCE($,'23-35 15 19','Hydraulic Driven Motors',#7435,$,$); +#7458=IFCCLASSIFICATIONREFERENCE($,'23-35 15 21','Pneumatic Driven Motors',#7435,$,$); +#7459=IFCCLASSIFICATIONREFERENCE($,'23-35 15 23','Steam Driven Motors',#7435,$,$); +#7460=IFCCLASSIFICATIONREFERENCE($,'23-35 17 00','Variable Speed Drives',#7373,$,$); +#7461=IFCCLASSIFICATIONREFERENCE($,'23-35 17 11','Direct Current Electronic Speed Controller Drives',#7460,$,$); +#7462=IFCCLASSIFICATIONREFERENCE($,'23-35 17 13','Slip Controlled Drives',#7460,$,$); +#7463=IFCCLASSIFICATIONREFERENCE($,'23-35 17 15','Variable Frequency Drives',#7460,$,$); +#7464=IFCCLASSIFICATIONREFERENCE($,'23-35 17 15 11','Pulse Width Variable Frequency Drives',#7463,$,$); +#7465=IFCCLASSIFICATIONREFERENCE($,'23-35 17 15 13','Current Source Input Variable Frequency Drives',#7463,$,$); +#7466=IFCCLASSIFICATIONREFERENCE($,'23-35 17 15 15','Variable Voltage Input Variable Frequency Drives',#7463,$,$); +#7467=IFCCLASSIFICATIONREFERENCE($,'23-35 19 00','Batteries',#7373,$,$); +#7468=IFCCLASSIFICATIONREFERENCE($,'23-35 19 11','Battery Racks',#7467,$,$); +#7469=IFCCLASSIFICATIONREFERENCE($,'23-35 19 13','Non Rechargeable Batteries',#7467,$,$); +#7470=IFCCLASSIFICATIONREFERENCE($,'23-35 19 13 11','Alkaline Batteries',#7469,$,$); +#7471=IFCCLASSIFICATIONREFERENCE($,'23-35 19 13 13','Dry Cell Batteries',#7469,$,$); +#7472=IFCCLASSIFICATIONREFERENCE($,'23-35 19 13 15','Lithium Batteries',#7469,$,$); +#7473=IFCCLASSIFICATIONREFERENCE($,'23-35 19 13 17','Silver Oxide Batteries',#7469,$,$); +#7474=IFCCLASSIFICATIONREFERENCE($,'23-35 19 13 19','Zinc Air Batteries',#7469,$,$); +#7475=IFCCLASSIFICATIONREFERENCE($,'23-35 19 13 21','Zinc Coal Batteries',#7469,$,$); +#7476=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15','Rechargeable Batteries',#7467,$,$); +#7477=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15 11','Alkaline Batteries',#7476,$,$); +#7478=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15 13','Lead Acid Batteries',#7476,$,$); +#7479=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15 13 11','Sealed Lead Acid Batteries',#7478,$,$); +#7480=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15 13 13','Wet Cell Lead Acid Batteries',#7478,$,$); +#7481=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15 15','Lithium Batteries',#7476,$,$); +#7482=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15 17','Manganese Batteries',#7476,$,$); +#7483=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15 19','Mercuric Oxide Batteries',#7476,$,$); +#7484=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15 21','Nickel Cadmium Batteries',#7476,$,$); +#7485=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15 23','Nickel Hydrogen Batteries',#7476,$,$); +#7486=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15 25','Nickel Iron Batteries',#7476,$,$); +#7487=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15 27','Nickel Metal Hydride Batteries',#7476,$,$); +#7488=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15 29','Nickel Sodium Chloride Batteries',#7476,$,$); +#7489=IFCCLASSIFICATIONREFERENCE($,'23-35 19 15 31','Silver Oxide Batteries',#7476,$,$); +#7490=IFCCLASSIFICATIONREFERENCE($,'23-35 21 00','Battery Chargers',#7373,$,$); +#7491=IFCCLASSIFICATIONREFERENCE($,'23-35 23 00','Power Conditioning Equipment',#7373,$,$); +#7492=IFCCLASSIFICATIONREFERENCE($,'23-35 23 11','Harmonic Control Devices',#7491,$,$); +#7493=IFCCLASSIFICATIONREFERENCE($,'23-35 23 11 11','Electric Interference Suppressor Filters',#7492,$,$); +#7494=IFCCLASSIFICATIONREFERENCE($,'23-35 23 11 13','Harmonic Filters',#7492,$,$); +#7495=IFCCLASSIFICATIONREFERENCE($,'23-35 23 13','Power Converters',#7491,$,$); +#7496=IFCCLASSIFICATIONREFERENCE($,'23-35 23 13 11','Rotary Converters',#7495,$,$); +#7497=IFCCLASSIFICATIONREFERENCE($,'23-35 23 15','Static Power Converters',#7491,$,$); +#7498=IFCCLASSIFICATIONREFERENCE($,'23-35 23 15 11','Static Rectifiers',#7497,$,$); +#7499=IFCCLASSIFICATIONREFERENCE($,'23-35 23 15 13','Ondulators',#7497,$,$); +#7500=IFCCLASSIFICATIONREFERENCE($,'23-35 23 15 15','Combined Converter Sets',#7497,$,$); +#7501=IFCCLASSIFICATIONREFERENCE($,'23-35 23 15 17','Direct Current (DC) Drive Controllers',#7497,$,$); +#7502=IFCCLASSIFICATIONREFERENCE($,'23-35 23 15 19','Slip Controllers',#7497,$,$); +#7503=IFCCLASSIFICATIONREFERENCE($,'23-35 23 15 21','Static Frequency Converters',#7497,$,$); +#7504=IFCCLASSIFICATIONREFERENCE($,'23-35 23 15 23','Static Uninterruptible Power Supplies',#7497,$,$); +#7505=IFCCLASSIFICATIONREFERENCE($,'23-35 23 15 25','Variable Frequency Controllers',#7497,$,$); +#7506=IFCCLASSIFICATIONREFERENCE($,'23-35 23 15 27','Frequency Changers',#7497,$,$); +#7507=IFCCLASSIFICATIONREFERENCE($,'23-35 23 15 29','Rotary Uninterruptible Power Units',#7497,$,$); +#7508=IFCCLASSIFICATIONREFERENCE($,'23-35 23 17','Power Inverters',#7491,$,$); +#7509=IFCCLASSIFICATIONREFERENCE($,'23-35 23 17 11','Commutator Inverters',#7508,$,$); +#7510=IFCCLASSIFICATIONREFERENCE($,'23-35 23 17 13','Solid State Inverters',#7508,$,$); +#7511=IFCCLASSIFICATIONREFERENCE($,'23-35 23 19','Powerfactor Correction Devices',#7491,$,$); +#7512=IFCCLASSIFICATIONREFERENCE($,'23-35 23 19 11','Capacitive and Inductive Power Correction Devices',#7511,$,$); +#7513=IFCCLASSIFICATIONREFERENCE($,'23-35 23 19 13','Capacitive Power Correction Devices',#7511,$,$); +#7514=IFCCLASSIFICATIONREFERENCE($,'23-35 23 19 15','Inductive Power Correction Devices',#7511,$,$); +#7515=IFCCLASSIFICATIONREFERENCE($,'23-35 23 19 17','Capacitors',#7511,$,$); +#7516=IFCCLASSIFICATIONREFERENCE($,'23-35 23 19 19','Power Factor Controls (Cosines Phi)',#7511,$,$); +#7517=IFCCLASSIFICATIONREFERENCE($,'23-35 23 21','Uninterrupted Power Supply (UPS) Units',#7491,$,$); +#7518=IFCCLASSIFICATIONREFERENCE($,'23-35 23 21 11','Uninterruptible Power Supply Component Systems',#7517,$,$); +#7519=IFCCLASSIFICATIONREFERENCE($,'23-35 23 21 13','Uninterruptible Power Supply Packaged Units',#7517,$,$); +#7520=IFCCLASSIFICATIONREFERENCE($,'23-35 25 00','Electrical Instrumentation and Controls',#7373,$,$); +#7521=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11','Electrical Meters',#7520,$,$); +#7522=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 11','Power Meters',#7521,$,$); +#7523=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 13','Voltage Meters',#7521,$,$); +#7524=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 15','Resistance Meters',#7521,$,$); +#7525=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 17','Frequency Meters',#7521,$,$); +#7526=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 19','Multi Meters',#7521,$,$); +#7527=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 21','Current Meters',#7521,$,$); +#7528=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 23','Amp Hour Meters',#7521,$,$); +#7529=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 25','Power Factor Meters',#7521,$,$); +#7530=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 27','Kilowatt Hour Meters',#7521,$,$); +#7531=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 27 11','Electromechanical Remote Kilowatt Hour Meters',#7530,$,$); +#7532=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 27 13','Electromechancial Kilowatt Hour Meters',#7530,$,$); +#7533=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 27 15','Solid State Remote Kilowatt Hour Meters',#7530,$,$); +#7534=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 27 17','Solid State Kilowatt Hour Meters',#7530,$,$); +#7535=IFCCLASSIFICATIONREFERENCE($,'23-35 25 11 29','Multiple Tariff Meters',#7521,$,$); +#7536=IFCCLASSIFICATIONREFERENCE($,'23-35 25 13','Electrical Energy Recording Devices',#7520,$,$); +#7537=IFCCLASSIFICATIONREFERENCE($,'23-35 25 13 11','Watt Hour Recorders',#7536,$,$); +#7538=IFCCLASSIFICATIONREFERENCE($,'23-35 25 15','Electrical Network Protection Modules',#7520,$,$); +#7539=IFCCLASSIFICATIONREFERENCE($,'23-35 25 17','Electrical Power Protection Modules',#7520,$,$); +#7540=IFCCLASSIFICATIONREFERENCE($,'23-35 25 19','Motor Starters',#7520,$,$); +#7541=IFCCLASSIFICATIONREFERENCE($,'23-35 25 21','Programmable Logic Controllers',#7520,$,$); +#7542=IFCCLASSIFICATIONREFERENCE($,'23-35 25 23','Electrical Control Panels',#7520,$,$); +#7543=IFCCLASSIFICATIONREFERENCE($,'23-35 25 25','Electrical Line Supervisor Sets',#7520,$,$); +#7544=IFCCLASSIFICATIONREFERENCE($,'23-35 27 00','Electrical Terminals',#7373,$,$); +#7545=IFCCLASSIFICATIONREFERENCE($,'23-35 27 11','Electrical Receptacles',#7544,$,$); +#7546=IFCCLASSIFICATIONREFERENCE($,'23-35 27 11 11','Electrical Receptacle Terminal Units',#7545,$,$); +#7547=IFCCLASSIFICATIONREFERENCE($,'23-35 27 11 13','Ground Fault Receptacles',#7545,$,$); +#7548=IFCCLASSIFICATIONREFERENCE($,'23-35 27 11 15','Electrical Extension Cords',#7545,$,$); +#7549=IFCCLASSIFICATIONREFERENCE($,'23-35 27 11 17','Electrical Receptacle Accessories',#7545,$,$); +#7550=IFCCLASSIFICATIONREFERENCE($,'23-35 27 11 17 11','Electrical Telltale Lamps',#7549,$,$); +#7551=IFCCLASSIFICATIONREFERENCE($,'23-35 27 11 17 13','Electrical Receptacle Protectors',#7549,$,$); +#7552=IFCCLASSIFICATIONREFERENCE($,'23-35 27 11 17 15','Electrical Receptacle Adapters',#7549,$,$); +#7553=IFCCLASSIFICATIONREFERENCE($,'23-35 27 13','Electrical Plug Connectors',#7544,$,$); +#7554=IFCCLASSIFICATIONREFERENCE($,'23-35 29 00','Circuit Breakers',#7373,$,$); +#7555=IFCCLASSIFICATIONREFERENCE($,'23-35 29 11','Air Circuit Breakers',#7554,$,$); +#7556=IFCCLASSIFICATIONREFERENCE($,'23-35 29 11 11','Network Distribution Air Circuit Breakers',#7555,$,$); +#7557=IFCCLASSIFICATIONREFERENCE($,'23-35 29 11 13','Power Distribution Air Circuit Breakers',#7555,$,$); +#7558=IFCCLASSIFICATIONREFERENCE($,'23-35 29 13','Gas Circuit Breakers',#7554,$,$); +#7559=IFCCLASSIFICATIONREFERENCE($,'23-35 29 13 11','Network Distribution Gas Circuit Breakers',#7558,$,$); +#7560=IFCCLASSIFICATIONREFERENCE($,'23-35 29 13 13','Power Distribution Gas Circuit Breakers',#7558,$,$); +#7561=IFCCLASSIFICATIONREFERENCE($,'23-35 29 15','Ground Fault Circuit Breakers',#7554,$,$); +#7562=IFCCLASSIFICATIONREFERENCE($,'23-35 29 17','Molded Case Circuit Breakers',#7554,$,$); +#7563=IFCCLASSIFICATIONREFERENCE($,'23-35 29 17 11','Shunt Molded Case Circuit Breakers',#7562,$,$); +#7564=IFCCLASSIFICATIONREFERENCE($,'23-35 29 19','Oil Circuit Breakers',#7554,$,$); +#7565=IFCCLASSIFICATIONREFERENCE($,'23-35 29 19 11','Network Distribution Oil Circuit Breakers',#7564,$,$); +#7566=IFCCLASSIFICATIONREFERENCE($,'23-35 29 19 13','Power Distribution Oil Circuit Breakers',#7564,$,$); +#7567=IFCCLASSIFICATIONREFERENCE($,'23-35 29 21','Vacuum Circuit Breakers',#7554,$,$); +#7568=IFCCLASSIFICATIONREFERENCE($,'23-35 29 21 11','Network Distribution Vacuum Circuit Breakers',#7567,$,$); +#7569=IFCCLASSIFICATIONREFERENCE($,'23-35 29 21 13','Power Distribution Vacuum Circuit Breakers',#7567,$,$); +#7570=IFCCLASSIFICATIONREFERENCE($,'23-35 29 23','Ground Fault Circuit Interrupters',#7554,$,$); +#7571=IFCCLASSIFICATIONREFERENCE($,'23-35 29 25','Network Protectors',#7554,$,$); +#7572=IFCCLASSIFICATIONREFERENCE($,'23-35 29 27','Electrical Disconnects',#7554,$,$); +#7573=IFCCLASSIFICATIONREFERENCE($,'23-35 29 27 11','Air Disconnects',#7572,$,$); +#7574=IFCCLASSIFICATIONREFERENCE($,'23-35 29 27 13','Vacuum Disconnects',#7572,$,$); +#7575=IFCCLASSIFICATIONREFERENCE($,'23-35 29 27 15','Gas Disconnects',#7572,$,$); +#7576=IFCCLASSIFICATIONREFERENCE($,'23-35 29 29','Fuses',#7554,$,$); +#7577=IFCCLASSIFICATIONREFERENCE($,'23-35 29 29 11','Fuse Panels',#7576,$,$); +#7578=IFCCLASSIFICATIONREFERENCE($,'23-35 29 29 13','Fuse Holders',#7576,$,$); +#7579=IFCCLASSIFICATIONREFERENCE($,'23-35 31 00','Electrical Power Distribution Devices',#7373,$,$); +#7580=IFCCLASSIFICATIONREFERENCE($,'23-35 31 11','Power Supply Devices',#7579,$,$); +#7581=IFCCLASSIFICATIONREFERENCE($,'23-35 31 13','Distribution Panel Boards',#7579,$,$); +#7582=IFCCLASSIFICATIONREFERENCE($,'23-35 31 15','Electrical Distribution Control Panels',#7579,$,$); +#7583=IFCCLASSIFICATIONREFERENCE($,'23-35 31 17','Electrical Panel Boards',#7579,$,$); +#7584=IFCCLASSIFICATIONREFERENCE($,'23-35 31 19','Electrical Panel Meter Sockets',#7579,$,$); +#7585=IFCCLASSIFICATIONREFERENCE($,'23-35 31 21','Load Centers',#7579,$,$); +#7586=IFCCLASSIFICATIONREFERENCE($,'23-35 31 23','Motor Control Centers',#7579,$,$); +#7587=IFCCLASSIFICATIONREFERENCE($,'23-35 31 25','Power Control and Monitoring Assemblies',#7579,$,$); +#7588=IFCCLASSIFICATIONREFERENCE($,'23-35 31 27','Power Distribution Units',#7579,$,$); +#7589=IFCCLASSIFICATIONREFERENCE($,'23-35 31 27 11','Multiple Section Power Distribution Units',#7588,$,$); +#7590=IFCCLASSIFICATIONREFERENCE($,'23-35 31 27 13','Stand Alone Power Distribution Units',#7588,$,$); +#7591=IFCCLASSIFICATIONREFERENCE($,'23-35 31 29','Switchboards',#7579,$,$); +#7592=IFCCLASSIFICATIONREFERENCE($,'23-35 31 29 11','Distribution Switchboards',#7591,$,$); +#7593=IFCCLASSIFICATIONREFERENCE($,'23-35 31 29 13','Paralleling Switchboards',#7591,$,$); +#7594=IFCCLASSIFICATIONREFERENCE($,'23-35 31 31','Switchgear',#7579,$,$); +#7595=IFCCLASSIFICATIONREFERENCE($,'23-35 31 31 11','Distribution Switchgear',#7594,$,$); +#7596=IFCCLASSIFICATIONREFERENCE($,'23-35 31 31 11 11','Electronic Controlled Distribution Switchgear',#7595,$,$); +#7597=IFCCLASSIFICATIONREFERENCE($,'23-35 31 31 11 13','Mechanically Controlled Distribution Switchgear',#7595,$,$); +#7598=IFCCLASSIFICATIONREFERENCE($,'23-35 31 31 11 15','Remote Controlled Distribution Switchgear',#7595,$,$); +#7599=IFCCLASSIFICATIONREFERENCE($,'23-35 31 31 11 17','Time Controlled Distribution Switchgear',#7595,$,$); +#7600=IFCCLASSIFICATIONREFERENCE($,'23-35 31 31 13','Paralleling Switchgear',#7594,$,$); +#7601=IFCCLASSIFICATIONREFERENCE($,'23-35 31 31 13 11','Electronic Controlled Paralleling Switchgear',#7600,$,$); +#7602=IFCCLASSIFICATIONREFERENCE($,'23-35 31 31 13 13','Mechanically Controlled Paralleling Switchgear',#7600,$,$); +#7603=IFCCLASSIFICATIONREFERENCE($,'23-35 31 31 13 15','Remote Controlled Paralleling Switchgear',#7600,$,$); +#7604=IFCCLASSIFICATIONREFERENCE($,'23-35 31 31 13 17','Time Controlled Paralleling Switchgear',#7600,$,$); +#7605=IFCCLASSIFICATIONREFERENCE($,'23-35 31 33','Electrical Busbars',#7579,$,$); +#7606=IFCCLASSIFICATIONREFERENCE($,'23-35 31 33 11','Aluminum Electrical Busbars',#7605,$,$); +#7607=IFCCLASSIFICATIONREFERENCE($,'23-35 31 33 13','Copper Electrical Busbars',#7605,$,$); +#7608=IFCCLASSIFICATIONREFERENCE($,'23-35 31 35','Electrical Feeders',#7579,$,$); +#7609=IFCCLASSIFICATIONREFERENCE($,'23-35 33 00','Electrical Ducting Wireways Components',#7373,$,$); +#7610=IFCCLASSIFICATIONREFERENCE($,'23-35 33 11','Electrical Service Penetrations',#7609,$,$); +#7611=IFCCLASSIFICATIONREFERENCE($,'23-35 33 13','Electrical Conductor Components',#7609,$,$); +#7612=IFCCLASSIFICATIONREFERENCE($,'23-35 33 13 11','Electrical Conductor Rails',#7611,$,$); +#7613=IFCCLASSIFICATIONREFERENCE($,'23-35 33 13 13','Electrical Conductor Couplings',#7611,$,$); +#7614=IFCCLASSIFICATIONREFERENCE($,'23-35 33 13 15','Electrical Conductor Insulation',#7611,$,$); +#7615=IFCCLASSIFICATIONREFERENCE($,'23-35 33 13 17','Electrical Support Wires',#7611,$,$); +#7616=IFCCLASSIFICATIONREFERENCE($,'23-35 33 13 19','Conductor Mechanical Fasteners',#7611,$,$); +#7617=IFCCLASSIFICATIONREFERENCE($,'23-35 33 15','Electrical Junction Boxes',#7609,$,$); +#7618=IFCCLASSIFICATIONREFERENCE($,'23-35 33 15 11','Electrical Ceiling Junction Boxes',#7617,$,$); +#7619=IFCCLASSIFICATIONREFERENCE($,'23-35 33 15 13','Electrical Wall Junction Boxes',#7617,$,$); +#7620=IFCCLASSIFICATIONREFERENCE($,'23-35 33 17','Electrical Conduits',#7609,$,$); +#7621=IFCCLASSIFICATIONREFERENCE($,'23-35 33 17 11','Electrical Cable Reels',#7620,$,$); +#7622=IFCCLASSIFICATIONREFERENCE($,'23-35 33 17 13','Mechanical Fasteners for Conduits',#7620,$,$); +#7623=IFCCLASSIFICATIONREFERENCE($,'23-35 33 17 15','Mechanical Fasteners for Trunking',#7620,$,$); +#7624=IFCCLASSIFICATIONREFERENCE($,'23-35 33 19','Electrical Cable Trays',#7609,$,$); +#7625=IFCCLASSIFICATIONREFERENCE($,'23-35 33 21','Electrical Bus Ducts',#7609,$,$); +#7626=IFCCLASSIFICATIONREFERENCE($,'23-35 33 21 11','Aluminum Electrical Bus Ducts',#7625,$,$); +#7627=IFCCLASSIFICATIONREFERENCE($,'23-35 33 21 13','Copper Electrical Bus Ducts',#7625,$,$); +#7628=IFCCLASSIFICATIONREFERENCE($,'23-35 33 23','Electrical Racks',#7609,$,$); +#7629=IFCCLASSIFICATIONREFERENCE($,'23-35 33 23 11','Horizontal Electrical Racks',#7628,$,$); +#7630=IFCCLASSIFICATIONREFERENCE($,'23-35 33 23 13','Vertical Electrical Racks',#7628,$,$); +#7631=IFCCLASSIFICATIONREFERENCE($,'23-35 33 25','Electrical Wireways',#7609,$,$); +#7632=IFCCLASSIFICATIONREFERENCE($,'23-35 33 25 11','Underfloor Electrical Wireways',#7631,$,$); +#7633=IFCCLASSIFICATIONREFERENCE($,'23-35 33 25 13','Vertical Electrical Wire Raceways',#7631,$,$); +#7634=IFCCLASSIFICATIONREFERENCE($,'23-35 33 25 15','Horizontal Electrical Wire Raceways',#7631,$,$); +#7635=IFCCLASSIFICATIONREFERENCE($,'23-35 33 25 17','Ceiling Grid Electrical Systems',#7631,$,$); +#7636=IFCCLASSIFICATIONREFERENCE($,'23-35 33 25 17 11','Ceiling Grid Electrical Wire Tracks',#7635,$,$); +#7637=IFCCLASSIFICATIONREFERENCE($,'23-35 33 25 17 13','Ceiling Grid Electrical Wire Track Connectors',#7635,$,$); +#7638=IFCCLASSIFICATIONREFERENCE($,'23-35 35 00','Electrical Contactors',#7373,$,$); +#7639=IFCCLASSIFICATIONREFERENCE($,'23-35 37 00','Electrical Switches',#7373,$,$); +#7640=IFCCLASSIFICATIONREFERENCE($,'23-35 37 11','Automatic Transfer Switches',#7639,$,$); +#7641=IFCCLASSIFICATIONREFERENCE($,'23-35 37 11 11','Normal Power Seeking Automatic Transfer Switches',#7640,$,$); +#7642=IFCCLASSIFICATIONREFERENCE($,'23-35 37 11 13','Power Seeking Automatic Transfer Switches',#7640,$,$); +#7643=IFCCLASSIFICATIONREFERENCE($,'23-35 37 13','Manual Transfer Switches',#7639,$,$); +#7644=IFCCLASSIFICATIONREFERENCE($,'23-35 37 15','Barrel Switches',#7639,$,$); +#7645=IFCCLASSIFICATIONREFERENCE($,'23-35 37 15 11','Barrel Key Switches',#7644,$,$); +#7646=IFCCLASSIFICATIONREFERENCE($,'23-35 37 17','Dimmer Control Switches',#7639,$,$); +#7647=IFCCLASSIFICATIONREFERENCE($,'23-35 37 17 11','Lighting Dimmer Rheostats',#7646,$,$); +#7648=IFCCLASSIFICATIONREFERENCE($,'23-35 37 17 12','Ganged Lighting Dimmers',#7646,$,$); +#7649=IFCCLASSIFICATIONREFERENCE($,'23-35 37 17 13','Dimmers',#7646,$,$); +#7650=IFCCLASSIFICATIONREFERENCE($,'23-35 37 19','Disconnect Switches',#7639,$,$); +#7651=IFCCLASSIFICATIONREFERENCE($,'23-35 37 19 11','Fused Disconnect Switches',#7650,$,$); +#7652=IFCCLASSIFICATIONREFERENCE($,'23-35 37 19 13','Non Fused Disconnect Switches',#7650,$,$); +#7653=IFCCLASSIFICATIONREFERENCE($,'23-35 37 21','Drum Switches',#7639,$,$); +#7654=IFCCLASSIFICATIONREFERENCE($,'23-35 37 23','Flow Switches',#7639,$,$); +#7655=IFCCLASSIFICATIONREFERENCE($,'23-35 37 25','Key Lock Switches',#7639,$,$); +#7656=IFCCLASSIFICATIONREFERENCE($,'23-35 37 27','Limit Switches',#7639,$,$); +#7657=IFCCLASSIFICATIONREFERENCE($,'23-35 37 27 11','Level Switches',#7656,$,$); +#7658=IFCCLASSIFICATIONREFERENCE($,'23-35 37 27 13','Reed Switches',#7656,$,$); +#7659=IFCCLASSIFICATIONREFERENCE($,'23-35 37 29','Modular Wiring System Switches',#7639,$,$); +#7660=IFCCLASSIFICATIONREFERENCE($,'23-35 37 31','Photocell Switches',#7639,$,$); +#7661=IFCCLASSIFICATIONREFERENCE($,'23-35 37 33','Pressure Switches',#7639,$,$); +#7662=IFCCLASSIFICATIONREFERENCE($,'23-35 37 33 11','Differential Pressure Switches',#7661,$,$); +#7663=IFCCLASSIFICATIONREFERENCE($,'23-35 37 35','Rocker Switches',#7639,$,$); +#7664=IFCCLASSIFICATIONREFERENCE($,'23-35 37 35 11','Mercury Switches',#7663,$,$); +#7665=IFCCLASSIFICATIONREFERENCE($,'23-35 37 37','Time Switches',#7639,$,$); +#7666=IFCCLASSIFICATIONREFERENCE($,'23-35 37 39','Foot Switches',#7639,$,$); +#7667=IFCCLASSIFICATIONREFERENCE($,'23-35 37 41','Joysticks',#7639,$,$); +#7668=IFCCLASSIFICATIONREFERENCE($,'23-35 37 43','Programmable Logic Control Switches',#7639,$,$); +#7669=IFCCLASSIFICATIONREFERENCE($,'23-35 37 45','Proximity Switches',#7639,$,$); +#7670=IFCCLASSIFICATIONREFERENCE($,'23-35 37 47','Pull Chain Switches',#7639,$,$); +#7671=IFCCLASSIFICATIONREFERENCE($,'23-35 37 49','Push Button Switches',#7639,$,$); +#7672=IFCCLASSIFICATIONREFERENCE($,'23-35 37 51','Radio Frequency Switches',#7639,$,$); +#7673=IFCCLASSIFICATIONREFERENCE($,'23-35 37 53','Rotary Switches',#7639,$,$); +#7674=IFCCLASSIFICATIONREFERENCE($,'23-35 37 55','Slide Switches',#7639,$,$); +#7675=IFCCLASSIFICATIONREFERENCE($,'23-35 37 57','Snap Switches',#7639,$,$); +#7676=IFCCLASSIFICATIONREFERENCE($,'23-35 37 59','Speed Switches',#7639,$,$); +#7677=IFCCLASSIFICATIONREFERENCE($,'23-35 37 61','Tamper Switches',#7639,$,$); +#7678=IFCCLASSIFICATIONREFERENCE($,'23-35 37 63','Temperature Switches',#7639,$,$); +#7679=IFCCLASSIFICATIONREFERENCE($,'23-35 37 65','Vacuum Switches',#7639,$,$); +#7680=IFCCLASSIFICATIONREFERENCE($,'23-35 39 00','Electric Power Protection Devices',#7373,$,$); +#7681=IFCCLASSIFICATIONREFERENCE($,'23-35 39 11','Electrical Grounding Device',#7680,$,$); +#7682=IFCCLASSIFICATIONREFERENCE($,'23-35 39 13','Earth Connection Electrodes',#7680,$,$); +#7683=IFCCLASSIFICATIONREFERENCE($,'23-35 39 13 11','Electrical Ground Plates',#7682,$,$); +#7684=IFCCLASSIFICATIONREFERENCE($,'23-35 39 13 13','Electrical Ground Rods',#7682,$,$); +#7685=IFCCLASSIFICATIONREFERENCE($,'23-35 39 15','Lightning Protection',#7680,$,$); +#7686=IFCCLASSIFICATIONREFERENCE($,'23-35 39 15 11','Lightning Arresters',#7685,$,$); +#7687=IFCCLASSIFICATIONREFERENCE($,'23-35 39 15 13','Lightning Rods',#7685,$,$); +#7688=IFCCLASSIFICATIONREFERENCE($,'23-35 39 17','Surge Protection Devices',#7680,$,$); +#7689=IFCCLASSIFICATIONREFERENCE($,'23-35 41 00','Electrical Isolation Equipment',#7373,$,$); +#7690=IFCCLASSIFICATIONREFERENCE($,'23-35 41 11','Electronic Chokes',#7689,$,$); +#7691=IFCCLASSIFICATIONREFERENCE($,'23-35 41 13','Signal Converters',#7689,$,$); +#7692=IFCCLASSIFICATIONREFERENCE($,'23-35 43 00','Electrical Relays',#7373,$,$); +#7693=IFCCLASSIFICATIONREFERENCE($,'23-35 43 11','Auxiliary Protective Relays',#7692,$,$); +#7694=IFCCLASSIFICATIONREFERENCE($,'23-35 43 13','Control Relays',#7692,$,$); +#7695=IFCCLASSIFICATIONREFERENCE($,'23-35 43 15','Current Differential Relays',#7692,$,$); +#7696=IFCCLASSIFICATIONREFERENCE($,'23-35 43 15 11','Current Differential Solid State Relays',#7695,$,$); +#7697=IFCCLASSIFICATIONREFERENCE($,'23-35 43 17','General Purpose Relays',#7692,$,$); +#7698=IFCCLASSIFICATIONREFERENCE($,'23-35 43 19','Ground Fault Relays',#7692,$,$); +#7699=IFCCLASSIFICATIONREFERENCE($,'23-35 43 19 11','Ground Fault Solid State Relays',#7698,$,$); +#7700=IFCCLASSIFICATIONREFERENCE($,'23-35 43 21','Load Shedding Relays',#7692,$,$); +#7701=IFCCLASSIFICATIONREFERENCE($,'23-35 43 23','Lockout Relays',#7692,$,$); +#7702=IFCCLASSIFICATIONREFERENCE($,'23-35 43 23 11','Automatic Reset Lockout Relays',#7701,$,$); +#7703=IFCCLASSIFICATIONREFERENCE($,'23-35 43 23 13','Manual Reset Lockout Relays',#7701,$,$); +#7704=IFCCLASSIFICATIONREFERENCE($,'23-35 43 25','Mercury Relays',#7692,$,$); +#7705=IFCCLASSIFICATIONREFERENCE($,'23-35 43 27','Over Current Relays',#7692,$,$); +#7706=IFCCLASSIFICATIONREFERENCE($,'23-35 43 27 11','Overcurrent Directional, Induction Disc Relays',#7705,$,$); +#7707=IFCCLASSIFICATIONREFERENCE($,'23-35 43 27 13','Over Current Induction Disc Relays',#7705,$,$); +#7708=IFCCLASSIFICATIONREFERENCE($,'23-35 43 27 15','Over Current Thermal Relays',#7705,$,$); +#7709=IFCCLASSIFICATIONREFERENCE($,'23-35 43 27 17','Over Current Solid State Relays',#7705,$,$); +#7710=IFCCLASSIFICATIONREFERENCE($,'23-35 43 29','Overload Relays',#7692,$,$); +#7711=IFCCLASSIFICATIONREFERENCE($,'23-35 43 29 11','Overload Solid State Relays',#7710,$,$); +#7712=IFCCLASSIFICATIONREFERENCE($,'23-35 43 31','Phase Failure Relays',#7692,$,$); +#7713=IFCCLASSIFICATIONREFERENCE($,'23-35 43 31 11','Phase Failure Solid State Relays',#7712,$,$); +#7714=IFCCLASSIFICATIONREFERENCE($,'23-35 43 33','Power Relays',#7692,$,$); +#7715=IFCCLASSIFICATIONREFERENCE($,'23-35 43 35','Time Relays',#7692,$,$); +#7716=IFCCLASSIFICATIONREFERENCE($,'23-35 43 35 11','Reverse Current Time Relays',#7715,$,$); +#7717=IFCCLASSIFICATIONREFERENCE($,'23-35 43 35 11 11','Reverse Current Solid State Time Relays',#7716,$,$); +#7718=IFCCLASSIFICATIONREFERENCE($,'23-35 43 35 13','Reverse Power Time Relays',#7715,$,$); +#7719=IFCCLASSIFICATIONREFERENCE($,'23-35 43 35 13 11','Reverse Power Solid State Time Relays',#7718,$,$); +#7720=IFCCLASSIFICATIONREFERENCE($,'23-35 43 35 15','Power Factor Time Relays',#7715,$,$); +#7721=IFCCLASSIFICATIONREFERENCE($,'23-35 43 35 15 11','Power Factor Solid State Time Relays',#7720,$,$); +#7722=IFCCLASSIFICATIONREFERENCE($,'23-35 43 37','Voltage Relays',#7692,$,$); +#7723=IFCCLASSIFICATIONREFERENCE($,'23-35 43 37 11','Under Voltage Relays',#7722,$,$); +#7724=IFCCLASSIFICATIONREFERENCE($,'23-35 43 37 11 11','Under Voltage Solid State Relays',#7723,$,$); +#7725=IFCCLASSIFICATIONREFERENCE($,'23-35 43 37 13','Over Voltage Relays',#7722,$,$); +#7726=IFCCLASSIFICATIONREFERENCE($,'23-35 43 37 13 11','Over Voltage Solid State Relays',#7725,$,$); +#7727=IFCCLASSIFICATIONREFERENCE($,'23-35 43 37 15','Over Under Voltage Relays',#7722,$,$); +#7728=IFCCLASSIFICATIONREFERENCE($,'23-35 43 37 15 11','Over Under Voltage Solid State Relays',#7727,$,$); +#7729=IFCCLASSIFICATIONREFERENCE($,'23-35 45 00','Non Electrical Lighting',#7373,$,$); +#7730=IFCCLASSIFICATIONREFERENCE($,'23-35 45 11','Lanterns',#7729,$,$); +#7731=IFCCLASSIFICATIONREFERENCE($,'23-35 45 11 11','Alcohol Lanterns',#7730,$,$); +#7732=IFCCLASSIFICATIONREFERENCE($,'23-35 45 11 13','Butane Lanterns',#7730,$,$); +#7733=IFCCLASSIFICATIONREFERENCE($,'23-35 45 11 15','Kerosene Lanterns',#7730,$,$); +#7734=IFCCLASSIFICATIONREFERENCE($,'23-35 45 11 17','Natural Gas Lanterns',#7730,$,$); +#7735=IFCCLASSIFICATIONREFERENCE($,'23-35 45 11 19','Propane Lanterns',#7730,$,$); +#7736=IFCCLASSIFICATIONREFERENCE($,'23-35 45 13','Torches',#7729,$,$); +#7737=IFCCLASSIFICATIONREFERENCE($,'23-35 45 13 11','Alcohol Torches',#7736,$,$); +#7738=IFCCLASSIFICATIONREFERENCE($,'23-35 45 13 13','Butane Torches',#7736,$,$); +#7739=IFCCLASSIFICATIONREFERENCE($,'23-35 45 13 15','Kerosene Torches',#7736,$,$); +#7740=IFCCLASSIFICATIONREFERENCE($,'23-35 45 13 17','Natural Gas Torches',#7736,$,$); +#7741=IFCCLASSIFICATIONREFERENCE($,'23-35 45 13 19','Propane Torches',#7736,$,$); +#7742=IFCCLASSIFICATIONREFERENCE($,'23-35 45 15','Lamps',#7729,$,$); +#7743=IFCCLASSIFICATIONREFERENCE($,'23-35 45 15 11','Alcohol Lamps',#7742,$,$); +#7744=IFCCLASSIFICATIONREFERENCE($,'23-35 45 15 13','Butane Lamps',#7742,$,$); +#7745=IFCCLASSIFICATIONREFERENCE($,'23-35 45 15 15','Kerosene Lamps',#7742,$,$); +#7746=IFCCLASSIFICATIONREFERENCE($,'23-35 45 15 17','Natural Gas Lamps',#7742,$,$); +#7747=IFCCLASSIFICATIONREFERENCE($,'23-35 45 15 19','Propane Lamps',#7742,$,$); +#7748=IFCCLASSIFICATIONREFERENCE($,'23-35 45 17','Solar Tubes',#7729,$,$); +#7749=IFCCLASSIFICATIONREFERENCE($,'23-35 45 19','Strobe Light Fixtures',#7729,$,$); +#7750=IFCCLASSIFICATIONREFERENCE($,'23-35 47 00','Electrical Lighting',#7373,$,$); +#7751=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11','Lighting Fixtures',#7750,$,$); +#7752=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 11','Non Weather Rated Lighting Fixtures',#7751,$,$); +#7753=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 11 11','Non Weather Rated Fluorescent Lighting Fixtures',#7752,$,$); +#7754=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 11 13','Non Weather Rated Halogen Lighting Fixtures',#7752,$,$); +#7755=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 11 15','Non Weather Rated High Intensity Discharge Lighting Fixtures',#7752,$,$); +#7756=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 11 17','Non Weather Rated Incandescent Lighting Fixtures',#7752,$,$); +#7757=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 11 19','Non Weather Rated Light Emitting Diode Lighting Fixtures',#7752,$,$); +#7758=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 13','Submersible Lighting Fixtures',#7751,$,$); +#7759=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 13 11','Submersible Fluorescent Lighting Fixtures',#7758,$,$); +#7760=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 13 13','Submersible Halogen Lighting Fixtures',#7758,$,$); +#7761=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 13 15','Submersible High Intensity Discharge Lighting Fixtures',#7758,$,$); +#7762=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 13 17','Submersible Incandescent Lighting Fixtures',#7758,$,$); +#7763=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 13 19','Submersible Light Emitting Diode Lighting Fixtures',#7758,$,$); +#7764=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 15','Weather Rated Lighting Fixtures',#7751,$,$); +#7765=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 15 11','Weather Rated Fluorescent Lighting Fixtures',#7764,$,$); +#7766=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 15 13','Weather Rated Halogen Lighting Fixtures',#7764,$,$); +#7767=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 15 15','Weather Rated High Intensity Discharge Lighting Fixtures',#7764,$,$); +#7768=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 15 17','Weather Rated Incandescent Lighting Fixtures',#7764,$,$); +#7769=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 15 19','Weather Rated Light Emitting Diode Lighting Fixtures',#7764,$,$); +#7770=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 17','Chandelier',#7751,$,$); +#7771=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 18','Explosion Proof Lighting Fixtures',#7751,$,$); +#7772=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 18 11','Explosion Proof Fluorescent Lighting Fixtures',#7771,$,$); +#7773=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 18 13','Explosion Proof Halogen Lighting Fixtures',#7771,$,$); +#7774=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 18 15','Explosion Proof High Intensity Discharge Lighting Fixtures',#7771,$,$); +#7775=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 18 17','Explosion Proof Incandescent Lighting Fixtures',#7771,$,$); +#7776=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 18 19','Explosion Proof Light Emitting Diode Lighting Fixtures',#7771,$,$); +#7777=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 19','Hazardous Lighting Fixtures',#7751,$,$); +#7778=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 19 11','Hazardous Fluorescent Lighting Fixtures',#7777,$,$); +#7779=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 19 13','Hazardous Halogen Lighting Fixtures',#7777,$,$); +#7780=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 19 15','Hazardous High Intensity Discharge Lighting Fixtures',#7777,$,$); +#7781=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 19 17','Hazardous Incandescent Lighting Fixtures',#7777,$,$); +#7782=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 19 19','Hazardous Light Emitting Diode Lighting Fixtures',#7777,$,$); +#7783=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 20','Security Lighting Fixtures',#7751,$,$); +#7784=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 21','Specialized Lighting Fixtures',#7751,$,$); +#7785=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 21 11','Lighting Bollards',#7784,$,$); +#7786=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 21 13','Lighting Poles',#7784,$,$); +#7787=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 21 15','Lighting Posts',#7784,$,$); +#7788=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 21 17','Buried Uplights',#7784,$,$); +#7789=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 21 19','Floodlight Fixtures',#7784,$,$); +#7790=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 21 21','Spotlight Fixtures',#7784,$,$); +#7791=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 21 21 11','Focus Spotlight Fixture',#7790,$,$); +#7792=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 21 21 13','Follow Spotlight Fixture',#7790,$,$); +#7793=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 21 21 15','Spotlight Bank Fixture',#7790,$,$); +#7794=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 21 21 17','Pin Spotlight Fixture',#7790,$,$); +#7795=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 21 23','Street and Roadway Lighting Fixtures',#7784,$,$); +#7796=IFCCLASSIFICATIONREFERENCE($,'23-35 47 11 21 25','Aircraft Paving Lighting Fixtures',#7784,$,$); +#7797=IFCCLASSIFICATIONREFERENCE($,'23-35 47 13','Emergency Lighting',#7750,$,$); +#7798=IFCCLASSIFICATIONREFERENCE($,'23-35 47 13 11','Hard Wired Emergency Lighting',#7797,$,$); +#7799=IFCCLASSIFICATIONREFERENCE($,'23-35 47 13 13','Emergency Lighting With Battery Backup',#7797,$,$); +#7800=IFCCLASSIFICATIONREFERENCE($,'23-35 47 13 15','Passive Emergency Lighting Strips',#7797,$,$); +#7801=IFCCLASSIFICATIONREFERENCE($,'23-35 47 13 17','Emergency Lighting Strobe',#7797,$,$); +#7802=IFCCLASSIFICATIONREFERENCE($,'23-35 47 15','Exit Illuminated Signs',#7750,$,$); +#7803=IFCCLASSIFICATIONREFERENCE($,'23-35 47 15 11','Battery Backup Exit Illuminated Signs',#7802,$,$); +#7804=IFCCLASSIFICATIONREFERENCE($,'23-35 47 15 13','Hard Wired Backup Exit Illuminated Signs',#7802,$,$); +#7805=IFCCLASSIFICATIONREFERENCE($,'23-35 47 15 15','Self Illuminated Exit Illuminated Signs',#7802,$,$); +#7806=IFCCLASSIFICATIONREFERENCE($,'23-35 47 17','Fiber Optic Lighting',#7750,$,$); +#7807=IFCCLASSIFICATIONREFERENCE($,'23-35 47 19','Communication Lighting Specialties',#7750,$,$); +#7808=IFCCLASSIFICATIONREFERENCE($,'23-35 47 19 11','Illuminated Signs Boards',#7807,$,$); +#7809=IFCCLASSIFICATIONREFERENCE($,'23-35 47 21','Accessories for Lighting',#7750,$,$); +#7810=IFCCLASSIFICATIONREFERENCE($,'23-35 47 21 11','Lampholders',#7809,$,$); +#7811=IFCCLASSIFICATIONREFERENCE($,'23-35 47 21 13','Lighting Diffusers',#7809,$,$); +#7812=IFCCLASSIFICATIONREFERENCE($,'23-35 47 21 15','Lighting Ballasts',#7809,$,$); +#7813=IFCCLASSIFICATIONREFERENCE($,'23-35 47 21 17','Lighting Tracks',#7809,$,$); +#7814=IFCCLASSIFICATIONREFERENCE($,'23-35 47 21 19','Lampshades',#7809,$,$); +#7815=IFCCLASSIFICATIONREFERENCE($,'23-35 47 23','Lamps',#7750,$,$); +#7816=IFCCLASSIFICATIONREFERENCE($,'23-35 47 23 11','Halogen Lamps',#7815,$,$); +#7817=IFCCLASSIFICATIONREFERENCE($,'23-35 47 23 13','Incandescent Lamps',#7815,$,$); +#7818=IFCCLASSIFICATIONREFERENCE($,'23-35 47 23 15','Discharge Lamps',#7815,$,$); +#7819=IFCCLASSIFICATIONREFERENCE($,'23-35 47 23 15 11','Fluorescent Lamps',#7818,$,$); +#7820=IFCCLASSIFICATIONREFERENCE($,'23-35 47 23 15 13','Compact Fluorescent Lamps',#7818,$,$); +#7821=IFCCLASSIFICATIONREFERENCE($,'23-35 47 23 15 15','Sodium Vapor Lamps',#7818,$,$); +#7822=IFCCLASSIFICATIONREFERENCE($,'23-35 47 23 15 17','High Pressure Discharge Lamps',#7818,$,$); +#7823=IFCCLASSIFICATIONREFERENCE($,'23-35 47 23 17','Light Emitting Diode Lamps',#7815,$,$); +#7824=IFCCLASSIFICATIONREFERENCE($,'23-37 00 00','Information and Communication Specific Products and Equipment',#1606,$,$); +#7825=IFCCLASSIFICATIONREFERENCE($,'23-37 11 00','Information Technology and Telecommunications Ducting Wireways Components',#7824,$,$); +#7826=IFCCLASSIFICATIONREFERENCE($,'23-37 11 11','Communication Service Penetrations',#7825,$,$); +#7827=IFCCLASSIFICATIONREFERENCE($,'23-37 11 13','Communication Cable Trays',#7825,$,$); +#7828=IFCCLASSIFICATIONREFERENCE($,'23-37 11 15','Communication Racks',#7825,$,$); +#7829=IFCCLASSIFICATIONREFERENCE($,'23-37 11 15 11','Information Technology Racks',#7828,$,$); +#7830=IFCCLASSIFICATIONREFERENCE($,'23-37 11 15 13','Telephone Racks',#7828,$,$); +#7831=IFCCLASSIFICATIONREFERENCE($,'23-37 11 15 15','Fiber Optic Equipment',#7828,$,$); +#7832=IFCCLASSIFICATIONREFERENCE($,'23-37 11 15 15 11','Fiber Optic Cabinets',#7831,$,$); +#7833=IFCCLASSIFICATIONREFERENCE($,'23-37 11 15 15 13','Fiber Adapter Panels',#7831,$,$); +#7834=IFCCLASSIFICATIONREFERENCE($,'23-37 11 17','Communication Wireways',#7825,$,$); +#7835=IFCCLASSIFICATIONREFERENCE($,'23-37 11 17 11','Information Technology Wireways',#7834,$,$); +#7836=IFCCLASSIFICATIONREFERENCE($,'23-37 11 17 11 11','Underfloor Information Technology Wireways',#7835,$,$); +#7837=IFCCLASSIFICATIONREFERENCE($,'23-37 11 17 11 13','Vertical Information Technology Wire Raceways',#7835,$,$); +#7838=IFCCLASSIFICATIONREFERENCE($,'23-37 11 17 11 15','Horizontal Information Technology Wire Raceways',#7835,$,$); +#7839=IFCCLASSIFICATIONREFERENCE($,'23-37 11 17 13','Telecommunications Wireways',#7834,$,$); +#7840=IFCCLASSIFICATIONREFERENCE($,'23-37 11 17 13 11','Underfloor Telecommunications Wireways',#7839,$,$); +#7841=IFCCLASSIFICATIONREFERENCE($,'23-37 11 17 13 13','Vertical Telecommunications Wire Raceways',#7839,$,$); +#7842=IFCCLASSIFICATIONREFERENCE($,'23-37 11 17 13 15','Horizontal Telecommunications Wire Raceways',#7839,$,$); +#7843=IFCCLASSIFICATIONREFERENCE($,'23-37 11 17 15','Complete Visual Signaling',#7834,$,$); +#7844=IFCCLASSIFICATIONREFERENCE($,'23-37 11 17 15 11','Mechanical Signal Equipment',#7843,$,$); +#7845=IFCCLASSIFICATIONREFERENCE($,'23-37 13 00','Information Technology Equipment',#7824,$,$); +#7846=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11','Personal Computer Equipment',#7845,$,$); +#7847=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11 11','Desktop Personal Computers',#7846,$,$); +#7848=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11 13','Laptop Personal Computers',#7846,$,$); +#7849=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11 15','Tablet Personal Computers',#7846,$,$); +#7850=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11 17','Tower Stack Personal Computers',#7846,$,$); +#7851=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11 19','Workstation Personal Computers',#7846,$,$); +#7852=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11 21','Personal Digital Assistants',#7846,$,$); +#7853=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11 23','Internal Computing Components',#7846,$,$); +#7854=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11 23 11','Computer Processing Units',#7853,$,$); +#7855=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11 23 13','Computer Controller Cards',#7853,$,$); +#7856=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11 23 15','Computer Memory Cards',#7853,$,$); +#7857=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11 23 17','Personal Computer Modem Cards',#7853,$,$); +#7858=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11 23 19','Personal Computer Network Interface Cards',#7853,$,$); +#7859=IFCCLASSIFICATIONREFERENCE($,'23-37 13 11 23 21','Personal Computer Video Cards',#7853,$,$); +#7860=IFCCLASSIFICATIONREFERENCE($,'23-37 13 13','Personal Computer and Network Security Devices',#7845,$,$); +#7861=IFCCLASSIFICATIONREFERENCE($,'23-37 13 13 11','Computer Firewalls',#7860,$,$); +#7862=IFCCLASSIFICATIONREFERENCE($,'23-37 13 13 13','Computer Intrusion Detection Devices',#7860,$,$); +#7863=IFCCLASSIFICATIONREFERENCE($,'23-37 13 13 15','Computer Intrusion Protection Devices',#7860,$,$); +#7864=IFCCLASSIFICATIONREFERENCE($,'23-37 13 15','Local Area Network Devices',#7845,$,$); +#7865=IFCCLASSIFICATIONREFERENCE($,'23-37 13 15 11','Local Area Network Bridges',#7864,$,$); +#7866=IFCCLASSIFICATIONREFERENCE($,'23-37 13 15 13','Local Area Network Communication Hardware',#7864,$,$); +#7867=IFCCLASSIFICATIONREFERENCE($,'23-37 13 15 15','Local Area Network Disk Drives',#7864,$,$); +#7868=IFCCLASSIFICATIONREFERENCE($,'23-37 13 15 17','Local Area Network Hubs',#7864,$,$); +#7869=IFCCLASSIFICATIONREFERENCE($,'23-37 13 15 19','Local Area Network Load Balancers',#7864,$,$); +#7870=IFCCLASSIFICATIONREFERENCE($,'23-37 13 15 21','Local Area Network Routers',#7864,$,$); +#7871=IFCCLASSIFICATIONREFERENCE($,'23-37 13 15 23','Local Area Network Servers',#7864,$,$); +#7872=IFCCLASSIFICATIONREFERENCE($,'23-37 13 15 25','Local Area Network Switches',#7864,$,$); +#7873=IFCCLASSIFICATIONREFERENCE($,'23-37 13 15 27','Local Area Network Tape Drives',#7864,$,$); +#7874=IFCCLASSIFICATIONREFERENCE($,'23-37 13 15 29','Local Area Network Wireless Devices',#7864,$,$); +#7875=IFCCLASSIFICATIONREFERENCE($,'23-37 13 17','Wide Area Network Devices',#7845,$,$); +#7876=IFCCLASSIFICATIONREFERENCE($,'23-37 13 17 11','Wide Area Network Bridges',#7875,$,$); +#7877=IFCCLASSIFICATIONREFERENCE($,'23-37 13 17 13','Wide Area Network Communication Hardware',#7875,$,$); +#7878=IFCCLASSIFICATIONREFERENCE($,'23-37 13 17 15','Wide Area Network Disk Drives',#7875,$,$); +#7879=IFCCLASSIFICATIONREFERENCE($,'23-37 13 17 17','Wide Area Network Hubs',#7875,$,$); +#7880=IFCCLASSIFICATIONREFERENCE($,'23-37 13 17 19','Wide Area Network Load Balancers',#7875,$,$); +#7881=IFCCLASSIFICATIONREFERENCE($,'23-37 13 17 21','Wide Area Network Routers',#7875,$,$); +#7882=IFCCLASSIFICATIONREFERENCE($,'23-37 13 17 23','Wide Area Network Servers',#7875,$,$); +#7883=IFCCLASSIFICATIONREFERENCE($,'23-37 13 17 25','Wide Area Network Switches',#7875,$,$); +#7884=IFCCLASSIFICATIONREFERENCE($,'23-37 13 17 27','Wide Area Network Tape Drives',#7875,$,$); +#7885=IFCCLASSIFICATIONREFERENCE($,'23-37 13 17 29','Wide Area Network Wireless Devices',#7875,$,$); +#7886=IFCCLASSIFICATIONREFERENCE($,'23-37 13 19','Computer Storage Devices',#7845,$,$); +#7887=IFCCLASSIFICATIONREFERENCE($,'23-37 13 19 11','Computer Optic Drives',#7886,$,$); +#7888=IFCCLASSIFICATIONREFERENCE($,'23-37 13 19 11 11','Compact Disk Drives',#7887,$,$); +#7889=IFCCLASSIFICATIONREFERENCE($,'23-37 13 19 11 13','Digital Video Disc Drives',#7887,$,$); +#7890=IFCCLASSIFICATIONREFERENCE($,'23-37 13 19 11 15','Combination Compact Disk and Digital Video Disc Drives',#7887,$,$); +#7891=IFCCLASSIFICATIONREFERENCE($,'23-37 13 19 13','Hard Disk Drives',#7886,$,$); +#7892=IFCCLASSIFICATIONREFERENCE($,'23-37 13 19 15','Flash Memory Drives',#7886,$,$); +#7893=IFCCLASSIFICATIONREFERENCE($,'23-37 13 19 17','Computer Tape Drives',#7886,$,$); +#7894=IFCCLASSIFICATIONREFERENCE($,'23-37 13 21','Computer Monitors',#7845,$,$); +#7895=IFCCLASSIFICATIONREFERENCE($,'23-37 13 21 11','Computer Liquid Crystal Display Monitors',#7894,$,$); +#7896=IFCCLASSIFICATIONREFERENCE($,'23-37 13 21 13','Computer Catho Ray Tube Monitors',#7894,$,$); +#7897=IFCCLASSIFICATIONREFERENCE($,'23-37 13 23','Computer Printers',#7845,$,$); +#7898=IFCCLASSIFICATIONREFERENCE($,'23-37 13 23 11','Computer Laser Printers',#7897,$,$); +#7899=IFCCLASSIFICATIONREFERENCE($,'23-37 13 23 13','Computer Inkjet Printers',#7897,$,$); +#7900=IFCCLASSIFICATIONREFERENCE($,'23-37 13 23 15','Computer Plotter Printers',#7897,$,$); +#7901=IFCCLASSIFICATIONREFERENCE($,'23-37 13 25','Computer Scanners',#7845,$,$); +#7902=IFCCLASSIFICATIONREFERENCE($,'23-37 13 27','Computer Video Conferencing Equipment',#7845,$,$); +#7903=IFCCLASSIFICATIONREFERENCE($,'23-37 15 00','Audio Visual Equipment',#7824,$,$); +#7904=IFCCLASSIFICATIONREFERENCE($,'23-37 15 11','Cameras',#7903,$,$); +#7905=IFCCLASSIFICATIONREFERENCE($,'23-37 15 11 11','Analog Cameras',#7904,$,$); +#7906=IFCCLASSIFICATIONREFERENCE($,'23-37 15 11 13','Digital Cameras',#7904,$,$); +#7907=IFCCLASSIFICATIONREFERENCE($,'23-37 15 13','Camera Recorders',#7903,$,$); +#7908=IFCCLASSIFICATIONREFERENCE($,'23-37 15 13 11','Digital Camcorders',#7907,$,$); +#7909=IFCCLASSIFICATIONREFERENCE($,'23-37 15 13 13','Film Camcorders',#7907,$,$); +#7910=IFCCLASSIFICATIONREFERENCE($,'23-37 15 15','Digital Music Players',#7903,$,$); +#7911=IFCCLASSIFICATIONREFERENCE($,'23-37 15 17','Projection Equipment',#7903,$,$); +#7912=IFCCLASSIFICATIONREFERENCE($,'23-37 15 17 11','Projection Screens',#7911,$,$); +#7913=IFCCLASSIFICATIONREFERENCE($,'23-37 15 17 13','Projection Screen Stands',#7911,$,$); +#7914=IFCCLASSIFICATIONREFERENCE($,'23-37 15 19','Video Projectors',#7903,$,$); +#7915=IFCCLASSIFICATIONREFERENCE($,'23-37 15 19 11','Video Slide Projectors',#7914,$,$); +#7916=IFCCLASSIFICATIONREFERENCE($,'23-37 15 19 13','Video Overhead Projectors',#7914,$,$); +#7917=IFCCLASSIFICATIONREFERENCE($,'23-37 15 19 15','Video Film Projectors',#7914,$,$); +#7918=IFCCLASSIFICATIONREFERENCE($,'23-37 15 19 17','Video Slide Projectors',#7914,$,$); +#7919=IFCCLASSIFICATIONREFERENCE($,'23-37 15 19 19','Video Digital Projectors',#7914,$,$); +#7920=IFCCLASSIFICATIONREFERENCE($,'23-37 15 21','Audio Visual Recorders',#7903,$,$); +#7921=IFCCLASSIFICATIONREFERENCE($,'23-37 15 21 11','Audio Recorders',#7920,$,$); +#7922=IFCCLASSIFICATIONREFERENCE($,'23-37 15 21 13','Video Recorders',#7920,$,$); +#7923=IFCCLASSIFICATIONREFERENCE($,'23-37 15 21 15','Audio Video Recorders',#7920,$,$); +#7924=IFCCLASSIFICATIONREFERENCE($,'23-37 15 23','Stereo Equipment',#7903,$,$); +#7925=IFCCLASSIFICATIONREFERENCE($,'23-37 15 23 11','Stereo Amplifiers',#7924,$,$); +#7926=IFCCLASSIFICATIONREFERENCE($,'23-37 15 23 13','Stereo Patch Panels',#7924,$,$); +#7927=IFCCLASSIFICATIONREFERENCE($,'23-37 15 23 15','Stereo Speakers',#7924,$,$); +#7928=IFCCLASSIFICATIONREFERENCE($,'23-37 15 25','Televisions',#7903,$,$); +#7929=IFCCLASSIFICATIONREFERENCE($,'23-37 15 25 11','Cathoray Tube Televisions',#7928,$,$); +#7930=IFCCLASSIFICATIONREFERENCE($,'23-37 15 25 13','Liquid Crystal Display Televisions',#7928,$,$); +#7931=IFCCLASSIFICATIONREFERENCE($,'23-37 15 25 15','Plasma Display Televisions',#7928,$,$); +#7932=IFCCLASSIFICATIONREFERENCE($,'23-37 15 25 17','Projection Screen Televisions',#7928,$,$); +#7933=IFCCLASSIFICATIONREFERENCE($,'23-37 15 25 19','Television Mounts',#7928,$,$); +#7934=IFCCLASSIFICATIONREFERENCE($,'23-37 15 27','Video Recording Equipment',#7903,$,$); +#7935=IFCCLASSIFICATIONREFERENCE($,'23-37 15 29','Audio Equipment',#7903,$,$); +#7936=IFCCLASSIFICATIONREFERENCE($,'23-37 15 29 11','Sound Reinforcement Equipment',#7935,$,$); +#7937=IFCCLASSIFICATIONREFERENCE($,'23-37 15 29 11 11','Microphones',#7936,$,$); +#7938=IFCCLASSIFICATIONREFERENCE($,'23-37 15 29 11 13','Loudspeakers',#7936,$,$); +#7939=IFCCLASSIFICATIONREFERENCE($,'23-37 15 29 11 15','Sound Amplifiers',#7936,$,$); +#7940=IFCCLASSIFICATIONREFERENCE($,'23-37 15 29 11 17','Audio Equalizers',#7936,$,$); +#7941=IFCCLASSIFICATIONREFERENCE($,'23-37 15 29 13','Headphones',#7935,$,$); +#7942=IFCCLASSIFICATIONREFERENCE($,'23-37 15 29 15','Audio Reproducing Units',#7935,$,$); +#7943=IFCCLASSIFICATIONREFERENCE($,'23-37 17 00','Audio Information Equipment',#7824,$,$); +#7944=IFCCLASSIFICATIONREFERENCE($,'23-37 17 11','Sound Devices',#7943,$,$); +#7945=IFCCLASSIFICATIONREFERENCE($,'23-37 17 13','Signal Devices',#7943,$,$); +#7946=IFCCLASSIFICATIONREFERENCE($,'23-37 17 13 11','Bells',#7945,$,$); +#7947=IFCCLASSIFICATIONREFERENCE($,'23-37 17 13 13','Carillons',#7945,$,$); +#7948=IFCCLASSIFICATIONREFERENCE($,'23-37 17 13 15','Sirens',#7945,$,$); +#7949=IFCCLASSIFICATIONREFERENCE($,'23-37 17 13 17','Aerials',#7945,$,$); +#7950=IFCCLASSIFICATIONREFERENCE($,'23-37 17 13 19','Speakers',#7945,$,$); +#7951=IFCCLASSIFICATIONREFERENCE($,'23-37 17 15','Public Address Equipment',#7943,$,$); +#7952=IFCCLASSIFICATIONREFERENCE($,'23-37 19 00','Visual Information Systems',#7824,$,$); +#7953=IFCCLASSIFICATIONREFERENCE($,'23-37 19 11','Cathode Ray Tube (CRT) Video Monitors',#7952,$,$); +#7954=IFCCLASSIFICATIONREFERENCE($,'23-37 19 13','Liquid Crystal Display (LCD) Video Monitors',#7952,$,$); +#7955=IFCCLASSIFICATIONREFERENCE($,'23-37 19 15','Plasma Video Monitors',#7952,$,$); +#7956=IFCCLASSIFICATIONREFERENCE($,'23-37 19 17','Video Walls',#7952,$,$); +#7957=IFCCLASSIFICATIONREFERENCE($,'23-37 21 00','Audio Visual Systems',#7824,$,$); +#7958=IFCCLASSIFICATIONREFERENCE($,'23-37 21 11','Broadcasting Receiving Equipment',#7957,$,$); +#7959=IFCCLASSIFICATIONREFERENCE($,'23-37 21 13','Film Projectors',#7957,$,$); +#7960=IFCCLASSIFICATIONREFERENCE($,'23-37 21 15','Data Multi Media Projectors',#7957,$,$); +#7961=IFCCLASSIFICATIONREFERENCE($,'23-37 21 17','Video Reproduction',#7957,$,$); +#7962=IFCCLASSIFICATIONREFERENCE($,'23-37 23 00','Telecommunications Equipment',#7824,$,$); +#7963=IFCCLASSIFICATIONREFERENCE($,'23-37 23 11','Wireless Phone Equipment',#7962,$,$); +#7964=IFCCLASSIFICATIONREFERENCE($,'23-37 23 11 11','Wireless Phones',#7963,$,$); +#7965=IFCCLASSIFICATIONREFERENCE($,'23-37 23 11 13','Wireless Phone Chargers',#7963,$,$); +#7966=IFCCLASSIFICATIONREFERENCE($,'23-37 23 13','Telephones',#7962,$,$); +#7967=IFCCLASSIFICATIONREFERENCE($,'23-37 23 13 11','Single Line Telephones',#7966,$,$); +#7968=IFCCLASSIFICATIONREFERENCE($,'23-37 23 13 13','Multiple Line Telephones',#7966,$,$); +#7969=IFCCLASSIFICATIONREFERENCE($,'23-37 23 15','Telephone Equipment',#7962,$,$); +#7970=IFCCLASSIFICATIONREFERENCE($,'23-37 23 15 11','Private Branch Exchanges',#7969,$,$); +#7971=IFCCLASSIFICATIONREFERENCE($,'23-37 23 15 13','Telephone Patch Panels',#7969,$,$); +#7972=IFCCLASSIFICATIONREFERENCE($,'23-37 23 17','Intercom Equipment',#7962,$,$); +#7973=IFCCLASSIFICATIONREFERENCE($,'23-37 23 17 11','Intercoms',#7972,$,$); +#7974=IFCCLASSIFICATIONREFERENCE($,'23-37 23 17 13','Door Entry Telephones',#7972,$,$); +#7975=IFCCLASSIFICATIONREFERENCE($,'23-37 23 19','Radio Broadcast Equipment',#7962,$,$); +#7976=IFCCLASSIFICATIONREFERENCE($,'23-37 23 19 11','Radio Booths',#7975,$,$); +#7977=IFCCLASSIFICATIONREFERENCE($,'23-37 23 19 11 11','Radio Broadcast Booths',#7976,$,$); +#7978=IFCCLASSIFICATIONREFERENCE($,'23-37 23 19 11 13','Radio Recording Booths',#7976,$,$); +#7979=IFCCLASSIFICATIONREFERENCE($,'23-37 23 19 13','Radio Broadcast Transmitters',#7975,$,$); +#7980=IFCCLASSIFICATIONREFERENCE($,'23-37 23 19 15','Radio Broadcast Receivers',#7975,$,$); +#7981=IFCCLASSIFICATIONREFERENCE($,'23-37 23 19 17','Radio Communication Base Stations',#7975,$,$); +#7982=IFCCLASSIFICATIONREFERENCE($,'23-37 23 19 19','Radio Communication Call Microphones',#7975,$,$); +#7983=IFCCLASSIFICATIONREFERENCE($,'23-37 23 19 21','Radio Broadcast Transmission Towers',#7975,$,$); +#7984=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21','Radio Communication Equipment',#7962,$,$); +#7985=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 11','Infra Red Radio Communication Equipment',#7984,$,$); +#7986=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 11 11','Infra Red Radio Communication Receivers',#7985,$,$); +#7987=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 11 13','Infra Red Radio Communication Transmitters',#7985,$,$); +#7988=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 11 15','Infra Red Radio Communication Transmitter Receivers',#7985,$,$); +#7989=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 13','Satellite Radio Communication Equipment',#7984,$,$); +#7990=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 13 11','Satellite Radio Communication Transmitters',#7989,$,$); +#7991=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 13 13','Satellite Radio Communication Transmitter Receivers',#7989,$,$); +#7992=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 13 15','Satellite Radio Communications Receivers',#7989,$,$); +#7993=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 15','Wireless Radio Communication Equipment',#7984,$,$); +#7994=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 15 11','Wireless Radio Communication Receivers',#7993,$,$); +#7995=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 15 13','Wireless Radio Communication Transmitters',#7993,$,$); +#7996=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 15 15','Wireless Radio Communication Transmitter Receivers',#7993,$,$); +#7997=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 17','Radio Communication Antenna Towers',#7984,$,$); +#7998=IFCCLASSIFICATIONREFERENCE($,'23-37 23 21 19','Radio Communication Transmission Towers',#7984,$,$); +#7999=IFCCLASSIFICATIONREFERENCE($,'23-37 23 23','Satellite Communication Equipment',#7962,$,$); +#8000=IFCCLASSIFICATIONREFERENCE($,'23-37 23 23 11','Satellite Communication Dishes',#7999,$,$); +#8001=IFCCLASSIFICATIONREFERENCE($,'23-37 25 00','Broadcasting Communications Equipment',#7824,$,$); +#8002=IFCCLASSIFICATIONREFERENCE($,'23-37 25 11','Broadcasting Communication Circuits',#8001,$,$); +#8003=IFCCLASSIFICATIONREFERENCE($,'23-37 25 13','Broadcasting Intercommunication Equipment',#8001,$,$); +#8004=IFCCLASSIFICATIONREFERENCE($,'23-37 25 15','Broadcasting Communication and Data Processing Equipment',#8001,$,$); +#8005=IFCCLASSIFICATIONREFERENCE($,'23-37 25 17','Broadcasting Cable Transmission and Reception Equipment',#8001,$,$); +#8006=IFCCLASSIFICATIONREFERENCE($,'23-37 25 17 11','Broadcasting Cable Transmission and Reception Amplifiers',#8005,$,$); +#8007=IFCCLASSIFICATIONREFERENCE($,'23-37 25 17 13','Broadcasting Cable Transmission and Reception Modulators',#8005,$,$); +#8008=IFCCLASSIFICATIONREFERENCE($,'23-37 25 17 15','Broadcasting Cable Transmission and Reception Control Equipment',#8005,$,$); +#8009=IFCCLASSIFICATIONREFERENCE($,'23-37 25 19','Broadcast Transmission and Reception Equipment',#8001,$,$); +#8010=IFCCLASSIFICATIONREFERENCE($,'23-37 25 19 11','Broadcast Transmitters',#8009,$,$); +#8011=IFCCLASSIFICATIONREFERENCE($,'23-37 25 19 13','Broadcast Antennas',#8009,$,$); +#8012=IFCCLASSIFICATIONREFERENCE($,'23-37 25 19 15','Broadcast Amplifiers',#8009,$,$); +#8013=IFCCLASSIFICATIONREFERENCE($,'23-37 25 19 17','Broadcast Control Equipment',#8009,$,$); +#8014=IFCCLASSIFICATIONREFERENCE($,'23-37 25 21','Broadcasting Microwave Transmission and Reception Equipment',#8001,$,$); +#8015=IFCCLASSIFICATIONREFERENCE($,'23-37 25 21 11','Broadcasting Microwave Transmitters',#8014,$,$); +#8016=IFCCLASSIFICATIONREFERENCE($,'23-37 25 21 13','Broadcasting Microwave Antennas',#8014,$,$); +#8017=IFCCLASSIFICATIONREFERENCE($,'23-37 25 21 15','Broadcasting Satellite Dishes',#8014,$,$); +#8018=IFCCLASSIFICATIONREFERENCE($,'23-37 25 21 17','Broadcasting Microwave Amplifiers',#8014,$,$); +#8019=IFCCLASSIFICATIONREFERENCE($,'23-37 25 21 19','Broadcasting Microwave Receivers',#8014,$,$); +#8020=IFCCLASSIFICATIONREFERENCE($,'23-37 25 23','Broadcasting Equipment',#8001,$,$); +#8021=IFCCLASSIFICATIONREFERENCE($,'23-37 25 23 11','Television Broadcasting Equipment',#8020,$,$); +#8022=IFCCLASSIFICATIONREFERENCE($,'23-37 25 23 13','Multimedia Broadcasting Equipment',#8020,$,$); +#8023=IFCCLASSIFICATIONREFERENCE($,'23-37 25 23 15','Broadcasting Light Signals',#8020,$,$); +#8024=IFCCLASSIFICATIONREFERENCE($,'23-37 27 00','Emergency Communications',#7824,$,$); +#8025=IFCCLASSIFICATIONREFERENCE($,'23-37 27 11','Duress Notification Devices',#8024,$,$); +#8026=IFCCLASSIFICATIONREFERENCE($,'23-37 27 13','Mass Notification Systems',#8024,$,$); +#8027=IFCCLASSIFICATIONREFERENCE($,'23-37 27 13 11','Emergency Notification Devices',#8026,$,$); +#8028=IFCCLASSIFICATIONREFERENCE($,'23-37 27 13 13','Imminent Danger Notification Devices',#8026,$,$); +#8029=IFCCLASSIFICATIONREFERENCE($,'23-37 27 15','Intercoms',#8024,$,$); +#8030=IFCCLASSIFICATIONREFERENCE($,'23-37 27 15 11','Audio Intercoms',#8029,$,$); +#8031=IFCCLASSIFICATIONREFERENCE($,'23-37 27 15 13','Audio Visual Intercoms',#8029,$,$); +#8032=IFCCLASSIFICATIONREFERENCE($,'23-37 27 17','Emergency Call Equipment',#8024,$,$); +#8033=IFCCLASSIFICATIONREFERENCE($,'23-37 27 17 11','Call Systems for the Disabled',#8032,$,$); +#8034=IFCCLASSIFICATIONREFERENCE($,'23-37 27 17 13','Nurse Call Equipment',#8032,$,$); +#8035=IFCCLASSIFICATIONREFERENCE($,'23-39 00 00','Utility and Transportation Products',#1606,$,$); +#8036=IFCCLASSIFICATIONREFERENCE($,'23-39 11 00','Roadway Monitoring and Control',#8035,$,$); +#8037=IFCCLASSIFICATIONREFERENCE($,'23-39 11 11','Traffic Safety Barriers and Protections',#8036,$,$); +#8038=IFCCLASSIFICATIONREFERENCE($,'23-39 11 11 11','Safety Barriers',#8037,$,$); +#8039=IFCCLASSIFICATIONREFERENCE($,'23-39 11 11 11 11','Crash Barriers ( including Impact Attenuating Devices)',#8038,$,$); +#8040=IFCCLASSIFICATIONREFERENCE($,'23-39 11 11 11 13','Median Barriers',#8038,$,$); +#8041=IFCCLASSIFICATIONREFERENCE($,'23-39 11 11 11 15','Guardrails',#8038,$,$); +#8042=IFCCLASSIFICATIONREFERENCE($,'23-39 11 11 13','Noise Barriers',#8037,$,$); +#8043=IFCCLASSIFICATIONREFERENCE($,'23-39 11 11 15','Traffic Barriers',#8037,$,$); +#8044=IFCCLASSIFICATIONREFERENCE($,'23-39 11 11 15 11','Traffic Delineators',#8043,$,$); +#8045=IFCCLASSIFICATIONREFERENCE($,'23-39 11 11 17','Traffic Control',#8037,$,$); +#8046=IFCCLASSIFICATIONREFERENCE($,'23-39 11 11 17 11','Traffic Speed Bumps',#8045,$,$); +#8047=IFCCLASSIFICATIONREFERENCE($,'23-39 11 11 19','Roadway Curbs',#8037,$,$); +#8048=IFCCLASSIFICATIONREFERENCE($,'23-39 11 11 21','Roadway Gutters',#8037,$,$); +#8049=IFCCLASSIFICATIONREFERENCE($,'23-39 11 11 23','Roadway Cattle Guards',#8037,$,$); +#8050=IFCCLASSIFICATIONREFERENCE($,'23-39 11 13','Roadway Signage',#8036,$,$); +#8051=IFCCLASSIFICATIONREFERENCE($,'23-39 11 15','Roadway Markers',#8036,$,$); +#8052=IFCCLASSIFICATIONREFERENCE($,'23-39 11 15 11','Roadway Surface Markings',#8051,$,$); +#8053=IFCCLASSIFICATIONREFERENCE($,'23-39 11 15 13','Roadway Reflectors',#8051,$,$); +#8054=IFCCLASSIFICATIONREFERENCE($,'23-39 11 15 15','Traffic Cones',#8051,$,$); +#8055=IFCCLASSIFICATIONREFERENCE($,'23-39 11 15 17','Traffic Signals',#8051,$,$); +#8056=IFCCLASSIFICATIONREFERENCE($,'23-39 11 15 19','Traffic Monitoring Equipment',#8051,$,$); +#8057=IFCCLASSIFICATIONREFERENCE($,'23-39 11 15 21','Roadway Mirrors',#8051,$,$); +#8058=IFCCLASSIFICATIONREFERENCE($,'23-39 11 15 23','Traffic Cameras',#8051,$,$); +#8059=IFCCLASSIFICATIONREFERENCE($,'23-39 11 15 25','Traffic Detectors and Sensors',#8051,$,$); +#8060=IFCCLASSIFICATIONREFERENCE($,'23-39 11 17','Vehicle Control Barriers',#8036,$,$); +#8061=IFCCLASSIFICATIONREFERENCE($,'23-39 11 17 11','Anti Ram Planters',#8060,$,$); +#8062=IFCCLASSIFICATIONREFERENCE($,'23-39 11 17 13','Jersey Barriers',#8060,$,$); +#8063=IFCCLASSIFICATIONREFERENCE($,'23-39 11 17 15','Active Tire Shredders',#8060,$,$); +#8064=IFCCLASSIFICATIONREFERENCE($,'23-39 11 17 17','Passive Tire Shredders',#8060,$,$); +#8065=IFCCLASSIFICATIONREFERENCE($,'23-39 11 19','Bollards',#8036,$,$); +#8066=IFCCLASSIFICATIONREFERENCE($,'23-39 11 19 11','Active Anti Ram Bollards',#8065,$,$); +#8067=IFCCLASSIFICATIONREFERENCE($,'23-39 11 19 13','Passive Anti Ram Bollards',#8065,$,$); +#8068=IFCCLASSIFICATIONREFERENCE($,'23-39 11 19 15','Architectural Bollards',#8065,$,$); +#8069=IFCCLASSIFICATIONREFERENCE($,'23-39 13 00','Tunnels and Bridges',#8035,$,$); +#8070=IFCCLASSIFICATIONREFERENCE($,'23-39 13 11','Tunnels',#8069,$,$); +#8071=IFCCLASSIFICATIONREFERENCE($,'23-39 13 11 11','Tunnel Shafts',#8070,$,$); +#8072=IFCCLASSIFICATIONREFERENCE($,'23-39 13 11 13','Tunnel Segments',#8070,$,$); +#8073=IFCCLASSIFICATIONREFERENCE($,'23-39 13 11 15','Tunnel Linings',#8070,$,$); +#8074=IFCCLASSIFICATIONREFERENCE($,'23-39 13 11 17','Tunnel Grouting',#8070,$,$); +#8075=IFCCLASSIFICATIONREFERENCE($,'23-39 13 11 17 11','Earth Stabilization Chemical Grouting',#8074,$,$); +#8076=IFCCLASSIFICATIONREFERENCE($,'23-39 13 11 17 13','Rock Seam Pressure Grouting',#8074,$,$); +#8077=IFCCLASSIFICATIONREFERENCE($,'23-39 13 11 17 15','Tunnel Liner Grouting',#8074,$,$); +#8078=IFCCLASSIFICATIONREFERENCE($,'23-39 13 11 19','Microtunneling',#8070,$,$); +#8079=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13','Bridges',#8069,$,$); +#8080=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 11','Prefabricated Bridges',#8079,$,$); +#8081=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 13','Bridge Beams',#8079,$,$); +#8082=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 15','Bridge Trusses',#8079,$,$); +#8083=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 17','Bridge Cable',#8079,$,$); +#8084=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 19','Bridge Bearings',#8079,$,$); +#8085=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 19 11','Fixed Bridge Bearings',#8084,$,$); +#8086=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 19 13','Expansion Bridge Bearings',#8084,$,$); +#8087=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 19 15','Multi Rotational Bridge Bearings',#8084,$,$); +#8088=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 21','Bridge Movable Mechanism',#8079,$,$); +#8089=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 23','Bridge Decking',#8079,$,$); +#8090=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 25','Bridge Drainage',#8079,$,$); +#8091=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 27','Bridge Safety Barriers',#8079,$,$); +#8092=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 27 11','Shock Absorbers',#8091,$,$); +#8093=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 27 13','Bridge Parapets',#8091,$,$); +#8094=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 27 15','Bridge Railings',#8091,$,$); +#8095=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 29','Bridge Expansion Joints',#8079,$,$); +#8096=IFCCLASSIFICATIONREFERENCE($,'23-39 13 13 29 11','Bridge Expansion Joint Assemblies',#8095,$,$); +#8097=IFCCLASSIFICATIONREFERENCE($,'23-39 15 00','Railways',#8035,$,$); +#8098=IFCCLASSIFICATIONREFERENCE($,'23-39 15 11','Railway Track Equipment',#8097,$,$); +#8099=IFCCLASSIFICATIONREFERENCE($,'23-39 15 11 11','Railway Ties',#8098,$,$); +#8100=IFCCLASSIFICATIONREFERENCE($,'23-39 15 11 11 11','Railway Concrete Ties',#8099,$,$); +#8101=IFCCLASSIFICATIONREFERENCE($,'23-39 15 11 11 13','Railway Wood Ties',#8099,$,$); +#8102=IFCCLASSIFICATIONREFERENCE($,'23-39 15 11 13','Railway Rails',#8098,$,$); +#8103=IFCCLASSIFICATIONREFERENCE($,'23-39 15 11 15','Railway Turnouts',#8098,$,$); +#8104=IFCCLASSIFICATIONREFERENCE($,'23-39 15 11 17','Railway Bumpers',#8098,$,$); +#8105=IFCCLASSIFICATIONREFERENCE($,'23-39 15 13','Railway Platform Components',#8097,$,$); +#8106=IFCCLASSIFICATIONREFERENCE($,'23-39 15 15','Railway Electrification Equipment',#8097,$,$); +#8107=IFCCLASSIFICATIONREFERENCE($,'23-39 15 15 11','Railway Surge Arresters',#8106,$,$); +#8108=IFCCLASSIFICATIONREFERENCE($,'23-39 15 15 13','Railway Traction Lines',#8106,$,$); +#8109=IFCCLASSIFICATIONREFERENCE($,'23-39 15 15 13 11','Railway Traction Line Pylons',#8108,$,$); +#8110=IFCCLASSIFICATIONREFERENCE($,'23-39 15 17','Railway Monitoring and Control',#8097,$,$); +#8111=IFCCLASSIFICATIONREFERENCE($,'23-39 15 17 11','Railway Signaling Devices',#8110,$,$); +#8112=IFCCLASSIFICATIONREFERENCE($,'23-39 15 17 13','Railway Control Instrumentation',#8110,$,$); +#8113=IFCCLASSIFICATIONREFERENCE($,'23-39 15 19','Railway Locomotives',#8097,$,$); +#8114=IFCCLASSIFICATIONREFERENCE($,'23-39 15 19 11','Railway Diesel Locomotives',#8113,$,$); +#8115=IFCCLASSIFICATIONREFERENCE($,'23-39 15 19 13','Railway Electric Locomotives',#8113,$,$); +#8116=IFCCLASSIFICATIONREFERENCE($,'23-39 15 21','Railway Cars',#8097,$,$); +#8117=IFCCLASSIFICATIONREFERENCE($,'23-39 15 21 11','Railway Passenger Cars',#8116,$,$); +#8118=IFCCLASSIFICATIONREFERENCE($,'23-39 15 21 13','Railway Sleeper Cars',#8116,$,$); +#8119=IFCCLASSIFICATIONREFERENCE($,'23-39 15 21 15','Railway Baggage Cars',#8116,$,$); +#8120=IFCCLASSIFICATIONREFERENCE($,'23-39 15 21 17','Railway Diner Cars',#8116,$,$); +#8121=IFCCLASSIFICATIONREFERENCE($,'23-39 15 21 19','Railway Freight Cars',#8116,$,$); +#8122=IFCCLASSIFICATIONREFERENCE($,'23-39 15 21 19 11','Railway Box Cars',#8121,$,$); +#8123=IFCCLASSIFICATIONREFERENCE($,'23-39 15 21 19 13','Railway Coal Cars',#8121,$,$); +#8124=IFCCLASSIFICATIONREFERENCE($,'23-39 15 21 19 15','Railway Vehicle Carrier Cars',#8121,$,$); +#8125=IFCCLASSIFICATIONREFERENCE($,'23-39 15 21 21','Railway Tanker Cars',#8116,$,$); +#8126=IFCCLASSIFICATIONREFERENCE($,'23-39 15 21 23','Railway Car Equipment',#8116,$,$); +#8127=IFCCLASSIFICATIONREFERENCE($,'23-39 15 21 23 11','Railway Car Bumpers',#8126,$,$); +#8128=IFCCLASSIFICATIONREFERENCE($,'23-39 15 21 23 13','Railway Car Electrical Connectors',#8126,$,$); +#8129=IFCCLASSIFICATIONREFERENCE($,'23-39 17 00','Funiculars',#8035,$,$); +#8130=IFCCLASSIFICATIONREFERENCE($,'23-39 17 11','Cable Trams',#8129,$,$); +#8131=IFCCLASSIFICATIONREFERENCE($,'23-39 17 13','Cable Cars',#8129,$,$); +#8132=IFCCLASSIFICATIONREFERENCE($,'23-39 17 15','Funicular Cable Rails',#8129,$,$); +#8133=IFCCLASSIFICATIONREFERENCE($,'23-39 17 17','Funicular Cables',#8129,$,$); +#8134=IFCCLASSIFICATIONREFERENCE($,'23-39 17 19','Aerial Tramways',#8129,$,$); +#8135=IFCCLASSIFICATIONREFERENCE($,'23-39 17 21','Chair Lifts',#8129,$,$); +#8136=IFCCLASSIFICATIONREFERENCE($,'23-39 17 23','Ski Lifts',#8129,$,$); +#8137=IFCCLASSIFICATIONREFERENCE($,'23-39 17 23 11','Ski Pole Lifts',#8136,$,$); +#8138=IFCCLASSIFICATIONREFERENCE($,'23-39 17 23 13','Ski Chair Lifts',#8136,$,$); +#8139=IFCCLASSIFICATIONREFERENCE($,'23-39 19 00','Aviation Equipment',#8035,$,$); +#8140=IFCCLASSIFICATIONREFERENCE($,'23-39 19 11','Aviation Monitoring and Control',#8139,$,$); +#8141=IFCCLASSIFICATIONREFERENCE($,'23-39 19 11 11','Approach Indication Equipment',#8140,$,$); +#8142=IFCCLASSIFICATIONREFERENCE($,'23-39 19 11 13','Aviation Monitoring Equipment',#8140,$,$); +#8143=IFCCLASSIFICATIONREFERENCE($,'23-39 19 11 13 11','Aviation Windsocks',#8142,$,$); +#8144=IFCCLASSIFICATIONREFERENCE($,'23-39 19 13','Aviation Barriers',#8139,$,$); +#8145=IFCCLASSIFICATIONREFERENCE($,'23-39 19 13 11','Jet Blast Barriers',#8144,$,$); +#8146=IFCCLASSIFICATIONREFERENCE($,'23-39 19 13 13','Aviation Sound Barriers',#8144,$,$); +#8147=IFCCLASSIFICATIONREFERENCE($,'23-39 21 00','Marine Construction Waterways and Seaways',#8035,$,$); +#8148=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11','Navigation Facilities',#8147,$,$); +#8149=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 11','Components',#8148,$,$); +#8150=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 11 11','Mooring Posts',#8149,$,$); +#8151=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 11 13','Boat Fenders',#8149,$,$); +#8152=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 13','Canal Locks',#8148,$,$); +#8153=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 13 11','Canal Lock Gates',#8152,$,$); +#8154=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 13 11 11','Canal Hydraulic Gates',#8153,$,$); +#8155=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 13 11 13','Canal High Pressure Gates',#8153,$,$); +#8156=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 13 11 15','Canal Hinged Leaf Gates',#8153,$,$); +#8157=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 13 11 17','Canal Radial Gates',#8153,$,$); +#8158=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 13 11 19','Canal Slide Gates',#8153,$,$); +#8159=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 13 11 21','Canal Sluice Gates',#8153,$,$); +#8160=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 13 11 23','Canal Spillway Crest Gates',#8153,$,$); +#8161=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 13 11 25','Canal Vertical Lift Gates',#8153,$,$); +#8162=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 13 13','Canal Hydraulic Valves',#8152,$,$); +#8163=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 13 13 11','Canal Butterfly Valves',#8162,$,$); +#8164=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 13 13 13','Canal Regulating Valves',#8162,$,$); +#8165=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 15','Piers and Docks',#8148,$,$); +#8166=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 15 11','Floating Docks',#8165,$,$); +#8167=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 15 13','Dock Loading Ramps',#8165,$,$); +#8168=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 17','Pontoons',#8148,$,$); +#8169=IFCCLASSIFICATIONREFERENCE($,'23-39 21 11 19','Jetties',#8148,$,$); +#8170=IFCCLASSIFICATIONREFERENCE($,'23-39 21 13','Waterflow Controls',#8147,$,$); +#8171=IFCCLASSIFICATIONREFERENCE($,'23-39 21 13 11','Reservoirs',#8170,$,$); +#8172=IFCCLASSIFICATIONREFERENCE($,'23-39 21 13 13','Dams, Dikes',#8170,$,$); +#8173=IFCCLASSIFICATIONREFERENCE($,'23-39 21 13 15','Weirs',#8170,$,$); +#8174=IFCCLASSIFICATIONREFERENCE($,'23-39 21 13 17','Barrages',#8170,$,$); +#8175=IFCCLASSIFICATIONREFERENCE($,'23-39 21 13 19','Bifurcation Panels',#8170,$,$); +#8176=IFCCLASSIFICATIONREFERENCE($,'23-39 21 13 21','Manifolds',#8170,$,$); +#8177=IFCCLASSIFICATIONREFERENCE($,'23-39 21 13 23','Penstocks and Sluice Gate',#8170,$,$); +#8178=IFCCLASSIFICATIONREFERENCE($,'23-39 21 13 25','Trash Rakes',#8170,$,$); +#8179=IFCCLASSIFICATIONREFERENCE($,'23-39 21 15','Breakwater Products',#8147,$,$); +#8180=IFCCLASSIFICATIONREFERENCE($,'23-39 21 15 11','Bulkheads',#8179,$,$); +#8181=IFCCLASSIFICATIONREFERENCE($,'23-39 21 15 13','Seawalls',#8179,$,$); +#8182=IFCCLASSIFICATIONREFERENCE($,'23-39 21 15 15','Moles and Breakwater',#8179,$,$); +#8183=IFCCLASSIFICATIONREFERENCE($,'23-39 21 15 17','Groins',#8179,$,$); +#8184=IFCCLASSIFICATIONREFERENCE($,'23-39 21 17','Marine Monitoring and Control',#8147,$,$); +#8185=IFCCLASSIFICATIONREFERENCE($,'23-39 21 17 11','Navigation Signs',#8184,$,$); +#8186=IFCCLASSIFICATIONREFERENCE($,'23-39 21 17 13','Navigation Lights',#8184,$,$); +#8187=IFCCLASSIFICATIONREFERENCE($,'23-39 21 17 15','Navigation Monitoring Equipment',#8184,$,$); +#8188=IFCCLASSIFICATIONREFERENCE($,'23-39 23 00','Electrical Utility Equipment',#8035,$,$); +#8189=IFCCLASSIFICATIONREFERENCE($,'23-39 23 11','Electrical Transmission Equipment',#8188,$,$); +#8190=IFCCLASSIFICATIONREFERENCE($,'23-39 23 11 11','Electrical Utility Poles',#8189,$,$); +#8191=IFCCLASSIFICATIONREFERENCE($,'23-39 23 11 13','Electrical Utility Towers',#8189,$,$); +#8192=IFCCLASSIFICATIONREFERENCE($,'23-39 25 00','Natural Gas Utility Equipment',#8035,$,$); +#8193=IFCCLASSIFICATIONREFERENCE($,'23-39 25 11','Natural Gas Utility Pipeline Equipment',#8192,$,$); +#8194=IFCCLASSIFICATIONREFERENCE($,'23-39 27 00','Water Utility Equipment',#8035,$,$); +#8195=IFCCLASSIFICATIONREFERENCE($,'23-39 27 11','Water Utility Pipeline Equipment',#8194,$,$); +#8196=IFCCLASSIFICATIONREFERENCE($,'23-39 29 00','Waste Water Collection and Removal',#8035,$,$); +#8197=IFCCLASSIFICATIONREFERENCE($,'23-39 29 11','Waste Water Drains',#8196,$,$); +#8198=IFCCLASSIFICATIONREFERENCE($,'23-39 29 11 11','Waste Water French Drains',#8197,$,$); +#8199=IFCCLASSIFICATIONREFERENCE($,'23-39 29 11 13','Waste Water Storm Drain',#8197,$,$); +#8200=IFCCLASSIFICATIONREFERENCE($,'23-39 29 11 13 11','Manhole (Goes in Prefab Concrete)',#8199,$,$); +#8201=IFCCLASSIFICATIONREFERENCE($,'23-39 29 11 13 13','Manhole Cover',#8199,$,$); +#8202=IFCCLASSIFICATIONREFERENCE($,'23-39 29 11 13 15','Manhole Ladder',#8199,$,$); +#8203=IFCCLASSIFICATIONREFERENCE($,'23-39 29 11 13 17','Manhole Rung',#8199,$,$); +#8204=IFCCLASSIFICATIONREFERENCE($,'23-39 29 11 15','Waste Water Drainage Pipes, Couplings, Collectors',#8197,$,$); +#8205=IFCCLASSIFICATIONREFERENCE($,'23-39 29 11 17','Wastewater Pipework Access Fittings',#8197,$,$); +#8206=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13','Waste Water Subdrainage',#8196,$,$); +#8207=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13 11','Geocomposite Drains',#8206,$,$); +#8208=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13 13','Geotextile Subsurface Drainage Filtration',#8206,$,$); +#8209=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13 15','Pipe Underdrain and Pavement Base Drain',#8206,$,$); +#8210=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13 17','Subgrade Drains',#8206,$,$); +#8211=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13 19','Surface Water Drainage Systems',#8206,$,$); +#8212=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13 19 11','Surface Water Catch Basins, Grates, and Frames',#8211,$,$); +#8213=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13 19 13','Combination Storm Drain and Underdrain Inlets',#8211,$,$); +#8214=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13 19 15','Storm Drainage Manholes, Frames, and Covers',#8211,$,$); +#8215=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13 19 17','Surface Water Retention Chambers',#8211,$,$); +#8216=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13 21','Storm Water Ponds and Reservoirs',#8206,$,$); +#8217=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13 21 19','Surface Water Retention Basins',#8216,$,$); +#8218=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13 21 21','Storm Water Pond Covers',#8216,$,$); +#8219=IFCCLASSIFICATIONREFERENCE($,'23-39 29 13 21 23','Storm Water Pond Liners',#8216,$,$); +#8220=IFCCLASSIFICATIONREFERENCE($,'23-39 29 15','Waste Water Channels, Gullies, Gratings, Covers',#8196,$,$); +#8221=IFCCLASSIFICATIONREFERENCE($,'23-39 31 00','Packaged Waste Water Treatment',#8035,$,$); +#8222=IFCCLASSIFICATIONREFERENCE($,'23-39 31 11','Packaged Stations',#8221,$,$); +#8223=IFCCLASSIFICATIONREFERENCE($,'23-39 31 11 11','Packaged Pumping Stations',#8222,$,$); +#8224=IFCCLASSIFICATIONREFERENCE($,'23-39 31 11 13','Packaged Lift Stations',#8222,$,$); +#8225=IFCCLASSIFICATIONREFERENCE($,'23-39 31 13','Packaged Sewage Treatment Plants',#8221,$,$); +#8226=IFCCLASSIFICATIONREFERENCE($,'23-39 33 00','Water and Waste Water Preliminary Treatment Equipment',#8035,$,$); +#8227=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11','Screening Equipment',#8226,$,$); +#8228=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 11','Climber-type Bar Screens',#8227,$,$); +#8229=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 13','Chain-and-Rage Bar Screens',#8227,$,$); +#8230=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 15','Flexible Rake Bar Screens',#8227,$,$); +#8231=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 17','Catenary Bar Screens',#8227,$,$); +#8232=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 19','Continuous Belt Screens',#8227,$,$); +#8233=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 21','Cylindrical Bar Screens',#8227,$,$); +#8234=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 23','Step Screens',#8227,$,$); +#8235=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 25','Rotary Drum Screens',#8227,$,$); +#8236=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 27','Spiral Screens',#8227,$,$); +#8237=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 29','Band Screens',#8227,$,$); +#8238=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 31','Disc Screens',#8227,$,$); +#8239=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 33','Traveling Screens',#8227,$,$); +#8240=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 35','Perforated Plate Screens',#8227,$,$); +#8241=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 37','Wedge Wire Screens',#8227,$,$); +#8242=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 39','Element Screens',#8227,$,$); +#8243=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 41','Trash Raking Equipment',#8227,$,$); +#8244=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 43','Screenings Washing and Compacting Equipment',#8227,$,$); +#8245=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 45','Vacuum Screenings Conveying Equipment',#8227,$,$); +#8246=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 47','Screenings Storage Containers',#8227,$,$); +#8247=IFCCLASSIFICATIONREFERENCE($,'23-39 33 11 49','Septage Receiving Equipment',#8227,$,$); +#8248=IFCCLASSIFICATIONREFERENCE($,'23-39 33 13','Grit Removal and Handling Equipment',#8226,$,$); +#8249=IFCCLASSIFICATIONREFERENCE($,'23-39 33 13 11','Chain-and-Bucket Grit Removal Equipment',#8248,$,$); +#8250=IFCCLASSIFICATIONREFERENCE($,'23-39 33 13 13','Chain-and-Flight Grit Removal Equipment',#8248,$,$); +#8251=IFCCLASSIFICATIONREFERENCE($,'23-39 33 13 15','Vortex Grit Removal Equipment',#8248,$,$); +#8252=IFCCLASSIFICATIONREFERENCE($,'23-39 33 13 17','Cyclone Degritters',#8248,$,$); +#8253=IFCCLASSIFICATIONREFERENCE($,'23-39 33 13 19','Aerated Grit Removal Equipment',#8248,$,$); +#8254=IFCCLASSIFICATIONREFERENCE($,'23-39 33 13 21','Inline Baffled Grit Removal Equipment',#8248,$,$); +#8255=IFCCLASSIFICATIONREFERENCE($,'23-39 33 13 23','Traveling Bridge Grit Removal Equipment',#8248,$,$); +#8256=IFCCLASSIFICATIONREFERENCE($,'23-39 33 13 25','Grit Classifying and Washing Equipment',#8248,$,$); +#8257=IFCCLASSIFICATIONREFERENCE($,'23-39 33 13 27','Grit Storage Containers',#8248,$,$); +#8258=IFCCLASSIFICATIONREFERENCE($,'23-39 33 15','Grinding and Shredding Equipment',#8226,$,$); +#8259=IFCCLASSIFICATIONREFERENCE($,'23-39 33 15 11','Macerators',#8258,$,$); +#8260=IFCCLASSIFICATIONREFERENCE($,'23-39 33 15 13','Comminutors',#8258,$,$); +#8261=IFCCLASSIFICATIONREFERENCE($,'23-39 33 15 15','Inline Grinders',#8258,$,$); +#8262=IFCCLASSIFICATIONREFERENCE($,'23-39 33 15 17','Open-Channel Grinders',#8258,$,$); +#8263=IFCCLASSIFICATIONREFERENCE($,'23-39 33 15 19','Modular Grinding-Screening-Compacting Equipment',#8258,$,$); +#8264=IFCCLASSIFICATIONREFERENCE($,'23-39 33 17','Oil and Grease Separation and Removal Equipment',#8226,$,$); +#8265=IFCCLASSIFICATIONREFERENCE($,'23-39 33 17 11','Coalescing Oil-Water Separators',#8264,$,$); +#8266=IFCCLASSIFICATIONREFERENCE($,'23-39 33 17 13','API Oil-Water Separators',#8264,$,$); +#8267=IFCCLASSIFICATIONREFERENCE($,'23-39 33 17 15','Grease Traps',#8264,$,$); +#8268=IFCCLASSIFICATIONREFERENCE($,'23-39 33 17 17','Dissolved Air Flotation Grease and Oil Separation Equipment',#8264,$,$); +#8269=IFCCLASSIFICATIONREFERENCE($,'23-39 33 17 19','Helical Scum Skimming and Removal Equipment',#8264,$,$); +#8270=IFCCLASSIFICATIONREFERENCE($,'23-39 33 17 21','Tipping Trough Scum Skimming and Removal Equipment',#8264,$,$); +#8271=IFCCLASSIFICATIONREFERENCE($,'23-39 33 17 23','Chain and Flight Scum Collection and Removal Equipment',#8264,$,$); +#8272=IFCCLASSIFICATIONREFERENCE($,'23-39 33 17 25','Floating Scum Skimming and Removal Equipment',#8264,$,$); +#8273=IFCCLASSIFICATIONREFERENCE($,'23-39 35 00','Water and Wastewater Chemical Feed Equipment',#8035,$,$); +#8274=IFCCLASSIFICATIONREFERENCE($,'23-39 35 11','Gas Chemical Feed Equipment',#8273,$,$); +#8275=IFCCLASSIFICATIONREFERENCE($,'23-39 35 11 11','Chlorine Gas Feed Equipment',#8274,$,$); +#8276=IFCCLASSIFICATIONREFERENCE($,'23-39 35 11 13','Sulfur Dioxide Gas Feed Equipment',#8274,$,$); +#8277=IFCCLASSIFICATIONREFERENCE($,'23-39 35 11 15','Ammonia Gas Feed Equipment',#8274,$,$); +#8278=IFCCLASSIFICATIONREFERENCE($,'23-39 35 11 17','Gas Storage, Weighing, and Leak Detection Equipment',#8274,$,$); +#8279=IFCCLASSIFICATIONREFERENCE($,'23-39 35 11 19','Chlorine Dioxide Reactors',#8274,$,$); +#8280=IFCCLASSIFICATIONREFERENCE($,'23-39 35 11 21','Carbon Dioxide Gas Feed Equipment',#8274,$,$); +#8281=IFCCLASSIFICATIONREFERENCE($,'23-39 35 11 23','Ozone Generating and Feed Equipment',#8274,$,$); +#8282=IFCCLASSIFICATIONREFERENCE($,'23-39 35 11 25','Liquid Oxygen Storage and Feed Equipment',#8274,$,$); +#8283=IFCCLASSIFICATIONREFERENCE($,'23-39 35 11 27','Cleaning Requirements for Oxygen Service',#8274,$,$); +#8284=IFCCLASSIFICATIONREFERENCE($,'23-39 35 11 29','Gas Chemical Feed Accessories and Safety Equipment',#8274,$,$); +#8285=IFCCLASSIFICATIONREFERENCE($,'23-39 35 13','Liquid Chemical Feed Equipment',#8273,$,$); +#8286=IFCCLASSIFICATIONREFERENCE($,'23-39 35 13 11','Sodium Hypochlorite Generating Equipment',#8285,$,$); +#8287=IFCCLASSIFICATIONREFERENCE($,'23-39 35 13 13','Liquid Chemical Weighing Equipment',#8285,$,$); +#8288=IFCCLASSIFICATIONREFERENCE($,'23-39 35 13 15','Polymer Blending and Feed Equipment',#8285,$,$); +#8289=IFCCLASSIFICATIONREFERENCE($,'23-39 35 13 17','Diaphragm-type Metering Pumps',#8285,$,$); +#8290=IFCCLASSIFICATIONREFERENCE($,'23-39 35 13 19','Peristaltic Metering Pumps',#8285,$,$); +#8291=IFCCLASSIFICATIONREFERENCE($,'23-39 35 13 21','Progressing Cavity Metering Pumps',#8285,$,$); +#8292=IFCCLASSIFICATIONREFERENCE($,'23-39 35 13 23','Lobe Metering Pumps',#8285,$,$); +#8293=IFCCLASSIFICATIONREFERENCE($,'23-39 35 13 25','Drum Pumps',#8285,$,$); +#8294=IFCCLASSIFICATIONREFERENCE($,'23-39 35 13 27','Liquid Chemical Transfer Pumps',#8285,$,$); +#8295=IFCCLASSIFICATIONREFERENCE($,'23-39 35 13 29','Liquid Chemical Diffusers',#8285,$,$); +#8296=IFCCLASSIFICATIONREFERENCE($,'23-39 35 13 31','Liquid Chemical Feed Accessories and Safety Equipment',#8285,$,$); +#8297=IFCCLASSIFICATIONREFERENCE($,'23-39 35 15','Dry Chemical Feed Equipment',#8273,$,$); +#8298=IFCCLASSIFICATIONREFERENCE($,'23-39 35 15 11','Storage Silos',#8297,$,$); +#8299=IFCCLASSIFICATIONREFERENCE($,'23-39 35 15 13','Dry Chemical Weighing Equipment',#8297,$,$); +#8300=IFCCLASSIFICATIONREFERENCE($,'23-39 35 15 15','Volumetric Feed Equipment',#8297,$,$); +#8301=IFCCLASSIFICATIONREFERENCE($,'23-39 35 15 17','Gravimetric Feed Equipment',#8297,$,$); +#8302=IFCCLASSIFICATIONREFERENCE($,'23-39 35 15 19','Lime Slaking Equipment',#8297,$,$); +#8303=IFCCLASSIFICATIONREFERENCE($,'23-39 35 15 21','Chemical Tablet Feeding Equipment',#8297,$,$); +#8304=IFCCLASSIFICATIONREFERENCE($,'23-39 35 15 23','Dry Chemical Feed Accessories and Safety Equipment',#8297,$,$); +#8305=IFCCLASSIFICATIONREFERENCE($,'23-39 37 00','Water and Wastewater Clarification and Mixing Equipment',#8035,$,$); +#8306=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11','Mixing Equipment',#8305,$,$); +#8307=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 11','Rapid Mixers',#8306,$,$); +#8308=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 13','Inline Blender-type Rapid Mixers',#8306,$,$); +#8309=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 15','Induction-type Rapid Mixing Equipment',#8306,$,$); +#8310=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 17','Inline Static Mixers',#8306,$,$); +#8311=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 19','Mixing Equipment',#8306,$,$); +#8312=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 21','Submersible Mixers',#8306,$,$); +#8313=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 23','Floating Mechanical Mixers',#8306,$,$); +#8314=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 25','Paddle Mixers',#8306,$,$); +#8315=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 27','Pin Mixers',#8306,$,$); +#8316=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 29','Vertical Reel Flocculation Equipment',#8306,$,$); +#8317=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 31','Horizontal Reel Flocculation Equipment',#8306,$,$); +#8318=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 33','Vertical Turbine Flocculation Equipment',#8306,$,$); +#8319=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 35','Walking-beam Flocculation Equipment',#8306,$,$); +#8320=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 37','Horizontal Oscillating Flocculation Equipment',#8306,$,$); +#8321=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 39','Top-entering Tank Mixers',#8306,$,$); +#8322=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 41','Side-entry Tank Mixers',#8306,$,$); +#8323=IFCCLASSIFICATIONREFERENCE($,'23-39 37 11 43','Portable Tank Mixers',#8306,$,$); +#8324=IFCCLASSIFICATIONREFERENCE($,'23-39 37 13','Clarifier Equipment',#8305,$,$); +#8325=IFCCLASSIFICATIONREFERENCE($,'23-39 37 13 11','Chain-and-Flight Clarifier Equipment',#8324,$,$); +#8326=IFCCLASSIFICATIONREFERENCE($,'23-39 37 13 13','Traveling Bridge Clarifier Equipment',#8324,$,$); +#8327=IFCCLASSIFICATIONREFERENCE($,'23-39 37 13 15','Differential Head Clarifier Equipment',#8324,$,$); +#8328=IFCCLASSIFICATIONREFERENCE($,'23-39 37 13 17','Oscillating Scraper-type Clarifier Equipment',#8324,$,$); +#8329=IFCCLASSIFICATIONREFERENCE($,'23-39 37 13 19','Circular Clarifier Equipment',#8324,$,$); +#8330=IFCCLASSIFICATIONREFERENCE($,'23-39 37 13 21','Solids Contact Clarifier Equipment',#8324,$,$); +#8331=IFCCLASSIFICATIONREFERENCE($,'23-39 37 13 23','Flocculating Clarifier, Pulsating Sludge Blanket Type',#8324,$,$); +#8332=IFCCLASSIFICATIONREFERENCE($,'23-39 37 13 25','Dissolved Air Flotation Equipment for Water Treatment',#8324,$,$); +#8333=IFCCLASSIFICATIONREFERENCE($,'23-39 37 13 27','Ballasted High-rate Clarifier Equipment',#8324,$,$); +#8334=IFCCLASSIFICATIONREFERENCE($,'23-39 37 13 29','High rate Clarification/Thickening Equipment',#8324,$,$); +#8335=IFCCLASSIFICATIONREFERENCE($,'23-39 37 13 31','Tube Settlers',#8324,$,$); +#8336=IFCCLASSIFICATIONREFERENCE($,'23-39 37 13 33','Lined Plate Settlers',#8324,$,$); +#8337=IFCCLASSIFICATIONREFERENCE($,'23-39 37 15','Sediment Removal Equipment',#8305,$,$); +#8338=IFCCLASSIFICATIONREFERENCE($,'23-39 37 15 11','Tipping Sediment Flushing Tanks',#8337,$,$); +#8339=IFCCLASSIFICATIONREFERENCE($,'23-39 37 15 13','Flushing Gates',#8337,$,$); +#8340=IFCCLASSIFICATIONREFERENCE($,'23-39 37 15 15','Water Cannon',#8337,$,$); +#8341=IFCCLASSIFICATIONREFERENCE($,'23-39 39 00','Water and Wastewater Secondary Treatment Equipment',#8035,$,$); +#8342=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11','Air and Gas Diffusion Equipment',#8341,$,$); +#8343=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 11','Fixed Mechanical Aerators',#8342,$,$); +#8344=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 13','Floating Mechanical Aerators',#8342,$,$); +#8345=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 15','Submersible Aspirating Aerator Equipment',#8342,$,$); +#8346=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 17','Jet Aeration Equipment',#8342,$,$); +#8347=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 19','Coarse Bubble Diffusers',#8342,$,$); +#8348=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 21','Swing-type Channel Aeration Equipment',#8342,$,$); +#8349=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 23','Shear Box Diffusers',#8342,$,$); +#8350=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 25','Flexible Membrane Tube Diffusers',#8342,$,$); +#8351=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 27','Flexible Membrane Disc Diffusers',#8342,$,$); +#8352=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 29','Ceramic Disc Fine Bubble Diffusers',#8342,$,$); +#8353=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 31','Floating Membrane Diffusers',#8342,$,$); +#8354=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 33','Membrane Diffusers',#8342,$,$); +#8355=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 35','Cascading Aerators',#8342,$,$); +#8356=IFCCLASSIFICATIONREFERENCE($,'23-39 39 11 37','Pure-oxygen Generating Equipment',#8342,$,$); +#8357=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13','Biological Treatment Systems',#8341,$,$); +#8358=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13 11','Rotating Biological Contactors',#8357,$,$); +#8359=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13 13','Trickling Filter Rotary Distributor Equipment',#8357,$,$); +#8360=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13 15','Trickling Filter Media',#8357,$,$); +#8361=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13 17','Bio-towers',#8357,$,$); +#8362=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13 19','Moving-bed Biological Reactors',#8357,$,$); +#8363=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13 21','Integrated Fixed-film Activated Sludge Equipment',#8357,$,$); +#8364=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13 23','Intermittent Sand Filters for Wastewater Treatment',#8357,$,$); +#8365=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13 25','Deep-bed Denitrification Filters',#8357,$,$); +#8366=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13 27','Biologically Activated Filters',#8357,$,$); +#8367=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13 29','Membrane Biological Reactors',#8357,$,$); +#8368=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13 31','Sequencing Batch Reactors',#8357,$,$); +#8369=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13 33','Oxidation Ditch Equipment',#8357,$,$); +#8370=IFCCLASSIFICATIONREFERENCE($,'23-39 39 13 35','Vertical Loop Reactors',#8357,$,$); +#8371=IFCCLASSIFICATIONREFERENCE($,'23-39 41 00','Water and Wastewater Advanced Treatment Equipment',#8035,$,$); +#8372=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11','Filtration Equipment',#8371,$,$); +#8373=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 11','Filter Media',#8372,$,$); +#8374=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 13','Filter Surface Wash Agitators',#8372,$,$); +#8375=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 15','Filter Air Scour Equipment',#8372,$,$); +#8376=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 17','Wash Water Troughs',#8372,$,$); +#8377=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 19','Pressure Filters',#8372,$,$); +#8378=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 21','Gravity Filters',#8372,$,$); +#8379=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 23','High-rate Sand Filters',#8372,$,$); +#8380=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 25','Traveling Bridge Filters',#8372,$,$); +#8381=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 27','Microfiltration and Ultrafiltration Membrane Equipment',#8372,$,$); +#8382=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 29','Disc Cloth Filters',#8372,$,$); +#8383=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 31','Rotary Drum Cloth Filters',#8372,$,$); +#8384=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 33','Automatic Backwash Cloth Filter Equipment',#8372,$,$); +#8385=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 35','Cartridge Filters',#8372,$,$); +#8386=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 37','Bag Filters',#8372,$,$); +#8387=IFCCLASSIFICATIONREFERENCE($,'23-39 41 11 39','Automatic Straining Equipment',#8372,$,$); +#8388=IFCCLASSIFICATIONREFERENCE($,'23-39 41 13','Demineralization Equipment',#8371,$,$); +#8389=IFCCLASSIFICATIONREFERENCE($,'23-39 41 13 11','Ion-exchange Vessel Media',#8388,$,$); +#8390=IFCCLASSIFICATIONREFERENCE($,'23-39 41 13 13','Electrodialysis Reversal Equipment',#8388,$,$); +#8391=IFCCLASSIFICATIONREFERENCE($,'23-39 41 13 15','Reverse Osmosis and Nanofiltration Membrane Equipment',#8388,$,$); +#8392=IFCCLASSIFICATIONREFERENCE($,'23-39 41 13 17','Multiple-effect Distillation Equipment',#8388,$,$); +#8393=IFCCLASSIFICATIONREFERENCE($,'23-39 41 13 19','Desalination Mechanical Vapor Compression Equipment',#8388,$,$); +#8394=IFCCLASSIFICATIONREFERENCE($,'23-39 41 13 21','Desalination Thermal Vapor Compression Equipment',#8388,$,$); +#8395=IFCCLASSIFICATIONREFERENCE($,'23-39 41 13 23','Desalination Multi-stage Flash Equipment',#8388,$,$); +#8396=IFCCLASSIFICATIONREFERENCE($,'23-39 41 13 25','Desalination Falling Film Evaporators',#8388,$,$); +#8397=IFCCLASSIFICATIONREFERENCE($,'23-39 41 13 27','Desalination Rising Film Evaporators',#8388,$,$); +#8398=IFCCLASSIFICATIONREFERENCE($,'23-39 41 13 29','Desalination Forced-circulation Crystallizing Equipment',#8388,$,$); +#8399=IFCCLASSIFICATIONREFERENCE($,'23-39 41 13 31','Desalination Spray Dry Evaporation Equipment',#8388,$,$); +#8400=IFCCLASSIFICATIONREFERENCE($,'23-39 41 13 33','Demineralization Energy Recovery Equipment',#8388,$,$); +#8401=IFCCLASSIFICATIONREFERENCE($,'23-39 41 15','Ultraviolet Equipment',#8371,$,$); +#8402=IFCCLASSIFICATIONREFERENCE($,'23-39 41 15 11','Closed-vessel Low-pressure/Low-intensity Ultraviolet Treatment Equipment',#8401,$,$); +#8403=IFCCLASSIFICATIONREFERENCE($,'23-39 41 15 13','Closed-vessel Low-pressure/High-intensity Ultraviolet Treatment Equipment',#8401,$,$); +#8404=IFCCLASSIFICATIONREFERENCE($,'23-39 41 15 15','Closed-vessel Medium-pressure Ultraviolet Treatment Equipment',#8401,$,$); +#8405=IFCCLASSIFICATIONREFERENCE($,'23-39 41 15 17','Open-channel Low-pressure/Low-intensity Ultraviolet Treatment Equipment',#8401,$,$); +#8406=IFCCLASSIFICATIONREFERENCE($,'23-39 41 15 19','Open-channel Low-pressure/High-intensity Ultraviolet Treatment Equipment',#8401,$,$); +#8407=IFCCLASSIFICATIONREFERENCE($,'23-39 41 15 21','Open-channel Medium-pressure Ultraviolet Treatment Equipment',#8401,$,$); +#8408=IFCCLASSIFICATIONREFERENCE($,'23-39 43 00','Water and Wastewater Residuals Handling and Treatment',#8035,$,$); +#8409=IFCCLASSIFICATIONREFERENCE($,'23-39 43 11','Residuals Thickening Equipment',#8408,$,$); +#8410=IFCCLASSIFICATIONREFERENCE($,'23-39 43 11 11','Circular Gravity Thickeners',#8409,$,$); +#8411=IFCCLASSIFICATIONREFERENCE($,'23-39 43 11 13','Gravity Belt Thickeners',#8409,$,$); +#8412=IFCCLASSIFICATIONREFERENCE($,'23-39 43 11 15','Dissolved Air Flotation Thickening Equipment',#8409,$,$); +#8413=IFCCLASSIFICATIONREFERENCE($,'23-39 43 11 17','Rotary Drum Thickening Equipment',#8409,$,$); +#8414=IFCCLASSIFICATIONREFERENCE($,'23-39 43 11 19','Centrifuge Thickening Equipment',#8409,$,$); +#8415=IFCCLASSIFICATIONREFERENCE($,'23-39 43 11 21','Disc Thickeners',#8409,$,$); +#8416=IFCCLASSIFICATIONREFERENCE($,'23-39 43 11 23','Thickening Screw Press',#8409,$,$); +#8417=IFCCLASSIFICATIONREFERENCE($,'23-39 43 11 25','Scum Concentrator Equipment',#8409,$,$); +#8418=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13','Residuals Stabilization',#8408,$,$); +#8419=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 11','Digester Covers and Appurtenances',#8418,$,$); +#8420=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 11 11','Fixed Covers',#8419,$,$); +#8421=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 11 13','Floating Covers',#8419,$,$); +#8422=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 11 15','Gasholder Covers',#8419,$,$); +#8423=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 13','Radial Beam Fixed Digester Covers',#8418,$,$); +#8424=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 15','Dual Deck Truss-type Fixed Digester Covers',#8418,$,$); +#8425=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 17','Radial Beam Floating Digester Covers',#8418,$,$); +#8426=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 19','Dual Deck Truss-type Floating Digester Covers',#8418,$,$); +#8427=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 21','Radial Beam Floating Gas-holding Digester Covers',#8418,$,$); +#8428=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 23','Dual Deck Truss-type Floating Gas-holding Digester Covers',#8418,$,$); +#8429=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 25','Digester Appurtenances',#8418,$,$); +#8430=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 27','Aerobic Digester Aeration Equipment',#8418,$,$); +#8431=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 29','Autothermal Thermophilic Aerobic Digestion Equipment',#8418,$,$); +#8432=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 31','Egg-shaped Digesters',#8418,$,$); +#8433=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 33','Confined Gas Mixing System',#8418,$,$); +#8434=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 35','Digester Heating Equipment',#8418,$,$); +#8435=IFCCLASSIFICATIONREFERENCE($,'23-39 43 13 37','Residuals Pasteurization Equipment',#8418,$,$); +#8436=IFCCLASSIFICATIONREFERENCE($,'23-39 43 15','Residuals Dewatering Equipment',#8408,$,$); +#8437=IFCCLASSIFICATIONREFERENCE($,'23-39 43 15 11','Vacuum Filters',#8436,$,$); +#8438=IFCCLASSIFICATIONREFERENCE($,'23-39 43 15 13','Belt Filter Presses',#8436,$,$); +#8439=IFCCLASSIFICATIONREFERENCE($,'23-39 43 15 15','Plate-and-Frame Filter Presses',#8436,$,$); +#8440=IFCCLASSIFICATIONREFERENCE($,'23-39 43 15 17','Rotary Presses',#8436,$,$); +#8441=IFCCLASSIFICATIONREFERENCE($,'23-39 43 15 19','Screw Presses',#8436,$,$); +#8442=IFCCLASSIFICATIONREFERENCE($,'23-39 43 15 21','Dewatering Centrifuges',#8436,$,$); +#8443=IFCCLASSIFICATIONREFERENCE($,'23-39 43 15 23','Belt Dryers',#8436,$,$); +#8444=IFCCLASSIFICATIONREFERENCE($,'23-39 43 15 25','Direct-heat Residuals Drying Equipment',#8436,$,$); +#8445=IFCCLASSIFICATIONREFERENCE($,'23-39 43 15 27','Indirect-heat Residuals Drying Equipment',#8436,$,$); +#8446=IFCCLASSIFICATIONREFERENCE($,'23-39 43 17','Thermal Treatment of Residuals',#8408,$,$); +#8447=IFCCLASSIFICATIONREFERENCE($,'23-39 43 17 11','Multiple-hearth Sludge Incinerators',#8446,$,$); +#8448=IFCCLASSIFICATIONREFERENCE($,'23-39 43 17 13','Fluidized-bed Sludge Incinerators',#8446,$,$); +#8449=IFCCLASSIFICATIONREFERENCE($,'23-39 43 17 15','Ash Handling Equipment',#8446,$,$); +#8450=IFCCLASSIFICATIONREFERENCE($,'23-39 43 17 17','Recuperative Air Preheating Equipment',#8446,$,$); +#8451=IFCCLASSIFICATIONREFERENCE($,'23-39 43 17 19','Regenerative Thermal Oxidizers',#8446,$,$); +#8452=IFCCLASSIFICATIONREFERENCE($,'23-39 43 17 21','Waste Heat Recovery Boilers',#8446,$,$); +#8453=IFCCLASSIFICATIONREFERENCE($,'23-39 43 17 23','Waste Heat Recovery Heat Exchangers',#8446,$,$); +#8454=IFCCLASSIFICATIONREFERENCE($,'23-39 43 17 25','Thermal Oxidation Equipment',#8446,$,$); +#8455=IFCCLASSIFICATIONREFERENCE($,'23-39 45 00','Septic System Equipment',#8035,$,$); +#8456=IFCCLASSIFICATIONREFERENCE($,'23-39 45 11','Liquid Waste Treatment',#8455,$,$); +#8457=IFCCLASSIFICATIONREFERENCE($,'23-39 45 11 11','Liquid Waste Decanter',#8456,$,$); +#8458=IFCCLASSIFICATIONREFERENCE($,'23-39 45 11 13','Bacterial Filter Tanks',#8456,$,$); +#8459=IFCCLASSIFICATIONREFERENCE($,'23-39 45 11 15','Liquid Waste Decanters',#8456,$,$); +#8460=IFCCLASSIFICATIONREFERENCE($,'23-39 45 11 17','Liquid Waste Separators',#8456,$,$); +#8461=IFCCLASSIFICATIONREFERENCE($,'23-39 45 11 19','Liquid Waste Pond and Reservoir Products',#8456,$,$); +#8462=IFCCLASSIFICATIONREFERENCE($,'23-39 45 11 19 11','Liquid Waste Pond Covers',#8461,$,$); +#8463=IFCCLASSIFICATIONREFERENCE($,'23-39 45 11 19 13','Liquid Waste Pond Liners',#8461,$,$); +#8464=IFCCLASSIFICATIONREFERENCE($,'23-39 45 11 21','Additives for Treatment of Liquid Waste',#8456,$,$); +#8465=IFCCLASSIFICATIONREFERENCE($,'23-39 45 11 21 11','Additives for Waste Water and Sewage Treatment',#8464,$,$); +#8466=IFCCLASSIFICATIONREFERENCE($,'23-39 45 11 21 13','Additives for Residue Treatment',#8464,$,$); +#8467=IFCCLASSIFICATIONREFERENCE($,'23-39 45 13','Liquid Waste Monitoring and Control',#8455,$,$); +#8468=IFCCLASSIFICATIONREFERENCE($,'23-39 45 13 11','Detectors of Water Pollution',#8467,$,$); +#8469=IFCCLASSIFICATIONREFERENCE($,'23-39 45 15','Solid Waste Disposal Plant Products',#8455,$,$); +#8470=IFCCLASSIFICATIONREFERENCE($,'23-39 45 15 11','Chutes and Collectors',#8469,$,$); +#8471=IFCCLASSIFICATIONREFERENCE($,'23-39 45 15 13','Pneumatic Waste Equipment',#8469,$,$); +#8472=IFCCLASSIFICATIONREFERENCE($,'23-39 45 15 15','Incineration Plant',#8469,$,$); +#8473=IFCCLASSIFICATIONREFERENCE($,'23-39 45 15 15 11','Packaged Incinerators',#8472,$,$); +#8474=IFCCLASSIFICATIONREFERENCE($,'23-39 45 15 17','Crusher Plant',#8469,$,$); +#8475=IFCCLASSIFICATIONREFERENCE($,'23-39 45 15 17 11','Waste Compactors and Destructors',#8474,$,$); +#8476=IFCCLASSIFICATIONREFERENCE($,'23-39 45 15 19','Baling Plant',#8469,$,$); +#8477=IFCCLASSIFICATIONREFERENCE($,'23-39 45 15 21','Pulping Machines',#8469,$,$); +#8478=IFCCLASSIFICATIONREFERENCE($,'23-39 45 17','Solid Waste Handling Products',#8455,$,$); +#8479=IFCCLASSIFICATIONREFERENCE($,'23-39 45 19','Solid Waste Impelling Equipment',#8455,$,$); +#8480=IFCCLASSIFICATIONREFERENCE($,'23-39 45 21','Solid Waste Treatment Equipment',#8455,$,$); +#8481=IFCCLASSIFICATIONREFERENCE($,'23-39 45 21 11','Solid Waste Compactors, Destructors, and Balers',#8480,$,$); +#8482=IFCCLASSIFICATIONREFERENCE($,'23-39 45 21 13','Solid Waste Crushers',#8480,$,$); +#8483=IFCCLASSIFICATIONREFERENCE($,'23-39 45 21 15','Solid Waste Pulping Machines',#8480,$,$); +#8484=IFCCLASSIFICATIONREFERENCE($,'23-39 45 21 17','Solid Waste Shredding Machines',#8480,$,$); +#8485=IFCCLASSIFICATIONREFERENCE($,'23-39 45 21 19','Incinerators',#8480,$,$); +#8486=IFCCLASSIFICATIONREFERENCE($,'23-39 45 21 19 11','Solid Waste Incinerators',#8485,$,$); +#8487=IFCCLASSIFICATIONREFERENCE($,'23-39 45 21 19 13','Packaged Incinerators',#8485,$,$); +#8488=IFCCLASSIFICATIONREFERENCE($,'23-39 45 23','Solid Waste Monitoring and Control Equipment',#8455,$,$); +#8489=IFCCLASSIFICATIONREFERENCE($,'23-39 45 23 11','Solid Waste Metal Detectors',#8488,$,$); +#8490=IFCCLASSIFICATIONREFERENCE($,'23-39 45 23 13','Solid Waste Detectors for Other Solids',#8488,$,$); +#8491=IFCCLASSIFICATIONREFERENCE($,'23-39 45 25','Solid Waste Collection and Removal Products',#8455,$,$); +#8492=IFCCLASSIFICATIONREFERENCE($,'23-39 45 25 11','Complete Solid Waste Removal Systems',#8491,$,$); +#8493=IFCCLASSIFICATIONREFERENCE($,'23-39 45 25 13','Solid Waste Bins',#8491,$,$); +#8494=IFCCLASSIFICATIONREFERENCE($,'23-39 45 25 15','Gravity Chute Solid Waste Systems',#8491,$,$); +#8495=IFCCLASSIFICATIONREFERENCE($,'23-39 45 25 17','Refuse Disposal Chutes',#8491,$,$); +#8496=IFCCLASSIFICATIONREFERENCE($,'23-39 45 25 17 11','Refuse Hoppers',#8495,$,$); +#8497=IFCCLASSIFICATIONREFERENCE($,'23-39 45 25 17 13','Refuse Chute Doors',#8495,$,$); +#8498=IFCCLASSIFICATIONREFERENCE($,'23-39 45 25 17 15','Refuse Chute Decontamination Units',#8495,$,$); +#8499=IFCCLASSIFICATIONREFERENCE($,'23-39 45 27','Solid Waste Handling Systems',#8455,$,$); +#8500=IFCCLASSIFICATIONREFERENCE($,'23-39 45 27 11','Refuse Compactors',#8499,$,$); +#8501=IFCCLASSIFICATIONREFERENCE($,'23-39 45 27 13','Refuse Containers',#8499,$,$); +#8502=IFCCLASSIFICATIONREFERENCE($,'23-39 45 27 15','Dust Collectors',#8499,$,$); +#8503=IFCCLASSIFICATIONREFERENCE($,'23-39 45 27 17','Utility Poles',#8499,$,$); +#8504=IFCCLASSIFICATIONREFERENCE($,'23-39 47 00','Offshore Structures',#8035,$,$); ENDSEC; END-ISO-10303-21; diff --git a/src/ifcblenderexport/blenderbim/bim/schema/classifications/Uniclass2015_Jan2020.ifc b/src/ifcblenderexport/blenderbim/bim/schema/classifications/Uniclass2015_Jan2020.ifc index d86ffdf429..28df483776 100644 --- a/src/ifcblenderexport/blenderbim/bim/schema/classifications/Uniclass2015_Jan2020.ifc +++ b/src/ifcblenderexport/blenderbim/bim/schema/classifications/Uniclass2015_Jan2020.ifc @@ -1,12474 +1,12476 @@ ISO-10303-21; HEADER; FILE_DESCRIPTION(('ViewDefinition [CoordinationView]'),'2;1'); -FILE_NAME('','2020-04-23T11:00:34',(),(),'IfcOpenShell 0.6.0b0','IfcOpenShell 0.6.0b0',''); +FILE_NAME('','2020-04-23T18:09:38',(),(),'IfcOpenShell 0.6.0b0','IfcOpenShell 0.6.0b0',''); FILE_SCHEMA(('IFC4')); ENDSEC; DATA; -#1=IFCCLASSIFICATION('RIBA Enterprises Ltd','January 2020','2020-02-07','Uniclass 2015','Uniclass 2015 is a unified classification for the UK industry covering all construction sectors.','https://toolkit.thenbs.com/articles/classification',('_')); -#2=IFCCLASSIFICATIONREFERENCE($,'Co','Complexes',#1,$,$); -#3=IFCCLASSIFICATIONREFERENCE($,'Co_20','Administrative, commercial and protective service complexes',#2,$,$); -#4=IFCCLASSIFICATIONREFERENCE($,'Co_20_10','Legislative complexes',#3,$,$); -#5=IFCCLASSIFICATIONREFERENCE($,'Co_20_10_60','Governmental complexes',#4,$,$); -#6=IFCCLASSIFICATIONREFERENCE($,'Co_20_15','Administrative complexes',#3,$,$); -#7=IFCCLASSIFICATIONREFERENCE($,'Co_20_15_08','Business parks',#6,$,$); -#8=IFCCLASSIFICATIONREFERENCE($,'Co_20_15_58','Office complexes',#6,$,$); -#9=IFCCLASSIFICATIONREFERENCE($,'Co_20_20','Secular representative complexes',#3,$,$); -#10=IFCCLASSIFICATIONREFERENCE($,'Co_20_20_15','Complexes for representatives of nation states abroad',#9,$,$); -#11=IFCCLASSIFICATIONREFERENCE($,'Co_20_20_40','Local government complexes',#9,$,$); -#12=IFCCLASSIFICATIONREFERENCE($,'Co_20_20_50','National government complexes',#9,$,$); -#13=IFCCLASSIFICATIONREFERENCE($,'Co_20_20_70','Regional government complexes',#9,$,$); -#14=IFCCLASSIFICATIONREFERENCE($,'Co_20_45','Motor vehicle maintenance and fuelling complexes',#3,$,$); -#15=IFCCLASSIFICATIONREFERENCE($,'Co_20_45_50','Motor vehicle fuelling and charging stations',#14,$,$); -#16=IFCCLASSIFICATIONREFERENCE($,'Co_20_45_54','Motor vehicle servicing complexes',#14,$,$); -#17=IFCCLASSIFICATIONREFERENCE($,'Co_20_50','Commercial complexes',#3,$,$); -#18=IFCCLASSIFICATIONREFERENCE($,'Co_20_50_05','Auction complexes',#17,$,$); -#19=IFCCLASSIFICATIONREFERENCE($,'Co_20_50_50','Market complexes',#17,$,$); -#20=IFCCLASSIFICATIONREFERENCE($,'Co_20_50_53','Mixed use complexes',#17,$,$); -#21=IFCCLASSIFICATIONREFERENCE($,'Co_20_50_60','Parade of shops',#17,$,$); -#22=IFCCLASSIFICATIONREFERENCE($,'Co_20_50_71','Retail parks',#17,$,$); -#23=IFCCLASSIFICATIONREFERENCE($,'Co_20_50_78','Shopping complexes',#17,$,$); -#24=IFCCLASSIFICATIONREFERENCE($,'Co_20_50_94','Vehicle sales complexes',#17,$,$); -#25=IFCCLASSIFICATIONREFERENCE($,'Co_20_55','Postal complexes',#3,$,$); -#26=IFCCLASSIFICATIONREFERENCE($,'Co_20_55_10','Postal communications complexes',#25,$,$); -#27=IFCCLASSIFICATIONREFERENCE($,'Co_20_60','Military complexes',#3,$,$); -#28=IFCCLASSIFICATIONREFERENCE($,'Co_20_60_02','Air force complexes',#27,$,$); -#29=IFCCLASSIFICATIONREFERENCE($,'Co_20_60_10','Army complexes',#27,$,$); -#30=IFCCLASSIFICATIONREFERENCE($,'Co_20_60_56','Navy complexes',#27,$,$); -#31=IFCCLASSIFICATIONREFERENCE($,'Co_20_65','Law enforcement complexes',#3,$,$); -#32=IFCCLASSIFICATIONREFERENCE($,'Co_20_65_56','Law enforcement agency complexes',#31,$,$); -#33=IFCCLASSIFICATIONREFERENCE($,'Co_20_70','Judicial complexes',#3,$,$); -#34=IFCCLASSIFICATIONREFERENCE($,'Co_20_70_18','Court complexes',#33,$,$); -#35=IFCCLASSIFICATIONREFERENCE($,'Co_20_70_65','Probation complexes',#33,$,$); -#36=IFCCLASSIFICATIONREFERENCE($,'Co_20_75','Detention complexes',#3,$,$); -#37=IFCCLASSIFICATIONREFERENCE($,'Co_20_75_42','Immigrant detention complexes',#36,$,$); -#38=IFCCLASSIFICATIONREFERENCE($,'Co_20_75_64','Prison complexes',#36,$,$); -#39=IFCCLASSIFICATIONREFERENCE($,'Co_20_75_71','Refugee detention complexes',#36,$,$); -#40=IFCCLASSIFICATIONREFERENCE($,'Co_20_80','Weapons training complexes',#3,$,$); -#41=IFCCLASSIFICATIONREFERENCE($,'Co_20_80_04','Artillery firing range complexes',#40,$,$); -#42=IFCCLASSIFICATIONREFERENCE($,'Co_20_80_80','Small arms firing range complexes',#40,$,$); -#43=IFCCLASSIFICATIONREFERENCE($,'Co_20_90','Incident support complexes',#3,$,$); -#44=IFCCLASSIFICATIONREFERENCE($,'Co_20_90_02','Air and sea rescue complexes',#43,$,$); -#45=IFCCLASSIFICATIONREFERENCE($,'Co_20_90_16','Coast guard stations',#43,$,$); -#46=IFCCLASSIFICATIONREFERENCE($,'Co_20_90_27','Fire brigade complexes',#43,$,$); -#47=IFCCLASSIFICATIONREFERENCE($,'Co_20_90_47','Life boat stations',#43,$,$); -#48=IFCCLASSIFICATIONREFERENCE($,'Co_20_90_53','Mountain rescue complexes',#43,$,$); -#49=IFCCLASSIFICATIONREFERENCE($,'Co_25','Cultural, educational, scientific and information complexes',#2,$,$); -#50=IFCCLASSIFICATIONREFERENCE($,'Co_25_05','Commemorative complexes',#49,$,$); -#51=IFCCLASSIFICATIONREFERENCE($,'Co_25_10','Educational complexes',#49,$,$); -#52=IFCCLASSIFICATIONREFERENCE($,'Co_25_10_32','Further education colleges',#51,$,$); -#53=IFCCLASSIFICATIONREFERENCE($,'Co_25_10_41','Infant schools',#51,$,$); -#54=IFCCLASSIFICATIONREFERENCE($,'Co_25_10_45','Kindergartens, nurseries and pre-schools',#51,$,$); -#55=IFCCLASSIFICATIONREFERENCE($,'Co_25_10_66','Primary schools',#51,$,$); -#56=IFCCLASSIFICATIONREFERENCE($,'Co_25_10_77','Secondary schools',#51,$,$); -#57=IFCCLASSIFICATIONREFERENCE($,'Co_25_10_88','Tertiary colleges',#51,$,$); -#58=IFCCLASSIFICATIONREFERENCE($,'Co_25_10_92','Universities',#51,$,$); -#59=IFCCLASSIFICATIONREFERENCE($,'Co_25_30','Scientific complexes',#49,$,$); -#60=IFCCLASSIFICATIONREFERENCE($,'Co_25_30_04','Astronomical observatory complexes',#59,$,$); -#61=IFCCLASSIFICATIONREFERENCE($,'Co_25_30_08','Botanic gardens',#59,$,$); -#62=IFCCLASSIFICATIONREFERENCE($,'Co_25_30_45','Laboratory complexes',#59,$,$); -#63=IFCCLASSIFICATIONREFERENCE($,'Co_25_30_70','Research complexes',#59,$,$); -#64=IFCCLASSIFICATIONREFERENCE($,'Co_25_50','Exhibition complexes',#49,$,$); -#65=IFCCLASSIFICATIONREFERENCE($,'Co_25_50_03','Art installations',#64,$,$); -#66=IFCCLASSIFICATIONREFERENCE($,'Co_25_50_33','Galleries',#64,$,$); -#67=IFCCLASSIFICATIONREFERENCE($,'Co_25_50_34','Gardens and arboretums',#64,$,$); -#68=IFCCLASSIFICATIONREFERENCE($,'Co_25_50_50','Memorial complexes',#64,$,$); -#69=IFCCLASSIFICATIONREFERENCE($,'Co_25_50_52','Monument complexes',#64,$,$); -#70=IFCCLASSIFICATIONREFERENCE($,'Co_25_50_54','Multi-purpose exhibition complexes',#64,$,$); -#71=IFCCLASSIFICATIONREFERENCE($,'Co_25_50_55','Museums',#64,$,$); -#72=IFCCLASSIFICATIONREFERENCE($,'Co_25_50_58','Open air museums',#64,$,$); -#73=IFCCLASSIFICATIONREFERENCE($,'Co_25_50_59','Open air sculpture parks',#64,$,$); -#74=IFCCLASSIFICATIONREFERENCE($,'Co_25_50_99','Zoos',#64,$,$); -#75=IFCCLASSIFICATIONREFERENCE($,'Co_25_70','Information complexes',#49,$,$); -#76=IFCCLASSIFICATIONREFERENCE($,'Co_25_70_16','Conference complexes',#75,$,$); -#77=IFCCLASSIFICATIONREFERENCE($,'Co_25_70_23','Document archives',#75,$,$); -#78=IFCCLASSIFICATIONREFERENCE($,'Co_25_70_30','Film archives',#75,$,$); -#79=IFCCLASSIFICATIONREFERENCE($,'Co_25_70_41','Information centres',#75,$,$); -#80=IFCCLASSIFICATIONREFERENCE($,'Co_25_70_47','Library complexes',#75,$,$); -#81=IFCCLASSIFICATIONREFERENCE($,'Co_25_90','Worship complexes',#49,$,$); -#82=IFCCLASSIFICATIONREFERENCE($,'Co_25_90_30','Faith worship complexes',#81,$,$); -#83=IFCCLASSIFICATIONREFERENCE($,'Co_30','Industrial complexes',#2,$,$); -#84=IFCCLASSIFICATIONREFERENCE($,'Co_30_10','Mineral extraction complexes',#83,$,$); -#85=IFCCLASSIFICATIONREFERENCE($,'Co_30_10_22','Deep mines',#84,$,$); -#86=IFCCLASSIFICATIONREFERENCE($,'Co_30_10_24','Drift mines',#84,$,$); -#87=IFCCLASSIFICATIONREFERENCE($,'Co_30_10_51','Methane hydrates extraction complexes',#84,$,$); -#88=IFCCLASSIFICATIONREFERENCE($,'Co_30_10_61','Open-cast mines',#84,$,$); -#89=IFCCLASSIFICATIONREFERENCE($,'Co_30_10_69','Quarries',#84,$,$); -#90=IFCCLASSIFICATIONREFERENCE($,'Co_30_10_77','Shale gas extraction complexes',#84,$,$); -#91=IFCCLASSIFICATIONREFERENCE($,'Co_30_10_78','Shale oil extraction complexes',#84,$,$); -#92=IFCCLASSIFICATIONREFERENCE($,'Co_30_20','Nuclear and chemical management complexes',#83,$,$); -#93=IFCCLASSIFICATIONREFERENCE($,'Co_30_20_80','Surface radioactive waste management complexes',#92,$,$); -#94=IFCCLASSIFICATIONREFERENCE($,'Co_30_20_95','Underground radioactive waste management complexes',#92,$,$); -#95=IFCCLASSIFICATIONREFERENCE($,'Co_30_30','Mineral processing complexes',#83,$,$); -#96=IFCCLASSIFICATIONREFERENCE($,'Co_30_30_30','Gas processing complexes',#95,$,$); -#97=IFCCLASSIFICATIONREFERENCE($,'Co_30_30_50','Oil processing complexes',#95,$,$); -#98=IFCCLASSIFICATIONREFERENCE($,'Co_30_30_55','Ore processing complexes',#95,$,$); -#99=IFCCLASSIFICATIONREFERENCE($,'Co_30_40','Animal and plant products processing complexes',#83,$,$); -#100=IFCCLASSIFICATIONREFERENCE($,'Co_30_40_01','Abattoirs',#99,$,$); -#101=IFCCLASSIFICATIONREFERENCE($,'Co_30_40_03','Animal product processing complexes',#99,$,$); -#102=IFCCLASSIFICATIONREFERENCE($,'Co_30_40_04','Arable crop processing complexes',#99,$,$); -#103=IFCCLASSIFICATIONREFERENCE($,'Co_30_40_06','Bakeries',#99,$,$); -#104=IFCCLASSIFICATIONREFERENCE($,'Co_30_40_08','Breweries',#99,$,$); -#105=IFCCLASSIFICATIONREFERENCE($,'Co_30_40_11','Canneries',#99,$,$); -#106=IFCCLASSIFICATIONREFERENCE($,'Co_30_40_22','Distilleries',#99,$,$); -#107=IFCCLASSIFICATIONREFERENCE($,'Co_30_40_30','Fish processing complexes',#99,$,$); -#108=IFCCLASSIFICATIONREFERENCE($,'Co_30_40_40','Horticultural crop processing complexes',#99,$,$); -#109=IFCCLASSIFICATIONREFERENCE($,'Co_30_40_55','Mills',#99,$,$); -#110=IFCCLASSIFICATIONREFERENCE($,'Co_30_40_60','Livestock processing complexes',#99,$,$); -#111=IFCCLASSIFICATIONREFERENCE($,'Co_30_40_90','Timber processing complexes',#99,$,$); -#112=IFCCLASSIFICATIONREFERENCE($,'Co_30_40_96','Wineries',#99,$,$); -#113=IFCCLASSIFICATIONREFERENCE($,'Co_30_50','Manufacturing complexes',#83,$,$); -#114=IFCCLASSIFICATIONREFERENCE($,'Co_30_50_37','Heavy manufacturing complexes',#113,$,$); -#115=IFCCLASSIFICATIONREFERENCE($,'Co_30_50_41','Industrial parks',#113,$,$); -#116=IFCCLASSIFICATIONREFERENCE($,'Co_30_50_47','Light manufacturing complexes',#113,$,$); -#117=IFCCLASSIFICATIONREFERENCE($,'Co_30_50_77','Ship and boat building yards',#113,$,$); -#118=IFCCLASSIFICATIONREFERENCE($,'Co_30_60','Cleaning and maintenance complexes',#83,$,$); -#119=IFCCLASSIFICATIONREFERENCE($,'Co_30_60_15','Commercial laundries',#118,$,$); -#120=IFCCLASSIFICATIONREFERENCE($,'Co_30_60_94','Vehicle cleaning complexes',#118,$,$); -#121=IFCCLASSIFICATIONREFERENCE($,'Co_30_80','Mechanical power generation complexes',#83,$,$); -#122=IFCCLASSIFICATIONREFERENCE($,'Co_30_80_10','Kinetic power generation complexes',#121,$,$); -#123=IFCCLASSIFICATIONREFERENCE($,'Co_30_85','Marine and water maintenance complexes',#83,$,$); -#124=IFCCLASSIFICATIONREFERENCE($,'Co_30_90','Warehousing and distribution complexes',#83,$,$); -#125=IFCCLASSIFICATIONREFERENCE($,'Co_32','Water and land management complexes',#2,$,$); -#126=IFCCLASSIFICATIONREFERENCE($,'Co_32_10','Agricultural and horticultural complexes',#125,$,$); -#127=IFCCLASSIFICATIONREFERENCE($,'Co_32_10_02','Arable farms',#126,$,$); -#128=IFCCLASSIFICATIONREFERENCE($,'Co_32_10_15','Crofts',#126,$,$); -#129=IFCCLASSIFICATIONREFERENCE($,'Co_32_10_28','Fish farms',#126,$,$); -#130=IFCCLASSIFICATIONREFERENCE($,'Co_32_10_30','Fish hatcheries',#126,$,$); -#131=IFCCLASSIFICATIONREFERENCE($,'Co_32_10_39','Horticultural nurseries',#126,$,$); -#132=IFCCLASSIFICATIONREFERENCE($,'Co_32_10_46','Livestock farms',#126,$,$); -#133=IFCCLASSIFICATIONREFERENCE($,'Co_32_10_50','Managed forests',#126,$,$); -#134=IFCCLASSIFICATIONREFERENCE($,'Co_32_10_58','Orchards',#126,$,$); -#135=IFCCLASSIFICATIONREFERENCE($,'Co_32_10_94','Vineyards',#126,$,$); -#136=IFCCLASSIFICATIONREFERENCE($,'Co_32_20','Designated areas',#125,$,$); -#137=IFCCLASSIFICATIONREFERENCE($,'Co_32_20_04','Areas of special architectural or historical interest',#136,$,$); -#138=IFCCLASSIFICATIONREFERENCE($,'Co_32_20_17','Commons',#136,$,$); -#139=IFCCLASSIFICATIONREFERENCE($,'Co_32_20_22','Designated archaeological sites',#136,$,$); -#140=IFCCLASSIFICATIONREFERENCE($,'Co_32_20_23','Designated nature reserves',#136,$,$); -#141=IFCCLASSIFICATIONREFERENCE($,'Co_32_20_57','National parks',#136,$,$); -#142=IFCCLASSIFICATIONREFERENCE($,'Co_32_50','Marine ways and waterway complexes',#125,$,$); -#143=IFCCLASSIFICATIONREFERENCE($,'Co_32_50_11','Causeways',#142,$,$); -#144=IFCCLASSIFICATIONREFERENCE($,'Co_32_50_48','Lighthouse complexes',#142,$,$); -#145=IFCCLASSIFICATIONREFERENCE($,'Co_32_50_94','Vessel berthing complexes',#142,$,$); -#146=IFCCLASSIFICATIONREFERENCE($,'Co_32_50_95','Vessel launching complexes',#142,$,$); -#147=IFCCLASSIFICATIONREFERENCE($,'Co_32_55','Marine and water protection complexes',#125,$,$); -#148=IFCCLASSIFICATIONREFERENCE($,'Co_32_55_20','Coastal protection complexes',#147,$,$); -#149=IFCCLASSIFICATIONREFERENCE($,'Co_32_55_27','Erosion protection complexes',#147,$,$); -#150=IFCCLASSIFICATIONREFERENCE($,'Co_32_55_30','Flood protection complexes',#147,$,$); -#151=IFCCLASSIFICATIONREFERENCE($,'Co_32_65','Natural areas',#125,$,$); -#152=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_04','Aquifers',#151,$,$); -#153=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_15','Cliffs',#151,$,$); -#154=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_16','Coastal zones',#151,$,$); -#155=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_22','Deserts',#151,$,$); -#156=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_27','Estuaries',#151,$,$); -#157=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_30','Forests',#151,$,$); -#158=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_38','Hills',#151,$,$); -#159=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_46','Lakes',#151,$,$); -#160=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_54','Mountains',#151,$,$); -#161=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_64','Ponds',#151,$,$); -#162=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_72','Rivers',#151,$,$); -#163=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_75','Saltmarshes',#151,$,$); -#164=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_79','Seasonal wetlands',#151,$,$); -#165=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_82','Springs',#151,$,$); -#166=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_85','Streams, brooks and burns',#151,$,$); -#167=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_96','Woodlands',#151,$,$); -#168=IFCCLASSIFICATIONREFERENCE($,'Co_32_85','Water control and retaining complexes',#125,$,$); -#169=IFCCLASSIFICATIONREFERENCE($,'Co_32_85_50','Lock complexes',#168,$,$); -#170=IFCCLASSIFICATIONREFERENCE($,'Co_32_85_70','Reservoirs',#168,$,$); -#171=IFCCLASSIFICATIONREFERENCE($,'Co_32_85_88','Tidal barriers',#168,$,$); -#172=IFCCLASSIFICATIONREFERENCE($,'Co_32_85_96','Water control complexes',#168,$,$); -#173=IFCCLASSIFICATIONREFERENCE($,'Co_32_85_97','Water level and flow monitoring complexes',#168,$,$); -#174=IFCCLASSIFICATIONREFERENCE($,'Co_32_85_98','Water pumping complexes',#168,$,$); -#175=IFCCLASSIFICATIONREFERENCE($,'Co_35','Medical, health, welfare and sanitary complexes',#2,$,$); -#176=IFCCLASSIFICATIONREFERENCE($,'Co_35_10','Medical complexes',#175,$,$); -#177=IFCCLASSIFICATIONREFERENCE($,'Co_35_10_02','Air ambulance complexes',#176,$,$); -#178=IFCCLASSIFICATIONREFERENCE($,'Co_35_10_03','Ambulance complexes',#176,$,$); -#179=IFCCLASSIFICATIONREFERENCE($,'Co_35_10_15','Clinical complexes',#176,$,$); -#180=IFCCLASSIFICATIONREFERENCE($,'Co_35_10_37','Hospital complexes',#176,$,$); -#181=IFCCLASSIFICATIONREFERENCE($,'Co_35_50','Welfare complexes',#175,$,$); -#182=IFCCLASSIFICATIONREFERENCE($,'Co_35_50_30','Fitness and detox complexes',#181,$,$); -#183=IFCCLASSIFICATIONREFERENCE($,'Co_35_50_37','Hospices',#181,$,$); -#184=IFCCLASSIFICATIONREFERENCE($,'Co_35_50_58','Nursing homes',#181,$,$); -#185=IFCCLASSIFICATIONREFERENCE($,'Co_35_50_69','Quarantine stations',#181,$,$); -#186=IFCCLASSIFICATIONREFERENCE($,'Co_35_50_82','Spa complexes',#181,$,$); -#187=IFCCLASSIFICATIONREFERENCE($,'Co_35_50_90','Turkish baths',#181,$,$); -#188=IFCCLASSIFICATIONREFERENCE($,'Co_35_70','Funerary complexes',#175,$,$); -#189=IFCCLASSIFICATIONREFERENCE($,'Co_35_70_13','Cemeteries',#188,$,$); -#190=IFCCLASSIFICATIONREFERENCE($,'Co_35_70_16','Crematoriums',#188,$,$); -#191=IFCCLASSIFICATIONREFERENCE($,'Co_35_70_32','Funeral complexes',#188,$,$); -#192=IFCCLASSIFICATIONREFERENCE($,'Co_35_85','Animal complexes',#175,$,$); -#193=IFCCLASSIFICATIONREFERENCE($,'Co_35_85_02','Animal cage complexes',#192,$,$); -#194=IFCCLASSIFICATIONREFERENCE($,'Co_35_85_03','Animal pen complexes',#192,$,$); -#195=IFCCLASSIFICATIONREFERENCE($,'Co_35_85_04','Aquariums',#192,$,$); -#196=IFCCLASSIFICATIONREFERENCE($,'Co_35_85_05','Aviary complexes',#192,$,$); -#197=IFCCLASSIFICATIONREFERENCE($,'Co_35_85_45','Kennel complexes',#192,$,$); -#198=IFCCLASSIFICATIONREFERENCE($,'Co_35_85_85','Stable complexes',#192,$,$); -#199=IFCCLASSIFICATIONREFERENCE($,'Co_35_90','Animal medical, health, welfare, funerary and sanitary complexes',#175,$,$); -#200=IFCCLASSIFICATIONREFERENCE($,'Co_35_90_02','Animal funerary complexes',#199,$,$); -#201=IFCCLASSIFICATIONREFERENCE($,'Co_35_90_03','Animal quarantine stations',#199,$,$); -#202=IFCCLASSIFICATIONREFERENCE($,'Co_35_90_95','Veterinary hospitals',#199,$,$); -#203=IFCCLASSIFICATIONREFERENCE($,'Co_40','Recreational complexes',#2,$,$); -#204=IFCCLASSIFICATIONREFERENCE($,'Co_40_05','Amusement complexes',#203,$,$); -#205=IFCCLASSIFICATIONREFERENCE($,'Co_40_05_02','Amphitheatres',#204,$,$); -#206=IFCCLASSIFICATIONREFERENCE($,'Co_40_05_03','Amusement parks',#204,$,$); -#207=IFCCLASSIFICATIONREFERENCE($,'Co_40_05_30','Fairground complexes',#204,$,$); -#208=IFCCLASSIFICATIONREFERENCE($,'Co_40_05_63','Pleasure piers',#204,$,$); -#209=IFCCLASSIFICATIONREFERENCE($,'Co_40_05_89','Theme parks',#204,$,$); -#210=IFCCLASSIFICATIONREFERENCE($,'Co_40_35','Historic complexes',#203,$,$); -#211=IFCCLASSIFICATIONREFERENCE($,'Co_40_35_06','Battle sites',#210,$,$); -#212=IFCCLASSIFICATIONREFERENCE($,'Co_40_35_39','Historic sites',#210,$,$); -#213=IFCCLASSIFICATIONREFERENCE($,'Co_40_35_78','Sites of antiquity',#210,$,$); -#214=IFCCLASSIFICATIONREFERENCE($,'Co_40_35_94','Visible earthworks',#210,$,$); -#215=IFCCLASSIFICATIONREFERENCE($,'Co_40_60','Performing arts complexes',#203,$,$); -#216=IFCCLASSIFICATIONREFERENCE($,'Co_40_60_13','Cinema complexes',#215,$,$); -#217=IFCCLASSIFICATIONREFERENCE($,'Co_40_60_14','Circuses',#215,$,$); -#218=IFCCLASSIFICATIONREFERENCE($,'Co_40_60_16','Concert hall complexes',#215,$,$); -#219=IFCCLASSIFICATIONREFERENCE($,'Co_40_60_30','Film and television studio complexes',#215,$,$); -#220=IFCCLASSIFICATIONREFERENCE($,'Co_40_60_88','Theatre complexes',#215,$,$); -#221=IFCCLASSIFICATIONREFERENCE($,'Co_40_75','Social recreation complexes',#203,$,$); -#222=IFCCLASSIFICATIONREFERENCE($,'Co_40_75_15','Community centres',#221,$,$); -#223=IFCCLASSIFICATIONREFERENCE($,'Co_40_75_17','Country parks',#221,$,$); -#224=IFCCLASSIFICATIONREFERENCE($,'Co_40_75_68','Public parks',#221,$,$); -#225=IFCCLASSIFICATIONREFERENCE($,'Co_40_75_71','Recreation grounds',#221,$,$); -#226=IFCCLASSIFICATIONREFERENCE($,'Co_42','Sport and activity complexes',#2,$,$); -#227=IFCCLASSIFICATIONREFERENCE($,'Co_42_40','Indoor activity complexes',#226,$,$); -#228=IFCCLASSIFICATIONREFERENCE($,'Co_42_40_10','Indoor athletics stadiums',#227,$,$); -#229=IFCCLASSIFICATIONREFERENCE($,'Co_42_40_40','Indoor sports complexes',#227,$,$); -#230=IFCCLASSIFICATIONREFERENCE($,'Co_42_50','Outdoor activity complexes',#226,$,$); -#231=IFCCLASSIFICATIONREFERENCE($,'Co_42_50_10','Outdoor athletics stadiums',#230,$,$); -#232=IFCCLASSIFICATIONREFERENCE($,'Co_42_50_30','Golf courses',#230,$,$); -#233=IFCCLASSIFICATIONREFERENCE($,'Co_42_50_60','Outdoor sports complexes',#230,$,$); -#234=IFCCLASSIFICATIONREFERENCE($,'Co_42_50_70','Race horse gallops',#230,$,$); -#235=IFCCLASSIFICATIONREFERENCE($,'Co_42_50_95','Winter sport complexes',#230,$,$); -#236=IFCCLASSIFICATIONREFERENCE($,'Co_42_85','Swimming complexes',#226,$,$); -#237=IFCCLASSIFICATIONREFERENCE($,'Co_42_85_40','Indoor swimming pool complexes',#236,$,$); -#238=IFCCLASSIFICATIONREFERENCE($,'Co_42_85_60','Outdoor swimming pool complexes',#236,$,$); -#239=IFCCLASSIFICATIONREFERENCE($,'Co_42_85_96','Water parks',#236,$,$); -#240=IFCCLASSIFICATIONREFERENCE($,'Co_45','Residential complexes',#2,$,$); -#241=IFCCLASSIFICATIONREFERENCE($,'Co_45_10','Living complexes',#240,$,$); -#242=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_11','Camp sites',#241,$,$); -#243=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_12','Caravan parks',#241,$,$); -#244=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_15','Convents and monasteries',#241,$,$); -#245=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_27','Emergency camps',#241,$,$); -#246=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_35','Halls of residence',#241,$,$); -#247=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_36','High-rise residential complexes',#241,$,$); -#248=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_37','Hostels',#241,$,$); -#249=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_38','Hotels',#241,$,$); -#250=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_40','Houses in multiple occupation',#241,$,$); -#251=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_41','Housing estates',#241,$,$); -#252=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_51','Military camps',#241,$,$); -#253=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_54','Motels',#241,$,$); -#254=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_72','Religious retreats',#241,$,$); -#255=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_74','Residential properties',#241,$,$); -#256=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_78','Sheltered housing',#241,$,$); -#257=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_98','Youth group camps',#241,$,$); -#258=IFCCLASSIFICATIONREFERENCE($,'Co_50','Waste disposal complexes',#2,$,$); -#259=IFCCLASSIFICATIONREFERENCE($,'Co_50_20','Wet waste collection and distribution complexes',#258,$,$); -#260=IFCCLASSIFICATIONREFERENCE($,'Co_50_20_10','Wastewater collection complexes',#259,$,$); -#261=IFCCLASSIFICATIONREFERENCE($,'Co_50_20_20','Wastewater collection networks',#259,$,$); -#262=IFCCLASSIFICATIONREFERENCE($,'Co_50_20_60','Drainage collection networks',#259,$,$); -#263=IFCCLASSIFICATIONREFERENCE($,'Co_50_40','Dry waste collection and distribution complexes',#258,$,$); -#264=IFCCLASSIFICATIONREFERENCE($,'Co_50_40_10','Dry waste collection complexes',#263,$,$); -#265=IFCCLASSIFICATIONREFERENCE($,'Co_50_40_50','Dry waste distribution complexes',#263,$,$); -#266=IFCCLASSIFICATIONREFERENCE($,'Co_50_60','Wet waste treatment and disposal complexes',#258,$,$); -#267=IFCCLASSIFICATIONREFERENCE($,'Co_50_60_40','Wastewater treatment complexes',#266,$,$); -#268=IFCCLASSIFICATIONREFERENCE($,'Co_50_60_80','Drainage disposal networks',#266,$,$); -#269=IFCCLASSIFICATIONREFERENCE($,'Co_50_80','Dry waste treatment and disposal complexes',#258,$,$); -#270=IFCCLASSIFICATIONREFERENCE($,'Co_50_80_40','Dry waste treatment complexes',#269,$,$); -#271=IFCCLASSIFICATIONREFERENCE($,'Co_50_80_70','Dry waste disposal complexes',#269,$,$); -#272=IFCCLASSIFICATIONREFERENCE($,'Co_55','Piped supply complexes',#2,$,$); -#273=IFCCLASSIFICATIONREFERENCE($,'Co_55_05','Gas extraction and treatment complexes',#272,$,$); -#274=IFCCLASSIFICATIONREFERENCE($,'Co_55_05_30','Gas extraction complexes',#273,$,$); -#275=IFCCLASSIFICATIONREFERENCE($,'Co_55_05_70','Gas treatment complexes',#273,$,$); -#276=IFCCLASSIFICATIONREFERENCE($,'Co_55_10','Liquid fuel extraction and treatment complexes',#272,$,$); -#277=IFCCLASSIFICATIONREFERENCE($,'Co_55_10_40','Oil extraction complexes',#276,$,$); -#278=IFCCLASSIFICATIONREFERENCE($,'Co_55_10_80','Oil treatment complexes',#276,$,$); -#279=IFCCLASSIFICATIONREFERENCE($,'Co_55_15','Water extraction and treatment complexes',#272,$,$); -#280=IFCCLASSIFICATIONREFERENCE($,'Co_55_15_10','Water extraction complexes',#279,$,$); -#281=IFCCLASSIFICATIONREFERENCE($,'Co_55_15_50','Water treatment complexes',#279,$,$); -#282=IFCCLASSIFICATIONREFERENCE($,'Co_55_20','Gas supply complexes',#272,$,$); -#283=IFCCLASSIFICATIONREFERENCE($,'Co_55_20_50','Gas distribution complexes',#282,$,$); -#284=IFCCLASSIFICATIONREFERENCE($,'Co_55_20_60','Gas distribution networks',#282,$,$); -#285=IFCCLASSIFICATIONREFERENCE($,'Co_55_50','Liquid fuel supply complexes',#272,$,$); -#286=IFCCLASSIFICATIONREFERENCE($,'Co_55_50_10','Liquid fuel distribution complexes',#285,$,$); -#287=IFCCLASSIFICATIONREFERENCE($,'Co_55_50_50','Liquid fuel distribution networks',#285,$,$); -#288=IFCCLASSIFICATIONREFERENCE($,'Co_55_70','Water supply complexes',#272,$,$); -#289=IFCCLASSIFICATIONREFERENCE($,'Co_55_70_20','Water distribution complexes',#288,$,$); -#290=IFCCLASSIFICATIONREFERENCE($,'Co_55_70_60','Water distribution networks',#288,$,$); -#291=IFCCLASSIFICATIONREFERENCE($,'Co_60','Heating, cooling and refrigeration complexes',#2,$,$); -#292=IFCCLASSIFICATIONREFERENCE($,'Co_60_10','Heating complexes',#291,$,$); -#293=IFCCLASSIFICATIONREFERENCE($,'Co_60_10_10','District heating complexes',#292,$,$); -#294=IFCCLASSIFICATIONREFERENCE($,'Co_60_40','Cooling complexes',#291,$,$); -#295=IFCCLASSIFICATIONREFERENCE($,'Co_60_40_10','District cooling complexes',#294,$,$); -#296=IFCCLASSIFICATIONREFERENCE($,'Co_65','Ventilation and air conditioning complexes',#2,$,$); -#297=IFCCLASSIFICATIONREFERENCE($,'Co_70','Electrical power generation and distribution complexes',#2,$,$); -#298=IFCCLASSIFICATIONREFERENCE($,'Co_70_10','Electrical power generation complexes',#297,$,$); -#299=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_08','Biomass power generation complexes',#298,$,$); -#300=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_16','Coal power generation complexes',#298,$,$); -#301=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_17','Combined heat and power generation complexes',#298,$,$); -#302=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_33','Gas power generation complexes',#298,$,$); -#303=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_34','Geothermal power generation complexes',#298,$,$); -#304=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_38','Hydroelectric power generation complexes',#298,$,$); -#305=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_57','Nuclear power generation complexes',#298,$,$); -#306=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_58','Offshore wind power generation complexes',#298,$,$); -#307=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_59','Oil-fired power generation complexes',#298,$,$); -#308=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_60','Onshore wind power generation complexes',#298,$,$); -#309=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_63','Photovoltaic power generation complexes',#298,$,$); -#310=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_81','Solar reflector power generation complexes',#298,$,$); -#311=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_88','Tidal power generation complexes',#298,$,$); -#312=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_96','Wave power generation complexes',#298,$,$); -#313=IFCCLASSIFICATIONREFERENCE($,'Co_70_30','Electricity distribution complexes',#297,$,$); -#314=IFCCLASSIFICATIONREFERENCE($,'Co_70_30_35','High voltage electricity substation complexes',#313,$,$); -#315=IFCCLASSIFICATIONREFERENCE($,'Co_70_30_40','High voltage electricity networks',#313,$,$); -#316=IFCCLASSIFICATIONREFERENCE($,'Co_70_30_45','Low voltage electricity substation complexes',#313,$,$); -#317=IFCCLASSIFICATIONREFERENCE($,'Co_70_30_50','Low voltage electricity networks',#313,$,$); -#318=IFCCLASSIFICATIONREFERENCE($,'Co_75','Communications, security, safety and protection complexes',#2,$,$); -#319=IFCCLASSIFICATIONREFERENCE($,'Co_75_10','Communications complexes',#318,$,$); -#320=IFCCLASSIFICATIONREFERENCE($,'Co_75_10_10','Broadcast communications complexes',#319,$,$); -#321=IFCCLASSIFICATIONREFERENCE($,'Co_75_10_20','Broadcast communications networks',#319,$,$); -#322=IFCCLASSIFICATIONREFERENCE($,'Co_75_10_80','Telecommunications complexes',#319,$,$); -#323=IFCCLASSIFICATIONREFERENCE($,'Co_75_10_90','Telecommunications networks',#319,$,$); -#324=IFCCLASSIFICATIONREFERENCE($,'Co_80','Transport complexes',#2,$,$); -#325=IFCCLASSIFICATIONREFERENCE($,'Co_80_05','Aerospace complexes',#324,$,$); -#326=IFCCLASSIFICATIONREFERENCE($,'Co_80_05_02','Airports and airfields',#325,$,$); -#327=IFCCLASSIFICATIONREFERENCE($,'Co_80_05_38','Heliports',#325,$,$); -#328=IFCCLASSIFICATIONREFERENCE($,'Co_80_05_84','Spacecraft complexes',#325,$,$); -#329=IFCCLASSIFICATIONREFERENCE($,'Co_80_20','Cable transport complexes',#324,$,$); -#330=IFCCLASSIFICATIONREFERENCE($,'Co_80_20_02','Aerial tramway complexes',#329,$,$); -#331=IFCCLASSIFICATIONREFERENCE($,'Co_80_20_10','Cable railway complexes',#329,$,$); -#332=IFCCLASSIFICATIONREFERENCE($,'Co_80_20_13','Chairlift way complexes',#329,$,$); -#333=IFCCLASSIFICATIONREFERENCE($,'Co_80_20_32','Funicular railway complexes',#329,$,$); -#334=IFCCLASSIFICATIONREFERENCE($,'Co_80_20_34','Gondola lift way complexes',#329,$,$); -#335=IFCCLASSIFICATIONREFERENCE($,'Co_80_20_84','Surface lift way complexes',#329,$,$); -#336=IFCCLASSIFICATIONREFERENCE($,'Co_80_20_99','Zip line way complexes',#329,$,$); -#337=IFCCLASSIFICATIONREFERENCE($,'Co_80_35','Road complexes',#324,$,$); -#338=IFCCLASSIFICATIONREFERENCE($,'Co_80_35_10','Bus route networks',#337,$,$); -#339=IFCCLASSIFICATIONREFERENCE($,'Co_80_35_75','Road networks',#337,$,$); -#340=IFCCLASSIFICATIONREFERENCE($,'Co_80_50','Railway complexes',#324,$,$); -#341=IFCCLASSIFICATIONREFERENCE($,'Co_80_50_35','Heavy rail complexes',#340,$,$); -#342=IFCCLASSIFICATIONREFERENCE($,'Co_80_50_37','High-speed rail complexes',#340,$,$); -#343=IFCCLASSIFICATIONREFERENCE($,'Co_80_50_45','Light rail complexes',#340,$,$); -#344=IFCCLASSIFICATIONREFERENCE($,'Co_80_50_50','Magnetic levitation ways',#340,$,$); -#345=IFCCLASSIFICATIONREFERENCE($,'Co_80_50_53','Monorail complexes',#340,$,$); -#346=IFCCLASSIFICATIONREFERENCE($,'Co_80_50_56','Narrow-gauge rail complexes',#340,$,$); -#347=IFCCLASSIFICATIONREFERENCE($,'Co_80_50_69','Rack rail complexes',#340,$,$); -#348=IFCCLASSIFICATIONREFERENCE($,'Co_80_50_76','Road-based light rail complexes',#340,$,$); -#349=IFCCLASSIFICATIONREFERENCE($,'Co_80_70','Marine and waterways transport complexes',#324,$,$); -#350=IFCCLASSIFICATIONREFERENCE($,'Co_80_70_11','Cable ferry complexes',#349,$,$); -#351=IFCCLASSIFICATIONREFERENCE($,'Co_80_70_13','Canal complexes',#349,$,$); -#352=IFCCLASSIFICATIONREFERENCE($,'Co_80_70_17','Container ports',#349,$,$); -#353=IFCCLASSIFICATIONREFERENCE($,'Co_80_70_23','Dry bulk ports',#349,$,$); -#354=IFCCLASSIFICATIONREFERENCE($,'Co_80_70_30','Fishing ports',#349,$,$); -#355=IFCCLASSIFICATIONREFERENCE($,'Co_80_70_36','Harbours',#349,$,$); -#356=IFCCLASSIFICATIONREFERENCE($,'Co_80_70_47','Liquid bulk ports',#349,$,$); -#357=IFCCLASSIFICATIONREFERENCE($,'Co_80_70_72','Roll-on roll-off ports',#349,$,$); -#358=IFCCLASSIFICATIONREFERENCE($,'Co_80_70_77','Sea cruise ports',#349,$,$); -#359=IFCCLASSIFICATIONREFERENCE($,'Co_80_70_78','Sea ferry ports',#349,$,$); -#360=IFCCLASSIFICATIONREFERENCE($,'Co_80_70_96','Waterway ferry complexes',#349,$,$); -#361=IFCCLASSIFICATIONREFERENCE($,'Co_80_90','Transport interchange complexes',#324,$,$); -#362=IFCCLASSIFICATIONREFERENCE($,'Co_90','Circulation and storage complexes',#2,$,$); -#363=IFCCLASSIFICATIONREFERENCE($,'Co_90_50','Storage complexes',#362,$,$); -#364=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_03','Ambient food storage complexes',#363,$,$); -#365=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_04','Arms storage complexes',#363,$,$); -#366=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_15','Cold storage complexes',#363,$,$); -#367=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_16','Complexes for the storage of human remains',#363,$,$); -#368=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_24','Dry waste storage complexes',#363,$,$); -#369=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_34','Gas storage complexes',#363,$,$); -#370=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_45','Liquid fuel storage complexes',#363,$,$); -#371=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_51','Military arsenals',#363,$,$); -#372=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_52','Mineral storage complexes',#363,$,$); -#373=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_71','Refrigerated food storage complexes',#363,$,$); -#374=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_77','Secure storage complexes',#363,$,$); -#375=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_78','Self storage complexes',#363,$,$); -#376=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_80','Solid fuel storage complexes',#363,$,$); -#377=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_94','Warehouses',#363,$,$); -#378=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_95','Wastewater storage complexes',#363,$,$); -#379=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_96','Water storage complexes',#363,$,$); -#380=IFCCLASSIFICATIONREFERENCE($,'Co_90_90','Plant and control complexes',#362,$,$); -#381=IFCCLASSIFICATIONREFERENCE($,'Co_90_90_50','Multiple services plant and equipment complexes',#380,$,$); -#382=IFCCLASSIFICATIONREFERENCE($,'En','Entities',#1,$,$); -#383=IFCCLASSIFICATIONREFERENCE($,'En_20','Administrative, commercial and protective service entities',#382,$,$); -#384=IFCCLASSIFICATIONREFERENCE($,'En_20_10','Legislative entities',#383,$,$); -#385=IFCCLASSIFICATIONREFERENCE($,'En_20_10_45','Governmental buildings',#384,$,$); -#386=IFCCLASSIFICATIONREFERENCE($,'En_20_15','Administrative office entities',#383,$,$); -#387=IFCCLASSIFICATIONREFERENCE($,'En_20_15_10','Multiple occupation office buildings',#386,$,$); -#388=IFCCLASSIFICATIONREFERENCE($,'En_20_15_70','Single occupation office buildings',#386,$,$); -#389=IFCCLASSIFICATIONREFERENCE($,'En_20_20','Secular representative entities',#383,$,$); -#390=IFCCLASSIFICATIONREFERENCE($,'En_20_20_10','Buildings for representatives of nation states abroad',#389,$,$); -#391=IFCCLASSIFICATIONREFERENCE($,'En_20_20_40','Local government buildings',#389,$,$); -#392=IFCCLASSIFICATIONREFERENCE($,'En_20_20_50','National government buildings',#389,$,$); -#393=IFCCLASSIFICATIONREFERENCE($,'En_20_20_70','Regional government buildings',#389,$,$); -#394=IFCCLASSIFICATIONREFERENCE($,'En_20_45','Motor vehicle maintenance and fuelling entities',#383,$,$); -#395=IFCCLASSIFICATIONREFERENCE($,'En_20_45_50','Motor vehicle fuelling and charging entities',#394,$,$); -#396=IFCCLASSIFICATIONREFERENCE($,'En_20_45_54','Motor vehicle servicing and repair entities',#394,$,$); -#397=IFCCLASSIFICATIONREFERENCE($,'En_20_50','Commercial entities',#383,$,$); -#398=IFCCLASSIFICATIONREFERENCE($,'En_20_50_05','Auction buildings',#397,$,$); -#399=IFCCLASSIFICATIONREFERENCE($,'En_20_50_22','Department stores',#397,$,$); -#400=IFCCLASSIFICATIONREFERENCE($,'En_20_50_29','Financial and professional services buildings',#397,$,$); -#401=IFCCLASSIFICATIONREFERENCE($,'En_20_50_50','Markets',#397,$,$); -#402=IFCCLASSIFICATIONREFERENCE($,'En_20_50_53','Mixed use buildings',#397,$,$); -#403=IFCCLASSIFICATIONREFERENCE($,'En_20_50_55','Motor vehicle sales entities',#397,$,$); -#404=IFCCLASSIFICATIONREFERENCE($,'En_20_50_80','Shop units',#397,$,$); -#405=IFCCLASSIFICATIONREFERENCE($,'En_20_50_85','Supermarkets',#397,$,$); -#406=IFCCLASSIFICATIONREFERENCE($,'En_20_50_97','Wholesale buildings',#397,$,$); -#407=IFCCLASSIFICATIONREFERENCE($,'En_20_55','Postal communications entities',#383,$,$); -#408=IFCCLASSIFICATIONREFERENCE($,'En_20_55_65','Post office buildings',#407,$,$); -#409=IFCCLASSIFICATIONREFERENCE($,'En_20_55_80','Sorting office buildings',#407,$,$); -#410=IFCCLASSIFICATIONREFERENCE($,'En_20_60','Military entities',#383,$,$); -#411=IFCCLASSIFICATIONREFERENCE($,'En_20_60_02','Air force buildings',#410,$,$); -#412=IFCCLASSIFICATIONREFERENCE($,'En_20_60_10','Army buildings',#410,$,$); -#413=IFCCLASSIFICATIONREFERENCE($,'En_20_60_56','Navy buildings',#410,$,$); -#414=IFCCLASSIFICATIONREFERENCE($,'En_20_65','Law enforcement operational entities',#383,$,$); -#415=IFCCLASSIFICATIONREFERENCE($,'En_20_65_09','Police buildings',#414,$,$); -#416=IFCCLASSIFICATIONREFERENCE($,'En_20_70','Judicial entities',#383,$,$); -#417=IFCCLASSIFICATIONREFERENCE($,'En_20_70_40','Law court buildings',#416,$,$); -#418=IFCCLASSIFICATIONREFERENCE($,'En_20_75','Detention entities',#383,$,$); -#419=IFCCLASSIFICATIONREFERENCE($,'En_20_75_10','Detention buildings',#418,$,$); -#420=IFCCLASSIFICATIONREFERENCE($,'En_20_80','Weapons training ranges',#383,$,$); -#421=IFCCLASSIFICATIONREFERENCE($,'En_20_80_29','Firing range buildings',#420,$,$); -#422=IFCCLASSIFICATIONREFERENCE($,'En_20_80_30','Exterior firing ranges',#420,$,$); -#423=IFCCLASSIFICATIONREFERENCE($,'En_20_85','Security entities',#383,$,$); -#424=IFCCLASSIFICATIONREFERENCE($,'En_20_85_15','Security control buildings',#423,$,$); -#425=IFCCLASSIFICATIONREFERENCE($,'En_20_85_30','Security fences',#423,$,$); -#426=IFCCLASSIFICATIONREFERENCE($,'En_20_90','Incident support entities',#383,$,$); -#427=IFCCLASSIFICATIONREFERENCE($,'En_20_90_10','Fire and rescue training buildings',#426,$,$); -#428=IFCCLASSIFICATIONREFERENCE($,'En_20_90_15','Fire station buildings',#426,$,$); -#429=IFCCLASSIFICATIONREFERENCE($,'En_25','Cultural, educational, scientific and information entities',#382,$,$); -#430=IFCCLASSIFICATIONREFERENCE($,'En_25_05','Commemoration entities',#429,$,$); -#431=IFCCLASSIFICATIONREFERENCE($,'En_25_05_35','Gardens of remembrance',#430,$,$); -#432=IFCCLASSIFICATIONREFERENCE($,'En_25_05_50','Memorials',#430,$,$); -#433=IFCCLASSIFICATIONREFERENCE($,'En_25_05_55','Monuments',#430,$,$); -#434=IFCCLASSIFICATIONREFERENCE($,'En_25_10','Educational entities',#429,$,$); -#435=IFCCLASSIFICATIONREFERENCE($,'En_25_10_10','Pre-school educational buildings',#434,$,$); -#436=IFCCLASSIFICATIONREFERENCE($,'En_25_10_20','Infant educational buildings',#434,$,$); -#437=IFCCLASSIFICATIONREFERENCE($,'En_25_10_30','Primary educational buildings',#434,$,$); -#438=IFCCLASSIFICATIONREFERENCE($,'En_25_10_40','Secondary educational buildings',#434,$,$); -#439=IFCCLASSIFICATIONREFERENCE($,'En_25_10_50','Pre-tertiary educational buildings',#434,$,$); -#440=IFCCLASSIFICATIONREFERENCE($,'En_25_10_60','Tertiary educational buildings',#434,$,$); -#441=IFCCLASSIFICATIONREFERENCE($,'En_25_10_70','Adult educational buildings',#434,$,$); -#442=IFCCLASSIFICATIONREFERENCE($,'En_25_30','Scientific and laboratory entities',#429,$,$); -#443=IFCCLASSIFICATIONREFERENCE($,'En_25_30_40','Laboratory buildings',#442,$,$); -#444=IFCCLASSIFICATIONREFERENCE($,'En_25_30_50','Meteorological stations',#442,$,$); -#445=IFCCLASSIFICATIONREFERENCE($,'En_25_30_60','Observatory buildings',#442,$,$); -#446=IFCCLASSIFICATIONREFERENCE($,'En_25_30_66','Observatory antennas',#442,$,$); -#447=IFCCLASSIFICATIONREFERENCE($,'En_25_30_70','Research buildings',#442,$,$); -#448=IFCCLASSIFICATIONREFERENCE($,'En_25_30_77','Seed banks',#442,$,$); -#449=IFCCLASSIFICATIONREFERENCE($,'En_25_30_90','Triangulation pillars',#442,$,$); -#450=IFCCLASSIFICATIONREFERENCE($,'En_25_50','Exhibition entities',#429,$,$); -#451=IFCCLASSIFICATIONREFERENCE($,'En_25_50_02','Art exhibition buildings',#450,$,$); -#452=IFCCLASSIFICATIONREFERENCE($,'En_25_50_04','Art installations',#450,$,$); -#453=IFCCLASSIFICATIONREFERENCE($,'En_25_50_15','Collection exhibition buildings',#450,$,$); -#454=IFCCLASSIFICATIONREFERENCE($,'En_25_50_29','Fauna exhibition buildings',#450,$,$); -#455=IFCCLASSIFICATIONREFERENCE($,'En_25_50_30','Fauna exhibition grounds',#450,$,$); -#456=IFCCLASSIFICATIONREFERENCE($,'En_25_50_31','Flora exhibition buildings',#450,$,$); -#457=IFCCLASSIFICATIONREFERENCE($,'En_25_50_32','Flora exhibition grounds',#450,$,$); -#458=IFCCLASSIFICATIONREFERENCE($,'En_25_50_54','Multipurpose exhibition buildings',#450,$,$); -#459=IFCCLASSIFICATIONREFERENCE($,'En_25_70','Information entities',#429,$,$); -#460=IFCCLASSIFICATIONREFERENCE($,'En_25_70_02','Archive buildings',#459,$,$); -#461=IFCCLASSIFICATIONREFERENCE($,'En_25_70_13','Conference buildings',#459,$,$); -#462=IFCCLASSIFICATIONREFERENCE($,'En_25_70_42','Information kiosks',#459,$,$); -#463=IFCCLASSIFICATIONREFERENCE($,'En_25_70_47','Library buildings',#459,$,$); -#464=IFCCLASSIFICATIONREFERENCE($,'En_25_90','Worship entities',#429,$,$); -#465=IFCCLASSIFICATIONREFERENCE($,'En_25_90_30','Faith worship buildings',#464,$,$); -#466=IFCCLASSIFICATIONREFERENCE($,'En_30','Industrial entities',#382,$,$); -#467=IFCCLASSIFICATIONREFERENCE($,'En_30_10','Mineral extraction entities',#466,$,$); -#468=IFCCLASSIFICATIONREFERENCE($,'En_30_10_57','Offshore oil and gas extraction platforms',#467,$,$); -#469=IFCCLASSIFICATIONREFERENCE($,'En_30_10_80','Spoil heaps',#467,$,$); -#470=IFCCLASSIFICATIONREFERENCE($,'En_30_10_85','Surface mining structures',#467,$,$); -#471=IFCCLASSIFICATIONREFERENCE($,'En_30_10_86','Surface mining cuttings',#467,$,$); -#472=IFCCLASSIFICATIONREFERENCE($,'En_30_10_90','Underground mining structures',#467,$,$); -#473=IFCCLASSIFICATIONREFERENCE($,'En_30_20','Nuclear and chemical management entities',#466,$,$); -#474=IFCCLASSIFICATIONREFERENCE($,'En_30_20_15','Radioactivity waste management control buildings',#473,$,$); -#475=IFCCLASSIFICATIONREFERENCE($,'En_30_20_30','High heat generating radioactive waste management tunnel',#473,$,$); -#476=IFCCLASSIFICATIONREFERENCE($,'En_30_20_35','High heat radioactive waste package transfer buildings',#473,$,$); -#477=IFCCLASSIFICATIONREFERENCE($,'En_30_20_45','Low heat radioactive waste package transfer buildings',#473,$,$); -#478=IFCCLASSIFICATIONREFERENCE($,'En_30_20_60','Low heat generating radioactive waste management vault',#473,$,$); -#479=IFCCLASSIFICATIONREFERENCE($,'En_30_20_70','Radioactivity decontamination buildings',#473,$,$); -#480=IFCCLASSIFICATIONREFERENCE($,'En_30_20_75','Radioactivity effluent management buildings',#473,$,$); -#481=IFCCLASSIFICATIONREFERENCE($,'En_30_30','Mineral processing entities',#466,$,$); -#482=IFCCLASSIFICATIONREFERENCE($,'En_30_30_33','Gas processing structures',#481,$,$); -#483=IFCCLASSIFICATIONREFERENCE($,'En_30_30_58','Oil processing structures',#481,$,$); -#484=IFCCLASSIFICATIONREFERENCE($,'En_30_30_59','Ore processing structures',#481,$,$); -#485=IFCCLASSIFICATIONREFERENCE($,'En_30_40','Animal and plant products processing entities',#466,$,$); -#486=IFCCLASSIFICATIONREFERENCE($,'En_30_40_01','Animal processing buildings',#485,$,$); -#487=IFCCLASSIFICATIONREFERENCE($,'En_30_40_20','Crop processing buildings',#485,$,$); -#488=IFCCLASSIFICATIONREFERENCE($,'En_30_40_30','Fish processing buildings',#485,$,$); -#489=IFCCLASSIFICATIONREFERENCE($,'En_30_40_40','Horticultural processing buildings',#485,$,$); -#490=IFCCLASSIFICATIONREFERENCE($,'En_30_40_90','Timber processing buildings',#485,$,$); -#491=IFCCLASSIFICATIONREFERENCE($,'En_30_50','Manufacturing entities',#466,$,$); -#492=IFCCLASSIFICATIONREFERENCE($,'En_30_50_15','Cranes',#491,$,$); -#493=IFCCLASSIFICATIONREFERENCE($,'En_30_50_50','Manufacturing buildings',#491,$,$); -#494=IFCCLASSIFICATIONREFERENCE($,'En_30_60','Cleaning and maintenance entities',#466,$,$); -#495=IFCCLASSIFICATIONREFERENCE($,'En_30_60_20','Decontamination laundry buildings',#494,$,$); -#496=IFCCLASSIFICATIONREFERENCE($,'En_30_60_40','Laundry buildings',#494,$,$); -#497=IFCCLASSIFICATIONREFERENCE($,'En_30_60_50','Maintenance buildings',#494,$,$); -#498=IFCCLASSIFICATIONREFERENCE($,'En_30_60_94','Vehicle cleaning buildings',#494,$,$); -#499=IFCCLASSIFICATIONREFERENCE($,'En_30_70','Process entities',#466,$,$); -#500=IFCCLASSIFICATIONREFERENCE($,'En_30_70_13','Chimney stacks',#499,$,$); -#501=IFCCLASSIFICATIONREFERENCE($,'En_30_70_15','Conveyors',#499,$,$); -#502=IFCCLASSIFICATIONREFERENCE($,'En_30_70_17','Cooling towers',#499,$,$); -#503=IFCCLASSIFICATIONREFERENCE($,'En_30_70_28','Equipment gantries',#499,$,$); -#504=IFCCLASSIFICATIONREFERENCE($,'En_30_80','Mechanical power generation',#466,$,$); -#505=IFCCLASSIFICATIONREFERENCE($,'En_30_80_96','Watermills',#504,$,$); -#506=IFCCLASSIFICATIONREFERENCE($,'En_30_80_97','Windmills',#504,$,$); -#507=IFCCLASSIFICATIONREFERENCE($,'En_30_85','Marine and water entities',#466,$,$); -#508=IFCCLASSIFICATIONREFERENCE($,'En_30_85_07','Boathouse buildings',#507,$,$); -#509=IFCCLASSIFICATIONREFERENCE($,'En_30_85_08','Boatyard buildings',#507,$,$); -#510=IFCCLASSIFICATIONREFERENCE($,'En_30_85_24','Dry docks',#507,$,$); -#511=IFCCLASSIFICATIONREFERENCE($,'En_30_85_80','Shipyard buildings',#507,$,$); -#512=IFCCLASSIFICATIONREFERENCE($,'En_30_90','Warehousing and distribution entities',#466,$,$); -#513=IFCCLASSIFICATIONREFERENCE($,'En_30_90_33','Goods warehousing buildings',#512,$,$); -#514=IFCCLASSIFICATIONREFERENCE($,'En_30_90_35','Goods distribution buildings',#512,$,$); -#515=IFCCLASSIFICATIONREFERENCE($,'En_32','Water and land management entities',#382,$,$); -#516=IFCCLASSIFICATIONREFERENCE($,'En_32_10','Agricultural and horticultural entities',#515,$,$); -#517=IFCCLASSIFICATIONREFERENCE($,'En_32_10_02','Arable buildings',#516,$,$); -#518=IFCCLASSIFICATIONREFERENCE($,'En_32_10_04','Arable land',#516,$,$); -#519=IFCCLASSIFICATIONREFERENCE($,'En_32_10_20','Coppices',#516,$,$); -#520=IFCCLASSIFICATIONREFERENCE($,'En_32_10_28','Fishing buildings',#516,$,$); -#521=IFCCLASSIFICATIONREFERENCE($,'En_32_10_29','Fishing cages',#516,$,$); -#522=IFCCLASSIFICATIONREFERENCE($,'En_32_10_30','Forestry buildings',#516,$,$); -#523=IFCCLASSIFICATIONREFERENCE($,'En_32_10_31','Forestry plantations',#516,$,$); -#524=IFCCLASSIFICATIONREFERENCE($,'En_32_10_39','Horticultural buildings',#516,$,$); -#525=IFCCLASSIFICATIONREFERENCE($,'En_32_10_40','Horticultural land',#516,$,$); -#526=IFCCLASSIFICATIONREFERENCE($,'En_32_10_46','Livestock buildings',#516,$,$); -#527=IFCCLASSIFICATIONREFERENCE($,'En_32_10_47','Livestock paddocks and fields',#516,$,$); -#528=IFCCLASSIFICATIONREFERENCE($,'En_32_10_93','Vineyard and winery buildings',#516,$,$); -#529=IFCCLASSIFICATIONREFERENCE($,'En_32_10_94','Vineyard plantations',#516,$,$); -#530=IFCCLASSIFICATIONREFERENCE($,'En_32_35','Grounds',#515,$,$); -#531=IFCCLASSIFICATIONREFERENCE($,'En_32_35_05','Arboretums',#530,$,$); -#532=IFCCLASSIFICATIONREFERENCE($,'En_32_35_12','Botanical gardens',#530,$,$); -#533=IFCCLASSIFICATIONREFERENCE($,'En_32_35_15','Community gardens',#530,$,$); -#534=IFCCLASSIFICATIONREFERENCE($,'En_32_35_33','Gardens',#530,$,$); -#535=IFCCLASSIFICATIONREFERENCE($,'En_32_35_36','Hard landscapes',#530,$,$); -#536=IFCCLASSIFICATIONREFERENCE($,'En_32_35_80','Soft landscapes',#530,$,$); -#537=IFCCLASSIFICATIONREFERENCE($,'En_32_40','Land managed entities',#515,$,$); -#538=IFCCLASSIFICATIONREFERENCE($,'En_32_40_20','Cuttings',#537,$,$); -#539=IFCCLASSIFICATIONREFERENCE($,'En_32_40_26','Embankments',#537,$,$); -#540=IFCCLASSIFICATIONREFERENCE($,'En_32_40_30','False cuttings',#537,$,$); -#541=IFCCLASSIFICATIONREFERENCE($,'En_32_40_90','Trenches',#537,$,$); -#542=IFCCLASSIFICATIONREFERENCE($,'En_32_50','Marine and water side entities',#515,$,$); -#543=IFCCLASSIFICATIONREFERENCE($,'En_32_50_20','Degaussing and acoustic ranges',#542,$,$); -#544=IFCCLASSIFICATIONREFERENCE($,'En_32_50_22','Dock buildings',#542,$,$); -#545=IFCCLASSIFICATIONREFERENCE($,'En_32_50_44','Jetties',#542,$,$); -#546=IFCCLASSIFICATIONREFERENCE($,'En_32_50_46','Landing stages',#542,$,$); -#547=IFCCLASSIFICATIONREFERENCE($,'En_32_50_58','Offshore anchorages',#542,$,$); -#548=IFCCLASSIFICATIONREFERENCE($,'En_32_50_63','Piers',#542,$,$); -#549=IFCCLASSIFICATIONREFERENCE($,'En_32_50_69','Quays',#542,$,$); -#550=IFCCLASSIFICATIONREFERENCE($,'En_32_50_98','Wharfs',#542,$,$); -#551=IFCCLASSIFICATIONREFERENCE($,'En_32_85','Water control and retaining entities',#515,$,$); -#552=IFCCLASSIFICATIONREFERENCE($,'En_32_85_06','Barrier beaches',#551,$,$); -#553=IFCCLASSIFICATIONREFERENCE($,'En_32_85_10','Breakwaters',#551,$,$); -#554=IFCCLASSIFICATIONREFERENCE($,'En_32_85_15','Control gates',#551,$,$); -#555=IFCCLASSIFICATIONREFERENCE($,'En_32_85_21','Dams',#551,$,$); -#556=IFCCLASSIFICATIONREFERENCE($,'En_32_85_23','Debris screens',#551,$,$); -#557=IFCCLASSIFICATIONREFERENCE($,'En_32_85_24','Dolphins',#551,$,$); -#558=IFCCLASSIFICATIONREFERENCE($,'En_32_85_25','Draw-off towers',#551,$,$); -#559=IFCCLASSIFICATIONREFERENCE($,'En_32_85_30','Flood prevention structures',#551,$,$); -#560=IFCCLASSIFICATIONREFERENCE($,'En_32_85_31','Flumes',#551,$,$); -#561=IFCCLASSIFICATIONREFERENCE($,'En_32_85_35','Groynes',#551,$,$); -#562=IFCCLASSIFICATIONREFERENCE($,'En_32_85_37','High ground',#551,$,$); -#563=IFCCLASSIFICATIONREFERENCE($,'En_32_85_45','Levees',#551,$,$); -#564=IFCCLASSIFICATIONREFERENCE($,'En_32_85_59','Outfalls',#551,$,$); -#565=IFCCLASSIFICATIONREFERENCE($,'En_32_85_72','Revetments',#551,$,$); -#566=IFCCLASSIFICATIONREFERENCE($,'En_32_85_77','Sea dikes',#551,$,$); -#567=IFCCLASSIFICATIONREFERENCE($,'En_32_85_80','Sluices',#551,$,$); -#568=IFCCLASSIFICATIONREFERENCE($,'En_32_85_82','Spillways',#551,$,$); -#569=IFCCLASSIFICATIONREFERENCE($,'En_32_85_84','Stilling basins',#551,$,$); -#570=IFCCLASSIFICATIONREFERENCE($,'En_32_85_96','Water retaining structures',#551,$,$); -#571=IFCCLASSIFICATIONREFERENCE($,'En_32_85_97','Weirs',#551,$,$); -#572=IFCCLASSIFICATIONREFERENCE($,'En_32_85_98','Wells',#551,$,$); -#573=IFCCLASSIFICATIONREFERENCE($,'En_32_95','Waterways',#515,$,$); -#574=IFCCLASSIFICATIONREFERENCE($,'En_32_95_14','Channels',#573,$,$); -#575=IFCCLASSIFICATIONREFERENCE($,'En_32_95_16','Complex culverts',#573,$,$); -#576=IFCCLASSIFICATIONREFERENCE($,'En_32_95_23','Ditches',#573,$,$); -#577=IFCCLASSIFICATIONREFERENCE($,'En_32_95_59','Open channels',#573,$,$); -#578=IFCCLASSIFICATIONREFERENCE($,'En_32_95_80','Simple culverts',#573,$,$); -#579=IFCCLASSIFICATIONREFERENCE($,'En_32_95_85','Surface water channels',#573,$,$); -#580=IFCCLASSIFICATIONREFERENCE($,'En_32_95_86','Swales',#573,$,$); -#581=IFCCLASSIFICATIONREFERENCE($,'En_35','Medical, health, welfare and sanitary entities',#382,$,$); -#582=IFCCLASSIFICATIONREFERENCE($,'En_35_10','Medical entities',#581,$,$); -#583=IFCCLASSIFICATIONREFERENCE($,'En_35_10_10','Medical buildings',#582,$,$); -#584=IFCCLASSIFICATIONREFERENCE($,'En_35_50','Welfare entities',#581,$,$); -#585=IFCCLASSIFICATIONREFERENCE($,'En_35_50_21','Day welfare buildings',#584,$,$); -#586=IFCCLASSIFICATIONREFERENCE($,'En_35_50_70','Residential welfare buildings',#584,$,$); -#587=IFCCLASSIFICATIONREFERENCE($,'En_35_50_94','Visitor welfare buildings',#584,$,$); -#588=IFCCLASSIFICATIONREFERENCE($,'En_35_70','Funerary entities',#581,$,$); -#589=IFCCLASSIFICATIONREFERENCE($,'En_35_70_06','Body storage buildings',#588,$,$); -#590=IFCCLASSIFICATIONREFERENCE($,'En_35_70_10','Burial buildings',#588,$,$); -#591=IFCCLASSIFICATIONREFERENCE($,'En_35_70_11','Burial grounds',#588,$,$); -#592=IFCCLASSIFICATIONREFERENCE($,'En_35_70_30','Funeral buildings',#588,$,$); -#593=IFCCLASSIFICATIONREFERENCE($,'En_35_70_60','Medical chimney stacks',#588,$,$); -#594=IFCCLASSIFICATIONREFERENCE($,'En_35_80','Sanitary entities',#581,$,$); -#595=IFCCLASSIFICATIONREFERENCE($,'En_35_80_10','Bathing buildings',#594,$,$); -#596=IFCCLASSIFICATIONREFERENCE($,'En_35_80_90','Toilet buildings',#594,$,$); -#597=IFCCLASSIFICATIONREFERENCE($,'En_35_85','Animal entities',#581,$,$); -#598=IFCCLASSIFICATIONREFERENCE($,'En_35_85_02','Animal cage buildings',#597,$,$); -#599=IFCCLASSIFICATIONREFERENCE($,'En_35_85_03','Animal pen buildings',#597,$,$); -#600=IFCCLASSIFICATIONREFERENCE($,'En_35_85_84','Stable buildings',#597,$,$); -#601=IFCCLASSIFICATIONREFERENCE($,'En_35_90','Animal medical, health, welfare and funerary entities',#581,$,$); -#602=IFCCLASSIFICATIONREFERENCE($,'En_35_90_10','Animal cemeteries',#601,$,$); -#603=IFCCLASSIFICATIONREFERENCE($,'En_35_90_30','Animal funerary buildings',#601,$,$); -#604=IFCCLASSIFICATIONREFERENCE($,'En_35_90_50','Animal medical buildings',#601,$,$); -#605=IFCCLASSIFICATIONREFERENCE($,'En_40','Recreational entities',#382,$,$); -#606=IFCCLASSIFICATIONREFERENCE($,'En_40_05','Amusement entities',#605,$,$); -#607=IFCCLASSIFICATIONREFERENCE($,'En_40_05_03','Amusement buildings',#606,$,$); -#608=IFCCLASSIFICATIONREFERENCE($,'En_40_05_13','Casinos',#606,$,$); -#609=IFCCLASSIFICATIONREFERENCE($,'En_40_05_42','Indoor fairgrounds',#606,$,$); -#610=IFCCLASSIFICATIONREFERENCE($,'En_40_05_60','Outdoor fairgrounds',#606,$,$); -#611=IFCCLASSIFICATIONREFERENCE($,'En_40_05_68','Public amenities',#606,$,$); -#612=IFCCLASSIFICATIONREFERENCE($,'En_40_20','Dining entities',#605,$,$); -#613=IFCCLASSIFICATIONREFERENCE($,'En_40_20_23','Dining buildings',#612,$,$); -#614=IFCCLASSIFICATIONREFERENCE($,'En_40_35','Historic entities',#605,$,$); -#615=IFCCLASSIFICATIONREFERENCE($,'En_40_35_10','Buildings of historic interest',#614,$,$); -#616=IFCCLASSIFICATIONREFERENCE($,'En_40_35_36','Historic buildings',#614,$,$); -#617=IFCCLASSIFICATIONREFERENCE($,'En_40_60','Performing arts entities',#605,$,$); -#618=IFCCLASSIFICATIONREFERENCE($,'En_40_60_10','Multiple performing arts buildings',#617,$,$); -#619=IFCCLASSIFICATIONREFERENCE($,'En_40_60_70','Single performing arts buildings',#617,$,$); -#620=IFCCLASSIFICATIONREFERENCE($,'En_40_75','Social recreation entities',#605,$,$); -#621=IFCCLASSIFICATIONREFERENCE($,'En_40_75_10','Multiple social recreation buildings',#620,$,$); -#622=IFCCLASSIFICATIONREFERENCE($,'En_40_75_15','Club houses',#620,$,$); -#623=IFCCLASSIFICATIONREFERENCE($,'En_40_75_70','Single social recreation buildings',#620,$,$); -#624=IFCCLASSIFICATIONREFERENCE($,'En_40_75_94','Visitor centres',#620,$,$); -#625=IFCCLASSIFICATIONREFERENCE($,'En_42','Sport and activity entities',#382,$,$); -#626=IFCCLASSIFICATIONREFERENCE($,'En_42_15','Courts, pitches and field sports entities',#625,$,$); -#627=IFCCLASSIFICATIONREFERENCE($,'En_42_15_06','Ball courts',#626,$,$); -#628=IFCCLASSIFICATIONREFERENCE($,'En_42_15_81','Sports grounds',#626,$,$); -#629=IFCCLASSIFICATIONREFERENCE($,'En_42_15_82','Sports pitches',#626,$,$); -#630=IFCCLASSIFICATIONREFERENCE($,'En_42_40','Indoor activity entities',#625,$,$); -#631=IFCCLASSIFICATIONREFERENCE($,'En_42_40_80','Sports buildings',#630,$,$); -#632=IFCCLASSIFICATIONREFERENCE($,'En_42_55','Outdoor activity entities',#625,$,$); -#633=IFCCLASSIFICATIONREFERENCE($,'En_42_55_01','Activity grounds',#632,$,$); -#634=IFCCLASSIFICATIONREFERENCE($,'En_42_55_34','Golf driving ranges',#632,$,$); -#635=IFCCLASSIFICATIONREFERENCE($,'En_42_85','Swimming entities',#625,$,$); -#636=IFCCLASSIFICATIONREFERENCE($,'En_42_85_60','Outdoor swimming pools',#635,$,$); -#637=IFCCLASSIFICATIONREFERENCE($,'En_42_85_83','Swimming pool buildings',#635,$,$); -#638=IFCCLASSIFICATIONREFERENCE($,'En_42_90','Water activity entities',#625,$,$); -#639=IFCCLASSIFICATIONREFERENCE($,'En_42_95','Winter sports entities',#625,$,$); -#640=IFCCLASSIFICATIONREFERENCE($,'En_42_95_40','Ice rink buildings',#639,$,$); -#641=IFCCLASSIFICATIONREFERENCE($,'En_42_95_80','Ski resort buildings',#639,$,$); -#642=IFCCLASSIFICATIONREFERENCE($,'En_45','Residential entities',#382,$,$); -#643=IFCCLASSIFICATIONREFERENCE($,'En_45_10','Residential buildings',#642,$,$); -#644=IFCCLASSIFICATIONREFERENCE($,'En_45_10_39','Houses',#643,$,$); -#645=IFCCLASSIFICATIONREFERENCE($,'En_45_10_47','Long-term residential buildings',#643,$,$); -#646=IFCCLASSIFICATIONREFERENCE($,'En_45_10_70','Short term residential buildings',#643,$,$); -#647=IFCCLASSIFICATIONREFERENCE($,'En_45_10_90','Temporary residential buildings',#643,$,$); -#648=IFCCLASSIFICATIONREFERENCE($,'En_50','Waste disposal entities',#382,$,$); -#649=IFCCLASSIFICATIONREFERENCE($,'En_50_10','Gas waste collection entities',#648,$,$); -#650=IFCCLASSIFICATIONREFERENCE($,'En_50_20','Wet waste collection entities',#648,$,$); -#651=IFCCLASSIFICATIONREFERENCE($,'En_50_20_10','Wet waste collection tanks',#650,$,$); -#652=IFCCLASSIFICATIONREFERENCE($,'En_50_30','Drainage and wastewater collection',#648,$,$); -#653=IFCCLASSIFICATIONREFERENCE($,'En_50_30_25','Drainage collection pipelines',#652,$,$); -#654=IFCCLASSIFICATIONREFERENCE($,'En_50_30_85','Surface water collection pipelines',#652,$,$); -#655=IFCCLASSIFICATIONREFERENCE($,'En_50_30_98','Wastewater collection pipelines',#652,$,$); -#656=IFCCLASSIFICATIONREFERENCE($,'En_50_30_99','Wastewater collection structures',#652,$,$); -#657=IFCCLASSIFICATIONREFERENCE($,'En_50_40','Dry waste collection and distribution',#648,$,$); -#658=IFCCLASSIFICATIONREFERENCE($,'En_50_40_10','Dry waste collection structures',#657,$,$); -#659=IFCCLASSIFICATIONREFERENCE($,'En_50_40_50','Dry waste distribution structures',#657,$,$); -#660=IFCCLASSIFICATIONREFERENCE($,'En_50_50','Gas waste storage, treatment and disposal',#648,$,$); -#661=IFCCLASSIFICATIONREFERENCE($,'En_50_60','Wet waste storage, treatment and disposal',#648,$,$); -#662=IFCCLASSIFICATIONREFERENCE($,'En_50_70','Drainage storage, treatment and disposal',#648,$,$); -#663=IFCCLASSIFICATIONREFERENCE($,'En_50_75','Wastewater storage, treatment and disposal',#648,$,$); -#664=IFCCLASSIFICATIONREFERENCE($,'En_50_75_15','Wastewater entities',#663,$,$); -#665=IFCCLASSIFICATIONREFERENCE($,'En_50_75_40','Wastewater treatment buildings',#663,$,$); -#666=IFCCLASSIFICATIONREFERENCE($,'En_50_75_45','Wastewater treatment entities',#663,$,$); -#667=IFCCLASSIFICATIONREFERENCE($,'En_50_75_70','Wastewater disposal buildings',#663,$,$); -#668=IFCCLASSIFICATIONREFERENCE($,'En_50_80','Dry waste treatment and disposal',#648,$,$); -#669=IFCCLASSIFICATIONREFERENCE($,'En_50_80_40','Dry waste treatment structures',#668,$,$); -#670=IFCCLASSIFICATIONREFERENCE($,'En_50_80_70','Dry waste disposal structures',#668,$,$); -#671=IFCCLASSIFICATIONREFERENCE($,'En_55','Piped supply entities',#382,$,$); -#672=IFCCLASSIFICATIONREFERENCE($,'En_55_05','Gas extraction, treatment and storage',#671,$,$); -#673=IFCCLASSIFICATIONREFERENCE($,'En_55_05_30','Gas extraction structures',#672,$,$); -#674=IFCCLASSIFICATIONREFERENCE($,'En_55_05_35','Gas extraction vessels',#672,$,$); -#675=IFCCLASSIFICATIONREFERENCE($,'En_55_05_38','Gas extraction pipelines',#672,$,$); -#676=IFCCLASSIFICATIONREFERENCE($,'En_55_05_70','Gas treatment buildings',#672,$,$); -#677=IFCCLASSIFICATIONREFERENCE($,'En_55_05_75','Gas treatment plant',#672,$,$); -#678=IFCCLASSIFICATIONREFERENCE($,'En_55_05_78','Gas treatment pipelines',#672,$,$); -#679=IFCCLASSIFICATIONREFERENCE($,'En_55_10','Liquid fuel extraction and treatment entities',#671,$,$); -#680=IFCCLASSIFICATIONREFERENCE($,'En_55_10_10','Oil extraction structures',#679,$,$); -#681=IFCCLASSIFICATIONREFERENCE($,'En_55_10_50','Fuel treatment buildings',#679,$,$); -#682=IFCCLASSIFICATIONREFERENCE($,'En_55_10_55','Fuel treatment tanks',#679,$,$); -#683=IFCCLASSIFICATIONREFERENCE($,'En_55_10_58','Fuel treatment pipelines',#679,$,$); -#684=IFCCLASSIFICATIONREFERENCE($,'En_55_15','Water extraction and treatment entities',#671,$,$); -#685=IFCCLASSIFICATIONREFERENCE($,'En_55_15_10','Water extraction buildings',#684,$,$); -#686=IFCCLASSIFICATIONREFERENCE($,'En_55_15_15','Water extraction tanks',#684,$,$); -#687=IFCCLASSIFICATIONREFERENCE($,'En_55_15_20','Water extraction pipelines',#684,$,$); -#688=IFCCLASSIFICATIONREFERENCE($,'En_55_15_50','Water treatment buildings',#684,$,$); -#689=IFCCLASSIFICATIONREFERENCE($,'En_55_15_55','Water treatment tanks',#684,$,$); -#690=IFCCLASSIFICATIONREFERENCE($,'En_55_20','Gas supply entities',#671,$,$); -#691=IFCCLASSIFICATIONREFERENCE($,'En_55_20_50','Gas distribution structures',#690,$,$); -#692=IFCCLASSIFICATIONREFERENCE($,'En_55_20_60','Gas distribution pipelines',#690,$,$); -#693=IFCCLASSIFICATIONREFERENCE($,'En_55_30','Fire extinguishing supply entities',#671,$,$); -#694=IFCCLASSIFICATIONREFERENCE($,'En_55_40','Steam supply entities',#671,$,$); -#695=IFCCLASSIFICATIONREFERENCE($,'En_55_50','Liquid fuel supply entities',#671,$,$); -#696=IFCCLASSIFICATIONREFERENCE($,'En_55_50_20','Fuel distribution pipelines',#695,$,$); -#697=IFCCLASSIFICATIONREFERENCE($,'En_55_50_45','Liquid fuel distribution buildings',#695,$,$); -#698=IFCCLASSIFICATIONREFERENCE($,'En_55_60','Process liquid supply entities',#671,$,$); -#699=IFCCLASSIFICATIONREFERENCE($,'En_55_70','Water supply entities',#671,$,$); -#700=IFCCLASSIFICATIONREFERENCE($,'En_55_70_10','Water distribution buildings',#699,$,$); -#701=IFCCLASSIFICATIONREFERENCE($,'En_55_70_18','Water distribution pipelines',#699,$,$); -#702=IFCCLASSIFICATIONREFERENCE($,'En_55_90','Piped solids supply entities',#671,$,$); -#703=IFCCLASSIFICATIONREFERENCE($,'En_60','Heating, cooling and refrigeration entities',#382,$,$); -#704=IFCCLASSIFICATIONREFERENCE($,'En_60_30','Rail and paving heating entities',#703,$,$); -#705=IFCCLASSIFICATIONREFERENCE($,'En_60_40','Space heating and cooling entities',#703,$,$); -#706=IFCCLASSIFICATIONREFERENCE($,'En_60_40_10','District heating buildings',#705,$,$); -#707=IFCCLASSIFICATIONREFERENCE($,'En_60_40_20','District heating pipelines',#705,$,$); -#708=IFCCLASSIFICATIONREFERENCE($,'En_60_40_50','District cooling buildings',#705,$,$); -#709=IFCCLASSIFICATIONREFERENCE($,'En_60_40_60','District cooling pipelines',#705,$,$); -#710=IFCCLASSIFICATIONREFERENCE($,'En_60_60','Refrigeration entities',#703,$,$); -#711=IFCCLASSIFICATIONREFERENCE($,'En_60_80','Drying entities',#703,$,$); -#712=IFCCLASSIFICATIONREFERENCE($,'En_65','Ventilation and air conditioning entities',#382,$,$); -#713=IFCCLASSIFICATIONREFERENCE($,'En_65_40','Ventilation entities',#712,$,$); -#714=IFCCLASSIFICATIONREFERENCE($,'En_65_40_80','Shaft and tunnel ventilation plant building',#713,$,$); -#715=IFCCLASSIFICATIONREFERENCE($,'En_65_80','Air conditioning entities',#712,$,$); -#716=IFCCLASSIFICATIONREFERENCE($,'En_70','Electrical power generation and distribution entities',#382,$,$); -#717=IFCCLASSIFICATIONREFERENCE($,'En_70_10','Electrical power generation entities',#716,$,$); -#718=IFCCLASSIFICATIONREFERENCE($,'En_70_10_10','Electrical power generation buildings',#717,$,$); -#719=IFCCLASSIFICATIONREFERENCE($,'En_70_10_80','Solar panel fields',#717,$,$); -#720=IFCCLASSIFICATIONREFERENCE($,'En_70_10_90','Wind turbines',#717,$,$); -#721=IFCCLASSIFICATIONREFERENCE($,'En_70_30','Electricity distribution and transmission entities',#716,$,$); -#722=IFCCLASSIFICATIONREFERENCE($,'En_70_30_18','Electricity transmission pylons and lines',#721,$,$); -#723=IFCCLASSIFICATIONREFERENCE($,'En_70_30_35','High-voltage electricity substations',#721,$,$); -#724=IFCCLASSIFICATIONREFERENCE($,'En_70_30_45','Low-voltage electricity substations',#721,$,$); -#725=IFCCLASSIFICATIONREFERENCE($,'En_70_30_90','Underground electricity transmission lines',#721,$,$); -#726=IFCCLASSIFICATIONREFERENCE($,'En_75','Communications, security, safety and protection entities',#382,$,$); -#727=IFCCLASSIFICATIONREFERENCE($,'En_75_10','Communication entities',#726,$,$); -#728=IFCCLASSIFICATIONREFERENCE($,'En_75_10_10','Broadcast communications buildings',#727,$,$); -#729=IFCCLASSIFICATIONREFERENCE($,'En_75_10_16','Broadcast communications masts and towers',#727,$,$); -#730=IFCCLASSIFICATIONREFERENCE($,'En_75_10_20','Data centres',#727,$,$); -#731=IFCCLASSIFICATIONREFERENCE($,'En_75_30','Signalling entities',#726,$,$); -#732=IFCCLASSIFICATIONREFERENCE($,'En_75_30_10','Peer-to-peer communications buildings',#731,$,$); -#733=IFCCLASSIFICATIONREFERENCE($,'En_75_30_18','Peer-to-peer communications networks',#731,$,$); -#734=IFCCLASSIFICATIONREFERENCE($,'En_75_30_78','Signalling control centres',#731,$,$); -#735=IFCCLASSIFICATIONREFERENCE($,'En_75_40','Security systems entities',#726,$,$); -#736=IFCCLASSIFICATIONREFERENCE($,'En_75_50','Safety and protection entities',#726,$,$); -#737=IFCCLASSIFICATIONREFERENCE($,'En_75_60','Environmental safety entities',#726,$,$); -#738=IFCCLASSIFICATIONREFERENCE($,'En_75_70','Control and management entities',#726,$,$); -#739=IFCCLASSIFICATIONREFERENCE($,'En_75_70_60','Operational control centres',#738,$,$); -#740=IFCCLASSIFICATIONREFERENCE($,'En_75_80','Protection entities',#726,$,$); -#741=IFCCLASSIFICATIONREFERENCE($,'En_80','Transport entities',#382,$,$); -#742=IFCCLASSIFICATIONREFERENCE($,'En_80_05','Aerospace entities',#741,$,$); -#743=IFCCLASSIFICATIONREFERENCE($,'En_80_05_01','Air traffic control towers',#742,$,$); -#744=IFCCLASSIFICATIONREFERENCE($,'En_80_05_02','Aircraft hangars',#742,$,$); -#745=IFCCLASSIFICATIONREFERENCE($,'En_80_05_60','Passenger terminal buildings',#742,$,$); -#746=IFCCLASSIFICATIONREFERENCE($,'En_80_20','Cable transport entities',#741,$,$); -#747=IFCCLASSIFICATIONREFERENCE($,'En_80_20_11','Cable car entities',#746,$,$); -#748=IFCCLASSIFICATIONREFERENCE($,'En_80_20_12','Cable car stations',#746,$,$); -#749=IFCCLASSIFICATIONREFERENCE($,'En_80_20_86','Suspended cableways',#746,$,$); -#750=IFCCLASSIFICATIONREFERENCE($,'En_80_35','Road entities',#741,$,$); -#751=IFCCLASSIFICATIONREFERENCE($,'En_80_35_01','Access roads',#750,$,$); -#752=IFCCLASSIFICATIONREFERENCE($,'En_80_35_05','Bus lanes',#750,$,$); -#753=IFCCLASSIFICATIONREFERENCE($,'En_80_35_07','Bus maintenance depots',#750,$,$); -#754=IFCCLASSIFICATIONREFERENCE($,'En_80_35_09','Bus and coach stations',#750,$,$); -#755=IFCCLASSIFICATIONREFERENCE($,'En_80_35_34','Guided bus lanes',#750,$,$); -#756=IFCCLASSIFICATIONREFERENCE($,'En_80_35_35','Highway maintenance depots',#750,$,$); -#757=IFCCLASSIFICATIONREFERENCE($,'En_80_35_38','Highway service stations',#750,$,$); -#758=IFCCLASSIFICATIONREFERENCE($,'En_80_35_56','Motorways',#750,$,$); -#759=IFCCLASSIFICATIONREFERENCE($,'En_80_35_67','Private roads',#750,$,$); -#760=IFCCLASSIFICATIONREFERENCE($,'En_80_35_74','Roads',#750,$,$); -#761=IFCCLASSIFICATIONREFERENCE($,'En_80_35_77','Service area buildings',#750,$,$); -#762=IFCCLASSIFICATIONREFERENCE($,'En_80_35_88','Tollgates',#750,$,$); -#763=IFCCLASSIFICATIONREFERENCE($,'En_80_35_89','Tracks',#750,$,$); -#764=IFCCLASSIFICATIONREFERENCE($,'En_80_35_90','Truck maintenance depots',#750,$,$); -#765=IFCCLASSIFICATIONREFERENCE($,'En_80_40','Pathways',#741,$,$); -#766=IFCCLASSIFICATIONREFERENCE($,'En_80_40_08','Bridleways',#765,$,$); -#767=IFCCLASSIFICATIONREFERENCE($,'En_80_40_10','Byways',#765,$,$); -#768=IFCCLASSIFICATIONREFERENCE($,'En_80_40_20','Cycle pathways',#765,$,$); -#769=IFCCLASSIFICATIONREFERENCE($,'En_80_40_30','Footpaths',#765,$,$); -#770=IFCCLASSIFICATIONREFERENCE($,'En_80_40_37','Hiking paths',#765,$,$); -#771=IFCCLASSIFICATIONREFERENCE($,'En_80_40_66','Promenades',#765,$,$); -#772=IFCCLASSIFICATIONREFERENCE($,'En_80_40_70','Rambler ways',#765,$,$); -#773=IFCCLASSIFICATIONREFERENCE($,'En_80_40_90','Trails',#765,$,$); -#774=IFCCLASSIFICATIONREFERENCE($,'En_80_45','Vehicle storage entities',#741,$,$); -#775=IFCCLASSIFICATIONREFERENCE($,'En_80_45_08','Bus parks',#774,$,$); -#776=IFCCLASSIFICATIONREFERENCE($,'En_80_45_11','Car garaging entities',#774,$,$); -#777=IFCCLASSIFICATIONREFERENCE($,'En_80_45_17','Coach parks',#774,$,$); -#778=IFCCLASSIFICATIONREFERENCE($,'En_80_45_55','Multi-storey vehicle parks',#774,$,$); -#779=IFCCLASSIFICATIONREFERENCE($,'En_80_45_85','Surface vehicle parks',#774,$,$); -#780=IFCCLASSIFICATIONREFERENCE($,'En_80_45_89','Truck parks',#774,$,$); -#781=IFCCLASSIFICATIONREFERENCE($,'En_80_45_92','Underground vehicle parks',#774,$,$); -#782=IFCCLASSIFICATIONREFERENCE($,'En_80_50','Railway entities',#741,$,$); -#783=IFCCLASSIFICATIONREFERENCE($,'En_80_50_53','Monorail entities',#782,$,$); -#784=IFCCLASSIFICATIONREFERENCE($,'En_80_50_58','Platforms',#782,$,$); -#785=IFCCLASSIFICATIONREFERENCE($,'En_80_50_60','Rack rail maintenance buildings',#782,$,$); -#786=IFCCLASSIFICATIONREFERENCE($,'En_80_50_62','Rack railways track entities',#782,$,$); -#787=IFCCLASSIFICATIONREFERENCE($,'En_80_50_64','Rail distribution depots',#782,$,$); -#788=IFCCLASSIFICATIONREFERENCE($,'En_80_50_68','Rail marshalling entities',#782,$,$); -#789=IFCCLASSIFICATIONREFERENCE($,'En_80_50_71','Railway corridors',#782,$,$); -#790=IFCCLASSIFICATIONREFERENCE($,'En_80_50_74','Railway stations',#782,$,$); -#791=IFCCLASSIFICATIONREFERENCE($,'En_80_50_76','Railway sidings',#782,$,$); -#792=IFCCLASSIFICATIONREFERENCE($,'En_80_50_78','Rolling stock depots',#782,$,$); -#793=IFCCLASSIFICATIONREFERENCE($,'En_80_50_83','Station buildings',#782,$,$); -#794=IFCCLASSIFICATIONREFERENCE($,'En_80_50_86','Track maintenance depots',#782,$,$); -#795=IFCCLASSIFICATIONREFERENCE($,'En_80_50_87','Trackside circuit breaker equipment buildings',#782,$,$); -#796=IFCCLASSIFICATIONREFERENCE($,'En_80_50_88','Train maintenance depots',#782,$,$); -#797=IFCCLASSIFICATIONREFERENCE($,'En_80_50_90','Tramways',#782,$,$); -#798=IFCCLASSIFICATIONREFERENCE($,'En_80_50_94','Underground railway stations',#782,$,$); -#799=IFCCLASSIFICATIONREFERENCE($,'En_80_50_95','Wagon decontamination buildings',#782,$,$); -#800=IFCCLASSIFICATIONREFERENCE($,'En_80_50_97','Wagon maintenance buildings',#782,$,$); -#801=IFCCLASSIFICATIONREFERENCE($,'En_80_70','Marine and waterways transport entities',#741,$,$); -#802=IFCCLASSIFICATIONREFERENCE($,'En_80_70_06','Barge loading terminals',#801,$,$); -#803=IFCCLASSIFICATIONREFERENCE($,'En_80_70_11','Canal channels',#801,$,$); -#804=IFCCLASSIFICATIONREFERENCE($,'En_80_70_15','Canal locks',#801,$,$); -#805=IFCCLASSIFICATIONREFERENCE($,'En_80_70_46','Lake passenger terminals',#801,$,$); -#806=IFCCLASSIFICATIONREFERENCE($,'En_80_70_50','Marinas',#801,$,$); -#807=IFCCLASSIFICATIONREFERENCE($,'En_80_70_71','River passenger terminals',#801,$,$); -#808=IFCCLASSIFICATIONREFERENCE($,'En_80_90','Transport hub entities',#741,$,$); -#809=IFCCLASSIFICATIONREFERENCE($,'En_80_90_30','Freight depots',#808,$,$); -#810=IFCCLASSIFICATIONREFERENCE($,'En_80_90_66','Rail freight entities',#808,$,$); -#811=IFCCLASSIFICATIONREFERENCE($,'En_80_90_73','Road freight depots',#808,$,$); -#812=IFCCLASSIFICATIONREFERENCE($,'En_80_90_90','Transport interchanges',#808,$,$); -#813=IFCCLASSIFICATIONREFERENCE($,'En_80_94','Bridges',#741,$,$); -#814=IFCCLASSIFICATIONREFERENCE($,'En_80_94_30','Fixed bridges',#813,$,$); -#815=IFCCLASSIFICATIONREFERENCE($,'En_80_94_50','Moveable bridges',#813,$,$); -#816=IFCCLASSIFICATIONREFERENCE($,'En_80_96','Tunnels and shafts',#741,$,$); -#817=IFCCLASSIFICATIONREFERENCE($,'En_80_96_20','Drift tunnels',#816,$,$); -#818=IFCCLASSIFICATIONREFERENCE($,'En_80_96_46','Lined drift tunnels',#816,$,$); -#819=IFCCLASSIFICATIONREFERENCE($,'En_80_96_49','Lined tunnels',#816,$,$); -#820=IFCCLASSIFICATIONREFERENCE($,'En_80_96_80','Shafts',#816,$,$); -#821=IFCCLASSIFICATIONREFERENCE($,'En_80_96_90','Tunnels',#816,$,$); -#822=IFCCLASSIFICATIONREFERENCE($,'En_80_96_91','Tunnel portals',#816,$,$); -#823=IFCCLASSIFICATIONREFERENCE($,'En_80_96_92','Underpasses',#816,$,$); -#824=IFCCLASSIFICATIONREFERENCE($,'En_90','Circulation and storage entities',#382,$,$); -#825=IFCCLASSIFICATIONREFERENCE($,'En_90_10','Circulation entities',#824,$,$); -#826=IFCCLASSIFICATIONREFERENCE($,'En_90_10_02','Access stairways and walkways',#825,$,$); -#827=IFCCLASSIFICATIONREFERENCE($,'En_90_10_62','Pedestrianized areas',#825,$,$); -#828=IFCCLASSIFICATIONREFERENCE($,'En_90_10_77','External service areas',#825,$,$); -#829=IFCCLASSIFICATIONREFERENCE($,'En_90_50','Storage entities',#824,$,$); -#830=IFCCLASSIFICATIONREFERENCE($,'En_90_50_02','Agricultural storage buildings',#829,$,$); -#831=IFCCLASSIFICATIONREFERENCE($,'En_90_50_03','Agricultural storage silos',#829,$,$); -#832=IFCCLASSIFICATIONREFERENCE($,'En_90_50_10','Dry waste storage structures',#829,$,$); -#833=IFCCLASSIFICATIONREFERENCE($,'En_90_50_11','Dry waste storage yards',#829,$,$); -#834=IFCCLASSIFICATIONREFERENCE($,'En_90_50_28','Explosives stores',#829,$,$); -#835=IFCCLASSIFICATIONREFERENCE($,'En_90_50_50','Manufacturing tanks and silos',#829,$,$); -#836=IFCCLASSIFICATIONREFERENCE($,'En_90_50_53','Mineral storage silos',#829,$,$); -#837=IFCCLASSIFICATIONREFERENCE($,'En_90_50_55','Motor vehicle storage entities',#829,$,$); -#838=IFCCLASSIFICATIONREFERENCE($,'En_90_50_58','Oil and gas storage tanks',#829,$,$); -#839=IFCCLASSIFICATIONREFERENCE($,'En_90_50_68','Refrigerated container storage entities',#829,$,$); -#840=IFCCLASSIFICATIONREFERENCE($,'En_90_50_70','Storage buildings',#829,$,$); -#841=IFCCLASSIFICATIONREFERENCE($,'En_90_50_96','Wastewater storage structures',#829,$,$); -#842=IFCCLASSIFICATIONREFERENCE($,'En_90_90','Plant and control entities',#824,$,$); -#843=IFCCLASSIFICATIONREFERENCE($,'En_90_90_09','Buried services routes',#842,$,$); -#844=IFCCLASSIFICATIONREFERENCE($,'En_90_90_11','Cable routes',#842,$,$); -#845=IFCCLASSIFICATIONREFERENCE($,'En_90_90_33','Gauge houses',#842,$,$); -#846=IFCCLASSIFICATIONREFERENCE($,'En_90_90_35','Gauging station buildings',#842,$,$); -#847=IFCCLASSIFICATIONREFERENCE($,'En_90_90_50','Mechanical services buildings',#842,$,$); -#848=IFCCLASSIFICATIONREFERENCE($,'En_90_90_64','Plant and equipment buildings',#842,$,$); -#849=IFCCLASSIFICATIONREFERENCE($,'En_90_90_68','Pump houses',#842,$,$); -#850=IFCCLASSIFICATIONREFERENCE($,'Ac','Activities',#1,$,$); -#851=IFCCLASSIFICATIONREFERENCE($,'Ac_05','Project management activities',#850,$,$); -#852=IFCCLASSIFICATIONREFERENCE($,'Ac_05_00','Strategy stage activities',#851,$,$); -#853=IFCCLASSIFICATIONREFERENCE($,'Ac_05_00_10','Business case development',#852,$,$); -#854=IFCCLASSIFICATIONREFERENCE($,'Ac_05_00_80','Strategic brief preparation',#852,$,$); -#855=IFCCLASSIFICATIONREFERENCE($,'Ac_05_00_82','Strategic brief submission',#852,$,$); -#856=IFCCLASSIFICATIONREFERENCE($,'Ac_05_10','Brief stage activities',#851,$,$); -#857=IFCCLASSIFICATIONREFERENCE($,'Ac_05_10_15','Cost estimate preparation',#856,$,$); -#858=IFCCLASSIFICATIONREFERENCE($,'Ac_05_10_17','Cost estimate submission',#856,$,$); -#859=IFCCLASSIFICATIONREFERENCE($,'Ac_05_10_29','Feasibility study preparation',#856,$,$); -#860=IFCCLASSIFICATIONREFERENCE($,'Ac_05_10_31','Feasibility study submission',#856,$,$); -#861=IFCCLASSIFICATIONREFERENCE($,'Ac_05_10_61','Preliminary design preparation',#856,$,$); -#862=IFCCLASSIFICATIONREFERENCE($,'Ac_05_10_63','Preliminary design submission',#856,$,$); -#863=IFCCLASSIFICATIONREFERENCE($,'Ac_05_10_65','Project brief and objectives preparation',#856,$,$); -#864=IFCCLASSIFICATIONREFERENCE($,'Ac_05_10_67','Project brief and objectives submission',#856,$,$); -#865=IFCCLASSIFICATIONREFERENCE($,'Ac_05_20','Concept stage activities',#851,$,$); -#866=IFCCLASSIFICATIONREFERENCE($,'Ac_05_20_15','Concept cost report preparation',#865,$,$); -#867=IFCCLASSIFICATIONREFERENCE($,'Ac_05_20_17','Concept cost report submission',#865,$,$); -#868=IFCCLASSIFICATIONREFERENCE($,'Ac_05_20_21','Concept design development',#865,$,$); -#869=IFCCLASSIFICATIONREFERENCE($,'Ac_05_20_23','Concept design report preparation',#865,$,$); -#870=IFCCLASSIFICATIONREFERENCE($,'Ac_05_20_25','Concept design report submission',#865,$,$); -#871=IFCCLASSIFICATIONREFERENCE($,'Ac_05_30','Definition stage activities',#851,$,$); -#872=IFCCLASSIFICATIONREFERENCE($,'Ac_05_30_03','Agreement negotiating',#871,$,$); -#873=IFCCLASSIFICATIONREFERENCE($,'Ac_05_30_10','Building regulation assessing',#871,$,$); -#874=IFCCLASSIFICATIONREFERENCE($,'Ac_05_30_21','Definition design cost report preparation',#871,$,$); -#875=IFCCLASSIFICATIONREFERENCE($,'Ac_05_30_23','Definition design cost report submission',#871,$,$); -#876=IFCCLASSIFICATIONREFERENCE($,'Ac_05_30_25','Definition design development',#871,$,$); -#877=IFCCLASSIFICATIONREFERENCE($,'Ac_05_30_27','Definition design report preparation',#871,$,$); -#878=IFCCLASSIFICATIONREFERENCE($,'Ac_05_30_28','Definition design submission',#871,$,$); -#879=IFCCLASSIFICATIONREFERENCE($,'Ac_05_30_29','Drainage adoption agreeing',#871,$,$); -#880=IFCCLASSIFICATIONREFERENCE($,'Ac_05_30_37','Highways adoption agreeing',#871,$,$); -#881=IFCCLASSIFICATIONREFERENCE($,'Ac_05_30_60','Party wall notices agreeing',#871,$,$); -#882=IFCCLASSIFICATIONREFERENCE($,'Ac_05_30_64','Planning preparation',#871,$,$); -#883=IFCCLASSIFICATIONREFERENCE($,'Ac_05_30_85','Sustainability assessing',#871,$,$); -#884=IFCCLASSIFICATIONREFERENCE($,'Ac_05_40','Design stage activities',#851,$,$); -#885=IFCCLASSIFICATIONREFERENCE($,'Ac_05_40_60','Prototype requesting',#884,$,$); -#886=IFCCLASSIFICATIONREFERENCE($,'Ac_05_40_70','Sample requesting',#884,$,$); -#887=IFCCLASSIFICATIONREFERENCE($,'Ac_05_40_85','Technical design cost report preparation',#884,$,$); -#888=IFCCLASSIFICATIONREFERENCE($,'Ac_05_40_87','Technical design development',#884,$,$); -#889=IFCCLASSIFICATIONREFERENCE($,'Ac_05_40_89','Technical design report preparation',#884,$,$); -#890=IFCCLASSIFICATIONREFERENCE($,'Ac_05_40_91','Technical design submission',#884,$,$); -#891=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50','Build and commission stage activities',#851,$,$); -#892=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_15','Contractor mobilizing',#891,$,$); -#893=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_41','Information submitting',#891,$,$); -#894=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_43','Inspecting',#891,$,$); -#895=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_51','Measuring',#891,$,$); -#896=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_54','Monitoring',#891,$,$); -#897=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_60','Prototype submission',#891,$,$); -#898=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_70','Sample submission',#891,$,$); -#899=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_72','Setting out',#891,$,$); -#900=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_75','Starting on site',#891,$,$); -#901=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_85','Tender analyzing',#891,$,$); -#902=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_87','Tender negotiating',#891,$,$); -#903=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_89','Tender recommendation reporting',#891,$,$); -#904=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_91','Timber sourcing',#891,$,$); -#905=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_97','Works commencing',#891,$,$); -#906=IFCCLASSIFICATIONREFERENCE($,'Ac_05_60','Handover and close-out stage activities',#851,$,$); -#907=IFCCLASSIFICATIONREFERENCE($,'Ac_05_60_10','Building contract administrating',#906,$,$); -#908=IFCCLASSIFICATIONREFERENCE($,'Ac_05_60_15','Completing',#906,$,$); -#909=IFCCLASSIFICATIONREFERENCE($,'Ac_05_60_30','Final clean',#906,$,$); -#910=IFCCLASSIFICATIONREFERENCE($,'Ac_05_60_35','Handing over',#906,$,$); -#911=IFCCLASSIFICATIONREFERENCE($,'Ac_05_60_60','Partial handing over',#906,$,$); -#912=IFCCLASSIFICATIONREFERENCE($,'Ac_05_60_70','Rectifying non-compliant items',#906,$,$); -#913=IFCCLASSIFICATIONREFERENCE($,'Ac_05_60_80','Sectional completing',#906,$,$); -#914=IFCCLASSIFICATIONREFERENCE($,'Ac_05_70','Operation and end of life stage activities',#851,$,$); -#915=IFCCLASSIFICATIONREFERENCE($,'Ac_05_70_10','Building user assisting',#914,$,$); -#916=IFCCLASSIFICATIONREFERENCE($,'Ac_05_70_48','Logistics',#914,$,$); -#917=IFCCLASSIFICATIONREFERENCE($,'Ac_10','Preparation, construction and repair',#850,$,$); -#918=IFCCLASSIFICATIONREFERENCE($,'Ac_10_10','Deconstruction and demolition',#917,$,$); -#919=IFCCLASSIFICATIONREFERENCE($,'Ac_10_10_20','Deconstruction',#918,$,$); -#920=IFCCLASSIFICATIONREFERENCE($,'Ac_10_10_25','Demolition',#918,$,$); -#921=IFCCLASSIFICATIONREFERENCE($,'Ac_10_20','Decontamination',#917,$,$); -#922=IFCCLASSIFICATIONREFERENCE($,'Ac_10_30','Site clearance',#917,$,$); -#923=IFCCLASSIFICATIONREFERENCE($,'Ac_10_30_10','Bush and scrub removal',#922,$,$); -#924=IFCCLASSIFICATIONREFERENCE($,'Ac_10_30_15','Constructed material clearance',#922,$,$); -#925=IFCCLASSIFICATIONREFERENCE($,'Ac_10_30_80','Soil removal',#922,$,$); -#926=IFCCLASSIFICATIONREFERENCE($,'Ac_10_30_90','Tree removal',#922,$,$); -#927=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40','Construction',#917,$,$); -#928=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40_08','Bricklaying',#927,$,$); -#929=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40_11','Carpentry and joinery',#927,$,$); -#930=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40_13','Carpet laying',#927,$,$); -#931=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40_22','Diamond drilling',#927,$,$); -#932=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40_25','Ductwork installing',#927,$,$); -#933=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40_27','Electrical system installing',#927,$,$); -#934=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40_30','Formwork installing',#927,$,$); -#935=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40_41','Internal fitting out',#927,$,$); -#936=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40_60','Painting and decorating',#927,$,$); -#937=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40_63','Pipe fitting',#927,$,$); -#938=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40_65','Plastering and rendering',#927,$,$); -#939=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40_67','Plumbing',#927,$,$); -#940=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40_88','Tiling',#927,$,$); -#941=IFCCLASSIFICATIONREFERENCE($,'Ac_10_60','Protection activities',#917,$,$); -#942=IFCCLASSIFICATIONREFERENCE($,'Ac_10_60_90','Tree protecting',#941,$,$); -#943=IFCCLASSIFICATIONREFERENCE($,'Ac_10_70','Remediation, repair and renovation',#917,$,$); -#944=IFCCLASSIFICATIONREFERENCE($,'Ac_10_70_65','Remediation',#943,$,$); -#945=IFCCLASSIFICATIONREFERENCE($,'Ac_10_70_70','Renovation',#943,$,$); -#946=IFCCLASSIFICATIONREFERENCE($,'Ac_10_70_75','Repair',#943,$,$); -#947=IFCCLASSIFICATIONREFERENCE($,'Ac_10_80','Structure moving',#917,$,$); -#948=IFCCLASSIFICATIONREFERENCE($,'Ac_15','Survey activities',#850,$,$); -#949=IFCCLASSIFICATIONREFERENCE($,'Ac_15_05','Aquatic surveying',#948,$,$); -#950=IFCCLASSIFICATIONREFERENCE($,'Ac_15_05_11','Canals surveying',#949,$,$); -#951=IFCCLASSIFICATIONREFERENCE($,'Ac_15_05_15','Coastal surveying',#949,$,$); -#952=IFCCLASSIFICATIONREFERENCE($,'Ac_15_05_36','Hydrological surveying',#949,$,$); -#953=IFCCLASSIFICATIONREFERENCE($,'Ac_15_05_46','Lakes and ponds surveying',#949,$,$); -#954=IFCCLASSIFICATIONREFERENCE($,'Ac_15_05_70','Reservoirs surveying',#949,$,$); -#955=IFCCLASSIFICATIONREFERENCE($,'Ac_15_05_72','Rivers and streams surveying',#949,$,$); -#956=IFCCLASSIFICATIONREFERENCE($,'Ac_15_05_73','River estuary surveying',#949,$,$); -#957=IFCCLASSIFICATIONREFERENCE($,'Ac_15_10','Surveying methods',#948,$,$); -#958=IFCCLASSIFICATIONREFERENCE($,'Ac_15_10_01','Acoustic surveying',#957,$,$); -#959=IFCCLASSIFICATIONREFERENCE($,'Ac_15_10_03','Aerial surveying',#957,$,$); -#960=IFCCLASSIFICATIONREFERENCE($,'Ac_15_10_10','Borehole surveying',#957,$,$); -#961=IFCCLASSIFICATIONREFERENCE($,'Ac_15_10_14','Closed-circuit television surveying',#957,$,$); -#962=IFCCLASSIFICATIONREFERENCE($,'Ac_15_10_22','Desk top studying',#957,$,$); -#963=IFCCLASSIFICATIONREFERENCE($,'Ac_15_10_32','Geophysical surveying',#957,$,$); -#964=IFCCLASSIFICATIONREFERENCE($,'Ac_15_10_34','Ground penetrating radar surveying',#957,$,$); -#965=IFCCLASSIFICATIONREFERENCE($,'Ac_15_10_70','Radio frequency location surveying',#957,$,$); -#966=IFCCLASSIFICATIONREFERENCE($,'Ac_15_10_80','Satellite surveying',#957,$,$); -#967=IFCCLASSIFICATIONREFERENCE($,'Ac_15_10_90','Trial holes surveying',#957,$,$); -#968=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15','Building services condition surveying',#948,$,$); -#969=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15_06','Below ground services surveying',#968,$,$); -#970=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15_08','Boilers, heating and hot water systems surveying',#968,$,$); -#971=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15_11','Catering equipment surveying',#968,$,$); -#972=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15_15','Cold water and water treatment systems surveying',#968,$,$); -#973=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15_16','Control systems surveying',#968,$,$); -#974=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15_28','Escalator and moving pavement systems surveying',#968,$,$); -#975=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15_30','Fire alarm systems surveying',#968,$,$); -#976=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15_34','Generators system surveying',#968,$,$); -#977=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15_47','Lift installation surveying',#968,$,$); -#978=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15_48','Low voltage general power electrical installations surveying',#968,$,$); -#979=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15_71','Refrigeration systems surveying',#968,$,$); -#980=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15_82','Sprinkler systems surveying',#968,$,$); -#981=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15_95','Ventilation and air conditioning systems surveying',#968,$,$); -#982=IFCCLASSIFICATIONREFERENCE($,'Ac_15_20','Ecological and environmental surveying',#948,$,$); -#983=IFCCLASSIFICATIONREFERENCE($,'Ac_15_20_03','Animal conservation assessment surveying',#982,$,$); -#984=IFCCLASSIFICATIONREFERENCE($,'Ac_15_20_05','Arboricultural surveying',#982,$,$); -#985=IFCCLASSIFICATIONREFERENCE($,'Ac_15_20_08','Bird and pest surveying',#982,$,$); -#986=IFCCLASSIFICATIONREFERENCE($,'Ac_15_20_25','Ecological building surveying',#982,$,$); -#987=IFCCLASSIFICATIONREFERENCE($,'Ac_15_20_27','Ecological site surveying',#982,$,$); -#988=IFCCLASSIFICATIONREFERENCE($,'Ac_15_20_28','Environmental impact assessment surveying',#982,$,$); -#989=IFCCLASSIFICATIONREFERENCE($,'Ac_15_20_40','Invasive species surveying',#982,$,$); -#990=IFCCLASSIFICATIONREFERENCE($,'Ac_15_20_46','Landscape character assessing',#982,$,$); -#991=IFCCLASSIFICATIONREFERENCE($,'Ac_15_20_48','Landscape visual assessing',#982,$,$); -#992=IFCCLASSIFICATIONREFERENCE($,'Ac_15_20_56','Nuisance animal species surveying',#982,$,$); -#993=IFCCLASSIFICATIONREFERENCE($,'Ac_15_20_58','Ornithological surveying',#982,$,$); -#994=IFCCLASSIFICATIONREFERENCE($,'Ac_15_20_85','Strategic environmental assessing',#982,$,$); -#995=IFCCLASSIFICATIONREFERENCE($,'Ac_15_30','Geometric surveying',#948,$,$); -#996=IFCCLASSIFICATIONREFERENCE($,'Ac_15_30_50','Measured and metric surveying',#995,$,$); -#997=IFCCLASSIFICATIONREFERENCE($,'Ac_15_30_90','Topographical surveying',#995,$,$); -#998=IFCCLASSIFICATIONREFERENCE($,'Ac_15_40','Hazardous material surveying',#948,$,$); -#999=IFCCLASSIFICATIONREFERENCE($,'Ac_15_40_05','Asbestos surveying',#998,$,$); -#1000=IFCCLASSIFICATIONREFERENCE($,'Ac_15_40_45','Lead paint surveying',#998,$,$); -#1001=IFCCLASSIFICATIONREFERENCE($,'Ac_15_40_70','Radon and hazardous ground gases surveying',#998,$,$); -#1002=IFCCLASSIFICATIONREFERENCE($,'Ac_15_45','Historic building and site surveying',#948,$,$); -#1003=IFCCLASSIFICATIONREFERENCE($,'Ac_15_45_35','Historic building surveying',#1002,$,$); -#1004=IFCCLASSIFICATIONREFERENCE($,'Ac_15_45_37','Historic site surveying',#1002,$,$); -#1005=IFCCLASSIFICATIONREFERENCE($,'Ac_15_50','Building fabric surveying',#948,$,$); -#1006=IFCCLASSIFICATIONREFERENCE($,'Ac_15_50_10','Building surveying',#1005,$,$); -#1007=IFCCLASSIFICATIONREFERENCE($,'Ac_15_50_15','Concealed elements surveying',#1005,$,$); -#1008=IFCCLASSIFICATIONREFERENCE($,'Ac_15_50_17','Concrete cover surveying',#1005,$,$); -#1009=IFCCLASSIFICATIONREFERENCE($,'Ac_15_50_20','Damp ingress and excess moisture surveying',#1005,$,$); -#1010=IFCCLASSIFICATIONREFERENCE($,'Ac_15_50_22','Dilapidations surveying',#1005,$,$); -#1011=IFCCLASSIFICATIONREFERENCE($,'Ac_15_50_25','Doors, windows and glazing surveying',#1005,$,$); -#1012=IFCCLASSIFICATIONREFERENCE($,'Ac_15_50_50','Masonry surveying',#1005,$,$); -#1013=IFCCLASSIFICATIONREFERENCE($,'Ac_15_50_52','Metalwork surveying',#1005,$,$); -#1014=IFCCLASSIFICATIONREFERENCE($,'Ac_15_50_73','Roof surveying',#1005,$,$); -#1015=IFCCLASSIFICATIONREFERENCE($,'Ac_15_50_85','Structural surveying',#1005,$,$); -#1016=IFCCLASSIFICATIONREFERENCE($,'Ac_15_50_90','Timber surveying',#1005,$,$); -#1017=IFCCLASSIFICATIONREFERENCE($,'Ac_15_55','Performance surveying',#948,$,$); -#1018=IFCCLASSIFICATIONREFERENCE($,'Ac_15_55_02','Access auditing',#1017,$,$); -#1019=IFCCLASSIFICATIONREFERENCE($,'Ac_15_55_04','Acoustics and noise transfer surveying',#1017,$,$); -#1020=IFCCLASSIFICATIONREFERENCE($,'Ac_15_55_06','Airtightness surveying',#1017,$,$); -#1021=IFCCLASSIFICATIONREFERENCE($,'Ac_15_55_26','Energy assessment surveying',#1017,$,$); -#1022=IFCCLASSIFICATIONREFERENCE($,'Ac_15_55_30','Fire protection surveying',#1017,$,$); -#1023=IFCCLASSIFICATIONREFERENCE($,'Ac_15_55_75','Security auditing',#1017,$,$); -#1024=IFCCLASSIFICATIONREFERENCE($,'Ac_15_60','Rail track surveying',#948,$,$); -#1025=IFCCLASSIFICATIONREFERENCE($,'Ac_15_70','Road and bridge surveying',#948,$,$); -#1026=IFCCLASSIFICATIONREFERENCE($,'Ac_15_70_70','Road safety auditing',#1025,$,$); -#1027=IFCCLASSIFICATIONREFERENCE($,'Ac_15_70_90','Traffic surveying',#1025,$,$); -#1028=IFCCLASSIFICATIONREFERENCE($,'Ac_15_75','Ground investigating',#948,$,$); -#1029=IFCCLASSIFICATIONREFERENCE($,'Ac_15_75_20','Geochemical surveying',#1028,$,$); -#1030=IFCCLASSIFICATIONREFERENCE($,'Ac_15_75_25','Geoenvironmental exploratory investigating',#1028,$,$); -#1031=IFCCLASSIFICATIONREFERENCE($,'Ac_15_75_30','Geoenvironmental ground investigating',#1028,$,$); -#1032=IFCCLASSIFICATIONREFERENCE($,'Ac_15_75_35','Geological boundaries surveying',#1028,$,$); -#1033=IFCCLASSIFICATIONREFERENCE($,'Ac_15_75_40','Geological faults surveying',#1028,$,$); -#1034=IFCCLASSIFICATIONREFERENCE($,'Ac_15_75_45','Geological surveying',#1028,$,$); -#1035=IFCCLASSIFICATIONREFERENCE($,'Ac_15_75_50','Geotechnical ground investigating',#1028,$,$); -#1036=IFCCLASSIFICATIONREFERENCE($,'Ac_15_75_55','Geotechnical substructure investigating',#1028,$,$); -#1037=IFCCLASSIFICATIONREFERENCE($,'Ac_15_75_60','Ground levels surveying',#1028,$,$); -#1038=IFCCLASSIFICATIONREFERENCE($,'Ac_15_75_65','Ground water table surveying',#1028,$,$); -#1039=IFCCLASSIFICATIONREFERENCE($,'Ac_15_75_70','Preliminary site investigating',#1028,$,$); -#1040=IFCCLASSIFICATIONREFERENCE($,'Ac_15_75_80','Soil surveying',#1028,$,$); -#1041=IFCCLASSIFICATIONREFERENCE($,'Ac_15_80','Site surveying',#948,$,$); -#1042=IFCCLASSIFICATIONREFERENCE($,'Ac_15_80_65','Preliminary site surveying',#1041,$,$); -#1043=IFCCLASSIFICATIONREFERENCE($,'Ac_15_80_92','Utilities surveying',#1041,$,$); -#1044=IFCCLASSIFICATIONREFERENCE($,'Ac_15_90','Tunnel surveying',#948,$,$); -#1045=IFCCLASSIFICATIONREFERENCE($,'Ac_20','Administrative, commercial and protective services activities',#850,$,$); -#1046=IFCCLASSIFICATIONREFERENCE($,'Ac_20_10','Legislative activities',#1045,$,$); -#1047=IFCCLASSIFICATIONREFERENCE($,'Ac_20_10_47','Legislating activities',#1046,$,$); -#1048=IFCCLASSIFICATIONREFERENCE($,'Ac_20_10_66','Public viewing of legislating activities',#1046,$,$); -#1049=IFCCLASSIFICATIONREFERENCE($,'Ac_20_15','Administrative office activities',#1045,$,$); -#1050=IFCCLASSIFICATIONREFERENCE($,'Ac_20_15_15','Counter service',#1049,$,$); -#1051=IFCCLASSIFICATIONREFERENCE($,'Ac_20_15_22','Desk-based office tasks',#1049,$,$); -#1052=IFCCLASSIFICATIONREFERENCE($,'Ac_20_15_50','Meetings',#1049,$,$); -#1053=IFCCLASSIFICATIONREFERENCE($,'Ac_20_15_59','Office maintenance tasks',#1049,$,$); -#1054=IFCCLASSIFICATIONREFERENCE($,'Ac_20_15_71','Reception tasks',#1049,$,$); -#1055=IFCCLASSIFICATIONREFERENCE($,'Ac_20_45','Motor vehicle maintenance and fuelling activities',#1045,$,$); -#1056=IFCCLASSIFICATIONREFERENCE($,'Ac_20_45_30','Fuel station air and water dispensing',#1055,$,$); -#1057=IFCCLASSIFICATIONREFERENCE($,'Ac_20_45_31','Fuel station fuel storing',#1055,$,$); -#1058=IFCCLASSIFICATIONREFERENCE($,'Ac_20_45_51','Motor vehicle fuelling',#1055,$,$); -#1059=IFCCLASSIFICATIONREFERENCE($,'Ac_20_45_53','Motor vehicle maintaining',#1055,$,$); -#1060=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50','Commercial activities',#1045,$,$); -#1061=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_03','Ambient products wholesale selling',#1060,$,$); -#1062=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_05','Auctioning',#1060,$,$); -#1063=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_12','Checking out and paying',#1060,$,$); -#1064=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_22','Department store retail selling',#1060,$,$); -#1065=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_29','Financial and professional services activity',#1060,$,$); -#1066=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_32','Food and drink retail selling',#1060,$,$); -#1067=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_33','General retail selling',#1060,$,$); -#1068=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_36','Hair and beauty treatment activities',#1060,$,$); -#1069=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_45','Kiosk retail selling',#1060,$,$); -#1070=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_47','Livestock wholesale selling',#1060,$,$); -#1071=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_50','Mail order sorting and despatching',#1060,$,$); -#1072=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_51','Market retail selling',#1060,$,$); -#1073=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_55','Motor vehicle selling',#1060,$,$); -#1074=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_70','Refrigerated products wholesale selling',#1060,$,$); -#1075=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_85','Supermarket retail selling',#1060,$,$); -#1076=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_87','Tattooing and piercing',#1060,$,$); -#1077=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_90','Trying out goods',#1060,$,$); -#1078=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_96','Waste and scrap wholesale selling',#1060,$,$); -#1079=IFCCLASSIFICATIONREFERENCE($,'Ac_20_55','Postal communications activities',#1045,$,$); -#1080=IFCCLASSIFICATIONREFERENCE($,'Ac_20_55_45','Letter sorting',#1079,$,$); -#1081=IFCCLASSIFICATIONREFERENCE($,'Ac_20_55_60','Parcel sorting',#1079,$,$); -#1082=IFCCLASSIFICATIONREFERENCE($,'Ac_20_60','Military protective activities',#1045,$,$); -#1083=IFCCLASSIFICATIONREFERENCE($,'Ac_20_60_08','Bombardment sheltering',#1082,$,$); -#1084=IFCCLASSIFICATIONREFERENCE($,'Ac_20_60_70','Radioactive fallout sheltering',#1082,$,$); -#1085=IFCCLASSIFICATIONREFERENCE($,'Ac_20_62','Parade activities',#1045,$,$); -#1086=IFCCLASSIFICATIONREFERENCE($,'Ac_20_62_65','Parading',#1085,$,$); -#1087=IFCCLASSIFICATIONREFERENCE($,'Ac_20_65','Law enforcement activities',#1045,$,$); -#1088=IFCCLASSIFICATIONREFERENCE($,'Ac_20_65_08','Breathalyzing',#1087,$,$); -#1089=IFCCLASSIFICATIONREFERENCE($,'Ac_20_65_15','Counter terrorism activities',#1087,$,$); -#1090=IFCCLASSIFICATIONREFERENCE($,'Ac_20_65_19','Custody activities',#1087,$,$); -#1091=IFCCLASSIFICATIONREFERENCE($,'Ac_20_65_40','Identification parading',#1087,$,$); -#1092=IFCCLASSIFICATIONREFERENCE($,'Ac_20_65_59','Operational activities',#1087,$,$); -#1093=IFCCLASSIFICATIONREFERENCE($,'Ac_20_65_65','Police detaining',#1087,$,$); -#1094=IFCCLASSIFICATIONREFERENCE($,'Ac_20_65_87','Testing for illegal substances',#1087,$,$); -#1095=IFCCLASSIFICATIONREFERENCE($,'Ac_20_65_94','Victim examining',#1087,$,$); -#1096=IFCCLASSIFICATIONREFERENCE($,'Ac_20_70','Judicial activities',#1045,$,$); -#1097=IFCCLASSIFICATIONREFERENCE($,'Ac_20_70_15','Conducting trials and hearings',#1096,$,$); -#1098=IFCCLASSIFICATIONREFERENCE($,'Ac_20_70_23','Defendant seating',#1096,$,$); -#1099=IFCCLASSIFICATIONREFERENCE($,'Ac_20_70_27','Evidence drying',#1096,$,$); -#1100=IFCCLASSIFICATIONREFERENCE($,'Ac_20_70_41','Judicial seating',#1096,$,$); -#1101=IFCCLASSIFICATIONREFERENCE($,'Ac_20_70_44','Jury seating',#1096,$,$); -#1102=IFCCLASSIFICATIONREFERENCE($,'Ac_20_70_68','Public gallery viewing',#1096,$,$); -#1103=IFCCLASSIFICATIONREFERENCE($,'Ac_20_70_93','Victim supporting',#1096,$,$); -#1104=IFCCLASSIFICATIONREFERENCE($,'Ac_20_70_94','Vulnerable victim supporting',#1096,$,$); -#1105=IFCCLASSIFICATIONREFERENCE($,'Ac_20_70_95','Vulnerable witness supporting',#1096,$,$); -#1106=IFCCLASSIFICATIONREFERENCE($,'Ac_20_70_97','Witness standing',#1096,$,$); -#1107=IFCCLASSIFICATIONREFERENCE($,'Ac_20_70_98','Witness supporting',#1096,$,$); -#1108=IFCCLASSIFICATIONREFERENCE($,'Ac_20_75','Detention activities',#1045,$,$); -#1109=IFCCLASSIFICATIONREFERENCE($,'Ac_20_75_12','Close supervising',#1108,$,$); -#1110=IFCCLASSIFICATIONREFERENCE($,'Ac_20_75_15','Communal inmate day activities',#1108,$,$); -#1111=IFCCLASSIFICATIONREFERENCE($,'Ac_20_75_20','Detainee exercising',#1108,$,$); -#1112=IFCCLASSIFICATIONREFERENCE($,'Ac_20_75_22','Detainee processing',#1108,$,$); -#1113=IFCCLASSIFICATIONREFERENCE($,'Ac_20_75_35','Guarding detainees',#1108,$,$); -#1114=IFCCLASSIFICATIONREFERENCE($,'Ac_20_75_38','Holding of prisoners',#1108,$,$); -#1115=IFCCLASSIFICATIONREFERENCE($,'Ac_20_75_41','Inmate exercising',#1108,$,$); -#1116=IFCCLASSIFICATIONREFERENCE($,'Ac_20_75_44','Juvenile detaining',#1108,$,$); -#1117=IFCCLASSIFICATIONREFERENCE($,'Ac_20_75_67','Prison detaining',#1108,$,$); -#1118=IFCCLASSIFICATIONREFERENCE($,'Ac_20_75_75','Secure entering and exiting',#1108,$,$); -#1119=IFCCLASSIFICATIONREFERENCE($,'Ac_20_75_77','Secure visiting',#1108,$,$); -#1120=IFCCLASSIFICATIONREFERENCE($,'Ac_20_75_95','Vehicle impounding',#1108,$,$); -#1121=IFCCLASSIFICATIONREFERENCE($,'Ac_20_80','Weapons training activities',#1045,$,$); -#1122=IFCCLASSIFICATIONREFERENCE($,'Ac_20_80_29','Firearms training',#1121,$,$); -#1123=IFCCLASSIFICATIONREFERENCE($,'Ac_20_80_31','Firing of weapons',#1121,$,$); -#1124=IFCCLASSIFICATIONREFERENCE($,'Ac_20_85','Security activities',#1045,$,$); -#1125=IFCCLASSIFICATIONREFERENCE($,'Ac_20_85_08','Biometric identifying',#1124,$,$); -#1126=IFCCLASSIFICATIONREFERENCE($,'Ac_20_85_63','Pedestrian security checking',#1124,$,$); -#1127=IFCCLASSIFICATIONREFERENCE($,'Ac_20_85_77','Secure activities',#1124,$,$); -#1128=IFCCLASSIFICATIONREFERENCE($,'Ac_20_85_79','Sensitive activities',#1124,$,$); -#1129=IFCCLASSIFICATIONREFERENCE($,'Ac_20_85_95','Vehicular security checking',#1124,$,$); -#1130=IFCCLASSIFICATIONREFERENCE($,'Ac_20_90','Incident support activities',#1045,$,$); -#1131=IFCCLASSIFICATIONREFERENCE($,'Ac_20_90_31','Fire training',#1130,$,$); -#1132=IFCCLASSIFICATIONREFERENCE($,'Ac_20_90_41','Incident prevention',#1130,$,$); -#1133=IFCCLASSIFICATIONREFERENCE($,'Ac_20_90_42','Incident support',#1130,$,$); -#1134=IFCCLASSIFICATIONREFERENCE($,'Ac_20_90_78','Sheltering from fire',#1130,$,$); -#1135=IFCCLASSIFICATIONREFERENCE($,'Ac_25','Cultural, educational, scientific and information activities',#850,$,$); -#1136=IFCCLASSIFICATIONREFERENCE($,'Ac_25_05','Commemoration activities',#1135,$,$); -#1137=IFCCLASSIFICATIONREFERENCE($,'Ac_25_05_15','Commemoration events',#1136,$,$); -#1138=IFCCLASSIFICATIONREFERENCE($,'Ac_25_10','Educational activities',#1135,$,$); -#1139=IFCCLASSIFICATIONREFERENCE($,'Ac_25_10_05','Assembling',#1138,$,$); -#1140=IFCCLASSIFICATIONREFERENCE($,'Ac_25_10_15','Communal educational activities',#1138,$,$); -#1141=IFCCLASSIFICATIONREFERENCE($,'Ac_25_10_26','Driving tuition',#1138,$,$); -#1142=IFCCLASSIFICATIONREFERENCE($,'Ac_25_10_35','Group work',#1138,$,$); -#1143=IFCCLASSIFICATIONREFERENCE($,'Ac_25_10_47','Lecturing',#1138,$,$); -#1144=IFCCLASSIFICATIONREFERENCE($,'Ac_25_10_71','Researching',#1138,$,$); -#1145=IFCCLASSIFICATIONREFERENCE($,'Ac_25_10_78','Seminar activities',#1138,$,$); -#1146=IFCCLASSIFICATIONREFERENCE($,'Ac_25_10_84','Studying',#1138,$,$); -#1147=IFCCLASSIFICATIONREFERENCE($,'Ac_25_10_88','Teaching',#1138,$,$); -#1148=IFCCLASSIFICATIONREFERENCE($,'Ac_25_20','Design and craft activities',#1135,$,$); -#1149=IFCCLASSIFICATIONREFERENCE($,'Ac_25_20_13','Ceramics making',#1148,$,$); -#1150=IFCCLASSIFICATIONREFERENCE($,'Ac_25_20_15','Craft activities',#1148,$,$); -#1151=IFCCLASSIFICATIONREFERENCE($,'Ac_25_20_21','Designing',#1148,$,$); -#1152=IFCCLASSIFICATIONREFERENCE($,'Ac_25_20_24','Drawing',#1148,$,$); -#1153=IFCCLASSIFICATIONREFERENCE($,'Ac_25_20_60','Painting',#1148,$,$); -#1154=IFCCLASSIFICATIONREFERENCE($,'Ac_25_20_88','Technical drawing',#1148,$,$); -#1155=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30','Scientific and laboratory activities',#1135,$,$); -#1156=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_02','Anechoic chamber activities',#1155,$,$); -#1157=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_04','Astronomy activities',#1155,$,$); -#1158=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_07','Biology activities',#1155,$,$); -#1159=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_10','Bioscience activities',#1155,$,$); -#1160=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_13','Chemistry activities',#1155,$,$); -#1161=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_15','Clinical biochemistry activities',#1155,$,$); -#1162=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_16','Clinical microbiology activities',#1155,$,$); -#1163=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_17','Clinical pathology activities',#1155,$,$); -#1164=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_19','Containment activities',#1155,$,$); -#1165=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_21','Dark room activities',#1155,$,$); -#1166=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_22','Dental laboratory activities',#1155,$,$); -#1167=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_23','Dissection',#1155,$,$); -#1168=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_26','Earth sciences activities',#1155,$,$); -#1169=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_27','Engineering activities',#1155,$,$); -#1170=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_28','Experiment controlling',#1155,$,$); -#1171=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_29','Flow cytometry activities',#1155,$,$); -#1172=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_30','Food testing',#1155,$,$); -#1173=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_31','Forensic science activities',#1155,$,$); -#1174=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_33','Geology activities',#1155,$,$); -#1175=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_36','Hyperbaric chamber activities',#1155,$,$); -#1176=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_46','Laboratory cold activities',#1155,$,$); -#1177=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_47','Laboratory warm activities',#1155,$,$); -#1178=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_50','Material testing',#1155,$,$); -#1179=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_66','Physics activities',#1155,$,$); -#1180=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_68','Psychology activities',#1155,$,$); -#1181=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_70','Radiation shielded activities',#1155,$,$); -#1182=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_72','Results interpreting',#1155,$,$); -#1183=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_76','Scientific instrument activities',#1155,$,$); -#1184=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_78','Seismograph activities',#1155,$,$); -#1185=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_85','Sterilizing activities',#1155,$,$); -#1186=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_89','Tissue culturing',#1155,$,$); -#1187=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_90','Toxicology activities',#1155,$,$); -#1188=IFCCLASSIFICATIONREFERENCE($,'Ac_25_50','Exhibition activities',#1135,$,$); -#1189=IFCCLASSIFICATIONREFERENCE($,'Ac_25_50_04','Art exhibiting',#1188,$,$); -#1190=IFCCLASSIFICATIONREFERENCE($,'Ac_25_50_15','Collection exhibiting',#1188,$,$); -#1191=IFCCLASSIFICATIONREFERENCE($,'Ac_25_50_16','Conservation of art and artefacts',#1188,$,$); -#1192=IFCCLASSIFICATIONREFERENCE($,'Ac_25_50_21','Diorama exhibiting',#1188,$,$); -#1193=IFCCLASSIFICATIONREFERENCE($,'Ac_25_50_29','Fauna exhibiting',#1188,$,$); -#1194=IFCCLASSIFICATIONREFERENCE($,'Ac_25_50_31','Flora exhibiting',#1188,$,$); -#1195=IFCCLASSIFICATIONREFERENCE($,'Ac_25_50_65','Projecting representations of the night sky',#1188,$,$); -#1196=IFCCLASSIFICATIONREFERENCE($,'Ac_25_50_73','Sculpture exhibiting',#1188,$,$); -#1197=IFCCLASSIFICATIONREFERENCE($,'Ac_25_50_94','Viewing activities',#1188,$,$); -#1198=IFCCLASSIFICATIONREFERENCE($,'Ac_25_70','Information activities',#1135,$,$); -#1199=IFCCLASSIFICATIONREFERENCE($,'Ac_25_70_04','Archiving',#1198,$,$); -#1200=IFCCLASSIFICATIONREFERENCE($,'Ac_25_70_05','Audio-visual studying',#1198,$,$); -#1201=IFCCLASSIFICATIONREFERENCE($,'Ac_25_70_11','Cataloguing',#1198,$,$); -#1202=IFCCLASSIFICATIONREFERENCE($,'Ac_25_70_23','Domestic book storing and reading',#1198,$,$); -#1203=IFCCLASSIFICATIONREFERENCE($,'Ac_25_70_30','Film storing',#1198,$,$); -#1204=IFCCLASSIFICATIONREFERENCE($,'Ac_25_70_47','Library storing',#1198,$,$); -#1205=IFCCLASSIFICATIONREFERENCE($,'Ac_25_70_71','Reading',#1198,$,$); -#1206=IFCCLASSIFICATIONREFERENCE($,'Ac_25_70_72','Records storing',#1198,$,$); -#1207=IFCCLASSIFICATIONREFERENCE($,'Ac_25_70_76','Scanning',#1198,$,$); -#1208=IFCCLASSIFICATIONREFERENCE($,'Ac_25_90','Worship activities',#1135,$,$); -#1209=IFCCLASSIFICATIONREFERENCE($,'Ac_25_90_12','Ceremonial worship activities',#1208,$,$); -#1210=IFCCLASSIFICATIONREFERENCE($,'Ac_25_90_15','Conducting acts of worship',#1208,$,$); -#1211=IFCCLASSIFICATIONREFERENCE($,'Ac_25_90_60','Pastoral care',#1208,$,$); -#1212=IFCCLASSIFICATIONREFERENCE($,'Ac_25_90_67','Preparing for acts of worship',#1208,$,$); -#1213=IFCCLASSIFICATIONREFERENCE($,'Ac_30','Industrial activities',#850,$,$); -#1214=IFCCLASSIFICATIONREFERENCE($,'Ac_30_10','Mineral extraction activities',#1213,$,$); -#1215=IFCCLASSIFICATIONREFERENCE($,'Ac_30_10_57','Offshore oil and gas drilling',#1214,$,$); -#1216=IFCCLASSIFICATIONREFERENCE($,'Ac_30_10_59','Onshore oil and gas drilling',#1214,$,$); -#1217=IFCCLASSIFICATIONREFERENCE($,'Ac_30_10_60','Opencast mining',#1214,$,$); -#1218=IFCCLASSIFICATIONREFERENCE($,'Ac_30_10_69','Quarrying',#1214,$,$); -#1219=IFCCLASSIFICATIONREFERENCE($,'Ac_30_10_91','Underground mining',#1214,$,$); -#1220=IFCCLASSIFICATIONREFERENCE($,'Ac_30_10_93','Underground mine accessing',#1214,$,$); -#1221=IFCCLASSIFICATIONREFERENCE($,'Ac_30_10_94','Underground mine tunnelling',#1214,$,$); -#1222=IFCCLASSIFICATIONREFERENCE($,'Ac_30_20','Nuclear and chemical management activities',#1213,$,$); -#1223=IFCCLASSIFICATIONREFERENCE($,'Ac_30_20_30','High heat highly enriched uranium radioactive waste managing',#1222,$,$); -#1224=IFCCLASSIFICATIONREFERENCE($,'Ac_30_20_35','High heat mixed oxide fuel radioactive waste managing',#1222,$,$); -#1225=IFCCLASSIFICATIONREFERENCE($,'Ac_30_20_40','High heat plutonium radioactive waste managing',#1222,$,$); -#1226=IFCCLASSIFICATIONREFERENCE($,'Ac_30_20_45','High heat radioactive waste managing',#1222,$,$); -#1227=IFCCLASSIFICATIONREFERENCE($,'Ac_30_20_50','High heat spent fuel radioactive waste managing',#1222,$,$); -#1228=IFCCLASSIFICATIONREFERENCE($,'Ac_30_20_60','Low heat depleted natural low enrichment uranium managing',#1222,$,$); -#1229=IFCCLASSIFICATIONREFERENCE($,'Ac_30_20_65','Low heat robust shielded radioactive waste managing',#1222,$,$); -#1230=IFCCLASSIFICATIONREFERENCE($,'Ac_30_20_70','Low heat shielded radioactive waste managing',#1222,$,$); -#1231=IFCCLASSIFICATIONREFERENCE($,'Ac_30_20_75','Low heat unshielded radioactive waste managing',#1222,$,$); -#1232=IFCCLASSIFICATIONREFERENCE($,'Ac_30_30','Mineral processing activities',#1213,$,$); -#1233=IFCCLASSIFICATIONREFERENCE($,'Ac_30_30_33','Gas processing',#1232,$,$); -#1234=IFCCLASSIFICATIONREFERENCE($,'Ac_30_30_58','Oil processing',#1232,$,$); -#1235=IFCCLASSIFICATIONREFERENCE($,'Ac_30_30_59','Ore processing',#1232,$,$); -#1236=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40','Animal and plant products processing activities',#1213,$,$); -#1237=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_06','Baking',#1236,$,$); -#1238=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_07','Bottling',#1236,$,$); -#1239=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_09','Brewing',#1236,$,$); -#1240=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_10','Butter-making',#1236,$,$); -#1241=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_11','Canning',#1236,$,$); -#1242=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_18','Cheese making',#1236,$,$); -#1243=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_22','Distilling',#1236,$,$); -#1244=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_30','Fish processing',#1236,$,$); -#1245=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_32','Fresh fruit and vegetable packing',#1236,$,$); -#1246=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_44','Juicing',#1236,$,$); -#1247=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_52','Meat processing',#1236,$,$); -#1248=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_54','Milk processing',#1236,$,$); -#1249=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_55','Milling',#1236,$,$); -#1250=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_63','Plant fibre sorting',#1236,$,$); -#1251=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_65','Poultry processing',#1236,$,$); -#1252=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_80','Slaughtering',#1236,$,$); -#1253=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_87','Tanning',#1236,$,$); -#1254=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_88','Threshing',#1236,$,$); -#1255=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_89','Timber sawing',#1236,$,$); -#1256=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_90','Tobacco drying',#1236,$,$); -#1257=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_96','Wine making',#1236,$,$); -#1258=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_98','Wool sorting',#1236,$,$); -#1259=IFCCLASSIFICATIONREFERENCE($,'Ac_30_50','Manufacturing activities',#1213,$,$); -#1260=IFCCLASSIFICATIONREFERENCE($,'Ac_30_50_27','Electronics clean activities',#1259,$,$); -#1261=IFCCLASSIFICATIONREFERENCE($,'Ac_30_50_30','Heavy industrial activities',#1259,$,$); -#1262=IFCCLASSIFICATIONREFERENCE($,'Ac_30_50_53','Light industrial activities',#1259,$,$); -#1263=IFCCLASSIFICATIONREFERENCE($,'Ac_30_50_60','Packaging',#1259,$,$); -#1264=IFCCLASSIFICATIONREFERENCE($,'Ac_30_50_61','Paint spraying',#1259,$,$); -#1265=IFCCLASSIFICATIONREFERENCE($,'Ac_30_50_64','Printing',#1259,$,$); -#1266=IFCCLASSIFICATIONREFERENCE($,'Ac_30_60','Cleaning and maintenance activities',#1213,$,$); -#1267=IFCCLASSIFICATIONREFERENCE($,'Ac_30_60_12','Cleaning',#1266,$,$); -#1268=IFCCLASSIFICATIONREFERENCE($,'Ac_30_60_13','Clothes drying and airing',#1266,$,$); -#1269=IFCCLASSIFICATIONREFERENCE($,'Ac_30_60_15','Commercial laundering',#1266,$,$); -#1270=IFCCLASSIFICATIONREFERENCE($,'Ac_30_60_22','Decontaminating',#1266,$,$); -#1271=IFCCLASSIFICATIONREFERENCE($,'Ac_30_60_23','Domestic laundering',#1266,$,$); -#1272=IFCCLASSIFICATIONREFERENCE($,'Ac_30_60_24','Dry cleaning',#1266,$,$); -#1273=IFCCLASSIFICATIONREFERENCE($,'Ac_30_60_42','Ironing',#1266,$,$); -#1274=IFCCLASSIFICATIONREFERENCE($,'Ac_30_60_47','Laundering',#1266,$,$); -#1275=IFCCLASSIFICATIONREFERENCE($,'Ac_30_60_75','Service laundering',#1266,$,$); -#1276=IFCCLASSIFICATIONREFERENCE($,'Ac_30_60_94','Vehicle washing',#1266,$,$); -#1277=IFCCLASSIFICATIONREFERENCE($,'Ac_30_60_96','Washing up',#1266,$,$); -#1278=IFCCLASSIFICATIONREFERENCE($,'Ac_30_80','Kinetic power generation',#1213,$,$); -#1279=IFCCLASSIFICATIONREFERENCE($,'Ac_30_85','Marine and water storage and maintenance activities',#1213,$,$); -#1280=IFCCLASSIFICATIONREFERENCE($,'Ac_30_85_08','Boat repairing',#1279,$,$); -#1281=IFCCLASSIFICATIONREFERENCE($,'Ac_30_85_24','Dry dock ship repairing',#1279,$,$); -#1282=IFCCLASSIFICATIONREFERENCE($,'Ac_30_85_30','Floating dock ship repairing',#1279,$,$); -#1283=IFCCLASSIFICATIONREFERENCE($,'Ac_30_85_97','Wet dock ship repairing',#1279,$,$); -#1284=IFCCLASSIFICATIONREFERENCE($,'Ac_30_90','Warehousing and distribution activities',#1213,$,$); -#1285=IFCCLASSIFICATIONREFERENCE($,'Ac_30_90_33','Goods delivery',#1284,$,$); -#1286=IFCCLASSIFICATIONREFERENCE($,'Ac_30_90_48','Loading and unloading',#1284,$,$); -#1287=IFCCLASSIFICATIONREFERENCE($,'Ac_30_90_80','Sorting and distributing',#1284,$,$); -#1288=IFCCLASSIFICATIONREFERENCE($,'Ac_30_90_96','Warehousing',#1284,$,$); -#1289=IFCCLASSIFICATIONREFERENCE($,'Ac_32','Water and land management activities',#850,$,$); -#1290=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10','Agricultural and horticultural activities',#1289,$,$); -#1291=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_02','Agricultural maintenance',#1290,$,$); -#1292=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_26','Farm yard activities',#1290,$,$); -#1293=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_27','Fertilizing',#1290,$,$); -#1294=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_29','Fish cultivating',#1290,$,$); -#1295=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_34','Glasshouse growing',#1290,$,$); -#1296=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_35','Harvesting',#1290,$,$); -#1297=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_36','Hedge laying',#1290,$,$); -#1298=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_38','Horticultural activities',#1290,$,$); -#1299=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_42','Irrigating',#1290,$,$); -#1300=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_47','Livestock activities',#1290,$,$); -#1301=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_52','Milking',#1290,$,$); -#1302=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_55','Mushroom cultivating',#1290,$,$); -#1303=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_61','Pest management',#1290,$,$); -#1304=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_64','Ploughing',#1290,$,$); -#1305=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_66','Poultry rearing',#1290,$,$); -#1306=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_68','Propagating',#1290,$,$); -#1307=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_70','Pruning',#1290,$,$); -#1308=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_77','Sheep shearing',#1290,$,$); -#1309=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_78','Sheep dipping',#1290,$,$); -#1310=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_79','Silviculture',#1290,$,$); -#1311=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_80','Sowing',#1290,$,$); -#1312=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_94','Viticulture',#1290,$,$); -#1313=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_96','Weed management',#1290,$,$); -#1314=IFCCLASSIFICATIONREFERENCE($,'Ac_32_50','Marine and water activities',#1289,$,$); -#1315=IFCCLASSIFICATIONREFERENCE($,'Ac_32_50_30','Flood defending',#1314,$,$); -#1316=IFCCLASSIFICATIONREFERENCE($,'Ac_32_50_38','Harbour protecting',#1314,$,$); -#1317=IFCCLASSIFICATIONREFERENCE($,'Ac_32_50_94','Vessel berthing',#1314,$,$); -#1318=IFCCLASSIFICATIONREFERENCE($,'Ac_32_50_95','Vessel launching',#1314,$,$); -#1319=IFCCLASSIFICATIONREFERENCE($,'Ac_32_60','Natural spaces activities',#1289,$,$); -#1320=IFCCLASSIFICATIONREFERENCE($,'Ac_32_60_27','Erosion',#1319,$,$); -#1321=IFCCLASSIFICATIONREFERENCE($,'Ac_32_60_30','Flooding',#1319,$,$); -#1322=IFCCLASSIFICATIONREFERENCE($,'Ac_35','Medical, health, welfare and sanitary activities',#850,$,$); -#1323=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10','Medical activities',#1322,$,$); -#1324=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_08','Birthing',#1323,$,$); -#1325=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_10','Burns treating',#1323,$,$); -#1326=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_15','Consulting',#1323,$,$); -#1327=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_31','First aiding',#1323,$,$); -#1328=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_36','Hearing testing',#1323,$,$); -#1329=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_39','Hydrotherapy',#1323,$,$); -#1330=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_42','Intensive caring',#1323,$,$); -#1331=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_43','Isolation caring',#1323,$,$); -#1332=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_51','Medical scanning',#1323,$,$); -#1333=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_53','Midwifery',#1323,$,$); -#1334=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_57','Nursing',#1323,$,$); -#1335=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_58','Occupational therapy',#1323,$,$); -#1336=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_61','Patient examining',#1323,$,$); -#1337=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_62','Patient screening',#1323,$,$); -#1338=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_64','Pharmaceutical dispensing',#1323,$,$); -#1339=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_65','Phototherapy',#1323,$,$); -#1340=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_66','Physiotherapy',#1323,$,$); -#1341=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_70','Radiography',#1323,$,$); -#1342=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_71','Radiotherapy',#1323,$,$); -#1343=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_74','Rehabilitating',#1323,$,$); -#1344=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_85','Surgical operating',#1323,$,$); -#1345=IFCCLASSIFICATIONREFERENCE($,'Ac_35_50','Welfare activities',#1322,$,$); -#1346=IFCCLASSIFICATIONREFERENCE($,'Ac_35_50_21','Day care',#1345,$,$); -#1347=IFCCLASSIFICATIONREFERENCE($,'Ac_35_50_42','Infant caring',#1345,$,$); -#1348=IFCCLASSIFICATIONREFERENCE($,'Ac_35_60','Food management activities',#1322,$,$); -#1349=IFCCLASSIFICATIONREFERENCE($,'Ac_35_60_16','Cooking',#1348,$,$); -#1350=IFCCLASSIFICATIONREFERENCE($,'Ac_35_60_30','Food preparation',#1348,$,$); -#1351=IFCCLASSIFICATIONREFERENCE($,'Ac_35_60_31','Food serving',#1348,$,$); -#1352=IFCCLASSIFICATIONREFERENCE($,'Ac_35_70','Funerary activities',#1322,$,$); -#1353=IFCCLASSIFICATIONREFERENCE($,'Ac_35_70_04','Ash urn storing',#1352,$,$); -#1354=IFCCLASSIFICATIONREFERENCE($,'Ac_35_70_10','Burial',#1352,$,$); -#1355=IFCCLASSIFICATIONREFERENCE($,'Ac_35_70_18','Cremating',#1352,$,$); -#1356=IFCCLASSIFICATIONREFERENCE($,'Ac_35_70_42','Interment in a vault or tomb',#1352,$,$); -#1357=IFCCLASSIFICATIONREFERENCE($,'Ac_35_80','Sanitary activities',#1322,$,$); -#1358=IFCCLASSIFICATIONREFERENCE($,'Ac_35_80_06','Baby changing',#1357,$,$); -#1359=IFCCLASSIFICATIONREFERENCE($,'Ac_35_80_07','Bathing',#1357,$,$); -#1360=IFCCLASSIFICATIONREFERENCE($,'Ac_35_80_80','Showering',#1357,$,$); -#1361=IFCCLASSIFICATIONREFERENCE($,'Ac_35_85','Animal activities',#1322,$,$); -#1362=IFCCLASSIFICATIONREFERENCE($,'Ac_35_85_02','Animal care',#1361,$,$); -#1363=IFCCLASSIFICATIONREFERENCE($,'Ac_35_85_04','Animal exercising',#1361,$,$); -#1364=IFCCLASSIFICATIONREFERENCE($,'Ac_35_85_88','Tack maintaining',#1361,$,$); -#1365=IFCCLASSIFICATIONREFERENCE($,'Ac_35_90','Animal medical, health, welfare, funerary and sanitary activities',#1322,$,$); -#1366=IFCCLASSIFICATIONREFERENCE($,'Ac_35_90_25','Animal drug dispensing',#1365,$,$); -#1367=IFCCLASSIFICATIONREFERENCE($,'Ac_35_90_32','Animal funerary activities',#1365,$,$); -#1368=IFCCLASSIFICATIONREFERENCE($,'Ac_35_90_34','Animal grooming',#1365,$,$); -#1369=IFCCLASSIFICATIONREFERENCE($,'Ac_35_90_39','Animal hydrotherapy',#1365,$,$); -#1370=IFCCLASSIFICATIONREFERENCE($,'Ac_35_90_59','Veterinary caring',#1365,$,$); -#1371=IFCCLASSIFICATIONREFERENCE($,'Ac_40','Recreational activities',#850,$,$); -#1372=IFCCLASSIFICATIONREFERENCE($,'Ac_40_05','Amusement activities',#1371,$,$); -#1373=IFCCLASSIFICATIONREFERENCE($,'Ac_40_05_03','Amusement arcade activities',#1372,$,$); -#1374=IFCCLASSIFICATIONREFERENCE($,'Ac_40_05_33','Gambling',#1372,$,$); -#1375=IFCCLASSIFICATIONREFERENCE($,'Ac_40_05_42','Indoor fairground riding',#1372,$,$); -#1376=IFCCLASSIFICATIONREFERENCE($,'Ac_40_05_58','Observing',#1372,$,$); -#1377=IFCCLASSIFICATIONREFERENCE($,'Ac_40_05_59','Outdoor activities',#1372,$,$); -#1378=IFCCLASSIFICATIONREFERENCE($,'Ac_40_05_60','Outdoor fairground riding',#1372,$,$); -#1379=IFCCLASSIFICATIONREFERENCE($,'Ac_40_05_63','Playing',#1372,$,$); -#1380=IFCCLASSIFICATIONREFERENCE($,'Ac_40_05_89','Theme park activities',#1372,$,$); -#1381=IFCCLASSIFICATIONREFERENCE($,'Ac_40_20','Dining activities',#1371,$,$); -#1382=IFCCLASSIFICATIONREFERENCE($,'Ac_40_20_09','Beverage dispensing',#1381,$,$); -#1383=IFCCLASSIFICATIONREFERENCE($,'Ac_40_20_27','Enclosed dining',#1381,$,$); -#1384=IFCCLASSIFICATIONREFERENCE($,'Ac_40_20_28','Food dispensing',#1381,$,$); -#1385=IFCCLASSIFICATIONREFERENCE($,'Ac_40_20_59','Outdoor dining',#1381,$,$); -#1386=IFCCLASSIFICATIONREFERENCE($,'Ac_40_35','Historic recreational activities',#1371,$,$); -#1387=IFCCLASSIFICATIONREFERENCE($,'Ac_40_35_37','Historic earthworks exploring',#1386,$,$); -#1388=IFCCLASSIFICATIONREFERENCE($,'Ac_40_35_38','Historic ruins exploring',#1386,$,$); -#1389=IFCCLASSIFICATIONREFERENCE($,'Ac_40_35_39','Historic sites exploring',#1386,$,$); -#1390=IFCCLASSIFICATIONREFERENCE($,'Ac_40_60','Performing arts performance activities',#1371,$,$); -#1391=IFCCLASSIFICATIONREFERENCE($,'Ac_40_60_13','Circus performing',#1390,$,$); -#1392=IFCCLASSIFICATIONREFERENCE($,'Ac_40_60_21','Dancing',#1390,$,$); -#1393=IFCCLASSIFICATIONREFERENCE($,'Ac_40_60_29','Fashion showing',#1390,$,$); -#1394=IFCCLASSIFICATIONREFERENCE($,'Ac_40_60_30','Filming',#1390,$,$); -#1395=IFCCLASSIFICATIONREFERENCE($,'Ac_40_60_31','Film screening',#1390,$,$); -#1396=IFCCLASSIFICATIONREFERENCE($,'Ac_40_60_38','Indoor music performing',#1390,$,$); -#1397=IFCCLASSIFICATIONREFERENCE($,'Ac_40_60_40','Indoor theatre activities',#1390,$,$); -#1398=IFCCLASSIFICATIONREFERENCE($,'Ac_40_60_55','Music recording',#1390,$,$); -#1399=IFCCLASSIFICATIONREFERENCE($,'Ac_40_60_58','Outdoor music performing',#1390,$,$); -#1400=IFCCLASSIFICATIONREFERENCE($,'Ac_40_60_59','Outdoor theatre activities',#1390,$,$); -#1401=IFCCLASSIFICATIONREFERENCE($,'Ac_40_65','Performing arts ancillary activities',#1371,$,$); -#1402=IFCCLASSIFICATIONREFERENCE($,'Ac_40_65_02','Amphitheatre seating',#1401,$,$); -#1403=IFCCLASSIFICATIONREFERENCE($,'Ac_40_65_03','Artiste changing and make-up activities',#1401,$,$); -#1404=IFCCLASSIFICATIONREFERENCE($,'Ac_40_65_04','Audience breaking out',#1401,$,$); -#1405=IFCCLASSIFICATIONREFERENCE($,'Ac_40_65_05','Audience seating',#1401,$,$); -#1406=IFCCLASSIFICATIONREFERENCE($,'Ac_40_65_06','Backstage activities',#1401,$,$); -#1407=IFCCLASSIFICATIONREFERENCE($,'Ac_40_65_55','Music recording controlling',#1401,$,$); -#1408=IFCCLASSIFICATIONREFERENCE($,'Ac_40_65_59','Overhead scenery storing',#1401,$,$); -#1409=IFCCLASSIFICATIONREFERENCE($,'Ac_40_65_76','Scenery controlling',#1401,$,$); -#1410=IFCCLASSIFICATIONREFERENCE($,'Ac_40_65_79','Sound controlling',#1401,$,$); -#1411=IFCCLASSIFICATIONREFERENCE($,'Ac_40_65_80','Sound excluding',#1401,$,$); -#1412=IFCCLASSIFICATIONREFERENCE($,'Ac_40_65_88','Theatrical lighting controlling',#1401,$,$); -#1413=IFCCLASSIFICATIONREFERENCE($,'Ac_40_65_89','Theatrical rehearsing',#1401,$,$); -#1414=IFCCLASSIFICATIONREFERENCE($,'Ac_42','Sports activities',#850,$,$); -#1415=IFCCLASSIFICATIONREFERENCE($,'Ac_42_15','Court, pitch and field sport activities',#1414,$,$); -#1416=IFCCLASSIFICATIONREFERENCE($,'Ac_42_15_30','Field athletics',#1415,$,$); -#1417=IFCCLASSIFICATIONREFERENCE($,'Ac_42_15_42','Indoor court sports',#1415,$,$); -#1418=IFCCLASSIFICATIONREFERENCE($,'Ac_42_15_58','Outdoor court sports',#1415,$,$); -#1419=IFCCLASSIFICATIONREFERENCE($,'Ac_42_15_59','Outdoor field sports',#1415,$,$); -#1420=IFCCLASSIFICATIONREFERENCE($,'Ac_42_15_90','Track athletics',#1415,$,$); -#1421=IFCCLASSIFICATIONREFERENCE($,'Ac_42_40','Indoor sports activities',#1414,$,$); -#1422=IFCCLASSIFICATIONREFERENCE($,'Ac_42_40_09','Bouldering',#1421,$,$); -#1423=IFCCLASSIFICATIONREFERENCE($,'Ac_42_40_14','Climbing wall activities',#1421,$,$); -#1424=IFCCLASSIFICATIONREFERENCE($,'Ac_42_40_28','Exercising',#1421,$,$); -#1425=IFCCLASSIFICATIONREFERENCE($,'Ac_42_40_37','Gymnastics',#1421,$,$); -#1426=IFCCLASSIFICATIONREFERENCE($,'Ac_42_40_79','Snooker, billiards and pool',#1421,$,$); -#1427=IFCCLASSIFICATIONREFERENCE($,'Ac_42_40_90','Ten pin bowling',#1421,$,$); -#1428=IFCCLASSIFICATIONREFERENCE($,'Ac_42_40_92','Track cycling',#1421,$,$); -#1429=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55','Outdoor sports activities',#1414,$,$); -#1430=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_01','Archery',#1429,$,$); -#1431=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_07','BMX cycling',#1429,$,$); -#1432=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_08','Bowling',#1429,$,$); -#1433=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_18','Cross-country cycling',#1429,$,$); -#1434=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_19','Cross-country rallying',#1429,$,$); -#1435=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_20','Cross-country running',#1429,$,$); -#1436=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_23','Dog racing',#1429,$,$); -#1437=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_26','Equestrian dressage',#1429,$,$); -#1438=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_27','Equestrian cross country eventing',#1429,$,$); -#1439=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_28','Equestrian show jumping',#1429,$,$); -#1440=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_30','Fishing',#1429,$,$); -#1441=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_34','Golfing',#1429,$,$); -#1442=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_39','Horse racing',#1429,$,$); -#1443=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_40','Hunting',#1429,$,$); -#1444=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_53','Motor racing',#1429,$,$); -#1445=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_58','Orienteering',#1429,$,$); -#1446=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_60','Parkour',#1429,$,$); -#1447=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_70','Recreational cycling',#1429,$,$); -#1448=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_71','Recreational walking',#1429,$,$); -#1449=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_72','Riding',#1429,$,$); -#1450=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_74','Running',#1429,$,$); -#1451=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_76','Skateboarding',#1429,$,$); -#1452=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_82','Speedway racing',#1429,$,$); -#1453=IFCCLASSIFICATIONREFERENCE($,'Ac_42_80','Sports ancillary activities',#1414,$,$); -#1454=IFCCLASSIFICATIONREFERENCE($,'Ac_42_80_15','Corporate and VIP spectating',#1453,$,$); -#1455=IFCCLASSIFICATIONREFERENCE($,'Ac_42_80_50','Manager and coach seating',#1453,$,$); -#1456=IFCCLASSIFICATIONREFERENCE($,'Ac_42_80_65','Press spectating',#1453,$,$); -#1457=IFCCLASSIFICATIONREFERENCE($,'Ac_42_80_72','Reserves seating',#1453,$,$); -#1458=IFCCLASSIFICATIONREFERENCE($,'Ac_42_85','Swimming activities',#1414,$,$); -#1459=IFCCLASSIFICATIONREFERENCE($,'Ac_42_85_15','Competition swimming',#1458,$,$); -#1460=IFCCLASSIFICATIONREFERENCE($,'Ac_42_85_22','Diving',#1458,$,$); -#1461=IFCCLASSIFICATIONREFERENCE($,'Ac_42_85_71','Recreational swimming',#1458,$,$); -#1462=IFCCLASSIFICATIONREFERENCE($,'Ac_42_85_80','Spa activities',#1458,$,$); -#1463=IFCCLASSIFICATIONREFERENCE($,'Ac_42_85_92','Underwater observation',#1458,$,$); -#1464=IFCCLASSIFICATIONREFERENCE($,'Ac_42_85_94','Water flume, slide and tube riding',#1458,$,$); -#1465=IFCCLASSIFICATIONREFERENCE($,'Ac_42_85_95','Water polo',#1458,$,$); -#1466=IFCCLASSIFICATIONREFERENCE($,'Ac_42_85_97','Wave riding',#1458,$,$); -#1467=IFCCLASSIFICATIONREFERENCE($,'Ac_42_85_98','Whirlpool bath activities',#1458,$,$); -#1468=IFCCLASSIFICATIONREFERENCE($,'Ac_42_90','Water activities',#1414,$,$); -#1469=IFCCLASSIFICATIONREFERENCE($,'Ac_42_90_11','Canoe slalom',#1468,$,$); -#1470=IFCCLASSIFICATIONREFERENCE($,'Ac_42_90_12','Canoe sprint',#1468,$,$); -#1471=IFCCLASSIFICATIONREFERENCE($,'Ac_42_90_50','Motor boating',#1468,$,$); -#1472=IFCCLASSIFICATIONREFERENCE($,'Ac_42_90_73','Rowing',#1468,$,$); -#1473=IFCCLASSIFICATIONREFERENCE($,'Ac_42_90_75','Sailing',#1468,$,$); -#1474=IFCCLASSIFICATIONREFERENCE($,'Ac_42_90_97','Water skiing',#1468,$,$); -#1475=IFCCLASSIFICATIONREFERENCE($,'Ac_42_90_98','White water canoeing',#1468,$,$); -#1476=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95','Winter sports activities',#1414,$,$); -#1477=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_02','Alpine skiing',#1476,$,$); -#1478=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_08','Bobsleighing',#1476,$,$); -#1479=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_19','Cross-country skiing',#1476,$,$); -#1480=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_20','Curling',#1476,$,$); -#1481=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_32','Freestyle skiing',#1476,$,$); -#1482=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_40','Ice skating',#1476,$,$); -#1483=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_41','Ice hockey',#1476,$,$); -#1484=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_49','Luge',#1476,$,$); -#1485=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_76','Short track speed skating',#1476,$,$); -#1486=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_77','Skeleton sledding',#1476,$,$); -#1487=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_78','Skiing',#1476,$,$); -#1488=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_79','Ski jumping',#1476,$,$); -#1489=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_80','Snowboarding',#1476,$,$); -#1490=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_83','Speed skating',#1476,$,$); -#1491=IFCCLASSIFICATIONREFERENCE($,'Ac_45','Residential activities',#850,$,$); -#1492=IFCCLASSIFICATIONREFERENCE($,'Ac_45_30','External living activities',#1491,$,$); -#1493=IFCCLASSIFICATIONREFERENCE($,'Ac_45_30_11','Camping',#1492,$,$); -#1494=IFCCLASSIFICATIONREFERENCE($,'Ac_45_30_12','Caravanning',#1492,$,$); -#1495=IFCCLASSIFICATIONREFERENCE($,'Ac_45_30_33','Gardening',#1492,$,$); -#1496=IFCCLASSIFICATIONREFERENCE($,'Ac_45_45','Living activities',#1491,$,$); -#1497=IFCCLASSIFICATIONREFERENCE($,'Ac_45_45_14','Communal socializing',#1496,$,$); -#1498=IFCCLASSIFICATIONREFERENCE($,'Ac_45_45_22','Dining',#1496,$,$); -#1499=IFCCLASSIFICATIONREFERENCE($,'Ac_45_45_79','Sleeping',#1496,$,$); -#1500=IFCCLASSIFICATIONREFERENCE($,'Ac_45_70','Residential support activities',#1491,$,$); -#1501=IFCCLASSIFICATIONREFERENCE($,'Ac_45_70_16','Concierge servicing',#1500,$,$); -#1502=IFCCLASSIFICATIONREFERENCE($,'Ac_45_70_93','Utility activities',#1500,$,$); -#1503=IFCCLASSIFICATIONREFERENCE($,'Ac_50','Waste disposal activities',#850,$,$); -#1504=IFCCLASSIFICATIONREFERENCE($,'Ac_50_40','Dry waste collecting',#1503,$,$); -#1505=IFCCLASSIFICATIONREFERENCE($,'Ac_50_40_72','Refuse storing',#1504,$,$); -#1506=IFCCLASSIFICATIONREFERENCE($,'Ac_50_40_78','Scrapping',#1504,$,$); -#1507=IFCCLASSIFICATIONREFERENCE($,'Ac_55','Piped supply activities',#850,$,$); -#1508=IFCCLASSIFICATIONREFERENCE($,'Ac_55_60','Piped supply installations testing',#1507,$,$); -#1509=IFCCLASSIFICATIONREFERENCE($,'Ac_55_60_30','Fire suppression installation testing',#1508,$,$); -#1510=IFCCLASSIFICATIONREFERENCE($,'Ac_55_60_68','Public health installation testing',#1508,$,$); -#1511=IFCCLASSIFICATIONREFERENCE($,'Ac_55_60_96','Water supply installation testing',#1508,$,$); -#1512=IFCCLASSIFICATIONREFERENCE($,'Ac_55_65','Piped supply systems commissioning',#1507,$,$); -#1513=IFCCLASSIFICATIONREFERENCE($,'Ac_55_65_31','Fire suppression systems commissioning',#1512,$,$); -#1514=IFCCLASSIFICATIONREFERENCE($,'Ac_55_65_96','Water supply systems commissioning',#1512,$,$); -#1515=IFCCLASSIFICATIONREFERENCE($,'Ac_60','Heating, cooling and refrigeration activities',#850,$,$); -#1516=IFCCLASSIFICATIONREFERENCE($,'Ac_60_60','Heating and chilled water installations testing',#1515,$,$); -#1517=IFCCLASSIFICATIONREFERENCE($,'Ac_60_60_13','Chilled water installations testing',#1516,$,$); -#1518=IFCCLASSIFICATIONREFERENCE($,'Ac_60_60_36','Heating installations testing',#1516,$,$); -#1519=IFCCLASSIFICATIONREFERENCE($,'Ac_60_60_63','Heating and cooling plant and equipment testing',#1516,$,$); -#1520=IFCCLASSIFICATIONREFERENCE($,'Ac_60_60_65','Pressure testing pipework',#1516,$,$); -#1521=IFCCLASSIFICATIONREFERENCE($,'Ac_60_65','Heating and cooling systems and plant commissioning',#1515,$,$); -#1522=IFCCLASSIFICATIONREFERENCE($,'Ac_60_65_06','Boilers commissioning',#1521,$,$); -#1523=IFCCLASSIFICATIONREFERENCE($,'Ac_60_65_13','Chilled water systems commissioning',#1521,$,$); -#1524=IFCCLASSIFICATIONREFERENCE($,'Ac_60_65_36','Heating systems commissioning',#1521,$,$); -#1525=IFCCLASSIFICATIONREFERENCE($,'Ac_60_65_70','Refrigeration plant and equipment commissioning',#1521,$,$); -#1526=IFCCLASSIFICATIONREFERENCE($,'Ac_65','Ventilation and air conditioning activities',#850,$,$); -#1527=IFCCLASSIFICATIONREFERENCE($,'Ac_65_60','Ventilation and air conditioning installation testing',#1526,$,$); -#1528=IFCCLASSIFICATIONREFERENCE($,'Ac_65_60_01','Air conditioning plant and equipment testing',#1527,$,$); -#1529=IFCCLASSIFICATIONREFERENCE($,'Ac_65_60_02','Air supply installations testing',#1527,$,$); -#1530=IFCCLASSIFICATIONREFERENCE($,'Ac_65_60_63','Ventilation plant and equipment testing',#1527,$,$); -#1531=IFCCLASSIFICATIONREFERENCE($,'Ac_65_65','Ventilation and air conditioning systems commissioning',#1526,$,$); -#1532=IFCCLASSIFICATIONREFERENCE($,'Ac_65_65_02','Air systems commissioning',#1531,$,$); -#1533=IFCCLASSIFICATIONREFERENCE($,'Ac_70','Electrical activities',#850,$,$); -#1534=IFCCLASSIFICATIONREFERENCE($,'Ac_70_60','Electrical installations testing',#1533,$,$); -#1535=IFCCLASSIFICATIONREFERENCE($,'Ac_70_60_28','Emergency lighting installations testing',#1534,$,$); -#1536=IFCCLASSIFICATIONREFERENCE($,'Ac_70_60_37','High voltage electrical installations testing',#1534,$,$); -#1537=IFCCLASSIFICATIONREFERENCE($,'Ac_70_60_46','Lighting installations testing',#1534,$,$); -#1538=IFCCLASSIFICATIONREFERENCE($,'Ac_70_60_47','Lightning protection installations testing',#1534,$,$); -#1539=IFCCLASSIFICATIONREFERENCE($,'Ac_70_60_49','Low voltage electrical installation testing and inspecting',#1534,$,$); -#1540=IFCCLASSIFICATIONREFERENCE($,'Ac_70_65','Electrical systems commissioning',#1533,$,$); -#1541=IFCCLASSIFICATIONREFERENCE($,'Ac_70_65_46','Lighting systems commissioning',#1540,$,$); -#1542=IFCCLASSIFICATIONREFERENCE($,'Ac_75','Communications, security, safety and protection activities',#850,$,$); -#1543=IFCCLASSIFICATIONREFERENCE($,'Ac_75_60','Communications, security, safety and protection installations testing',#1542,$,$); -#1544=IFCCLASSIFICATIONREFERENCE($,'Ac_75_60_01','Access control systems testing',#1543,$,$); -#1545=IFCCLASSIFICATIONREFERENCE($,'Ac_75_60_04','Audio visual systems testing',#1543,$,$); -#1546=IFCCLASSIFICATIONREFERENCE($,'Ac_75_60_15','Control systems testing',#1543,$,$); -#1547=IFCCLASSIFICATIONREFERENCE($,'Ac_75_60_30','Fire protection installation testing',#1543,$,$); -#1548=IFCCLASSIFICATIONREFERENCE($,'Ac_75_60_42','Intruder alarm systems testing',#1543,$,$); -#1549=IFCCLASSIFICATIONREFERENCE($,'Ac_75_60_47','Lifts testing',#1543,$,$); -#1550=IFCCLASSIFICATIONREFERENCE($,'Ac_75_60_80','Security systems testing',#1543,$,$); -#1551=IFCCLASSIFICATIONREFERENCE($,'Ac_75_60_85','Surveillance equipment installations testing',#1543,$,$); -#1552=IFCCLASSIFICATIONREFERENCE($,'Ac_75_60_92','Telecommunications systems testing',#1543,$,$); -#1553=IFCCLASSIFICATIONREFERENCE($,'Ac_75_65','Communications, security, safety and protection systems commissioning',#1542,$,$); -#1554=IFCCLASSIFICATIONREFERENCE($,'Ac_75_65_01','Access control systems commissioning',#1553,$,$); -#1555=IFCCLASSIFICATIONREFERENCE($,'Ac_75_65_04','Audio visual systems commissioning',#1553,$,$); -#1556=IFCCLASSIFICATIONREFERENCE($,'Ac_75_65_15','Control systems commissioning',#1553,$,$); -#1557=IFCCLASSIFICATIONREFERENCE($,'Ac_75_65_30','Fire alarm systems commissioning',#1553,$,$); -#1558=IFCCLASSIFICATIONREFERENCE($,'Ac_75_65_42','Intruder alarm systems commissioning',#1553,$,$); -#1559=IFCCLASSIFICATIONREFERENCE($,'Ac_75_65_47','Lifts commissioning',#1553,$,$); -#1560=IFCCLASSIFICATIONREFERENCE($,'Ac_75_65_80','Security systems commissioning',#1553,$,$); -#1561=IFCCLASSIFICATIONREFERENCE($,'Ac_75_65_85','Surveillance systems commissioning',#1553,$,$); -#1562=IFCCLASSIFICATIONREFERENCE($,'Ac_75_65_92','Telecommunications systems commissioning',#1553,$,$); -#1563=IFCCLASSIFICATIONREFERENCE($,'Ac_80','Transport activities',#850,$,$); -#1564=IFCCLASSIFICATIONREFERENCE($,'Ac_80_00','Accommodation works activities',#1563,$,$); -#1565=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05','Aerospace ground activities',#1563,$,$); -#1566=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_02','Aeroplane landing',#1565,$,$); -#1567=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_03','Aeroplane take-off',#1565,$,$); -#1568=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_05','Aircraft manoeuvring',#1565,$,$); -#1569=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_06','Aircraft manoeuvring buffering',#1565,$,$); -#1570=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_07','Aircraft standing',#1565,$,$); -#1571=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_09','Airport controlling',#1565,$,$); -#1572=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_33','Glider landing',#1565,$,$); -#1573=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_34','Glider take-off',#1565,$,$); -#1574=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_36','Hang gliding landing',#1565,$,$); -#1575=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_37','Hang gliding take-off',#1565,$,$); -#1576=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_38','Helicopter landing',#1565,$,$); -#1577=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_39','Helicopter take-off',#1565,$,$); -#1578=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_82','Spacecraft landing',#1565,$,$); -#1579=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_84','Spacecraft take-off',#1565,$,$); -#1580=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10','Loading and embarkation activities',#1563,$,$); -#1581=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_04','Aircraft fuelling',#1580,$,$); -#1582=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_06','Baggage claiming',#1580,$,$); -#1583=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_07','Baggage handling',#1580,$,$); -#1584=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_08','Baggage loading',#1580,$,$); -#1585=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_12','Cargo handling',#1580,$,$); -#1586=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_13','Cargo loading',#1580,$,$); -#1587=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_20','Customs controlling',#1580,$,$); -#1588=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_60','Passenger arriving',#1580,$,$); -#1589=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_61','Passenger departing',#1580,$,$); -#1590=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_62','Passenger disembarking',#1580,$,$); -#1591=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_63','Passenger embarking',#1580,$,$); -#1592=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_64','Passenger gathering',#1580,$,$); -#1593=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_65','Passport controlling',#1580,$,$); -#1594=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_86','Ticketing',#1580,$,$); -#1595=IFCCLASSIFICATIONREFERENCE($,'Ac_80_15','Aerospace maintenance activities',#1563,$,$); -#1596=IFCCLASSIFICATIONREFERENCE($,'Ac_80_15_01','Aircraft cleaning',#1595,$,$); -#1597=IFCCLASSIFICATIONREFERENCE($,'Ac_80_15_02','Aircraft maintaining',#1595,$,$); -#1598=IFCCLASSIFICATIONREFERENCE($,'Ac_80_15_04','Aircraft repairing',#1595,$,$); -#1599=IFCCLASSIFICATIONREFERENCE($,'Ac_80_15_79','Spacecraft cleaning',#1595,$,$); -#1600=IFCCLASSIFICATIONREFERENCE($,'Ac_80_15_80','Spacecraft maintaining',#1595,$,$); -#1601=IFCCLASSIFICATIONREFERENCE($,'Ac_80_15_81','Spacecraft preparing',#1595,$,$); -#1602=IFCCLASSIFICATIONREFERENCE($,'Ac_80_15_82','Spacecraft repairing',#1595,$,$); -#1603=IFCCLASSIFICATIONREFERENCE($,'Ac_80_20','Cable way activities',#1563,$,$); -#1604=IFCCLASSIFICATIONREFERENCE($,'Ac_80_20_13','Cableway travelling',#1603,$,$); -#1605=IFCCLASSIFICATIONREFERENCE($,'Ac_80_30','Cable transport storage and maintenance activities',#1563,$,$); -#1606=IFCCLASSIFICATIONREFERENCE($,'Ac_80_30_34','Gondola repair and cleaning',#1605,$,$); -#1607=IFCCLASSIFICATIONREFERENCE($,'Ac_80_30_35','Gondola storing',#1605,$,$); -#1608=IFCCLASSIFICATIONREFERENCE($,'Ac_80_35','Highway activities',#1563,$,$); -#1609=IFCCLASSIFICATIONREFERENCE($,'Ac_80_35_08','Bus manoeuvring',#1608,$,$); -#1610=IFCCLASSIFICATIONREFERENCE($,'Ac_80_35_12','Car manoeuvring',#1608,$,$); -#1611=IFCCLASSIFICATIONREFERENCE($,'Ac_80_35_16','Carriageway separating',#1608,$,$); -#1612=IFCCLASSIFICATIONREFERENCE($,'Ac_80_35_24','Driving',#1608,$,$); -#1613=IFCCLASSIFICATIONREFERENCE($,'Ac_80_35_46','Laying-by and passing',#1608,$,$); -#1614=IFCCLASSIFICATIONREFERENCE($,'Ac_80_35_63','Pedestrian crossing',#1608,$,$); -#1615=IFCCLASSIFICATIONREFERENCE($,'Ac_80_35_64','Pedestrian standing',#1608,$,$); -#1616=IFCCLASSIFICATIONREFERENCE($,'Ac_80_35_70','Railway crossing',#1608,$,$); -#1617=IFCCLASSIFICATIONREFERENCE($,'Ac_80_35_73','Road buffering',#1608,$,$); -#1618=IFCCLASSIFICATIONREFERENCE($,'Ac_80_35_90','Truck manoeuvring',#1608,$,$); -#1619=IFCCLASSIFICATIONREFERENCE($,'Ac_80_35_95','Vehicle manoeuvring',#1608,$,$); -#1620=IFCCLASSIFICATIONREFERENCE($,'Ac_80_45','Highway storage and maintenance activities',#1563,$,$); -#1621=IFCCLASSIFICATIONREFERENCE($,'Ac_80_45_09','Bus standing',#1620,$,$); -#1622=IFCCLASSIFICATIONREFERENCE($,'Ac_80_45_40','Indoor vehicle parking',#1620,$,$); -#1623=IFCCLASSIFICATIONREFERENCE($,'Ac_80_45_59','Outdoor vehicle parking',#1620,$,$); -#1624=IFCCLASSIFICATIONREFERENCE($,'Ac_80_45_91','Truck standing',#1620,$,$); -#1625=IFCCLASSIFICATIONREFERENCE($,'Ac_80_45_94','Vehicle fuelling and charging',#1620,$,$); -#1626=IFCCLASSIFICATIONREFERENCE($,'Ac_80_45_95','Vehicle inspecting',#1620,$,$); -#1627=IFCCLASSIFICATIONREFERENCE($,'Ac_80_45_96','Vehicle servicing',#1620,$,$); -#1628=IFCCLASSIFICATIONREFERENCE($,'Ac_80_50','Railway activities',#1563,$,$); -#1629=IFCCLASSIFICATIONREFERENCE($,'Ac_80_50_50','Marshalling',#1628,$,$); -#1630=IFCCLASSIFICATIONREFERENCE($,'Ac_80_50_70','Rail over passing',#1628,$,$); -#1631=IFCCLASSIFICATIONREFERENCE($,'Ac_80_50_71','Rail signal controlling',#1628,$,$); -#1632=IFCCLASSIFICATIONREFERENCE($,'Ac_80_50_73','Railway track buffering',#1628,$,$); -#1633=IFCCLASSIFICATIONREFERENCE($,'Ac_80_50_75','Railway travel',#1628,$,$); -#1634=IFCCLASSIFICATIONREFERENCE($,'Ac_80_50_76','Rail under passing',#1628,$,$); -#1635=IFCCLASSIFICATIONREFERENCE($,'Ac_80_50_90','Train stopping',#1628,$,$); -#1636=IFCCLASSIFICATIONREFERENCE($,'Ac_80_60','Rail storage and maintenance activities',#1563,$,$); -#1637=IFCCLASSIFICATIONREFERENCE($,'Ac_80_60_11','Carriage cleaning',#1636,$,$); -#1638=IFCCLASSIFICATIONREFERENCE($,'Ac_80_60_26','Engine fuelling',#1636,$,$); -#1639=IFCCLASSIFICATIONREFERENCE($,'Ac_80_60_27','Engine inspecting',#1636,$,$); -#1640=IFCCLASSIFICATIONREFERENCE($,'Ac_80_60_28','Engine servicing',#1636,$,$); -#1641=IFCCLASSIFICATIONREFERENCE($,'Ac_80_60_29','Engine washing',#1636,$,$); -#1642=IFCCLASSIFICATIONREFERENCE($,'Ac_80_60_70','Rail repairing',#1636,$,$); -#1643=IFCCLASSIFICATIONREFERENCE($,'Ac_80_70','Marine way and waterway activities',#1563,$,$); -#1644=IFCCLASSIFICATIONREFERENCE($,'Ac_80_70_11','Canal level changing',#1643,$,$); -#1645=IFCCLASSIFICATIONREFERENCE($,'Ac_80_70_12','Canal travelling',#1643,$,$); -#1646=IFCCLASSIFICATIONREFERENCE($,'Ac_80_70_37','Harbour level changing',#1643,$,$); -#1647=IFCCLASSIFICATIONREFERENCE($,'Ac_80_94','Bridge function',#1563,$,$); -#1648=IFCCLASSIFICATIONREFERENCE($,'Ac_80_94_41','Bridge inspecting',#1647,$,$); -#1649=IFCCLASSIFICATIONREFERENCE($,'Ac_80_94_60','Passing over a bridge',#1647,$,$); -#1650=IFCCLASSIFICATIONREFERENCE($,'Ac_80_94_90','Passing under a bridge',#1647,$,$); -#1651=IFCCLASSIFICATIONREFERENCE($,'Ac_85','Operation and maintenance activities',#850,$,$); -#1652=IFCCLASSIFICATIONREFERENCE($,'Ac_85_10','Barrier and fence maintenance activities',#1651,$,$); -#1653=IFCCLASSIFICATIONREFERENCE($,'Ac_85_10_06','Barrier maintenance',#1652,$,$); -#1654=IFCCLASSIFICATIONREFERENCE($,'Ac_85_10_30','Fencing maintenance',#1652,$,$); -#1655=IFCCLASSIFICATIONREFERENCE($,'Ac_85_10_45','Kerbs and channels maintenance',#1652,$,$); -#1656=IFCCLASSIFICATIONREFERENCE($,'Ac_85_10_95','Vehicle restraint systems maintenance',#1652,$,$); -#1657=IFCCLASSIFICATIONREFERENCE($,'Ac_85_30','Flora maintenance activities',#1651,$,$); -#1658=IFCCLASSIFICATIONREFERENCE($,'Ac_85_30_01','Amenity grass maintenance',#1657,$,$); -#1659=IFCCLASSIFICATIONREFERENCE($,'Ac_85_30_02','Amenity planting maintenance',#1657,$,$); -#1660=IFCCLASSIFICATIONREFERENCE($,'Ac_85_30_04','Aquatic and wetland planting maintenance',#1657,$,$); -#1661=IFCCLASSIFICATIONREFERENCE($,'Ac_85_30_28','External container planting maintenance',#1657,$,$); -#1662=IFCCLASSIFICATIONREFERENCE($,'Ac_85_30_30','Forestry maintenance',#1657,$,$); -#1663=IFCCLASSIFICATIONREFERENCE($,'Ac_85_30_37','Hedgerow maintenance',#1657,$,$); -#1664=IFCCLASSIFICATIONREFERENCE($,'Ac_85_30_40','Internal container planting maintenance',#1657,$,$); -#1665=IFCCLASSIFICATIONREFERENCE($,'Ac_85_30_47','Living roof maintenance',#1657,$,$); -#1666=IFCCLASSIFICATIONREFERENCE($,'Ac_85_30_50','Meadow grass maintenance',#1657,$,$); -#1667=IFCCLASSIFICATIONREFERENCE($,'Ac_85_30_80','Sports turf maintenance',#1657,$,$); -#1668=IFCCLASSIFICATIONREFERENCE($,'Ac_85_30_95','Vegetation control maintenance',#1657,$,$); -#1669=IFCCLASSIFICATIONREFERENCE($,'Ac_85_30_97','Wildflowers meadow maintenance',#1657,$,$); -#1670=IFCCLASSIFICATIONREFERENCE($,'Ac_85_50','Marine maintenance activities',#1651,$,$); -#1671=IFCCLASSIFICATIONREFERENCE($,'Ac_85_50_24','Dredging',#1670,$,$); -#1672=IFCCLASSIFICATIONREFERENCE($,'Ac_85_60','Paving maintenance activities',#1651,$,$); -#1673=IFCCLASSIFICATIONREFERENCE($,'Ac_85_60_02','Asphalt paving maintenance',#1672,$,$); -#1674=IFCCLASSIFICATIONREFERENCE($,'Ac_85_60_04','Asphalt sports paving maintenance',#1672,$,$); -#1675=IFCCLASSIFICATIONREFERENCE($,'Ac_85_60_10','Bound aggregate paving maintenance',#1672,$,$); -#1676=IFCCLASSIFICATIONREFERENCE($,'Ac_85_60_50','Mat and sheet paving maintenance',#1672,$,$); -#1677=IFCCLASSIFICATIONREFERENCE($,'Ac_85_60_80','Sport or play paving maintenance',#1672,$,$); -#1678=IFCCLASSIFICATIONREFERENCE($,'Ac_85_60_82','Sports or play unbound paving maintenance',#1672,$,$); -#1679=IFCCLASSIFICATIONREFERENCE($,'Ac_85_60_92','Unbound paving maintenance',#1672,$,$); -#1680=IFCCLASSIFICATIONREFERENCE($,'Ac_85_60_93','Unit paving maintenance',#1672,$,$); -#1681=IFCCLASSIFICATIONREFERENCE($,'Ac_85_65','Plant and controls operating',#1651,$,$); -#1682=IFCCLASSIFICATIONREFERENCE($,'Ac_85_65_08','Boiler operating',#1681,$,$); -#1683=IFCCLASSIFICATIONREFERENCE($,'Ac_85_65_15','Controlling',#1681,$,$); -#1684=IFCCLASSIFICATIONREFERENCE($,'Ac_85_65_26','Electrical switching',#1681,$,$); -#1685=IFCCLASSIFICATIONREFERENCE($,'Ac_85_65_27','Equipment operating',#1681,$,$); -#1686=IFCCLASSIFICATIONREFERENCE($,'Ac_85_65_32','Furnace operating',#1681,$,$); -#1687=IFCCLASSIFICATIONREFERENCE($,'Ac_85_65_42','Incinerating',#1681,$,$); -#1688=IFCCLASSIFICATIONREFERENCE($,'Ac_85_65_48','Lift machine operating',#1681,$,$); -#1689=IFCCLASSIFICATIONREFERENCE($,'Ac_85_65_50','Meter checking',#1681,$,$); -#1690=IFCCLASSIFICATIONREFERENCE($,'Ac_85_65_64','Plant operating',#1681,$,$); -#1691=IFCCLASSIFICATIONREFERENCE($,'Ac_85_65_77','Server operating',#1681,$,$); -#1692=IFCCLASSIFICATIONREFERENCE($,'Ac_85_65_90','Transformer operating',#1681,$,$); -#1693=IFCCLASSIFICATIONREFERENCE($,'Ac_85_70','Retrospective application activities',#1651,$,$); -#1694=IFCCLASSIFICATIONREFERENCE($,'Ac_85_70_40','Insulating and waterproofing retrofitted living roofs',#1693,$,$); -#1695=IFCCLASSIFICATIONREFERENCE($,'Ac_85_70_70','Retrospective applying of fire retardant treatment',#1693,$,$); -#1696=IFCCLASSIFICATIONREFERENCE($,'Ac_85_70_75','Retrospective applying of preservative treatment',#1693,$,$); -#1697=IFCCLASSIFICATIONREFERENCE($,'Ac_90','Circulation and plant activities',#850,$,$); -#1698=IFCCLASSIFICATIONREFERENCE($,'Ac_90_10','Circulation activities',#1697,$,$); -#1699=IFCCLASSIFICATIONREFERENCE($,'Ac_90_10_02','Air blocking',#1698,$,$); -#1700=IFCCLASSIFICATIONREFERENCE($,'Ac_90_10_14','Circulating between rooms',#1698,$,$); -#1701=IFCCLASSIFICATIONREFERENCE($,'Ac_90_10_16','Covered walking',#1698,$,$); -#1702=IFCCLASSIFICATIONREFERENCE($,'Ac_90_10_24','Dropping-off and collecting',#1698,$,$); -#1703=IFCCLASSIFICATIONREFERENCE($,'Ac_90_10_27','Entering and exiting',#1698,$,$); -#1704=IFCCLASSIFICATIONREFERENCE($,'Ac_90_10_34','Goods conveying',#1698,$,$); -#1705=IFCCLASSIFICATIONREFERENCE($,'Ac_90_10_49','Lift stopping and calling',#1698,$,$); -#1706=IFCCLASSIFICATIONREFERENCE($,'Ac_90_10_50','Lift travelling',#1698,$,$); -#1707=IFCCLASSIFICATIONREFERENCE($,'Ac_90_10_77','Sheltering',#1698,$,$); -#1708=IFCCLASSIFICATIONREFERENCE($,'Ac_90_10_78','Shoppers moving and circulation',#1698,$,$); -#1709=IFCCLASSIFICATIONREFERENCE($,'Ac_90_10_93','Uncovered walking',#1698,$,$); -#1710=IFCCLASSIFICATIONREFERENCE($,'Ac_90_10_96','Wheelchair travelling',#1698,$,$); -#1711=IFCCLASSIFICATIONREFERENCE($,'Ac_90_20','Common activities',#1697,$,$); -#1712=IFCCLASSIFICATIONREFERENCE($,'Ac_90_20_09','Briefing',#1711,$,$); -#1713=IFCCLASSIFICATIONREFERENCE($,'Ac_90_20_13','Changing',#1711,$,$); -#1714=IFCCLASSIFICATIONREFERENCE($,'Ac_90_20_42','Interviewing',#1711,$,$); -#1715=IFCCLASSIFICATIONREFERENCE($,'Ac_90_20_69','Queuing',#1711,$,$); -#1716=IFCCLASSIFICATIONREFERENCE($,'Ac_90_20_72','Resting',#1711,$,$); -#1717=IFCCLASSIFICATIONREFERENCE($,'Ac_90_20_82','Spectator seating',#1711,$,$); -#1718=IFCCLASSIFICATIONREFERENCE($,'Ac_90_20_83','Spectator standing',#1711,$,$); -#1719=IFCCLASSIFICATIONREFERENCE($,'Ac_90_20_96','Waiting',#1711,$,$); -#1720=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50','Storing activities',#1697,$,$); -#1721=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_02','Aircraft storing',#1720,$,$); -#1722=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_04','Arms storing',#1720,$,$); -#1723=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_06','Baggage storing',#1720,$,$); -#1724=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_07','Beer storing',#1720,$,$); -#1725=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_09','Blood storing',#1720,$,$); -#1726=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_10','Boat storing',#1720,$,$); -#1727=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_11','Cargo storing',#1720,$,$); -#1728=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_13','Chemicals storing',#1720,$,$); -#1729=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_14','Clothes storing',#1720,$,$); -#1730=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_15','Cold storing',#1720,$,$); -#1731=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_24','Dry waste storing',#1720,$,$); -#1732=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_25','Evidence storing',#1720,$,$); -#1733=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_26','Explosives storing',#1720,$,$); -#1734=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_28','Feed storing',#1720,$,$); -#1735=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_29','Flammable chemicals storing',#1720,$,$); -#1736=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_30','Food storing',#1720,$,$); -#1737=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_32','Fuel storing',#1720,$,$); -#1738=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_34','Gas storing',#1720,$,$); -#1739=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_35','General storing',#1720,$,$); -#1740=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_36','Glider storing',#1720,$,$); -#1741=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_37','Goods storing',#1720,$,$); -#1742=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_39','Grain storing',#1720,$,$); -#1743=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_41','Hang glider storing',#1720,$,$); -#1744=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_42','Hazardous waste storing',#1720,$,$); -#1745=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_44','Helicoptor storing',#1720,$,$); -#1746=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_47','Left luggage storing',#1720,$,$); -#1747=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_52','Medical records storing',#1720,$,$); -#1748=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_53','Mineral storing',#1720,$,$); -#1749=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_58','Oil storing',#1720,$,$); -#1750=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_59','Outdoor storing',#1720,$,$); -#1751=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_65','Pharmacy storing',#1720,$,$); -#1752=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_70','Raw materials storing',#1720,$,$); -#1753=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_75','Scientific equipment storing',#1720,$,$); -#1754=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_77','Secure storing',#1720,$,$); -#1755=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_80','Solid fuel storing',#1720,$,$); -#1756=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_84','Storage of human remains',#1720,$,$); -#1757=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_91','Vehicle storing',#1720,$,$); -#1758=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_92','Walk-in clothes storing',#1720,$,$); -#1759=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_93','Waste gas storing',#1720,$,$); -#1760=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_94','Waste liquids storing',#1720,$,$); -#1761=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_95','Waste solids storing',#1720,$,$); -#1762=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_96','Water storing',#1720,$,$); -#1763=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_97','Wet waste storing',#1720,$,$); -#1764=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_98','Wine storing',#1720,$,$); -#1765=IFCCLASSIFICATIONREFERENCE($,'SL','Spaces/ locations',#1,$,$); -#1766=IFCCLASSIFICATIONREFERENCE($,'SL_20','Administrative, commercial and protective service spaces',#1765,$,$); -#1767=IFCCLASSIFICATIONREFERENCE($,'SL_20_10','Legislative spaces',#1766,$,$); -#1768=IFCCLASSIFICATIONREFERENCE($,'SL_20_10_47','Legislative chambers',#1767,$,$); -#1769=IFCCLASSIFICATIONREFERENCE($,'SL_20_10_49','Legislative chamber viewing galleries',#1767,$,$); -#1770=IFCCLASSIFICATIONREFERENCE($,'SL_20_15','Administrative spaces',#1766,$,$); -#1771=IFCCLASSIFICATIONREFERENCE($,'SL_20_15_27','Enclosed offices',#1770,$,$); -#1772=IFCCLASSIFICATIONREFERENCE($,'SL_20_15_50','Meeting rooms',#1770,$,$); -#1773=IFCCLASSIFICATIONREFERENCE($,'SL_20_15_59','Offices',#1770,$,$); -#1774=IFCCLASSIFICATIONREFERENCE($,'SL_20_15_61','Open-plan offices',#1770,$,$); -#1775=IFCCLASSIFICATIONREFERENCE($,'SL_20_15_71','Reception areas',#1770,$,$); -#1776=IFCCLASSIFICATIONREFERENCE($,'SL_20_45','Motor vehicle maintenance and fuelling spaces',#1766,$,$); -#1777=IFCCLASSIFICATIONREFERENCE($,'SL_20_45_27','Electric motor vehicle charging points',#1776,$,$); -#1778=IFCCLASSIFICATIONREFERENCE($,'SL_20_45_29','Fuel filling station air and water points',#1776,$,$); -#1779=IFCCLASSIFICATIONREFERENCE($,'SL_20_45_30','Fuel filling station forecourts',#1776,$,$); -#1780=IFCCLASSIFICATIONREFERENCE($,'SL_20_45_31','Fuel filling station tanks areas',#1776,$,$); -#1781=IFCCLASSIFICATIONREFERENCE($,'SL_20_45_53','Motor vehicle maintenance areas',#1776,$,$); -#1782=IFCCLASSIFICATIONREFERENCE($,'SL_20_45_95','Vehicle inspection pits',#1776,$,$); -#1783=IFCCLASSIFICATIONREFERENCE($,'SL_20_45_96','Vehicle servicing areas',#1776,$,$); -#1784=IFCCLASSIFICATIONREFERENCE($,'SL_20_50','Commercial spaces',#1766,$,$); -#1785=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_03','Ambient wholesale spaces',#1784,$,$); -#1786=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_05','Auction rooms',#1784,$,$); -#1787=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_10','Beauty salons',#1784,$,$); -#1788=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_12','Checkout points',#1784,$,$); -#1789=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_22','Department store shop floors',#1784,$,$); -#1790=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_29','Financial and professional services outlets',#1784,$,$); -#1791=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_30','Fitting rooms',#1784,$,$); -#1792=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_32','Food and drink outlets',#1784,$,$); -#1793=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_36','Hair and beauty salons',#1784,$,$); -#1794=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_37','Hair salons',#1784,$,$); -#1795=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_47','Livestock auction rooms',#1784,$,$); -#1796=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_51','Market stalls',#1784,$,$); -#1797=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_55','Motor vehicle showrooms',#1784,$,$); -#1798=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_70','Refrigerated wholesale spaces',#1784,$,$); -#1799=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_72','Retail kiosks',#1784,$,$); -#1800=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_85','Supermarket shop floors',#1784,$,$); -#1801=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_86','Tan spray booths',#1784,$,$); -#1802=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_87','Tattoo and piercing parlours',#1784,$,$); -#1803=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_96','Waste and scrap yards',#1784,$,$); -#1804=IFCCLASSIFICATIONREFERENCE($,'SL_20_55','Postal communications spaces',#1766,$,$); -#1805=IFCCLASSIFICATIONREFERENCE($,'SL_20_55_45','Letter sorting offices',#1804,$,$); -#1806=IFCCLASSIFICATIONREFERENCE($,'SL_20_55_50','Mail order sorting and despatch facilities',#1804,$,$); -#1807=IFCCLASSIFICATIONREFERENCE($,'SL_20_55_60','Parcel sorting offices',#1804,$,$); -#1808=IFCCLASSIFICATIONREFERENCE($,'SL_20_55_65','Post rooms',#1804,$,$); -#1809=IFCCLASSIFICATIONREFERENCE($,'SL_20_60','Military protective spaces',#1766,$,$); -#1810=IFCCLASSIFICATIONREFERENCE($,'SL_20_60_08','Bombardment shelters',#1809,$,$); -#1811=IFCCLASSIFICATIONREFERENCE($,'SL_20_60_27','Emergency shelters',#1809,$,$); -#1812=IFCCLASSIFICATIONREFERENCE($,'SL_20_60_70','Radiation protection shelters',#1809,$,$); -#1813=IFCCLASSIFICATIONREFERENCE($,'SL_20_60_98','War emergency centres',#1809,$,$); -#1814=IFCCLASSIFICATIONREFERENCE($,'SL_20_62','Parade spaces',#1766,$,$); -#1815=IFCCLASSIFICATIONREFERENCE($,'SL_20_62_65','Parade grounds',#1814,$,$); -#1816=IFCCLASSIFICATIONREFERENCE($,'SL_20_65','Law enforcement spaces',#1766,$,$); -#1817=IFCCLASSIFICATIONREFERENCE($,'SL_20_65_15','Command and control spaces',#1816,$,$); -#1818=IFCCLASSIFICATIONREFERENCE($,'SL_20_65_28','Examination rooms',#1816,$,$); -#1819=IFCCLASSIFICATIONREFERENCE($,'SL_20_65_39','Identification control rooms',#1816,$,$); -#1820=IFCCLASSIFICATIONREFERENCE($,'SL_20_65_40','Identification suites',#1816,$,$); -#1821=IFCCLASSIFICATIONREFERENCE($,'SL_20_65_41','Interview monitoring rooms',#1816,$,$); -#1822=IFCCLASSIFICATIONREFERENCE($,'SL_20_65_42','Interview rooms',#1816,$,$); -#1823=IFCCLASSIFICATIONREFERENCE($,'SL_20_65_65','Police boxes',#1816,$,$); -#1824=IFCCLASSIFICATIONREFERENCE($,'SL_20_70','Judicial spaces',#1766,$,$); -#1825=IFCCLASSIFICATIONREFERENCE($,'SL_20_70_15','Court rooms',#1824,$,$); -#1826=IFCCLASSIFICATIONREFERENCE($,'SL_20_70_18','Court room viewing galleries',#1824,$,$); -#1827=IFCCLASSIFICATIONREFERENCE($,'SL_20_70_23','Defendant docks',#1824,$,$); -#1828=IFCCLASSIFICATIONREFERENCE($,'SL_20_70_28','Evidence rooms',#1824,$,$); -#1829=IFCCLASSIFICATIONREFERENCE($,'SL_20_70_41','Judicial benches',#1824,$,$); -#1830=IFCCLASSIFICATIONREFERENCE($,'SL_20_70_44','Jury boxes',#1824,$,$); -#1831=IFCCLASSIFICATIONREFERENCE($,'SL_20_70_97','Witness stands',#1824,$,$); -#1832=IFCCLASSIFICATIONREFERENCE($,'SL_20_75','Detention spaces',#1766,$,$); -#1833=IFCCLASSIFICATIONREFERENCE($,'SL_20_75_13','Charge areas',#1832,$,$); -#1834=IFCCLASSIFICATIONREFERENCE($,'SL_20_75_15','Communal inmate dayrooms',#1832,$,$); -#1835=IFCCLASSIFICATIONREFERENCE($,'SL_20_75_22','Detention cells',#1832,$,$); -#1836=IFCCLASSIFICATIONREFERENCE($,'SL_20_75_28','Exercise yards',#1832,$,$); -#1837=IFCCLASSIFICATIONREFERENCE($,'SL_20_75_35','Guard stations',#1832,$,$); -#1838=IFCCLASSIFICATIONREFERENCE($,'SL_20_75_38','Holding cells',#1832,$,$); -#1839=IFCCLASSIFICATIONREFERENCE($,'SL_20_75_75','Sally ports',#1832,$,$); -#1840=IFCCLASSIFICATIONREFERENCE($,'SL_20_75_77','Secure visiting rooms',#1832,$,$); -#1841=IFCCLASSIFICATIONREFERENCE($,'SL_20_75_95','Vehicle impound yards',#1832,$,$); -#1842=IFCCLASSIFICATIONREFERENCE($,'SL_20_80','Weapons training spaces',#1766,$,$); -#1843=IFCCLASSIFICATIONREFERENCE($,'SL_20_80_03','Artillery firing ranges',#1842,$,$); -#1844=IFCCLASSIFICATIONREFERENCE($,'SL_20_80_30','Firing ranges',#1842,$,$); -#1845=IFCCLASSIFICATIONREFERENCE($,'SL_20_80_63','Pistol firing ranges',#1842,$,$); -#1846=IFCCLASSIFICATIONREFERENCE($,'SL_20_80_72','Rifle firing ranges',#1842,$,$); -#1847=IFCCLASSIFICATIONREFERENCE($,'SL_20_85','Security spaces',#1766,$,$); -#1848=IFCCLASSIFICATIONREFERENCE($,'SL_20_85_63','Pedestrian security check points',#1847,$,$); -#1849=IFCCLASSIFICATIONREFERENCE($,'SL_20_85_75','Security control spaces',#1847,$,$); -#1850=IFCCLASSIFICATIONREFERENCE($,'SL_20_85_80','Security offices',#1847,$,$); -#1851=IFCCLASSIFICATIONREFERENCE($,'SL_20_85_95','Vehicular security check points',#1847,$,$); -#1852=IFCCLASSIFICATIONREFERENCE($,'SL_20_90','Fire and incident support spaces',#1766,$,$); -#1853=IFCCLASSIFICATIONREFERENCE($,'SL_20_90_25','Escape stairs',#1852,$,$); -#1854=IFCCLASSIFICATIONREFERENCE($,'SL_20_90_28','Firefighting stairs',#1852,$,$); -#1855=IFCCLASSIFICATIONREFERENCE($,'SL_20_90_30','Fire refuge spaces',#1852,$,$); -#1856=IFCCLASSIFICATIONREFERENCE($,'SL_20_90_31','Fire training spaces',#1852,$,$); -#1857=IFCCLASSIFICATIONREFERENCE($,'SL_20_90_60','Protected escape corridors',#1852,$,$); -#1858=IFCCLASSIFICATIONREFERENCE($,'SL_20_95','Protected zones',#1766,$,$); -#1859=IFCCLASSIFICATIONREFERENCE($,'SL_20_95_20','Detection zones',#1858,$,$); -#1860=IFCCLASSIFICATIONREFERENCE($,'SL_20_95_28','Evacuation zones',#1858,$,$); -#1861=IFCCLASSIFICATIONREFERENCE($,'SL_20_95_30','Fire compartments',#1858,$,$); -#1862=IFCCLASSIFICATIONREFERENCE($,'SL_20_95_32','Fire suppression zones',#1858,$,$); -#1863=IFCCLASSIFICATIONREFERENCE($,'SL_20_95_80','Smoke control zones',#1858,$,$); -#1864=IFCCLASSIFICATIONREFERENCE($,'SL_25','Cultural, educational, scientific and information spaces',#1765,$,$); -#1865=IFCCLASSIFICATIONREFERENCE($,'SL_25_05','Commemoration spaces',#1864,$,$); -#1866=IFCCLASSIFICATIONREFERENCE($,'SL_25_05_72','Commemoration sites',#1865,$,$); -#1867=IFCCLASSIFICATIONREFERENCE($,'SL_25_10','Educational spaces',#1864,$,$); -#1868=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_04','Art classrooms',#1867,$,$); -#1869=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_05','Assembly halls',#1867,$,$); -#1870=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_08','Biology teaching laboratories',#1867,$,$); -#1871=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_13','Chemistry teaching laboratories',#1867,$,$); -#1872=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_14','Classrooms',#1867,$,$); -#1873=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_15','Common rooms',#1867,$,$); -#1874=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_17','Craft classrooms',#1867,$,$); -#1875=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_21','Dance studios',#1867,$,$); -#1876=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_22','Dissection theatres',#1867,$,$); -#1877=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_24','Drama studios',#1867,$,$); -#1878=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_25','Driving skid pans',#1867,$,$); -#1879=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_26','Driving tuition spaces',#1867,$,$); -#1880=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_28','Educational workshops',#1867,$,$); -#1881=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_30','Food technology classrooms',#1867,$,$); -#1882=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_40','Information and communications technology (ICT) laboratories',#1867,$,$); -#1883=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_46','Language laboratories',#1867,$,$); -#1884=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_47','Lecture theatres',#1867,$,$); -#1885=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_55','Music classrooms',#1867,$,$); -#1886=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_66','Physics teaching laboratories',#1867,$,$); -#1887=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_78','Seminar rooms',#1867,$,$); -#1888=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_84','Study rooms',#1867,$,$); -#1889=IFCCLASSIFICATIONREFERENCE($,'SL_25_20','Design spaces',#1864,$,$); -#1890=IFCCLASSIFICATIONREFERENCE($,'SL_25_20_04','Artists'' studios',#1889,$,$); -#1891=IFCCLASSIFICATIONREFERENCE($,'SL_25_20_18','Creative art studios',#1889,$,$); -#1892=IFCCLASSIFICATIONREFERENCE($,'SL_25_20_23','Designers'' studios',#1889,$,$); -#1893=IFCCLASSIFICATIONREFERENCE($,'SL_25_30','Scientific and laboratory spaces',#1864,$,$); -#1894=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_02','Anechoic chambers',#1893,$,$); -#1895=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_04','Astronomical observatories',#1893,$,$); -#1896=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_05','Autoclave rooms',#1893,$,$); -#1897=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_07','Biological laboratories',#1893,$,$); -#1898=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_10','Bioscience laboratories',#1893,$,$); -#1899=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_13','Chemistry laboratories',#1893,$,$); -#1900=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_14','Clean rooms',#1893,$,$); -#1901=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_15','Clinical biochemistry laboratories',#1893,$,$); -#1902=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_16','Clinical microbiology laboratories',#1893,$,$); -#1903=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_17','Clinical pathology laboratories',#1893,$,$); -#1904=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_19','Containment laboratories',#1893,$,$); -#1905=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_21','Dark rooms',#1893,$,$); -#1906=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_22','Dental laboratories',#1893,$,$); -#1907=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_23','Dissection rooms',#1893,$,$); -#1908=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_26','Earth sciences laboratories',#1893,$,$); -#1909=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_27','Engineering laboratories',#1893,$,$); -#1910=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_28','Experiment control rooms',#1893,$,$); -#1911=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_29','Flow cytometry rooms',#1893,$,$); -#1912=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_30','Food testing laboratories',#1893,$,$); -#1913=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_31','Forensics laboratories',#1893,$,$); -#1914=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_32','Forensic scientific support rooms',#1893,$,$); -#1915=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_33','Geology laboratories',#1893,$,$); -#1916=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_42','Instrument rooms',#1893,$,$); -#1917=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_46','Laboratory cold rooms',#1893,$,$); -#1918=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_47','Laboratory warm rooms',#1893,$,$); -#1919=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_50','Material testing laboratories',#1893,$,$); -#1920=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_66','Physics laboratories',#1893,$,$); -#1921=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_68','Psychology laboratories',#1893,$,$); -#1922=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_70','Radiation shielded rooms',#1893,$,$); -#1923=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_76','Scientific equipment rooms',#1893,$,$); -#1924=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_78','Seismograph rooms',#1893,$,$); -#1925=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_88','Testing rooms',#1893,$,$); -#1926=IFCCLASSIFICATIONREFERENCE($,'SL_25_50','Exhibition spaces',#1864,$,$); -#1927=IFCCLASSIFICATIONREFERENCE($,'SL_25_50_15','Collection exhibition spaces',#1926,$,$); -#1928=IFCCLASSIFICATIONREFERENCE($,'SL_25_50_16','Conservation rooms',#1926,$,$); -#1929=IFCCLASSIFICATIONREFERENCE($,'SL_25_50_21','Diorama rooms',#1926,$,$); -#1930=IFCCLASSIFICATIONREFERENCE($,'SL_25_50_26','External galleries',#1926,$,$); -#1931=IFCCLASSIFICATIONREFERENCE($,'SL_25_50_29','Fauna exhibition spaces',#1926,$,$); -#1932=IFCCLASSIFICATIONREFERENCE($,'SL_25_50_31','Flora exhibition spaces',#1926,$,$); -#1933=IFCCLASSIFICATIONREFERENCE($,'SL_25_50_42','Internal galleries',#1926,$,$); -#1934=IFCCLASSIFICATIONREFERENCE($,'SL_25_50_63','Planetariums',#1926,$,$); -#1935=IFCCLASSIFICATIONREFERENCE($,'SL_25_50_94','Viewing spaces',#1926,$,$); -#1936=IFCCLASSIFICATIONREFERENCE($,'SL_25_70','Information spaces',#1864,$,$); -#1937=IFCCLASSIFICATIONREFERENCE($,'SL_25_70_02','Archives',#1936,$,$); -#1938=IFCCLASSIFICATIONREFERENCE($,'SL_25_70_04','Audio-visual archives',#1936,$,$); -#1939=IFCCLASSIFICATIONREFERENCE($,'SL_25_70_05','Audio-visual study rooms',#1936,$,$); -#1940=IFCCLASSIFICATIONREFERENCE($,'SL_25_70_13','Conference rooms',#1936,$,$); -#1941=IFCCLASSIFICATIONREFERENCE($,'SL_25_70_47','Library rooms',#1936,$,$); -#1942=IFCCLASSIFICATIONREFERENCE($,'SL_25_70_72','Reading rooms',#1936,$,$); -#1943=IFCCLASSIFICATIONREFERENCE($,'SL_25_70_73','Records stores',#1936,$,$); -#1944=IFCCLASSIFICATIONREFERENCE($,'SL_25_90','Worship spaces',#1864,$,$); -#1945=IFCCLASSIFICATIONREFERENCE($,'SL_25_90_30','Faith spaces',#1944,$,$); -#1946=IFCCLASSIFICATIONREFERENCE($,'SL_25_90_65','Prayer rooms',#1944,$,$); -#1947=IFCCLASSIFICATIONREFERENCE($,'SL_25_90_78','Shrines',#1944,$,$); -#1948=IFCCLASSIFICATIONREFERENCE($,'SL_30','Industrial spaces',#1765,$,$); -#1949=IFCCLASSIFICATIONREFERENCE($,'SL_30_10','Mineral extraction spaces',#1948,$,$); -#1950=IFCCLASSIFICATIONREFERENCE($,'SL_30_10_57','Offshore oil and gas drilling spaces',#1949,$,$); -#1951=IFCCLASSIFICATIONREFERENCE($,'SL_30_10_59','Onshore oil and gas drilling spaces',#1949,$,$); -#1952=IFCCLASSIFICATIONREFERENCE($,'SL_30_10_69','Quarrying areas',#1949,$,$); -#1953=IFCCLASSIFICATIONREFERENCE($,'SL_30_10_85','Surface mine workings',#1949,$,$); -#1954=IFCCLASSIFICATIONREFERENCE($,'SL_30_10_91','Underground mine chambers',#1949,$,$); -#1955=IFCCLASSIFICATIONREFERENCE($,'SL_30_10_93','Underground mine shafts',#1949,$,$); -#1956=IFCCLASSIFICATIONREFERENCE($,'SL_30_10_94','Underground mine tunnels',#1949,$,$); -#1957=IFCCLASSIFICATIONREFERENCE($,'SL_30_20','Nuclear and chemical management spaces',#1948,$,$); -#1958=IFCCLASSIFICATIONREFERENCE($,'SL_30_20_70','Radioactive decontamination spaces',#1957,$,$); -#1959=IFCCLASSIFICATIONREFERENCE($,'SL_30_20_75','Radioactive waste package transfer spaces',#1957,$,$); -#1960=IFCCLASSIFICATIONREFERENCE($,'SL_30_30','Mineral processing spaces',#1948,$,$); -#1961=IFCCLASSIFICATIONREFERENCE($,'SL_30_30_33','Gas processing spaces',#1960,$,$); -#1962=IFCCLASSIFICATIONREFERENCE($,'SL_30_30_58','Oil processing spaces',#1960,$,$); -#1963=IFCCLASSIFICATIONREFERENCE($,'SL_30_30_59','Ore processing spaces',#1960,$,$); -#1964=IFCCLASSIFICATIONREFERENCE($,'SL_30_40','Animal and plant products processing spaces',#1948,$,$); -#1965=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_07','Bottling rooms',#1964,$,$); -#1966=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_10','Butter making rooms',#1964,$,$); -#1967=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_18','Cheese making rooms',#1964,$,$); -#1968=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_30','Fish processing rooms',#1964,$,$); -#1969=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_32','Fresh fruit and vegetable packing rooms',#1964,$,$); -#1970=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_44','Juicing rooms',#1964,$,$); -#1971=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_50','Meat processing rooms',#1964,$,$); -#1972=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_54','Milk processing rooms',#1964,$,$); -#1973=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_63','Plant fibre sorting rooms',#1964,$,$); -#1974=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_65','Poultry and game processing rooms',#1964,$,$); -#1975=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_75','Saw mills',#1964,$,$); -#1976=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_80','Silk production rooms',#1964,$,$); -#1977=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_82','Spinning rooms',#1964,$,$); -#1978=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_87','Tanneries',#1964,$,$); -#1979=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_88','Threshing rooms',#1964,$,$); -#1980=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_90','Tobacco drying rooms',#1964,$,$); -#1981=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_96','Weaving rooms',#1964,$,$); -#1982=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_98','Wool sorting rooms',#1964,$,$); -#1983=IFCCLASSIFICATIONREFERENCE($,'SL_30_50','Manufacturing spaces',#1948,$,$); -#1984=IFCCLASSIFICATIONREFERENCE($,'SL_30_50_27','Electronics clean rooms',#1983,$,$); -#1985=IFCCLASSIFICATIONREFERENCE($,'SL_30_50_30','Heavy industrial spaces',#1983,$,$); -#1986=IFCCLASSIFICATIONREFERENCE($,'SL_30_50_40','Kiln rooms',#1983,$,$); -#1987=IFCCLASSIFICATIONREFERENCE($,'SL_30_50_43','Light industrial spaces',#1983,$,$); -#1988=IFCCLASSIFICATIONREFERENCE($,'SL_30_50_50','Manufacturing workshops',#1983,$,$); -#1989=IFCCLASSIFICATIONREFERENCE($,'SL_30_50_60','Packaging lines',#1983,$,$); -#1990=IFCCLASSIFICATIONREFERENCE($,'SL_30_50_61','Paint spray booths',#1983,$,$); -#1991=IFCCLASSIFICATIONREFERENCE($,'SL_30_50_62','Pharmaceuticals clean rooms',#1983,$,$); -#1992=IFCCLASSIFICATIONREFERENCE($,'SL_30_50_64','Printing spaces',#1983,$,$); -#1993=IFCCLASSIFICATIONREFERENCE($,'SL_30_60','Cleaning and maintenance spaces',#1948,$,$); -#1994=IFCCLASSIFICATIONREFERENCE($,'SL_30_60_11','Caretaker rooms',#1993,$,$); -#1995=IFCCLASSIFICATIONREFERENCE($,'SL_30_60_13','Clothes drying and airing rooms',#1993,$,$); -#1996=IFCCLASSIFICATIONREFERENCE($,'SL_30_60_22','Decontamination spaces',#1993,$,$); -#1997=IFCCLASSIFICATIONREFERENCE($,'SL_30_60_24','Dry cleaning spaces',#1993,$,$); -#1998=IFCCLASSIFICATIONREFERENCE($,'SL_30_60_42','Ironing rooms',#1993,$,$); -#1999=IFCCLASSIFICATIONREFERENCE($,'SL_30_60_46','Laundrettes',#1993,$,$); -#2000=IFCCLASSIFICATIONREFERENCE($,'SL_30_60_47','Laundries',#1993,$,$); -#2001=IFCCLASSIFICATIONREFERENCE($,'SL_30_60_50','Maintenance workshops',#1993,$,$); -#2002=IFCCLASSIFICATIONREFERENCE($,'SL_30_60_75','Service laundries',#1993,$,$); -#2003=IFCCLASSIFICATIONREFERENCE($,'SL_30_60_94','Vehicle washes',#1993,$,$); -#2004=IFCCLASSIFICATIONREFERENCE($,'SL_30_60_96','Wash up spaces',#1993,$,$); -#2005=IFCCLASSIFICATIONREFERENCE($,'SL_30_80','Kinetic power generation spaces',#1948,$,$); -#2006=IFCCLASSIFICATIONREFERENCE($,'SL_30_80_96','Water mill houses',#2005,$,$); -#2007=IFCCLASSIFICATIONREFERENCE($,'SL_30_80_97','Wind mill houses',#2005,$,$); -#2008=IFCCLASSIFICATIONREFERENCE($,'SL_30_85','Marine and water maintenance spaces',#1948,$,$); -#2009=IFCCLASSIFICATIONREFERENCE($,'SL_30_85_08','Boat repair spaces',#2008,$,$); -#2010=IFCCLASSIFICATIONREFERENCE($,'SL_30_85_24','Dry dock chambers',#2008,$,$); -#2011=IFCCLASSIFICATIONREFERENCE($,'SL_30_85_30','Floating docks',#2008,$,$); -#2012=IFCCLASSIFICATIONREFERENCE($,'SL_30_85_97','Wet docks',#2008,$,$); -#2013=IFCCLASSIFICATIONREFERENCE($,'SL_30_90','Warehousing and distribution spaces',#1948,$,$); -#2014=IFCCLASSIFICATIONREFERENCE($,'SL_30_90_33','Goods delivery bays',#2013,$,$); -#2015=IFCCLASSIFICATIONREFERENCE($,'SL_30_90_48','Loading docks',#2013,$,$); -#2016=IFCCLASSIFICATIONREFERENCE($,'SL_30_90_80','Sorting and distribution spaces',#2013,$,$); -#2017=IFCCLASSIFICATIONREFERENCE($,'SL_30_90_84','Storage yards',#2013,$,$); -#2018=IFCCLASSIFICATIONREFERENCE($,'SL_30_90_96','Warehouse spaces',#2013,$,$); -#2019=IFCCLASSIFICATIONREFERENCE($,'SL_32','Water and land management spaces',#1765,$,$); -#2020=IFCCLASSIFICATIONREFERENCE($,'SL_32_10','Agricultural and horticultural spaces',#2019,$,$); -#2021=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_03','Arable fields',#2020,$,$); -#2022=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_26','Farm yards',#2020,$,$); -#2023=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_28','Fisheries',#2020,$,$); -#2024=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_30','Fish farm tanks',#2020,$,$); -#2025=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_34','Glasshouse spaces',#2020,$,$); -#2026=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_39','Hothouse spaces',#2020,$,$); -#2027=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_47','Livestock fields',#2020,$,$); -#2028=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_52','Milking parlours',#2020,$,$); -#2029=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_55','Mushroom cultivation spaces',#2020,$,$); -#2030=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_60','Paddocks',#2020,$,$); -#2031=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_65','Poly tunnel spaces',#2020,$,$); -#2032=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_66','Poultry batteries',#2020,$,$); -#2033=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_77','Shearing spaces',#2020,$,$); -#2034=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_78','Sheep dips',#2020,$,$); -#2035=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_94','Vineyard spaces',#2020,$,$); -#2036=IFCCLASSIFICATIONREFERENCE($,'SL_32_35','Ground spaces',#2019,$,$); -#2037=IFCCLASSIFICATIONREFERENCE($,'SL_32_35_22','Decking areas',#2036,$,$); -#2038=IFCCLASSIFICATIONREFERENCE($,'SL_32_35_24','Driveways',#2036,$,$); -#2039=IFCCLASSIFICATIONREFERENCE($,'SL_32_35_30','Flower beds',#2036,$,$); -#2040=IFCCLASSIFICATIONREFERENCE($,'SL_32_35_46','Lawns',#2036,$,$); -#2041=IFCCLASSIFICATIONREFERENCE($,'SL_32_35_60','Patios',#2036,$,$); -#2042=IFCCLASSIFICATIONREFERENCE($,'SL_32_35_94','Vegetable gardens',#2036,$,$); -#2043=IFCCLASSIFICATIONREFERENCE($,'SL_32_40','Land managed spaces',#2019,$,$); -#2044=IFCCLASSIFICATIONREFERENCE($,'SL_32_40_26','Easement access areas',#2043,$,$); -#2045=IFCCLASSIFICATIONREFERENCE($,'SL_32_40_90','Tree protection zones',#2043,$,$); -#2046=IFCCLASSIFICATIONREFERENCE($,'SL_32_50','Marine ways and waterway spaces',#2019,$,$); -#2047=IFCCLASSIFICATIONREFERENCE($,'SL_32_50_06','Beach ramps',#2046,$,$); -#2048=IFCCLASSIFICATIONREFERENCE($,'SL_32_50_18','Deep berths',#2046,$,$); -#2049=IFCCLASSIFICATIONREFERENCE($,'SL_32_50_47','Lifeboat vessel launch spaces',#2046,$,$); -#2050=IFCCLASSIFICATIONREFERENCE($,'SL_32_50_79','Slipways',#2046,$,$); -#2051=IFCCLASSIFICATIONREFERENCE($,'SL_32_60','Marine and waterside spaces',#2019,$,$); -#2052=IFCCLASSIFICATIONREFERENCE($,'SL_32_60_06','Beaches',#2051,$,$); -#2053=IFCCLASSIFICATIONREFERENCE($,'SL_32_60_55','Mudflats',#2051,$,$); -#2054=IFCCLASSIFICATIONREFERENCE($,'SL_32_60_65','Pontoons',#2051,$,$); -#2055=IFCCLASSIFICATIONREFERENCE($,'SL_32_60_76','Sand dunes',#2051,$,$); -#2056=IFCCLASSIFICATIONREFERENCE($,'SL_32_65','Natural spaces',#2019,$,$); -#2057=IFCCLASSIFICATIONREFERENCE($,'SL_32_65_37','Heathlands',#2056,$,$); -#2058=IFCCLASSIFICATIONREFERENCE($,'SL_32_65_50','Marshes and wet grasslands',#2056,$,$); -#2059=IFCCLASSIFICATIONREFERENCE($,'SL_32_65_51','Meadows',#2056,$,$); -#2060=IFCCLASSIFICATIONREFERENCE($,'SL_32_65_53','Moorlands',#2056,$,$); -#2061=IFCCLASSIFICATIONREFERENCE($,'SL_32_65_59','Open grasslands',#2056,$,$); -#2062=IFCCLASSIFICATIONREFERENCE($,'SL_32_65_71','River beds',#2056,$,$); -#2063=IFCCLASSIFICATIONREFERENCE($,'SL_32_65_72','River reaches',#2056,$,$); -#2064=IFCCLASSIFICATIONREFERENCE($,'SL_32_65_73','Rocks and screes',#2056,$,$); -#2065=IFCCLASSIFICATIONREFERENCE($,'SL_32_65_76','Scrub',#2056,$,$); -#2066=IFCCLASSIFICATIONREFERENCE($,'SL_32_65_82','Species rich grassland',#2056,$,$); -#2067=IFCCLASSIFICATIONREFERENCE($,'SL_32_65_95','Washland',#2056,$,$); -#2068=IFCCLASSIFICATIONREFERENCE($,'SL_32_80','Semi-natural spaces',#2019,$,$); -#2069=IFCCLASSIFICATIONREFERENCE($,'SL_32_80_03','Amenity grass areas',#2068,$,$); -#2070=IFCCLASSIFICATIONREFERENCE($,'SL_32_80_08','Brownfield sites',#2068,$,$); -#2071=IFCCLASSIFICATIONREFERENCE($,'SL_32_80_23','Disused mineral extraction sites',#2068,$,$); -#2072=IFCCLASSIFICATIONREFERENCE($,'SL_32_80_50','Mowing strips',#2068,$,$); -#2073=IFCCLASSIFICATIONREFERENCE($,'SL_32_80_89','Transport corridor verges',#2068,$,$); -#2074=IFCCLASSIFICATIONREFERENCE($,'SL_35','Medical, health, welfare and sanitary spaces',#1765,$,$); -#2075=IFCCLASSIFICATIONREFERENCE($,'SL_35_10','Medical spaces',#2074,$,$); -#2076=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_08','Birthing rooms',#2075,$,$); -#2077=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_10','Burns units',#2075,$,$); -#2078=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_15','Consulting rooms',#2075,$,$); -#2079=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_30','First aid posts',#2075,$,$); -#2080=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_31','First aid rooms',#2075,$,$); -#2081=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_36','Hearing test rooms',#2075,$,$); -#2082=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_39','Hydrotherapy pools',#2075,$,$); -#2083=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_42','Intensive care units',#2075,$,$); -#2084=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_43','Isolation units',#2075,$,$); -#2085=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_51','Medical scanning and x-ray rooms',#2075,$,$); -#2086=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_53','Medical treatment spaces',#2075,$,$); -#2087=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_58','Occupational therapy rooms',#2075,$,$); -#2088=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_59','Operating theatres',#2075,$,$); -#2089=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_64','Pharmaceutical dispensaries',#2075,$,$); -#2090=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_65','Phototherapy spaces',#2075,$,$); -#2091=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_66','Physiotherapy rooms',#2075,$,$); -#2092=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_70','Radiography rooms',#2075,$,$); -#2093=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_71','Radiotherapy rooms',#2075,$,$); -#2094=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_73','Recovery rooms',#2075,$,$); -#2095=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_74','Rehabilitation rooms',#2075,$,$); -#2096=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_96','Wards',#2075,$,$); -#2097=IFCCLASSIFICATIONREFERENCE($,'SL_35_50','Welfare spaces',#2074,$,$); -#2098=IFCCLASSIFICATIONREFERENCE($,'SL_35_50_17','Cr\X2\00E8\X0\ches and nurseries',#2097,$,$); -#2099=IFCCLASSIFICATIONREFERENCE($,'SL_35_50_21','Day care spaces',#2097,$,$); -#2100=IFCCLASSIFICATIONREFERENCE($,'SL_35_50_60','Parent and baby rooms',#2097,$,$); -#2101=IFCCLASSIFICATIONREFERENCE($,'SL_35_50_75','Sauna rooms',#2097,$,$); -#2102=IFCCLASSIFICATIONREFERENCE($,'SL_35_50_90','Treatment rooms',#2097,$,$); -#2103=IFCCLASSIFICATIONREFERENCE($,'SL_35_60','Food management spaces',#2074,$,$); -#2104=IFCCLASSIFICATIONREFERENCE($,'SL_35_60_14','Commercial kitchens',#2103,$,$); -#2105=IFCCLASSIFICATIONREFERENCE($,'SL_35_60_16','Cooking spaces',#2103,$,$); -#2106=IFCCLASSIFICATIONREFERENCE($,'SL_35_60_30','Food preparation areas',#2103,$,$); -#2107=IFCCLASSIFICATIONREFERENCE($,'SL_35_60_56','Non-domestic kitchens',#2103,$,$); -#2108=IFCCLASSIFICATIONREFERENCE($,'SL_35_70','Funerary spaces',#2074,$,$); -#2109=IFCCLASSIFICATIONREFERENCE($,'SL_35_70_12','Cemetery plots',#2108,$,$); -#2110=IFCCLASSIFICATIONREFERENCE($,'SL_35_70_15','Columbariums',#2108,$,$); -#2111=IFCCLASSIFICATIONREFERENCE($,'SL_35_70_18','Crematorium oven rooms',#2108,$,$); -#2112=IFCCLASSIFICATIONREFERENCE($,'SL_35_70_32','Funeral vaults',#2108,$,$); -#2113=IFCCLASSIFICATIONREFERENCE($,'SL_35_70_50','Mausoleums',#2108,$,$); -#2114=IFCCLASSIFICATIONREFERENCE($,'SL_35_70_90','Tombs',#2108,$,$); -#2115=IFCCLASSIFICATIONREFERENCE($,'SL_35_80','Sanitary spaces',#2074,$,$); -#2116=IFCCLASSIFICATIONREFERENCE($,'SL_35_80_06','Baby changing rooms',#2115,$,$); -#2117=IFCCLASSIFICATIONREFERENCE($,'SL_35_80_08','Bathrooms',#2115,$,$); -#2118=IFCCLASSIFICATIONREFERENCE($,'SL_35_80_59','Open shower areas',#2115,$,$); -#2119=IFCCLASSIFICATIONREFERENCE($,'SL_35_80_68','Public toilets',#2115,$,$); -#2120=IFCCLASSIFICATIONREFERENCE($,'SL_35_80_80','Showers',#2115,$,$); -#2121=IFCCLASSIFICATIONREFERENCE($,'SL_35_80_89','Toilets',#2115,$,$); -#2122=IFCCLASSIFICATIONREFERENCE($,'SL_35_85','Animal spaces',#2074,$,$); -#2123=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_00','Animal arks',#2122,$,$); -#2124=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_01','Animal cages',#2122,$,$); -#2125=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_03','Animal enclosures',#2122,$,$); -#2126=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_04','Animal exercise arenas',#2122,$,$); -#2127=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_05','Aviaries',#2122,$,$); -#2128=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_12','Cattle byres',#2122,$,$); -#2129=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_39','Fish tanks',#2122,$,$); -#2130=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_45','Kennels',#2122,$,$); -#2131=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_47','Loose boxes',#2122,$,$); -#2132=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_62','Pens',#2122,$,$); -#2133=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_83','Stables',#2122,$,$); -#2134=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_84','Stable yards',#2122,$,$); -#2135=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_85','Stalls',#2122,$,$); -#2136=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_86','Sties',#2122,$,$); -#2137=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_88','Tack rooms',#2122,$,$); -#2138=IFCCLASSIFICATIONREFERENCE($,'SL_35_90','Animal medical, health, welfare and funerary spaces',#2074,$,$); -#2139=IFCCLASSIFICATIONREFERENCE($,'SL_35_90_10','Animal burial plots',#2138,$,$); -#2140=IFCCLASSIFICATIONREFERENCE($,'SL_35_90_15','Animal clinics',#2138,$,$); -#2141=IFCCLASSIFICATIONREFERENCE($,'SL_35_90_22','Animal dispensaries',#2138,$,$); -#2142=IFCCLASSIFICATIONREFERENCE($,'SL_35_90_32','Animal funerary spaces',#2138,$,$); -#2143=IFCCLASSIFICATIONREFERENCE($,'SL_35_90_34','Animal grooming facilities',#2138,$,$); -#2144=IFCCLASSIFICATIONREFERENCE($,'SL_35_90_37','Animal hydrotherapy pools',#2138,$,$); -#2145=IFCCLASSIFICATIONREFERENCE($,'SL_35_90_59','Animal operating theatres',#2138,$,$); -#2146=IFCCLASSIFICATIONREFERENCE($,'SL_35_90_72','Animal wards',#2138,$,$); -#2147=IFCCLASSIFICATIONREFERENCE($,'SL_40','Recreational spaces',#1765,$,$); -#2148=IFCCLASSIFICATIONREFERENCE($,'SL_40_05','Amusement spaces',#2147,$,$); -#2149=IFCCLASSIFICATIONREFERENCE($,'SL_40_05_03','Amusement arcades',#2148,$,$); -#2150=IFCCLASSIFICATIONREFERENCE($,'SL_40_05_13','Casino floors',#2148,$,$); -#2151=IFCCLASSIFICATIONREFERENCE($,'SL_40_05_42','Indoor fairground spaces',#2148,$,$); -#2152=IFCCLASSIFICATIONREFERENCE($,'SL_40_05_43','Indoor play spaces',#2148,$,$); -#2153=IFCCLASSIFICATIONREFERENCE($,'SL_40_05_58','Observation decks',#2148,$,$); -#2154=IFCCLASSIFICATIONREFERENCE($,'SL_40_05_59','Outdoor activity areas',#2148,$,$); -#2155=IFCCLASSIFICATIONREFERENCE($,'SL_40_05_60','Outdoor fairground spaces',#2148,$,$); -#2156=IFCCLASSIFICATIONREFERENCE($,'SL_40_05_61','Outdoor playgrounds',#2148,$,$); -#2157=IFCCLASSIFICATIONREFERENCE($,'SL_40_05_68','Public parks and gardens',#2148,$,$); -#2158=IFCCLASSIFICATIONREFERENCE($,'SL_40_20','Dining spaces',#2147,$,$); -#2159=IFCCLASSIFICATIONREFERENCE($,'SL_40_20_06','Bars',#2158,$,$); -#2160=IFCCLASSIFICATIONREFERENCE($,'SL_40_20_09','Beverage stations',#2158,$,$); -#2161=IFCCLASSIFICATIONREFERENCE($,'SL_40_20_27','Enclosed dining areas',#2158,$,$); -#2162=IFCCLASSIFICATIONREFERENCE($,'SL_40_20_28','Food courts',#2158,$,$); -#2163=IFCCLASSIFICATIONREFERENCE($,'SL_40_20_59','Outdoor dining areas',#2158,$,$); -#2164=IFCCLASSIFICATIONREFERENCE($,'SL_40_60','Performing arts spaces',#2147,$,$); -#2165=IFCCLASSIFICATIONREFERENCE($,'SL_40_60_05','Auditoriums',#2164,$,$); -#2166=IFCCLASSIFICATIONREFERENCE($,'SL_40_60_06','Bandstands',#2164,$,$); -#2167=IFCCLASSIFICATIONREFERENCE($,'SL_40_60_11','Cat walks',#2164,$,$); -#2168=IFCCLASSIFICATIONREFERENCE($,'SL_40_60_13','Circus rings',#2164,$,$); -#2169=IFCCLASSIFICATIONREFERENCE($,'SL_40_60_21','Dance floors',#2164,$,$); -#2170=IFCCLASSIFICATIONREFERENCE($,'SL_40_60_31','Fixed stages',#2164,$,$); -#2171=IFCCLASSIFICATIONREFERENCE($,'SL_40_60_40','Indoor theatre spaces',#2164,$,$); -#2172=IFCCLASSIFICATIONREFERENCE($,'SL_40_60_52','Mobile stages',#2164,$,$); -#2173=IFCCLASSIFICATIONREFERENCE($,'SL_40_60_58','Orchestra pits',#2164,$,$); -#2174=IFCCLASSIFICATIONREFERENCE($,'SL_40_60_59','Outdoor theatre spaces',#2164,$,$); -#2175=IFCCLASSIFICATIONREFERENCE($,'SL_40_60_78','Sound recording studios',#2164,$,$); -#2176=IFCCLASSIFICATIONREFERENCE($,'SL_40_60_80','Sound shells',#2164,$,$); -#2177=IFCCLASSIFICATIONREFERENCE($,'SL_40_60_81','Sound stages',#2164,$,$); -#2178=IFCCLASSIFICATIONREFERENCE($,'SL_40_65','Performing arts ancillary spaces',#2147,$,$); -#2179=IFCCLASSIFICATIONREFERENCE($,'SL_40_65_04','Audience lobbies',#2178,$,$); -#2180=IFCCLASSIFICATIONREFERENCE($,'SL_40_65_24','Dressing rooms',#2178,$,$); -#2181=IFCCLASSIFICATIONREFERENCE($,'SL_40_65_35','Green rooms',#2178,$,$); -#2182=IFCCLASSIFICATIONREFERENCE($,'SL_40_65_47','Lighting control booths',#2178,$,$); -#2183=IFCCLASSIFICATIONREFERENCE($,'SL_40_65_66','Projection booths',#2178,$,$); -#2184=IFCCLASSIFICATIONREFERENCE($,'SL_40_65_70','Recording control booths',#2178,$,$); -#2185=IFCCLASSIFICATIONREFERENCE($,'SL_40_65_72','Rehearsal rooms',#2178,$,$); -#2186=IFCCLASSIFICATIONREFERENCE($,'SL_40_65_76','Scenery control booths',#2178,$,$); -#2187=IFCCLASSIFICATIONREFERENCE($,'SL_40_65_79','Sound control booths',#2178,$,$); -#2188=IFCCLASSIFICATIONREFERENCE($,'SL_40_65_80','Sound locks',#2178,$,$); -#2189=IFCCLASSIFICATIONREFERENCE($,'SL_40_65_85','Stage wings',#2178,$,$); -#2190=IFCCLASSIFICATIONREFERENCE($,'SL_42','Sport and activity spaces',#1765,$,$); -#2191=IFCCLASSIFICATIONREFERENCE($,'SL_42_15','Courts, pitches and field sports spaces',#2190,$,$); -#2192=IFCCLASSIFICATIONREFERENCE($,'SL_42_15_37','High jump areas',#2191,$,$); -#2193=IFCCLASSIFICATIONREFERENCE($,'SL_42_15_42','Indoor sports courts and pitches',#2191,$,$); -#2194=IFCCLASSIFICATIONREFERENCE($,'SL_42_15_44','Javelin throwing areas',#2191,$,$); -#2195=IFCCLASSIFICATIONREFERENCE($,'SL_42_15_47','Long jump tracks and pits',#2191,$,$); -#2196=IFCCLASSIFICATIONREFERENCE($,'SL_42_15_59','Outdoor sports courts',#2191,$,$); -#2197=IFCCLASSIFICATIONREFERENCE($,'SL_42_15_60','Outdoor sports pitches and fields',#2191,$,$); -#2198=IFCCLASSIFICATIONREFERENCE($,'SL_42_15_65','Pole vaulting areas',#2191,$,$); -#2199=IFCCLASSIFICATIONREFERENCE($,'SL_42_15_74','Running tracks',#2191,$,$); -#2200=IFCCLASSIFICATIONREFERENCE($,'SL_42_15_78','Shot put and hammer throwing areas',#2191,$,$); -#2201=IFCCLASSIFICATIONREFERENCE($,'SL_42_40','Indoor activity spaces',#2190,$,$); -#2202=IFCCLASSIFICATIONREFERENCE($,'SL_42_40_09','Bouldering spaces',#2201,$,$); -#2203=IFCCLASSIFICATIONREFERENCE($,'SL_42_40_14','Climbing wall areas',#2201,$,$); -#2204=IFCCLASSIFICATIONREFERENCE($,'SL_42_40_20','Cycle tracks',#2201,$,$); -#2205=IFCCLASSIFICATIONREFERENCE($,'SL_42_40_23','Dojo',#2201,$,$); -#2206=IFCCLASSIFICATIONREFERENCE($,'SL_42_40_30','Fitness rooms',#2201,$,$); -#2207=IFCCLASSIFICATIONREFERENCE($,'SL_42_40_35','Gymnasiums',#2201,$,$); -#2208=IFCCLASSIFICATIONREFERENCE($,'SL_42_40_37','Gymnastics areas',#2201,$,$); -#2209=IFCCLASSIFICATIONREFERENCE($,'SL_42_40_79','Snooker, billiards and pool halls',#2201,$,$); -#2210=IFCCLASSIFICATIONREFERENCE($,'SL_42_40_90','Ten pin bowling alleys',#2201,$,$); -#2211=IFCCLASSIFICATIONREFERENCE($,'SL_42_55','Outdoor activity spaces',#2190,$,$); -#2212=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_01','Archery ranges',#2211,$,$); -#2213=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_07','BMX cycling tracks',#2211,$,$); -#2214=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_08','Bowling greens',#2211,$,$); -#2215=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_17','Cross-country cycling courses',#2211,$,$); -#2216=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_18','Cross country equestrian courses',#2211,$,$); -#2217=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_19','Cross-country rallying courses',#2211,$,$); -#2218=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_20','Cross-country running courses',#2211,$,$); -#2219=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_23','Dog racing tracks',#2211,$,$); -#2220=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_26','Equestrian arenas',#2211,$,$); -#2221=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_35','Golf fairways',#2211,$,$); -#2222=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_39','Horse racing courses',#2211,$,$); -#2223=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_53','Motor racing tracks',#2211,$,$); -#2224=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_60','Parkour courses',#2211,$,$); -#2225=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_65','Putting greens',#2211,$,$); -#2226=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_72','Road running courses',#2211,$,$); -#2227=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_76','Skateboarding parks',#2211,$,$); -#2228=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_82','Speedway tracks',#2211,$,$); -#2229=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_96','Walking trails',#2211,$,$); -#2230=IFCCLASSIFICATIONREFERENCE($,'SL_42_80','Sports and activity ancillary spaces',#2190,$,$); -#2231=IFCCLASSIFICATIONREFERENCE($,'SL_42_80_65','Press boxes',#2230,$,$); -#2232=IFCCLASSIFICATIONREFERENCE($,'SL_42_80_88','Technical areas and dugouts',#2230,$,$); -#2233=IFCCLASSIFICATIONREFERENCE($,'SL_42_85','Swimming spaces',#2190,$,$); -#2234=IFCCLASSIFICATIONREFERENCE($,'SL_42_85_23','Diving pools',#2233,$,$); -#2235=IFCCLASSIFICATIONREFERENCE($,'SL_42_85_64','Plunge pools',#2233,$,$); -#2236=IFCCLASSIFICATIONREFERENCE($,'SL_42_85_80','Spa pools',#2233,$,$); -#2237=IFCCLASSIFICATIONREFERENCE($,'SL_42_85_82','Splash pools',#2233,$,$); -#2238=IFCCLASSIFICATIONREFERENCE($,'SL_42_85_83','Swimming pools',#2233,$,$); -#2239=IFCCLASSIFICATIONREFERENCE($,'SL_42_85_94','Water flumes, slides and tubes',#2233,$,$); -#2240=IFCCLASSIFICATIONREFERENCE($,'SL_42_85_97','Wave pools',#2233,$,$); -#2241=IFCCLASSIFICATIONREFERENCE($,'SL_42_85_98','Whirlpools',#2233,$,$); -#2242=IFCCLASSIFICATIONREFERENCE($,'SL_42_90','Water activity spaces',#2190,$,$); -#2243=IFCCLASSIFICATIONREFERENCE($,'SL_42_90_11','Canoe slalom courses',#2242,$,$); -#2244=IFCCLASSIFICATIONREFERENCE($,'SL_42_90_12','Canoe sprint courses',#2242,$,$); -#2245=IFCCLASSIFICATIONREFERENCE($,'SL_42_90_50','Motor boat courses',#2242,$,$); -#2246=IFCCLASSIFICATIONREFERENCE($,'SL_42_90_73','Rowing courses',#2242,$,$); -#2247=IFCCLASSIFICATIONREFERENCE($,'SL_42_90_75','Sailing courses',#2242,$,$); -#2248=IFCCLASSIFICATIONREFERENCE($,'SL_42_90_97','Water skiing courses',#2242,$,$); -#2249=IFCCLASSIFICATIONREFERENCE($,'SL_42_90_98','White water canoe courses',#2242,$,$); -#2250=IFCCLASSIFICATIONREFERENCE($,'SL_42_95','Winter sports spaces',#2190,$,$); -#2251=IFCCLASSIFICATIONREFERENCE($,'SL_42_95_02','Alpine skiing courses',#2250,$,$); -#2252=IFCCLASSIFICATIONREFERENCE($,'SL_42_95_04','Artificial ski slopes',#2250,$,$); -#2253=IFCCLASSIFICATIONREFERENCE($,'SL_42_95_08','Bobsleigh courses',#2250,$,$); -#2254=IFCCLASSIFICATIONREFERENCE($,'SL_42_95_19','Cross-country skiing courses',#2250,$,$); -#2255=IFCCLASSIFICATIONREFERENCE($,'SL_42_95_20','Curling rinks',#2250,$,$); -#2256=IFCCLASSIFICATIONREFERENCE($,'SL_42_95_32','Freestyle skiing courses',#2250,$,$); -#2257=IFCCLASSIFICATIONREFERENCE($,'SL_42_95_40','Ice skating rinks',#2250,$,$); -#2258=IFCCLASSIFICATIONREFERENCE($,'SL_42_95_76','Short track speed skating tracks',#2250,$,$); -#2259=IFCCLASSIFICATIONREFERENCE($,'SL_42_95_79','Ski jumps',#2250,$,$); -#2260=IFCCLASSIFICATIONREFERENCE($,'SL_42_95_80','Snowboarding courses',#2250,$,$); -#2261=IFCCLASSIFICATIONREFERENCE($,'SL_42_95_83','Speed skating courses',#2250,$,$); -#2262=IFCCLASSIFICATIONREFERENCE($,'SL_45','Residential spaces',#1765,$,$); -#2263=IFCCLASSIFICATIONREFERENCE($,'SL_45_10','Living spaces',#2262,$,$); -#2264=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_06','Balconies',#2263,$,$); -#2265=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_08','Bedroom-studies',#2263,$,$); -#2266=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_09','Bedrooms',#2263,$,$); -#2267=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_12','Caravan pitches',#2263,$,$); -#2268=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_14','Communal living rooms',#2263,$,$); -#2269=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_16','Concierge offices',#2263,$,$); -#2270=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_18','Conservatories',#2263,$,$); -#2271=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_22','Domestic dining rooms',#2263,$,$); -#2272=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_23','Domestic kitchens',#2263,$,$); -#2273=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_24','Dormitories',#2263,$,$); -#2274=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_37','Hotel rooms',#2263,$,$); -#2275=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_44','Kitchen-dining rooms',#2263,$,$); -#2276=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_49','Living rooms',#2263,$,$); -#2277=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_57','Nursing home bedrooms',#2263,$,$); -#2278=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_60','Panic rooms',#2263,$,$); -#2279=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_85','Studies',#2263,$,$); -#2280=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_88','Tent pitches',#2263,$,$); -#2281=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_93','Utility rooms',#2263,$,$); -#2282=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_94','Verandas',#2263,$,$); -#2283=IFCCLASSIFICATIONREFERENCE($,'SL_50','Waste disposal spaces and locations',#1765,$,$); -#2284=IFCCLASSIFICATIONREFERENCE($,'SL_50_10','Gas waste collection spaces',#2283,$,$); -#2285=IFCCLASSIFICATIONREFERENCE($,'SL_50_20','Wet waste collection spaces',#2283,$,$); -#2286=IFCCLASSIFICATIONREFERENCE($,'SL_50_30','Drainage collection spaces',#2283,$,$); -#2287=IFCCLASSIFICATIONREFERENCE($,'SL_50_35','Drainage collection locations',#2283,$,$); -#2288=IFCCLASSIFICATIONREFERENCE($,'SL_50_35_36','Grip inlets',#2287,$,$); -#2289=IFCCLASSIFICATIONREFERENCE($,'SL_50_35_41','Inlet discharge',#2287,$,$); -#2290=IFCCLASSIFICATIONREFERENCE($,'SL_50_35_59','Outlet discharge',#2287,$,$); -#2291=IFCCLASSIFICATIONREFERENCE($,'SL_50_40','Dry waste collection spaces',#2283,$,$); -#2292=IFCCLASSIFICATIONREFERENCE($,'SL_50_40_72','Refuse storage space',#2291,$,$); -#2293=IFCCLASSIFICATIONREFERENCE($,'SL_50_50','Gas waste treatment and disposal spaces',#2283,$,$); -#2294=IFCCLASSIFICATIONREFERENCE($,'SL_50_50_92','Waste gas treatment spaces',#2293,$,$); -#2295=IFCCLASSIFICATIONREFERENCE($,'SL_50_60','Wet waste treatment and disposal spaces',#2283,$,$); -#2296=IFCCLASSIFICATIONREFERENCE($,'SL_50_60_28','Evaporation ponds',#2295,$,$); -#2297=IFCCLASSIFICATIONREFERENCE($,'SL_50_60_94','Waste liquids treatment spaces',#2295,$,$); -#2298=IFCCLASSIFICATIONREFERENCE($,'SL_50_70','Drainage treatment and disposal spaces',#2283,$,$); -#2299=IFCCLASSIFICATIONREFERENCE($,'SL_50_75','Wastewater treatment and disposal spaces',#2283,$,$); -#2300=IFCCLASSIFICATIONREFERENCE($,'SL_50_75_40','Wastewater treatment spaces',#2299,$,$); -#2301=IFCCLASSIFICATIONREFERENCE($,'SL_50_75_70','Wastewater disposal spaces',#2299,$,$); -#2302=IFCCLASSIFICATIONREFERENCE($,'SL_50_80','Dry waste treatment and disposal spaces',#2283,$,$); -#2303=IFCCLASSIFICATIONREFERENCE($,'SL_50_80_40','Dry waste treatment spaces',#2302,$,$); -#2304=IFCCLASSIFICATIONREFERENCE($,'SL_50_80_70','Dry waste disposal spaces',#2302,$,$); -#2305=IFCCLASSIFICATIONREFERENCE($,'SL_55','Piped supply spaces',#1765,$,$); -#2306=IFCCLASSIFICATIONREFERENCE($,'SL_55_05','Gas extraction and treatment spaces',#2305,$,$); -#2307=IFCCLASSIFICATIONREFERENCE($,'SL_55_05_30','Gas extraction spaces',#2306,$,$); -#2308=IFCCLASSIFICATIONREFERENCE($,'SL_55_05_70','Gas treatment spaces',#2306,$,$); -#2309=IFCCLASSIFICATIONREFERENCE($,'SL_55_10','Liquid fuel extraction and treatment spaces',#2305,$,$); -#2310=IFCCLASSIFICATIONREFERENCE($,'SL_55_10_10','Oil extraction spaces',#2309,$,$); -#2311=IFCCLASSIFICATIONREFERENCE($,'SL_55_10_50','Oil treatment spaces',#2309,$,$); -#2312=IFCCLASSIFICATIONREFERENCE($,'SL_55_15','Water extraction and treatment spaces',#2305,$,$); -#2313=IFCCLASSIFICATIONREFERENCE($,'SL_55_15_10','Water extraction spaces',#2312,$,$); -#2314=IFCCLASSIFICATIONREFERENCE($,'SL_55_15_50','Water treatment spaces',#2312,$,$); -#2315=IFCCLASSIFICATIONREFERENCE($,'SL_55_20','Gas supply spaces',#2305,$,$); -#2316=IFCCLASSIFICATIONREFERENCE($,'SL_55_30','Fire extinguishing supply spaces',#2305,$,$); -#2317=IFCCLASSIFICATIONREFERENCE($,'SL_55_40','Steam supply spaces',#2305,$,$); -#2318=IFCCLASSIFICATIONREFERENCE($,'SL_55_50','Liquid fuel supply spaces',#2305,$,$); -#2319=IFCCLASSIFICATIONREFERENCE($,'SL_55_60','Process liquid supply spaces',#2305,$,$); -#2320=IFCCLASSIFICATIONREFERENCE($,'SL_55_65','Ventilation and air conditioning spaces',#2305,$,$); -#2321=IFCCLASSIFICATIONREFERENCE($,'SL_55_70','Water supply spaces',#2305,$,$); -#2322=IFCCLASSIFICATIONREFERENCE($,'SL_55_70_65','Private supply pipes',#2321,$,$); -#2323=IFCCLASSIFICATIONREFERENCE($,'SL_55_90','Piped solids supply spaces',#2305,$,$); -#2324=IFCCLASSIFICATIONREFERENCE($,'SL_60','Heating, cooling and refrigeration spaces',#1765,$,$); -#2325=IFCCLASSIFICATIONREFERENCE($,'SL_60_30','Rail and paving heating spaces',#2324,$,$); -#2326=IFCCLASSIFICATIONREFERENCE($,'SL_60_40','Space heating and cooling spaces',#2324,$,$); -#2327=IFCCLASSIFICATIONREFERENCE($,'SL_60_60','Refrigeration spaces',#2324,$,$); -#2328=IFCCLASSIFICATIONREFERENCE($,'SL_60_80','Drying spaces',#2324,$,$); -#2329=IFCCLASSIFICATIONREFERENCE($,'SL_60_80_25','Drying rooms',#2328,$,$); -#2330=IFCCLASSIFICATIONREFERENCE($,'SL_70','Electrical power generation and lighting spaces',#1765,$,$); -#2331=IFCCLASSIFICATIONREFERENCE($,'SL_70_10','Electrical power generation spaces',#2330,$,$); -#2332=IFCCLASSIFICATIONREFERENCE($,'SL_70_10_91','Turbine rooms',#2331,$,$); -#2333=IFCCLASSIFICATIONREFERENCE($,'SL_70_30','Electricity distribution and transmission spaces',#2330,$,$); -#2334=IFCCLASSIFICATIONREFERENCE($,'SL_70_30_35','High-voltage electricity substation chambers',#2333,$,$); -#2335=IFCCLASSIFICATIONREFERENCE($,'SL_70_30_45','Low-voltage electricity substation chambers',#2333,$,$); -#2336=IFCCLASSIFICATIONREFERENCE($,'SL_75','Communications, security, safety and protection spaces',#1765,$,$); -#2337=IFCCLASSIFICATIONREFERENCE($,'SL_75_10','Communications spaces',#2336,$,$); -#2338=IFCCLASSIFICATIONREFERENCE($,'SL_75_10_21','Communications equipment rooms',#2337,$,$); -#2339=IFCCLASSIFICATIONREFERENCE($,'SL_75_10_23','Digital data transmission networks',#2337,$,$); -#2340=IFCCLASSIFICATIONREFERENCE($,'SL_75_10_70','Radio broadcast control booths',#2337,$,$); -#2341=IFCCLASSIFICATIONREFERENCE($,'SL_75_10_73','Radio studios',#2337,$,$); -#2342=IFCCLASSIFICATIONREFERENCE($,'SL_75_10_88','Telecommunications control spaces',#2337,$,$); -#2343=IFCCLASSIFICATIONREFERENCE($,'SL_75_10_89','Telephone boxes and booths',#2337,$,$); -#2344=IFCCLASSIFICATIONREFERENCE($,'SL_75_10_90','Telephone exchange spaces',#2337,$,$); -#2345=IFCCLASSIFICATIONREFERENCE($,'SL_75_10_91','Television broadcast control booths',#2337,$,$); -#2346=IFCCLASSIFICATIONREFERENCE($,'SL_75_10_93','Television studios',#2337,$,$); -#2347=IFCCLASSIFICATIONREFERENCE($,'SL_75_30','Signalling spaces',#2336,$,$); -#2348=IFCCLASSIFICATIONREFERENCE($,'SL_75_30_80','Signal boxes',#2347,$,$); -#2349=IFCCLASSIFICATIONREFERENCE($,'SL_75_40','Electronic security spaces',#2336,$,$); -#2350=IFCCLASSIFICATIONREFERENCE($,'SL_75_40_28','Electronic security control rooms',#2349,$,$); -#2351=IFCCLASSIFICATIONREFERENCE($,'SL_75_50','Safety and protection spaces',#2336,$,$); -#2352=IFCCLASSIFICATIONREFERENCE($,'SL_75_60','Environmental safety',#2336,$,$); -#2353=IFCCLASSIFICATIONREFERENCE($,'SL_75_70','Control and management spaces',#2336,$,$); -#2354=IFCCLASSIFICATIONREFERENCE($,'SL_75_80','Protection spaces',#2336,$,$); -#2355=IFCCLASSIFICATIONREFERENCE($,'SL_80','Transport spaces',#1765,$,$); -#2356=IFCCLASSIFICATIONREFERENCE($,'SL_80_05','Aerospace ground spaces',#2355,$,$); -#2357=IFCCLASSIFICATIONREFERENCE($,'SL_80_05_02','Aeroplane landing strips',#2356,$,$); -#2358=IFCCLASSIFICATIONREFERENCE($,'SL_80_05_03','Aeroplane runways',#2356,$,$); -#2359=IFCCLASSIFICATIONREFERENCE($,'SL_80_05_04','Aircraft fuelling spaces',#2356,$,$); -#2360=IFCCLASSIFICATIONREFERENCE($,'SL_80_05_05','Aircraft manoeuvring areas',#2356,$,$); -#2361=IFCCLASSIFICATIONREFERENCE($,'SL_80_05_06','Aircraft standing areas',#2356,$,$); -#2362=IFCCLASSIFICATIONREFERENCE($,'SL_80_05_07','Aircraft storage spaces',#2356,$,$); -#2363=IFCCLASSIFICATIONREFERENCE($,'SL_80_05_33','Gliding runways',#2356,$,$); -#2364=IFCCLASSIFICATIONREFERENCE($,'SL_80_05_37','Hang gliding launch spaces',#2356,$,$); -#2365=IFCCLASSIFICATIONREFERENCE($,'SL_80_05_38','Helipads',#2356,$,$); -#2366=IFCCLASSIFICATIONREFERENCE($,'SL_80_05_82','Spacecraft landing strips',#2356,$,$); -#2367=IFCCLASSIFICATIONREFERENCE($,'SL_80_05_84','Spacecraft launch pads',#2356,$,$); -#2368=IFCCLASSIFICATIONREFERENCE($,'SL_80_10','Loading and embarkation spaces',#2355,$,$); -#2369=IFCCLASSIFICATIONREFERENCE($,'SL_80_10_06','Baggage claim areas',#2368,$,$); -#2370=IFCCLASSIFICATIONREFERENCE($,'SL_80_10_07','Baggage handling areas',#2368,$,$); -#2371=IFCCLASSIFICATIONREFERENCE($,'SL_80_10_09','Boarding areas',#2368,$,$); -#2372=IFCCLASSIFICATIONREFERENCE($,'SL_80_10_10','Bus stops',#2368,$,$); -#2373=IFCCLASSIFICATIONREFERENCE($,'SL_80_10_12','Cargo handling areas',#2368,$,$); -#2374=IFCCLASSIFICATIONREFERENCE($,'SL_80_10_13','Cargo loading areas',#2368,$,$); -#2375=IFCCLASSIFICATIONREFERENCE($,'SL_80_10_16','Concourses',#2368,$,$); -#2376=IFCCLASSIFICATIONREFERENCE($,'SL_80_10_20','Customs control areas',#2368,$,$); -#2377=IFCCLASSIFICATIONREFERENCE($,'SL_80_10_22','Departure lounges',#2368,$,$); -#2378=IFCCLASSIFICATIONREFERENCE($,'SL_80_10_55','Passenger gates',#2368,$,$); -#2379=IFCCLASSIFICATIONREFERENCE($,'SL_80_10_60','Passport control offices',#2368,$,$); -#2380=IFCCLASSIFICATIONREFERENCE($,'SL_80_10_77','Security screening areas',#2368,$,$); -#2381=IFCCLASSIFICATIONREFERENCE($,'SL_80_10_80','Ship gangways',#2368,$,$); -#2382=IFCCLASSIFICATIONREFERENCE($,'SL_80_15','Aerospace maintenance spaces',#2355,$,$); -#2383=IFCCLASSIFICATIONREFERENCE($,'SL_80_15_01','Aircraft cleaning spaces',#2382,$,$); -#2384=IFCCLASSIFICATIONREFERENCE($,'SL_80_15_04','Aircraft repair spaces',#2382,$,$); -#2385=IFCCLASSIFICATIONREFERENCE($,'SL_80_15_06','Airport control spaces',#2382,$,$); -#2386=IFCCLASSIFICATIONREFERENCE($,'SL_80_15_79','Spacecraft cleaning spaces',#2382,$,$); -#2387=IFCCLASSIFICATIONREFERENCE($,'SL_80_15_81','Spacecraft preparation spaces',#2382,$,$); -#2388=IFCCLASSIFICATIONREFERENCE($,'SL_80_15_82','Spacecraft repair spaces',#2382,$,$); -#2389=IFCCLASSIFICATIONREFERENCE($,'SL_80_20','Cableways',#2355,$,$); -#2390=IFCCLASSIFICATIONREFERENCE($,'SL_80_20_13','Cableways',#2389,$,$); -#2391=IFCCLASSIFICATIONREFERENCE($,'SL_80_30','Cable transport storage and maintenance spaces',#2355,$,$); -#2392=IFCCLASSIFICATIONREFERENCE($,'SL_80_30_34','Gondola repair and cleaning spaces',#2391,$,$); -#2393=IFCCLASSIFICATIONREFERENCE($,'SL_80_30_35','Gondola storage spaces',#2391,$,$); -#2394=IFCCLASSIFICATIONREFERENCE($,'SL_80_35','Road spaces',#2355,$,$); -#2395=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_04','Arrestor beds',#2394,$,$); -#2396=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_08','Bus manoeuvring areas',#2394,$,$); -#2397=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_11','Car manoeuvring areas',#2394,$,$); -#2398=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_13','Carriageways',#2394,$,$); -#2399=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_16','Central reservations',#2394,$,$); -#2400=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_18','Crossover spaces',#2394,$,$); -#2401=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_19','Cycle crossings',#2394,$,$); -#2402=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_20','Cycle lanes',#2394,$,$); -#2403=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_22','Diversion routes',#2394,$,$); -#2404=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_36','Hard shoulders',#2394,$,$); -#2405=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_37','Hard standings',#2394,$,$); -#2406=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_39','Highway pull-offs',#2394,$,$); -#2407=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_40','Highway roundabouts',#2394,$,$); -#2408=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_42','Intersections',#2394,$,$); -#2409=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_44','Junctions',#2394,$,$); -#2410=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_45','Lanes',#2394,$,$); -#2411=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_46','Lay-bys and passing places',#2394,$,$); -#2412=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_57','Non-motorized use crossings',#2394,$,$); -#2413=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_59','Ox-bow laybys',#2394,$,$); -#2414=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_62','Pedestrian crossings',#2394,$,$); -#2415=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_63','Pedestrian routes',#2394,$,$); -#2416=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_64','Pedestrian refuges and islands',#2394,$,$); -#2417=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_66','Police ramps',#2394,$,$); -#2418=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_70','Railway crossings',#2394,$,$); -#2419=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_71','Refuge areas',#2394,$,$); -#2420=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_72','Roadside rest areas',#2394,$,$); -#2421=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_74','Road sections',#2394,$,$); -#2422=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_77','Side reservations',#2394,$,$); -#2423=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_78','Side road carriageways',#2394,$,$); -#2424=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_80','Slip road carriageways',#2394,$,$); -#2425=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_81','Soft shoulders',#2394,$,$); -#2426=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_87','Taxi ranks',#2394,$,$); -#2427=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_90','Truck manoeuvring areas',#2394,$,$); -#2428=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_94','Vaulted spaces',#2394,$,$); -#2429=IFCCLASSIFICATIONREFERENCE($,'SL_80_45','Vehicle storage spaces',#2355,$,$); -#2430=IFCCLASSIFICATIONREFERENCE($,'SL_80_45_09','Bus standing spaces',#2429,$,$); -#2431=IFCCLASSIFICATIONREFERENCE($,'SL_80_45_11','Car park attendant booths',#2429,$,$); -#2432=IFCCLASSIFICATIONREFERENCE($,'SL_80_45_13','Car park ramps',#2429,$,$); -#2433=IFCCLASSIFICATIONREFERENCE($,'SL_80_45_15','Cycle parking spaces',#2429,$,$); -#2434=IFCCLASSIFICATIONREFERENCE($,'SL_80_45_40','Indoor vehicle parking spaces',#2429,$,$); -#2435=IFCCLASSIFICATIONREFERENCE($,'SL_80_45_59','Outdoor vehicle parking spaces',#2429,$,$); -#2436=IFCCLASSIFICATIONREFERENCE($,'SL_80_45_91','Truck standing spaces',#2429,$,$); -#2437=IFCCLASSIFICATIONREFERENCE($,'SL_80_50','Railway spaces',#2355,$,$); -#2438=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_11','Carriage cleaning spaces',#2437,$,$); -#2439=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_24','Double sided platforms',#2437,$,$); -#2440=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_26','Engine fuelling areas',#2437,$,$); -#2441=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_27','Engine inspection pits',#2437,$,$); -#2442=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_28','Engine servicing areas',#2437,$,$); -#2443=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_29','Engine wash areas',#2437,$,$); -#2444=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_47','Light rail stops',#2437,$,$); -#2445=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_50','Marshalling yards',#2437,$,$); -#2446=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_58','Railway overpasses',#2437,$,$); -#2447=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_70','Rail repair spaces',#2437,$,$); -#2448=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_71','Railway side reservations',#2437,$,$); -#2449=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_72','Railway lines',#2437,$,$); -#2450=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_74','Railway sections',#2437,$,$); -#2451=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_77','Railway signal control spaces',#2437,$,$); -#2452=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_79','Signalling equipment room',#2437,$,$); -#2453=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_80','Single sided platforms',#2437,$,$); -#2454=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_85','Stabling yards',#2437,$,$); -#2455=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_88','Track paralleling huts',#2437,$,$); -#2456=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_90','Train stops',#2437,$,$); -#2457=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_92','Railway underpasses',#2437,$,$); -#2458=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_95','Wagon decontamination spaces',#2437,$,$); -#2459=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_97','Wagon maintenance spaces',#2437,$,$); -#2460=IFCCLASSIFICATIONREFERENCE($,'SL_80_70','Marine and waterways transport spaces',#2355,$,$); -#2461=IFCCLASSIFICATIONREFERENCE($,'SL_80_70_11','Canal lock chambers',#2460,$,$); -#2462=IFCCLASSIFICATIONREFERENCE($,'SL_80_70_37','Harbour locks',#2460,$,$); -#2463=IFCCLASSIFICATIONREFERENCE($,'SL_80_90','Transport hubs',#2355,$,$); -#2464=IFCCLASSIFICATIONREFERENCE($,'SL_80_92','Grid systems',#2355,$,$); -#2465=IFCCLASSIFICATIONREFERENCE($,'SL_80_92_34','Geospatial grids',#2464,$,$); -#2466=IFCCLASSIFICATIONREFERENCE($,'SL_80_92_37','Horizontal alignment grids',#2464,$,$); -#2467=IFCCLASSIFICATIONREFERENCE($,'SL_80_92_94','Vertical alignment grids',#2464,$,$); -#2468=IFCCLASSIFICATIONREFERENCE($,'SL_80_94','Bridge and structure spaces',#2355,$,$); -#2469=IFCCLASSIFICATIONREFERENCE($,'SL_80_94_07','Bearing shelves',#2468,$,$); -#2470=IFCCLASSIFICATIONREFERENCE($,'SL_80_94_09','Bridge aprons',#2468,$,$); -#2471=IFCCLASSIFICATIONREFERENCE($,'SL_80_94_71','Retaining wall aprons',#2468,$,$); -#2472=IFCCLASSIFICATIONREFERENCE($,'SL_80_96','Tunnel and shaft spaces',#2355,$,$); -#2473=IFCCLASSIFICATIONREFERENCE($,'SL_80_96_15','Concourse tunnels',#2472,$,$); -#2474=IFCCLASSIFICATIONREFERENCE($,'SL_80_96_18','Crossover tunnels',#2472,$,$); -#2475=IFCCLASSIFICATIONREFERENCE($,'SL_80_96_20','Drift tunnel portals',#2472,$,$); -#2476=IFCCLASSIFICATIONREFERENCE($,'SL_80_96_58','Overrun tunnels',#2472,$,$); -#2477=IFCCLASSIFICATIONREFERENCE($,'SL_80_96_60','Passageway tunnels',#2472,$,$); -#2478=IFCCLASSIFICATIONREFERENCE($,'SL_80_96_64','Platform tunnels',#2472,$,$); -#2479=IFCCLASSIFICATIONREFERENCE($,'SL_80_96_78','Sidings tunnels',#2472,$,$); -#2480=IFCCLASSIFICATIONREFERENCE($,'SL_80_98','Transport kinematic envelopes',#2355,$,$); -#2481=IFCCLASSIFICATIONREFERENCE($,'SL_80_98_09','Bridge headrooms',#2480,$,$); -#2482=IFCCLASSIFICATIONREFERENCE($,'SL_80_98_15','Collapse radius',#2480,$,$); -#2483=IFCCLASSIFICATIONREFERENCE($,'SL_80_98_46','Lateral safety zones',#2480,$,$); -#2484=IFCCLASSIFICATIONREFERENCE($,'SL_80_98_48','Longitudinal safety zones',#2480,$,$); -#2485=IFCCLASSIFICATIONREFERENCE($,'SL_80_98_75','Safety clearance zones',#2480,$,$); -#2486=IFCCLASSIFICATIONREFERENCE($,'SL_80_98_85','Swept path areas',#2480,$,$); -#2487=IFCCLASSIFICATIONREFERENCE($,'SL_80_98_90','Tunnel headrooms',#2480,$,$); -#2488=IFCCLASSIFICATIONREFERENCE($,'SL_80_98_97','Working widths',#2480,$,$); -#2489=IFCCLASSIFICATIONREFERENCE($,'SL_90','General spaces',#1765,$,$); -#2490=IFCCLASSIFICATIONREFERENCE($,'SL_90_10','Circulation spaces',#2489,$,$); -#2491=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_02','Air locks',#2490,$,$); -#2492=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_04','Atriums',#2490,$,$); -#2493=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_08','Breezeways',#2490,$,$); -#2494=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_15','Corridors',#2490,$,$); -#2495=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_16','Covered walkways and internal bridges',#2490,$,$); -#2496=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_24','Drop-off and collection areas',#2490,$,$); -#2497=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_27','Entrance halls',#2490,$,$); -#2498=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_28','Escalators and travellators',#2490,$,$); -#2499=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_34','Goods conveyors',#2490,$,$); -#2500=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_36','Hallways',#2490,$,$); -#2501=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_46','Landings',#2490,$,$); -#2502=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_47','Lifts',#2490,$,$); -#2503=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_51','Lobbies',#2490,$,$); -#2504=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_64','Porches',#2490,$,$); -#2505=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_68','Public squares',#2490,$,$); -#2506=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_71','Retail circulation spaces',#2490,$,$); -#2507=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_77','Shelters',#2490,$,$); -#2508=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_87','Stairways',#2490,$,$); -#2509=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_94','Vestibules',#2490,$,$); -#2510=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_95','Walkways',#2490,$,$); -#2511=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_96','Wheelchair circulation spaces',#2490,$,$); -#2512=IFCCLASSIFICATIONREFERENCE($,'SL_90_20','Common spaces',#2489,$,$); -#2513=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_01','Accident and emergency waiting rooms',#2512,$,$); -#2514=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_02','Air spaces',#2512,$,$); -#2515=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_04','Audience seating areas',#2512,$,$); -#2516=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_05','Audience standing areas',#2512,$,$); -#2517=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_08','Breakout spaces',#2512,$,$); -#2518=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_13','Changing rooms',#2512,$,$); -#2519=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_14','Cloakrooms',#2512,$,$); -#2520=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_15','Corporate boxes and VIP seating',#2512,$,$); -#2521=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_16','Customer service counter areas',#2512,$,$); -#2522=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_69','Queuing areas',#2512,$,$); -#2523=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_82','Spectator seating areas',#2512,$,$); -#2524=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_83','Spectator standing areas',#2512,$,$); -#2525=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_88','Temporary seating areas',#2512,$,$); -#2526=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_89','Ticket offices',#2512,$,$); -#2527=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_96','Waiting rooms',#2512,$,$); -#2528=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_98','Work booths',#2512,$,$); -#2529=IFCCLASSIFICATIONREFERENCE($,'SL_90_30','Construction voids',#2489,$,$); -#2530=IFCCLASSIFICATIONREFERENCE($,'SL_90_30_25','Excavation volumes',#2529,$,$); -#2531=IFCCLASSIFICATIONREFERENCE($,'SL_90_30_30','Finishes allowances',#2529,$,$); -#2532=IFCCLASSIFICATIONREFERENCE($,'SL_90_30_80','Space proofing envelopes',#2529,$,$); -#2533=IFCCLASSIFICATIONREFERENCE($,'SL_90_30_90','Tolerance zones',#2529,$,$); -#2534=IFCCLASSIFICATIONREFERENCE($,'SL_90_40','General levels',#2489,$,$); -#2535=IFCCLASSIFICATIONREFERENCE($,'SL_90_40_46','Levels',#2534,$,$); -#2536=IFCCLASSIFICATIONREFERENCE($,'SL_90_50','Storage spaces',#2489,$,$); -#2537=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_04','Arms depots and armouries',#2536,$,$); -#2538=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_06','Baggage storage areas',#2536,$,$); -#2539=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_07','Battery stores',#2536,$,$); -#2540=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_08','Blood banks',#2536,$,$); -#2541=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_09','Boat storage spaces',#2536,$,$); -#2542=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_11','Cargo storage areas',#2536,$,$); -#2543=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_12','Car ports',#2536,$,$); -#2544=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_13','Chemicals stores',#2536,$,$); -#2545=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_14','Clothes stores',#2536,$,$); -#2546=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_15','Cold stores',#2536,$,$); -#2547=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_17','Cycle storage spaces',#2536,$,$); -#2548=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_24','Dry waste storage spaces',#2536,$,$); -#2549=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_25','Dungsteads',#2536,$,$); -#2550=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_26','Effluent tanks',#2536,$,$); -#2551=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_27','Equipment stores',#2536,$,$); -#2552=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_28','Explosives and ordnance storerooms',#2536,$,$); -#2553=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_30','Feed stores',#2536,$,$); -#2554=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_31','Flammable chemical stores',#2536,$,$); -#2555=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_32','Fuel storage areas',#2536,$,$); -#2556=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_33','Garages',#2536,$,$); -#2557=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_34','Gas storage spaces',#2536,$,$); -#2558=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_35','General storerooms',#2536,$,$); -#2559=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_36','Goods stores',#2536,$,$); -#2560=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_37','Grain stores',#2536,$,$); -#2561=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_38','Hazardous waste storage spaces',#2536,$,$); -#2562=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_44','Janitor stores',#2536,$,$); -#2563=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_45','Keg stores',#2536,$,$); -#2564=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_46','Larders and pantries',#2536,$,$); -#2565=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_47','Left luggage stores',#2536,$,$); -#2566=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_48','Locker rooms',#2536,$,$); -#2567=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_52','Mineral storage spaces',#2536,$,$); -#2568=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_54','Morgues',#2536,$,$); -#2569=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_55','Mortuaries',#2536,$,$); -#2570=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_58','Oil storage spaces',#2536,$,$); -#2571=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_65','Pharmaceutical stores',#2536,$,$); -#2572=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_70','Raw materials storage silos',#2536,$,$); -#2573=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_71','Raw materials storage spaces',#2536,$,$); -#2574=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_72','Raw materials storage tanks',#2536,$,$); -#2575=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_77','Secure storerooms',#2536,$,$); -#2576=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_80','Solid fuel storerooms',#2536,$,$); -#2577=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_84','Storage rooms',#2536,$,$); -#2578=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_88','Tissue and organ stores',#2536,$,$); -#2579=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_90','Vaults and strong rooms',#2536,$,$); -#2580=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_93','Walk-in wardrobes',#2536,$,$); -#2581=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_94','Waste gas storage spaces',#2536,$,$); -#2582=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_95','Waste liquids storage spaces',#2536,$,$); -#2583=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_96','Waste solids storage spaces',#2536,$,$); -#2584=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_97','Wet waste storage spaces',#2536,$,$); -#2585=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_98','Wine cellars',#2536,$,$); -#2586=IFCCLASSIFICATIONREFERENCE($,'SL_90_60','Unoccupied voids',#2489,$,$); -#2587=IFCCLASSIFICATIONREFERENCE($,'SL_90_60_01','Access spaces',#2586,$,$); -#2588=IFCCLASSIFICATIONREFERENCE($,'SL_90_60_02','Air shafts',#2586,$,$); -#2589=IFCCLASSIFICATIONREFERENCE($,'SL_90_60_10','Cavities',#2586,$,$); -#2590=IFCCLASSIFICATIONREFERENCE($,'SL_90_60_12','Chimneys',#2586,$,$); -#2591=IFCCLASSIFICATIONREFERENCE($,'SL_90_60_13','Chutes',#2586,$,$); -#2592=IFCCLASSIFICATIONREFERENCE($,'SL_90_60_18','Crawl spaces',#2586,$,$); -#2593=IFCCLASSIFICATIONREFERENCE($,'SL_90_60_49','Lift pits',#2586,$,$); -#2594=IFCCLASSIFICATIONREFERENCE($,'SL_90_60_50','Lift shafts',#2586,$,$); -#2595=IFCCLASSIFICATIONREFERENCE($,'SL_90_60_51','Light wells',#2586,$,$); -#2596=IFCCLASSIFICATIONREFERENCE($,'SL_90_60_64','Platform voids',#2586,$,$); -#2597=IFCCLASSIFICATIONREFERENCE($,'SL_90_60_72','Roof surface spaces',#2586,$,$); -#2598=IFCCLASSIFICATIONREFERENCE($,'SL_90_60_74','Roof voids',#2586,$,$); -#2599=IFCCLASSIFICATIONREFERENCE($,'SL_90_90','Plant and control spaces',#2489,$,$); -#2600=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_01','Access floor voids',#2599,$,$); -#2601=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_08','Boiler rooms',#2599,$,$); -#2602=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_13','Ceiling voids',#2599,$,$); -#2603=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_15','Control rooms',#2599,$,$); -#2604=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_32','Furnace rooms',#2599,$,$); -#2605=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_42','Incinerator rooms',#2599,$,$); -#2606=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_48','Lift machine rooms',#2599,$,$); -#2607=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_64','Plant rooms',#2599,$,$); -#2608=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_77','Server rooms',#2599,$,$); -#2609=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_78','Services shafts',#2599,$,$); -#2610=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_85','Switch rooms',#2599,$,$); -#2611=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_87','Tank rooms',#2599,$,$); -#2612=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_90','Transformer rooms',#2599,$,$); -#2613=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_96','Wall services voids',#2599,$,$); -#2614=IFCCLASSIFICATIONREFERENCE($,'EF','Elements/ functions',#1,$,$); -#2615=IFCCLASSIFICATIONREFERENCE($,'EF_15','Site elements',#2614,$,$); -#2616=IFCCLASSIFICATIONREFERENCE($,'EF_15_15','Construction sites',#2615,$,$); -#2617=IFCCLASSIFICATIONREFERENCE($,'EF_15_95','Work areas',#2615,$,$); -#2618=IFCCLASSIFICATIONREFERENCE($,'EF_20','Structural elements',#2614,$,$); -#2619=IFCCLASSIFICATIONREFERENCE($,'EF_20_05','Substructure',#2618,$,$); -#2620=IFCCLASSIFICATIONREFERENCE($,'EF_20_10','Superstructure',#2618,$,$); -#2621=IFCCLASSIFICATIONREFERENCE($,'EF_20_50','Bridge abutments and piers',#2618,$,$); -#2622=IFCCLASSIFICATIONREFERENCE($,'EF_25','Wall and barrier elements',#2614,$,$); -#2623=IFCCLASSIFICATIONREFERENCE($,'EF_25_10','Walls',#2622,$,$); -#2624=IFCCLASSIFICATIONREFERENCE($,'EF_25_30','Doors and windows',#2622,$,$); -#2625=IFCCLASSIFICATIONREFERENCE($,'EF_25_55','Barriers',#2622,$,$); -#2626=IFCCLASSIFICATIONREFERENCE($,'EF_30','Roofs, floor and paving elements',#2614,$,$); -#2627=IFCCLASSIFICATIONREFERENCE($,'EF_30_10','Roofs',#2626,$,$); -#2628=IFCCLASSIFICATIONREFERENCE($,'EF_30_20','Floors',#2626,$,$); -#2629=IFCCLASSIFICATIONREFERENCE($,'EF_30_60','Pavements',#2626,$,$); -#2630=IFCCLASSIFICATIONREFERENCE($,'EF_30_70','Bridge decks',#2626,$,$); -#2631=IFCCLASSIFICATIONREFERENCE($,'EF_35','Stairs and ramps',#2614,$,$); -#2632=IFCCLASSIFICATIONREFERENCE($,'EF_35_10','Stairs',#2631,$,$); -#2633=IFCCLASSIFICATIONREFERENCE($,'EF_35_20','Ramps',#2631,$,$); -#2634=IFCCLASSIFICATIONREFERENCE($,'EF_37','Tunnel, vessel and tower elements',#2614,$,$); -#2635=IFCCLASSIFICATIONREFERENCE($,'EF_37_16','Vessels and trenches',#2634,$,$); -#2636=IFCCLASSIFICATIONREFERENCE($,'EF_37_17','Towers, chimneys and masts',#2634,$,$); -#2637=IFCCLASSIFICATIONREFERENCE($,'EF_37_50','Tunnels and shafts',#2634,$,$); -#2638=IFCCLASSIFICATIONREFERENCE($,'EF_40','Signage, fittings, furnishings and equipment',#2614,$,$); -#2639=IFCCLASSIFICATIONREFERENCE($,'EF_40_10','Signage',#2638,$,$); -#2640=IFCCLASSIFICATIONREFERENCE($,'EF_40_20','Fittings',#2638,$,$); -#2641=IFCCLASSIFICATIONREFERENCE($,'EF_40_30','Furnishings',#2638,$,$); -#2642=IFCCLASSIFICATIONREFERENCE($,'EF_40_40','Equipment',#2638,$,$); -#2643=IFCCLASSIFICATIONREFERENCE($,'EF_45','Flora and fauna elements',#2614,$,$); -#2644=IFCCLASSIFICATIONREFERENCE($,'EF_45_10','Planted elements',#2643,$,$); -#2645=IFCCLASSIFICATIONREFERENCE($,'EF_45_20','Grassed elements',#2643,$,$); -#2646=IFCCLASSIFICATIONREFERENCE($,'EF_45_30','Fauna elements',#2643,$,$); -#2647=IFCCLASSIFICATIONREFERENCE($,'EF_45_75','Fish and eel pass elements',#2643,$,$); -#2648=IFCCLASSIFICATIONREFERENCE($,'EF_50','Waste disposal functions',#2614,$,$); -#2649=IFCCLASSIFICATIONREFERENCE($,'EF_50_10','Gas waste collection',#2648,$,$); -#2650=IFCCLASSIFICATIONREFERENCE($,'EF_50_20','Wet waste collection',#2648,$,$); -#2651=IFCCLASSIFICATIONREFERENCE($,'EF_50_30','Drainage collection',#2648,$,$); -#2652=IFCCLASSIFICATIONREFERENCE($,'EF_50_40','Dry waste collection',#2648,$,$); -#2653=IFCCLASSIFICATIONREFERENCE($,'EF_50_50','Gas waste treatment and disposal',#2648,$,$); -#2654=IFCCLASSIFICATIONREFERENCE($,'EF_50_60','Wet waste treatment and disposal',#2648,$,$); -#2655=IFCCLASSIFICATIONREFERENCE($,'EF_50_70','Drainage treatment and disposal',#2648,$,$); -#2656=IFCCLASSIFICATIONREFERENCE($,'EF_50_75','Wastewater treatment and disposal',#2648,$,$); -#2657=IFCCLASSIFICATIONREFERENCE($,'EF_50_80','Dry waste treatment and disposal',#2648,$,$); -#2658=IFCCLASSIFICATIONREFERENCE($,'EF_55','Piped supply functions',#2614,$,$); -#2659=IFCCLASSIFICATIONREFERENCE($,'EF_55_05','Gas extraction and treatment',#2658,$,$); -#2660=IFCCLASSIFICATIONREFERENCE($,'EF_55_10','Liquid fuel extraction and treatment',#2658,$,$); -#2661=IFCCLASSIFICATIONREFERENCE($,'EF_55_15','Water extraction and treatment',#2658,$,$); -#2662=IFCCLASSIFICATIONREFERENCE($,'EF_55_20','Gas supply',#2658,$,$); -#2663=IFCCLASSIFICATIONREFERENCE($,'EF_55_30','Fire extinguishing supply',#2658,$,$); -#2664=IFCCLASSIFICATIONREFERENCE($,'EF_55_40','Steam supply',#2658,$,$); -#2665=IFCCLASSIFICATIONREFERENCE($,'EF_55_50','Liquid fuel supply',#2658,$,$); -#2666=IFCCLASSIFICATIONREFERENCE($,'EF_55_60','Process liquid supply',#2658,$,$); -#2667=IFCCLASSIFICATIONREFERENCE($,'EF_55_70','Water supply',#2658,$,$); -#2668=IFCCLASSIFICATIONREFERENCE($,'EF_55_90','Piped solids supply',#2658,$,$); -#2669=IFCCLASSIFICATIONREFERENCE($,'EF_60','Heating, cooling and refrigeration functions',#2614,$,$); -#2670=IFCCLASSIFICATIONREFERENCE($,'EF_60_30','Rail and paving heating',#2669,$,$); -#2671=IFCCLASSIFICATIONREFERENCE($,'EF_60_40','Space heating and cooling',#2669,$,$); -#2672=IFCCLASSIFICATIONREFERENCE($,'EF_60_60','Refrigeration',#2669,$,$); -#2673=IFCCLASSIFICATIONREFERENCE($,'EF_60_80','Drying',#2669,$,$); -#2674=IFCCLASSIFICATIONREFERENCE($,'EF_65','Ventilation and air conditioning functions',#2614,$,$); -#2675=IFCCLASSIFICATIONREFERENCE($,'EF_65_40','Ventilation',#2674,$,$); -#2676=IFCCLASSIFICATIONREFERENCE($,'EF_65_80','Air conditioning',#2674,$,$); -#2677=IFCCLASSIFICATIONREFERENCE($,'EF_70','Electrical power and lighting functions',#2614,$,$); -#2678=IFCCLASSIFICATIONREFERENCE($,'EF_70_10','Electrical power generation',#2677,$,$); -#2679=IFCCLASSIFICATIONREFERENCE($,'EF_70_30','Electricity distribution and transmission',#2677,$,$); -#2680=IFCCLASSIFICATIONREFERENCE($,'EF_70_80','Lighting',#2677,$,$); -#2681=IFCCLASSIFICATIONREFERENCE($,'EF_75','Communications, security, safety and protection functions',#2614,$,$); -#2682=IFCCLASSIFICATIONREFERENCE($,'EF_75_10','Communication',#2681,$,$); -#2683=IFCCLASSIFICATIONREFERENCE($,'EF_75_30','Signalling',#2681,$,$); -#2684=IFCCLASSIFICATIONREFERENCE($,'EF_75_40','Security',#2681,$,$); -#2685=IFCCLASSIFICATIONREFERENCE($,'EF_75_50','Safety and protection',#2681,$,$); -#2686=IFCCLASSIFICATIONREFERENCE($,'EF_75_60','Environmental safety',#2681,$,$); -#2687=IFCCLASSIFICATIONREFERENCE($,'EF_75_70','Control and management',#2681,$,$); -#2688=IFCCLASSIFICATIONREFERENCE($,'EF_75_80','Protection',#2681,$,$); -#2689=IFCCLASSIFICATIONREFERENCE($,'EF_80','Transport functions',#2614,$,$); -#2690=IFCCLASSIFICATIONREFERENCE($,'EF_80_10','Cable transport',#2689,$,$); -#2691=IFCCLASSIFICATIONREFERENCE($,'EF_80_20','Conveyors',#2689,$,$); -#2692=IFCCLASSIFICATIONREFERENCE($,'EF_80_30','Cranes and hoists',#2689,$,$); -#2693=IFCCLASSIFICATIONREFERENCE($,'EF_80_50','Lifts',#2689,$,$); -#2694=IFCCLASSIFICATIONREFERENCE($,'EF_80_70','Rail tracks',#2689,$,$); -#2695=IFCCLASSIFICATIONREFERENCE($,'Ss','Systems',#1,$,$); -#2696=IFCCLASSIFICATIONREFERENCE($,'Ss_15','Earthworks, remediation and temporary systems',#2695,$,$); -#2697=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10','Groundworks and earthworks systems',#2696,$,$); -#2698=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_30','Excavating and filling systems',#2697,$,$); -#2699=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_30_05','Backfill systems',#2698,$,$); -#2700=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_30_25','Earthworks excavating systems',#2698,$,$); -#2701=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_30_27','Earthworks filling systems',#2698,$,$); -#2702=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_30_29','Earthworks filling systems around trees',#2698,$,$); -#2703=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_30_31','Earthworks filling systems behind retaining walls',#2698,$,$); -#2704=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_30_65','Puddled clay lining systems',#2698,$,$); -#2705=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_30_90','Topsoil filling systems',#2698,$,$); -#2706=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_33','Ground gas disposal systems',#2697,$,$); -#2707=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_33_34','Ground gas collection and venting systems',#2706,$,$); -#2708=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_35','Ground remediation systems',#2697,$,$); -#2709=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_35_07','Bioremediation systems',#2708,$,$); -#2710=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_45','Landfill systems',#2697,$,$); -#2711=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_76','Site waste disposal systems',#2697,$,$); -#2712=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_76_21','Dewatering systems',#2711,$,$); -#2713=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_78','Slurry wall systems',#2697,$,$); -#2714=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_80','Stabilization systems',#2697,$,$); -#2715=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_80_33','Erosion control systems',#2714,$,$); -#2716=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_80_70','Rock bolting and dowelling systems',#2714,$,$); -#2717=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_80_80','Soil nailing systems',#2714,$,$); -#2718=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_80_85','Subterranean void filling systems',#2714,$,$); -#2719=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30','Remediation, repair and renovation systems',#2696,$,$); -#2720=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_10','Building services remediation systems',#2719,$,$); -#2721=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_12','Ceramics repair and renovation systems',#2719,$,$); -#2722=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_15','Concrete and masonry cleaning systems',#2719,$,$); -#2723=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_15_15','Concrete cleaning systems',#2722,$,$); -#2724=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_15_50','Masonry cleaning systems',#2722,$,$); -#2725=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_15_65','Preliminary concrete cleaning systems',#2722,$,$); -#2726=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_15_66','Preliminary masonry cleaning systems',#2722,$,$); -#2727=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_17','Concrete repair and renovation systems',#2719,$,$); -#2728=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_17_10','Bonded steel plate repair systems',#2727,$,$); -#2729=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_17_12','Concrete crack repair or filling systems',#2727,$,$); -#2730=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_17_14','Concrete mortar or overlay systems',#2727,$,$); -#2731=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_17_16','Concrete protective coating systems',#2727,$,$); -#2732=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_17_18','Concrete repair systems',#2727,$,$); -#2733=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_17_85','Sprayed concrete repair systems',#2727,$,$); -#2734=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_32','Fungus and beetle eradication systems',#2719,$,$); -#2735=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_32_05','Beetle eradication systems',#2734,$,$); -#2736=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_32_15','Combined fungus and beetle treatment systems',#2734,$,$); -#2737=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_32_35','Hot air infestation treatment systems',#2734,$,$); -#2738=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_32_50','Masonry fungus treatment systems',#2734,$,$); -#2739=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_32_85','Termite treatment systems',#2734,$,$); -#2740=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_32_90','Timber fungus treatment systems',#2734,$,$); -#2741=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_33','Glass repair and renovation systems',#2719,$,$); -#2742=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_50','Masonry repair and renovation systems',#2719,$,$); -#2743=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_50_11','Cavity wall insulation systems',#2742,$,$); -#2744=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_50_50','Masonry repair systems',#2742,$,$); -#2745=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_50_53','Mortar joint repair systems',#2742,$,$); -#2746=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_50_55','Mortar repointing systems',#2742,$,$); -#2747=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_52','Metal repair and renovation systems',#2719,$,$); -#2748=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_52_03','Aluminium repair systems',#2747,$,$); -#2749=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_52_15','Copper repair systems',#2747,$,$); -#2750=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_52_42','Iron repair systems',#2747,$,$); -#2751=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_52_46','Lead repair systems',#2747,$,$); -#2752=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_52_84','Steel repair systems',#2747,$,$); -#2753=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_65','Pipeline renovation systems',#2719,$,$); -#2754=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_65_15','Close fit plastics pipe lining systems',#2753,$,$); -#2755=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_65_17','Continuous plastics pipe lining systems',#2753,$,$); -#2756=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_65_20','Cured in place lining systems',#2753,$,$); -#2757=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_65_65','Preformed lining systems',#2753,$,$); -#2758=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_65_72','Rigidly anchored plastics inner layer (RAPL) lining systems',#2753,$,$); -#2759=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_65_80','Spray lining systems',#2753,$,$); -#2760=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_65_81','Spirally wound plastics pipe lining systems',#2753,$,$); -#2761=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_90','Timber repair and renovation systems',#2719,$,$); -#2762=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_90_82','Timber end lap repair systems',#2761,$,$); -#2763=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_90_84','Timber joint strengthening systems',#2761,$,$); -#2764=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_90_86','Timber section repair external splice systems',#2761,$,$); -#2765=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_90_88','Timber section repair internal reinforcement systems',#2761,$,$); -#2766=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_90_90','Timber section strengthening external reinforcement systems',#2761,$,$); -#2767=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_90_92','Timber section strengthening internal reinforcement systems',#2761,$,$); -#2768=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95','Temporary works systems',#2696,$,$); -#2769=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_15','Temporary preparatory works systems',#2768,$,$); -#2770=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_15_10','Borehole systems',#2769,$,$); -#2771=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_17','Temporary protection systems',#2768,$,$); -#2772=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_17_90','Temporary backfill systems',#2771,$,$); -#2773=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_20','Temporary whole entity structural works systems',#2768,$,$); -#2774=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_20_30','Flying shores systems',#2773,$,$); -#2775=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_20_32','Framed retention structure systems',#2773,$,$); -#2776=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_20_70','Raking shores systems',#2773,$,$); -#2777=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_20_72','Retention structure systems',#2773,$,$); -#2778=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_20_75','Scaffold retention structure systems',#2773,$,$); -#2779=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_20_87','Thrust pit systems',#2773,$,$); -#2780=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_25','Temporary wall and barrier works systems',#2768,$,$); -#2781=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_30','Temporary roof, floor and paving works systems',#2768,$,$); -#2782=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_32','Temporary water and land management systems',#2768,$,$); -#2783=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_32_85','Sedimentation ponds',#2782,$,$); -#2784=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_35','Temporary fixed access, tunnel, shaft, vessel and tower works systems',#2768,$,$); -#2785=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_40','Temporary signage and fittings, furnishings and equipment (FF&E) works systems',#2768,$,$); -#2786=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_45','Temporary flora and fauna systems',#2768,$,$); -#2787=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_45_42','Intercropping systems',#2786,$,$); -#2788=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_45_85','Spoil heap temporary crop systems',#2786,$,$); -#2789=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_45_90','Topsoil heap temporary crop systems',#2786,$,$); -#2790=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_55','Temporary piped supply works systems',#2768,$,$); -#2791=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_55_90','Tunnelling compressed air systems',#2790,$,$); -#2792=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_60','Temporary heating, cooling and refrigeration works systems',#2768,$,$); -#2793=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_65','Temporary ventilation and air conditioning works systems',#2768,$,$); -#2794=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_70','Temporary electrical works systems',#2768,$,$); -#2795=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_75','Temporary communications, security, safety, control and protection works systems',#2768,$,$); -#2796=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_80','Temporary pavement works systems',#2768,$,$); -#2797=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_80_02','Temporary access road systems',#2796,$,$); -#2798=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_80_72','Temporary roadwork systems',#2796,$,$); -#2799=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_85','Temporary process engineering works systems',#2768,$,$); -#2800=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_90','Temporary soft facility management works services',#2768,$,$); -#2801=IFCCLASSIFICATIONREFERENCE($,'Ss_20','Structural systems',#2695,$,$); -#2802=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05','Substructure systems',#2801,$,$); -#2803=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_15','Concrete foundation systems',#2802,$,$); -#2804=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_15_65','Precast concrete pad and strip foundation systems',#2803,$,$); -#2805=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_15_70','Reinforced concrete pad and strip foundation systems',#2803,$,$); -#2806=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_15_71','Reinforced concrete pilecap and ground beam foundation systems',#2803,$,$); -#2807=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_15_72','Reinforced concrete raft foundation systems',#2803,$,$); -#2808=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_15_80','Steel ground beam foundation systems',#2803,$,$); -#2809=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_15_90','Unreinforced concrete foundation systems for cast in products',#2803,$,$); -#2810=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_15_91','Unreinforced concrete pad and strip foundation systems',#2803,$,$); -#2811=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_15_92','Unreinforced concrete trench fill foundation systems',#2803,$,$); -#2812=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_50','Minor concrete substructure systems',#2802,$,$); -#2813=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_50_15','Concrete haunching systems',#2812,$,$); -#2814=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_50_65','Precast concrete foundation and plinth systems',#2812,$,$); -#2815=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_50_70','Reinforced concrete base or foundation systems',#2812,$,$); -#2816=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_50_92','Unreinforced concrete foundation with cast in products systems',#2812,$,$); -#2817=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_50_93','Unreinforced concrete foundation and plinth systems',#2812,$,$); -#2818=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_65','Piling systems',#2802,$,$); -#2819=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_65_24','Driven precast or prestressed concrete piling systems',#2818,$,$); -#2820=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_65_40','In situ concrete augered piling systems',#2818,$,$); -#2821=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_65_41','In situ concrete bored piling systems',#2818,$,$); -#2822=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_65_42','In situ concrete cased displacement piling systems',#2818,$,$); -#2823=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_65_43','In situ concrete displacement piling systems',#2818,$,$); -#2824=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_65_44','In situ concrete mini-piling or micro-piling systems',#2818,$,$); -#2825=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_65_64','Plunge column piling systems',#2818,$,$); -#2826=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_65_76','Screw piling systems',#2818,$,$); -#2827=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_65_84','Steel bearing pile systems',#2818,$,$); -#2828=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_65_89','Timber piling systems',#2818,$,$); -#2829=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_80','Structural grouting systems',#2802,$,$); -#2830=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_80_12','Cementitious grout systems',#2829,$,$); -#2831=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_80_57','Non-cementitious grout systems',#2829,$,$); -#2832=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_80_71','Retaining wall cementitious grout systems',#2829,$,$); -#2833=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_80_73','Retaining wall self-hardening slurry systems',#2829,$,$); -#2834=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_90','Underpinning systems',#2802,$,$); -#2835=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_90_10','Beam and pier unreinforced concrete underpinning systems',#2834,$,$); -#2836=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_90_35','Grouted underpinning systems',#2834,$,$); -#2837=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_90_45','Jacked pile underpinning systems',#2834,$,$); -#2838=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_90_46','Jet grouted underpinning systems',#2834,$,$); -#2839=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_90_50','Mass concrete underpinning systems',#2834,$,$); -#2840=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_90_60','Pile and cantilever support underpinning systems',#2834,$,$); -#2841=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_90_61','Pile and needle underpinning systems',#2834,$,$); -#2842=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_90_70','Raking pile underpinning systems',#2834,$,$); -#2843=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10','Structural frame systems',#2801,$,$); -#2844=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_30','Bridge structure systems',#2843,$,$); -#2845=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_30_30','Footbridge systems',#2844,$,$); -#2846=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_30_65','Pipe bridge systems',#2844,$,$); -#2847=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_60','Prefabricated framed and panelled structures',#2843,$,$); -#2848=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_60_34','Glazed structural systems',#2847,$,$); -#2849=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_60_60','Panelled and framed structural systems',#2847,$,$); -#2850=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_60_84','Structural insulated panel systems',#2847,$,$); -#2851=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_65','Prefabricated room systems',#2843,$,$); -#2852=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_65_15','Composite pods',#2851,$,$); -#2853=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_65_17','Concrete pods',#2851,$,$); -#2854=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_65_65','Polypropylene pods',#2851,$,$); -#2855=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_70','Shelter systems',#2843,$,$); -#2856=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_70_03','Animal shelter systems',#2855,$,$); -#2857=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_70_62','People shelter systems',#2855,$,$); -#2858=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_70_64','Plant shelter systems',#2855,$,$); -#2859=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_70_84','Storage shelter systems',#2855,$,$); -#2860=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_75','Structural framing systems',#2843,$,$); -#2861=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_75_15','Concrete framing systems',#2860,$,$); -#2862=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_75_35','Heavy steel framing systems',#2860,$,$); -#2863=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_75_45','Light steel framing systems',#2860,$,$); -#2864=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_75_65','Precast reinforced concrete framing systems',#2860,$,$); -#2865=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_75_70','In situ reinforced concrete framing systems',#2860,$,$); -#2866=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_75_85','Timber framing systems',#2860,$,$); -#2867=IFCCLASSIFICATIONREFERENCE($,'Ss_20_20','Structural beams',#2801,$,$); -#2868=IFCCLASSIFICATIONREFERENCE($,'Ss_20_20_75','Structural beam systems',#2867,$,$); -#2869=IFCCLASSIFICATIONREFERENCE($,'Ss_20_20_75_15','Concrete beam systems',#2868,$,$); -#2870=IFCCLASSIFICATIONREFERENCE($,'Ss_20_20_75_80','Steel beam systems',#2868,$,$); -#2871=IFCCLASSIFICATIONREFERENCE($,'Ss_20_20_75_85','Timber beam systems',#2868,$,$); -#2872=IFCCLASSIFICATIONREFERENCE($,'Ss_20_30','Structural columns',#2801,$,$); -#2873=IFCCLASSIFICATIONREFERENCE($,'Ss_20_30_75','Structural column systems',#2872,$,$); -#2874=IFCCLASSIFICATIONREFERENCE($,'Ss_20_30_75_15','Concrete column systems',#2873,$,$); -#2875=IFCCLASSIFICATIONREFERENCE($,'Ss_20_30_75_50','Masonry column systems',#2873,$,$); -#2876=IFCCLASSIFICATIONREFERENCE($,'Ss_20_30_75_80','Steel column systems',#2873,$,$); -#2877=IFCCLASSIFICATIONREFERENCE($,'Ss_20_30_75_85','Timber column systems',#2873,$,$); -#2878=IFCCLASSIFICATIONREFERENCE($,'Ss_20_40','Structural sheet and cable systems',#2801,$,$); -#2879=IFCCLASSIFICATIONREFERENCE($,'Ss_20_40_07','Bridge suspension cable systems',#2878,$,$); -#2880=IFCCLASSIFICATIONREFERENCE($,'Ss_20_40_07_11','Cable stayed bridge cable systems',#2879,$,$); -#2881=IFCCLASSIFICATIONREFERENCE($,'Ss_20_40_07_85','Suspension bridge cable systems',#2879,$,$); -#2882=IFCCLASSIFICATIONREFERENCE($,'Ss_20_40_10','Building cable systems',#2878,$,$); -#2883=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50','Bridge abutment and pier systems',#2801,$,$); -#2884=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_10','Abutment systems',#2883,$,$); -#2885=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_10_10','Bank seat abutments',#2884,$,$); -#2886=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_10_30','Embedded retaining wall bridge abutments',#2884,$,$); -#2887=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_10_40','Integral abutments',#2884,$,$); -#2888=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_10_50','Masonry bridge abutments',#2884,$,$); -#2889=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_10_70','Reinforced concrete bridge abutments',#2884,$,$); -#2890=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_10_80','Sheet piled bridge abutments',#2884,$,$); -#2891=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_10_85','Spill-through abutments',#2884,$,$); -#2892=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_10_90','Tied embedded retaining wall bridge abutments',#2884,$,$); -#2893=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_10_95','Wing wall systems',#2884,$,$); -#2894=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_20','Bridge pier systems',#2883,$,$); -#2895=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_20_50','Masonry bridge piers',#2894,$,$); -#2896=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_20_70','Reinforced concrete bridge piers',#2894,$,$); -#2897=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_30','Abutment and pier component systems',#2883,$,$); -#2898=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_30_11','Capping beam systems',#2897,$,$); -#2899=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_30_37','Headwall systems',#2897,$,$); -#2900=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_30_80','Spandrel wall systems',#2897,$,$); -#2901=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60','Retaining wall systems',#2801,$,$); -#2902=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_30','Embedded retaining wall systems',#2901,$,$); -#2903=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_30_03','Anchored steel sheet pile embedded retaining wall systems',#2902,$,$); -#2904=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_30_08','Bored king post embedded retaining wall systems',#2902,$,$); -#2905=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_30_13','Combi retaining wall systems',#2902,$,$); -#2906=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_30_15','Contiguous bored pile embedded retaining wall systems',#2902,$,$); -#2907=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_30_24','Driven king post embedded retaining wall systems',#2902,$,$); -#2908=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_30_70','Reinforced concrete diaphragm retaining wall systems',#2902,$,$); -#2909=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_30_80','Secant pile embedded retaining wall systems',#2902,$,$); -#2910=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_30_83','Slurry diaphragm embedded retaining wall systems',#2902,$,$); -#2911=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_30_85','Steel sheet pile embedded retaining wall systems',#2902,$,$); -#2912=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_30_92','Unreinforced concrete diaphragm retaining wall systems',#2902,$,$); -#2913=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_35','Gravity retaining wall systems',#2901,$,$); -#2914=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_35_10','Caged rock unit (gabion) retaining wall systems',#2913,$,$); -#2915=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_35_13','Concrete bagwork retaining wall systems',#2913,$,$); -#2916=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_35_15','Crib retaining wall systems',#2913,$,$); -#2917=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_35_25','Drystack masonry unit retaining wall systems',#2913,$,$); -#2918=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_35_50','Masonry retaining wall systems',#2913,$,$); -#2919=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_35_66','Precast concrete stem wall retaining wall systems',#2913,$,$); -#2920=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_35_70','Reinforced concrete retaining wall systems',#2913,$,$); -#2921=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_35_72','Reinforced earth retaining wall systems',#2913,$,$); -#2922=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_35_90','Timber retaining wall systems',#2913,$,$); -#2923=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_35_91','Tyre bale retaining wall systems',#2913,$,$); -#2924=IFCCLASSIFICATIONREFERENCE($,'Ss_20_70','Structure covering and finishing systems',#2801,$,$); -#2925=IFCCLASSIFICATIONREFERENCE($,'Ss_20_70_15','Concrete protection systems',#2924,$,$); -#2926=IFCCLASSIFICATIONREFERENCE($,'Ss_20_70_65','Protective painting systems',#2924,$,$); -#2927=IFCCLASSIFICATIONREFERENCE($,'Ss_20_70_80','Steel encasement systems',#2924,$,$); -#2928=IFCCLASSIFICATIONREFERENCE($,'Ss_20_80','Structure accessory systems',#2801,$,$); -#2929=IFCCLASSIFICATIONREFERENCE($,'Ss_20_80_60','Permanent formwork systems',#2928,$,$); -#2930=IFCCLASSIFICATIONREFERENCE($,'Ss_20_95','Temporary structural systems',#2801,$,$); -#2931=IFCCLASSIFICATIONREFERENCE($,'Ss_25','Wall and barrier systems',#2695,$,$); -#2932=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10','Framed wall systems',#2931,$,$); -#2933=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_20','Curtain walling systems',#2932,$,$); -#2934=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_20_85','Stick curtain walling systems',#2933,$,$); -#2935=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_20_90','Unitized curtain walling systems',#2933,$,$); -#2936=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_30','Framed partition systems',#2932,$,$); -#2937=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_30_35','Gypsum board partition systems',#2936,$,$); -#2938=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_30_70','Rigid sheet partition systems',#2936,$,$); -#2939=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_32','Framed wall structure systems',#2932,$,$); -#2940=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_32_03','Aluminium wall framing systems',#2939,$,$); -#2941=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_32_35','Heavy steel wall framing systems',#2939,$,$); -#2942=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_32_45','Light steel wall framing systems',#2939,$,$); -#2943=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_32_58','Plastics wall framing systems',#2939,$,$); -#2944=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_32_90','Timber wall framing systems',#2939,$,$); -#2945=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_35','Framed glazed systems',#2932,$,$); -#2946=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_35_35','Glazed screen systems',#2945,$,$); -#2947=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_35_95','Vertical patent glazing systems',#2945,$,$); -#2948=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_35_97','Window wall glazed screen systems',#2945,$,$); -#2949=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11','Monolithic wall structure systems',#2931,$,$); -#2950=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11_13','Cob wall systems',#2949,$,$); -#2951=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11_15','Concrete form masonry unit wall systems',#2949,$,$); -#2952=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11_16','Concrete wall systems',#2949,$,$); -#2953=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11_16_65','Precast concrete wall systems',#2952,$,$); -#2954=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11_16_70','Reinforced concrete wall structure systems',#2952,$,$); -#2955=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11_16_80','Sprayed concrete wall structure systems',#2952,$,$); -#2956=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11_70','Rammed earth wall systems',#2949,$,$); -#2957=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11_70_55','Non-stabilized rammed earth wall systems',#2956,$,$); -#2958=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11_70_83','Stabilized rammed earth plinth systems',#2956,$,$); -#2959=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11_70_85','Stabilized rammed earth wall systems',#2956,$,$); -#2960=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11_90','Timber wall systems',#2949,$,$); -#2961=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11_90_15','Cross-laminated timber wall systems',#2960,$,$); -#2962=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11_90_96','Wood log wall systems',#2960,$,$); -#2963=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12','Panel wall structure systems',#2931,$,$); -#2964=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_10','Brick panel wall systems',#2963,$,$); -#2965=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_15','Concrete panel wall systems',#2963,$,$); -#2966=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_60','Panel enclosure systems',#2963,$,$); -#2967=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_60_30','Fully-framed panel cubicle systems',#2966,$,$); -#2968=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_60_60','Panel cubicle systems',#2966,$,$); -#2969=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_60_65','Privacy screen systems',#2966,$,$); -#2970=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_65','Panel partition systems',#2963,$,$); -#2971=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_65_50','Media wall systems',#2970,$,$); -#2972=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_65_55','Mesh panel partition systems',#2970,$,$); -#2973=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_65_60','Plasterboard laminated partition systems',#2970,$,$); -#2974=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_65_65','Plasterboard panel partition systems',#2970,$,$); -#2975=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_65_70','Relocatable partition and ceiling systems',#2970,$,$); -#2976=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_65_75','Relocatable partition systems',#2970,$,$); -#2977=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_65_85','Storage wall systems',#2970,$,$); -#2978=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_80','Structural glass wall systems',#2963,$,$); -#2979=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_80_65','Point-fixed structural glass wall systems',#2978,$,$); -#2980=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_80_83','Stacked structural glass wall systems',#2978,$,$); -#2981=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_80_85','Suspended structural glass wall systems',#2978,$,$); -#2982=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_85','Structural steel panel wall systems',#2963,$,$); -#2983=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_85_60','Prefabricated metal wall systems',#2982,$,$); -#2984=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_85_63','Profile metal sheet wall systems',#2982,$,$); -#2985=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13','Unit wall structure systems',#2931,$,$); -#2986=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_05','Adobe block wall systems',#2985,$,$); -#2987=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_24','Dry stone wall systems',#2985,$,$); -#2988=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_30','Gabion wall systems',#2985,$,$); -#2989=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_33','Glass wall systems',#2985,$,$); -#2990=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_33_33','Glass block wall systems',#2989,$,$); -#2991=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_33_64','Prefabricated glass block wall systems',#2989,$,$); -#2992=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_35','Gypsum block wall systems',#2985,$,$); -#2993=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_45','Lead brick wall systems',#2985,$,$); -#2994=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_50','Masonry wall systems',#2985,$,$); -#2995=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_50_49','Masonry exposed feature systems',#2994,$,$); -#2996=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_50_51','Masonry wall leaf systems',#2994,$,$); -#2997=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_50_54','Masonry free-standing wall leaf systems',#2994,$,$); -#2998=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_50_56','Masonry internal partition systems',#2994,$,$); -#2999=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_70','Reinforced masonry wall systems',#2985,$,$); -#3000=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_70_71','Reinforced masonry wall leaf systems',#2999,$,$); -#3001=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_70_74','Reinforced masonry free-standing wall leaf systems',#2999,$,$); -#3002=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_70_76','Reinforced masonry internal partition systems',#2999,$,$); -#3003=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_85','Straw bale wall systems',#2985,$,$); -#3004=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_85_30','Framed straw bale wall systems',#3003,$,$); -#3005=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_85_95','Unframed straw bale wall systems',#3003,$,$); -#3006=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14','Fence systems',#2931,$,$); -#3007=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_30','Framed fence systems',#3006,$,$); -#3008=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_55','Monolithic fence systems',#3006,$,$); -#3009=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63','Post, rail and board fence systems',#3006,$,$); -#3010=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_06','Bespoke fencing systems',#3009,$,$); -#3011=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_08','Board or palisade fencing systems',#3009,$,$); -#3012=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_11','Carbon steel continuous bar fencing systems',#3009,$,$); -#3013=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_51','Metal post and rail fencing systems',#3009,$,$); -#3014=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_52','Metal vertical pale fencing systems',#3009,$,$); -#3015=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_56','Natural hurdle fencing systems',#3009,$,$); -#3016=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_62','Post and panel fencing systems',#3009,$,$); -#3017=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_63','Post and rail fencing systems',#3009,$,$); -#3018=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_64','Precast concrete palisade fencing systems',#3009,$,$); -#3019=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_65','Precast concrete post and panel fencing systems',#3009,$,$); -#3020=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_66','Precast concrete post and rail fencing systems',#3009,$,$); -#3021=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_67','Prefabricated wood or plastics panel fencing systems',#3009,$,$); -#3022=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_84','Steel hurdle fencing systems',#3009,$,$); -#3023=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_85','Steel palisade panel fencing systems',#3009,$,$); -#3024=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_86','Steel vertical bar fencing systems',#3009,$,$); -#3025=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_95','Wood close boarded fencing systems',#3009,$,$); -#3026=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_96','Wood palisade fencing systems',#3009,$,$); -#3027=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_97','Wood post and rail fencing systems',#3009,$,$); -#3028=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_98','Wrought iron panel fencing systems',#3009,$,$); -#3029=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_67','Post, wire and mesh fence systems',#3006,$,$); -#3030=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_67_12','Chain link fencing systems',#3029,$,$); -#3031=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_67_14','Cleft chestnut pale fencing systems',#3029,$,$); -#3032=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_67_15','Continuous mesh fencing systems',#3029,$,$); -#3033=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_67_24','Dropper pattern strained wire fencing systems',#3029,$,$); -#3034=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_67_27','Electric fencing systems',#3029,$,$); -#3035=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_67_28','Electric security fencing systems',#3029,$,$); -#3036=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_67_33','General pattern strained wire fencing systems',#3029,$,$); -#3037=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_67_34','General pattern wire mesh fencing systems',#3029,$,$); -#3038=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_67_51','Metal mesh panel fencing systems',#3029,$,$); -#3039=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_67_70','Rope or chain fencing systems',#3029,$,$); -#3040=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_67_80','Spring steel and high tensile wire mesh fencing systems',#3029,$,$); -#3041=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_67_97','Wire fencing systems',#3029,$,$); -#3042=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15','Fixed pedestrian barrier systems',#2931,$,$); -#3043=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60','Pedestrian safety barrier and guarding systems',#3042,$,$); -#3044=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_05','Balustrade and guarding systems',#3043,$,$); -#3045=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_14','Composite barrier systems',#3043,$,$); -#3046=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_15','Composite pedestrian parapet systems',#3043,$,$); -#3047=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_16','Composite post and panel barrier systems',#3043,$,$); -#3048=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_17','Composite post and rail barrier systems',#3043,$,$); -#3049=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_18','Concrete post and rail barrier systems',#3043,$,$); -#3050=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_35','Handrail systems',#3043,$,$); -#3051=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_37','Hoop barrier systems',#3043,$,$); -#3052=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_52','Metal modular barrier systems',#3043,$,$); -#3053=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_53','Metal pedestrian parapet systems',#3043,$,$); -#3054=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_54','Metal post and mesh panel barrier systems',#3043,$,$); -#3055=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_55','Metal post and panel barrier systems',#3043,$,$); -#3056=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_56','Metal post and rail barrier systems',#3043,$,$); -#3057=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_57','Metal vertical bar pedestrian guard rail systems',#3043,$,$); -#3058=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_60','Pedestrian parapet systems',#3043,$,$); -#3059=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_65','Post and panel barrier systems',#3043,$,$); -#3060=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_66','Post and rail barrier systems',#3043,$,$); -#3061=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_67','Post and rope barrier systems',#3043,$,$); -#3062=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_68','Post and wire barrier systems',#3043,$,$); -#3063=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_96','Wood post and panel barrier systems',#3043,$,$); -#3064=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_97','Wood post and rail barrier systems',#3043,$,$); -#3065=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_85','Sports barrier systems',#3042,$,$); -#3066=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_85_55','Multi-use games fencing systems',#3065,$,$); -#3067=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16','Fixed traffic and protective barrier systems',#2931,$,$); -#3068=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_04','Artificial reef systems',#3067,$,$); -#3069=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_05','Avalanche and snow barrier systems',#3067,$,$); -#3070=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_08','Blast barrier systems',#3067,$,$); -#3071=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_08_44','Jet blast deflection systems',#3070,$,$); -#3072=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_21','Debris flow barrier systems',#3067,$,$); -#3073=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_30','Fish barrier systems',#3067,$,$); -#3074=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_46','Landslide barrier systems',#3067,$,$); -#3075=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_50','Coastal, river and waterways protection systems',#3067,$,$); -#3076=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_50_72','Rock armour systems',#3075,$,$); -#3077=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_50_77','Scouring protection systems',#3075,$,$); -#3078=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_50_80','Sea wall systems',#3075,$,$); -#3079=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_73','Road and rail barrier systems',#3067,$,$); -#3080=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_73_03','Acoustic barrier systems',#3079,$,$); -#3081=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_73_05','Anti-throw barrier systems',#3079,$,$); -#3082=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_73_26','Environment protection screen systems',#3079,$,$); -#3083=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_73_80','Socket for temporary barrier systems',#3079,$,$); -#3084=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_76','Rockfall barrier systems',#3067,$,$); -#3085=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_94','Vehicle restraint systems',#3067,$,$); -#3086=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_94_10','Bollard systems',#3085,$,$); -#3087=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_94_14','Combined metal and concrete vehicle safety parapet systems',#3085,$,$); -#3088=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_94_16','Concrete safety barrier (CSB) systems',#3085,$,$); -#3089=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_94_44','Low-speed precast concrete safety parapet (PCONC) systems',#3085,$,$); -#3090=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_94_46','Low-speed masonry safety parapet (PMAS) systems',#3085,$,$); -#3091=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_94_48','Low-speed metal vehicle safety parapet systems',#3085,$,$); -#3092=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_94_50','Metal vehicle safety fence systems',#3085,$,$); -#3093=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_94_65','Protective rail systems',#3085,$,$); -#3094=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_94_95','Vehicle safety control systems',#3085,$,$); -#3095=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_94_97','Wire rope safety fence (WRSF) systems',#3085,$,$); -#3096=IFCCLASSIFICATIONREFERENCE($,'Ss_25_17','Dam and levee structure systems',#2931,$,$); -#3097=IFCCLASSIFICATIONREFERENCE($,'Ss_25_17_05','Arch dam systems',#3096,$,$); -#3098=IFCCLASSIFICATIONREFERENCE($,'Ss_25_17_10','Buttress dam systems',#3096,$,$); -#3099=IFCCLASSIFICATIONREFERENCE($,'Ss_25_17_25','Embankment dam and levee systems',#3096,$,$); -#3100=IFCCLASSIFICATIONREFERENCE($,'Ss_25_17_35','Gravity dam systems',#3096,$,$); -#3101=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20','Wall cladding systems',#2931,$,$); -#3102=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_08','Board cladding systems',#3101,$,$); -#3103=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_08_95','Weatherboarding systems',#3102,$,$); -#3104=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_14','Composite panel cladding systems',#3101,$,$); -#3105=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_14_10','Built up metal insulating sandwich panel cladding systems',#3104,$,$); -#3106=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_14_52','Metal composite panel cladding systems',#3104,$,$); -#3107=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_14_54','Metal insulating sandwich panel cladding systems',#3104,$,$); -#3108=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_14_55','Metal semi-composite panel cladding systems',#3104,$,$); -#3109=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_15','Concrete cladding systems',#3101,$,$); -#3110=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_15_16','Concrete panel cladding systems',#3109,$,$); -#3111=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_33','Glass fibre reinforced concrete (GRC) cladding systems',#3101,$,$); -#3112=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_33_35','GRC cladding systems',#3111,$,$); -#3113=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_34','Glass fibre reinforced gypsum (GRG) cladding systems',#3101,$,$); -#3114=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_34_35','GRG cladding systems',#3113,$,$); -#3115=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_35','Glass fibre reinforced plastics (GRP) cladding systems',#3101,$,$); -#3116=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_35_35','GRP cladding systems',#3115,$,$); -#3117=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_50','Metal sheet fully supported wall covering systems',#3101,$,$); -#3118=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_50_05','Aluminium sheet cladding systems',#3117,$,$); -#3119=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_50_11','Carbon steel sheet cladding systems',#3117,$,$); -#3120=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_50_15','Copper sheet cladding systems',#3117,$,$); -#3121=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_50_45','Lead sheet cladding systems',#3117,$,$); -#3122=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_50_50','Lead-wrapped panel cladding systems',#3117,$,$); -#3123=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_50_85','Stainless steel sheet cladding systems',#3117,$,$); -#3124=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_50_95','Zinc sheet cladding systems',#3117,$,$); -#3125=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_60','Panel and sheet cladding systems',#3101,$,$); -#3126=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_68','Profiled sheet cladding systems',#3101,$,$); -#3127=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_68_30','Fibre cement profiled sheet cladding systems',#3126,$,$); -#3128=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_68_50','Metal profiled sheet cladding systems',#3126,$,$); -#3129=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_68_65','Plastics profiled sheet cladding systems',#3126,$,$); -#3130=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_70','Rainscreen cladding systems',#3101,$,$); -#3131=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_70_25','Drained and back-ventilated rainscreen cladding systems',#3130,$,$); -#3132=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_70_65','Pressure equalized rainscreen cladding systems',#3130,$,$); -#3133=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_72','Sheet cladding systems',#3101,$,$); -#3134=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_72_72','Rigid sheet cladding systems',#3133,$,$); -#3135=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_85','Stone cladding systems',#3101,$,$); -#3136=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_85_50','Manufactured stone cladding systems',#3135,$,$); -#3137=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_85_55','Natural stone cladding systems',#3135,$,$); -#3138=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_90','Unit cladding systems',#3101,$,$); -#3139=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_90_13','Clay plain tile cladding systems',#3138,$,$); -#3140=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_90_15','Concrete plain tile cladding systems',#3138,$,$); -#3141=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_90_30','Fibre cement slate cladding systems',#3138,$,$); -#3142=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_90_50','Metal tile cladding systems',#3138,$,$); -#3143=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_90_55','Natural slate cladding systems',#3138,$,$); -#3144=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_90_65','Precast concrete cladding systems',#3138,$,$); -#3145=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_90_95','Wood shingle or shake cladding systems',#3138,$,$); -#3146=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25','Wall lining systems',#2931,$,$); -#3147=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_05','Acoustic panel systems',#3146,$,$); -#3148=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_45','Lining and casing systems',#3146,$,$); -#3149=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_45_25','Duct and wall panel lining systems',#3148,$,$); -#3150=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_45_33','Gypsum board casing systems',#3148,$,$); -#3151=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_45_35','Gypsum board wall lining systems',#3148,$,$); -#3152=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_45_50','Metal framed wall lining systems',#3148,$,$); -#3153=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_45_68','Rigid sheet casing systems',#3148,$,$); -#3154=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_45_70','Rigid sheet wall lining systems',#3148,$,$); -#3155=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_45_88','Timber board casing systems',#3148,$,$); -#3156=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_45_90','Timber board wall lining systems',#3148,$,$); -#3157=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_70','Radiation shielding lining systems',#3146,$,$); -#3158=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_75','Rigid sheet fine lining and panelling systems',#3146,$,$); -#3159=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_75_05','Acoustic panel lining systems',#3158,$,$); -#3160=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_75_30','Framed wood panel lining systems',#3158,$,$); -#3161=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_75_63','Plastics panel lining systems',#3158,$,$); -#3162=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_75_65','Plastics veneered panel lining systems',#3158,$,$); -#3163=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_75_85','Specialist faced panel lining systems',#3158,$,$); -#3164=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_75_95','Wood veneered panel lining systems',#3158,$,$); -#3165=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_85','Stone lining systems',#3146,$,$); -#3166=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_85_50','Manufactured stone lining systems',#3165,$,$); -#3167=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_85_55','Natural stone lining systems',#3165,$,$); -#3168=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_95','Wall sheathing systems',#3146,$,$); -#3169=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_95_28','External wall sheathing systems',#3168,$,$); -#3170=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30','Door and window systems',#2931,$,$); -#3171=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_15','Concrete wall glazing systems',#3170,$,$); -#3172=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_15_66','Precast concrete security window systems',#3171,$,$); -#3173=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20','Door, shutter and hatch systems',#3170,$,$); -#3174=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_16','Collapsible gate and grille doorset systems',#3173,$,$); -#3175=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_22','Door assembly systems',#3173,$,$); -#3176=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_25','Doorset systems',#3173,$,$); -#3177=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_30','Frame and door leaf systems',#3173,$,$); -#3178=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_32','Frameless glass door systems',#3173,$,$); -#3179=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_35','Hatch systems',#3173,$,$); -#3180=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_37','High security doorset systems',#3173,$,$); -#3181=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_38','High speed doorset systems',#3173,$,$); -#3182=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_39','Hinged doorset systems',#3173,$,$); -#3183=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_40','Industrial doorset systems',#3173,$,$); -#3184=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_45','Loading bay doorset systems',#3173,$,$); -#3185=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_46','Louvre doorset systems',#3173,$,$); -#3186=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_62','Pivot doorset systems',#3173,$,$); -#3187=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_65','Platform door systems',#3173,$,$); -#3188=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_70','Revolving doorset systems',#3173,$,$); -#3189=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_73','Roller grille doorset systems',#3173,$,$); -#3190=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_74','Roller shutter doorset systems',#3173,$,$); -#3191=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_76','Sectional overhead doorset systems',#3173,$,$); -#3192=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_77','Sliding doorset systems',#3173,$,$); -#3193=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_78','Sliding folding doorset systems',#3173,$,$); -#3194=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_80','Sliding stacking panel partition systems',#3173,$,$); -#3195=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_84','Strip curtain doorset systems',#3173,$,$); -#3196=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_93','Up and over doorset systems',#3173,$,$); -#3197=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_29','Fire and smoke curtain systems',#3170,$,$); -#3198=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_29_30','Fire curtain systems',#3197,$,$); -#3199=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_29_80','Smoke curtain systems',#3197,$,$); -#3200=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_95','Window systems',#3170,$,$); -#3201=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_95_26','External window systems',#3200,$,$); -#3202=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_95_41','Internal window systems',#3200,$,$); -#3203=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_95_96','Window walling systems',#3200,$,$); -#3204=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32','Gate and access control systems',#2931,$,$); -#3205=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_35','Gate systems',#3204,$,$); -#3206=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_35_05','Animal gate systems',#3205,$,$); -#3207=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_35_15','Chicane systems',#3205,$,$); -#3208=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_35_30','Folding gate systems',#3205,$,$); -#3209=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_35_37','Hinged gate systems',#3205,$,$); -#3210=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_35_41','In-line inhibitor systems',#3205,$,$); -#3211=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_35_45','Kissing gate systems',#3205,$,$); -#3212=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_35_80','Sliding gate systems',#3205,$,$); -#3213=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_35_85','Stile systems',#3205,$,$); -#3214=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_35_90','Turnstile systems',#3205,$,$); -#3215=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_60','Passport control gate systems',#3204,$,$); -#3216=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_60_26','e-passport gate systems',#3215,$,$); -#3217=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_60_60','Passport gate systems',#3215,$,$); -#3218=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_70','Railway platform automated barrier systems',#3204,$,$); -#3219=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36','Operable barrier systems',#2931,$,$); -#3220=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_24','Dry dock automated gate systems',#3219,$,$); -#3221=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_30','Flood and storm surge barrier systems',#3219,$,$); -#3222=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_30_30','Flood gate systems',#3221,$,$); -#3223=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_50','Marina and sea gate automated systems',#3219,$,$); -#3224=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_58','Operable rail barrier systems',#3219,$,$); -#3225=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_62','Operable water barrier systems',#3219,$,$); -#3226=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_64','Operable bridge barrier systems',#3219,$,$); -#3227=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_66','Operable tunnel barrier systems',#3219,$,$); -#3228=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_70','Railway crossing systems',#3219,$,$); -#3229=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_95','Vehicle access point control systems',#3219,$,$); -#3230=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_95_05','Automated heavy-duty gate systems',#3229,$,$); -#3231=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_95_35','Heavy duty sliding beam barrier systems',#3229,$,$); -#3232=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_95_36','Height restrictor systems',#3229,$,$); -#3233=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_95_38','Horizontal swing gate systems',#3229,$,$); -#3234=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_95_40','Hydraulic ramp systems',#3229,$,$); -#3235=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_95_50','Movable bollard and car park post systems',#3229,$,$); -#3236=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_95_70','Rising arm barrier systems',#3229,$,$); -#3237=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_95_72','Rising bollard systems',#3229,$,$); -#3238=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_95_85','Static bollard systems',#3229,$,$); -#3239=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_95_94','Vehicle flow plate systems',#3229,$,$); -#3240=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_95_96','Vehicle stop systems',#3229,$,$); -#3241=IFCCLASSIFICATIONREFERENCE($,'Ss_25_38','Wall and barrier opening hardware systems',#2931,$,$); -#3242=IFCCLASSIFICATIONREFERENCE($,'Ss_25_38_20','Door, window and gate hardware systems',#3241,$,$); -#3243=IFCCLASSIFICATIONREFERENCE($,'Ss_25_38_20_20','Door hardware systems',#3242,$,$); -#3244=IFCCLASSIFICATIONREFERENCE($,'Ss_25_38_20_30','Garage door hardware systems',#3242,$,$); -#3245=IFCCLASSIFICATIONREFERENCE($,'Ss_25_38_20_33','Gate hardware systems',#3242,$,$); -#3246=IFCCLASSIFICATIONREFERENCE($,'Ss_25_38_20_35','Hatch hardware systems',#3242,$,$); -#3247=IFCCLASSIFICATIONREFERENCE($,'Ss_25_38_20_70','Relocatable partition hardware systems',#3242,$,$); -#3248=IFCCLASSIFICATIONREFERENCE($,'Ss_25_38_20_80','Shutter hardware systems',#3242,$,$); -#3249=IFCCLASSIFICATIONREFERENCE($,'Ss_25_38_20_95','Window hardware systems',#3242,$,$); -#3250=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45','Wall covering and finish systems',#2931,$,$); -#3251=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_02','Acoustic covering systems',#3250,$,$); -#3252=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_02_60','Parge coat systems',#3251,$,$); -#3253=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_25','Drapery systems',#3250,$,$); -#3254=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_70','Render and roughcast coating systems',#3250,$,$); -#3255=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_70_55','Multicoat render systems',#3254,$,$); -#3256=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_70_60','One coat render systems',#3254,$,$); -#3257=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_70_90','Tiling and mosaic render substrate systems',#3254,$,$); -#3258=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_72','Rendered insulation systems',#3250,$,$); -#3259=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_72_02','Adhesive fixed external wall insulation systems',#3258,$,$); -#3260=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_72_42','Insulated plinth systems',#3258,$,$); -#3261=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_72_70','Rail fixed external wall insulation systems',#3258,$,$); -#3262=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_74','Rolled paper and fabric covering systems',#3250,$,$); -#3263=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_74_70','Rolled covering systems',#3262,$,$); -#3264=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_85','Sprayed coating systems',#3250,$,$); -#3265=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_85_82','Sprayed external monolithic coating systems',#3264,$,$); -#3266=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_85_85','Sprayed internal monolithic coating systems',#3264,$,$); -#3267=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_86','Suspended render systems',#3250,$,$); -#3268=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_88','Tiling systems',#3250,$,$); -#3269=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_88_25','External wall tiling systems',#3268,$,$); -#3270=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_88_40','Internal wall tiling systems',#3268,$,$); -#3271=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_88_88','Terrazzo wall tiling systems',#3268,$,$); -#3272=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_88_90','Tiling and mosaic mortar substrate systems',#3268,$,$); -#3273=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_90','Unit facing systems',#3250,$,$); -#3274=IFCCLASSIFICATIONREFERENCE($,'Ss_25_50','Wall mounted canopy and screen systems',#2931,$,$); -#3275=IFCCLASSIFICATIONREFERENCE($,'Ss_25_50_05','Awning systems',#3274,$,$); -#3276=IFCCLASSIFICATIONREFERENCE($,'Ss_25_50_35','Grille systems',#3274,$,$); -#3277=IFCCLASSIFICATIONREFERENCE($,'Ss_25_50_45','Louvre and shading systems',#3274,$,$); -#3278=IFCCLASSIFICATIONREFERENCE($,'Ss_25_50_45_10','Canopy systems',#3277,$,$); -#3279=IFCCLASSIFICATIONREFERENCE($,'Ss_25_50_45_30','Facade-aligned brise soleil systems',#3277,$,$); -#3280=IFCCLASSIFICATIONREFERENCE($,'Ss_25_50_45_45','Louvre screen systems',#3277,$,$); -#3281=IFCCLASSIFICATIONREFERENCE($,'Ss_25_50_45_60','Panellized louvre screen systems',#3277,$,$); -#3282=IFCCLASSIFICATIONREFERENCE($,'Ss_25_50_45_65','Projecting brise soleil systems',#3277,$,$); -#3283=IFCCLASSIFICATIONREFERENCE($,'Ss_25_50_75','Screen systems',#3274,$,$); -#3284=IFCCLASSIFICATIONREFERENCE($,'Ss_25_50_80','Shutter systems',#3274,$,$); -#3285=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60','Wall and barrier accessory systems',#2931,$,$); -#3286=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_10','Cavity wall tie renewal and insertion systems',#3285,$,$); -#3287=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_30','Fire stopping systems',#3285,$,$); -#3288=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_30_40','Individual services penetrations fire stopping systems',#3287,$,$); -#3289=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_30_45','Linear gap fire stopping systems',#3287,$,$); -#3290=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_30_48','Loose fire stopping systems',#3287,$,$); -#3291=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_30_55','Multiple services penetrations fire stopping systems',#3287,$,$); -#3292=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_30_62','Pipe collar fire stopping systems',#3287,$,$); -#3293=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_35','Glazing systems',#3285,$,$); -#3294=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_35_06','Bead-fixed insulating glazing systems',#3293,$,$); -#3295=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_35_08','Bead-fixed single glazing systems',#3293,$,$); -#3296=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_35_30','Fire-resistant glazing systems',#3293,$,$); -#3297=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_35_33','Glazing film systems',#3293,$,$); -#3298=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_35_35','Groove-fixed single glazing systems',#3293,$,$); -#3299=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_35_40','Internal use bead and tape, groove or channel glazing systems',#3293,$,$); -#3300=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_35_50','Mirror glazing systems',#3293,$,$); -#3301=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_35_65','Putty-fronted single glazing systems',#3293,$,$); -#3302=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_35_75','Single-sided gasket glazing systems',#3293,$,$); -#3303=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_35_85','Structural zipper gasket glazing systems',#3293,$,$); -#3304=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_35_95','U-profiled glazing systems',#3293,$,$); -#3305=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50','Metal sheet wall flashing and weathering systems',#3285,$,$); -#3306=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50_03','Aluminium sheet wall flashing systems',#3305,$,$); -#3307=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50_04','Aluminium sheet wall weathering systems',#3305,$,$); -#3308=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50_11','Carbon steel wall flashing systems',#3305,$,$); -#3309=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50_12','Carbon steel wall weathering systems',#3305,$,$); -#3310=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50_14','Copper sheet wall flashing systems',#3305,$,$); -#3311=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50_15','Copper sheet wall weathering systems',#3305,$,$); -#3312=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50_47','Lead damp proof course systems',#3305,$,$); -#3313=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50_48','Lead sheet wall flashing systems',#3305,$,$); -#3314=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50_49','Lead sheet wall weathering systems',#3305,$,$); -#3315=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50_84','Stainless steel sheet wall flashing systems',#3305,$,$); -#3316=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50_85','Stainless steel sheet wall weathering systems',#3305,$,$); -#3317=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50_94','Zinc sheet wall flashing systems',#3305,$,$); -#3318=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50_95','Zinc sheet wall weathering systems',#3305,$,$); -#3319=IFCCLASSIFICATIONREFERENCE($,'Ss_25_95','Temporary wall and barrier systems',#2931,$,$); -#3320=IFCCLASSIFICATIONREFERENCE($,'Ss_25_95_30','Temporary flood barrier systems',#3319,$,$); -#3321=IFCCLASSIFICATIONREFERENCE($,'Ss_25_95_60','Temporary pedestrian barrier systems',#3319,$,$); -#3322=IFCCLASSIFICATIONREFERENCE($,'Ss_25_95_70','Temporary rail barrier systems',#3319,$,$); -#3323=IFCCLASSIFICATIONREFERENCE($,'Ss_25_95_75','Temporary road barrier systems',#3319,$,$); -#3324=IFCCLASSIFICATIONREFERENCE($,'Ss_25_95_85','Temporary traffic barrier systems',#3319,$,$); -#3325=IFCCLASSIFICATIONREFERENCE($,'Ss_25_95_90','Temporary water barrier systems',#3319,$,$); -#3326=IFCCLASSIFICATIONREFERENCE($,'Ss_30','Roof, floor and paving systems',#2695,$,$); -#3327=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10','Pitched, arched and domed roof structure systems',#3326,$,$); -#3328=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_30','Framed roof structure systems',#3327,$,$); -#3329=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_30_03','Aluminium roof framing systems',#3328,$,$); -#3330=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_30_20','Glazed unit roof framing systems',#3328,$,$); -#3331=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_30_25','Heavy steel roof framing systems',#3328,$,$); -#3332=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_30_30','Heavy steel roof space frame systems',#3328,$,$); -#3333=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_30_35','Heavy steel roof space truss systems',#3328,$,$); -#3334=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_30_45','Light steel roof framing systems',#3328,$,$); -#3335=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_30_58','Plastics roof framing systems',#3328,$,$); -#3336=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_30_60','Precast concrete roof structure systems',#3328,$,$); -#3337=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_30_70','Reinforced concrete roof framing systems',#3328,$,$); -#3338=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_30_85','Timber roof framing systems',#3328,$,$); -#3339=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_50','Monolithic roof structure systems',#3327,$,$); -#3340=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_50_70','Sprayed concrete roof systems',#3339,$,$); -#3341=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_60','Panel roof structure systems',#3327,$,$); -#3342=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_90','Unit roof structure systems',#3327,$,$); -#3343=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_90_50','Masonry roof systems',#3342,$,$); -#3344=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12','Flat roof, floor and deck structure systems',#3326,$,$); -#3345=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_05','Beam and block floor systems',#3344,$,$); -#3346=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_15','Concrete plank floor systems',#3344,$,$); -#3347=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_20','Deck systems',#3344,$,$); -#3348=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_30','Flat roof and floor cassette structural insulated panel (SIP) systems',#3344,$,$); -#3349=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_32','Framed decking systems',#3344,$,$); -#3350=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_33','Framed floor systems',#3344,$,$); -#3351=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_34','Framed mezzanine systems',#3344,$,$); -#3352=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_35','Glass unit masonry floor systems',#3344,$,$); -#3353=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_45','Lift-up concrete plank floor systems',#3344,$,$); -#3354=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_50','Masonry (flat arch) floor systems',#3344,$,$); -#3355=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_60','Pier and jetty structure systems',#3344,$,$); -#3356=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_64','Platform systems',#3344,$,$); -#3357=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_64_17','Crosswall platform systems',#3356,$,$); -#3358=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_64_30','Front wall platform systems',#3356,$,$); -#3359=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_64_53','Modular platform systems',#3356,$,$); -#3360=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_85','Structural deck systems',#3344,$,$); -#3361=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_85_15','Composite concrete floor, roof or balcony deck systems',#3360,$,$); -#3362=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_85_16','Composite steel and concrete floor, roof or balcony deck systems',#3360,$,$); -#3363=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_85_17','Concrete beam and block floor or roof deck systems',#3360,$,$); -#3364=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_85_18','Concrete floor or roof deck systems',#3360,$,$); -#3365=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_85_30','Glazed unit floor or roof deck systems',#3360,$,$); -#3366=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_85_40','Heavy steel floor, roof or balcony deck systems',#3360,$,$); -#3367=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_85_50','Light steel floor, roof or balcony deck systems',#3360,$,$); -#3368=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_85_65','Post tensioned concrete floor or roof deck systems',#3360,$,$); -#3369=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_85_70','Reinforced concrete floor, roof or balcony deck systems',#3360,$,$); -#3370=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_85_90','Timber floor, roof or balcony deck systems',#3360,$,$); -#3371=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14','Paving systems',#3326,$,$); -#3372=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_02','Acrylic and resin bound aggregate paving systems',#3371,$,$); -#3373=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_02_30','Fibre-reinforced resin-bound aggregate overlay systems',#3372,$,$); -#3374=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_02_41','Impact absorbing synthetic play and sport paving systems',#3372,$,$); -#3375=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_02_42','Impervious acrylic coated sports paving systems',#3372,$,$); -#3376=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_02_70','Resin-bonded aggregate paving systems',#3372,$,$); -#3377=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_02_71','Resin-bound aggregate light duty paving systems',#3372,$,$); -#3378=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_02_72','Resin-bound aggregate heavy duty paving systems',#3372,$,$); -#3379=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_02_73','Resin-bound aggregate overlay systems',#3372,$,$); -#3380=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_02_74','Resin-bound stone aggregate sports paving systems',#3372,$,$); -#3381=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_02_85','Synthetic play surfacing systems',#3372,$,$); -#3382=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_05','Asphalt road and paving systems',#3371,$,$); -#3383=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_05_05','Asphalt concrete light duty paving systems',#3382,$,$); -#3384=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_05_06','Asphalt concrete paving systems',#3382,$,$); -#3385=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_05_07','Asphalt concrete runway paving systems',#3382,$,$); -#3386=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_05_08','Asphalt concrete surface overlay systems',#3382,$,$); -#3387=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_05_35','Hot rolled asphalt paving systems',#3382,$,$); -#3388=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_05_36','Hot rolled asphalt runway paving systems',#3382,$,$); -#3389=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_05_40','Hot rolled asphalt sports paving systems',#3382,$,$); -#3390=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_05_50','Mastic asphalt pedestrian paving systems',#3382,$,$); -#3391=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_05_65','Porous asphalt concrete paving systems',#3382,$,$); -#3392=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_05_70','Porous asphalt concrete sports paving systems',#3382,$,$); -#3393=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_05_75','Stone mastic asphalt paving systems',#3382,$,$); -#3394=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_15','Concrete road and paving systems',#3371,$,$); -#3395=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_15_14','Concrete grass-filled paving systems',#3394,$,$); -#3396=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_15_16','Concrete paving systems',#3394,$,$); -#3397=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_15_17','Concrete porous paving systems',#3394,$,$); -#3398=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_15_18','Concrete runway paving systems',#3394,$,$); -#3399=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_50','Mat and sheet paving systems',#3371,$,$); -#3400=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_50_25','Dry ski slope synthetic matting systems',#3399,$,$); -#3401=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_50_65','Polymeric sports paving systems',#3399,$,$); -#3402=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_50_80','Synthetic grass surfacing systems',#3399,$,$); -#3403=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_80','Unbound aggregate paving systems',#3371,$,$); -#3404=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_80_30','Fast dry clay sports paving systems',#3403,$,$); -#3405=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_80_37','Hoggin paving systems',#3403,$,$); -#3406=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_80_40','Hard binding gravel paving systems',#3403,$,$); -#3407=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_80_45','Loose laid aggregate paving systems',#3403,$,$); -#3408=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_80_47','Loose aggregate overlay systems',#3403,$,$); -#3409=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_80_48','Loose gravel paving systems',#3403,$,$); -#3410=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_80_75','Sand play surfacing systems',#3403,$,$); -#3411=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_80_80','Slurry surfacing overlay systems',#3403,$,$); -#3412=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_80_90','Unbound aggregate cycle paving systems',#3403,$,$); -#3413=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_80_95','Woodchip and stone trim trail paving systems',#3403,$,$); -#3414=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_80_98','Woodchip and woodfibre surface paving systems',#3403,$,$); -#3415=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90','Unit paving systems',#3371,$,$); -#3416=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90_11','Cellular plastics grass-filled paving systems',#3415,$,$); -#3417=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90_12','Cellular plastics gravel-filled paving systems',#3415,$,$); -#3418=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90_30','Flag and slab bound paving systems',#3415,$,$); -#3419=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90_32','Flag and slab paving overlay systems',#3415,$,$); -#3420=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90_34','Flag and slab pedestal-supported paving systems',#3415,$,$); -#3421=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90_36','Flag and slab unbound paving systems',#3415,$,$); -#3422=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90_50','Mosaic paving systems',#3415,$,$); -#3423=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90_60','Permeable flag and slab paving systems',#3415,$,$); -#3424=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90_62','Permeable small unit paving systems',#3415,$,$); -#3425=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90_70','Rail track paving systems',#3415,$,$); -#3426=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90_75','Small unit bound paving systems',#3415,$,$); -#3427=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90_80','Small unit paving overlay systems',#3415,$,$); -#3428=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90_85','Small unit unbound paving systems',#3415,$,$); -#3429=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16','Static bridge deck structure systems',#3326,$,$); -#3430=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_10','Bridge deck systems',#3429,$,$); -#3431=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_10_08','Box girder bridge deck systems',#3430,$,$); -#3432=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_10_12','Composite steel and concrete bridge deck systems',#3430,$,$); -#3433=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_10_13','Conarch bridge systems',#3430,$,$); -#3434=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_10_15','Concrete half through deck systems',#3430,$,$); -#3435=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_10_16','Concrete slab deck systems',#3430,$,$); -#3436=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_10_30','Filler beam deck systems',#3430,$,$); -#3437=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_10_31','Flat and stepped deck systems',#3430,$,$); -#3438=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_10_53','Modular precast concrete deck systems',#3430,$,$); -#3439=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_10_59','Orthotropic deck systems',#3430,$,$); -#3440=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_10_65','Pre-stressed concrete beam deck systems',#3430,$,$); -#3441=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_10_80','Solid steel slab systems',#3430,$,$); -#3442=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_30','Bridge expansion joint systems',#3429,$,$); -#3443=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_30_04','Asphaltic plug joint systems',#3442,$,$); -#3444=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_30_09','Buried expansion joint systems',#3442,$,$); -#3445=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_30_56','Nosing expansion joint systems with poured sealants',#3442,$,$); -#3446=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_30_57','Nosing expansion joint systems with preformed compression seals',#3442,$,$); -#3447=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20','Flooring and decking systems',#3326,$,$); -#3448=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_10','Board and rigid sheet floor systems',#3447,$,$); -#3449=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_10_10','Battened timber board floating floor systems',#3448,$,$); -#3450=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_10_15','Battened wood-based rigid sheet floating floor systems',#3448,$,$); -#3451=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_10_45','Joist-supported timber board floor systems',#3448,$,$); -#3452=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_10_50','Joist-supported wood-based rigid sheet floor systems',#3448,$,$); -#3453=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_10_95','Wood-based rigid sheet floating floor systems',#3448,$,$); -#3454=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_15','Construction site',#3447,$,$); -#3455=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_22','Demountable athletics floor systems',#3447,$,$); -#3456=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_30','External deck and boardwalk systems',#3447,$,$); -#3457=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_30_10','Boardwalk systems',#3456,$,$); -#3458=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_30_25','Decking systems',#3456,$,$); -#3459=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_70','Raised floor systems',#3447,$,$); -#3460=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_70_70','Raised access floor systems',#3459,$,$); -#3461=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_90','Wood and composite unit flooring systems',#3447,$,$); -#3462=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_90_15','Composition block flooring systems',#3461,$,$); -#3463=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_90_50','Mosaic parquet panel flooring systems',#3461,$,$); -#3464=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_90_95','Wood block flooring systems',#3461,$,$); -#3465=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_95','Wood strip and board fine flooring systems',#3447,$,$); -#3466=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_95_10','Battened wood floating floor systems',#3465,$,$); -#3467=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_95_15','Composite laminate floating floor systems',#3465,$,$); -#3468=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_95_20','Direct-fixed wood floor systems',#3465,$,$); -#3469=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_95_25','Direct-glued wood floor systems',#3465,$,$); -#3470=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_95_95','Wood floating floor systems',#3465,$,$); -#3471=IFCCLASSIFICATIONREFERENCE($,'Ss_30_25','Ceiling and soffit systems',#3326,$,$); -#3472=IFCCLASSIFICATIONREFERENCE($,'Ss_30_25_10','Board and sheet ceiling systems',#3471,$,$); -#3473=IFCCLASSIFICATIONREFERENCE($,'Ss_30_25_10_10','Board suspended ceiling systems',#3472,$,$); -#3474=IFCCLASSIFICATIONREFERENCE($,'Ss_30_25_10_26','External ceiling systems',#3472,$,$); -#3475=IFCCLASSIFICATIONREFERENCE($,'Ss_30_25_10_28','External soffit systems',#3472,$,$); -#3476=IFCCLASSIFICATIONREFERENCE($,'Ss_30_25_10_80','Soffit lining and beam casing systems',#3472,$,$); -#3477=IFCCLASSIFICATIONREFERENCE($,'Ss_30_25_22','Demountable suspended ceiling systems',#3471,$,$); -#3478=IFCCLASSIFICATIONREFERENCE($,'Ss_30_25_22_01','Acoustic baffle suspended ceiling systems',#3477,$,$); -#3479=IFCCLASSIFICATIONREFERENCE($,'Ss_30_25_22_30','Fabric membrane ceiling systems',#3477,$,$); -#3480=IFCCLASSIFICATIONREFERENCE($,'Ss_30_25_22_52','Monolithic suspended ceiling systems',#3477,$,$); -#3481=IFCCLASSIFICATIONREFERENCE($,'Ss_30_25_22_70','Raft or island suspended ceiling systems',#3477,$,$); -#3482=IFCCLASSIFICATIONREFERENCE($,'Ss_30_25_22_90','Unit/ modular suspended ceiling systems',#3477,$,$); -#3483=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30','Roof opening systems',#3326,$,$); -#3484=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30_15','Concrete roof glazing systems',#3483,$,$); -#3485=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30_15_42','In situ concrete roof glazing systems',#3484,$,$); -#3486=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30_15_64','Precast concrete lift-out access roof glazing systems',#3484,$,$); -#3487=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30_15_65','Precast concrete roof glazing systems',#3484,$,$); -#3488=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30_34','Glass unit masonry roof light systems',#3483,$,$); -#3489=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30_71','Roof hatch systems',#3483,$,$); -#3490=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30_72','Rooflight and roof window systems',#3483,$,$); -#3491=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30_72_21','Daylight pipe systems',#3490,$,$); -#3492=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30_72_72','Rooflight systems',#3490,$,$); -#3493=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30_72_73','Roof window systems',#3490,$,$); -#3494=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30_73','Roof ventilator systems',#3483,$,$); -#3495=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30_73_60','Passive roof natural ventilator systems',#3494,$,$); -#3496=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30_73_72','Roof smoke ventilator systems',#3494,$,$); -#3497=IFCCLASSIFICATIONREFERENCE($,'Ss_30_32','Floor opening systems',#3326,$,$); -#3498=IFCCLASSIFICATIONREFERENCE($,'Ss_30_32_15','Floor glazing systems',#3497,$,$); -#3499=IFCCLASSIFICATIONREFERENCE($,'Ss_30_32_15_15','Concrete floor glazing systems',#3498,$,$); -#3500=IFCCLASSIFICATIONREFERENCE($,'Ss_30_32_15_64','Precast concrete lift-out access floor glazing systems',#3498,$,$); -#3501=IFCCLASSIFICATIONREFERENCE($,'Ss_30_32_15_65','Precast concrete floor glazing systems',#3498,$,$); -#3502=IFCCLASSIFICATIONREFERENCE($,'Ss_30_32_30','Floor hatch systems',#3497,$,$); -#3503=IFCCLASSIFICATIONREFERENCE($,'Ss_30_34','Pavement opening systems',#3326,$,$); -#3504=IFCCLASSIFICATIONREFERENCE($,'Ss_30_34_03','Animal grid systems',#3503,$,$); -#3505=IFCCLASSIFICATIONREFERENCE($,'Ss_30_34_03_11','Cattle grid systems',#3504,$,$); -#3506=IFCCLASSIFICATIONREFERENCE($,'Ss_30_34_15','Pavement glazing systems',#3503,$,$); -#3507=IFCCLASSIFICATIONREFERENCE($,'Ss_30_34_15_15','Concrete pavement glazing systems',#3506,$,$); -#3508=IFCCLASSIFICATIONREFERENCE($,'Ss_30_34_15_64','Precast concrete lift-out access pavement glazing systems',#3506,$,$); -#3509=IFCCLASSIFICATIONREFERENCE($,'Ss_30_34_15_65','Precast concrete pavement glazing systems',#3506,$,$); -#3510=IFCCLASSIFICATIONREFERENCE($,'Ss_30_34_16','Pavement smoke venting systems',#3503,$,$); -#3511=IFCCLASSIFICATIONREFERENCE($,'Ss_30_34_16_15','Concrete pavement glazing smoke venting systems',#3510,$,$); -#3512=IFCCLASSIFICATIONREFERENCE($,'Ss_30_34_16_16','Concrete pavement non-glazed smoke venting systems',#3510,$,$); -#3513=IFCCLASSIFICATIONREFERENCE($,'Ss_30_34_16_64','Precast concrete pavement glazing smoke venting systems',#3510,$,$); -#3514=IFCCLASSIFICATIONREFERENCE($,'Ss_30_34_16_65','Precast concrete pavement non-glazed smoke venting systems',#3510,$,$); -#3515=IFCCLASSIFICATIONREFERENCE($,'Ss_30_36','Ceiling and soffit opening systems',#3326,$,$); -#3516=IFCCLASSIFICATIONREFERENCE($,'Ss_30_36_10','Ceiling hatch systems',#3515,$,$); -#3517=IFCCLASSIFICATIONREFERENCE($,'Ss_30_36_75','Soffit vent systems',#3515,$,$); -#3518=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40','Roof and balcony covering and finish systems',#3326,$,$); -#3519=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_10','Board roof covering systems',#3518,$,$); -#3520=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_10_30','Flat board roof deck systems',#3519,$,$); -#3521=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_10_60','Pitched board roof sarking systems',#3519,$,$); -#3522=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_30','Flat roof covering systems',#3518,$,$); -#3523=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_30_40','Liquid-applied cold roof covering systems',#3522,$,$); -#3524=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_30_42','Liquid-applied inverted roof covering systems',#3522,$,$); -#3525=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_30_43','Liquid-applied warm roof covering systems',#3522,$,$); -#3526=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_30_50','Mastic asphalt cold roof covering systems',#3522,$,$); -#3527=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_30_52','Mastic asphalt inverted roof covering systems',#3522,$,$); -#3528=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_30_55','Mastic asphalt warm roof covering systems',#3522,$,$); -#3529=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_30_70','Reinforced bitumen membrane cold roof covering systems',#3522,$,$); -#3530=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_30_71','Reinforced bitumen membrane inverted roof covering systems',#3522,$,$); -#3531=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_30_72','Reinforced bitumen membrane warm roof covering systems',#3522,$,$); -#3532=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_30_78','Single layer sheet cold roof covering systems',#3522,$,$); -#3533=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_30_79','Single layer sheet inverted roof covering systems',#3522,$,$); -#3534=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_30_80','Single layer sheet warm roof covering systems',#3522,$,$); -#3535=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_34','Glass roofing systems',#3518,$,$); -#3536=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_34_15','Cantilevered structural glass beam canopy systems',#3535,$,$); -#3537=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_34_60','Point-fixed structural glass canopy systems',#3535,$,$); -#3538=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_34_65','Point-fixed structural glass roof systems',#3535,$,$); -#3539=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_34_70','Point-fixed structural glass soffit systems',#3535,$,$); -#3540=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_34_75','Sloping patent glazing systems',#3535,$,$); -#3541=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50','Metal sheet, fully supported roof and dormer covering systems',#3518,$,$); -#3542=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50_05','Aluminium sheet dormer covering systems',#3541,$,$); -#3543=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50_10','Aluminium sheet roof covering systems',#3541,$,$); -#3544=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50_12','Carbon steel sheet dormer covering systems',#3541,$,$); -#3545=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50_13','Carbon steel sheet roof covering systems',#3541,$,$); -#3546=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50_15','Copper sheet dormer covering systems',#3541,$,$); -#3547=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50_20','Copper sheet roof covering systems',#3541,$,$); -#3548=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50_40','Lead sheet dormer covering systems',#3541,$,$); -#3549=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50_45','Lead sheet roof covering systems',#3541,$,$); -#3550=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50_50','Lead-wrapped panel systems',#3541,$,$); -#3551=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50_75','Stainless steel sheet dormer covering systems',#3541,$,$); -#3552=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50_80','Stainless steel sheet roof covering systems',#3541,$,$); -#3553=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50_90','Zinc sheet dormer covering systems',#3541,$,$); -#3554=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50_95','Zinc sheet roof covering systems',#3541,$,$); -#3555=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_55','Metal composite panel roof covering systems',#3518,$,$); -#3556=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_55_10','Built up metal insulating sandwich panel roof systems',#3555,$,$); -#3557=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_55_50','Metal composite panel roofing systems',#3555,$,$); -#3558=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_55_54','Metal insulating sandwich panel roof systems',#3555,$,$); -#3559=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_55_55','Metal semi-composite panel roofing systems',#3555,$,$); -#3560=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_65','Profiled sheet roof covering systems',#3518,$,$); -#3561=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_65_30','Fibre cement profiled sheet roof covering systems',#3560,$,$); -#3562=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_65_50','Metal profiled sheet roof covering systems',#3560,$,$); -#3563=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_65_60','Plastics profiled sheet roof covering systems',#3560,$,$); -#3564=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_90','Tensile fabric roofing systems',#3518,$,$); -#3565=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_90_40','Internal single layer tensile fabric roofing systems',#3564,$,$); -#3566=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_90_50','Multilayer tensile fabric roofing systems',#3564,$,$); -#3567=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_90_75','Single layer tensile fabric roofing systems',#3564,$,$); -#3568=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_92','Thatch roof covering systems',#3518,$,$); -#3569=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_92_85','Thatch roofing systems',#3568,$,$); -#3570=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_95','Unit roofing systems',#3518,$,$); -#3571=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_95_10','Bitumen membrane shingle roofing systems',#3570,$,$); -#3572=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_95_15','Ceramic slate roofing systems',#3570,$,$); -#3573=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_95_30','Fibre cement slate roofing systems',#3570,$,$); -#3574=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_95_40','Interlocking tile roofing systems',#3570,$,$); -#3575=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_95_50','Metal tile roofing systems',#3570,$,$); -#3576=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_95_55','Natural slate roofing systems',#3570,$,$); -#3577=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_95_60','Natural stone slate roofing systems',#3570,$,$); -#3578=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_95_65','Plain tile roofing systems',#3570,$,$); -#3579=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_95_70','Reconstituted slate roofing systems',#3570,$,$); -#3580=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_95_74','Roofing edges and junction systems',#3570,$,$); -#3581=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_95_95','Wood shake or shingle roofing systems',#3570,$,$); -#3582=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42','Floor covering and finishing systems',#3326,$,$); -#3583=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_10','Calcium sulfate-based screed systems',#3582,$,$); -#3584=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_10_10','Bonded calcium sulfate-based screed systems',#3583,$,$); -#3585=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_10_30','Floating calcium sulfate-based screed systems',#3583,$,$); -#3586=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_10_90','Unbonded calcium sulfate-based screed systems',#3583,$,$); -#3587=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_15','Cementitious screed systems',#3582,$,$); -#3588=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_15_10','Bonded or partially bonded cementitious levelling screed systems',#3587,$,$); -#3589=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_15_15','Cementitious wearing screed systems',#3587,$,$); -#3590=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_15_30','Floating cementitious levelling screed systems',#3587,$,$); -#3591=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_15_90','Unbonded cementitious levelling screed systems',#3587,$,$); -#3592=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_20','Deck covering systems',#3582,$,$); -#3593=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_30','Floor paint systems',#3582,$,$); -#3594=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_30_30','Floor coating systems',#3593,$,$); -#3595=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_32','Floor tiling systems',#3582,$,$); -#3596=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_32_30','External floor tiling systems',#3595,$,$); -#3597=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_32_40','Internal floor tiling systems',#3595,$,$); -#3598=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_40','Ice rink floor systems',#3582,$,$); -#3599=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_50','Masonry flooring systems',#3582,$,$); -#3600=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_52','Mastic asphalt flooring and floor underlay systems',#3582,$,$); -#3601=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_52_50','Mastic asphalt flooring systems',#3600,$,$); -#3602=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_52_52','Mastic asphalt floor underlay systems',#3600,$,$); -#3603=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_54','Monolithic flooring systems',#3582,$,$); -#3604=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_54_75','Resin flooring systems',#3603,$,$); -#3605=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_72','Resilient and textile floor covering systems',#3582,$,$); -#3606=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_72_05','Adhesive-fixed rolled carpet systems',#3605,$,$); -#3607=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_72_10','Carpet tile systems',#3605,$,$); -#3608=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_72_25','Edge-fixed carpet systems',#3605,$,$); -#3609=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_72_72','Resilient sheet floor covering systems',#3605,$,$); -#3610=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_72_75','Resilient tile floor covering systems',#3605,$,$); -#3611=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_90','Terrazzo floor tiling and screed systems',#3582,$,$); -#3612=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_90_90','Terrazzo floor covering systems',#3611,$,$); -#3613=IFCCLASSIFICATIONREFERENCE($,'Ss_30_45','Pavement covering and finishing systems',#3326,$,$); -#3614=IFCCLASSIFICATIONREFERENCE($,'Ss_30_47','Ceiling and soffit covering and finishing systems',#3326,$,$); -#3615=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60','Roof, floor and paving accessory systems',#3326,$,$); -#3616=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_30','Floor feature systems',#3615,$,$); -#3617=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_30_26','Entrance matting systems',#3616,$,$); -#3618=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_50','Metal sheet roof flashing systems',#3615,$,$); -#3619=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_50_03','Aluminium roof flashing systems',#3618,$,$); -#3620=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_50_04','Aluminium roof weathering systems',#3618,$,$); -#3621=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_50_11','Carbon steel roof flashing systems',#3618,$,$); -#3622=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_50_12','Carbon steel roof weathering systems',#3618,$,$); -#3623=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_50_19','Copper roof flashing systems',#3618,$,$); -#3624=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_50_20','Copper roof weathering systems',#3618,$,$); -#3625=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_50_47','Lead roof flashing systems',#3618,$,$); -#3626=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_50_48','Lead roof weathering systems',#3618,$,$); -#3627=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_50_84','Stainless steel roof flashing systems',#3618,$,$); -#3628=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_50_85','Stainless steel roof weathering systems',#3618,$,$); -#3629=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_50_98','Zinc roof flashing systems',#3618,$,$); -#3630=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_50_99','Zinc roof weathering systems',#3618,$,$); -#3631=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_70','Roof feature systems',#3615,$,$); -#3632=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75','Roof, floor and paving drainage systems',#3326,$,$); -#3633=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_40','Kerb and channel systems',#3632,$,$); -#3634=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_40_30','Footway grating systems',#3633,$,$); -#3635=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_40_50','Multi unit surface drainage channel systems',#3633,$,$); -#3636=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_40_75','Single unit surface drainage channel systems',#3633,$,$); -#3637=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_45','Kerb and traffic separation systems',#3632,$,$); -#3638=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_45_03','Asphalt kerb systems',#3637,$,$); -#3639=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_45_15','Concrete kerb systems',#3637,$,$); -#3640=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_45_20','Demarcation paving systems',#3637,$,$); -#3641=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_45_45','Light duty kerb systems',#3637,$,$); -#3642=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_45_55','Multi unit traffic calming systems',#3637,$,$); -#3643=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_45_65','Precast kerb systems',#3637,$,$); -#3644=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_45_80','Single unit traffic calming systems',#3637,$,$); -#3645=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_45_85','Traffic kerb systems',#3637,$,$); -#3646=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_45_86','Traffic separation systems',#3637,$,$); -#3647=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_50','Metal sheet gutter lining systems',#3632,$,$); -#3648=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_50_05','Aluminium sheet gutter lining systems',#3647,$,$); -#3649=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_50_11','Carbon steel sheet gutter lining systems',#3647,$,$); -#3650=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_50_15','Copper sheet gutter lining systems',#3647,$,$); -#3651=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_50_45','Lead sheet gutter lining systems',#3647,$,$); -#3652=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_50_75','Stainless steel sheet gutter lining systems',#3647,$,$); -#3653=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_50_95','Zinc sheet gutter lining systems',#3647,$,$); -#3654=IFCCLASSIFICATIONREFERENCE($,'Ss_30_95','Temporary roof, floor and paving systems',#3326,$,$); -#3655=IFCCLASSIFICATIONREFERENCE($,'Ss_32','Damp proofing, waterproofing and plaster finishing systems',#2695,$,$); -#3656=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20','Damp proofing systems',#3655,$,$); -#3657=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_20','Damp proof courses renewal and insertion systems',#3656,$,$); -#3658=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_20_15','Chemical injection damp proof course systems',#3657,$,$); -#3659=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_20_62','Physical insertion horizontal damp proof course systems',#3657,$,$); -#3660=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_20_63','Physical insertion horizontal or stepped cavity tray systems',#3657,$,$); -#3661=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_20_64','Physical insertion proprietary rising damp remedial systems',#3657,$,$); -#3662=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_20_65','Physical insertion vertical damp proof course systems',#3657,$,$); -#3663=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30','Floor damp proofing systems',#3656,$,$); -#3664=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_10','Cementitious mortar slurry floor damp proofing systems',#3663,$,$); -#3665=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_15','Cold-applied liquid floor damp proofing systems',#3663,$,$); -#3666=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_30','Fully-bonded bitumen membrane overslab damp proofing systems',#3663,$,$); -#3667=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_35','Fully-bonded bitumen membrane underslab damp proofing systems',#3663,$,$); -#3668=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_40','Hot-applied liquid floor damp proofing systems',#3663,$,$); -#3669=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_45','Loose-laid bitumen membrane overslab damp proofing systems',#3663,$,$); -#3670=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_46','Loose-laid bitumen membrane underslab damp proofing systems',#3663,$,$); -#3671=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_48','Loose-laid polyethylene membrane oversite damp proofing systems',#3663,$,$); -#3672=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_50','Loose-laid polyethylene membrane overslab damp proofing systems',#3663,$,$); -#3673=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_51','Loose-laid polyethylene membrane underslab damp proofing systems',#3663,$,$); -#3674=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_55','Mastic asphalt floor damp proofing systems',#3663,$,$); -#3675=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_60','Plastics studded membrane floor damp proofing systems',#3663,$,$); -#3676=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_65','Pre-applied anchored membrane underslab damp proofing systems',#3663,$,$); -#3677=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_75','Self-adhesive bitumen membrane floor damp proofing systems',#3663,$,$); -#3678=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_95','Wall damp proofing systems',#3656,$,$); -#3679=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_95_10','Cementitious mortar slurry internal wall damp proofing systems',#3678,$,$); -#3680=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_95_15','Cold-applied liquid internal wall damp proofing systems',#3678,$,$); -#3681=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_95_65','Plastics studded membrane internal wall damp-proofing systems',#3678,$,$); -#3682=IFCCLASSIFICATIONREFERENCE($,'Ss_32_46','Lath and plaster systems',#3655,$,$); -#3683=IFCCLASSIFICATIONREFERENCE($,'Ss_32_46_50','Metal lathing and anchored mesh reinforcement systems',#3682,$,$); -#3684=IFCCLASSIFICATIONREFERENCE($,'Ss_32_46_50_05','Anchored mesh reinforcement systems',#3683,$,$); -#3685=IFCCLASSIFICATIONREFERENCE($,'Ss_32_46_50_50','Metal lathing casing systems',#3683,$,$); -#3686=IFCCLASSIFICATIONREFERENCE($,'Ss_32_46_50_51','Metal lathing on framing systems',#3683,$,$); -#3687=IFCCLASSIFICATIONREFERENCE($,'Ss_32_46_50_52','Metal lathing on hangers, bearers and runners systems',#3683,$,$); -#3688=IFCCLASSIFICATIONREFERENCE($,'Ss_32_46_50_53','Metal lathing on solid substrate systems',#3683,$,$); -#3689=IFCCLASSIFICATIONREFERENCE($,'Ss_32_46_65','Plaster coating systems',#3682,$,$); -#3690=IFCCLASSIFICATIONREFERENCE($,'Ss_32_46_65_15','Clay plaster systems',#3689,$,$); -#3691=IFCCLASSIFICATIONREFERENCE($,'Ss_32_46_65_55','Multicoat plaster systems',#3689,$,$); -#3692=IFCCLASSIFICATIONREFERENCE($,'Ss_32_46_65_58','One coat plaster systems',#3689,$,$); -#3693=IFCCLASSIFICATIONREFERENCE($,'Ss_32_46_65_90','Tiling and mosaic plaster substrate systems',#3689,$,$); -#3694=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80','Waterproofing and tanking systems',#3655,$,$); -#3695=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_03','Applied waterproofing and tanking systems',#3694,$,$); -#3696=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_03_08','Bridge deck liquid sprayed systems',#3695,$,$); -#3697=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_03_10','Cementitious proprietary mortar slurry tanking systems',#3695,$,$); -#3698=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_03_12','Cementitious site-batched-and-mixed mortar tanking systems',#3695,$,$); -#3699=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_03_14','Cold-applied liquid external tanking systems',#3695,$,$); -#3700=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_03_16','Cold-applied liquid sandwiched tanking systems',#3695,$,$); -#3701=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_03_18','Crystallization-active cementitious mortar dry shake tanking systems',#3695,$,$); -#3702=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_03_20','Crystallization-active cementitious mortar slurry tanking systems',#3695,$,$); -#3703=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_03_40','Interstitial grouting systems',#3695,$,$); -#3704=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_03_50','Mastic asphalt external tanking systems',#3695,$,$); -#3705=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_03_52','Mastic asphalt sandwiched tanking systems',#3695,$,$); -#3706=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_03_54','Mastic asphalt tank lining systems',#3695,$,$); -#3707=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_03_90','Tunnel spray-applied membrane systems',#3695,$,$); -#3708=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79','Sheeted waterproofing and tanking systems',#3694,$,$); -#3709=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_08','Bridge deck sheet systems',#3708,$,$); -#3710=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_30','Fully bonded bitumen membrane external tanking systems',#3708,$,$); -#3711=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_32','Fully bonded bitumen membrane sandwiched tanking systems',#3708,$,$); -#3712=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_33','Fully bonded flexible sheet membrane waterproofing systems',#3708,$,$); -#3713=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_35','Ground supported water retention sheet lining systems',#3708,$,$); -#3714=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_36','Hard rigid plastics sheet membrane waterproofing systems',#3708,$,$); -#3715=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_40','High density plastics studded membrane cavity drain waterproofing systems',#3708,$,$); -#3716=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_45','Loose-laid bentonite membrane external or sandwiched tanking systems',#3708,$,$); -#3717=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_75','Self-adhesive bitumen membrane external tanking systems',#3708,$,$); -#3718=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_77','Self-adhesive bitumen membrane sandwiched tanking systems',#3708,$,$); -#3719=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_84','Steel membrane waterproofing systems',#3708,$,$); -#3720=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_85','Structure supported water retention sheet lining systems',#3708,$,$); -#3721=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_90','Tunnel sheet membrane systems',#3708,$,$); -#3722=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_92','Unbonded flexible sheet membrane waterproofing systems',#3708,$,$); -#3723=IFCCLASSIFICATIONREFERENCE($,'Ss_35','Stair and ramp systems',#2695,$,$); -#3724=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10','Stair and ramp structure systems',#3723,$,$); -#3725=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_25','External stair and ramp systems',#3724,$,$); -#3726=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_25_34','Ground bearing external ramp systems',#3725,$,$); -#3727=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_25_35','Ground bearing external stair systems',#3725,$,$); -#3728=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_25_83','Suspended external ramp systems',#3725,$,$); -#3729=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_25_85','Suspended external stair systems',#3725,$,$); -#3730=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_30','Fixed utilitarian access systems',#3724,$,$); -#3731=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_30_15','Companionway ladder systems',#3730,$,$); -#3732=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_30_40','Industrial stair systems',#3730,$,$); -#3733=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_30_60','Permanently-fixed roof ladder systems',#3730,$,$); -#3734=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_30_62','Permanently-fixed vertical ladder systems',#3730,$,$); -#3735=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_30_95','Working platform and walkway systems',#3730,$,$); -#3736=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_40','Internal stair and ramp systems',#3724,$,$); -#3737=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_40_20','Curved internal stair systems',#3736,$,$); -#3738=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_40_40','Internal ramp systems',#3736,$,$); -#3739=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_40_42','Internal stair systems',#3736,$,$); -#3740=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_40_84','Straight internal stair systems',#3736,$,$); -#3741=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_50','Marine and waterside ramp systems',#3724,$,$); -#3742=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_50_29','Fixed ramp systems',#3741,$,$); -#3743=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_50_31','Floating pontoon ramp systems',#3741,$,$); -#3744=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_50_42','Integral pontoon ramp systems',#3741,$,$); -#3745=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_85','Structural stair and ramp systems',#3724,$,$); -#3746=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_85_15','Concrete stair or ramp systems',#3745,$,$); -#3747=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_85_35','Heavy steel stair or ramp systems',#3745,$,$); -#3748=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_85_65','Precast concrete stair or ramp systems',#3745,$,$); -#3749=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_85_90','Timber stair or ramp systems',#3745,$,$); -#3750=IFCCLASSIFICATIONREFERENCE($,'Ss_35_30','Stair and ramp opening systems',#3723,$,$); -#3751=IFCCLASSIFICATIONREFERENCE($,'Ss_35_30_15','Concrete stair and ramp glazing systems',#3750,$,$); -#3752=IFCCLASSIFICATIONREFERENCE($,'Ss_35_30_15_15','Concrete stair tread glazing systems',#3751,$,$); -#3753=IFCCLASSIFICATIONREFERENCE($,'Ss_35_40','Stair and ramp covering and finishing systems',#3723,$,$); -#3754=IFCCLASSIFICATIONREFERENCE($,'Ss_35_40_82','Stair carpeting systems',#3753,$,$); -#3755=IFCCLASSIFICATIONREFERENCE($,'Ss_35_40_82_05','Adhesive-fixed stair carpeting systems',#3754,$,$); -#3756=IFCCLASSIFICATIONREFERENCE($,'Ss_35_95','Temporary stair and ramp systems',#3723,$,$); -#3757=IFCCLASSIFICATIONREFERENCE($,'Ss_37','Tunnel, shaft, vessel and tower systems',#2695,$,$); -#3758=IFCCLASSIFICATIONREFERENCE($,'Ss_37_14','Chute systems',#3757,$,$); -#3759=IFCCLASSIFICATIONREFERENCE($,'Ss_37_14_10','Bulk material chute systems',#3758,$,$); -#3760=IFCCLASSIFICATIONREFERENCE($,'Ss_37_14_25','Escape chute systems',#3758,$,$); -#3761=IFCCLASSIFICATIONREFERENCE($,'Ss_37_14_70','Refuse and linen chute systems',#3758,$,$); -#3762=IFCCLASSIFICATIONREFERENCE($,'Ss_37_14_70_08','Built-in linen chute systems',#3761,$,$); -#3763=IFCCLASSIFICATIONREFERENCE($,'Ss_37_14_70_10','Built-in refuse chute systems',#3761,$,$); -#3764=IFCCLASSIFICATIONREFERENCE($,'Ss_37_14_70_63','Post-fixed linen chute systems',#3761,$,$); -#3765=IFCCLASSIFICATIONREFERENCE($,'Ss_37_14_70_65','Post-fixed refuse chute systems',#3761,$,$); -#3766=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16','Vessel and trench systems',#3757,$,$); -#3767=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_02','Above ground pool systems',#3766,$,$); -#3768=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_05','Basement water retaining systems',#3766,$,$); -#3769=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_10','Bund systems',#3766,$,$); -#3770=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_10_32','Fuel tank bund systems',#3769,$,$); -#3771=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_50','Metal and plastics water retaining systems',#3766,$,$); -#3772=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_65','Pond and wetland systems',#3766,$,$); -#3773=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_65_40','Informal pond systems',#3772,$,$); -#3774=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_65_70','Raised formal pond systems',#3772,$,$); -#3775=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_65_85','Submerged formal pond systems',#3772,$,$); -#3776=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_65_95','Wetland systems',#3772,$,$); -#3777=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_75','Silo systems',#3766,$,$); -#3778=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_90','Trench, pipeway and pit systems',#3766,$,$); -#3779=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_90_11','Cable protection systems',#3778,$,$); -#3780=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_90_28','External underground service duct systems',#3778,$,$); -#3781=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_90_63','Pit systems',#3778,$,$); -#3782=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_95','Watertight structural systems',#3766,$,$); -#3783=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_95_78','Sewage treatment vessel systems',#3782,$,$); -#3784=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17','Tower, chimney and mast systems',#3757,$,$); -#3785=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_13','Chimney systems',#3784,$,$); -#3786=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_13_50','Masonry chimney stack systems',#3785,$,$); -#3787=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_13_65','Pollution control systems',#3785,$,$); -#3788=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_35','Gantry systems',#3784,$,$); -#3789=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_35_11','Cantilever gantry systems',#3788,$,$); -#3790=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_35_32','Full span gantry systems',#3788,$,$); -#3791=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_35_50','Mast arm sign gantry systems',#3788,$,$); -#3792=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_35_60','Portal sign gantry systems',#3788,$,$); -#3793=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_35_70','Reefer gantry systems',#3788,$,$); -#3794=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_45','Lattice tower and pylon systems',#3784,$,$); -#3795=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_50','Mast and pole systems',#3784,$,$); -#3796=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_50_54','Multi-function pole systems',#3795,$,$); -#3797=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_50_72','Road mast systems',#3795,$,$); -#3798=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_90','Tower systems',#3784,$,$); -#3799=IFCCLASSIFICATIONREFERENCE($,'Ss_37_40','Tunnel, shaft, vessel and tower covering and finishing systems',#3757,$,$); -#3800=IFCCLASSIFICATIONREFERENCE($,'Ss_37_40_85','Swimming pool tiling systems',#3799,$,$); -#3801=IFCCLASSIFICATIONREFERENCE($,'Ss_37_40_85_83','Swimming pool floor tiling systems',#3800,$,$); -#3802=IFCCLASSIFICATIONREFERENCE($,'Ss_37_40_85_85','Swimming pool wall tiling systems',#3800,$,$); -#3803=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50','Shaft and tunnel structural systems',#3757,$,$); -#3804=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_80','Shaft structure systems',#3803,$,$); -#3805=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_80_50','Masonry lined shaft systems',#3804,$,$); -#3806=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_80_71','Reinforced concrete shaft structure systems',#3804,$,$); -#3807=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_80_77','Segmental shaft structure systems',#3804,$,$); -#3808=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_80_83','Sprayed concrete shaft lining systems',#3804,$,$); -#3809=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_80_90','Unit lined shaft systems',#3804,$,$); -#3810=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_92','Tunnel structure systems',#3803,$,$); -#3811=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_92_11','Cast concrete tunnel invert systems',#3810,$,$); -#3812=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_92_15','Colliery arch tunnel or adit systems',#3810,$,$); -#3813=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_92_50','Masonry tunnel structure systems',#3810,$,$); -#3814=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_92_64','Primary regulating layer sprayed concrete lining systems',#3810,$,$); -#3815=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_92_66','Primary sprayed concrete lining systems',#3810,$,$); -#3816=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_92_71','Reinforced concrete tunnel structure systems',#3810,$,$); -#3817=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_92_75','Secondary cast concrete lining systems',#3810,$,$); -#3818=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_92_76','Secondary regulating layer sprayed concrete lining systems',#3810,$,$); -#3819=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_92_77','Secondary sprayed concrete lining systems',#3810,$,$); -#3820=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_92_79','Sectional tunnel structure systems',#3810,$,$); -#3821=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_92_83','Sprayed concrete tunnel lining systems',#3810,$,$); -#3822=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_92_90','Unit lined tunnel systems',#3810,$,$); -#3823=IFCCLASSIFICATIONREFERENCE($,'Ss_37_55','Tunnel and shaft opening systems',#3757,$,$); -#3824=IFCCLASSIFICATIONREFERENCE($,'Ss_37_55_60','Opening frame systems',#3823,$,$); -#3825=IFCCLASSIFICATIONREFERENCE($,'Ss_37_55_60_90','Tunnel opening frame systems',#3824,$,$); -#3826=IFCCLASSIFICATIONREFERENCE($,'Ss_37_60','Tunnel, shaft, vessel and tower accessory systems',#3757,$,$); -#3827=IFCCLASSIFICATIONREFERENCE($,'Ss_37_95','Temporary tunnel, shaft, vessel and tower systems',#3757,$,$); -#3828=IFCCLASSIFICATIONREFERENCE($,'Ss_40','Signage, fittings, furnishings and equipment (FF&E) and general finishing systems',#2695,$,$); -#3829=IFCCLASSIFICATIONREFERENCE($,'Ss_40_05','Modular systems',#3828,$,$); -#3830=IFCCLASSIFICATIONREFERENCE($,'Ss_40_05_80','Sanitary modular systems',#3829,$,$); -#3831=IFCCLASSIFICATIONREFERENCE($,'Ss_40_05_80_10','Bathroom pod systems',#3830,$,$); -#3832=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10','Signage systems',#3828,$,$); -#3833=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_20','Direction signage systems',#3832,$,$); -#3834=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_20_70','Route marker signage systems',#3833,$,$); -#3835=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_20_96','Wayfinding signage systems',#3833,$,$); -#3836=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_25','External signage and interpretation systems',#3832,$,$); -#3837=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_25_25','Electrical external signage systems',#3836,$,$); -#3838=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_25_30','Fixed external signage systems',#3836,$,$); -#3839=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_25_32','Free-standing external architectural signage systems',#3836,$,$); -#3840=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_30','Fire and safety signage systems',#3832,$,$); -#3841=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_30_20','Emergency ''do not enter'' signage systems',#3840,$,$); -#3842=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_30_25','Evacuation and safe condition signage systems',#3840,$,$); -#3843=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_30_27','Evacuation and safety way guidance systems',#3840,$,$); -#3844=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_30_30','Fire signage systems',#3840,$,$); -#3845=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_30_36','Hazard signage systems',#3840,$,$); -#3846=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_30_70','Regulatory signage systems',#3840,$,$); -#3847=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_30_75','Safety signage systems',#3840,$,$); -#3848=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_30_93','Warning signage systems',#3840,$,$); -#3849=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_30_95','Water safety signage systems',#3840,$,$); -#3850=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_35','Identification signage systems',#3832,$,$); -#3851=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_35_10','Building signage systems',#3850,$,$); -#3852=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_35_70','Room signage systems',#3850,$,$); -#3853=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_35_80','Spaces signage systems',#3850,$,$); -#3854=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_40','Internal architectural signage systems',#3832,$,$); -#3855=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_40_25','Electrical internal architectural signage systems',#3854,$,$); -#3856=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_40_30','Fixed internal architectural signage systems',#3854,$,$); -#3857=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_40_32','Free-standing internal architectural signage systems',#3854,$,$); -#3858=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_50','Information signage systems',#3832,$,$); -#3859=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_50_03','Advertising signage systems',#3858,$,$); -#3860=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_50_05','Advisory signage systems',#3858,$,$); -#3861=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_50_22','Descriptive signage systems',#3858,$,$); -#3862=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_50_24','Directory signage systems',#3858,$,$); -#3863=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_50_42','Interpretive signage systems',#3858,$,$); -#3864=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_90','Traffic signage and marking systems',#3832,$,$); -#3865=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_90_03','Air traffic signage systems',#3864,$,$); -#3866=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_90_18','Crossing road marking systems',#3864,$,$); -#3867=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_90_20','Cycle traffic signage systems',#3864,$,$); -#3868=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_90_23','Diagrammatic road marking systems',#3864,$,$); -#3869=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_90_36','Hatched road marking systems',#3864,$,$); -#3870=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_90_50','Marine traffic signage systems',#3864,$,$); -#3871=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_90_70','Rail traffic signage systems',#3864,$,$); -#3872=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_90_72','Road traffic signage systems',#3864,$,$); -#3873=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15','General fittings, furnishings and equipment (FF&E) systems',#3828,$,$); -#3874=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_25','Catering FF&E systems',#3873,$,$); -#3875=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_25_15','Commercial catering FF&E systems',#3874,$,$); -#3876=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_25_20','Domestic catering FF&E systems',#3874,$,$); -#3877=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_35','General and joinery FF&E systems',#3873,$,$); -#3878=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_35_35','General FF&E systems',#3877,$,$); -#3879=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_35_50','Minor joinery systems',#3877,$,$); -#3880=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_46','Laundry FF&E systems',#3873,$,$); -#3881=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_46_15','Commercial laundry FF&E systems',#3880,$,$); -#3882=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_46_20','Domestic laundry FF&E systems',#3880,$,$); -#3883=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_58','Office equipment systems',#3873,$,$); -#3884=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_58_50','Meeting booth systems',#3883,$,$); -#3885=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75','Sanitary appliance systems',#3873,$,$); -#3886=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_05','Bath systems',#3885,$,$); -#3887=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_10','Bidet systems',#3885,$,$); -#3888=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_20','Disposal unit (slop hopper) systems',#3885,$,$); -#3889=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_25','Drinking fountain systems',#3885,$,$); -#3890=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_35','Health care macerator systems',#3885,$,$); -#3891=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_45','Janitorial unit systems',#3885,$,$); -#3892=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_75','Sanitary accessory systems',#3885,$,$); -#3893=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_76','Sauna package systems',#3885,$,$); -#3894=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_77','Scrub-up trough systems',#3885,$,$); -#3895=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_78','Shower area systems',#3885,$,$); -#3896=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_79','Shower cubicle systems',#3885,$,$); -#3897=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_80','Sink systems',#3885,$,$); -#3898=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_85','Steam bath package systems',#3885,$,$); -#3899=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_92','Urinal systems',#3885,$,$); -#3900=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_94','Wash basin systems',#3885,$,$); -#3901=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_96','Wash fountain systems',#3885,$,$); -#3902=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_98','Wash trough systems',#3885,$,$); -#3903=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_77','Sauna FF&E systems',#3873,$,$); -#3904=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_90','Toilet systems',#3873,$,$); -#3905=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_90_05','Accessible WC package systems',#3904,$,$); -#3906=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_90_85','Squatting WC systems',#3904,$,$); -#3907=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_90_95','Waterless toilet systems',#3904,$,$); -#3908=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_90_96','WC and wash basin combination systems',#3904,$,$); -#3909=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_90_97','WC systems',#3904,$,$); -#3910=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_90_98','WC wash and dry combination systems',#3904,$,$); -#3911=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20','Administrative, commercial and protective service FF&E systems',#3828,$,$); -#3912=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_01','Administrative FF&E systems',#3911,$,$); -#3913=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_01_27','Embassy FF&E systems',#3912,$,$); -#3914=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_01_60','Office FF&E systems',#3912,$,$); -#3915=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_01_71','Reception FF&E systems',#3912,$,$); -#3916=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_15','Commercial FF&E systems',#3911,$,$); -#3917=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_15_71','Retail FF&E systems',#3916,$,$); -#3918=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_15_89','Trading floor FF&E systems',#3916,$,$); -#3919=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_30','External public realm FF&E systems',#3911,$,$); -#3920=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_30_01','Acceptance and dispensing systems',#3919,$,$); -#3921=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_30_20','Cycle parking equipment systems',#3919,$,$); -#3922=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_30_28','External furniture systems',#3919,$,$); -#3923=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_30_30','Fixed bin systems',#3919,$,$); -#3924=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_30_65','Playground equipment systems',#3919,$,$); -#3925=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_65','Protective service FF&E systems',#3911,$,$); -#3926=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_65_22','Detention FF&E systems',#3925,$,$); -#3927=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_65_25','Emergency shelter FF&E systems',#3925,$,$); -#3928=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_65_46','Law court FF&E systems',#3925,$,$); -#3929=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25','Cultural, educational, scientific and information FF&E systems',#3828,$,$); -#3930=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_20','Cultural FF&E systems',#3929,$,$); -#3931=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_20_02','Aquarium FF&E systems',#3930,$,$); -#3932=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_20_03','Art gallery FF&E systems',#3930,$,$); -#3933=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_20_04','Artwork systems',#3930,$,$); -#3934=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_20_05','Auditorium FF&E systems',#3930,$,$); -#3935=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_20_22','Display FF&E systems',#3930,$,$); -#3936=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_20_28','Exhibition FF&E systems',#3930,$,$); -#3937=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_20_85','Studio FF&E systems',#3930,$,$); -#3938=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_20_90','Theatre FF&E systems',#3930,$,$); -#3939=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_26','Education and information FF&E systems',#3929,$,$); -#3940=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_26_15','Classroom FF&E systems',#3939,$,$); -#3941=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_26_47','Library FF&E systems',#3939,$,$); -#3942=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_32','Funerary FF&E systems',#3929,$,$); -#3943=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_32_12','Cemetery equipment systems',#3942,$,$); -#3944=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_71','Religious FF&E systems',#3929,$,$); -#3945=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_71_11','Cathedral, church and chapel FF&E systems',#3944,$,$); -#3946=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_71_52','Mosque FF&E systems',#3944,$,$); -#3947=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_71_86','Synagogue FF&E systems',#3944,$,$); -#3948=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_71_90','Temple FF&E systems',#3944,$,$); -#3949=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_75','Scientific FF&E systems',#3929,$,$); -#3950=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_75_21','Dark room FF&E systems',#3949,$,$); -#3951=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_75_45','Laboratory FF&E systems',#3949,$,$); -#3952=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_75_58','Observatory FF&E systems',#3949,$,$); -#3953=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_80','Stage FF&E systems',#3929,$,$); -#3954=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_80_90','Tension wire grid systems',#3953,$,$); -#3955=IFCCLASSIFICATIONREFERENCE($,'Ss_40_30','Industrial and agricultural FF&E systems',#3828,$,$); -#3956=IFCCLASSIFICATIONREFERENCE($,'Ss_40_30_02','Agricultural FF&E systems',#3955,$,$); -#3957=IFCCLASSIFICATIONREFERENCE($,'Ss_40_30_02_37','Horticultural FF&E systems',#3956,$,$); -#3958=IFCCLASSIFICATIONREFERENCE($,'Ss_40_30_02_47','Livestock FF&E systems',#3956,$,$); -#3959=IFCCLASSIFICATIONREFERENCE($,'Ss_40_30_42','Industrial FF&E systems',#3955,$,$); -#3960=IFCCLASSIFICATIONREFERENCE($,'Ss_40_30_42_29','Factory FF&E systems',#3959,$,$); -#3961=IFCCLASSIFICATIONREFERENCE($,'Ss_40_30_42_52','Mine FF&E systems',#3959,$,$); -#3962=IFCCLASSIFICATIONREFERENCE($,'Ss_40_30_42_58','Offshore platform FF&E systems',#3959,$,$); -#3963=IFCCLASSIFICATIONREFERENCE($,'Ss_40_30_42_96','Warehouse FF&E systems',#3959,$,$); -#3964=IFCCLASSIFICATIONREFERENCE($,'Ss_40_30_85','Static permanent access and safety equipment systems',#3955,$,$); -#3965=IFCCLASSIFICATIONREFERENCE($,'Ss_40_30_85_55','Netting systems',#3964,$,$); -#3966=IFCCLASSIFICATIONREFERENCE($,'Ss_40_45','Living space FF&E systems',#3828,$,$); -#3967=IFCCLASSIFICATIONREFERENCE($,'Ss_40_45_37','Hotel living space FF&E systems',#3966,$,$); -#3968=IFCCLASSIFICATIONREFERENCE($,'Ss_40_45_37_28','External FF&E systems',#3967,$,$); -#3969=IFCCLASSIFICATIONREFERENCE($,'Ss_40_45_37_36','Hotel bedroom FF&E systems',#3967,$,$); -#3970=IFCCLASSIFICATIONREFERENCE($,'Ss_40_45_37_38','Hotel dining room FF&E systems',#3967,$,$); -#3971=IFCCLASSIFICATIONREFERENCE($,'Ss_40_45_37_45','Kitchen FF&E systems',#3967,$,$); -#3972=IFCCLASSIFICATIONREFERENCE($,'Ss_40_45_37_47','Lounge FF&E systems',#3967,$,$); -#3973=IFCCLASSIFICATIONREFERENCE($,'Ss_40_45_70','Residential living space FF&E systems',#3966,$,$); -#3974=IFCCLASSIFICATIONREFERENCE($,'Ss_40_45_70_07','Bedroom FF&E systems',#3973,$,$); -#3975=IFCCLASSIFICATIONREFERENCE($,'Ss_40_45_70_22','Dining room FF&E systems',#3973,$,$); -#3976=IFCCLASSIFICATIONREFERENCE($,'Ss_40_45_70_24','Domestic kitchen FF&E systems',#3973,$,$); -#3977=IFCCLASSIFICATIONREFERENCE($,'Ss_40_45_70_33','Garden FF&E systems',#3973,$,$); -#3978=IFCCLASSIFICATIONREFERENCE($,'Ss_40_45_70_47','Living room FF&E systems',#3973,$,$); -#3979=IFCCLASSIFICATIONREFERENCE($,'Ss_40_50','Medical, health and welfare FF&E systems',#3828,$,$); -#3980=IFCCLASSIFICATIONREFERENCE($,'Ss_40_50_50','Medical and health FF&E systems',#3979,$,$); -#3981=IFCCLASSIFICATIONREFERENCE($,'Ss_40_50_50_18','Cr\X2\00E8\X0\che FF&E systems',#3980,$,$); -#3982=IFCCLASSIFICATIONREFERENCE($,'Ss_40_50_50_37','Hospital ward FF&E systems',#3980,$,$); -#3983=IFCCLASSIFICATIONREFERENCE($,'Ss_40_50_50_50','Medical and dental surgery FF&E systems',#3980,$,$); -#3984=IFCCLASSIFICATIONREFERENCE($,'Ss_40_50_50_59','Operating theatre FF&E systems',#3980,$,$); -#3985=IFCCLASSIFICATIONREFERENCE($,'Ss_40_50_96','Welfare FF&E systems',#3979,$,$); -#3986=IFCCLASSIFICATIONREFERENCE($,'Ss_40_50_96_04','Animal welfare FF&E systems',#3985,$,$); -#3987=IFCCLASSIFICATIONREFERENCE($,'Ss_40_50_96_71','Rehabilitation FF&E systems',#3985,$,$); -#3988=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70','Recreational FF&E systems',#3828,$,$); -#3989=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_20','Casino FF&E systems',#3988,$,$); -#3990=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_55','Play FF&E systems',#3988,$,$); -#3991=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_55_10','Climbing equipment systems',#3990,$,$); -#3992=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_55_15','Combination play equipment systems',#3990,$,$); -#3993=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_55_35','Gymnastics and exercising equipment systems',#3990,$,$); -#3994=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_55_70','Rocking equipment systems',#3990,$,$); -#3995=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_55_73','Runway equipment systems',#3990,$,$); -#3996=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_55_75','Sand and water play equipment systems',#3990,$,$); -#3997=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_55_80','Slide equipment systems',#3990,$,$); -#3998=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_55_83','Spinning equipment systems',#3990,$,$); -#3999=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_55_85','Swinging equipment systems',#3990,$,$); -#4000=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_60','Pool FF&E systems',#3988,$,$); -#4001=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_60_15','Competitive swimming pool FF&E systems',#4000,$,$); -#4002=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_60_25','Diving pool FF&E systems',#4000,$,$); -#4003=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_60_45','Leisure swimming pool FF&E systems',#4000,$,$); -#4004=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_60_62','Pool transfer aid equipment systems',#4000,$,$); -#4005=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_65','Public house FF&E systems',#3988,$,$); -#4006=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_70','Restaurant FF&E systems',#3988,$,$); -#4007=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_75','Sports FF&E systems',#3988,$,$); -#4008=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_75_05','Ball court FF&E systems',#4007,$,$); -#4009=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_75_20','Cycle course FF&E systems',#4007,$,$); -#4010=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_75_27','Equestrian equipment systems',#4007,$,$); -#4011=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_75_50','Multi-use games area FF&E systems',#4007,$,$); -#4012=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_75_80','Skate park FF&E systems',#4007,$,$); -#4013=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_75_85','Sports pitch FF&E systems',#4007,$,$); -#4014=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_75_90','Trim trail FF&E systems',#4007,$,$); -#4015=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_80','Stadium FF&E systems',#3988,$,$); -#4016=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_95','Wildlife, eco site and nature conservation FF&E systems',#3988,$,$); -#4017=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85','Transport FF&E systems',#3828,$,$); -#4018=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_01','Aerospace FF&E systems',#4017,$,$); -#4019=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_01_01','Aircraft fire training simulation systems',#4018,$,$); -#4020=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_11','Cable transport FF&E systems',#4017,$,$); -#4021=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_50','Marine and waterway FF&E systems',#4017,$,$); -#4022=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_50_95','Waterside FF&E systems',#4021,$,$); -#4023=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_70','Rail FF&E systems',#4017,$,$); -#4024=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_70_60','Passenger concourse FF&E systems',#4023,$,$); -#4025=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_72','Road FF&E systems',#4017,$,$); -#4026=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_72_11','Car park equipment systems',#4025,$,$); -#4027=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_72_33','Garage FF&E systems',#4025,$,$); -#4028=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_75','Rolling stock depot systems',#4017,$,$); -#4029=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_75_07','Bogie handling systems',#4028,$,$); -#4030=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_75_15','Controlled emission toilet (CET) systems',#4028,$,$); -#4031=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_75_24','Drop systems',#4028,$,$); -#4032=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_75_65','Press systems',#4028,$,$); -#4033=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_75_70','Rail lifting systems',#4028,$,$); -#4034=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_75_75','Sand feeding systems',#4028,$,$); -#4035=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_75_97','Wheel lathe systems',#4028,$,$); -#4036=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90','General finishing systems',#3828,$,$); -#4037=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_05','Anodizing systems',#4036,$,$); -#4038=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_05_05','Aluminium anodic coating systems',#4037,$,$); -#4039=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_35','Hot dip galvanizing systems',#4036,$,$); -#4040=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_40','Intumescent systems',#4036,$,$); -#4041=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_40_40','Intumescent casting systems',#4040,$,$); -#4042=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_40_42','Intumescent coating systems',#4040,$,$); -#4043=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_60','Painting and clear finishing systems',#4036,$,$); -#4044=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_60_05','Anti-graffiti coating systems',#4043,$,$); -#4045=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_60_20','Decorative varnish or lacquer systems',#4043,$,$); -#4046=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_60_22','Decorative wood stain or dye systems',#4043,$,$); -#4047=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_60_55','Multi-colour coating systems',#4043,$,$); -#4048=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_60_60','Oil gilding systems',#4043,$,$); -#4049=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_60_65','Plastic texture coating systems',#4043,$,$); -#4050=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_60_80','Solvent-borne paint systems',#4043,$,$); -#4051=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_60_85','Special coating systems',#4043,$,$); -#4052=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_60_94','Water-based anti-corrosion systems',#4043,$,$); -#4053=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_60_95','Waterborne paint systems',#4043,$,$); -#4054=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_65','Powder coating systems',#4036,$,$); -#4055=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_65_05','Powder coating for aluminium systems',#4054,$,$); -#4056=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_65_85','Powder coating for steel systems',#4054,$,$); -#4057=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_75','Services painting systems',#4036,$,$); -#4058=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_95','Wood preservative and fire retardant treatment systems',#4036,$,$); -#4059=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_95_30','Fire retardant treatment systems',#4058,$,$); -#4060=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_95_65','Preservative treatment systems',#4058,$,$); -#4061=IFCCLASSIFICATIONREFERENCE($,'Ss_40_95','Temporary signage and FF&E systems',#3828,$,$); -#4062=IFCCLASSIFICATIONREFERENCE($,'Ss_45','Flora and fauna systems',#2695,$,$); -#4063=IFCCLASSIFICATIONREFERENCE($,'Ss_45_05','Ecosystems',#4062,$,$); -#4064=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10','Flora and fauna control systems',#4062,$,$); -#4065=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_10','Bird, insect and vermin control systems',#4064,$,$); -#4066=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_10_04','Animal control systems',#4065,$,$); -#4067=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_10_10','Bird control systems',#4065,$,$); -#4068=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_10_14','Chemical termite protection systems',#4065,$,$); -#4069=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_10_40','Insect control systems',#4065,$,$); -#4070=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_10_64','Physical termite protection systems',#4065,$,$); -#4071=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_10_72','Rodent control systems',#4065,$,$); -#4072=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_40','Invasive microbial and invertebrate control systems',#4064,$,$); -#4073=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_40_40','Invertebrate control systems',#4072,$,$); -#4074=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_40_50','Microbial control systems',#4072,$,$); -#4075=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_95','Vegetation control systems',#4064,$,$); -#4076=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_95_50','Moss, algae and lichen control systems',#4075,$,$); -#4077=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_95_72','Rooted plants on hard surfaces control systems',#4075,$,$); -#4078=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_95_80','Selective vegetation control systems',#4075,$,$); -#4079=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_95_81','Self-clinging plants on hard surfaces control systems',#4075,$,$); -#4080=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_95_83','Site vegetation control systems',#4075,$,$); -#4081=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_95_95','Waterborne vegetation control systems',#4075,$,$); -#4082=IFCCLASSIFICATIONREFERENCE($,'Ss_45_30','Aquatic flora systems',#4062,$,$); -#4083=IFCCLASSIFICATIONREFERENCE($,'Ss_45_30_05','Aquatic and wetland planting systems',#4082,$,$); -#4084=IFCCLASSIFICATIONREFERENCE($,'Ss_45_30_05_05','Aquatic planting systems',#4083,$,$); -#4085=IFCCLASSIFICATIONREFERENCE($,'Ss_45_30_05_50','Marginal planting systems',#4083,$,$); -#4086=IFCCLASSIFICATIONREFERENCE($,'Ss_45_30_05_70','Reedbed planting systems',#4083,$,$); -#4087=IFCCLASSIFICATIONREFERENCE($,'Ss_45_30_40','Hydroponic planting systems',#4082,$,$); -#4088=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35','Ground based flora systems',#4062,$,$); -#4089=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_05','Amenity and ornamental planting systems',#4088,$,$); -#4090=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_05_08','Bed-planted annual, perennial and bulb systems',#4089,$,$); -#4091=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_05_35','Grass-planted bulb and wildflower systems',#4089,$,$); -#4092=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_05_37','Grass-planted small tree and shrub systems',#4089,$,$); -#4093=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_05_42','Long-stem planted small tree and shrub systems',#4089,$,$); -#4094=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_05_62','Pit-planted climber systems',#4089,$,$); -#4095=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_05_64','Pit-planted perennial systems',#4089,$,$); -#4096=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_05_66','Pit-planted large tree systems',#4089,$,$); -#4097=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_05_67','Pit-planted small tree and shrub systems',#4089,$,$); -#4098=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_08','Biodiversity and environmental conservation systems',#4088,$,$); -#4099=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_08_29','Flora species introduction systems',#4098,$,$); -#4100=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_08_30','Flora species protection systems',#4098,$,$); -#4101=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_08_35','Habitat creation systems',#4098,$,$); -#4102=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_08_37','Habitat management and enhancement systems',#4098,$,$); -#4103=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_08_38','Habitat protection systems',#4098,$,$); -#4104=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_30','Forestry, biomass, hedging and roadside planting systems',#4088,$,$); -#4105=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_30_40','Hydraulic seeded tree and shrub systems',#4104,$,$); -#4106=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_30_55','Notch-planted tree and shrub systems',#4104,$,$); -#4107=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_30_62','Pit-planted tree and shrub systems',#4104,$,$); -#4108=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_30_72','Ridge and furrow-planted tree and shrub systems',#4104,$,$); -#4109=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_30_75','Seeded tree and shrub systems',#4104,$,$); -#4110=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_30_90','Trench-planted tree and shrub systems',#4104,$,$); -#4111=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_45','Lawn and meadow planting systems',#4088,$,$); -#4112=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_45_33','Grass and wildflower seeding systems',#4111,$,$); -#4113=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_45_35','Grass seeding systems',#4111,$,$); -#4114=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_45_40','Hydraulic seeding systems',#4111,$,$); -#4115=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_45_62','Plastics paving and turf systems',#4111,$,$); -#4116=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_45_65','Pre-seeded mat systems',#4111,$,$); -#4117=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_45_70','Reinforced grass planting systems',#4111,$,$); -#4118=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_45_90','Turf planting systems',#4111,$,$); -#4119=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40','Artificially supported flora systems',#4062,$,$); -#4120=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_28','External container planting systems',#4119,$,$); -#4121=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_28_25','External planter systems',#4120,$,$); -#4122=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_28_32','Free standing external container planting systems',#4120,$,$); -#4123=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_28_35','Hanging container planting systems',#4120,$,$); -#4124=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_28_85','External planting systems',#4120,$,$); -#4125=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_40','Internal container planting systems',#4119,$,$); -#4126=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_40_32','Free standing internal container planting systems',#4125,$,$); -#4127=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_40_34','Ground level internal container planting systems',#4125,$,$); -#4128=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_40_41','Internal hanging container planting systems',#4125,$,$); -#4129=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_40_42','Internal planter systems',#4125,$,$); -#4130=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_47','Living roof systems',#4119,$,$); -#4131=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_47_09','Brown roof systems',#4130,$,$); -#4132=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_47_28','Extensive green roof systems',#4130,$,$); -#4133=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_47_40','Intensive green roof systems',#4130,$,$); -#4134=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_47_75','Semi-intensive green roof systems',#4130,$,$); -#4135=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_95','Vertical planting systems',#4119,$,$); -#4136=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_95_08','Biofiltration vertical planting systems',#4135,$,$); -#4137=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_95_52','Membranous vertical planting systems',#4135,$,$); -#4138=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_95_54','Modular unit vertical planting systems',#4135,$,$); -#4139=IFCCLASSIFICATIONREFERENCE($,'Ss_45_50','Artificial flora systems',#4062,$,$); -#4140=IFCCLASSIFICATIONREFERENCE($,'Ss_45_50_05','Artificial planting systems',#4139,$,$); -#4141=IFCCLASSIFICATIONREFERENCE($,'Ss_45_50_05_40','Internal artificial planting systems',#4140,$,$); -#4142=IFCCLASSIFICATIONREFERENCE($,'Ss_45_60','Avian fauna systems',#4062,$,$); -#4143=IFCCLASSIFICATIONREFERENCE($,'Ss_45_65','Insectile fauna systems',#4062,$,$); -#4144=IFCCLASSIFICATIONREFERENCE($,'Ss_45_70','Mammalian fauna systems',#4062,$,$); -#4145=IFCCLASSIFICATIONREFERENCE($,'Ss_45_70_05','Animal conservation systems',#4144,$,$); -#4146=IFCCLASSIFICATIONREFERENCE($,'Ss_45_70_05_27','Animal road crossing systems',#4145,$,$); -#4147=IFCCLASSIFICATIONREFERENCE($,'Ss_45_70_05_29','Animal species introduction systems',#4145,$,$); -#4148=IFCCLASSIFICATIONREFERENCE($,'Ss_45_70_05_30','Animal species protection systems',#4145,$,$); -#4149=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75','Piscine fauna systems',#4062,$,$); -#4150=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30','Fish, eel and lamprey pass systems',#4149,$,$); -#4151=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30_03','Alaskan A baffle pass systems',#4150,$,$); -#4152=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30_06','Baffle and brush pass systems',#4150,$,$); -#4153=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30_09','Brush furnished baffle pass systems',#4150,$,$); -#4154=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30_13','Chevron bottom baffle pass systems',#4150,$,$); -#4155=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30_21','Deep notch and orifice pool pass systems',#4150,$,$); -#4156=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30_23','Deep notch no orifice pool pass systems',#4150,$,$); -#4157=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30_30','Fish pass systems',#4150,$,$); -#4158=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30_46','Larinier super active baffle pass systems',#4150,$,$); -#4159=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30_63','Plane baffle denil pass systems',#4150,$,$); -#4160=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30_65','Pool and orifice pass systems',#4150,$,$); -#4161=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30_67','Pool and traverse pass systems',#4150,$,$); -#4162=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30_77','Shallow v notch pool pass systems',#4150,$,$); -#4163=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30_94','Vertical slot pool pass systems',#4150,$,$); -#4164=IFCCLASSIFICATIONREFERENCE($,'Ss_45_80','Reptilian fauna systems',#4062,$,$); -#4165=IFCCLASSIFICATIONREFERENCE($,'Ss_45_85','Artificial fauna systems',#4062,$,$); -#4166=IFCCLASSIFICATIONREFERENCE($,'Ss_50','Disposal systems',#2695,$,$); -#4167=IFCCLASSIFICATIONREFERENCE($,'Ss_50_10','Gas waste collection and distribution systems',#4166,$,$); -#4168=IFCCLASSIFICATIONREFERENCE($,'Ss_50_10_45','Landfill gas collection and distribution systems',#4167,$,$); -#4169=IFCCLASSIFICATIONREFERENCE($,'Ss_50_10_95','Waste gas collection and distribution systems',#4167,$,$); -#4170=IFCCLASSIFICATIONREFERENCE($,'Ss_50_20','Non-aqueous liquid waste collection and distribution systems',#4166,$,$); -#4171=IFCCLASSIFICATIONREFERENCE($,'Ss_50_20_45','Landfill liquid collection and distribution systems',#4170,$,$); -#4172=IFCCLASSIFICATIONREFERENCE($,'Ss_50_20_90','Waste liquid fuel collection and distribution systems',#4170,$,$); -#4173=IFCCLASSIFICATIONREFERENCE($,'Ss_50_20_95','Waste process liquid collection and distribution systems',#4170,$,$); -#4174=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30','Building and land drainage collection systems',#4166,$,$); -#4175=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_02','Rainwater drainage systems',#4174,$,$); -#4176=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_02_28','External gravity rainwater drainage systems',#4175,$,$); -#4177=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_02_40','Internal gravity rainwater drainage systems',#4175,$,$); -#4178=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_02_65','Pressure-assisted full bore rainwater drainage systems',#4175,$,$); -#4179=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_02_80','Siphonic full bore rainwater drainage systems',#4175,$,$); -#4180=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_04','Above ground waste water drainage systems',#4174,$,$); -#4181=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_04_05','Basement waste water drainage systems',#4180,$,$); -#4182=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_04_15','Commercial catering waste water drainage systems',#4180,$,$); -#4183=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_04_95','Above ground external stack wastewater drainage systems',#4180,$,$); -#4184=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_04_97','Above ground internal stack wastewater drainage systems',#4180,$,$); -#4185=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_06','Below ground inspection systems',#4174,$,$); -#4186=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_06_06','Brick manhole systems',#4185,$,$); -#4187=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_06_08','Brick shallow inspection chamber systems',#4185,$,$); -#4188=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_06_10','Brick shallow silt trap and flow control chamber systems',#4185,$,$); -#4189=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_06_12','Concrete deep manhole systems',#4185,$,$); -#4190=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_06_14','Concrete manhole systems',#4185,$,$); -#4191=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_06_16','Concrete shallow inspection chamber systems',#4185,$,$); -#4192=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_06_18','Concrete silt trap and flow control chamber systems',#4185,$,$); -#4193=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_06_62','Plastics deep non-entry inspection chamber systems',#4185,$,$); -#4194=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_06_64','Plastics distribution and sampling chamber systems',#4185,$,$); -#4195=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_06_66','Plastics shallow inspection chamber systems',#4185,$,$); -#4196=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_08','Below ground gravity drainage systems',#4174,$,$); -#4197=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_08_15','Combined below-ground drainage pipeline systems',#4196,$,$); -#4198=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_08_16','Combined sewer overflow systems',#4196,$,$); -#4199=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_08_30','Foul waste water below-ground drainage pipeline systems',#4196,$,$); -#4200=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_08_85','Surface water below-ground drainage pipeline systems',#4196,$,$); -#4201=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_10','Below ground pumped drainage systems',#4174,$,$); -#4202=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_10_06','Below-ground private packaged pumping station and pressure pipeline drainage systems',#4201,$,$); -#4203=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_45','Land drainage systems',#4174,$,$); -#4204=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_45_08','Blanket drain land drainage systems',#4203,$,$); -#4205=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_45_20','Culvert land drainage systems',#4203,$,$); -#4206=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_45_30','Filter drain land drainage systems',#4203,$,$); -#4207=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_45_32','Fin drain piped land drainage systems',#4203,$,$); -#4208=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_45_53','Mole or subsoiling drain land drainage systems',#4203,$,$); -#4209=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_45_55','Narrow slot fin drain land drainage systems',#4203,$,$); -#4210=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_45_75','Slitting or grooving land drainage systems',#4203,$,$); -#4211=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_45_85','Subsoil drainage pipe drain systems',#4203,$,$); -#4212=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_45_90','Trenchless drain land drainage systems',#4203,$,$); -#4213=IFCCLASSIFICATIONREFERENCE($,'Ss_50_35','Utility surface and waste water drainage collection systems',#4166,$,$); -#4214=IFCCLASSIFICATIONREFERENCE($,'Ss_50_35_65','Pressure relief drainage systems',#4213,$,$); -#4215=IFCCLASSIFICATIONREFERENCE($,'Ss_50_35_65_08','Blanket drain pressure relief systems',#4214,$,$); -#4216=IFCCLASSIFICATIONREFERENCE($,'Ss_50_35_65_30','Filter drain pressure relief systems',#4214,$,$); -#4217=IFCCLASSIFICATIONREFERENCE($,'Ss_50_35_65_35','Geocomposite sheet fin drain pressure relief systems',#4214,$,$); -#4218=IFCCLASSIFICATIONREFERENCE($,'Ss_50_35_80','Storm water gravity drainage systems',#4213,$,$); -#4219=IFCCLASSIFICATIONREFERENCE($,'Ss_50_35_80_10','Bifurcation storm water overflow systems',#4218,$,$); -#4220=IFCCLASSIFICATIONREFERENCE($,'Ss_50_35_80_72','Rigid attenuation or storage tank for stormwater flood attenuation systems',#4218,$,$); -#4221=IFCCLASSIFICATIONREFERENCE($,'Ss_50_35_82','Surface and waste water gravity drainage systems',#4213,$,$); -#4222=IFCCLASSIFICATIONREFERENCE($,'Ss_50_35_82_41','Inlet drainage systems',#4221,$,$); -#4223=IFCCLASSIFICATIONREFERENCE($,'Ss_50_35_82_59','Outlet drainage systems',#4221,$,$); -#4224=IFCCLASSIFICATIONREFERENCE($,'Ss_50_35_82_73','Road drainage systems',#4221,$,$); -#4225=IFCCLASSIFICATIONREFERENCE($,'Ss_50_35_85','Surface and waste water pumped drainage systems',#4213,$,$); -#4226=IFCCLASSIFICATIONREFERENCE($,'Ss_50_40','Solid waste collection and distribution systems',#4166,$,$); -#4227=IFCCLASSIFICATIONREFERENCE($,'Ss_50_40_95','Waste collection systems',#4226,$,$); -#4228=IFCCLASSIFICATIONREFERENCE($,'Ss_50_40_95_65','Pneumatic waste collection systems',#4227,$,$); -#4229=IFCCLASSIFICATIONREFERENCE($,'Ss_50_50','Gas waste storage, treatment and disposal systems',#4166,$,$); -#4230=IFCCLASSIFICATIONREFERENCE($,'Ss_50_50_45','Landfill gas disposal systems',#4229,$,$); -#4231=IFCCLASSIFICATIONREFERENCE($,'Ss_50_50_95','Waste gas treatment and disposal systems',#4229,$,$); -#4232=IFCCLASSIFICATIONREFERENCE($,'Ss_50_60','Non-aqueous liquid waste storage, treatment and disposal systems',#4166,$,$); -#4233=IFCCLASSIFICATIONREFERENCE($,'Ss_50_60_45','Landfill liquid disposal systems',#4232,$,$); -#4234=IFCCLASSIFICATIONREFERENCE($,'Ss_50_60_90','Waste liquid fuel storage and treatment systems',#4232,$,$); -#4235=IFCCLASSIFICATIONREFERENCE($,'Ss_50_60_95','Waste process liquid storage and treatment systems',#4232,$,$); -#4236=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70','Water waste (drainage) storage, treatment and disposal systems',#4166,$,$); -#4237=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05','Below-ground private drainage disposal systems',#4236,$,$); -#4238=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_20','Below-ground waste water drainage field systems',#4237,$,$); -#4239=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_22','Below-ground drainage packaged grease trap systems',#4237,$,$); -#4240=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_23','Below-ground drainage private packaged septic tank systems',#4237,$,$); -#4241=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_24','Below-ground drainage private packaged sewage treatment systems',#4237,$,$); -#4242=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_25','Below-ground drainage private packaged storage tank systems',#4237,$,$); -#4243=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_79','Below-ground drainage concrete soakaway systems',#4237,$,$); -#4244=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_80','Below-ground drainage granular fill soakaway systems',#4237,$,$); -#4245=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_81','Below-ground drainage modular plastics attenuation or storage tank systems',#4237,$,$); -#4246=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_82','Below-ground drainage modular plastics soakaway systems',#4237,$,$); -#4247=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_83','Below-ground drainage packaged oil and petrol interceptor systems',#4237,$,$); -#4248=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_84','Below-ground drainage packaged silt trap systems',#4237,$,$); -#4249=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_85','Below-ground drainage rigid attenuation or storage tank systems',#4237,$,$); -#4250=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_86','Below-ground drainage wet well systems',#4237,$,$); -#4251=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_95','Below-ground drainage outfall systems',#4237,$,$); -#4252=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_24','Drainage disposal systems',#4236,$,$); -#4253=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_24_80','Soakaway borehole systems',#4252,$,$); -#4254=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_60','Private drainage treatment systems',#4236,$,$); -#4255=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_60_70','Radioactive wastewater treatment systems',#4254,$,$); -#4256=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_83','Surface water tank systems',#4236,$,$); -#4257=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85','Sustainable drainage systems (SuDS)',#4236,$,$); -#4258=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_00','SuDS management train systems',#4257,$,$); -#4259=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_06','Below ground surface water storage tank systems',#4257,$,$); -#4260=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_08','Bioretention area systems',#4257,$,$); -#4261=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_15','Conveyance swale systems',#4257,$,$); -#4262=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_21','Detention basin systems',#4257,$,$); -#4263=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_24','Dry swale systems',#4257,$,$); -#4264=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_30','Filter strip systems',#4257,$,$); -#4265=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_31','Filter drain systems',#4257,$,$); -#4266=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_32','Filtration treatment and separation systems',#4257,$,$); -#4267=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_33','Geocellular attenuation tank systems',#4257,$,$); -#4268=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_34','Geocellular soakaway systems',#4257,$,$); -#4269=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_35','Granular fill soakaway systems',#4257,$,$); -#4270=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_41','Infiltration basin systems',#4257,$,$); -#4271=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_42','Infiltration trench systems',#4257,$,$); -#4272=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_58','Open channel conveyance systems',#4257,$,$); -#4273=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_61','Pervious pavement systems',#4257,$,$); -#4274=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_64','Pond systems',#4257,$,$); -#4275=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_66','Precast concrete soakaway systems',#4257,$,$); -#4276=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_70','Rainwater harvesting systems',#4257,$,$); -#4277=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_75','Sand filter bed systems',#4257,$,$); -#4278=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_76','Sand filter bed surface systems',#4257,$,$); -#4279=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_85','Swale systems',#4257,$,$); -#4280=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_96','Water butt systems',#4257,$,$); -#4281=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_97','Wet swale systems',#4257,$,$); -#4282=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_98','Wetland drainage systems',#4257,$,$); -#4283=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75','Wastewater storage, treatment and disposal systems',#4166,$,$); -#4284=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_01','Aeration systems',#4283,$,$); -#4285=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_01_22','Diffused aeration systems',#4284,$,$); -#4286=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_01_44','Jet aeration systems',#4284,$,$); -#4287=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_01_51','Mechanical aeration systems',#4284,$,$); -#4288=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_01_90','Tray cascade aeration systems',#4284,$,$); -#4289=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_20','Decanting systems',#4283,$,$); -#4290=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_20_96','Wastewater decanting systems',#4289,$,$); -#4291=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_21','Desludging and sludge handling systems',#4283,$,$); -#4292=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_21_20','Desludging systems',#4291,$,$); -#4293=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_21_75','Settlement tank gravity desludging systems',#4291,$,$); -#4294=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_21_80','Sludge handling and treatment systems',#4291,$,$); -#4295=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_34','Grit treatment and removal systems',#4283,$,$); -#4296=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_34_16','Crossflow grit removal systems',#4295,$,$); -#4297=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_34_60','Package grit treatment and removal systems',#4295,$,$); -#4298=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_34_94','Vortex grit removal systems',#4295,$,$); -#4299=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_41','Inlet works systems',#4283,$,$); -#4300=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_41_15','Concrete inlet works systems',#4299,$,$); -#4301=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_41_60','Package inlet works systems',#4299,$,$); -#4302=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_41_66','Prefabricated inlet works systems',#4299,$,$); -#4303=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_58','Odour control systems',#4283,$,$); -#4304=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_58_07','Bio-filtration systems',#4303,$,$); -#4305=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_58_08','Bio-scrubber systems',#4303,$,$); -#4306=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_58_11','Catalytic iron filter systems',#4303,$,$); -#4307=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_58_23','Dry installation systems',#4303,$,$); -#4308=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_58_96','Wet scrubber systems',#4303,$,$); -#4309=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_67','Primary sewage treatment and final settlement systems',#4283,$,$); -#4310=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_67_38','Horizontal flow tank systems',#4309,$,$); -#4311=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_67_46','Lamella tank systems',#4309,$,$); -#4312=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_67_70','Radial flow tank systems',#4309,$,$); -#4313=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_75','Scum removal systems',#4283,$,$); -#4314=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_75_96','Wastewater scum removal systems',#4313,$,$); -#4315=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_77','Secondary sewage treatment systems',#4283,$,$); -#4316=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_77_01','Activated sludge aeration tank systems',#4315,$,$); -#4317=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_77_07','Biological filter tank systems',#4315,$,$); -#4318=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_92','Wastewater chemical dosing systems',#4283,$,$); -#4319=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_92_13','Chemical dosing systems',#4318,$,$); -#4320=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_93','Wastewater filtration systems',#4283,$,$); -#4321=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_93_02','Aggregate filtration systems',#4320,$,$); -#4322=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_93_07','Biological percolating filter tiling systems',#4320,$,$); -#4323=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_93_52','Membrane filtration systems',#4320,$,$); -#4324=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_94','Wastewater screenings handling systems',#4283,$,$); -#4325=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_94_16','Combined screenings capture and handling systems',#4324,$,$); -#4326=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_94_56','Non-powered screening systems',#4324,$,$); -#4327=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_94_64','Powered screenings capture and handling systems',#4324,$,$); -#4328=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_95','Wastewater supply systems',#4283,$,$); -#4329=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_95_67','Pumped wastewater supply systems',#4328,$,$); -#4330=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_98','Wastewater tank systems',#4283,$,$); -#4331=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_98_96','Wastewater tank flushing systems',#4330,$,$); -#4332=IFCCLASSIFICATIONREFERENCE($,'Ss_50_80','Solid waste storage, treatment and disposal systems',#4166,$,$); -#4333=IFCCLASSIFICATIONREFERENCE($,'Ss_50_80_40','Incinerator systems',#4332,$,$); -#4334=IFCCLASSIFICATIONREFERENCE($,'Ss_50_80_80','Solid waste compacting systems',#4332,$,$); -#4335=IFCCLASSIFICATIONREFERENCE($,'Ss_50_80_80_96','Waste compactor systems',#4334,$,$); -#4336=IFCCLASSIFICATIONREFERENCE($,'Ss_50_80_82','Solid waste sorting systems',#4332,$,$); -#4337=IFCCLASSIFICATIONREFERENCE($,'Ss_50_80_96','Weighbridge systems',#4332,$,$); -#4338=IFCCLASSIFICATIONREFERENCE($,'Ss_50_80_96_00','Above ground weighbridge systems',#4337,$,$); -#4339=IFCCLASSIFICATIONREFERENCE($,'Ss_50_80_96_63','Pit weighbridge systems',#4337,$,$); -#4340=IFCCLASSIFICATIONREFERENCE($,'Ss_50_95','Temporary disposal systems',#4166,$,$); -#4341=IFCCLASSIFICATIONREFERENCE($,'Ss_55','Piped supply systems',#2695,$,$); -#4342=IFCCLASSIFICATIONREFERENCE($,'Ss_55_05','Gas extraction, treatment and storage systems',#4341,$,$); -#4343=IFCCLASSIFICATIONREFERENCE($,'Ss_55_05_30','Gas extraction systems',#4342,$,$); -#4344=IFCCLASSIFICATIONREFERENCE($,'Ss_55_05_75','Gas storage tank systems',#4342,$,$); -#4345=IFCCLASSIFICATIONREFERENCE($,'Ss_55_05_85','Gas treatment systems',#4342,$,$); -#4346=IFCCLASSIFICATIONREFERENCE($,'Ss_55_05_95','Gas well systems',#4342,$,$); -#4347=IFCCLASSIFICATIONREFERENCE($,'Ss_55_10','Liquid fuel extraction, treatment and storage systems',#4341,$,$); -#4348=IFCCLASSIFICATIONREFERENCE($,'Ss_55_10_70','Liquid fuel extraction systems',#4347,$,$); -#4349=IFCCLASSIFICATIONREFERENCE($,'Ss_55_10_75','Liquid fuel storage tank systems',#4347,$,$); -#4350=IFCCLASSIFICATIONREFERENCE($,'Ss_55_10_85','Liquid fuel treatment systems',#4347,$,$); -#4351=IFCCLASSIFICATIONREFERENCE($,'Ss_55_10_95','Liquid fuel well systems',#4347,$,$); -#4352=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15','Water extraction, treatment and storage systems',#4341,$,$); -#4353=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_65','Potable water storage tank systems',#4352,$,$); -#4354=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_65_15','Concrete potable water storage systems',#4353,$,$); -#4355=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_65_65','Plastics potable water storage systems',#4353,$,$); -#4356=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_65_72','Reinforced concrete potable water storage systems',#4353,$,$); -#4357=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_65_84','Steel framed potable water storage systems',#4353,$,$); -#4358=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_70','Water reservoir systems',#4352,$,$); -#4359=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_72','Water extraction and monitoring systems',#4352,$,$); -#4360=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_72_20','Water extraction borehole systems',#4359,$,$); -#4361=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_72_50','Water monitoring borehole systems',#4359,$,$); -#4362=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_85','Water treatment and purification systems',#4352,$,$); -#4363=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_85_08','Biological aerated flooded filter systems',#4362,$,$); -#4364=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_85_23','Dissolved air flotation systems',#4362,$,$); -#4365=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_85_46','Lamella plate systems',#4362,$,$); -#4366=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_85_75','Sandfilter systems',#4362,$,$); -#4367=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_85_85','Submerged aerated filter systems',#4362,$,$); -#4368=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_95','Wet well systems',#4352,$,$); -#4369=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_95_64','Piled wet well systems',#4368,$,$); -#4370=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_95_72','Reinforced concrete wet well systems',#4368,$,$); -#4371=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20','Gas distribution and supply systems',#4341,$,$); -#4372=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_15','Compressed air supply systems',#4371,$,$); -#4373=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_15_42','Industrial compressed air supply systems',#4372,$,$); -#4374=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_15_46','Laboratory compressed air supply systems',#4372,$,$); -#4375=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_15_51','Medical compressed air supply systems',#4372,$,$); -#4376=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_33','Gas distribution network systems',#4371,$,$); -#4377=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_33_56','Natural gas distribution network systems',#4376,$,$); -#4378=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_34','Gas supply systems',#4371,$,$); -#4379=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_34_05','Biogas supply systems',#4378,$,$); -#4380=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_34_46','Liquefied petroleum gas (LPG) supply systems',#4378,$,$); -#4381=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_34_57','Natural gas supply systems',#4378,$,$); -#4382=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_34_95','Welding gas supply systems',#4378,$,$); -#4383=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_40','Inert gas supply systems',#4371,$,$); -#4384=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_45','Laboratory gas supply systems',#4371,$,$); -#4385=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_45_05','Laboratory argon supply systems',#4384,$,$); -#4386=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_45_36','Laboratory helium supply systems',#4384,$,$); -#4387=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_45_39','Laboratory hydrogen supply systems',#4384,$,$); -#4388=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_45_56','Laboratory nitrogen supply systems',#4384,$,$); -#4389=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_45_59','Laboratory oxygen supply systems',#4384,$,$); -#4390=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_51','Medical gas supply systems',#4371,$,$); -#4391=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_51_03','Medical anaesthetic gas scavenging systems',#4390,$,$); -#4392=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_51_27','Medical entonox supply systems',#4390,$,$); -#4393=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_51_36','Medical helium/ oxygen mixture supply systems',#4390,$,$); -#4394=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_51_56','Medical nitrous oxide supply systems',#4390,$,$); -#4395=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_51_57','Medical nitrous oxide/ oxygen mixture supply systems',#4390,$,$); -#4396=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_51_59','Medical oxygen supply systems',#4390,$,$); -#4397=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_60','Process gas systems',#4371,$,$); -#4398=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_60_33','Gas vaporizing systems',#4397,$,$); -#4399=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_85','Specialist and high purity gas supply systems',#4371,$,$); -#4400=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_94','Vacuum supply systems',#4371,$,$); -#4401=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_94_51','Medical vacuum supply systems',#4400,$,$); -#4402=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30','Fire extinguishing systems',#4341,$,$); -#4403=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_35','Gaseous and foam fire extinguishing systems',#4402,$,$); -#4404=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_35_10','Carbon dioxide fire extinguishing systems',#4403,$,$); -#4405=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_35_31','Foam fire extinguishing systems',#4403,$,$); -#4406=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_35_35','Halocarbon gas total flooding fire extinguishing systems',#4403,$,$); -#4407=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_35_40','Inert gas total flooding fire extinguishing systems',#4403,$,$); -#4408=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_65','Portable fire extinguishing systems',#4402,$,$); -#4409=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_65_30','Fire blanket systems',#4408,$,$); -#4410=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_65_35','Fire bucket systems',#4408,$,$); -#4411=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_65_65','Portable fire extinguisher systems',#4408,$,$); -#4412=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_96','Water firefighting systems',#4402,$,$); -#4413=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_96_24','Dry dropper systems',#4412,$,$); -#4414=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_96_25','Dry riser systems',#4412,$,$); -#4415=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_96_29','Fire hose reel systems',#4412,$,$); -#4416=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_96_30','Fire hydrant systems',#4412,$,$); -#4417=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_96_95','Water cannon firefighting systems',#4412,$,$); -#4418=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_96_97','Wet riser systems',#4412,$,$); -#4419=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_98','Water fire suppression systems',#4402,$,$); -#4420=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_98_21','Deluge systems',#4419,$,$); -#4421=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_98_23','Domestic sprinkler systems',#4419,$,$); -#4422=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_98_70','Residential water mist systems',#4419,$,$); -#4423=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_98_85','Sprinkler systems',#4419,$,$); -#4424=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_98_96','Water mist systems',#4419,$,$); -#4425=IFCCLASSIFICATIONREFERENCE($,'Ss_55_40','Steam distribution and supply systems',#4341,$,$); -#4426=IFCCLASSIFICATIONREFERENCE($,'Ss_55_40_85','Steam supply and condensate systems',#4425,$,$); -#4427=IFCCLASSIFICATIONREFERENCE($,'Ss_55_40_85_38','Hospital steam supply and condensate systems',#4426,$,$); -#4428=IFCCLASSIFICATIONREFERENCE($,'Ss_55_40_85_41','Industrial steam supply and condensate systems',#4426,$,$); -#4429=IFCCLASSIFICATIONREFERENCE($,'Ss_55_50','Liquid fuel distribution and supply systems',#4341,$,$); -#4430=IFCCLASSIFICATIONREFERENCE($,'Ss_55_50_46','Liquid fuel distribution network systems',#4429,$,$); -#4431=IFCCLASSIFICATIONREFERENCE($,'Ss_55_50_46_58','Oil distribution network systems',#4430,$,$); -#4432=IFCCLASSIFICATIONREFERENCE($,'Ss_55_50_47','Liquid fuel supply systems',#4429,$,$); -#4433=IFCCLASSIFICATIONREFERENCE($,'Ss_55_50_47_10','Biodiesel supply systems',#4432,$,$); -#4434=IFCCLASSIFICATIONREFERENCE($,'Ss_55_50_47_12','Bioethanol supply systems',#4432,$,$); -#4435=IFCCLASSIFICATIONREFERENCE($,'Ss_55_50_47_21','Diesel supply systems',#4432,$,$); -#4436=IFCCLASSIFICATIONREFERENCE($,'Ss_55_50_47_32','Fuel oil supply systems',#4432,$,$); -#4437=IFCCLASSIFICATIONREFERENCE($,'Ss_55_50_47_45','Kerosene/ jet fuel supply systems',#4432,$,$); -#4438=IFCCLASSIFICATIONREFERENCE($,'Ss_55_50_47_46','Liquid biofuel supply systems',#4432,$,$); -#4439=IFCCLASSIFICATIONREFERENCE($,'Ss_55_50_47_61','Petrol supply systems',#4432,$,$); -#4440=IFCCLASSIFICATIONREFERENCE($,'Ss_55_60','Process liquid distribution and supply systems',#4341,$,$); -#4441=IFCCLASSIFICATIONREFERENCE($,'Ss_55_60_45','Liquid acids and bases supply systems',#4440,$,$); -#4442=IFCCLASSIFICATIONREFERENCE($,'Ss_55_60_47','Liquid chemicals supply systems',#4440,$,$); -#4443=IFCCLASSIFICATIONREFERENCE($,'Ss_55_60_50','Liquid polymer supply systems',#4440,$,$); -#4444=IFCCLASSIFICATIONREFERENCE($,'Ss_55_60_55','Lubrication supply systems',#4440,$,$); -#4445=IFCCLASSIFICATIONREFERENCE($,'Ss_55_60_55_70','Rail lubrication supply systems',#4444,$,$); -#4446=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70','Water distribution and supply systems',#4341,$,$); -#4447=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_38','Hot and cold water supply systems',#4446,$,$); -#4448=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_38_15','Cold water supply systems',#4447,$,$); -#4449=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_38_20','Direct hot water storage supply systems',#4447,$,$); -#4450=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_38_40','Incoming water supply systems',#4447,$,$); -#4451=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_38_42','Indirect hot water storage supply systems',#4447,$,$); -#4452=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_38_45','Instantaneous hot water supply systems',#4447,$,$); -#4453=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_38_65','Pumped cold water supply systems',#4447,$,$); -#4454=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_39','Hydroelectric pressure water supply systems',#4446,$,$); -#4455=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_39_10','Buried pressure pipeline systems',#4454,$,$); -#4456=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_42','Irrigation systems',#4446,$,$); -#4457=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_42_20','Drip irrigation systems',#4456,$,$); -#4458=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_42_50','Manual irrigation systems',#4456,$,$); -#4459=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_42_60','Passive irrigation systems',#4456,$,$); -#4460=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_42_85','Sprinkler irrigation systems',#4456,$,$); -#4461=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_42_87','Sub-irrigation systems',#4456,$,$); -#4462=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_94','Washing systems',#4446,$,$); -#4463=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_94_94','Wash plant systems',#4462,$,$); -#4464=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_94_96','Wheel washing systems',#4462,$,$); -#4465=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_95','Water distribution network systems',#4446,$,$); -#4466=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_95_50','Mains water distribution network systems',#4465,$,$); -#4467=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_95_66','Private water distribution network systems',#4465,$,$); -#4468=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_96','Water feature systems',#4446,$,$); -#4469=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_96_15','Cascade and waterfall systems',#4468,$,$); -#4470=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_96_31','Fountain and jet systems',#4468,$,$); -#4471=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_96_83','Self-contained water feature systems',#4468,$,$); -#4472=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_96_96','Water play systems',#4468,$,$); -#4473=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_97','Water reclamation systems',#4446,$,$); -#4474=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_97_35','Grey water reclamation systems',#4473,$,$); -#4475=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_97_70','Rainwater reclamation systems',#4473,$,$); -#4476=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_98','Water treatment systems',#4446,$,$); -#4477=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_98_08','Bore water treatment systems',#4476,$,$); -#4478=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_98_85','Swimming pool water treatment systems',#4476,$,$); -#4479=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_98_92','Ultrapure water treatment systems',#4476,$,$); -#4480=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_99','Water management systems',#4446,$,$); -#4481=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_99_84','Stoplog systems',#4480,$,$); -#4482=IFCCLASSIFICATIONREFERENCE($,'Ss_55_90','Piped solids distribution and supply systems',#4341,$,$); -#4483=IFCCLASSIFICATIONREFERENCE($,'Ss_55_90_65','Piped granule and powder supply systems',#4482,$,$); -#4484=IFCCLASSIFICATIONREFERENCE($,'Ss_55_95','Temporary piped supply systems',#4341,$,$); -#4485=IFCCLASSIFICATIONREFERENCE($,'Ss_60','Heating, cooling and refrigeration systems',#2695,$,$); -#4486=IFCCLASSIFICATIONREFERENCE($,'Ss_60_30','Rail and paving heating systems',#4485,$,$); -#4487=IFCCLASSIFICATIONREFERENCE($,'Ss_60_30_60','Pavement heating systems',#4486,$,$); -#4488=IFCCLASSIFICATIONREFERENCE($,'Ss_60_30_60_27','Electric pavement heating systems',#4487,$,$); -#4489=IFCCLASSIFICATIONREFERENCE($,'Ss_60_30_70','Railway heating systems',#4486,$,$); -#4490=IFCCLASSIFICATIONREFERENCE($,'Ss_60_30_70_65','Points heating systems',#4489,$,$); -#4491=IFCCLASSIFICATIONREFERENCE($,'Ss_60_30_75','Runway heating systems',#4486,$,$); -#4492=IFCCLASSIFICATIONREFERENCE($,'Ss_60_30_90','Tramway heating systems',#4486,$,$); -#4493=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40','Space heating and cooling systems',#4485,$,$); -#4494=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_13','Climatic ceiling and beam systems',#4493,$,$); -#4495=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_13_13','Climatic beam systems',#4494,$,$); -#4496=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_13_14','Climatic ceiling systems',#4494,$,$); -#4497=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_15','Combined heating, cooling and power systems',#4493,$,$); -#4498=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_15_40','Combined heat and power systems',#4497,$,$); -#4499=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_15_90','Combined underfloor heating and cooling systems',#4497,$,$); -#4500=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_17','Cooling systems',#4493,$,$); -#4501=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_17_12','Chilled water systems',#4500,$,$); -#4502=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_17_21','District cooling systems',#4500,$,$); -#4503=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_17_71','Refrigerant cooling systems',#4500,$,$); -#4504=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_17_92','Underfloor chilled water systems',#4500,$,$); -#4505=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_17_94','Variable refrigerant flow systems',#4500,$,$); -#4506=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_17_96','Water cooling systems',#4500,$,$); -#4507=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_36','Heat pump systems',#4493,$,$); -#4508=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_36_05','Air source heat pump systems',#4507,$,$); -#4509=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_36_35','Ground source heat pump systems',#4507,$,$); -#4510=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_36_96','Water source heat pump systems',#4507,$,$); -#4511=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_37','Heating systems',#4493,$,$); -#4512=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_37_21','Direct gas fired heating systems',#4511,$,$); -#4513=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_37_22','District heating systems',#4511,$,$); -#4514=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_37_26','Electric heating systems',#4511,$,$); -#4515=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_37_27','Electric underfloor heating systems',#4511,$,$); -#4516=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_37_28','Electrical resistance trace heating systems',#4511,$,$); -#4517=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_37_48','Low temperature hot water heating systems',#4511,$,$); -#4518=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_37_51','Medium temperature hot water heating systems',#4511,$,$); -#4519=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_37_81','Solar heating systems',#4511,$,$); -#4520=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_37_85','Steam heating systems',#4511,$,$); -#4521=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_37_94','Underfloor low temperature hot water heating systems',#4511,$,$); -#4522=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_84','Space heating and cooling distribution network systems',#4493,$,$); -#4523=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_84_21','District cooling distribution network systems',#4522,$,$); -#4524=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_84_22','District heating distribution network systems',#4522,$,$); -#4525=IFCCLASSIFICATIONREFERENCE($,'Ss_60_60','Refrigeration systems',#4485,$,$); -#4526=IFCCLASSIFICATIONREFERENCE($,'Ss_60_60_15','Cold room systems',#4525,$,$); -#4527=IFCCLASSIFICATIONREFERENCE($,'Ss_60_60_15_10','Catering cold room systems',#4526,$,$); -#4528=IFCCLASSIFICATIONREFERENCE($,'Ss_60_60_15_50','Mortuary cold room systems',#4526,$,$); -#4529=IFCCLASSIFICATIONREFERENCE($,'Ss_60_60_17','Cold storage systems',#4525,$,$); -#4530=IFCCLASSIFICATIONREFERENCE($,'Ss_60_60_70','Refrigerant systems',#4525,$,$); -#4531=IFCCLASSIFICATIONREFERENCE($,'Ss_60_60_70_15','Refrigerant charging systems',#4530,$,$); -#4532=IFCCLASSIFICATIONREFERENCE($,'Ss_60_60_70_70','Refrigerant recovery systems',#4530,$,$); -#4533=IFCCLASSIFICATIONREFERENCE($,'Ss_60_80','Drying systems',#4485,$,$); -#4534=IFCCLASSIFICATIONREFERENCE($,'Ss_60_80_08','Bottle and can drying systems',#4533,$,$); -#4535=IFCCLASSIFICATIONREFERENCE($,'Ss_60_95','Temporary heating, cooling and refrigeration systems',#4485,$,$); -#4536=IFCCLASSIFICATIONREFERENCE($,'Ss_65','Ventilation and air conditioning systems',#2695,$,$); -#4537=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40','Ventilation systems',#4536,$,$); -#4538=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_25','Dust extract systems',#4537,$,$); -#4539=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_32','Fume extract systems',#4537,$,$); -#4540=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_32_32','Fume cupboard extract systems',#4539,$,$); -#4541=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_32_70','Recirculatory fume cupboard systems',#4539,$,$); -#4542=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_32_75','Safety cabinet extract systems',#4539,$,$); -#4543=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_33','General space ventilation systems',#4537,$,$); -#4544=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_33_45','Kitchen extract ventilation systems',#4543,$,$); -#4545=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_33_48','Local extract ventilation systems',#4543,$,$); -#4546=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_33_50','Mechanical extract ventilation systems',#4543,$,$); -#4547=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_33_51','Mechanical supply ventilation systems',#4543,$,$); -#4548=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_33_52','Mechanical and whole building ventilation systems',#4543,$,$); -#4549=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_33_56','Natural ventilation systems',#4543,$,$); -#4550=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_33_60','Passive stack ventilation systems',#4543,$,$); -#4551=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_33_90','Toilet extract ventilation systems',#4543,$,$); -#4552=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_42','Industrial fume extract systems',#4537,$,$); -#4553=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_42_45','Local exhaust ventilation systems',#4552,$,$); -#4554=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_42_95','Vehicle exhaust extract systems',#4552,$,$); -#4555=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_55','Nuclear ventilation systems',#4537,$,$); -#4556=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_55_22','Decontamination areas ventilation systems',#4555,$,$); -#4557=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_80','Smoke extract and control systems',#4537,$,$); -#4558=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_80_65','Pressure differential systems',#4557,$,$); -#4559=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_80_80','Smoke and heat exhaust ventilation systems',#4557,$,$); -#4560=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_94','Vehicular space ventilation systems',#4537,$,$); -#4561=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_94_10','Car park extract systems',#4560,$,$); -#4562=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_94_11','Car park supply systems',#4560,$,$); -#4563=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_94_90','Tunnel ventilation systems',#4560,$,$); -#4564=IFCCLASSIFICATIONREFERENCE($,'Ss_65_60','Specialist ventilation systems',#4536,$,$); -#4565=IFCCLASSIFICATIONREFERENCE($,'Ss_65_60_95','Wind tunnel systems',#4564,$,$); -#4566=IFCCLASSIFICATIONREFERENCE($,'Ss_65_80','Air conditioning systems',#4536,$,$); -#4567=IFCCLASSIFICATIONREFERENCE($,'Ss_65_80_05','Central air conditioning systems',#4566,$,$); -#4568=IFCCLASSIFICATIONREFERENCE($,'Ss_65_80_05_10','Centralized all-air conditioning systems',#4567,$,$); -#4569=IFCCLASSIFICATIONREFERENCE($,'Ss_65_80_05_30','Fan coil unit air conditioning systems',#4567,$,$); -#4570=IFCCLASSIFICATIONREFERENCE($,'Ss_65_80_05_40','Induction unit air conditioning systems',#4567,$,$); -#4571=IFCCLASSIFICATIONREFERENCE($,'Ss_65_80_15','Controlled environment systems',#4566,$,$); -#4572=IFCCLASSIFICATIONREFERENCE($,'Ss_65_80_45','Local air conditioning systems',#4566,$,$); -#4573=IFCCLASSIFICATIONREFERENCE($,'Ss_65_80_45_25','Evaporative cooling systems',#4572,$,$); -#4574=IFCCLASSIFICATIONREFERENCE($,'Ss_65_80_45_48','Local underfloor air conditioning systems',#4572,$,$); -#4575=IFCCLASSIFICATIONREFERENCE($,'Ss_65_80_45_72','Room air conditioning systems',#4572,$,$); -#4576=IFCCLASSIFICATIONREFERENCE($,'Ss_65_95','Temporary ventilation and air conditioning systems',#4536,$,$); -#4577=IFCCLASSIFICATIONREFERENCE($,'Ss_70','Electrical systems',#2695,$,$); -#4578=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10','Electrical power generation and transmission systems',#4577,$,$); -#4579=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_30','Fossil fuel power generation systems',#4578,$,$); -#4580=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_30_33','Gas power generating systems',#4579,$,$); -#4581=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_30_70','Reciprocating internal combustion engine',#4579,$,$); -#4582=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_30_72','Reciprocating internal combustion engine driven alternating current generator systems',#4579,$,$); -#4583=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_35','High voltage transmission systems',#4578,$,$); -#4584=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_70','Renewable power generation systems',#4578,$,$); -#4585=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_70_33','Geothermal power generation systems',#4584,$,$); -#4586=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_70_35','Grid-connected photovoltaic systems',#4584,$,$); -#4587=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_70_36','Hydroelectric power generation systems',#4584,$,$); -#4588=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_70_80','Small-scale wave and tidal power generation systems',#4584,$,$); -#4589=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_70_82','Small-scale wind power generation systems',#4584,$,$); -#4590=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_70_85','Stand-alone photovoltaic systems',#4584,$,$); -#4591=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_70_95','Water mill systems',#4584,$,$); -#4592=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_70_97','Water turbine systems',#4584,$,$); -#4593=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_70_98','Wind power generating systems',#4584,$,$); -#4594=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30','Electricity distribution systems',#4577,$,$); -#4595=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_25','Protection systems',#4594,$,$); -#4596=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_25_25','Earthing and bonding systems',#4595,$,$); -#4597=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_35','High voltage systems',#4594,$,$); -#4598=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_35_30','High voltage site connection systems',#4597,$,$); -#4599=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_35_35','High voltage distribution systems',#4597,$,$); -#4600=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_45','Low voltage systems',#4594,$,$); -#4601=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_45_40','Low voltage site connection systems',#4600,$,$); -#4602=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_45_45','Low voltage distribution systems',#4600,$,$); -#4603=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_45_92','Uninterruptible power supply systems',#4600,$,$); -#4604=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_60','Overhead line traction power distribution systems',#4594,$,$); -#4605=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_60_11','Catenary overhead line systems',#4604,$,$); -#4606=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_60_89','Trolley wire overhead line systems',#4604,$,$); -#4607=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_80','Small power systems',#4594,$,$); -#4608=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_80_35','Hard-wired voltage small power systems',#4607,$,$); -#4609=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_80_45','Low voltage small power systems with prefabricated wiring',#4607,$,$); -#4610=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_90','Conductor rail traction power distribution systems',#4594,$,$); -#4611=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_90_15','Conductor rail electrification systems',#4610,$,$); -#4612=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_90_90','Third rail electrification systems',#4610,$,$); -#4613=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_94','Vehicle charging systems',#4594,$,$); -#4614=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_94_27','Electric vehicle charging systems',#4613,$,$); -#4615=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80','Lighting systems',#4577,$,$); -#4616=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_01','Aeronautical lighting systems',#4615,$,$); -#4617=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_01_02','Approach lighting systems',#4616,$,$); -#4618=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_01_03','Apron lighting systems',#4616,$,$); -#4619=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_01_47','Lighting beacon systems',#4616,$,$); -#4620=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_01_65','Precision approach path indicator systems',#4616,$,$); -#4621=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_01_74','Runway lighting systems',#4616,$,$); -#4622=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_01_87','Taxiway lighting systems',#4616,$,$); -#4623=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_25','External lighting systems',#4615,$,$); -#4624=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_25_05','Amenity lighting systems',#4623,$,$); -#4625=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_25_70','Roadway lighting systems',#4623,$,$); -#4626=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_25_90','Tunnel lighting systems',#4623,$,$); -#4627=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_33','General space lighting systems',#4615,$,$); -#4628=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_33_12','Central battery supplied emergency lighting systems',#4627,$,$); -#4629=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_33_30','Fibre optic lighting systems',#4627,$,$); -#4630=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_33_33','General lighting systems with prefabricated wiring',#4627,$,$); -#4631=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_33_35','Hard-wired general lighting systems',#4627,$,$); -#4632=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_33_88','Theatrical/ stage lighting systems',#4627,$,$); -#4633=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_33_92','Underwater lighting systems',#4627,$,$); -#4634=IFCCLASSIFICATIONREFERENCE($,'Ss_70_95','Temporary electrical systems',#4577,$,$); -#4635=IFCCLASSIFICATIONREFERENCE($,'Ss_75','Communications, security, safety, control and protection systems',#2695,$,$); -#4636=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10','Communications systems',#4635,$,$); -#4637=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_21','Data distribution and telecommunications systems',#4636,$,$); -#4638=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_21_21','Data distribution systems',#4637,$,$); -#4639=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_21_48','Local area network (LAN) systems',#4637,$,$); -#4640=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_21_52','Mobile telecommunications systems',#4637,$,$); -#4641=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_21_88','Telecommunications systems',#4637,$,$); -#4642=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_21_97','Wide area network (WAN) systems',#4637,$,$); -#4643=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_46','Listening systems',#4636,$,$); -#4644=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_46_05','Audio-frequency induction-loop systems',#4643,$,$); -#4645=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_46_42','Infrared listening systems',#4643,$,$); -#4646=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_68','Public communications systems',#4636,$,$); -#4647=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_68_02','Advertising display systems',#4646,$,$); -#4648=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_68_07','Bell communication systems',#4646,$,$); -#4649=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_68_13','Clock systems',#4646,$,$); -#4650=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_68_42','Information display systems',#4646,$,$); -#4651=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_68_68','Public address systems',#4646,$,$); -#4652=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_68_69','Queue management systems',#4646,$,$); -#4653=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_70','Radio and television distribution systems',#4636,$,$); -#4654=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_70_70','Radio distribution systems',#4653,$,$); -#4655=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_70_88','Television distribution systems',#4653,$,$); -#4656=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_72','Emergency communication systems',#4636,$,$); -#4657=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_72_30','Firefighting intercom systems',#4656,$,$); -#4658=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_72_70','Radio communications systems',#4656,$,$); -#4659=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_72_72','Roadway emergency communication systems',#4656,$,$); -#4660=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_88','Timing and scoring systems',#4636,$,$); -#4661=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_88_05','Athletics timing and scoring systems',#4660,$,$); -#4662=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_88_86','Swimming pool timing and scoring systems',#4660,$,$); -#4663=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30','Signal systems',#4635,$,$); -#4664=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_35','Highway signal and control systems',#4663,$,$); -#4665=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_35_52','Motorway signal and control systems',#4664,$,$); -#4666=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_35_72','Road signal and control systems',#4664,$,$); -#4667=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_50','Marine signal systems',#4663,$,$); -#4668=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_60','Obstacle beacon systems',#4663,$,$); -#4669=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_70','Railway signal and control systems',#4663,$,$); -#4670=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_70_02','Automatic train operation (ATO) systems',#4669,$,$); -#4671=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_70_03','Automatic train protection (ATP) systems',#4669,$,$); -#4672=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_70_05','Automatic warning systems (AWS)',#4669,$,$); -#4673=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_70_15','Communications based train control (CBTC) systems',#4669,$,$); -#4674=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_70_27','Emergency traction current discharge systems (ETCDS)',#4669,$,$); -#4675=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_70_30','Fixed block signalling systems',#4669,$,$); -#4676=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_70_53','Moving block signalling systems',#4669,$,$); -#4677=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_70_70','Rail signal systems',#4669,$,$); -#4678=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_70_90','Train protection warning systems (TPWS)',#4669,$,$); -#4679=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_90','Tramway signal systems',#4663,$,$); -#4680=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_97','Waterway signal systems',#4663,$,$); -#4681=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_98','Wind direction indication systems',#4663,$,$); -#4682=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_98_96','Windsock systems',#4681,$,$); -#4683=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40','Security systems',#4635,$,$); -#4684=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_02','Access control systems',#4683,$,$); -#4685=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_02_05','Audio intercom systems',#4684,$,$); -#4686=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_02_11','Card access control systems',#4684,$,$); -#4687=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_02_94','Video intercom systems',#4684,$,$); -#4688=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_53','Monitoring systems',#4683,$,$); -#4689=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_53_86','Surveillance CCTV systems',#4688,$,$); -#4690=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_53_90','Train dispatch CCTV systems',#4688,$,$); -#4691=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_53_95','Voice recording systems',#4688,$,$); -#4692=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_73','Security screening systems',#4683,$,$); -#4693=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_73_11','Cabin baggage screening systems',#4692,$,$); -#4694=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_73_60','Passenger screening systems',#4692,$,$); -#4695=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_75','Security detection alarm systems',#4683,$,$); -#4696=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_75_02','Aerospace security detection and warning systems',#4695,$,$); -#4697=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_75_40','Intruder detection and alarm systems',#4695,$,$); -#4698=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_75_50','Marine and waterway security detection and warning systems',#4695,$,$); -#4699=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50','Safety and protection systems',#4635,$,$); -#4700=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_11','Call and alarm systems',#4699,$,$); -#4701=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_11_05','Assistance call systems',#4700,$,$); -#4702=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_11_27','Emergency voice communication systems',#4700,$,$); -#4703=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_11_57','Nurse call systems',#4700,$,$); -#4704=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_11_95','Voice alarm systems',#4700,$,$); -#4705=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_15','Cathodic protection systems',#4699,$,$); -#4706=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_15_02','Adhesive backed zinc sheet anode systems',#4705,$,$); -#4707=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_15_09','Buried galvanic anode systems',#4705,$,$); -#4708=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_15_10','Buried impressed current anode systems',#4705,$,$); -#4709=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_15_27','Embedded impressed current anode systems',#4705,$,$); -#4710=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_15_28','Embedded zinc anode systems',#4705,$,$); -#4711=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_15_41','Immersed galvanic anode systems',#4705,$,$); -#4712=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_15_42','Immersed impressed current anode systems',#4705,$,$); -#4713=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_15_72','Recess mounted impressed current anode systems',#4705,$,$); -#4714=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_15_85','Surface mounted impressed current anode systems',#4705,$,$); -#4715=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_15_99','Zinc mesh in overlay systems',#4705,$,$); -#4716=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_26','Debris detection systems',#4699,$,$); -#4717=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_26_30','Foreign object debris (FOD) detection systems',#4716,$,$); -#4718=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_28','Detection and alarm systems',#4699,$,$); -#4719=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_28_05','Aspirating detection systems',#4718,$,$); -#4720=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_28_22','Domestic premises fire detection and alarm systems',#4718,$,$); -#4721=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_28_24','Duct smoke detector systems',#4718,$,$); -#4722=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_28_29','Fire detection and alarm systems',#4718,$,$); -#4723=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_28_30','Fixed gas detection and alarm systems',#4718,$,$); -#4724=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_28_32','Flow sample gas detection and alarm systems',#4718,$,$); -#4725=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_28_71','Refrigerant leak detection and alarm systems',#4718,$,$); -#4726=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_28_96','Water leak detection and alarm systems',#4718,$,$); -#4727=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_28_97','Water presence detection and alarm systems',#4718,$,$); -#4728=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_35','Healthcare imaging systems',#4699,$,$); -#4729=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_45','Electrical protection systems',#4699,$,$); -#4730=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_45_45','Lightning protection systems',#4729,$,$); -#4731=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_60','Patient monitoring and telemetry systems',#4699,$,$); -#4732=IFCCLASSIFICATIONREFERENCE($,'Ss_75_60','Environmental safety systems',#4635,$,$); -#4733=IFCCLASSIFICATIONREFERENCE($,'Ss_75_60_25','Earthquake warning systems',#4732,$,$); -#4734=IFCCLASSIFICATIONREFERENCE($,'Ss_75_60_30','Flood warning systems',#4732,$,$); -#4735=IFCCLASSIFICATIONREFERENCE($,'Ss_75_60_50','Meteorological detection and warning systems',#4732,$,$); -#4736=IFCCLASSIFICATIONREFERENCE($,'Ss_75_60_52','Meteorological instrumentation systems',#4732,$,$); -#4737=IFCCLASSIFICATIONREFERENCE($,'Ss_75_60_52_95','Weather observation systems',#4736,$,$); -#4738=IFCCLASSIFICATIONREFERENCE($,'Ss_75_60_70','Radiation detection and alarm systems',#4732,$,$); -#4739=IFCCLASSIFICATIONREFERENCE($,'Ss_75_60_75','Seismic instrumentation systems',#4732,$,$); -#4740=IFCCLASSIFICATIONREFERENCE($,'Ss_75_60_90','Tsunami warning systems',#4732,$,$); -#4741=IFCCLASSIFICATIONREFERENCE($,'Ss_75_60_95','Volcanic eruption warning systems',#4732,$,$); -#4742=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70','Control and management systems',#4635,$,$); -#4743=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_05','Airport control systems',#4742,$,$); -#4744=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_05_04','Automatic aircraft docking systems',#4743,$,$); -#4745=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_10','Bridge control systems',#4742,$,$); -#4746=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_20','Dam control systems',#4742,$,$); -#4747=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_35','Highway control systems',#4742,$,$); -#4748=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_50','Marine control systems',#4742,$,$); -#4749=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52','Mechanical engineering services control and management systems',#4742,$,$); -#4750=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_03','Air to air heat pump control systems',#4749,$,$); -#4751=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_14','Climatic ceiling panels and beams control systems',#4749,$,$); -#4752=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_15','Combined heat and power control systems',#4749,$,$); -#4753=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_16','Constant volume air conditioning control systems',#4749,$,$); -#4754=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_17','Cooling system control systems',#4749,$,$); -#4755=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_23','Domestic heating system control systems',#4749,$,$); -#4756=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_28','Extract ventilation control systems',#4749,$,$); -#4757=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_29','Fan coil unit air conditioning control systems',#4749,$,$); -#4758=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_32','Fuel supply control systems',#4749,$,$); -#4759=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_33','Gas fired heating control systems',#4749,$,$); -#4760=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_36','Heating system control systems',#4749,$,$); -#4761=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_38','Heat pump control systems',#4749,$,$); -#4762=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_52','Mixed mode ventilation control systems',#4749,$,$); -#4763=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_56','Natural ventilation control systems',#4749,$,$); -#4764=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_70','Radiant heating control systems',#4749,$,$); -#4765=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_80','Smoke and heat detection extract control systems',#4749,$,$); -#4766=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_81','Smoke and heat detection shut down control systems',#4749,$,$); -#4767=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_85','Steam and condensate control systems',#4749,$,$); -#4768=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_93','Variable volume air conditioning control systems',#4749,$,$); -#4769=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_94','Ventilation control systems',#4749,$,$); -#4770=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_96','Water supply control systems',#4749,$,$); -#4771=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_97','Water to air heat pump control systems',#4749,$,$); -#4772=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_54','Metering, monitoring and management systems',#4742,$,$); -#4773=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_54_03','Active water monitoring systems',#4772,$,$); -#4774=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_54_10','Building monitoring and management systems',#4772,$,$); -#4775=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_54_15','Communications monitoring and management systems',#4772,$,$); -#4776=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_54_25','Electricity metering systems',#4772,$,$); -#4777=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_54_30','Fuel metering systems',#4772,$,$); -#4778=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_54_60','Passive water monitoring systems',#4772,$,$); -#4779=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_54_95','Water metering systems',#4772,$,$); -#4780=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_72','Road control systems',#4742,$,$); -#4781=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85','Structural monitoring systems',#4742,$,$); -#4782=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85_18','Crack gauge monitoring systems',#4781,$,$); -#4783=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85_27','Electrolevel monitoring systems',#4781,$,$); -#4784=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85_30','Fibre optic monitoring systems',#4781,$,$); -#4785=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85_47','Liquid levelling monitoring systems',#4781,$,$); -#4786=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85_48','Load cell monitoring systems',#4781,$,$); -#4787=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85_62','Piezometer monitoring systems',#4781,$,$); -#4788=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85_66','Precise levelling monitoring systems',#4781,$,$); -#4789=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85_67','Prism monitoring systems',#4781,$,$); -#4790=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85_84','Strain gauge monitoring systems',#4781,$,$); -#4791=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85_86','Sub-surface monitoring array systems',#4781,$,$); -#4792=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85_87','Tape extensometer monitoring systems',#4781,$,$); -#4793=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85_90','Tilt sensor monitoring systems',#4781,$,$); -#4794=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85_92','Total station monitoring systems',#4781,$,$); -#4795=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_90','Traffic monitoring systems',#4742,$,$); -#4796=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_90_90','Traffic enforcement camera systems',#4795,$,$); -#4797=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_96','Water supply and wastewater control systems',#4742,$,$); -#4798=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_96_21','Desludging control systems',#4797,$,$); -#4799=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_96_30','Flow measurement and control systems',#4797,$,$); -#4800=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_96_96','Wastewater supply control systems',#4797,$,$); -#4801=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_96_98','Water supply quality control systems',#4797,$,$); -#4802=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_97','Waterway control systems',#4742,$,$); -#4803=IFCCLASSIFICATIONREFERENCE($,'Ss_75_90','Ticket management systems',#4635,$,$); -#4804=IFCCLASSIFICATIONREFERENCE($,'Ss_75_90_80','Ticketing systems',#4803,$,$); -#4805=IFCCLASSIFICATIONREFERENCE($,'Ss_75_90_93','Ticket validation systems',#4803,$,$); -#4806=IFCCLASSIFICATIONREFERENCE($,'Ss_75_90_93_11','Card reading systems',#4805,$,$); -#4807=IFCCLASSIFICATIONREFERENCE($,'Ss_75_90_93_60','Passenger check-in systems',#4805,$,$); -#4808=IFCCLASSIFICATIONREFERENCE($,'Ss_75_90_93_88','Ticket reading systems',#4805,$,$); -#4809=IFCCLASSIFICATIONREFERENCE($,'Ss_75_95','Temporary communications, security, safety, control and protection systems',#4635,$,$); -#4810=IFCCLASSIFICATIONREFERENCE($,'Ss_80','Transport systems',#2695,$,$); -#4811=IFCCLASSIFICATIONREFERENCE($,'Ss_80_10','Cable transport systems',#4810,$,$); -#4812=IFCCLASSIFICATIONREFERENCE($,'Ss_80_10_05','Aerial tram systems',#4811,$,$); -#4813=IFCCLASSIFICATIONREFERENCE($,'Ss_80_10_10','Cable car systems',#4811,$,$); -#4814=IFCCLASSIFICATIONREFERENCE($,'Ss_80_10_15','Chairlift systems',#4811,$,$); -#4815=IFCCLASSIFICATIONREFERENCE($,'Ss_80_10_30','Funicular systems',#4811,$,$); -#4816=IFCCLASSIFICATIONREFERENCE($,'Ss_80_10_35','Gondola systems',#4811,$,$); -#4817=IFCCLASSIFICATIONREFERENCE($,'Ss_80_10_70','Ropeway tow systems',#4811,$,$); -#4818=IFCCLASSIFICATIONREFERENCE($,'Ss_80_10_85','Surface lift systems',#4811,$,$); -#4819=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20','Conveying systems',#4810,$,$); -#4820=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_05','Automatic guided vehicle systems',#4819,$,$); -#4821=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_06','Baggage handling systems',#4819,$,$); -#4822=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_06_04','Airport baggage handling systems',#4821,$,$); -#4823=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_10','Bulk material conveying systems',#4819,$,$); -#4824=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_11','Cargo handling systems',#4819,$,$); -#4825=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_23','Document conveying systems',#4819,$,$); -#4826=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_23_65','Pneumatic document conveying systems',#4825,$,$); -#4827=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_60','Parcel sorting systems',#4819,$,$); -#4828=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_62','People conveying systems',#4819,$,$); -#4829=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_62_28','Escalator systems',#4828,$,$); -#4830=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_62_53','Moving walkway systems',#4828,$,$); -#4831=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_63','Piece conveying systems',#4819,$,$); -#4832=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_63_59','Overhead piece conveying systems',#4831,$,$); -#4833=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_65','Pneumatic conveying systems',#4819,$,$); -#4834=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30','Crane and hoist systems',#4810,$,$); -#4835=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_15','Crane systems',#4834,$,$); -#4836=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_15_10','Bulk handling crane systems',#4835,$,$); -#4837=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_15_15','Container handling crane systems',#4835,$,$); -#4838=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_15_59','Overhead crane systems',#4835,$,$); -#4839=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_20','Derrick systems',#4834,$,$); -#4840=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_25','Dynamic permanent access and safety equipment systems',#4834,$,$); -#4841=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_25_30','Fixed rig suspended access systems',#4840,$,$); -#4842=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_25_32','Gantry access systems',#4840,$,$); -#4843=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_25_35','Guided type fall arrest systems',#4840,$,$); -#4844=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_25_50','Mobile rig monorail suspended access systems',#4840,$,$); -#4845=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_25_52','Mobile rig tracked suspended access systems',#4840,$,$); -#4846=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_25_55','Mobile rig trackless suspended access systems',#4840,$,$); -#4847=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_25_75','Robotic cleaning systems',#4840,$,$); -#4848=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_25_80','Single point anchorage fall arrest systems',#4840,$,$); -#4849=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_25_90','Travelling ladder access systems',#4840,$,$); -#4850=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_40','Hoist systems',#4834,$,$); -#4851=IFCCLASSIFICATIONREFERENCE($,'Ss_80_50','Lift systems',#4810,$,$); -#4852=IFCCLASSIFICATIONREFERENCE($,'Ss_80_50_60','Passenger and goods lift systems',#4851,$,$); -#4853=IFCCLASSIFICATIONREFERENCE($,'Ss_80_50_60_26','Electric lift systems',#4852,$,$); -#4854=IFCCLASSIFICATIONREFERENCE($,'Ss_80_50_60_39','Hydraulic lift systems',#4852,$,$); -#4855=IFCCLASSIFICATIONREFERENCE($,'Ss_80_50_60_50','Manual dumbwaiter systems',#4852,$,$); -#4856=IFCCLASSIFICATIONREFERENCE($,'Ss_80_50_60_60','Paternoster systems',#4852,$,$); -#4857=IFCCLASSIFICATIONREFERENCE($,'Ss_80_50_60_65','Powered homelift systems',#4852,$,$); -#4858=IFCCLASSIFICATIONREFERENCE($,'Ss_80_50_60_83','Stairlift systems',#4852,$,$); -#4859=IFCCLASSIFICATIONREFERENCE($,'Ss_80_50_60_85','Step lift systems',#4852,$,$); -#4860=IFCCLASSIFICATIONREFERENCE($,'Ss_80_50_60_94','Vertical platform lift systems',#4852,$,$); -#4861=IFCCLASSIFICATIONREFERENCE($,'Ss_80_50_94','Vehicle and boat stacking systems',#4851,$,$); -#4862=IFCCLASSIFICATIONREFERENCE($,'Ss_80_50_96','Warehouse stacking systems',#4851,$,$); -#4863=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70','Track systems',#4810,$,$); -#4864=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70_46','Level crossing systems',#4863,$,$); -#4865=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70_46_60','Pedestrian level crossing systems',#4864,$,$); -#4866=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70_46_93','User worked level crossing systems',#4864,$,$); -#4867=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70_46_95','Vehicular level crossing systems',#4864,$,$); -#4868=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70_50','Monorail systems',#4863,$,$); -#4869=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70_70','Rail track systems',#4863,$,$); -#4870=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70_70_06','Ballasted rail track systems',#4869,$,$); -#4871=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70_70_27','Embedded rail systems',#4869,$,$); -#4872=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70_70_56','Non-embedded slab track rail systems',#4869,$,$); -#4873=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70_70_65','Precast track bed systems',#4869,$,$); -#4874=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70_89','Train arrestor systems',#4863,$,$); -#4875=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70_89_30','Fixed train arrestor systems',#4874,$,$); -#4876=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70_89_50','Moveable train arrestor systems',#4874,$,$); -#4877=IFCCLASSIFICATIONREFERENCE($,'Ss_80_80','Turntable systems',#4810,$,$); -#4878=IFCCLASSIFICATIONREFERENCE($,'Ss_80_80_20','Display turntable systems',#4877,$,$); -#4879=IFCCLASSIFICATIONREFERENCE($,'Ss_80_80_30','Floor turntable systems',#4877,$,$); -#4880=IFCCLASSIFICATIONREFERENCE($,'Ss_80_80_40','Industrial turntable systems',#4877,$,$); -#4881=IFCCLASSIFICATIONREFERENCE($,'Ss_80_80_70','Railway turntable systems',#4877,$,$); -#4882=IFCCLASSIFICATIONREFERENCE($,'Ss_80_80_85','Stage turntable systems',#4877,$,$); -#4883=IFCCLASSIFICATIONREFERENCE($,'Ss_80_90','Vehicle access systems',#4810,$,$); -#4884=IFCCLASSIFICATIONREFERENCE($,'Ss_80_90_05','Aircraft passenger loading bridge systems',#4883,$,$); -#4885=IFCCLASSIFICATIONREFERENCE($,'Ss_80_90_05_60','Passenger loading bridge systems',#4884,$,$); -#4886=IFCCLASSIFICATIONREFERENCE($,'Ss_80_90_70','Rocket passenger access systems',#4883,$,$); -#4887=IFCCLASSIFICATIONREFERENCE($,'Ss_80_90_75','Ship passenger loading bridge systems',#4883,$,$); -#4888=IFCCLASSIFICATIONREFERENCE($,'Ss_80_95','Temporary transport systems',#4810,$,$); -#4889=IFCCLASSIFICATIONREFERENCE($,'Ss_85','Process engineering systems',#2695,$,$); -#4890=IFCCLASSIFICATIONREFERENCE($,'Ss_85_72','Robotic systems',#4889,$,$); -#4891=IFCCLASSIFICATIONREFERENCE($,'Ss_85_95','Temporary process engineering systems',#4889,$,$); -#4892=IFCCLASSIFICATIONREFERENCE($,'Ss_90','Soft facility management systems',#2695,$,$); -#4893=IFCCLASSIFICATIONREFERENCE($,'Ss_90_05','Demand for space',#4892,$,$); -#4894=IFCCLASSIFICATIONREFERENCE($,'Ss_90_06','Demand for technical infrastructure',#4892,$,$); -#4895=IFCCLASSIFICATIONREFERENCE($,'Ss_90_07','Demand for cleaning',#4892,$,$); -#4896=IFCCLASSIFICATIONREFERENCE($,'Ss_90_08','Demand related to outdoor space',#4892,$,$); -#4897=IFCCLASSIFICATIONREFERENCE($,'Ss_90_09','Workplace',#4892,$,$); -#4898=IFCCLASSIFICATIONREFERENCE($,'Ss_90_10','Specific demand related to space and infrastructure',#4892,$,$); -#4899=IFCCLASSIFICATIONREFERENCE($,'Ss_90_11','Demand for health, safety and security',#4892,$,$); -#4900=IFCCLASSIFICATIONREFERENCE($,'Ss_90_12','Hospitality demands',#4892,$,$); -#4901=IFCCLASSIFICATIONREFERENCE($,'Ss_90_13','Demand for information and communication',#4892,$,$); -#4902=IFCCLASSIFICATIONREFERENCE($,'Ss_90_14','Demand for logistics',#4892,$,$); -#4903=IFCCLASSIFICATIONREFERENCE($,'Ss_90_15','Demand for integrated management, consultancy and administration',#4892,$,$); -#4904=IFCCLASSIFICATIONREFERENCE($,'Ss_90_20','Specific demand of administrative, commercial and protective services',#4892,$,$); -#4905=IFCCLASSIFICATIONREFERENCE($,'Ss_90_25','Specific demand of cultural, educational, scientific and information organizations',#4892,$,$); -#4906=IFCCLASSIFICATIONREFERENCE($,'Ss_90_30','Specific demand of industrial organizations',#4892,$,$); -#4907=IFCCLASSIFICATIONREFERENCE($,'Ss_90_35','Specific demand of medical, health, welfare and sanitary organizations',#4892,$,$); -#4908=IFCCLASSIFICATIONREFERENCE($,'Ss_90_40','Specific demand of recreational organizations',#4892,$,$); -#4909=IFCCLASSIFICATIONREFERENCE($,'Ss_90_45','Specific demand of residential organizations',#4892,$,$); -#4910=IFCCLASSIFICATIONREFERENCE($,'Ss_90_50','Specific demand of disposal organizations',#4892,$,$); -#4911=IFCCLASSIFICATIONREFERENCE($,'Ss_90_55','Specific demand of piped supply organizations',#4892,$,$); -#4912=IFCCLASSIFICATIONREFERENCE($,'Ss_90_60','Specific demand of heating, cooling and refrigeration organizations',#4892,$,$); -#4913=IFCCLASSIFICATIONREFERENCE($,'Ss_90_65','Specific demand of ventilation and air conditioning organizations',#4892,$,$); -#4914=IFCCLASSIFICATIONREFERENCE($,'Ss_90_70','Specific demand of electrical organizations',#4892,$,$); -#4915=IFCCLASSIFICATIONREFERENCE($,'Ss_90_75','Specific demand of communications, security, safety and protection organisations',#4892,$,$); -#4916=IFCCLASSIFICATIONREFERENCE($,'Ss_90_80','Specific demand of rail organizations',#4892,$,$); -#4917=IFCCLASSIFICATIONREFERENCE($,'Ss_90_81','Specific demand of road organizations',#4892,$,$); -#4918=IFCCLASSIFICATIONREFERENCE($,'Ss_90_82','Specific demand of marine and waterway organizations',#4892,$,$); -#4919=IFCCLASSIFICATIONREFERENCE($,'Ss_90_83','Specific demand of cable transport organizations',#4892,$,$); -#4920=IFCCLASSIFICATIONREFERENCE($,'Ss_90_84','Specific demand of aerospace organizations',#4892,$,$); -#4921=IFCCLASSIFICATIONREFERENCE($,'Pr','Products',#1,$,$); -#4922=IFCCLASSIFICATIONREFERENCE($,'Pr_15','Preparatory products',#4921,$,$); -#4923=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31','Formless preparatory products',#4922,$,$); -#4924=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04','Applied cleaning and treatment products',#4923,$,$); -#4925=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_02','Acid neutralization products',#4924,$,$); -#4926=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_06','Biocidal cleaning solutions',#4924,$,$); -#4927=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_10','Chemical absorbent products',#4924,$,$); -#4928=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_11','Chemical cleaning gels and liquids',#4924,$,$); -#4929=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_12','Chemical poultices',#4924,$,$); -#4930=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_13','Cleaners',#4924,$,$); -#4931=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_14','Cleaning agents',#4924,$,$); -#4932=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_15','Concrete surface retarders',#4924,$,$); -#4933=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_16','Concrete treatment surface and injection chemicals',#4924,$,$); -#4934=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_20','Curing compounds',#4924,$,$); -#4935=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_23','De-icing chemicals',#4924,$,$); -#4936=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_34','Graffiti-removing chemicals',#4924,$,$); -#4937=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_35','Grit',#4924,$,$); -#4938=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_53','Mould removers',#4924,$,$); -#4939=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_58','Oil-absorbent products',#4924,$,$); -#4940=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_60','Paint strippers',#4924,$,$); -#4941=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_64','Plain poultices',#4924,$,$); -#4942=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_72','Rock salt',#4924,$,$); -#4943=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_77','Shampoos',#4924,$,$); -#4944=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_80','Snow clearing chemicals',#4924,$,$); -#4945=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_81','Solvents',#4924,$,$); -#4946=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_84','Spot-removing chemicals',#4924,$,$); -#4947=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_85','Sugar soap',#4924,$,$); -#4948=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_86','Surface cleaners',#4924,$,$); -#4949=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_12','Chemical soils stabilizers',#4923,$,$); -#4950=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_12_42','Injectable resinous soil stabilizers',#4949,$,$); -#4951=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26','Excavated earth and fill materials',#4923,$,$); -#4952=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_02','Asphalt arisings granular unbound mixtures',#4951,$,$); -#4953=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_07','Bentonite',#4951,$,$); -#4954=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_13','Chalk',#4951,$,$); -#4955=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_14','Clay',#4951,$,$); -#4956=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_15','Coarse no fines rubble fill materials',#4951,$,$); -#4957=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_17','Cohesive material',#4951,$,$); -#4958=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_18','Close-graded granular unbound mixtures',#4951,$,$); -#4959=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_26','Earth',#4951,$,$); -#4960=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_31','Glass bottles',#4951,$,$); -#4961=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_33','Graded granular fill materials',#4951,$,$); -#4962=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_34','Graded natural granular fill materials',#4951,$,$); -#4963=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_35','Graded recycled granular fill materials',#4951,$,$); -#4964=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_36','Hardcore',#4951,$,$); -#4965=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_39','Higher fines content well-graded granular mixtures',#4951,$,$); -#4966=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_42','Hoggin',#4951,$,$); -#4967=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_46','Landscape area fill materials',#4951,$,$); -#4968=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_50','Made ground',#4951,$,$); -#4969=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_58','Open-graded granular unbound mixtures',#4951,$,$); -#4970=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_71','River deposits',#4951,$,$); -#4971=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_75','Sand',#4951,$,$); -#4972=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_90','Topsoil',#4951,$,$); -#4973=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_96','Well-graded granular unbound mixtures',#4951,$,$); -#4974=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57','Non-rigid sheet, mat and strip preparatory products',#4922,$,$); -#4975=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_04','Applied cleaning and repair products',#4974,$,$); -#4976=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_04_34','Graffiti-removing wipes',#4975,$,$); -#4977=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_25','Geocells',#4974,$,$); -#4978=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_25_03','Acrylonitrile butadiene styrene (ABS) geocell boards',#4977,$,$); -#4979=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_25_04','Acrylonitrile butadiene styrene (ABS) geocell sheets',#4977,$,$); -#4980=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_25_32','Geocell boards',#4977,$,$); -#4981=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_25_33','Geocell sheets',#4977,$,$); -#4982=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_25_35','Heavy-duty polystyrene geocell boards',#4977,$,$); -#4983=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_25_36','Heavy-duty polystyrene geocell sheets',#4977,$,$); -#4984=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_25_39','High density polyethylene (PE-HD) geocell boards',#4977,$,$); -#4985=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_25_40','High density polyethylene (PE-HD) geocell sheets',#4977,$,$); -#4986=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_25_57','Needle-punched polyester linen',#4977,$,$); -#4987=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_25_70','Polyester strips',#4977,$,$); -#4988=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_25_74','Polypropylene geocell boards',#4977,$,$); -#4989=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_25_75','Polypropylene geocell sheets',#4977,$,$); -#4990=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_27','Geocomposites',#4974,$,$); -#4991=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_27_33','Geocomposite sheets',#4990,$,$); -#4992=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_27_36','Geocomposite studded sheets',#4990,$,$); -#4993=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_27_38','Geomembrane geogrid composite sheets',#4990,$,$); -#4994=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_27_39','Geosynthetic clay liners (GCLs)',#4990,$,$); -#4995=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_27_43','Geotextile geogrid composite sheets',#4990,$,$); -#4996=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_27_45','Geotextile geomembrane composite sheets',#4990,$,$); -#4997=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_27_47','Geotextile geonet composite sheets',#4990,$,$); -#4998=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_27_49','Geotextile plastics composite sheets',#4990,$,$); -#4999=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_27_60','Plastics geocomposite sheets',#4990,$,$); -#5000=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_30','Geomembranes',#4974,$,$); -#5001=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_33','Geosynthetics',#4974,$,$); -#5002=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_33_36','Geogrids',#5001,$,$); -#5003=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_33_37','Geomats',#5001,$,$); -#5004=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_33_38','Geonets',#5001,$,$); -#5005=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_33_41','High density polyethylene (PE-HD) geogrids',#5001,$,$); -#5006=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_33_42','High density polyethylene (PE-HD) geonets',#5001,$,$); -#5007=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_33_64','Plastics geogrids',#5001,$,$); -#5008=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_33_75','Polyester geogrids',#5001,$,$); -#5009=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_33_77','Polyethylene geomats',#5001,$,$); -#5010=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_33_79','Polymeric rib geonets',#5001,$,$); -#5011=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_33_80','Polyolefin geomats',#5001,$,$); -#5012=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_33_85','Spun-bonded polypropylene (PP) membranes',#5001,$,$); -#5013=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_33_97','Woven polypropylene (PP) membranes',#5001,$,$); -#5014=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_35','Geotextiles',#4974,$,$); -#5015=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_35_56','Natural material geotextiles',#5014,$,$); -#5016=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_35_57','Needle-punched nonwoven geotextiles',#5014,$,$); -#5017=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_35_61','Plastics geotextiles',#5014,$,$); -#5018=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_35_88','Thermally-bonded nonwoven geotextiles',#5014,$,$); -#5019=IFCCLASSIFICATIONREFERENCE($,'Pr_15_71','Rigid board, panel and sheet preparatory products',#4922,$,$); -#5020=IFCCLASSIFICATIONREFERENCE($,'Pr_15_71_90','Trench boards and sheets',#5019,$,$); -#5021=IFCCLASSIFICATIONREFERENCE($,'Pr_15_71_90_90','Trench boards',#5020,$,$); -#5022=IFCCLASSIFICATIONREFERENCE($,'Pr_15_71_90_91','Trench sheets',#5020,$,$); -#5023=IFCCLASSIFICATIONREFERENCE($,'Pr_15_93','Unit preparatory products',#4922,$,$); -#5024=IFCCLASSIFICATIONREFERENCE($,'Pr_15_93_30','Fill blocks',#5023,$,$); -#5025=IFCCLASSIFICATIONREFERENCE($,'Pr_15_93_30_28','Expanded polystyrene (EPS) fill blocks',#5024,$,$); -#5026=IFCCLASSIFICATIONREFERENCE($,'Pr_20','Structure and general products',#4921,$,$); -#5027=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29','Fastener products',#5026,$,$); -#5028=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03','Anchors and components',#5027,$,$); -#5029=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_04','Anchor blocks',#5028,$,$); -#5030=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_05','Anchor rails',#5028,$,$); -#5031=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_10','Carbon steel anchor plates',#5028,$,$); -#5032=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_11','Carbon steel chemical anchor rods',#5028,$,$); -#5033=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_12','Carbon steel chemical anchor sockets',#5028,$,$); -#5034=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_13','Carbon steel post base plates',#5028,$,$); -#5035=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_14','Carbon steel post spikes',#5028,$,$); -#5036=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_15','Cavity anchors',#5028,$,$); -#5037=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_16','Chemical anchor capsules',#5028,$,$); -#5038=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_17','Chemical anchor cartridges',#5028,$,$); -#5039=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_18','Chemical anchors',#5028,$,$); -#5040=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_28','Expansion anchors',#5028,$,$); -#5041=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_30','Fixing discs',#5028,$,$); -#5042=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_31','Framing anchors',#5028,$,$); -#5043=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_32','Framing fasteners',#5028,$,$); -#5044=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_33','Ground anchor heads',#5028,$,$); -#5045=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_34','Ground plate anchors',#5028,$,$); -#5046=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_35','Grouted ground anchors',#5028,$,$); -#5047=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_36','Hammer-in fasteners',#5028,$,$); -#5048=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_44','J-pins',#5028,$,$); -#5049=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_47','Lifting anchors',#5028,$,$); -#5050=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_48','Lifting hoops',#5028,$,$); -#5051=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_66','Prestressing anchors',#5028,$,$); -#5052=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_72','Rock bolts',#5028,$,$); -#5053=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_73','Rock dowels',#5028,$,$); -#5054=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_77','Socket anchors',#5028,$,$); -#5055=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_78','Solar module roof anchors',#5028,$,$); -#5056=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_79','Split rings',#5028,$,$); -#5057=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_80','Sprayed concrete anchor studs',#5028,$,$); -#5058=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_81','Sprayed concrete ties',#5028,$,$); -#5059=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_82','Stainless steel anchor plates',#5028,$,$); -#5060=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_83','Stainless steel chemical anchor rods',#5028,$,$); -#5061=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_84','Stainless steel chemical anchor sockets',#5028,$,$); -#5062=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_86','Structural anchors',#5028,$,$); -#5063=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_88','Threaded anchors',#5028,$,$); -#5064=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_92','Undercut anchors',#5028,$,$); -#5065=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_97','Wedge anchors',#5028,$,$); -#5066=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_04','Angle fasteners',#5027,$,$); -#5067=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_04_26','Equal angles fasteners',#5066,$,$); -#5068=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_04_27','Equipment fasteners',#5066,$,$); -#5069=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08','Bolts and accessories',#5027,$,$); -#5070=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_04','Anchor bolts',#5069,$,$); -#5071=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_07','Black hexagon nuts and bolts',#5069,$,$); -#5072=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_08','Bolt boxes',#5069,$,$); -#5073=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_11','Carbon steel hexagon headed nuts and bolts',#5069,$,$); -#5074=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_12','Carbon steel hook bolts (J-bolts)',#5069,$,$); -#5075=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_15','Coach (carriage) bolts and nuts',#5069,$,$); -#5076=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_18','Crossing bolts',#5069,$,$); -#5077=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_26','Elevator bolts',#5069,$,$); -#5078=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_27','Eye bolts',#5069,$,$); -#5079=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_28','Expanding bolts',#5069,$,$); -#5080=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_30','Fishplate bolts',#5069,$,$); -#5081=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_32','Flangeway bolts',#5069,$,$); -#5082=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_36','Hanger bolts',#5069,$,$); -#5083=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_38','Holding down bolt assemblies',#5069,$,$); -#5084=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_42','Indented bolts',#5069,$,$); -#5085=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_46','Lag bolts',#5069,$,$); -#5086=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_57','Nylon gutter bolts',#5069,$,$); -#5087=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_66','Preloaded bolt assemblies',#5069,$,$); -#5088=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_70','Rail securing bolts',#5069,$,$); -#5089=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_78','Shoulder bolts',#5069,$,$); -#5090=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_83','Stainless steel gutter bolts',#5069,$,$); -#5091=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_84','Stainless steel hexagon headed nuts and bolts',#5069,$,$); -#5092=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_85','Stainless steel hook bolts (J-bolts)',#5069,$,$); -#5093=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_86','Stud bolts',#5069,$,$); -#5094=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_92','U-bolts',#5069,$,$); -#5095=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_10','Bridge suspension cable accessories',#5027,$,$); -#5096=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_10_11','Cable sleeves',#5095,$,$); -#5097=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_10_12','Cable strand sockets',#5095,$,$); -#5098=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_10_13','Cast steel anchorage couplers',#5095,$,$); -#5099=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_10_14','Cast steel cable bands',#5095,$,$); -#5100=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_10_15','Cast steel saddles',#5095,$,$); -#5101=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_10_16','Cast steel suspender sockets',#5095,$,$); -#5102=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_10_21','Dampers',#5095,$,$); -#5103=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_10_79','Sleeve clamps',#5095,$,$); -#5104=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14','Clips, clamps and couplers',#5027,$,$); -#5105=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_07','Beam clamps',#5104,$,$); -#5106=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_08','Beam clips',#5104,$,$); -#5107=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_13','Circlips',#5104,$,$); -#5108=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_15','Coupler connections',#5104,$,$); -#5109=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_16','Colour pipe clips',#5104,$,$); -#5110=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_17','Copper clips',#5104,$,$); -#5111=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_22','Deck board clips',#5104,$,$); -#5112=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_24','Drainage pipe clips',#5104,$,$); -#5113=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_30','Fence panel clips',#5104,$,$); -#5114=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_31','Floor clips',#5104,$,$); -#5115=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_32','Frame cramps',#5104,$,$); -#5116=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_33','Glass panel fixing clips',#5104,$,$); -#5117=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_34','Glass-to-glass clips',#5104,$,$); -#5118=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_35','Glass-to-wall clips',#5104,$,$); -#5119=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_36','Girder clamps',#5104,$,$); -#5120=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_40','Iron clips',#5104,$,$); -#5121=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_45','Lift-off panel clips',#5104,$,$); -#5122=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_50','Masonry cramps',#5104,$,$); -#5123=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_65','Pipe clips',#5104,$,$); -#5124=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_68','Push-fit panel clips',#5104,$,$); -#5125=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_76','Security glazing clips',#5104,$,$); -#5126=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_79','Shackles',#5104,$,$); -#5127=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_82','Stainless steel spring clips',#5104,$,$); -#5128=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_84','Standing seam fixed clips',#5104,$,$); -#5129=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_85','Standing seam sliding clips',#5104,$,$); -#5130=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_86','Steel clips',#5104,$,$); -#5131=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_87','Suspended ceiling clips',#5104,$,$); -#5132=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_90','Truss clips',#5104,$,$); -#5133=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23','Dowels and rods',#5027,$,$); -#5134=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_11','Carbon steel dowel bars',#5133,$,$); -#5135=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_12','Carbon steel rods',#5133,$,$); -#5136=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_22','Dowel bar caps',#5133,$,$); -#5137=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_23','Dowel-retaining fasteners',#5133,$,$); -#5138=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_30','Fibre-reinforced plastics dowels',#5133,$,$); -#5139=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_36','Hardwood dowels',#5133,$,$); -#5140=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_40','Hot welding rods',#5133,$,$); -#5141=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_50','Masonry dowels',#5133,$,$); -#5142=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_52','Metal dowels, pins and rods',#5133,$,$); -#5143=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_65','Plastics dowel bar caps',#5133,$,$); -#5144=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_80','Softwood dowels',#5133,$,$); -#5145=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_83','Stainless steel dowel bars',#5133,$,$); -#5146=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_84','Stainless steel rods',#5133,$,$); -#5147=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_92','U-pins',#5133,$,$); -#5148=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_29','Ferrules and sleeves',#5027,$,$); -#5149=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_29_23','Dowel bar sleeves',#5148,$,$); -#5150=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_29_29','Ferrules',#5148,$,$); -#5151=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_29_62','Plastics pile sleeves',#5148,$,$); -#5152=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_29_66','Pre-stressed reinforcement cable conduits',#5148,$,$); -#5153=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_29_84','Spacer sleeves',#5148,$,$); -#5154=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_29_96','Wire-crimp ferrules',#5148,$,$); -#5155=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_30','Fixing lugs',#5027,$,$); -#5156=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_30_11','Cable fixing lugs',#5155,$,$); -#5157=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_30_12','Carbon steel fixing lugs',#5155,$,$); -#5158=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_30_24','Door fixing lugs',#5155,$,$); -#5159=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_30_31','Furniture floor fixing lugs',#5155,$,$); -#5160=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_30_32','Furniture wall fixing lugs',#5155,$,$); -#5161=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_30_96','Window fixing lugs',#5155,$,$); -#5162=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_31','Flat and folded plate fasteners',#5027,$,$); -#5163=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_31_08','Bolted joint connectors',#5162,$,$); -#5164=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_31_12','Carbon steel nailing plates',#5162,$,$); -#5165=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_31_13','Carbon steel punched metal plate fasteners',#5162,$,$); -#5166=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_31_44','Joist hangers',#5162,$,$); -#5167=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_31_52','Mortise and tenon joint oak pegs',#5162,$,$); -#5168=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_31_84','Stainless steel nailing plates',#5162,$,$); -#5169=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_31_85','Stainless steel punched metal plate fasteners',#5162,$,$); -#5170=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_34','Glass fixing plates, brackets and anchors',#5027,$,$); -#5171=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_34_16','Cast brass glass fixing brackets',#5170,$,$); -#5172=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_34_34','Glass fin splice plates',#5170,$,$); -#5173=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_34_35','Glass patch plates',#5170,$,$); -#5174=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_34_85','Stainless steel glass block panel anchors',#5170,$,$); -#5175=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_34_86','Stainless steel point connectors',#5170,$,$); -#5176=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56','Nails',#5027,$,$); -#5177=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_02','Aluminium nails',#5176,$,$); -#5178=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_03','Annular nails',#5176,$,$); -#5179=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_11','Carbon steel nails',#5176,$,$); -#5180=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_12','Carbon steel wire nails',#5176,$,$); -#5181=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_14','Clout head nails',#5176,$,$); -#5182=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_15','Copper nails',#5176,$,$); -#5183=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_16','Corrugated fasteners',#5176,$,$); -#5184=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_19','Cut clasp nails',#5176,$,$); -#5185=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_20','Cut floor brads',#5176,$,$); -#5186=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_36','Hardboard nails',#5176,$,$); -#5187=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_48','Lost head (round) nails',#5176,$,$); -#5188=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_50','Masonry nails',#5176,$,$); -#5189=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_59','Oval wire nails',#5176,$,$); -#5190=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_60','Panel pins',#5176,$,$); -#5191=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_65','Power driven nails',#5176,$,$); -#5192=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_78','Shot-fire nails',#5176,$,$); -#5193=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_82','Sprigs',#5176,$,$); -#5194=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_83','Spring-head roofing nails',#5176,$,$); -#5195=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_84','Square twisted nails',#5176,$,$); -#5196=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_85','Stainless steel nails',#5176,$,$); -#5197=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_86','Staples',#5176,$,$); -#5198=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_87','Tacks',#5176,$,$); -#5199=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_93','Upholstery nails',#5176,$,$); -#5200=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57','Nuts',#5027,$,$); -#5201=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_01','Acorn nuts',#5200,$,$); -#5202=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_02','Aerotite nuts',#5200,$,$); -#5203=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_11','Cage nuts',#5200,$,$); -#5204=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_12','Captive nuts',#5200,$,$); -#5205=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_13','Castle nuts',#5200,$,$); -#5206=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_23','Dome (cap) nuts',#5200,$,$); -#5207=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_30','Flange nuts',#5200,$,$); -#5208=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_35','Hard lock nuts',#5200,$,$); -#5209=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_36','Half nuts',#5200,$,$); -#5210=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_37','Heavy hex nuts',#5200,$,$); -#5211=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_38','Hex nuts',#5200,$,$); -#5212=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_44','Jam nuts',#5200,$,$); -#5213=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_45','K-lock nuts',#5200,$,$); -#5214=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_50','Manifold nuts',#5200,$,$); -#5215=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_56','Nylon-insert jam nuts',#5200,$,$); -#5216=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_57','Nylon-insert lock nuts',#5200,$,$); -#5217=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_66','Prevailing torque lock nuts',#5200,$,$); -#5218=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_75','Self-locking nuts',#5200,$,$); -#5219=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_76','Serrated flange nuts',#5200,$,$); -#5220=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_80','Slotted nuts',#5200,$,$); -#5221=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_83','Square nuts',#5200,$,$); -#5222=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_84','Stover nuts',#5200,$,$); -#5223=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_85','Stud connector (coupling) nuts',#5200,$,$); -#5224=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_88','Tee nuts',#5200,$,$); -#5225=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_96','Wing nuts',#5200,$,$); -#5226=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60','Packings, washers and spacers',#5027,$,$); -#5227=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_07','Bituminous felt packers',#5226,$,$); -#5228=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_17','Crinkle washers',#5226,$,$); -#5229=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_20','Cup (finishing) washers',#5226,$,$); -#5230=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_28','External tooth lock (shake-proof) washers',#5226,$,$); -#5231=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_29','Fender washers',#5226,$,$); -#5232=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_30','Fibre washers',#5226,$,$); -#5233=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_31','Flat washers',#5226,$,$); -#5234=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_32','Formwork cover spacers',#5226,$,$); -#5235=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_34','Grommets',#5226,$,$); -#5236=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_36','Hardwood packers',#5226,$,$); -#5237=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_37','Hardwood wedges',#5226,$,$); -#5238=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_42','Internal tooth lock (shake-proof) washers',#5226,$,$); -#5239=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_58','Ogee washers',#5226,$,$); -#5240=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_59','Open push',#5226,$,$); -#5241=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_60','Packings',#5226,$,$); -#5242=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_61','Parallel circumferential packings',#5226,$,$); -#5243=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_62','Penny (dock) washers',#5226,$,$); -#5244=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_63','Plate (square) washers',#5226,$,$); -#5245=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_64','Plywood packers',#5226,$,$); -#5246=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_65','Polyethylene packers',#5226,$,$); -#5247=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_75','Serrated washers',#5226,$,$); -#5248=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_76','Sealing washers',#5226,$,$); -#5249=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_77','Shims and folding wedges',#5226,$,$); -#5250=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_81','Softwood packs',#5226,$,$); -#5251=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_82','Softwood wedges',#5226,$,$); -#5252=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_84','Sprung (split lock) washers',#5226,$,$); -#5253=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_87','Tapered circumferential packings',#5226,$,$); -#5254=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_96','Washers',#5226,$,$); -#5255=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_63','Plugs',#5027,$,$); -#5256=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_63_50','Masonry plugs',#5255,$,$); -#5257=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_63_63','Plastics plugs',#5255,$,$); -#5258=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_63_84','Studded cavity drainage membrane plugs',#5255,$,$); -#5259=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_63_85','Surface plugs and pellets',#5255,$,$); -#5260=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70','Rail fasteners',#5027,$,$); -#5261=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_02','Adjustable rail clips',#5260,$,$); -#5262=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_09','Bull head rail keys',#5260,$,$); -#5263=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_11','Cast-in rail clip shoulders',#5260,$,$); -#5264=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_13','Clamp brackets',#5260,$,$); -#5265=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_22','Distance block bolts',#5260,$,$); -#5266=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_31','Fishplates',#5260,$,$); -#5267=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_32','Fishwashers',#5260,$,$); -#5268=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_36','Heel blocks',#5260,$,$); -#5269=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_37','Heel block bolts',#5260,$,$); -#5270=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_41','Insulated fishplates',#5260,$,$); -#5271=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_46','Long defect fishplates',#5260,$,$); -#5272=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_68','Rail anchors',#5260,$,$); -#5273=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_69','Rail clamp assemblies',#5260,$,$); -#5274=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_70','Rail clips',#5260,$,$); -#5275=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_72','Rail joint clamps',#5260,$,$); -#5276=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_73','Rail foot insulators',#5260,$,$); -#5277=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_85','Stock rail anchor bolts',#5260,$,$); -#5278=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_87','Switch rail anchor',#5260,$,$); -#5279=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_96','Weldable rail clip shoulders',#5260,$,$); -#5280=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_71','Rivets',#5027,$,$); -#5281=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_71_08','Blind (pop) rivets',#5280,$,$); -#5282=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_71_24','Drive rivets',#5280,$,$); -#5283=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_71_30','Flush rivets',#5280,$,$); -#5284=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_71_31','Friction rivets',#5280,$,$); -#5285=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_71_59','Oscar rivets',#5280,$,$); -#5286=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_71_76','Self-pierce rivets',#5280,$,$); -#5287=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_71_77','Semi-tubular rivets',#5280,$,$); -#5288=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_71_81','Solid rivets',#5280,$,$); -#5289=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76','Screws',#5027,$,$); -#5290=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_11','Carbon steel hexagon head screws',#5289,$,$); -#5291=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_15','Coach screws',#5289,$,$); -#5292=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_28','Eye lags',#5289,$,$); -#5293=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_50','Machine screws',#5289,$,$); -#5294=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_65','Plasterboard screws',#5289,$,$); -#5295=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_72','Rigging screws',#5289,$,$); -#5296=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_75','Self-tapping screws',#5289,$,$); -#5297=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_76','Self-drilling screws',#5289,$,$); -#5298=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_77','Set screws',#5289,$,$); -#5299=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_78','Sheet metal screws',#5289,$,$); -#5300=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_81','Socket screws',#5289,$,$); -#5301=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_85','Stainless steel hexagon head screws',#5289,$,$); -#5302=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_86','Stainless steel screws',#5289,$,$); -#5303=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_88','Thread-cutting machine screws',#5289,$,$); -#5304=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_98','Wood screws',#5289,$,$); -#5305=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_81','Soil nails',#5027,$,$); -#5306=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_81_11','Carbon steel soil nails',#5305,$,$); -#5307=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_81_63','Plastics soil nails',#5305,$,$); -#5308=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_81_84','Stainless steel soil nails',#5305,$,$); -#5309=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_85','Straw bale fixings',#5027,$,$); -#5310=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_85_64','Plastics sleeving',#5309,$,$); -#5311=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_85_65','Polyester straps',#5309,$,$); -#5312=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_87','Thatch roofing fasteners',#5027,$,$); -#5313=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_87_36','Hazel staples',#5312,$,$); -#5314=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_87_37','Hazel sways',#5312,$,$); -#5315=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_87_52','Metal sways',#5312,$,$); -#5316=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_87_87','Thatching hooks',#5312,$,$); -#5317=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_87_96','Willow sways',#5312,$,$); -#5318=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88','Tile and fabric fasteners',#5027,$,$); -#5319=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_26','Edge beading',#5318,$,$); -#5320=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_27','Edge beading rails',#5318,$,$); -#5321=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_31','Forked roofing connectors',#5318,$,$); -#5322=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_37','Hip irons',#5318,$,$); -#5323=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_41','Insulation fixing saddle clips',#5318,$,$); -#5324=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_42','Insulation fixing spikes',#5318,$,$); -#5325=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_43','Insulation fixing straps',#5318,$,$); -#5326=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_59','Overlay fasteners',#5318,$,$); -#5327=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_70','Roofing belts',#5318,$,$); -#5328=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_71','Roofing clamps',#5318,$,$); -#5329=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_72','Roofing clamping plates',#5318,$,$); -#5330=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_73','Roofing corner plates',#5318,$,$); -#5331=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_74','Roofing straps',#5318,$,$); -#5332=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_75','Roofing swags',#5318,$,$); -#5333=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_96','Welded joints',#5027,$,$); -#5334=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_96_03','Aluminothermic rail welds',#5333,$,$); -#5335=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_97','Welding joint fillers',#5027,$,$); -#5336=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_97_09','Brazing joint fillers',#5335,$,$); -#5337=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_97_26','Electric welding joint fillers',#5335,$,$); -#5338=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_97_33','Gas welding joint fillers',#5335,$,$); -#5339=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_97_81','Soldering joint fillers',#5335,$,$); -#5340=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31','Formless structure and general products',#5026,$,$); -#5341=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_01','Additives',#5340,$,$); -#5342=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_01_11','Carbon steel fibres',#5341,$,$); -#5343=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_01_22','Dust suppression additive',#5341,$,$); -#5344=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_01_32','Glass fibres',#5341,$,$); -#5345=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_01_39','Hydraulic road binders',#5341,$,$); -#5346=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_01_75','Polypropylene (PP) fibres',#5341,$,$); -#5347=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_01_85','Stainless steel fibres',#5341,$,$); -#5348=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_01_86','Synthetic fibres',#5341,$,$); -#5349=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_01_96','Waterborne absorption fluids',#5341,$,$); -#5350=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_01_99','Zinc powders',#5341,$,$); -#5351=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02','Adhesives and bonding compounds',#5340,$,$); -#5352=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_02','Acrylic anaerobic adhesives',#5351,$,$); -#5353=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_03','Acrylic and methacrylate adhesives',#5351,$,$); -#5354=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_04','All-purpose pastes',#5351,$,$); -#5355=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_06','Bio-resin adhesives',#5351,$,$); -#5356=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_07','Bitumen bonding compounds',#5351,$,$); -#5357=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_08','Bitumen-based bonding compounds',#5351,$,$); -#5358=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_09','Bitumen rubber emulsion adhesives',#5351,$,$); -#5359=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_11','Casein adhesives',#5351,$,$); -#5360=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_12','Cementitious adhesives',#5351,$,$); -#5361=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_13','Cementitious bonding compounds',#5351,$,$); -#5362=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_15','Cold-applied bitumen bonding compounds',#5351,$,$); -#5363=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_18','Cold water pastes',#5351,$,$); -#5364=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_21','Damp proof course joint sealer adhesives',#5351,$,$); -#5365=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_26','Epoxy resin-based adhesives',#5351,$,$); -#5366=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_28','Epoxy resin-based bonding compounds',#5351,$,$); -#5367=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_29','Epoxy resin ballast glues',#5351,$,$); -#5368=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_35','Gypsum-based adhesives',#5351,$,$); -#5369=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_36','Heavy-duty pastes',#5351,$,$); -#5370=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_37','Hot-applied bitumen bonding compounds',#5351,$,$); -#5371=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_38','High-performance ready-mixed adhesives',#5351,$,$); -#5372=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_50','Masonry injection resins',#5351,$,$); -#5373=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_52','Modified silane (MS) polymer adhesives',#5351,$,$); -#5374=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_56','Natural rubber-based and latex adhesives',#5351,$,$); -#5375=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_57','Non bitumen-based bonding compounds',#5351,$,$); -#5376=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_59','Overlap and border adhesives',#5351,$,$); -#5377=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_60','Parchment size',#5351,$,$); -#5378=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_61','Phenolic, resorcinol and formaldehyde-based resin (PRF) thermosetting adhesives',#5351,$,$); -#5379=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_62','Polyurethane (PUR) adhesives',#5351,$,$); -#5380=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_63','Polyurethane (PUR) ballast reinforcement',#5351,$,$); -#5381=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_64','Polyurethane (PUR) based resin binders',#5351,$,$); -#5382=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_65','Polyvinyl acetate (PVAc) adhesives',#5351,$,$); -#5383=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_66','Polyvinyl acetate (PVAc) bonding compounds',#5351,$,$); -#5384=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_71','Resin binders',#5351,$,$); -#5385=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_76','Sodium silicate binders',#5351,$,$); -#5386=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_80','Solvent-based synthetic rubber resin adhesives',#5351,$,$); -#5387=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_81','Solvent-free cellulose adhesives',#5351,$,$); -#5388=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_82','Solvent-free synthetic rubber resin adhesives',#5351,$,$); -#5389=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_84','Styrene butadiene rubber (SBR) bonding compounds',#5351,$,$); -#5390=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_85','Synthetic bonding compounds',#5351,$,$); -#5391=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_89','Tile adhesives',#5351,$,$); -#5392=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_94','Vermiculite-based adhesives',#5351,$,$); -#5393=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_95','Vinyl adhesives',#5351,$,$); -#5394=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_97','Welding paste and solvents',#5351,$,$); -#5395=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03','Admixtures',#5340,$,$); -#5396=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_01','Adherence proofing concrete admixtures',#5395,$,$); -#5397=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_02','Air entraining and plasticizing concrete admixtures',#5395,$,$); -#5398=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_03','Air entraining and plasticizing mortar and screed admixtures',#5395,$,$); -#5399=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_15','Concrete expanding agents',#5395,$,$); -#5400=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_16','Concrete foaming agents',#5395,$,$); -#5401=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_17','Corrosion inhibiting admixtures',#5395,$,$); -#5402=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_31','Frostproofing concrete admixtures',#5395,$,$); -#5403=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_36','Hardening and accelerating concrete admixtures',#5395,$,$); -#5404=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_38','High range water reducing and superplasticizing concrete admixtures',#5395,$,$); -#5405=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_52','Mid-range water reducing and superplasticizing concrete admixtures',#5395,$,$); -#5406=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_58','Oil proofing concrete admixtures',#5395,$,$); -#5407=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_64','Polymer admixtures',#5395,$,$); -#5408=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_76','Set-accelerating concrete admixtures',#5395,$,$); -#5409=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_77','Set-accelerating, water reducing and plasticizing concrete admixtures',#5395,$,$); -#5410=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_78','Set-retarding concrete, mortar and plaster admixtures',#5395,$,$); -#5411=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_79','Set-retarding, high range water reducing and superplasticizing concrete admixtures',#5395,$,$); -#5412=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_80','Set-retarding, water reducing and plasticizing concrete admixtures',#5395,$,$); -#5413=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_84','Sprayed concrete admixtures',#5395,$,$); -#5414=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_94','Viscosity modifying admixtures',#5395,$,$); -#5415=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_95','Waterproofing concrete admixtures',#5395,$,$); -#5416=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_96','Waterproofing mortar admixtures',#5395,$,$); -#5417=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_97','Water-reducing and plasticizing concrete admixtures',#5395,$,$); -#5418=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_98','Water-retaining concrete admixtures',#5395,$,$); -#5419=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04','Aggregates',#5340,$,$); -#5420=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_01','Air cooled steel slag',#5419,$,$); -#5421=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_02','All-in normal and heavyweight aggregates',#5419,$,$); -#5422=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_04','Armourstone coarse aggregates',#5419,$,$); -#5423=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_05','Barytes aggregates',#5419,$,$); -#5424=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_06','Base, bed and fill all-in aggregates',#5419,$,$); -#5425=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_07','Base, bed and fill coarse aggregates',#5419,$,$); -#5426=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_08','Base, bed and fill fine aggregates',#5419,$,$); -#5427=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_09','Blinding coarse aggregates',#5419,$,$); -#5428=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_10','Blinding fine aggregates',#5419,$,$); -#5429=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_11','Bonded surfacing decorative aggregates',#5419,$,$); -#5430=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_13','Coarse general aggregates',#5419,$,$); -#5431=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_15','Coarse lightweight aggregates for concrete and mortar',#5419,$,$); -#5432=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_16','Coarse normal and heavyweight aggregates',#5419,$,$); -#5433=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_20','Crushed stone aggregates',#5419,$,$); -#5434=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_25','Expanded clay lightweight aggregates',#5419,$,$); -#5435=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_26','Expanded glass aggregates',#5419,$,$); -#5436=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_27','Expanded slag aggregates',#5419,$,$); -#5437=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_28','Expanded slate aggregates',#5419,$,$); -#5438=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_29','Fine aggregates',#5419,$,$); -#5439=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_30','Fine general aggregates',#5419,$,$); -#5440=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_31','Fine lightweight aggregates for concrete and mortar',#5419,$,$); -#5441=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_32','Fine normal and heavyweight aggregates',#5419,$,$); -#5442=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_35','Granular cork aggregates',#5419,$,$); -#5443=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_42','Iron ore aggregates',#5419,$,$); -#5444=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_44','Jointing fine aggregates',#5419,$,$); -#5445=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_46','Laying course fine aggregates',#5419,$,$); -#5446=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_48','Loose surfacing decorative aggregates',#5419,$,$); -#5447=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_51','Mortar aggregates',#5419,$,$); -#5448=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_52','Mortar coarse aggregates',#5419,$,$); -#5449=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_53','Mortar fine aggregates',#5419,$,$); -#5450=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_56','Natural stone aggregates',#5419,$,$); -#5451=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_57','Natural stone dusts',#5419,$,$); -#5452=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_59','Oyster shells',#5419,$,$); -#5453=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_60','Pea gravel',#5419,$,$); -#5454=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_61','Perlite aggregates',#5419,$,$); -#5455=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_62','Permeable laying course aggregates',#5419,$,$); -#5456=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_71','Recycled lightweight aggregates',#5419,$,$); -#5457=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_72','Recycled rubber granules',#5419,$,$); -#5458=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_77','Scrap iron aggregates',#5419,$,$); -#5459=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_79','Single sized aggregates',#5419,$,$); -#5460=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_80','Soil amelioration aggregates',#5419,$,$); -#5461=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_85','Surface dressing aggregates',#5419,$,$); -#5462=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_86','Surface treatment fine aggregates',#5419,$,$); -#5463=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_94','Vermiculite aggregates',#5419,$,$); -#5464=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_12','Cements and limes',#5340,$,$); -#5465=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_12_11','Calcium aluminate cements',#5464,$,$); -#5466=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_12_13','Cement/cement replacement materials',#5464,$,$); -#5467=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_12_38','Hydrated limes',#5464,$,$); -#5468=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_12_39','Hydraulic limes',#5464,$,$); -#5469=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_12_50','Masonry cements',#5464,$,$); -#5470=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_12_57','Non-hydraulic lime putties',#5464,$,$); -#5471=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_12_58','Non-hydraulic limes',#5464,$,$); -#5472=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_12_60','Portland cements',#5464,$,$); -#5473=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_12_69','Quicklime',#5464,$,$); -#5474=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_12_80','Special purpose cements',#5464,$,$); -#5475=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_12_86','Sulfate-resisting Portland cements',#5464,$,$); -#5476=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16','Concretes',#5340,$,$); -#5477=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_12','Cement-bound granular mixtures',#5476,$,$); -#5478=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_21','Designated concrete',#5476,$,$); -#5479=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_22','Designed concrete',#5476,$,$); -#5480=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_29','Fine bedding concretes',#5476,$,$); -#5481=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_30','Fly ash bound mixtures',#5476,$,$); -#5482=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_31','Foamed concrete',#5476,$,$); -#5483=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_37','High strength concrete',#5476,$,$); -#5484=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_39','Hydraulic road binder bound mixtures',#5476,$,$); -#5485=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_56','Normal-class concretes',#5476,$,$); -#5486=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_66','Pre-blended concretes',#5476,$,$); -#5487=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_67','Prescribed concrete',#5476,$,$); -#5488=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_68','Proprietary concretes',#5476,$,$); -#5489=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_70','Resin concretes',#5476,$,$); -#5490=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_72','Roman concretes',#5476,$,$); -#5491=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_76','Self-compacting concretes',#5476,$,$); -#5492=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_78','Slag bound mixtures',#5476,$,$); -#5493=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_80','Small-area repair concretes',#5476,$,$); -#5494=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_82','Special-class performance concretes',#5476,$,$); -#5495=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_83','Special-class prescription concretes',#5476,$,$); -#5496=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_84','Sprayed concretes',#5476,$,$); -#5497=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_85','Standardized prescribed concrete',#5476,$,$); -#5498=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_92','Ultra high performance concrete',#5476,$,$); -#5499=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35','Granules and powders',#5340,$,$); -#5500=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_11','Carborundum',#5499,$,$); -#5501=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_22','Diatomaceous earth',#5499,$,$); -#5502=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_30','Fly ash',#5499,$,$); -#5503=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_33','Granulated blast furnace slag',#5499,$,$); -#5504=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_34','Ground granulated blast furnace slag',#5499,$,$); -#5505=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_35','Gypsum',#5499,$,$); -#5506=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_47','Limestone fines',#5499,$,$); -#5507=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_50','Marble dust',#5499,$,$); -#5508=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_51','Metakaolin',#5499,$,$); -#5509=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_52','Microsilica',#5499,$,$); -#5510=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_53','Mineral pigments',#5499,$,$); -#5511=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_56','Natural pozzolan',#5499,$,$); -#5512=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_60','Partially ground granulated blast furnace slag',#5499,$,$); -#5513=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_62','Plaster of Paris',#5499,$,$); -#5514=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_75','Sawdust',#5499,$,$); -#5515=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_81','Silica fume',#5499,$,$); -#5516=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_82','Sintered pulverized fuel ash',#5499,$,$); -#5517=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_86','Synthetic foam granules',#5499,$,$); -#5518=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53','Mortars and grouts',#5340,$,$); -#5519=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_08','Brick slip adhesive mortars',#5518,$,$); -#5520=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_10','Cement gauged designed mortars',#5518,$,$); -#5521=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_11','Cement gauged mortars',#5518,$,$); -#5522=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_12','Cementitious and reaction resin grouts',#5518,$,$); -#5523=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_13','Cementitious grouts',#5518,$,$); -#5524=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_14','Cementitious tanking mortars',#5518,$,$); -#5525=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_15','Concrete repair mortars',#5518,$,$); -#5526=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_16','Cementitious tiling grouts',#5518,$,$); -#5527=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_18','Crystallization active slurry mortars',#5518,$,$); -#5528=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_26','Epoxy mortars',#5518,$,$); -#5529=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_27','Epoxy resin grouts',#5518,$,$); -#5530=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_28','Epoxy resin-modified cementitious slurries',#5518,$,$); -#5531=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_30','Fibre-reinforced polymer-modified cementitious mortars',#5518,$,$); -#5532=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_31','Fire-resisting mortars',#5518,$,$); -#5533=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_32','General purpose cement:sand mortars',#5518,$,$); -#5534=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_33','Glass block jointing mortars',#5518,$,$); -#5535=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_34','Glass block pointing mortars',#5518,$,$); -#5536=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_39','Hydraulic lime mortars',#5518,$,$); -#5537=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_40','Injection grouts',#5518,$,$); -#5538=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_41','Injection mortar damp proof courses',#5518,$,$); -#5539=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_42','Injection mortars',#5518,$,$); -#5540=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_43','Intumescent mortars',#5518,$,$); -#5541=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_47','Lightweight masonry mortars',#5518,$,$); -#5542=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_50','Masonry grout',#5518,$,$); -#5543=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_52','Metal anchor and fixings grouts',#5518,$,$); -#5544=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_54','Mortar repair mortar',#5518,$,$); -#5545=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_60','Paving jointing mortars',#5518,$,$); -#5546=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_61','Paving laying course mortars',#5518,$,$); -#5547=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_62','Paving unit priming slurry mortars',#5518,$,$); -#5548=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_64','Polyester resin grouts',#5518,$,$); -#5549=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_65','Polymer-modified cementitious mortars',#5518,$,$); -#5550=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_66','Polymer-modified cementitious slurries',#5518,$,$); -#5551=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_71','Resin grouts',#5518,$,$); -#5552=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_76','Self-hardening slurry mixes',#5518,$,$); -#5553=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_79','Silica grouts',#5518,$,$); -#5554=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_88','Thin-layer mortars',#5518,$,$); -#5555=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_90','Thixotropic resin grouts',#5518,$,$); -#5556=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_96','Waterproof mortars',#5518,$,$); -#5557=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_56','Natural resins',#5340,$,$); -#5558=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_56_11','Balsam resins',#5557,$,$); -#5559=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_56_13','Benzoin resins',#5557,$,$); -#5560=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_56_16','Copal resins',#5557,$,$); -#5561=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_56_21','Damar resins',#5557,$,$); -#5562=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_56_46','Lacquer resins',#5557,$,$); -#5563=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_56_50','Mastic resins',#5557,$,$); -#5564=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_56_77','Shellac resins',#5557,$,$); -#5565=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_56_91','Turpentine resins',#5557,$,$); -#5566=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86','Synthetic resins',#5340,$,$); -#5567=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_01','Acetal resins',#5566,$,$); -#5568=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_02','Acrylic resins',#5566,$,$); -#5569=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_03','Acrylonitrile butadiene styrene (ABS) resins',#5566,$,$); -#5570=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_04','Alkyd resins',#5566,$,$); -#5571=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_27','Epoxy resins',#5566,$,$); -#5572=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_28','Ethylene vinyl acetate (EVA) resins',#5566,$,$); -#5573=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_46','Liquid crystal polymer resins',#5566,$,$); -#5574=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_48','Long-fibre reinforced plastics resins',#5566,$,$); -#5575=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_51','Melamine formaldehyde (MF) resins',#5566,$,$); -#5576=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_58','Phenol formaldehyde (PF) resins',#5566,$,$); -#5577=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_59','Polyamide (PA) resins',#5566,$,$); -#5578=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_60','Polycarbonate resins',#5566,$,$); -#5579=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_61','Polyester resins',#5566,$,$); -#5580=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_62','Polyethylene (PE) resins',#5566,$,$); -#5581=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_63','Polyethylene terephthalate (PET) resins',#5566,$,$); -#5582=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_64','Polyphenylene sulfide resins',#5566,$,$); -#5583=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_65','Polypropylene resins',#5566,$,$); -#5584=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_66','Polystyrene (PS) resins',#5566,$,$); -#5585=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_67','Polyurethane (PU) resins',#5566,$,$); -#5586=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_68','Polyvinyl chloride (PVC) resins',#5566,$,$); -#5587=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_77','Silicone resins',#5566,$,$); -#5588=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_88','Thermoplastic elastomer (TPE) resins',#5566,$,$); -#5589=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_92','Unsaturated polyester (UP) resins',#5566,$,$); -#5590=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_93','Urea formaldehyde (UF) resins',#5566,$,$); -#5591=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_94','Vinyl ester resins',#5566,$,$); -#5592=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65','Prefabricated buildings and structures',#5026,$,$); -#5593=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_34','Glazed structures',#5592,$,$); -#5594=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_34_34','Glazed enclosures',#5593,$,$); -#5595=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_34_51','Metal framed structures',#5593,$,$); -#5596=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_34_72','Roof lanterns',#5593,$,$); -#5597=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_50','Modular products',#5592,$,$); -#5598=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_50_10','Bathroom pods',#5597,$,$); -#5599=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_60','Panelled and framed structures',#5592,$,$); -#5600=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_60_15','Concrete panelled buildings',#5599,$,$); -#5601=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_60_17','Cross laminated timber (CLT) panelled buildings',#5599,$,$); -#5602=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_60_47','Light gauge steel floors and roofs',#5599,$,$); -#5603=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_60_48','Light gauge steel frame walls',#5599,$,$); -#5604=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_60_60','Packaged components',#5599,$,$); -#5605=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_60_84','Structural insulated panels (SIPs)',#5599,$,$); -#5606=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_60_88','Timber frame floors and roofs',#5599,$,$); -#5607=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_60_89','Timber frame panels',#5599,$,$); -#5608=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_78','Shelter structures',#5592,$,$); -#5609=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_78_15','Composite panelled shelters',#5608,$,$); -#5610=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_78_34','Glazed shelters',#5608,$,$); -#5611=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_78_58','Open sided shelters',#5608,$,$); -#5612=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_78_77','Semi closed shelters',#5608,$,$); -#5613=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_78_88','Timber framed and panelled shelters',#5608,$,$); -#5614=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76','Sectional products',#5026,$,$); -#5615=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_06','Balusters and newel posts',#5614,$,$); -#5616=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_06_03','Aluminium balusters and newel posts',#5615,$,$); -#5617=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_06_11','Carbon steel balusters and newel posts',#5615,$,$); -#5618=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_06_12','Cast iron balusters and newel posts',#5615,$,$); -#5619=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_06_16','Concrete balusters and newel posts',#5615,$,$); -#5620=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_06_36','Hardwood balusters and newel posts',#5615,$,$); -#5621=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_06_63','Plastics balusters and newel posts',#5615,$,$); -#5622=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_06_80','Softwood balusters and newel posts',#5615,$,$); -#5623=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_06_83','Stainless steel balusters and newel posts',#5615,$,$); -#5624=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_06_86','Stone balusters and newel posts',#5615,$,$); -#5625=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_06_88','Timber spindles',#5615,$,$); -#5626=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08','Bollards and impact protectors',#5614,$,$); -#5627=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_02','Aluminium alloy bollards',#5626,$,$); -#5628=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_03','Aluminium alloy hinged bollards',#5626,$,$); -#5629=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_04','Aluminium alloy telescopic bollards',#5626,$,$); -#5630=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_10','Carbon steel bollards',#5626,$,$); -#5631=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_11','Carbon steel hinged bollards',#5626,$,$); -#5632=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_12','Carbon steel rising bollards',#5626,$,$); -#5633=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_13','Carbon steel telescopic bollards',#5626,$,$); -#5634=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_14','Cast iron bollards',#5626,$,$); -#5635=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_15','Collapsible metal bollards',#5626,$,$); -#5636=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_16','Collapsible polymer bollards',#5626,$,$); -#5637=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_17','Collapsible timber bollards',#5626,$,$); -#5638=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_18','Composite bollards',#5626,$,$); -#5639=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_19','Concrete bollards',#5626,$,$); -#5640=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_36','Hardwood bollards',#5626,$,$); -#5641=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_51','Metal bollards',#5626,$,$); -#5642=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_52','Metal impact protectors',#5626,$,$); -#5643=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_53','Metal impact protectors with infill',#5626,$,$); -#5644=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_60','Panel fenders',#5626,$,$); -#5645=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_62','Plastics bollards',#5626,$,$); -#5646=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_63','Plastics hinged car bollards',#5626,$,$); -#5647=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_64','Plastics rising bollards',#5626,$,$); -#5648=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_65','Plastics telescopic bollards',#5626,$,$); -#5649=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_66','Polymer bollards',#5626,$,$); -#5650=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_67','Precast concrete bollards',#5626,$,$); -#5651=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_71','Retracting metal bollards',#5626,$,$); -#5652=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_82','Stainless steel bollards',#5626,$,$); -#5653=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_83','Stainless steel hinged bollards',#5626,$,$); -#5654=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_84','Stainless steel rising bollards',#5626,$,$); -#5655=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_85','Stainless steel telescopic bollards',#5626,$,$); -#5656=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_86','Stone bollards',#5626,$,$); -#5657=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_88','Timber bollards',#5626,$,$); -#5658=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51','Metal sections',#5614,$,$); -#5659=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_01','Aluminium cold drawn bars and rods',#5658,$,$); -#5660=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_02','Aluminium curtain wall frame sections',#5658,$,$); -#5661=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_03','Aluminium extruded bars and rods',#5658,$,$); -#5662=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_04','Aluminium extruded precision profiles',#5658,$,$); -#5663=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_05','Aluminium patent glazing bars',#5658,$,$); -#5664=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_07','Aluminium structural sections',#5658,$,$); -#5665=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_08','Box sections',#5658,$,$); -#5666=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_09','Brass sections',#5658,$,$); -#5667=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_10','Bronze sections',#5658,$,$); -#5668=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_11','Carbon steel bars',#5658,$,$); -#5669=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_12','Carbon steel beams, columns, channels and tees',#5658,$,$); -#5670=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_13','Carbon steel channels',#5658,$,$); -#5671=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_14','Carbon steel curtain wall frame sections',#5658,$,$); -#5672=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_15','Carbon steel curved sections',#5658,$,$); -#5673=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_17','Carbon steel pales',#5658,$,$); -#5674=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_18','Carbon steel patent glazing bars',#5658,$,$); -#5675=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_19','Carbon steel tees',#5658,$,$); -#5676=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_20','Cast iron products',#5658,$,$); -#5677=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_21','Cold-formed galvanized steel sections',#5658,$,$); -#5678=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_22','Cold-formed steel strip studs',#5658,$,$); -#5679=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_23','Copper alloy sections',#5658,$,$); -#5680=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_25','Curtain wall blast-resistant frame sections',#5658,$,$); -#5681=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_51','Metal mullions and transoms',#5658,$,$); -#5682=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_73','Resilient bars',#5658,$,$); -#5683=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_77','Sheathed carbon steel patent glazing bars',#5658,$,$); -#5684=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_81','Stainless steel bars and rods for construction',#5658,$,$); -#5685=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_82','Stainless steel bars and rods for general purposes',#5658,$,$); -#5686=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_83','Stainless steel sheet, strip and plate for construction',#5658,$,$); -#5687=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_84','Stainless steel sheet, strip and plate for general purposes',#5658,$,$); -#5688=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_85','Stainless steel pales',#5658,$,$); -#5689=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_90','Universal beam sections',#5658,$,$); -#5690=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_92','Universal column sections',#5658,$,$); -#5691=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_98','Wrought iron sections',#5658,$,$); -#5692=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_52','Metal tubes and hollow sections',#5614,$,$); -#5693=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_52_01','Aluminium cold drawn tubes',#5692,$,$); -#5694=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_52_03','Aluminium extruded tubes',#5692,$,$); -#5695=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_52_16','Carbon steel hot-finished hollow sections',#5692,$,$); -#5696=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_52_19','Carbon steel seamless tubes',#5692,$,$); -#5697=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_52_20','Carbon steel welded tubes',#5692,$,$); -#5698=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_52_85','Stainless steel seamless circular tubes',#5692,$,$); -#5699=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_52_86','Stainless steel welded circular tubes',#5692,$,$); -#5700=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_63','Plastics sections',#5614,$,$); -#5701=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_63_30','Flexible foam rods',#5700,$,$); -#5702=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_63_63','Plastics mullions and transoms',#5700,$,$); -#5703=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_63_65','Plastics palisades',#5700,$,$); -#5704=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_63_85','Structural plastics sections',#5700,$,$); -#5705=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_63_92','Unplasticized polyvinyl chloride (PVC-U) curtain wall frame sections',#5700,$,$); -#5706=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64','Posts and post accessories',#5614,$,$); -#5707=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_01','Adjustable post bases',#5706,$,$); -#5708=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_03','Aluminium alloy posts',#5706,$,$); -#5709=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_04','Aluminium post tops',#5706,$,$); -#5710=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_10','Carbon steel electric security fencing posts',#5706,$,$); -#5711=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_11','Carbon steel extension arms',#5706,$,$); -#5712=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_12','Carbon steel posts',#5706,$,$); -#5713=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_13','Carbon steel post tops',#5706,$,$); -#5714=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_14','Carbon steel wind posts',#5706,$,$); -#5715=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_15','Cast iron posts',#5706,$,$); -#5716=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_16','Cast iron post tops',#5706,$,$); -#5717=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_17','Cast stone or concrete posts',#5706,$,$); -#5718=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_18','Cast stone or concrete post tops',#5706,$,$); -#5719=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_19','Concrete extension arms',#5706,$,$); -#5720=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_20','Concrete posts',#5706,$,$); -#5721=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_21','Concrete post tops',#5706,$,$); -#5722=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_36','Hardwood posts',#5706,$,$); -#5723=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_37','Hardwood post tops',#5706,$,$); -#5724=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_51','Metal electric security fencing posts',#5706,$,$); -#5725=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_52','Metal extension arms',#5706,$,$); -#5726=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_53','Metal posts',#5706,$,$); -#5727=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_54','Metal post bases',#5706,$,$); -#5728=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_55','Metal post tops',#5706,$,$); -#5729=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_62','Plastics posts',#5706,$,$); -#5730=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_63','Plastics post tops',#5706,$,$); -#5731=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_65','Polymer posts',#5706,$,$); -#5732=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_66','Polymer post tops',#5706,$,$); -#5733=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_77','Softwood posts',#5706,$,$); -#5734=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_78','Softwood post tops',#5706,$,$); -#5735=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_80','Stainless steel posts',#5706,$,$); -#5736=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_81','Stainless steel post tops',#5706,$,$); -#5737=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_82','Stainless steel wind posts',#5706,$,$); -#5738=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_83','Stand-off post bases',#5706,$,$); -#5739=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_87','Timber hand posts',#5706,$,$); -#5740=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_88','Timber posts',#5706,$,$); -#5741=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_89','Timber post tops',#5706,$,$); -#5742=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_95','Wood hand posts',#5706,$,$); -#5743=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_96','Wood panel supports',#5706,$,$); -#5744=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70','Rail track and ancillaries',#5614,$,$); -#5745=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_09','Bullhead rails',#5744,$,$); -#5746=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_12','Check rails',#5744,$,$); -#5747=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_15','Conductor rails',#5744,$,$); -#5748=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_22','Derailment containment',#5744,$,$); -#5749=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_27','Equipment protection ramps',#5744,$,$); -#5750=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_28','Expansion switches and adjustment switches',#5744,$,$); -#5751=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_30','Flat bottom rails',#5744,$,$); -#5752=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_34','Grooved rails',#5744,$,$); -#5753=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_60','Particle magnets',#5744,$,$); -#5754=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_67','Rail dampers',#5744,$,$); -#5755=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_69','Rail groove drains',#5744,$,$); -#5756=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_70','Rail track tie bars',#5744,$,$); -#5757=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_71','Rail section convertors',#5744,$,$); -#5758=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_80','Slipper runs',#5744,$,$); -#5759=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_90','Transition rails',#5744,$,$); -#5760=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71','Railway junction works',#5614,$,$); -#5761=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_15','Common crossings',#5760,$,$); -#5762=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_17','Crossovers',#5760,$,$); -#5763=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_21','Derailers',#5760,$,$); -#5764=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_23','Diamond crossings',#5760,$,$); -#5765=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_50','Moveable rail crossings',#5760,$,$); -#5766=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_58','Obtuse crossings',#5760,$,$); -#5767=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_76','Scissor crossovers',#5760,$,$); -#5768=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_78','Slips',#5760,$,$); -#5769=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_79','Switch rollers',#5760,$,$); -#5770=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_80','Stretcher bars',#5760,$,$); -#5771=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_81','Stretcher bar brackets',#5760,$,$); -#5772=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_82','Stretcher drive brackets',#5760,$,$); -#5773=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_83','Swing nose crossings',#5760,$,$); -#5774=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_84','Switch and stock rails',#5760,$,$); -#5775=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_85','Switch diamonds',#5760,$,$); -#5776=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_86','Switch supplementary drives',#5760,$,$); -#5777=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_87','Tandem turnouts',#5760,$,$); -#5778=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_90','Trap switches',#5760,$,$); -#5779=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_91','Turnouts',#5760,$,$); -#5780=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_78','Shaft structure products',#5614,$,$); -#5781=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_78_12','Concrete caisson rings',#5780,$,$); -#5782=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_78_14','Concrete shaft cover slabs',#5780,$,$); -#5783=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_78_16','Concrete shaft landing slabs',#5780,$,$); -#5784=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_78_65','Precast concrete shaft units',#5780,$,$); -#5785=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88','Timber sections',#5614,$,$); -#5786=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_14','Cleft chestnut pales',#5785,$,$); -#5787=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_32','Hardwood capping and counter fencing rails',#5785,$,$); -#5788=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_33','Hardwood components for fencing and barriers',#5785,$,$); -#5789=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_34','Hardwood fencing rails',#5785,$,$); -#5790=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_35','Hardwood floating floor battens',#5785,$,$); -#5791=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_36','Hardwood gravity battens',#5785,$,$); -#5792=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_37','Hardwood log poles',#5785,$,$); -#5793=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_40','Hardwood pales',#5785,$,$); -#5794=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_41','Hardwood partition studs',#5785,$,$); -#5795=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_42','Hardwood rafters',#5785,$,$); -#5796=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_43','Hardwood roofing and cladding battens',#5785,$,$); -#5797=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_44','Hardwood sections',#5785,$,$); -#5798=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_46','Hardwood weatherboarding battens',#5785,$,$); -#5799=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_48','Laminated strand lumber (LSL) sections',#5785,$,$); -#5800=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_49','Laminated veneer lumber (LVL) sections',#5785,$,$); -#5801=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_60','Parallel strand lumber (PSL) sections',#5785,$,$); -#5802=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_72','Softwood capping and counter fencing rails',#5785,$,$); -#5803=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_73','Softwood components for fencing and barriers',#5785,$,$); -#5804=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_74','Softwood fencing rails',#5785,$,$); -#5805=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_75','Softwood floating floor battens',#5785,$,$); -#5806=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_76','Softwood gravity battens',#5785,$,$); -#5807=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_79','Softwood pales',#5785,$,$); -#5808=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_80','Softwood partition studs',#5785,$,$); -#5809=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_81','Softwood rafters',#5785,$,$); -#5810=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_82','Softwood roofing and cladding battens',#5785,$,$); -#5811=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_83','Softwood sections',#5785,$,$); -#5812=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_84','Softwood weatherboarding battens',#5785,$,$); -#5813=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_85','Timber beams, bearers, noggings, walings, wedges and packs',#5785,$,$); -#5814=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_86','Timber fencing battens',#5785,$,$); -#5815=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_87','Timber partition battens',#5785,$,$); -#5816=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_88','Timber pales',#5785,$,$); -#5817=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_89','Timber mullions and transoms',#5785,$,$); -#5818=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_92','Tunnel structure products',#5614,$,$); -#5819=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_92_65','Precast concrete tunnel units',#5818,$,$); -#5820=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85','Support and restraint products',#5026,$,$); -#5821=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_03','Angles',#5820,$,$); -#5822=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_03_02','Aluminium angles',#5821,$,$); -#5823=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_03_11','Carbon steel angle sections',#5821,$,$); -#5824=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_03_50','Masonry angle supports',#5821,$,$); -#5825=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_03_63','Plain angle supports',#5821,$,$); -#5826=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_03_84','Stainless steel angles',#5821,$,$); -#5827=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_03_85','Stainless steel cladding angles',#5821,$,$); -#5828=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_06','Bands and hoops',#5820,$,$); -#5829=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_06_06','Bandings',#5828,$,$); -#5830=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_06_11','Carbon steel hoops',#5828,$,$); -#5831=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_06_85','Stainless steel hoops',#5828,$,$); -#5832=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07','Barrier rails',#5820,$,$); -#5833=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_02','Aluminium alloy rails',#5832,$,$); -#5834=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_03','Aluminium support rails',#5832,$,$); -#5835=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_04','Aluminium carrier rails',#5832,$,$); -#5836=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_10','Carbon steel carrier rails',#5832,$,$); -#5837=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_11','Carbon steel fencing and barrier rails',#5832,$,$); -#5838=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_12','Carbon steel fencing and barrier top rails',#5832,$,$); -#5839=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_13','Carbon steel safety barrier open box beams',#5832,$,$); -#5840=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_14','Carbon steel safety barrier rectangular hollow sections',#5832,$,$); -#5841=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_15','Carbon steel safety barrier tensioned corrugated beams',#5832,$,$); -#5842=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_16','Carbon steel safety barrier transitions and connections',#5832,$,$); -#5843=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_17','Carbon steel safety barrier un-tensioned corrugated beams',#5832,$,$); -#5844=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_18','Carbon steel support rails',#5832,$,$); -#5845=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_19','Cast iron rails',#5832,$,$); -#5846=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_20','Concrete rails',#5832,$,$); -#5847=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_63','Plastics rails',#5832,$,$); -#5848=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_65','Protective frames',#5832,$,$); -#5849=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_83','Stainless steel carrier rails',#5832,$,$); -#5850=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_84','Stainless steel rails',#5832,$,$); -#5851=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_85','Stainless steel support rails',#5832,$,$); -#5852=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_92','Unplasticized polyvinyl chloride (PVC-U) support rails',#5832,$,$); -#5853=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_97','Wall-mounted furniture support rails',#5832,$,$); -#5854=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08','Beams and joists',#5820,$,$); -#5855=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_02','Aluminium structural beams',#5854,$,$); -#5856=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_11','Carbon steel beams',#5854,$,$); -#5857=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_12','Castellated carbon steel beams',#5854,$,$); -#5858=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_15','Concrete beams',#5854,$,$); -#5859=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_17','Cross laminated timber beams',#5854,$,$); -#5860=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_33','Glued laminated timber beams',#5854,$,$); -#5861=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_36','Hardwood beams',#5854,$,$); -#5862=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_63','Plastics beams',#5854,$,$); -#5863=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_65','Post-tensioned concrete beams',#5854,$,$); -#5864=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_66','Prestressed concrete T-beams',#5854,$,$); -#5865=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_81','Softwood beams',#5854,$,$); -#5866=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_83','Stainless steel structural beams',#5854,$,$); -#5867=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_84','Structural wood-composite box beams',#5854,$,$); -#5868=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_85','Structural wood-composite I-beams',#5854,$,$); -#5869=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_86','Structural wood-composite I-joists',#5854,$,$); -#5870=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_87','Structural wood composites',#5854,$,$); -#5871=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09','Brackets',#5820,$,$); -#5872=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_01','Above-ground drainage pipe brackets',#5871,$,$); -#5873=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_02','Aluminium brackets',#5871,$,$); -#5874=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_03','Aluminium bronze brackets',#5871,$,$); -#5875=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_05','Aluminium downpipe brackets',#5871,$,$); -#5876=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_07','Aluminium rainwater gutter brackets',#5871,$,$); -#5877=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_09','Bracketed angle supports',#5871,$,$); -#5878=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_11','Carbon steel brackets',#5871,$,$); -#5879=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_12','Carbon steel cavity barrier brackets',#5871,$,$); -#5880=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_14','Carbon steel fencing brackets',#5871,$,$); -#5881=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_16','Carbon steel masonry brackets',#5871,$,$); -#5882=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_17','Cast and wrought iron brackets',#5871,$,$); -#5883=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_18','Cast iron downpipe brackets',#5871,$,$); -#5884=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_19','Cast iron rainwater gutter brackets',#5871,$,$); -#5885=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_20','Copper brackets',#5871,$,$); -#5886=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_21','Copper downpipe brackets',#5871,$,$); -#5887=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_22','Copper rainwater gutter brackets',#5871,$,$); -#5888=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_23','Curtain wall adjustable support brackets',#5871,$,$); -#5889=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_24','Downpipe brackets',#5871,$,$); -#5890=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_26','Eaves gutter brackets',#5871,$,$); -#5891=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_28','Extinguisher mounting brackets',#5871,$,$); -#5892=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_30','Fire bucket wall brackets',#5871,$,$); -#5893=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_31','Galvanized steel downpipe brackets',#5871,$,$); -#5894=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_32','Galvanized steel rainwater gutter brackets',#5871,$,$); -#5895=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_33','Galvanized steel brackets',#5871,$,$); -#5896=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_37','Hollow box galvanized steel brackets',#5871,$,$); -#5897=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_38','Hot-dip pre-coated carbon steel downpipe brackets',#5871,$,$); -#5898=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_39','Hot-dip pre-coated carbon steel rainwater gutter brackets',#5871,$,$); -#5899=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_42','Individual masonry brackets',#5871,$,$); -#5900=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_46','Ladder gutter brackets',#5871,$,$); -#5901=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_47','Ladder wall brackets',#5871,$,$); -#5902=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_48','Louvre and shading mounting brackets',#5871,$,$); -#5903=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_52','Metal timber member fixing brackets',#5871,$,$); -#5904=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_54','Mounting brackets',#5871,$,$); -#5905=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_62','Phosphor bronze brackets',#5871,$,$); -#5906=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_63','Plastics brackets',#5871,$,$); -#5907=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_72','Roof gutter brackets',#5871,$,$); -#5908=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_81','Stainless steel brackets',#5871,$,$); -#5909=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_82','Stainless steel cavity barrier brackets',#5871,$,$); -#5910=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_84','Stainless steel handrail brackets',#5871,$,$); -#5911=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_87','Stainless steel masonry brackets',#5871,$,$); -#5912=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_88','Sink supports',#5871,$,$); -#5913=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_92','Unplasticized polyvinyl chloride (PVC-U) downpipe brackets',#5871,$,$); -#5914=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_93','Unplasticized polyvinyl chloride (PVC-U) rainwater gutter brackets',#5871,$,$); -#5915=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_96','Wall-hung WC support brackets',#5871,$,$); -#5916=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_98','Wash basin support brackets',#5871,$,$); -#5917=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_10','Bridge bearings',#5820,$,$); -#5918=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_10_20','Cylindrical PTFE bearings',#5917,$,$); -#5919=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_10_27','Elastomeric bearings',#5917,$,$); -#5920=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_10_35','Guide bearings',#5917,$,$); -#5921=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_10_65','Pot bearings',#5917,$,$); -#5922=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_10_70','Restraint bearings',#5917,$,$); -#5923=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_10_72','Rocker bearings',#5917,$,$); -#5924=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_10_73','Roller bearings',#5917,$,$); -#5925=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_10_79','Sliding element',#5917,$,$); -#5926=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_10_81','Spherical PTFE bearings',#5917,$,$); -#5927=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_11','Bridge suspension cables',#5820,$,$); -#5928=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_11_48','Locked coil strand cables',#5927,$,$); -#5929=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_11_60','Parallel wire strand cables',#5927,$,$); -#5930=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_11_80','Spiral strand cables',#5927,$,$); -#5931=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_12','Bunds and ducts',#5820,$,$); -#5932=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_12_14','Concrete bund units',#5931,$,$); -#5933=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_12_24','Concrete duct units',#5931,$,$); -#5934=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_13','Concrete base and foundation products',#5820,$,$); -#5935=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_13_29','Concrete bases for fence posts',#5934,$,$); -#5936=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_13_30','Concrete floating slab foundations',#5934,$,$); -#5937=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_13_32','Concrete foundation pads',#5934,$,$); -#5938=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_13_35','Concrete ground beams',#5934,$,$); -#5939=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_13_63','Concrete plinth units',#5934,$,$); -#5940=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_13_65','Concrete pocket foundations',#5934,$,$); -#5941=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_14','Concrete flooring and decking products',#5820,$,$); -#5942=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_14_14','Concrete hollow core slabs',#5941,$,$); -#5943=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_14_15','Concrete kentledge blocks',#5941,$,$); -#5944=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_14_16','Concrete solid slabs',#5941,$,$); -#5945=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_16','Columns and column accessories',#5820,$,$); -#5946=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_16_02','Aluminium structural columns',#5945,$,$); -#5947=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_16_03','Aluminium column shoes',#5945,$,$); -#5948=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_16_11','Carbon steel columns',#5945,$,$); -#5949=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_16_12','Carbon steel column shoes',#5945,$,$); -#5950=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_16_15','Concrete columns',#5945,$,$); -#5951=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_16_36','Hardwood structural columns',#5945,$,$); -#5952=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_16_62','Plastics columns',#5945,$,$); -#5953=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_16_81','Softwood structural columns',#5945,$,$); -#5954=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_16_84','Stainless steel structural columns',#5945,$,$); -#5955=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_16_85','Stainless steel column shoes',#5945,$,$); -#5956=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_16_86','Stone columns',#5945,$,$); -#5957=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_16_96','Wind posts',#5945,$,$); -#5958=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_18','Bridge deck products',#5820,$,$); -#5959=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_18_10','Bridge diaphragms',#5958,$,$); -#5960=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_18_12','Cast iron bridge pedestals',#5958,$,$); -#5961=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_18_14','Concrete bridge pedestals',#5958,$,$); -#5962=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_18_85','Steel bridge pedestals',#5958,$,$); -#5963=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28','Erosion control and breakwater products',#5820,$,$); -#5964=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_09','Brushwood fascines',#5963,$,$); -#5965=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_15','Coir erosion mats',#5963,$,$); -#5966=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_16','Concrete tetrapods',#5963,$,$); -#5967=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_27','Erosion control logs',#5963,$,$); -#5968=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_28','Erosion control pallets',#5963,$,$); -#5969=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_30','Flood barriers',#5963,$,$); -#5970=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_33','Galvanized wire bastion cages',#5963,$,$); -#5971=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_34','Galvanized wire mattress cages',#5963,$,$); -#5972=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_35','Galvanized wire trapion cages',#5963,$,$); -#5973=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_36','Galvanized wire gabion cages',#5963,$,$); -#5974=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_38','Hessian bags',#5963,$,$); -#5975=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_45','Liquid-absorbing barriers',#5963,$,$); -#5976=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_46','Liquid-absorbing sacks',#5963,$,$); -#5977=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_62','Plastics mattress cages',#5963,$,$); -#5978=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_63','Polypropylene bags',#5963,$,$); -#5979=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_64','Polypropylene (PP) rock rolls',#5963,$,$); -#5980=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_75','Sand bags',#5963,$,$); -#5981=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32','Frames and grids',#5820,$,$); -#5982=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_01','Aluminium-zinc coated retention grids',#5981,$,$); -#5983=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_02','Aluminium frames',#5981,$,$); -#5984=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_04','Aluminium structural sealant glazing sub-frames',#5981,$,$); -#5985=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_06','Aluminium sub-frames',#5981,$,$); -#5986=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_11','Carbon steel frames',#5981,$,$); -#5987=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_12','Carbon steel frame fasteners',#5981,$,$); -#5988=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_13','Carbon steel structural sealant glazing sub-frames',#5981,$,$); -#5989=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_14','Carbon steel dry lining frames',#5981,$,$); -#5990=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_16','Carbon steel sub-frames',#5981,$,$); -#5991=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_22','Demountable suspended ceiling grids',#5981,$,$); -#5992=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_30','Floor level chute support frames',#5981,$,$); -#5993=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_80','Solar module ballasted mounting frames',#5981,$,$); -#5994=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_81','Solar module free-standing mounting frames',#5981,$,$); -#5995=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_82','Space frames',#5981,$,$); -#5996=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_84','Stainless steel frames',#5981,$,$); -#5997=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_85','Stainless steel frame fasteners',#5981,$,$); -#5998=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_88','Timber dry lining frames',#5981,$,$); -#5999=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_92','Unplasticized polyvinyl chloride (PVC-U) frames',#5981,$,$); -#6000=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_93','Unplasticized polyvinyl chloride (PVC-U) sub-frames',#5981,$,$); -#6001=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_94','Unplasticized polyvinyl chloride (PVC-U) window sub-frames',#5981,$,$); -#6002=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_96','Wood frames',#5981,$,$); -#6003=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_97','Wood sub-frames',#5981,$,$); -#6004=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_98','Wood window sub-frames',#5981,$,$); -#6005=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_34','Ground support products',#5820,$,$); -#6006=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_34_34','Grouted pipe spiles',#6005,$,$); -#6007=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_34_84','Steel spiles',#6005,$,$); -#6008=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_46','Lathings and furrings',#5820,$,$); -#6009=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_46_21','Damp proof lathings',#6008,$,$); -#6010=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_46_28','Expanded metal lathings',#6008,$,$); -#6011=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_46_36','Hardwood furrings',#6008,$,$); -#6012=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_46_52','Metal arch form lathings',#6008,$,$); -#6013=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_46_53','Metal furring channels',#6008,$,$); -#6014=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_46_96','Wood lathings',#6008,$,$); -#6015=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_46_97','Wood tapered furring pieces',#6008,$,$); -#6016=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_47','Legs, pedestals, hangers and stringers',#5820,$,$); -#6017=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_47_01','Access floor bridging sections',#6016,$,$); -#6018=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_47_02','Access floor pedestals',#6016,$,$); -#6019=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_47_03','Access floor stringers',#6016,$,$); -#6020=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_47_04','Acoustic batten cradles',#6016,$,$); -#6021=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_47_20','Cubicle and partition legs',#6016,$,$); -#6022=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_47_22','Decking and paving pedestals',#6016,$,$); -#6023=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_47_47','Leg supports',#6016,$,$); -#6024=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_47_49','Metal J hangers',#6016,$,$); -#6025=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_47_50','Metal hanging rails',#6016,$,$); -#6026=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_47_51','Metal suspended ceiling hangers',#6016,$,$); -#6027=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_47_84','Stair stringers',#6016,$,$); -#6028=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_47_88','Timber dowel hanging rails',#6016,$,$); -#6029=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_48','Lintels',#5820,$,$); -#6030=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_48_02','Aggregate concrete trough lintels',#6029,$,$); -#6031=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_48_11','Carbon steel lintels',#6029,$,$); -#6032=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_48_13','Clay block trough lintels',#6029,$,$); -#6033=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_48_15','Concrete lintels',#6029,$,$); -#6034=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_48_33','Glass-reinforced concrete (GRC) built-in lintel heads',#6029,$,$); -#6035=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_48_34','Glass-reinforced concrete (GRC) dressing lintel heads',#6029,$,$); -#6036=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_48_43','Inset open fireplace throat-forming lintels and corbel units',#6029,$,$); -#6037=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_48_50','Manufactured stone lintels',#6029,$,$); -#6038=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_48_56','Natural stone lintels',#6029,$,$); -#6039=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_48_67','Prestressed concrete lintels',#6029,$,$); -#6040=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_48_84','Stainless steel lintels',#6029,$,$); -#6041=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_48_88','Timber lintels',#6029,$,$); -#6042=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_50','Masts and poles',#5820,$,$); -#6043=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_50_01','Aeronautical ground lighting masts',#6042,$,$); -#6044=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_50_04','Antenna poles',#6042,$,$); -#6045=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_50_50','Metal windsock masts',#6042,$,$); -#6046=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_50_64','Plastics windsock masts',#6042,$,$); -#6047=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_50_85','Surveillance camera masts',#6042,$,$); -#6048=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_50_90','Traffic signal poles',#6042,$,$); -#6049=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62','Piles and ancillary products',#5820,$,$); -#6050=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_10','Carbon steel displacement piles',#6049,$,$); -#6051=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_11','Carbon steel pile casings',#6049,$,$); -#6052=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_12','Carbon steel pile shoes',#6049,$,$); -#6053=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_13','Carbon steel screw piles',#6049,$,$); -#6054=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_14','Carbon steel sheet piles',#6049,$,$); -#6055=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_15','Cast steel pile shoes',#6049,$,$); -#6056=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_16','Composite steel sheet piles',#6049,$,$); -#6057=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_17','Concrete cantilevered knuckle piles',#6049,$,$); -#6058=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_18','Concrete piles',#6049,$,$); -#6059=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_19','Concrete pile caps',#6049,$,$); -#6060=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_23','Concrete sheet piles',#6049,$,$); -#6061=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_36','Hardwood piles',#6049,$,$); -#6062=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_64','Plastics drainage weep holes',#6049,$,$); -#6063=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_65','Plastics screw piles',#6049,$,$); -#6064=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_66','Plastics sheet piles',#6049,$,$); -#6065=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_77','Sheet pile wall corner connectors',#6049,$,$); -#6066=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_80','Softwood piles',#6049,$,$); -#6067=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_65','Platform products',#5820,$,$); -#6068=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_65_11','Concrete platform copings',#6067,$,$); -#6069=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_65_13','Concrete platform sections',#6067,$,$); -#6070=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_65_15','Concrete platform slabs',#6067,$,$); -#6071=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_65_17','Concrete platform units',#6067,$,$); -#6072=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_65_34','Glass reinforced plastics (GRP) modular platform panel',#6067,$,$); -#6073=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70','Rail supports and fixings',#5820,$,$); -#6074=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_08','Bullhead rail chairs',#6073,$,$); -#6075=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_10','Cast blocks and spacers assemblies',#6073,$,$); -#6076=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_12','Check rail baseplates',#6073,$,$); -#6077=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_13','Check rail resilient baseplates',#6073,$,$); -#6078=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_24','Driven spikes',#6073,$,$); -#6079=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_30','Ferrules and bushes',#6073,$,$); -#6080=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_44','Junction work baseplates',#6073,$,$); -#6081=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_45','Junction work crossing plates',#6073,$,$); -#6082=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_46','Junction work heel baseplates',#6073,$,$); -#6083=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_47','Junction work resilient baseplates',#6073,$,$); -#6084=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_48','Junction work resilient slide plates',#6073,$,$); -#6085=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_49','Junction work slide plates',#6073,$,$); -#6086=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_54','Metal spacers assemblies',#6073,$,$); -#6087=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_63','Plain line resilient baseplates',#6073,$,$); -#6088=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_64','Plain line baseplates',#6073,$,$); -#6089=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_65','Plastics rail embedments',#6073,$,$); -#6090=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_70','Rail boots',#6073,$,$); -#6091=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_71','Rail clip and shoulder assemblies',#6073,$,$); -#6092=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_74','Rubber chamber filling elements',#6073,$,$); -#6093=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_76','Screw spikes',#6073,$,$); -#6094=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_80','Soleplates',#6073,$,$); -#6095=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_82','Spring spikes',#6073,$,$); -#6096=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_71','Rail rings',#5820,$,$); -#6097=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_71_11','Carbon steel rings',#6096,$,$); -#6098=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_71_12','Cast iron bolted rings',#6096,$,$); -#6099=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_71_13','Cast iron expanded rings',#6096,$,$); -#6100=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_71_15','Concrete bolted rings',#6096,$,$); -#6101=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_71_16','Concrete expanded rings',#6096,$,$); -#6102=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_71_57','Nodular iron rings',#6096,$,$); -#6103=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_72','Rail sleepers and bearers',#5820,$,$); -#6104=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_72_17','Composite bearers',#6103,$,$); -#6105=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_72_18','Composite sleepers',#6103,$,$); -#6106=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_72_20','Concrete bearers',#6103,$,$); -#6107=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_72_21','Concrete monoblock sleepers',#6103,$,$); -#6108=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_72_22','Concrete twinblock sleepers',#6103,$,$); -#6109=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_72_47','Longitudinal bearers',#6103,$,$); -#6110=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_72_50','Modular bearer tie plates',#6103,$,$); -#6111=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_72_77','Single block rail support',#6103,$,$); -#6112=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_72_80','Sleeper anchors',#6103,$,$); -#6113=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_72_85','Steel sleepers',#6103,$,$); -#6114=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_72_88','Timber bearers',#6103,$,$); -#6115=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_72_89','Timber sleepers',#6103,$,$); -#6116=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_74','Rail pads and shims',#5820,$,$); -#6117=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_74_06','Baseplate shims',#6116,$,$); -#6118=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_74_27','Ethyl vinyl acetate rail pads',#6116,$,$); -#6119=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_74_70','Rail packing shims',#6116,$,$); -#6120=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_74_71','Rail pads',#6116,$,$); -#6121=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_74_73','Resilient baseplate pads',#6116,$,$); -#6122=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_74_74','Resilient bearer pads',#6116,$,$); -#6123=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_74_76','Resilient sleeper pads',#6116,$,$); -#6124=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_74_78','Rubber bonded cork rail pads',#6116,$,$); -#6125=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_74_79','Rubber rail pads',#6116,$,$); -#6126=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_76','Shock absorbers',#5820,$,$); -#6127=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_76_09','Bridge shock absorbers',#6126,$,$); -#6128=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_76_76','Seismic dampers',#6126,$,$); -#6129=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84','Straps, ties, channels and inserts',#5820,$,$); -#6130=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_02','Aluminium bronze slot ties',#6129,$,$); -#6131=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_04','Aluminium bronze wall head restraint slip ties',#6129,$,$); -#6132=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_11','Carbon steel cast-in channels',#6129,$,$); -#6133=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_12','Carbon steel movement joint lateral restraint slip ties',#6129,$,$); -#6134=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_13','Carbon steel lateral restraint straps',#6129,$,$); -#6135=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_14','Carbon steel slot ties',#6129,$,$); -#6136=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_15','Carbon steel threaded studding ties',#6129,$,$); -#6137=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_16','Carbon steel tie bars',#6129,$,$); -#6138=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_17','Carbon steel vertical restraint straps',#6129,$,$); -#6139=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_18','Carbon steel wall head restraint slip ties',#6129,$,$); -#6140=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_19','Cavity wall ties',#6129,$,$); -#6141=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_20','Channel slot ties',#6129,$,$); -#6142=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_21','Copper slot ties',#6129,$,$); -#6143=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_22','Copper wall head restraint slip ties',#6129,$,$); -#6144=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_28','Existing wall tie isolating sleeves',#6129,$,$); -#6145=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_33','General-purpose slip ties',#6129,$,$); -#6146=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_36','Head restraint slip ties',#6129,$,$); -#6147=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_46','Lateral restraint ties',#6129,$,$); -#6148=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_50','Masonry repair ties',#6129,$,$); -#6149=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_57','Non-loadbearing wall head restraints',#6129,$,$); -#6150=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_61','Permanent insulation formwork (PIF) connectors',#6129,$,$); -#6151=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_62','Phosphor bronze slot ties',#6129,$,$); -#6152=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_63','Phosphor bronze wall head restraint slip ties',#6129,$,$); -#6153=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_64','Polyester (PET) straps',#6129,$,$); -#6154=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_68','Retaining wall tie rods',#6129,$,$); -#6155=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_69','Restraint belts',#6129,$,$); -#6156=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_70','Roof gutter straps',#6129,$,$); -#6157=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_73','Shear wall ties',#6129,$,$); -#6158=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_74','Slotted wall channels and brackets',#6129,$,$); -#6159=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_75','Stainless steel lateral restraint straps',#6129,$,$); -#6160=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_76','Stainless steel slot ties',#6129,$,$); -#6161=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_77','Stainless steel threaded studding ties',#6129,$,$); -#6162=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_78','Stainless steel tie bars',#6129,$,$); -#6163=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_79','Stainless steel vertical restraint straps',#6129,$,$); -#6164=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_80','Stainless steel wall head restraint slip ties',#6129,$,$); -#6165=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_81','Stainless steel drive ties',#6129,$,$); -#6166=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_82','Stainless steel resin-bonded ties',#6129,$,$); -#6167=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_83','Stainless steel expansion ties',#6129,$,$); -#6168=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_84','Stainless steel cast-in channels',#6129,$,$); -#6169=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_85','Stainless steel cladding channels',#6129,$,$); -#6170=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_86','Stainless steel cladding ties',#6129,$,$); -#6171=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_87','Surface mounted channels',#6129,$,$); -#6172=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_88','Tension or compression bracing products',#6129,$,$); -#6173=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_89','Tension straps',#6129,$,$); -#6174=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_95','Wall starters and connectors',#6129,$,$); -#6175=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_97','Water-resistant concrete formwork ties',#6129,$,$); -#6176=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_85','Structural bearings',#5820,$,$); -#6177=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_85_02','Acoustic and vibration resistant bearings',#6176,$,$); -#6178=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_85_06','Bearing strips and mats',#6176,$,$); -#6179=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_85_11','Carbon steel stools',#6176,$,$); -#6180=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_85_30','Flat jacks',#6176,$,$); -#6181=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_85_36','Hard packing',#6176,$,$); -#6182=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_85_60','Padstones',#6176,$,$); -#6183=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_85_74','Rubber bearings',#6176,$,$); -#6184=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_85_80','Sliding surface bearings',#6176,$,$); -#6185=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_85_84','Stainless steel stools',#6176,$,$); -#6186=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_86','Struts and props',#5820,$,$); -#6187=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_86_11','Carbon steel struts',#6186,$,$); -#6188=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_86_30','Formwork props',#6186,$,$); -#6189=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_86_31','Formwork shores',#6186,$,$); -#6190=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_86_76','Screw jacks',#6186,$,$); -#6191=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_86_84','Stainless steel struts',#6186,$,$); -#6192=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_86_89','Trench boxes or shields',#6186,$,$); -#6193=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_86_90','Trench shores',#6186,$,$); -#6194=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_86_91','Trench struts',#6186,$,$); -#6195=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_88','Track beds',#5820,$,$); -#6196=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_88_06','Ballast mats',#6195,$,$); -#6197=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_88_07','Ballast track beds',#6195,$,$); -#6198=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_88_17','Concrete track beds',#6195,$,$); -#6199=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_89','Train arrestors',#5820,$,$); -#6200=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_89_30','Fixed train arrestors',#6199,$,$); -#6201=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_89_31','Friction train arrestors',#6199,$,$); -#6202=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_89_39','Hydraulic train arrestors',#6199,$,$); -#6203=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_90','Trusses and lattice frames',#5820,$,$); -#6204=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_90_02','Aluminium lattice trusses and frames',#6203,$,$); -#6205=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_90_11','Carbon steel lattice floor joists and purlins',#6203,$,$); -#6206=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_90_12','Carbon steel pitched roof trusses',#6203,$,$); -#6207=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_90_36','Hardwood lattice joists',#6203,$,$); -#6208=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_90_37','Hardwood trussed rafters',#6203,$,$); -#6209=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_90_38','Hardwood trusses',#6203,$,$); -#6210=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_90_81','Softwood trusses',#6203,$,$); -#6211=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_90_82','Softwood trussed rafters',#6203,$,$); -#6212=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_90_84','Steel lattice frames',#6203,$,$); -#6213=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93','Unit structure and general products',#5026,$,$); -#6214=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_33','Glass blocks and panels',#6213,$,$); -#6215=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_33_12','Cellular glass thermal blocks',#6214,$,$); -#6216=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_33_30','Fire rated glass block wall panels',#6214,$,$); -#6217=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_33_31','Glass block dry joint spacers',#6214,$,$); -#6218=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_33_32','Glass block mortar joint spacers',#6214,$,$); -#6219=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_33_33','Glass block wall panels',#6214,$,$); -#6220=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_33_34','Glass blocks',#6214,$,$); -#6221=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_33_52','Mortar jointed glass block wall panels',#6214,$,$); -#6222=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_33_53','Mortar jointed and sealant pointed glass block wall panels',#6214,$,$); -#6223=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_33_76','Sealant jointed glass block wall panels',#6214,$,$); -#6224=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_37','Headwall and swale inlet products',#6213,$,$); -#6225=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_37_62','Plastics headwall units',#6224,$,$); -#6226=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_37_63','Plastics swale inlets',#6224,$,$); -#6227=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_37_65','Precast concrete headwall units',#6224,$,$); -#6228=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_37_66','Precast concrete swale inlets',#6224,$,$); -#6229=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_51','Masonry flooring units',#6213,$,$); -#6230=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_51_02','Aggregate concrete infill blocks',#6229,$,$); -#6231=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_51_05','Autoclaved aerated concrete (AAC) infill blocks',#6229,$,$); -#6232=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_51_28','Expanded polystyrene (EPS) infill blocks',#6229,$,$); -#6233=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52','Masonry walling units',#6213,$,$); -#6234=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_01','Aggregate concrete blocks',#6233,$,$); -#6235=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_02','Aggregate concrete bricks',#6233,$,$); -#6236=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_05','Autoclaved aerated concrete (AAC) blocks',#6233,$,$); -#6237=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_11','Calcium silicate blocks',#6233,$,$); -#6238=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_12','Calcium silicate bricks',#6233,$,$); -#6239=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_13','Cast stone masonry units',#6233,$,$); -#6240=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_14','Clay blocks',#6233,$,$); -#6241=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_15','Clay bricks',#6233,$,$); -#6242=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_23','Dimensioned stones',#6233,$,$); -#6243=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_27','Engineering bricks',#6233,$,$); -#6244=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_33','Glass-reinforced concrete (GRC) blocks',#6233,$,$); -#6245=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_34','Glazed clay bricks',#6233,$,$); -#6246=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_35','Glazed concrete blocks',#6233,$,$); -#6247=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_36','Gypsum blocks',#6233,$,$); -#6248=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_42','Insulated concrete blocks',#6233,$,$); -#6249=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_50','Manufactured stone blocks',#6233,$,$); -#6250=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_56','Natural dimensioned stones',#6233,$,$); -#6251=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_57','Natural rubble stones',#6233,$,$); -#6252=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_58','Natural stone plugs',#6233,$,$); -#6253=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_71','Reclaimed clay bricks',#6233,$,$); -#6254=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_73','Refractory bricks',#6233,$,$); -#6255=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_74','Replacement natural dimensioned stones',#6233,$,$); -#6256=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_75','Salvaged natural stones',#6233,$,$); -#6257=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_87','Terracotta units',#6233,$,$); -#6258=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_89','Thin joint autoclaved aerated concrete (AAC) blocks',#6233,$,$); -#6259=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_71','Retaining wall units',#6213,$,$); -#6260=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_71_11','Carbon steel spreader plates',#6259,$,$); -#6261=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_71_15','Concrete interlocking blocks',#6259,$,$); -#6262=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_71_16','Concrete crib wall units',#6259,$,$); -#6263=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_71_17','Concrete panels',#6259,$,$); -#6264=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_71_18','Concrete diaphragm wall units',#6259,$,$); -#6265=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_71_53','Modular reinforced concrete stem wall units',#6259,$,$); -#6266=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_71_65','Preformed stop ends',#6259,$,$); -#6267=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_71_75','Sawn hardwood crib wall units',#6259,$,$); -#6268=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_76','Shaft-lining products',#6213,$,$); -#6269=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_76_11','Carbon steel shaft-lining segments',#6268,$,$); -#6270=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_76_12','Cast iron shaft-lining segments',#6268,$,$); -#6271=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_76_15','Concrete shaft-lining segments',#6268,$,$); -#6272=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_76_80','Spheroidal graphite iron (SGI) shaft-lining segments',#6268,$,$); -#6273=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_84','Structural roofing units',#6213,$,$); -#6274=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_84_15','Concrete arch units',#6273,$,$); -#6275=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_84_16','Concrete dome units',#6273,$,$); -#6276=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_84_84','Structural insulated roof panels',#6273,$,$); -#6277=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_85','Structural walling units',#6213,$,$); -#6278=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_85_14','Concrete solid wall and composite wall units',#6277,$,$); -#6279=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_85_16','Concrete structural insulated panels (SIPs)',#6277,$,$); -#6280=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_85_84','Structural insulated wall panels',#6277,$,$); -#6281=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_85_88','Timber-framed straw-filled panels',#6277,$,$); -#6282=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_90','Tunnel-lining products',#6213,$,$); -#6283=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_90_11','Carbon steel tunnel-lining segments',#6282,$,$); -#6284=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_90_12','Cast iron tunnel-lining segments',#6282,$,$); -#6285=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_90_15','Concrete tunnel-lining segments',#6282,$,$); -#6286=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_90_80','Spheroidal graphite iron (SGI) tunnel-lining segments',#6282,$,$); -#6287=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_90_90','Tunnel segment connectors',#6282,$,$); -#6288=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_95','Tunnel opening products',#6213,$,$); -#6289=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_95_15','Tunnel frame cills',#6288,$,$); -#6290=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_95_44','Tunnel frame jambs',#6288,$,$); -#6291=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_95_47','Tunnel frame lintels',#6288,$,$); -#6292=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96','Wire structure and general products',#5026,$,$); -#6293=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71','Reinforcement',#6292,$,$); -#6294=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_10','Carbon steel bed joint reinforcement',#6293,$,$); -#6295=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_11','Carbon steel cage reinforcement',#6293,$,$); -#6296=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_12','Carbon steel fabric reinforcement',#6293,$,$); -#6297=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_13','Carbon steel plain bar reinforcement',#6293,$,$); -#6298=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_14','Carbon steel ribbed bar reinforcement',#6293,$,$); -#6299=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_15','Carbon steel post-installed starter bars',#6293,$,$); -#6300=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_16','Carbon steel tendons',#6293,$,$); -#6301=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_17','Copper rod reinforcement',#6293,$,$); -#6302=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_28','Fibre reinforced plastics bar reinforcement',#6293,$,$); -#6303=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_30','Fibrous reinforcement',#6293,$,$); -#6304=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_33','Glass fibre fleece reinforcement',#6293,$,$); -#6305=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_34','Glass fibre mesh reinforcement',#6293,$,$); -#6306=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_35','Glass fibre reinforcement mats',#6293,$,$); -#6307=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_36','Glass fibre reinforcement tendons',#6293,$,$); -#6308=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_51','Mechanical reinforcement couplers',#6293,$,$); -#6309=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_52','Meshwork joint reinforcement',#6293,$,$); -#6310=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_62','Phosphor bronze rod reinforcement',#6293,$,$); -#6311=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_64','Polyester (PES) fibre fleece reinforcement',#6293,$,$); -#6312=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_66','Prefabricated continuity reinforcement strips',#6293,$,$); -#6313=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_67','Prefabricated reinforcement',#6293,$,$); -#6314=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_83','Stainless steel bed joint reinforcement',#6293,$,$); -#6315=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_84','Stainless steel fabric reinforcement',#6293,$,$); -#6316=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_85','Stainless steel plain bar reinforcement',#6293,$,$); -#6317=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_86','Stainless steel ribbed bar reinforcement',#6293,$,$); -#6318=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_87','Stainless steel post-installed starter bars',#6293,$,$); -#6319=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_97','Welded wire mesh reinforcement',#6293,$,$); -#6320=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_96','Wire fencing ancillary products',#6292,$,$); -#6321=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_96_11','Carbon steel fencing cleats',#6320,$,$); -#6322=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_96_12','Carbon steel fencing droppers',#6320,$,$); -#6323=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_96_13','Carbon steel fencing rings',#6320,$,$); -#6324=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_96_14','Carbon steel fencing strainers',#6320,$,$); -#6325=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_96_15','Carbon steel fencing stretcher bars',#6320,$,$); -#6326=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_96_16','Carbon steel fencing wedges',#6320,$,$); -#6327=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_96_17','Carbon steel pre-formed fencing lashing rods',#6320,$,$); -#6328=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_96_72','Rotating vane fence toppings',#6320,$,$); -#6329=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97','Wires, ropes, twines and chains',#6292,$,$); -#6330=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_02','Aluminium wires',#6329,$,$); -#6331=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_11','Carbon steel barbed tapes',#6329,$,$); -#6332=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_12','Carbon steel barbed wires',#6329,$,$); -#6333=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_13','Carbon steel chains',#6329,$,$); -#6334=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_14','Carbon steel high tensile barbed wires',#6329,$,$); -#6335=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_15','Carbon steel high tensile line wires',#6329,$,$); -#6336=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_16','Carbon steel razor wires',#6329,$,$); -#6337=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_17','Carbon steel spring wires',#6329,$,$); -#6338=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_18','Carbon steel wire ropes',#6329,$,$); -#6339=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_19','Carbon steel wires',#6329,$,$); -#6340=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_21','Copper alloy wires',#6329,$,$); -#6341=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_27','Electric fence ropes',#6329,$,$); -#6342=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_51','Mixed fibre ropes',#6329,$,$); -#6343=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_56','Natural ropes',#6329,$,$); -#6344=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_57','Natural threads',#6329,$,$); -#6345=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_58','Natural twines',#6329,$,$); -#6346=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_60','Phosphor bronze wires',#6329,$,$); -#6347=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_62','Plastics chains',#6329,$,$); -#6348=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_63','Plastics wires or lines',#6329,$,$); -#6349=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_73','Shock-absorbing lanyards',#6329,$,$); -#6350=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_74','Stainless steel barbed tapes',#6329,$,$); -#6351=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_75','Stainless steel barbed wires',#6329,$,$); -#6352=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_76','Stainless steel chains',#6329,$,$); -#6353=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_77','Stainless steel high tensile barbed wires',#6329,$,$); -#6354=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_78','Stainless steel high tensile line wires',#6329,$,$); -#6355=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_79','Stainless steel razor wires',#6329,$,$); -#6356=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_80','Stainless steel spring wires',#6329,$,$); -#6357=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_81','Stainless steel wire ropes',#6329,$,$); -#6358=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_82','Stainless steel wires',#6329,$,$); -#6359=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_83','Swimming pool flagged ropes',#6329,$,$); -#6360=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_84','Swimming pool false start ropes',#6329,$,$); -#6361=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_85','Swimming pool lane ropes',#6329,$,$); -#6362=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_86','Synthetic chains',#6329,$,$); -#6363=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_87','Synthetic ropes',#6329,$,$); -#6364=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_88','Synthetic threads',#6329,$,$); -#6365=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_89','Synthetic twines',#6329,$,$); -#6366=IFCCLASSIFICATIONREFERENCE($,'Pr_25','Skin products',#4921,$,$); -#6367=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30','Fixed access products',#6366,$,$); -#6368=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30','Floor plates, gratings and edgings',#6367,$,$); -#6369=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_01','Aluminium cold formed planks',#6368,$,$); -#6370=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_02','Aluminium duckboards',#6368,$,$); -#6371=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_03','Aluminium edging sections',#6368,$,$); -#6372=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_04','Aluminium expanded gratings',#6368,$,$); -#6373=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_05','Aluminium open bar metal gratings',#6368,$,$); -#6374=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_06','Aluminium solid metal plates',#6368,$,$); -#6375=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_12','Carbon steel cold formed planks',#6368,$,$); -#6376=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_14','Carbon steel edging sections',#6368,$,$); -#6377=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_16','Carbon steel expanded gratings',#6368,$,$); -#6378=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_18','Carbon steel open bar metal gratings',#6368,$,$); -#6379=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_20','Carbon steel solid metal plates',#6368,$,$); -#6380=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_22','Concrete planks',#6368,$,$); -#6381=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_34','Glass-reinforced plastics (GRP) moulded open mesh gratings',#6368,$,$); -#6382=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_36','Hardwood duckboards',#6368,$,$); -#6383=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_58','Open bar glass-reinforced plastics (GRP) gratings',#6368,$,$); -#6384=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_63','Plastics perforated gratings',#6368,$,$); -#6385=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_80','Softwood duckboards',#6368,$,$); -#6386=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_81','Solid glass-reinforced plastics (GRP) plates',#6368,$,$); -#6387=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_82','Stainless steel cold formed planks',#6368,$,$); -#6388=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_83','Stainless steel edging sections',#6368,$,$); -#6389=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_84','Stainless steel expanded gratings',#6368,$,$); -#6390=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_85','Stainless steel open bar metal gratings',#6368,$,$); -#6391=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_86','Stainless steel solid metal plates',#6368,$,$); -#6392=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_36','Handrails',#6367,$,$); -#6393=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_36_03','Aluminium handrails',#6392,$,$); -#6394=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_36_11','Carbon steel handrails',#6392,$,$); -#6395=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_36_30','Fibre-reinforced polymer handrails',#6392,$,$); -#6396=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_36_34','Grab rails',#6392,$,$); -#6397=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_36_50','Manufactured stone handrails',#6392,$,$); -#6398=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_36_63','Plastics handrails',#6392,$,$); -#6399=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_36_84','Stainless steel handrails',#6392,$,$); -#6400=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_36_96','Wood handrails',#6392,$,$); -#6401=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_75','Safety cages',#6367,$,$); -#6402=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_75_02','Aluminium ladder safety cages',#6401,$,$); -#6403=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_75_15','Carbon steel ladder safety cages',#6401,$,$); -#6404=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_75_80','Stainless steel ladder safety cages',#6401,$,$); -#6405=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85','Stair and ladder units',#6367,$,$); -#6406=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_02','Access ladders',#6405,$,$); -#6407=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_03','Aluminium loft ladders',#6405,$,$); -#6408=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_11','Cat ladders',#6405,$,$); -#6409=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_16','Curved internal staircases',#6405,$,$); -#6410=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_22','Drainage access chamber ladders',#6405,$,$); -#6411=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_23','Drainage access chamber steps',#6405,$,$); -#6412=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_36','Hardwood loft ladders',#6405,$,$); -#6413=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_48','Lift pit ladders',#6405,$,$); -#6414=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_64','Pool ladders',#6405,$,$); -#6415=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_65','Pool stepladders',#6405,$,$); -#6416=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_73','Roll-up ladders',#6405,$,$); -#6417=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_79','Sliding ladders',#6405,$,$); -#6418=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_83','Steel loft ladders',#6405,$,$); -#6419=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_84','Spiral internal staircases',#6405,$,$); -#6420=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_85','Step-over ladders',#6405,$,$); -#6421=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_86','Straight internal staircases',#6405,$,$); -#6422=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_90','Travelling ladders',#6405,$,$); -#6423=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86','Surface level traffic control products',#6367,$,$); -#6424=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_03','Aluminium alloy vehicle flow plates',#6423,$,$); -#6425=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_04','Aluminium alloy vehicle stops',#6423,$,$); -#6426=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_11','Carbon steel vehicle flow plates',#6423,$,$); -#6427=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_12','Carbon steel vehicle stops',#6423,$,$); -#6428=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_15','Concrete demarcation units',#6423,$,$); -#6429=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_60','Pavement extenders',#6423,$,$); -#6430=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_72','Rising kerbs',#6423,$,$); -#6431=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_73','Rising ramp vehicle barriers',#6423,$,$); -#6432=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_74','Rising spike vehicle stops',#6423,$,$); -#6433=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_75','Rubber vehicle stops',#6423,$,$); -#6434=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_83','Speed restriction ramps',#6423,$,$); -#6435=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_88','Timber vehicle stops',#6423,$,$); -#6436=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_90','Traffic calming speed cushions',#6423,$,$); -#6437=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_91','Traffic islands',#6423,$,$); -#6438=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90','Treads and landing units',#6367,$,$); -#6439=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_10','Carbon steel stair treads',#6438,$,$); -#6440=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_11','Concrete glazed stair treads',#6438,$,$); -#6441=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_12','Concrete glazed stair landing panels',#6438,$,$); -#6442=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_13','Concrete helical stair flight units',#6438,$,$); -#6443=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_14','Concrete spiral stair flight units',#6438,$,$); -#6444=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_15','Concrete stair flight and landing units',#6438,$,$); -#6445=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_16','Concrete stair flight units',#6438,$,$); -#6446=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_17','Concrete stair landing units',#6438,$,$); -#6447=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_18','Concrete step units',#6438,$,$); -#6448=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_33','Glass stair treads',#6438,$,$); -#6449=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_36','Hardwood stair treads',#6438,$,$); -#6450=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_63','Plastics stair treads',#6438,$,$); -#6451=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_81','Softwood stair treads',#6438,$,$); -#6452=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_83','Stainless steel stair treads',#6438,$,$); -#6453=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_84','Stone stair treads',#6438,$,$); -#6454=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_85','Stone step units',#6438,$,$); -#6455=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31','Formless skin products',#6366,$,$); -#6456=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_28','Expanding foams',#6455,$,$); -#6457=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_28_65','Polyisocyanurate (PIR) foam insulation',#6456,$,$); -#6458=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_28_66','Polyurethane (PUR) injected foam insulation',#6456,$,$); -#6459=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_28_67','Polyurethane (PUR) foam insulation',#6456,$,$); -#6460=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_28_93','Urea-formaldehyde foam (UFF) insulation',#6456,$,$); -#6461=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_28_94','Vermin and insect-proof expanding foams',#6456,$,$); -#6462=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_48','Loose insulation',#6455,$,$); -#6463=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_48_12','Cellulose fibre loose insulation',#6462,$,$); -#6464=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_48_27','Expanded cork loose insulation',#6462,$,$); -#6465=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_48_28','Expanded polystyrene (EPS) bead insulation',#6462,$,$); -#6466=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_48_34','Granular mineral wool insulation',#6462,$,$); -#6467=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_48_48','Loose-fill mineral wool fibre insulation',#6462,$,$); -#6468=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_48_61','Perlite loose insulation',#6462,$,$); -#6469=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_48_66','Polyurethane (PUR) foam chip insulation',#6462,$,$); -#6470=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_48_71','Recycled paper loose insulation',#6462,$,$); -#6471=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_48_76','Sea grass loose insulation',#6462,$,$); -#6472=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_48_94','Vermiculite loose insulation',#6462,$,$); -#6473=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57','Non-rigid sheet, mat and strip skin products',#6366,$,$); -#6474=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06','Batt and quilt products',#6473,$,$); -#6475=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_02','Aerogel blanket insulation',#6474,$,$); -#6476=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_15','Cotton fibre batt insulation',#6474,$,$); -#6477=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_28','Felt backing insulation',#6474,$,$); -#6478=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_30','Flexible glass wool mat insulation',#6474,$,$); -#6479=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_31','Flexible rock wool mat insulation',#6474,$,$); -#6480=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_32','Formed recycled paper insulation',#6474,$,$); -#6481=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_34','Glass fibre insulation',#6474,$,$); -#6482=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_37','Hemp fibre insulation',#6474,$,$); -#6483=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_47','Lift car protective quilts',#6474,$,$); -#6484=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_50','Mineral fibre slab insulation',#6474,$,$); -#6485=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_52','Mineral wool flexible insulation',#6474,$,$); -#6486=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_53','Mineral wool insulation',#6474,$,$); -#6487=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_54','Mineral wool resilient layer sound insulation',#6474,$,$); -#6488=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_55','Mineral wool resilient strip sound insulation',#6474,$,$); -#6489=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_56','Mineral wool slab insulation',#6474,$,$); -#6490=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_57','Multifoil blanket insulation',#6474,$,$); -#6491=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_70','Reflective foil insulation',#6474,$,$); -#6492=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_71','Resilient layer insulation',#6474,$,$); -#6493=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_76','Sheep wool insulation',#6474,$,$); -#6494=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_94','Vacuum insulated panels',#6474,$,$); -#6495=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_97','Wood fibre batt insulation',#6474,$,$); -#6496=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_08','Bitumen-based membranes, sheets and fabrics',#6473,$,$); -#6497=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_08_08','Bitumen sheets',#6496,$,$); -#6498=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_08_58','Pitch polymer membranes',#6496,$,$); -#6499=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_08_71','Reinforced bitumen membrane perforated underlays',#6496,$,$); -#6500=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_08_75','Reinforced bitumen roofing sheets',#6496,$,$); -#6501=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_10','Building papers and vapour permeable sheets',#6473,$,$); -#6502=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_10_04','Aluminium foil/ kraft paper laminates',#6501,$,$); -#6503=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_10_08','Bitumen bonded kraft papers',#6501,$,$); -#6504=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_10_09','Building papers',#6501,$,$); -#6505=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_10_12','Cellulose based building papers',#6501,$,$); -#6506=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_10_37','High density polyethylene (PE-HD) vapour permeable sheets',#6501,$,$); -#6507=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_10_45','Kraft papers',#6501,$,$); -#6508=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_10_47','Low density polyethylene (PE-LD) vapour permeable sheets',#6501,$,$); -#6509=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_10_62','Polyethylene coated kraft papers',#6501,$,$); -#6510=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_10_64','Polyolefin vapour permeable sheets',#6501,$,$); -#6511=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_10_66','Polypropylene vapour permeable sheets',#6501,$,$); -#6512=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_10_68','Polypropylene and polyethylene laminate vapour permeable sheets',#6501,$,$); -#6513=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_10_94','Vapour permeable sheets',#6501,$,$); -#6514=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21','Damp proof courses and cavity trays',#6473,$,$); -#6515=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_02','Aluminium damp proof courses and cavity trays',#6514,$,$); -#6516=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_06','Bitumen-based damp proof courses and cavity trays',#6514,$,$); -#6517=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_08','Bitumen polymer damp proof courses and cavity trays',#6514,$,$); -#6518=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_11','Carbon steel damp proof courses and cavity trays',#6514,$,$); -#6519=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_12','Cavity closer and damp proof course supports',#6514,$,$); -#6520=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_13','Clay brick damp proof courses',#6514,$,$); -#6521=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_14','Cold-applied roofing membrane adhesive damp proof course joint sealers',#6514,$,$); -#6522=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_16','Coping or capping damp proof courses',#6514,$,$); -#6523=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_18','Copper damp proof courses and cavity trays',#6514,$,$); -#6524=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_27','Ethylene propylene (EP) damp proof courses and cavity trays',#6514,$,$); -#6525=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_33','Gas resistant preformed cavity trays',#6514,$,$); -#6526=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_34','Gas resistant preformed cavity trays and cloaks',#6514,$,$); -#6527=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_35','Gas-resistant damp proof courses',#6514,$,$); -#6528=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_36','Granite damp proof courses',#6514,$,$); -#6529=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_42','Insertion cavity trays',#6514,$,$); -#6530=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_43','Insulated damp proof courses',#6514,$,$); -#6531=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_44','Joist seals',#6514,$,$); -#6532=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_48','Lead damp proof courses and cavity trays',#6514,$,$); -#6533=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_50','Mastic asphalt (MA) damp proof courses',#6514,$,$); -#6534=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_61','Pitch polymer damp proof courses and cavity trays',#6514,$,$); -#6535=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_63','Polyethylene (PE) damp proof courses and cavity trays',#6514,$,$); -#6536=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_64','Polypropylene (PP) damp proof courses and cavity trays',#6514,$,$); -#6537=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_65','Polymeric damp proof courses',#6514,$,$); -#6538=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_66','Preformed cavity trays',#6514,$,$); -#6539=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_67','Preformed cavity trays and cloaks',#6514,$,$); -#6540=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_68','Preformed damp proof courses',#6514,$,$); -#6541=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_72','Rising damp remedial units',#6514,$,$); -#6542=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_80','Slate damp proof courses',#6514,$,$); -#6543=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_99','Zinc damp proof courses',#6514,$,$); -#6544=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51','Membranes, liners, flexible sheets and fabrics',#6473,$,$); -#6545=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_02','Acrylonitrile butadiene styrene (ABS) studded membranes',#6544,$,$); -#6546=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_10','Butyl rubber (polyisobutylene isoprene (IIR)) geomembranes',#6544,$,$); -#6547=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_11','Carborundum slip-resistant paper',#6544,$,$); -#6548=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_13','Chlorinated polyethylene (PE-C) geomembranes',#6544,$,$); -#6549=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_14','Chlorosulfonated polyethylene (PE-CS) geomembranes',#6544,$,$); -#6550=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_16','Coated polyester fabrics',#6544,$,$); -#6551=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_27','Ethylene propylene diene monomer (EPDM) geomembranes',#6544,$,$); -#6552=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_30','Flexible pond liners',#6544,$,$); -#6553=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_31','Flexible polyolefin (FPO) polymeric membranes',#6544,$,$); -#6554=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_33','Glass fibre fleeces',#6544,$,$); -#6555=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_35','Glass-reinforced plastics (GRP) sheet liners',#6544,$,$); -#6556=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_36','High-density polyethylene (PE-HD) studded sheets',#6544,$,$); -#6557=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_38','High impact polystyrene (HIPS) studded sheets',#6544,$,$); -#6558=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_42','Integrated flexible photovoltaic (PV) module membranes',#6544,$,$); -#6559=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_51','Membrane walkways',#6544,$,$); -#6560=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_52','Metallized plastics window films',#6544,$,$); -#6561=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_54','Modified acrylic fabric',#6544,$,$); -#6562=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_60','Plastics window films',#6544,$,$); -#6563=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_61','Plastics preformed liners',#6544,$,$); -#6564=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_66','Polymeric membranes',#6544,$,$); -#6565=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_67','Polymeric membrane collars',#6544,$,$); -#6566=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_68','Polypropylene (PP) studded sheets',#6544,$,$); -#6567=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_70','Polyvinyl chloride geomembranes',#6544,$,$); -#6568=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_74','Rubber studded sheets',#6544,$,$); -#6569=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_79','Slip-resistant sheets and strips',#6544,$,$); -#6570=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_88','Thermoplastic polyolefin elastomer (TPE) polymeric membranes',#6544,$,$); -#6571=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_95','Vinyl ethylene terpolymer (VET) polymeric membranes',#6544,$,$); -#6572=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_53','Moisture retention sheets',#6473,$,$); -#6573=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_53_30','Foamed aminoplastic resin moisture retention mats',#6572,$,$); -#6574=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_53_50','Mineral wool water retention geotextiles',#6572,$,$); -#6575=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_53_62','Polyacrylonitrile (PAN) water retention geotextiles',#6572,$,$); -#6576=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_53_63','Polyamide water retention geotextiles',#6572,$,$); -#6577=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_53_65','Polypropylene water retention geotextiles',#6572,$,$); -#6578=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56','Netting and non-reinforcement mesh',#6473,$,$); -#6579=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_07','Bird deterrent nets',#6578,$,$); -#6580=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_14','Cleft chestnut palisade rolls',#6578,$,$); -#6581=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_15','Continuous chain link metal mesh',#6578,$,$); -#6582=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_16','Coarse woven plastics mesh',#6578,$,$); -#6583=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_27','Expanded metal mesh',#6578,$,$); -#6584=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_28','Extruded plastics mesh',#6578,$,$); -#6585=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_29','Fine woven plastics mesh',#6578,$,$); -#6586=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_34','Glass fibre mesh',#6578,$,$); -#6587=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_52','Metallic nets',#6578,$,$); -#6588=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_56','Natural nets',#6578,$,$); -#6589=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_61','Perforated metal mesh',#6578,$,$); -#6590=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_64','Plastics nets',#6578,$,$); -#6591=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_85','Spun-bonded plastics mesh',#6578,$,$); -#6592=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_95','Welded metal mesh',#6578,$,$); -#6593=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_96','Wire netting',#6578,$,$); -#6594=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_97','Woven metal mesh',#6578,$,$); -#6595=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_61','Plant-fibre based membranes, liners, flexible sheet and fabrics',#6473,$,$); -#6596=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_61_15','Coir geotextiles',#6595,$,$); -#6597=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_61_29','Flax geotextiles',#6595,$,$); -#6598=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_61_37','Hemp geotextiles',#6595,$,$); -#6599=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_61_44','Jute geotextiles',#6595,$,$); -#6600=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_61_59','Plant and natural fibre linings',#6595,$,$); -#6601=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_61_60','Paper pulp linings',#6595,$,$); -#6602=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_61_79','Sisal membranes',#6595,$,$); -#6603=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_61_80','Sisal jute mix membranes',#6595,$,$); -#6604=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_61_95','Wood fibre membranes',#6595,$,$); -#6605=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_61_97','Wool membranes',#6595,$,$); -#6606=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_61_98','Wool felt membranes',#6595,$,$); -#6607=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_65','Plastics membranes',#6473,$,$); -#6608=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_65_37','High density polyethylene (PE-HD) sheets',#6607,$,$); -#6609=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_65_47','Low density polyethylene (PE-LD) sheets',#6607,$,$); -#6610=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_65_60','Plastics sheets',#6607,$,$); -#6611=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_65_62','Polyester sheets',#6607,$,$); -#6612=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_65_63','Polyethylene sheets',#6607,$,$); -#6613=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_65_65','Polypropylene sheets',#6607,$,$); -#6614=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_65_66','Polypropylene and polyethylene laminate sheets',#6607,$,$); -#6615=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_65_67','Polytetrafluorethylene (PTFE) sheets',#6607,$,$); -#6616=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_65_70','Polyvinylidene fluoride (PVDF) sheets',#6607,$,$); -#6617=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_65_92','Unplasticized polyvinyl chloride (PVC-U) sheets',#6607,$,$); -#6618=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_85','Synthetic filter fabrics',#6473,$,$); -#6619=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_85_10','Capillary fleece',#6618,$,$); -#6620=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_85_62','Polyester fibre fleece',#6618,$,$); -#6621=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_85_64','Polyester filter geotextiles',#6618,$,$); -#6622=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_85_66','Polyethylene filter geotextiles',#6618,$,$); -#6623=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_85_68','Polypropylene filter geotextiles',#6618,$,$); -#6624=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_85_70','Polyvinylidene fluoride (PVDF) hydrophobic geotextiles',#6618,$,$); -#6625=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_90','Tensile, stretch and suspended fabrics',#6473,$,$); -#6626=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_90_03','Aramid tensile fabrics',#6625,$,$); -#6627=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_90_15','Cotton canvas tensile fabrics',#6625,$,$); -#6628=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_90_29','Fabrics for tensile applications',#6625,$,$); -#6629=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_90_34','Glass fibre tensile fabrics',#6625,$,$); -#6630=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_90_63','Polyester tensile fabrics',#6625,$,$); -#6631=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_90_67','Polytetrafluoroethylene (PTFE) tensile fabrics',#6625,$,$); -#6632=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_90_69','Polyurethane coated polyester stretch fabric membranes',#6625,$,$); -#6633=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_90_71','Polyvinyl chloride (PVC) stretch fabric membranes',#6625,$,$); -#6634=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_90_75','Sailcloth',#6625,$,$); -#6635=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_90_81','Solar glass weave tensile fabrics',#6625,$,$); -#6636=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_90_84','Stretch fabric membranes',#6625,$,$); -#6637=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_90_85','Suspended fabric panels',#6625,$,$); -#6638=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71','Rigid board, panel and sheet products',#6366,$,$); -#6639=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14','Cladding and lining panels (lightweight cladding and roofing panels)',#6638,$,$); -#6640=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_01','Aggregate-faced glass reinforced plastics (GRP) panels',#6639,$,$); -#6641=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_02','Aluminium cassette panels',#6639,$,$); -#6642=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_03','Applied facing precast concrete panels',#6639,$,$); -#6643=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_04','Aluminium insulating sandwich panels',#6639,$,$); -#6644=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_05','Aluminium composite material (ACM) panels',#6639,$,$); -#6645=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_06','Aluminium composite panels',#6639,$,$); -#6646=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_07','Aluminium external panels',#6639,$,$); -#6647=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_08','Aluminium infill panels',#6639,$,$); -#6648=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_09','Aluminium internal panels',#6639,$,$); -#6649=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_10','Aluminium-faced aluminium core panels',#6639,$,$); -#6650=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_11','Carbon steel composite panels',#6639,$,$); -#6651=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_12','Carbon steel external panels',#6639,$,$); -#6652=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_13','Carbon steel infill panels',#6639,$,$); -#6653=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_14','Carbon steel internal panels',#6639,$,$); -#6654=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_15','Ceramic panels',#6639,$,$); -#6655=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_16','Column casings',#6639,$,$); -#6656=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_17','Ceramic-faced aluminium core panels',#6639,$,$); -#6657=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_18','Composite and recycled plastics sheets',#6639,$,$); -#6658=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_19','Composite stone panels',#6639,$,$); -#6659=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_20','Compressed rock fibre panels',#6639,$,$); -#6660=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_21','Copper alloy-faced aluminium core panels',#6639,$,$); -#6661=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_22','Carbon steel insulating sandwich panels',#6639,$,$); -#6662=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_30','Fibre cement panels',#6639,$,$); -#6663=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_31','Fireproof casings',#6639,$,$); -#6664=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_33','Glass-faced aluminium core panels',#6639,$,$); -#6665=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_34','Glass reinforced plastics (GRP) panels',#6639,$,$); -#6666=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_52','Monolithic precast concrete cladding panels',#6639,$,$); -#6667=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_56','Natural stone panels',#6639,$,$); -#6668=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_57','Natural stone-faced aluminium core panels',#6639,$,$); -#6669=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_62','Plastics sheet wall claddings',#6639,$,$); -#6670=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_63','Platinum-faced aluminium core panels',#6639,$,$); -#6671=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_65','Pre-weathered zinc cassette panels',#6639,$,$); -#6672=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_71','Reconstituted stone panels',#6639,$,$); -#6673=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_75','Sandwich precast concrete cladding panels',#6639,$,$); -#6674=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_77','Self-finished precast concrete cladding panels',#6639,$,$); -#6675=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_81','Stainless steel-faced aluminium core panels',#6639,$,$); -#6676=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_82','Stainless steel cassette panels',#6639,$,$); -#6677=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_83','Stainless steel composite panels',#6639,$,$); -#6678=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_84','Stainless steel external panels',#6639,$,$); -#6679=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_85','Stainless steel infill panels',#6639,$,$); -#6680=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_86','Stainless steel internal panels',#6639,$,$); -#6681=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_87','Stainless steel insulating sandwich panels',#6639,$,$); -#6682=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_88','Terracotta panels',#6639,$,$); -#6683=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_90','Titanium-faced aluminium core panels',#6639,$,$); -#6684=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_98','Wood fibre-reinforced thermosetting resin external panels',#6639,$,$); -#6685=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_99','Zinc-faced aluminium core panels',#6639,$,$); -#6686=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29','Falsework and formwork',#6638,$,$); -#6687=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_04','Architectural finish permanent formwork linings',#6686,$,$); -#6688=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_11','Carbon steel permanent joint formers',#6686,$,$); -#6689=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_14','Collapsible (wet) board substructure formwork',#6686,$,$); -#6690=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_15','Collapsible board substructure formwork',#6686,$,$); -#6691=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_16','Compressible board substructure formwork',#6686,$,$); -#6692=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_17','Concrete permanent side forms',#6686,$,$); -#6693=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_19','Controlled permeability formwork',#6686,$,$); -#6694=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_24','Duct formers',#6686,$,$); -#6695=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_28','Expanded carbon steel mesh formwork',#6686,$,$); -#6696=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_37','High density expanded polystyrene (HDPS) ventilated substructure formwork',#6686,$,$); -#6697=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_56','Non-critical permanent formwork',#6686,$,$); -#6698=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_60','Permanent concrete composite wall panels',#6686,$,$); -#6699=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_62','Permanent insulation formwork (PIF)',#6686,$,$); -#6700=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_64','Permanent timber formwork',#6686,$,$); -#6701=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_72','Ribbed carbon steel mesh formwork',#6686,$,$); -#6702=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_76','Scaffolding and accessories',#6686,$,$); -#6703=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_86','Suspended in situ concrete construction permanent insulation formwork (PIF)',#6686,$,$); -#6704=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_88','Timber scaffold boards',#6686,$,$); -#6705=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33','Glass and glazing sheets and profiles',#6638,$,$); -#6706=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_02','Annealed glass sheets',#6705,$,$); -#6707=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_03','Antique glass',#6705,$,$); -#6708=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_14','Composite glass sheets',#6705,$,$); -#6709=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_16','Corrugated wired glass sheets',#6705,$,$); -#6710=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_20','Cylinder blown glass sheets',#6705,$,$); -#6711=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_33','Glass beams',#6705,$,$); -#6712=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_34','Glass fins',#6705,$,$); -#6713=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_35','Glass panels',#6705,$,$); -#6714=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_36','Hand blown crown glass',#6705,$,$); -#6715=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_37','Heat strengthened glass sheets',#6705,$,$); -#6716=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_42','Insulated glass units (IGUs)',#6705,$,$); -#6717=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_46','Laminated glass sheets',#6705,$,$); -#6718=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_47','Lead and X-ray glass sheets',#6705,$,$); -#6719=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_65','Plastics glazing sheets',#6705,$,$); -#6720=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_67','Plastics laminated glazing sheets',#6705,$,$); -#6721=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_77','Sealed insulated glass units',#6705,$,$); -#6722=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_84','Stained glass sheets',#6705,$,$); -#6723=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_88','Thermally toughened glass sheets',#6705,$,$); -#6724=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_92','U-profiled glass channels',#6705,$,$); -#6725=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_97','Wired glass sheets',#6705,$,$); -#6726=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_42','Infill panels',#6638,$,$); -#6727=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_42_12','Cement-bonded wood-wool infill panels',#6726,$,$); -#6728=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_42_52','Metal tray infill panels',#6726,$,$); -#6729=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_42_54','Mineral fibre infill panels',#6726,$,$); -#6730=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_42_59','Open-cell infill panels',#6726,$,$); -#6731=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_42_60','Panel diffuser infill panels',#6726,$,$); -#6732=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_42_63','Plastics-faced gypsum plasterboard infill panels',#6726,$,$); -#6733=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_42_70','Raised access floor panels',#6726,$,$); -#6734=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_42_71','Raised access floor panels with finish',#6726,$,$); -#6735=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_42_72','Resin-bonded mineral wool infill panels',#6726,$,$); -#6736=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_42_73','Rigid urethane foam infill panels',#6726,$,$); -#6737=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_42_94','Veneered wood-composite infill panels',#6726,$,$); -#6738=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_43','Interior linings',#6638,$,$); -#6739=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_43_33','Glass-reinforced plastics (GRP) ceilings',#6738,$,$); -#6740=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_43_34','Glass-reinforced plastics (GRP) linings',#6738,$,$); -#6741=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_43_62','Plastics linings',#6738,$,$); -#6742=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_44','Joint fillers',#6638,$,$); -#6743=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_44_06','Bitumen-impregnated softboard joint fillers',#6742,$,$); -#6744=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_44_08','Bitumen rubber expansion joint fillers',#6742,$,$); -#6745=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_44_15','Cork board joint fillers',#6742,$,$); -#6746=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_44_28','Extruded polyethylene (PE) foam joint fillers',#6742,$,$); -#6747=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_44_77','Sealant backer rods',#6742,$,$); -#6748=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50','Metal panels',#6638,$,$); -#6749=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_02','Aluminium expanded mesh panels',#6748,$,$); -#6750=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_03','Aluminium vertical bar panels',#6748,$,$); -#6751=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_04','Aluminium sheet panels',#6748,$,$); -#6752=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_06','Base boards',#6748,$,$); -#6753=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_12','Carbon steel expanded mesh panels',#6748,$,$); -#6754=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_13','Carbon steel framed vertical bar and rail panels',#6748,$,$); -#6755=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_14','Carbon steel framed vertical bar panels',#6748,$,$); -#6756=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_15','Carbon steel framed vertical section panels',#6748,$,$); -#6757=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_16','Carbon steel palisade fence panels',#6748,$,$); -#6758=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_17','Carbon steel panels',#6748,$,$); -#6759=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_18','Carbon steel vertical section and rail panels',#6748,$,$); -#6760=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_19','Carbon steel welded mesh panels',#6748,$,$); -#6761=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_20','Cast iron vertical bar and rail panels',#6748,$,$); -#6762=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_21','Composite fence panels',#6748,$,$); -#6763=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_22','Composite panels',#6748,$,$); -#6764=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_23','Composite wildlife panels',#6748,$,$); -#6765=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_24','Decorative metal panels',#6748,$,$); -#6766=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_39','Hurdles',#6748,$,$); -#6767=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_51','Mesh panels',#6748,$,$); -#6768=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_60','Palisade panels',#6748,$,$); -#6769=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_61','Panels with vertical infill',#6748,$,$); -#6770=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_79','Sheet panels',#6748,$,$); -#6771=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_80','Stainless steel expanded mesh panels',#6748,$,$); -#6772=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_81','Stainless steel vertical bar panels',#6748,$,$); -#6773=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_82','Stainless steel vertical bar and rail panels',#6748,$,$); -#6774=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_83','Stainless steel sheet panels',#6748,$,$); -#6775=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_84','Stainless steel welded mesh panels',#6748,$,$); -#6776=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_85','Stainless steel woven mesh panels',#6748,$,$); -#6777=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_87','Steel noise barrier panels',#6748,$,$); -#6778=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_93','Vitreous enamel steel composite panels',#6748,$,$); -#6779=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_94','Vitreous enamel steel panels',#6748,$,$); -#6780=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_95','Welded steel hurdles',#6748,$,$); -#6781=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_96','Wrought iron decorative panels',#6748,$,$); -#6782=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_97','Wrought iron vertical bar panels',#6748,$,$); -#6783=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_98','Wrought iron vertical bar and rail panels',#6748,$,$); -#6784=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51','Metal sheets and strips',#6638,$,$); -#6785=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_01','Aluminium sheets, strips and plates',#6784,$,$); -#6786=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_02','Aluminium long strips',#6784,$,$); -#6787=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_03','Aluminium profiled sheets',#6784,$,$); -#6788=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_04','Aluminium profiled sheet decking',#6784,$,$); -#6789=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_05','Aluminium sheets',#6784,$,$); -#6790=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_06','Aluminium traditional sheets',#6784,$,$); -#6791=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_10','Carbon steel long strips',#6784,$,$); -#6792=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_11','Carbon steel linings',#6784,$,$); -#6793=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_12','Carbon steel pressed panels',#6784,$,$); -#6794=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_14','Carbon steel sheet walkway reinforcement',#6784,$,$); -#6795=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_15','Carbon steel sheets',#6784,$,$); -#6796=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_16','Copper long strips',#6784,$,$); -#6797=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_17','Copper traditional sheets',#6784,$,$); -#6798=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_33','Galvanized carbon steel profiled sheets',#6784,$,$); -#6799=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_38','Hollow-core metal sheets',#6784,$,$); -#6800=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_46','Lead machine cast sheets',#6784,$,$); -#6801=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_47','Lead rolled sheets',#6784,$,$); -#6802=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_52','Metal profiled sheets',#6784,$,$); -#6803=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_84','Stainless steel long strips and sheets',#6784,$,$); -#6804=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_85','Stainless steel profiled sheets',#6784,$,$); -#6805=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_86','Stainless steel sheets',#6784,$,$); -#6806=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_87','Stainless steel traditional sheets',#6784,$,$); -#6807=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_88','Steel plate, sheet and strip',#6784,$,$); -#6808=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_89','Steel profiled sheet',#6784,$,$); -#6809=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_97','Zinc traditional sheets',#6784,$,$); -#6810=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_98','Zinc soft temper alloy strips',#6784,$,$); -#6811=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_99','Zinc standard temper alloy strips',#6784,$,$); -#6812=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52','Mineral-based boards and sheets',#6638,$,$); -#6813=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_11','Carbon-neutral gypsum plasterboards',#6812,$,$); -#6814=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_12','Carbon steel-faced plasterboard panels',#6812,$,$); -#6815=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_13','Cellular glass insulation boards',#6812,$,$); -#6816=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_15','Compressed mineral wool fire protection boards',#6812,$,$); -#6817=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_17','Compressed vermiculite fire protection boards',#6812,$,$); -#6818=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_21','Enhanced-strength gypsum plasterboards',#6812,$,$); -#6819=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_22','Expanded perlite boards',#6812,$,$); -#6820=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_23','Fibre-reinforced calcium silicate boards',#6812,$,$); -#6821=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_24','Fibre-reinforced calcium silicate fire protection boards',#6812,$,$); -#6822=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_25','Fibre-reinforced cement boards',#6812,$,$); -#6823=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_26','Fibre-reinforced cement profiled sheets',#6812,$,$); -#6824=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_27','Fibre-reinforced cement sheets',#6812,$,$); -#6825=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_28','Fibre-reinforced cement weatherboards',#6812,$,$); -#6826=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_29','Fibre-reinforced gypsum boards',#6812,$,$); -#6827=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_30','Fibre-reinforced gypsum floor boards',#6812,$,$); -#6828=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_31','Fibre-reinforced magnesium silicate boards',#6812,$,$); -#6829=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_32','Flexible plasterboards',#6812,$,$); -#6830=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_33','Fire-resistant gypsum plasterboards',#6812,$,$); -#6831=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_34','Gypsum baseboards',#6812,$,$); -#6832=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_35','Gypsum core boards',#6812,$,$); -#6833=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_36','Gypsum planks',#6812,$,$); -#6834=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_38','Gypsum plasterboards',#6812,$,$); -#6835=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_39','Gypsum plasterboard with combined properties',#6812,$,$); -#6836=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_40','Gypsum sheathing plasterboards',#6812,$,$); -#6837=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_41','Impact-resistant gypsum plasterboards',#6812,$,$); -#6838=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_42','High-density gypsum plasterboards',#6812,$,$); -#6839=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_47','Linoleum composite laminate strips and boards',#6812,$,$); -#6840=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_50','Magnesium oxide boards',#6812,$,$); -#6841=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_52','Moisture-resistant gypsum plasterboards',#6812,$,$); -#6842=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_63','Plasterboard panels',#6812,$,$); -#6843=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_80','Sound insulation gypsum plasterboards',#6812,$,$); -#6844=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_84','Standard gypsum plasterboards',#6812,$,$); -#6845=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_88','Thermal laminate gypsum plasterboards',#6812,$,$); -#6846=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_94','Vapour check gypsum plasterboards',#6812,$,$); -#6847=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_95','Vermiculite-silicate fire protection boards',#6812,$,$); -#6848=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_99','X-ray resistant gypsum plasterboards',#6812,$,$); -#6849=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_53','Mirrors',#6638,$,$); -#6850=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_53_06','Bathroom mirrors',#6849,$,$); -#6851=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_53_30','Framed glass mirrors',#6849,$,$); -#6852=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_53_31','Framed metal mirrors',#6849,$,$); -#6853=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_53_32','Framed plastics mirrors',#6849,$,$); -#6854=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_53_46','Large mirrors',#6849,$,$); -#6855=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_53_65','Platform mirrors',#6849,$,$); -#6856=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_53_70','Rail mirrors',#6849,$,$); -#6857=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_53_73','Road mirrors',#6849,$,$); -#6858=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_53_82','Small mirrors',#6849,$,$); -#6859=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_53_91','Unframed glass mirrors',#6849,$,$); -#6860=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_53_92','Unframed metal mirrors',#6849,$,$); -#6861=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_53_93','Unframed plastics mirrors',#6849,$,$); -#6862=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57','Non-metal barrier panels',#6638,$,$); -#6863=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_11','Cement-bonded particleboard framed panels',#6862,$,$); -#6864=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_12','Concrete base boards',#6862,$,$); -#6865=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_13','Concrete parapet base panels',#6862,$,$); -#6866=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_14','Concrete base panels',#6862,$,$); -#6867=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_15','Concrete fence panel tops',#6862,$,$); -#6868=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_16','Concrete fence panels',#6862,$,$); -#6869=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_17','Concrete containment parapet units',#6862,$,$); -#6870=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_18','Concrete safety barrier panels',#6862,$,$); -#6871=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_19','Concrete noise barrier panels',#6862,$,$); -#6872=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_22','Decorative concrete fence panels',#6862,$,$); -#6873=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_24','Decorative timber panels',#6862,$,$); -#6874=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_34','Glass barrier panels',#6862,$,$); -#6875=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_35','Glazing plastics framed panels',#6862,$,$); -#6876=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_37','Hardwood base boards',#6862,$,$); -#6877=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_38','Hardwood framed panels',#6862,$,$); -#6878=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_39','Hardwood palisade panels',#6862,$,$); -#6879=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_40','Hazel wattle hurdles',#6862,$,$); -#6880=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_44','Jet blast deflectors',#6862,$,$); -#6881=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_60','Partition panels',#6862,$,$); -#6882=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_61','Partition screens',#6862,$,$); -#6883=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_62','Plastics framed panels',#6862,$,$); -#6884=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_63','Plastics panels',#6862,$,$); -#6885=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_64','Plastics panel fence tops',#6862,$,$); -#6886=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_65','Plywood framed panels',#6862,$,$); -#6887=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_66','Polymer based boards',#6862,$,$); -#6888=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_67','Polymer based panels',#6862,$,$); -#6889=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_73','Room divider panels',#6862,$,$); -#6890=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_80','Sliding stacking panel partitions',#6862,$,$); -#6891=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_81','Softwood base boards',#6862,$,$); -#6892=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_82','Softwood framed panels',#6862,$,$); -#6893=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_83','Softwood palisade fence panels',#6862,$,$); -#6894=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_87','Timber base boards',#6862,$,$); -#6895=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_88','Timber board panels',#6862,$,$); -#6896=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_90','Timber sheet panels',#6862,$,$); -#6897=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_97','Wattle hurdles',#6862,$,$); -#6898=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_98','Willow wattle hurdles',#6862,$,$); -#6899=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63','Plastics-based boards and sheets',#6638,$,$); -#6900=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_15','Compact or solid grade high-pressure laminate (HPL) boards',#6899,$,$); -#6901=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_24','Drainage layer corrugated boards',#6899,$,$); -#6902=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_26','Expanded polystyrene (EPS) boards',#6899,$,$); -#6903=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_27','Extruded polyethylene (PE) foam boards',#6899,$,$); -#6904=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_29','Extruded polystyrene (XPS) boards',#6899,$,$); -#6905=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_33','Glass-reinforced plastics (GRP) profiled panels',#6899,$,$); -#6906=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_34','Glass-reinforced plastics (GRP) profiled sheets',#6899,$,$); -#6907=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_38','Hollow-core plastics sheets',#6899,$,$); -#6908=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_59','Phenolic foam boards',#6899,$,$); -#6909=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_60','Plastics and composite material boards',#6899,$,$); -#6910=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_61','Plastics base boards',#6899,$,$); -#6911=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_62','Plastics composite and recycled sheets',#6899,$,$); -#6912=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_63','Plastics composite laminate strips and boards',#6899,$,$); -#6913=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_64','Plastics weatherboards',#6899,$,$); -#6914=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_65','Polycarbonate profiled sheets',#6899,$,$); -#6915=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_66','Polyisocyanurate (PIR) foam boards',#6899,$,$); -#6916=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_67','Polyurethane (PUR) foam boards',#6899,$,$); -#6917=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_72','Recycled plastics deck boards',#6899,$,$); -#6918=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_81','Solid surface resin-based sheets',#6899,$,$); -#6919=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_92','Unplasticized polyvinyl chloride (PVC-U) deck boards',#6899,$,$); -#6920=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_93','Unplasticized polyvinyl chloride (PVC-U) profiled sheets',#6899,$,$); -#6921=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_94','Veneers and facings',#6638,$,$); -#6922=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_94_06','Balancing veneers',#6921,$,$); -#6923=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_94_22','Decorative continuous laminates (DCL or CPL)',#6921,$,$); -#6924=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_94_29','Fabric facings',#6921,$,$); -#6925=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_94_37','High-pressure decorative laminates (HPL or HPDL)',#6921,$,$); -#6926=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_94_46','Leather facings',#6921,$,$); -#6927=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_94_51','Melamine veneer facings',#6921,$,$); -#6928=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_94_52','Metal sheet facings',#6921,$,$); -#6929=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_94_94','Veneer edgings and lippings',#6921,$,$); -#6930=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_94_95','Vinyl sheet facings',#6921,$,$); -#6931=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_94_98','Wood veneers',#6921,$,$); -#6932=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97','Wood-based boards',#6638,$,$); -#6933=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_05','Bitumen-impregnated fibreboards',#6932,$,$); -#6934=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_07','Bitumen-impregnated softboards',#6932,$,$); -#6935=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_08','Blockboard core plywoods',#6932,$,$); -#6936=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_12','Cement-bonded particleboards',#6932,$,$); -#6937=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_16','Corkboards',#6932,$,$); -#6938=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_17','Cork composite laminate strips and boards',#6932,$,$); -#6939=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_21','Decorative laminated papers',#6932,$,$); -#6940=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_22','Decorative laminated plastics sheet veneered panels',#6932,$,$); -#6941=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_30','Fire-retardant plywoods',#6932,$,$); -#6942=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_33','General and utility veneer plywoods',#6932,$,$); -#6943=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_34','Gypsum-bonded fire protection boards',#6932,$,$); -#6944=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_35','Gypsum-bonded wood particle boards',#6932,$,$); -#6945=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_36','Hardboards',#6932,$,$); -#6946=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_37','Hardwood deck boards',#6932,$,$); -#6947=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_38','Hardwood fence boards',#6932,$,$); -#6948=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_42','Hardwood strips',#6932,$,$); -#6949=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_43','Hardwood weatherboards',#6932,$,$); -#6950=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_44','Hollow-core particleboards',#6932,$,$); -#6951=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_46','Laminboard core plywoods',#6932,$,$); -#6952=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_50','Marine plywoods',#6932,$,$); -#6953=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_52','Medium boards',#6932,$,$); -#6954=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_53','Medium density fibreboards',#6932,$,$); -#6955=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_54','Modified wood boards',#6932,$,$); -#6956=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_55','Modified wood weather boards',#6932,$,$); -#6957=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_58','Oriented strand boards',#6932,$,$); -#6958=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_60','Particleboards',#6932,$,$); -#6959=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_65','Polymer-coated plywoods',#6932,$,$); -#6960=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_77','Softboards',#6932,$,$); -#6961=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_78','Softwood deck boards',#6932,$,$); -#6962=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_79','Softwood fence boards',#6932,$,$); -#6963=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_83','Softwood strips',#6932,$,$); -#6964=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_84','Softwood weatherboards',#6932,$,$); -#6965=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_85','Specialist veneer plywoods',#6932,$,$); -#6966=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_86','Structural veneer plywoods',#6932,$,$); -#6967=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_87','Timber floor boards',#6932,$,$); -#6968=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_88','Timber lining boards',#6932,$,$); -#6969=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_89','Timber sarking boards',#6932,$,$); -#6970=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_91','Visual grade general veneer plywoods',#6932,$,$); -#6971=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_92','Wood fibre boards',#6932,$,$); -#6972=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_93','Wood laminate strips and boards',#6932,$,$); -#6973=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_94','Wood-plastics composite deck boards',#6932,$,$); -#6974=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_95','Wood-plastics composite weatherboards',#6932,$,$); -#6975=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_97','Wood-wool boards',#6932,$,$); -#6976=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_98','Wood-resin composite weatherboards',#6932,$,$); -#6977=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80','Smoke and fire control products',#6366,$,$); -#6978=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_79','Smoke and fire barriers',#6977,$,$); -#6979=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_79_01','Active smoke barriers',#6978,$,$); -#6980=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_79_03','Angled active fire curtain barriers',#6978,$,$); -#6981=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_79_14','Concertina fire curtains',#6978,$,$); -#6982=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_79_15','Concertina smoke curtains',#6978,$,$); -#6983=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_79_37','High temperature active smoke barriers',#6978,$,$); -#6984=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_79_38','Horizontal active fire curtain barriers',#6978,$,$); -#6985=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_79_39','Horizontal smoke curtains',#6978,$,$); -#6986=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_79_86','Static smoke barriers',#6978,$,$); -#6987=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_79_94','Vertical active fire curtain barriers',#6978,$,$); -#6988=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_79_95','Vertical smoke curtains',#6978,$,$); -#6989=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_79_96','Vertical smoke strip curtains',#6978,$,$); -#6990=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_80','Smoke and fire cavity barriers',#6977,$,$); -#6991=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_80_14','Coated woven glass fibre cloth flexible cavity barriers',#6990,$,$); -#6992=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_80_30','Fire insulating caps',#6990,$,$); -#6993=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_80_42','Intumescent coated foil mesh flexible cavity barriers',#6990,$,$); -#6994=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_80_43','Intumescent sheet cavity barriers',#6990,$,$); -#6995=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_80_44','Intumescent sleeved mineral wool cavity fire barriers',#6990,$,$); -#6996=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_80_51','Mineral wool wire reinforced mattress cavity barriers',#6990,$,$); -#6997=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_80_79','Sleeved mineral wool cavity barriers',#6990,$,$); -#6998=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_80_82','Sprayed mineral coated wire mesh flexible cavity barriers',#6990,$,$); -#6999=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_80_96','Wired mineral wool batt flexible cavity barriers',#6990,$,$); -#7000=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_81','Smoke and fire stopping',#6977,$,$); -#7001=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_81_12','Ceramic fibre fire stopping',#7000,$,$); -#7002=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_81_29','Flexible intumescent gap seals',#7000,$,$); -#7003=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_81_34','Glass oxide fire stopping',#7000,$,$); -#7004=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_81_42','Intumescent linear gap seals',#7000,$,$); -#7005=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_81_43','Intumescent pillows',#7000,$,$); -#7006=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_81_44','Intumescent trunking pillows',#7000,$,$); -#7007=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_81_51','Mineral wool fire stopping',#7000,$,$); -#7008=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93','Unit skin products',#6366,$,$); -#7009=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_45','Kerb units',#7008,$,$); -#7010=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_45_05','Asphalt kerbs',#7009,$,$); -#7011=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_45_18','Concrete kerbs',#7009,$,$); -#7012=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_45_21','Concrete safety kerbs',#7009,$,$); -#7013=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_45_24','Concrete transition and dropper kerbs',#7009,$,$); -#7014=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_45_26','Conservation kerbs',#7009,$,$); -#7015=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_45_56','Natural stone kerbs',#7009,$,$); -#7016=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_45_60','Pin kerbs',#7009,$,$); -#7017=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_45_62','Plastics kerbs',#7009,$,$); -#7018=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_45_70','Road kerbs',#7009,$,$); -#7019=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_45_90','Transition kerbs',#7009,$,$); -#7020=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_47','Level crossing surfacing products',#7008,$,$); -#7021=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_47_27','Embedded rail modular concrete level crossing units',#7020,$,$); -#7022=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_47_52','Modular panel level crossings',#7020,$,$); -#7023=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50','Masonry capping and coping units',#7008,$,$); -#7024=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_10','Calcium silicate capping units',#7023,$,$); -#7025=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_11','Calcium silicate coping units',#7023,$,$); -#7026=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_13','Cast stone capping units',#7023,$,$); -#7027=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_14','Cast stone coping units',#7023,$,$); -#7028=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_16','Clay brick capping units',#7023,$,$); -#7029=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_17','Clay brick coping units',#7023,$,$); -#7030=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_19','Clayware capping units',#7023,$,$); -#7031=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_20','Clayware coping units',#7023,$,$); -#7032=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_22','Concrete capping units',#7023,$,$); -#7033=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_23','Concrete coping units',#7023,$,$); -#7034=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_34','Glass-reinforced concrete (GRC) coping units',#7023,$,$); -#7035=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_55','Natural stone capping units',#7023,$,$); -#7036=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_56','Natural stone coping units',#7023,$,$); -#7037=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_76','Slate capping units',#7023,$,$); -#7038=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_77','Slate coping units',#7023,$,$); -#7039=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_51','Masonry dressing units',#7008,$,$); -#7040=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_51_35','Glass-reinforced concrete (GRC) built-in gable vents',#7039,$,$); -#7041=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_51_36','Glass-reinforced concrete (GRC) built-in keystones',#7039,$,$); -#7042=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_51_37','Glass-reinforced concrete (GRC) built-in plinths and string courses',#7039,$,$); -#7043=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_51_38','Glass-reinforced concrete (GRC) built-in quoins',#7039,$,$); -#7044=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_51_39','Glass-reinforced concrete (GRC) dressing gable vents',#7039,$,$); -#7045=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_51_40','Glass-reinforced concrete (GRC) dressing keystones',#7039,$,$); -#7046=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_51_41','Glass-reinforced concrete (GRC) dressing plinths and string courses',#7039,$,$); -#7047=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_51_42','Glass-reinforced concrete (GRC) dressing quoins',#7039,$,$); -#7048=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_51_56','Natural stone cornices',#7039,$,$); -#7049=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_51_57','Natural stone dentils',#7039,$,$); -#7050=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_51_58','Natural stone quoins',#7039,$,$); -#7051=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52','Masonry openings units',#7008,$,$); -#7052=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52_11','Calcium silicate sills',#7051,$,$); -#7053=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52_12','Cast stone sills',#7051,$,$); -#7054=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52_13','Clay brick sills',#7051,$,$); -#7055=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52_14','Clayware sills',#7051,$,$); -#7056=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52_15','Concrete sills',#7051,$,$); -#7057=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52_28','External extension sills',#7051,$,$); -#7058=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52_33','Glass-reinforced concrete (GRC) bay window sills',#7051,$,$); -#7059=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52_34','Glass-reinforced concrete (GRC) door canopies',#7051,$,$); -#7060=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52_35','Glass-reinforced concrete (GRC) door surrounds',#7051,$,$); -#7061=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52_36','Glass-reinforced concrete (GRC) sills',#7051,$,$); -#7062=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52_37','Glass-reinforced concrete (GRC) fireplace and hearth surrounds',#7051,$,$); -#7063=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52_56','Natural stone sills',#7051,$,$); -#7064=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52_76','Slate sills',#7051,$,$); -#7065=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_54','Metal capping and coping units',#7008,$,$); -#7066=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_54_02','Aluminium capping units',#7065,$,$); -#7067=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_54_03','Aluminium coping units',#7065,$,$); -#7068=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_54_11','Carbon steel capping units',#7065,$,$); -#7069=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_54_12','Carbon steel coping units',#7065,$,$); -#7070=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_54_15','Copper capping units',#7065,$,$); -#7071=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_54_16','Copper coping units',#7065,$,$); -#7072=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_54_46','Lead capping units',#7065,$,$); -#7073=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_54_47','Lead coping units',#7065,$,$); -#7074=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_54_98','Zinc capping units',#7065,$,$); -#7075=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_54_99','Zinc coping units',#7065,$,$); -#7076=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_55','Metal sills',#7008,$,$); -#7077=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_55_84','Steel sills',#7076,$,$); -#7078=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60','Paving units',#7008,$,$); -#7079=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_02','Aluminium edges',#7078,$,$); -#7080=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_08','Blister tactile pavers',#7078,$,$); -#7081=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_09','Clay pavers',#7078,$,$); -#7082=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_10','Clay paving tiles',#7078,$,$); -#7083=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_11','Clay surface channels',#7078,$,$); -#7084=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_12','Combined drainage and kerb units',#7078,$,$); -#7085=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_13','Concrete cellular pavers',#7078,$,$); -#7086=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_14','Concrete surface channels',#7078,$,$); -#7087=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_15','Concrete edging units',#7078,$,$); -#7088=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_16','Concrete flags',#7078,$,$); -#7089=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_17','Concrete paving blocks',#7078,$,$); -#7090=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_19','Concrete pavers',#7078,$,$); -#7091=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_20','Concrete quadrant and angle kerbs',#7078,$,$); -#7092=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_22','Concrete setts',#7078,$,$); -#7093=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_23','Concrete tactile flags',#7078,$,$); -#7094=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_26','Corduroy tactile pavers',#7078,$,$); -#7095=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_33','Glass-reinforced concrete (GRC) paving tiles',#7078,$,$); -#7096=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_52','Natural stone blocks',#7078,$,$); -#7097=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_53','Natural stone flags',#7078,$,$); -#7098=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_54','Natural stone cobbles',#7078,$,$); -#7099=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_55','Natural stone surface channels',#7078,$,$); -#7100=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_57','Natural stone setts',#7078,$,$); -#7101=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_58','Natural stone paving slabs',#7078,$,$); -#7102=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_59','Natural stone tactile pavers',#7078,$,$); -#7103=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_61','Plastics cellular pavers',#7078,$,$); -#7104=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_63','Plastics pavers',#7078,$,$); -#7105=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_65','Plastics surface channels',#7078,$,$); -#7106=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_78','Special composite paving units',#7078,$,$); -#7107=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_80','Stainless steel edges',#7078,$,$); -#7108=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_70','Rail track paving',#7008,$,$); -#7109=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_70_11','Cattle-cum-trespass guards',#7108,$,$); -#7110=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_70_70','Rail infill panels',#7108,$,$); -#7111=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72','Roofing and cladding units',#7008,$,$); -#7112=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_08','Bitumen membrane shingles',#7111,$,$); -#7113=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_11','Ceramic slates',#7111,$,$); -#7114=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_12','Clay interlocking tiles',#7111,$,$); -#7115=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_13','Clay plain tiles',#7111,$,$); -#7116=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_14','Clay tile coursing fittings',#7111,$,$); -#7117=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_15','Clay tile ornamental fittings',#7111,$,$); -#7118=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_16','Clay tile vertical tiling angle fittings',#7111,$,$); -#7119=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_17','Concrete interlocking tiles',#7111,$,$); -#7120=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_18','Concrete plain tiles',#7111,$,$); -#7121=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_19','Concrete tile coursing fittings',#7111,$,$); -#7122=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_20','Concrete tile ornamental fittings',#7111,$,$); -#7123=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_21','Concrete tile vertical tiling angle fittings',#7111,$,$); -#7124=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_30','Fibre cement slates',#7111,$,$); -#7125=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_31','Fibre-cement slate coursing fittings',#7111,$,$); -#7126=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_36','Hardwood shakes',#7111,$,$); -#7127=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_37','Hardwood shingles',#7111,$,$); -#7128=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_52','Metal tiles',#7111,$,$); -#7129=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_56','Natural slates',#7111,$,$); -#7130=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_57','Natural stone slates',#7111,$,$); -#7131=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_72','Reconstituted interlocking slates',#7111,$,$); -#7132=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_73','Reconstituted slate coursing fittings',#7111,$,$); -#7133=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_79','Slate coursing fittings',#7111,$,$); -#7134=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_96','Wood shakes',#7111,$,$); -#7135=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_97','Wood shingles',#7111,$,$); -#7136=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_98','Wood shingle pattern fittings',#7111,$,$); -#7137=IFCCLASSIFICATIONREFERENCE($,'Pr_25_96','Grid and grating skin products',#6366,$,$); -#7138=IFCCLASSIFICATIONREFERENCE($,'Pr_25_96_35','Grids and grilles',#7137,$,$); -#7139=IFCCLASSIFICATIONREFERENCE($,'Pr_25_96_35_03','Aluminium cattle grids',#7138,$,$); -#7140=IFCCLASSIFICATIONREFERENCE($,'Pr_25_96_35_11','Carbon steel cattle grids',#7138,$,$); -#7141=IFCCLASSIFICATIONREFERENCE($,'Pr_25_96_35_31','Footway gratings',#7138,$,$); -#7142=IFCCLASSIFICATIONREFERENCE($,'Pr_25_96_35_37','Headwall and outfall grilles',#7138,$,$); -#7143=IFCCLASSIFICATIONREFERENCE($,'Pr_25_96_35_53','Metal armouring grilles',#7138,$,$); -#7144=IFCCLASSIFICATIONREFERENCE($,'Pr_25_96_35_71','Recycled plastics cattle grids',#7138,$,$); -#7145=IFCCLASSIFICATIONREFERENCE($,'Pr_25_96_35_76','Sewage screens',#7138,$,$); -#7146=IFCCLASSIFICATIONREFERENCE($,'Pr_25_96_35_96','Water grilles',#7138,$,$); -#7147=IFCCLASSIFICATIONREFERENCE($,'Pr_30','Opening products',#4921,$,$); -#7148=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31','Formless openings products',#7147,$,$); -#7149=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_68','Putties and glazing compounds',#7148,$,$); -#7150=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_68_42','Intumescent putties',#7149,$,$); -#7151=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_68_47','Linseed oil putties',#7149,$,$); -#7152=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_68_51','Metal casement putties',#7149,$,$); -#7153=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_68_56','Non-setting glazing compounds',#7149,$,$); -#7154=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_68_74','Rubberizing glazing compounds',#7149,$,$); -#7155=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76','Sealants',#7148,$,$); -#7156=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_02','Acrylic construction joint sealants',#7155,$,$); -#7157=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_09','Butyl rubber construction joint sealants',#7155,$,$); -#7158=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_14','Cold-applied bituminous joint sealants',#7155,$,$); -#7159=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_15','Cold-applied concrete pavement bituminous joint sealants',#7155,$,$); -#7160=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_16','Construction joint sealants',#7155,$,$); -#7161=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_26','Edge sealants',#7155,$,$); -#7162=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_27','Electrical insulating compounds',#7155,$,$); -#7163=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_33','Glazing compounds and sealants',#7155,$,$); -#7164=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_34','Glazing joint sealants',#7155,$,$); -#7165=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_38','Hot-applied bituminous joint sealants',#7155,$,$); -#7166=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_39','Hydrophilic sealants',#7155,$,$); -#7167=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_40','Intumescent firestop sealants',#7155,$,$); -#7168=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_41','Intumescent foam fillers',#7155,$,$); -#7169=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_58','Oil-based mastic joint sealants',#7155,$,$); -#7170=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_62','Polysulfide construction joint sealants',#7155,$,$); -#7171=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_63','Polysulfide glazing compounds and sealants',#7155,$,$); -#7172=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_65','Polyurethane (PUR) construction joint sealants',#7155,$,$); -#7173=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_66','Polyurethane (PUR) expanding foam fillers',#7155,$,$); -#7174=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_77','Silicone construction joint sealants',#7155,$,$); -#7175=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_78','Silicone glazing compounds and sealants',#7155,$,$); -#7176=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_84','Structural sealant glazing bonding sealants',#7155,$,$); -#7177=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_85','Structural sealant glazing weather sealants',#7155,$,$); -#7178=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_96','Waterproof gap filling sealants',#7155,$,$); -#7179=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36','Hardware products',#7147,$,$); -#7180=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08','Bolting, latching and locking hardware',#7179,$,$); -#7181=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_06','Barrel bolts',#7180,$,$); -#7182=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_11','Cabinet locks',#7180,$,$); -#7183=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_12','Cam locks',#7180,$,$); -#7184=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_13','Cavity sliding door locks',#7180,$,$); -#7185=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_15','Coin-operated locks',#7180,$,$); -#7186=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_16','Combination padlocks',#7180,$,$); -#7187=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_18','Cremorne bolts',#7180,$,$); -#7188=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_19','Cylinder locks',#7180,$,$); -#7189=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_20','Deadbolts',#7180,$,$); -#7190=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_21','Digital door locks',#7180,$,$); -#7191=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_22','Door bolts',#7180,$,$); -#7192=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_23','Door catches',#7180,$,$); -#7193=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_24','Door latches',#7180,$,$); -#7194=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_25','Door chains and locks',#7180,$,$); -#7195=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_26','Door privacy indicator bolts',#7180,$,$); -#7196=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_27','Electric locks',#7180,$,$); -#7197=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_28','Emergency exit devices',#7180,$,$); -#7198=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_29','Espagnolette bolts',#7180,$,$); -#7199=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_30','Fanlight catches',#7180,$,$); -#7200=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_31','Field gate spring catch sets',#7180,$,$); -#7201=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_32','Flush bolts',#7180,$,$); -#7202=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_33','Furniture locks',#7180,$,$); -#7203=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_34','Gate latches and catches',#7180,$,$); -#7204=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_35','Gate throw over loops',#7180,$,$); -#7205=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_42','Indicator locks',#7180,$,$); -#7206=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_43','Key card locks',#7180,$,$); -#7207=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_44','Key deposit locks',#7180,$,$); -#7208=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_45','Knob locks',#7180,$,$); -#7209=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_46','Lever handle locks',#7180,$,$); -#7210=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_48','Locker hasps',#7180,$,$); -#7211=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_51','Microswitch locks',#7180,$,$); -#7212=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_52','Mortice bolts',#7180,$,$); -#7213=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_53','Mortice locks',#7180,$,$); -#7214=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_54','Multipoint door locks',#7180,$,$); -#7215=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_56','Night latches',#7180,$,$); -#7216=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_60','Pad bolts',#7180,$,$); -#7217=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_61','Padlock hasps and staples',#7180,$,$); -#7218=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_62','Padlocks and keys',#7180,$,$); -#7219=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_63','Panic exit devices',#7180,$,$); -#7220=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_68','Push-button locks',#7180,$,$); -#7221=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_71','Rim locks',#7180,$,$); -#7222=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_73','Roller catches',#7180,$,$); -#7223=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_75','Safety deposit locks',#7180,$,$); -#7224=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_76','Sash locks',#7180,$,$); -#7225=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_77','Single point bolts',#7180,$,$); -#7226=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_80','Sliding security screen door locks',#7180,$,$); -#7227=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_84','Special function door locks',#7180,$,$); -#7228=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_87','Thief resistant door locks',#7180,$,$); -#7229=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_88','Time delay locks',#7180,$,$); -#7230=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_91','Tubular mortice latches',#7180,$,$); -#7231=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_94','Vending machine locks',#7180,$,$); -#7232=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_95','Window casement fasteners',#7180,$,$); -#7233=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_96','Window latches',#7180,$,$); -#7234=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_97','Window locks',#7180,$,$); -#7235=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_98','Window sash fasteners',#7180,$,$); -#7236=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_33','General hardware',#7179,$,$); -#7237=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_33_20','Door edge protectors',#7236,$,$); -#7238=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_33_22','Door knockers',#7236,$,$); -#7239=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_33_24','Door stops',#7236,$,$); -#7240=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_33_27','Escutcheons',#7236,$,$); -#7241=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_33_29','Finger plates',#7236,$,$); -#7242=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_33_31','Fixed boot scrapers',#7236,$,$); -#7243=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_33_45','Kick plates',#7236,$,$); -#7244=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_33_68','Push plates',#7236,$,$); -#7245=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_33_72','Roses',#7236,$,$); -#7246=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_33_76','Security viewers',#7236,$,$); -#7247=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36','Hinges and hanging hardware',#7179,$,$); -#7248=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_04','Anti finger-trap stiles',#7247,$,$); -#7249=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_06','Ball-bearing hinges',#7247,$,$); -#7250=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_07','Barrel hinges',#7247,$,$); -#7251=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_08','Boxed sash window hanging fittings',#7247,$,$); -#7252=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_09','Butt door hinges',#7247,$,$); -#7253=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_10','Butt window hinges',#7247,$,$); -#7254=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_11','Cabinet and counter top hinges',#7247,$,$); -#7255=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_15','Concealed hinges',#7247,$,$); -#7256=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_16','Continuous hinges',#7247,$,$); -#7257=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_17','Cranked hinges',#7247,$,$); -#7258=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_22','Door pivots',#7247,$,$); -#7259=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_23','Door track and running gear',#7247,$,$); -#7260=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_24','Drawer runners',#7247,$,$); -#7261=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_28','Field gate hinges',#7247,$,$); -#7262=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_29','Floor springs',#7247,$,$); -#7263=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_30','Flush hinges',#7247,$,$); -#7264=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_31','Friction hinges',#7247,$,$); -#7265=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_32','Friction pivot hinges',#7247,$,$); -#7266=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_34','Gate hinges',#7247,$,$); -#7267=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_46','Lift-off hinges',#7247,$,$); -#7268=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_66','Projection door hinges',#7247,$,$); -#7269=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_67','Projection window hinges',#7247,$,$); -#7270=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_71','Rising butt door hinges',#7247,$,$); -#7271=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_75','Sash window spiral balances',#7247,$,$); -#7272=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_79','Single axis door hinges',#7247,$,$); -#7273=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_80','Single axis window hinges',#7247,$,$); -#7274=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_84','Spring hinges',#7247,$,$); -#7275=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_88','Tee hinges',#7247,$,$); -#7276=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_96','Window hinges',#7247,$,$); -#7277=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59','Opening hardware',#7179,$,$); -#7278=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_15','Controlled door closers',#7277,$,$); -#7279=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_22','Door coordinators',#7277,$,$); -#7280=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_24','Door limiting stays',#7277,$,$); -#7281=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_25','Door lever handle sets',#7277,$,$); -#7282=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_29','Flush pull handles',#7277,$,$); -#7283=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_31','Furniture stays',#7277,$,$); -#7284=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_32','Garage door holders',#7277,$,$); -#7285=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_33','Gate closers',#7277,$,$); -#7286=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_34','Gate handles',#7277,$,$); -#7287=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_35','Gate springs',#7277,$,$); -#7288=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_36','Gate wheels',#7277,$,$); -#7289=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_38','Holders and hooks',#7277,$,$); -#7290=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_45','Knobs',#7277,$,$); -#7291=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_50','Magnetic hold',#7277,$,$); -#7292=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_52','Midrail push plates',#7277,$,$); -#7293=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_64','Pull handles',#7277,$,$); -#7294=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_76','Sash window pulls',#7277,$,$); -#7295=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_78','Screen door closers',#7277,$,$); -#7296=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_92','Uncontrolled door closers',#7277,$,$); -#7297=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_94','Window casement stays',#7277,$,$); -#7298=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_95','Window latch and lock operating handles',#7277,$,$); -#7299=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_96','Window over centre casement stays',#7277,$,$); -#7300=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_97','Window remote manual openers',#7277,$,$); -#7301=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_98','Window restrictor stays',#7277,$,$); -#7302=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59','Openings and opening component products',#7147,$,$); -#7303=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_01','Access ramps',#7302,$,$); -#7304=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_01_11','Vehicle ramps',#7303,$,$); -#7305=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_01_23','Dog ramps',#7303,$,$); -#7306=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_01_27','Equipment loading ramps',#7303,$,$); -#7307=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_01_90','Train boarding ramps',#7303,$,$); -#7308=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_01_96','Wheelchair ramps',#7303,$,$); -#7309=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07','Blinds and shading devices',#7302,$,$); -#7310=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_02','Aluminium shutters',#7309,$,$); -#7311=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_03','Anti-glare screens',#7309,$,$); -#7312=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_05','Awnings',#7309,$,$); -#7313=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_07','Blackout blinds',#7309,$,$); -#7314=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_26','External roller blinds',#7309,$,$); -#7315=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_27','External venetian blinds',#7309,$,$); -#7316=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_60','Panel blinds',#7309,$,$); -#7317=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_64','Pinoleum blinds',#7309,$,$); -#7318=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_66','Pleated blinds',#7309,$,$); -#7319=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_68','Polyvinyl chloride (PVC) shutters',#7309,$,$); -#7320=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_72','Roller blinds',#7309,$,$); -#7321=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_73','Roman blinds',#7309,$,$); -#7322=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_86','Sunscreens',#7309,$,$); -#7323=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_94','Venetian blinds',#7309,$,$); -#7324=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_95','Vertical blinds',#7309,$,$); -#7325=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_96','Wood shutters',#7309,$,$); -#7326=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09','Brise-soleils and components',#7302,$,$); -#7327=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_01','Aluminium brise-soleil brace arms/struts',#7326,$,$); -#7328=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_02','Aluminium brise-soleil carrier members',#7326,$,$); -#7329=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_03','Aluminium brise-soleil louvre blades',#7326,$,$); -#7330=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_04','Aluminium brise-soleil support arms',#7326,$,$); -#7331=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_05','Aluminium brise-soleil units',#7326,$,$); -#7332=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_11','Carbon steel brise-soleil brace arms/struts',#7326,$,$); -#7333=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_12','Carbon steel brise-soleil carrier members',#7326,$,$); -#7334=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_13','Carbon steel brise-soleil louvre blades',#7326,$,$); -#7335=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_14','Carbon steel brise-soleil support arms',#7326,$,$); -#7336=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_15','Carbon steel brise-soleil units',#7326,$,$); -#7337=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_33','Glass brise-soleil louvre blades',#7326,$,$); -#7338=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_62','Plastics brise-soleil louvre blades',#7326,$,$); -#7339=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_63','Plastics brise-soleil units',#7326,$,$); -#7340=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_82','Stainless steel brise-soleil brace arms/struts',#7326,$,$); -#7341=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_83','Stainless steel brise-soleil carrier members',#7326,$,$); -#7342=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_84','Stainless steel brise-soleil louvre blades',#7326,$,$); -#7343=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_85','Stainless steel brise-soleil support arms',#7326,$,$); -#7344=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_86','Stainless steel brise-soleil units',#7326,$,$); -#7345=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_90','Wood brise-soleil carrier members',#7326,$,$); -#7346=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_91','Wood brise-soleil louvre blades',#7326,$,$); -#7347=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_92','Wood brise-soleil support arms',#7326,$,$); -#7348=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_93','Wood brise-soleil units',#7326,$,$); -#7349=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23','Door frames and leaves',#7302,$,$); -#7350=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_02','Aluminium door frames',#7349,$,$); -#7351=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_11','Carbon steel door frames',#7349,$,$); -#7352=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_15','Composite door frames',#7349,$,$); -#7353=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_16','Composite door leaves',#7349,$,$); -#7354=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_32','Frameless glass door leaves',#7349,$,$); -#7355=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_34','Glass reinforced plastics (GRP) door leaves',#7349,$,$); -#7356=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_47','Louvre door leaves',#7349,$,$); -#7357=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_50','Matchboarded door leaves',#7349,$,$); -#7358=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_53','Metal door leaves',#7349,$,$); -#7359=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_84','Stainless steel door frames',#7349,$,$); -#7360=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_91','Unplasticized polyvinyl chloride (PVC-U) door frames',#7349,$,$); -#7361=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_92','Unplasticized polyvinyl chloride (PVC-U) door leaves',#7349,$,$); -#7362=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_96','Wood door frames',#7349,$,$); -#7363=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_97','Wood flush door leaves',#7349,$,$); -#7364=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_98','Wood panelled door leaves',#7349,$,$); -#7365=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24','Doorsets',#7302,$,$); -#7366=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_04','Automatic revolving doorsets',#7365,$,$); -#7367=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_14','Collapsible gate and grille sets',#7365,$,$); -#7368=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_15','Combination doorsets',#7365,$,$); -#7369=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_16','Composite doorsets',#7365,$,$); -#7370=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_28','Fire doorsets',#7365,$,$); -#7371=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_30','Flexible doorsets',#7365,$,$); -#7372=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_34','Glass reinforced plastics (GRP) doorsets',#7365,$,$); -#7373=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_37','High security doorsets',#7365,$,$); -#7374=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_38','High speed doorsets',#7365,$,$); -#7375=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_48','Loading bay doorsets',#7365,$,$); -#7376=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_49','Louvre doorsets',#7365,$,$); -#7377=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_50','Manual revolving doorsets',#7365,$,$); -#7378=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_52','Metal doorsets',#7365,$,$); -#7379=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_64','Polyvinyl chloride (PVC) strip curtain sets',#7365,$,$); -#7380=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_75','Sectional overhead doorsets',#7365,$,$); -#7381=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_80','Sliding door and partition sets',#7365,$,$); -#7382=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_81','Sliding folding doorsets',#7365,$,$); -#7383=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_83','Sliding folding shutters',#7365,$,$); -#7384=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_92','Unplasticized polyvinyl chloride (PVC-U) doorsets',#7365,$,$); -#7385=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_93','Up-and-over doorsets',#7365,$,$); -#7386=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_97','Wood doorsets',#7365,$,$); -#7387=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_28','Escape products',#7302,$,$); -#7388=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_28_26','Escape chairs',#7387,$,$); -#7389=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_28_27','Escape chutes',#7387,$,$); -#7390=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_28_28','Escape slides',#7387,$,$); -#7391=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_28_78','Slings',#7387,$,$); -#7392=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_29','Fixed roof ventilators, terminals and accessories',#7302,$,$); -#7393=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_29_02','Abutment ventilators',#7392,$,$); -#7394=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_29_15','Combined eaves fascia grilles and ventilator trays',#7392,$,$); -#7395=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_29_30','Flat roof ventilators',#7392,$,$); -#7396=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_29_62','Plastics eaves underlay support',#7392,$,$); -#7397=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_29_64','Plastics rafter ventilator trays',#7392,$,$); -#7398=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_29_71','Roof ridge ventilator tiles',#7392,$,$); -#7399=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_29_72','Roof slope terminals',#7392,$,$); -#7400=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_29_73','Roof slope ventilator tiles',#7392,$,$); -#7401=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_29_74','Roof terminals',#7392,$,$); -#7402=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_29_75','Roof ventilator unit',#7392,$,$); -#7403=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_29_77','Rotary roof ventilators',#7392,$,$); -#7404=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_29_82','Strip ventilators',#7392,$,$); -#7405=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33','Gate surrounds and leaves',#7302,$,$); -#7406=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_02','Aluminium sheet gate leaves',#7405,$,$); -#7407=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_03','Aluminium vertical rail gate leaves',#7405,$,$); -#7408=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_11','Carbon steel expanded mesh gate leaves',#7405,$,$); -#7409=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_12','Carbon steel field gate leaves',#7405,$,$); -#7410=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_13','Carbon steel palisade gate leaves',#7405,$,$); -#7411=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_14','Carbon steel sheet gate leaves',#7405,$,$); -#7412=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_15','Carbon steel vertical section gate leaves',#7405,$,$); -#7413=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_16','Carbon steel welded mesh gate leaves',#7405,$,$); -#7414=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_33','Gate arches',#7405,$,$); -#7415=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_34','Glass infill gate leaves',#7405,$,$); -#7416=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_35','Glazing plastics gate leaves',#7405,$,$); -#7417=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_36','Hardwood field gate leaves',#7405,$,$); -#7418=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_37','Hardwood gate leaves',#7405,$,$); -#7419=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_38','Hardwood gate surrounds',#7405,$,$); -#7420=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_39','Hardwood palisade gate leaves',#7405,$,$); -#7421=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_52','Metal gate surrounds',#7405,$,$); -#7422=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_62','Plastics gate leaves',#7405,$,$); -#7423=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_63','Plywood sheet gate leaves',#7405,$,$); -#7424=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_78','Stainless steel expanded mesh gate leaves',#7405,$,$); -#7425=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_82','Stainless steel sheet gate leaves',#7405,$,$); -#7426=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_84','Stainless steel vertical rail gate leaves',#7405,$,$); -#7427=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_98','Wrought iron decorative gate leaves',#7405,$,$); -#7428=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_99','Wrought iron vertical rail gate leaves',#7405,$,$); -#7429=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34','Gates and turnstiles',#7302,$,$); -#7430=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_01','Aluminium full height turnstiles',#7429,$,$); -#7431=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_02','Aluminium gates',#7429,$,$); -#7432=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_03','Aluminium safety gates',#7429,$,$); -#7433=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_10','Canal lock gates',#7429,$,$); -#7434=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_11','Carbon steel bridle gates',#7429,$,$); -#7435=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_12','Carbon steel dog gates',#7429,$,$); -#7436=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_13','Carbon steel full height turnstiles',#7429,$,$); -#7437=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_14','Carbon steel gates',#7429,$,$); -#7438=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_15','Carbon steel half height turnstiles',#7429,$,$); -#7439=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_16','Carbon steel kissing gates',#7429,$,$); -#7440=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_17','Carbon steel motorbike inhibitors',#7429,$,$); -#7441=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_18','Carbon steel safety gates',#7429,$,$); -#7442=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_20','Composite gates',#7429,$,$); -#7443=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_30','Flood gates',#7429,$,$); -#7444=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_35','Glazed gates',#7429,$,$); -#7445=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_36','Hardwood bridle gates',#7429,$,$); -#7446=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_37','Hardwood dog gates',#7429,$,$); -#7447=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_38','Hardwood gates',#7429,$,$); -#7448=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_39','Hardwood kissing gates',#7429,$,$); -#7449=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_40','Hardwood ladder stiles',#7429,$,$); -#7450=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_41','Hardwood post and rail stiles',#7429,$,$); -#7451=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_65','Plastics gates',#7429,$,$); -#7452=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_78','Stainless steel full height turnstiles',#7429,$,$); -#7453=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_80','Stainless steel gates',#7429,$,$); -#7454=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_88','Stainless steel half height turnstiles',#7429,$,$); -#7455=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_90','Stainless steel safety gates',#7429,$,$); -#7456=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_98','Wrought iron gates',#7429,$,$); -#7457=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_36','Hatches and access panels',#7302,$,$); -#7458=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_36_01','Access panels',#7457,$,$); -#7459=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_36_02','Aluminium access hatches',#7457,$,$); -#7460=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_36_11','Carbon steel access hatches',#7457,$,$); -#7461=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_36_30','Floor hatches',#7457,$,$); -#7462=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_36_50','Manual trapdoors',#7457,$,$); -#7463=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_36_74','Roof hatches',#7457,$,$); -#7464=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_36_76','Self-closing safety hatches',#7457,$,$); -#7465=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_36_78','Self-closing trapdoors',#7457,$,$); -#7466=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_36_80','Stainless steel access hatches',#7457,$,$); -#7467=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_36_96','Wall hatches',#7457,$,$); -#7468=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_46','Lift barriers',#7302,$,$); -#7469=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_46_46','Lift landing doorsets',#7468,$,$); -#7470=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_46_47','Lift landing frames',#7468,$,$); -#7471=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_46_48','Lift landing sills',#7468,$,$); -#7472=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_46_49','Lift platform barriers',#7468,$,$); -#7473=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_46_63','Platform lift landing doorsets and gates',#7468,$,$); -#7474=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48','Louvres and components',#7302,$,$); -#7475=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_02','Aluminium louvre blades',#7474,$,$); -#7476=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_03','Aluminium louvre frames',#7474,$,$); -#7477=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_04','Aluminium louvre panel units',#7474,$,$); -#7478=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_11','Carbon steel louvre blades',#7474,$,$); -#7479=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_12','Carbon steel louvre frames',#7474,$,$); -#7480=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_13','Carbon steel louvre panel units',#7474,$,$); -#7481=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_34','Glass louvre blades',#7474,$,$); -#7482=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_52','Mirror louvre units',#7474,$,$); -#7483=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_65','Plastic louvre blades',#7474,$,$); -#7484=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_77','Screening and ventilation access doors',#7474,$,$); -#7485=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_78','Screening and ventilation louvre support frames',#7474,$,$); -#7486=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_83','Stainless steel louvre blades',#7474,$,$); -#7487=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_84','Stainless steel louvre frames',#7474,$,$); -#7488=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_85','Stainless steel louvre panel units',#7474,$,$); -#7489=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_96','Wood louvre blades',#7474,$,$); -#7490=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_97','Wood louvre frames',#7474,$,$); -#7491=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_98','Wood louvre panel units',#7474,$,$); -#7492=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_57','Opening security and protection products',#7302,$,$); -#7493=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_57_04','Anti-burglar window bars',#7492,$,$); -#7494=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_57_07','Bird guards',#7492,$,$); -#7495=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_57_08','Bird guard mesh',#7492,$,$); -#7496=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_57_28','Escalator shutters',#7492,$,$); -#7497=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_57_29','Firebreak shutters',#7492,$,$); -#7498=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_57_40','Insect guard mesh',#7492,$,$); -#7499=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_57_41','Insect guards',#7492,$,$); -#7500=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_57_58','Overhead ventilators',#7492,$,$); -#7501=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_57_76','Security shutters',#7492,$,$); -#7502=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_57_77','Security window screens',#7492,$,$); -#7503=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_58','Operable roof ventilators',#7302,$,$); -#7504=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_58_50','Manual control glazed roof ventilators',#7503,$,$); -#7505=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_58_88','Thermostatic control glazed roof ventilators',#7503,$,$); -#7506=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_59','Operable vehicular barriers',#7302,$,$); -#7507=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_59_11','Cantilevered sliding beam vehicular barriers',#7506,$,$); -#7508=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_59_38','Height restrictors',#7506,$,$); -#7509=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_59_39','Horizontal swing vehicular barriers',#7506,$,$); -#7510=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_59_72','Rising arm vehicular barriers',#7506,$,$); -#7511=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_59_79','Sliding vehicular barriers',#7506,$,$); -#7512=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_60','Passenger boarding bridges',#7302,$,$); -#7513=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_60_03','Apron drive passenger boarding bridges',#7512,$,$); -#7514=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_60_15','Commuter passenger boarding bridges',#7512,$,$); -#7515=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_60_56','Noseloader passenger boarding bridges',#7512,$,$); -#7516=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_60_80','Ship boarding gangways',#7512,$,$); -#7517=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_60_87','T bridge passenger boarding bridges',#7512,$,$); -#7518=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_61','Pavement and floorlight and venting products',#7302,$,$); -#7519=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_61_32','Glazed floorlight panels',#7518,$,$); -#7520=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_61_33','Glazed lift-out floorlight access panel',#7518,$,$); -#7521=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_61_34','Glazed lift-out access pavement light panels',#7518,$,$); -#7522=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_61_35','Glazed pavement light panels',#7518,$,$); -#7523=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_61_36','Glazed smoke venting panels',#7518,$,$); -#7524=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_61_57','Non-glazed smoke venting panels',#7518,$,$); -#7525=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_71','Refuse and linen chute inlets and openings',#7302,$,$); -#7526=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_71_12','Chute automatic fire doors',#7525,$,$); -#7527=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_71_13','Chute door interlocks',#7525,$,$); -#7528=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_71_21','Refuse chute discharge outlets',#7525,$,$); -#7529=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_71_22','Refuse chute doorsets',#7525,$,$); -#7530=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_71_23','Refuse chute hoppers',#7525,$,$); -#7531=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_71_46','Linen chute discharge outlets',#7525,$,$); -#7532=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_71_47','Linen chute doorsets',#7525,$,$); -#7533=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_71_48','Linen chute hoppers',#7525,$,$); -#7534=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72','Rooflights',#7302,$,$); -#7535=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_17','Continuous rooflights',#7534,$,$); -#7536=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_21','Daylight pipes',#7534,$,$); -#7537=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_24','Dormers',#7534,$,$); -#7538=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_25','Double glazed light pipe diffusers',#7534,$,$); -#7539=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_30','Factory-assembled insulating rooflights (FAIRs)',#7534,$,$); -#7540=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_31','Framed rooflights',#7534,$,$); -#7541=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_33','Glazed lift-out rooflight access panels',#7534,$,$); -#7542=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_34','Glazed rooflight panels',#7534,$,$); -#7543=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_42','Individual rooflights',#7534,$,$); -#7544=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_46','Lantern lights',#7534,$,$); -#7545=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_48','Light reflectors (motorized)',#7534,$,$); -#7546=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_57','North lights',#7534,$,$); -#7547=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_77','Skylights',#7534,$,$); -#7548=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_94','Ventilating light pipe diffusers',#7534,$,$); -#7549=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_84','Shutters and grilles',#7302,$,$); -#7550=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_84_30','Fire-resisting roller shutters',#7549,$,$); -#7551=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_84_72','Roller grilles',#7549,$,$); -#7552=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_84_73','Roller shutters',#7549,$,$); -#7553=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_94','Ventilation grilles',#7302,$,$); -#7554=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_94_04','Air ventilation grilles',#7553,$,$); -#7555=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_94_06','Air transfer grilles',#7553,$,$); -#7556=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_94_26','Eaves fascia grilles',#7553,$,$); -#7557=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_94_31','Fire-resisting air transfer grilles',#7553,$,$); -#7558=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_94_32','Fire-resisting air transfer grilles with smoke shutters',#7553,$,$); -#7559=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_94_78','Soffit grilles',#7553,$,$); -#7560=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_94_90','Trickle vents',#7553,$,$); -#7561=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_96','Wall venting products',#7302,$,$); -#7562=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_96_11','Cavity ventilators',#7561,$,$); -#7563=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_96_33','Gas venting grilles',#7561,$,$); -#7564=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_96_35','Ground-level vent outlets',#7561,$,$); -#7565=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_96_92','Ventilation ducts',#7561,$,$); -#7566=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_96_93','Ventilation gratings',#7561,$,$); -#7567=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_96_96','Wall vent outlets',#7561,$,$); -#7568=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_97','Window panels',#7302,$,$); -#7569=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_97_16','Glazed security window panels',#7568,$,$); -#7570=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_97_80','Speak through units',#7568,$,$); -#7571=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_97_90','Transaction units',#7568,$,$); -#7572=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_97_94','Vision panels',#7568,$,$); -#7573=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_98','Window units',#7302,$,$); -#7574=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_98_02','Aluminium window units',#7573,$,$); -#7575=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_98_03','Aluminium frame roof window units',#7573,$,$); -#7576=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_98_15','Composite window units',#7573,$,$); -#7577=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_98_34','Glass louvre window units',#7573,$,$); -#7578=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_98_72','Rigid polyurethane frame roof window units',#7573,$,$); -#7579=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_98_83','Steel window units',#7573,$,$); -#7580=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_98_84','Steel frame roof window units',#7573,$,$); -#7581=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_98_92','Unplasticized polyvinyl chloride (PVC-U) window units',#7573,$,$); -#7582=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_98_93','Unplasticized polyvinyl chloride (PVC-U) roof window units',#7573,$,$); -#7583=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_98_96','Wood window units',#7573,$,$); -#7584=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_98_97','Wood frame roof window units',#7573,$,$); -#7585=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_99','Window walls',#7302,$,$); -#7586=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_99_02','Aluminium window walls',#7585,$,$); -#7587=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_99_15','Composite window walls',#7585,$,$); -#7588=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_99_83','Steel window walls',#7585,$,$); -#7589=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_99_92','Unplasticized polyvinylchloride (PVC-U) window walls',#7585,$,$); -#7590=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_99_96','Wood window walls',#7585,$,$); -#7591=IFCCLASSIFICATIONREFERENCE($,'Pr_35','Covering and finishing products',#4921,$,$); -#7592=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31','Formless covering and finish products',#7591,$,$); -#7593=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05','Asphalt, bitumen and resin mixtures',#7592,$,$); -#7594=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_03','Asphalt concrete (AC) base courses',#7593,$,$); -#7595=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_04','Asphalt concrete (AC) binder courses',#7593,$,$); -#7596=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_05','Asphalt concrete (AC) surface courses',#7593,$,$); -#7597=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_07','Bitumen coated chippings',#7593,$,$); -#7598=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_08','Bitumen emulsion and glass fibre sandwich matrices',#7593,$,$); -#7599=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_10','Bonded grit surfacings',#7593,$,$); -#7600=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_19','Cut-back and fluxed bitumen binders',#7593,$,$); -#7601=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_36','Hard paving-grade bitumen',#7593,$,$); -#7602=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_37','Hot-applied oxidized bitumen coatings',#7593,$,$); -#7603=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_38','Hot-rolled asphalt (HRA) base courses',#7593,$,$); -#7604=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_39','Hot-rolled asphalt (HRA) binder courses',#7593,$,$); -#7605=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_40','Hot-rolled asphalt (HRA) surface courses and slurries',#7593,$,$); -#7606=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_42','Impervious textured sports surfacings',#7593,$,$); -#7607=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_50','Mastic asphalt (MA) surface courses',#7593,$,$); -#7608=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_60','Paving-grade bitumens',#7593,$,$); -#7609=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_64','Polyurethane-bound ethylene propylene diene monomer (EPDM) rubber crumb surfacings',#7593,$,$); -#7610=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_65','Porous asphalt concrete (PAC) surface courses',#7593,$,$); -#7611=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_70','Resin-bonded aggregate surfacings',#7593,$,$); -#7612=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_71','Resin-bound mixed aggregate surfacings',#7593,$,$); -#7613=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_72','Roofing, tanking and flooring mastic asphalt (MA)',#7593,$,$); -#7614=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_75','Sand asphalt',#7593,$,$); -#7615=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_83','Stone mastic asphalt (SMA) binder courses',#7593,$,$); -#7616=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_84','Stone mastic asphalt (SMA) regulating courses',#7593,$,$); -#7617=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_85','Stone mastic asphalt (SMA) surface courses',#7593,$,$); -#7618=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06','Bedding and underlay compounds',#7592,$,$); -#7619=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_12','Cementitious levelling screed mixes',#7618,$,$); -#7620=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_15','Concrete (granolithic) wearing screed mixes',#7618,$,$); -#7621=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_28','Fibre-reinforced levelling screed mixes',#7618,$,$); -#7622=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_29','Fine concrete levelling screed mixes',#7618,$,$); -#7623=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_31','Floor seals',#7618,$,$); -#7624=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_32','Flow applied flooring',#7618,$,$); -#7625=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_36','Heavy-duty flow-applied flooring',#7618,$,$); -#7626=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_37','Heavy-duty screed flooring',#7618,$,$); -#7627=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_38','High-build floor coatings',#7618,$,$); -#7628=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_47','Lightweight aggregate levelling screed mixes',#7618,$,$); -#7629=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_55','Multilayer flooring',#7618,$,$); -#7630=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_64','Polymer-modified levelling screed mixes',#7618,$,$); -#7631=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_65','Polymer-modified wearing screed mixes',#7618,$,$); -#7632=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_69','Quick-drying levelling screed mixes',#7618,$,$); -#7633=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_71','Ready-mixed levelling and wearing screeds',#7618,$,$); -#7634=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_72','Ready-mixed self-smoothing calcium sulfate screeds',#7618,$,$); -#7635=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_73','Ready-mixed trowelled calcium sulfate screeds',#7618,$,$); -#7636=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_77','Screed flooring',#7618,$,$); -#7637=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_78','Self-smoothing levelling screed mixes',#7618,$,$); -#7638=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_79','Self-smoothing wearing screed mixes',#7618,$,$); -#7639=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_80','Smoothing and levelling underlay compounds',#7618,$,$); -#7640=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22','Decorative coatings',#7592,$,$); -#7641=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_02','Aluminium paints',#7640,$,$); -#7642=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_12','Casein paints',#7640,$,$); -#7643=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_13','Cement paints',#7640,$,$); -#7644=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_15','Concrete finishing coats',#7640,$,$); -#7645=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_16','Concrete flash coats',#7640,$,$); -#7646=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_17','Concrete floor dyes',#7640,$,$); -#7647=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_18','Concrete floor paints',#7640,$,$); -#7648=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_19','Concrete stains',#7640,$,$); -#7649=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_23','Distemper',#7640,$,$); -#7650=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_37','High pigment waterborne paint',#7640,$,$); -#7651=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_47','Limewashes',#7640,$,$); -#7652=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_52','Micaceous iron oxide paints',#7640,$,$); -#7653=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_54','Multi-colour coatings',#7640,$,$); -#7654=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_55','Multi-colour finish spatter coatings',#7640,$,$); -#7655=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_58','Oil-bound distempers',#7640,$,$); -#7656=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_62','Plant oil paints',#7640,$,$); -#7657=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_64','Plastic texture paints',#7640,$,$); -#7658=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_72','Resin-based breathable masonry paints',#7640,$,$); -#7659=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_74','Semi-transparent timber dyes',#7640,$,$); -#7660=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_75','Semi-transparent timber oils',#7640,$,$); -#7661=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_76','Semi-transparent timber stains',#7640,$,$); -#7662=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_77','Silicate-based masonry coatings',#7640,$,$); -#7663=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_79','Solvent-based finishing coats',#7640,$,$); -#7664=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_80','Solvent-borne gloss finishes',#7640,$,$); -#7665=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_81','Solvent-borne masonry paints',#7640,$,$); -#7666=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_82','Solvent-borne matt and flat finishes',#7640,$,$); -#7667=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_83','Solvent-borne mid-sheen finishes',#7640,$,$); -#7668=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_87','Tallow lime washes',#7640,$,$); -#7669=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_95','Waterborne gloss finishes',#7640,$,$); -#7670=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_96','Waterborne masonry paints',#7640,$,$); -#7671=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_97','Waterborne matt and flat finishes',#7640,$,$); -#7672=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_98','Waterborne mid-sheen finishes',#7640,$,$); -#7673=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64','Plasters and renders',#7592,$,$); -#7674=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_01','Acrylic plasters',#7673,$,$); -#7675=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_02','Acrylic renders',#7673,$,$); -#7676=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_07','Biocidal renders',#7673,$,$); -#7677=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_08','Bonding plasters',#7673,$,$); -#7678=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_09','Browning plasters',#7673,$,$); -#7679=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_12','Cementitious renders',#7673,$,$); -#7680=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_14','Clay plasters',#7673,$,$); -#7681=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_29','Factory mixed plasters',#7673,$,$); -#7682=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_31','Fibrous plasters',#7673,$,$); -#7683=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_32','Finish plasters',#7673,$,$); -#7684=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_35','Gypsum plasters',#7673,$,$); -#7685=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_42','Insulating plasters',#7673,$,$); -#7686=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_47','Lime plasters',#7673,$,$); -#7687=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_48','Lime renders',#7673,$,$); -#7688=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_64','Polymer plasters',#7673,$,$); -#7689=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_65','Polymer-modified renders',#7673,$,$); -#7690=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_67','Projection plasters',#7673,$,$); -#7691=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_70','Render-grade resins',#7673,$,$); -#7692=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_71','Renovating plasters',#7673,$,$); -#7693=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_76','Scagliola',#7673,$,$); -#7694=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_77','Silicone renders',#7673,$,$); -#7695=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_80','Solid cast plasters',#7673,$,$); -#7696=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_84','Squash court plasters',#7673,$,$); -#7697=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_85','Stucco',#7673,$,$); -#7698=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_86','Synthetic plasters',#7673,$,$); -#7699=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_98','X-ray undercoat plasters',#7673,$,$); -#7700=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_99','Zinc oxychloride plasters',#7673,$,$); -#7701=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65','Preparation materials, fillers and stoppers',#7592,$,$); -#7702=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_01','Abrasives',#7701,$,$); -#7703=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_02','Abrasive blocks',#7701,$,$); -#7704=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_12','Cement and grout fillers',#7701,$,$); -#7705=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_13','Chemical fillers',#7701,$,$); -#7706=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_20','Decorator\X2\2019\X0\s caulks',#7701,$,$); -#7707=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_21','Decorator\X2\2019\X0\s flexible fillers',#7701,$,$); -#7708=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_22','Degreaser solutions',#7701,$,$); -#7709=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_23','Detergent solutions',#7701,$,$); -#7710=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_24','Dry air pressured abrasives',#7701,$,$); -#7711=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_25','Dry air pressured micro-abrasives',#7701,$,$); -#7712=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_26','Dusting powders',#7701,$,$); -#7713=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_27','Efflorescence control compounds',#7701,$,$); -#7714=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_28','End grain sealers',#7701,$,$); -#7715=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_29','Fine surface fillers',#7701,$,$); -#7716=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_30','Finishing compounds',#7701,$,$); -#7717=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_31','Fire-resistant fillers',#7701,$,$); -#7718=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_34','Gypsum-based bedding compounds',#7701,$,$); -#7719=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_50','Masonry stabilizers',#7701,$,$); -#7720=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_74','Rust removers',#7701,$,$); -#7721=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_79','Stoppers',#7701,$,$); -#7722=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_80','Stopper fillers',#7701,$,$); -#7723=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_82','Surface fillers',#7701,$,$); -#7724=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_95','Wax-based fillers',#7701,$,$); -#7725=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_96','Wet air pressured abrasives',#7701,$,$); -#7726=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_97','Wetting agents',#7701,$,$); -#7727=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_98','Wood knotting solutions',#7701,$,$); -#7728=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66','Preparatory coatings',#7592,$,$); -#7729=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_02','Adhesion promoters',#7728,$,$); -#7730=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_03','Alkali-resisting primers',#7728,$,$); -#7731=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_07','Basecoat stains',#7728,$,$); -#7732=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_08','Bitumen primers',#7728,$,$); -#7733=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_09','Bonding coats',#7728,$,$); -#7734=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_15','Combined barrier and bonding coats',#7728,$,$); -#7735=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_16','Concrete curing coatings',#7728,$,$); -#7736=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_21','Debonding compounds',#7728,$,$); -#7737=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_22','Dressing compounds',#7728,$,$); -#7738=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_26','Etching primers',#7728,$,$); -#7739=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_30','Floor covering primers',#7728,$,$); -#7740=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_34','Gilding basecoats',#7728,$,$); -#7741=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_50','Mastic asphalt (MA) primers',#7728,$,$); -#7742=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_51','Metallic lead primers',#7728,$,$); -#7743=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_52','Modified bitumen primers',#7728,$,$); -#7744=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_53','Mordant solutions',#7728,$,$); -#7745=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_55','Multi-colour finish basecoats',#7728,$,$); -#7746=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_57','Non-bituminous primers',#7728,$,$); -#7747=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_60','Paving primers',#7728,$,$); -#7748=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_62','Plaster primers',#7728,$,$); -#7749=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_63','Plasterboard primers',#7728,$,$); -#7750=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_67','Primer-sealers',#7728,$,$); -#7751=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_68','Primer-undercoats',#7728,$,$); -#7752=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_70','Reinforcement treatments',#7728,$,$); -#7753=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_71','Resin coating primers',#7728,$,$); -#7754=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_75','Sanded primers',#7728,$,$); -#7755=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_76','Silicate-based primers',#7728,$,$); -#7756=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_77','Sealant primers',#7728,$,$); -#7757=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_78','Slip plane bituminous emulsion paint primers',#7728,$,$); -#7758=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_80','Solvent-borne basecoats',#7728,$,$); -#7759=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_81','Solvent-borne metal primers',#7728,$,$); -#7760=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_82','Solvent-borne undercoats',#7728,$,$); -#7761=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_83','Solvent-borne wood primers',#7728,$,$); -#7762=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_88','Thinners',#7728,$,$); -#7763=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_92','Universal primers',#7728,$,$); -#7764=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_94','Water-based acrylic primers',#7728,$,$); -#7765=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_95','Waterborne basecoats',#7728,$,$); -#7766=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_96','Waterborne metal primers',#7728,$,$); -#7767=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_97','Waterborne thinned undercoats',#7728,$,$); -#7768=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_98','Waterborne wood primers',#7728,$,$); -#7769=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_99','Waterborne undercoats',#7728,$,$); -#7770=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67','Preservative, additives and fire-retardant treatments',#7592,$,$); -#7771=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_01','Acrylic retarder additives',#7770,$,$); -#7772=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_07','Borate pellet and rod preservatives',#7770,$,$); -#7773=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_08','Boron compound preservatives',#7770,$,$); -#7774=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_14','Clear flame-retardant finishes',#7770,$,$); -#7775=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_15','Copper-organic preservatives',#7770,$,$); -#7776=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_24','Dry interior fire-retardant solutions',#7770,$,$); -#7777=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_34','Glycol-borne preservatives',#7770,$,$); -#7778=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_37','House longhorn beetle timber treatments',#7770,$,$); -#7779=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_39','Humidity-resistant fire-retardant solutions',#7770,$,$); -#7780=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_41','Insecticidal paint additives',#7770,$,$); -#7781=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_42','Interior fire-retardant solutions',#7770,$,$); -#7782=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_46','Latex retarder additives',#7770,$,$); -#7783=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_47','Leach-resistant fire-retardant solutions',#7770,$,$); -#7784=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_52','Micro-emulsion-borne preservatives',#7770,$,$); -#7785=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_59','Organic solvent-borne preservatives',#7770,$,$); -#7786=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_88','Thatch fire-preservative treatments',#7770,$,$); -#7787=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_89','Thatch fire-retardant treatments',#7770,$,$); -#7788=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_96','Waterborne preservatives',#7770,$,$); -#7789=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_97','Water based micro-emulsion preservatives',#7770,$,$); -#7790=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_98','Water-based organic preservatives',#7770,$,$); -#7791=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68','Protective coatings',#7592,$,$); -#7792=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_01','Acrylic-based waterproof coatings',#7791,$,$); -#7793=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_02','Anionic bitumen emulsions',#7791,$,$); -#7794=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_03','Anodizing',#7791,$,$); -#7795=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_04','Anti-carbonation coatings',#7791,$,$); -#7796=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_05','Anti-graffiti coatings',#7791,$,$); -#7797=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_06','Barrier coatings',#7791,$,$); -#7798=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_07','Bitumen-based black coatings',#7791,$,$); -#7799=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_09','Bitumen emulsion waterproof coatings',#7791,$,$); -#7800=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_10','Black bitumen coatings',#7791,$,$); -#7801=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_11','Cationic bitumen emulsions',#7791,$,$); -#7802=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_12','Cellulose coatings',#7791,$,$); -#7803=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_13','Chrome plating',#7791,$,$); -#7804=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_14','Clear floor varnishes',#7791,$,$); -#7805=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_15','Clear varnishes',#7791,$,$); -#7806=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_16','Cold-applied bitumen solutions',#7791,$,$); -#7807=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_17','Cold-applied polymer-modified bitumen waterproof coatings',#7791,$,$); -#7808=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_18','Concrete polishes',#7791,$,$); -#7809=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_19','Copper plating',#7791,$,$); -#7810=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_21','Cork tile polyurethane (PUR) varnishes',#7791,$,$); -#7811=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_27','Epoxy resin coatings',#7791,$,$); -#7812=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_28','Epoxy underwater coatings',#7791,$,$); -#7813=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_29','Flame-retardant coatings',#7791,$,$); -#7814=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_31','Floor dyes',#7791,$,$); -#7815=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_32','Floor polishes',#7791,$,$); -#7816=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_33','Fungicidal coatings',#7791,$,$); -#7817=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_34','Galvanized coatings',#7791,$,$); -#7818=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_35','Gold plating',#7791,$,$); -#7819=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_36','Hard wax oils',#7791,$,$); -#7820=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_37','Heat-resisting coatings',#7791,$,$); -#7821=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_38','Hot-applied polymer-modified bitumen waterproof coatings',#7791,$,$); -#7822=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_39','Hot dip galvanizings',#7791,$,$); -#7823=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_40','Hygienic coatings',#7791,$,$); -#7824=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_43','Intumescent protective coatings',#7791,$,$); -#7825=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_46','Lacquers',#7791,$,$); -#7826=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_47','Liquid tanking resins',#7791,$,$); -#7827=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_51','Mastic asphalt (MA) polishes',#7791,$,$); -#7828=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_52','Membrane walkway coatings',#7791,$,$); -#7829=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_55','Multi-colour finish glaze coats',#7791,$,$); -#7830=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_60','Patination oils',#7791,$,$); -#7831=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_62','Polymer resin waterproof coatings',#7791,$,$); -#7832=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_63','Polyester resin waterproof coatings',#7791,$,$); -#7833=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_64','Polyurethane (PUR) waterproof coatings',#7791,$,$); -#7834=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_65','Polyvinylidene fluoride (PVDF) coatings',#7791,$,$); -#7835=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_66','Powder coatings',#7791,$,$); -#7836=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_69','Red oxide paints',#7791,$,$); -#7837=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_70','Resin floor coatings',#7791,$,$); -#7838=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_72','Sacrificial anti-corrosion coatings',#7791,$,$); -#7839=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_74','Sherardized coatings',#7791,$,$); -#7840=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_75','Silver plating',#7791,$,$); -#7841=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_79','Sprayed monolithic coating finishing coats',#7791,$,$); -#7842=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_80','Solvent-free waterproof coatings',#7791,$,$); -#7843=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_81','Solar reflective coatings',#7791,$,$); -#7844=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_82','Solar reflective anti-corrosion coatings',#7791,$,$); -#7845=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_83','Spray-applied fireproof coatings',#7791,$,$); -#7846=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_84','Spray-applied thermal insulation',#7791,$,$); -#7847=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_85','Steel fence powder coatings',#7791,$,$); -#7848=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_86','Surface preservation products',#7791,$,$); -#7849=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_87','Tar-based black coatings',#7791,$,$); -#7850=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_88','Thermoplastic block copolymer waterproof coatings',#7791,$,$); -#7851=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_96','Water-dispersible polymer waterproof coatings',#7791,$,$); -#7852=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_97','Water repellents',#7791,$,$); -#7853=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_98','Yacht varnishes',#7791,$,$); -#7854=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_99','Zinc plating',#7791,$,$); -#7855=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77','Surface sealers',#7592,$,$); -#7856=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_05','Anti-graffiti sealers',#7855,$,$); -#7857=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_08','Bitumen-based impregnating sealers',#7855,$,$); -#7858=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_12','Cement-based screed surface sealers',#7855,$,$); -#7859=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_15','Concrete sealers',#7855,$,$); -#7860=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_16','Cork flooring sealers',#7855,$,$); -#7861=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_24','Dry shake finish sealers',#7855,$,$); -#7862=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_25','Dustproofing sealers',#7855,$,$); -#7863=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_30','Floor surface sealers',#7855,$,$); -#7864=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_42','Intumescent coating sealers',#7855,$,$); -#7865=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_46','Liquid applied membranes',#7855,$,$); -#7866=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_50','Mastic asphalt (MA) oil-resistant sealers',#7855,$,$); -#7867=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_60','Paving sealers and stabilizers',#7855,$,$); -#7868=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_72','Resin floor sealers',#7855,$,$); -#7869=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_76','Sealers',#7855,$,$); -#7870=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_84','Sprayed monolithic coating sealers',#7855,$,$); -#7871=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_92','Ultraviolet (UV)-resistant sealers',#7855,$,$); -#7872=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_96','Wood floor sealers',#7855,$,$); -#7873=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85','Specialist coatings',#7592,$,$); -#7874=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_02','Acoustic chute coatings',#7873,$,$); -#7875=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_03','Anti-climb paints',#7873,$,$); -#7876=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_04','Anti-slip floor coatings',#7873,$,$); -#7877=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_05','Anti-static carpet treatments',#7873,$,$); -#7878=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_13','Chlorinated rubber road markings',#7873,$,$); -#7879=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_21','Damp proof coatings',#7873,$,$); -#7880=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_24','Dry rot paints',#7873,$,$); -#7881=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_26','Elastomeric paints',#7873,$,$); -#7882=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_27','Epoxy paint road markings',#7873,$,$); -#7883=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_29','Fluorescent paints',#7873,$,$); -#7884=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_35','Gilding leaf',#7873,$,$); -#7885=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_36','Gilding size',#7873,$,$); -#7886=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_46','Light duty road markings',#7873,$,$); -#7887=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_47','Line marking paints',#7873,$,$); -#7888=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_48','Luminous paints',#7873,$,$); -#7889=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_51','Metallic wear resistant, low friction coatings',#7873,$,$); -#7890=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_60','Phosphorescent paints',#7873,$,$); -#7891=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_61','Polyurethane resin based paint',#7873,$,$); -#7892=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_62','Polyurethane (PUR) rubber spray surfaces',#7873,$,$); -#7893=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_65','Preformed road markings',#7873,$,$); -#7894=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_70','Radiator enamels',#7873,$,$); -#7895=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_72','Reflective coatings',#7873,$,$); -#7896=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_78','Slip plane bituminous emulsion paints',#7873,$,$); -#7897=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_80','Slip-resistant surface treatments',#7873,$,$); -#7898=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_81','Sound damping coatings',#7873,$,$); -#7899=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_82','Surface hardeners',#7873,$,$); -#7900=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_88','Thermoplastic line markings',#7873,$,$); -#7901=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_90','Thermoplastic road markings',#7873,$,$); -#7902=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_94','Vitreous enamels',#7873,$,$); -#7903=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_96','Waterborne resin coatings',#7873,$,$); -#7904=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_97','Wear and abrasion resistant coating',#7873,$,$); -#7905=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_98','Wearing surface dry shake materials',#7873,$,$); -#7906=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57','Non-rigid sheet, mat and strip covering and finish products',#7591,$,$); -#7907=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11','Carpets, carpet tiles, coverings, underlays and mats',#7906,$,$); -#7908=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_05','Axminster carpets',#7907,$,$); -#7909=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_07','Bonded carpets',#7907,$,$); -#7910=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_08','Bonded carpet tiles',#7907,$,$); -#7911=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_11','Cellular plastics underlays',#7907,$,$); -#7912=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_13','Cellular rubber underlays',#7907,$,$); -#7913=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_15','Combined fibrous or non-fibrous underlays',#7907,$,$); -#7914=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_24','Dry felt paper interlays',#7907,$,$); -#7915=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_26','Entrance mats',#7907,$,$); -#7916=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_27','Ethylene propylene diene monomer (EPDM) rubber mats',#7907,$,$); -#7917=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_28','Exercise mats',#7907,$,$); -#7918=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_29','Flat needled carpet tiles',#7907,$,$); -#7919=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_30','Flat needled carpets',#7907,$,$); -#7920=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_31','Flocked carpets',#7907,$,$); -#7921=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_36','Hessian-faced cork underlays',#7907,$,$); -#7922=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_40','Impregnated fibrous underlays',#7907,$,$); -#7923=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_45','Knitted carpets',#7907,$,$); -#7924=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_46','Loose-laid cushion matting',#7907,$,$); -#7925=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_47','Loose-laid fatigue matting',#7907,$,$); -#7926=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_49','Loose-laid matting',#7907,$,$); -#7927=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_56','Needled felt underlays',#7907,$,$); -#7928=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_57','Needled pile carpet tiles',#7907,$,$); -#7929=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_58','Needled pile carpets',#7907,$,$); -#7930=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_62','Pile carpet tiles',#7907,$,$); -#7931=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_64','Pile carpets',#7907,$,$); -#7932=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_66','Polybutyl teraphthalate (PBT) bristle mats',#7907,$,$); -#7933=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_68','Polyvinyl chloride (PVC) bristle mats',#7907,$,$); -#7934=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_72','Reed mats',#7907,$,$); -#7935=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_74','Rubber crumb underlays',#7907,$,$); -#7936=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_85','Synthetic grass surfaces',#7907,$,$); -#7937=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_91','Tufted carpets',#7907,$,$); -#7938=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_97','Wilton carpets',#7907,$,$); -#7939=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_15','Composite surfacing and underlay products',#7906,$,$); -#7940=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_15_40','In situ polymer shock absorption layers',#7939,$,$); -#7941=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_15_42','Interlocking shock absorption panels',#7939,$,$); -#7942=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_15_75','Sand enveloped shock absorption layers',#7939,$,$); -#7943=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_15_80','Sheet format shock absorption layers',#7939,$,$); -#7944=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22','Decorative papers and roll coverings',#7906,$,$); -#7945=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_08','Border papers',#7944,$,$); -#7946=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_15','Cork roll coverings',#7944,$,$); -#7947=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_38','Heavy-duty roll coverings',#7944,$,$); -#7948=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_42','Ingrain roll coverings',#7944,$,$); -#7949=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_46','Linen-backed lining papers',#7944,$,$); -#7950=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_48','Lining papers',#7944,$,$); -#7951=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_51','Metal foil roll coverings',#7944,$,$); -#7952=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_52','Metallic effect roll coverings',#7944,$,$); -#7953=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_53','Metallized roll coverings',#7944,$,$); -#7954=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_54','Mural roll coverings',#7944,$,$); -#7955=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_58','Non-woven lining papers',#7944,$,$); -#7956=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_60','Paper roll coverings',#7944,$,$); -#7957=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_72','Relief roll coverings',#7944,$,$); -#7958=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_88','Textile roll coverings',#7944,$,$); -#7959=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_90','Textured effect roll coverings',#7944,$,$); -#7960=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_95','Vinyl roll coverings',#7944,$,$); -#7961=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71','Resilient floor coverings',#7906,$,$); -#7962=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_02','Agglomerated composition cork tiles',#7961,$,$); -#7963=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_04','Agglomerated composition cork tiles with polyvinyl chloride (PVC) wearing layer',#7961,$,$); -#7964=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_12','Composite sheets',#7961,$,$); -#7965=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_13','Composite rubber tiles',#7961,$,$); -#7966=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_14','Composite tiles',#7961,$,$); -#7967=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_15','Cork linoleum (cork carpet) sheets',#7961,$,$); -#7968=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_17','Cork-backed linoleum sheets',#7961,$,$); -#7969=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_19','Cork-backed polyvinyl chloride (PVC) sheets',#7961,$,$); -#7970=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_20','Cork-backed polyvinyl chloride (PVC) tiles',#7961,$,$); -#7971=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_22','Cork sheets',#7961,$,$); -#7972=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_23','Cork tiles',#7961,$,$); -#7973=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_25','Ethylene propylene diene monomer (EPDM) rubber tiles',#7961,$,$); -#7974=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_26','Expanded (cushioned) polyvinyl chloride (PVC) sheets',#7961,$,$); -#7975=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_27','Expanded (cushioned) polyvinyl chloride (PVC) tiles',#7961,$,$); -#7976=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_28','Filled fibrous-backed polyvinyl chloride (PVC) sheets',#7961,$,$); -#7977=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_30','Floor surface coating resins',#7961,$,$); -#7978=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_31','Foam-backed linoleum sheets',#7961,$,$); -#7979=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_32','Foam backed polyvinyl chloride (PVC) sheets',#7961,$,$); -#7980=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_33','Foam backed polyvinyl chloride (PVC) tiles',#7961,$,$); -#7981=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_34','Foam-backed smooth rubber sheets',#7961,$,$); -#7982=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_35','Granular rubber sheets',#7961,$,$); -#7983=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_36','Granular rubber tiles',#7961,$,$); -#7984=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_37','Hammered rubber tiles',#7961,$,$); -#7985=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_43','Jute or polyester felt-backed polyvinyl chloride (PVC) sheets',#7961,$,$); -#7986=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_44','Jute or polyester felt-backed polyvinyl chloride (PVC) tiles',#7961,$,$); -#7987=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_46','Linoleum sheets',#7961,$,$); -#7988=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_49','Linoleum tiles',#7961,$,$); -#7989=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_60','Particle-based enhanced wet area polyvinyl chloride (PVC) sheets',#7961,$,$); -#7990=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_61','Particle-based enhanced slip-resistant polyvinyl chloride (PVC) sheets',#7961,$,$); -#7991=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_62','Particle-based enhanced slip-resistant polyvinyl chloride (PVC) tiles',#7961,$,$); -#7992=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_67','Polyvinyl chloride (PVC) sheets',#7961,$,$); -#7993=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_68','Polyvinyl chloride (PVC) tiles',#7961,$,$); -#7994=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_72','Relief rubber sheets',#7961,$,$); -#7995=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_73','Relief rubber tiles',#7961,$,$); -#7996=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_74','Rubber mats and sheets',#7961,$,$); -#7997=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_75','Rubber tiles',#7961,$,$); -#7998=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_76','Semi-flexible polyvinyl chloride (PVC) tiles',#7961,$,$); -#7999=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_80','Smooth rubber sheets',#7961,$,$); -#8000=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_84','Smooth rubber tiles',#7961,$,$); -#8001=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_86','Solid rubber sheets',#7961,$,$); -#8002=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_87','Stabilizing underlays',#7961,$,$); -#8003=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_88','Textiles',#7906,$,$); -#8004=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_88_16','Cotton textiles',#8003,$,$); -#8005=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_88_46','Linen textiles',#8003,$,$); -#8006=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_88_97','Woollen textiles',#8003,$,$); -#8007=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_88_98','Wool-nylon textiles',#8003,$,$); -#8008=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90','Trim products',#7591,$,$); -#8009=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_07','Beads, stops and fillets',#8008,$,$); -#8010=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_07_04','Angle fillets',#8009,$,$); -#8011=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_07_08','Bitumen impregnated fibreboard fillets',#8009,$,$); -#8012=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_07_15','Copper cames',#8009,$,$); -#8013=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_07_24','Dry lining beads',#8009,$,$); -#8014=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_07_33','Glazing beads',#8009,$,$); -#8015=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_07_47','Lead cames',#8009,$,$); -#8016=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_07_63','Plaster beads',#8009,$,$); -#8017=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_07_72','Render beads',#8009,$,$); -#8018=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_07_73','Render stops',#8009,$,$); -#8019=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_07_88','Thin-coat plaster beads',#8009,$,$); -#8020=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_07_89','Timber fillets',#8009,$,$); -#8021=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_09','Bridge expansion joints',#8008,$,$); -#8022=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_09_11','Cantilever expansion comb or tooth joints',#8021,$,$); -#8023=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_09_27','Elastomeric expansion joint in metal runners',#8021,$,$); -#8024=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_09_28','Elastomeric pads',#8021,$,$); -#8025=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_09_71','Reinforced elastomeric expansion joints',#8021,$,$); -#8026=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_09_85','Supported expansion joints',#8021,$,$); -#8027=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15','Concrete construction joint accessories',#8008,$,$); -#8028=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_04','Armoured joints',#8027,$,$); -#8029=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_08','Bottom-of-slab plastics crack inducers',#8027,$,$); -#8030=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_11','Carbon steel arris armourings',#8027,$,$); -#8031=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_12','Carbon steel shear load connectors',#8027,$,$); -#8032=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_13','Carbon steel strip crack inducers',#8027,$,$); -#8033=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_14','Centrally-placed rubber flexible waterstops',#8027,$,$); -#8034=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_15','Centrally-placed polyvinyl chloride (PVC) elastomer flexible waterstops',#8027,$,$); -#8035=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_16','Centrally-placed unplasticized polyvinyl chloride (PVC-U) flexible waterstops',#8027,$,$); -#8036=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_19','Coated metal waterstops',#8027,$,$); -#8037=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_37','Headed stud shear connectors',#8027,$,$); -#8038=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_42','Injectable hose waterstops',#8027,$,$); -#8039=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_48','Loop connectors',#8027,$,$); -#8040=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_63','Plastics strip crack inducers',#8027,$,$); -#8041=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_72','Rubber flexible waterstops',#8027,$,$); -#8042=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_74','Rubber hydrophilic waterstops',#8027,$,$); -#8043=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_77','Shrinkage tube crack inducers',#8027,$,$); -#8044=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_82','Stainless steel arris armourings',#8027,$,$); -#8045=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_83','Stainless steel shear load connectors',#8027,$,$); -#8046=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_84','Stainless steel strip crack inducers',#8027,$,$); -#8047=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_85','Surface mounted polyvinyl chloride (PVC) flexible waterstops',#8027,$,$); -#8048=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_86','Synthetic elastomer hydrophilic waterstops',#8027,$,$); -#8049=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_88','Thermal break shear load connectors',#8027,$,$); -#8050=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_89','Thermal break connection plates',#8027,$,$); -#8051=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_22','Dividing and edge strips',#8008,$,$); -#8052=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_22_36','Hardwood edgings',#8051,$,$); -#8053=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_22_51','Metal angle edgings',#8051,$,$); -#8054=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_22_52','Metal edgings',#8051,$,$); -#8055=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_22_63','Plastics edgings',#8051,$,$); -#8056=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_22_66','Preformed tiling strip joints',#8051,$,$); -#8057=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_22_72','Recycled plastics edgings',#8051,$,$); -#8058=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_22_80','Softwood edgings',#8051,$,$); -#8059=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_22_88','Timber grass edgings',#8051,$,$); -#8060=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_27','Expansion joints',#8008,$,$); -#8061=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_27_11','Chloroprene and aluminium expansion joints',#8060,$,$); -#8062=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_27_12','Chloroprene and copper expansion joints',#8060,$,$); -#8063=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_27_13','Chloroprene and lead expansion joints',#8060,$,$); -#8064=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_27_14','Chloroprene and stainless steel expansion joints',#8060,$,$); -#8065=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_27_15','Chloroprene and zinc expansion joints',#8060,$,$); -#8066=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28','External trims and sills',#8008,$,$); -#8067=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_02','Aluminium fascias',#8066,$,$); -#8068=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_04','Anti-climb security devices',#8066,$,$); -#8069=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_11','Carbon steel fascias',#8066,$,$); -#8070=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_15','Cover caps',#8066,$,$); -#8071=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_23','Double skin glass-reinforced plastics (GRP) components',#8066,$,$); -#8072=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_32','Glass-reinforced plastics (GRP) fa\X2\00E7\X0\ade components',#8066,$,$); -#8073=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_33','Glass-reinforced plastics (GRP) roof components',#8066,$,$); -#8074=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_36','Hardwood copings',#8066,$,$); -#8075=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_50','Membrane standing seam profiles',#8066,$,$); -#8076=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_51','Metal drip trims',#8066,$,$); -#8077=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_52','Metal finishing trims',#8066,$,$); -#8078=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_62','Plastics and composite material trim boards',#8066,$,$); -#8079=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_64','Polyvinyl chloride (PVC) standing seam profiles',#8066,$,$); -#8080=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_72','Roof membrane perimeter trims',#8066,$,$); -#8081=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_76','Single skin ribbed glass',#8066,$,$); -#8082=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_79','Softwood copings',#8066,$,$); -#8083=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_82','Stainless steel cappings and copings',#8066,$,$); -#8084=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_83','Stainless steel fascias',#8066,$,$); -#8085=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_84','Stainless steel undersills',#8066,$,$); -#8086=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_92','Unplasticized polyvinyl chloride (PVC-U) finishing trims',#8066,$,$); -#8087=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_93','Unplasticized polyvinyl chloride (PVC-U) sills',#8066,$,$); -#8088=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_95','Window sill boards',#8066,$,$); -#8089=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_96','Wood finishing trims',#8066,$,$); -#8090=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_97','Wood trim boards',#8066,$,$); -#8091=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_30','Flashings',#8008,$,$); -#8092=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_30_01','Aluminium flashings',#8091,$,$); -#8093=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_30_08','Bitumen-based flashings',#8091,$,$); -#8094=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_30_11','Carbon steel flashings',#8091,$,$); -#8095=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_30_15','Copper flashings',#8091,$,$); -#8096=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_30_18','Copper slates',#8091,$,$); -#8097=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_30_34','Glass-reinforced plastics (GRP) flashings',#8091,$,$); -#8098=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_30_46','Lead flashings',#8091,$,$); -#8099=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_30_47','Lead slates',#8091,$,$); -#8100=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_30_64','Polyethylene (PE)-based flashings',#8091,$,$); -#8101=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_30_72','Recycled plastics flashings',#8091,$,$); -#8102=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_30_83','Stainless steel flashings',#8091,$,$); -#8103=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_30_99','Zinc flashings',#8091,$,$); -#8104=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31','Floor and stair trims',#8008,$,$); -#8105=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_11','Carpet grippers',#8104,$,$); -#8106=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_12','Carpet gripper strips',#8104,$,$); -#8107=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_26','Flexible polyvinyl chloride (PVC) stair nosings',#8104,$,$); -#8108=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_27','Flexible stair coverings',#8104,$,$); -#8109=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_28','Floor construction joint trims',#8104,$,$); -#8110=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_29','Floor cover strips',#8104,$,$); -#8111=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_30','Floor dividing strips',#8104,$,$); -#8112=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_31','Floor edge trims',#8104,$,$); -#8113=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_32','Floor edging strips',#8104,$,$); -#8114=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_33','Floor threshold strips',#8104,$,$); -#8115=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_36','Hardwood floor threshold strips',#8104,$,$); -#8116=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_37','Hardwood stair trims',#8104,$,$); -#8117=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_50','Mat well frames',#8104,$,$); -#8118=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_58','One part floor transition strips',#8104,$,$); -#8119=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_66','Preformed strip joints to screeds',#8104,$,$); -#8120=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_70','Radiator pipe floor covers',#8104,$,$); -#8121=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_71','Raised access floor level-change trims',#8104,$,$); -#8122=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_72','Raised access floor vertical edging panels',#8104,$,$); -#8123=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_73','Render-grade resin coves',#8104,$,$); -#8124=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_74','Rigid stair nosings',#8104,$,$); -#8125=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_75','Rubber composite stair nosing inserts',#8104,$,$); -#8126=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_83','Stair rods',#8104,$,$); -#8127=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_84','Stair trims',#8104,$,$); -#8128=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_90','Two-part floor transition strips',#8104,$,$); -#8129=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_95','Wearing screed sawn-joint sealing strips',#8104,$,$); -#8130=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_96','Wood-based floor threshold strips',#8104,$,$); -#8131=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_97','Wood-based floor transition strips',#8104,$,$); -#8132=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33','Gaskets, weatherstrips and baffles',#8008,$,$); -#8133=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_12','Cellular rubber gaskets',#8132,$,$); -#8134=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_20','Curtain wall glazing and panel gaskets',#8132,$,$); -#8135=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_22','Door and window weatherstrips and seals',#8132,$,$); -#8136=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_23','Door threshold weatherstrips and seals',#8132,$,$); -#8137=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_24','Ethylene propylene diene monomer (EPDM) combined hydrophilic gaskets',#8132,$,$); -#8138=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_25','Ethylene propylene diene monomer (EPDM) gaskets',#8132,$,$); -#8139=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_26','Ethylene propylene diene monomer (EPDM) rubber section glazing trims',#8132,$,$); -#8140=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_28','Extruded polyvinyl chloride (PVC) glazing gaskets',#8132,$,$); -#8141=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_34','Glass-reinforced plastics (GRP) cladding neoprene gaskets',#8132,$,$); -#8142=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_39','Hydrophilic gaskets',#8132,$,$); -#8143=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_56','Neoprene baffles',#8132,$,$); -#8144=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_57','Non-cellular rubber gaskets',#8132,$,$); -#8145=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_64','Polypropylene baffles',#8132,$,$); -#8146=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_66','Pre-formed butyl strip glazing trims',#8132,$,$); -#8147=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_77','Single-sided glazing gaskets',#8132,$,$); -#8148=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_84','Stainless steel baffles',#8132,$,$); -#8149=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_86','Synthetic rubber glazing gaskets',#8132,$,$); -#8150=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_97','Weatherstripping',#8132,$,$); -#8151=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_99','Zipper gaskets',#8132,$,$); -#8152=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43','Interior wall and ceiling trims',#8008,$,$); -#8153=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_02','Aluminium skirtings',#8152,$,$); -#8154=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_03','Angle trims',#8152,$,$); -#8155=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_04','Arrises',#8152,$,$); -#8156=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_12','Ceiling perimeter trims',#8152,$,$); -#8157=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_13','Column guards',#8152,$,$); -#8158=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_14','Cork cove skirtings',#8152,$,$); -#8159=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_15','Corner guards',#8152,$,$); -#8160=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_16','Cover strips',#8152,$,$); -#8161=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_17','Coves',#8152,$,$); -#8162=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_21','Edge battens',#8152,$,$); -#8163=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_22','Edge trims',#8152,$,$); -#8164=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_29','Fibrous plaster mouldings',#8152,$,$); -#8165=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_30','Fire-insulating caps',#8152,$,$); -#8166=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_42','Intumescent protective castings',#8152,$,$); -#8167=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_47','Lighting cornices',#8152,$,$); -#8168=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_48','Medium density fibreboard (MDF) architraves',#8152,$,$); -#8169=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_49','Medium density fibreboard (MDF) backboards',#8152,$,$); -#8170=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_50','Medium density fibreboard (MDF) cover strips',#8152,$,$); -#8171=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_51','Medium density fibreboard (MDF) dado rails',#8152,$,$); -#8172=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_52','Medium density fibreboard (MDF) edge trims',#8152,$,$); -#8173=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_53','Medium density fibreboard (MDF) lining boards',#8152,$,$); -#8174=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_54','Medium density fibreboard (MDF) mouldings and trims',#8152,$,$); -#8175=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_55','Medium density fibreboard (MDF) mounting battens',#8152,$,$); -#8176=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_56','Medium density fibreboard (MDF) picture rails',#8152,$,$); -#8177=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_57','Medium density fibreboard (MDF) protection rails',#8152,$,$); -#8178=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_58','Medium density fibreboard (MDF) skirtings',#8152,$,$); -#8179=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_59','Metal skirtings',#8152,$,$); -#8180=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_60','Panel partition closer pieces',#8152,$,$); -#8181=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_61','Pilasters',#8152,$,$); -#8182=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_62','Plaster cornices',#8152,$,$); -#8183=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_63','Plastics skirtings',#8152,$,$); -#8184=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_64','Polyvinyl chloride (PVC) cove skirtings',#8152,$,$); -#8185=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_66','Preformed casings',#8152,$,$); -#8186=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_70','Radiator guards',#8152,$,$); -#8187=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_74','Rubber cove skirtings',#8152,$,$); -#8188=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_84','Solid cast plaster mouldings',#8152,$,$); -#8189=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_86','Wall protection panels',#8152,$,$); -#8190=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_87','Wood architraves',#8152,$,$); -#8191=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_88','Wood backboards',#8152,$,$); -#8192=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_89','Wood cover strips',#8152,$,$); -#8193=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_90','Wood dado rails',#8152,$,$); -#8194=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_91','Wood edge trims',#8152,$,$); -#8195=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_92','Wood fillets',#8152,$,$); -#8196=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_93','Wood lining boards',#8152,$,$); -#8197=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_94','Wood mouldings and trims',#8152,$,$); -#8198=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_95','Wood mounting battens',#8152,$,$); -#8199=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_96','Wood picture rails',#8152,$,$); -#8200=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_97','Wood protection rails',#8152,$,$); -#8201=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_98','Wood skirtings',#8152,$,$); -#8202=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_50','Masonry walling ancillary products',#8008,$,$); -#8203=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_50_03','Airbricks',#8202,$,$); -#8204=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_50_61','Perpend joint plastics cavity ventilators',#8202,$,$); -#8205=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_50_62','Perpend joint plastics weep holes',#8202,$,$); -#8206=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_50_63','Perpend joint metal weep holes',#8202,$,$); -#8207=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_50_64','Plastics cavity closers',#8202,$,$); -#8208=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_50_88','Tile creasings',#8202,$,$); -#8209=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_53','Movement joints',#8008,$,$); -#8210=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_53_11','Cast-in screed movement joints',#8209,$,$); -#8211=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_53_30','Fibre cement movement joints',#8209,$,$); -#8212=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_53_42','Insulated render system construction and movement joints',#8209,$,$); -#8213=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_53_50','Mastic asphalt (MA) movement joints',#8209,$,$); -#8214=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_53_52','Metal movement joint edging angles',#8209,$,$); -#8215=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_53_53','Metal section movement joints',#8209,$,$); -#8216=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_53_54','Minor flat roofing movement joints',#8209,$,$); -#8217=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_53_72','Resin flooring strip movement joints',#8209,$,$); -#8218=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_53_85','Sprayed monolithic coating movement joints',#8209,$,$); -#8219=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_53_86','Strip movement joints',#8209,$,$); -#8220=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_53_88','Timber flooring movement joints',#8209,$,$); -#8221=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_53_93','Unplasticized polyvinyl chloride (PVC-U) external render and plaster movement joints',#8209,$,$); -#8222=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_60','Paving studs and inserts',#8008,$,$); -#8223=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_60_22','Demarcation inserts',#8222,$,$); -#8224=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_60_41','Illuminated road studs',#8222,$,$); -#8225=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_60_57','Non-reflecting road studs',#8222,$,$); -#8226=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_60_62','Pedestrian delineation road studs',#8222,$,$); -#8227=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_60_71','Retroreflecting road studs',#8222,$,$); -#8228=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_60_77','Skateboard deterrent studs',#8222,$,$); -#8229=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_60_78','Slip-resistant cast inserts',#8222,$,$); -#8230=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_60_79','Slip-resistant rebate inserts',#8222,$,$); -#8231=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_60_87','Tactile paving studs',#8222,$,$); -#8232=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87','Tapes, strips and profile fillers',#8008,$,$); -#8233=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_01','Acrylic adhesive fixing tapes',#8232,$,$); -#8234=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_02','Acrylic adhesive sealant tapes',#8232,$,$); -#8235=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_03','Aluminium conductor tapes',#8232,$,$); -#8236=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_04','Aluminium foil tapes',#8232,$,$); -#8237=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_07','Butyl rubber adhesive tapes',#8232,$,$); -#8238=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_08','Butyl rubber preformed strips',#8232,$,$); -#8239=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_09','Butyl rubber sealant tapes',#8232,$,$); -#8240=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_10','Butyl rubber fleece tapes',#8232,$,$); -#8241=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_15','Copper conductor tapes',#8232,$,$); -#8242=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_23','Double-sided tape damp proof course joint sealers',#8232,$,$); -#8243=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_25','Ethylene propylene diene monomer (EPDM)-coated expanded polyethylene (PE) foam profile fillers',#8232,$,$); -#8244=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_26','Expanded polyethylene (PE) foam profile fillers',#8232,$,$); -#8245=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_27','Expanded polyethylene (PE) foam strips',#8232,$,$); -#8246=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_28','Expanded polystyrene (EPS) foam strips',#8232,$,$); -#8247=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_30','Fire-resistant glazing tapes',#8232,$,$); -#8248=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_31','Flash tapes',#8232,$,$); -#8249=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_34','Glass fibre mesh repair tapes',#8232,$,$); -#8250=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_37','Heat-bonded carpet tapes',#8232,$,$); -#8251=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_41','Intumescent tapes',#8232,$,$); -#8252=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_42','Isolating tapes',#8232,$,$); -#8253=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_52','Metal strip reinforced paper tapes',#8232,$,$); -#8254=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_53','Mineral fibre joint fillers',#8232,$,$); -#8255=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_54','Mineral fibre profile fillers',#8232,$,$); -#8256=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_56','Non-impregnated foam glazing tapes',#8232,$,$); -#8257=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_60','Paper jointing tapes',#8232,$,$); -#8258=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_64','Polyethylene (PE) debonding tapes',#8232,$,$); -#8259=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_66','Polytetrafluoroethylene (PTFE) tapes',#8232,$,$); -#8260=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_67','Pre-formed butyl shim glazing tapes',#8232,$,$); -#8261=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_71','Resin impregnated pre-compressed foam sealing strips',#8232,$,$); -#8262=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_72','Retroreflective self-adhesive tapes',#8232,$,$); -#8263=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_77','Self-adhesive bitumen tapes',#8232,$,$); -#8264=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_78','Self-adhesive sports marking tapes',#8232,$,$); -#8265=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_84','Structural glazing tapes',#8232,$,$); -#8266=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_85','Synthetic closed cell foam rubber profile fillers',#8232,$,$); -#8267=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_86','Synthetic rubber strips',#8232,$,$); -#8268=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_97','Water polo field marking lines',#8232,$,$); -#8269=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_98','Woven glass fibre fabric strips',#8232,$,$); -#8270=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93','Unit roofing fittings',#8008,$,$); -#8271=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_07','Bitumen membrane shingle cappings',#8270,$,$); -#8272=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_12','Clay tile hip fittings',#8270,$,$); -#8273=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_13','Clay tile ridge fittings',#8270,$,$); -#8274=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_14','Clay tile roof slope ventilation fittings',#8270,$,$); -#8275=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_15','Clay tile valley fittings',#8270,$,$); -#8276=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_16','Clay tile verge fittings',#8270,$,$); -#8277=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_19','Concrete tile hip fittings',#8270,$,$); -#8278=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_21','Concrete tile ridge fittings',#8270,$,$); -#8279=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_22','Concrete tile roof slope ventilation fittings',#8270,$,$); -#8280=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_23','Concrete tile valley fittings',#8270,$,$); -#8281=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_24','Concrete tile verge fittings',#8270,$,$); -#8282=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_26','Dentil slips',#8270,$,$); -#8283=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_27','Dry fixing abutments',#8270,$,$); -#8284=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_28','Dry fixing hips',#8270,$,$); -#8285=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_29','Dry fixing ridges',#8270,$,$); -#8286=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_30','Dry fixing verges',#8270,$,$); -#8287=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_32','Fibre-cement slate hip fittings',#8270,$,$); -#8288=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_33','Fibre-cement slate ridge fittings',#8270,$,$); -#8289=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_34','Fibre-cement slate roof slope ventilation fittings',#8270,$,$); -#8290=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_35','Fibre-cement slate verge fittings',#8270,$,$); -#8291=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_51','Metal tile hip fittings',#8270,$,$); -#8292=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_52','Metal tile ridge fittings',#8270,$,$); -#8293=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_53','Metal tile verge fittings',#8270,$,$); -#8294=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_72','Reconstituted slate roof slope ventilation fittings',#8270,$,$); -#8295=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_96','Wood shake fittings',#8270,$,$); -#8296=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_97','Wood shingle fittings',#8270,$,$); -#8297=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93','Unit covering and finish products',#7591,$,$); -#8298=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_13','Ceiling infill units',#8297,$,$); -#8299=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_13_13','Cement bonded wood wool infill units',#8298,$,$); -#8300=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_13_30','Fibre reinforced gypsum infill units',#8298,$,$); -#8301=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_13_51','Metal infill units',#8298,$,$); -#8302=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_13_53','Mineral fibre infill units',#8298,$,$); -#8303=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_13_58','Open cell infill units',#8298,$,$); -#8304=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_13_61','Panel diffuser infill units',#8298,$,$); -#8305=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_13_65','Profiled metal acoustic panels',#8298,$,$); -#8306=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_13_71','Resin bonded mineral wool infill units',#8298,$,$); -#8307=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_13_73','Rigid urethane foam infill units',#8298,$,$); -#8308=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_13_80','Sound attenuator infill units',#8298,$,$); -#8309=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_13_94','Veneered wood composite infill units',#8298,$,$); -#8310=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96','Wall and floor tile units',#8297,$,$); -#8311=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_10','Cast stone slabs',#8310,$,$); -#8312=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_11','Cast stone tiles',#8310,$,$); -#8313=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_12','Ceramic tile angle beads',#8310,$,$); -#8314=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_13','Ceramic tile borders',#8310,$,$); -#8315=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_14','Ceramic tile cove skirtings',#8310,$,$); -#8316=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_15','Ceramic tile floor channels',#8310,$,$); -#8317=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_16','Ceramic tile round edges',#8310,$,$); -#8318=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_17','Ceramic tile sit-on skirtings',#8310,$,$); -#8319=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_18','Ceramic tile step treads',#8310,$,$); -#8320=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_19','Ceramic tiles',#8310,$,$); -#8321=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_21','Concrete tiles',#8310,$,$); -#8322=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_34','Graphic-printed porcelain tiles',#8310,$,$); -#8323=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_53','Mosaic tiles',#8310,$,$); -#8324=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_56','Natural stone wall and floor slabs',#8310,$,$); -#8325=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_57','Natural stone tiles',#8310,$,$); -#8326=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_63','Porcelain tiles',#8310,$,$); -#8327=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_66','Quarry tile borders',#8310,$,$); -#8328=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_67','Quarry tile cove skirtings',#8310,$,$); -#8329=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_68','Quarry tile floor channels',#8310,$,$); -#8330=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_70','Quarry tile sit-on skirtings',#8310,$,$); -#8331=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_71','Quarry tile step treads',#8310,$,$); -#8332=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_72','Quarry tiles',#8310,$,$); -#8333=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_85','Stone slabs',#8310,$,$); -#8334=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_86','Stone tiles',#8310,$,$); -#8335=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_87','Tile matting',#8310,$,$); -#8336=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_88','Terrazzo precast units',#8310,$,$); -#8337=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_89','Terrazzo tile skirtings',#8310,$,$); -#8338=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_90','Terrazzo tiles',#8310,$,$); -#8339=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_92','Tile spacers',#8310,$,$); -#8340=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_97','Wood block units',#8297,$,$); -#8341=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_97_15','Composition blocks',#8340,$,$); -#8342=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_97_52','Mosaic panels',#8340,$,$); -#8343=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_97_96','Wood blocks',#8340,$,$); -#8344=IFCCLASSIFICATIONREFERENCE($,'Pr_40','Signage, sanitary fittings and fittings, furnishing and equipment (FF&E) products',#4921,$,$); -#8345=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10','Signage products',#8344,$,$); -#8346=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_27','Electrical services signs',#8345,$,$); -#8347=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_27_24','Electrical diagrams',#8346,$,$); -#8348=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_27_27','Electrical shock treatment signs',#8346,$,$); -#8349=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_27_28','Externally illuminated emergency exit signs',#8346,$,$); -#8350=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_27_43','Induction loop system signs',#8346,$,$); -#8351=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_27_62','Photoluminescent emergency signs',#8346,$,$); -#8352=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_27_63','Photoluminescent low mounted way-guidance lighting',#8346,$,$); -#8353=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_27_86','Surveillance system signs',#8346,$,$); -#8354=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_27_88','Telecommunications equipment and outlets labels',#8346,$,$); -#8355=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_27_91','Underground cable marker tapes',#8346,$,$); -#8356=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57','Notices, identification and labels',#8345,$,$); -#8357=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_10','Burnt clay warning marker tiles',#8356,$,$); -#8358=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_12','Cable marker tags',#8356,$,$); -#8359=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_15','Concrete warning marker tiles',#8356,$,$); -#8360=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_21','Door number labels',#8356,$,$); -#8361=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_24','Electrical identification labels',#8356,$,$); -#8362=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_26','Engraved mechanical plant and equipment identification labels',#8356,$,$); -#8363=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_27','Engraved valve charts and schematics',#8356,$,$); -#8364=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_28','Engraved valve identification labels',#8356,$,$); -#8365=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_29','Equipment labels and warning notices',#8356,$,$); -#8366=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_32','Fire hydrant indicator plates',#8356,$,$); -#8367=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_36','Heat shrink sleeves',#8356,$,$); -#8368=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_39','Images and logos',#8356,$,$); -#8369=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_40','Inclined stair lift notices',#8356,$,$); -#8370=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_50','Marker posts',#8356,$,$); -#8371=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_52','Metal ductwork labels',#8356,$,$); -#8372=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_56','Nail identification washers',#8356,$,$); -#8373=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_60','Paper valve charts and schematics',#8356,$,$); -#8374=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_63','Plants delivery labels',#8356,$,$); -#8375=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_64','Plants permanent labels',#8356,$,$); -#8376=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_65','Plastics ductwork labels',#8356,$,$); -#8377=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_66','Plastics warning marker boards',#8356,$,$); -#8378=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_67','Platform lift notices',#8356,$,$); -#8379=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_71','Room name labels',#8356,$,$); -#8380=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_72','Room number labels',#8356,$,$); -#8381=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_76','Screen-printed mechanical plant and equipment identification labels',#8356,$,$); -#8382=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_77','Screen-printed valve identification labels',#8356,$,$); -#8383=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_78','Self-adhesive colour pipe bands',#8356,$,$); -#8384=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_79','Self-adhesive plastics ductwork labels and transfers',#8356,$,$); -#8385=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_96','Warning marker tapes',#8356,$,$); -#8386=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_97','Warning marker tiles',#8356,$,$); -#8387=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_98','Water firefighting system identification and labels',#8356,$,$); -#8388=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_99','Window number labels',#8356,$,$); -#8389=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77','Signs and markers',#8345,$,$); -#8390=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_02','\X2\2018\X0\A\X2\2019\X0\ boards',#8389,$,$); -#8391=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_04','Alpha numeric characters',#8389,$,$); -#8392=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_05','Applied glazing details',#8389,$,$); -#8393=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_06','Banner signs',#8389,$,$); -#8394=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_07','Beach safety flags',#8389,$,$); -#8395=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_08','Braille signs',#8389,$,$); -#8396=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_11','Cabinet signs',#8389,$,$); -#8397=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_20','Datum plates and markers',#8389,$,$); -#8398=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_22','Designation signs',#8389,$,$); -#8399=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_24','Directory signs',#8389,$,$); -#8400=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_27','Evacuation signs',#8389,$,$); -#8401=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_29','Fencing safety reflectors',#8389,$,$); -#8402=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_30','Finger signs',#8389,$,$); -#8403=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_31','Fire equipment signs',#8389,$,$); -#8404=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_32','Fire escape route signs',#8389,$,$); -#8405=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_36','Hazard delineators',#8389,$,$); -#8406=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_37','Highway marker posts',#8389,$,$); -#8407=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_38','Hoarding signs',#8389,$,$); -#8408=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_41','Illuminated signs',#8389,$,$); -#8409=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_42','Individual letter signs',#8389,$,$); -#8410=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_46','Ladder signs',#8389,$,$); -#8411=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_50','Mandatory action signs',#8389,$,$); -#8412=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_52','Monolith signs',#8389,$,$); -#8413=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_53','Moving signs',#8389,$,$); -#8414=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_56','Nameplates',#8389,$,$); -#8415=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_61','Phosphorescent way guidance tapes',#8389,$,$); -#8416=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_63','Plaques',#8389,$,$); -#8417=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_64','Platform lift signs',#8389,$,$); -#8418=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_66','Prohibition signs',#8389,$,$); -#8419=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_69','Public access stair lift signs',#8389,$,$); -#8420=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_70','Railway signs',#8389,$,$); -#8421=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_72','Road traffic signs',#8389,$,$); -#8422=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_74','Safety equipment signs',#8389,$,$); -#8423=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_75','Safe condition signs',#8389,$,$); -#8424=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_76','Safety signs',#8389,$,$); -#8425=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_77','Signboards',#8389,$,$); -#8426=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_79','Sliding cover signs',#8389,$,$); -#8427=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_82','Stair lift signs',#8389,$,$); -#8428=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_84','Street sign plates',#8389,$,$); -#8429=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_85','Street signs',#8389,$,$); -#8430=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_86','Survey markers',#8389,$,$); -#8431=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_88','Toposcopes',#8389,$,$); -#8432=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_89','Traffic cones',#8389,$,$); -#8433=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_90','Traffic cylinders',#8389,$,$); -#8434=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_92','Variable message signs',#8389,$,$); -#8435=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_94','Verge markers',#8389,$,$); -#8436=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_96','Warning markers',#8389,$,$); -#8437=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_97','Warning signs',#8389,$,$); -#8438=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_98','Waymarker discs',#8389,$,$); -#8439=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_99','Waymarker posts',#8389,$,$); -#8440=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_90','Water and navigation aid signs',#8345,$,$); -#8441=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_90_07','Beacons',#8440,$,$); -#8442=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_90_10','Buoys',#8440,$,$); -#8443=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_90_31','Fog signals',#8440,$,$); -#8444=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_90_50','Marine traffic signals',#8440,$,$); -#8445=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_90_56','Navigation signs',#8440,$,$); -#8446=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_96','Wind direction indicator products',#8345,$,$); -#8447=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_96_96','Weathervanes',#8446,$,$); -#8448=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_96_98','Windsocks',#8446,$,$); -#8449=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20','Sanitary fittings and accessories',#8344,$,$); -#8450=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_06','Bathing fittings',#8449,$,$); -#8451=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_06_02','Accessible baths',#8450,$,$); -#8452=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_06_08','Baths',#8450,$,$); -#8453=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_06_11','Bidets',#8450,$,$); -#8454=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_06_36','Health care general baths',#8450,$,$); -#8455=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_06_38','Hospital pattern bidets',#8450,$,$); -#8456=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_06_79','Shower enclosures',#8450,$,$); -#8457=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_06_83','Shower seats',#8450,$,$); -#8458=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_06_84','Shower trays',#8450,$,$); -#8459=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_06_99','Whirlpool baths',#8450,$,$); -#8460=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_27','Emergency shower products',#8449,$,$); -#8461=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_27_15','Combined emergency shower and eye wash stations',#8460,$,$); -#8462=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_27_28','Eye wash fountains',#8460,$,$); -#8463=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_27_75','Safety showers',#8460,$,$); -#8464=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_60','Packaged sanitary fittings',#8449,$,$); -#8465=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_60_02','Accessible WC equipment packages',#8464,$,$); -#8466=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_60_75','Sauna room packages',#8464,$,$); -#8467=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_60_78','Shower enclosure packages',#8464,$,$); -#8468=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_60_85','Steam cabinet packages',#8464,$,$); -#8469=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_60_86','Steam room packages',#8464,$,$); -#8470=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_60_96','Wet room floor formers',#8464,$,$); -#8471=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76','Sanitary accessories',#8449,$,$); -#8472=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_01','Adult changing units',#8471,$,$); -#8473=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_02','Air fresheners',#8471,$,$); -#8474=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_06','Baby changing units',#8471,$,$); -#8475=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_07','Bath panels',#8471,$,$); -#8476=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_82','Soap dishes',#8471,$,$); -#8477=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_83','Splashbacks',#8471,$,$); -#8478=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_84','Support rails',#8471,$,$); -#8479=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_86','Toilet brush holders',#8471,$,$); -#8480=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_88','Toilet roll holders',#8471,$,$); -#8481=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_89','Toothbrush holders',#8471,$,$); -#8482=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_90','Towel rails',#8471,$,$); -#8483=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_91','Towel rings',#8471,$,$); -#8484=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_92','Tumbler holders',#8471,$,$); -#8485=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_94','Vanity units',#8471,$,$); -#8486=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_98','WC pan backrests',#8471,$,$); -#8487=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87','Taps and water supply outlet fittings',#8449,$,$); -#8488=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_07','Bath manual water supply sets',#8487,$,$); -#8489=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_08','Bath spouts',#8487,$,$); -#8490=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_09','Bath taps',#8487,$,$); -#8491=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_10','Bath thermostatic water supply sets',#8487,$,$); -#8492=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_11','Bidet taps',#8487,$,$); -#8493=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_31','Foot-operated valves',#8487,$,$); -#8494=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_33','Garden taps',#8487,$,$); -#8495=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_35','Grip valves',#8487,$,$); -#8496=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_43','Key-operated valves',#8487,$,$); -#8497=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_49','Knee-operated valves',#8487,$,$); -#8498=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_75','Shower fittings package',#8487,$,$); -#8499=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_76','Shower heads',#8487,$,$); -#8500=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_77','Shower head holders',#8487,$,$); -#8501=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_78','Shower manual water supply sets',#8487,$,$); -#8502=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_79','Shower self-closing (emergency) valves',#8487,$,$); -#8503=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_80','Shower thermostatic valves',#8487,$,$); -#8504=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_81','Shower thermostatic water supply sets',#8487,$,$); -#8505=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_82','Sink manual water supply sets',#8487,$,$); -#8506=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_83','Sink spouts',#8487,$,$); -#8507=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_84','Sink taps',#8487,$,$); -#8508=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_85','Sink thermostatic water supply sets',#8487,$,$); -#8509=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_89','Toilet showers',#8487,$,$); -#8510=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_96','Washbasin manual water supply sets',#8487,$,$); -#8511=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_97','Washbasin spouts',#8487,$,$); -#8512=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_98','Washbasin taps',#8487,$,$); -#8513=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_99','Washbasin thermostatic water supply sets',#8487,$,$); -#8514=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93','Urinal and WC fittings',#8449,$,$); -#8515=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_30','Floor standing urinals',#8514,$,$); -#8516=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_36','Health care macerators',#8514,$,$); -#8517=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_37','Hospital pattern disposal units',#8514,$,$); -#8518=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_38','Hospital pattern urinals',#8514,$,$); -#8519=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_39','Hospital pattern WC pans and cisterns',#8514,$,$); -#8520=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_62','Pre-plumbed installation frames',#8514,$,$); -#8521=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_74','Urinal dividers',#8514,$,$); -#8522=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_77','Slab urinals',#8514,$,$); -#8523=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_78','Urinal cisterns',#8514,$,$); -#8524=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_79','Urinal flushing valves',#8514,$,$); -#8525=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_80','Urinal flush pipes',#8514,$,$); -#8526=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_82','Wall-hung urinals',#8514,$,$); -#8527=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_84','Waterless urinals',#8514,$,$); -#8528=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_85','Waterless toilets',#8514,$,$); -#8529=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_86','WC and washbasin combined units',#8514,$,$); -#8530=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_87','WC cistern fittings',#8514,$,$); -#8531=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_89','WC cisterns',#8514,$,$); -#8532=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_90','WC cistern flush pipes',#8514,$,$); -#8533=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_91','WC flushing valves',#8514,$,$); -#8534=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_92','WC large capacity replacement cisterns',#8514,$,$); -#8535=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_93','WC pan connectors',#8514,$,$); -#8536=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_94','WC pans',#8514,$,$); -#8537=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_95','WC seats and covers',#8514,$,$); -#8538=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_96','WC squatting pans',#8514,$,$); -#8539=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_97','WC suites',#8514,$,$); -#8540=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_99','WC, wash and dry combined units',#8514,$,$); -#8541=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96','Wash basins, sinks and troughs',#8449,$,$); -#8542=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_15','Ceramic sinks',#8541,$,$); -#8543=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_17','Commercial kitchen rinsing sinks',#8541,$,$); -#8544=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_18','Counter top wash basins',#8541,$,$); -#8545=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_34','Health care clinical sinks with drainers',#8541,$,$); -#8546=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_35','Health care clinical wash basins',#8541,$,$); -#8547=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_36','Health care domestic service sinks',#8541,$,$); -#8548=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_37','Health care general wash basins',#8541,$,$); -#8549=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_38','Health care hand rinse basins',#8541,$,$); -#8550=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_39','Hospital pattern plaster sinks',#8541,$,$); -#8551=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_40','Hospital pattern scrub-up troughs',#8541,$,$); -#8552=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_42','Integral wash basins and vanity tops',#8541,$,$); -#8553=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_44','Janitorial sinks',#8541,$,$); -#8554=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_45','Kitchen sinks',#8541,$,$); -#8555=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_46','Laundry troughs',#8541,$,$); -#8556=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_47','Laundry troughs and cabinets',#8541,$,$); -#8557=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_63','Pedestal wash basins',#8541,$,$); -#8558=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_70','Recessed wash basins',#8541,$,$); -#8559=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_81','Sinks',#8541,$,$); -#8560=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_92','Undermounted wash basins',#8541,$,$); -#8561=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_95','Wall-hung hand rinse basins',#8541,$,$); -#8562=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_96','Wall-hung wash basins',#8541,$,$); -#8563=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_99','Wash troughs',#8541,$,$); -#8564=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30','Fittings',#8344,$,$); -#8565=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04','Animal housing',#8564,$,$); -#8566=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04_02','Animal feeding stations',#8565,$,$); -#8567=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04_06','Bat boxes',#8565,$,$); -#8568=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04_07','Bird baths',#8565,$,$); -#8569=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04_08','Bird boxes',#8565,$,$); -#8570=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04_09','Bird roosts',#8565,$,$); -#8571=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04_15','Columbaria',#8565,$,$); -#8572=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04_24','Dog kennels',#8565,$,$); -#8573=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04_25','Dovecotes',#8565,$,$); -#8574=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04_41','Insect houses',#8565,$,$); -#8575=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04_50','Mammal houses',#8565,$,$); -#8576=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04_56','Nesting baskets',#8565,$,$); -#8577=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04_57','Nest poles and platforms',#8565,$,$); -#8578=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04_70','Raptor poles',#8565,$,$); -#8579=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20','Curtains and screens',#8564,$,$); -#8580=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_02','Acoustic curtains',#8579,$,$); -#8581=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_03','Acoustic screens',#8579,$,$); -#8582=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_13','Choir screens',#8579,$,$); -#8583=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_38','Hospital bed screens',#8579,$,$); -#8584=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_58','Organ screens',#8579,$,$); -#8585=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_59','Ornamental screens',#8579,$,$); -#8586=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_63','Privacy curtain supports',#8579,$,$); -#8587=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_64','Privacy curtains',#8579,$,$); -#8588=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_65','Privacy screens',#8579,$,$); -#8589=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_67','Polyvinyl chloride (PVC) strip curtains',#8579,$,$); -#8590=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_70','Recessed curtain pelmets',#8579,$,$); -#8591=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_71','Relaxation screens',#8579,$,$); -#8592=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_77','Shower curtain rails',#8579,$,$); -#8593=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_78','Shower curtains',#8579,$,$); -#8594=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_83','Stage curtain supports',#8579,$,$); -#8595=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_84','Stage curtains',#8579,$,$); -#8596=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_86','Surface mounted curtain pelmets',#8579,$,$); -#8597=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_96','Window curtain supports',#8579,$,$); -#8598=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_97','Window curtains',#8579,$,$); -#8599=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_21','Cycle stands and lockers',#8564,$,$); -#8600=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_21_02','Aluminium cycle lockers',#8599,$,$); -#8601=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_21_11','Carbon steel cycle lockers',#8599,$,$); -#8602=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_21_12','Carbon steel cycle stands',#8599,$,$); -#8603=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_21_13','Ceiling-mounted cycle supports',#8599,$,$); -#8604=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_21_35','Ground-mounted cycle stands',#8599,$,$); -#8605=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_21_36','Hardwood cycle stands',#8599,$,$); -#8606=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_21_65','Plastics cycle lockers',#8599,$,$); -#8607=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_21_83','Stainless steel cycle lockers',#8599,$,$); -#8608=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_21_84','Stainless steel cycle stands',#8599,$,$); -#8609=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_21_96','Wall-mounted cycle stands',#8599,$,$); -#8610=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22','Deterrents and traps',#8564,$,$); -#8611=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_02','Animal deterrents',#8610,$,$); -#8612=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_05','Bait stations',#8610,$,$); -#8613=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_06','Bird deterrent spikes',#8610,$,$); -#8614=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_11','Cage traps',#8610,$,$); -#8615=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_14','Coiled wire bird deterrents',#8610,$,$); -#8616=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_22','Decoy predators',#8610,$,$); -#8617=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_26','Electric pulse tactile/track bird deterrents',#8610,$,$); -#8618=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_30','Flight diverters',#8610,$,$); -#8619=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_31','Frond bird deterrents',#8610,$,$); -#8620=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_34','Guard barriers',#8610,$,$); -#8621=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_38','Humane traps',#8610,$,$); -#8622=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_40','Inclined surface bird deterrents',#8610,$,$); -#8623=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_46','Laser bird repellers',#8610,$,$); -#8624=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_48','Low tension wire bird (gull) deterrents',#8610,$,$); -#8625=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_56','Non-toxic rat and mouse baits',#8610,$,$); -#8626=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_60','Pheromone traps',#8610,$,$); -#8627=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_64','Powered traps',#8610,$,$); -#8628=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_66','Powered ultraviolet light traps',#8610,$,$); -#8629=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_76','Scare eyes',#8610,$,$); -#8630=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_80','Sonic deterrents',#8610,$,$); -#8631=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_82','Spring traps',#8610,$,$); -#8632=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_84','Sprung tension wire bird deterrents',#8610,$,$); -#8633=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_87','Tactile gels and liquids deterrents',#8610,$,$); -#8634=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_89','Taste and scent bird deterrents',#8610,$,$); -#8635=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_92','Ultrasonic rodent repellers',#8610,$,$); -#8636=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_95','Vision disturbance bird deterrents',#8610,$,$); -#8637=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_96','Visual threat bird deterrents',#8610,$,$); -#8638=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25','Display and presentation fittings',#8564,$,$); -#8639=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_03','Audible signs',#8638,$,$); -#8640=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_04','Audio visual furniture',#8638,$,$); -#8641=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_13','Chalkboards',#8638,$,$); -#8642=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_17','Computer generated signs',#8638,$,$); -#8643=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_21','Demountable podiums and staging',#8638,$,$); -#8644=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_22','Desktop lecterns',#8638,$,$); -#8645=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_23','Display screens',#8638,$,$); -#8646=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_25','Dot matrix displays',#8638,$,$); -#8647=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_30','Freestanding screens',#8638,$,$); -#8648=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_42','Interactive whiteboards',#8638,$,$); -#8649=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_46','Lecterns',#8638,$,$); -#8650=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_47','Light emitting diode (LED) panels',#8638,$,$); -#8651=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_48','Liquid crystal display (LCD) panels',#8638,$,$); -#8652=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_50','Magnetic boards',#8638,$,$); -#8653=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_55','Multimedia screens',#8638,$,$); -#8654=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_58','Notice boards',#8638,$,$); -#8655=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_64','Pinboards',#8638,$,$); -#8656=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_65','Plasma display screens',#8638,$,$); -#8657=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_67','Projection screens',#8638,$,$); -#8658=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_71','Retail display fittings',#8638,$,$); -#8659=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_88','Teaching walls',#8638,$,$); -#8660=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_96','Whiteboards',#8638,$,$); -#8661=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_26','Drying lines',#8564,$,$); -#8662=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_26_12','Ceiling mounted clothes-drying lines',#8661,$,$); -#8663=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_26_30','Folding wall mounted clothes-drying lines',#8661,$,$); -#8664=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_26_32','Free standing clothes-drying lines',#8661,$,$); -#8665=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_26_55','Multiple line retractable clothes-drying lines',#8661,$,$); -#8666=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_26_63','Photographic film-drying lines',#8661,$,$); -#8667=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_26_65','Portable clothes-drying lines',#8661,$,$); -#8668=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_26_72','Rotary clothes-drying lines',#8661,$,$); -#8669=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_26_79','Single line retractable clothes-drying lines',#8661,$,$); -#8670=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29','Fitted chairs, seats and benches',#8564,$,$); -#8671=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_05','Auditorium seating',#8670,$,$); -#8672=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_12','Choir seating',#8670,$,$); -#8673=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_13','Choir stalls',#8670,$,$); -#8674=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_22','Demountable seats',#8670,$,$); -#8675=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_29','Fixed seats',#8670,$,$); -#8676=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_31','Fixed observation poolside chairs',#8670,$,$); -#8677=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_46','Leaning rails',#8670,$,$); -#8678=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_61','Pedicure chairs',#8670,$,$); -#8679=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_72','Retractable seats',#8670,$,$); -#8680=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_79','Sitting rails',#8670,$,$); -#8681=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_83','Spa foot ritual benches',#8670,$,$); -#8682=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_84','Street and site benches',#8670,$,$); -#8683=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_85','Street and site seats',#8670,$,$); -#8684=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_88','Thrones',#8670,$,$); -#8685=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_96','Wall-fixed lift-up seats',#8670,$,$); -#8686=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_97','Wall-mounted gallery benches',#8670,$,$); -#8687=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_98','Window seats',#8670,$,$); -#8688=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30','Fitted desks, tables and worktops',#8564,$,$); -#8689=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_18','Counter tops',#8688,$,$); -#8690=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_22','Dishwasher inlet tables',#8688,$,$); -#8691=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_23','Dishwasher outlet tables',#8688,$,$); -#8692=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_32','Food preparation worktops',#8688,$,$); -#8693=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_42','Industrial work benches',#8688,$,$); -#8694=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_45','Kitchen splashbacks',#8688,$,$); -#8695=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_47','Laboratory work benches',#8688,$,$); -#8696=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_48','Laboratory worktops',#8688,$,$); -#8697=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_62','Picnic tables',#8688,$,$); -#8698=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_71','Reception desks',#8688,$,$); -#8699=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_78','School art, design and technology work benches',#8688,$,$); -#8700=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_79','Servery counters',#8688,$,$); -#8701=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_80','Sink tables',#8688,$,$); -#8702=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_86','Street and site tables',#8688,$,$); -#8703=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_96','Worktops',#8688,$,$); -#8704=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_31','Flagpoles',#8564,$,$); -#8705=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_31_29','Fan-assisted ground-mounted flagpoles',#8704,$,$); -#8706=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_31_33','Ground-mounted banner poles',#8704,$,$); -#8707=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_31_34','Ground-mounted flagpoles',#8704,$,$); -#8708=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_31_35','Ground-mounted sleeved flagpoles',#8704,$,$); -#8709=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_31_53','Mobile telescopic flagpoles',#8704,$,$); -#8710=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_31_70','Rigged and guyed flagpoles',#8704,$,$); -#8711=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_31_71','Rigged un-guyed flagpoles',#8704,$,$); -#8712=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_31_96','Wall-mounted flagpoles',#8704,$,$); -#8713=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_50','Mail fittings',#8564,$,$); -#8714=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_50_46','Letter boxes',#8713,$,$); -#8715=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_50_47','Letter cages',#8713,$,$); -#8716=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_50_48','Letter plate internal flaps and seals',#8713,$,$); -#8717=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_50_49','Letter plates',#8713,$,$); -#8718=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_50_62','Pigeonholes',#8713,$,$); -#8719=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_50_65','Post boxes',#8713,$,$); -#8720=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_55','Musical instruments',#8564,$,$); -#8721=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_55_06','Bell frames',#8720,$,$); -#8722=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_55_07','Bell headstocks',#8720,$,$); -#8723=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_55_08','Bell wheels',#8720,$,$); -#8724=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_55_10','Bracket bells',#8720,$,$); -#8725=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_55_77','Ship\X2\2019\X0\s bells',#8720,$,$); -#8726=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_55_89','Tower bells',#8720,$,$); -#8727=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_55_90','Tubular bells',#8720,$,$); -#8728=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_55_91','Turret bells',#8720,$,$); -#8729=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61','Play equipment',#8564,$,$); -#8730=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_15','Climbing frames',#8729,$,$); -#8731=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_18','Combined play structures',#8729,$,$); -#8732=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_40','Imaginative play structures',#8729,$,$); -#8733=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_42','Infants'' swings',#8729,$,$); -#8734=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_52','Modular play climbers',#8729,$,$); -#8735=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_61','Play panels',#8729,$,$); -#8736=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_62','Play pools',#8729,$,$); -#8737=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_63','Play roundabouts',#8729,$,$); -#8738=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_64','Play runways',#8729,$,$); -#8739=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_65','Play sandpits',#8729,$,$); -#8740=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_66','Play slides',#8729,$,$); -#8741=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_67','Play swings',#8729,$,$); -#8742=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_77','See-saws',#8729,$,$); -#8743=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_78','Sensory play structures',#8729,$,$); -#8744=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_79','Sit-on rockers',#8729,$,$); -#8745=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_82','Spinning poles',#8729,$,$); -#8746=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_88','Traditional rockers',#8729,$,$); -#8747=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_95','Water play equipment',#8729,$,$); -#8748=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_96','Water play fountains',#8729,$,$); -#8749=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_97','Water play structures',#8729,$,$); -#8750=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_98','Wobble boards',#8729,$,$); -#8751=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_65','Point of sale fittings',#8564,$,$); -#8752=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_65_11','Cash registers',#8751,$,$); -#8753=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_65_12','Cash transfer units',#8751,$,$); -#8754=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_65_13','Cashier drawers',#8751,$,$); -#8755=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_65_60','Paystations and troughs',#8751,$,$); -#8756=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_65_65','Point of sale units',#8751,$,$); -#8757=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_65_88','Tills',#8751,$,$); -#8758=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_66','Poster display units',#8564,$,$); -#8759=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_66_22','Digital poster display units',#8758,$,$); -#8760=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_66_73','Rolling poster display units',#8758,$,$); -#8761=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_66_74','Rotating poster display units',#8758,$,$); -#8762=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_66_84','Static poster display units',#8758,$,$); -#8763=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_71','Religious fittings',#8564,$,$); -#8764=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_71_01','Abats-voix',#8763,$,$); -#8765=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_71_03','Ambons',#8763,$,$); -#8766=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_71_06','Baldachins',#8763,$,$); -#8767=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_71_07','Bimahs',#8763,$,$); -#8768=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_71_31','Fonts',#8763,$,$); -#8769=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_71_36','Hassocks',#8763,$,$); -#8770=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_71_51','Minbars',#8763,$,$); -#8771=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_71_56','Nave lecterns',#8763,$,$); -#8772=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_71_68','Pulpits',#8763,$,$); -#8773=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75','Safes and security cabinets',#8564,$,$); -#8774=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_11','Cash safes',#8773,$,$); -#8775=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_16','Computer safes',#8773,$,$); -#8776=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_20','Cupboard safes',#8773,$,$); -#8777=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_21','Data protection safes',#8773,$,$); -#8778=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_22','Deposit safes',#8773,$,$); -#8779=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_29','Fire protection safes',#8773,$,$); -#8780=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_30','Firearm security cabinets',#8773,$,$); -#8781=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_31','Floorboard safes',#8773,$,$); -#8782=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_36','High security safes',#8773,$,$); -#8783=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_38','Home and office safes',#8773,$,$); -#8784=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_39','Hotel safes',#8773,$,$); -#8785=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_45','Key safes',#8773,$,$); -#8786=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_49','Lead security cabinets',#8773,$,$); -#8787=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_51','Medical safes',#8773,$,$); -#8788=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_55','Multi-purpose security cabinets',#8773,$,$); -#8789=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_60','Parcel safes',#8773,$,$); -#8790=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_63','Plate safes',#8773,$,$); -#8791=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_76','Secure rooms',#8773,$,$); -#8792=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_84','Steel security cabinets',#8773,$,$); -#8793=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_90','Tool vaults',#8773,$,$); -#8794=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_93','Underfloor safes',#8773,$,$); -#8795=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_94','Vault doors',#8773,$,$); -#8796=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_96','Wall safes',#8773,$,$); -#8797=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78','Shelves and storage units',#8564,$,$); -#8798=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_01','Airing cabinets',#8797,$,$); -#8799=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_02','Archive shelves',#8797,$,$); -#8800=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_03','Bathroom cabinets',#8797,$,$); -#8801=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_05','Bathroom furniture',#8797,$,$); -#8802=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_06','Bathroom shelves',#8797,$,$); -#8803=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_07','Bedside units',#8797,$,$); -#8804=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_08','Bottle racks',#8797,$,$); -#8805=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_09','Bowl and bucket holders',#8797,$,$); -#8806=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_11','Chests',#8797,$,$); -#8807=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_12','Classroom storage units',#8797,$,$); -#8808=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_13','Cloakroom units',#8797,$,$); -#8809=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_14','Clothes drying cabinets',#8797,$,$); -#8810=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_15','Clothes hooks',#8797,$,$); -#8811=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_16','Coat hooks',#8797,$,$); -#8812=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_17','Coat racks',#8797,$,$); -#8813=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_18','College bedroom shelves',#8797,$,$); -#8814=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_19','Commercial kitchen shelving and racking units',#8797,$,$); -#8815=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_20','Copyholders',#8797,$,$); -#8816=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_21','Couch roll holders',#8797,$,$); -#8817=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_22','Credenzas',#8797,$,$); -#8818=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_23','Desk tidies',#8797,$,$); -#8819=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_24','Display cases',#8797,$,$); -#8820=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_25','Drawer units',#8797,$,$); -#8821=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_26','Dressers',#8797,$,$); -#8822=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_27','Equipment storage racks',#8797,$,$); -#8823=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_28','External storage units',#8797,$,$); -#8824=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_29','Filing cabinets',#8797,$,$); -#8825=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_30','Folding tables storage cabinets',#8797,$,$); -#8826=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_33','Glazed bookcases',#8797,$,$); -#8827=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_40','Index storage units',#8797,$,$); -#8828=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_41','In-the-round display cases',#8797,$,$); -#8829=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_42','Kitchen drawer units',#8797,$,$); -#8830=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_43','Kitchen bench cupboards',#8797,$,$); -#8831=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_44','Kitchen overhead cupboards',#8797,$,$); -#8832=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_45','Kitchen storage units',#8797,$,$); -#8833=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_46','Laboratory storage units',#8797,$,$); -#8834=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_47','Library shelf units',#8797,$,$); -#8835=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_48','Lockers',#8797,$,$); -#8836=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_51','Media wall partition units',#8797,$,$); -#8837=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_53','Movable aisle storage units',#8797,$,$); -#8838=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_55','Museum showcases',#8797,$,$); -#8839=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_57','Office storage units',#8797,$,$); -#8840=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_58','Open bookcases',#8797,$,$); -#8841=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_63','Plan chests',#8797,$,$); -#8842=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_65','Post room racks',#8797,$,$); -#8843=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_70','Refrigerated mortuary storage units',#8797,$,$); -#8844=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_71','Retail shelf units',#8797,$,$); -#8845=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_72','Retail storage units',#8797,$,$); -#8846=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_73','Rotary storage units',#8797,$,$); -#8847=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_76','Security cages',#8797,$,$); -#8848=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_77','Shelf units',#8797,$,$); -#8849=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_78','Shelves',#8797,$,$); -#8850=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_79','Shelf and racking units',#8797,$,$); -#8851=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_80','Shoe trees',#8797,$,$); -#8852=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_81','Sideboards',#8797,$,$); -#8853=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_84','Storage carousels',#8797,$,$); -#8854=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_85','Storage chests',#8797,$,$); -#8855=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_86','Storage wall partition units',#8797,$,$); -#8856=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_87','Suspension storage units',#8797,$,$); -#8857=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_88','Table storage credenzas',#8797,$,$); -#8858=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_90','Tool chests',#8797,$,$); -#8859=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_93','Under-bed storage units',#8797,$,$); -#8860=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_95','Wardrobe rails',#8797,$,$); -#8861=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_96','Wardrobes',#8797,$,$); -#8862=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_97','Weights storage racks',#8797,$,$); -#8863=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_80','Skateboard installations',#8564,$,$); -#8864=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_80_75','Skate bowls',#8863,$,$); -#8865=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_80_77','Skate edges',#8863,$,$); -#8866=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_80_78','Skate pipes',#8863,$,$); -#8867=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_80_80','Skate platforms',#8863,$,$); -#8868=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_80_81','Skate rails',#8863,$,$); -#8869=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_80_82','Skate ramps',#8863,$,$); -#8870=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_80_83','Skate stairs',#8863,$,$); -#8871=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_83','Sports fittings',#8564,$,$); -#8872=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_83_08','Basketball hoops',#8871,$,$); -#8873=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_83_10','Bouldering holds',#8871,$,$); -#8874=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_83_11','Bouldering walls',#8871,$,$); -#8875=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_83_14','Climbing walls',#8871,$,$); -#8876=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_83_37','Hanging and stretching equipment',#8871,$,$); -#8877=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84','Sports goals',#8564,$,$); -#8878=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_04','American football goal posts',#8877,$,$); -#8879=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_05','Australian football goal posts',#8877,$,$); -#8880=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_28','Five-a-side football goals',#8877,$,$); -#8881=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_29','Fixed water polo goals',#8877,$,$); -#8882=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_30','Floating water polo goals',#8877,$,$); -#8883=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_31','Football goals',#8877,$,$); -#8884=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_33','Gaelic football goal posts',#8877,$,$); -#8885=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_36','Handball goals',#8877,$,$); -#8886=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_39','Hockey goals',#8877,$,$); -#8887=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_40','Ice hockey goals',#8877,$,$); -#8888=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_46','Lacrosse goals',#8877,$,$); -#8889=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_56','Netball goals',#8877,$,$); -#8890=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_65','Polo goal posts',#8877,$,$); -#8891=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_69','Quidditch goals',#8877,$,$); -#8892=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_74','Rugby goal posts',#8877,$,$); -#8893=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_85','Sports netting',#8564,$,$); -#8894=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_85_04','Archery nets',#8893,$,$); -#8895=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_85_06','Badminton nets',#8893,$,$); -#8896=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_85_17','Cricket nets',#8893,$,$); -#8897=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_85_24','Driving range nets',#8893,$,$); -#8898=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_85_34','Golf course nets',#8893,$,$); -#8899=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_85_80','Space nets',#8893,$,$); -#8900=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_85_85','Stadium nets',#8893,$,$); -#8901=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_85_87','Tennis nets',#8893,$,$); -#8902=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_85_95','Volleyball nets',#8893,$,$); -#8903=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86','Swimming pool fittings',#8564,$,$); -#8904=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86_22','Diving platforms',#8903,$,$); -#8905=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86_24','Diving springboards',#8903,$,$); -#8906=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86_28','False start posts',#8903,$,$); -#8907=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86_30','Fixed domestic diving boards',#8903,$,$); -#8908=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86_32','Fixed starting platforms',#8903,$,$); -#8909=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86_47','Lane rope storage floor cover plates',#8903,$,$); -#8910=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86_59','Pool rails',#8903,$,$); -#8911=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86_78','Small water flumes',#8903,$,$); -#8912=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86_80','Small water slides',#8903,$,$); -#8913=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86_88','Touch panels',#8903,$,$); -#8914=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86_90','Turning boards',#8903,$,$); -#8915=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86_95','Water polo catwalks',#8903,$,$); -#8916=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86_96','Water polo field markers',#8903,$,$); -#8917=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50','Furnishings',#8344,$,$); -#8918=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05','Artworks',#8917,$,$); -#8919=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_02','Acrylic paintings',#8918,$,$); -#8920=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_11','Carvings',#8918,$,$); -#8921=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_13','Chalk drawings',#8918,$,$); -#8922=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_14','Charcoal drawings',#8918,$,$); -#8923=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_24','Drypoint prints',#8918,$,$); -#8924=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_27','Embroideries',#8918,$,$); -#8925=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_28','Etchings',#8918,$,$); -#8926=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_29','Floor-mounted mobiles',#8918,$,$); -#8927=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_30','Floor-mounted sculptures',#8918,$,$); -#8928=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_33','Garden ornaments',#8918,$,$); -#8929=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_41','Indoor ornaments',#8918,$,$); -#8930=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_42','Installation pieces',#8918,$,$); -#8931=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_43','Interactive artworks',#8918,$,$); -#8932=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_46','Linoprints',#8918,$,$); -#8933=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_51','Mixed media artworks',#8918,$,$); -#8934=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_55','Murals',#8918,$,$); -#8935=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_58','Oil paintings',#8918,$,$); -#8936=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_60','Pastel drawings',#8918,$,$); -#8937=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_62','Pencil drawings',#8918,$,$); -#8938=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_66','Projected artworks',#8918,$,$); -#8939=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_76','Screenprints',#8918,$,$); -#8940=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_77','Sculptural reliefs',#8918,$,$); -#8941=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_82','Sons et lumi\X2\00E9\X0\res',#8918,$,$); -#8942=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_84','Stand-mounted sculptures',#8918,$,$); -#8943=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_85','Statuary',#8918,$,$); -#8944=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_86','Suspended mobiles',#8918,$,$); -#8945=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_87','Tapestries',#8918,$,$); -#8946=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_95','Wall hangings',#8918,$,$); -#8947=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_96','Wall-mounted sculptures',#8918,$,$); -#8948=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_97','Watercolour paintings',#8918,$,$); -#8949=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06','Beds',#8917,$,$); -#8950=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_10','Bunk beds',#8949,$,$); -#8951=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_11','Camp beds',#8949,$,$); -#8952=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_14','Chair beds',#8949,$,$); -#8953=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_16','Cots',#8949,$,$); -#8954=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_18','Cradles',#8949,$,$); -#8955=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_22','Divans',#8949,$,$); -#8956=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_24','Double beds',#8949,$,$); -#8957=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_30','Foldaway beds',#8949,$,$); -#8958=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_31','Four-poster beds',#8949,$,$); -#8959=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_32','Futons',#8949,$,$); -#8960=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_36','Hammocks',#8949,$,$); -#8961=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_37','Headboards',#8949,$,$); -#8962=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_38','Hospital bedheads',#8949,$,$); -#8963=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_39','Hospital beds',#8949,$,$); -#8964=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_50','Mattresses',#8949,$,$); -#8965=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_77','Single beds',#8949,$,$); -#8966=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_96','Waterbeds',#8949,$,$); -#8967=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07','Bins and buckets',#8917,$,$); -#8968=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_02','Aggregate bins',#8967,$,$); -#8969=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_04','Ashtrays',#8967,$,$); -#8970=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_07','Bin stores',#8967,$,$); -#8971=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_10','Bulk storage fire sand bins',#8967,$,$); -#8972=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_12','Cemetery flower baskets',#8967,$,$); -#8973=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_19','Compost bins',#8967,$,$); -#8974=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_22','Disposal containers',#8967,$,$); -#8975=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_25','Dustbins',#8967,$,$); -#8976=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_33','Galvanized steel fire buckets',#8967,$,$); -#8977=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_35','Grit bins',#8967,$,$); -#8978=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_46','Linen containers',#8967,$,$); -#8979=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_47','Litter bins',#8967,$,$); -#8980=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_56','Nappy disposal bins',#8967,$,$); -#8981=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_57','Needle disposal boxes',#8967,$,$); -#8982=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_58','Non-segregated waste bins',#8967,$,$); -#8983=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_64','Plastics fire buckets',#8967,$,$); -#8984=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_70','Recycling bins',#8967,$,$); -#8985=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_71','Refuse bag holders',#8967,$,$); -#8986=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_72','Refuse bins',#8967,$,$); -#8987=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_75','Salt bins',#8967,$,$); -#8988=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_76','Sanitary towel disposal bins',#8967,$,$); -#8989=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_77','Segregated waste bins',#8967,$,$); -#8990=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_96','Waste bins',#8967,$,$); -#8991=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12','Chairs, seats and benches',#8917,$,$); -#8992=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_03','Armrests',#8991,$,$); -#8993=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_04','Assembly stacking chairs',#8991,$,$); -#8994=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_05','Auditorium chairs',#8991,$,$); -#8995=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_06','Barbell benches',#8991,$,$); -#8996=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_07','Benches',#8991,$,$); -#8997=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_12','Ceremonial chairs',#8991,$,$); -#8998=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_14','Chaises longue',#8991,$,$); -#8999=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_15','Changing benches',#8991,$,$); -#9000=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_16','Classroom seats',#8991,$,$); -#9001=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_20','Deck chairs',#8991,$,$); -#9002=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_21','Dining benches',#8991,$,$); -#9003=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_22','Dining chairs',#8991,$,$); -#9004=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_26','Easy chairs',#8991,$,$); -#9005=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_27','Electrically operated chairs',#8991,$,$); -#9006=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_30','Flip-up seats',#8991,$,$); -#9007=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_31','Folding chairs',#8991,$,$); -#9008=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_32','Footrests',#8991,$,$); -#9009=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_33','Garden benches',#8991,$,$); -#9010=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_37','High chairs',#8991,$,$); -#9011=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_46','Library chairs',#8991,$,$); -#9012=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_47','Linked seats',#8991,$,$); -#9013=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_48','Lounge chairs',#8991,$,$); -#9014=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_51','Meeting room chairs',#8991,$,$); -#9015=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_57','Office chairs',#8991,$,$); -#9016=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_59','Ottomans',#8991,$,$); -#9017=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_62','Pews',#8991,$,$); -#9018=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_63','Play chairs',#8991,$,$); -#9019=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_64','Portable observation poolside chairs',#8991,$,$); -#9020=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_71','Reception chairs',#8991,$,$); -#9021=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_72','Reclining chairs',#8991,$,$); -#9022=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_74','Rocking chairs',#8991,$,$); -#9023=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_76','Settees',#8991,$,$); -#9024=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_80','Sofa beds',#8991,$,$); -#9025=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_81','Sofas',#8991,$,$); -#9026=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_82','Stacking benches',#8991,$,$); -#9027=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_83','Stacking chairs',#8991,$,$); -#9028=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_84','Stacking pews',#8991,$,$); -#9029=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_85','Stools',#8991,$,$); -#9030=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_86','Study chairs',#8991,$,$); -#9031=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_87','Swing chairs',#8991,$,$); -#9032=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_88','Tennis umpire''s stands',#8991,$,$); -#9033=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_93','Upholstered benches',#8991,$,$); -#9034=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_94','Utility weight benches',#8991,$,$); -#9035=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_13','Clocks',#8917,$,$); -#9036=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_13_06','Battery analogue clocks',#9035,$,$); -#9037=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_13_22','Digital clocks',#9035,$,$); -#9038=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_13_26','Electric clocks',#9035,$,$); -#9039=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_13_29','Flip clocks',#9035,$,$); -#9040=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_13_51','Mechanical clocks',#9035,$,$); -#9041=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_13_61','Pendulum clocks',#9035,$,$); -#9042=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_13_66','Projection clocks',#9035,$,$); -#9043=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_13_70','Quartz clocks',#9035,$,$); -#9044=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_13_71','Radio clocks',#9035,$,$); -#9045=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_13_86','Sundials',#9035,$,$); -#9046=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_13_89','Torsion pendulum clocks',#9035,$,$); -#9047=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_13_96','Water clocks',#9035,$,$); -#9048=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21','Desks, tables and worktops',#8917,$,$); -#9049=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_05','Audio-visual tables',#9048,$,$); -#9050=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_08','Boardroom tables',#9048,$,$); -#9051=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_10','Bureaux',#9048,$,$); -#9052=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_11','Cable-managed podium tables',#9048,$,$); -#9053=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_13','Classroom desks and tables',#9048,$,$); -#9054=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_14','Coffee tables',#9048,$,$); -#9055=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_15','Conference tables',#9048,$,$); -#9056=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_16','Console tables',#9048,$,$); -#9057=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_17','Computer desks',#9048,$,$); -#9058=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_21','Desks',#9048,$,$); -#9059=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_22','Dining tables',#9048,$,$); -#9060=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_23','Display case tables',#9048,$,$); -#9061=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_24','Drafting machines',#9048,$,$); -#9062=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_25','Drawing boards',#9048,$,$); -#9063=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_26','Dressing tables',#9048,$,$); -#9064=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_29','Flip-top tables',#9048,$,$); -#9065=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_30','Folding dining room tables',#9048,$,$); -#9066=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_31','Folding tables',#9048,$,$); -#9067=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_32','Food preparation tables',#9048,$,$); -#9068=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_33','Gallery benches',#9048,$,$); -#9069=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_44','Kitchenettes',#9048,$,$); -#9070=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_45','Kitchen worktops',#9048,$,$); -#9071=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_46','Laboratory work benches and tables',#9048,$,$); -#9072=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_47','Laundry finishing tables',#9048,$,$); -#9073=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_48','Laundry spotting tables',#9048,$,$); -#9074=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_49','Light tables',#9048,$,$); -#9075=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_50','Manicure finishing tables',#9048,$,$); -#9076=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_51','Meeting room tables',#9048,$,$); -#9077=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_58','Occasional tables',#9048,$,$); -#9078=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_59','Office desks',#9048,$,$); -#9079=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_60','Office tables',#9048,$,$); -#9080=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_63','Play tables',#9048,$,$); -#9081=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_70','Reading desks',#9048,$,$); -#9082=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_73','Reference and search desks',#9048,$,$); -#9083=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_76','School art, design and technology tables',#9048,$,$); -#9084=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_84','Stand-up tables',#9048,$,$); -#9085=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_85','Study desks',#9048,$,$); -#9086=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_90','Touchdown desks',#9048,$,$); -#9087=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_96','Workstations',#9048,$,$); -#9088=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_98','Writing desks',#9048,$,$); -#9089=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_99','Writing tablets (detachable)',#9048,$,$); -#9090=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_28','Extinguishers and fire blankets',#8917,$,$); -#9091=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_28_11','Carbon dioxide fire extinguishers',#9090,$,$); -#9092=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_28_12','Carbon steel fire buckets',#9090,$,$); -#9093=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_28_24','Dry powder fire extinguishers',#9090,$,$); -#9094=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_28_28','Extinguisher floor stands',#9090,$,$); -#9095=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_28_29','Fire protective blankets',#9090,$,$); -#9096=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_28_30','Foam fire extinguishers',#9090,$,$); -#9097=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_28_31','Fire suppression liquid',#9090,$,$); -#9098=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_28_47','Heat protective blankets',#9090,$,$); -#9099=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_28_64','Portable fire extinguishers',#9090,$,$); -#9100=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_28_96','Water fire extinguishers',#9090,$,$); -#9101=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_28_97','Wet chemical fire extinguishers',#9090,$,$); -#9102=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_31','Furniture booths',#8917,$,$); -#9103=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_31_51','Meeting booths',#9102,$,$); -#9104=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_31_71','Restaurant booths',#9102,$,$); -#9105=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_33','Garden furnishings',#8917,$,$); -#9106=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_33_33','Garden awnings',#9105,$,$); -#9107=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_33_34','Garden umbrellas',#9105,$,$); -#9108=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51','Medical chairs and couches',#8917,$,$); -#9109=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_05','Bariatric patient chairs',#9108,$,$); -#9110=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_06','Bariatric plinth couches',#9108,$,$); -#9111=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_07','Blood sampling chairs',#9108,$,$); -#9112=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_08','Bo-plinth couches',#9108,$,$); -#9113=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_15','Commodes',#9108,$,$); -#9114=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_21','Day care couches',#9108,$,$); -#9115=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_22','Dental chairs',#9108,$,$); -#9116=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_23','Dialysis chairs',#9108,$,$); -#9117=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_25','Echocardiography couches',#9108,$,$); -#9118=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_26','Ear, nose and throat (ENT) and ophthalmic chairs',#9108,$,$); -#9119=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_27','Examination and treatment chairs',#9108,$,$); -#9120=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_28','Examination and treatment couches',#9108,$,$); -#9121=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_31','Foot stools',#9108,$,$); -#9122=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_34','Gynaecology chairs',#9108,$,$); -#9123=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_35','Gynaecology couches',#9108,$,$); -#9124=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_51','Minor operations couches',#9108,$,$); -#9125=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_58','Oncology chairs',#9108,$,$); -#9126=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_59','Outpatients couches',#9108,$,$); -#9127=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_61','Phlebotomy chairs',#9108,$,$); -#9128=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_62','Phlebotomy couches',#9108,$,$); -#9129=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_63','Plaster chairs',#9108,$,$); -#9130=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_65','Podiatry chairs',#9108,$,$); -#9131=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_71','Reclining treatment armchairs',#9108,$,$); -#9132=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_75','Sanitary seats',#9108,$,$); -#9133=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_84','Step stools',#9108,$,$); -#9134=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_92','Ultrasound couches',#9108,$,$); -#9135=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_52','Medical desks, tables and worktops',#8917,$,$); -#9136=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_52_22','Dissection tables',#9135,$,$); -#9137=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_52_50','Mayo tables',#9135,$,$); -#9138=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_52_57','Operating theatre tables',#9135,$,$); -#9139=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_52_58','Overbed tables',#9135,$,$); -#9140=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_52_59','Overchair tables',#9135,$,$); -#9141=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_52_65','Post-mortem tables',#9135,$,$); -#9142=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_52_88','Tilt tables',#9135,$,$); -#9143=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53','Medical trolleys',#8917,$,$); -#9144=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53_04','Armchair patient trolleys',#9143,$,$); -#9145=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53_06','Bariatric patient trolleys',#9143,$,$); -#9146=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53_24','Dressing trolleys',#9143,$,$); -#9147=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53_27','Emergency trolleys',#9143,$,$); -#9148=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53_33','General purpose medical trolleys',#9143,$,$); -#9149=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53_41','Instruments trolleys',#9143,$,$); -#9150=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53_48','Lockable hospital trolleys',#9143,$,$); -#9151=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53_51','Medical service carts',#9143,$,$); -#9152=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53_60','Patient notes trolleys',#9143,$,$); -#9153=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53_61','Patient trolleys',#9143,$,$); -#9154=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53_62','Phlebotomy trolleys',#9143,$,$); -#9155=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53_66','Procedure trolleys',#9143,$,$); -#9156=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53_81','Soiled linen trolleys',#9143,$,$); -#9157=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81','Soft furnishings',#8917,$,$); -#9158=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_06','Beanbags',#9157,$,$); -#9159=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_07','Blankets',#9157,$,$); -#9160=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_20','Cushions',#9157,$,$); -#9161=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_25','Duvets',#9157,$,$); -#9162=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_29','Flannels',#9157,$,$); -#9163=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_56','Napkins',#9157,$,$); -#9164=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_62','Pillows',#9157,$,$); -#9165=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_63','Placemats',#9157,$,$); -#9166=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_73','Rugs',#9157,$,$); -#9167=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_74','Runners',#9157,$,$); -#9168=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_77','Sheets',#9157,$,$); -#9169=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_86','Swags',#9157,$,$); -#9170=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_87','Tablecloths',#9157,$,$); -#9171=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_90','Towels',#9157,$,$); -#9172=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_91','Trimmings',#9157,$,$); -#9173=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_94','Valances',#9157,$,$); -#9174=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_83','Sports furnishings',#8917,$,$); -#9175=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_83_06','Balancing equipment',#9174,$,$); -#9176=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_83_19','Cricket wicket stump boxes',#9174,$,$); -#9177=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_83_20','Cycle ramps',#9174,$,$); -#9178=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_83_28','Equestrian riding equipment',#9174,$,$); -#9179=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_83_29','Fencing pistes',#9174,$,$); -#9180=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_83_44','Jumping equipment',#9174,$,$); -#9181=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_84','Stands',#8917,$,$); -#9182=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_84_09','Bowl stands',#9181,$,$); -#9183=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_84_23','Display banner stands',#9181,$,$); -#9184=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_84_28','Exhibit stands',#9181,$,$); -#9185=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_84_36','Hat stands',#9181,$,$); -#9186=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_84_42','Infusion stands',#9181,$,$); -#9187=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_84_51','Medical equipment stands',#9181,$,$); -#9188=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_84_66','Print stands',#9181,$,$); -#9189=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_84_92','Umbrella stands',#9181,$,$); -#9190=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_86','Swimming pool furnishings',#8917,$,$); -#9191=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_86_46','Lane rope storage bags',#9190,$,$); -#9192=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_86_62','Portable domestic diving boards',#9190,$,$); -#9193=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_86_64','Portable starting platforms',#9190,$,$); -#9194=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_86_66','Private use pool covers',#9190,$,$); -#9195=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_86_68','Public use pool covers',#9190,$,$); -#9196=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90','Trolleys',#8917,$,$); -#9197=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_08','Book trolleys',#9196,$,$); -#9198=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_15','Computer trolleys',#9196,$,$); -#9199=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_30','Fire trolleys',#9196,$,$); -#9200=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_31','Food preparation trolleys',#9196,$,$); -#9201=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_32','Food service trolleys',#9196,$,$); -#9202=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_33','Furniture trolleys',#9196,$,$); -#9203=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_46','Laundry trolleys',#9196,$,$); -#9204=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_47','Laundry bag trolleys',#9196,$,$); -#9205=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_49','Luggage trolleys',#9196,$,$); -#9206=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_52','Mailroom trolleys',#9196,$,$); -#9207=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_64','Pool lane rope storage trolleys',#9196,$,$); -#9208=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_72','Relay break detector storage trolleys',#9196,$,$); -#9209=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_76','Shopping trolleys',#9196,$,$); -#9210=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_82','Spa treatment trolleys',#9196,$,$); -#9211=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_87','Table storage trolleys',#9196,$,$); -#9212=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_88','Touchpad storage trolleys',#9196,$,$); -#9213=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_96','Wheels',#8917,$,$); -#9214=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_96_11','Castors',#9213,$,$); -#9215=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70','Equipment',#8344,$,$); -#9216=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_05','Audio visual equipment',#9215,$,$); -#9217=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_05_70','Radios',#9216,$,$); -#9218=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_05_88','Televisions',#9216,$,$); -#9219=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_13','Cleaning equipment',#9215,$,$); -#9220=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_13_50','Machine parts cleaning washer units',#9219,$,$); -#9221=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_13_58','Oil spillage cleaning units',#9219,$,$); -#9222=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_13_60','Orbital tank cleaners',#9219,$,$); -#9223=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_13_72','Robotic cleaning units',#9219,$,$); -#9224=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_15','Cold water supply sources',#9215,$,$); -#9225=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_15_24','Drinking fountains',#9224,$,$); -#9226=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_15_96','Water coolers',#9224,$,$); -#9227=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_21','Dishwashers',#9215,$,$); -#9228=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_21_16','Conveyor dishwashers',#9227,$,$); -#9229=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_21_22','Dish and utensil washers',#9227,$,$); -#9230=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_21_24','Domestic dishwashers',#9227,$,$); -#9231=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_21_30','Flight dishwashers',#9227,$,$); -#9232=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_21_60','Pass-through dishwashers',#9227,$,$); -#9233=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_21_92','Under-counter dishwashers',#9227,$,$); -#9234=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22','Dispensers and acceptance units',#9215,$,$); -#9235=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_05','Automated teller machines',#9234,$,$); -#9236=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_06','Barrier parking control units',#9234,$,$); -#9237=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_11','Cash dispensers',#9234,$,$); -#9238=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_15','Cold drink dispensers',#9234,$,$); -#9239=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_16','Collection boxes',#9234,$,$); -#9240=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_17','Condom dispensers',#9234,$,$); -#9241=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_22','Disposable apron dispensers',#9234,$,$); -#9242=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_23','Disposable glove dispensers',#9234,$,$); -#9243=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_24','Donation boxes',#9234,$,$); -#9244=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_25','Drive-by cash payment units',#9234,$,$); -#9245=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_29','Facial tissue dispensers',#9234,$,$); -#9246=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_31','Food waste disposal units',#9234,$,$); -#9247=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_36','Hand cleaning gel dispensers',#9234,$,$); -#9248=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_37','Hot drink dispensers',#9234,$,$); -#9249=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_38','Hot food dispensers',#9234,$,$); -#9250=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_47','Leaflet dispensers',#9234,$,$); -#9251=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_52','Multi-function dispensers',#9234,$,$); -#9252=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_56','Newspaper dispensers',#9234,$,$); -#9253=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_60','Packaged goods dispensers',#9234,$,$); -#9254=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_61','Paper roll dispensers',#9234,$,$); -#9255=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_62','Paper towel dispensers',#9234,$,$); -#9256=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_63','Parking meters',#9234,$,$); -#9257=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_64','Pay and display units',#9234,$,$); -#9258=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_66','Plate dispensers',#9234,$,$); -#9259=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_71','Refreshment dispensers',#9234,$,$); -#9260=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_75','Sanitary towel dispensers',#9234,$,$); -#9261=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_77','Shaving product dispensers',#9234,$,$); -#9262=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_80','Snack dispensers',#9234,$,$); -#9263=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_81','Soap dispensers',#9234,$,$); -#9264=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_85','Surface wipes dispensers',#9234,$,$); -#9265=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_86','Sweets dispensers',#9234,$,$); -#9266=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_88','Ticket dispensers',#9234,$,$); -#9267=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_90','Toilet paper dispensers',#9234,$,$); -#9268=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_92','Tool dispensers',#9234,$,$); -#9269=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23','Display and service catering products',#9215,$,$); -#9270=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23_06','Bains-marie',#9269,$,$); -#9271=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23_24','Drinks chillers',#9269,$,$); -#9272=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23_27','Espresso machines',#9269,$,$); -#9273=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23_31','Food display units',#9269,$,$); -#9274=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23_33','Food sneeze guards',#9269,$,$); -#9275=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23_40','Icemakers',#9269,$,$); -#9276=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23_42','Instant boiling and cold water taps',#9269,$,$); -#9277=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23_53','Mobile bains-marie',#9269,$,$); -#9278=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23_54','Mobile plain top hot cupboards',#9269,$,$); -#9279=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23_71','Refrigerated display cabinets',#9269,$,$); -#9280=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23_72','Refrigerated display counters',#9269,$,$); -#9281=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23_84','Static plain top hot cupboards',#9269,$,$); -#9282=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23_86','Sushi trains',#9269,$,$); -#9283=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24','Domestic cooking equipment',#9215,$,$); -#9284=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24_07','Built-in electric hobs',#9283,$,$); -#9285=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24_08','Built-in electric ovens',#9283,$,$); -#9286=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24_09','Built-in gas hobs',#9283,$,$); -#9287=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24_10','Built-in gas ovens',#9283,$,$); -#9288=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24_11','Built-in microwave ovens',#9283,$,$); -#9289=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24_15','Combination microwave ovens',#9283,$,$); -#9290=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24_26','Electric barbecues',#9283,$,$); -#9291=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24_27','Electric ranges',#9283,$,$); -#9292=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24_33','Gas barbecues',#9283,$,$); -#9293=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24_34','Gas ranges',#9283,$,$); -#9294=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24_35','Gas free-standing cookers',#9283,$,$); -#9295=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24_45','Kettles',#9283,$,$); -#9296=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24_81','Solid fuel barbecues',#9283,$,$); -#9297=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_25','Domestic laundry equipment',#9215,$,$); -#9298=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_25_45','Laundry tumble dryers',#9297,$,$); -#9299=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_25_46','Laundry washer-dryers',#9297,$,$); -#9300=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_25_47','Laundry washing machines',#9297,$,$); -#9301=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_27','Environmental protection equipment',#9215,$,$); -#9302=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_27_56','Oil containment booms',#9301,$,$); -#9303=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_29','Fire simulation equipment',#9215,$,$); -#9304=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_29_01','Aircraft fire training simulators',#9303,$,$); -#9305=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_31','Food refrigerators and freezers',#9215,$,$); -#9306=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_31_06','Blast chiller cabinets',#9305,$,$); -#9307=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_31_08','Blast freezer cabinets',#9305,$,$); -#9308=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_31_29','Freezer cabinets',#9305,$,$); -#9309=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_31_30','Freezer counters',#9305,$,$); -#9310=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_31_31','Freezers',#9305,$,$); -#9311=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_31_32','Fridge-freezers',#9305,$,$); -#9312=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_31_70','Refrigerated cabinets',#9305,$,$); -#9313=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_31_71','Refrigerated counters',#9305,$,$); -#9314=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_31_72','Refrigerators',#9305,$,$); -#9315=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_35','General workshop equipment',#9215,$,$); -#9316=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_35_15','Clipping machines',#9315,$,$); -#9317=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_35_35','Guillotines',#9315,$,$); -#9318=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_35_50','Magnetic tool holders',#9315,$,$); -#9319=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_35_60','Packaging machines',#9315,$,$); -#9320=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_35_67','Punch machines',#9315,$,$); -#9321=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_35_77','Shaping machines',#9315,$,$); -#9322=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_35_80','Slotting machines',#9315,$,$); -#9323=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_35_84','Strapping machines',#9315,$,$); -#9324=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_35_88','Threading machines',#9315,$,$); -#9325=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46','Laundry fittings and equipment',#9215,$,$); -#9326=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_24','Dryer ironers',#9325,$,$); -#9327=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_25','Dry work presses',#9325,$,$); -#9328=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_30','Flatwork ironers',#9325,$,$); -#9329=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_31','Form finishers',#9325,$,$); -#9330=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_39','Hydro extractors',#9325,$,$); -#9331=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_42','Ironing tables',#9325,$,$); -#9332=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_45','Laundry cabinets',#9325,$,$); -#9333=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_46','Laundry feeders',#9325,$,$); -#9334=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_47','Laundry folders',#9325,$,$); -#9335=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_48','Laundry recovery tanks',#9325,$,$); -#9336=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_72','Roller ironers',#9325,$,$); -#9337=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_77','Shirt finishers',#9325,$,$); -#9338=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_82','Spotting cabinets',#9325,$,$); -#9339=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_83','Spotting tables',#9325,$,$); -#9340=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_90','Trouser presses',#9325,$,$); -#9341=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_96','Washer extractors',#9325,$,$); -#9342=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_98','Water extraction presses',#9325,$,$); -#9343=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_99','Wet work presses',#9325,$,$); -#9344=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_47','Laundry washers and dryers',#9215,$,$); -#9345=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_47_06','Barrier washers',#9344,$,$); -#9346=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_47_07','Batch laundry dryers',#9344,$,$); -#9347=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_47_08','Batch laundry washers',#9344,$,$); -#9348=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_47_32','Front-loading washers',#9344,$,$); -#9349=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_47_46','Laundry dryers',#9344,$,$); -#9350=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_47_75','Sanitary barrier washers',#9344,$,$); -#9351=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_47_91','Tumble dryers',#9344,$,$); -#9352=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_47_97','Washer dryers',#9344,$,$); -#9353=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_50','Mail equipment',#9215,$,$); -#9354=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_50_32','Franking machines',#9353,$,$); -#9355=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_50_65','Post handling equipment',#9353,$,$); -#9356=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51','Medical and laboratory equipment',#9215,$,$); -#9357=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_04','Autoclaves',#9356,$,$); -#9358=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_10','Calorimeters',#9356,$,$); -#9359=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_16','Contamination control equipment',#9356,$,$); -#9360=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_22','Defibrillator units',#9356,$,$); -#9361=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_30','Fermenters',#9356,$,$); -#9362=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_32','First aid kits',#9356,$,$); -#9363=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_42','Incubators',#9356,$,$); -#9364=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_44','Jacketed vessels',#9356,$,$); -#9365=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_51','Microscopes',#9356,$,$); -#9366=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_59','Operating theatre equipment',#9356,$,$); -#9367=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_60','Oscilloscopes',#9356,$,$); -#9368=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_70','Retrievers',#9356,$,$); -#9369=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_84','Sterilisation equipment',#9356,$,$); -#9370=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_94','Vacuum furnaces',#9356,$,$); -#9371=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_55','Mooring and docking equipment',#9215,$,$); -#9372=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_55_05','Arch fenders',#9371,$,$); -#9373=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_55_15','Capstan',#9371,$,$); -#9374=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_55_20','Cone fenders',#9371,$,$); -#9375=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_55_22','Cell fenders',#9371,$,$); -#9376=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_55_50','Magnetic mooring devices',#9371,$,$); -#9377=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_55_53','Mooring line tensioners',#9371,$,$); -#9378=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_55_61','Pneumatic fenders',#9371,$,$); -#9379=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_55_69','Quick release mooring hooks',#9371,$,$); -#9380=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_55_95','Vacuum mooring devices',#9371,$,$); -#9381=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_58','Office equipment',#9215,$,$); -#9382=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_58_23','Document shredders',#9381,$,$); -#9383=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_58_46','Label makers',#9381,$,$); -#9384=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_58_60','Paper laminators',#9381,$,$); -#9385=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_62','Personal dryers',#9215,$,$); -#9386=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_62_09','Body dryers',#9385,$,$); -#9387=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_62_29','Face dryers',#9385,$,$); -#9388=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_62_36','Hairdryers',#9385,$,$); -#9389=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_62_37','Hand dryers',#9385,$,$); -#9390=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_63','Photographic equipment',#9215,$,$); -#9391=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_63_04','Automated film developing equipment',#9390,$,$); -#9392=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_63_05','Automated printing equipment',#9390,$,$); -#9393=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_63_28','Enlargers',#9390,$,$); -#9394=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_63_35','Graphics cameras',#9390,$,$); -#9395=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65','Preparation catering equipment',#9215,$,$); -#9396=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_16','Conveyor toasters',#9395,$,$); -#9397=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_17','Drink making equipment',#9395,$,$); -#9398=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_18','Electric boiling pans',#9395,$,$); -#9399=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_19','Electric boiling tables',#9395,$,$); -#9400=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_20','Electric bratt pans',#9395,$,$); -#9401=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_21','Electric cooking ranges',#9395,$,$); -#9402=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_22','Electric deep fat fryers',#9395,$,$); -#9403=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_23','Electric fryers',#9395,$,$); -#9404=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_24','Electric griddles',#9395,$,$); -#9405=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_25','Electric grills',#9395,$,$); -#9406=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_26','Electric hot water dispensers',#9395,$,$); -#9407=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_27','Electric ovens',#9395,$,$); -#9408=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_28','Electric steaming ovens',#9395,$,$); -#9409=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_29','Food blenders',#9395,$,$); -#9410=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_30','Food mincers',#9395,$,$); -#9411=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_31','Food mixers',#9395,$,$); -#9412=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_32','Food smokers',#9395,$,$); -#9413=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_33','Gas boiling pans',#9395,$,$); -#9414=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_34','Gas boiling tables',#9395,$,$); -#9415=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_35','Gas bratt pans',#9395,$,$); -#9416=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_36','Gas cooking ranges',#9395,$,$); -#9417=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_37','Gas deep fat fryers',#9395,$,$); -#9418=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_38','Gas fryers',#9395,$,$); -#9419=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_39','Gas griddles',#9395,$,$); -#9420=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_40','Gas grills',#9395,$,$); -#9421=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_41','Gas ovens',#9395,$,$); -#9422=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_42','Gas steaming ovens',#9395,$,$); -#9423=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_43','General purpose electric ovens',#9395,$,$); -#9424=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_44','General purpose gas ovens',#9395,$,$); -#9425=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_45','Gravity feed slicers',#9395,$,$); -#9426=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_46','Hot cupboards',#9395,$,$); -#9427=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_51','Microwave ovens',#9395,$,$); -#9428=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_65','Potato peelers',#9395,$,$); -#9429=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_79','Slot toasters',#9395,$,$); -#9430=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_94','Vegetable preparation machines',#9395,$,$); -#9431=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_67','Projectors',#9215,$,$); -#9432=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_67_14','Cinematic projectors',#9431,$,$); -#9433=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_67_22','Digital projectors',#9431,$,$); -#9434=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_67_29','Film projectors',#9431,$,$); -#9435=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_67_63','Planetarium projectors',#9431,$,$); -#9436=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_67_79','Slide projectors',#9431,$,$); -#9437=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_71','Recreation equipment',#9215,$,$); -#9438=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_71_04','Arcade machines',#9437,$,$); -#9439=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_71_87','Tanning units',#9437,$,$); -#9440=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73','Rolling stock depot equipment',#9215,$,$); -#9441=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_06','Bogie drops',#9440,$,$); -#9442=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_07','Bogie presses',#9440,$,$); -#9443=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_08','Bogie racks',#9440,$,$); -#9444=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_09','Bogie turntables',#9440,$,$); -#9445=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_10','Bogie workstands',#9440,$,$); -#9446=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_23','Drophead buckeye couplers',#9440,$,$); -#9447=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_24','Drophead buckeye drawgears',#9440,$,$); -#9448=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_30','Fixed CETs',#9440,$,$); -#9449=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_47','Lifting tables',#9440,$,$); -#9450=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_70','Rail vehicle lifting jacks',#9440,$,$); -#9451=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_73','Retractable buffers',#9440,$,$); -#9452=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_75','Sand plant',#9440,$,$); -#9453=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_95','Wheel drops',#9440,$,$); -#9454=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_96','Wheel lathes',#9440,$,$); -#9455=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_97','Wheelset presses',#9440,$,$); -#9456=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_98','Wheel stops',#9440,$,$); -#9457=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75','Safety equipment',#9215,$,$); -#9458=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_01','Access cradles',#9457,$,$); -#9459=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_27','Electrically powered winches',#9457,$,$); -#9460=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_28','Evacuation chairs',#9457,$,$); -#9461=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_29','Fall arrester devices',#9457,$,$); -#9462=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_33','Gantries',#9457,$,$); -#9463=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_35','Guided type fall arresters',#9457,$,$); -#9464=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_36','Hand climbing devices',#9457,$,$); -#9465=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_37','Harnesses and lanyards',#9457,$,$); -#9466=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_39','Hoist equipment storage units',#9457,$,$); -#9467=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_50','Manual push',#9457,$,$); -#9468=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_51','Manual winches',#9457,$,$); -#9469=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_55','Mullion guides',#9457,$,$); -#9470=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_66','Protection netting',#9457,$,$); -#9471=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_72','Rope and pulley devices',#9457,$,$); -#9472=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_75','Safety access anchor devices',#9457,$,$); -#9473=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_76','Safety access equipment winding handles',#9457,$,$); -#9474=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_77','Safety harnesses',#9457,$,$); -#9475=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_79','Safety netting',#9457,$,$); -#9476=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_81','Spillage control kits',#9457,$,$); -#9477=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_82','Stair climbing trolleys',#9457,$,$); -#9478=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_83','Suspended access tracks',#9457,$,$); -#9479=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_84','Suspended chairs',#9457,$,$); -#9480=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_85','Suspension rigs',#9457,$,$); -#9481=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_86','Suspension rope restraints',#9457,$,$); -#9482=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_96','Working platforms',#9457,$,$); -#9483=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_97','Working platform storage units',#9457,$,$); -#9484=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84','Sports equipment',#9215,$,$); -#9485=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_01','Abdominal machines',#9484,$,$); -#9486=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_04','Arm machines',#9484,$,$); -#9487=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_06','Back machines',#9484,$,$); -#9488=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_11','Cable machines',#9484,$,$); -#9489=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_13','Chest and shoulder machines',#9484,$,$); -#9490=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_16','Cross trainers',#9484,$,$); -#9491=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_26','Elliptical trainers',#9484,$,$); -#9492=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_27','Exercise bikes',#9484,$,$); -#9493=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_46','Leg machines',#9484,$,$); -#9494=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_47','Leverage units',#9484,$,$); -#9495=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_55','Multi-gyms',#9484,$,$); -#9496=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_65','Pool, snooker and billiards tables',#9484,$,$); -#9497=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_66','Power cages and racks',#9484,$,$); -#9498=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_67','Power plates',#9484,$,$); -#9499=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_68','Punch bags',#9484,$,$); -#9500=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_72','Rowing machines',#9484,$,$); -#9501=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_80','Smith machines',#9484,$,$); -#9502=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_84','Steppers',#9484,$,$); -#9503=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_86','Suspension trainers',#9484,$,$); -#9504=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_90','Trampolines',#9484,$,$); -#9505=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_91','Treadmills',#9484,$,$); -#9506=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_92','Upper body trainers',#9484,$,$); -#9507=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_94','Vertical knee raise and dip machines',#9484,$,$); -#9508=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_85','Stage equipment',#9215,$,$); -#9509=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_85_31','Fly/ pulley bars',#9508,$,$); -#9510=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_86','Swimming pool equipment',#9215,$,$); -#9511=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_86_02','Air cushion equipment',#9510,$,$); -#9512=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_86_08','Buoyancy-aided movable floors',#9510,$,$); -#9513=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_86_10','Buoyancy-aided movable bulkheads',#9510,$,$); -#9514=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_86_52','Mechanical drive movable floors',#9510,$,$); -#9515=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_86_60','Pool structure-supported movable bulkheads',#9510,$,$); -#9516=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_86_84','Surface agitation equipment',#9510,$,$); -#9517=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_86_94','Water polo ball release devices',#9510,$,$); -#9518=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_86_98','Wave machine equipment',#9510,$,$); -#9519=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_96','Water control equipment',#9215,$,$); -#9520=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_96_30','Flow control device chambers',#9519,$,$); -#9521=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_96_31','Flow control devices',#9519,$,$); -#9522=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_99','Weighing equipment',#9215,$,$); -#9523=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_99_22','Digital scales',#9522,$,$); -#9524=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_99_42','Industrial scales',#9522,$,$); -#9525=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_99_45','Kitchen scales',#9522,$,$); -#9526=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_99_62','Personnel weighing scales',#9522,$,$); -#9527=IFCCLASSIFICATIONREFERENCE($,'Pr_45','Flora and fauna products',#4921,$,$); -#9528=IFCCLASSIFICATIONREFERENCE($,'Pr_45_28','Fauna products',#9527,$,$); -#9529=IFCCLASSIFICATIONREFERENCE($,'Pr_45_28_30','Fish, eel and lamprey pass products',#9528,$,$); -#9530=IFCCLASSIFICATIONREFERENCE($,'Pr_45_28_30_10','Bristle boards and mats',#9529,$,$); -#9531=IFCCLASSIFICATIONREFERENCE($,'Pr_45_28_30_27','Eel tiles',#9529,$,$); -#9532=IFCCLASSIFICATIONREFERENCE($,'Pr_45_28_30_46','Larinier tiles',#9529,$,$); -#9533=IFCCLASSIFICATIONREFERENCE($,'Pr_45_28_30_78','Siphon fish passes',#9529,$,$); -#9534=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30','Flora products',#9527,$,$); -#9535=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_04','Artificial plants',#9534,$,$); -#9536=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_04_02','Artificial grass',#9535,$,$); -#9537=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_04_03','Artificial low growing trees',#9535,$,$); -#9538=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_04_04','Artificial topiary and pleaching',#9535,$,$); -#9539=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_04_05','Artificial trees',#9535,$,$); -#9540=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_04_64','Polyester silk plants',#9535,$,$); -#9541=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_04_66','Preserved plants',#9535,$,$); -#9542=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_10','Bulbs, corms, tubers and dormant roots',#9534,$,$); -#9543=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_10_04','Annual tubers',#9542,$,$); -#9544=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_10_10','Bulbs',#9542,$,$); -#9545=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_10_15','Corms',#9542,$,$); -#9546=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_10_62','Perennial roots',#9542,$,$); -#9547=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_10_63','Perennial tubers',#9542,$,$); -#9548=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_36','Herbaceous and aquatic plants',#9534,$,$); -#9549=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_36_02','Annual plugs',#9548,$,$); -#9550=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_36_03','Aquatic plant bare roots and clumps',#9548,$,$); -#9551=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_36_04','Aquatic plant bunches',#9548,$,$); -#9552=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_36_05','Aquatic plant pots and baskets',#9548,$,$); -#9553=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_36_06','Aquatic plant plugs',#9548,$,$); -#9554=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_36_11','Cell-grown annuals',#9548,$,$); -#9555=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_36_13','Cell-grown perennials',#9548,$,$); -#9556=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_36_14','Container-grown aquatic plants',#9548,$,$); -#9557=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_36_15','Container-grown annuals',#9548,$,$); -#9558=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_36_16','Container-grown perennials',#9548,$,$); -#9559=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_36_64','Perennial clumps',#9548,$,$); -#9560=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_36_65','Perennial plugs',#9548,$,$); -#9561=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_76','Seeds',#9534,$,$); -#9562=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_76_29','Flower seeds',#9561,$,$); -#9563=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_76_32','Fruit seeds',#9561,$,$); -#9564=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_76_34','Grass seeds',#9561,$,$); -#9565=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_76_39','Hydroseeding mixes',#9561,$,$); -#9566=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_76_48','Locally collected seeds',#9561,$,$); -#9567=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_76_77','Site-grown temporary crop seeds',#9561,$,$); -#9568=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_76_90','Tree and shrub seeds',#9561,$,$); -#9569=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_76_94','Vegetable seeds',#9561,$,$); -#9570=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_76_97','Wildflower seeds',#9561,$,$); -#9571=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80','Shrubs and woody climbers',#9534,$,$); -#9572=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80_04','Bare-root climbers',#9571,$,$); -#9573=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80_06','Bare-root cutting-raised roses',#9571,$,$); -#9574=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80_08','Bare-root shrubs',#9571,$,$); -#9575=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80_10','Bare-root budded roses',#9571,$,$); -#9576=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80_11','Cell-grown climbers',#9571,$,$); -#9577=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80_12','Cell-grown shrubs',#9571,$,$); -#9578=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80_14','Container-grown bamboos',#9571,$,$); -#9579=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80_15','Container-grown budded roses',#9571,$,$); -#9580=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80_16','Container-grown climbers',#9571,$,$); -#9581=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80_18','Container-grown cutting-raised roses',#9571,$,$); -#9582=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80_20','Container-grown shrubs',#9571,$,$); -#9583=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80_71','Rootballed bamboos',#9571,$,$); -#9584=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80_73','Rootballed shrubs',#9571,$,$); -#9585=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_90','Trees',#9534,$,$); -#9586=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_90_05','Bare-root conifers',#9585,$,$); -#9587=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_90_07','Bare-root fruit trees',#9585,$,$); -#9588=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_90_09','Bare-root trees',#9585,$,$); -#9589=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_90_11','Cell-grown conifers',#9585,$,$); -#9590=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_90_13','Cell-grown trees',#9585,$,$); -#9591=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_90_17','Container-grown conifers',#9585,$,$); -#9592=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_90_19','Container-grown fruit trees',#9585,$,$); -#9593=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_90_21','Container-grown trees',#9585,$,$); -#9594=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_90_72','Rootballed conifers',#9585,$,$); -#9595=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_90_74','Rootballed trees',#9585,$,$); -#9596=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31','Formless flora and fauna products',#9527,$,$); -#9597=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_03','Animal biocides',#9596,$,$); -#9598=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_03_08','Biological controls',#9597,$,$); -#9599=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_03_42','Insecticides',#9597,$,$); -#9600=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_03_64','Poisons',#9597,$,$); -#9601=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_03_72','Rodenticides',#9597,$,$); -#9602=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_03_88','Termite-resistant granules',#9597,$,$); -#9603=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_03_90','Termiticides',#9597,$,$); -#9604=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_03_96','Worm controls',#9597,$,$); -#9605=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_37','Herbicides',#9596,$,$); -#9606=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_37_15','Combined selective lawn herbicide and feed mixes',#9605,$,$); -#9607=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_37_56','Non-selective contact herbicides',#9605,$,$); -#9608=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_37_57','Non-selective residual herbicides',#9605,$,$); -#9609=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_37_58','Non-selective systemic herbicides',#9605,$,$); -#9610=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_37_76','Selective herbicides',#9605,$,$); -#9611=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_52','Microbial biocides',#9596,$,$); -#9612=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_52_03','Algaecides',#9611,$,$); -#9613=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_52_07','Biocides',#9611,$,$); -#9614=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_52_31','Fungicidal solutions',#9611,$,$); -#9615=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_52_32','Fungicides',#9611,$,$); -#9616=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_52_55','Non-oxidizing water treatment biocides',#9611,$,$); -#9617=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_52_59','Oxidizing water treatment biocides',#9611,$,$); -#9618=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_52_62','Plant fungicides',#9611,$,$); -#9619=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_52_73','Root sealers',#9611,$,$); -#9620=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_52_86','Surface biocides',#9611,$,$); -#9621=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_52_97','Vermicides',#9611,$,$); -#9622=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63','Plant-based fibres',#9596,$,$); -#9623=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_14','Coir fibres',#9622,$,$); -#9624=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_15','Combed wheat reed',#9622,$,$); -#9625=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_16','Compostable plant material',#9622,$,$); -#9626=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_30','Flax fibres',#9622,$,$); -#9627=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_37','Hemp fibres',#9622,$,$); -#9628=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_44','Jute fibres',#9622,$,$); -#9629=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_47','Long straw',#9622,$,$); -#9630=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_48','Loose straw',#9622,$,$); -#9631=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_56','Natural bark',#9622,$,$); -#9632=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_60','Paper bales',#9622,$,$); -#9633=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_64','Playground bark',#9622,$,$); -#9634=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_76','Sedge',#9622,$,$); -#9635=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_78','Sisal fibres',#9622,$,$); -#9636=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_80','Sphagnum moss',#9622,$,$); -#9637=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_84','Straw bales',#9622,$,$); -#9638=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_96','Water reed',#9622,$,$); -#9639=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_97','Wood chips',#9622,$,$); -#9640=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_98','Wood fibres',#9622,$,$); -#9641=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89','Topsoils, feeds and growing mediums',#9596,$,$); -#9642=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_08','Blood and bonemeal',#9641,$,$); -#9643=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_15','Compost dressings',#9641,$,$); -#9644=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_16','Composted materials',#9641,$,$); -#9645=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_35','Green roof substrates',#9641,$,$); -#9646=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_41','Imported growing mediums',#9641,$,$); -#9647=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_42','Imported topsoils',#9641,$,$); -#9648=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_43','Inorganic fertilizers',#9641,$,$); -#9649=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_50','Manufactured growing mediums',#9641,$,$); -#9650=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_51','Manufactured topsoils',#9641,$,$); -#9651=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_52','Manures',#9641,$,$); -#9652=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_55','Mycorrhizal inoculants',#9641,$,$); -#9653=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_57','Non-compost turf dressings',#9641,$,$); -#9654=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_58','Organic fertilizers',#9641,$,$); -#9655=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_75','Sanitized and stabilized composts',#9641,$,$); -#9656=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_80','Soil amelioration aggregates',#9641,$,$); -#9657=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_81','Soil amelioration industrial by-products',#9641,$,$); -#9658=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_82','Soil amelioration minerals',#9641,$,$); -#9659=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_83','Soil conditioning agents',#9641,$,$); -#9660=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_84','Soil moisture retention additives',#9641,$,$); -#9661=IFCCLASSIFICATIONREFERENCE($,'Pr_45_57','Non-rigid sheet, mat and strip flora and fauna products',#9527,$,$); -#9662=IFCCLASSIFICATIONREFERENCE($,'Pr_45_57_91','Turf and pre-planted substrates',#9661,$,$); -#9663=IFCCLASSIFICATIONREFERENCE($,'Pr_45_57_91_20','Cultivated turf',#9662,$,$); -#9664=IFCCLASSIFICATIONREFERENCE($,'Pr_45_57_91_56','Natural turf',#9662,$,$); -#9665=IFCCLASSIFICATIONREFERENCE($,'Pr_45_57_91_63','Pre-planted coir rolls',#9662,$,$); -#9666=IFCCLASSIFICATIONREFERENCE($,'Pr_45_57_91_64','Pre-planted pallets',#9662,$,$); -#9667=IFCCLASSIFICATIONREFERENCE($,'Pr_45_57_91_65','Pre-planted vegetation mats',#9662,$,$); -#9668=IFCCLASSIFICATIONREFERENCE($,'Pr_45_57_91_67','Pre-seeded mats',#9662,$,$); -#9669=IFCCLASSIFICATIONREFERENCE($,'Pr_45_57_91_76','Seeded area turf edging',#9662,$,$); -#9670=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63','Plant support products',#9527,$,$); -#9671=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63','Plant containers',#9670,$,$); -#9672=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_02','Aluminium divided modular units',#9671,$,$); -#9673=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_03','Aluminium edge retaining profiles',#9671,$,$); -#9674=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_04','Aluminium plant containers',#9671,$,$); -#9675=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_05','Aquatic plant containers',#9671,$,$); -#9676=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_07','Biodegradable plant containers',#9671,$,$); -#9677=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_11','Cast and wrought iron plant containers',#9671,$,$); -#9678=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_15','Concrete and reconstituted aggregate plant containers',#9671,$,$); -#9679=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_17','Cropping bags',#9671,$,$); -#9680=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_22','Divided modular planting units',#9671,$,$); -#9681=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_29','Flower pouches',#9671,$,$); -#9682=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_34','Glass-reinforced plastic (GRP) and advanced composite (AC) plant containers',#9671,$,$); -#9683=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_36','Hanging plant containers',#9671,$,$); -#9684=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_37','Herb planters',#9671,$,$); -#9685=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_38','Herb wheels',#9671,$,$); -#9686=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_56','Natural planting cassettes',#9671,$,$); -#9687=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_62','Plastics divided modular units',#9671,$,$); -#9688=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_64','Polymer plant containers',#9671,$,$); -#9689=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_65','Potato planters',#9671,$,$); -#9690=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_72','Round plant containers',#9671,$,$); -#9691=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_80','Square plant containers',#9671,$,$); -#9692=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_81','Stainless steel divided modular units',#9671,$,$); -#9693=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_82','Stainless steel edge retaining profiles',#9671,$,$); -#9694=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_83','Stainless steel plant containers',#9671,$,$); -#9695=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_84','Steel plant containers',#9671,$,$); -#9696=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_85','Stone plant containers',#9671,$,$); -#9697=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_86','Strawberry planters',#9671,$,$); -#9698=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_87','Terracotta plant containers',#9671,$,$); -#9699=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_88','Terrariums',#9671,$,$); -#9700=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_89','Treated timber plant containers',#9671,$,$); -#9701=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_90','Trough plant containers',#9671,$,$); -#9702=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_92','Untreated timber plant containers',#9671,$,$); -#9703=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_94','Vases',#9671,$,$); -#9704=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_96','Wall planters',#9671,$,$); -#9705=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_97','Window boxes',#9671,$,$); -#9706=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64','Plant support and protection',#9670,$,$); -#9707=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_11','Canes',#9706,$,$); -#9708=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_14','Climbing plant supports',#9706,$,$); -#9709=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_15','Concrete tree surrounds',#9706,$,$); -#9710=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_30','Floral foam fixing mediums',#9706,$,$); -#9711=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_33','Geocellular modular plastics structured soil units',#9706,$,$); -#9712=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_35','Guy wire kits',#9706,$,$); -#9713=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_63','Plastics mesh reinforcement',#9706,$,$); -#9714=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_66','Polystyrene (PS) fixing mediums',#9706,$,$); -#9715=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_67','Protective fencing',#9706,$,$); -#9716=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_72','Rootball securing frames',#9706,$,$); -#9717=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_78','Shrub protectors',#9706,$,$); -#9718=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_80','Softwood pegs',#9706,$,$); -#9719=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_83','Stake ties',#9706,$,$); -#9720=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_84','Stakes',#9706,$,$); -#9721=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_86','Tensioned wire trellises',#9706,$,$); -#9722=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_87','Tree grilles',#9706,$,$); -#9723=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_88','Tree guards',#9706,$,$); -#9724=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_89','Tree protectors',#9706,$,$); -#9725=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_90','Trellises',#9706,$,$); -#9726=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_96','Weed control mats',#9706,$,$); -#9727=IFCCLASSIFICATIONREFERENCE($,'Pr_50','Fabric accessory products',#4921,$,$); -#9728=IFCCLASSIFICATIONREFERENCE($,'Pr_60','Services source products',#4921,$,$); -#9729=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45','Water filtration and treatment products',#9728,$,$); -#9730=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_01','Aerator products',#9729,$,$); -#9731=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_01_11','Cascade trays',#9730,$,$); -#9732=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_01_30','Fine bubble diffuser manifolds',#9730,$,$); -#9733=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_01_37','High speed vertical shaft surface aerators',#9730,$,$); -#9734=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_01_38','Horizontal shaft surface aerators',#9730,$,$); -#9735=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_01_44','Jet aeration manifolds',#9730,$,$); -#9736=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_01_48','Low speed vertical shaft surface aerators',#9730,$,$); -#9737=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_01_96','Wind powered aerators',#9730,$,$); -#9738=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_03','Air blower products',#9729,$,$); -#9739=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_03_12','Centrifugal blowers',#9738,$,$); -#9740=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_03_55','Multicore blowers',#9738,$,$); -#9741=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_03_72','Rotary lobe air blowers',#9738,$,$); -#9742=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_03_73','Rotary screw blowers',#9738,$,$); -#9743=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_03_78','Side channel blowers',#9738,$,$); -#9744=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_03_90','Turbo blowers',#9738,$,$); -#9745=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_07','Biological filtration wastewater treatment products',#9729,$,$); -#9746=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_07_21','De Hoxar separators',#9745,$,$); -#9747=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_07_22','Dissolved air flotation plants',#9745,$,$); -#9748=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_07_23','Disc biological filters',#9745,$,$); -#9749=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_07_25','Drum filters',#9745,$,$); -#9750=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_07_46','Lamella plate packs',#9745,$,$); -#9751=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_07_51','Membrane bio-reactors',#9745,$,$); -#9752=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_07_60','Packaged lamella units',#9745,$,$); -#9753=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_07_72','Rotating biological contactors',#9745,$,$); -#9754=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_12','Centrifuge products',#9729,$,$); -#9755=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_22','Decanters',#9729,$,$); -#9756=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_22_30','Floating decanters',#9755,$,$); -#9757=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_22_52','Motor driven moving arm decanters',#9755,$,$); -#9758=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_24','Distributor products',#9729,$,$); -#9759=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_24_52','Motorized trickling filter distributor arms',#9758,$,$); -#9760=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_24_60','Paddlewheel trickling filter distributor arms',#9758,$,$); -#9761=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_24_72','Rotary reaction trickling filter distributor arms and syphons',#9758,$,$); -#9762=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_24_90','Turbine trickling filter distributor arms',#9758,$,$); -#9763=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_29','Filtration mediums',#9729,$,$); -#9764=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_29_14','Clay trickling filter floor tiles',#9763,$,$); -#9765=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_29_16','Concrete trickling filter floor tiles',#9763,$,$); -#9766=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_29_65','Plastics structured cross-flow mediums',#9763,$,$); -#9767=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_29_70','Random packed plastics mediums',#9763,$,$); -#9768=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_30','Flow control products',#9729,$,$); -#9769=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_30_15','Composite plastics penstocks',#9768,$,$); -#9770=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_30_23','Diffuser drums',#9768,$,$); -#9771=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_30_31','Float activated flow control units',#9768,$,$); -#9772=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_30_52','Metal penstocks',#9768,$,$); -#9773=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_30_83','Stop gates',#9768,$,$); -#9774=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_30_84','Stop logs',#9768,$,$); -#9775=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_30_93','Vortex water flow controls',#9768,$,$); -#9776=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_30_95','Water baffles',#9768,$,$); -#9777=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_30_96','Weir gates',#9768,$,$); -#9778=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_30_97','Weir plates',#9768,$,$); -#9779=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_33','Grit trap products',#9729,$,$); -#9780=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_33_17','Cross-flow separators',#9779,$,$); -#9781=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_33_57','Non-powered vortex separators',#9779,$,$); -#9782=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_33_65','Powered vortex flow separators',#9779,$,$); -#9783=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_34','Grit classifier products',#9729,$,$); -#9784=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_34_15','Classifier vortex washer and de-waterers',#9783,$,$); -#9785=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_34_71','Reciprocating rake classifiers',#9783,$,$); -#9786=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_34_76','Screw classifiers',#9783,$,$); -#9787=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_46','Launder trough products',#9729,$,$); -#9788=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_46_46','Launder troughs',#9787,$,$); -#9789=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_58','Odour control tank cover products',#9729,$,$); -#9790=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_58_33','Gas containment covers',#9789,$,$); -#9791=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_58_58','Odour control covers',#9789,$,$); -#9792=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_74','Scum removal products',#9729,$,$); -#9793=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_74_30','Fixed scum pipes',#9792,$,$); -#9794=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_74_72','Rotating scum pipes',#9792,$,$); -#9795=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_74_75','Scum beaches',#9792,$,$); -#9796=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_74_76','Scum removal boards',#9792,$,$); -#9797=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_74_77','Scum removal valves',#9792,$,$); -#9798=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_74_85','Surface scum scrapers',#9792,$,$); -#9799=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_76','Sludge de-watering products',#9729,$,$); -#9800=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_76_07','Belt presses',#9799,$,$); -#9801=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_76_22','Decanter centrifuges',#9799,$,$); -#9802=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_76_65','Plate presses',#9799,$,$); -#9803=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_78','Sludge removal products',#9729,$,$); -#9804=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_78_08','Bottom sludge scrapers',#9803,$,$); -#9805=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_78_12','Chain and flight scrapers',#9803,$,$); -#9806=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_78_72','Rotating full bridge scrapers',#9803,$,$); -#9807=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_78_73','Rotating half bridge scrapers',#9803,$,$); -#9808=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_78_78','Siphons',#9803,$,$); -#9809=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_79','Sludge screening products',#9729,$,$); -#9810=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_79_34','Gravity sludge screens',#9809,$,$); -#9811=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_79_65','Pressurized sludge screens',#9809,$,$); -#9812=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_80','Sludge thickening products',#9729,$,$); -#9813=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_80_24','Drum thickeners',#9812,$,$); -#9814=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_80_34','Gravity belt thickeners',#9812,$,$); -#9815=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_80_63','Picket fence thickeners',#9812,$,$); -#9816=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_85','Suspended growth and tertiary wastewater treatment products',#9729,$,$); -#9817=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_90','Wastewater and water mixer products',#9729,$,$); -#9818=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_90_15','Channel mixers',#9817,$,$); -#9819=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_90_51','Mechanical mixers',#9817,$,$); -#9820=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_90_85','Static pipe mixers',#9817,$,$); -#9821=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_90_86','Submersible propeller mixers',#9817,$,$); -#9822=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_93','Wastewater screenings treatment products',#9729,$,$); -#9823=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_93_42','Impeller and compactor tank wash',#9822,$,$); -#9824=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_93_50','Macerator and de-waterer tank wash',#9822,$,$); -#9825=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_93_75','Screw compactors',#9822,$,$); -#9826=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_93_96','Washer compactors',#9822,$,$); -#9827=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94','Wastewater screening and water abstraction products',#9729,$,$); -#9828=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_06','Band screens',#9827,$,$); -#9829=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_08','Brushed and macerator combined screens',#9827,$,$); -#9830=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_09','Brushed screens',#9827,$,$); -#9831=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_15','Coanda screens',#9827,$,$); -#9832=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_23','Disc screens',#9827,$,$); -#9833=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_25','Drum screens',#9827,$,$); -#9834=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_29','Finescreens',#9827,$,$); -#9835=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_30','Flushing screens',#9827,$,$); -#9836=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_34','Grab screens',#9827,$,$); -#9837=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_70','Raked bar screens',#9827,$,$); -#9838=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_72','Rotary drum screens',#9827,$,$); -#9839=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_73','Rotating bar interceptors',#9827,$,$); -#9840=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_78','Slot screens',#9827,$,$); -#9841=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_80','Spiral and compaction combined screens',#9827,$,$); -#9842=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_81','Spiral screens',#9827,$,$); -#9843=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_83','Static perforated plate screens',#9827,$,$); -#9844=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_84','Static wedge wire screens',#9827,$,$); -#9845=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_85','Step screens',#9827,$,$); -#9846=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_95','Wastewater settlement products',#9729,$,$); -#9847=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_95_15','Conical glass reinforced plastics (GRP) settlement tanks',#9846,$,$); -#9848=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_96','Wastewater tank flushing products',#9729,$,$); -#9849=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_96_14','Circular tank flushing vessels',#9848,$,$); -#9850=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_96_30','Flushing gates',#9848,$,$); -#9851=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_96_89','Tipping troughs',#9848,$,$); -#9852=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_96_94','Vacuum operated storage reservoirs',#9848,$,$); -#9853=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50','Tank, cylinder and vessel products',#9728,$,$); -#9854=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_10','Bulk storage tanks',#9853,$,$); -#9855=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_10_34','Glass fused steel tanks',#9854,$,$); -#9856=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_10_64','Plastics tanks',#9854,$,$); -#9857=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_10_66','Precast concrete modular tanks',#9854,$,$); -#9858=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_20','Cylinders and buffer vessels',#9853,$,$); -#9859=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_20_02','Accumulators',#9858,$,$); -#9860=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_20_10','Buffer vessels',#9858,$,$); -#9861=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_20_21','Direct hot water storage cylinders',#9858,$,$); -#9862=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_20_22','Direct insulated hot water combination units',#9858,$,$); -#9863=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_20_23','Double feed indirect hot water storage cylinders',#9858,$,$); -#9864=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_20_24','Double feed indirect insulated hot water combination units',#9858,$,$); -#9865=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_20_25','Dual coil hot water storage cylinders',#9858,$,$); -#9866=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_20_28','Expansion vessels',#9858,$,$); -#9867=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_20_42','Indirectly heated unvented hot water storage cylinders',#9858,$,$); -#9868=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_20_77','Single feed indirect insulated combination units',#9858,$,$); -#9869=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_20_78','Single feed indirect hot water storage cylinders',#9858,$,$); -#9870=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_33','Gas storage cylinders',#9853,$,$); -#9871=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_33_14','Compressed air cylinders',#9870,$,$); -#9872=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_33_15','Compressed gas cylinders',#9870,$,$); -#9873=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_33_37','High pressure fire extinguishing gas storage cylinders',#9870,$,$); -#9874=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_33_46','Liquefied gas cylinders',#9870,$,$); -#9875=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_33_47','Liquid oxygen cylinders',#9870,$,$); -#9876=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_33_48','Low pressure fire extinguishing gas storage cylinders',#9870,$,$); -#9877=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_33_51','Medical compressed gas cylinders',#9870,$,$); -#9878=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_41','Irrigation and water feature reservoirs',#9853,$,$); -#9879=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_41_41','Integral water features',#9878,$,$); -#9880=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_41_53','Modular irrigation reservoirs',#9878,$,$); -#9881=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_41_65','Pre-formed reservoirs',#9878,$,$); -#9882=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_41_66','Pre-formed rigid pond liners',#9878,$,$); -#9883=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_41_77','Sealed irrigation reservoirs',#9878,$,$); -#9884=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_41_96','Water feature containers',#9878,$,$); -#9885=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_46','Liquid fuel tank accessories',#9853,$,$); -#9886=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_46_45','Liquid fuel tank contents gauges',#9885,$,$); -#9887=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_46_46','Liquid fuel tank drip trays',#9885,$,$); -#9888=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_46_47','Liquid fuel tank fill points',#9885,$,$); -#9889=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_46_48','Liquid fuel tank outflow heaters',#9885,$,$); -#9890=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_46_49','Liquid fuel tank heaters',#9885,$,$); -#9891=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_46_59','Overflow prevention devices',#9885,$,$); -#9892=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_46_87','Tank access chambers',#9885,$,$); -#9893=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_47','Liquid fuel tanks',#9853,$,$); -#9894=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_47_11','Liquid fuel service tanks',#9893,$,$); -#9895=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_47_12','Carbon steel liquid fuel tanks',#9893,$,$); -#9896=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_47_13','Carbon steel oil tanks',#9893,$,$); -#9897=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_47_34','Glass reinforced plastics liquid fuel tanks',#9893,$,$); -#9898=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_47_63','Plastics oil tanks',#9893,$,$); -#9899=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_47_84','Stainless steel liquid fuel tanks',#9893,$,$); -#9900=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_67','Pressure storage vessels',#9853,$,$); -#9901=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_67_31','Foam fire fighting tanks',#9900,$,$); -#9902=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_67_48','Liquefied petroleum gas (LPG) storage vessels',#9900,$,$); -#9903=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_67_52','Metal liquid or gas pressure vessels',#9900,$,$); -#9904=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_67_70','Refrigerant recovery storage vessels',#9900,$,$); -#9905=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_67_93','Vacuum flasks',#9900,$,$); -#9906=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_67_94','Vacuum insulated evaporator (VIE) storage vessels',#9900,$,$); -#9907=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_85','Storage of solid materials',#9853,$,$); -#9908=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_85_01','Above ground storage containers for solid fuel',#9907,$,$); -#9909=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_85_07','Below ground storage containers for solid fuel',#9907,$,$); -#9910=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_85_78','Silos',#9907,$,$); -#9911=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96','Water tanks and cisterns',#9853,$,$); -#9912=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_15','Concrete tanks',#9911,$,$); -#9913=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_20','Cylindrical tanks',#9911,$,$); -#9914=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_32','Galvanized steel cisterns',#9911,$,$); -#9915=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_33','Galvanized steel tanks',#9911,$,$); -#9916=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_34','Glass reinforced plastics cisterns',#9911,$,$); -#9917=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_35','Glass reinforced pressure tanks',#9911,$,$); -#9918=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_36','Glass reinforced plastics tanks',#9911,$,$); -#9919=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_52','Moulded plastics tanks',#9911,$,$); -#9920=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_53','Moulded plastics cisterns',#9911,$,$); -#9921=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_62','Piped attenuation structures',#9911,$,$); -#9922=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_63','Plastics bladder water storage tanks',#9911,$,$); -#9923=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_64','Polyethylene (PE) tanks',#9911,$,$); -#9924=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_65','Polypropylene (PP) tanks',#9911,$,$); -#9925=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_70','Rainwater storage butts',#9911,$,$); -#9926=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_76','Sectional carbon steel tanks',#9911,$,$); -#9927=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_84','Stainless steel tanks',#9911,$,$); -#9928=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55','Liquid and gas source products',#9728,$,$); -#9929=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_31','Inlet connections and fill connections',#9928,$,$); -#9930=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_31_29','Foam inlet adaptors',#9929,$,$); -#9931=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_31_30','Foam inlet boxes',#9929,$,$); -#9932=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_31_42','Riser inlet breechings and boxes',#9929,$,$); -#9933=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_31_47','Liquefied petroleum gas (LPG) fill connections',#9929,$,$); -#9934=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_31_96','Water inlet adaptors',#9929,$,$); -#9935=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_31_97','Water inlet boxes',#9929,$,$); -#9936=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_33','Gas and vacuum generators',#9928,$,$); -#9937=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_33_04','Anaerobic digesters',#9936,$,$); -#9938=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_33_13','Chlorine generators',#9936,$,$); -#9939=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_33_39','Hydrogen generators',#9936,$,$); -#9940=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_33_56','Nitrogen generators',#9936,$,$); -#9941=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_33_73','Pressure swing adsorption (PSA) plant',#9936,$,$); -#9942=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_33_94','Vacuum plant',#9936,$,$); -#9943=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96','Water treatment chemicals',#9928,$,$); -#9944=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_06','Bacteria and biofouling inhibitors',#9943,$,$); -#9945=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_07','Biocide chemicals',#9943,$,$); -#9946=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_08','Biodispersant chemicals',#9943,$,$); -#9947=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_12','Chlorination chemicals',#9943,$,$); -#9948=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_15','Corrosion inhibitor chemicals',#9943,$,$); -#9949=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_16','Corrosion inhibitor chemicals for closed circuits',#9943,$,$); -#9950=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_21','De-chlorination chemicals',#9943,$,$); -#9951=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_22','Dispersant chemicals',#9943,$,$); -#9952=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_58','Odour control chemicals',#9943,$,$); -#9953=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_64','pH correction chemicals',#9943,$,$); -#9954=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_77','Scale inhibitor chemicals',#9943,$,$); -#9955=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_78','Septicity control chemicals',#9943,$,$); -#9956=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_79','Settlement coagulants',#9943,$,$); -#9957=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_96','Water plumbosolvency reduction chemicals',#9943,$,$); -#9958=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97','Water treatment products',#9928,$,$); -#9959=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_02','Alkalinity dosing units',#9958,$,$); -#9960=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_06','Bioaugmentation devices',#9958,$,$); -#9961=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_07','Biocide dosing pots',#9958,$,$); -#9962=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_11','Chemical disinfection devices',#9958,$,$); -#9963=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_12','Chemical dosing pots',#9958,$,$); -#9964=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_13','Chemical injectors',#9958,$,$); -#9965=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_14','Clarifiers',#9958,$,$); -#9966=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_15','Coagulant dosing units',#9958,$,$); -#9967=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_20','Deionization units',#9958,$,$); -#9968=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_21','Desalination units',#9958,$,$); -#9969=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_22','Disinfectant dosing units',#9958,$,$); -#9970=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_23','Distillation units',#9958,$,$); -#9971=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_24','Drinking water nitrate removal devices',#9958,$,$); -#9972=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_27','Electrodialysis units',#9958,$,$); -#9973=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_41','Inline filter units',#9958,$,$); -#9974=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_43','Ion exchange demineralization units',#9958,$,$); -#9975=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_44','Ion exchange softening units',#9958,$,$); -#9976=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_50','Magnetic water conditioners',#9958,$,$); -#9977=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_63','pH control dosing units',#9958,$,$); -#9978=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_72','Reverse osmosis units',#9958,$,$); -#9979=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_85','Sterilizers',#9958,$,$); -#9980=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_86','Surface skimmers',#9958,$,$); -#9981=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_93','Ultraviolet (UV) disinfection devices',#9958,$,$); -#9982=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_95','Water aerators',#9958,$,$); -#9983=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_96','Water conditioners',#9958,$,$); -#9984=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_97','Water treatment dosing pots',#9958,$,$); -#9985=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60','Heating and cooling source products',#9728,$,$); -#9986=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08','Boilers',#9985,$,$); -#9987=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_08','Biomass boilers',#9986,$,$); -#9988=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_24','Dual fuel cast iron boilers',#9986,$,$); -#9989=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_25','Dual fuel steel shell boilers',#9986,$,$); -#9990=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_27','Electric boilers',#9986,$,$); -#9991=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_33','Gas fired boilers',#9986,$,$); -#9992=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_34','Gas fired condensing boilers',#9986,$,$); -#9993=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_35','Gas fired cast iron boilers',#9986,$,$); -#9994=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_36','Gas fired steel shell boilers',#9986,$,$); -#9995=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_37','Gas fired water tube boilers',#9986,$,$); -#9996=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_56','Oil fired condensing boilers',#9986,$,$); -#9997=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_57','Oil fired non-condensing boilers',#9986,$,$); -#9998=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_58','Oil fired cast iron boilers',#9986,$,$); -#9999=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_59','Oil fired steel shell boilers',#9986,$,$); -#10000=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_60','Oil fired water tube boilers',#9986,$,$); -#10001=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_80','Solid fuel cast iron boilers',#9986,$,$); -#10002=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_81','Solid fuel steel shell boilers',#9986,$,$); -#10003=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_83','Submerged panel heat exchangers',#9986,$,$); -#10004=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_84','Submerged pipe heat exchangers',#9986,$,$); -#10005=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_10','Burners',#9985,$,$); -#10006=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_10_03','Atmospheric gas burners',#10005,$,$); -#10007=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_10_05','Atomizing oil burners',#10005,$,$); -#10008=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_10_29','Forced draught dual fuel burners',#10005,$,$); -#10009=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_10_30','Forced draught gas burners',#10005,$,$); -#10010=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_10_31','Forced draught oil burners',#10005,$,$); -#10011=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_10_65','Pre-mix gas burners',#10005,$,$); -#10012=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_13','Chillers and cooling towers',#9985,$,$); -#10013=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_13_01','Adsorption chillers',#10012,$,$); -#10014=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_13_02','Adiabatic chillers',#10012,$,$); -#10015=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_13_04','Air cooled liquid chillers',#10012,$,$); -#10016=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_13_14','Closed circuit cooling towers',#10012,$,$); -#10017=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_13_22','Direct fired absorption liquid chillers',#10012,$,$); -#10018=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_13_27','Electric driven refrigerant compressors',#10012,$,$); -#10019=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_13_33','Gas engine driven refrigerant compressors',#10012,$,$); -#10020=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_13_38','Hot water fired absorption liquid chillers',#10012,$,$); -#10021=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_13_59','Open circuit cooling towers',#10012,$,$); -#10022=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_13_84','Steam fired absorption liquid chillers',#10012,$,$); -#10023=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_13_96','Water cooled liquid chillers',#10012,$,$); -#10024=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_36','Heat recovery distribution equipment',#9985,$,$); -#10025=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_36_26','Economizers',#10024,$,$); -#10026=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_36_36','Heat pipes',#10024,$,$); -#10027=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_36_60','Passive heat exchangers',#10024,$,$); -#10028=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_36_62','Plate recuperators',#10024,$,$); -#10029=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_36_72','Regenerators',#10024,$,$); -#10030=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_36_74','Run-around coils',#10024,$,$); -#10031=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_36_88','Thermal wheels',#10024,$,$); -#10032=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_38','Calorifiers and plate heat exchangers',#9985,$,$); -#10033=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_38_36','Heat interface units',#10032,$,$); -#10034=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_38_38','Hot water non-storage calorifiers',#10032,$,$); -#10035=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_38_42','Instantaneous plate heat exchangers',#10032,$,$); -#10036=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_38_62','Plate heat exchangers',#10032,$,$); -#10037=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_38_84','Steam to water non-storage calorifiers',#10032,$,$); -#10038=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_38_85','Storage calorifiers',#10032,$,$); -#10039=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_81','Solar heat collectors',#9985,$,$); -#10040=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_81_26','Evacuated tube solar collectors',#10039,$,$); -#10041=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_81_30','Flat plate solar collectors',#10039,$,$); -#10042=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_81_80','Solar heat stores',#10039,$,$); -#10043=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_81_81','Solar trackers',#10039,$,$); -#10044=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_83','Solid fuel and waste handling equipment',#9985,$,$); -#10045=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_83_05','Ash handling equipment',#10044,$,$); -#10046=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_83_81','Solid fuel handling equipment',#10044,$,$); -#10047=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_84','Steam generators',#9985,$,$); -#10048=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_84_14','Clean steam generators',#10047,$,$); -#10049=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_96','Water heaters',#9985,$,$); -#10050=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_96_26','Electric instantaneous shower units',#10049,$,$); -#10051=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_96_27','Electric instantaneous water heaters',#10049,$,$); -#10052=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_96_28','Electric storage water heaters',#10049,$,$); -#10053=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_96_31','Gas-fired condensing water heaters',#10049,$,$); -#10054=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_96_33','Gas-fired instantaneous water heaters',#10049,$,$); -#10055=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_96_34','Gas-fired storage water heaters',#10049,$,$); -#10056=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_96_42','Immersion heaters',#10049,$,$); -#10057=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65','Air and fume source products',#9728,$,$); -#10058=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_03','Air handling units',#10057,$,$); -#10059=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_03_28','Extract and return air handling units',#10058,$,$); -#10060=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_03_86','Supply air handling units',#10058,$,$); -#10061=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_03_87','Supply and return air handling units',#10058,$,$); -#10062=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_31','Fume cupboards and safety cabinets',#10057,$,$); -#10063=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_31_33','General-purpose fume cupboards',#10062,$,$); -#10064=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_31_46','Laminar flow cabinets',#10062,$,$); -#10065=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_31_52','Microbiological safety cabinets',#10062,$,$); -#10066=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_31_71','Recirculatory filtration fume cupboards',#10062,$,$); -#10067=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_31_76','School fume cupboards',#10062,$,$); -#10068=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_31_94','Variable air volume fume cupboards',#10062,$,$); -#10069=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_37','Heating and cooling coils',#10057,$,$); -#10070=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_37_12','Chilled water cooling coils',#10069,$,$); -#10071=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_37_27','Electric heater batteries',#10069,$,$); -#10072=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_37_33','Gas fired heater batteries',#10069,$,$); -#10073=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_37_41','Intercoolers',#10069,$,$); -#10074=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_37_47','Low temperature hot water heating coils',#10069,$,$); -#10075=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_37_72','Refrigerant cooling coils',#10069,$,$); -#10076=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_94','Ventilation hoods and extract points',#10057,$,$); -#10077=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_94_29','Fume capturing hoods',#10076,$,$); -#10078=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_94_30','Fume enclosing hoods',#10076,$,$); -#10079=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_94_31','Fume receiving hoods',#10076,$,$); -#10080=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_94_32','Fume extract points',#10076,$,$); -#10081=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_94_45','Kitchen canopies',#10076,$,$); -#10082=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_94_46','Kitchen extractor hoods',#10076,$,$); -#10083=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_94_94','Vehicle exhaust nozzles',#10076,$,$); -#10084=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70','Power supply products',#9728,$,$); -#10085=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_06','Batteries and chargers',#10084,$,$); -#10086=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_06_05','Automatic battery chargers',#10085,$,$); -#10087=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_06_06','Backup battery supply',#10085,$,$); -#10088=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_06_12','Central battery supply units',#10085,$,$); -#10089=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_06_23','Direct current battery charge controllers',#10085,$,$); -#10090=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_06_27','Electric vehicle chargers',#10085,$,$); -#10091=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_06_67','PV generator junction boxes',#10085,$,$); -#10092=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_06_71','Rechargeable dry cell battery chargers',#10085,$,$); -#10093=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_06_76','Sealed lead acid batteries',#10085,$,$); -#10094=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_06_77','Sealed nickel cadmium batteries',#10085,$,$); -#10095=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_06_94','Valve regulated (sealed) lead acid',#10085,$,$); -#10096=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_06_95','Vented lead acid batteries',#10085,$,$); -#10097=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_06_96','Vented nickel cadmium batteries',#10085,$,$); -#10098=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_22','Distribution boxes and switchboards',#10084,$,$); -#10099=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_22_11','Cable distribution cabinets',#10098,$,$); -#10100=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_22_15','Consumer units',#10098,$,$); -#10101=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_22_19','Cubicle switchboards',#10098,$,$); -#10102=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_22_22','Distribution boards',#10098,$,$); -#10103=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_22_28','Extension boxes',#10098,$,$); -#10104=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_22_46','Lighting distribution boxes',#10098,$,$); -#10105=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_22_50','Master distribution boxes',#10098,$,$); -#10106=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_22_79','Slave distribution boxes',#10098,$,$); -#10107=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_22_80','Spreader boxes',#10098,$,$); -#10108=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_22_85','Sub-main distribution boards',#10098,$,$); -#10109=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_28','Extra high voltage switchgear',#10084,$,$); -#10110=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36','High voltage switchgear and transformers',#10084,$,$); -#10111=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_06','High voltage busbar metering panels',#10110,$,$); -#10112=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_07','High voltage bus-section panels',#10110,$,$); -#10113=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_12','High voltage circuit breakers',#10110,$,$); -#10114=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_18','High voltage current transformers',#10110,$,$); -#10115=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_22','High voltage disconnectors',#10110,$,$); -#10116=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_24','High voltage dry type transformers',#10110,$,$); -#10117=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_26','High voltage earthing switches',#10110,$,$); -#10118=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_30','High voltage liquid immersed transformers',#10110,$,$); -#10119=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_37','High voltage fuses',#10110,$,$); -#10120=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_53','High voltage modular switchboards',#10110,$,$); -#10121=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_70','High voltage rectiformers',#10110,$,$); -#10122=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_72','High voltage ring main units',#10110,$,$); -#10123=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_75','High voltage safety matting',#10110,$,$); -#10124=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_80','High voltage switch-disconnectors',#10110,$,$); -#10125=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_81','High voltage switch-fuse combinations',#10110,$,$); -#10126=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_82','High voltage switches',#10110,$,$); -#10127=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_83','High voltage switchgear protection and control modules',#10110,$,$); -#10128=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_94','High voltage vacuum circuit breaker panels',#10110,$,$); -#10129=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48','Low voltage switchgear',#10084,$,$); -#10130=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_05','Automatic transfer switching equipment (TSE)',#10129,$,$); -#10131=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_06','Busbar chambers',#10129,$,$); -#10132=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_07','Busbar trunking feed units',#10129,$,$); -#10133=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_08','Busbar trunking fire barrier units',#10129,$,$); -#10134=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_09','Busbar trunking tap-off units',#10129,$,$); -#10135=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_11','Changeover switches',#10129,$,$); -#10136=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_27','Electrical cut-outs',#10129,$,$); -#10137=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_30','Fireman\X2\2019\X0\s emergency switches',#10129,$,$); -#10138=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_44','Low voltage fuse-switch disconnectors',#10129,$,$); -#10139=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_45','Low voltage safety matting',#10129,$,$); -#10140=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_46','Low voltage switch-disconnector fuses',#10129,$,$); -#10141=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_47','Low voltage switch disconnectors',#10129,$,$); -#10142=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_48','Low voltage switches',#10129,$,$); -#10143=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_49','Low voltage switchgear tripping units',#10129,$,$); -#10144=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_62','Photovoltaic array junction boxes',#10129,$,$); -#10145=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_63','Photovoltaic generator junction boxes',#10129,$,$); -#10146=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_66','Power busbar trunking',#10129,$,$); -#10147=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_64','Power conditioning supply equipment',#10084,$,$); -#10148=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_64_86','Static inverter power supply units',#10147,$,$); -#10149=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_64_93','Uninterruptible power supply (UPS) units',#10147,$,$); -#10150=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_64_94','Uninterruptible power supply (UPS) remote alarm panels',#10147,$,$); -#10151=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65','Power generators, engines and packaged combined heat and power (CHP) units',#10084,$,$); -#10152=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_03','Alternators',#10151,$,$); -#10153=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_05','Automatic voltage regulators',#10151,$,$); -#10154=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_32','Gas turbines (CCGT)',#10151,$,$); -#10155=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_33','Generator control panels',#10151,$,$); -#10156=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_34','Generator sets',#10151,$,$); -#10157=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_35','Governors',#10151,$,$); -#10158=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_37','Horizontal axis wind turbines (HAWT)',#10151,$,$); -#10159=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_38','Hydraulic power units',#10151,$,$); -#10160=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_39','Hydro turbines',#10151,$,$); -#10161=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_41','Internal combustion engines',#10151,$,$); -#10162=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_47','Load banks',#10151,$,$); -#10163=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_58','Offshore wind turbines',#10151,$,$); -#10164=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_59','Onshore wind turbines',#10151,$,$); -#10165=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_60','Packaged combined heat and power (CHP) units',#10151,$,$); -#10166=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_63','Photovoltaic modules',#10151,$,$); -#10167=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_94','Vertical axis wind turbines (VAWT)',#10151,$,$); -#10168=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_97','Wind turbine controllers',#10151,$,$); -#10169=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75','Communications source products',#9728,$,$); -#10170=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_01','Antennas and satellite dishes',#10169,$,$); -#10171=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_01_22','Digital audio broadcasting (DAB) antennas',#10170,$,$); -#10172=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_01_31','Frequency modulation (FM) antennas',#10170,$,$); -#10173=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_01_75','Satellite dishes',#10170,$,$); -#10174=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_01_92','Ultra-high frequency (UHF) antennas',#10170,$,$); -#10175=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_03','Audio and video players and recorders',#10169,$,$); -#10176=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_03_07','Blu-ray players',#10175,$,$); -#10177=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_03_11','Cassette players',#10175,$,$); -#10178=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_03_15','Compact disc players',#10175,$,$); -#10179=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_03_22','Digital video recorders',#10175,$,$); -#10180=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_03_56','Network video recorders',#10175,$,$); -#10181=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_03_70','Radio tuners',#10175,$,$); -#10182=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_03_87','Time lapse video recorders',#10175,$,$); -#10183=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_06','Audio input devices',#10169,$,$); -#10184=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_06_53','Microphones',#10183,$,$); -#10185=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_06_60','Paging consoles',#10183,$,$); -#10186=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08','Audio and visual source products',#10169,$,$); -#10187=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_01','Artificial reverberation, time delay and frequency shift equipment',#10186,$,$); -#10188=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_02','Audio amplifiers',#10186,$,$); -#10189=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_03','Audio equalizers',#10186,$,$); -#10190=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_04','Automatic announcement equipment',#10186,$,$); -#10191=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_05','Auxiliary passive elements',#10186,$,$); -#10192=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_21','Digital broadcast signal router multiswitches',#10186,$,$); -#10193=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_23','Diplexers',#10186,$,$); -#10194=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_28','External source input points',#10186,$,$); -#10195=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_46','Launch amplifiers',#10186,$,$); -#10196=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_48','Local volume controls',#10186,$,$); -#10197=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_50','Masthead amplifiers',#10186,$,$); -#10198=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_52','Mixer amplifiers',#10186,$,$); -#10199=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_54','Mixers',#10186,$,$); -#10200=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_55','Multiswitches',#10186,$,$); -#10201=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_63','Pre-amplifiers',#10186,$,$); -#10202=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_71','Remote microphone input points',#10186,$,$); -#10203=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_78','Splitters',#10186,$,$); -#10204=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_78','Signal transmitters',#10169,$,$); -#10205=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_78_85','Supervised premises transceivers',#10204,$,$); -#10206=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_78_91','Television equalizers',#10204,$,$); -#10207=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86','Surveillance cameras, monitors and ancillaries',#10169,$,$); -#10208=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_01','Automatic number plate recognition cameras',#10207,$,$); -#10209=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_02','Analogue box cameras',#10207,$,$); -#10210=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_03','Analogue bullet cameras',#10207,$,$); -#10211=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_04','Analogue covert cameras',#10207,$,$); -#10212=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_05','Analogue fixed dome cameras',#10207,$,$); -#10213=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_06','Analogue pan, tilt, zoom (PTZ) cameras',#10207,$,$); -#10214=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_07','Box cameras',#10207,$,$); -#10215=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_08','Box camera lenses',#10207,$,$); -#10216=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_09','Bullet cameras',#10207,$,$); -#10217=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_10','Camera junction boxes',#10207,$,$); -#10218=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_11','Covert cameras',#10207,$,$); -#10219=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_21','Day night cameras',#10207,$,$); -#10220=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_24','Dome cameras',#10207,$,$); -#10221=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_30','Fixed cameras',#10207,$,$); -#10222=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_31','Fixed dome cameras',#10207,$,$); -#10223=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_40','Image processing units',#10207,$,$); -#10224=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_41','Infra-red cameras',#10207,$,$); -#10225=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_42','Infrared illuminators',#10207,$,$); -#10226=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_45','Integrated digital camera and infrared illuminators',#10207,$,$); -#10227=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_47','Lenses',#10207,$,$); -#10228=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_60','Pan and tilt units',#10207,$,$); -#10229=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_65','Pan, tilt, zoom cameras',#10207,$,$); -#10230=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_79','Surveillance monitors',#10207,$,$); -#10231=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_80','Survey cameras',#10207,$,$); -#10232=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_90','Traffic enforcement cameras',#10207,$,$); -#10233=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_92','Video distribution amplifiers',#10207,$,$); -#10234=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_94','Video receiver hubs',#10207,$,$); -#10235=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_99','Zoom lenses',#10207,$,$); -#10236=IFCCLASSIFICATIONREFERENCE($,'Pr_65','Services distribution products',#4921,$,$); -#10237=IFCCLASSIFICATIONREFERENCE($,'Pr_65_12','Chutes',#10236,$,$); -#10238=IFCCLASSIFICATIONREFERENCE($,'Pr_65_12_70','Refuse and linen chutes',#10237,$,$); -#10239=IFCCLASSIFICATIONREFERENCE($,'Pr_65_12_70_22','Disposal chutes',#10238,$,$); -#10240=IFCCLASSIFICATIONREFERENCE($,'Pr_65_12_70_47','Linen chutes',#10238,$,$); -#10241=IFCCLASSIFICATIONREFERENCE($,'Pr_65_12_71','Refuse and linen chute accessories',#10237,$,$); -#10242=IFCCLASSIFICATIONREFERENCE($,'Pr_65_12_71_12','Chute cleaning mechanisms',#10241,$,$); -#10243=IFCCLASSIFICATIONREFERENCE($,'Pr_65_12_71_72','Refuse and recycling separators',#10241,$,$); -#10244=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50','Gutter and fitting products',#10236,$,$); -#10245=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35','Gutters and accessories',#10244,$,$); -#10246=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_02','Aluminium combined fascias, soffits and gutters',#10245,$,$); -#10247=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_04','Aluminium composite valley gutters',#10245,$,$); -#10248=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_06','Aluminium eaves gutters',#10245,$,$); -#10249=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_08','Aluminium valley gutters',#10245,$,$); -#10250=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_09','Box gutter sumps',#10245,$,$); -#10251=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_11','Cast iron eaves gutters',#10245,$,$); -#10252=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_15','Copper eaves gutters',#10245,$,$); -#10253=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_26','Eaves gutter leaf guards',#10245,$,$); -#10254=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_27','Galvanized steel valley gutters',#10245,$,$); -#10255=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_28','Galvanized steel chambered gutters',#10245,$,$); -#10256=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_29','Galvanized steel combined fascias, soffits and gutters',#10245,$,$); -#10257=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_30','Galvanized steel composite gutters',#10245,$,$); -#10258=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_31','Galvanized steel eaves gutters',#10245,$,$); -#10259=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_33','Glass reinforced plastics (GRP) valley gutters',#10245,$,$); -#10260=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_34','Glass reinforced plastics (GRP) composite valley gutters',#10245,$,$); -#10261=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_35','Glass reinforced plastics (GRP) eaves gutters',#10245,$,$); -#10262=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_36','Glass reinforced plastics (GRP) roof gutters',#10245,$,$); -#10263=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_37','Gravity rainwater outlets',#10245,$,$); -#10264=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_38','Gutter linings',#10245,$,$); -#10265=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_40','Hot dip precoated carbon steel combined fascias, soffits and gutters',#10245,$,$); -#10266=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_42','Hot dip precoated carbon steel eaves gutters',#10245,$,$); -#10267=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_43','Hot dip precoated carbon steel valley gutters',#10245,$,$); -#10268=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_47','Lead rainwater chutes',#10245,$,$); -#10269=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_68','Rainwater hoppers',#10245,$,$); -#10270=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_70','Rainwater pipe diverter units',#10245,$,$); -#10271=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_72','Rainwater weirs',#10245,$,$); -#10272=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_81','Siphonic rainwater outlets',#10245,$,$); -#10273=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_82','Stainless steel eaves gutters',#10245,$,$); -#10274=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_83','Stainless steel rainwater chutes',#10245,$,$); -#10275=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_84','Stainless steel valley gutters',#10245,$,$); -#10276=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_92','Unplasticized polyvinyl chloride (PVC-U) eaves gutters',#10245,$,$); -#10277=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_98','Zinc eaves gutters',#10245,$,$); -#10278=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_99','Zinc rainwater chutes',#10245,$,$); -#10279=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52','Pipe, tube and fitting products',#10236,$,$); -#10280=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01','Access and inspection chambers and gullies',#10279,$,$); -#10281=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_01','Access and inspection chambers',#10280,$,$); -#10282=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_02','Access covers and frames',#10280,$,$); -#10283=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_03','Access gratings',#10280,$,$); -#10284=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_04','Aluminium inspection chambers',#10280,$,$); -#10285=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_08','Carbon steel edge strips and frames',#10280,$,$); -#10286=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_09','Carbon steel inspection chambers',#10280,$,$); -#10287=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_14','Concrete access cover seatings',#10280,$,$); -#10288=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_16','Concrete inspection chamber sections',#10280,$,$); -#10289=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_17','Concrete inspection chamber cover slabs',#10280,$,$); -#10290=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_18','Concrete inspection chamber shaft sections',#10280,$,$); -#10291=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_19','Concrete inspection chamber transition sections',#10280,$,$); -#10292=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_20','Concrete manhole base units',#10280,$,$); -#10293=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_21','Concrete manhole chamber sections',#10280,$,$); -#10294=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_22','Concrete manhole shaft sections',#10280,$,$); -#10295=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_23','Concrete manhole transition sections',#10280,$,$); -#10296=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_24','Concrete manholes and soakaway cover slabs',#10280,$,$); -#10297=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_25','Concrete soakaway shaft sections',#10280,$,$); -#10298=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_50','Manhole covers and frames',#10280,$,$); -#10299=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_58','Orifice plate drainage flow controllers',#10280,$,$); -#10300=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_60','Plastics access and inspection chambers',#10280,$,$); -#10301=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_61','Plastics below-ground access or equipment chambers',#10280,$,$); -#10302=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_62','Plastics channels for access chambers',#10280,$,$); -#10303=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_63','Plastics distribution and sampling chambers',#10280,$,$); -#10304=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_64','Plastics inspection chambers',#10280,$,$); -#10305=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_65','Plastics mini inspection chambers',#10280,$,$); -#10306=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_66','Plastics restricted access inspection shafts',#10280,$,$); -#10307=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_67','Plastics sealed access pipes',#10280,$,$); -#10308=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_68','Preformed access ducts',#10280,$,$); -#10309=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_72','Recycled polyethylene (PE) inspection chambers',#10280,$,$); -#10310=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_83','Stainless steel edge strips and frames',#10280,$,$); -#10311=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_84','Stainless steel inspection chambers',#10280,$,$); -#10312=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_86','Surface boxes',#10280,$,$); -#10313=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_95','Vortex flow drainage controllers',#10280,$,$); -#10314=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07','Below-ground and pressure drainage pipes and fittings',#10279,$,$); -#10315=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_13','Clay below-ground drainage pipes and fittings',#10314,$,$); -#10316=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_15','Concrete perforated below-ground drainage pipes and fittings for flexible jointing',#10314,$,$); -#10317=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_16','Concrete plain wall below-ground drainage pipes and fittings for flexible jointing',#10314,$,$); -#10318=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_25','Ductile iron pressure pipes and fittings',#10314,$,$); -#10319=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_27','Filtration drainage pipes and fittings',#10314,$,$); -#10320=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_28','Flexible couplings between below-ground drainage pipes',#10314,$,$); -#10321=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_34','Grey cast iron below-ground drainage pipes and fittings',#10314,$,$); -#10322=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_36','High-density polyethylene (HDPE) pressure pipes and fittings',#10314,$,$); -#10323=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_38','High-density polyethylene (HDPE) structured wall below-ground drainage pipes and fittings for flexible jointing',#10314,$,$); -#10324=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_39','High-density polyethylene (HDPE) structured wall below-ground drainage pipes and fittings for welded jointing',#10314,$,$); -#10325=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_40','High-density polyethylene (HDPE) structured wall perforated below-ground drainage pipes and fittings for flexible jointing',#10314,$,$); -#10326=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_58','Oriented unplasticized polyvinyl chloride (PVC-O) pressure pipes and fittings',#10314,$,$); -#10327=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_63','Plastics flexible (coil) perforated wall below-ground drainage pipes and fittings',#10314,$,$); -#10328=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_64','Polypropylene (PP) solid wall below-ground drainage pipes and fittings for flexible jointing',#10314,$,$); -#10329=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_65','Polypropylene (PP) structured wall below-ground drainage pipes and fittings for flexible jointing',#10314,$,$); -#10330=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_66','Polypropylene (PP) structured wall perforated below-ground drainage pipes and fittings for flexible jointing',#10314,$,$); -#10331=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_67','Polypropylene (PP) structured wall below-ground drainage pipes and fittings for welded jointing',#10314,$,$); -#10332=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_75','Saddle connectors to below-ground drainage pipes',#10314,$,$); -#10333=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_84','Steel reinforced polyethylene composite structured wall below ground drainage pipelines for flexible jointing',#10314,$,$); -#10334=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_87','Unplasticized polyvinyl chloride (PVC-U) pressure pipes and fittings',#10314,$,$); -#10335=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_88','Unplasticized polyvinyl chloride (PVC-U) solid wall below-ground drainage pipe and fittings for flexible jointing',#10314,$,$); -#10336=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_89','Unplasticized polyvinyl chloride (PVC-U) solid wall perforated below-ground drainage pipes and fittings for flexible jointing',#10314,$,$); -#10337=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_90','Unplasticized polyvinyl chloride (PVC-U) structured wall below-ground drainage pipes and fittings for flexible jointing',#10314,$,$); -#10338=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_91','Unplasticized polyvinyl chloride (PVC-U) structured wall perforated below-ground drainage pipe and fittings for flexible jointing',#10314,$,$); -#10339=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_92','Unplasticized polyvinyl chloride alloy (PVC-A) pressure pipes and fittings',#10314,$,$); -#10340=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_94','Vitrified clay perforated below-ground drainage pipes and fittings for flexible jointing',#10314,$,$); -#10341=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_96','Vitrified clay plain wall below-ground drainage open butt joint pipes (land drainage tiles) and fittings',#10314,$,$); -#10342=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_97','Vitrified clay plain wall below-ground drainage pipes and fittings for flexible jointing',#10314,$,$); -#10343=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_98','Vitrified clay plain wall below-ground drainage pipes and fittings for rigid jointing',#10314,$,$); -#10344=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_20','Culverts',#10279,$,$); -#10345=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_20_15','Concrete arch culverts',#10344,$,$); -#10346=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_20_16','Concrete box culverts',#10344,$,$); -#10347=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_20_17','Concrete bridge culverts',#10344,$,$); -#10348=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_20_18','Concrete pipe arch culverts',#10344,$,$); -#10349=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_20_19','Concrete pipe culverts',#10344,$,$); -#10350=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_20_20','Corrugated steel pipe culverts',#10344,$,$); -#10351=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_20_84','Structural plate corrugated steel pipe culverts',#10344,$,$); -#10352=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24','Drainage gullies and channels',#10279,$,$); -#10353=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_02','Adaptors for above-ground pipe connections to clay drainage pipelines',#10352,$,$); -#10354=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_03','Adaptors for above-ground pipe connections to plastics drainage pipelines',#10352,$,$); -#10355=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_11','Carriageway kerb and drainage channels',#10352,$,$); -#10356=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_12','Cast iron composite gullies',#10352,$,$); -#10357=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_13','Cast iron one piece gullies',#10352,$,$); -#10358=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_14','Cast iron rodding eyes',#10352,$,$); -#10359=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_15','Cast iron sealed access pipes',#10352,$,$); -#10360=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_18','Concrete one piece gullies',#10352,$,$); -#10361=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_24','Drainage channels with gratings',#10352,$,$); -#10362=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_26','Filtration drainage channels',#10352,$,$); -#10363=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_28','Floor channels',#10352,$,$); -#10364=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_29','Floor channel covers and gratings',#10352,$,$); -#10365=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_30','Floor gully covers and gratings',#10352,$,$); -#10366=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_31','Floor gullies',#10352,$,$); -#10367=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_47','Linear slot drainage channels',#10352,$,$); -#10368=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_59','Plastics composite gullies',#10352,$,$); -#10369=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_60','Plastics one piece gullies',#10352,$,$); -#10370=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_61','Plastics rodding eyes',#10352,$,$); -#10371=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_64','Polypropylene (PP) composite gullies',#10352,$,$); -#10372=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_65','Polypropylene (PP) one piece gullies',#10352,$,$); -#10373=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_73','Rat barrier pipes',#10352,$,$); -#10374=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_85','Stainless steel rodding eyes',#10352,$,$); -#10375=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_91','Vitrified clay access chamber channels',#10352,$,$); -#10376=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_92','Vitrified clay composite gullies',#10352,$,$); -#10377=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_94','Vitrified clay one piece gullies',#10352,$,$); -#10378=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_95','Vitrified clay rodding eyes',#10352,$,$); -#10379=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_96','Vitrified clay sealed access pipes',#10352,$,$); -#10380=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25','Drainage traps and accessories',#10279,$,$); -#10381=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25_06','Below-ground grease traps and converters',#10380,$,$); -#10382=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25_15','Concrete silt traps',#10380,$,$); -#10383=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25_23','Depressurization sumps',#10380,$,$); -#10384=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25_27','Enzyme dosing units',#10380,$,$); -#10385=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25_32','Free-standing grease traps and converters',#10380,$,$); -#10386=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25_60','Petrol interceptors',#10380,$,$); -#10387=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25_62','Plastics silt traps',#10380,$,$); -#10388=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25_72','Reverse action interceptors',#10380,$,$); -#10389=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25_75','Sanitary appliance traps',#10380,$,$); -#10390=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25_78','Silt buckets',#10380,$,$); -#10391=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25_93','Vitrified clay interceptor traps',#10380,$,$); -#10392=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25_96','Vitrified clay silt traps',#10380,$,$); -#10393=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25_98','Waste traps',#10380,$,$); -#10394=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34','Gauges and sight glasses',#10279,$,$); -#10395=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34_08','Bourdon tube pressure gauges',#10394,$,$); -#10396=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34_15','Combined steam sight glass and check valves',#10394,$,$); -#10397=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34_16','Contents gauges',#10394,$,$); -#10398=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34_18','Contents sight glasses',#10394,$,$); -#10399=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34_22','Differential pressure gauges',#10394,$,$); -#10400=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34_24','Double window steam sight glasses',#10394,$,$); -#10401=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34_48','Manifold gauges',#10394,$,$); -#10402=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34_50','Manometers',#10394,$,$); -#10403=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34_55','Multi window steam sight glasses',#10394,$,$); -#10404=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34_65','Pressure and altitude gauges',#10394,$,$); -#10405=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34_66','Pressure gauges',#10394,$,$); -#10406=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34_77','Single window steam sight glasses',#10394,$,$); -#10407=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34_88','Temperature gauges',#10394,$,$); -#10408=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38','Hoses, hose reels and ancillaries',#10279,$,$); -#10409=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_14','Compressed air coil hoses',#10408,$,$); -#10410=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_15','Compressed air hose couplings',#10408,$,$); -#10411=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_16','Compressed air hose reel balancers',#10408,$,$); -#10412=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_18','Compressed air hose reels',#10408,$,$); -#10413=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_20','Crushproof vehicle exhaust hoses',#10408,$,$); -#10414=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_30','Fire hose reels',#10408,$,$); -#10415=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_31','Flat irrigation hoses',#10408,$,$); -#10416=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_32','Foam hose couplings',#10408,$,$); -#10417=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_33','Gas hose reels',#10408,$,$); -#10418=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_42','Irrigation hoses',#10408,$,$); -#10419=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_48','Liquid petroleum gas (LPG) rubber hoses and hose assemblies',#10408,$,$); -#10420=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_69','Quick release couplings',#10408,$,$); -#10421=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_71','Reinforced wall hoses',#10408,$,$); -#10422=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_84','Spiral compressed air hoses',#10408,$,$); -#10423=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_85','Spiral plastics hoses',#10408,$,$); -#10424=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_86','Spring balancer vehicle exhaust hose supports',#10408,$,$); -#10425=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_94','Vehicle exhaust hose reels',#10408,$,$); -#10426=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_95','Water hose reels',#10408,$,$); -#10427=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_96','Water hoses',#10408,$,$); -#10428=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_97','Water fire extinguishing hose couplings',#10408,$,$); -#10429=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_98','WC washdown hoses',#10408,$,$); -#10430=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61','Pipe accessories',#10279,$,$); -#10431=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_04','Anti-climb pipe covers',#10430,$,$); -#10432=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_15','Concealed intumescent pipe collars',#10430,$,$); -#10433=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_22','Dirt pockets',#10430,$,$); -#10434=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_23','Discharge and ventilating stack terminations',#10430,$,$); -#10435=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_42','Insulated wrap pipe collars',#10430,$,$); -#10436=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_50','Masking plates',#10430,$,$); -#10437=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_61','Pipe ducts',#10430,$,$); -#10438=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_62','Pipeline supports',#10430,$,$); -#10439=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_63','Pipe sleeves',#10430,$,$); -#10440=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_64','Pipe sleeve seals',#10430,$,$); -#10441=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_65','Plastics ducts for electric cables',#10430,$,$); -#10442=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_68','Puddle flanges',#10430,$,$); -#10443=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_72','Radiator pipe seals',#10430,$,$); -#10444=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_86','Surface-mounted intumescent pipe collars',#10430,$,$); -#10445=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_91','Tundishes',#10430,$,$); -#10446=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_96','Wall collars',#10430,$,$); -#10447=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62','Pipe jointing materials',#10279,$,$); -#10448=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_03','Anaerobic sealants',#10447,$,$); -#10449=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_09','Brazing compounds',#10447,$,$); -#10450=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_11','Caulking ropes',#10447,$,$); -#10451=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_25','Elastomeric pipe joint gaskets',#10447,$,$); -#10452=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_27','Elastomeric ring seals',#10447,$,$); -#10453=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_28','Flange adaptors',#10447,$,$); -#10454=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_29','Flange jointing rings for copper flanges',#10447,$,$); -#10455=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_30','Flange jointing rings for stainless steel flanges',#10447,$,$); -#10456=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_31','Flange jointing rings for steel flanges',#10447,$,$); -#10457=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_32','Flux',#10447,$,$); -#10458=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_36','Hemps and pastes',#10447,$,$); -#10459=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_50','Mechanical couplings',#10447,$,$); -#10460=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_62','Pipeline connectors',#10447,$,$); -#10461=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_65','Polytetrafluoroethylene (PTFE) joint tapes',#10447,$,$); -#10462=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_71','Resin modified cements',#10447,$,$); -#10463=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_81','Solders',#10447,$,$); -#10464=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_82','Solvent welding cements',#10447,$,$); -#10465=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63','Pipes and fittings',#10279,$,$); -#10466=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_02','Acrylonitrile butadiene styrene (ABS) pipes and fittings',#10465,$,$); -#10467=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_03','Acrylonitrile butadiene styrene (ABS) fittings',#10465,$,$); -#10468=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_04','Aluminium rainwater pipe and fittings',#10465,$,$); -#10469=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_08','Borosilicate glass pipe and fittings',#10465,$,$); -#10470=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_10','Carbon steel pipe and fittings',#10465,$,$); -#10471=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_11','Cast iron rainwater pipe and fittings',#10465,$,$); -#10472=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_12','Cast iron drainage pipe and fittings',#10465,$,$); -#10473=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_13','Chlorinated polyvinyl chloride (PVC-C) pipe and fittings',#10465,$,$); -#10474=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_14','Chlorinated polyvinyl chloride (PVC-C) pipelines',#10465,$,$); -#10475=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_15','Concrete perforated pipes and fittings',#10465,$,$); -#10476=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_16','Concrete pipes and fittings',#10465,$,$); -#10477=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_17','Copper pipelines',#10465,$,$); -#10478=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_18','Copper pipeline fittings',#10465,$,$); -#10479=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_19','Copper rainwater pipes and fittings',#10465,$,$); -#10480=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_20','Copper refrigerant pipelines',#10465,$,$); -#10481=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_21','Copper waste water pipe and fittings',#10465,$,$); -#10482=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_22','Corrugated stainless steel pipes and fittings',#10465,$,$); -#10483=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_23','Cross-linked polyethylene (PE-X) pipes and fittings',#10465,$,$); -#10484=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_25','Ductile iron pipes and fittings',#10465,$,$); -#10485=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_29','Flexible composite pipelines for liquid fuels',#10465,$,$); -#10486=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_30','Hot dip precoated carbon steel rainwater pipe and fittings',#10465,$,$); -#10487=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_31','Galvanized steel rainwater pipe and fittings',#10465,$,$); -#10488=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_32','Glass pipelines',#10465,$,$); -#10489=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_33','Glass reinforced plastics (GRP) pressure pipes and fittings',#10465,$,$); -#10490=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_34','Glass reinforced plastics (GRP) rainwater pipes and fittings',#10465,$,$); -#10491=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_35','Glass reinforced plastics (GRP) pipe and fittings for liquid fuels',#10465,$,$); -#10492=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_46','Lead pipes and fittings',#10465,$,$); -#10493=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_50','Medical gas copper tube',#10465,$,$); -#10494=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_52','Modified unplasticized polyvinyl chloride (MUPVC) pipes and fittings',#10465,$,$); -#10495=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_54','Multilayer pipelines for gaseous fuels',#10465,$,$); -#10496=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_55','Multilayer pipelines for water',#10465,$,$); -#10497=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_60','Polybutylene (PB) pipes and fittings',#10465,$,$); -#10498=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_61','Polyethylene (PE) drainage pipe and fittings',#10465,$,$); -#10499=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_62','Polyethylene (PE) gaseous fuel pipes and fittings',#10465,$,$); -#10500=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_63','Polyethylene (PE) water pipes and fittings',#10465,$,$); -#10501=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_64','Polyethylene (PE) pipes for liquid fuels',#10465,$,$); -#10502=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_65','Polypropylene (PP) pipelines',#10465,$,$); -#10503=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_66','Polypropylene (PP) solid wall pipes and fittings',#10465,$,$); -#10504=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_67','Polypropylene (PP) structured wall pipes and fittings',#10465,$,$); -#10505=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_68','Pre-insulated pipelines',#10465,$,$); -#10506=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_70','Propylene copolymer pressure pipes and fittings',#10465,$,$); -#10507=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_78','Stainless steel pipelines',#10465,$,$); -#10508=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_79','Stainless steel pipeline fittings',#10465,$,$); -#10509=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_80','Stainless steel rainwater pipes and fittings',#10465,$,$); -#10510=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_81','Stainless steel waste water pipes and fittings',#10465,$,$); -#10511=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_82','Steel pipelines',#10465,$,$); -#10512=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_83','Steel pipeline fittings',#10465,$,$); -#10513=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_84','Steel pipe and fittings for liquid fuels',#10465,$,$); -#10514=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_87','Unplasticized polyvinyl chloride (PVC-U) drainage pipe and fittings',#10465,$,$); -#10515=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_88','Unplasticized polyvinyl chloride (PVC-U) rainwater pipes and fittings',#10465,$,$); -#10516=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_89','Unplasticized polyvinyl chloride (PVC-U) pipelines',#10465,$,$); -#10517=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_90','Unplasticized polyvinyl chloride (PVC-U) solid wall pipes and fittings',#10465,$,$); -#10518=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_91','Unplasticized polyvinyl chloride (PVC-U) structured wall perforated pipes and fittings',#10465,$,$); -#10519=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_92','Unplasticized polyvinyl chloride (PVC-U) structured wall pipes and fittings',#10465,$,$); -#10520=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_93','Unplasticized polyvinyl chloride alloy (PVC-A) pipes and fittings',#10465,$,$); -#10521=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_94','Vitrified clay perforated pipes and fittings',#10465,$,$); -#10522=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_95','Vitrified clay plain wall open butt joint pipes and fittings',#10465,$,$); -#10523=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_96','Vitrified clay plain wall pipes and fittings',#10465,$,$); -#10524=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_99','Zinc rainwater pipes and fittings',#10465,$,$); -#10525=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53','Pump products',#10236,$,$); -#10526=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_24','Drainage pumps',#10525,$,$); -#10527=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_24_80','Small bore discharge macerator and pumps',#10526,$,$); -#10528=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_24_81','Small bore discharge pumps',#10526,$,$); -#10529=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_24_86','Submersible pumps',#10526,$,$); -#10530=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_65','Pump accessories',#10525,$,$); -#10531=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_65_04','Auto-coupling sets',#10530,$,$); -#10532=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86','Supply and exhaust pumps',#10525,$,$); -#10533=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_05','Automatic condensate pumps',#10532,$,$); -#10534=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_07','Belt driven end suction pumps',#10532,$,$); -#10535=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_11','Canned rotor pumps',#10532,$,$); -#10536=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_12','Centrifugal pumps',#10532,$,$); -#10537=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_13','Close-coupled end suction pumps',#10532,$,$); -#10538=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_15','Close-coupled in line pumps',#10532,$,$); -#10539=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_17','Condensate recovery units',#10532,$,$); -#10540=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_24','Dosing pump units',#10532,$,$); -#10541=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_32','Fuel oil transfer pumps',#10532,$,$); -#10542=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_33','Gas boosters',#10532,$,$); -#10543=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_50','Medical gas exhauster units',#10532,$,$); -#10544=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_51','Metering pumps',#10532,$,$); -#10545=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_55','Multi-stage pumps',#10532,$,$); -#10546=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_66','Pressure booster pumps',#10532,$,$); -#10547=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_68','Pressurization units',#10532,$,$); -#10548=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_86','Suction pumps',#10532,$,$); -#10549=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_94','Vapour pumps',#10532,$,$); -#10550=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96','Water supply and wastewater pumps',#10525,$,$); -#10551=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_02','Air lift pumps',#10550,$,$); -#10552=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_03','Archimedes screw pumps',#10550,$,$); -#10553=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_04','Axial flow pumps',#10550,$,$); -#10554=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_05','Axially split casing pumps',#10550,$,$); -#10555=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_06','Back pull-out end suction pumps',#10550,$,$); -#10556=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_21','Double diaphragm pumps',#10550,$,$); -#10557=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_23','Double disc pumps',#10550,$,$); -#10558=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_27','Electromagnetic pumps',#10550,$,$); -#10559=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_41','Inline multistage pumps',#10550,$,$); -#10560=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_44','Jet pumps',#10550,$,$); -#10561=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_50','Macerators',#10550,$,$); -#10562=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_51','Magnetic drive pumps',#10550,$,$); -#10563=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_55','Multistage centrifugal pumps',#10550,$,$); -#10564=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_63','Peristaltic pumps',#10550,$,$); -#10565=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_64','Positive displacement pumps',#10550,$,$); -#10566=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_65','Positive inlet pressure booster sets',#10550,$,$); -#10567=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_66','Progressing cavity pumps',#10550,$,$); -#10568=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_70','Ram pumps',#10550,$,$); -#10569=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_72','Rotary gear pumps',#10550,$,$); -#10570=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_73','Rotary lobe pumps',#10550,$,$); -#10571=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_74','Rotary vane pumps',#10550,$,$); -#10572=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_75','Screw pumps',#10550,$,$); -#10573=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_78','Single diaphragm pumps',#10550,$,$); -#10574=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_79','Single stage centrifugal pumps',#10550,$,$); -#10575=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_80','Solids handling pumps',#10550,$,$); -#10576=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_84','Submersible borehole pumps',#10550,$,$); -#10577=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_85','Submersible axial pumps',#10550,$,$); -#10578=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_86','Submersible centrifugal pumps',#10550,$,$); -#10579=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_87','Submersible mixed flow pumps',#10550,$,$); -#10580=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_94','Vertically suspended bowl type pumps',#10550,$,$); -#10581=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_95','Volute casing dry well centrifugal sewage and sludge pumps',#10550,$,$); -#10582=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54','Valve products',#10236,$,$); -#10583=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_24','Drainage valves',#10582,$,$); -#10584=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_24_02','Air admittance valves',#10583,$,$); -#10585=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_24_04','Anti-flood valves',#10583,$,$); -#10586=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30','Fire fighting valves and devices',#10582,$,$); -#10587=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_02','Alarm test valve assemblies',#10586,$,$); -#10588=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_09','Carbon dioxide connectors',#10586,$,$); -#10589=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_10','Caps and chains',#10586,$,$); -#10590=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_11','Carbon dioxide odorizing devices',#10586,$,$); -#10591=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_12','Check and non-return valves',#10586,$,$); -#10592=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_15','Container gas fire extinguishing valves',#10586,$,$); -#10593=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_22','Deluge valves',#10586,$,$); -#10594=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_23','Drain and test valves',#10586,$,$); -#10595=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_24','Dry riser landing valves',#10586,$,$); -#10596=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_25','Dry dropper outlet valves',#10586,$,$); -#10597=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_30','Fire fighting alarm devices',#10586,$,$); -#10598=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_32','Fusible links',#10586,$,$); -#10599=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_34','Gas fire suppression manifolds',#10586,$,$); -#10600=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_35','Gas fire suppression pressure gauges',#10586,$,$); -#10601=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_36','Gas fire suppression pressure switches',#10586,$,$); -#10602=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_37','High and low pressure selector gas fire extinguishing valves',#10586,$,$); -#10603=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_42','Inlet breechings',#10586,$,$); -#10604=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_50','Multiple control valves',#10586,$,$); -#10605=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_63','Pneumatic alarm devices',#10586,$,$); -#10606=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_85','Sprinkler system alarm valves',#10586,$,$); -#10607=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_95','Water fire extinguisher leather straps',#10586,$,$); -#10608=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_96','Water mist control valves',#10586,$,$); -#10609=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_97','Wet riser landing valves',#10586,$,$); -#10610=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33','Gas and liquid fuel valves',#10582,$,$); -#10611=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_03','Anti-siphon liquid fuel supply valves',#10610,$,$); -#10612=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_05','Automatic changeover liquid petroleum gas (LPG) valves',#10610,$,$); -#10613=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_10','Chlorine gas injectors',#10610,$,$); -#10614=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_11','Cast iron plug valves',#10610,$,$); -#10615=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_12','Chlorine gas manifolds',#10610,$,$); -#10616=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_13','Chlorine gas manifold pigtails',#10610,$,$); -#10617=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_14','Compressed air manifolds',#10610,$,$); -#10618=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_15','Compressed air pressure reducing stations',#10610,$,$); -#10619=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_17','Compressed air safety valves',#10610,$,$); -#10620=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_31','Fusible link drop weight valves',#10610,$,$); -#10621=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_33','Gas ball valves',#10610,$,$); -#10622=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_34','Gas burner safety devices',#10610,$,$); -#10623=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_35','Gas butterfly valves',#10610,$,$); -#10624=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_36','Gas pressure reducing stations',#10610,$,$); -#10625=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_37','Gas pressure switches',#10610,$,$); -#10626=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_38','Gas solenoid valves',#10610,$,$); -#10627=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_40','Gas vacuum regulators',#10610,$,$); -#10628=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_43','Industrial vacuum flow regulating valves',#10610,$,$); -#10629=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_44','Laboratory gas safety valves',#10610,$,$); -#10630=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_45','Laboratory gas taps',#10610,$,$); -#10631=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_46','Laboratory gas supply manifolds',#10610,$,$); -#10632=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_47','Liquefied petroleum gas (LPG) pressure regulators',#10610,$,$); -#10633=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_48','Liquefied petroleum gas (LPG) pressure relief valves',#10610,$,$); -#10634=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_49','Liquefied petroleum gas (LPG) shut off valves and emergency valves',#10610,$,$); -#10635=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_50','Mechanical gas safety valves',#10610,$,$); -#10636=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_51','Medical gas line valves',#10610,$,$); -#10637=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_52','Medical gas pressure reducing stations',#10610,$,$); -#10638=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_53','Medical gas service modules',#10610,$,$); -#10639=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_54','Medical gas supply manifolds',#10610,$,$); -#10640=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_55','Medical gas valve service units',#10610,$,$); -#10641=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_57','Medical vacuum flow regulating valves',#10610,$,$); -#10642=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_65','Pressure vacuum valves',#10610,$,$); -#10643=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_70','Refrigerant safety devices',#10610,$,$); -#10644=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_71','Remote acting fire safety liquid fuel supply valves',#10610,$,$); -#10645=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_74','Rupture discs',#10610,$,$); -#10646=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_76','Self-sealing liquid petroleum gas (LPG) couplers',#10610,$,$); -#10647=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_78','Shear valves',#10610,$,$); -#10648=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_84','Steel plug valves',#10610,$,$); -#10649=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_87','Taper plug valves',#10610,$,$); -#10650=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_93','Vacuum switches',#10610,$,$); -#10651=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_94','Vapour connection adaptors',#10610,$,$); -#10652=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_40','Irrigation valves',#10582,$,$); -#10653=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_40_02','Air valves',#10652,$,$); -#10654=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_40_13','Check valves',#10652,$,$); -#10655=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_40_16','Control valves',#10652,$,$); -#10656=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_40_44','Isolating valves',#10652,$,$); -#10657=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_40_62','Plastics isolating valves',#10652,$,$); -#10658=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_40_94','Volumetric control valves',#10652,$,$); -#10659=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_85','Steam valves',#10582,$,$); -#10660=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_85_06','Balanced pressure air vents',#10659,$,$); -#10661=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_85_07','Bellows sealed stop valves',#10659,$,$); -#10662=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_85_08','Blowdown valves',#10659,$,$); -#10663=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_85_22','Direct-acting pressure-reducing valves',#10659,$,$); -#10664=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_85_26','Electrically-actuated control steam valves',#10659,$,$); -#10665=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_85_60','Pilot-operated pressure-reducing valves',#10659,$,$); -#10666=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_85_62','Piston stop valves',#10659,$,$); -#10667=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_85_65','Pneumatically-actuated control steam valves',#10659,$,$); -#10668=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_85_77','Self-acting control steam valves',#10659,$,$); -#10669=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_85_78','Self-acting steam temperature valves',#10659,$,$); -#10670=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_85_79','Self-operating control valves',#10659,$,$); -#10671=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_85_88','Temperature and pressure control steam valves',#10659,$,$); -#10672=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_93','Valve accessories',#10582,$,$); -#10673=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_93_05','Automatic air vents',#10672,$,$); -#10674=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_93_06','Ball valve floats',#10672,$,$); -#10675=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_93_50','Manual air vents',#10672,$,$); -#10676=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_93_87','Test points',#10672,$,$); -#10677=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_93_88','T-keys',#10672,$,$); -#10678=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_93_94','Valve keys',#10672,$,$); -#10679=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94','Water supply valves',#10582,$,$); -#10680=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_03','Anti-pollution check valves',#10679,$,$); -#10681=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_11','Cast iron wedge gate valves',#10679,$,$); -#10682=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_22','Direct acting float actuated automatic control valves',#10679,$,$); -#10683=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_23','Direct spring operated pressure relief valves',#10679,$,$); -#10684=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_24','Double orifice air valves',#10679,$,$); -#10685=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_26','Eccentric plug valves',#10679,$,$); -#10686=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_29','Flap valves',#10679,$,$); -#10687=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_30','Flexible rubber check valves',#10679,$,$); -#10688=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_31','Free discharge valves',#10679,$,$); -#10689=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_39','Hydrostatic bellmouth valves',#10679,$,$); -#10690=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_45','Knife gate valves',#10679,$,$); -#10691=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_47','Line pressure driven automatic control valves',#10679,$,$); -#10692=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_50','Metallic butterfly valves',#10679,$,$); -#10693=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_55','Needle valves',#10679,$,$); -#10694=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_56','Non-slam nozzle check valves',#10679,$,$); -#10695=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_57','Non-slam twin plate check valves',#10679,$,$); -#10696=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_60','Pallet type pressure relief valves',#10679,$,$); -#10697=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_62','Pilot operated valves',#10679,$,$); -#10698=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_63','Pinch type pressure relief valves',#10679,$,$); -#10699=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_65','Plunger valves',#10679,$,$); -#10700=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_70','Recoil resilient hinge disc check valves',#10679,$,$); -#10701=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_71','Recoil swing disc check valves',#10679,$,$); -#10702=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_72','Reduced pressure zone valves',#10679,$,$); -#10703=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_73','Resilient hinge disc check valves',#10679,$,$); -#10704=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_77','Single large orifice air valves',#10679,$,$); -#10705=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_78','Single small orifice air valves',#10679,$,$); -#10706=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_87','Solenoid operated valves',#10679,$,$); -#10707=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_90','Triple orifice air valves',#10679,$,$); -#10708=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_94','Vacuum breaker air valves',#10679,$,$); -#10709=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_95','V-port ball valves',#10679,$,$); -#10710=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95','Water services valves',#10582,$,$); -#10711=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_05','Backflow prevention check valves',#10710,$,$); -#10712=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_06','Ball valves',#10710,$,$); -#10713=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_08','Butterfly valves',#10710,$,$); -#10714=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_11','Cast iron check valves',#10710,$,$); -#10715=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_12','Cast iron gate valves',#10710,$,$); -#10716=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_13','Cast iron globe valves',#10710,$,$); -#10717=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_14','Copper alloy check valves',#10710,$,$); -#10718=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_15','Copper alloy gate valves',#10710,$,$); -#10719=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_16','Copper alloy globe valves',#10710,$,$); -#10720=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_18','Copper alloy service stop valves',#10710,$,$); -#10721=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_19','Copper alloy stop valves',#10710,$,$); -#10722=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_20','Copper alloy underground stop valves',#10710,$,$); -#10723=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_21','Commissioning manifolds',#10710,$,$); -#10724=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_23','Draw off taps',#10710,$,$); -#10725=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_24','Diaphragm valves',#10710,$,$); -#10726=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_25','Differential pressure control valves',#10710,$,$); -#10727=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_26','Double regulating valves',#10710,$,$); -#10728=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_27','Draining taps',#10710,$,$); -#10729=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_28','Excess pressure valves',#10710,$,$); -#10730=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_29','Float-operated valves',#10710,$,$); -#10731=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_30','Flow measuring valves',#10710,$,$); -#10732=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_31','Flow-reducing servicing valves',#10710,$,$); -#10733=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_33','Foot valves',#10710,$,$); -#10734=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_38','Hose union backflow prevention devices',#10710,$,$); -#10735=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_42','In-line anti-vacuum backflow prevention devices',#10710,$,$); -#10736=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_47','Low pressure thermostatic mixing valves',#10710,$,$); -#10737=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_48','Low temperature thermostatic mixing valves',#10710,$,$); -#10738=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_50','Metering valves',#10710,$,$); -#10739=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_53','Motorized valves',#10710,$,$); -#10740=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_63','Pressure independent control valves',#10710,$,$); -#10741=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_64','Pressure regulating valves',#10710,$,$); -#10742=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_65','Pressure relief valves',#10710,$,$); -#10743=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_66','Pressure reducing valves',#10710,$,$); -#10744=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_67','Pressure surplussing valves',#10710,$,$); -#10745=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_70','Radiator valves',#10710,$,$); -#10746=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_75','Safety valves',#10710,$,$); -#10747=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_80','Steel alloy check valves',#10710,$,$); -#10748=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_81','Steel ball valves',#10710,$,$); -#10749=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_82','Steel globe valves',#10710,$,$); -#10750=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_83','Steel globe stop and check valves',#10710,$,$); -#10751=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_86','Thermostatic balancing valves',#10710,$,$); -#10752=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_87','Tempering valves',#10710,$,$); -#10753=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_88','Thermostatic mixing valves',#10710,$,$); -#10754=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_89','Thermostatic radiator valves',#10710,$,$); -#10755=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_90','Three-way vent cocks',#10710,$,$); -#10756=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_92','Underfloor heating and cooling manifolds',#10710,$,$); -#10757=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_94','Verifiable backflow prevention devices',#10710,$,$); -#10758=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_96','Waterworks gate valves',#10710,$,$); -#10759=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55','Liquid and gas distribution products',#10236,$,$); -#10760=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_62','Phase change distribution products',#10759,$,$); -#10761=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_62_12','Chlorine catchpots',#10760,$,$); -#10762=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_62_47','Liquefied petroleum gas (LPG) vaporizers',#10760,$,$); -#10763=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_76','Separators',#10759,$,$); -#10764=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_76_04','Austenitic stainless steel steam separators',#10763,$,$); -#10765=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_76_11','Carbon steel steam separators',#10763,$,$); -#10766=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_76_12','Cast iron steam separators',#10763,$,$); -#10767=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_76_13','Centrifugal air separators',#10763,$,$); -#10768=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_76_15','Combined air and dirt separators',#10763,$,$); -#10769=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_76_22','Dirt separators',#10763,$,$); -#10770=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_76_58','Oil and petrol separators',#10763,$,$); -#10771=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_76_59','Oil and water separators',#10763,$,$); -#10772=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_76_77','SG iron steam separators',#10763,$,$); -#10773=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_76_84','Stainless steel steam separators',#10763,$,$); -#10774=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_76_96','Water separators',#10763,$,$); -#10775=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_84','Steam and condensate distribution products',#10759,$,$); -#10776=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_84_50','Steam manifolds',#10775,$,$); -#10777=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_84_75','Sample coolers',#10775,$,$); -#10778=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_84_94','Vacuum breakers',#10775,$,$); -#10779=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_85','Steam and condensate recovery vessels',#10759,$,$); -#10780=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_85_08','Blowdown vessels',#10779,$,$); -#10781=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_85_30','Flash steam recovery vessels',#10779,$,$); -#10782=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_85_85','Steam feedtanks',#10779,$,$); -#10783=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_86','Steam traps and strainers',#10759,$,$); -#10784=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_86_05','Angle steam strainers',#10783,$,$); -#10785=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_86_06','Balanced pressure steam traps',#10783,$,$); -#10786=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_86_07','Ball float steam traps',#10783,$,$); -#10787=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_86_08','Bimetallic steam traps',#10783,$,$); -#10788=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_86_42','Inverted bucket steam traps',#10783,$,$); -#10789=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_86_88','Thermodynamic steam traps',#10783,$,$); -#10790=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_86_89','Thermostatic steam traps',#10783,$,$); -#10791=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_86_99','Y-type steam strainers',#10783,$,$); -#10792=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_96','Washing products',#10759,$,$); -#10793=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_96_24','Drive-through wheel wash',#10792,$,$); -#10794=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_96_72','Roller wheel wash',#10792,$,$); -#10795=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_96_96','Wash plant',#10792,$,$); -#10796=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57','Filter products',#10236,$,$); -#10797=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02','Air filters',#10796,$,$); -#10798=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_02','Activated carbon air filters',#10797,$,$); -#10799=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_03','Air gas and vapour cleaners',#10797,$,$); -#10800=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_04','Air particle cleaners',#10797,$,$); -#10801=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_06','Baffle grease air filters',#10797,$,$); -#10802=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_07','Bag air filters',#10797,$,$); -#10803=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_11','Cartridge grease air filters',#10797,$,$); -#10804=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_15','Cold water mist grease air filters',#10797,$,$); -#10805=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_20','Cyclone filters',#10797,$,$); -#10806=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_25','Duct-mounted modular electrostatic air filters',#10797,$,$); -#10807=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_26','Efficient particulate arrestor (EPA) air filters',#10797,$,$); -#10808=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_28','Electrostatic precipitators',#10797,$,$); -#10809=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_29','Fabric filters',#10797,$,$); -#10810=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_37','High efficiency particle arrestor (HEPA) air filters',#10797,$,$); -#10811=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_52','Mesh air filters',#10797,$,$); -#10812=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_66','Panel air filters',#10797,$,$); -#10813=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_70','Safe change filter changing units',#10797,$,$); -#10814=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_92','Ultra low particle arrestor (ULPA) air filters',#10797,$,$); -#10815=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_93','Ultraviolet light grease filters',#10797,$,$); -#10816=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_96','Water wash grease air filters',#10797,$,$); -#10817=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_97','Wet scrubber filters',#10797,$,$); -#10818=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_33','Gas and air filters',#10796,$,$); -#10819=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_33_02','Activated carbon compressed air filters',#10818,$,$); -#10820=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_33_15','Coalescing compressed air filters',#10818,$,$); -#10821=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_33_25','Dust compressed air filters',#10818,$,$); -#10822=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_33_33','Gas filters',#10818,$,$); -#10823=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_58','Oil filters and strainers',#10796,$,$); -#10824=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_58_58','Oil filters',#10823,$,$); -#10825=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_58_59','Oil strainers',#10823,$,$); -#10826=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_85','Swimming pool water filters and strainers',#10796,$,$); -#10827=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_85_06','Basket filters',#10826,$,$); -#10828=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_85_07','Basket strainers',#10826,$,$); -#10829=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_85_12','Cartridge pool water filters',#10826,$,$); -#10830=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_85_22','Diatomaceous earth water filters',#10826,$,$); -#10831=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_85_33','Glass media water filters',#10826,$,$); -#10832=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_85_65','Pressure water filters',#10826,$,$); -#10833=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_85_70','Regenerative water filters',#10826,$,$); -#10834=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_85_75','Sand water filters',#10826,$,$); -#10835=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_95','Water feature filters and strainers',#10796,$,$); -#10836=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_95_07','Biological filters',#10835,$,$); -#10837=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_95_11','Cartridge water filters',#10835,$,$); -#10838=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_95_13','Centrifugal particle separators',#10835,$,$); -#10839=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_95_22','Disc filters',#10835,$,$); -#10840=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_95_42','Inline water filters',#10835,$,$); -#10841=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_95_51','Media water filters',#10835,$,$); -#10842=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_95_76','Screen filters',#10835,$,$); -#10843=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_95_96','Water strainers',#10835,$,$); -#10844=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96','Water filters and strainers',#10796,$,$); -#10845=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_02','Activated carbon water filters',#10844,$,$); -#10846=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_03','Active biological water filters',#10844,$,$); -#10847=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_04','Angle water strainers',#10844,$,$); -#10848=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_08','Basket water strainers',#10844,$,$); -#10849=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_09','Bottle brush water filters',#10844,$,$); -#10850=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_11','Canister water filters',#10844,$,$); -#10851=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_13','Chlorine dioxide biological water filters',#10844,$,$); -#10852=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_16','Conical water filters',#10844,$,$); -#10853=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_29','Fast bed rapid sand water filters',#10844,$,$); -#10854=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_30','Floating tank water filters',#10844,$,$); -#10855=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_34','Granular activated carbon water filters',#10844,$,$); -#10856=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_35','Gravel water filters',#10844,$,$); -#10857=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_52','Membrane water filters',#10844,$,$); -#10858=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_53','Mesh water filters',#10844,$,$); -#10859=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_62','Pilot water filters',#10844,$,$); -#10860=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_70','Rapid gravity water filters',#10844,$,$); -#10861=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_72','Reed bed water filters',#10844,$,$); -#10862=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_77','Side stream water filters',#10844,$,$); -#10863=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_79','Slow bed sand water filters',#10844,$,$); -#10864=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_86','Subsurface vortex water filters',#10844,$,$); -#10865=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_99','Y-type water strainers',#10844,$,$); -#10866=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65','Ductwork products',#10236,$,$); -#10867=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_23','Ductwork accessories',#10866,$,$); -#10868=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_23_20','Duct access panels',#10867,$,$); -#10869=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_23_25','Ductwork access doorsets',#10867,$,$); -#10870=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_24','Duct dampers',#10866,$,$); -#10871=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_24_16','Constant volume boxes',#10870,$,$); -#10872=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_24_29','Fire and smoke dampers',#10870,$,$); -#10873=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_24_30','Fire dampers',#10870,$,$); -#10874=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_24_42','Intumescent fire and smoke dampers',#10870,$,$); -#10875=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_24_56','Non-return dampers',#10870,$,$); -#10876=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_24_66','Pressure control flaps',#10870,$,$); -#10877=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_24_68','Pressure relief dampers',#10870,$,$); -#10878=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_24_78','Shut off dampers',#10870,$,$); -#10879=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_24_80','Smoke dampers',#10870,$,$); -#10880=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_24_93','Variable air volume boxes',#10870,$,$); -#10881=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_24_95','Volume control dampers',#10870,$,$); -#10882=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_25','Ductwork and fittings',#10866,$,$); -#10883=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_25_13','Circular plastics ductwork and fittings',#10882,$,$); -#10884=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_25_14','Circular sheet metal ductwork and fittings',#10882,$,$); -#10885=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_25_23','Domestic rigid ductwork and fittings',#10882,$,$); -#10886=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_25_28','Fabric ductwork and fittings',#10882,$,$); -#10887=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_25_30','Fire resisting ductwork and fittings',#10882,$,$); -#10888=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_25_31','Flat oval sheet metal ductwork and fittings',#10882,$,$); -#10889=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_25_32','Flexible ductwork',#10882,$,$); -#10890=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_25_34','Glass fibre ductwork and fittings',#10882,$,$); -#10891=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_25_64','Pre-insulated ductwork and fittings',#10882,$,$); -#10892=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_25_71','Rectangular plastics ductwork and fittings',#10882,$,$); -#10893=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_25_72','Rectangular sheet metal ductwork and fittings',#10882,$,$); -#10894=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_25_77','Smoke extract ductwork',#10882,$,$); -#10895=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67','Air and fume distribution products',#10236,$,$); -#10896=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_16','Compressed air products',#10895,$,$); -#10897=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_16_02','Air compressors',#10896,$,$); -#10898=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_16_03','Air-cooled aftercoolers',#10896,$,$); -#10899=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_16_04','Air preparation units',#10896,$,$); -#10900=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_16_05','Air receivers',#10896,$,$); -#10901=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_16_08','Blow protectors',#10896,$,$); -#10902=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_16_22','Desiccant air dryers',#10896,$,$); -#10903=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_16_50','Medical gas compressors',#10896,$,$); -#10904=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_16_71','Refrigerant air dryers',#10896,$,$); -#10905=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_16_96','Water-cooled aftercoolers',#10896,$,$); -#10906=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_22','De-aerators',#10895,$,$); -#10907=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_22_47','Liquid fuel de-aerators',#10906,$,$); -#10908=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_22_66','Pressure differential de-aerators',#10906,$,$); -#10909=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_22_88','Temperature differential de-aerators',#10906,$,$); -#10910=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_28','Expansion compensators',#10895,$,$); -#10911=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_28_03','Angular expansion compensators',#10910,$,$); -#10912=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_28_05','Axial expansion compensators',#10910,$,$); -#10913=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_28_46','Lateral expansion compensators',#10910,$,$); -#10914=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29','Fans',#10895,$,$); -#10915=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_05','Axial flow fans',#10914,$,$); -#10916=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_09','Bifurcated fans',#10914,$,$); -#10917=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_12','Centrifugal fans',#10914,$,$); -#10918=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_23','Domestic fan units',#10914,$,$); -#10919=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_24','Domestic multipoint fan units',#10914,$,$); -#10920=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_44','Jet fans',#10914,$,$); -#10921=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_52','Mixed flow fans',#10914,$,$); -#10922=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_62','Plug fans',#10914,$,$); -#10923=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_64','Powered smoke and heat exhaust ventilators',#10914,$,$); -#10924=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_67','Propeller fans',#10914,$,$); -#10925=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_72','Roof mounted fans',#10914,$,$); -#10926=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_80','Smoke extract fans',#10914,$,$); -#10927=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_88','Twin axial fans',#10914,$,$); -#10928=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_89','Twin centrifugal fans',#10914,$,$); -#10929=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_96','Whole dwelling fan units',#10914,$,$); -#10930=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_39','Humidifiers and dehumidifiers',#10895,$,$); -#10931=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_39_22','Desiccant dehumidifiers',#10930,$,$); -#10932=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_39_28','Evaporative humidifiers',#10930,$,$); -#10933=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_39_37','Heat pump dehumidifiers',#10930,$,$); -#10934=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_39_84','Steam humidifiers',#10930,$,$); -#10935=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_39_96','Water atomizing humidifiers',#10930,$,$); -#10936=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_46','Laboratory gas products',#10895,$,$); -#10937=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_46_56','Nitrogen receivers',#10936,$,$); -#10938=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_78','Sound attenuators',#10895,$,$); -#10939=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_78_02','Acoustic duct linings',#10938,$,$); -#10940=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_78_05','Air transfer and cross talk attenuators',#10938,$,$); -#10941=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_78_07','Attenuated openings',#10938,$,$); -#10942=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_78_12','Circular attenuators',#10938,$,$); -#10943=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_78_72','Rectangular attenuators',#10938,$,$); -#10944=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_94','Vehicle exhaust distribution products',#10895,$,$); -#10945=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_94_25','Ducted rail tracks',#10944,$,$); -#10946=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_94_76','Self-sealing floor plates',#10944,$,$); -#10947=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70','Cables, conductors and fittings products',#10236,$,$); -#10948=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11','Cable management and accessories',#10947,$,$); -#10949=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_02','Cable assemblies',#10948,$,$); -#10950=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_09','Buried conduit',#10948,$,$); -#10951=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_10','Cable brackets',#10948,$,$); -#10952=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_11','Cable bands',#10948,$,$); -#10953=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_12','Cable baskets',#10948,$,$); -#10954=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_13','Cable cleats',#10948,$,$); -#10955=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_14','Cable ladders',#10948,$,$); -#10956=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_15','Cable ties',#10948,$,$); -#10957=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_16','Cable troughs',#10948,$,$); -#10958=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_17','Cable trays',#10948,$,$); -#10959=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_18','Cable trunking',#10948,$,$); -#10960=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_19','Channel cable supports',#10948,$,$); -#10961=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_20','Conduit fittings',#10948,$,$); -#10962=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_25','Duct banks',#10948,$,$); -#10963=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_29','Flexible electrical cable carriers',#10948,$,$); -#10964=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_30','Flexible conduit',#10948,$,$); -#10965=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_31','Floor cable trunking and ducting',#10948,$,$); -#10966=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_34','Cable glands',#10948,$,$); -#10967=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_41','Insulating cable trays',#10948,$,$); -#10968=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_47','Lighting busbar trunking',#10948,$,$); -#10969=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_61','Perimeter trunking',#10948,$,$); -#10970=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_62','Plastic ducts for buried electric cables',#10948,$,$); -#10971=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_63','Pliable conduit',#10948,$,$); -#10972=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_64','Points heating harnesses',#10948,$,$); -#10973=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_65','Polyvinyl chloride (PVC) trunking',#10948,$,$); -#10974=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_70','Raised access floor service outlets',#10948,$,$); -#10975=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_71','Rigid conduit',#10948,$,$); -#10976=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_75','Service outlet boxes',#10948,$,$); -#10977=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_76','Service outlet poles',#10948,$,$); -#10978=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_79','Slotted cable trunking',#10948,$,$); -#10979=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_80','Slotted insulating cable trays',#10948,$,$); -#10980=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_12','Cable protection products',#10947,$,$); -#10981=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_12_04','Anti-vandal cable guards',#10980,$,$); -#10982=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_12_11','Cable capping',#10980,$,$); -#10983=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_12_92','Underground concrete cable protection covers',#10980,$,$); -#10984=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_12_94','Underground plastics cable protection covers',#10980,$,$); -#10985=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_13','Cathodic protection products',#10947,$,$); -#10986=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_13_08','Bulk anodes',#10985,$,$); -#10987=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_13_50','Mesh anodes',#10985,$,$); -#10988=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_13_72','Rod anodes',#10985,$,$); -#10989=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_13_85','Sheet anodes',#10985,$,$); -#10990=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15','Communications cables and accessories',#10947,$,$); -#10991=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_03','Armoured coaxial communications cables',#10990,$,$); -#10992=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_04','Armoured communications cables',#10990,$,$); -#10993=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_06','Balanced twisted-pair cables',#10990,$,$); -#10994=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_13','Coaxial cables',#10990,$,$); -#10995=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_15','Copper cable connectors',#10990,$,$); -#10996=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_16','Copper cable terminations',#10990,$,$); -#10997=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_17','Copper voice cables',#10990,$,$); -#10998=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_18','Copper voice (LSF) cables',#10990,$,$); -#10999=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_32','Functional earth cables',#10990,$,$); -#11000=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_50','Microphone cables',#10990,$,$); -#11001=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_53','Multicore alarm cables',#10990,$,$); -#11002=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_58','Optical fibre cables',#10990,$,$); -#11003=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_59','Optical fibre cable connectors',#10990,$,$); -#11004=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_60','Optical fibre patch cords',#10990,$,$); -#11005=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_62','Optical fibre splice boxes',#10990,$,$); -#11006=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_63','Optical fibre cable terminations',#10990,$,$); -#11007=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_70','Radio frequency (RF) transmission cables',#10990,$,$); -#11008=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_80','Speaker cables',#10990,$,$); -#11009=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_96','Work area and patch cord cables',#10990,$,$); -#11010=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_16','Conductor rail ancillaries',#10947,$,$); -#11011=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_16_03','Anchor struts',#11010,$,$); -#11012=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_16_08','Composite insulators',#11010,$,$); -#11013=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_16_10','Conductor rail anchors',#11010,$,$); -#11014=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_16_12','Conductor rail cover boards',#11010,$,$); -#11015=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_16_15','Conductor rail guard boards',#11010,$,$); -#11016=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_16_16','Conductor rail insulators',#11010,$,$); -#11017=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_16_17','Conductor rail side ramps',#11010,$,$); -#11018=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_16_20','Conductor rail supports',#11010,$,$); -#11019=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_16_28','Eutectic strips',#11010,$,$); -#11020=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_16_34','Glass reinforced nylon insulators',#11010,$,$); -#11021=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_16_57','Nylon insulators',#11010,$,$); -#11022=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_36','High voltage cables',#10947,$,$); -#11023=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_36_34','High voltage cold shrink cable joints',#11022,$,$); -#11024=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_36_35','High voltage extruded insulation cable terminations',#11022,$,$); -#11025=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_36_36','High voltage paper insulated cable terminations',#11022,$,$); -#11026=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_36_37','High voltage power cables with extruded insulation',#11022,$,$); -#11027=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_36_38','High voltage power cables with low smoke thermosetting insulation',#11022,$,$); -#11028=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_36_39','High voltage power cables with impregnated paper insulation lead alloy sheath',#11022,$,$); -#11029=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_36_40','High voltage power cables with thermosetting insulation',#11022,$,$); -#11030=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_42','Insulators',#10947,$,$); -#11031=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_42_26','Deadend insulators',#11030,$,$); -#11032=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_42_36','High voltage pin insulators',#11030,$,$); -#11033=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_42_46','Line post insulators',#11030,$,$); -#11034=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_42_47','Longrod insulators',#11030,$,$); -#11035=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_42_48','Low voltage pin insulators',#11030,$,$); -#11036=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_42_77','Shackle insulators',#11030,$,$); -#11037=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_42_82','Spool insulators',#11030,$,$); -#11038=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_42_83','Station post insulators',#11030,$,$); -#11039=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_42_84','Stay insulators',#11030,$,$); -#11040=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_42_85','Strain insulators',#11030,$,$); -#11041=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_42_86','Suspension insulators',#11030,$,$); -#11042=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46','Lightning protection and earthing components',#10947,$,$); -#11043=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_01','Air terminals',#11042,$,$); -#11044=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_03','Aluminium earth tapes',#11042,$,$); -#11045=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_04','Aluminium rod lightning conductors',#11042,$,$); -#11046=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_14','Copper earth tapes',#11042,$,$); -#11047=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_15','Copper solid circular lightning conductors',#11042,$,$); -#11048=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_24','Earth bars',#11042,$,$); -#11049=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_25','Earth plates',#11042,$,$); -#11050=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_26','Earth rod inspection pits',#11042,$,$); -#11051=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_27','Earth rods',#11042,$,$); -#11052=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_29','Earthing clamps',#11042,$,$); -#11053=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_30','Earthing conductors',#11042,$,$); -#11054=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_32','Flexible braids',#11042,$,$); -#11055=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_46','Lightning protection conductor clamps',#11042,$,$); -#11056=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_47','Lightning protection conductor metallic direct contact clips',#11042,$,$); -#11057=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_48','Lightning protection conductor non-metallic direct contact clips',#11042,$,$); -#11058=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_80','Soil conditioning conductive agents',#11042,$,$); -#11059=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48','Low voltage cables',#10947,$,$); -#11060=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_13','Crosslinked EVA insulated single core non-sheathed cables',#11059,$,$); -#11061=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_14','Crosslinked silicone rubber insulated single core cables',#11059,$,$); -#11062=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_29','Fire resistant screened (LSHF) cables',#11059,$,$); -#11063=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_31','Flexible cables with crosslinked elastomeric insulation',#11059,$,$); -#11064=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_32','Flexible cables with thermoplastic PVC insulation',#11059,$,$); -#11065=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_37','Heat resistant single-core non-sheathed cross-linked elastomeric insulated cables',#11059,$,$); -#11066=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_38','Heavy-duty cross-linked elastomeric insulated and sheathed flexible cables',#11059,$,$); -#11067=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_39','Heavy-duty heat resistant cross-linked elastomeric insulated and sheathed flexible cables',#11059,$,$); -#11068=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_40','Heavy-duty heat resistant LSHF insulated and sheathed flexible cables',#11059,$,$); -#11069=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_41','Heavy-duty mineral insulated cables',#11059,$,$); -#11070=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_46','Light duty heat resistant PVC insulated and sheathed flexible cables',#11059,$,$); -#11071=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_48','Light duty mineral insulated cables',#11059,$,$); -#11072=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_49','Light duty PVC insulated and sheathed flexible cables',#11059,$,$); -#11073=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_50','Low voltage cold shrink cable joints',#11059,$,$); -#11074=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_51','Mineral insulation cables',#11059,$,$); -#11075=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_55','Multicore screened thermosetting insulated (LSHF) sheathed cables',#11059,$,$); -#11076=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_56','Ordinary duty cross-linked elastomeric insulated and sheathed flexible cables',#11059,$,$); -#11077=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_57','Ordinary duty heat resistant cross-linked elastomeric insulated and sheathed flexible cables',#11059,$,$); -#11078=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_58','Ordinary duty heat resistant PVC insulated and sheathed flexible cables',#11059,$,$); -#11079=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_59','Ordinary duty low temperature PVC insulated and sheathed flexible cables',#11059,$,$); -#11080=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_60','Ordinary duty PVC insulated and sheathed flexible cables',#11059,$,$); -#11081=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_61','PVC insulated and sheathed cables',#11059,$,$); -#11082=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_62','PVC insulated flexible single core cables for switchgear and controlgear wiring',#11059,$,$); -#11083=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_63','PVC insulated single core non-sheathed cables',#11059,$,$); -#11084=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_73','Single core heavy-duty cross-linked insulated and sheathed flexible (LSHF) cables',#11059,$,$); -#11085=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_74','Single core heat resistant non-sheathed thermoplastic PVC insulated cables',#11059,$,$); -#11086=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_75','Single core non-sheathed (LHSF) insulated cables',#11059,$,$); -#11087=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_77','Single core PVC insulated cables',#11059,$,$); -#11088=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_79','Split concentric PVC insulated and sheathed cables',#11059,$,$); -#11089=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_88','Thermosetting insulated armoured fire resistant (LSHF) cables',#11059,$,$); -#11090=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_89','Thermosetting insulated and PVC sheathed armoured cables',#11059,$,$); -#11091=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_90','Thermosetting insulated and thermoplastic sheathed (LSHF) armoured cables',#11059,$,$); -#11092=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_91','Thermosetting insulated and thermoplastic sheathed (LSHF) cables',#11059,$,$); -#11093=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_92','Thermosetting insulated non armoured PVC sheathed cables',#11059,$,$); -#11094=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_93','Thermosetting insulated (XLPE), thermoplastic low smoke zero halogen (LSZH) sheathed cables',#11059,$,$); -#11095=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_94','Thermosetting insulated, non-armoured, fire-resistant, single core non-sheathed cables',#11059,$,$); -#11096=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_95','Thermosetting insulated single core fire resistant non-armoured non-sheathed cables',#11059,$,$); -#11097=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_50','Low voltage prefabricated cables',#10947,$,$); -#11098=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_50_15','Connection cables',#11097,$,$); -#11099=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_50_22','Distribution connectors',#11097,$,$); -#11100=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_50_28','Extender cables',#11097,$,$); -#11101=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_50_37','Home run cables',#11097,$,$); -#11102=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_50_47','Lighting extender leads',#11097,$,$); -#11103=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_50_49','Luminaire connection cables',#11097,$,$); -#11104=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_50_64','Prefabricated low smoke zero halogen (LSZH) insulated and sheathed multi-core cables',#11097,$,$); -#11105=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_50_66','Prefabricated low smoke zero halogen (LSZH) insulated single cables in flexible conduit',#11097,$,$); -#11106=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_50_72','RJ45 cables',#11097,$,$); -#11107=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_50_84','Starter leads',#11097,$,$); -#11108=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_50_86','Switch connection leads',#11097,$,$); -#11109=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_50_88','T connectors',#11097,$,$); -#11110=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_70','Railway rolling stock cables',#10947,$,$); -#11111=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_70_53','Multicore, cross-linked elastomeric-insulated, reduced dimensions, special fire performance cables',#11110,$,$); -#11112=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_70_55','Multicore, cross-linked elastomeric-insulated, special fire performance cables',#11110,$,$); -#11113=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_70_57','Multicore and multi-pair, thin wall-insulated, special fire performance cables',#11110,$,$); -#11114=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_70_83','Screened, multicore, cross-linked elastomeric-insulated, reduced dimensions, special fire performance cables',#11110,$,$); -#11115=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_70_85','Single core, cross-linked elastomeric-insulated, reduced dimensions, special fire performance cables',#11110,$,$); -#11116=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_70_87','Single core, cross-linked elastomeric-insulated, 600/1000 V, special fire performance cables',#11110,$,$); -#11117=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_70_88','Single core, cross-linked elastomeric-insulated, 1.8/3 kV, special fire performance cables',#11110,$,$); -#11118=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_70_89','Single core, silicone rubber-insulated, high-temperature, special fire performance cables',#11110,$,$); -#11119=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_70_91','Single core, thin wall-insulated, special fire performance cables',#11110,$,$); -#11120=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80','Signalling cables',#10947,$,$); -#11121=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_01','2 core unscreened 1000 V (LSF) cables',#11120,$,$); -#11122=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_03','Abrasion resistant single core triple insulated (LSF) signalling equipment room cables',#11120,$,$); -#11123=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_14','Concentric screened cables with screens separate',#11120,$,$); -#11124=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_16','Concentric screened (LSF) cables with screens separate',#11120,$,$); -#11125=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_46','Multicore concentric screened (LSF) track crossing cables with screens in contact',#11120,$,$); -#11126=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_47','Multicore concentric screened track crossing cables with screens in contact',#11120,$,$); -#11127=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_49','Multicore concentric screened track crossing cables with screens separate',#11120,$,$); -#11128=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_51','Multicore screened (LSF) cable run cables',#11120,$,$); -#11129=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_52','Multicore screened (LSF) track crossing cables',#11120,$,$); -#11130=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_53','Multicore screened pair (LSF) axle counter cables',#11120,$,$); -#11131=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_55','Multi-pair screened (LSF) cables with each pair screened',#11120,$,$); -#11132=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_74','Single core double insulated inductive loop track cables',#11120,$,$); -#11133=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_75','Single core double insulated (LSF) 600 V cables',#11120,$,$); -#11134=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_76','Single core double insulated (LSF) 600 V track crossing cables',#11120,$,$); -#11135=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_78','Single core double insulated (LSF) signalling equipment room cables',#11120,$,$); -#11136=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_79','Single core double insulated (LSF) track crossing cables',#11120,$,$); -#11137=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_81','Single core (LSF) cables',#11120,$,$); -#11138=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_83','Single core screened pair axle counter cables',#11120,$,$); -#11139=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_87','Triaxial concentric cables',#11120,$,$); -#11140=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_88','Triaxial concentric (LSF) cables',#11120,$,$); -#11141=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_90','Twisted pair screened (LSF) cable run cables',#11120,$,$); -#11142=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_91','Twisted pair screened (LSF) signalling equipment room cables',#11120,$,$); -#11143=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_92','Twisted pair screened (LSF) track crossing cables',#11120,$,$); -#11144=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72','Electrical power products and wiring accessories',#10236,$,$); -#11145=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27','Electrical protective devices',#11144,$,$); -#11146=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_02','Air circuit breakers',#11145,$,$); -#11147=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_11','Cartridge fuses',#11145,$,$); -#11148=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_23','Direct current (d.c.) surge protection devices',#11145,$,$); -#11149=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_26','Earth continuity monitors',#11145,$,$); -#11150=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_32','Fuse links',#11145,$,$); -#11151=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_34','Fuse lock-off devices',#11145,$,$); -#11152=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_42','Isolation transformers',#11145,$,$); -#11153=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_44','J-type feeder pillar fuses',#11145,$,$); -#11154=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_47','Low-voltage fuse links',#11145,$,$); -#11155=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_48','Low voltage power supply surge protection devices',#11145,$,$); -#11156=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_50','Mains power supply transient overvoltage suppression devices',#11145,$,$); -#11157=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_52','Miniature circuit breakers',#11145,$,$); -#11158=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_53','Moulded case circuit breakers',#11145,$,$); -#11159=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_72','Residual current circuit breakers',#11145,$,$); -#11160=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_73','Residual current circuit breakers with integral overcurrent protection',#11145,$,$); -#11161=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_74','Residual current monitors',#11145,$,$); -#11162=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_88','Transient overvoltage surge suppression devices',#11145,$,$); -#11163=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_43','Power conditioning equipment',#11144,$,$); -#11164=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_43_01','Active electrical filters',#11163,$,$); -#11165=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_43_05','Automatic power factor correction equipment',#11163,$,$); -#11166=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_43_07','Blocking diodes',#11163,$,$); -#11167=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_43_39','Hybrid electrical filters',#11163,$,$); -#11168=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_43_42','Inverters',#11163,$,$); -#11169=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_43_60','Passive electrical filters',#11163,$,$); -#11170=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_43_64','Power conditioning units',#11163,$,$); -#11171=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_43_71','Rectifiers',#11163,$,$); -#11172=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_43_95','Voltage optimizers',#11163,$,$); -#11173=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_43_96','Voltage transformers',#11163,$,$); -#11174=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_59','Overhead power supply line products',#11144,$,$); -#11175=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_59_06','Balance weight anchor tensioning devices',#11174,$,$); -#11176=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_59_80','Spring tensioning devices',#11174,$,$); -#11177=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_59_90','Turnbuckle tensioning devices',#11174,$,$); -#11178=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_60','Overhead power supply line support products',#11144,$,$); -#11179=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_60_23','Double insulator catenary cantilever assemblies',#11178,$,$); -#11180=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_60_24','Double insulator trolley wire cantilever assemblies',#11178,$,$); -#11181=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_60_55','Overhead line cable supports',#11178,$,$); -#11182=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_60_56','Overhead line catenary wires',#11178,$,$); -#11183=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_60_57','Overhead line contact wires',#11178,$,$); -#11184=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_60_58','Overhead line droppers',#11178,$,$); -#11185=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_60_59','Overhead line fixings',#11178,$,$); -#11186=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_60_60','Overhead line mounting structures',#11178,$,$); -#11187=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_60_61','Overhead line span wires',#11178,$,$); -#11188=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_60_63','Overhead wiring splices',#11178,$,$); -#11189=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_60_77','Single insulator catenary cantilever assemblies',#11178,$,$); -#11190=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_60_78','Single insulator trolley wire cantilever assemblies',#11178,$,$); -#11191=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97','Wiring accessories',#11144,$,$); -#11192=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_03','Architrave switches',#11191,$,$); -#11193=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_06','Bayonet lamp holders',#11191,$,$); -#11194=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_11','Cable couplers',#11191,$,$); -#11195=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_12','Cable outlet plates',#11191,$,$); -#11196=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_16','Ceiling light switches',#11191,$,$); -#11197=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_17','Ceiling power switches',#11191,$,$); -#11198=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_18','Ceiling roses',#11191,$,$); -#11199=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_20','Cooker control units',#11191,$,$); -#11200=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_21','Cooker connection units',#11191,$,$); -#11201=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_22','Dimmer switches and controls',#11191,$,$); -#11202=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_23','Double pole switches',#11191,$,$); -#11203=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_26','Edison screw lamp holders',#11191,$,$); -#11204=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_27','Electrical connection boxes',#11191,$,$); -#11205=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_28','End brackets',#11191,$,$); -#11206=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_29','Electric vehicle charging points',#11191,$,$); -#11207=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_30','Fan isolators',#11191,$,$); -#11208=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_31','Fused connection units',#11191,$,$); -#11209=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_34','Grid switches',#11191,$,$); -#11210=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_40','Industrial plugs',#11191,$,$); -#11211=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_41','Industrial socket outlets',#11191,$,$); -#11212=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_47','Luminaire supporting couplers',#11191,$,$); -#11213=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_52','Multi-gang power outlets',#11191,$,$); -#11214=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_63','Plate switches',#11191,$,$); -#11215=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_66','Prefabricated wiring switches',#11191,$,$); -#11216=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_72','Round pin socket outlets',#11191,$,$); -#11217=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_75','Safety pendant lamp holders',#11191,$,$); -#11218=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_76','Safety pendant sets',#11191,$,$); -#11219=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_78','Shaver supply units',#11191,$,$); -#11220=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_79','Single voltage shaver outlets',#11191,$,$); -#11221=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_81','Socket outlet residual current devices (SRCD)',#11191,$,$); -#11222=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_82','Specialist socket outlets',#11191,$,$); -#11223=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_83','Surface and concealed wiring enclosures',#11191,$,$); -#11224=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_84','Standard socket outlets',#11191,$,$); -#11225=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_85','Stud terminal covers',#11191,$,$); -#11226=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_86','Stud terminals',#11191,$,$); -#11227=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80','Transport distribution products',#10236,$,$); -#11228=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_06','Baggage handling conveyors',#11227,$,$); -#11229=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15','Cranes and lifting products',#11227,$,$); -#11230=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15_09','Cable slot channels',#11229,$,$); -#11231=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15_11','Cable slot covers',#11229,$,$); -#11232=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15_13','Cable turnover pits',#11229,$,$); -#11233=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15_16','Crane arrestors',#11229,$,$); -#11234=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15_18','Crane stow pin sockets',#11229,$,$); -#11235=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15_22','Detachable hooks',#11229,$,$); -#11236=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15_47','Lifting rings',#11229,$,$); -#11237=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15_48','Lifting trunnions',#11229,$,$); -#11238=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15_59','Overhead travelling cranes',#11229,$,$); -#11239=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15_71','Roof trolleys',#11229,$,$); -#11240=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15_73','Runway tracks',#11229,$,$); -#11241=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15_74','Runway trolleys',#11229,$,$); -#11242=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15_88','Tie down slots',#11229,$,$); -#11243=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_23','Dock levellers',#11227,$,$); -#11244=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_23_06','Bascule dock bridges',#11243,$,$); -#11245=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_23_38','Hydraulic hinged-lip dock levellers',#11243,$,$); -#11246=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_23_39','Hydraulic telescopic-lip dock levellers',#11243,$,$); -#11247=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_23_51','Mechanical dock levellers',#11243,$,$); -#11248=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28','Escalator and moving walk products',#11227,$,$); -#11249=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_04','Escalator and moving walk auxiliary brakes',#11248,$,$); -#11250=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_06','Escalator and moving walk balustrades',#11248,$,$); -#11251=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_07','Escalator and moving walk balustrade newels',#11248,$,$); -#11252=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_09','Escalator and moving walk belts',#11248,$,$); -#11253=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_12','Escalator and moving walk cladding',#11248,$,$); -#11254=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_14','Escalator combs',#11248,$,$); -#11255=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_16','Escalator comb plates',#11248,$,$); -#11256=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_21','Escalators',#11248,$,$); -#11257=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_22','Escalator and moving walk decking',#11248,$,$); -#11258=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_24','Escalator and moving walk drive units',#11248,$,$); -#11259=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_36','Escalator and moving walk handrails',#11248,$,$); -#11260=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_38','Escalator hand winding devices',#11248,$,$); -#11261=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_41','Escalator and moving walk inspection covers',#11248,$,$); -#11262=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_46','Escalator and moving walk landing floor plates',#11248,$,$); -#11263=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_52','Moving walks',#11248,$,$); -#11264=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_58','Escalator and moving walk operational brakes',#11248,$,$); -#11265=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_60','Escalator pallets',#11248,$,$); -#11266=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_78','Escalator and moving walk skirtings',#11248,$,$); -#11267=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_80','Escalator and moving walk skirt deflectors',#11248,$,$); -#11268=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_84','Escalator step treads',#11248,$,$); -#11269=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_89','Moving walk treadway belts',#11248,$,$); -#11270=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_90','Moving walk treadway pallets',#11248,$,$); -#11271=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_42','Inclined transport cars, platforms and chairs',#11227,$,$); -#11272=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_42_11','Cable cars',#11271,$,$); -#11273=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_42_37','Homelifts',#11271,$,$); -#11274=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_42_39','Inclined chairlifts',#11271,$,$); -#11275=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_42_42','Inclined standing platforms',#11271,$,$); -#11276=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_42_43','Inclined wheelchair platforms',#11271,$,$); -#11277=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_42_77','Ski lift chairs',#11271,$,$); -#11278=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_42_84','Stairlift trolleys',#11271,$,$); -#11279=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_46','Laundry conveyors',#11227,$,$); -#11280=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_46_15','Laundry and garment conveyors',#11279,$,$); -#11281=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_46_42','Inclined loading laundry conveyors',#11279,$,$); -#11282=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_46_77','Shuttle lifting laundry conveyors',#11279,$,$); -#11283=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_47','Lifting platforms and hoists',#11227,$,$); -#11284=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_47_04','Assisted transfer hoists',#11283,$,$); -#11285=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_47_12','Ceiling track hoists',#11283,$,$); -#11286=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_47_31','Fixed hoists',#11283,$,$); -#11287=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_47_47','Moveable hoists',#11283,$,$); -#11288=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_47_64','Poolside hoists',#11283,$,$); -#11289=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_47_76','Service hoists',#11283,$,$); -#11290=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_47_84','Step lifts',#11283,$,$); -#11291=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_47_94','Vehicle hoists',#11283,$,$); -#11292=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_47_95','Vertical lifting platforms',#11283,$,$); -#11293=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_47_96','Vertical storage lifts',#11283,$,$); -#11294=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_65','Pneumatic document conveying products',#11227,$,$); -#11295=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_65_63','Pneumatic document conveying blowers',#11294,$,$); -#11296=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_65_64','Pneumatic document conveying carriers',#11294,$,$); -#11297=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_65_65','Pneumatic document conveying diverters',#11294,$,$); -#11298=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_65_66','Pneumatic document conveying pipes and fittings',#11294,$,$); -#11299=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_65_67','Pneumatic document conveying stations',#11294,$,$); -#11300=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_89','Transport cables',#11227,$,$); -#11301=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_89_11','Cable car cables',#11300,$,$); -#11302=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_89_46','Lift cables',#11300,$,$); -#11303=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_89_85','Ski lift cables',#11300,$,$); -#11304=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_96','Wastewater conveyor products',#11227,$,$); -#11305=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_96_07','Belt conveyors',#11304,$,$); -#11306=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_96_24','Drag or chain link conveyors',#11304,$,$); -#11307=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_96_76','Screw conveyors',#11304,$,$); -#11308=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_96_79','Shafted screw conveyors',#11304,$,$); -#11309=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_96_80','Shaftless spiral conveyors',#11304,$,$); -#11310=IFCCLASSIFICATIONREFERENCE($,'Pr_70','Services outlet products',#4921,$,$); -#11311=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50','Solid waste disposal products',#11310,$,$); -#11312=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_71','Refuse disposal equipment',#11311,$,$); -#11313=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_71_18','Crushers',#11312,$,$); -#11314=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_71_42','Incinerators',#11312,$,$); -#11315=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_71_60','Packagers',#11312,$,$); -#11316=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_80','Solid waste balers',#11311,$,$); -#11317=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_80_37','Horizontal balers',#11316,$,$); -#11318=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_80_94','Vertical balers',#11316,$,$); -#11319=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_85','Solid waste compactor products',#11311,$,$); -#11320=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_85_24','Dry waste compactors',#11319,$,$); -#11321=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_85_37','High density compaction extruders',#11319,$,$); -#11322=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_85_65','Portable waste compactors',#11319,$,$); -#11323=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_85_66','Portable waste compactor and bin lifts',#11319,$,$); -#11324=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_85_78','Skip portable waste compactors',#11319,$,$); -#11325=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_85_96','Wet waste compactors',#11319,$,$); -#11326=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55','Liquid and gas outlet products',#11310,$,$); -#11327=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_33','Gas and foam nozzles and sprinklers',#11326,$,$); -#11328=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_33_11','Carbon dioxide fire extinguishing nozzles',#11327,$,$); -#11329=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_33_28','Foam firefighting monitors',#11327,$,$); -#11330=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_33_30','Foam sprinklers',#11327,$,$); -#11331=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_33_36','Halocarbons and inert gas fire extinguishing nozzles',#11327,$,$); -#11332=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42','Irrigation water outlets',#11326,$,$); -#11333=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_09','Bubblers',#11332,$,$); -#11334=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_11','Capillary matting',#11332,$,$); -#11335=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_22','Drippers',#11332,$,$); -#11336=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_46','Lateral pipelines',#11332,$,$); -#11337=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_47','Layered irrigation matting',#11332,$,$); -#11338=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_52','Micro-distribution pipelines',#11332,$,$); -#11339=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_53','Micro-perforated polyethylene sheet',#11332,$,$); -#11340=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_54','Misters',#11332,$,$); -#11341=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_58','Oscillating sprinklers',#11332,$,$); -#11342=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_64','Porous pipelines',#11332,$,$); -#11343=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_70','Rain guns',#11332,$,$); -#11344=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_73','Rotary impact sprinklers',#11332,$,$); -#11345=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_80','Spray jets',#11332,$,$); -#11346=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_90','Tree irrigation rings',#11332,$,$); -#11347=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_51','Medical gases outlets',#11326,$,$); -#11348=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_51_30','Flexible pendants',#11347,$,$); -#11349=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_51_37','Headwall bedhead units',#11347,$,$); -#11350=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_51_52','Terminal units',#11347,$,$); -#11351=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_51_53','Medical trunking bedhead units',#11347,$,$); -#11352=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_51_55','Multi-movement pendants',#11347,$,$); -#11353=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_51_73','Retractable pendants',#11347,$,$); -#11354=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_51_74','Rigid pendants',#11347,$,$); -#11355=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_58','Oil and grease lubricant supply products',#11326,$,$); -#11356=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_58_34','Greases',#11355,$,$); -#11357=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_58_48','Lubricator height adjustors',#11355,$,$); -#11358=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_58_58','Oils',#11355,$,$); -#11359=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_58_68','Rail friction modifier',#11355,$,$); -#11360=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_58_70','Rail lubricators',#11355,$,$); -#11361=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_58_72','Rail traction gels',#11355,$,$); -#11362=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_58_80','Solid lubricants',#11355,$,$); -#11363=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_62','Phase change outlet products',#11326,$,$); -#11364=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_62_27','Foam chambers',#11363,$,$); -#11365=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_62_29','Foam generators',#11363,$,$); -#11366=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_62_31','Foam proportioners',#11363,$,$); -#11367=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_76','Sewage treatment plant',#11326,$,$); -#11368=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_76_34','Geocellular modular plastics storage units',#11367,$,$); -#11369=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_76_62','Private packaged pumping stations',#11367,$,$); -#11370=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_76_64','Private packaged septic tank units',#11367,$,$); -#11371=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_76_66','Private packaged sewage treatment units',#11367,$,$); -#11372=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_76_72','Reed bed units',#11367,$,$); -#11373=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_76_76','Sewage below-ground storage tanks (cesspools)',#11367,$,$); -#11374=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_96','Waste water outlets and plugs',#11326,$,$); -#11375=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_96_06','Bath wastes',#11374,$,$); -#11376=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_96_09','Bidet wastes',#11374,$,$); -#11377=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_96_76','Scrub up trough and wash trough wastes',#11374,$,$); -#11378=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_96_83','Shower tray wastes',#11374,$,$); -#11379=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_96_84','Sink wastes',#11374,$,$); -#11380=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_96_93','Urinal wastes',#11374,$,$); -#11381=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_96_97','Wash basins wastes',#11374,$,$); -#11382=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_96_98','Waste water plugs and chains',#11374,$,$); -#11383=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_97','Water fire extinguishing outlets',#11326,$,$); -#11384=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_97_01','Above-ground fire hydrants',#11383,$,$); -#11385=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_97_23','Domestic sprinkler heads',#11383,$,$); -#11386=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_97_37','High velocity nozzles',#11383,$,$); -#11387=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_97_51','Medium velocity nozzles',#11383,$,$); -#11388=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_97_57','Nozzles',#11383,$,$); -#11389=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_97_84','Sprinkler heads',#11383,$,$); -#11390=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_97_93','Underground fire hydrants',#11383,$,$); -#11391=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_97_96','Water firefighting monitors',#11383,$,$); -#11392=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98','Water inlets and outlets',#11326,$,$); -#11393=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_30','Fountains',#11392,$,$); -#11394=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_35','Green roof drainage outlets',#11392,$,$); -#11395=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_37','High-pressure water hose connectors',#11392,$,$); -#11396=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_46','Laminar jets',#11392,$,$); -#11397=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_59','Overflows',#11392,$,$); -#11398=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_60','Passive tank outlets',#11392,$,$); -#11399=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_65','Pool water inlets',#11392,$,$); -#11400=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_66','Pool water outlets',#11392,$,$); -#11401=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_84','Sprinklers',#11392,$,$); -#11402=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_87','Tape lines and drippers',#11392,$,$); -#11403=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_92','Ultrasonic mist makers',#11392,$,$); -#11404=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_94','Washout hydrants',#11392,$,$); -#11405=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_95','Waterfalls and cascades',#11392,$,$); -#11406=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_96','Water feature nozzles',#11392,$,$); -#11407=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60','Space heating and cooling products',#11310,$,$); -#11408=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_14','Climatic beams and ceilings',#11407,$,$); -#11409=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_14_02','Active climatic beams',#11408,$,$); -#11410=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_14_10','Bulkhead active climatic beams',#11408,$,$); -#11411=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_14_14','Climatic ceiling panels',#11408,$,$); -#11412=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_14_47','Linear active climatic beams',#11408,$,$); -#11413=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_14_53','Modular or cassette active climatic beams',#11408,$,$); -#11414=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_14_55','Multi-service climatic beams',#11408,$,$); -#11415=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_14_60','Passive climatic beams',#11408,$,$); -#11416=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36','Heat emitters',#11407,$,$); -#11417=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_02','Air curtains',#11416,$,$); -#11418=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_06','Cabinet direct heaters',#11416,$,$); -#11419=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_08','Cabinet indirect heaters',#11416,$,$); -#11420=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_15','Constant wattage trace heating cables',#11416,$,$); -#11421=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_22','Decorative fuel effect gas fires',#11416,$,$); -#11422=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_26','Electric heated towel rails',#11416,$,$); -#11423=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_27','Electric cable underfloor heating elements',#11416,$,$); -#11424=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_28','Electric sheet underfloor heating elements',#11416,$,$); -#11425=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_29','Equipment heaters',#11416,$,$); -#11426=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_30','Fan convectors',#11416,$,$); -#11427=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_33','Gas fired unit heaters',#11416,$,$); -#11428=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_35','Gas fires',#11416,$,$); -#11429=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_37','Heat pump driven air curtains',#11416,$,$); -#11430=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_42','Inset live fuel effect gas fires',#11416,$,$); -#11431=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_48','Low temperature hot water (LTHW) heated towel rails',#11416,$,$); -#11432=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_49','Low temperature hot water (LTHW) underfloor heating',#11416,$,$); -#11433=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_52','Mirror heaters',#11416,$,$); -#11434=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_56','Natural convectors',#11416,$,$); -#11435=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_60','Points heater cables',#11416,$,$); -#11436=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_62','Points heating kits',#11416,$,$); -#11437=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_64','Power-limiting trace heating cables',#11416,$,$); -#11438=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_70','Radiant luminous heaters',#11416,$,$); -#11439=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_71','Radiant panels',#11416,$,$); -#11440=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_72','Radiant tube heaters',#11416,$,$); -#11441=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_73','Radiators',#11416,$,$); -#11442=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_74','Room heaters',#11416,$,$); -#11443=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_76','Self-regulating trace heating cables',#11416,$,$); -#11444=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_77','Series resistance trace heating cables and tapes',#11416,$,$); -#11445=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_80','Solid fuel room heaters',#11416,$,$); -#11446=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_88','Thermal storage heaters',#11416,$,$); -#11447=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_90','Trench convectors',#11416,$,$); -#11448=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_93','Unit heaters',#11416,$,$); -#11449=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_97','Wood-burning stoves',#11416,$,$); -#11450=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37','Heat pumps',#11407,$,$); -#11451=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_02','Air to air heat pumps',#11450,$,$); -#11452=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_04','Air to water heat pumps',#11450,$,$); -#11453=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_08','Brine to water heat pumps',#11450,$,$); -#11454=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_25','Dual split gas engine driven heat pumps',#11450,$,$); -#11455=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_33','Gas engine driven heat pumps',#11450,$,$); -#11456=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_34','Gas fired absorption heat pumps',#11450,$,$); -#11457=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_36','Ground source heat pumps',#11450,$,$); -#11458=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_47','Low temperature air to water heat pumps',#11450,$,$); -#11459=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_50','Medium or high temperature air to water heat pumps',#11450,$,$); -#11460=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_52','Multi-split air to air heat pumps',#11450,$,$); -#11461=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_53','Multi-split gas engine driven heat pumps',#11450,$,$); -#11462=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_54','Multi-split variable refrigerant flow (VRF) water to air heat pumps',#11450,$,$); -#11463=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_78','Single split air to air heat pumps',#11450,$,$); -#11464=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_80','Single split gas engine driven heat pumps',#11450,$,$); -#11465=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_82','Single split water to air heat pumps',#11450,$,$); -#11466=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_94','Variable refrigerant flow (VRF) air to air heat pumps',#11450,$,$); -#11467=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_95','Variable refrigerant flow (VRF) gas engine driven heat pumps',#11450,$,$); -#11468=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_96','Water to air heat pumps',#11450,$,$); -#11469=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_98','Water to water heat pumps',#11450,$,$); -#11470=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_60','Pavement heating products',#11407,$,$); -#11471=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_60_37','Pavement heating cables',#11470,$,$); -#11472=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_60_38','Pavement heating mats',#11470,$,$); -#11473=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_82','Space heating fittings and equipment',#11407,$,$); -#11474=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_82_29','Fenders',#11473,$,$); -#11475=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_82_30','Fireplace hearths',#11473,$,$); -#11476=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_82_31','Fireplace hoods',#11473,$,$); -#11477=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_82_32','Fireplace surrounds',#11473,$,$); -#11478=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_82_41','Inset open fireplace firebacks',#11473,$,$); -#11479=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_82_42','Inset open fireplace surrounds and hearths',#11473,$,$); -#11480=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_82_43','Inset open fires',#11473,$,$); -#11481=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65','Air and fume outlet products',#11310,$,$); -#11482=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03','Air conditioning units',#11481,$,$); -#11483=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03_01','Adiabatic coolers',#11482,$,$); -#11484=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03_02','Air cooled condensing units',#11482,$,$); -#11485=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03_25','Dry air coolers',#11482,$,$); -#11486=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03_27','Evaporative cooling units',#11482,$,$); -#11487=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03_29','Fan coil units',#11482,$,$); -#11488=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03_41','Indirect evaporative cooling units',#11482,$,$); -#11489=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03_42','Indoor refrigeration units',#11482,$,$); -#11490=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03_43','Induction units',#11482,$,$); -#11491=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03_47','Local air conditioning units',#11482,$,$); -#11492=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03_72','Room air conditioning units',#11482,$,$); -#11493=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03_84','Split coil remote air cooled condensing units',#11482,$,$); -#11494=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03_86','Split coil room air conditioning units',#11482,$,$); -#11495=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03_94','Variable refrigerant flow units',#11482,$,$); -#11496=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04','Air terminals and diffusers',#11481,$,$); -#11497=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_02','Air diffusers',#11496,$,$); -#11498=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_03','Air grilles',#11496,$,$); -#11499=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_04','Air plenum boxes',#11496,$,$); -#11500=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_22','Displacement ventilation diffusers',#11496,$,$); -#11501=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_24','Domestic air diffusers and grilles',#11496,$,$); -#11502=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_25','Dual duct variable air volume (VAV) terminal units',#11496,$,$); -#11503=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_28','External wall grilles',#11496,$,$); -#11504=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_30','Floor linear air diffusers',#11496,$,$); -#11505=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_32','Floor-mounted air plenum boxes',#11496,$,$); -#11506=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_44','Jet diffusers',#11496,$,$); -#11507=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_46','Laminar flow panels',#11496,$,$); -#11508=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_48','Linear air diffusers',#11496,$,$); -#11509=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_53','Modular cassette ventilated ceilings',#11496,$,$); -#11510=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_56','Natural smoke and heat exhaust ventilators',#11496,$,$); -#11511=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_73','Roof ridge air terminals',#11496,$,$); -#11512=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_75','Roof slope air terminals',#11496,$,$); -#11513=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_76','Roof stack air terminals',#11496,$,$); -#11514=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_77','Roof ventilator cowls',#11496,$,$); -#11515=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_84','Specialist air terminals',#11496,$,$); -#11516=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_86','Swirl air diffusers',#11496,$,$); -#11517=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_88','Terminal fan units',#11496,$,$); -#11518=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_91','Variable air volume (VAV) fan assisted and heated terminal units',#11496,$,$); -#11519=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_92','Variable air volume (VAV) heated terminal units',#11496,$,$); -#11520=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_93','Variable air volume (VAV) fan assisted terminal units',#11496,$,$); -#11521=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_94','Variable air volume (VAV) terminal units',#11496,$,$); -#11522=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_95','Ventilated ceilings',#11496,$,$); -#11523=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_30','Flues and chimneys',#11481,$,$); -#11524=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_30_14','Clay chimney pots',#11523,$,$); -#11525=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_30_15','Clay flue liner terminals',#11523,$,$); -#11526=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_30_16','Concrete chimney pots',#11523,$,$); -#11527=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_30_30','Flue liners',#11523,$,$); -#11528=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_30_32','Fume extract discharge stacks',#11523,$,$); -#11529=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_30_51','Metal flues and chimneys',#11523,$,$); -#11530=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_30_84','Stainless steel chimney pots',#11523,$,$); -#11531=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70','Power and lighting outlet products',#11310,$,$); -#11532=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46','Lamps',#11531,$,$); -#11533=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_15','Compact fluorescent lamps',#11532,$,$); -#11534=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_24','Double capped tubular LED lamps',#11532,$,$); -#11535=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_30','Fluorescent lamps',#11532,$,$); -#11536=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_36','High pressure mercury vapour lamps',#11532,$,$); -#11537=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_37','High pressure sodium vapour lamps',#11532,$,$); -#11538=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_41','Induction lamps',#11532,$,$); -#11539=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_42','Infrared lamps',#11532,$,$); -#11540=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_44','Light-emitting diode (LED) lamps',#11532,$,$); -#11541=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_45','Low pressure sodium vapour lamps',#11532,$,$); -#11542=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_52','Metal halide lamps',#11532,$,$); -#11543=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_77','Self ballasted compact fluorescent lamps',#11532,$,$); -#11544=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_78','Self ballasted LED lamps',#11532,$,$); -#11545=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_80','Special lamps',#11532,$,$); -#11546=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_89','Tungsten filament lamps',#11532,$,$); -#11547=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_90','Tungsten halogen lamps',#11532,$,$); -#11548=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47','Lighting controls and lighting distribution products',#11531,$,$); -#11549=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_02','Automatic emergency lighting test panels',#11548,$,$); -#11550=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_12','Centralized lighting controllers',#11548,$,$); -#11551=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_16','Combined daylight and occupancy detectors',#11548,$,$); -#11552=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_21','Daylight sensors',#11548,$,$); -#11553=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_27','Extra low voltage lighting transformers',#11548,$,$); -#11554=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_28','Extra low voltage occupancy detectors',#11548,$,$); -#11555=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_47','Luminaire changeover relays',#11548,$,$); -#11556=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_48','Luminaire hold-off relays',#11548,$,$); -#11557=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_49','Luminaire inverter modules',#11548,$,$); -#11558=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_50','Luminaire sub-circuit relays',#11548,$,$); -#11559=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_51','Mains voltage occupancy detectors',#11548,$,$); -#11560=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_62','Photoelectric control units',#11548,$,$); -#11561=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_71','Remote infrared lighting commissioning controllers',#11548,$,$); -#11562=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_72','Remote infrared lighting user controllers',#11548,$,$); -#11563=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48','Luminaires, lighting track and lighting accessories',#11531,$,$); -#11564=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_02','Area floodlights',#11563,$,$); -#11565=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_13','Chandeliers',#11563,$,$); -#11566=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_15','Combined downlight and uplights',#11563,$,$); -#11567=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_16','Combined emergency luminaires',#11563,$,$); -#11568=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_23','Dedicated slave emergency luminaires',#11563,$,$); -#11569=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_24','Downlights',#11563,$,$); -#11570=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_26','Electrical low mounted way-guidance lighting module housings',#11563,$,$); -#11571=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_27','Electrical low mounted way-guidance lighting modules',#11563,$,$); -#11572=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_28','Electrical low mounted way-guidance lighting supply units',#11563,$,$); -#11573=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_29','Electronic ballasts',#11563,$,$); -#11574=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_30','Electronic starters',#11563,$,$); -#11575=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_32','Free standing luminaires',#11563,$,$); -#11576=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_35','Ground mounted luminaires',#11563,$,$); -#11577=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_36','Hazardous area luminaires',#11563,$,$); -#11578=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_45','LED light panels',#11563,$,$); -#11579=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_47','Lighting tracks',#11563,$,$); -#11580=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_48','Luminaire smoke hoods',#11563,$,$); -#11581=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_59','Optical fibre emergency luminaires',#11563,$,$); -#11582=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_62','Pendant luminaires',#11563,$,$); -#11583=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_65','Post top lanterns',#11563,$,$); -#11584=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_70','Recessed downlights',#11563,$,$); -#11585=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_71','Recessed luminaires',#11563,$,$); -#11586=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_73','Road lighting luminaires',#11563,$,$); -#11587=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_77','Self-contained emergency luminaires',#11563,$,$); -#11588=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_80','Sockets for demountable lighting',#11563,$,$); -#11589=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_82','Spot lights',#11563,$,$); -#11590=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_85','Surface luminaires',#11563,$,$); -#11591=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_86','Suspended luminaires',#11563,$,$); -#11592=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_92','Underwater luminaires',#11563,$,$); -#11593=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_93','Uplights',#11563,$,$); -#11594=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_70','Rail power products',#11531,$,$); -#11595=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_70_15','Conductor rail power connectors',#11594,$,$); -#11596=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75','Communications products',#11310,$,$); -#11597=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_01','Aeronautical lighting products',#11596,$,$); -#11598=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_01_01','Aeronautical ground lighting',#11597,$,$); -#11599=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_01_02','Airfield guidance signs',#11597,$,$); -#11600=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_01_03','Azimuth guidance for nose-in stand (AGNIS) lights',#11597,$,$); -#11601=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_01_13','Constant current regulators',#11597,$,$); -#11602=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_01_47','Lighting beacons',#11597,$,$); -#11603=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_01_65','Precision approach path indicators (PAPI)',#11597,$,$); -#11604=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_01_70','Runway and taxiway elevated lights',#11597,$,$); -#11605=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_01_71','Runway and taxiway inset lights',#11597,$,$); -#11606=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04','Audio, data and visual outlet plates and controllers',#11596,$,$); -#11607=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_03','Audio interface adaptors',#11606,$,$); -#11608=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_06','Balanced twisted-pair cable outlet plates',#11606,$,$); -#11609=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_25','DVI outlet plates',#11606,$,$); -#11610=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_29','Fibre optic cable outlet plates',#11606,$,$); -#11611=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_37','HDMI outlet plates',#11606,$,$); -#11612=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_42','Input and output control port expanders',#11606,$,$); -#11613=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_52','Modular jacks',#11606,$,$); -#11614=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_70','RCA outlet plates',#11606,$,$); -#11615=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_71','RJ-45 to BT plug adaptors',#11606,$,$); -#11616=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_85','SVGA outlet plates',#11606,$,$); -#11617=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_88','Telecommunications outlet plates',#11606,$,$); -#11618=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_90','Television outlet plates',#11606,$,$); -#11619=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_94','Volume controllers',#11606,$,$); -#11620=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_99','XLR outlet plates',#11606,$,$); -#11621=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36','Hearing and assisted listening products',#11596,$,$); -#11622=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_08','Bodypack receivers',#11621,$,$); -#11623=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_36','Headphones',#11621,$,$); -#11624=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_37','Headsets',#11621,$,$); -#11625=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_40','Induction loop amplifiers',#11621,$,$); -#11626=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_41','Induction loop pads',#11621,$,$); -#11627=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_42','Induction loop signal generators',#11621,$,$); -#11628=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_43','Induction loop transformers',#11621,$,$); -#11629=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_44','Induction neck loops',#11621,$,$); -#11630=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_45','Induction-loop monitor receivers',#11621,$,$); -#11631=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_46','Induction loop reassurance indicators',#11621,$,$); -#11632=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_47','Infrared hearing and assisted listening modulators',#11621,$,$); -#11633=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_48','Infrared hearing and assisted listening radiators',#11621,$,$); -#11634=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_50','Loudspeakers',#11621,$,$); -#11635=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_51','Loudspeaker end of line units',#11621,$,$); -#11636=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_64','Portable communicators',#11621,$,$); -#11637=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_84','Stethosets',#11621,$,$); -#11638=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_52','Mesh network products',#11596,$,$); -#11639=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_52_01','3G gateway modems',#11638,$,$); -#11640=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_52_42','Intelligent access points (IAPs)',#11638,$,$); -#11641=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_52_50','Mesh wireless routers',#11638,$,$); -#11642=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_52_56','Network switches',#11638,$,$); -#11643=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_52_64','Power over ethernet (POE) network switches',#11638,$,$); -#11644=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_52_88','Tilt sensor nodes',#11638,$,$); -#11645=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_52_92','USB gateway modems',#11638,$,$); -#11646=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_52_96','Wireless sensor nodes',#11638,$,$); -#11647=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_69','Radio communications products',#11596,$,$); -#11648=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_69_70','Radio base stations',#11647,$,$); -#11649=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70','Rail signals, indicators and controls',#11596,$,$); -#11650=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_03','Automatic warning signals',#11649,$,$); -#11651=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_05','Axle counters',#11649,$,$); -#11652=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_06','Banner repeater signals',#11649,$,$); -#11653=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_07','Balises',#11649,$,$); -#11654=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_14','Colour light signals',#11649,$,$); -#11655=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_41','In-cab signalling displays',#11649,$,$); -#11656=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_44','Junction indicators',#11649,$,$); -#11657=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_47','Limit of shunt signals',#11649,$,$); -#11658=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_60','Platform repeaters',#11649,$,$); -#11659=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_61','Points detection equipment',#11649,$,$); -#11660=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_62','Points converter devices',#11649,$,$); -#11661=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_63','Points operating equipment',#11649,$,$); -#11662=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_64','Position light signals',#11649,$,$); -#11663=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_65','Possession limit boards',#11649,$,$); -#11664=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_70','Rail gap indicator signals',#11649,$,$); -#11665=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_72','Route indicators',#11649,$,$); -#11666=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_76','Semaphore disc signals',#11649,$,$); -#11667=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_77','Semaphore signals',#11649,$,$); -#11668=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_78','Semaphore subsidiary signals',#11649,$,$); -#11669=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_80','Signalling relays',#11649,$,$); -#11670=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_89','Track circuits',#11649,$,$); -#11671=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_90','Train protection warning signals',#11649,$,$); -#11672=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_91','Treadles',#11649,$,$); -#11673=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72','Road traffic and pedestrian control signals',#11596,$,$); -#11674=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_01','Above ground vehicle detection products',#11673,$,$); -#11675=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_07','Belisha beacons',#11673,$,$); -#11676=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_22','Detector loops',#11673,$,$); -#11677=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_30','Fixed vertical road traffic signs',#11673,$,$); -#11678=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_48','Level crossing signals',#11673,$,$); -#11679=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_49','Mass detectors',#11673,$,$); -#11680=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_50','Motorway lane signals',#11673,$,$); -#11681=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_51','Motorway signal mark 1',#11673,$,$); -#11682=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_53','Motorway signal mark 3',#11673,$,$); -#11683=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_54','Motorway signal mark 4',#11673,$,$); -#11684=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_60','Pedestrian signal controllers',#11673,$,$); -#11685=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_61','Pedestrian crossing signals',#11673,$,$); -#11686=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_80','Solar powered illuminated bollards',#11673,$,$); -#11687=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_87','Traffic signal controller units',#11673,$,$); -#11688=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_89','Transilluminated traffic bollards',#11673,$,$); -#11689=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_92','Urban traffic management signs',#11673,$,$); -#11690=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_94','Variable message traffic signs',#11673,$,$); -#11691=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_95','Vehicle activated signs',#11673,$,$); -#11692=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_96','Vehicular traffic signals',#11673,$,$); -#11693=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_98','Wig wag signals',#11673,$,$); -#11694=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_99','Wig wag signal control units',#11673,$,$); -#11695=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_80','Sports timing and scoring equipment',#11596,$,$); -#11696=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_80_27','Electronic scoreboards',#11695,$,$); -#11697=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_80_46','Lane boxes',#11695,$,$); -#11698=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_80_48','Lane manual push buttons',#11695,$,$); -#11699=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_80_50','Manual scoreboards',#11695,$,$); -#11700=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_80_72','Relay race break sensors',#11695,$,$); -#11701=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_80_82','Swimmers starting blocks',#11695,$,$); -#11702=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_80_83','Swimmers touch pads',#11695,$,$); -#11703=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_80_84','Swimming race start sound generators',#11695,$,$); -#11704=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_80_85','Swimming timing controllers',#11695,$,$); -#11705=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_88','Telecoms equipment',#11596,$,$); -#11706=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_88_01','Acoustic hoods',#11705,$,$); -#11707=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_88_03','Analogue telephone handsets',#11705,$,$); -#11708=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_88_21','Data and telecom transient overvoltage surge suppression devices',#11705,$,$); -#11709=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_88_22','Digital enhanced cordless telecommunications (DECT) telephone handsets',#11705,$,$); -#11710=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_88_24','Digital terminals',#11705,$,$); -#11711=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_88_27','Emergency roadside telephones',#11705,$,$); -#11712=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_88_60','Payphones',#11705,$,$); -#11713=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_88_83','Telecommunications system controllers',#11705,$,$); -#11714=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_88_86','Telephone distribution frames',#11705,$,$); -#11715=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_88_87','Telephone extension ringers',#11705,$,$); -#11716=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_88_89','Telephone operator consoles',#11705,$,$); -#11717=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_94','Visual and audible indicators',#11596,$,$); -#11718=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_94_27','Electric door bells',#11717,$,$); -#11719=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_94_28','Electronic sounders',#11717,$,$); -#11720=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_94_29','Flashing filament warning beacons',#11717,$,$); -#11721=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_94_40','Indicator lights',#11717,$,$); -#11722=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_94_42','Industrial bells',#11717,$,$); -#11723=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_94_46','LED warning beacons',#11717,$,$); -#11724=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_94_58','Overdoor indicator units',#11717,$,$); -#11725=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_94_60','Panel mounting indicator lights',#11717,$,$); -#11726=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_94_73','Rotating warning beacons',#11717,$,$); -#11727=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_94_78','Starting strobe lights',#11717,$,$); -#11728=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_94_80','Static filament warning beacons',#11717,$,$); -#11729=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_94_99','Xenon warning beacons',#11717,$,$); -#11730=IFCCLASSIFICATIONREFERENCE($,'Pr_75','Services control products',#4921,$,$); -#11731=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30','Opening control products',#11730,$,$); -#11732=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23','Door and gate operating hardware',#11731,$,$); -#11733=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_00','Articulated arm swing gate operators',#11732,$,$); -#11734=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_01','Automatic door access control mats',#11732,$,$); -#11735=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_02','Automatic door presence safety sensors',#11732,$,$); -#11736=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_03','Automatic gate presence safety sensors',#11732,$,$); -#11737=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_04','Automatic sliding door operator control panels',#11732,$,$); -#11738=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_05','Automatic sliding door operators',#11732,$,$); -#11739=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_06','Automatic sliding gate operator control panels',#11732,$,$); -#11740=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_07','Automatic swing door operator control panels',#11732,$,$); -#11741=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_08','Automatic swing gate operator control panels',#11732,$,$); -#11742=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_09','Automatic swing-door operators',#11732,$,$); -#11743=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_21','Dock leveller controllers',#11732,$,$); -#11744=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_22','Door access control pushpads',#11732,$,$); -#11745=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_26','Electromagnetic door holders',#11732,$,$); -#11746=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_27','Electromagnetic door hold-open and swing-free devices',#11732,$,$); -#11747=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_31','Folding gate automation mechanisms',#11732,$,$); -#11748=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_33','Garage door operators',#11732,$,$); -#11749=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_36','Handheld door and gate remote controllers',#11732,$,$); -#11750=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_40','Hinged and swing gate automation mechanisms',#11732,$,$); -#11751=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_42','Hydraulic automation mechanisms',#11732,$,$); -#11752=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_70','Rack and pinion sliding gate operators',#11732,$,$); -#11753=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_72','Rising arm automation mechanisms',#11732,$,$); -#11754=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_76','Sliding gate automation mechanisms',#11732,$,$); -#11755=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_92','Underground swing gate operators',#11732,$,$); -#11756=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_94','Vehicle induction loop detectors',#11732,$,$); -#11757=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_96','Worm drive swing gate operators',#11732,$,$); -#11758=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_27','Electric door locking hardware',#11731,$,$); -#11759=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_27_26','Electric strikes and faceplates',#11758,$,$); -#11760=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_27_27','Electromechanical door locks',#11758,$,$); -#11761=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_27_50','Magnetic locks',#11758,$,$); -#11762=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_27_51','Magnetic shear locks and strike plates',#11758,$,$); -#11763=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_27_77','Shear locks and strike plates',#11758,$,$); -#11764=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_27_80','Solenoid bolts',#11758,$,$); -#11765=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_27_81','Solenoid latches and locks',#11758,$,$); -#11766=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50','Mechanical and electrical services control products',#11730,$,$); -#11767=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18','Controllers and control panels',#11766,$,$); -#11768=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_02','Alarms',#11767,$,$); -#11769=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_04','Automatic sprinkler system indicator panels',#11767,$,$); -#11770=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_06','Automatic sprinkler electric pump control panels',#11767,$,$); -#11771=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_10','Bus section control panels',#11767,$,$); -#11772=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_11','Cableways section panels',#11767,$,$); -#11773=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_13','Chain actuators',#11767,$,$); -#11774=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_15','Compressed air master controllers',#11767,$,$); -#11775=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_16','Control circuit supplies panels',#11767,$,$); -#11776=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_17','Control panels',#11767,$,$); -#11777=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_21','Damper actuators',#11767,$,$); -#11778=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_26','Electric trace heating control and monitoring panels',#11767,$,$); -#11779=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_28','Feeder section control panels',#11767,$,$); -#11780=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_29','Field controllers',#11767,$,$); -#11781=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_30','Flow sample gas detection control panels',#11767,$,$); -#11782=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_31','Fire system indicator panels',#11767,$,$); -#11783=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_32','FIre electric pump control panels',#11767,$,$); -#11784=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_33','Gas detection control panels',#11767,$,$); -#11785=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_34','Gas dose regulators',#11767,$,$); -#11786=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_37','Help point control panels',#11767,$,$); -#11787=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_40','Incoming supply control panels',#11767,$,$); -#11788=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_41','Instrumentation, automation and control panels',#11767,$,$); -#11789=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_42','Irrigation control panels',#11767,$,$); -#11790=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_45','Lift control panels',#11767,$,$); -#11791=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_46','Linear actuators',#11767,$,$); -#11792=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_47','Liquid leak detection control panels',#11767,$,$); -#11793=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_51','Mechanical services control panels',#11767,$,$); -#11794=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_53','Motor starters control panels',#11767,$,$); -#11795=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_65','Pneumatic document conveyor control panels',#11767,$,$); -#11796=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_66','Points heating control panels',#11767,$,$); -#11797=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_67','Power factor correction control panels',#11767,$,$); -#11798=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_69','Power quality filter section panels',#11767,$,$); -#11799=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_70','Programmers',#11767,$,$); -#11800=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_80','Smoke and heat exhaust control panels',#11767,$,$); -#11801=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_82','Solar collector control units',#11767,$,$); -#11802=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_90','Telemetry control panels',#11767,$,$); -#11803=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_92','Uninterruptible power supply control panels',#11767,$,$); -#11804=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_93','Utility supply control panels',#11767,$,$); -#11805=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_94','Valve actuators',#11767,$,$); -#11806=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_96','Water display controls',#11767,$,$); -#11807=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_98','Water quality controllers',#11767,$,$); -#11808=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_99','Wind operated water display control devices',#11767,$,$); -#11809=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_33','Gas fire extinguishing controls',#11766,$,$); -#11810=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_33_25','Electrical actuation devices',#11809,$,$); -#11811=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_33_26','Emergency abort devices',#11809,$,$); -#11812=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_33_27','Emergency hold devices',#11809,$,$); -#11813=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_33_28','Extinguishing control panels',#11809,$,$); -#11814=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_33_50','Manual triggering devices',#11809,$,$); -#11815=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_33_56','Non-electrical gas fire extinguishing disable devices',#11809,$,$); -#11816=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_33_64','Pneumatic heat actuators',#11809,$,$); -#11817=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_33_88','Thermal links',#11809,$,$); -#11818=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_46','Liquid level controllers and switches',#11766,$,$); -#11819=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_46_27','Electronic liquid level controllers',#11818,$,$); -#11820=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_46_29','Float liquid level controllers',#11818,$,$); -#11821=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_46_30','Float switches',#11818,$,$); -#11822=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_46_31','Flush control devices',#11818,$,$); -#11823=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_46_42','Infrared flush controllers',#11818,$,$); -#11824=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_46_46','Level controls and alarms',#11818,$,$); -#11825=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_46_68','Push button flush controllers',#11818,$,$); -#11826=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47','Liquid level sensors',#11766,$,$); -#11827=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_08','Buoyancy level sensors and switches',#11826,$,$); -#11828=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_11','Capacitance and inductance sensors',#11826,$,$); -#11829=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_34','Gravimetric and load cell sensors',#11826,$,$); -#11830=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_35','Guided wave radar sensors',#11826,$,$); -#11831=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_39','Hydrostatic sensors',#11826,$,$); -#11832=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_50','Magnetic level gauge switches',#11826,$,$); -#11833=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_51','Magnetorestrictive level transmitters',#11826,$,$); -#11834=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_53','Maximum water level recorders',#11826,$,$); -#11835=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_70','Radar sensors',#11826,$,$); -#11836=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_73','Rotary paddle sensors',#11826,$,$); -#11837=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_88','Thermal dispersion level switches',#11826,$,$); -#11838=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_92','Ultrasonic sensors',#11826,$,$); -#11839=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_94','Vibrating sensors',#11826,$,$); -#11840=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_96','Water level gauge boards',#11826,$,$); -#11841=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_97','Water level sensors',#11826,$,$); -#11842=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_48','Liquid sensing devices',#11766,$,$); -#11843=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_48_15','Chemical sensing cables',#11842,$,$); -#11844=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_48_31','Fuel sensing cables',#11842,$,$); -#11845=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_48_34','Ground water monitors',#11842,$,$); -#11846=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_48_47','Leak sensing tapes',#11842,$,$); -#11847=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_48_60','Pad leak sensors',#11842,$,$); -#11848=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_48_67','Probe leak sensors',#11842,$,$); -#11849=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_48_71','Remote sampling equipment',#11842,$,$); -#11850=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_48_90','Transportable monitors',#11842,$,$); -#11851=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_48_96','Water sensing cables',#11842,$,$); -#11852=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_50','Measuring and monitoring relays',#11766,$,$); -#11853=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_50_63','Phase monitoring relays',#11852,$,$); -#11854=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_51','Medical gases controls',#11766,$,$); -#11855=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_51_52','Medical gas area alarm panels',#11854,$,$); -#11856=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_51_54','Medical gases central alarms',#11854,$,$); -#11857=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_51_71','Remote start medical gas switch panels',#11854,$,$); -#11858=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_51_94','Vacuum insulated evaporator (VIE) control panels',#11854,$,$); -#11859=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_52','Meteorological instrumentation',#11766,$,$); -#11860=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_52_03','Anemometers',#11859,$,$); -#11861=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_52_06','Barometers',#11859,$,$); -#11862=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_52_12','Ceilometers',#11859,$,$); -#11863=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_52_39','Humidity and temperature probes',#11859,$,$); -#11864=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_52_65','Present weather sensors',#11859,$,$); -#11865=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_52_85','Storage rain gauges',#11859,$,$); -#11866=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_52_90','Tipping bucket rain gauges',#11859,$,$); -#11867=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_52_94','Visibility sensors',#11859,$,$); -#11868=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_52_97','Weather stations',#11859,$,$); -#11869=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_52_98','Weighing rain gauges',#11859,$,$); -#11870=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76','Sensors and detectors',#11766,$,$); -#11871=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_02','Air quality sensors',#11870,$,$); -#11872=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_03','Air temperature sensors',#11870,$,$); -#11873=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_04','Ambient noise level sensors',#11870,$,$); -#11874=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_12','Carbon monoxide detectors',#11870,$,$); -#11875=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_16','Combined electronic current and voltage transducers',#11870,$,$); -#11876=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_17','Combustion gas detectors',#11870,$,$); -#11877=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_18','Current sensors',#11870,$,$); -#11878=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_23','Disinfectant sensors',#11870,$,$); -#11879=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_24','Dissolved oxygen sensors',#11870,$,$); -#11880=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_25','Dry rot sensor sticks',#11870,$,$); -#11881=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_27','Electronic trace heating thermostats',#11870,$,$); -#11882=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_30','Flow in duct sensors',#11870,$,$); -#11883=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_31','Flow in pipe sensors',#11870,$,$); -#11884=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_33','Gas detectors',#11870,$,$); -#11885=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_47','Liquid temperature sensors',#11870,$,$); -#11886=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_51','Mechanical trace heating thermostats',#11870,$,$); -#11887=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_58','Occupancy sensors',#11870,$,$); -#11888=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_59','Passive infrared (PIR) sensors',#11870,$,$); -#11889=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_60','pH value sensors',#11870,$,$); -#11890=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_61','pH sensors',#11870,$,$); -#11891=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_63','Photoelectric sensors',#11870,$,$); -#11892=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_68','Pressure sensors',#11870,$,$); -#11893=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_69','Proximity sensors and control units',#11870,$,$); -#11894=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_71','Relative humidity sensors',#11870,$,$); -#11895=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_72','Residual chlorine sensors',#11870,$,$); -#11896=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_73','Room temperature sensors',#11870,$,$); -#11897=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_80','Sludge density sensors',#11870,$,$); -#11898=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_83','Steam and condensate sensor chambers',#11870,$,$); -#11899=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_84','Steam and condensate sensors',#11870,$,$); -#11900=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_86','Suspended solids sensors',#11870,$,$); -#11901=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_88','Toxic and combustible gas detectors',#11870,$,$); -#11902=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_90','Turbidity sensors',#11870,$,$); -#11903=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_95','Voltage sensors',#11870,$,$); -#11904=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_97','Water pressure sensors',#11870,$,$); -#11905=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51','Motors, motor controls, control circuit devices and timeswitches',#11730,$,$); -#11906=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_17','Control circuit devices and timeswitches',#11905,$,$); -#11907=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_17_27','Emergency stop buttons',#11906,$,$); -#11908=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_17_50','Manual control switches',#11906,$,$); -#11909=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_17_66','Push button switches',#11906,$,$); -#11910=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_17_75','Safety limit switches',#11906,$,$); -#11911=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_17_78','Selector switches',#11906,$,$); -#11912=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_17_87','Tariff and load control radio tele-switches',#11906,$,$); -#11913=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_17_88','Tariff and load control time switches',#11906,$,$); -#11914=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_17_89','Time switches',#11906,$,$); -#11915=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_26','Electric motors',#11905,$,$); -#11916=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_26_00','Alternating current (a.c.) capacitor start capacitor run motors',#11915,$,$); -#11917=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_26_01','Alternating current (a.c.) capacitor motors',#11915,$,$); -#11918=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_26_02','Alternating current (a.c.) split phase motors',#11915,$,$); -#11919=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_26_03','Alternating current (a.c.) squirrel cage induction motors',#11915,$,$); -#11920=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_26_04','Alternating current (a.c.) wound rotor induction motors',#11915,$,$); -#11921=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_26_21','Direct current (d.c.) compound wound motors',#11915,$,$); -#11922=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_26_22','Direct current (d.c.) permanent magnet motors',#11915,$,$); -#11923=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_26_23','Direct current (d.c.) separately excited motors',#11915,$,$); -#11924=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_26_24','Direct current (d.c.) series wound motors',#11915,$,$); -#11925=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_26_25','Direct current (d.c.) shunt wound motors',#11915,$,$); -#11926=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_26_92','Universal motors',#11915,$,$); -#11927=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_35','Gearboxes',#11905,$,$); -#11928=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_35_10','Bevel gearboxes',#11927,$,$); -#11929=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_35_35','Helical gearboxes',#11927,$,$); -#11930=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_35_65','Planetary gearboxes',#11927,$,$); -#11931=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_35_80','Spur gearboxes',#11927,$,$); -#11932=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_35_94','Variable speed hydraulic gearboxes',#11927,$,$); -#11933=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_35_97','Worm gearboxes',#11927,$,$); -#11934=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_52','Motor starters, variable frequency drives and contactors',#11905,$,$); -#11935=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_52_01','Alternating current (a.c.) drives',#11934,$,$); -#11936=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_52_02','Alternating current (a.c.) semiconductor motor controllers and starters',#11934,$,$); -#11937=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_52_15','Control and protective switching devices',#11934,$,$); -#11938=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_52_22','Direct-on-line starters',#11934,$,$); -#11939=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_52_26','Electro-mechanical contactors',#11934,$,$); -#11940=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_52_27','Electromechanical control circuit devices',#11934,$,$); -#11941=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_52_58','Overload relays',#11934,$,$); -#11942=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_52_82','Star delta starters',#11934,$,$); -#11943=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_65','Pneumatic motors',#11905,$,$); -#11944=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_65_05','Axial piston motors',#11943,$,$); -#11945=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_65_70','Radial piston motors',#11943,$,$); -#11946=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_65_73','Rotary vane motors',#11943,$,$); -#11947=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_65_90','Turbine air motors',#11943,$,$); -#11948=IFCCLASSIFICATIONREFERENCE($,'Pr_75_70','Power and lighting control products',#11730,$,$); -#11949=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75','Communications control products',#11730,$,$); -#11950=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04','Assistance and nurse call devices and control equipment',#11949,$,$); -#11951=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_00','Assistance call acoustic hoods',#11950,$,$); -#11952=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_01','Assistance call indicator units',#11950,$,$); -#11953=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_02','Assistance call power supply units',#11950,$,$); -#11954=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_03','Assistance call press button units',#11950,$,$); -#11955=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_04','Assistance call pull cord units',#11950,$,$); -#11956=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_05','Assistance call reset units',#11950,$,$); -#11957=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_57','Nurse call buttons',#11950,$,$); -#11958=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_58','Nurse call combined emergency/ patient call/ reset units',#11950,$,$); -#11959=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_60','Nurse call overdoor indicators',#11950,$,$); -#11960=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_61','Nurse call patient handsets',#11950,$,$); -#11961=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_62','Nurse call patient pull cords',#11950,$,$); -#11962=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_63','Nurse call power supply units',#11950,$,$); -#11963=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_64','Nurse call reset units',#11950,$,$); -#11964=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_65','Nurse call station indicator panels',#11950,$,$); -#11965=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_66','Nurse emergency pull-switches',#11950,$,$); -#11966=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_70','Passenger assistance help points',#11950,$,$); -#11967=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_71','Passenger assistance intercom handsets',#11950,$,$); -#11968=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15','Computers and peripherals',#11949,$,$); -#11969=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_11','Card printers',#11968,$,$); -#11970=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_14','Combined photocopier- printer- scanners',#11968,$,$); -#11971=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_15','Computer keyboards',#11968,$,$); -#11972=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_16','Computer monitors',#11968,$,$); -#11973=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_17','Computer mouse',#11968,$,$); -#11974=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_21','Desktop computers',#11968,$,$); -#11975=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_22','Digital cameras',#11968,$,$); -#11976=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_24','Display screen monitors',#11968,$,$); -#11977=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_36','Hard disk drives',#11968,$,$); -#11978=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_45','Keyboard extenders',#11968,$,$); -#11979=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_46','Laptop computers',#11968,$,$); -#11980=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_63','Photocopiers',#11968,$,$); -#11981=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_66','Printers',#11968,$,$); -#11982=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_76','Scanners',#11968,$,$); -#11983=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_80','Servers',#11968,$,$); -#11984=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_84','Slot card cages',#11968,$,$); -#11985=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_87','Tablet computers',#11968,$,$); -#11986=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_90','Touchscreen monitors',#11968,$,$); -#11987=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27','Electronic access control products',#11949,$,$); -#11988=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_01','Access control digital keypads - standalone',#11987,$,$); -#11989=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_03','Access control units',#11987,$,$); -#11990=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_05','Active proximity devices',#11987,$,$); -#11991=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_07','Biometric fingerprint readers',#11987,$,$); -#11992=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_08','Biometric hand geometry readers',#11987,$,$); -#11993=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_23','Door status monitoring devices',#11987,$,$); -#11994=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_27','Emergency door release break glass units',#11987,$,$); -#11995=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_28','Emergency door release mechanisms',#11987,$,$); -#11996=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_42','Intercom entrance panels',#11987,$,$); -#11997=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_43','Intercom remote handsets',#11987,$,$); -#11998=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_44','Intercom servers',#11987,$,$); -#11999=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_50','Magnetic swipe card readers',#11987,$,$); -#12000=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_51','Magnetic swipe cards',#11987,$,$); -#12001=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_55','Multiple technology cards',#11987,$,$); -#12002=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_57','Multi-technology readers',#11987,$,$); -#12003=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_60','Passive proximity devices',#11987,$,$); -#12004=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_67','Proximity card readers',#11987,$,$); -#12005=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_68','Proximity cards',#11987,$,$); -#12006=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_71','Request-to-exit buttons',#11987,$,$); -#12007=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_72','Request to exit detectors',#11987,$,$); -#12008=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_80','Smart card readers and writers',#11987,$,$); -#12009=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_82','Smart devices',#11987,$,$); -#12010=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30','Fire alarm detection devices and control equipment',#11949,$,$); -#12011=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_01','Aspirating sampling pipes',#12010,$,$); -#12012=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_02','Aspirating sampling points',#12010,$,$); -#12013=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_03','Aspirating smoke detectors',#12010,$,$); -#12014=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_04','Aspirating smoke detector units',#12010,$,$); -#12015=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_13','Carbon monoxide and heat multi-sensor detectors',#12010,$,$); -#12016=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_15','Combined smoke and heat detectors',#12010,$,$); -#12017=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_20','Domestic smoke and carbon monoxide detectors',#12010,$,$); -#12018=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_22','Duct smoke detectors',#12010,$,$); -#12019=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_29','Fire alarm panels',#12010,$,$); -#12020=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_30','Fire alarm sounders',#12010,$,$); -#12021=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_31','Fire detection and alarm power supply equipment',#12010,$,$); -#12022=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_37','Heat alarms',#12010,$,$); -#12023=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_41','Interface panels',#12010,$,$); -#12024=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_50','Manual call points',#12010,$,$); -#12025=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_52','Mimic alarm panels',#12010,$,$); -#12026=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_55','Multisensor detectors',#12010,$,$); -#12027=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_59','Optical beam smoke detectors',#12010,$,$); -#12028=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_63','Point flame detectors',#12010,$,$); -#12029=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_64','Point heat detectors',#12010,$,$); -#12030=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_65','Point smoke detectors',#12010,$,$); -#12031=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_70','Radio-linked interface modules',#12010,$,$); -#12032=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_71','Remote indicators',#12010,$,$); -#12033=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_77','Short-circuit isolators',#12010,$,$); -#12034=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_80','Smoke alarms',#12010,$,$); -#12035=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_81','Smoke and carbon monoxide multi-sensor detectors',#12010,$,$); -#12036=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_82','Smoke and heat multi-sensor detectors',#12010,$,$); -#12037=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_94','Vibrating pillow pads',#12010,$,$); -#12038=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_95','Vibrating radio pager transmitters',#12010,$,$); -#12039=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_96','Vibrating radio pagers',#12010,$,$); -#12040=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_97','Visual alarm signal devices',#12010,$,$); -#12041=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_98','Voice alarm control panels',#12010,$,$); -#12042=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_32','Foreign object debris (FOD) detection equipment',#11949,$,$); -#12043=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_32_27','Electro-optical FOD detection equipment',#12042,$,$); -#12044=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_32_39','Hybrid FOD detection equipment',#12042,$,$); -#12045=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_32_70','Radar FOD detection equipment',#12042,$,$); -#12046=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42','Intruder detection and alarm devices and control equipment',#11949,$,$); -#12047=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_02','Acoustic detectors',#12046,$,$); -#12048=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_08','Beam interruption detectors',#12046,$,$); -#12049=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_11','Capacitive proximity detectors',#12046,$,$); -#12050=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_16','Combined passive infrared and microwave detectors',#12046,$,$); -#12051=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_17','Combined passive infrared and ultrasonic detectors',#12046,$,$); -#12052=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_22','Deliberately operated intruder alarm devices',#12046,$,$); -#12053=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_24','Door beam intruder detectors',#12046,$,$); -#12054=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_28','External intruder alarm sounders',#12046,$,$); -#12055=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_40','Internal electronic intruder alarm sounders',#12046,$,$); -#12056=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_41','Intruder alarm panels',#12046,$,$); -#12057=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_42','Intruder alarm remote keypads',#12046,$,$); -#12058=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_52','Microwave detectors',#12046,$,$); -#12059=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_60','Passive infrared detectors',#12046,$,$); -#12060=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_67','Protective switches',#12046,$,$); -#12061=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_77','Security fog devices',#12046,$,$); -#12062=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_92','Ultrasonic movement detectors',#12046,$,$); -#12063=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_94','Vibrating intruder alarm pagers',#12046,$,$); -#12064=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_95','Vibration detectors',#12046,$,$); -#12065=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_96','Volumetric capacitive detectors',#12046,$,$); -#12066=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_47','Lift control products',#11949,$,$); -#12067=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_47_41','Illuminated landing indicators',#12066,$,$); -#12068=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_47_43','Infrared landing controls',#12066,$,$); -#12069=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_47_46','Landing call stations',#12066,$,$); -#12070=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_50','Monitoring system control products',#11949,$,$); -#12071=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_50_02','Alarm interface units',#12070,$,$); -#12072=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_50_11','Camera control units',#12070,$,$); -#12073=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_50_14','Camera power supply units',#12070,$,$); -#12074=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_50_22','Demagnetizers',#12070,$,$); -#12075=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_50_55','Multiplexors',#12070,$,$); -#12076=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_50_60','Patch panels',#12070,$,$); -#12077=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_50_70','Radio frequency (RF) modulators',#12070,$,$); -#12078=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_50_94','Video input cards',#12070,$,$); -#12079=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_50_95','Video matrix switch controllers',#12070,$,$); -#12080=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_50_96','Video output cards',#12070,$,$); -#12081=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_60','Passport control products',#11949,$,$); -#12082=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_60_07','Biometric facial recognition products',#12081,$,$); -#12083=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_60_08','Biometric iris recognition products',#12081,$,$); -#12084=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_60_60','Passport readers',#12081,$,$); -#12085=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_75','Security screening products',#11949,$,$); -#12086=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_75_01','Advanced cabin baggage x-ray scanners',#12085,$,$); -#12087=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_75_06','Back scatter x-ray security scanners',#12085,$,$); -#12088=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_75_28','Explosive trace detection equipment',#12085,$,$); -#12089=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_75_47','Liquid explosive detection equipment',#12085,$,$); -#12090=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_75_52','Millimetre wave security scanners',#12085,$,$); -#12091=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_75_96','Walk-through metal detectors',#12085,$,$); -#12092=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90','Transmission control products',#11949,$,$); -#12093=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_16','Converter receivers',#12092,$,$); -#12094=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_17','Converter senders',#12092,$,$); -#12095=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_27','Encoders and decoders',#12092,$,$); -#12096=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_30','Fibre receivers',#12092,$,$); -#12097=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_31','Fibre transmitters',#12092,$,$); -#12098=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_41','Infrared receivers',#12092,$,$); -#12099=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_42','Infrared transmitters',#12092,$,$); -#12100=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_50','Microwave transmission beacons',#12092,$,$); -#12101=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_52','Microwave transmitters',#12092,$,$); -#12102=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_65','Protocol converters',#12092,$,$); -#12103=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_70','Radio interface units',#12092,$,$); -#12104=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_71','Radio receivers',#12092,$,$); -#12105=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_78','Sender modules',#12092,$,$); -#12106=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_88','Telemetry receivers',#12092,$,$); -#12107=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_89','Telemetry senders',#12092,$,$); -#12108=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_90','Telemetry transmitters',#12092,$,$); -#12109=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_91','Transmission modules',#12092,$,$); -#12110=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_94','Video receivers',#12092,$,$); -#12111=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_95','Video transmitters',#12092,$,$); -#12112=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94','Voice alarm and emergency voice communication equipment',#11949,$,$); -#12113=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_03','Ambient noise sensing controllers',#12112,$,$); -#12114=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_11','Cabinet voice alarm loudspeakers',#12112,$,$); -#12115=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_15','Ceiling mounted voice alarm loudspeakers',#12112,$,$); -#12116=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_19','Column voice alarm loudspeakers',#12112,$,$); -#12117=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_22','Disabled refuge master stations',#12112,$,$); -#12118=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_23','Disabled refuge outstations',#12112,$,$); -#12119=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_27','Emergency voice communication radio based equipment',#12112,$,$); -#12120=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_37','Horn voice alarm loudspeakers',#12112,$,$); -#12121=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_41','Input cards',#12112,$,$); -#12122=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_58','Output cards',#12112,$,$); -#12123=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_60','Paging microphones',#12112,$,$); -#12124=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_70','Radio microphones',#12112,$,$); -#12125=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_72','Radio public address interface boards',#12112,$,$); -#12126=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_74','Refuge point master stations',#12112,$,$); -#12127=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_76','Refuge point outstations',#12112,$,$); -#12128=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_93','Voice alarm control console',#12112,$,$); -#12129=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_94','Voice alarm controller microphones',#12112,$,$); -#12130=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_95','Voice alarm controllers',#12112,$,$); -#12131=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_96','Voice alarm emergency microphones',#12112,$,$); -#12132=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_97','Voice alarm power amplifiers',#12112,$,$); -#12133=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_98','Voice alarm power supply units',#12112,$,$); -#12134=IFCCLASSIFICATIONREFERENCE($,'Pr_80','Services general products',#4921,$,$); -#12135=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51','Measuring and metering products',#12134,$,$); -#12136=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_30','Measuring flumes',#12135,$,$); -#12137=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_30_20','Cutthroat flumes',#12136,$,$); -#12138=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_30_38','HS/H/HL flumes',#12136,$,$); -#12139=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_30_52','Montana flumes',#12136,$,$); -#12140=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_30_60','Palmer-Bowlus flumes',#12136,$,$); -#12141=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_30_61','Parshall flumes',#12136,$,$); -#12142=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_30_70','RBC flumes',#12136,$,$); -#12143=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_30_90','Trapezoidal flumes',#12136,$,$); -#12144=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_30_94','Venturi flumes',#12136,$,$); -#12145=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_46','Liquid flow meters',#12135,$,$); -#12146=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_46_15','Coriolis flowmeters',#12145,$,$); -#12147=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_46_27','Electromagnetic flow meters',#12145,$,$); -#12148=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_46_55','Multiphase flowmeters',#12145,$,$); -#12149=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_46_66','Primary flow differential pressure flowmeters',#12145,$,$); -#12150=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_46_73','Rotary piston flowmeters',#12145,$,$); -#12151=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_46_85','Swirl flowmeters',#12145,$,$); -#12152=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_46_88','Thermal mass flowmeters',#12145,$,$); -#12153=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_46_92','Ultrasonic flowmeters',#12145,$,$); -#12154=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51','Metering and test products',#12135,$,$); -#12155=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_04','Analogue metering equipment',#12154,$,$); -#12156=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_05','Ammeters',#12154,$,$); -#12157=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_06','Audio frequency induction loop field strength meters',#12154,$,$); -#12158=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_11','Call information logging equipment',#12154,$,$); -#12159=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_15','Corrosion monitors',#12154,$,$); -#12160=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_19','Current transformers',#12154,$,$); -#12161=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_21','Differential pressure flow meters',#12154,$,$); -#12162=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_22','Digital metering equipment',#12154,$,$); -#12163=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_23','Digital multifunction metering equipment',#12154,$,$); -#12164=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_28','Energy meters',#12154,$,$); -#12165=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_30','Frequency meters',#12154,$,$); -#12166=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_32','Fuel meters',#12154,$,$); -#12167=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_33','Gas meters',#12154,$,$); -#12168=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_37','Heat meters',#12154,$,$); -#12169=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_50','Mass flow meters',#12154,$,$); -#12170=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_57','Ohm meters',#12154,$,$); -#12171=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_58','Oil meters',#12154,$,$); -#12172=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_60','Phase meters',#12154,$,$); -#12173=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_62','Piezometers',#12154,$,$); -#12174=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_63','Power factor meters',#12154,$,$); -#12175=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_64','Portable gas monitors',#12154,$,$); -#12176=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_65','Portable leak monitors',#12154,$,$); -#12177=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_66','Portable moisture monitors',#12154,$,$); -#12178=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_67','Pressure meters',#12154,$,$); -#12179=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_80','Soil moisture monitors',#12154,$,$); -#12180=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_92','Ultrasonic flow meters',#12154,$,$); -#12181=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_93','Vapour meters',#12154,$,$); -#12182=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_94','Variable area flow meters',#12154,$,$); -#12183=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_95','Voltmeters',#12154,$,$); -#12184=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_96','Vortex flow meters',#12154,$,$); -#12185=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_97','Water meters',#12154,$,$); -#12186=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_98','Wattmeters',#12154,$,$); -#12187=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_70','Rail and road measuring products',#12135,$,$); -#12188=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_70_22','Digital straight edge gauges',#12187,$,$); -#12189=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_70_44','Junction work gauges',#12187,$,$); -#12190=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_70_64','Platform gauges',#12187,$,$); -#12191=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_70_85','Straight edge gauges',#12187,$,$); -#12192=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_70_88','Track geometry trolleys',#12187,$,$); -#12193=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_70_89','Track gauges',#12187,$,$); -#12194=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_70_90','Tunnel gauges',#12187,$,$); -#12195=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85','Structural instrumentation and monitoring products',#12135,$,$); -#12196=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_01','Accelerometers',#12195,$,$); -#12197=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_18','Crack gauges',#12195,$,$); -#12198=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_21','Data loggers',#12195,$,$); -#12199=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_27','Electrolevel sensor and microelectromechanical units',#12195,$,$); -#12200=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_28','Extensometers',#12195,$,$); -#12201=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_41','Inclinometers',#12195,$,$); -#12202=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_45','Linear movement detectors',#12195,$,$); -#12203=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_46','Liquid level gauges',#12195,$,$); -#12204=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_47','Load cells',#12195,$,$); -#12205=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_48','Logger box and readout box',#12195,$,$); -#12206=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_66','Precise levels',#12195,$,$); -#12207=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_84','Strain gauges',#12195,$,$); -#12208=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_87','Tape extensometers',#12195,$,$); -#12209=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_88','Tilt meters',#12195,$,$); -#12210=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_90','Total stations',#12195,$,$); -#12211=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_96','Weighbridge products',#12135,$,$); -#12212=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_96_00','Above ground weighbridges',#12211,$,$); -#12213=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_96_32','Fully inground weighbridges',#12211,$,$); -#12214=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_96_55','Multiple deck weighbridges',#12211,$,$); -#12215=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_96_71','Relocatable weighbridges',#12211,$,$); -#12216=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_96_77','Semi-pit weighbridges',#12211,$,$); -#12217=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_96_96','Wheel weigh pads',#12211,$,$); -#12218=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77','Services support and containment products',#12134,$,$); -#12219=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_23','Dock shelters',#12218,$,$); -#12220=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_23_30','Flap dock shelters',#12219,$,$); -#12221=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_23_31','Foam pad (cushion) dock seals',#12219,$,$); -#12222=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_23_42','Inflatable dock shelters',#12219,$,$); -#12223=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_23_70','Retractable dock shelters',#12219,$,$); -#12224=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_23_71','Rigid dock shelters',#12219,$,$); -#12225=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_23_72','Rigid dock shelters with inflatable seals',#12219,$,$); -#12226=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27','Equipment boards, racks and supports',#12218,$,$); -#12227=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_04','Audio-visual equipment racks',#12226,$,$); -#12228=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_07','Ballasted mounting frames for solar modules',#12226,$,$); -#12229=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_08','Battery shelving racks',#12226,$,$); -#12230=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_15','Channel supports',#12226,$,$); -#12231=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_31','Free standing mounting frames for solar modules',#12226,$,$); -#12232=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_33','Gauge mounting boards',#12226,$,$); -#12233=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_42','IT and telecommunications equipment racks',#12226,$,$); -#12234=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_51','Metal cladding solar module clamps',#12226,$,$); -#12235=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_53','Mounting plates',#12226,$,$); -#12236=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_54','Multi-service transit seals',#12226,$,$); -#12237=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_72','Roof anchors for solar modules',#12226,$,$); -#12238=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_73','Roof equipment supports',#12226,$,$); -#12239=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_80','Solar module support rails',#12226,$,$); -#12240=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_91','Turbine support structures',#12226,$,$); -#12241=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28','Equipment enclosures, cabinets, boxes and housings',#12218,$,$); -#12242=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_06','Balanced twisted-pair cabling patch panels',#12241,$,$); -#12243=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_07','Boundary boxes',#12241,$,$); -#12244=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_08','Cable junction boxes',#12241,$,$); -#12245=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_09','Cable termination boxes',#12241,$,$); -#12246=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_10','Camera brackets',#12241,$,$); -#12247=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_11','Camera housings',#12241,$,$); -#12248=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_13','Central battery enclosures',#12241,$,$); -#12249=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_16','Control circuit device enclosures',#12241,$,$); -#12250=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_21','Data equipment cabinets',#12241,$,$); -#12251=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_22','Display monitor housings',#12241,$,$); -#12252=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_24','Dry riser landing boxes',#12241,$,$); -#12253=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_26','Fibre joint enclosures',#12241,$,$); -#12254=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_27','Fibre optic patch panels',#12241,$,$); -#12255=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_28','Fire equipment cabinets',#12241,$,$); -#12256=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_29','Fire extinguisher cabinets',#12241,$,$); -#12257=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_30','Fire hose cabinets',#12241,$,$); -#12258=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_33','Generator enclosures',#12241,$,$); -#12259=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_46','Large fire hydrant surface boxes',#12241,$,$); -#12260=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_47','Loudspeaker protective cages',#12241,$,$); -#12261=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_48','Loudspeaker rear protective enclosures',#12241,$,$); -#12262=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_49','Low voltage switchgear enclosures',#12241,$,$); -#12263=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_52','Meter cabinets',#12241,$,$); -#12264=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_60','Padlock and key cabinets',#12241,$,$); -#12265=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_65','Power factor correction equipment enclosures',#12241,$,$); -#12266=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_70','Rack cabinets',#12241,$,$); -#12267=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_77','Switchgear enclosures',#12241,$,$); -#12268=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_78','Switchgear extension frames',#12241,$,$); -#12269=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_84','Surveillance camera brackets',#12241,$,$); -#12270=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_85','Surveillance camera housings',#12241,$,$); -#12271=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_86','Telephone enclosures',#12241,$,$); -#12272=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_88','Terminal air filter housings',#12241,$,$); -#12273=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_94','Valve boxes',#12241,$,$); -#12274=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_95','Video recorder cabinets',#12241,$,$); -#12275=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_96','Water fire extinguishing inlet boxes',#12241,$,$); -#12276=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_97','Water fire extinguishing surface boxes',#12241,$,$); -#12277=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_98','Weatherproof equipment enclosures',#12241,$,$); -#12278=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_46','Lift enclosures, access and supports',#12218,$,$); -#12279=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_46_32','Free standing self-supporting lift shafts',#12278,$,$); -#12280=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_46_46','Lift cars',#12278,$,$); -#12281=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48','Lighting columns, brackets and bollards',#12218,$,$); -#12282=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_01','Aluminium column luminaire brackets',#12281,$,$); -#12283=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_02','Aluminium lighting bollards',#12281,$,$); -#12284=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_03','Aluminium lighting columns',#12281,$,$); -#12285=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_04','Aluminium luminaire brackets',#12281,$,$); -#12286=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_15','Concrete lighting bollards',#12281,$,$); -#12287=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_16','Concrete lighting columns',#12281,$,$); -#12288=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_23','Double lighting columns',#12281,$,$); -#12289=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_55','Multiple light columns',#12281,$,$); -#12290=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_63','Plastics lighting bollards',#12281,$,$); -#12291=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_64','Plastics lighting columns',#12281,$,$); -#12292=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_78','Steel column luminaire brackets',#12281,$,$); -#12293=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_79','Steel lighting bollards',#12281,$,$); -#12294=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_80','Steel lighting columns',#12281,$,$); -#12295=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_81','Steel luminaire brackets',#12281,$,$); -#12296=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76','Services insulation and protection products',#12218,$,$); -#12297=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_03','Aluminium sheet insulation casing',#12296,$,$); -#12298=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_11','Calcium silicate preformed section and slab insulation',#12296,$,$); -#12299=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_12','Canvas insulation protection',#12296,$,$); -#12300=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_13','Carbon steel sheet insulation casing',#12296,$,$); -#12301=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_25','Ethylene propylene diene monomer (EPDM) rubber insulation',#12296,$,$); -#12302=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_29','Flexible elastomeric foam insulation',#12296,$,$); -#12303=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_34','Glass wool cloth insulation protection',#12296,$,$); -#12304=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_47','Loadbearing pipeline support insulation',#12296,$,$); -#12305=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_52','Mineral wool duct metal mesh faced mattress insulation',#12296,$,$); -#12306=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_53','Mineral wool duct slab insulation',#12296,$,$); -#12307=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_54','Mineral wool pipe section insulation',#12296,$,$); -#12308=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_58','Nitrile rubber insulation',#12296,$,$); -#12309=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_62','Phenolic foam insulation',#12296,$,$); -#12310=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_64','Polyisobutylene insulation protection',#12296,$,$); -#12311=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_65','Polyisocyanurate (PIR) insulation',#12296,$,$); -#12312=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_76','Self-adhesive insulation casing',#12296,$,$); -#12313=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_85','Stainless steel sheet insulation casing',#12296,$,$); -#12314=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_92','Unplasticized polyvinylchloride (PVC-U) sheet insulation casing',#12296,$,$); -#12315=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_94','Valve and flange insulation',#12296,$,$); -#12316=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_95','Valve and flange insulation casing',#12296,$,$); -#12317=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_94','Vibration isolation products',#12218,$,$); -#12318=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_94_15','Compression isolators',#12317,$,$); -#12319=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_94_30','Flexible vibration isolation hoses',#12317,$,$); -#12320=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_94_40','Inertia bases',#12317,$,$); -#12321=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_94_42','Isolation hangers',#12317,$,$); -#12322=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_94_50','Mat mountings',#12317,$,$); -#12323=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_94_60','Pad mountings',#12317,$,$); -#12324=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_94_65','Pneumatic isolation mounts',#12317,$,$); -#12325=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_94_74','Rubber bellows',#12317,$,$); -#12326=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_94_84','Spring isolators',#12317,$,$); -#12327=IFCCLASSIFICATIONREFERENCE($,'Pr_85','Process engineering products',#4921,$,$); -#12328=IFCCLASSIFICATIONREFERENCE($,'Pr_85_51','Milling products',#12327,$,$); -#12329=IFCCLASSIFICATIONREFERENCE($,'Pr_85_51_34','Grain milling products',#12328,$,$); -#12330=IFCCLASSIFICATIONREFERENCE($,'Pr_85_51_34_51','Millstones',#12329,$,$); -#12331=IFCCLASSIFICATIONREFERENCE($,'Pr_85_51_51','Mineral milling products',#12328,$,$); -#12332=IFCCLASSIFICATIONREFERENCE($,'Pr_85_51_87','Textile milling products',#12328,$,$); -#12333=IFCCLASSIFICATIONREFERENCE($,'Pr_85_51_88','Timber milling products',#12328,$,$); -#12334=IFCCLASSIFICATIONREFERENCE($,'Pr_85_73','Robotic products',#12327,$,$); -#12335=IFCCLASSIFICATIONREFERENCE($,'Pr_90','Soft facility management products',#4921,$,$); -#12336=IFCCLASSIFICATIONREFERENCE($,'Zz','CAD',#1,$,$); -#12337=IFCCLASSIFICATIONREFERENCE($,'Zz_10','Title sheet',#12336,$,$); -#12338=IFCCLASSIFICATIONREFERENCE($,'Zz_10_20','Drawing frame',#12337,$,$); -#12339=IFCCLASSIFICATIONREFERENCE($,'Zz_10_20_45','Logo',#12338,$,$); -#12340=IFCCLASSIFICATIONREFERENCE($,'Zz_10_20_95','Viewports',#12338,$,$); -#12341=IFCCLASSIFICATIONREFERENCE($,'Zz_10_40','Hold clouds and notation',#12337,$,$); -#12342=IFCCLASSIFICATIONREFERENCE($,'Zz_10_70','Revisions',#12337,$,$); -#12343=IFCCLASSIFICATIONREFERENCE($,'Zz_10_70_05','Annotation',#12342,$,$); -#12344=IFCCLASSIFICATIONREFERENCE($,'Zz_10_70_10','Blocks and cells',#12342,$,$); -#12345=IFCCLASSIFICATIONREFERENCE($,'Zz_10_70_20','Clouds and notations',#12342,$,$); -#12346=IFCCLASSIFICATIONREFERENCE($,'Zz_10_80','Status stamps',#12337,$,$); -#12347=IFCCLASSIFICATIONREFERENCE($,'Zz_20','Textual content',#12336,$,$); -#12348=IFCCLASSIFICATIONREFERENCE($,'Zz_20_10','Annotation',#12347,$,$); -#12349=IFCCLASSIFICATIONREFERENCE($,'Zz_20_10_40','Keynotes',#12348,$,$); -#12350=IFCCLASSIFICATIONREFERENCE($,'Zz_20_10_45','Labels',#12348,$,$); -#12351=IFCCLASSIFICATIONREFERENCE($,'Zz_20_10_50','Leaders',#12348,$,$); -#12352=IFCCLASSIFICATIONREFERENCE($,'Zz_20_10_55','Notes',#12348,$,$); -#12353=IFCCLASSIFICATIONREFERENCE($,'Zz_20_10_70','Reference',#12348,$,$); -#12354=IFCCLASSIFICATIONREFERENCE($,'Zz_20_10_85','Tags',#12348,$,$); -#12355=IFCCLASSIFICATIONREFERENCE($,'Zz_20_10_90','Text',#12348,$,$); -#12356=IFCCLASSIFICATIONREFERENCE($,'Zz_20_20','Dimensions',#12347,$,$); -#12357=IFCCLASSIFICATIONREFERENCE($,'Zz_20_30','General masking',#12347,$,$); -#12358=IFCCLASSIFICATIONREFERENCE($,'Zz_20_30_50','Masks',#12357,$,$); -#12359=IFCCLASSIFICATIONREFERENCE($,'Zz_20_30_95','Wipeouts',#12357,$,$); -#12360=IFCCLASSIFICATIONREFERENCE($,'Zz_20_40','Hatching',#12347,$,$); -#12361=IFCCLASSIFICATIONREFERENCE($,'Zz_20_40_05','Area fill',#12360,$,$); -#12362=IFCCLASSIFICATIONREFERENCE($,'Zz_20_40_35','Hatch boundaries',#12360,$,$); -#12363=IFCCLASSIFICATIONREFERENCE($,'Zz_20_40_60','Pattern',#12360,$,$); -#12364=IFCCLASSIFICATIONREFERENCE($,'Zz_20_40_80','Solid fill',#12360,$,$); -#12365=IFCCLASSIFICATIONREFERENCE($,'Zz_20_70','Redlining',#12347,$,$); -#12366=IFCCLASSIFICATIONREFERENCE($,'Zz_20_70_20','Comments',#12365,$,$); -#12367=IFCCLASSIFICATIONREFERENCE($,'Zz_20_80','Symbols',#12347,$,$); -#12368=IFCCLASSIFICATIONREFERENCE($,'Zz_20_80_10','Barscales',#12367,$,$); -#12369=IFCCLASSIFICATIONREFERENCE($,'Zz_20_80_15','Cross references',#12367,$,$); -#12370=IFCCLASSIFICATIONREFERENCE($,'Zz_20_80_40','Key plan',#12367,$,$); -#12371=IFCCLASSIFICATIONREFERENCE($,'Zz_20_80_50','Legends',#12367,$,$); -#12372=IFCCLASSIFICATIONREFERENCE($,'Zz_20_80_55','North point',#12367,$,$); -#12373=IFCCLASSIFICATIONREFERENCE($,'Zz_20_90','Title annotation',#12347,$,$); -#12374=IFCCLASSIFICATIONREFERENCE($,'Zz_30','Insertions',#12336,$,$); -#12375=IFCCLASSIFICATIONREFERENCE($,'Zz_30_20','Blocks and cells',#12374,$,$); -#12376=IFCCLASSIFICATIONREFERENCE($,'Zz_30_30','External references',#12374,$,$); -#12377=IFCCLASSIFICATIONREFERENCE($,'Zz_30_40','Images',#12374,$,$); -#12378=IFCCLASSIFICATIONREFERENCE($,'Zz_30_60','Objects',#12374,$,$); -#12379=IFCCLASSIFICATIONREFERENCE($,'Zz_30_90','Tables and schedules',#12374,$,$); -#12380=IFCCLASSIFICATIONREFERENCE($,'Zz_35','Setting out',#12336,$,$); -#12381=IFCCLASSIFICATIONREFERENCE($,'Zz_35_10','Alignments and super elevations',#12380,$,$); -#12382=IFCCLASSIFICATIONREFERENCE($,'Zz_35_10_40','Horizontal alignment',#12381,$,$); -#12383=IFCCLASSIFICATIONREFERENCE($,'Zz_35_10_80','Super elevation',#12381,$,$); -#12384=IFCCLASSIFICATIONREFERENCE($,'Zz_35_10_90','Vertical alignment',#12381,$,$); -#12385=IFCCLASSIFICATIONREFERENCE($,'Zz_35_20','Centrelines',#12380,$,$); -#12386=IFCCLASSIFICATIONREFERENCE($,'Zz_35_30','Geospatial control points',#12380,$,$); -#12387=IFCCLASSIFICATIONREFERENCE($,'Zz_35_40','Gridlines',#12380,$,$); -#12388=IFCCLASSIFICATIONREFERENCE($,'Zz_35_40_20','Ceiling grid',#12387,$,$); -#12389=IFCCLASSIFICATIONREFERENCE($,'Zz_35_40_80','Structural grid',#12387,$,$); -#12390=IFCCLASSIFICATIONREFERENCE($,'Zz_35_60','Points',#12380,$,$); -#12391=IFCCLASSIFICATIONREFERENCE($,'Zz_35_80','Survey control points',#12380,$,$); -#12392=IFCCLASSIFICATIONREFERENCE($,'Zz_35_80_55','OS bench mark',#12391,$,$); -#12393=IFCCLASSIFICATIONREFERENCE($,'Zz_35_80_60','OS trigonometrical station',#12391,$,$); -#12394=IFCCLASSIFICATIONREFERENCE($,'Zz_35_80_80','Site bench mark',#12391,$,$); -#12395=IFCCLASSIFICATIONREFERENCE($,'Zz_35_80_85','Site survey control station',#12391,$,$); -#12396=IFCCLASSIFICATIONREFERENCE($,'Zz_35_80_90','Temporary bench mark',#12391,$,$); -#12397=IFCCLASSIFICATIONREFERENCE($,'Zz_40','Topography',#12336,$,$); -#12398=IFCCLASSIFICATIONREFERENCE($,'Zz_40_15','Contours',#12397,$,$); -#12399=IFCCLASSIFICATIONREFERENCE($,'Zz_40_15_50','Major contours',#12398,$,$); -#12400=IFCCLASSIFICATIONREFERENCE($,'Zz_40_15_55','Minor contours',#12398,$,$); -#12401=IFCCLASSIFICATIONREFERENCE($,'Zz_40_20','Cuttings and embankment indicators',#12397,$,$); -#12402=IFCCLASSIFICATIONREFERENCE($,'Zz_40_50','Level indicators',#12397,$,$); -#12403=IFCCLASSIFICATIONREFERENCE($,'Zz_50','Zones and boundaries',#12336,$,$); -#12404=IFCCLASSIFICATIONREFERENCE($,'Zz_50_10','Boundaries',#12403,$,$); -#12405=IFCCLASSIFICATIONREFERENCE($,'Zz_50_10_10','Blue line boundary (BS 8541-2)',#12404,$,$); -#12406=IFCCLASSIFICATIONREFERENCE($,'Zz_50_10_70','Red line boundary (BS 8541-2)',#12404,$,$); -#12407=IFCCLASSIFICATIONREFERENCE($,'Zz_50_50','Lots',#12403,$,$); -#12408=IFCCLASSIFICATIONREFERENCE($,'Zz_50_60','Parcels',#12403,$,$); -#12409=IFCCLASSIFICATIONREFERENCE($,'Zz_50_90','Volumes',#12403,$,$); -#12410=IFCCLASSIFICATIONREFERENCE($,'Zz_50_95','Zones',#12403,$,$); -#12411=IFCCLASSIFICATIONREFERENCE($,'Zz_60','Drawing symbols',#12336,$,$); -#12412=IFCCLASSIFICATIONREFERENCE($,'Zz_60_20','Detail call ups',#12411,$,$); -#12413=IFCCLASSIFICATIONREFERENCE($,'Zz_60_30','Fall indicators',#12411,$,$); -#12414=IFCCLASSIFICATIONREFERENCE($,'Zz_60_40','Joint lines',#12411,$,$); -#12415=IFCCLASSIFICATIONREFERENCE($,'Zz_60_40_15','Construction joints',#12414,$,$); -#12416=IFCCLASSIFICATIONREFERENCE($,'Zz_60_40_20','Contraction joints',#12414,$,$); -#12417=IFCCLASSIFICATIONREFERENCE($,'Zz_60_40_30','Expansion joints',#12414,$,$); -#12418=IFCCLASSIFICATIONREFERENCE($,'Zz_60_45','Levels',#12411,$,$); -#12419=IFCCLASSIFICATIONREFERENCE($,'Zz_60_45_20','Datum',#12418,$,$); -#12420=IFCCLASSIFICATIONREFERENCE($,'Zz_60_45_60','Original ground level',#12418,$,$); -#12421=IFCCLASSIFICATIONREFERENCE($,'Zz_60_45_70','Regrade ground level',#12418,$,$); -#12422=IFCCLASSIFICATIONREFERENCE($,'Zz_60_50','Markers',#12411,$,$); -#12423=IFCCLASSIFICATIONREFERENCE($,'Zz_60_50_10','Break marks',#12422,$,$); -#12424=IFCCLASSIFICATIONREFERENCE($,'Zz_60_50_20','Callout marks',#12422,$,$); -#12425=IFCCLASSIFICATIONREFERENCE($,'Zz_60_50_30','Elevation marks',#12422,$,$); -#12426=IFCCLASSIFICATIONREFERENCE($,'Zz_60_50_60','Plan',#12422,$,$); -#12427=IFCCLASSIFICATIONREFERENCE($,'Zz_60_50_80','Section marks',#12422,$,$); -#12428=IFCCLASSIFICATIONREFERENCE($,'Zz_60_50_85','Span direction markers',#12422,$,$); -#12429=IFCCLASSIFICATIONREFERENCE($,'Zz_60_50_90','Void and opening markers',#12422,$,$); -#12430=IFCCLASSIFICATIONREFERENCE($,'Zz_60_55','Match lines',#12411,$,$); -#12431=IFCCLASSIFICATIONREFERENCE($,'Zz_70','Views',#12336,$,$); -#12432=IFCCLASSIFICATIONREFERENCE($,'Zz_70_05','3D views',#12431,$,$); -#12433=IFCCLASSIFICATIONREFERENCE($,'Zz_70_20','Details',#12431,$,$); -#12434=IFCCLASSIFICATIONREFERENCE($,'Zz_70_30','Elevations',#12431,$,$); -#12435=IFCCLASSIFICATIONREFERENCE($,'Zz_70_60','Plans',#12431,$,$); -#12436=IFCCLASSIFICATIONREFERENCE($,'Zz_70_80','Sections',#12431,$,$); -#12437=IFCCLASSIFICATIONREFERENCE($,'Zz_70_90','Visualisations',#12431,$,$); -#12438=IFCCLASSIFICATIONREFERENCE($,'Zz_80','Presentation',#12336,$,$); -#12439=IFCCLASSIFICATIONREFERENCE($,'Zz_80_30','Entourage',#12438,$,$); -#12440=IFCCLASSIFICATIONREFERENCE($,'Zz_80_45','Lines',#12438,$,$); -#12441=IFCCLASSIFICATIONREFERENCE($,'Zz_80_45_10','Fine',#12440,$,$); -#12442=IFCCLASSIFICATIONREFERENCE($,'Zz_80_45_20','Thin',#12440,$,$); -#12443=IFCCLASSIFICATIONREFERENCE($,'Zz_80_45_30','Light',#12440,$,$); -#12444=IFCCLASSIFICATIONREFERENCE($,'Zz_80_45_40','Medium',#12440,$,$); -#12445=IFCCLASSIFICATIONREFERENCE($,'Zz_80_45_50','Heavy',#12440,$,$); -#12446=IFCCLASSIFICATIONREFERENCE($,'Zz_80_45_60','Wide',#12440,$,$); -#12447=IFCCLASSIFICATIONREFERENCE($,'Zz_80_45_70','Extra-wide',#12440,$,$); -#12448=IFCCLASSIFICATIONREFERENCE($,'Zz_80_45_80','XX wide',#12440,$,$); -#12449=IFCCLASSIFICATIONREFERENCE($,'Zz_80_45_90','XXX wide',#12440,$,$); -#12450=IFCCLASSIFICATIONREFERENCE($,'Zz_80_60','People',#12438,$,$); -#12451=IFCCLASSIFICATIONREFERENCE($,'Zz_80_85','Trees and planting',#12438,$,$); -#12452=IFCCLASSIFICATIONREFERENCE($,'Zz_80_90','Vehicles',#12438,$,$); -#12453=IFCCLASSIFICATIONREFERENCE($,'Zz_85','Generic 3D',#12336,$,$); -#12454=IFCCLASSIFICATIONREFERENCE($,'Zz_85_05','3D solids',#12453,$,$); -#12455=IFCCLASSIFICATIONREFERENCE($,'Zz_85_05_60','Paths',#12454,$,$); -#12456=IFCCLASSIFICATIONREFERENCE($,'Zz_85_05_80','Solids',#12454,$,$); -#12457=IFCCLASSIFICATIONREFERENCE($,'Zz_85_05_85','Solid voids',#12454,$,$); -#12458=IFCCLASSIFICATIONREFERENCE($,'Zz_85_20','Concept',#12453,$,$); -#12459=IFCCLASSIFICATIONREFERENCE($,'Zz_85_20_20','Concept massing',#12458,$,$); -#12460=IFCCLASSIFICATIONREFERENCE($,'Zz_85_20_50','Mass group',#12458,$,$); -#12461=IFCCLASSIFICATIONREFERENCE($,'Zz_85_20_55','Mass slice',#12458,$,$); -#12462=IFCCLASSIFICATIONREFERENCE($,'Zz_90','Readme and plotting lines',#12336,$,$); -#12463=IFCCLASSIFICATIONREFERENCE($,'Zz_90_20','Construction lines',#12462,$,$); -#12464=IFCCLASSIFICATIONREFERENCE($,'Zz_90_30','External reference information',#12462,$,$); -#12465=IFCCLASSIFICATIONREFERENCE($,'Zz_90_70','Readme',#12462,$,$); +#1=IFCPROJECTLIBRARY($,$,'Uniclass 2015',$,$,$,$,$,$); +#2=IFCCLASSIFICATION('RIBA Enterprises Ltd','January 2020','2020-02-07','Uniclass 2015','Uniclass 2015 is a unified classification for the UK industry covering all construction sectors.','https://toolkit.thenbs.com/articles/classification',('_')); +#3=IFCRELASSOCIATESCLASSIFICATION('1P2XR4Nm9C_xuJOdxBr7V0',$,$,$,(#1),#2); +#4=IFCCLASSIFICATIONREFERENCE($,'Co','Complexes',#2,$,$); +#5=IFCCLASSIFICATIONREFERENCE($,'Co_20','Administrative, commercial and protective service complexes',#4,$,$); +#6=IFCCLASSIFICATIONREFERENCE($,'Co_20_10','Legislative complexes',#5,$,$); +#7=IFCCLASSIFICATIONREFERENCE($,'Co_20_10_60','Governmental complexes',#6,$,$); +#8=IFCCLASSIFICATIONREFERENCE($,'Co_20_15','Administrative complexes',#5,$,$); +#9=IFCCLASSIFICATIONREFERENCE($,'Co_20_15_08','Business parks',#8,$,$); +#10=IFCCLASSIFICATIONREFERENCE($,'Co_20_15_58','Office complexes',#8,$,$); +#11=IFCCLASSIFICATIONREFERENCE($,'Co_20_20','Secular representative complexes',#5,$,$); +#12=IFCCLASSIFICATIONREFERENCE($,'Co_20_20_15','Complexes for representatives of nation states abroad',#11,$,$); +#13=IFCCLASSIFICATIONREFERENCE($,'Co_20_20_40','Local government complexes',#11,$,$); +#14=IFCCLASSIFICATIONREFERENCE($,'Co_20_20_50','National government complexes',#11,$,$); +#15=IFCCLASSIFICATIONREFERENCE($,'Co_20_20_70','Regional government complexes',#11,$,$); +#16=IFCCLASSIFICATIONREFERENCE($,'Co_20_45','Motor vehicle maintenance and fuelling complexes',#5,$,$); +#17=IFCCLASSIFICATIONREFERENCE($,'Co_20_45_50','Motor vehicle fuelling and charging stations',#16,$,$); +#18=IFCCLASSIFICATIONREFERENCE($,'Co_20_45_54','Motor vehicle servicing complexes',#16,$,$); +#19=IFCCLASSIFICATIONREFERENCE($,'Co_20_50','Commercial complexes',#5,$,$); +#20=IFCCLASSIFICATIONREFERENCE($,'Co_20_50_05','Auction complexes',#19,$,$); +#21=IFCCLASSIFICATIONREFERENCE($,'Co_20_50_50','Market complexes',#19,$,$); +#22=IFCCLASSIFICATIONREFERENCE($,'Co_20_50_53','Mixed use complexes',#19,$,$); +#23=IFCCLASSIFICATIONREFERENCE($,'Co_20_50_60','Parade of shops',#19,$,$); +#24=IFCCLASSIFICATIONREFERENCE($,'Co_20_50_71','Retail parks',#19,$,$); +#25=IFCCLASSIFICATIONREFERENCE($,'Co_20_50_78','Shopping complexes',#19,$,$); +#26=IFCCLASSIFICATIONREFERENCE($,'Co_20_50_94','Vehicle sales complexes',#19,$,$); +#27=IFCCLASSIFICATIONREFERENCE($,'Co_20_55','Postal complexes',#5,$,$); +#28=IFCCLASSIFICATIONREFERENCE($,'Co_20_55_10','Postal communications complexes',#27,$,$); +#29=IFCCLASSIFICATIONREFERENCE($,'Co_20_60','Military complexes',#5,$,$); +#30=IFCCLASSIFICATIONREFERENCE($,'Co_20_60_02','Air force complexes',#29,$,$); +#31=IFCCLASSIFICATIONREFERENCE($,'Co_20_60_10','Army complexes',#29,$,$); +#32=IFCCLASSIFICATIONREFERENCE($,'Co_20_60_56','Navy complexes',#29,$,$); +#33=IFCCLASSIFICATIONREFERENCE($,'Co_20_65','Law enforcement complexes',#5,$,$); +#34=IFCCLASSIFICATIONREFERENCE($,'Co_20_65_56','Law enforcement agency complexes',#33,$,$); +#35=IFCCLASSIFICATIONREFERENCE($,'Co_20_70','Judicial complexes',#5,$,$); +#36=IFCCLASSIFICATIONREFERENCE($,'Co_20_70_18','Court complexes',#35,$,$); +#37=IFCCLASSIFICATIONREFERENCE($,'Co_20_70_65','Probation complexes',#35,$,$); +#38=IFCCLASSIFICATIONREFERENCE($,'Co_20_75','Detention complexes',#5,$,$); +#39=IFCCLASSIFICATIONREFERENCE($,'Co_20_75_42','Immigrant detention complexes',#38,$,$); +#40=IFCCLASSIFICATIONREFERENCE($,'Co_20_75_64','Prison complexes',#38,$,$); +#41=IFCCLASSIFICATIONREFERENCE($,'Co_20_75_71','Refugee detention complexes',#38,$,$); +#42=IFCCLASSIFICATIONREFERENCE($,'Co_20_80','Weapons training complexes',#5,$,$); +#43=IFCCLASSIFICATIONREFERENCE($,'Co_20_80_04','Artillery firing range complexes',#42,$,$); +#44=IFCCLASSIFICATIONREFERENCE($,'Co_20_80_80','Small arms firing range complexes',#42,$,$); +#45=IFCCLASSIFICATIONREFERENCE($,'Co_20_90','Incident support complexes',#5,$,$); +#46=IFCCLASSIFICATIONREFERENCE($,'Co_20_90_02','Air and sea rescue complexes',#45,$,$); +#47=IFCCLASSIFICATIONREFERENCE($,'Co_20_90_16','Coast guard stations',#45,$,$); +#48=IFCCLASSIFICATIONREFERENCE($,'Co_20_90_27','Fire brigade complexes',#45,$,$); +#49=IFCCLASSIFICATIONREFERENCE($,'Co_20_90_47','Life boat stations',#45,$,$); +#50=IFCCLASSIFICATIONREFERENCE($,'Co_20_90_53','Mountain rescue complexes',#45,$,$); +#51=IFCCLASSIFICATIONREFERENCE($,'Co_25','Cultural, educational, scientific and information complexes',#4,$,$); +#52=IFCCLASSIFICATIONREFERENCE($,'Co_25_05','Commemorative complexes',#51,$,$); +#53=IFCCLASSIFICATIONREFERENCE($,'Co_25_10','Educational complexes',#51,$,$); +#54=IFCCLASSIFICATIONREFERENCE($,'Co_25_10_32','Further education colleges',#53,$,$); +#55=IFCCLASSIFICATIONREFERENCE($,'Co_25_10_41','Infant schools',#53,$,$); +#56=IFCCLASSIFICATIONREFERENCE($,'Co_25_10_45','Kindergartens, nurseries and pre-schools',#53,$,$); +#57=IFCCLASSIFICATIONREFERENCE($,'Co_25_10_66','Primary schools',#53,$,$); +#58=IFCCLASSIFICATIONREFERENCE($,'Co_25_10_77','Secondary schools',#53,$,$); +#59=IFCCLASSIFICATIONREFERENCE($,'Co_25_10_88','Tertiary colleges',#53,$,$); +#60=IFCCLASSIFICATIONREFERENCE($,'Co_25_10_92','Universities',#53,$,$); +#61=IFCCLASSIFICATIONREFERENCE($,'Co_25_30','Scientific complexes',#51,$,$); +#62=IFCCLASSIFICATIONREFERENCE($,'Co_25_30_04','Astronomical observatory complexes',#61,$,$); +#63=IFCCLASSIFICATIONREFERENCE($,'Co_25_30_08','Botanic gardens',#61,$,$); +#64=IFCCLASSIFICATIONREFERENCE($,'Co_25_30_45','Laboratory complexes',#61,$,$); +#65=IFCCLASSIFICATIONREFERENCE($,'Co_25_30_70','Research complexes',#61,$,$); +#66=IFCCLASSIFICATIONREFERENCE($,'Co_25_50','Exhibition complexes',#51,$,$); +#67=IFCCLASSIFICATIONREFERENCE($,'Co_25_50_03','Art installations',#66,$,$); +#68=IFCCLASSIFICATIONREFERENCE($,'Co_25_50_33','Galleries',#66,$,$); +#69=IFCCLASSIFICATIONREFERENCE($,'Co_25_50_34','Gardens and arboretums',#66,$,$); +#70=IFCCLASSIFICATIONREFERENCE($,'Co_25_50_50','Memorial complexes',#66,$,$); +#71=IFCCLASSIFICATIONREFERENCE($,'Co_25_50_52','Monument complexes',#66,$,$); +#72=IFCCLASSIFICATIONREFERENCE($,'Co_25_50_54','Multi-purpose exhibition complexes',#66,$,$); +#73=IFCCLASSIFICATIONREFERENCE($,'Co_25_50_55','Museums',#66,$,$); +#74=IFCCLASSIFICATIONREFERENCE($,'Co_25_50_58','Open air museums',#66,$,$); +#75=IFCCLASSIFICATIONREFERENCE($,'Co_25_50_59','Open air sculpture parks',#66,$,$); +#76=IFCCLASSIFICATIONREFERENCE($,'Co_25_50_99','Zoos',#66,$,$); +#77=IFCCLASSIFICATIONREFERENCE($,'Co_25_70','Information complexes',#51,$,$); +#78=IFCCLASSIFICATIONREFERENCE($,'Co_25_70_16','Conference complexes',#77,$,$); +#79=IFCCLASSIFICATIONREFERENCE($,'Co_25_70_23','Document archives',#77,$,$); +#80=IFCCLASSIFICATIONREFERENCE($,'Co_25_70_30','Film archives',#77,$,$); +#81=IFCCLASSIFICATIONREFERENCE($,'Co_25_70_41','Information centres',#77,$,$); +#82=IFCCLASSIFICATIONREFERENCE($,'Co_25_70_47','Library complexes',#77,$,$); +#83=IFCCLASSIFICATIONREFERENCE($,'Co_25_90','Worship complexes',#51,$,$); +#84=IFCCLASSIFICATIONREFERENCE($,'Co_25_90_30','Faith worship complexes',#83,$,$); +#85=IFCCLASSIFICATIONREFERENCE($,'Co_30','Industrial complexes',#4,$,$); +#86=IFCCLASSIFICATIONREFERENCE($,'Co_30_10','Mineral extraction complexes',#85,$,$); +#87=IFCCLASSIFICATIONREFERENCE($,'Co_30_10_22','Deep mines',#86,$,$); +#88=IFCCLASSIFICATIONREFERENCE($,'Co_30_10_24','Drift mines',#86,$,$); +#89=IFCCLASSIFICATIONREFERENCE($,'Co_30_10_51','Methane hydrates extraction complexes',#86,$,$); +#90=IFCCLASSIFICATIONREFERENCE($,'Co_30_10_61','Open-cast mines',#86,$,$); +#91=IFCCLASSIFICATIONREFERENCE($,'Co_30_10_69','Quarries',#86,$,$); +#92=IFCCLASSIFICATIONREFERENCE($,'Co_30_10_77','Shale gas extraction complexes',#86,$,$); +#93=IFCCLASSIFICATIONREFERENCE($,'Co_30_10_78','Shale oil extraction complexes',#86,$,$); +#94=IFCCLASSIFICATIONREFERENCE($,'Co_30_20','Nuclear and chemical management complexes',#85,$,$); +#95=IFCCLASSIFICATIONREFERENCE($,'Co_30_20_80','Surface radioactive waste management complexes',#94,$,$); +#96=IFCCLASSIFICATIONREFERENCE($,'Co_30_20_95','Underground radioactive waste management complexes',#94,$,$); +#97=IFCCLASSIFICATIONREFERENCE($,'Co_30_30','Mineral processing complexes',#85,$,$); +#98=IFCCLASSIFICATIONREFERENCE($,'Co_30_30_30','Gas processing complexes',#97,$,$); +#99=IFCCLASSIFICATIONREFERENCE($,'Co_30_30_50','Oil processing complexes',#97,$,$); +#100=IFCCLASSIFICATIONREFERENCE($,'Co_30_30_55','Ore processing complexes',#97,$,$); +#101=IFCCLASSIFICATIONREFERENCE($,'Co_30_40','Animal and plant products processing complexes',#85,$,$); +#102=IFCCLASSIFICATIONREFERENCE($,'Co_30_40_01','Abattoirs',#101,$,$); +#103=IFCCLASSIFICATIONREFERENCE($,'Co_30_40_03','Animal product processing complexes',#101,$,$); +#104=IFCCLASSIFICATIONREFERENCE($,'Co_30_40_04','Arable crop processing complexes',#101,$,$); +#105=IFCCLASSIFICATIONREFERENCE($,'Co_30_40_06','Bakeries',#101,$,$); +#106=IFCCLASSIFICATIONREFERENCE($,'Co_30_40_08','Breweries',#101,$,$); +#107=IFCCLASSIFICATIONREFERENCE($,'Co_30_40_11','Canneries',#101,$,$); +#108=IFCCLASSIFICATIONREFERENCE($,'Co_30_40_22','Distilleries',#101,$,$); +#109=IFCCLASSIFICATIONREFERENCE($,'Co_30_40_30','Fish processing complexes',#101,$,$); +#110=IFCCLASSIFICATIONREFERENCE($,'Co_30_40_40','Horticultural crop processing complexes',#101,$,$); +#111=IFCCLASSIFICATIONREFERENCE($,'Co_30_40_55','Mills',#101,$,$); +#112=IFCCLASSIFICATIONREFERENCE($,'Co_30_40_60','Livestock processing complexes',#101,$,$); +#113=IFCCLASSIFICATIONREFERENCE($,'Co_30_40_90','Timber processing complexes',#101,$,$); +#114=IFCCLASSIFICATIONREFERENCE($,'Co_30_40_96','Wineries',#101,$,$); +#115=IFCCLASSIFICATIONREFERENCE($,'Co_30_50','Manufacturing complexes',#85,$,$); +#116=IFCCLASSIFICATIONREFERENCE($,'Co_30_50_37','Heavy manufacturing complexes',#115,$,$); +#117=IFCCLASSIFICATIONREFERENCE($,'Co_30_50_41','Industrial parks',#115,$,$); +#118=IFCCLASSIFICATIONREFERENCE($,'Co_30_50_47','Light manufacturing complexes',#115,$,$); +#119=IFCCLASSIFICATIONREFERENCE($,'Co_30_50_77','Ship and boat building yards',#115,$,$); +#120=IFCCLASSIFICATIONREFERENCE($,'Co_30_60','Cleaning and maintenance complexes',#85,$,$); +#121=IFCCLASSIFICATIONREFERENCE($,'Co_30_60_15','Commercial laundries',#120,$,$); +#122=IFCCLASSIFICATIONREFERENCE($,'Co_30_60_94','Vehicle cleaning complexes',#120,$,$); +#123=IFCCLASSIFICATIONREFERENCE($,'Co_30_80','Mechanical power generation complexes',#85,$,$); +#124=IFCCLASSIFICATIONREFERENCE($,'Co_30_80_10','Kinetic power generation complexes',#123,$,$); +#125=IFCCLASSIFICATIONREFERENCE($,'Co_30_85','Marine and water maintenance complexes',#85,$,$); +#126=IFCCLASSIFICATIONREFERENCE($,'Co_30_90','Warehousing and distribution complexes',#85,$,$); +#127=IFCCLASSIFICATIONREFERENCE($,'Co_32','Water and land management complexes',#4,$,$); +#128=IFCCLASSIFICATIONREFERENCE($,'Co_32_10','Agricultural and horticultural complexes',#127,$,$); +#129=IFCCLASSIFICATIONREFERENCE($,'Co_32_10_02','Arable farms',#128,$,$); +#130=IFCCLASSIFICATIONREFERENCE($,'Co_32_10_15','Crofts',#128,$,$); +#131=IFCCLASSIFICATIONREFERENCE($,'Co_32_10_28','Fish farms',#128,$,$); +#132=IFCCLASSIFICATIONREFERENCE($,'Co_32_10_30','Fish hatcheries',#128,$,$); +#133=IFCCLASSIFICATIONREFERENCE($,'Co_32_10_39','Horticultural nurseries',#128,$,$); +#134=IFCCLASSIFICATIONREFERENCE($,'Co_32_10_46','Livestock farms',#128,$,$); +#135=IFCCLASSIFICATIONREFERENCE($,'Co_32_10_50','Managed forests',#128,$,$); +#136=IFCCLASSIFICATIONREFERENCE($,'Co_32_10_58','Orchards',#128,$,$); +#137=IFCCLASSIFICATIONREFERENCE($,'Co_32_10_94','Vineyards',#128,$,$); +#138=IFCCLASSIFICATIONREFERENCE($,'Co_32_20','Designated areas',#127,$,$); +#139=IFCCLASSIFICATIONREFERENCE($,'Co_32_20_04','Areas of special architectural or historical interest',#138,$,$); +#140=IFCCLASSIFICATIONREFERENCE($,'Co_32_20_17','Commons',#138,$,$); +#141=IFCCLASSIFICATIONREFERENCE($,'Co_32_20_22','Designated archaeological sites',#138,$,$); +#142=IFCCLASSIFICATIONREFERENCE($,'Co_32_20_23','Designated nature reserves',#138,$,$); +#143=IFCCLASSIFICATIONREFERENCE($,'Co_32_20_57','National parks',#138,$,$); +#144=IFCCLASSIFICATIONREFERENCE($,'Co_32_50','Marine ways and waterway complexes',#127,$,$); +#145=IFCCLASSIFICATIONREFERENCE($,'Co_32_50_11','Causeways',#144,$,$); +#146=IFCCLASSIFICATIONREFERENCE($,'Co_32_50_48','Lighthouse complexes',#144,$,$); +#147=IFCCLASSIFICATIONREFERENCE($,'Co_32_50_94','Vessel berthing complexes',#144,$,$); +#148=IFCCLASSIFICATIONREFERENCE($,'Co_32_50_95','Vessel launching complexes',#144,$,$); +#149=IFCCLASSIFICATIONREFERENCE($,'Co_32_55','Marine and water protection complexes',#127,$,$); +#150=IFCCLASSIFICATIONREFERENCE($,'Co_32_55_20','Coastal protection complexes',#149,$,$); +#151=IFCCLASSIFICATIONREFERENCE($,'Co_32_55_27','Erosion protection complexes',#149,$,$); +#152=IFCCLASSIFICATIONREFERENCE($,'Co_32_55_30','Flood protection complexes',#149,$,$); +#153=IFCCLASSIFICATIONREFERENCE($,'Co_32_65','Natural areas',#127,$,$); +#154=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_04','Aquifers',#153,$,$); +#155=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_15','Cliffs',#153,$,$); +#156=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_16','Coastal zones',#153,$,$); +#157=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_22','Deserts',#153,$,$); +#158=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_27','Estuaries',#153,$,$); +#159=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_30','Forests',#153,$,$); +#160=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_38','Hills',#153,$,$); +#161=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_46','Lakes',#153,$,$); +#162=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_54','Mountains',#153,$,$); +#163=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_64','Ponds',#153,$,$); +#164=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_72','Rivers',#153,$,$); +#165=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_75','Saltmarshes',#153,$,$); +#166=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_79','Seasonal wetlands',#153,$,$); +#167=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_82','Springs',#153,$,$); +#168=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_85','Streams, brooks and burns',#153,$,$); +#169=IFCCLASSIFICATIONREFERENCE($,'Co_32_65_96','Woodlands',#153,$,$); +#170=IFCCLASSIFICATIONREFERENCE($,'Co_32_85','Water control and retaining complexes',#127,$,$); +#171=IFCCLASSIFICATIONREFERENCE($,'Co_32_85_50','Lock complexes',#170,$,$); +#172=IFCCLASSIFICATIONREFERENCE($,'Co_32_85_70','Reservoirs',#170,$,$); +#173=IFCCLASSIFICATIONREFERENCE($,'Co_32_85_88','Tidal barriers',#170,$,$); +#174=IFCCLASSIFICATIONREFERENCE($,'Co_32_85_96','Water control complexes',#170,$,$); +#175=IFCCLASSIFICATIONREFERENCE($,'Co_32_85_97','Water level and flow monitoring complexes',#170,$,$); +#176=IFCCLASSIFICATIONREFERENCE($,'Co_32_85_98','Water pumping complexes',#170,$,$); +#177=IFCCLASSIFICATIONREFERENCE($,'Co_35','Medical, health, welfare and sanitary complexes',#4,$,$); +#178=IFCCLASSIFICATIONREFERENCE($,'Co_35_10','Medical complexes',#177,$,$); +#179=IFCCLASSIFICATIONREFERENCE($,'Co_35_10_02','Air ambulance complexes',#178,$,$); +#180=IFCCLASSIFICATIONREFERENCE($,'Co_35_10_03','Ambulance complexes',#178,$,$); +#181=IFCCLASSIFICATIONREFERENCE($,'Co_35_10_15','Clinical complexes',#178,$,$); +#182=IFCCLASSIFICATIONREFERENCE($,'Co_35_10_37','Hospital complexes',#178,$,$); +#183=IFCCLASSIFICATIONREFERENCE($,'Co_35_50','Welfare complexes',#177,$,$); +#184=IFCCLASSIFICATIONREFERENCE($,'Co_35_50_30','Fitness and detox complexes',#183,$,$); +#185=IFCCLASSIFICATIONREFERENCE($,'Co_35_50_37','Hospices',#183,$,$); +#186=IFCCLASSIFICATIONREFERENCE($,'Co_35_50_58','Nursing homes',#183,$,$); +#187=IFCCLASSIFICATIONREFERENCE($,'Co_35_50_69','Quarantine stations',#183,$,$); +#188=IFCCLASSIFICATIONREFERENCE($,'Co_35_50_82','Spa complexes',#183,$,$); +#189=IFCCLASSIFICATIONREFERENCE($,'Co_35_50_90','Turkish baths',#183,$,$); +#190=IFCCLASSIFICATIONREFERENCE($,'Co_35_70','Funerary complexes',#177,$,$); +#191=IFCCLASSIFICATIONREFERENCE($,'Co_35_70_13','Cemeteries',#190,$,$); +#192=IFCCLASSIFICATIONREFERENCE($,'Co_35_70_16','Crematoriums',#190,$,$); +#193=IFCCLASSIFICATIONREFERENCE($,'Co_35_70_32','Funeral complexes',#190,$,$); +#194=IFCCLASSIFICATIONREFERENCE($,'Co_35_85','Animal complexes',#177,$,$); +#195=IFCCLASSIFICATIONREFERENCE($,'Co_35_85_02','Animal cage complexes',#194,$,$); +#196=IFCCLASSIFICATIONREFERENCE($,'Co_35_85_03','Animal pen complexes',#194,$,$); +#197=IFCCLASSIFICATIONREFERENCE($,'Co_35_85_04','Aquariums',#194,$,$); +#198=IFCCLASSIFICATIONREFERENCE($,'Co_35_85_05','Aviary complexes',#194,$,$); +#199=IFCCLASSIFICATIONREFERENCE($,'Co_35_85_45','Kennel complexes',#194,$,$); +#200=IFCCLASSIFICATIONREFERENCE($,'Co_35_85_85','Stable complexes',#194,$,$); +#201=IFCCLASSIFICATIONREFERENCE($,'Co_35_90','Animal medical, health, welfare, funerary and sanitary complexes',#177,$,$); +#202=IFCCLASSIFICATIONREFERENCE($,'Co_35_90_02','Animal funerary complexes',#201,$,$); +#203=IFCCLASSIFICATIONREFERENCE($,'Co_35_90_03','Animal quarantine stations',#201,$,$); +#204=IFCCLASSIFICATIONREFERENCE($,'Co_35_90_95','Veterinary hospitals',#201,$,$); +#205=IFCCLASSIFICATIONREFERENCE($,'Co_40','Recreational complexes',#4,$,$); +#206=IFCCLASSIFICATIONREFERENCE($,'Co_40_05','Amusement complexes',#205,$,$); +#207=IFCCLASSIFICATIONREFERENCE($,'Co_40_05_02','Amphitheatres',#206,$,$); +#208=IFCCLASSIFICATIONREFERENCE($,'Co_40_05_03','Amusement parks',#206,$,$); +#209=IFCCLASSIFICATIONREFERENCE($,'Co_40_05_30','Fairground complexes',#206,$,$); +#210=IFCCLASSIFICATIONREFERENCE($,'Co_40_05_63','Pleasure piers',#206,$,$); +#211=IFCCLASSIFICATIONREFERENCE($,'Co_40_05_89','Theme parks',#206,$,$); +#212=IFCCLASSIFICATIONREFERENCE($,'Co_40_35','Historic complexes',#205,$,$); +#213=IFCCLASSIFICATIONREFERENCE($,'Co_40_35_06','Battle sites',#212,$,$); +#214=IFCCLASSIFICATIONREFERENCE($,'Co_40_35_39','Historic sites',#212,$,$); +#215=IFCCLASSIFICATIONREFERENCE($,'Co_40_35_78','Sites of antiquity',#212,$,$); +#216=IFCCLASSIFICATIONREFERENCE($,'Co_40_35_94','Visible earthworks',#212,$,$); +#217=IFCCLASSIFICATIONREFERENCE($,'Co_40_60','Performing arts complexes',#205,$,$); +#218=IFCCLASSIFICATIONREFERENCE($,'Co_40_60_13','Cinema complexes',#217,$,$); +#219=IFCCLASSIFICATIONREFERENCE($,'Co_40_60_14','Circuses',#217,$,$); +#220=IFCCLASSIFICATIONREFERENCE($,'Co_40_60_16','Concert hall complexes',#217,$,$); +#221=IFCCLASSIFICATIONREFERENCE($,'Co_40_60_30','Film and television studio complexes',#217,$,$); +#222=IFCCLASSIFICATIONREFERENCE($,'Co_40_60_88','Theatre complexes',#217,$,$); +#223=IFCCLASSIFICATIONREFERENCE($,'Co_40_75','Social recreation complexes',#205,$,$); +#224=IFCCLASSIFICATIONREFERENCE($,'Co_40_75_15','Community centres',#223,$,$); +#225=IFCCLASSIFICATIONREFERENCE($,'Co_40_75_17','Country parks',#223,$,$); +#226=IFCCLASSIFICATIONREFERENCE($,'Co_40_75_68','Public parks',#223,$,$); +#227=IFCCLASSIFICATIONREFERENCE($,'Co_40_75_71','Recreation grounds',#223,$,$); +#228=IFCCLASSIFICATIONREFERENCE($,'Co_42','Sport and activity complexes',#4,$,$); +#229=IFCCLASSIFICATIONREFERENCE($,'Co_42_40','Indoor activity complexes',#228,$,$); +#230=IFCCLASSIFICATIONREFERENCE($,'Co_42_40_10','Indoor athletics stadiums',#229,$,$); +#231=IFCCLASSIFICATIONREFERENCE($,'Co_42_40_40','Indoor sports complexes',#229,$,$); +#232=IFCCLASSIFICATIONREFERENCE($,'Co_42_50','Outdoor activity complexes',#228,$,$); +#233=IFCCLASSIFICATIONREFERENCE($,'Co_42_50_10','Outdoor athletics stadiums',#232,$,$); +#234=IFCCLASSIFICATIONREFERENCE($,'Co_42_50_30','Golf courses',#232,$,$); +#235=IFCCLASSIFICATIONREFERENCE($,'Co_42_50_60','Outdoor sports complexes',#232,$,$); +#236=IFCCLASSIFICATIONREFERENCE($,'Co_42_50_70','Race horse gallops',#232,$,$); +#237=IFCCLASSIFICATIONREFERENCE($,'Co_42_50_95','Winter sport complexes',#232,$,$); +#238=IFCCLASSIFICATIONREFERENCE($,'Co_42_85','Swimming complexes',#228,$,$); +#239=IFCCLASSIFICATIONREFERENCE($,'Co_42_85_40','Indoor swimming pool complexes',#238,$,$); +#240=IFCCLASSIFICATIONREFERENCE($,'Co_42_85_60','Outdoor swimming pool complexes',#238,$,$); +#241=IFCCLASSIFICATIONREFERENCE($,'Co_42_85_96','Water parks',#238,$,$); +#242=IFCCLASSIFICATIONREFERENCE($,'Co_45','Residential complexes',#4,$,$); +#243=IFCCLASSIFICATIONREFERENCE($,'Co_45_10','Living complexes',#242,$,$); +#244=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_11','Camp sites',#243,$,$); +#245=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_12','Caravan parks',#243,$,$); +#246=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_15','Convents and monasteries',#243,$,$); +#247=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_27','Emergency camps',#243,$,$); +#248=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_35','Halls of residence',#243,$,$); +#249=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_36','High-rise residential complexes',#243,$,$); +#250=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_37','Hostels',#243,$,$); +#251=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_38','Hotels',#243,$,$); +#252=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_40','Houses in multiple occupation',#243,$,$); +#253=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_41','Housing estates',#243,$,$); +#254=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_51','Military camps',#243,$,$); +#255=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_54','Motels',#243,$,$); +#256=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_72','Religious retreats',#243,$,$); +#257=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_74','Residential properties',#243,$,$); +#258=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_78','Sheltered housing',#243,$,$); +#259=IFCCLASSIFICATIONREFERENCE($,'Co_45_10_98','Youth group camps',#243,$,$); +#260=IFCCLASSIFICATIONREFERENCE($,'Co_50','Waste disposal complexes',#4,$,$); +#261=IFCCLASSIFICATIONREFERENCE($,'Co_50_20','Wet waste collection and distribution complexes',#260,$,$); +#262=IFCCLASSIFICATIONREFERENCE($,'Co_50_20_10','Wastewater collection complexes',#261,$,$); +#263=IFCCLASSIFICATIONREFERENCE($,'Co_50_20_20','Wastewater collection networks',#261,$,$); +#264=IFCCLASSIFICATIONREFERENCE($,'Co_50_20_60','Drainage collection networks',#261,$,$); +#265=IFCCLASSIFICATIONREFERENCE($,'Co_50_40','Dry waste collection and distribution complexes',#260,$,$); +#266=IFCCLASSIFICATIONREFERENCE($,'Co_50_40_10','Dry waste collection complexes',#265,$,$); +#267=IFCCLASSIFICATIONREFERENCE($,'Co_50_40_50','Dry waste distribution complexes',#265,$,$); +#268=IFCCLASSIFICATIONREFERENCE($,'Co_50_60','Wet waste treatment and disposal complexes',#260,$,$); +#269=IFCCLASSIFICATIONREFERENCE($,'Co_50_60_40','Wastewater treatment complexes',#268,$,$); +#270=IFCCLASSIFICATIONREFERENCE($,'Co_50_60_80','Drainage disposal networks',#268,$,$); +#271=IFCCLASSIFICATIONREFERENCE($,'Co_50_80','Dry waste treatment and disposal complexes',#260,$,$); +#272=IFCCLASSIFICATIONREFERENCE($,'Co_50_80_40','Dry waste treatment complexes',#271,$,$); +#273=IFCCLASSIFICATIONREFERENCE($,'Co_50_80_70','Dry waste disposal complexes',#271,$,$); +#274=IFCCLASSIFICATIONREFERENCE($,'Co_55','Piped supply complexes',#4,$,$); +#275=IFCCLASSIFICATIONREFERENCE($,'Co_55_05','Gas extraction and treatment complexes',#274,$,$); +#276=IFCCLASSIFICATIONREFERENCE($,'Co_55_05_30','Gas extraction complexes',#275,$,$); +#277=IFCCLASSIFICATIONREFERENCE($,'Co_55_05_70','Gas treatment complexes',#275,$,$); +#278=IFCCLASSIFICATIONREFERENCE($,'Co_55_10','Liquid fuel extraction and treatment complexes',#274,$,$); +#279=IFCCLASSIFICATIONREFERENCE($,'Co_55_10_40','Oil extraction complexes',#278,$,$); +#280=IFCCLASSIFICATIONREFERENCE($,'Co_55_10_80','Oil treatment complexes',#278,$,$); +#281=IFCCLASSIFICATIONREFERENCE($,'Co_55_15','Water extraction and treatment complexes',#274,$,$); +#282=IFCCLASSIFICATIONREFERENCE($,'Co_55_15_10','Water extraction complexes',#281,$,$); +#283=IFCCLASSIFICATIONREFERENCE($,'Co_55_15_50','Water treatment complexes',#281,$,$); +#284=IFCCLASSIFICATIONREFERENCE($,'Co_55_20','Gas supply complexes',#274,$,$); +#285=IFCCLASSIFICATIONREFERENCE($,'Co_55_20_50','Gas distribution complexes',#284,$,$); +#286=IFCCLASSIFICATIONREFERENCE($,'Co_55_20_60','Gas distribution networks',#284,$,$); +#287=IFCCLASSIFICATIONREFERENCE($,'Co_55_50','Liquid fuel supply complexes',#274,$,$); +#288=IFCCLASSIFICATIONREFERENCE($,'Co_55_50_10','Liquid fuel distribution complexes',#287,$,$); +#289=IFCCLASSIFICATIONREFERENCE($,'Co_55_50_50','Liquid fuel distribution networks',#287,$,$); +#290=IFCCLASSIFICATIONREFERENCE($,'Co_55_70','Water supply complexes',#274,$,$); +#291=IFCCLASSIFICATIONREFERENCE($,'Co_55_70_20','Water distribution complexes',#290,$,$); +#292=IFCCLASSIFICATIONREFERENCE($,'Co_55_70_60','Water distribution networks',#290,$,$); +#293=IFCCLASSIFICATIONREFERENCE($,'Co_60','Heating, cooling and refrigeration complexes',#4,$,$); +#294=IFCCLASSIFICATIONREFERENCE($,'Co_60_10','Heating complexes',#293,$,$); +#295=IFCCLASSIFICATIONREFERENCE($,'Co_60_10_10','District heating complexes',#294,$,$); +#296=IFCCLASSIFICATIONREFERENCE($,'Co_60_40','Cooling complexes',#293,$,$); +#297=IFCCLASSIFICATIONREFERENCE($,'Co_60_40_10','District cooling complexes',#296,$,$); +#298=IFCCLASSIFICATIONREFERENCE($,'Co_65','Ventilation and air conditioning complexes',#4,$,$); +#299=IFCCLASSIFICATIONREFERENCE($,'Co_70','Electrical power generation and distribution complexes',#4,$,$); +#300=IFCCLASSIFICATIONREFERENCE($,'Co_70_10','Electrical power generation complexes',#299,$,$); +#301=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_08','Biomass power generation complexes',#300,$,$); +#302=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_16','Coal power generation complexes',#300,$,$); +#303=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_17','Combined heat and power generation complexes',#300,$,$); +#304=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_33','Gas power generation complexes',#300,$,$); +#305=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_34','Geothermal power generation complexes',#300,$,$); +#306=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_38','Hydroelectric power generation complexes',#300,$,$); +#307=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_57','Nuclear power generation complexes',#300,$,$); +#308=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_58','Offshore wind power generation complexes',#300,$,$); +#309=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_59','Oil-fired power generation complexes',#300,$,$); +#310=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_60','Onshore wind power generation complexes',#300,$,$); +#311=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_63','Photovoltaic power generation complexes',#300,$,$); +#312=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_81','Solar reflector power generation complexes',#300,$,$); +#313=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_88','Tidal power generation complexes',#300,$,$); +#314=IFCCLASSIFICATIONREFERENCE($,'Co_70_10_96','Wave power generation complexes',#300,$,$); +#315=IFCCLASSIFICATIONREFERENCE($,'Co_70_30','Electricity distribution complexes',#299,$,$); +#316=IFCCLASSIFICATIONREFERENCE($,'Co_70_30_35','High voltage electricity substation complexes',#315,$,$); +#317=IFCCLASSIFICATIONREFERENCE($,'Co_70_30_40','High voltage electricity networks',#315,$,$); +#318=IFCCLASSIFICATIONREFERENCE($,'Co_70_30_45','Low voltage electricity substation complexes',#315,$,$); +#319=IFCCLASSIFICATIONREFERENCE($,'Co_70_30_50','Low voltage electricity networks',#315,$,$); +#320=IFCCLASSIFICATIONREFERENCE($,'Co_75','Communications, security, safety and protection complexes',#4,$,$); +#321=IFCCLASSIFICATIONREFERENCE($,'Co_75_10','Communications complexes',#320,$,$); +#322=IFCCLASSIFICATIONREFERENCE($,'Co_75_10_10','Broadcast communications complexes',#321,$,$); +#323=IFCCLASSIFICATIONREFERENCE($,'Co_75_10_20','Broadcast communications networks',#321,$,$); +#324=IFCCLASSIFICATIONREFERENCE($,'Co_75_10_80','Telecommunications complexes',#321,$,$); +#325=IFCCLASSIFICATIONREFERENCE($,'Co_75_10_90','Telecommunications networks',#321,$,$); +#326=IFCCLASSIFICATIONREFERENCE($,'Co_80','Transport complexes',#4,$,$); +#327=IFCCLASSIFICATIONREFERENCE($,'Co_80_05','Aerospace complexes',#326,$,$); +#328=IFCCLASSIFICATIONREFERENCE($,'Co_80_05_02','Airports and airfields',#327,$,$); +#329=IFCCLASSIFICATIONREFERENCE($,'Co_80_05_38','Heliports',#327,$,$); +#330=IFCCLASSIFICATIONREFERENCE($,'Co_80_05_84','Spacecraft complexes',#327,$,$); +#331=IFCCLASSIFICATIONREFERENCE($,'Co_80_20','Cable transport complexes',#326,$,$); +#332=IFCCLASSIFICATIONREFERENCE($,'Co_80_20_02','Aerial tramway complexes',#331,$,$); +#333=IFCCLASSIFICATIONREFERENCE($,'Co_80_20_10','Cable railway complexes',#331,$,$); +#334=IFCCLASSIFICATIONREFERENCE($,'Co_80_20_13','Chairlift way complexes',#331,$,$); +#335=IFCCLASSIFICATIONREFERENCE($,'Co_80_20_32','Funicular railway complexes',#331,$,$); +#336=IFCCLASSIFICATIONREFERENCE($,'Co_80_20_34','Gondola lift way complexes',#331,$,$); +#337=IFCCLASSIFICATIONREFERENCE($,'Co_80_20_84','Surface lift way complexes',#331,$,$); +#338=IFCCLASSIFICATIONREFERENCE($,'Co_80_20_99','Zip line way complexes',#331,$,$); +#339=IFCCLASSIFICATIONREFERENCE($,'Co_80_35','Road complexes',#326,$,$); +#340=IFCCLASSIFICATIONREFERENCE($,'Co_80_35_10','Bus route networks',#339,$,$); +#341=IFCCLASSIFICATIONREFERENCE($,'Co_80_35_75','Road networks',#339,$,$); +#342=IFCCLASSIFICATIONREFERENCE($,'Co_80_50','Railway complexes',#326,$,$); +#343=IFCCLASSIFICATIONREFERENCE($,'Co_80_50_35','Heavy rail complexes',#342,$,$); +#344=IFCCLASSIFICATIONREFERENCE($,'Co_80_50_37','High-speed rail complexes',#342,$,$); +#345=IFCCLASSIFICATIONREFERENCE($,'Co_80_50_45','Light rail complexes',#342,$,$); +#346=IFCCLASSIFICATIONREFERENCE($,'Co_80_50_50','Magnetic levitation ways',#342,$,$); +#347=IFCCLASSIFICATIONREFERENCE($,'Co_80_50_53','Monorail complexes',#342,$,$); +#348=IFCCLASSIFICATIONREFERENCE($,'Co_80_50_56','Narrow-gauge rail complexes',#342,$,$); +#349=IFCCLASSIFICATIONREFERENCE($,'Co_80_50_69','Rack rail complexes',#342,$,$); +#350=IFCCLASSIFICATIONREFERENCE($,'Co_80_50_76','Road-based light rail complexes',#342,$,$); +#351=IFCCLASSIFICATIONREFERENCE($,'Co_80_70','Marine and waterways transport complexes',#326,$,$); +#352=IFCCLASSIFICATIONREFERENCE($,'Co_80_70_11','Cable ferry complexes',#351,$,$); +#353=IFCCLASSIFICATIONREFERENCE($,'Co_80_70_13','Canal complexes',#351,$,$); +#354=IFCCLASSIFICATIONREFERENCE($,'Co_80_70_17','Container ports',#351,$,$); +#355=IFCCLASSIFICATIONREFERENCE($,'Co_80_70_23','Dry bulk ports',#351,$,$); +#356=IFCCLASSIFICATIONREFERENCE($,'Co_80_70_30','Fishing ports',#351,$,$); +#357=IFCCLASSIFICATIONREFERENCE($,'Co_80_70_36','Harbours',#351,$,$); +#358=IFCCLASSIFICATIONREFERENCE($,'Co_80_70_47','Liquid bulk ports',#351,$,$); +#359=IFCCLASSIFICATIONREFERENCE($,'Co_80_70_72','Roll-on roll-off ports',#351,$,$); +#360=IFCCLASSIFICATIONREFERENCE($,'Co_80_70_77','Sea cruise ports',#351,$,$); +#361=IFCCLASSIFICATIONREFERENCE($,'Co_80_70_78','Sea ferry ports',#351,$,$); +#362=IFCCLASSIFICATIONREFERENCE($,'Co_80_70_96','Waterway ferry complexes',#351,$,$); +#363=IFCCLASSIFICATIONREFERENCE($,'Co_80_90','Transport interchange complexes',#326,$,$); +#364=IFCCLASSIFICATIONREFERENCE($,'Co_90','Circulation and storage complexes',#4,$,$); +#365=IFCCLASSIFICATIONREFERENCE($,'Co_90_50','Storage complexes',#364,$,$); +#366=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_03','Ambient food storage complexes',#365,$,$); +#367=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_04','Arms storage complexes',#365,$,$); +#368=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_15','Cold storage complexes',#365,$,$); +#369=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_16','Complexes for the storage of human remains',#365,$,$); +#370=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_24','Dry waste storage complexes',#365,$,$); +#371=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_34','Gas storage complexes',#365,$,$); +#372=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_45','Liquid fuel storage complexes',#365,$,$); +#373=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_51','Military arsenals',#365,$,$); +#374=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_52','Mineral storage complexes',#365,$,$); +#375=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_71','Refrigerated food storage complexes',#365,$,$); +#376=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_77','Secure storage complexes',#365,$,$); +#377=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_78','Self storage complexes',#365,$,$); +#378=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_80','Solid fuel storage complexes',#365,$,$); +#379=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_94','Warehouses',#365,$,$); +#380=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_95','Wastewater storage complexes',#365,$,$); +#381=IFCCLASSIFICATIONREFERENCE($,'Co_90_50_96','Water storage complexes',#365,$,$); +#382=IFCCLASSIFICATIONREFERENCE($,'Co_90_90','Plant and control complexes',#364,$,$); +#383=IFCCLASSIFICATIONREFERENCE($,'Co_90_90_50','Multiple services plant and equipment complexes',#382,$,$); +#384=IFCCLASSIFICATIONREFERENCE($,'En','Entities',#2,$,$); +#385=IFCCLASSIFICATIONREFERENCE($,'En_20','Administrative, commercial and protective service entities',#384,$,$); +#386=IFCCLASSIFICATIONREFERENCE($,'En_20_10','Legislative entities',#385,$,$); +#387=IFCCLASSIFICATIONREFERENCE($,'En_20_10_45','Governmental buildings',#386,$,$); +#388=IFCCLASSIFICATIONREFERENCE($,'En_20_15','Administrative office entities',#385,$,$); +#389=IFCCLASSIFICATIONREFERENCE($,'En_20_15_10','Multiple occupation office buildings',#388,$,$); +#390=IFCCLASSIFICATIONREFERENCE($,'En_20_15_70','Single occupation office buildings',#388,$,$); +#391=IFCCLASSIFICATIONREFERENCE($,'En_20_20','Secular representative entities',#385,$,$); +#392=IFCCLASSIFICATIONREFERENCE($,'En_20_20_10','Buildings for representatives of nation states abroad',#391,$,$); +#393=IFCCLASSIFICATIONREFERENCE($,'En_20_20_40','Local government buildings',#391,$,$); +#394=IFCCLASSIFICATIONREFERENCE($,'En_20_20_50','National government buildings',#391,$,$); +#395=IFCCLASSIFICATIONREFERENCE($,'En_20_20_70','Regional government buildings',#391,$,$); +#396=IFCCLASSIFICATIONREFERENCE($,'En_20_45','Motor vehicle maintenance and fuelling entities',#385,$,$); +#397=IFCCLASSIFICATIONREFERENCE($,'En_20_45_50','Motor vehicle fuelling and charging entities',#396,$,$); +#398=IFCCLASSIFICATIONREFERENCE($,'En_20_45_54','Motor vehicle servicing and repair entities',#396,$,$); +#399=IFCCLASSIFICATIONREFERENCE($,'En_20_50','Commercial entities',#385,$,$); +#400=IFCCLASSIFICATIONREFERENCE($,'En_20_50_05','Auction buildings',#399,$,$); +#401=IFCCLASSIFICATIONREFERENCE($,'En_20_50_22','Department stores',#399,$,$); +#402=IFCCLASSIFICATIONREFERENCE($,'En_20_50_29','Financial and professional services buildings',#399,$,$); +#403=IFCCLASSIFICATIONREFERENCE($,'En_20_50_50','Markets',#399,$,$); +#404=IFCCLASSIFICATIONREFERENCE($,'En_20_50_53','Mixed use buildings',#399,$,$); +#405=IFCCLASSIFICATIONREFERENCE($,'En_20_50_55','Motor vehicle sales entities',#399,$,$); +#406=IFCCLASSIFICATIONREFERENCE($,'En_20_50_80','Shop units',#399,$,$); +#407=IFCCLASSIFICATIONREFERENCE($,'En_20_50_85','Supermarkets',#399,$,$); +#408=IFCCLASSIFICATIONREFERENCE($,'En_20_50_97','Wholesale buildings',#399,$,$); +#409=IFCCLASSIFICATIONREFERENCE($,'En_20_55','Postal communications entities',#385,$,$); +#410=IFCCLASSIFICATIONREFERENCE($,'En_20_55_65','Post office buildings',#409,$,$); +#411=IFCCLASSIFICATIONREFERENCE($,'En_20_55_80','Sorting office buildings',#409,$,$); +#412=IFCCLASSIFICATIONREFERENCE($,'En_20_60','Military entities',#385,$,$); +#413=IFCCLASSIFICATIONREFERENCE($,'En_20_60_02','Air force buildings',#412,$,$); +#414=IFCCLASSIFICATIONREFERENCE($,'En_20_60_10','Army buildings',#412,$,$); +#415=IFCCLASSIFICATIONREFERENCE($,'En_20_60_56','Navy buildings',#412,$,$); +#416=IFCCLASSIFICATIONREFERENCE($,'En_20_65','Law enforcement operational entities',#385,$,$); +#417=IFCCLASSIFICATIONREFERENCE($,'En_20_65_09','Police buildings',#416,$,$); +#418=IFCCLASSIFICATIONREFERENCE($,'En_20_70','Judicial entities',#385,$,$); +#419=IFCCLASSIFICATIONREFERENCE($,'En_20_70_40','Law court buildings',#418,$,$); +#420=IFCCLASSIFICATIONREFERENCE($,'En_20_75','Detention entities',#385,$,$); +#421=IFCCLASSIFICATIONREFERENCE($,'En_20_75_10','Detention buildings',#420,$,$); +#422=IFCCLASSIFICATIONREFERENCE($,'En_20_80','Weapons training ranges',#385,$,$); +#423=IFCCLASSIFICATIONREFERENCE($,'En_20_80_29','Firing range buildings',#422,$,$); +#424=IFCCLASSIFICATIONREFERENCE($,'En_20_80_30','Exterior firing ranges',#422,$,$); +#425=IFCCLASSIFICATIONREFERENCE($,'En_20_85','Security entities',#385,$,$); +#426=IFCCLASSIFICATIONREFERENCE($,'En_20_85_15','Security control buildings',#425,$,$); +#427=IFCCLASSIFICATIONREFERENCE($,'En_20_85_30','Security fences',#425,$,$); +#428=IFCCLASSIFICATIONREFERENCE($,'En_20_90','Incident support entities',#385,$,$); +#429=IFCCLASSIFICATIONREFERENCE($,'En_20_90_10','Fire and rescue training buildings',#428,$,$); +#430=IFCCLASSIFICATIONREFERENCE($,'En_20_90_15','Fire station buildings',#428,$,$); +#431=IFCCLASSIFICATIONREFERENCE($,'En_25','Cultural, educational, scientific and information entities',#384,$,$); +#432=IFCCLASSIFICATIONREFERENCE($,'En_25_05','Commemoration entities',#431,$,$); +#433=IFCCLASSIFICATIONREFERENCE($,'En_25_05_35','Gardens of remembrance',#432,$,$); +#434=IFCCLASSIFICATIONREFERENCE($,'En_25_05_50','Memorials',#432,$,$); +#435=IFCCLASSIFICATIONREFERENCE($,'En_25_05_55','Monuments',#432,$,$); +#436=IFCCLASSIFICATIONREFERENCE($,'En_25_10','Educational entities',#431,$,$); +#437=IFCCLASSIFICATIONREFERENCE($,'En_25_10_10','Pre-school educational buildings',#436,$,$); +#438=IFCCLASSIFICATIONREFERENCE($,'En_25_10_20','Infant educational buildings',#436,$,$); +#439=IFCCLASSIFICATIONREFERENCE($,'En_25_10_30','Primary educational buildings',#436,$,$); +#440=IFCCLASSIFICATIONREFERENCE($,'En_25_10_40','Secondary educational buildings',#436,$,$); +#441=IFCCLASSIFICATIONREFERENCE($,'En_25_10_50','Pre-tertiary educational buildings',#436,$,$); +#442=IFCCLASSIFICATIONREFERENCE($,'En_25_10_60','Tertiary educational buildings',#436,$,$); +#443=IFCCLASSIFICATIONREFERENCE($,'En_25_10_70','Adult educational buildings',#436,$,$); +#444=IFCCLASSIFICATIONREFERENCE($,'En_25_30','Scientific and laboratory entities',#431,$,$); +#445=IFCCLASSIFICATIONREFERENCE($,'En_25_30_40','Laboratory buildings',#444,$,$); +#446=IFCCLASSIFICATIONREFERENCE($,'En_25_30_50','Meteorological stations',#444,$,$); +#447=IFCCLASSIFICATIONREFERENCE($,'En_25_30_60','Observatory buildings',#444,$,$); +#448=IFCCLASSIFICATIONREFERENCE($,'En_25_30_66','Observatory antennas',#444,$,$); +#449=IFCCLASSIFICATIONREFERENCE($,'En_25_30_70','Research buildings',#444,$,$); +#450=IFCCLASSIFICATIONREFERENCE($,'En_25_30_77','Seed banks',#444,$,$); +#451=IFCCLASSIFICATIONREFERENCE($,'En_25_30_90','Triangulation pillars',#444,$,$); +#452=IFCCLASSIFICATIONREFERENCE($,'En_25_50','Exhibition entities',#431,$,$); +#453=IFCCLASSIFICATIONREFERENCE($,'En_25_50_02','Art exhibition buildings',#452,$,$); +#454=IFCCLASSIFICATIONREFERENCE($,'En_25_50_04','Art installations',#452,$,$); +#455=IFCCLASSIFICATIONREFERENCE($,'En_25_50_15','Collection exhibition buildings',#452,$,$); +#456=IFCCLASSIFICATIONREFERENCE($,'En_25_50_29','Fauna exhibition buildings',#452,$,$); +#457=IFCCLASSIFICATIONREFERENCE($,'En_25_50_30','Fauna exhibition grounds',#452,$,$); +#458=IFCCLASSIFICATIONREFERENCE($,'En_25_50_31','Flora exhibition buildings',#452,$,$); +#459=IFCCLASSIFICATIONREFERENCE($,'En_25_50_32','Flora exhibition grounds',#452,$,$); +#460=IFCCLASSIFICATIONREFERENCE($,'En_25_50_54','Multipurpose exhibition buildings',#452,$,$); +#461=IFCCLASSIFICATIONREFERENCE($,'En_25_70','Information entities',#431,$,$); +#462=IFCCLASSIFICATIONREFERENCE($,'En_25_70_02','Archive buildings',#461,$,$); +#463=IFCCLASSIFICATIONREFERENCE($,'En_25_70_13','Conference buildings',#461,$,$); +#464=IFCCLASSIFICATIONREFERENCE($,'En_25_70_42','Information kiosks',#461,$,$); +#465=IFCCLASSIFICATIONREFERENCE($,'En_25_70_47','Library buildings',#461,$,$); +#466=IFCCLASSIFICATIONREFERENCE($,'En_25_90','Worship entities',#431,$,$); +#467=IFCCLASSIFICATIONREFERENCE($,'En_25_90_30','Faith worship buildings',#466,$,$); +#468=IFCCLASSIFICATIONREFERENCE($,'En_30','Industrial entities',#384,$,$); +#469=IFCCLASSIFICATIONREFERENCE($,'En_30_10','Mineral extraction entities',#468,$,$); +#470=IFCCLASSIFICATIONREFERENCE($,'En_30_10_57','Offshore oil and gas extraction platforms',#469,$,$); +#471=IFCCLASSIFICATIONREFERENCE($,'En_30_10_80','Spoil heaps',#469,$,$); +#472=IFCCLASSIFICATIONREFERENCE($,'En_30_10_85','Surface mining structures',#469,$,$); +#473=IFCCLASSIFICATIONREFERENCE($,'En_30_10_86','Surface mining cuttings',#469,$,$); +#474=IFCCLASSIFICATIONREFERENCE($,'En_30_10_90','Underground mining structures',#469,$,$); +#475=IFCCLASSIFICATIONREFERENCE($,'En_30_20','Nuclear and chemical management entities',#468,$,$); +#476=IFCCLASSIFICATIONREFERENCE($,'En_30_20_15','Radioactivity waste management control buildings',#475,$,$); +#477=IFCCLASSIFICATIONREFERENCE($,'En_30_20_30','High heat generating radioactive waste management tunnel',#475,$,$); +#478=IFCCLASSIFICATIONREFERENCE($,'En_30_20_35','High heat radioactive waste package transfer buildings',#475,$,$); +#479=IFCCLASSIFICATIONREFERENCE($,'En_30_20_45','Low heat radioactive waste package transfer buildings',#475,$,$); +#480=IFCCLASSIFICATIONREFERENCE($,'En_30_20_60','Low heat generating radioactive waste management vault',#475,$,$); +#481=IFCCLASSIFICATIONREFERENCE($,'En_30_20_70','Radioactivity decontamination buildings',#475,$,$); +#482=IFCCLASSIFICATIONREFERENCE($,'En_30_20_75','Radioactivity effluent management buildings',#475,$,$); +#483=IFCCLASSIFICATIONREFERENCE($,'En_30_30','Mineral processing entities',#468,$,$); +#484=IFCCLASSIFICATIONREFERENCE($,'En_30_30_33','Gas processing structures',#483,$,$); +#485=IFCCLASSIFICATIONREFERENCE($,'En_30_30_58','Oil processing structures',#483,$,$); +#486=IFCCLASSIFICATIONREFERENCE($,'En_30_30_59','Ore processing structures',#483,$,$); +#487=IFCCLASSIFICATIONREFERENCE($,'En_30_40','Animal and plant products processing entities',#468,$,$); +#488=IFCCLASSIFICATIONREFERENCE($,'En_30_40_01','Animal processing buildings',#487,$,$); +#489=IFCCLASSIFICATIONREFERENCE($,'En_30_40_20','Crop processing buildings',#487,$,$); +#490=IFCCLASSIFICATIONREFERENCE($,'En_30_40_30','Fish processing buildings',#487,$,$); +#491=IFCCLASSIFICATIONREFERENCE($,'En_30_40_40','Horticultural processing buildings',#487,$,$); +#492=IFCCLASSIFICATIONREFERENCE($,'En_30_40_90','Timber processing buildings',#487,$,$); +#493=IFCCLASSIFICATIONREFERENCE($,'En_30_50','Manufacturing entities',#468,$,$); +#494=IFCCLASSIFICATIONREFERENCE($,'En_30_50_15','Cranes',#493,$,$); +#495=IFCCLASSIFICATIONREFERENCE($,'En_30_50_50','Manufacturing buildings',#493,$,$); +#496=IFCCLASSIFICATIONREFERENCE($,'En_30_60','Cleaning and maintenance entities',#468,$,$); +#497=IFCCLASSIFICATIONREFERENCE($,'En_30_60_20','Decontamination laundry buildings',#496,$,$); +#498=IFCCLASSIFICATIONREFERENCE($,'En_30_60_40','Laundry buildings',#496,$,$); +#499=IFCCLASSIFICATIONREFERENCE($,'En_30_60_50','Maintenance buildings',#496,$,$); +#500=IFCCLASSIFICATIONREFERENCE($,'En_30_60_94','Vehicle cleaning buildings',#496,$,$); +#501=IFCCLASSIFICATIONREFERENCE($,'En_30_70','Process entities',#468,$,$); +#502=IFCCLASSIFICATIONREFERENCE($,'En_30_70_13','Chimney stacks',#501,$,$); +#503=IFCCLASSIFICATIONREFERENCE($,'En_30_70_15','Conveyors',#501,$,$); +#504=IFCCLASSIFICATIONREFERENCE($,'En_30_70_17','Cooling towers',#501,$,$); +#505=IFCCLASSIFICATIONREFERENCE($,'En_30_70_28','Equipment gantries',#501,$,$); +#506=IFCCLASSIFICATIONREFERENCE($,'En_30_80','Mechanical power generation',#468,$,$); +#507=IFCCLASSIFICATIONREFERENCE($,'En_30_80_96','Watermills',#506,$,$); +#508=IFCCLASSIFICATIONREFERENCE($,'En_30_80_97','Windmills',#506,$,$); +#509=IFCCLASSIFICATIONREFERENCE($,'En_30_85','Marine and water entities',#468,$,$); +#510=IFCCLASSIFICATIONREFERENCE($,'En_30_85_07','Boathouse buildings',#509,$,$); +#511=IFCCLASSIFICATIONREFERENCE($,'En_30_85_08','Boatyard buildings',#509,$,$); +#512=IFCCLASSIFICATIONREFERENCE($,'En_30_85_24','Dry docks',#509,$,$); +#513=IFCCLASSIFICATIONREFERENCE($,'En_30_85_80','Shipyard buildings',#509,$,$); +#514=IFCCLASSIFICATIONREFERENCE($,'En_30_90','Warehousing and distribution entities',#468,$,$); +#515=IFCCLASSIFICATIONREFERENCE($,'En_30_90_33','Goods warehousing buildings',#514,$,$); +#516=IFCCLASSIFICATIONREFERENCE($,'En_30_90_35','Goods distribution buildings',#514,$,$); +#517=IFCCLASSIFICATIONREFERENCE($,'En_32','Water and land management entities',#384,$,$); +#518=IFCCLASSIFICATIONREFERENCE($,'En_32_10','Agricultural and horticultural entities',#517,$,$); +#519=IFCCLASSIFICATIONREFERENCE($,'En_32_10_02','Arable buildings',#518,$,$); +#520=IFCCLASSIFICATIONREFERENCE($,'En_32_10_04','Arable land',#518,$,$); +#521=IFCCLASSIFICATIONREFERENCE($,'En_32_10_20','Coppices',#518,$,$); +#522=IFCCLASSIFICATIONREFERENCE($,'En_32_10_28','Fishing buildings',#518,$,$); +#523=IFCCLASSIFICATIONREFERENCE($,'En_32_10_29','Fishing cages',#518,$,$); +#524=IFCCLASSIFICATIONREFERENCE($,'En_32_10_30','Forestry buildings',#518,$,$); +#525=IFCCLASSIFICATIONREFERENCE($,'En_32_10_31','Forestry plantations',#518,$,$); +#526=IFCCLASSIFICATIONREFERENCE($,'En_32_10_39','Horticultural buildings',#518,$,$); +#527=IFCCLASSIFICATIONREFERENCE($,'En_32_10_40','Horticultural land',#518,$,$); +#528=IFCCLASSIFICATIONREFERENCE($,'En_32_10_46','Livestock buildings',#518,$,$); +#529=IFCCLASSIFICATIONREFERENCE($,'En_32_10_47','Livestock paddocks and fields',#518,$,$); +#530=IFCCLASSIFICATIONREFERENCE($,'En_32_10_93','Vineyard and winery buildings',#518,$,$); +#531=IFCCLASSIFICATIONREFERENCE($,'En_32_10_94','Vineyard plantations',#518,$,$); +#532=IFCCLASSIFICATIONREFERENCE($,'En_32_35','Grounds',#517,$,$); +#533=IFCCLASSIFICATIONREFERENCE($,'En_32_35_05','Arboretums',#532,$,$); +#534=IFCCLASSIFICATIONREFERENCE($,'En_32_35_12','Botanical gardens',#532,$,$); +#535=IFCCLASSIFICATIONREFERENCE($,'En_32_35_15','Community gardens',#532,$,$); +#536=IFCCLASSIFICATIONREFERENCE($,'En_32_35_33','Gardens',#532,$,$); +#537=IFCCLASSIFICATIONREFERENCE($,'En_32_35_36','Hard landscapes',#532,$,$); +#538=IFCCLASSIFICATIONREFERENCE($,'En_32_35_80','Soft landscapes',#532,$,$); +#539=IFCCLASSIFICATIONREFERENCE($,'En_32_40','Land managed entities',#517,$,$); +#540=IFCCLASSIFICATIONREFERENCE($,'En_32_40_20','Cuttings',#539,$,$); +#541=IFCCLASSIFICATIONREFERENCE($,'En_32_40_26','Embankments',#539,$,$); +#542=IFCCLASSIFICATIONREFERENCE($,'En_32_40_30','False cuttings',#539,$,$); +#543=IFCCLASSIFICATIONREFERENCE($,'En_32_40_90','Trenches',#539,$,$); +#544=IFCCLASSIFICATIONREFERENCE($,'En_32_50','Marine and water side entities',#517,$,$); +#545=IFCCLASSIFICATIONREFERENCE($,'En_32_50_20','Degaussing and acoustic ranges',#544,$,$); +#546=IFCCLASSIFICATIONREFERENCE($,'En_32_50_22','Dock buildings',#544,$,$); +#547=IFCCLASSIFICATIONREFERENCE($,'En_32_50_44','Jetties',#544,$,$); +#548=IFCCLASSIFICATIONREFERENCE($,'En_32_50_46','Landing stages',#544,$,$); +#549=IFCCLASSIFICATIONREFERENCE($,'En_32_50_58','Offshore anchorages',#544,$,$); +#550=IFCCLASSIFICATIONREFERENCE($,'En_32_50_63','Piers',#544,$,$); +#551=IFCCLASSIFICATIONREFERENCE($,'En_32_50_69','Quays',#544,$,$); +#552=IFCCLASSIFICATIONREFERENCE($,'En_32_50_98','Wharfs',#544,$,$); +#553=IFCCLASSIFICATIONREFERENCE($,'En_32_85','Water control and retaining entities',#517,$,$); +#554=IFCCLASSIFICATIONREFERENCE($,'En_32_85_06','Barrier beaches',#553,$,$); +#555=IFCCLASSIFICATIONREFERENCE($,'En_32_85_10','Breakwaters',#553,$,$); +#556=IFCCLASSIFICATIONREFERENCE($,'En_32_85_15','Control gates',#553,$,$); +#557=IFCCLASSIFICATIONREFERENCE($,'En_32_85_21','Dams',#553,$,$); +#558=IFCCLASSIFICATIONREFERENCE($,'En_32_85_23','Debris screens',#553,$,$); +#559=IFCCLASSIFICATIONREFERENCE($,'En_32_85_24','Dolphins',#553,$,$); +#560=IFCCLASSIFICATIONREFERENCE($,'En_32_85_25','Draw-off towers',#553,$,$); +#561=IFCCLASSIFICATIONREFERENCE($,'En_32_85_30','Flood prevention structures',#553,$,$); +#562=IFCCLASSIFICATIONREFERENCE($,'En_32_85_31','Flumes',#553,$,$); +#563=IFCCLASSIFICATIONREFERENCE($,'En_32_85_35','Groynes',#553,$,$); +#564=IFCCLASSIFICATIONREFERENCE($,'En_32_85_37','High ground',#553,$,$); +#565=IFCCLASSIFICATIONREFERENCE($,'En_32_85_45','Levees',#553,$,$); +#566=IFCCLASSIFICATIONREFERENCE($,'En_32_85_59','Outfalls',#553,$,$); +#567=IFCCLASSIFICATIONREFERENCE($,'En_32_85_72','Revetments',#553,$,$); +#568=IFCCLASSIFICATIONREFERENCE($,'En_32_85_77','Sea dikes',#553,$,$); +#569=IFCCLASSIFICATIONREFERENCE($,'En_32_85_80','Sluices',#553,$,$); +#570=IFCCLASSIFICATIONREFERENCE($,'En_32_85_82','Spillways',#553,$,$); +#571=IFCCLASSIFICATIONREFERENCE($,'En_32_85_84','Stilling basins',#553,$,$); +#572=IFCCLASSIFICATIONREFERENCE($,'En_32_85_96','Water retaining structures',#553,$,$); +#573=IFCCLASSIFICATIONREFERENCE($,'En_32_85_97','Weirs',#553,$,$); +#574=IFCCLASSIFICATIONREFERENCE($,'En_32_85_98','Wells',#553,$,$); +#575=IFCCLASSIFICATIONREFERENCE($,'En_32_95','Waterways',#517,$,$); +#576=IFCCLASSIFICATIONREFERENCE($,'En_32_95_14','Channels',#575,$,$); +#577=IFCCLASSIFICATIONREFERENCE($,'En_32_95_16','Complex culverts',#575,$,$); +#578=IFCCLASSIFICATIONREFERENCE($,'En_32_95_23','Ditches',#575,$,$); +#579=IFCCLASSIFICATIONREFERENCE($,'En_32_95_59','Open channels',#575,$,$); +#580=IFCCLASSIFICATIONREFERENCE($,'En_32_95_80','Simple culverts',#575,$,$); +#581=IFCCLASSIFICATIONREFERENCE($,'En_32_95_85','Surface water channels',#575,$,$); +#582=IFCCLASSIFICATIONREFERENCE($,'En_32_95_86','Swales',#575,$,$); +#583=IFCCLASSIFICATIONREFERENCE($,'En_35','Medical, health, welfare and sanitary entities',#384,$,$); +#584=IFCCLASSIFICATIONREFERENCE($,'En_35_10','Medical entities',#583,$,$); +#585=IFCCLASSIFICATIONREFERENCE($,'En_35_10_10','Medical buildings',#584,$,$); +#586=IFCCLASSIFICATIONREFERENCE($,'En_35_50','Welfare entities',#583,$,$); +#587=IFCCLASSIFICATIONREFERENCE($,'En_35_50_21','Day welfare buildings',#586,$,$); +#588=IFCCLASSIFICATIONREFERENCE($,'En_35_50_70','Residential welfare buildings',#586,$,$); +#589=IFCCLASSIFICATIONREFERENCE($,'En_35_50_94','Visitor welfare buildings',#586,$,$); +#590=IFCCLASSIFICATIONREFERENCE($,'En_35_70','Funerary entities',#583,$,$); +#591=IFCCLASSIFICATIONREFERENCE($,'En_35_70_06','Body storage buildings',#590,$,$); +#592=IFCCLASSIFICATIONREFERENCE($,'En_35_70_10','Burial buildings',#590,$,$); +#593=IFCCLASSIFICATIONREFERENCE($,'En_35_70_11','Burial grounds',#590,$,$); +#594=IFCCLASSIFICATIONREFERENCE($,'En_35_70_30','Funeral buildings',#590,$,$); +#595=IFCCLASSIFICATIONREFERENCE($,'En_35_70_60','Medical chimney stacks',#590,$,$); +#596=IFCCLASSIFICATIONREFERENCE($,'En_35_80','Sanitary entities',#583,$,$); +#597=IFCCLASSIFICATIONREFERENCE($,'En_35_80_10','Bathing buildings',#596,$,$); +#598=IFCCLASSIFICATIONREFERENCE($,'En_35_80_90','Toilet buildings',#596,$,$); +#599=IFCCLASSIFICATIONREFERENCE($,'En_35_85','Animal entities',#583,$,$); +#600=IFCCLASSIFICATIONREFERENCE($,'En_35_85_02','Animal cage buildings',#599,$,$); +#601=IFCCLASSIFICATIONREFERENCE($,'En_35_85_03','Animal pen buildings',#599,$,$); +#602=IFCCLASSIFICATIONREFERENCE($,'En_35_85_84','Stable buildings',#599,$,$); +#603=IFCCLASSIFICATIONREFERENCE($,'En_35_90','Animal medical, health, welfare and funerary entities',#583,$,$); +#604=IFCCLASSIFICATIONREFERENCE($,'En_35_90_10','Animal cemeteries',#603,$,$); +#605=IFCCLASSIFICATIONREFERENCE($,'En_35_90_30','Animal funerary buildings',#603,$,$); +#606=IFCCLASSIFICATIONREFERENCE($,'En_35_90_50','Animal medical buildings',#603,$,$); +#607=IFCCLASSIFICATIONREFERENCE($,'En_40','Recreational entities',#384,$,$); +#608=IFCCLASSIFICATIONREFERENCE($,'En_40_05','Amusement entities',#607,$,$); +#609=IFCCLASSIFICATIONREFERENCE($,'En_40_05_03','Amusement buildings',#608,$,$); +#610=IFCCLASSIFICATIONREFERENCE($,'En_40_05_13','Casinos',#608,$,$); +#611=IFCCLASSIFICATIONREFERENCE($,'En_40_05_42','Indoor fairgrounds',#608,$,$); +#612=IFCCLASSIFICATIONREFERENCE($,'En_40_05_60','Outdoor fairgrounds',#608,$,$); +#613=IFCCLASSIFICATIONREFERENCE($,'En_40_05_68','Public amenities',#608,$,$); +#614=IFCCLASSIFICATIONREFERENCE($,'En_40_20','Dining entities',#607,$,$); +#615=IFCCLASSIFICATIONREFERENCE($,'En_40_20_23','Dining buildings',#614,$,$); +#616=IFCCLASSIFICATIONREFERENCE($,'En_40_35','Historic entities',#607,$,$); +#617=IFCCLASSIFICATIONREFERENCE($,'En_40_35_10','Buildings of historic interest',#616,$,$); +#618=IFCCLASSIFICATIONREFERENCE($,'En_40_35_36','Historic buildings',#616,$,$); +#619=IFCCLASSIFICATIONREFERENCE($,'En_40_60','Performing arts entities',#607,$,$); +#620=IFCCLASSIFICATIONREFERENCE($,'En_40_60_10','Multiple performing arts buildings',#619,$,$); +#621=IFCCLASSIFICATIONREFERENCE($,'En_40_60_70','Single performing arts buildings',#619,$,$); +#622=IFCCLASSIFICATIONREFERENCE($,'En_40_75','Social recreation entities',#607,$,$); +#623=IFCCLASSIFICATIONREFERENCE($,'En_40_75_10','Multiple social recreation buildings',#622,$,$); +#624=IFCCLASSIFICATIONREFERENCE($,'En_40_75_15','Club houses',#622,$,$); +#625=IFCCLASSIFICATIONREFERENCE($,'En_40_75_70','Single social recreation buildings',#622,$,$); +#626=IFCCLASSIFICATIONREFERENCE($,'En_40_75_94','Visitor centres',#622,$,$); +#627=IFCCLASSIFICATIONREFERENCE($,'En_42','Sport and activity entities',#384,$,$); +#628=IFCCLASSIFICATIONREFERENCE($,'En_42_15','Courts, pitches and field sports entities',#627,$,$); +#629=IFCCLASSIFICATIONREFERENCE($,'En_42_15_06','Ball courts',#628,$,$); +#630=IFCCLASSIFICATIONREFERENCE($,'En_42_15_81','Sports grounds',#628,$,$); +#631=IFCCLASSIFICATIONREFERENCE($,'En_42_15_82','Sports pitches',#628,$,$); +#632=IFCCLASSIFICATIONREFERENCE($,'En_42_40','Indoor activity entities',#627,$,$); +#633=IFCCLASSIFICATIONREFERENCE($,'En_42_40_80','Sports buildings',#632,$,$); +#634=IFCCLASSIFICATIONREFERENCE($,'En_42_55','Outdoor activity entities',#627,$,$); +#635=IFCCLASSIFICATIONREFERENCE($,'En_42_55_01','Activity grounds',#634,$,$); +#636=IFCCLASSIFICATIONREFERENCE($,'En_42_55_34','Golf driving ranges',#634,$,$); +#637=IFCCLASSIFICATIONREFERENCE($,'En_42_85','Swimming entities',#627,$,$); +#638=IFCCLASSIFICATIONREFERENCE($,'En_42_85_60','Outdoor swimming pools',#637,$,$); +#639=IFCCLASSIFICATIONREFERENCE($,'En_42_85_83','Swimming pool buildings',#637,$,$); +#640=IFCCLASSIFICATIONREFERENCE($,'En_42_90','Water activity entities',#627,$,$); +#641=IFCCLASSIFICATIONREFERENCE($,'En_42_95','Winter sports entities',#627,$,$); +#642=IFCCLASSIFICATIONREFERENCE($,'En_42_95_40','Ice rink buildings',#641,$,$); +#643=IFCCLASSIFICATIONREFERENCE($,'En_42_95_80','Ski resort buildings',#641,$,$); +#644=IFCCLASSIFICATIONREFERENCE($,'En_45','Residential entities',#384,$,$); +#645=IFCCLASSIFICATIONREFERENCE($,'En_45_10','Residential buildings',#644,$,$); +#646=IFCCLASSIFICATIONREFERENCE($,'En_45_10_39','Houses',#645,$,$); +#647=IFCCLASSIFICATIONREFERENCE($,'En_45_10_47','Long-term residential buildings',#645,$,$); +#648=IFCCLASSIFICATIONREFERENCE($,'En_45_10_70','Short term residential buildings',#645,$,$); +#649=IFCCLASSIFICATIONREFERENCE($,'En_45_10_90','Temporary residential buildings',#645,$,$); +#650=IFCCLASSIFICATIONREFERENCE($,'En_50','Waste disposal entities',#384,$,$); +#651=IFCCLASSIFICATIONREFERENCE($,'En_50_10','Gas waste collection entities',#650,$,$); +#652=IFCCLASSIFICATIONREFERENCE($,'En_50_20','Wet waste collection entities',#650,$,$); +#653=IFCCLASSIFICATIONREFERENCE($,'En_50_20_10','Wet waste collection tanks',#652,$,$); +#654=IFCCLASSIFICATIONREFERENCE($,'En_50_30','Drainage and wastewater collection',#650,$,$); +#655=IFCCLASSIFICATIONREFERENCE($,'En_50_30_25','Drainage collection pipelines',#654,$,$); +#656=IFCCLASSIFICATIONREFERENCE($,'En_50_30_85','Surface water collection pipelines',#654,$,$); +#657=IFCCLASSIFICATIONREFERENCE($,'En_50_30_98','Wastewater collection pipelines',#654,$,$); +#658=IFCCLASSIFICATIONREFERENCE($,'En_50_30_99','Wastewater collection structures',#654,$,$); +#659=IFCCLASSIFICATIONREFERENCE($,'En_50_40','Dry waste collection and distribution',#650,$,$); +#660=IFCCLASSIFICATIONREFERENCE($,'En_50_40_10','Dry waste collection structures',#659,$,$); +#661=IFCCLASSIFICATIONREFERENCE($,'En_50_40_50','Dry waste distribution structures',#659,$,$); +#662=IFCCLASSIFICATIONREFERENCE($,'En_50_50','Gas waste storage, treatment and disposal',#650,$,$); +#663=IFCCLASSIFICATIONREFERENCE($,'En_50_60','Wet waste storage, treatment and disposal',#650,$,$); +#664=IFCCLASSIFICATIONREFERENCE($,'En_50_70','Drainage storage, treatment and disposal',#650,$,$); +#665=IFCCLASSIFICATIONREFERENCE($,'En_50_75','Wastewater storage, treatment and disposal',#650,$,$); +#666=IFCCLASSIFICATIONREFERENCE($,'En_50_75_15','Wastewater entities',#665,$,$); +#667=IFCCLASSIFICATIONREFERENCE($,'En_50_75_40','Wastewater treatment buildings',#665,$,$); +#668=IFCCLASSIFICATIONREFERENCE($,'En_50_75_45','Wastewater treatment entities',#665,$,$); +#669=IFCCLASSIFICATIONREFERENCE($,'En_50_75_70','Wastewater disposal buildings',#665,$,$); +#670=IFCCLASSIFICATIONREFERENCE($,'En_50_80','Dry waste treatment and disposal',#650,$,$); +#671=IFCCLASSIFICATIONREFERENCE($,'En_50_80_40','Dry waste treatment structures',#670,$,$); +#672=IFCCLASSIFICATIONREFERENCE($,'En_50_80_70','Dry waste disposal structures',#670,$,$); +#673=IFCCLASSIFICATIONREFERENCE($,'En_55','Piped supply entities',#384,$,$); +#674=IFCCLASSIFICATIONREFERENCE($,'En_55_05','Gas extraction, treatment and storage',#673,$,$); +#675=IFCCLASSIFICATIONREFERENCE($,'En_55_05_30','Gas extraction structures',#674,$,$); +#676=IFCCLASSIFICATIONREFERENCE($,'En_55_05_35','Gas extraction vessels',#674,$,$); +#677=IFCCLASSIFICATIONREFERENCE($,'En_55_05_38','Gas extraction pipelines',#674,$,$); +#678=IFCCLASSIFICATIONREFERENCE($,'En_55_05_70','Gas treatment buildings',#674,$,$); +#679=IFCCLASSIFICATIONREFERENCE($,'En_55_05_75','Gas treatment plant',#674,$,$); +#680=IFCCLASSIFICATIONREFERENCE($,'En_55_05_78','Gas treatment pipelines',#674,$,$); +#681=IFCCLASSIFICATIONREFERENCE($,'En_55_10','Liquid fuel extraction and treatment entities',#673,$,$); +#682=IFCCLASSIFICATIONREFERENCE($,'En_55_10_10','Oil extraction structures',#681,$,$); +#683=IFCCLASSIFICATIONREFERENCE($,'En_55_10_50','Fuel treatment buildings',#681,$,$); +#684=IFCCLASSIFICATIONREFERENCE($,'En_55_10_55','Fuel treatment tanks',#681,$,$); +#685=IFCCLASSIFICATIONREFERENCE($,'En_55_10_58','Fuel treatment pipelines',#681,$,$); +#686=IFCCLASSIFICATIONREFERENCE($,'En_55_15','Water extraction and treatment entities',#673,$,$); +#687=IFCCLASSIFICATIONREFERENCE($,'En_55_15_10','Water extraction buildings',#686,$,$); +#688=IFCCLASSIFICATIONREFERENCE($,'En_55_15_15','Water extraction tanks',#686,$,$); +#689=IFCCLASSIFICATIONREFERENCE($,'En_55_15_20','Water extraction pipelines',#686,$,$); +#690=IFCCLASSIFICATIONREFERENCE($,'En_55_15_50','Water treatment buildings',#686,$,$); +#691=IFCCLASSIFICATIONREFERENCE($,'En_55_15_55','Water treatment tanks',#686,$,$); +#692=IFCCLASSIFICATIONREFERENCE($,'En_55_20','Gas supply entities',#673,$,$); +#693=IFCCLASSIFICATIONREFERENCE($,'En_55_20_50','Gas distribution structures',#692,$,$); +#694=IFCCLASSIFICATIONREFERENCE($,'En_55_20_60','Gas distribution pipelines',#692,$,$); +#695=IFCCLASSIFICATIONREFERENCE($,'En_55_30','Fire extinguishing supply entities',#673,$,$); +#696=IFCCLASSIFICATIONREFERENCE($,'En_55_40','Steam supply entities',#673,$,$); +#697=IFCCLASSIFICATIONREFERENCE($,'En_55_50','Liquid fuel supply entities',#673,$,$); +#698=IFCCLASSIFICATIONREFERENCE($,'En_55_50_20','Fuel distribution pipelines',#697,$,$); +#699=IFCCLASSIFICATIONREFERENCE($,'En_55_50_45','Liquid fuel distribution buildings',#697,$,$); +#700=IFCCLASSIFICATIONREFERENCE($,'En_55_60','Process liquid supply entities',#673,$,$); +#701=IFCCLASSIFICATIONREFERENCE($,'En_55_70','Water supply entities',#673,$,$); +#702=IFCCLASSIFICATIONREFERENCE($,'En_55_70_10','Water distribution buildings',#701,$,$); +#703=IFCCLASSIFICATIONREFERENCE($,'En_55_70_18','Water distribution pipelines',#701,$,$); +#704=IFCCLASSIFICATIONREFERENCE($,'En_55_90','Piped solids supply entities',#673,$,$); +#705=IFCCLASSIFICATIONREFERENCE($,'En_60','Heating, cooling and refrigeration entities',#384,$,$); +#706=IFCCLASSIFICATIONREFERENCE($,'En_60_30','Rail and paving heating entities',#705,$,$); +#707=IFCCLASSIFICATIONREFERENCE($,'En_60_40','Space heating and cooling entities',#705,$,$); +#708=IFCCLASSIFICATIONREFERENCE($,'En_60_40_10','District heating buildings',#707,$,$); +#709=IFCCLASSIFICATIONREFERENCE($,'En_60_40_20','District heating pipelines',#707,$,$); +#710=IFCCLASSIFICATIONREFERENCE($,'En_60_40_50','District cooling buildings',#707,$,$); +#711=IFCCLASSIFICATIONREFERENCE($,'En_60_40_60','District cooling pipelines',#707,$,$); +#712=IFCCLASSIFICATIONREFERENCE($,'En_60_60','Refrigeration entities',#705,$,$); +#713=IFCCLASSIFICATIONREFERENCE($,'En_60_80','Drying entities',#705,$,$); +#714=IFCCLASSIFICATIONREFERENCE($,'En_65','Ventilation and air conditioning entities',#384,$,$); +#715=IFCCLASSIFICATIONREFERENCE($,'En_65_40','Ventilation entities',#714,$,$); +#716=IFCCLASSIFICATIONREFERENCE($,'En_65_40_80','Shaft and tunnel ventilation plant building',#715,$,$); +#717=IFCCLASSIFICATIONREFERENCE($,'En_65_80','Air conditioning entities',#714,$,$); +#718=IFCCLASSIFICATIONREFERENCE($,'En_70','Electrical power generation and distribution entities',#384,$,$); +#719=IFCCLASSIFICATIONREFERENCE($,'En_70_10','Electrical power generation entities',#718,$,$); +#720=IFCCLASSIFICATIONREFERENCE($,'En_70_10_10','Electrical power generation buildings',#719,$,$); +#721=IFCCLASSIFICATIONREFERENCE($,'En_70_10_80','Solar panel fields',#719,$,$); +#722=IFCCLASSIFICATIONREFERENCE($,'En_70_10_90','Wind turbines',#719,$,$); +#723=IFCCLASSIFICATIONREFERENCE($,'En_70_30','Electricity distribution and transmission entities',#718,$,$); +#724=IFCCLASSIFICATIONREFERENCE($,'En_70_30_18','Electricity transmission pylons and lines',#723,$,$); +#725=IFCCLASSIFICATIONREFERENCE($,'En_70_30_35','High-voltage electricity substations',#723,$,$); +#726=IFCCLASSIFICATIONREFERENCE($,'En_70_30_45','Low-voltage electricity substations',#723,$,$); +#727=IFCCLASSIFICATIONREFERENCE($,'En_70_30_90','Underground electricity transmission lines',#723,$,$); +#728=IFCCLASSIFICATIONREFERENCE($,'En_75','Communications, security, safety and protection entities',#384,$,$); +#729=IFCCLASSIFICATIONREFERENCE($,'En_75_10','Communication entities',#728,$,$); +#730=IFCCLASSIFICATIONREFERENCE($,'En_75_10_10','Broadcast communications buildings',#729,$,$); +#731=IFCCLASSIFICATIONREFERENCE($,'En_75_10_16','Broadcast communications masts and towers',#729,$,$); +#732=IFCCLASSIFICATIONREFERENCE($,'En_75_10_20','Data centres',#729,$,$); +#733=IFCCLASSIFICATIONREFERENCE($,'En_75_30','Signalling entities',#728,$,$); +#734=IFCCLASSIFICATIONREFERENCE($,'En_75_30_10','Peer-to-peer communications buildings',#733,$,$); +#735=IFCCLASSIFICATIONREFERENCE($,'En_75_30_18','Peer-to-peer communications networks',#733,$,$); +#736=IFCCLASSIFICATIONREFERENCE($,'En_75_30_78','Signalling control centres',#733,$,$); +#737=IFCCLASSIFICATIONREFERENCE($,'En_75_40','Security systems entities',#728,$,$); +#738=IFCCLASSIFICATIONREFERENCE($,'En_75_50','Safety and protection entities',#728,$,$); +#739=IFCCLASSIFICATIONREFERENCE($,'En_75_60','Environmental safety entities',#728,$,$); +#740=IFCCLASSIFICATIONREFERENCE($,'En_75_70','Control and management entities',#728,$,$); +#741=IFCCLASSIFICATIONREFERENCE($,'En_75_70_60','Operational control centres',#740,$,$); +#742=IFCCLASSIFICATIONREFERENCE($,'En_75_80','Protection entities',#728,$,$); +#743=IFCCLASSIFICATIONREFERENCE($,'En_80','Transport entities',#384,$,$); +#744=IFCCLASSIFICATIONREFERENCE($,'En_80_05','Aerospace entities',#743,$,$); +#745=IFCCLASSIFICATIONREFERENCE($,'En_80_05_01','Air traffic control towers',#744,$,$); +#746=IFCCLASSIFICATIONREFERENCE($,'En_80_05_02','Aircraft hangars',#744,$,$); +#747=IFCCLASSIFICATIONREFERENCE($,'En_80_05_60','Passenger terminal buildings',#744,$,$); +#748=IFCCLASSIFICATIONREFERENCE($,'En_80_20','Cable transport entities',#743,$,$); +#749=IFCCLASSIFICATIONREFERENCE($,'En_80_20_11','Cable car entities',#748,$,$); +#750=IFCCLASSIFICATIONREFERENCE($,'En_80_20_12','Cable car stations',#748,$,$); +#751=IFCCLASSIFICATIONREFERENCE($,'En_80_20_86','Suspended cableways',#748,$,$); +#752=IFCCLASSIFICATIONREFERENCE($,'En_80_35','Road entities',#743,$,$); +#753=IFCCLASSIFICATIONREFERENCE($,'En_80_35_01','Access roads',#752,$,$); +#754=IFCCLASSIFICATIONREFERENCE($,'En_80_35_05','Bus lanes',#752,$,$); +#755=IFCCLASSIFICATIONREFERENCE($,'En_80_35_07','Bus maintenance depots',#752,$,$); +#756=IFCCLASSIFICATIONREFERENCE($,'En_80_35_09','Bus and coach stations',#752,$,$); +#757=IFCCLASSIFICATIONREFERENCE($,'En_80_35_34','Guided bus lanes',#752,$,$); +#758=IFCCLASSIFICATIONREFERENCE($,'En_80_35_35','Highway maintenance depots',#752,$,$); +#759=IFCCLASSIFICATIONREFERENCE($,'En_80_35_38','Highway service stations',#752,$,$); +#760=IFCCLASSIFICATIONREFERENCE($,'En_80_35_56','Motorways',#752,$,$); +#761=IFCCLASSIFICATIONREFERENCE($,'En_80_35_67','Private roads',#752,$,$); +#762=IFCCLASSIFICATIONREFERENCE($,'En_80_35_74','Roads',#752,$,$); +#763=IFCCLASSIFICATIONREFERENCE($,'En_80_35_77','Service area buildings',#752,$,$); +#764=IFCCLASSIFICATIONREFERENCE($,'En_80_35_88','Tollgates',#752,$,$); +#765=IFCCLASSIFICATIONREFERENCE($,'En_80_35_89','Tracks',#752,$,$); +#766=IFCCLASSIFICATIONREFERENCE($,'En_80_35_90','Truck maintenance depots',#752,$,$); +#767=IFCCLASSIFICATIONREFERENCE($,'En_80_40','Pathways',#743,$,$); +#768=IFCCLASSIFICATIONREFERENCE($,'En_80_40_08','Bridleways',#767,$,$); +#769=IFCCLASSIFICATIONREFERENCE($,'En_80_40_10','Byways',#767,$,$); +#770=IFCCLASSIFICATIONREFERENCE($,'En_80_40_20','Cycle pathways',#767,$,$); +#771=IFCCLASSIFICATIONREFERENCE($,'En_80_40_30','Footpaths',#767,$,$); +#772=IFCCLASSIFICATIONREFERENCE($,'En_80_40_37','Hiking paths',#767,$,$); +#773=IFCCLASSIFICATIONREFERENCE($,'En_80_40_66','Promenades',#767,$,$); +#774=IFCCLASSIFICATIONREFERENCE($,'En_80_40_70','Rambler ways',#767,$,$); +#775=IFCCLASSIFICATIONREFERENCE($,'En_80_40_90','Trails',#767,$,$); +#776=IFCCLASSIFICATIONREFERENCE($,'En_80_45','Vehicle storage entities',#743,$,$); +#777=IFCCLASSIFICATIONREFERENCE($,'En_80_45_08','Bus parks',#776,$,$); +#778=IFCCLASSIFICATIONREFERENCE($,'En_80_45_11','Car garaging entities',#776,$,$); +#779=IFCCLASSIFICATIONREFERENCE($,'En_80_45_17','Coach parks',#776,$,$); +#780=IFCCLASSIFICATIONREFERENCE($,'En_80_45_55','Multi-storey vehicle parks',#776,$,$); +#781=IFCCLASSIFICATIONREFERENCE($,'En_80_45_85','Surface vehicle parks',#776,$,$); +#782=IFCCLASSIFICATIONREFERENCE($,'En_80_45_89','Truck parks',#776,$,$); +#783=IFCCLASSIFICATIONREFERENCE($,'En_80_45_92','Underground vehicle parks',#776,$,$); +#784=IFCCLASSIFICATIONREFERENCE($,'En_80_50','Railway entities',#743,$,$); +#785=IFCCLASSIFICATIONREFERENCE($,'En_80_50_53','Monorail entities',#784,$,$); +#786=IFCCLASSIFICATIONREFERENCE($,'En_80_50_58','Platforms',#784,$,$); +#787=IFCCLASSIFICATIONREFERENCE($,'En_80_50_60','Rack rail maintenance buildings',#784,$,$); +#788=IFCCLASSIFICATIONREFERENCE($,'En_80_50_62','Rack railways track entities',#784,$,$); +#789=IFCCLASSIFICATIONREFERENCE($,'En_80_50_64','Rail distribution depots',#784,$,$); +#790=IFCCLASSIFICATIONREFERENCE($,'En_80_50_68','Rail marshalling entities',#784,$,$); +#791=IFCCLASSIFICATIONREFERENCE($,'En_80_50_71','Railway corridors',#784,$,$); +#792=IFCCLASSIFICATIONREFERENCE($,'En_80_50_74','Railway stations',#784,$,$); +#793=IFCCLASSIFICATIONREFERENCE($,'En_80_50_76','Railway sidings',#784,$,$); +#794=IFCCLASSIFICATIONREFERENCE($,'En_80_50_78','Rolling stock depots',#784,$,$); +#795=IFCCLASSIFICATIONREFERENCE($,'En_80_50_83','Station buildings',#784,$,$); +#796=IFCCLASSIFICATIONREFERENCE($,'En_80_50_86','Track maintenance depots',#784,$,$); +#797=IFCCLASSIFICATIONREFERENCE($,'En_80_50_87','Trackside circuit breaker equipment buildings',#784,$,$); +#798=IFCCLASSIFICATIONREFERENCE($,'En_80_50_88','Train maintenance depots',#784,$,$); +#799=IFCCLASSIFICATIONREFERENCE($,'En_80_50_90','Tramways',#784,$,$); +#800=IFCCLASSIFICATIONREFERENCE($,'En_80_50_94','Underground railway stations',#784,$,$); +#801=IFCCLASSIFICATIONREFERENCE($,'En_80_50_95','Wagon decontamination buildings',#784,$,$); +#802=IFCCLASSIFICATIONREFERENCE($,'En_80_50_97','Wagon maintenance buildings',#784,$,$); +#803=IFCCLASSIFICATIONREFERENCE($,'En_80_70','Marine and waterways transport entities',#743,$,$); +#804=IFCCLASSIFICATIONREFERENCE($,'En_80_70_06','Barge loading terminals',#803,$,$); +#805=IFCCLASSIFICATIONREFERENCE($,'En_80_70_11','Canal channels',#803,$,$); +#806=IFCCLASSIFICATIONREFERENCE($,'En_80_70_15','Canal locks',#803,$,$); +#807=IFCCLASSIFICATIONREFERENCE($,'En_80_70_46','Lake passenger terminals',#803,$,$); +#808=IFCCLASSIFICATIONREFERENCE($,'En_80_70_50','Marinas',#803,$,$); +#809=IFCCLASSIFICATIONREFERENCE($,'En_80_70_71','River passenger terminals',#803,$,$); +#810=IFCCLASSIFICATIONREFERENCE($,'En_80_90','Transport hub entities',#743,$,$); +#811=IFCCLASSIFICATIONREFERENCE($,'En_80_90_30','Freight depots',#810,$,$); +#812=IFCCLASSIFICATIONREFERENCE($,'En_80_90_66','Rail freight entities',#810,$,$); +#813=IFCCLASSIFICATIONREFERENCE($,'En_80_90_73','Road freight depots',#810,$,$); +#814=IFCCLASSIFICATIONREFERENCE($,'En_80_90_90','Transport interchanges',#810,$,$); +#815=IFCCLASSIFICATIONREFERENCE($,'En_80_94','Bridges',#743,$,$); +#816=IFCCLASSIFICATIONREFERENCE($,'En_80_94_30','Fixed bridges',#815,$,$); +#817=IFCCLASSIFICATIONREFERENCE($,'En_80_94_50','Moveable bridges',#815,$,$); +#818=IFCCLASSIFICATIONREFERENCE($,'En_80_96','Tunnels and shafts',#743,$,$); +#819=IFCCLASSIFICATIONREFERENCE($,'En_80_96_20','Drift tunnels',#818,$,$); +#820=IFCCLASSIFICATIONREFERENCE($,'En_80_96_46','Lined drift tunnels',#818,$,$); +#821=IFCCLASSIFICATIONREFERENCE($,'En_80_96_49','Lined tunnels',#818,$,$); +#822=IFCCLASSIFICATIONREFERENCE($,'En_80_96_80','Shafts',#818,$,$); +#823=IFCCLASSIFICATIONREFERENCE($,'En_80_96_90','Tunnels',#818,$,$); +#824=IFCCLASSIFICATIONREFERENCE($,'En_80_96_91','Tunnel portals',#818,$,$); +#825=IFCCLASSIFICATIONREFERENCE($,'En_80_96_92','Underpasses',#818,$,$); +#826=IFCCLASSIFICATIONREFERENCE($,'En_90','Circulation and storage entities',#384,$,$); +#827=IFCCLASSIFICATIONREFERENCE($,'En_90_10','Circulation entities',#826,$,$); +#828=IFCCLASSIFICATIONREFERENCE($,'En_90_10_02','Access stairways and walkways',#827,$,$); +#829=IFCCLASSIFICATIONREFERENCE($,'En_90_10_62','Pedestrianized areas',#827,$,$); +#830=IFCCLASSIFICATIONREFERENCE($,'En_90_10_77','External service areas',#827,$,$); +#831=IFCCLASSIFICATIONREFERENCE($,'En_90_50','Storage entities',#826,$,$); +#832=IFCCLASSIFICATIONREFERENCE($,'En_90_50_02','Agricultural storage buildings',#831,$,$); +#833=IFCCLASSIFICATIONREFERENCE($,'En_90_50_03','Agricultural storage silos',#831,$,$); +#834=IFCCLASSIFICATIONREFERENCE($,'En_90_50_10','Dry waste storage structures',#831,$,$); +#835=IFCCLASSIFICATIONREFERENCE($,'En_90_50_11','Dry waste storage yards',#831,$,$); +#836=IFCCLASSIFICATIONREFERENCE($,'En_90_50_28','Explosives stores',#831,$,$); +#837=IFCCLASSIFICATIONREFERENCE($,'En_90_50_50','Manufacturing tanks and silos',#831,$,$); +#838=IFCCLASSIFICATIONREFERENCE($,'En_90_50_53','Mineral storage silos',#831,$,$); +#839=IFCCLASSIFICATIONREFERENCE($,'En_90_50_55','Motor vehicle storage entities',#831,$,$); +#840=IFCCLASSIFICATIONREFERENCE($,'En_90_50_58','Oil and gas storage tanks',#831,$,$); +#841=IFCCLASSIFICATIONREFERENCE($,'En_90_50_68','Refrigerated container storage entities',#831,$,$); +#842=IFCCLASSIFICATIONREFERENCE($,'En_90_50_70','Storage buildings',#831,$,$); +#843=IFCCLASSIFICATIONREFERENCE($,'En_90_50_96','Wastewater storage structures',#831,$,$); +#844=IFCCLASSIFICATIONREFERENCE($,'En_90_90','Plant and control entities',#826,$,$); +#845=IFCCLASSIFICATIONREFERENCE($,'En_90_90_09','Buried services routes',#844,$,$); +#846=IFCCLASSIFICATIONREFERENCE($,'En_90_90_11','Cable routes',#844,$,$); +#847=IFCCLASSIFICATIONREFERENCE($,'En_90_90_33','Gauge houses',#844,$,$); +#848=IFCCLASSIFICATIONREFERENCE($,'En_90_90_35','Gauging station buildings',#844,$,$); +#849=IFCCLASSIFICATIONREFERENCE($,'En_90_90_50','Mechanical services buildings',#844,$,$); +#850=IFCCLASSIFICATIONREFERENCE($,'En_90_90_64','Plant and equipment buildings',#844,$,$); +#851=IFCCLASSIFICATIONREFERENCE($,'En_90_90_68','Pump houses',#844,$,$); +#852=IFCCLASSIFICATIONREFERENCE($,'Ac','Activities',#2,$,$); +#853=IFCCLASSIFICATIONREFERENCE($,'Ac_05','Project management activities',#852,$,$); +#854=IFCCLASSIFICATIONREFERENCE($,'Ac_05_00','Strategy stage activities',#853,$,$); +#855=IFCCLASSIFICATIONREFERENCE($,'Ac_05_00_10','Business case development',#854,$,$); +#856=IFCCLASSIFICATIONREFERENCE($,'Ac_05_00_80','Strategic brief preparation',#854,$,$); +#857=IFCCLASSIFICATIONREFERENCE($,'Ac_05_00_82','Strategic brief submission',#854,$,$); +#858=IFCCLASSIFICATIONREFERENCE($,'Ac_05_10','Brief stage activities',#853,$,$); +#859=IFCCLASSIFICATIONREFERENCE($,'Ac_05_10_15','Cost estimate preparation',#858,$,$); +#860=IFCCLASSIFICATIONREFERENCE($,'Ac_05_10_17','Cost estimate submission',#858,$,$); +#861=IFCCLASSIFICATIONREFERENCE($,'Ac_05_10_29','Feasibility study preparation',#858,$,$); +#862=IFCCLASSIFICATIONREFERENCE($,'Ac_05_10_31','Feasibility study submission',#858,$,$); +#863=IFCCLASSIFICATIONREFERENCE($,'Ac_05_10_61','Preliminary design preparation',#858,$,$); +#864=IFCCLASSIFICATIONREFERENCE($,'Ac_05_10_63','Preliminary design submission',#858,$,$); +#865=IFCCLASSIFICATIONREFERENCE($,'Ac_05_10_65','Project brief and objectives preparation',#858,$,$); +#866=IFCCLASSIFICATIONREFERENCE($,'Ac_05_10_67','Project brief and objectives submission',#858,$,$); +#867=IFCCLASSIFICATIONREFERENCE($,'Ac_05_20','Concept stage activities',#853,$,$); +#868=IFCCLASSIFICATIONREFERENCE($,'Ac_05_20_15','Concept cost report preparation',#867,$,$); +#869=IFCCLASSIFICATIONREFERENCE($,'Ac_05_20_17','Concept cost report submission',#867,$,$); +#870=IFCCLASSIFICATIONREFERENCE($,'Ac_05_20_21','Concept design development',#867,$,$); +#871=IFCCLASSIFICATIONREFERENCE($,'Ac_05_20_23','Concept design report preparation',#867,$,$); +#872=IFCCLASSIFICATIONREFERENCE($,'Ac_05_20_25','Concept design report submission',#867,$,$); +#873=IFCCLASSIFICATIONREFERENCE($,'Ac_05_30','Definition stage activities',#853,$,$); +#874=IFCCLASSIFICATIONREFERENCE($,'Ac_05_30_03','Agreement negotiating',#873,$,$); +#875=IFCCLASSIFICATIONREFERENCE($,'Ac_05_30_10','Building regulation assessing',#873,$,$); +#876=IFCCLASSIFICATIONREFERENCE($,'Ac_05_30_21','Definition design cost report preparation',#873,$,$); +#877=IFCCLASSIFICATIONREFERENCE($,'Ac_05_30_23','Definition design cost report submission',#873,$,$); +#878=IFCCLASSIFICATIONREFERENCE($,'Ac_05_30_25','Definition design development',#873,$,$); +#879=IFCCLASSIFICATIONREFERENCE($,'Ac_05_30_27','Definition design report preparation',#873,$,$); +#880=IFCCLASSIFICATIONREFERENCE($,'Ac_05_30_28','Definition design submission',#873,$,$); +#881=IFCCLASSIFICATIONREFERENCE($,'Ac_05_30_29','Drainage adoption agreeing',#873,$,$); +#882=IFCCLASSIFICATIONREFERENCE($,'Ac_05_30_37','Highways adoption agreeing',#873,$,$); +#883=IFCCLASSIFICATIONREFERENCE($,'Ac_05_30_60','Party wall notices agreeing',#873,$,$); +#884=IFCCLASSIFICATIONREFERENCE($,'Ac_05_30_64','Planning preparation',#873,$,$); +#885=IFCCLASSIFICATIONREFERENCE($,'Ac_05_30_85','Sustainability assessing',#873,$,$); +#886=IFCCLASSIFICATIONREFERENCE($,'Ac_05_40','Design stage activities',#853,$,$); +#887=IFCCLASSIFICATIONREFERENCE($,'Ac_05_40_60','Prototype requesting',#886,$,$); +#888=IFCCLASSIFICATIONREFERENCE($,'Ac_05_40_70','Sample requesting',#886,$,$); +#889=IFCCLASSIFICATIONREFERENCE($,'Ac_05_40_85','Technical design cost report preparation',#886,$,$); +#890=IFCCLASSIFICATIONREFERENCE($,'Ac_05_40_87','Technical design development',#886,$,$); +#891=IFCCLASSIFICATIONREFERENCE($,'Ac_05_40_89','Technical design report preparation',#886,$,$); +#892=IFCCLASSIFICATIONREFERENCE($,'Ac_05_40_91','Technical design submission',#886,$,$); +#893=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50','Build and commission stage activities',#853,$,$); +#894=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_15','Contractor mobilizing',#893,$,$); +#895=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_41','Information submitting',#893,$,$); +#896=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_43','Inspecting',#893,$,$); +#897=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_51','Measuring',#893,$,$); +#898=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_54','Monitoring',#893,$,$); +#899=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_60','Prototype submission',#893,$,$); +#900=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_70','Sample submission',#893,$,$); +#901=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_72','Setting out',#893,$,$); +#902=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_75','Starting on site',#893,$,$); +#903=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_85','Tender analyzing',#893,$,$); +#904=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_87','Tender negotiating',#893,$,$); +#905=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_89','Tender recommendation reporting',#893,$,$); +#906=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_91','Timber sourcing',#893,$,$); +#907=IFCCLASSIFICATIONREFERENCE($,'Ac_05_50_97','Works commencing',#893,$,$); +#908=IFCCLASSIFICATIONREFERENCE($,'Ac_05_60','Handover and close-out stage activities',#853,$,$); +#909=IFCCLASSIFICATIONREFERENCE($,'Ac_05_60_10','Building contract administrating',#908,$,$); +#910=IFCCLASSIFICATIONREFERENCE($,'Ac_05_60_15','Completing',#908,$,$); +#911=IFCCLASSIFICATIONREFERENCE($,'Ac_05_60_30','Final clean',#908,$,$); +#912=IFCCLASSIFICATIONREFERENCE($,'Ac_05_60_35','Handing over',#908,$,$); +#913=IFCCLASSIFICATIONREFERENCE($,'Ac_05_60_60','Partial handing over',#908,$,$); +#914=IFCCLASSIFICATIONREFERENCE($,'Ac_05_60_70','Rectifying non-compliant items',#908,$,$); +#915=IFCCLASSIFICATIONREFERENCE($,'Ac_05_60_80','Sectional completing',#908,$,$); +#916=IFCCLASSIFICATIONREFERENCE($,'Ac_05_70','Operation and end of life stage activities',#853,$,$); +#917=IFCCLASSIFICATIONREFERENCE($,'Ac_05_70_10','Building user assisting',#916,$,$); +#918=IFCCLASSIFICATIONREFERENCE($,'Ac_05_70_48','Logistics',#916,$,$); +#919=IFCCLASSIFICATIONREFERENCE($,'Ac_10','Preparation, construction and repair',#852,$,$); +#920=IFCCLASSIFICATIONREFERENCE($,'Ac_10_10','Deconstruction and demolition',#919,$,$); +#921=IFCCLASSIFICATIONREFERENCE($,'Ac_10_10_20','Deconstruction',#920,$,$); +#922=IFCCLASSIFICATIONREFERENCE($,'Ac_10_10_25','Demolition',#920,$,$); +#923=IFCCLASSIFICATIONREFERENCE($,'Ac_10_20','Decontamination',#919,$,$); +#924=IFCCLASSIFICATIONREFERENCE($,'Ac_10_30','Site clearance',#919,$,$); +#925=IFCCLASSIFICATIONREFERENCE($,'Ac_10_30_10','Bush and scrub removal',#924,$,$); +#926=IFCCLASSIFICATIONREFERENCE($,'Ac_10_30_15','Constructed material clearance',#924,$,$); +#927=IFCCLASSIFICATIONREFERENCE($,'Ac_10_30_80','Soil removal',#924,$,$); +#928=IFCCLASSIFICATIONREFERENCE($,'Ac_10_30_90','Tree removal',#924,$,$); +#929=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40','Construction',#919,$,$); +#930=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40_08','Bricklaying',#929,$,$); +#931=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40_11','Carpentry and joinery',#929,$,$); +#932=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40_13','Carpet laying',#929,$,$); +#933=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40_22','Diamond drilling',#929,$,$); +#934=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40_25','Ductwork installing',#929,$,$); +#935=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40_27','Electrical system installing',#929,$,$); +#936=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40_30','Formwork installing',#929,$,$); +#937=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40_41','Internal fitting out',#929,$,$); +#938=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40_60','Painting and decorating',#929,$,$); +#939=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40_63','Pipe fitting',#929,$,$); +#940=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40_65','Plastering and rendering',#929,$,$); +#941=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40_67','Plumbing',#929,$,$); +#942=IFCCLASSIFICATIONREFERENCE($,'Ac_10_40_88','Tiling',#929,$,$); +#943=IFCCLASSIFICATIONREFERENCE($,'Ac_10_60','Protection activities',#919,$,$); +#944=IFCCLASSIFICATIONREFERENCE($,'Ac_10_60_90','Tree protecting',#943,$,$); +#945=IFCCLASSIFICATIONREFERENCE($,'Ac_10_70','Remediation, repair and renovation',#919,$,$); +#946=IFCCLASSIFICATIONREFERENCE($,'Ac_10_70_65','Remediation',#945,$,$); +#947=IFCCLASSIFICATIONREFERENCE($,'Ac_10_70_70','Renovation',#945,$,$); +#948=IFCCLASSIFICATIONREFERENCE($,'Ac_10_70_75','Repair',#945,$,$); +#949=IFCCLASSIFICATIONREFERENCE($,'Ac_10_80','Structure moving',#919,$,$); +#950=IFCCLASSIFICATIONREFERENCE($,'Ac_15','Survey activities',#852,$,$); +#951=IFCCLASSIFICATIONREFERENCE($,'Ac_15_05','Aquatic surveying',#950,$,$); +#952=IFCCLASSIFICATIONREFERENCE($,'Ac_15_05_11','Canals surveying',#951,$,$); +#953=IFCCLASSIFICATIONREFERENCE($,'Ac_15_05_15','Coastal surveying',#951,$,$); +#954=IFCCLASSIFICATIONREFERENCE($,'Ac_15_05_36','Hydrological surveying',#951,$,$); +#955=IFCCLASSIFICATIONREFERENCE($,'Ac_15_05_46','Lakes and ponds surveying',#951,$,$); +#956=IFCCLASSIFICATIONREFERENCE($,'Ac_15_05_70','Reservoirs surveying',#951,$,$); +#957=IFCCLASSIFICATIONREFERENCE($,'Ac_15_05_72','Rivers and streams surveying',#951,$,$); +#958=IFCCLASSIFICATIONREFERENCE($,'Ac_15_05_73','River estuary surveying',#951,$,$); +#959=IFCCLASSIFICATIONREFERENCE($,'Ac_15_10','Surveying methods',#950,$,$); +#960=IFCCLASSIFICATIONREFERENCE($,'Ac_15_10_01','Acoustic surveying',#959,$,$); +#961=IFCCLASSIFICATIONREFERENCE($,'Ac_15_10_03','Aerial surveying',#959,$,$); +#962=IFCCLASSIFICATIONREFERENCE($,'Ac_15_10_10','Borehole surveying',#959,$,$); +#963=IFCCLASSIFICATIONREFERENCE($,'Ac_15_10_14','Closed-circuit television surveying',#959,$,$); +#964=IFCCLASSIFICATIONREFERENCE($,'Ac_15_10_22','Desk top studying',#959,$,$); +#965=IFCCLASSIFICATIONREFERENCE($,'Ac_15_10_32','Geophysical surveying',#959,$,$); +#966=IFCCLASSIFICATIONREFERENCE($,'Ac_15_10_34','Ground penetrating radar surveying',#959,$,$); +#967=IFCCLASSIFICATIONREFERENCE($,'Ac_15_10_70','Radio frequency location surveying',#959,$,$); +#968=IFCCLASSIFICATIONREFERENCE($,'Ac_15_10_80','Satellite surveying',#959,$,$); +#969=IFCCLASSIFICATIONREFERENCE($,'Ac_15_10_90','Trial holes surveying',#959,$,$); +#970=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15','Building services condition surveying',#950,$,$); +#971=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15_06','Below ground services surveying',#970,$,$); +#972=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15_08','Boilers, heating and hot water systems surveying',#970,$,$); +#973=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15_11','Catering equipment surveying',#970,$,$); +#974=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15_15','Cold water and water treatment systems surveying',#970,$,$); +#975=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15_16','Control systems surveying',#970,$,$); +#976=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15_28','Escalator and moving pavement systems surveying',#970,$,$); +#977=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15_30','Fire alarm systems surveying',#970,$,$); +#978=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15_34','Generators system surveying',#970,$,$); +#979=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15_47','Lift installation surveying',#970,$,$); +#980=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15_48','Low voltage general power electrical installations surveying',#970,$,$); +#981=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15_71','Refrigeration systems surveying',#970,$,$); +#982=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15_82','Sprinkler systems surveying',#970,$,$); +#983=IFCCLASSIFICATIONREFERENCE($,'Ac_15_15_95','Ventilation and air conditioning systems surveying',#970,$,$); +#984=IFCCLASSIFICATIONREFERENCE($,'Ac_15_20','Ecological and environmental surveying',#950,$,$); +#985=IFCCLASSIFICATIONREFERENCE($,'Ac_15_20_03','Animal conservation assessment surveying',#984,$,$); +#986=IFCCLASSIFICATIONREFERENCE($,'Ac_15_20_05','Arboricultural surveying',#984,$,$); +#987=IFCCLASSIFICATIONREFERENCE($,'Ac_15_20_08','Bird and pest surveying',#984,$,$); +#988=IFCCLASSIFICATIONREFERENCE($,'Ac_15_20_25','Ecological building surveying',#984,$,$); +#989=IFCCLASSIFICATIONREFERENCE($,'Ac_15_20_27','Ecological site surveying',#984,$,$); +#990=IFCCLASSIFICATIONREFERENCE($,'Ac_15_20_28','Environmental impact assessment surveying',#984,$,$); +#991=IFCCLASSIFICATIONREFERENCE($,'Ac_15_20_40','Invasive species surveying',#984,$,$); +#992=IFCCLASSIFICATIONREFERENCE($,'Ac_15_20_46','Landscape character assessing',#984,$,$); +#993=IFCCLASSIFICATIONREFERENCE($,'Ac_15_20_48','Landscape visual assessing',#984,$,$); +#994=IFCCLASSIFICATIONREFERENCE($,'Ac_15_20_56','Nuisance animal species surveying',#984,$,$); +#995=IFCCLASSIFICATIONREFERENCE($,'Ac_15_20_58','Ornithological surveying',#984,$,$); +#996=IFCCLASSIFICATIONREFERENCE($,'Ac_15_20_85','Strategic environmental assessing',#984,$,$); +#997=IFCCLASSIFICATIONREFERENCE($,'Ac_15_30','Geometric surveying',#950,$,$); +#998=IFCCLASSIFICATIONREFERENCE($,'Ac_15_30_50','Measured and metric surveying',#997,$,$); +#999=IFCCLASSIFICATIONREFERENCE($,'Ac_15_30_90','Topographical surveying',#997,$,$); +#1000=IFCCLASSIFICATIONREFERENCE($,'Ac_15_40','Hazardous material surveying',#950,$,$); +#1001=IFCCLASSIFICATIONREFERENCE($,'Ac_15_40_05','Asbestos surveying',#1000,$,$); +#1002=IFCCLASSIFICATIONREFERENCE($,'Ac_15_40_45','Lead paint surveying',#1000,$,$); +#1003=IFCCLASSIFICATIONREFERENCE($,'Ac_15_40_70','Radon and hazardous ground gases surveying',#1000,$,$); +#1004=IFCCLASSIFICATIONREFERENCE($,'Ac_15_45','Historic building and site surveying',#950,$,$); +#1005=IFCCLASSIFICATIONREFERENCE($,'Ac_15_45_35','Historic building surveying',#1004,$,$); +#1006=IFCCLASSIFICATIONREFERENCE($,'Ac_15_45_37','Historic site surveying',#1004,$,$); +#1007=IFCCLASSIFICATIONREFERENCE($,'Ac_15_50','Building fabric surveying',#950,$,$); +#1008=IFCCLASSIFICATIONREFERENCE($,'Ac_15_50_10','Building surveying',#1007,$,$); +#1009=IFCCLASSIFICATIONREFERENCE($,'Ac_15_50_15','Concealed elements surveying',#1007,$,$); +#1010=IFCCLASSIFICATIONREFERENCE($,'Ac_15_50_17','Concrete cover surveying',#1007,$,$); +#1011=IFCCLASSIFICATIONREFERENCE($,'Ac_15_50_20','Damp ingress and excess moisture surveying',#1007,$,$); +#1012=IFCCLASSIFICATIONREFERENCE($,'Ac_15_50_22','Dilapidations surveying',#1007,$,$); +#1013=IFCCLASSIFICATIONREFERENCE($,'Ac_15_50_25','Doors, windows and glazing surveying',#1007,$,$); +#1014=IFCCLASSIFICATIONREFERENCE($,'Ac_15_50_50','Masonry surveying',#1007,$,$); +#1015=IFCCLASSIFICATIONREFERENCE($,'Ac_15_50_52','Metalwork surveying',#1007,$,$); +#1016=IFCCLASSIFICATIONREFERENCE($,'Ac_15_50_73','Roof surveying',#1007,$,$); +#1017=IFCCLASSIFICATIONREFERENCE($,'Ac_15_50_85','Structural surveying',#1007,$,$); +#1018=IFCCLASSIFICATIONREFERENCE($,'Ac_15_50_90','Timber surveying',#1007,$,$); +#1019=IFCCLASSIFICATIONREFERENCE($,'Ac_15_55','Performance surveying',#950,$,$); +#1020=IFCCLASSIFICATIONREFERENCE($,'Ac_15_55_02','Access auditing',#1019,$,$); +#1021=IFCCLASSIFICATIONREFERENCE($,'Ac_15_55_04','Acoustics and noise transfer surveying',#1019,$,$); +#1022=IFCCLASSIFICATIONREFERENCE($,'Ac_15_55_06','Airtightness surveying',#1019,$,$); +#1023=IFCCLASSIFICATIONREFERENCE($,'Ac_15_55_26','Energy assessment surveying',#1019,$,$); +#1024=IFCCLASSIFICATIONREFERENCE($,'Ac_15_55_30','Fire protection surveying',#1019,$,$); +#1025=IFCCLASSIFICATIONREFERENCE($,'Ac_15_55_75','Security auditing',#1019,$,$); +#1026=IFCCLASSIFICATIONREFERENCE($,'Ac_15_60','Rail track surveying',#950,$,$); +#1027=IFCCLASSIFICATIONREFERENCE($,'Ac_15_70','Road and bridge surveying',#950,$,$); +#1028=IFCCLASSIFICATIONREFERENCE($,'Ac_15_70_70','Road safety auditing',#1027,$,$); +#1029=IFCCLASSIFICATIONREFERENCE($,'Ac_15_70_90','Traffic surveying',#1027,$,$); +#1030=IFCCLASSIFICATIONREFERENCE($,'Ac_15_75','Ground investigating',#950,$,$); +#1031=IFCCLASSIFICATIONREFERENCE($,'Ac_15_75_20','Geochemical surveying',#1030,$,$); +#1032=IFCCLASSIFICATIONREFERENCE($,'Ac_15_75_25','Geoenvironmental exploratory investigating',#1030,$,$); +#1033=IFCCLASSIFICATIONREFERENCE($,'Ac_15_75_30','Geoenvironmental ground investigating',#1030,$,$); +#1034=IFCCLASSIFICATIONREFERENCE($,'Ac_15_75_35','Geological boundaries surveying',#1030,$,$); +#1035=IFCCLASSIFICATIONREFERENCE($,'Ac_15_75_40','Geological faults surveying',#1030,$,$); +#1036=IFCCLASSIFICATIONREFERENCE($,'Ac_15_75_45','Geological surveying',#1030,$,$); +#1037=IFCCLASSIFICATIONREFERENCE($,'Ac_15_75_50','Geotechnical ground investigating',#1030,$,$); +#1038=IFCCLASSIFICATIONREFERENCE($,'Ac_15_75_55','Geotechnical substructure investigating',#1030,$,$); +#1039=IFCCLASSIFICATIONREFERENCE($,'Ac_15_75_60','Ground levels surveying',#1030,$,$); +#1040=IFCCLASSIFICATIONREFERENCE($,'Ac_15_75_65','Ground water table surveying',#1030,$,$); +#1041=IFCCLASSIFICATIONREFERENCE($,'Ac_15_75_70','Preliminary site investigating',#1030,$,$); +#1042=IFCCLASSIFICATIONREFERENCE($,'Ac_15_75_80','Soil surveying',#1030,$,$); +#1043=IFCCLASSIFICATIONREFERENCE($,'Ac_15_80','Site surveying',#950,$,$); +#1044=IFCCLASSIFICATIONREFERENCE($,'Ac_15_80_65','Preliminary site surveying',#1043,$,$); +#1045=IFCCLASSIFICATIONREFERENCE($,'Ac_15_80_92','Utilities surveying',#1043,$,$); +#1046=IFCCLASSIFICATIONREFERENCE($,'Ac_15_90','Tunnel surveying',#950,$,$); +#1047=IFCCLASSIFICATIONREFERENCE($,'Ac_20','Administrative, commercial and protective services activities',#852,$,$); +#1048=IFCCLASSIFICATIONREFERENCE($,'Ac_20_10','Legislative activities',#1047,$,$); +#1049=IFCCLASSIFICATIONREFERENCE($,'Ac_20_10_47','Legislating activities',#1048,$,$); +#1050=IFCCLASSIFICATIONREFERENCE($,'Ac_20_10_66','Public viewing of legislating activities',#1048,$,$); +#1051=IFCCLASSIFICATIONREFERENCE($,'Ac_20_15','Administrative office activities',#1047,$,$); +#1052=IFCCLASSIFICATIONREFERENCE($,'Ac_20_15_15','Counter service',#1051,$,$); +#1053=IFCCLASSIFICATIONREFERENCE($,'Ac_20_15_22','Desk-based office tasks',#1051,$,$); +#1054=IFCCLASSIFICATIONREFERENCE($,'Ac_20_15_50','Meetings',#1051,$,$); +#1055=IFCCLASSIFICATIONREFERENCE($,'Ac_20_15_59','Office maintenance tasks',#1051,$,$); +#1056=IFCCLASSIFICATIONREFERENCE($,'Ac_20_15_71','Reception tasks',#1051,$,$); +#1057=IFCCLASSIFICATIONREFERENCE($,'Ac_20_45','Motor vehicle maintenance and fuelling activities',#1047,$,$); +#1058=IFCCLASSIFICATIONREFERENCE($,'Ac_20_45_30','Fuel station air and water dispensing',#1057,$,$); +#1059=IFCCLASSIFICATIONREFERENCE($,'Ac_20_45_31','Fuel station fuel storing',#1057,$,$); +#1060=IFCCLASSIFICATIONREFERENCE($,'Ac_20_45_51','Motor vehicle fuelling',#1057,$,$); +#1061=IFCCLASSIFICATIONREFERENCE($,'Ac_20_45_53','Motor vehicle maintaining',#1057,$,$); +#1062=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50','Commercial activities',#1047,$,$); +#1063=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_03','Ambient products wholesale selling',#1062,$,$); +#1064=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_05','Auctioning',#1062,$,$); +#1065=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_12','Checking out and paying',#1062,$,$); +#1066=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_22','Department store retail selling',#1062,$,$); +#1067=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_29','Financial and professional services activity',#1062,$,$); +#1068=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_32','Food and drink retail selling',#1062,$,$); +#1069=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_33','General retail selling',#1062,$,$); +#1070=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_36','Hair and beauty treatment activities',#1062,$,$); +#1071=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_45','Kiosk retail selling',#1062,$,$); +#1072=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_47','Livestock wholesale selling',#1062,$,$); +#1073=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_50','Mail order sorting and despatching',#1062,$,$); +#1074=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_51','Market retail selling',#1062,$,$); +#1075=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_55','Motor vehicle selling',#1062,$,$); +#1076=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_70','Refrigerated products wholesale selling',#1062,$,$); +#1077=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_85','Supermarket retail selling',#1062,$,$); +#1078=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_87','Tattooing and piercing',#1062,$,$); +#1079=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_90','Trying out goods',#1062,$,$); +#1080=IFCCLASSIFICATIONREFERENCE($,'Ac_20_50_96','Waste and scrap wholesale selling',#1062,$,$); +#1081=IFCCLASSIFICATIONREFERENCE($,'Ac_20_55','Postal communications activities',#1047,$,$); +#1082=IFCCLASSIFICATIONREFERENCE($,'Ac_20_55_45','Letter sorting',#1081,$,$); +#1083=IFCCLASSIFICATIONREFERENCE($,'Ac_20_55_60','Parcel sorting',#1081,$,$); +#1084=IFCCLASSIFICATIONREFERENCE($,'Ac_20_60','Military protective activities',#1047,$,$); +#1085=IFCCLASSIFICATIONREFERENCE($,'Ac_20_60_08','Bombardment sheltering',#1084,$,$); +#1086=IFCCLASSIFICATIONREFERENCE($,'Ac_20_60_70','Radioactive fallout sheltering',#1084,$,$); +#1087=IFCCLASSIFICATIONREFERENCE($,'Ac_20_62','Parade activities',#1047,$,$); +#1088=IFCCLASSIFICATIONREFERENCE($,'Ac_20_62_65','Parading',#1087,$,$); +#1089=IFCCLASSIFICATIONREFERENCE($,'Ac_20_65','Law enforcement activities',#1047,$,$); +#1090=IFCCLASSIFICATIONREFERENCE($,'Ac_20_65_08','Breathalyzing',#1089,$,$); +#1091=IFCCLASSIFICATIONREFERENCE($,'Ac_20_65_15','Counter terrorism activities',#1089,$,$); +#1092=IFCCLASSIFICATIONREFERENCE($,'Ac_20_65_19','Custody activities',#1089,$,$); +#1093=IFCCLASSIFICATIONREFERENCE($,'Ac_20_65_40','Identification parading',#1089,$,$); +#1094=IFCCLASSIFICATIONREFERENCE($,'Ac_20_65_59','Operational activities',#1089,$,$); +#1095=IFCCLASSIFICATIONREFERENCE($,'Ac_20_65_65','Police detaining',#1089,$,$); +#1096=IFCCLASSIFICATIONREFERENCE($,'Ac_20_65_87','Testing for illegal substances',#1089,$,$); +#1097=IFCCLASSIFICATIONREFERENCE($,'Ac_20_65_94','Victim examining',#1089,$,$); +#1098=IFCCLASSIFICATIONREFERENCE($,'Ac_20_70','Judicial activities',#1047,$,$); +#1099=IFCCLASSIFICATIONREFERENCE($,'Ac_20_70_15','Conducting trials and hearings',#1098,$,$); +#1100=IFCCLASSIFICATIONREFERENCE($,'Ac_20_70_23','Defendant seating',#1098,$,$); +#1101=IFCCLASSIFICATIONREFERENCE($,'Ac_20_70_27','Evidence drying',#1098,$,$); +#1102=IFCCLASSIFICATIONREFERENCE($,'Ac_20_70_41','Judicial seating',#1098,$,$); +#1103=IFCCLASSIFICATIONREFERENCE($,'Ac_20_70_44','Jury seating',#1098,$,$); +#1104=IFCCLASSIFICATIONREFERENCE($,'Ac_20_70_68','Public gallery viewing',#1098,$,$); +#1105=IFCCLASSIFICATIONREFERENCE($,'Ac_20_70_93','Victim supporting',#1098,$,$); +#1106=IFCCLASSIFICATIONREFERENCE($,'Ac_20_70_94','Vulnerable victim supporting',#1098,$,$); +#1107=IFCCLASSIFICATIONREFERENCE($,'Ac_20_70_95','Vulnerable witness supporting',#1098,$,$); +#1108=IFCCLASSIFICATIONREFERENCE($,'Ac_20_70_97','Witness standing',#1098,$,$); +#1109=IFCCLASSIFICATIONREFERENCE($,'Ac_20_70_98','Witness supporting',#1098,$,$); +#1110=IFCCLASSIFICATIONREFERENCE($,'Ac_20_75','Detention activities',#1047,$,$); +#1111=IFCCLASSIFICATIONREFERENCE($,'Ac_20_75_12','Close supervising',#1110,$,$); +#1112=IFCCLASSIFICATIONREFERENCE($,'Ac_20_75_15','Communal inmate day activities',#1110,$,$); +#1113=IFCCLASSIFICATIONREFERENCE($,'Ac_20_75_20','Detainee exercising',#1110,$,$); +#1114=IFCCLASSIFICATIONREFERENCE($,'Ac_20_75_22','Detainee processing',#1110,$,$); +#1115=IFCCLASSIFICATIONREFERENCE($,'Ac_20_75_35','Guarding detainees',#1110,$,$); +#1116=IFCCLASSIFICATIONREFERENCE($,'Ac_20_75_38','Holding of prisoners',#1110,$,$); +#1117=IFCCLASSIFICATIONREFERENCE($,'Ac_20_75_41','Inmate exercising',#1110,$,$); +#1118=IFCCLASSIFICATIONREFERENCE($,'Ac_20_75_44','Juvenile detaining',#1110,$,$); +#1119=IFCCLASSIFICATIONREFERENCE($,'Ac_20_75_67','Prison detaining',#1110,$,$); +#1120=IFCCLASSIFICATIONREFERENCE($,'Ac_20_75_75','Secure entering and exiting',#1110,$,$); +#1121=IFCCLASSIFICATIONREFERENCE($,'Ac_20_75_77','Secure visiting',#1110,$,$); +#1122=IFCCLASSIFICATIONREFERENCE($,'Ac_20_75_95','Vehicle impounding',#1110,$,$); +#1123=IFCCLASSIFICATIONREFERENCE($,'Ac_20_80','Weapons training activities',#1047,$,$); +#1124=IFCCLASSIFICATIONREFERENCE($,'Ac_20_80_29','Firearms training',#1123,$,$); +#1125=IFCCLASSIFICATIONREFERENCE($,'Ac_20_80_31','Firing of weapons',#1123,$,$); +#1126=IFCCLASSIFICATIONREFERENCE($,'Ac_20_85','Security activities',#1047,$,$); +#1127=IFCCLASSIFICATIONREFERENCE($,'Ac_20_85_08','Biometric identifying',#1126,$,$); +#1128=IFCCLASSIFICATIONREFERENCE($,'Ac_20_85_63','Pedestrian security checking',#1126,$,$); +#1129=IFCCLASSIFICATIONREFERENCE($,'Ac_20_85_77','Secure activities',#1126,$,$); +#1130=IFCCLASSIFICATIONREFERENCE($,'Ac_20_85_79','Sensitive activities',#1126,$,$); +#1131=IFCCLASSIFICATIONREFERENCE($,'Ac_20_85_95','Vehicular security checking',#1126,$,$); +#1132=IFCCLASSIFICATIONREFERENCE($,'Ac_20_90','Incident support activities',#1047,$,$); +#1133=IFCCLASSIFICATIONREFERENCE($,'Ac_20_90_31','Fire training',#1132,$,$); +#1134=IFCCLASSIFICATIONREFERENCE($,'Ac_20_90_41','Incident prevention',#1132,$,$); +#1135=IFCCLASSIFICATIONREFERENCE($,'Ac_20_90_42','Incident support',#1132,$,$); +#1136=IFCCLASSIFICATIONREFERENCE($,'Ac_20_90_78','Sheltering from fire',#1132,$,$); +#1137=IFCCLASSIFICATIONREFERENCE($,'Ac_25','Cultural, educational, scientific and information activities',#852,$,$); +#1138=IFCCLASSIFICATIONREFERENCE($,'Ac_25_05','Commemoration activities',#1137,$,$); +#1139=IFCCLASSIFICATIONREFERENCE($,'Ac_25_05_15','Commemoration events',#1138,$,$); +#1140=IFCCLASSIFICATIONREFERENCE($,'Ac_25_10','Educational activities',#1137,$,$); +#1141=IFCCLASSIFICATIONREFERENCE($,'Ac_25_10_05','Assembling',#1140,$,$); +#1142=IFCCLASSIFICATIONREFERENCE($,'Ac_25_10_15','Communal educational activities',#1140,$,$); +#1143=IFCCLASSIFICATIONREFERENCE($,'Ac_25_10_26','Driving tuition',#1140,$,$); +#1144=IFCCLASSIFICATIONREFERENCE($,'Ac_25_10_35','Group work',#1140,$,$); +#1145=IFCCLASSIFICATIONREFERENCE($,'Ac_25_10_47','Lecturing',#1140,$,$); +#1146=IFCCLASSIFICATIONREFERENCE($,'Ac_25_10_71','Researching',#1140,$,$); +#1147=IFCCLASSIFICATIONREFERENCE($,'Ac_25_10_78','Seminar activities',#1140,$,$); +#1148=IFCCLASSIFICATIONREFERENCE($,'Ac_25_10_84','Studying',#1140,$,$); +#1149=IFCCLASSIFICATIONREFERENCE($,'Ac_25_10_88','Teaching',#1140,$,$); +#1150=IFCCLASSIFICATIONREFERENCE($,'Ac_25_20','Design and craft activities',#1137,$,$); +#1151=IFCCLASSIFICATIONREFERENCE($,'Ac_25_20_13','Ceramics making',#1150,$,$); +#1152=IFCCLASSIFICATIONREFERENCE($,'Ac_25_20_15','Craft activities',#1150,$,$); +#1153=IFCCLASSIFICATIONREFERENCE($,'Ac_25_20_21','Designing',#1150,$,$); +#1154=IFCCLASSIFICATIONREFERENCE($,'Ac_25_20_24','Drawing',#1150,$,$); +#1155=IFCCLASSIFICATIONREFERENCE($,'Ac_25_20_60','Painting',#1150,$,$); +#1156=IFCCLASSIFICATIONREFERENCE($,'Ac_25_20_88','Technical drawing',#1150,$,$); +#1157=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30','Scientific and laboratory activities',#1137,$,$); +#1158=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_02','Anechoic chamber activities',#1157,$,$); +#1159=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_04','Astronomy activities',#1157,$,$); +#1160=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_07','Biology activities',#1157,$,$); +#1161=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_10','Bioscience activities',#1157,$,$); +#1162=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_13','Chemistry activities',#1157,$,$); +#1163=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_15','Clinical biochemistry activities',#1157,$,$); +#1164=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_16','Clinical microbiology activities',#1157,$,$); +#1165=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_17','Clinical pathology activities',#1157,$,$); +#1166=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_19','Containment activities',#1157,$,$); +#1167=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_21','Dark room activities',#1157,$,$); +#1168=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_22','Dental laboratory activities',#1157,$,$); +#1169=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_23','Dissection',#1157,$,$); +#1170=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_26','Earth sciences activities',#1157,$,$); +#1171=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_27','Engineering activities',#1157,$,$); +#1172=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_28','Experiment controlling',#1157,$,$); +#1173=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_29','Flow cytometry activities',#1157,$,$); +#1174=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_30','Food testing',#1157,$,$); +#1175=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_31','Forensic science activities',#1157,$,$); +#1176=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_33','Geology activities',#1157,$,$); +#1177=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_36','Hyperbaric chamber activities',#1157,$,$); +#1178=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_46','Laboratory cold activities',#1157,$,$); +#1179=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_47','Laboratory warm activities',#1157,$,$); +#1180=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_50','Material testing',#1157,$,$); +#1181=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_66','Physics activities',#1157,$,$); +#1182=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_68','Psychology activities',#1157,$,$); +#1183=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_70','Radiation shielded activities',#1157,$,$); +#1184=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_72','Results interpreting',#1157,$,$); +#1185=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_76','Scientific instrument activities',#1157,$,$); +#1186=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_78','Seismograph activities',#1157,$,$); +#1187=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_85','Sterilizing activities',#1157,$,$); +#1188=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_89','Tissue culturing',#1157,$,$); +#1189=IFCCLASSIFICATIONREFERENCE($,'Ac_25_30_90','Toxicology activities',#1157,$,$); +#1190=IFCCLASSIFICATIONREFERENCE($,'Ac_25_50','Exhibition activities',#1137,$,$); +#1191=IFCCLASSIFICATIONREFERENCE($,'Ac_25_50_04','Art exhibiting',#1190,$,$); +#1192=IFCCLASSIFICATIONREFERENCE($,'Ac_25_50_15','Collection exhibiting',#1190,$,$); +#1193=IFCCLASSIFICATIONREFERENCE($,'Ac_25_50_16','Conservation of art and artefacts',#1190,$,$); +#1194=IFCCLASSIFICATIONREFERENCE($,'Ac_25_50_21','Diorama exhibiting',#1190,$,$); +#1195=IFCCLASSIFICATIONREFERENCE($,'Ac_25_50_29','Fauna exhibiting',#1190,$,$); +#1196=IFCCLASSIFICATIONREFERENCE($,'Ac_25_50_31','Flora exhibiting',#1190,$,$); +#1197=IFCCLASSIFICATIONREFERENCE($,'Ac_25_50_65','Projecting representations of the night sky',#1190,$,$); +#1198=IFCCLASSIFICATIONREFERENCE($,'Ac_25_50_73','Sculpture exhibiting',#1190,$,$); +#1199=IFCCLASSIFICATIONREFERENCE($,'Ac_25_50_94','Viewing activities',#1190,$,$); +#1200=IFCCLASSIFICATIONREFERENCE($,'Ac_25_70','Information activities',#1137,$,$); +#1201=IFCCLASSIFICATIONREFERENCE($,'Ac_25_70_04','Archiving',#1200,$,$); +#1202=IFCCLASSIFICATIONREFERENCE($,'Ac_25_70_05','Audio-visual studying',#1200,$,$); +#1203=IFCCLASSIFICATIONREFERENCE($,'Ac_25_70_11','Cataloguing',#1200,$,$); +#1204=IFCCLASSIFICATIONREFERENCE($,'Ac_25_70_23','Domestic book storing and reading',#1200,$,$); +#1205=IFCCLASSIFICATIONREFERENCE($,'Ac_25_70_30','Film storing',#1200,$,$); +#1206=IFCCLASSIFICATIONREFERENCE($,'Ac_25_70_47','Library storing',#1200,$,$); +#1207=IFCCLASSIFICATIONREFERENCE($,'Ac_25_70_71','Reading',#1200,$,$); +#1208=IFCCLASSIFICATIONREFERENCE($,'Ac_25_70_72','Records storing',#1200,$,$); +#1209=IFCCLASSIFICATIONREFERENCE($,'Ac_25_70_76','Scanning',#1200,$,$); +#1210=IFCCLASSIFICATIONREFERENCE($,'Ac_25_90','Worship activities',#1137,$,$); +#1211=IFCCLASSIFICATIONREFERENCE($,'Ac_25_90_12','Ceremonial worship activities',#1210,$,$); +#1212=IFCCLASSIFICATIONREFERENCE($,'Ac_25_90_15','Conducting acts of worship',#1210,$,$); +#1213=IFCCLASSIFICATIONREFERENCE($,'Ac_25_90_60','Pastoral care',#1210,$,$); +#1214=IFCCLASSIFICATIONREFERENCE($,'Ac_25_90_67','Preparing for acts of worship',#1210,$,$); +#1215=IFCCLASSIFICATIONREFERENCE($,'Ac_30','Industrial activities',#852,$,$); +#1216=IFCCLASSIFICATIONREFERENCE($,'Ac_30_10','Mineral extraction activities',#1215,$,$); +#1217=IFCCLASSIFICATIONREFERENCE($,'Ac_30_10_57','Offshore oil and gas drilling',#1216,$,$); +#1218=IFCCLASSIFICATIONREFERENCE($,'Ac_30_10_59','Onshore oil and gas drilling',#1216,$,$); +#1219=IFCCLASSIFICATIONREFERENCE($,'Ac_30_10_60','Opencast mining',#1216,$,$); +#1220=IFCCLASSIFICATIONREFERENCE($,'Ac_30_10_69','Quarrying',#1216,$,$); +#1221=IFCCLASSIFICATIONREFERENCE($,'Ac_30_10_91','Underground mining',#1216,$,$); +#1222=IFCCLASSIFICATIONREFERENCE($,'Ac_30_10_93','Underground mine accessing',#1216,$,$); +#1223=IFCCLASSIFICATIONREFERENCE($,'Ac_30_10_94','Underground mine tunnelling',#1216,$,$); +#1224=IFCCLASSIFICATIONREFERENCE($,'Ac_30_20','Nuclear and chemical management activities',#1215,$,$); +#1225=IFCCLASSIFICATIONREFERENCE($,'Ac_30_20_30','High heat highly enriched uranium radioactive waste managing',#1224,$,$); +#1226=IFCCLASSIFICATIONREFERENCE($,'Ac_30_20_35','High heat mixed oxide fuel radioactive waste managing',#1224,$,$); +#1227=IFCCLASSIFICATIONREFERENCE($,'Ac_30_20_40','High heat plutonium radioactive waste managing',#1224,$,$); +#1228=IFCCLASSIFICATIONREFERENCE($,'Ac_30_20_45','High heat radioactive waste managing',#1224,$,$); +#1229=IFCCLASSIFICATIONREFERENCE($,'Ac_30_20_50','High heat spent fuel radioactive waste managing',#1224,$,$); +#1230=IFCCLASSIFICATIONREFERENCE($,'Ac_30_20_60','Low heat depleted natural low enrichment uranium managing',#1224,$,$); +#1231=IFCCLASSIFICATIONREFERENCE($,'Ac_30_20_65','Low heat robust shielded radioactive waste managing',#1224,$,$); +#1232=IFCCLASSIFICATIONREFERENCE($,'Ac_30_20_70','Low heat shielded radioactive waste managing',#1224,$,$); +#1233=IFCCLASSIFICATIONREFERENCE($,'Ac_30_20_75','Low heat unshielded radioactive waste managing',#1224,$,$); +#1234=IFCCLASSIFICATIONREFERENCE($,'Ac_30_30','Mineral processing activities',#1215,$,$); +#1235=IFCCLASSIFICATIONREFERENCE($,'Ac_30_30_33','Gas processing',#1234,$,$); +#1236=IFCCLASSIFICATIONREFERENCE($,'Ac_30_30_58','Oil processing',#1234,$,$); +#1237=IFCCLASSIFICATIONREFERENCE($,'Ac_30_30_59','Ore processing',#1234,$,$); +#1238=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40','Animal and plant products processing activities',#1215,$,$); +#1239=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_06','Baking',#1238,$,$); +#1240=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_07','Bottling',#1238,$,$); +#1241=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_09','Brewing',#1238,$,$); +#1242=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_10','Butter-making',#1238,$,$); +#1243=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_11','Canning',#1238,$,$); +#1244=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_18','Cheese making',#1238,$,$); +#1245=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_22','Distilling',#1238,$,$); +#1246=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_30','Fish processing',#1238,$,$); +#1247=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_32','Fresh fruit and vegetable packing',#1238,$,$); +#1248=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_44','Juicing',#1238,$,$); +#1249=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_52','Meat processing',#1238,$,$); +#1250=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_54','Milk processing',#1238,$,$); +#1251=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_55','Milling',#1238,$,$); +#1252=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_63','Plant fibre sorting',#1238,$,$); +#1253=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_65','Poultry processing',#1238,$,$); +#1254=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_80','Slaughtering',#1238,$,$); +#1255=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_87','Tanning',#1238,$,$); +#1256=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_88','Threshing',#1238,$,$); +#1257=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_89','Timber sawing',#1238,$,$); +#1258=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_90','Tobacco drying',#1238,$,$); +#1259=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_96','Wine making',#1238,$,$); +#1260=IFCCLASSIFICATIONREFERENCE($,'Ac_30_40_98','Wool sorting',#1238,$,$); +#1261=IFCCLASSIFICATIONREFERENCE($,'Ac_30_50','Manufacturing activities',#1215,$,$); +#1262=IFCCLASSIFICATIONREFERENCE($,'Ac_30_50_27','Electronics clean activities',#1261,$,$); +#1263=IFCCLASSIFICATIONREFERENCE($,'Ac_30_50_30','Heavy industrial activities',#1261,$,$); +#1264=IFCCLASSIFICATIONREFERENCE($,'Ac_30_50_53','Light industrial activities',#1261,$,$); +#1265=IFCCLASSIFICATIONREFERENCE($,'Ac_30_50_60','Packaging',#1261,$,$); +#1266=IFCCLASSIFICATIONREFERENCE($,'Ac_30_50_61','Paint spraying',#1261,$,$); +#1267=IFCCLASSIFICATIONREFERENCE($,'Ac_30_50_64','Printing',#1261,$,$); +#1268=IFCCLASSIFICATIONREFERENCE($,'Ac_30_60','Cleaning and maintenance activities',#1215,$,$); +#1269=IFCCLASSIFICATIONREFERENCE($,'Ac_30_60_12','Cleaning',#1268,$,$); +#1270=IFCCLASSIFICATIONREFERENCE($,'Ac_30_60_13','Clothes drying and airing',#1268,$,$); +#1271=IFCCLASSIFICATIONREFERENCE($,'Ac_30_60_15','Commercial laundering',#1268,$,$); +#1272=IFCCLASSIFICATIONREFERENCE($,'Ac_30_60_22','Decontaminating',#1268,$,$); +#1273=IFCCLASSIFICATIONREFERENCE($,'Ac_30_60_23','Domestic laundering',#1268,$,$); +#1274=IFCCLASSIFICATIONREFERENCE($,'Ac_30_60_24','Dry cleaning',#1268,$,$); +#1275=IFCCLASSIFICATIONREFERENCE($,'Ac_30_60_42','Ironing',#1268,$,$); +#1276=IFCCLASSIFICATIONREFERENCE($,'Ac_30_60_47','Laundering',#1268,$,$); +#1277=IFCCLASSIFICATIONREFERENCE($,'Ac_30_60_75','Service laundering',#1268,$,$); +#1278=IFCCLASSIFICATIONREFERENCE($,'Ac_30_60_94','Vehicle washing',#1268,$,$); +#1279=IFCCLASSIFICATIONREFERENCE($,'Ac_30_60_96','Washing up',#1268,$,$); +#1280=IFCCLASSIFICATIONREFERENCE($,'Ac_30_80','Kinetic power generation',#1215,$,$); +#1281=IFCCLASSIFICATIONREFERENCE($,'Ac_30_85','Marine and water storage and maintenance activities',#1215,$,$); +#1282=IFCCLASSIFICATIONREFERENCE($,'Ac_30_85_08','Boat repairing',#1281,$,$); +#1283=IFCCLASSIFICATIONREFERENCE($,'Ac_30_85_24','Dry dock ship repairing',#1281,$,$); +#1284=IFCCLASSIFICATIONREFERENCE($,'Ac_30_85_30','Floating dock ship repairing',#1281,$,$); +#1285=IFCCLASSIFICATIONREFERENCE($,'Ac_30_85_97','Wet dock ship repairing',#1281,$,$); +#1286=IFCCLASSIFICATIONREFERENCE($,'Ac_30_90','Warehousing and distribution activities',#1215,$,$); +#1287=IFCCLASSIFICATIONREFERENCE($,'Ac_30_90_33','Goods delivery',#1286,$,$); +#1288=IFCCLASSIFICATIONREFERENCE($,'Ac_30_90_48','Loading and unloading',#1286,$,$); +#1289=IFCCLASSIFICATIONREFERENCE($,'Ac_30_90_80','Sorting and distributing',#1286,$,$); +#1290=IFCCLASSIFICATIONREFERENCE($,'Ac_30_90_96','Warehousing',#1286,$,$); +#1291=IFCCLASSIFICATIONREFERENCE($,'Ac_32','Water and land management activities',#852,$,$); +#1292=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10','Agricultural and horticultural activities',#1291,$,$); +#1293=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_02','Agricultural maintenance',#1292,$,$); +#1294=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_26','Farm yard activities',#1292,$,$); +#1295=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_27','Fertilizing',#1292,$,$); +#1296=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_29','Fish cultivating',#1292,$,$); +#1297=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_34','Glasshouse growing',#1292,$,$); +#1298=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_35','Harvesting',#1292,$,$); +#1299=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_36','Hedge laying',#1292,$,$); +#1300=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_38','Horticultural activities',#1292,$,$); +#1301=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_42','Irrigating',#1292,$,$); +#1302=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_47','Livestock activities',#1292,$,$); +#1303=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_52','Milking',#1292,$,$); +#1304=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_55','Mushroom cultivating',#1292,$,$); +#1305=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_61','Pest management',#1292,$,$); +#1306=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_64','Ploughing',#1292,$,$); +#1307=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_66','Poultry rearing',#1292,$,$); +#1308=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_68','Propagating',#1292,$,$); +#1309=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_70','Pruning',#1292,$,$); +#1310=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_77','Sheep shearing',#1292,$,$); +#1311=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_78','Sheep dipping',#1292,$,$); +#1312=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_79','Silviculture',#1292,$,$); +#1313=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_80','Sowing',#1292,$,$); +#1314=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_94','Viticulture',#1292,$,$); +#1315=IFCCLASSIFICATIONREFERENCE($,'Ac_32_10_96','Weed management',#1292,$,$); +#1316=IFCCLASSIFICATIONREFERENCE($,'Ac_32_50','Marine and water activities',#1291,$,$); +#1317=IFCCLASSIFICATIONREFERENCE($,'Ac_32_50_30','Flood defending',#1316,$,$); +#1318=IFCCLASSIFICATIONREFERENCE($,'Ac_32_50_38','Harbour protecting',#1316,$,$); +#1319=IFCCLASSIFICATIONREFERENCE($,'Ac_32_50_94','Vessel berthing',#1316,$,$); +#1320=IFCCLASSIFICATIONREFERENCE($,'Ac_32_50_95','Vessel launching',#1316,$,$); +#1321=IFCCLASSIFICATIONREFERENCE($,'Ac_32_60','Natural spaces activities',#1291,$,$); +#1322=IFCCLASSIFICATIONREFERENCE($,'Ac_32_60_27','Erosion',#1321,$,$); +#1323=IFCCLASSIFICATIONREFERENCE($,'Ac_32_60_30','Flooding',#1321,$,$); +#1324=IFCCLASSIFICATIONREFERENCE($,'Ac_35','Medical, health, welfare and sanitary activities',#852,$,$); +#1325=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10','Medical activities',#1324,$,$); +#1326=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_08','Birthing',#1325,$,$); +#1327=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_10','Burns treating',#1325,$,$); +#1328=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_15','Consulting',#1325,$,$); +#1329=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_31','First aiding',#1325,$,$); +#1330=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_36','Hearing testing',#1325,$,$); +#1331=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_39','Hydrotherapy',#1325,$,$); +#1332=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_42','Intensive caring',#1325,$,$); +#1333=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_43','Isolation caring',#1325,$,$); +#1334=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_51','Medical scanning',#1325,$,$); +#1335=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_53','Midwifery',#1325,$,$); +#1336=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_57','Nursing',#1325,$,$); +#1337=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_58','Occupational therapy',#1325,$,$); +#1338=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_61','Patient examining',#1325,$,$); +#1339=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_62','Patient screening',#1325,$,$); +#1340=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_64','Pharmaceutical dispensing',#1325,$,$); +#1341=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_65','Phototherapy',#1325,$,$); +#1342=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_66','Physiotherapy',#1325,$,$); +#1343=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_70','Radiography',#1325,$,$); +#1344=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_71','Radiotherapy',#1325,$,$); +#1345=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_74','Rehabilitating',#1325,$,$); +#1346=IFCCLASSIFICATIONREFERENCE($,'Ac_35_10_85','Surgical operating',#1325,$,$); +#1347=IFCCLASSIFICATIONREFERENCE($,'Ac_35_50','Welfare activities',#1324,$,$); +#1348=IFCCLASSIFICATIONREFERENCE($,'Ac_35_50_21','Day care',#1347,$,$); +#1349=IFCCLASSIFICATIONREFERENCE($,'Ac_35_50_42','Infant caring',#1347,$,$); +#1350=IFCCLASSIFICATIONREFERENCE($,'Ac_35_60','Food management activities',#1324,$,$); +#1351=IFCCLASSIFICATIONREFERENCE($,'Ac_35_60_16','Cooking',#1350,$,$); +#1352=IFCCLASSIFICATIONREFERENCE($,'Ac_35_60_30','Food preparation',#1350,$,$); +#1353=IFCCLASSIFICATIONREFERENCE($,'Ac_35_60_31','Food serving',#1350,$,$); +#1354=IFCCLASSIFICATIONREFERENCE($,'Ac_35_70','Funerary activities',#1324,$,$); +#1355=IFCCLASSIFICATIONREFERENCE($,'Ac_35_70_04','Ash urn storing',#1354,$,$); +#1356=IFCCLASSIFICATIONREFERENCE($,'Ac_35_70_10','Burial',#1354,$,$); +#1357=IFCCLASSIFICATIONREFERENCE($,'Ac_35_70_18','Cremating',#1354,$,$); +#1358=IFCCLASSIFICATIONREFERENCE($,'Ac_35_70_42','Interment in a vault or tomb',#1354,$,$); +#1359=IFCCLASSIFICATIONREFERENCE($,'Ac_35_80','Sanitary activities',#1324,$,$); +#1360=IFCCLASSIFICATIONREFERENCE($,'Ac_35_80_06','Baby changing',#1359,$,$); +#1361=IFCCLASSIFICATIONREFERENCE($,'Ac_35_80_07','Bathing',#1359,$,$); +#1362=IFCCLASSIFICATIONREFERENCE($,'Ac_35_80_80','Showering',#1359,$,$); +#1363=IFCCLASSIFICATIONREFERENCE($,'Ac_35_85','Animal activities',#1324,$,$); +#1364=IFCCLASSIFICATIONREFERENCE($,'Ac_35_85_02','Animal care',#1363,$,$); +#1365=IFCCLASSIFICATIONREFERENCE($,'Ac_35_85_04','Animal exercising',#1363,$,$); +#1366=IFCCLASSIFICATIONREFERENCE($,'Ac_35_85_88','Tack maintaining',#1363,$,$); +#1367=IFCCLASSIFICATIONREFERENCE($,'Ac_35_90','Animal medical, health, welfare, funerary and sanitary activities',#1324,$,$); +#1368=IFCCLASSIFICATIONREFERENCE($,'Ac_35_90_25','Animal drug dispensing',#1367,$,$); +#1369=IFCCLASSIFICATIONREFERENCE($,'Ac_35_90_32','Animal funerary activities',#1367,$,$); +#1370=IFCCLASSIFICATIONREFERENCE($,'Ac_35_90_34','Animal grooming',#1367,$,$); +#1371=IFCCLASSIFICATIONREFERENCE($,'Ac_35_90_39','Animal hydrotherapy',#1367,$,$); +#1372=IFCCLASSIFICATIONREFERENCE($,'Ac_35_90_59','Veterinary caring',#1367,$,$); +#1373=IFCCLASSIFICATIONREFERENCE($,'Ac_40','Recreational activities',#852,$,$); +#1374=IFCCLASSIFICATIONREFERENCE($,'Ac_40_05','Amusement activities',#1373,$,$); +#1375=IFCCLASSIFICATIONREFERENCE($,'Ac_40_05_03','Amusement arcade activities',#1374,$,$); +#1376=IFCCLASSIFICATIONREFERENCE($,'Ac_40_05_33','Gambling',#1374,$,$); +#1377=IFCCLASSIFICATIONREFERENCE($,'Ac_40_05_42','Indoor fairground riding',#1374,$,$); +#1378=IFCCLASSIFICATIONREFERENCE($,'Ac_40_05_58','Observing',#1374,$,$); +#1379=IFCCLASSIFICATIONREFERENCE($,'Ac_40_05_59','Outdoor activities',#1374,$,$); +#1380=IFCCLASSIFICATIONREFERENCE($,'Ac_40_05_60','Outdoor fairground riding',#1374,$,$); +#1381=IFCCLASSIFICATIONREFERENCE($,'Ac_40_05_63','Playing',#1374,$,$); +#1382=IFCCLASSIFICATIONREFERENCE($,'Ac_40_05_89','Theme park activities',#1374,$,$); +#1383=IFCCLASSIFICATIONREFERENCE($,'Ac_40_20','Dining activities',#1373,$,$); +#1384=IFCCLASSIFICATIONREFERENCE($,'Ac_40_20_09','Beverage dispensing',#1383,$,$); +#1385=IFCCLASSIFICATIONREFERENCE($,'Ac_40_20_27','Enclosed dining',#1383,$,$); +#1386=IFCCLASSIFICATIONREFERENCE($,'Ac_40_20_28','Food dispensing',#1383,$,$); +#1387=IFCCLASSIFICATIONREFERENCE($,'Ac_40_20_59','Outdoor dining',#1383,$,$); +#1388=IFCCLASSIFICATIONREFERENCE($,'Ac_40_35','Historic recreational activities',#1373,$,$); +#1389=IFCCLASSIFICATIONREFERENCE($,'Ac_40_35_37','Historic earthworks exploring',#1388,$,$); +#1390=IFCCLASSIFICATIONREFERENCE($,'Ac_40_35_38','Historic ruins exploring',#1388,$,$); +#1391=IFCCLASSIFICATIONREFERENCE($,'Ac_40_35_39','Historic sites exploring',#1388,$,$); +#1392=IFCCLASSIFICATIONREFERENCE($,'Ac_40_60','Performing arts performance activities',#1373,$,$); +#1393=IFCCLASSIFICATIONREFERENCE($,'Ac_40_60_13','Circus performing',#1392,$,$); +#1394=IFCCLASSIFICATIONREFERENCE($,'Ac_40_60_21','Dancing',#1392,$,$); +#1395=IFCCLASSIFICATIONREFERENCE($,'Ac_40_60_29','Fashion showing',#1392,$,$); +#1396=IFCCLASSIFICATIONREFERENCE($,'Ac_40_60_30','Filming',#1392,$,$); +#1397=IFCCLASSIFICATIONREFERENCE($,'Ac_40_60_31','Film screening',#1392,$,$); +#1398=IFCCLASSIFICATIONREFERENCE($,'Ac_40_60_38','Indoor music performing',#1392,$,$); +#1399=IFCCLASSIFICATIONREFERENCE($,'Ac_40_60_40','Indoor theatre activities',#1392,$,$); +#1400=IFCCLASSIFICATIONREFERENCE($,'Ac_40_60_55','Music recording',#1392,$,$); +#1401=IFCCLASSIFICATIONREFERENCE($,'Ac_40_60_58','Outdoor music performing',#1392,$,$); +#1402=IFCCLASSIFICATIONREFERENCE($,'Ac_40_60_59','Outdoor theatre activities',#1392,$,$); +#1403=IFCCLASSIFICATIONREFERENCE($,'Ac_40_65','Performing arts ancillary activities',#1373,$,$); +#1404=IFCCLASSIFICATIONREFERENCE($,'Ac_40_65_02','Amphitheatre seating',#1403,$,$); +#1405=IFCCLASSIFICATIONREFERENCE($,'Ac_40_65_03','Artiste changing and make-up activities',#1403,$,$); +#1406=IFCCLASSIFICATIONREFERENCE($,'Ac_40_65_04','Audience breaking out',#1403,$,$); +#1407=IFCCLASSIFICATIONREFERENCE($,'Ac_40_65_05','Audience seating',#1403,$,$); +#1408=IFCCLASSIFICATIONREFERENCE($,'Ac_40_65_06','Backstage activities',#1403,$,$); +#1409=IFCCLASSIFICATIONREFERENCE($,'Ac_40_65_55','Music recording controlling',#1403,$,$); +#1410=IFCCLASSIFICATIONREFERENCE($,'Ac_40_65_59','Overhead scenery storing',#1403,$,$); +#1411=IFCCLASSIFICATIONREFERENCE($,'Ac_40_65_76','Scenery controlling',#1403,$,$); +#1412=IFCCLASSIFICATIONREFERENCE($,'Ac_40_65_79','Sound controlling',#1403,$,$); +#1413=IFCCLASSIFICATIONREFERENCE($,'Ac_40_65_80','Sound excluding',#1403,$,$); +#1414=IFCCLASSIFICATIONREFERENCE($,'Ac_40_65_88','Theatrical lighting controlling',#1403,$,$); +#1415=IFCCLASSIFICATIONREFERENCE($,'Ac_40_65_89','Theatrical rehearsing',#1403,$,$); +#1416=IFCCLASSIFICATIONREFERENCE($,'Ac_42','Sports activities',#852,$,$); +#1417=IFCCLASSIFICATIONREFERENCE($,'Ac_42_15','Court, pitch and field sport activities',#1416,$,$); +#1418=IFCCLASSIFICATIONREFERENCE($,'Ac_42_15_30','Field athletics',#1417,$,$); +#1419=IFCCLASSIFICATIONREFERENCE($,'Ac_42_15_42','Indoor court sports',#1417,$,$); +#1420=IFCCLASSIFICATIONREFERENCE($,'Ac_42_15_58','Outdoor court sports',#1417,$,$); +#1421=IFCCLASSIFICATIONREFERENCE($,'Ac_42_15_59','Outdoor field sports',#1417,$,$); +#1422=IFCCLASSIFICATIONREFERENCE($,'Ac_42_15_90','Track athletics',#1417,$,$); +#1423=IFCCLASSIFICATIONREFERENCE($,'Ac_42_40','Indoor sports activities',#1416,$,$); +#1424=IFCCLASSIFICATIONREFERENCE($,'Ac_42_40_09','Bouldering',#1423,$,$); +#1425=IFCCLASSIFICATIONREFERENCE($,'Ac_42_40_14','Climbing wall activities',#1423,$,$); +#1426=IFCCLASSIFICATIONREFERENCE($,'Ac_42_40_28','Exercising',#1423,$,$); +#1427=IFCCLASSIFICATIONREFERENCE($,'Ac_42_40_37','Gymnastics',#1423,$,$); +#1428=IFCCLASSIFICATIONREFERENCE($,'Ac_42_40_79','Snooker, billiards and pool',#1423,$,$); +#1429=IFCCLASSIFICATIONREFERENCE($,'Ac_42_40_90','Ten pin bowling',#1423,$,$); +#1430=IFCCLASSIFICATIONREFERENCE($,'Ac_42_40_92','Track cycling',#1423,$,$); +#1431=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55','Outdoor sports activities',#1416,$,$); +#1432=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_01','Archery',#1431,$,$); +#1433=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_07','BMX cycling',#1431,$,$); +#1434=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_08','Bowling',#1431,$,$); +#1435=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_18','Cross-country cycling',#1431,$,$); +#1436=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_19','Cross-country rallying',#1431,$,$); +#1437=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_20','Cross-country running',#1431,$,$); +#1438=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_23','Dog racing',#1431,$,$); +#1439=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_26','Equestrian dressage',#1431,$,$); +#1440=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_27','Equestrian cross country eventing',#1431,$,$); +#1441=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_28','Equestrian show jumping',#1431,$,$); +#1442=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_30','Fishing',#1431,$,$); +#1443=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_34','Golfing',#1431,$,$); +#1444=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_39','Horse racing',#1431,$,$); +#1445=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_40','Hunting',#1431,$,$); +#1446=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_53','Motor racing',#1431,$,$); +#1447=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_58','Orienteering',#1431,$,$); +#1448=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_60','Parkour',#1431,$,$); +#1449=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_70','Recreational cycling',#1431,$,$); +#1450=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_71','Recreational walking',#1431,$,$); +#1451=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_72','Riding',#1431,$,$); +#1452=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_74','Running',#1431,$,$); +#1453=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_76','Skateboarding',#1431,$,$); +#1454=IFCCLASSIFICATIONREFERENCE($,'Ac_42_55_82','Speedway racing',#1431,$,$); +#1455=IFCCLASSIFICATIONREFERENCE($,'Ac_42_80','Sports ancillary activities',#1416,$,$); +#1456=IFCCLASSIFICATIONREFERENCE($,'Ac_42_80_15','Corporate and VIP spectating',#1455,$,$); +#1457=IFCCLASSIFICATIONREFERENCE($,'Ac_42_80_50','Manager and coach seating',#1455,$,$); +#1458=IFCCLASSIFICATIONREFERENCE($,'Ac_42_80_65','Press spectating',#1455,$,$); +#1459=IFCCLASSIFICATIONREFERENCE($,'Ac_42_80_72','Reserves seating',#1455,$,$); +#1460=IFCCLASSIFICATIONREFERENCE($,'Ac_42_85','Swimming activities',#1416,$,$); +#1461=IFCCLASSIFICATIONREFERENCE($,'Ac_42_85_15','Competition swimming',#1460,$,$); +#1462=IFCCLASSIFICATIONREFERENCE($,'Ac_42_85_22','Diving',#1460,$,$); +#1463=IFCCLASSIFICATIONREFERENCE($,'Ac_42_85_71','Recreational swimming',#1460,$,$); +#1464=IFCCLASSIFICATIONREFERENCE($,'Ac_42_85_80','Spa activities',#1460,$,$); +#1465=IFCCLASSIFICATIONREFERENCE($,'Ac_42_85_92','Underwater observation',#1460,$,$); +#1466=IFCCLASSIFICATIONREFERENCE($,'Ac_42_85_94','Water flume, slide and tube riding',#1460,$,$); +#1467=IFCCLASSIFICATIONREFERENCE($,'Ac_42_85_95','Water polo',#1460,$,$); +#1468=IFCCLASSIFICATIONREFERENCE($,'Ac_42_85_97','Wave riding',#1460,$,$); +#1469=IFCCLASSIFICATIONREFERENCE($,'Ac_42_85_98','Whirlpool bath activities',#1460,$,$); +#1470=IFCCLASSIFICATIONREFERENCE($,'Ac_42_90','Water activities',#1416,$,$); +#1471=IFCCLASSIFICATIONREFERENCE($,'Ac_42_90_11','Canoe slalom',#1470,$,$); +#1472=IFCCLASSIFICATIONREFERENCE($,'Ac_42_90_12','Canoe sprint',#1470,$,$); +#1473=IFCCLASSIFICATIONREFERENCE($,'Ac_42_90_50','Motor boating',#1470,$,$); +#1474=IFCCLASSIFICATIONREFERENCE($,'Ac_42_90_73','Rowing',#1470,$,$); +#1475=IFCCLASSIFICATIONREFERENCE($,'Ac_42_90_75','Sailing',#1470,$,$); +#1476=IFCCLASSIFICATIONREFERENCE($,'Ac_42_90_97','Water skiing',#1470,$,$); +#1477=IFCCLASSIFICATIONREFERENCE($,'Ac_42_90_98','White water canoeing',#1470,$,$); +#1478=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95','Winter sports activities',#1416,$,$); +#1479=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_02','Alpine skiing',#1478,$,$); +#1480=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_08','Bobsleighing',#1478,$,$); +#1481=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_19','Cross-country skiing',#1478,$,$); +#1482=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_20','Curling',#1478,$,$); +#1483=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_32','Freestyle skiing',#1478,$,$); +#1484=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_40','Ice skating',#1478,$,$); +#1485=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_41','Ice hockey',#1478,$,$); +#1486=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_49','Luge',#1478,$,$); +#1487=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_76','Short track speed skating',#1478,$,$); +#1488=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_77','Skeleton sledding',#1478,$,$); +#1489=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_78','Skiing',#1478,$,$); +#1490=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_79','Ski jumping',#1478,$,$); +#1491=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_80','Snowboarding',#1478,$,$); +#1492=IFCCLASSIFICATIONREFERENCE($,'Ac_42_95_83','Speed skating',#1478,$,$); +#1493=IFCCLASSIFICATIONREFERENCE($,'Ac_45','Residential activities',#852,$,$); +#1494=IFCCLASSIFICATIONREFERENCE($,'Ac_45_30','External living activities',#1493,$,$); +#1495=IFCCLASSIFICATIONREFERENCE($,'Ac_45_30_11','Camping',#1494,$,$); +#1496=IFCCLASSIFICATIONREFERENCE($,'Ac_45_30_12','Caravanning',#1494,$,$); +#1497=IFCCLASSIFICATIONREFERENCE($,'Ac_45_30_33','Gardening',#1494,$,$); +#1498=IFCCLASSIFICATIONREFERENCE($,'Ac_45_45','Living activities',#1493,$,$); +#1499=IFCCLASSIFICATIONREFERENCE($,'Ac_45_45_14','Communal socializing',#1498,$,$); +#1500=IFCCLASSIFICATIONREFERENCE($,'Ac_45_45_22','Dining',#1498,$,$); +#1501=IFCCLASSIFICATIONREFERENCE($,'Ac_45_45_79','Sleeping',#1498,$,$); +#1502=IFCCLASSIFICATIONREFERENCE($,'Ac_45_70','Residential support activities',#1493,$,$); +#1503=IFCCLASSIFICATIONREFERENCE($,'Ac_45_70_16','Concierge servicing',#1502,$,$); +#1504=IFCCLASSIFICATIONREFERENCE($,'Ac_45_70_93','Utility activities',#1502,$,$); +#1505=IFCCLASSIFICATIONREFERENCE($,'Ac_50','Waste disposal activities',#852,$,$); +#1506=IFCCLASSIFICATIONREFERENCE($,'Ac_50_40','Dry waste collecting',#1505,$,$); +#1507=IFCCLASSIFICATIONREFERENCE($,'Ac_50_40_72','Refuse storing',#1506,$,$); +#1508=IFCCLASSIFICATIONREFERENCE($,'Ac_50_40_78','Scrapping',#1506,$,$); +#1509=IFCCLASSIFICATIONREFERENCE($,'Ac_55','Piped supply activities',#852,$,$); +#1510=IFCCLASSIFICATIONREFERENCE($,'Ac_55_60','Piped supply installations testing',#1509,$,$); +#1511=IFCCLASSIFICATIONREFERENCE($,'Ac_55_60_30','Fire suppression installation testing',#1510,$,$); +#1512=IFCCLASSIFICATIONREFERENCE($,'Ac_55_60_68','Public health installation testing',#1510,$,$); +#1513=IFCCLASSIFICATIONREFERENCE($,'Ac_55_60_96','Water supply installation testing',#1510,$,$); +#1514=IFCCLASSIFICATIONREFERENCE($,'Ac_55_65','Piped supply systems commissioning',#1509,$,$); +#1515=IFCCLASSIFICATIONREFERENCE($,'Ac_55_65_31','Fire suppression systems commissioning',#1514,$,$); +#1516=IFCCLASSIFICATIONREFERENCE($,'Ac_55_65_96','Water supply systems commissioning',#1514,$,$); +#1517=IFCCLASSIFICATIONREFERENCE($,'Ac_60','Heating, cooling and refrigeration activities',#852,$,$); +#1518=IFCCLASSIFICATIONREFERENCE($,'Ac_60_60','Heating and chilled water installations testing',#1517,$,$); +#1519=IFCCLASSIFICATIONREFERENCE($,'Ac_60_60_13','Chilled water installations testing',#1518,$,$); +#1520=IFCCLASSIFICATIONREFERENCE($,'Ac_60_60_36','Heating installations testing',#1518,$,$); +#1521=IFCCLASSIFICATIONREFERENCE($,'Ac_60_60_63','Heating and cooling plant and equipment testing',#1518,$,$); +#1522=IFCCLASSIFICATIONREFERENCE($,'Ac_60_60_65','Pressure testing pipework',#1518,$,$); +#1523=IFCCLASSIFICATIONREFERENCE($,'Ac_60_65','Heating and cooling systems and plant commissioning',#1517,$,$); +#1524=IFCCLASSIFICATIONREFERENCE($,'Ac_60_65_06','Boilers commissioning',#1523,$,$); +#1525=IFCCLASSIFICATIONREFERENCE($,'Ac_60_65_13','Chilled water systems commissioning',#1523,$,$); +#1526=IFCCLASSIFICATIONREFERENCE($,'Ac_60_65_36','Heating systems commissioning',#1523,$,$); +#1527=IFCCLASSIFICATIONREFERENCE($,'Ac_60_65_70','Refrigeration plant and equipment commissioning',#1523,$,$); +#1528=IFCCLASSIFICATIONREFERENCE($,'Ac_65','Ventilation and air conditioning activities',#852,$,$); +#1529=IFCCLASSIFICATIONREFERENCE($,'Ac_65_60','Ventilation and air conditioning installation testing',#1528,$,$); +#1530=IFCCLASSIFICATIONREFERENCE($,'Ac_65_60_01','Air conditioning plant and equipment testing',#1529,$,$); +#1531=IFCCLASSIFICATIONREFERENCE($,'Ac_65_60_02','Air supply installations testing',#1529,$,$); +#1532=IFCCLASSIFICATIONREFERENCE($,'Ac_65_60_63','Ventilation plant and equipment testing',#1529,$,$); +#1533=IFCCLASSIFICATIONREFERENCE($,'Ac_65_65','Ventilation and air conditioning systems commissioning',#1528,$,$); +#1534=IFCCLASSIFICATIONREFERENCE($,'Ac_65_65_02','Air systems commissioning',#1533,$,$); +#1535=IFCCLASSIFICATIONREFERENCE($,'Ac_70','Electrical activities',#852,$,$); +#1536=IFCCLASSIFICATIONREFERENCE($,'Ac_70_60','Electrical installations testing',#1535,$,$); +#1537=IFCCLASSIFICATIONREFERENCE($,'Ac_70_60_28','Emergency lighting installations testing',#1536,$,$); +#1538=IFCCLASSIFICATIONREFERENCE($,'Ac_70_60_37','High voltage electrical installations testing',#1536,$,$); +#1539=IFCCLASSIFICATIONREFERENCE($,'Ac_70_60_46','Lighting installations testing',#1536,$,$); +#1540=IFCCLASSIFICATIONREFERENCE($,'Ac_70_60_47','Lightning protection installations testing',#1536,$,$); +#1541=IFCCLASSIFICATIONREFERENCE($,'Ac_70_60_49','Low voltage electrical installation testing and inspecting',#1536,$,$); +#1542=IFCCLASSIFICATIONREFERENCE($,'Ac_70_65','Electrical systems commissioning',#1535,$,$); +#1543=IFCCLASSIFICATIONREFERENCE($,'Ac_70_65_46','Lighting systems commissioning',#1542,$,$); +#1544=IFCCLASSIFICATIONREFERENCE($,'Ac_75','Communications, security, safety and protection activities',#852,$,$); +#1545=IFCCLASSIFICATIONREFERENCE($,'Ac_75_60','Communications, security, safety and protection installations testing',#1544,$,$); +#1546=IFCCLASSIFICATIONREFERENCE($,'Ac_75_60_01','Access control systems testing',#1545,$,$); +#1547=IFCCLASSIFICATIONREFERENCE($,'Ac_75_60_04','Audio visual systems testing',#1545,$,$); +#1548=IFCCLASSIFICATIONREFERENCE($,'Ac_75_60_15','Control systems testing',#1545,$,$); +#1549=IFCCLASSIFICATIONREFERENCE($,'Ac_75_60_30','Fire protection installation testing',#1545,$,$); +#1550=IFCCLASSIFICATIONREFERENCE($,'Ac_75_60_42','Intruder alarm systems testing',#1545,$,$); +#1551=IFCCLASSIFICATIONREFERENCE($,'Ac_75_60_47','Lifts testing',#1545,$,$); +#1552=IFCCLASSIFICATIONREFERENCE($,'Ac_75_60_80','Security systems testing',#1545,$,$); +#1553=IFCCLASSIFICATIONREFERENCE($,'Ac_75_60_85','Surveillance equipment installations testing',#1545,$,$); +#1554=IFCCLASSIFICATIONREFERENCE($,'Ac_75_60_92','Telecommunications systems testing',#1545,$,$); +#1555=IFCCLASSIFICATIONREFERENCE($,'Ac_75_65','Communications, security, safety and protection systems commissioning',#1544,$,$); +#1556=IFCCLASSIFICATIONREFERENCE($,'Ac_75_65_01','Access control systems commissioning',#1555,$,$); +#1557=IFCCLASSIFICATIONREFERENCE($,'Ac_75_65_04','Audio visual systems commissioning',#1555,$,$); +#1558=IFCCLASSIFICATIONREFERENCE($,'Ac_75_65_15','Control systems commissioning',#1555,$,$); +#1559=IFCCLASSIFICATIONREFERENCE($,'Ac_75_65_30','Fire alarm systems commissioning',#1555,$,$); +#1560=IFCCLASSIFICATIONREFERENCE($,'Ac_75_65_42','Intruder alarm systems commissioning',#1555,$,$); +#1561=IFCCLASSIFICATIONREFERENCE($,'Ac_75_65_47','Lifts commissioning',#1555,$,$); +#1562=IFCCLASSIFICATIONREFERENCE($,'Ac_75_65_80','Security systems commissioning',#1555,$,$); +#1563=IFCCLASSIFICATIONREFERENCE($,'Ac_75_65_85','Surveillance systems commissioning',#1555,$,$); +#1564=IFCCLASSIFICATIONREFERENCE($,'Ac_75_65_92','Telecommunications systems commissioning',#1555,$,$); +#1565=IFCCLASSIFICATIONREFERENCE($,'Ac_80','Transport activities',#852,$,$); +#1566=IFCCLASSIFICATIONREFERENCE($,'Ac_80_00','Accommodation works activities',#1565,$,$); +#1567=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05','Aerospace ground activities',#1565,$,$); +#1568=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_02','Aeroplane landing',#1567,$,$); +#1569=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_03','Aeroplane take-off',#1567,$,$); +#1570=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_05','Aircraft manoeuvring',#1567,$,$); +#1571=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_06','Aircraft manoeuvring buffering',#1567,$,$); +#1572=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_07','Aircraft standing',#1567,$,$); +#1573=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_09','Airport controlling',#1567,$,$); +#1574=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_33','Glider landing',#1567,$,$); +#1575=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_34','Glider take-off',#1567,$,$); +#1576=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_36','Hang gliding landing',#1567,$,$); +#1577=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_37','Hang gliding take-off',#1567,$,$); +#1578=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_38','Helicopter landing',#1567,$,$); +#1579=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_39','Helicopter take-off',#1567,$,$); +#1580=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_82','Spacecraft landing',#1567,$,$); +#1581=IFCCLASSIFICATIONREFERENCE($,'Ac_80_05_84','Spacecraft take-off',#1567,$,$); +#1582=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10','Loading and embarkation activities',#1565,$,$); +#1583=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_04','Aircraft fuelling',#1582,$,$); +#1584=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_06','Baggage claiming',#1582,$,$); +#1585=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_07','Baggage handling',#1582,$,$); +#1586=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_08','Baggage loading',#1582,$,$); +#1587=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_12','Cargo handling',#1582,$,$); +#1588=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_13','Cargo loading',#1582,$,$); +#1589=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_20','Customs controlling',#1582,$,$); +#1590=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_60','Passenger arriving',#1582,$,$); +#1591=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_61','Passenger departing',#1582,$,$); +#1592=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_62','Passenger disembarking',#1582,$,$); +#1593=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_63','Passenger embarking',#1582,$,$); +#1594=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_64','Passenger gathering',#1582,$,$); +#1595=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_65','Passport controlling',#1582,$,$); +#1596=IFCCLASSIFICATIONREFERENCE($,'Ac_80_10_86','Ticketing',#1582,$,$); +#1597=IFCCLASSIFICATIONREFERENCE($,'Ac_80_15','Aerospace maintenance activities',#1565,$,$); +#1598=IFCCLASSIFICATIONREFERENCE($,'Ac_80_15_01','Aircraft cleaning',#1597,$,$); +#1599=IFCCLASSIFICATIONREFERENCE($,'Ac_80_15_02','Aircraft maintaining',#1597,$,$); +#1600=IFCCLASSIFICATIONREFERENCE($,'Ac_80_15_04','Aircraft repairing',#1597,$,$); +#1601=IFCCLASSIFICATIONREFERENCE($,'Ac_80_15_79','Spacecraft cleaning',#1597,$,$); +#1602=IFCCLASSIFICATIONREFERENCE($,'Ac_80_15_80','Spacecraft maintaining',#1597,$,$); +#1603=IFCCLASSIFICATIONREFERENCE($,'Ac_80_15_81','Spacecraft preparing',#1597,$,$); +#1604=IFCCLASSIFICATIONREFERENCE($,'Ac_80_15_82','Spacecraft repairing',#1597,$,$); +#1605=IFCCLASSIFICATIONREFERENCE($,'Ac_80_20','Cable way activities',#1565,$,$); +#1606=IFCCLASSIFICATIONREFERENCE($,'Ac_80_20_13','Cableway travelling',#1605,$,$); +#1607=IFCCLASSIFICATIONREFERENCE($,'Ac_80_30','Cable transport storage and maintenance activities',#1565,$,$); +#1608=IFCCLASSIFICATIONREFERENCE($,'Ac_80_30_34','Gondola repair and cleaning',#1607,$,$); +#1609=IFCCLASSIFICATIONREFERENCE($,'Ac_80_30_35','Gondola storing',#1607,$,$); +#1610=IFCCLASSIFICATIONREFERENCE($,'Ac_80_35','Highway activities',#1565,$,$); +#1611=IFCCLASSIFICATIONREFERENCE($,'Ac_80_35_08','Bus manoeuvring',#1610,$,$); +#1612=IFCCLASSIFICATIONREFERENCE($,'Ac_80_35_12','Car manoeuvring',#1610,$,$); +#1613=IFCCLASSIFICATIONREFERENCE($,'Ac_80_35_16','Carriageway separating',#1610,$,$); +#1614=IFCCLASSIFICATIONREFERENCE($,'Ac_80_35_24','Driving',#1610,$,$); +#1615=IFCCLASSIFICATIONREFERENCE($,'Ac_80_35_46','Laying-by and passing',#1610,$,$); +#1616=IFCCLASSIFICATIONREFERENCE($,'Ac_80_35_63','Pedestrian crossing',#1610,$,$); +#1617=IFCCLASSIFICATIONREFERENCE($,'Ac_80_35_64','Pedestrian standing',#1610,$,$); +#1618=IFCCLASSIFICATIONREFERENCE($,'Ac_80_35_70','Railway crossing',#1610,$,$); +#1619=IFCCLASSIFICATIONREFERENCE($,'Ac_80_35_73','Road buffering',#1610,$,$); +#1620=IFCCLASSIFICATIONREFERENCE($,'Ac_80_35_90','Truck manoeuvring',#1610,$,$); +#1621=IFCCLASSIFICATIONREFERENCE($,'Ac_80_35_95','Vehicle manoeuvring',#1610,$,$); +#1622=IFCCLASSIFICATIONREFERENCE($,'Ac_80_45','Highway storage and maintenance activities',#1565,$,$); +#1623=IFCCLASSIFICATIONREFERENCE($,'Ac_80_45_09','Bus standing',#1622,$,$); +#1624=IFCCLASSIFICATIONREFERENCE($,'Ac_80_45_40','Indoor vehicle parking',#1622,$,$); +#1625=IFCCLASSIFICATIONREFERENCE($,'Ac_80_45_59','Outdoor vehicle parking',#1622,$,$); +#1626=IFCCLASSIFICATIONREFERENCE($,'Ac_80_45_91','Truck standing',#1622,$,$); +#1627=IFCCLASSIFICATIONREFERENCE($,'Ac_80_45_94','Vehicle fuelling and charging',#1622,$,$); +#1628=IFCCLASSIFICATIONREFERENCE($,'Ac_80_45_95','Vehicle inspecting',#1622,$,$); +#1629=IFCCLASSIFICATIONREFERENCE($,'Ac_80_45_96','Vehicle servicing',#1622,$,$); +#1630=IFCCLASSIFICATIONREFERENCE($,'Ac_80_50','Railway activities',#1565,$,$); +#1631=IFCCLASSIFICATIONREFERENCE($,'Ac_80_50_50','Marshalling',#1630,$,$); +#1632=IFCCLASSIFICATIONREFERENCE($,'Ac_80_50_70','Rail over passing',#1630,$,$); +#1633=IFCCLASSIFICATIONREFERENCE($,'Ac_80_50_71','Rail signal controlling',#1630,$,$); +#1634=IFCCLASSIFICATIONREFERENCE($,'Ac_80_50_73','Railway track buffering',#1630,$,$); +#1635=IFCCLASSIFICATIONREFERENCE($,'Ac_80_50_75','Railway travel',#1630,$,$); +#1636=IFCCLASSIFICATIONREFERENCE($,'Ac_80_50_76','Rail under passing',#1630,$,$); +#1637=IFCCLASSIFICATIONREFERENCE($,'Ac_80_50_90','Train stopping',#1630,$,$); +#1638=IFCCLASSIFICATIONREFERENCE($,'Ac_80_60','Rail storage and maintenance activities',#1565,$,$); +#1639=IFCCLASSIFICATIONREFERENCE($,'Ac_80_60_11','Carriage cleaning',#1638,$,$); +#1640=IFCCLASSIFICATIONREFERENCE($,'Ac_80_60_26','Engine fuelling',#1638,$,$); +#1641=IFCCLASSIFICATIONREFERENCE($,'Ac_80_60_27','Engine inspecting',#1638,$,$); +#1642=IFCCLASSIFICATIONREFERENCE($,'Ac_80_60_28','Engine servicing',#1638,$,$); +#1643=IFCCLASSIFICATIONREFERENCE($,'Ac_80_60_29','Engine washing',#1638,$,$); +#1644=IFCCLASSIFICATIONREFERENCE($,'Ac_80_60_70','Rail repairing',#1638,$,$); +#1645=IFCCLASSIFICATIONREFERENCE($,'Ac_80_70','Marine way and waterway activities',#1565,$,$); +#1646=IFCCLASSIFICATIONREFERENCE($,'Ac_80_70_11','Canal level changing',#1645,$,$); +#1647=IFCCLASSIFICATIONREFERENCE($,'Ac_80_70_12','Canal travelling',#1645,$,$); +#1648=IFCCLASSIFICATIONREFERENCE($,'Ac_80_70_37','Harbour level changing',#1645,$,$); +#1649=IFCCLASSIFICATIONREFERENCE($,'Ac_80_94','Bridge function',#1565,$,$); +#1650=IFCCLASSIFICATIONREFERENCE($,'Ac_80_94_41','Bridge inspecting',#1649,$,$); +#1651=IFCCLASSIFICATIONREFERENCE($,'Ac_80_94_60','Passing over a bridge',#1649,$,$); +#1652=IFCCLASSIFICATIONREFERENCE($,'Ac_80_94_90','Passing under a bridge',#1649,$,$); +#1653=IFCCLASSIFICATIONREFERENCE($,'Ac_85','Operation and maintenance activities',#852,$,$); +#1654=IFCCLASSIFICATIONREFERENCE($,'Ac_85_10','Barrier and fence maintenance activities',#1653,$,$); +#1655=IFCCLASSIFICATIONREFERENCE($,'Ac_85_10_06','Barrier maintenance',#1654,$,$); +#1656=IFCCLASSIFICATIONREFERENCE($,'Ac_85_10_30','Fencing maintenance',#1654,$,$); +#1657=IFCCLASSIFICATIONREFERENCE($,'Ac_85_10_45','Kerbs and channels maintenance',#1654,$,$); +#1658=IFCCLASSIFICATIONREFERENCE($,'Ac_85_10_95','Vehicle restraint systems maintenance',#1654,$,$); +#1659=IFCCLASSIFICATIONREFERENCE($,'Ac_85_30','Flora maintenance activities',#1653,$,$); +#1660=IFCCLASSIFICATIONREFERENCE($,'Ac_85_30_01','Amenity grass maintenance',#1659,$,$); +#1661=IFCCLASSIFICATIONREFERENCE($,'Ac_85_30_02','Amenity planting maintenance',#1659,$,$); +#1662=IFCCLASSIFICATIONREFERENCE($,'Ac_85_30_04','Aquatic and wetland planting maintenance',#1659,$,$); +#1663=IFCCLASSIFICATIONREFERENCE($,'Ac_85_30_28','External container planting maintenance',#1659,$,$); +#1664=IFCCLASSIFICATIONREFERENCE($,'Ac_85_30_30','Forestry maintenance',#1659,$,$); +#1665=IFCCLASSIFICATIONREFERENCE($,'Ac_85_30_37','Hedgerow maintenance',#1659,$,$); +#1666=IFCCLASSIFICATIONREFERENCE($,'Ac_85_30_40','Internal container planting maintenance',#1659,$,$); +#1667=IFCCLASSIFICATIONREFERENCE($,'Ac_85_30_47','Living roof maintenance',#1659,$,$); +#1668=IFCCLASSIFICATIONREFERENCE($,'Ac_85_30_50','Meadow grass maintenance',#1659,$,$); +#1669=IFCCLASSIFICATIONREFERENCE($,'Ac_85_30_80','Sports turf maintenance',#1659,$,$); +#1670=IFCCLASSIFICATIONREFERENCE($,'Ac_85_30_95','Vegetation control maintenance',#1659,$,$); +#1671=IFCCLASSIFICATIONREFERENCE($,'Ac_85_30_97','Wildflowers meadow maintenance',#1659,$,$); +#1672=IFCCLASSIFICATIONREFERENCE($,'Ac_85_50','Marine maintenance activities',#1653,$,$); +#1673=IFCCLASSIFICATIONREFERENCE($,'Ac_85_50_24','Dredging',#1672,$,$); +#1674=IFCCLASSIFICATIONREFERENCE($,'Ac_85_60','Paving maintenance activities',#1653,$,$); +#1675=IFCCLASSIFICATIONREFERENCE($,'Ac_85_60_02','Asphalt paving maintenance',#1674,$,$); +#1676=IFCCLASSIFICATIONREFERENCE($,'Ac_85_60_04','Asphalt sports paving maintenance',#1674,$,$); +#1677=IFCCLASSIFICATIONREFERENCE($,'Ac_85_60_10','Bound aggregate paving maintenance',#1674,$,$); +#1678=IFCCLASSIFICATIONREFERENCE($,'Ac_85_60_50','Mat and sheet paving maintenance',#1674,$,$); +#1679=IFCCLASSIFICATIONREFERENCE($,'Ac_85_60_80','Sport or play paving maintenance',#1674,$,$); +#1680=IFCCLASSIFICATIONREFERENCE($,'Ac_85_60_82','Sports or play unbound paving maintenance',#1674,$,$); +#1681=IFCCLASSIFICATIONREFERENCE($,'Ac_85_60_92','Unbound paving maintenance',#1674,$,$); +#1682=IFCCLASSIFICATIONREFERENCE($,'Ac_85_60_93','Unit paving maintenance',#1674,$,$); +#1683=IFCCLASSIFICATIONREFERENCE($,'Ac_85_65','Plant and controls operating',#1653,$,$); +#1684=IFCCLASSIFICATIONREFERENCE($,'Ac_85_65_08','Boiler operating',#1683,$,$); +#1685=IFCCLASSIFICATIONREFERENCE($,'Ac_85_65_15','Controlling',#1683,$,$); +#1686=IFCCLASSIFICATIONREFERENCE($,'Ac_85_65_26','Electrical switching',#1683,$,$); +#1687=IFCCLASSIFICATIONREFERENCE($,'Ac_85_65_27','Equipment operating',#1683,$,$); +#1688=IFCCLASSIFICATIONREFERENCE($,'Ac_85_65_32','Furnace operating',#1683,$,$); +#1689=IFCCLASSIFICATIONREFERENCE($,'Ac_85_65_42','Incinerating',#1683,$,$); +#1690=IFCCLASSIFICATIONREFERENCE($,'Ac_85_65_48','Lift machine operating',#1683,$,$); +#1691=IFCCLASSIFICATIONREFERENCE($,'Ac_85_65_50','Meter checking',#1683,$,$); +#1692=IFCCLASSIFICATIONREFERENCE($,'Ac_85_65_64','Plant operating',#1683,$,$); +#1693=IFCCLASSIFICATIONREFERENCE($,'Ac_85_65_77','Server operating',#1683,$,$); +#1694=IFCCLASSIFICATIONREFERENCE($,'Ac_85_65_90','Transformer operating',#1683,$,$); +#1695=IFCCLASSIFICATIONREFERENCE($,'Ac_85_70','Retrospective application activities',#1653,$,$); +#1696=IFCCLASSIFICATIONREFERENCE($,'Ac_85_70_40','Insulating and waterproofing retrofitted living roofs',#1695,$,$); +#1697=IFCCLASSIFICATIONREFERENCE($,'Ac_85_70_70','Retrospective applying of fire retardant treatment',#1695,$,$); +#1698=IFCCLASSIFICATIONREFERENCE($,'Ac_85_70_75','Retrospective applying of preservative treatment',#1695,$,$); +#1699=IFCCLASSIFICATIONREFERENCE($,'Ac_90','Circulation and plant activities',#852,$,$); +#1700=IFCCLASSIFICATIONREFERENCE($,'Ac_90_10','Circulation activities',#1699,$,$); +#1701=IFCCLASSIFICATIONREFERENCE($,'Ac_90_10_02','Air blocking',#1700,$,$); +#1702=IFCCLASSIFICATIONREFERENCE($,'Ac_90_10_14','Circulating between rooms',#1700,$,$); +#1703=IFCCLASSIFICATIONREFERENCE($,'Ac_90_10_16','Covered walking',#1700,$,$); +#1704=IFCCLASSIFICATIONREFERENCE($,'Ac_90_10_24','Dropping-off and collecting',#1700,$,$); +#1705=IFCCLASSIFICATIONREFERENCE($,'Ac_90_10_27','Entering and exiting',#1700,$,$); +#1706=IFCCLASSIFICATIONREFERENCE($,'Ac_90_10_34','Goods conveying',#1700,$,$); +#1707=IFCCLASSIFICATIONREFERENCE($,'Ac_90_10_49','Lift stopping and calling',#1700,$,$); +#1708=IFCCLASSIFICATIONREFERENCE($,'Ac_90_10_50','Lift travelling',#1700,$,$); +#1709=IFCCLASSIFICATIONREFERENCE($,'Ac_90_10_77','Sheltering',#1700,$,$); +#1710=IFCCLASSIFICATIONREFERENCE($,'Ac_90_10_78','Shoppers moving and circulation',#1700,$,$); +#1711=IFCCLASSIFICATIONREFERENCE($,'Ac_90_10_93','Uncovered walking',#1700,$,$); +#1712=IFCCLASSIFICATIONREFERENCE($,'Ac_90_10_96','Wheelchair travelling',#1700,$,$); +#1713=IFCCLASSIFICATIONREFERENCE($,'Ac_90_20','Common activities',#1699,$,$); +#1714=IFCCLASSIFICATIONREFERENCE($,'Ac_90_20_09','Briefing',#1713,$,$); +#1715=IFCCLASSIFICATIONREFERENCE($,'Ac_90_20_13','Changing',#1713,$,$); +#1716=IFCCLASSIFICATIONREFERENCE($,'Ac_90_20_42','Interviewing',#1713,$,$); +#1717=IFCCLASSIFICATIONREFERENCE($,'Ac_90_20_69','Queuing',#1713,$,$); +#1718=IFCCLASSIFICATIONREFERENCE($,'Ac_90_20_72','Resting',#1713,$,$); +#1719=IFCCLASSIFICATIONREFERENCE($,'Ac_90_20_82','Spectator seating',#1713,$,$); +#1720=IFCCLASSIFICATIONREFERENCE($,'Ac_90_20_83','Spectator standing',#1713,$,$); +#1721=IFCCLASSIFICATIONREFERENCE($,'Ac_90_20_96','Waiting',#1713,$,$); +#1722=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50','Storing activities',#1699,$,$); +#1723=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_02','Aircraft storing',#1722,$,$); +#1724=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_04','Arms storing',#1722,$,$); +#1725=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_06','Baggage storing',#1722,$,$); +#1726=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_07','Beer storing',#1722,$,$); +#1727=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_09','Blood storing',#1722,$,$); +#1728=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_10','Boat storing',#1722,$,$); +#1729=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_11','Cargo storing',#1722,$,$); +#1730=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_13','Chemicals storing',#1722,$,$); +#1731=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_14','Clothes storing',#1722,$,$); +#1732=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_15','Cold storing',#1722,$,$); +#1733=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_24','Dry waste storing',#1722,$,$); +#1734=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_25','Evidence storing',#1722,$,$); +#1735=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_26','Explosives storing',#1722,$,$); +#1736=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_28','Feed storing',#1722,$,$); +#1737=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_29','Flammable chemicals storing',#1722,$,$); +#1738=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_30','Food storing',#1722,$,$); +#1739=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_32','Fuel storing',#1722,$,$); +#1740=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_34','Gas storing',#1722,$,$); +#1741=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_35','General storing',#1722,$,$); +#1742=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_36','Glider storing',#1722,$,$); +#1743=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_37','Goods storing',#1722,$,$); +#1744=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_39','Grain storing',#1722,$,$); +#1745=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_41','Hang glider storing',#1722,$,$); +#1746=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_42','Hazardous waste storing',#1722,$,$); +#1747=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_44','Helicoptor storing',#1722,$,$); +#1748=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_47','Left luggage storing',#1722,$,$); +#1749=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_52','Medical records storing',#1722,$,$); +#1750=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_53','Mineral storing',#1722,$,$); +#1751=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_58','Oil storing',#1722,$,$); +#1752=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_59','Outdoor storing',#1722,$,$); +#1753=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_65','Pharmacy storing',#1722,$,$); +#1754=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_70','Raw materials storing',#1722,$,$); +#1755=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_75','Scientific equipment storing',#1722,$,$); +#1756=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_77','Secure storing',#1722,$,$); +#1757=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_80','Solid fuel storing',#1722,$,$); +#1758=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_84','Storage of human remains',#1722,$,$); +#1759=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_91','Vehicle storing',#1722,$,$); +#1760=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_92','Walk-in clothes storing',#1722,$,$); +#1761=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_93','Waste gas storing',#1722,$,$); +#1762=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_94','Waste liquids storing',#1722,$,$); +#1763=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_95','Waste solids storing',#1722,$,$); +#1764=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_96','Water storing',#1722,$,$); +#1765=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_97','Wet waste storing',#1722,$,$); +#1766=IFCCLASSIFICATIONREFERENCE($,'Ac_90_50_98','Wine storing',#1722,$,$); +#1767=IFCCLASSIFICATIONREFERENCE($,'SL','Spaces/ locations',#2,$,$); +#1768=IFCCLASSIFICATIONREFERENCE($,'SL_20','Administrative, commercial and protective service spaces',#1767,$,$); +#1769=IFCCLASSIFICATIONREFERENCE($,'SL_20_10','Legislative spaces',#1768,$,$); +#1770=IFCCLASSIFICATIONREFERENCE($,'SL_20_10_47','Legislative chambers',#1769,$,$); +#1771=IFCCLASSIFICATIONREFERENCE($,'SL_20_10_49','Legislative chamber viewing galleries',#1769,$,$); +#1772=IFCCLASSIFICATIONREFERENCE($,'SL_20_15','Administrative spaces',#1768,$,$); +#1773=IFCCLASSIFICATIONREFERENCE($,'SL_20_15_27','Enclosed offices',#1772,$,$); +#1774=IFCCLASSIFICATIONREFERENCE($,'SL_20_15_50','Meeting rooms',#1772,$,$); +#1775=IFCCLASSIFICATIONREFERENCE($,'SL_20_15_59','Offices',#1772,$,$); +#1776=IFCCLASSIFICATIONREFERENCE($,'SL_20_15_61','Open-plan offices',#1772,$,$); +#1777=IFCCLASSIFICATIONREFERENCE($,'SL_20_15_71','Reception areas',#1772,$,$); +#1778=IFCCLASSIFICATIONREFERENCE($,'SL_20_45','Motor vehicle maintenance and fuelling spaces',#1768,$,$); +#1779=IFCCLASSIFICATIONREFERENCE($,'SL_20_45_27','Electric motor vehicle charging points',#1778,$,$); +#1780=IFCCLASSIFICATIONREFERENCE($,'SL_20_45_29','Fuel filling station air and water points',#1778,$,$); +#1781=IFCCLASSIFICATIONREFERENCE($,'SL_20_45_30','Fuel filling station forecourts',#1778,$,$); +#1782=IFCCLASSIFICATIONREFERENCE($,'SL_20_45_31','Fuel filling station tanks areas',#1778,$,$); +#1783=IFCCLASSIFICATIONREFERENCE($,'SL_20_45_53','Motor vehicle maintenance areas',#1778,$,$); +#1784=IFCCLASSIFICATIONREFERENCE($,'SL_20_45_95','Vehicle inspection pits',#1778,$,$); +#1785=IFCCLASSIFICATIONREFERENCE($,'SL_20_45_96','Vehicle servicing areas',#1778,$,$); +#1786=IFCCLASSIFICATIONREFERENCE($,'SL_20_50','Commercial spaces',#1768,$,$); +#1787=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_03','Ambient wholesale spaces',#1786,$,$); +#1788=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_05','Auction rooms',#1786,$,$); +#1789=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_10','Beauty salons',#1786,$,$); +#1790=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_12','Checkout points',#1786,$,$); +#1791=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_22','Department store shop floors',#1786,$,$); +#1792=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_29','Financial and professional services outlets',#1786,$,$); +#1793=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_30','Fitting rooms',#1786,$,$); +#1794=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_32','Food and drink outlets',#1786,$,$); +#1795=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_36','Hair and beauty salons',#1786,$,$); +#1796=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_37','Hair salons',#1786,$,$); +#1797=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_47','Livestock auction rooms',#1786,$,$); +#1798=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_51','Market stalls',#1786,$,$); +#1799=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_55','Motor vehicle showrooms',#1786,$,$); +#1800=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_70','Refrigerated wholesale spaces',#1786,$,$); +#1801=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_72','Retail kiosks',#1786,$,$); +#1802=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_85','Supermarket shop floors',#1786,$,$); +#1803=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_86','Tan spray booths',#1786,$,$); +#1804=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_87','Tattoo and piercing parlours',#1786,$,$); +#1805=IFCCLASSIFICATIONREFERENCE($,'SL_20_50_96','Waste and scrap yards',#1786,$,$); +#1806=IFCCLASSIFICATIONREFERENCE($,'SL_20_55','Postal communications spaces',#1768,$,$); +#1807=IFCCLASSIFICATIONREFERENCE($,'SL_20_55_45','Letter sorting offices',#1806,$,$); +#1808=IFCCLASSIFICATIONREFERENCE($,'SL_20_55_50','Mail order sorting and despatch facilities',#1806,$,$); +#1809=IFCCLASSIFICATIONREFERENCE($,'SL_20_55_60','Parcel sorting offices',#1806,$,$); +#1810=IFCCLASSIFICATIONREFERENCE($,'SL_20_55_65','Post rooms',#1806,$,$); +#1811=IFCCLASSIFICATIONREFERENCE($,'SL_20_60','Military protective spaces',#1768,$,$); +#1812=IFCCLASSIFICATIONREFERENCE($,'SL_20_60_08','Bombardment shelters',#1811,$,$); +#1813=IFCCLASSIFICATIONREFERENCE($,'SL_20_60_27','Emergency shelters',#1811,$,$); +#1814=IFCCLASSIFICATIONREFERENCE($,'SL_20_60_70','Radiation protection shelters',#1811,$,$); +#1815=IFCCLASSIFICATIONREFERENCE($,'SL_20_60_98','War emergency centres',#1811,$,$); +#1816=IFCCLASSIFICATIONREFERENCE($,'SL_20_62','Parade spaces',#1768,$,$); +#1817=IFCCLASSIFICATIONREFERENCE($,'SL_20_62_65','Parade grounds',#1816,$,$); +#1818=IFCCLASSIFICATIONREFERENCE($,'SL_20_65','Law enforcement spaces',#1768,$,$); +#1819=IFCCLASSIFICATIONREFERENCE($,'SL_20_65_15','Command and control spaces',#1818,$,$); +#1820=IFCCLASSIFICATIONREFERENCE($,'SL_20_65_28','Examination rooms',#1818,$,$); +#1821=IFCCLASSIFICATIONREFERENCE($,'SL_20_65_39','Identification control rooms',#1818,$,$); +#1822=IFCCLASSIFICATIONREFERENCE($,'SL_20_65_40','Identification suites',#1818,$,$); +#1823=IFCCLASSIFICATIONREFERENCE($,'SL_20_65_41','Interview monitoring rooms',#1818,$,$); +#1824=IFCCLASSIFICATIONREFERENCE($,'SL_20_65_42','Interview rooms',#1818,$,$); +#1825=IFCCLASSIFICATIONREFERENCE($,'SL_20_65_65','Police boxes',#1818,$,$); +#1826=IFCCLASSIFICATIONREFERENCE($,'SL_20_70','Judicial spaces',#1768,$,$); +#1827=IFCCLASSIFICATIONREFERENCE($,'SL_20_70_15','Court rooms',#1826,$,$); +#1828=IFCCLASSIFICATIONREFERENCE($,'SL_20_70_18','Court room viewing galleries',#1826,$,$); +#1829=IFCCLASSIFICATIONREFERENCE($,'SL_20_70_23','Defendant docks',#1826,$,$); +#1830=IFCCLASSIFICATIONREFERENCE($,'SL_20_70_28','Evidence rooms',#1826,$,$); +#1831=IFCCLASSIFICATIONREFERENCE($,'SL_20_70_41','Judicial benches',#1826,$,$); +#1832=IFCCLASSIFICATIONREFERENCE($,'SL_20_70_44','Jury boxes',#1826,$,$); +#1833=IFCCLASSIFICATIONREFERENCE($,'SL_20_70_97','Witness stands',#1826,$,$); +#1834=IFCCLASSIFICATIONREFERENCE($,'SL_20_75','Detention spaces',#1768,$,$); +#1835=IFCCLASSIFICATIONREFERENCE($,'SL_20_75_13','Charge areas',#1834,$,$); +#1836=IFCCLASSIFICATIONREFERENCE($,'SL_20_75_15','Communal inmate dayrooms',#1834,$,$); +#1837=IFCCLASSIFICATIONREFERENCE($,'SL_20_75_22','Detention cells',#1834,$,$); +#1838=IFCCLASSIFICATIONREFERENCE($,'SL_20_75_28','Exercise yards',#1834,$,$); +#1839=IFCCLASSIFICATIONREFERENCE($,'SL_20_75_35','Guard stations',#1834,$,$); +#1840=IFCCLASSIFICATIONREFERENCE($,'SL_20_75_38','Holding cells',#1834,$,$); +#1841=IFCCLASSIFICATIONREFERENCE($,'SL_20_75_75','Sally ports',#1834,$,$); +#1842=IFCCLASSIFICATIONREFERENCE($,'SL_20_75_77','Secure visiting rooms',#1834,$,$); +#1843=IFCCLASSIFICATIONREFERENCE($,'SL_20_75_95','Vehicle impound yards',#1834,$,$); +#1844=IFCCLASSIFICATIONREFERENCE($,'SL_20_80','Weapons training spaces',#1768,$,$); +#1845=IFCCLASSIFICATIONREFERENCE($,'SL_20_80_03','Artillery firing ranges',#1844,$,$); +#1846=IFCCLASSIFICATIONREFERENCE($,'SL_20_80_30','Firing ranges',#1844,$,$); +#1847=IFCCLASSIFICATIONREFERENCE($,'SL_20_80_63','Pistol firing ranges',#1844,$,$); +#1848=IFCCLASSIFICATIONREFERENCE($,'SL_20_80_72','Rifle firing ranges',#1844,$,$); +#1849=IFCCLASSIFICATIONREFERENCE($,'SL_20_85','Security spaces',#1768,$,$); +#1850=IFCCLASSIFICATIONREFERENCE($,'SL_20_85_63','Pedestrian security check points',#1849,$,$); +#1851=IFCCLASSIFICATIONREFERENCE($,'SL_20_85_75','Security control spaces',#1849,$,$); +#1852=IFCCLASSIFICATIONREFERENCE($,'SL_20_85_80','Security offices',#1849,$,$); +#1853=IFCCLASSIFICATIONREFERENCE($,'SL_20_85_95','Vehicular security check points',#1849,$,$); +#1854=IFCCLASSIFICATIONREFERENCE($,'SL_20_90','Fire and incident support spaces',#1768,$,$); +#1855=IFCCLASSIFICATIONREFERENCE($,'SL_20_90_25','Escape stairs',#1854,$,$); +#1856=IFCCLASSIFICATIONREFERENCE($,'SL_20_90_28','Firefighting stairs',#1854,$,$); +#1857=IFCCLASSIFICATIONREFERENCE($,'SL_20_90_30','Fire refuge spaces',#1854,$,$); +#1858=IFCCLASSIFICATIONREFERENCE($,'SL_20_90_31','Fire training spaces',#1854,$,$); +#1859=IFCCLASSIFICATIONREFERENCE($,'SL_20_90_60','Protected escape corridors',#1854,$,$); +#1860=IFCCLASSIFICATIONREFERENCE($,'SL_20_95','Protected zones',#1768,$,$); +#1861=IFCCLASSIFICATIONREFERENCE($,'SL_20_95_20','Detection zones',#1860,$,$); +#1862=IFCCLASSIFICATIONREFERENCE($,'SL_20_95_28','Evacuation zones',#1860,$,$); +#1863=IFCCLASSIFICATIONREFERENCE($,'SL_20_95_30','Fire compartments',#1860,$,$); +#1864=IFCCLASSIFICATIONREFERENCE($,'SL_20_95_32','Fire suppression zones',#1860,$,$); +#1865=IFCCLASSIFICATIONREFERENCE($,'SL_20_95_80','Smoke control zones',#1860,$,$); +#1866=IFCCLASSIFICATIONREFERENCE($,'SL_25','Cultural, educational, scientific and information spaces',#1767,$,$); +#1867=IFCCLASSIFICATIONREFERENCE($,'SL_25_05','Commemoration spaces',#1866,$,$); +#1868=IFCCLASSIFICATIONREFERENCE($,'SL_25_05_72','Commemoration sites',#1867,$,$); +#1869=IFCCLASSIFICATIONREFERENCE($,'SL_25_10','Educational spaces',#1866,$,$); +#1870=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_04','Art classrooms',#1869,$,$); +#1871=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_05','Assembly halls',#1869,$,$); +#1872=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_08','Biology teaching laboratories',#1869,$,$); +#1873=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_13','Chemistry teaching laboratories',#1869,$,$); +#1874=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_14','Classrooms',#1869,$,$); +#1875=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_15','Common rooms',#1869,$,$); +#1876=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_17','Craft classrooms',#1869,$,$); +#1877=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_21','Dance studios',#1869,$,$); +#1878=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_22','Dissection theatres',#1869,$,$); +#1879=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_24','Drama studios',#1869,$,$); +#1880=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_25','Driving skid pans',#1869,$,$); +#1881=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_26','Driving tuition spaces',#1869,$,$); +#1882=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_28','Educational workshops',#1869,$,$); +#1883=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_30','Food technology classrooms',#1869,$,$); +#1884=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_40','Information and communications technology (ICT) laboratories',#1869,$,$); +#1885=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_46','Language laboratories',#1869,$,$); +#1886=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_47','Lecture theatres',#1869,$,$); +#1887=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_55','Music classrooms',#1869,$,$); +#1888=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_66','Physics teaching laboratories',#1869,$,$); +#1889=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_78','Seminar rooms',#1869,$,$); +#1890=IFCCLASSIFICATIONREFERENCE($,'SL_25_10_84','Study rooms',#1869,$,$); +#1891=IFCCLASSIFICATIONREFERENCE($,'SL_25_20','Design spaces',#1866,$,$); +#1892=IFCCLASSIFICATIONREFERENCE($,'SL_25_20_04','Artists'' studios',#1891,$,$); +#1893=IFCCLASSIFICATIONREFERENCE($,'SL_25_20_18','Creative art studios',#1891,$,$); +#1894=IFCCLASSIFICATIONREFERENCE($,'SL_25_20_23','Designers'' studios',#1891,$,$); +#1895=IFCCLASSIFICATIONREFERENCE($,'SL_25_30','Scientific and laboratory spaces',#1866,$,$); +#1896=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_02','Anechoic chambers',#1895,$,$); +#1897=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_04','Astronomical observatories',#1895,$,$); +#1898=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_05','Autoclave rooms',#1895,$,$); +#1899=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_07','Biological laboratories',#1895,$,$); +#1900=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_10','Bioscience laboratories',#1895,$,$); +#1901=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_13','Chemistry laboratories',#1895,$,$); +#1902=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_14','Clean rooms',#1895,$,$); +#1903=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_15','Clinical biochemistry laboratories',#1895,$,$); +#1904=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_16','Clinical microbiology laboratories',#1895,$,$); +#1905=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_17','Clinical pathology laboratories',#1895,$,$); +#1906=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_19','Containment laboratories',#1895,$,$); +#1907=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_21','Dark rooms',#1895,$,$); +#1908=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_22','Dental laboratories',#1895,$,$); +#1909=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_23','Dissection rooms',#1895,$,$); +#1910=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_26','Earth sciences laboratories',#1895,$,$); +#1911=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_27','Engineering laboratories',#1895,$,$); +#1912=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_28','Experiment control rooms',#1895,$,$); +#1913=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_29','Flow cytometry rooms',#1895,$,$); +#1914=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_30','Food testing laboratories',#1895,$,$); +#1915=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_31','Forensics laboratories',#1895,$,$); +#1916=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_32','Forensic scientific support rooms',#1895,$,$); +#1917=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_33','Geology laboratories',#1895,$,$); +#1918=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_42','Instrument rooms',#1895,$,$); +#1919=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_46','Laboratory cold rooms',#1895,$,$); +#1920=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_47','Laboratory warm rooms',#1895,$,$); +#1921=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_50','Material testing laboratories',#1895,$,$); +#1922=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_66','Physics laboratories',#1895,$,$); +#1923=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_68','Psychology laboratories',#1895,$,$); +#1924=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_70','Radiation shielded rooms',#1895,$,$); +#1925=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_76','Scientific equipment rooms',#1895,$,$); +#1926=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_78','Seismograph rooms',#1895,$,$); +#1927=IFCCLASSIFICATIONREFERENCE($,'SL_25_30_88','Testing rooms',#1895,$,$); +#1928=IFCCLASSIFICATIONREFERENCE($,'SL_25_50','Exhibition spaces',#1866,$,$); +#1929=IFCCLASSIFICATIONREFERENCE($,'SL_25_50_15','Collection exhibition spaces',#1928,$,$); +#1930=IFCCLASSIFICATIONREFERENCE($,'SL_25_50_16','Conservation rooms',#1928,$,$); +#1931=IFCCLASSIFICATIONREFERENCE($,'SL_25_50_21','Diorama rooms',#1928,$,$); +#1932=IFCCLASSIFICATIONREFERENCE($,'SL_25_50_26','External galleries',#1928,$,$); +#1933=IFCCLASSIFICATIONREFERENCE($,'SL_25_50_29','Fauna exhibition spaces',#1928,$,$); +#1934=IFCCLASSIFICATIONREFERENCE($,'SL_25_50_31','Flora exhibition spaces',#1928,$,$); +#1935=IFCCLASSIFICATIONREFERENCE($,'SL_25_50_42','Internal galleries',#1928,$,$); +#1936=IFCCLASSIFICATIONREFERENCE($,'SL_25_50_63','Planetariums',#1928,$,$); +#1937=IFCCLASSIFICATIONREFERENCE($,'SL_25_50_94','Viewing spaces',#1928,$,$); +#1938=IFCCLASSIFICATIONREFERENCE($,'SL_25_70','Information spaces',#1866,$,$); +#1939=IFCCLASSIFICATIONREFERENCE($,'SL_25_70_02','Archives',#1938,$,$); +#1940=IFCCLASSIFICATIONREFERENCE($,'SL_25_70_04','Audio-visual archives',#1938,$,$); +#1941=IFCCLASSIFICATIONREFERENCE($,'SL_25_70_05','Audio-visual study rooms',#1938,$,$); +#1942=IFCCLASSIFICATIONREFERENCE($,'SL_25_70_13','Conference rooms',#1938,$,$); +#1943=IFCCLASSIFICATIONREFERENCE($,'SL_25_70_47','Library rooms',#1938,$,$); +#1944=IFCCLASSIFICATIONREFERENCE($,'SL_25_70_72','Reading rooms',#1938,$,$); +#1945=IFCCLASSIFICATIONREFERENCE($,'SL_25_70_73','Records stores',#1938,$,$); +#1946=IFCCLASSIFICATIONREFERENCE($,'SL_25_90','Worship spaces',#1866,$,$); +#1947=IFCCLASSIFICATIONREFERENCE($,'SL_25_90_30','Faith spaces',#1946,$,$); +#1948=IFCCLASSIFICATIONREFERENCE($,'SL_25_90_65','Prayer rooms',#1946,$,$); +#1949=IFCCLASSIFICATIONREFERENCE($,'SL_25_90_78','Shrines',#1946,$,$); +#1950=IFCCLASSIFICATIONREFERENCE($,'SL_30','Industrial spaces',#1767,$,$); +#1951=IFCCLASSIFICATIONREFERENCE($,'SL_30_10','Mineral extraction spaces',#1950,$,$); +#1952=IFCCLASSIFICATIONREFERENCE($,'SL_30_10_57','Offshore oil and gas drilling spaces',#1951,$,$); +#1953=IFCCLASSIFICATIONREFERENCE($,'SL_30_10_59','Onshore oil and gas drilling spaces',#1951,$,$); +#1954=IFCCLASSIFICATIONREFERENCE($,'SL_30_10_69','Quarrying areas',#1951,$,$); +#1955=IFCCLASSIFICATIONREFERENCE($,'SL_30_10_85','Surface mine workings',#1951,$,$); +#1956=IFCCLASSIFICATIONREFERENCE($,'SL_30_10_91','Underground mine chambers',#1951,$,$); +#1957=IFCCLASSIFICATIONREFERENCE($,'SL_30_10_93','Underground mine shafts',#1951,$,$); +#1958=IFCCLASSIFICATIONREFERENCE($,'SL_30_10_94','Underground mine tunnels',#1951,$,$); +#1959=IFCCLASSIFICATIONREFERENCE($,'SL_30_20','Nuclear and chemical management spaces',#1950,$,$); +#1960=IFCCLASSIFICATIONREFERENCE($,'SL_30_20_70','Radioactive decontamination spaces',#1959,$,$); +#1961=IFCCLASSIFICATIONREFERENCE($,'SL_30_20_75','Radioactive waste package transfer spaces',#1959,$,$); +#1962=IFCCLASSIFICATIONREFERENCE($,'SL_30_30','Mineral processing spaces',#1950,$,$); +#1963=IFCCLASSIFICATIONREFERENCE($,'SL_30_30_33','Gas processing spaces',#1962,$,$); +#1964=IFCCLASSIFICATIONREFERENCE($,'SL_30_30_58','Oil processing spaces',#1962,$,$); +#1965=IFCCLASSIFICATIONREFERENCE($,'SL_30_30_59','Ore processing spaces',#1962,$,$); +#1966=IFCCLASSIFICATIONREFERENCE($,'SL_30_40','Animal and plant products processing spaces',#1950,$,$); +#1967=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_07','Bottling rooms',#1966,$,$); +#1968=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_10','Butter making rooms',#1966,$,$); +#1969=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_18','Cheese making rooms',#1966,$,$); +#1970=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_30','Fish processing rooms',#1966,$,$); +#1971=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_32','Fresh fruit and vegetable packing rooms',#1966,$,$); +#1972=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_44','Juicing rooms',#1966,$,$); +#1973=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_50','Meat processing rooms',#1966,$,$); +#1974=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_54','Milk processing rooms',#1966,$,$); +#1975=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_63','Plant fibre sorting rooms',#1966,$,$); +#1976=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_65','Poultry and game processing rooms',#1966,$,$); +#1977=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_75','Saw mills',#1966,$,$); +#1978=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_80','Silk production rooms',#1966,$,$); +#1979=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_82','Spinning rooms',#1966,$,$); +#1980=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_87','Tanneries',#1966,$,$); +#1981=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_88','Threshing rooms',#1966,$,$); +#1982=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_90','Tobacco drying rooms',#1966,$,$); +#1983=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_96','Weaving rooms',#1966,$,$); +#1984=IFCCLASSIFICATIONREFERENCE($,'SL_30_40_98','Wool sorting rooms',#1966,$,$); +#1985=IFCCLASSIFICATIONREFERENCE($,'SL_30_50','Manufacturing spaces',#1950,$,$); +#1986=IFCCLASSIFICATIONREFERENCE($,'SL_30_50_27','Electronics clean rooms',#1985,$,$); +#1987=IFCCLASSIFICATIONREFERENCE($,'SL_30_50_30','Heavy industrial spaces',#1985,$,$); +#1988=IFCCLASSIFICATIONREFERENCE($,'SL_30_50_40','Kiln rooms',#1985,$,$); +#1989=IFCCLASSIFICATIONREFERENCE($,'SL_30_50_43','Light industrial spaces',#1985,$,$); +#1990=IFCCLASSIFICATIONREFERENCE($,'SL_30_50_50','Manufacturing workshops',#1985,$,$); +#1991=IFCCLASSIFICATIONREFERENCE($,'SL_30_50_60','Packaging lines',#1985,$,$); +#1992=IFCCLASSIFICATIONREFERENCE($,'SL_30_50_61','Paint spray booths',#1985,$,$); +#1993=IFCCLASSIFICATIONREFERENCE($,'SL_30_50_62','Pharmaceuticals clean rooms',#1985,$,$); +#1994=IFCCLASSIFICATIONREFERENCE($,'SL_30_50_64','Printing spaces',#1985,$,$); +#1995=IFCCLASSIFICATIONREFERENCE($,'SL_30_60','Cleaning and maintenance spaces',#1950,$,$); +#1996=IFCCLASSIFICATIONREFERENCE($,'SL_30_60_11','Caretaker rooms',#1995,$,$); +#1997=IFCCLASSIFICATIONREFERENCE($,'SL_30_60_13','Clothes drying and airing rooms',#1995,$,$); +#1998=IFCCLASSIFICATIONREFERENCE($,'SL_30_60_22','Decontamination spaces',#1995,$,$); +#1999=IFCCLASSIFICATIONREFERENCE($,'SL_30_60_24','Dry cleaning spaces',#1995,$,$); +#2000=IFCCLASSIFICATIONREFERENCE($,'SL_30_60_42','Ironing rooms',#1995,$,$); +#2001=IFCCLASSIFICATIONREFERENCE($,'SL_30_60_46','Laundrettes',#1995,$,$); +#2002=IFCCLASSIFICATIONREFERENCE($,'SL_30_60_47','Laundries',#1995,$,$); +#2003=IFCCLASSIFICATIONREFERENCE($,'SL_30_60_50','Maintenance workshops',#1995,$,$); +#2004=IFCCLASSIFICATIONREFERENCE($,'SL_30_60_75','Service laundries',#1995,$,$); +#2005=IFCCLASSIFICATIONREFERENCE($,'SL_30_60_94','Vehicle washes',#1995,$,$); +#2006=IFCCLASSIFICATIONREFERENCE($,'SL_30_60_96','Wash up spaces',#1995,$,$); +#2007=IFCCLASSIFICATIONREFERENCE($,'SL_30_80','Kinetic power generation spaces',#1950,$,$); +#2008=IFCCLASSIFICATIONREFERENCE($,'SL_30_80_96','Water mill houses',#2007,$,$); +#2009=IFCCLASSIFICATIONREFERENCE($,'SL_30_80_97','Wind mill houses',#2007,$,$); +#2010=IFCCLASSIFICATIONREFERENCE($,'SL_30_85','Marine and water maintenance spaces',#1950,$,$); +#2011=IFCCLASSIFICATIONREFERENCE($,'SL_30_85_08','Boat repair spaces',#2010,$,$); +#2012=IFCCLASSIFICATIONREFERENCE($,'SL_30_85_24','Dry dock chambers',#2010,$,$); +#2013=IFCCLASSIFICATIONREFERENCE($,'SL_30_85_30','Floating docks',#2010,$,$); +#2014=IFCCLASSIFICATIONREFERENCE($,'SL_30_85_97','Wet docks',#2010,$,$); +#2015=IFCCLASSIFICATIONREFERENCE($,'SL_30_90','Warehousing and distribution spaces',#1950,$,$); +#2016=IFCCLASSIFICATIONREFERENCE($,'SL_30_90_33','Goods delivery bays',#2015,$,$); +#2017=IFCCLASSIFICATIONREFERENCE($,'SL_30_90_48','Loading docks',#2015,$,$); +#2018=IFCCLASSIFICATIONREFERENCE($,'SL_30_90_80','Sorting and distribution spaces',#2015,$,$); +#2019=IFCCLASSIFICATIONREFERENCE($,'SL_30_90_84','Storage yards',#2015,$,$); +#2020=IFCCLASSIFICATIONREFERENCE($,'SL_30_90_96','Warehouse spaces',#2015,$,$); +#2021=IFCCLASSIFICATIONREFERENCE($,'SL_32','Water and land management spaces',#1767,$,$); +#2022=IFCCLASSIFICATIONREFERENCE($,'SL_32_10','Agricultural and horticultural spaces',#2021,$,$); +#2023=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_03','Arable fields',#2022,$,$); +#2024=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_26','Farm yards',#2022,$,$); +#2025=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_28','Fisheries',#2022,$,$); +#2026=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_30','Fish farm tanks',#2022,$,$); +#2027=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_34','Glasshouse spaces',#2022,$,$); +#2028=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_39','Hothouse spaces',#2022,$,$); +#2029=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_47','Livestock fields',#2022,$,$); +#2030=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_52','Milking parlours',#2022,$,$); +#2031=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_55','Mushroom cultivation spaces',#2022,$,$); +#2032=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_60','Paddocks',#2022,$,$); +#2033=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_65','Poly tunnel spaces',#2022,$,$); +#2034=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_66','Poultry batteries',#2022,$,$); +#2035=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_77','Shearing spaces',#2022,$,$); +#2036=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_78','Sheep dips',#2022,$,$); +#2037=IFCCLASSIFICATIONREFERENCE($,'SL_32_10_94','Vineyard spaces',#2022,$,$); +#2038=IFCCLASSIFICATIONREFERENCE($,'SL_32_35','Ground spaces',#2021,$,$); +#2039=IFCCLASSIFICATIONREFERENCE($,'SL_32_35_22','Decking areas',#2038,$,$); +#2040=IFCCLASSIFICATIONREFERENCE($,'SL_32_35_24','Driveways',#2038,$,$); +#2041=IFCCLASSIFICATIONREFERENCE($,'SL_32_35_30','Flower beds',#2038,$,$); +#2042=IFCCLASSIFICATIONREFERENCE($,'SL_32_35_46','Lawns',#2038,$,$); +#2043=IFCCLASSIFICATIONREFERENCE($,'SL_32_35_60','Patios',#2038,$,$); +#2044=IFCCLASSIFICATIONREFERENCE($,'SL_32_35_94','Vegetable gardens',#2038,$,$); +#2045=IFCCLASSIFICATIONREFERENCE($,'SL_32_40','Land managed spaces',#2021,$,$); +#2046=IFCCLASSIFICATIONREFERENCE($,'SL_32_40_26','Easement access areas',#2045,$,$); +#2047=IFCCLASSIFICATIONREFERENCE($,'SL_32_40_90','Tree protection zones',#2045,$,$); +#2048=IFCCLASSIFICATIONREFERENCE($,'SL_32_50','Marine ways and waterway spaces',#2021,$,$); +#2049=IFCCLASSIFICATIONREFERENCE($,'SL_32_50_06','Beach ramps',#2048,$,$); +#2050=IFCCLASSIFICATIONREFERENCE($,'SL_32_50_18','Deep berths',#2048,$,$); +#2051=IFCCLASSIFICATIONREFERENCE($,'SL_32_50_47','Lifeboat vessel launch spaces',#2048,$,$); +#2052=IFCCLASSIFICATIONREFERENCE($,'SL_32_50_79','Slipways',#2048,$,$); +#2053=IFCCLASSIFICATIONREFERENCE($,'SL_32_60','Marine and waterside spaces',#2021,$,$); +#2054=IFCCLASSIFICATIONREFERENCE($,'SL_32_60_06','Beaches',#2053,$,$); +#2055=IFCCLASSIFICATIONREFERENCE($,'SL_32_60_55','Mudflats',#2053,$,$); +#2056=IFCCLASSIFICATIONREFERENCE($,'SL_32_60_65','Pontoons',#2053,$,$); +#2057=IFCCLASSIFICATIONREFERENCE($,'SL_32_60_76','Sand dunes',#2053,$,$); +#2058=IFCCLASSIFICATIONREFERENCE($,'SL_32_65','Natural spaces',#2021,$,$); +#2059=IFCCLASSIFICATIONREFERENCE($,'SL_32_65_37','Heathlands',#2058,$,$); +#2060=IFCCLASSIFICATIONREFERENCE($,'SL_32_65_50','Marshes and wet grasslands',#2058,$,$); +#2061=IFCCLASSIFICATIONREFERENCE($,'SL_32_65_51','Meadows',#2058,$,$); +#2062=IFCCLASSIFICATIONREFERENCE($,'SL_32_65_53','Moorlands',#2058,$,$); +#2063=IFCCLASSIFICATIONREFERENCE($,'SL_32_65_59','Open grasslands',#2058,$,$); +#2064=IFCCLASSIFICATIONREFERENCE($,'SL_32_65_71','River beds',#2058,$,$); +#2065=IFCCLASSIFICATIONREFERENCE($,'SL_32_65_72','River reaches',#2058,$,$); +#2066=IFCCLASSIFICATIONREFERENCE($,'SL_32_65_73','Rocks and screes',#2058,$,$); +#2067=IFCCLASSIFICATIONREFERENCE($,'SL_32_65_76','Scrub',#2058,$,$); +#2068=IFCCLASSIFICATIONREFERENCE($,'SL_32_65_82','Species rich grassland',#2058,$,$); +#2069=IFCCLASSIFICATIONREFERENCE($,'SL_32_65_95','Washland',#2058,$,$); +#2070=IFCCLASSIFICATIONREFERENCE($,'SL_32_80','Semi-natural spaces',#2021,$,$); +#2071=IFCCLASSIFICATIONREFERENCE($,'SL_32_80_03','Amenity grass areas',#2070,$,$); +#2072=IFCCLASSIFICATIONREFERENCE($,'SL_32_80_08','Brownfield sites',#2070,$,$); +#2073=IFCCLASSIFICATIONREFERENCE($,'SL_32_80_23','Disused mineral extraction sites',#2070,$,$); +#2074=IFCCLASSIFICATIONREFERENCE($,'SL_32_80_50','Mowing strips',#2070,$,$); +#2075=IFCCLASSIFICATIONREFERENCE($,'SL_32_80_89','Transport corridor verges',#2070,$,$); +#2076=IFCCLASSIFICATIONREFERENCE($,'SL_35','Medical, health, welfare and sanitary spaces',#1767,$,$); +#2077=IFCCLASSIFICATIONREFERENCE($,'SL_35_10','Medical spaces',#2076,$,$); +#2078=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_08','Birthing rooms',#2077,$,$); +#2079=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_10','Burns units',#2077,$,$); +#2080=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_15','Consulting rooms',#2077,$,$); +#2081=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_30','First aid posts',#2077,$,$); +#2082=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_31','First aid rooms',#2077,$,$); +#2083=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_36','Hearing test rooms',#2077,$,$); +#2084=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_39','Hydrotherapy pools',#2077,$,$); +#2085=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_42','Intensive care units',#2077,$,$); +#2086=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_43','Isolation units',#2077,$,$); +#2087=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_51','Medical scanning and x-ray rooms',#2077,$,$); +#2088=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_53','Medical treatment spaces',#2077,$,$); +#2089=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_58','Occupational therapy rooms',#2077,$,$); +#2090=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_59','Operating theatres',#2077,$,$); +#2091=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_64','Pharmaceutical dispensaries',#2077,$,$); +#2092=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_65','Phototherapy spaces',#2077,$,$); +#2093=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_66','Physiotherapy rooms',#2077,$,$); +#2094=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_70','Radiography rooms',#2077,$,$); +#2095=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_71','Radiotherapy rooms',#2077,$,$); +#2096=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_73','Recovery rooms',#2077,$,$); +#2097=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_74','Rehabilitation rooms',#2077,$,$); +#2098=IFCCLASSIFICATIONREFERENCE($,'SL_35_10_96','Wards',#2077,$,$); +#2099=IFCCLASSIFICATIONREFERENCE($,'SL_35_50','Welfare spaces',#2076,$,$); +#2100=IFCCLASSIFICATIONREFERENCE($,'SL_35_50_17','Cr\X2\00E8\X0\ches and nurseries',#2099,$,$); +#2101=IFCCLASSIFICATIONREFERENCE($,'SL_35_50_21','Day care spaces',#2099,$,$); +#2102=IFCCLASSIFICATIONREFERENCE($,'SL_35_50_60','Parent and baby rooms',#2099,$,$); +#2103=IFCCLASSIFICATIONREFERENCE($,'SL_35_50_75','Sauna rooms',#2099,$,$); +#2104=IFCCLASSIFICATIONREFERENCE($,'SL_35_50_90','Treatment rooms',#2099,$,$); +#2105=IFCCLASSIFICATIONREFERENCE($,'SL_35_60','Food management spaces',#2076,$,$); +#2106=IFCCLASSIFICATIONREFERENCE($,'SL_35_60_14','Commercial kitchens',#2105,$,$); +#2107=IFCCLASSIFICATIONREFERENCE($,'SL_35_60_16','Cooking spaces',#2105,$,$); +#2108=IFCCLASSIFICATIONREFERENCE($,'SL_35_60_30','Food preparation areas',#2105,$,$); +#2109=IFCCLASSIFICATIONREFERENCE($,'SL_35_60_56','Non-domestic kitchens',#2105,$,$); +#2110=IFCCLASSIFICATIONREFERENCE($,'SL_35_70','Funerary spaces',#2076,$,$); +#2111=IFCCLASSIFICATIONREFERENCE($,'SL_35_70_12','Cemetery plots',#2110,$,$); +#2112=IFCCLASSIFICATIONREFERENCE($,'SL_35_70_15','Columbariums',#2110,$,$); +#2113=IFCCLASSIFICATIONREFERENCE($,'SL_35_70_18','Crematorium oven rooms',#2110,$,$); +#2114=IFCCLASSIFICATIONREFERENCE($,'SL_35_70_32','Funeral vaults',#2110,$,$); +#2115=IFCCLASSIFICATIONREFERENCE($,'SL_35_70_50','Mausoleums',#2110,$,$); +#2116=IFCCLASSIFICATIONREFERENCE($,'SL_35_70_90','Tombs',#2110,$,$); +#2117=IFCCLASSIFICATIONREFERENCE($,'SL_35_80','Sanitary spaces',#2076,$,$); +#2118=IFCCLASSIFICATIONREFERENCE($,'SL_35_80_06','Baby changing rooms',#2117,$,$); +#2119=IFCCLASSIFICATIONREFERENCE($,'SL_35_80_08','Bathrooms',#2117,$,$); +#2120=IFCCLASSIFICATIONREFERENCE($,'SL_35_80_59','Open shower areas',#2117,$,$); +#2121=IFCCLASSIFICATIONREFERENCE($,'SL_35_80_68','Public toilets',#2117,$,$); +#2122=IFCCLASSIFICATIONREFERENCE($,'SL_35_80_80','Showers',#2117,$,$); +#2123=IFCCLASSIFICATIONREFERENCE($,'SL_35_80_89','Toilets',#2117,$,$); +#2124=IFCCLASSIFICATIONREFERENCE($,'SL_35_85','Animal spaces',#2076,$,$); +#2125=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_00','Animal arks',#2124,$,$); +#2126=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_01','Animal cages',#2124,$,$); +#2127=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_03','Animal enclosures',#2124,$,$); +#2128=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_04','Animal exercise arenas',#2124,$,$); +#2129=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_05','Aviaries',#2124,$,$); +#2130=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_12','Cattle byres',#2124,$,$); +#2131=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_39','Fish tanks',#2124,$,$); +#2132=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_45','Kennels',#2124,$,$); +#2133=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_47','Loose boxes',#2124,$,$); +#2134=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_62','Pens',#2124,$,$); +#2135=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_83','Stables',#2124,$,$); +#2136=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_84','Stable yards',#2124,$,$); +#2137=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_85','Stalls',#2124,$,$); +#2138=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_86','Sties',#2124,$,$); +#2139=IFCCLASSIFICATIONREFERENCE($,'SL_35_85_88','Tack rooms',#2124,$,$); +#2140=IFCCLASSIFICATIONREFERENCE($,'SL_35_90','Animal medical, health, welfare and funerary spaces',#2076,$,$); +#2141=IFCCLASSIFICATIONREFERENCE($,'SL_35_90_10','Animal burial plots',#2140,$,$); +#2142=IFCCLASSIFICATIONREFERENCE($,'SL_35_90_15','Animal clinics',#2140,$,$); +#2143=IFCCLASSIFICATIONREFERENCE($,'SL_35_90_22','Animal dispensaries',#2140,$,$); +#2144=IFCCLASSIFICATIONREFERENCE($,'SL_35_90_32','Animal funerary spaces',#2140,$,$); +#2145=IFCCLASSIFICATIONREFERENCE($,'SL_35_90_34','Animal grooming facilities',#2140,$,$); +#2146=IFCCLASSIFICATIONREFERENCE($,'SL_35_90_37','Animal hydrotherapy pools',#2140,$,$); +#2147=IFCCLASSIFICATIONREFERENCE($,'SL_35_90_59','Animal operating theatres',#2140,$,$); +#2148=IFCCLASSIFICATIONREFERENCE($,'SL_35_90_72','Animal wards',#2140,$,$); +#2149=IFCCLASSIFICATIONREFERENCE($,'SL_40','Recreational spaces',#1767,$,$); +#2150=IFCCLASSIFICATIONREFERENCE($,'SL_40_05','Amusement spaces',#2149,$,$); +#2151=IFCCLASSIFICATIONREFERENCE($,'SL_40_05_03','Amusement arcades',#2150,$,$); +#2152=IFCCLASSIFICATIONREFERENCE($,'SL_40_05_13','Casino floors',#2150,$,$); +#2153=IFCCLASSIFICATIONREFERENCE($,'SL_40_05_42','Indoor fairground spaces',#2150,$,$); +#2154=IFCCLASSIFICATIONREFERENCE($,'SL_40_05_43','Indoor play spaces',#2150,$,$); +#2155=IFCCLASSIFICATIONREFERENCE($,'SL_40_05_58','Observation decks',#2150,$,$); +#2156=IFCCLASSIFICATIONREFERENCE($,'SL_40_05_59','Outdoor activity areas',#2150,$,$); +#2157=IFCCLASSIFICATIONREFERENCE($,'SL_40_05_60','Outdoor fairground spaces',#2150,$,$); +#2158=IFCCLASSIFICATIONREFERENCE($,'SL_40_05_61','Outdoor playgrounds',#2150,$,$); +#2159=IFCCLASSIFICATIONREFERENCE($,'SL_40_05_68','Public parks and gardens',#2150,$,$); +#2160=IFCCLASSIFICATIONREFERENCE($,'SL_40_20','Dining spaces',#2149,$,$); +#2161=IFCCLASSIFICATIONREFERENCE($,'SL_40_20_06','Bars',#2160,$,$); +#2162=IFCCLASSIFICATIONREFERENCE($,'SL_40_20_09','Beverage stations',#2160,$,$); +#2163=IFCCLASSIFICATIONREFERENCE($,'SL_40_20_27','Enclosed dining areas',#2160,$,$); +#2164=IFCCLASSIFICATIONREFERENCE($,'SL_40_20_28','Food courts',#2160,$,$); +#2165=IFCCLASSIFICATIONREFERENCE($,'SL_40_20_59','Outdoor dining areas',#2160,$,$); +#2166=IFCCLASSIFICATIONREFERENCE($,'SL_40_60','Performing arts spaces',#2149,$,$); +#2167=IFCCLASSIFICATIONREFERENCE($,'SL_40_60_05','Auditoriums',#2166,$,$); +#2168=IFCCLASSIFICATIONREFERENCE($,'SL_40_60_06','Bandstands',#2166,$,$); +#2169=IFCCLASSIFICATIONREFERENCE($,'SL_40_60_11','Cat walks',#2166,$,$); +#2170=IFCCLASSIFICATIONREFERENCE($,'SL_40_60_13','Circus rings',#2166,$,$); +#2171=IFCCLASSIFICATIONREFERENCE($,'SL_40_60_21','Dance floors',#2166,$,$); +#2172=IFCCLASSIFICATIONREFERENCE($,'SL_40_60_31','Fixed stages',#2166,$,$); +#2173=IFCCLASSIFICATIONREFERENCE($,'SL_40_60_40','Indoor theatre spaces',#2166,$,$); +#2174=IFCCLASSIFICATIONREFERENCE($,'SL_40_60_52','Mobile stages',#2166,$,$); +#2175=IFCCLASSIFICATIONREFERENCE($,'SL_40_60_58','Orchestra pits',#2166,$,$); +#2176=IFCCLASSIFICATIONREFERENCE($,'SL_40_60_59','Outdoor theatre spaces',#2166,$,$); +#2177=IFCCLASSIFICATIONREFERENCE($,'SL_40_60_78','Sound recording studios',#2166,$,$); +#2178=IFCCLASSIFICATIONREFERENCE($,'SL_40_60_80','Sound shells',#2166,$,$); +#2179=IFCCLASSIFICATIONREFERENCE($,'SL_40_60_81','Sound stages',#2166,$,$); +#2180=IFCCLASSIFICATIONREFERENCE($,'SL_40_65','Performing arts ancillary spaces',#2149,$,$); +#2181=IFCCLASSIFICATIONREFERENCE($,'SL_40_65_04','Audience lobbies',#2180,$,$); +#2182=IFCCLASSIFICATIONREFERENCE($,'SL_40_65_24','Dressing rooms',#2180,$,$); +#2183=IFCCLASSIFICATIONREFERENCE($,'SL_40_65_35','Green rooms',#2180,$,$); +#2184=IFCCLASSIFICATIONREFERENCE($,'SL_40_65_47','Lighting control booths',#2180,$,$); +#2185=IFCCLASSIFICATIONREFERENCE($,'SL_40_65_66','Projection booths',#2180,$,$); +#2186=IFCCLASSIFICATIONREFERENCE($,'SL_40_65_70','Recording control booths',#2180,$,$); +#2187=IFCCLASSIFICATIONREFERENCE($,'SL_40_65_72','Rehearsal rooms',#2180,$,$); +#2188=IFCCLASSIFICATIONREFERENCE($,'SL_40_65_76','Scenery control booths',#2180,$,$); +#2189=IFCCLASSIFICATIONREFERENCE($,'SL_40_65_79','Sound control booths',#2180,$,$); +#2190=IFCCLASSIFICATIONREFERENCE($,'SL_40_65_80','Sound locks',#2180,$,$); +#2191=IFCCLASSIFICATIONREFERENCE($,'SL_40_65_85','Stage wings',#2180,$,$); +#2192=IFCCLASSIFICATIONREFERENCE($,'SL_42','Sport and activity spaces',#1767,$,$); +#2193=IFCCLASSIFICATIONREFERENCE($,'SL_42_15','Courts, pitches and field sports spaces',#2192,$,$); +#2194=IFCCLASSIFICATIONREFERENCE($,'SL_42_15_37','High jump areas',#2193,$,$); +#2195=IFCCLASSIFICATIONREFERENCE($,'SL_42_15_42','Indoor sports courts and pitches',#2193,$,$); +#2196=IFCCLASSIFICATIONREFERENCE($,'SL_42_15_44','Javelin throwing areas',#2193,$,$); +#2197=IFCCLASSIFICATIONREFERENCE($,'SL_42_15_47','Long jump tracks and pits',#2193,$,$); +#2198=IFCCLASSIFICATIONREFERENCE($,'SL_42_15_59','Outdoor sports courts',#2193,$,$); +#2199=IFCCLASSIFICATIONREFERENCE($,'SL_42_15_60','Outdoor sports pitches and fields',#2193,$,$); +#2200=IFCCLASSIFICATIONREFERENCE($,'SL_42_15_65','Pole vaulting areas',#2193,$,$); +#2201=IFCCLASSIFICATIONREFERENCE($,'SL_42_15_74','Running tracks',#2193,$,$); +#2202=IFCCLASSIFICATIONREFERENCE($,'SL_42_15_78','Shot put and hammer throwing areas',#2193,$,$); +#2203=IFCCLASSIFICATIONREFERENCE($,'SL_42_40','Indoor activity spaces',#2192,$,$); +#2204=IFCCLASSIFICATIONREFERENCE($,'SL_42_40_09','Bouldering spaces',#2203,$,$); +#2205=IFCCLASSIFICATIONREFERENCE($,'SL_42_40_14','Climbing wall areas',#2203,$,$); +#2206=IFCCLASSIFICATIONREFERENCE($,'SL_42_40_20','Cycle tracks',#2203,$,$); +#2207=IFCCLASSIFICATIONREFERENCE($,'SL_42_40_23','Dojo',#2203,$,$); +#2208=IFCCLASSIFICATIONREFERENCE($,'SL_42_40_30','Fitness rooms',#2203,$,$); +#2209=IFCCLASSIFICATIONREFERENCE($,'SL_42_40_35','Gymnasiums',#2203,$,$); +#2210=IFCCLASSIFICATIONREFERENCE($,'SL_42_40_37','Gymnastics areas',#2203,$,$); +#2211=IFCCLASSIFICATIONREFERENCE($,'SL_42_40_79','Snooker, billiards and pool halls',#2203,$,$); +#2212=IFCCLASSIFICATIONREFERENCE($,'SL_42_40_90','Ten pin bowling alleys',#2203,$,$); +#2213=IFCCLASSIFICATIONREFERENCE($,'SL_42_55','Outdoor activity spaces',#2192,$,$); +#2214=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_01','Archery ranges',#2213,$,$); +#2215=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_07','BMX cycling tracks',#2213,$,$); +#2216=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_08','Bowling greens',#2213,$,$); +#2217=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_17','Cross-country cycling courses',#2213,$,$); +#2218=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_18','Cross country equestrian courses',#2213,$,$); +#2219=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_19','Cross-country rallying courses',#2213,$,$); +#2220=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_20','Cross-country running courses',#2213,$,$); +#2221=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_23','Dog racing tracks',#2213,$,$); +#2222=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_26','Equestrian arenas',#2213,$,$); +#2223=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_35','Golf fairways',#2213,$,$); +#2224=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_39','Horse racing courses',#2213,$,$); +#2225=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_53','Motor racing tracks',#2213,$,$); +#2226=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_60','Parkour courses',#2213,$,$); +#2227=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_65','Putting greens',#2213,$,$); +#2228=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_72','Road running courses',#2213,$,$); +#2229=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_76','Skateboarding parks',#2213,$,$); +#2230=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_82','Speedway tracks',#2213,$,$); +#2231=IFCCLASSIFICATIONREFERENCE($,'SL_42_55_96','Walking trails',#2213,$,$); +#2232=IFCCLASSIFICATIONREFERENCE($,'SL_42_80','Sports and activity ancillary spaces',#2192,$,$); +#2233=IFCCLASSIFICATIONREFERENCE($,'SL_42_80_65','Press boxes',#2232,$,$); +#2234=IFCCLASSIFICATIONREFERENCE($,'SL_42_80_88','Technical areas and dugouts',#2232,$,$); +#2235=IFCCLASSIFICATIONREFERENCE($,'SL_42_85','Swimming spaces',#2192,$,$); +#2236=IFCCLASSIFICATIONREFERENCE($,'SL_42_85_23','Diving pools',#2235,$,$); +#2237=IFCCLASSIFICATIONREFERENCE($,'SL_42_85_64','Plunge pools',#2235,$,$); +#2238=IFCCLASSIFICATIONREFERENCE($,'SL_42_85_80','Spa pools',#2235,$,$); +#2239=IFCCLASSIFICATIONREFERENCE($,'SL_42_85_82','Splash pools',#2235,$,$); +#2240=IFCCLASSIFICATIONREFERENCE($,'SL_42_85_83','Swimming pools',#2235,$,$); +#2241=IFCCLASSIFICATIONREFERENCE($,'SL_42_85_94','Water flumes, slides and tubes',#2235,$,$); +#2242=IFCCLASSIFICATIONREFERENCE($,'SL_42_85_97','Wave pools',#2235,$,$); +#2243=IFCCLASSIFICATIONREFERENCE($,'SL_42_85_98','Whirlpools',#2235,$,$); +#2244=IFCCLASSIFICATIONREFERENCE($,'SL_42_90','Water activity spaces',#2192,$,$); +#2245=IFCCLASSIFICATIONREFERENCE($,'SL_42_90_11','Canoe slalom courses',#2244,$,$); +#2246=IFCCLASSIFICATIONREFERENCE($,'SL_42_90_12','Canoe sprint courses',#2244,$,$); +#2247=IFCCLASSIFICATIONREFERENCE($,'SL_42_90_50','Motor boat courses',#2244,$,$); +#2248=IFCCLASSIFICATIONREFERENCE($,'SL_42_90_73','Rowing courses',#2244,$,$); +#2249=IFCCLASSIFICATIONREFERENCE($,'SL_42_90_75','Sailing courses',#2244,$,$); +#2250=IFCCLASSIFICATIONREFERENCE($,'SL_42_90_97','Water skiing courses',#2244,$,$); +#2251=IFCCLASSIFICATIONREFERENCE($,'SL_42_90_98','White water canoe courses',#2244,$,$); +#2252=IFCCLASSIFICATIONREFERENCE($,'SL_42_95','Winter sports spaces',#2192,$,$); +#2253=IFCCLASSIFICATIONREFERENCE($,'SL_42_95_02','Alpine skiing courses',#2252,$,$); +#2254=IFCCLASSIFICATIONREFERENCE($,'SL_42_95_04','Artificial ski slopes',#2252,$,$); +#2255=IFCCLASSIFICATIONREFERENCE($,'SL_42_95_08','Bobsleigh courses',#2252,$,$); +#2256=IFCCLASSIFICATIONREFERENCE($,'SL_42_95_19','Cross-country skiing courses',#2252,$,$); +#2257=IFCCLASSIFICATIONREFERENCE($,'SL_42_95_20','Curling rinks',#2252,$,$); +#2258=IFCCLASSIFICATIONREFERENCE($,'SL_42_95_32','Freestyle skiing courses',#2252,$,$); +#2259=IFCCLASSIFICATIONREFERENCE($,'SL_42_95_40','Ice skating rinks',#2252,$,$); +#2260=IFCCLASSIFICATIONREFERENCE($,'SL_42_95_76','Short track speed skating tracks',#2252,$,$); +#2261=IFCCLASSIFICATIONREFERENCE($,'SL_42_95_79','Ski jumps',#2252,$,$); +#2262=IFCCLASSIFICATIONREFERENCE($,'SL_42_95_80','Snowboarding courses',#2252,$,$); +#2263=IFCCLASSIFICATIONREFERENCE($,'SL_42_95_83','Speed skating courses',#2252,$,$); +#2264=IFCCLASSIFICATIONREFERENCE($,'SL_45','Residential spaces',#1767,$,$); +#2265=IFCCLASSIFICATIONREFERENCE($,'SL_45_10','Living spaces',#2264,$,$); +#2266=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_06','Balconies',#2265,$,$); +#2267=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_08','Bedroom-studies',#2265,$,$); +#2268=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_09','Bedrooms',#2265,$,$); +#2269=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_12','Caravan pitches',#2265,$,$); +#2270=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_14','Communal living rooms',#2265,$,$); +#2271=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_16','Concierge offices',#2265,$,$); +#2272=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_18','Conservatories',#2265,$,$); +#2273=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_22','Domestic dining rooms',#2265,$,$); +#2274=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_23','Domestic kitchens',#2265,$,$); +#2275=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_24','Dormitories',#2265,$,$); +#2276=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_37','Hotel rooms',#2265,$,$); +#2277=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_44','Kitchen-dining rooms',#2265,$,$); +#2278=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_49','Living rooms',#2265,$,$); +#2279=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_57','Nursing home bedrooms',#2265,$,$); +#2280=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_60','Panic rooms',#2265,$,$); +#2281=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_85','Studies',#2265,$,$); +#2282=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_88','Tent pitches',#2265,$,$); +#2283=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_93','Utility rooms',#2265,$,$); +#2284=IFCCLASSIFICATIONREFERENCE($,'SL_45_10_94','Verandas',#2265,$,$); +#2285=IFCCLASSIFICATIONREFERENCE($,'SL_50','Waste disposal spaces and locations',#1767,$,$); +#2286=IFCCLASSIFICATIONREFERENCE($,'SL_50_10','Gas waste collection spaces',#2285,$,$); +#2287=IFCCLASSIFICATIONREFERENCE($,'SL_50_20','Wet waste collection spaces',#2285,$,$); +#2288=IFCCLASSIFICATIONREFERENCE($,'SL_50_30','Drainage collection spaces',#2285,$,$); +#2289=IFCCLASSIFICATIONREFERENCE($,'SL_50_35','Drainage collection locations',#2285,$,$); +#2290=IFCCLASSIFICATIONREFERENCE($,'SL_50_35_36','Grip inlets',#2289,$,$); +#2291=IFCCLASSIFICATIONREFERENCE($,'SL_50_35_41','Inlet discharge',#2289,$,$); +#2292=IFCCLASSIFICATIONREFERENCE($,'SL_50_35_59','Outlet discharge',#2289,$,$); +#2293=IFCCLASSIFICATIONREFERENCE($,'SL_50_40','Dry waste collection spaces',#2285,$,$); +#2294=IFCCLASSIFICATIONREFERENCE($,'SL_50_40_72','Refuse storage space',#2293,$,$); +#2295=IFCCLASSIFICATIONREFERENCE($,'SL_50_50','Gas waste treatment and disposal spaces',#2285,$,$); +#2296=IFCCLASSIFICATIONREFERENCE($,'SL_50_50_92','Waste gas treatment spaces',#2295,$,$); +#2297=IFCCLASSIFICATIONREFERENCE($,'SL_50_60','Wet waste treatment and disposal spaces',#2285,$,$); +#2298=IFCCLASSIFICATIONREFERENCE($,'SL_50_60_28','Evaporation ponds',#2297,$,$); +#2299=IFCCLASSIFICATIONREFERENCE($,'SL_50_60_94','Waste liquids treatment spaces',#2297,$,$); +#2300=IFCCLASSIFICATIONREFERENCE($,'SL_50_70','Drainage treatment and disposal spaces',#2285,$,$); +#2301=IFCCLASSIFICATIONREFERENCE($,'SL_50_75','Wastewater treatment and disposal spaces',#2285,$,$); +#2302=IFCCLASSIFICATIONREFERENCE($,'SL_50_75_40','Wastewater treatment spaces',#2301,$,$); +#2303=IFCCLASSIFICATIONREFERENCE($,'SL_50_75_70','Wastewater disposal spaces',#2301,$,$); +#2304=IFCCLASSIFICATIONREFERENCE($,'SL_50_80','Dry waste treatment and disposal spaces',#2285,$,$); +#2305=IFCCLASSIFICATIONREFERENCE($,'SL_50_80_40','Dry waste treatment spaces',#2304,$,$); +#2306=IFCCLASSIFICATIONREFERENCE($,'SL_50_80_70','Dry waste disposal spaces',#2304,$,$); +#2307=IFCCLASSIFICATIONREFERENCE($,'SL_55','Piped supply spaces',#1767,$,$); +#2308=IFCCLASSIFICATIONREFERENCE($,'SL_55_05','Gas extraction and treatment spaces',#2307,$,$); +#2309=IFCCLASSIFICATIONREFERENCE($,'SL_55_05_30','Gas extraction spaces',#2308,$,$); +#2310=IFCCLASSIFICATIONREFERENCE($,'SL_55_05_70','Gas treatment spaces',#2308,$,$); +#2311=IFCCLASSIFICATIONREFERENCE($,'SL_55_10','Liquid fuel extraction and treatment spaces',#2307,$,$); +#2312=IFCCLASSIFICATIONREFERENCE($,'SL_55_10_10','Oil extraction spaces',#2311,$,$); +#2313=IFCCLASSIFICATIONREFERENCE($,'SL_55_10_50','Oil treatment spaces',#2311,$,$); +#2314=IFCCLASSIFICATIONREFERENCE($,'SL_55_15','Water extraction and treatment spaces',#2307,$,$); +#2315=IFCCLASSIFICATIONREFERENCE($,'SL_55_15_10','Water extraction spaces',#2314,$,$); +#2316=IFCCLASSIFICATIONREFERENCE($,'SL_55_15_50','Water treatment spaces',#2314,$,$); +#2317=IFCCLASSIFICATIONREFERENCE($,'SL_55_20','Gas supply spaces',#2307,$,$); +#2318=IFCCLASSIFICATIONREFERENCE($,'SL_55_30','Fire extinguishing supply spaces',#2307,$,$); +#2319=IFCCLASSIFICATIONREFERENCE($,'SL_55_40','Steam supply spaces',#2307,$,$); +#2320=IFCCLASSIFICATIONREFERENCE($,'SL_55_50','Liquid fuel supply spaces',#2307,$,$); +#2321=IFCCLASSIFICATIONREFERENCE($,'SL_55_60','Process liquid supply spaces',#2307,$,$); +#2322=IFCCLASSIFICATIONREFERENCE($,'SL_55_65','Ventilation and air conditioning spaces',#2307,$,$); +#2323=IFCCLASSIFICATIONREFERENCE($,'SL_55_70','Water supply spaces',#2307,$,$); +#2324=IFCCLASSIFICATIONREFERENCE($,'SL_55_70_65','Private supply pipes',#2323,$,$); +#2325=IFCCLASSIFICATIONREFERENCE($,'SL_55_90','Piped solids supply spaces',#2307,$,$); +#2326=IFCCLASSIFICATIONREFERENCE($,'SL_60','Heating, cooling and refrigeration spaces',#1767,$,$); +#2327=IFCCLASSIFICATIONREFERENCE($,'SL_60_30','Rail and paving heating spaces',#2326,$,$); +#2328=IFCCLASSIFICATIONREFERENCE($,'SL_60_40','Space heating and cooling spaces',#2326,$,$); +#2329=IFCCLASSIFICATIONREFERENCE($,'SL_60_60','Refrigeration spaces',#2326,$,$); +#2330=IFCCLASSIFICATIONREFERENCE($,'SL_60_80','Drying spaces',#2326,$,$); +#2331=IFCCLASSIFICATIONREFERENCE($,'SL_60_80_25','Drying rooms',#2330,$,$); +#2332=IFCCLASSIFICATIONREFERENCE($,'SL_70','Electrical power generation and lighting spaces',#1767,$,$); +#2333=IFCCLASSIFICATIONREFERENCE($,'SL_70_10','Electrical power generation spaces',#2332,$,$); +#2334=IFCCLASSIFICATIONREFERENCE($,'SL_70_10_91','Turbine rooms',#2333,$,$); +#2335=IFCCLASSIFICATIONREFERENCE($,'SL_70_30','Electricity distribution and transmission spaces',#2332,$,$); +#2336=IFCCLASSIFICATIONREFERENCE($,'SL_70_30_35','High-voltage electricity substation chambers',#2335,$,$); +#2337=IFCCLASSIFICATIONREFERENCE($,'SL_70_30_45','Low-voltage electricity substation chambers',#2335,$,$); +#2338=IFCCLASSIFICATIONREFERENCE($,'SL_75','Communications, security, safety and protection spaces',#1767,$,$); +#2339=IFCCLASSIFICATIONREFERENCE($,'SL_75_10','Communications spaces',#2338,$,$); +#2340=IFCCLASSIFICATIONREFERENCE($,'SL_75_10_21','Communications equipment rooms',#2339,$,$); +#2341=IFCCLASSIFICATIONREFERENCE($,'SL_75_10_23','Digital data transmission networks',#2339,$,$); +#2342=IFCCLASSIFICATIONREFERENCE($,'SL_75_10_70','Radio broadcast control booths',#2339,$,$); +#2343=IFCCLASSIFICATIONREFERENCE($,'SL_75_10_73','Radio studios',#2339,$,$); +#2344=IFCCLASSIFICATIONREFERENCE($,'SL_75_10_88','Telecommunications control spaces',#2339,$,$); +#2345=IFCCLASSIFICATIONREFERENCE($,'SL_75_10_89','Telephone boxes and booths',#2339,$,$); +#2346=IFCCLASSIFICATIONREFERENCE($,'SL_75_10_90','Telephone exchange spaces',#2339,$,$); +#2347=IFCCLASSIFICATIONREFERENCE($,'SL_75_10_91','Television broadcast control booths',#2339,$,$); +#2348=IFCCLASSIFICATIONREFERENCE($,'SL_75_10_93','Television studios',#2339,$,$); +#2349=IFCCLASSIFICATIONREFERENCE($,'SL_75_30','Signalling spaces',#2338,$,$); +#2350=IFCCLASSIFICATIONREFERENCE($,'SL_75_30_80','Signal boxes',#2349,$,$); +#2351=IFCCLASSIFICATIONREFERENCE($,'SL_75_40','Electronic security spaces',#2338,$,$); +#2352=IFCCLASSIFICATIONREFERENCE($,'SL_75_40_28','Electronic security control rooms',#2351,$,$); +#2353=IFCCLASSIFICATIONREFERENCE($,'SL_75_50','Safety and protection spaces',#2338,$,$); +#2354=IFCCLASSIFICATIONREFERENCE($,'SL_75_60','Environmental safety',#2338,$,$); +#2355=IFCCLASSIFICATIONREFERENCE($,'SL_75_70','Control and management spaces',#2338,$,$); +#2356=IFCCLASSIFICATIONREFERENCE($,'SL_75_80','Protection spaces',#2338,$,$); +#2357=IFCCLASSIFICATIONREFERENCE($,'SL_80','Transport spaces',#1767,$,$); +#2358=IFCCLASSIFICATIONREFERENCE($,'SL_80_05','Aerospace ground spaces',#2357,$,$); +#2359=IFCCLASSIFICATIONREFERENCE($,'SL_80_05_02','Aeroplane landing strips',#2358,$,$); +#2360=IFCCLASSIFICATIONREFERENCE($,'SL_80_05_03','Aeroplane runways',#2358,$,$); +#2361=IFCCLASSIFICATIONREFERENCE($,'SL_80_05_04','Aircraft fuelling spaces',#2358,$,$); +#2362=IFCCLASSIFICATIONREFERENCE($,'SL_80_05_05','Aircraft manoeuvring areas',#2358,$,$); +#2363=IFCCLASSIFICATIONREFERENCE($,'SL_80_05_06','Aircraft standing areas',#2358,$,$); +#2364=IFCCLASSIFICATIONREFERENCE($,'SL_80_05_07','Aircraft storage spaces',#2358,$,$); +#2365=IFCCLASSIFICATIONREFERENCE($,'SL_80_05_33','Gliding runways',#2358,$,$); +#2366=IFCCLASSIFICATIONREFERENCE($,'SL_80_05_37','Hang gliding launch spaces',#2358,$,$); +#2367=IFCCLASSIFICATIONREFERENCE($,'SL_80_05_38','Helipads',#2358,$,$); +#2368=IFCCLASSIFICATIONREFERENCE($,'SL_80_05_82','Spacecraft landing strips',#2358,$,$); +#2369=IFCCLASSIFICATIONREFERENCE($,'SL_80_05_84','Spacecraft launch pads',#2358,$,$); +#2370=IFCCLASSIFICATIONREFERENCE($,'SL_80_10','Loading and embarkation spaces',#2357,$,$); +#2371=IFCCLASSIFICATIONREFERENCE($,'SL_80_10_06','Baggage claim areas',#2370,$,$); +#2372=IFCCLASSIFICATIONREFERENCE($,'SL_80_10_07','Baggage handling areas',#2370,$,$); +#2373=IFCCLASSIFICATIONREFERENCE($,'SL_80_10_09','Boarding areas',#2370,$,$); +#2374=IFCCLASSIFICATIONREFERENCE($,'SL_80_10_10','Bus stops',#2370,$,$); +#2375=IFCCLASSIFICATIONREFERENCE($,'SL_80_10_12','Cargo handling areas',#2370,$,$); +#2376=IFCCLASSIFICATIONREFERENCE($,'SL_80_10_13','Cargo loading areas',#2370,$,$); +#2377=IFCCLASSIFICATIONREFERENCE($,'SL_80_10_16','Concourses',#2370,$,$); +#2378=IFCCLASSIFICATIONREFERENCE($,'SL_80_10_20','Customs control areas',#2370,$,$); +#2379=IFCCLASSIFICATIONREFERENCE($,'SL_80_10_22','Departure lounges',#2370,$,$); +#2380=IFCCLASSIFICATIONREFERENCE($,'SL_80_10_55','Passenger gates',#2370,$,$); +#2381=IFCCLASSIFICATIONREFERENCE($,'SL_80_10_60','Passport control offices',#2370,$,$); +#2382=IFCCLASSIFICATIONREFERENCE($,'SL_80_10_77','Security screening areas',#2370,$,$); +#2383=IFCCLASSIFICATIONREFERENCE($,'SL_80_10_80','Ship gangways',#2370,$,$); +#2384=IFCCLASSIFICATIONREFERENCE($,'SL_80_15','Aerospace maintenance spaces',#2357,$,$); +#2385=IFCCLASSIFICATIONREFERENCE($,'SL_80_15_01','Aircraft cleaning spaces',#2384,$,$); +#2386=IFCCLASSIFICATIONREFERENCE($,'SL_80_15_04','Aircraft repair spaces',#2384,$,$); +#2387=IFCCLASSIFICATIONREFERENCE($,'SL_80_15_06','Airport control spaces',#2384,$,$); +#2388=IFCCLASSIFICATIONREFERENCE($,'SL_80_15_79','Spacecraft cleaning spaces',#2384,$,$); +#2389=IFCCLASSIFICATIONREFERENCE($,'SL_80_15_81','Spacecraft preparation spaces',#2384,$,$); +#2390=IFCCLASSIFICATIONREFERENCE($,'SL_80_15_82','Spacecraft repair spaces',#2384,$,$); +#2391=IFCCLASSIFICATIONREFERENCE($,'SL_80_20','Cableways',#2357,$,$); +#2392=IFCCLASSIFICATIONREFERENCE($,'SL_80_20_13','Cableways',#2391,$,$); +#2393=IFCCLASSIFICATIONREFERENCE($,'SL_80_30','Cable transport storage and maintenance spaces',#2357,$,$); +#2394=IFCCLASSIFICATIONREFERENCE($,'SL_80_30_34','Gondola repair and cleaning spaces',#2393,$,$); +#2395=IFCCLASSIFICATIONREFERENCE($,'SL_80_30_35','Gondola storage spaces',#2393,$,$); +#2396=IFCCLASSIFICATIONREFERENCE($,'SL_80_35','Road spaces',#2357,$,$); +#2397=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_04','Arrestor beds',#2396,$,$); +#2398=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_08','Bus manoeuvring areas',#2396,$,$); +#2399=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_11','Car manoeuvring areas',#2396,$,$); +#2400=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_13','Carriageways',#2396,$,$); +#2401=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_16','Central reservations',#2396,$,$); +#2402=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_18','Crossover spaces',#2396,$,$); +#2403=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_19','Cycle crossings',#2396,$,$); +#2404=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_20','Cycle lanes',#2396,$,$); +#2405=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_22','Diversion routes',#2396,$,$); +#2406=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_36','Hard shoulders',#2396,$,$); +#2407=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_37','Hard standings',#2396,$,$); +#2408=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_39','Highway pull-offs',#2396,$,$); +#2409=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_40','Highway roundabouts',#2396,$,$); +#2410=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_42','Intersections',#2396,$,$); +#2411=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_44','Junctions',#2396,$,$); +#2412=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_45','Lanes',#2396,$,$); +#2413=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_46','Lay-bys and passing places',#2396,$,$); +#2414=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_57','Non-motorized use crossings',#2396,$,$); +#2415=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_59','Ox-bow laybys',#2396,$,$); +#2416=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_62','Pedestrian crossings',#2396,$,$); +#2417=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_63','Pedestrian routes',#2396,$,$); +#2418=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_64','Pedestrian refuges and islands',#2396,$,$); +#2419=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_66','Police ramps',#2396,$,$); +#2420=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_70','Railway crossings',#2396,$,$); +#2421=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_71','Refuge areas',#2396,$,$); +#2422=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_72','Roadside rest areas',#2396,$,$); +#2423=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_74','Road sections',#2396,$,$); +#2424=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_77','Side reservations',#2396,$,$); +#2425=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_78','Side road carriageways',#2396,$,$); +#2426=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_80','Slip road carriageways',#2396,$,$); +#2427=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_81','Soft shoulders',#2396,$,$); +#2428=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_87','Taxi ranks',#2396,$,$); +#2429=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_90','Truck manoeuvring areas',#2396,$,$); +#2430=IFCCLASSIFICATIONREFERENCE($,'SL_80_35_94','Vaulted spaces',#2396,$,$); +#2431=IFCCLASSIFICATIONREFERENCE($,'SL_80_45','Vehicle storage spaces',#2357,$,$); +#2432=IFCCLASSIFICATIONREFERENCE($,'SL_80_45_09','Bus standing spaces',#2431,$,$); +#2433=IFCCLASSIFICATIONREFERENCE($,'SL_80_45_11','Car park attendant booths',#2431,$,$); +#2434=IFCCLASSIFICATIONREFERENCE($,'SL_80_45_13','Car park ramps',#2431,$,$); +#2435=IFCCLASSIFICATIONREFERENCE($,'SL_80_45_15','Cycle parking spaces',#2431,$,$); +#2436=IFCCLASSIFICATIONREFERENCE($,'SL_80_45_40','Indoor vehicle parking spaces',#2431,$,$); +#2437=IFCCLASSIFICATIONREFERENCE($,'SL_80_45_59','Outdoor vehicle parking spaces',#2431,$,$); +#2438=IFCCLASSIFICATIONREFERENCE($,'SL_80_45_91','Truck standing spaces',#2431,$,$); +#2439=IFCCLASSIFICATIONREFERENCE($,'SL_80_50','Railway spaces',#2357,$,$); +#2440=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_11','Carriage cleaning spaces',#2439,$,$); +#2441=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_24','Double sided platforms',#2439,$,$); +#2442=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_26','Engine fuelling areas',#2439,$,$); +#2443=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_27','Engine inspection pits',#2439,$,$); +#2444=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_28','Engine servicing areas',#2439,$,$); +#2445=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_29','Engine wash areas',#2439,$,$); +#2446=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_47','Light rail stops',#2439,$,$); +#2447=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_50','Marshalling yards',#2439,$,$); +#2448=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_58','Railway overpasses',#2439,$,$); +#2449=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_70','Rail repair spaces',#2439,$,$); +#2450=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_71','Railway side reservations',#2439,$,$); +#2451=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_72','Railway lines',#2439,$,$); +#2452=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_74','Railway sections',#2439,$,$); +#2453=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_77','Railway signal control spaces',#2439,$,$); +#2454=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_79','Signalling equipment room',#2439,$,$); +#2455=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_80','Single sided platforms',#2439,$,$); +#2456=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_85','Stabling yards',#2439,$,$); +#2457=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_88','Track paralleling huts',#2439,$,$); +#2458=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_90','Train stops',#2439,$,$); +#2459=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_92','Railway underpasses',#2439,$,$); +#2460=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_95','Wagon decontamination spaces',#2439,$,$); +#2461=IFCCLASSIFICATIONREFERENCE($,'SL_80_50_97','Wagon maintenance spaces',#2439,$,$); +#2462=IFCCLASSIFICATIONREFERENCE($,'SL_80_70','Marine and waterways transport spaces',#2357,$,$); +#2463=IFCCLASSIFICATIONREFERENCE($,'SL_80_70_11','Canal lock chambers',#2462,$,$); +#2464=IFCCLASSIFICATIONREFERENCE($,'SL_80_70_37','Harbour locks',#2462,$,$); +#2465=IFCCLASSIFICATIONREFERENCE($,'SL_80_90','Transport hubs',#2357,$,$); +#2466=IFCCLASSIFICATIONREFERENCE($,'SL_80_92','Grid systems',#2357,$,$); +#2467=IFCCLASSIFICATIONREFERENCE($,'SL_80_92_34','Geospatial grids',#2466,$,$); +#2468=IFCCLASSIFICATIONREFERENCE($,'SL_80_92_37','Horizontal alignment grids',#2466,$,$); +#2469=IFCCLASSIFICATIONREFERENCE($,'SL_80_92_94','Vertical alignment grids',#2466,$,$); +#2470=IFCCLASSIFICATIONREFERENCE($,'SL_80_94','Bridge and structure spaces',#2357,$,$); +#2471=IFCCLASSIFICATIONREFERENCE($,'SL_80_94_07','Bearing shelves',#2470,$,$); +#2472=IFCCLASSIFICATIONREFERENCE($,'SL_80_94_09','Bridge aprons',#2470,$,$); +#2473=IFCCLASSIFICATIONREFERENCE($,'SL_80_94_71','Retaining wall aprons',#2470,$,$); +#2474=IFCCLASSIFICATIONREFERENCE($,'SL_80_96','Tunnel and shaft spaces',#2357,$,$); +#2475=IFCCLASSIFICATIONREFERENCE($,'SL_80_96_15','Concourse tunnels',#2474,$,$); +#2476=IFCCLASSIFICATIONREFERENCE($,'SL_80_96_18','Crossover tunnels',#2474,$,$); +#2477=IFCCLASSIFICATIONREFERENCE($,'SL_80_96_20','Drift tunnel portals',#2474,$,$); +#2478=IFCCLASSIFICATIONREFERENCE($,'SL_80_96_58','Overrun tunnels',#2474,$,$); +#2479=IFCCLASSIFICATIONREFERENCE($,'SL_80_96_60','Passageway tunnels',#2474,$,$); +#2480=IFCCLASSIFICATIONREFERENCE($,'SL_80_96_64','Platform tunnels',#2474,$,$); +#2481=IFCCLASSIFICATIONREFERENCE($,'SL_80_96_78','Sidings tunnels',#2474,$,$); +#2482=IFCCLASSIFICATIONREFERENCE($,'SL_80_98','Transport kinematic envelopes',#2357,$,$); +#2483=IFCCLASSIFICATIONREFERENCE($,'SL_80_98_09','Bridge headrooms',#2482,$,$); +#2484=IFCCLASSIFICATIONREFERENCE($,'SL_80_98_15','Collapse radius',#2482,$,$); +#2485=IFCCLASSIFICATIONREFERENCE($,'SL_80_98_46','Lateral safety zones',#2482,$,$); +#2486=IFCCLASSIFICATIONREFERENCE($,'SL_80_98_48','Longitudinal safety zones',#2482,$,$); +#2487=IFCCLASSIFICATIONREFERENCE($,'SL_80_98_75','Safety clearance zones',#2482,$,$); +#2488=IFCCLASSIFICATIONREFERENCE($,'SL_80_98_85','Swept path areas',#2482,$,$); +#2489=IFCCLASSIFICATIONREFERENCE($,'SL_80_98_90','Tunnel headrooms',#2482,$,$); +#2490=IFCCLASSIFICATIONREFERENCE($,'SL_80_98_97','Working widths',#2482,$,$); +#2491=IFCCLASSIFICATIONREFERENCE($,'SL_90','General spaces',#1767,$,$); +#2492=IFCCLASSIFICATIONREFERENCE($,'SL_90_10','Circulation spaces',#2491,$,$); +#2493=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_02','Air locks',#2492,$,$); +#2494=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_04','Atriums',#2492,$,$); +#2495=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_08','Breezeways',#2492,$,$); +#2496=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_15','Corridors',#2492,$,$); +#2497=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_16','Covered walkways and internal bridges',#2492,$,$); +#2498=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_24','Drop-off and collection areas',#2492,$,$); +#2499=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_27','Entrance halls',#2492,$,$); +#2500=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_28','Escalators and travellators',#2492,$,$); +#2501=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_34','Goods conveyors',#2492,$,$); +#2502=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_36','Hallways',#2492,$,$); +#2503=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_46','Landings',#2492,$,$); +#2504=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_47','Lifts',#2492,$,$); +#2505=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_51','Lobbies',#2492,$,$); +#2506=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_64','Porches',#2492,$,$); +#2507=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_68','Public squares',#2492,$,$); +#2508=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_71','Retail circulation spaces',#2492,$,$); +#2509=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_77','Shelters',#2492,$,$); +#2510=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_87','Stairways',#2492,$,$); +#2511=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_94','Vestibules',#2492,$,$); +#2512=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_95','Walkways',#2492,$,$); +#2513=IFCCLASSIFICATIONREFERENCE($,'SL_90_10_96','Wheelchair circulation spaces',#2492,$,$); +#2514=IFCCLASSIFICATIONREFERENCE($,'SL_90_20','Common spaces',#2491,$,$); +#2515=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_01','Accident and emergency waiting rooms',#2514,$,$); +#2516=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_02','Air spaces',#2514,$,$); +#2517=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_04','Audience seating areas',#2514,$,$); +#2518=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_05','Audience standing areas',#2514,$,$); +#2519=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_08','Breakout spaces',#2514,$,$); +#2520=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_13','Changing rooms',#2514,$,$); +#2521=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_14','Cloakrooms',#2514,$,$); +#2522=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_15','Corporate boxes and VIP seating',#2514,$,$); +#2523=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_16','Customer service counter areas',#2514,$,$); +#2524=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_69','Queuing areas',#2514,$,$); +#2525=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_82','Spectator seating areas',#2514,$,$); +#2526=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_83','Spectator standing areas',#2514,$,$); +#2527=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_88','Temporary seating areas',#2514,$,$); +#2528=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_89','Ticket offices',#2514,$,$); +#2529=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_96','Waiting rooms',#2514,$,$); +#2530=IFCCLASSIFICATIONREFERENCE($,'SL_90_20_98','Work booths',#2514,$,$); +#2531=IFCCLASSIFICATIONREFERENCE($,'SL_90_30','Construction voids',#2491,$,$); +#2532=IFCCLASSIFICATIONREFERENCE($,'SL_90_30_25','Excavation volumes',#2531,$,$); +#2533=IFCCLASSIFICATIONREFERENCE($,'SL_90_30_30','Finishes allowances',#2531,$,$); +#2534=IFCCLASSIFICATIONREFERENCE($,'SL_90_30_80','Space proofing envelopes',#2531,$,$); +#2535=IFCCLASSIFICATIONREFERENCE($,'SL_90_30_90','Tolerance zones',#2531,$,$); +#2536=IFCCLASSIFICATIONREFERENCE($,'SL_90_40','General levels',#2491,$,$); +#2537=IFCCLASSIFICATIONREFERENCE($,'SL_90_40_46','Levels',#2536,$,$); +#2538=IFCCLASSIFICATIONREFERENCE($,'SL_90_50','Storage spaces',#2491,$,$); +#2539=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_04','Arms depots and armouries',#2538,$,$); +#2540=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_06','Baggage storage areas',#2538,$,$); +#2541=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_07','Battery stores',#2538,$,$); +#2542=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_08','Blood banks',#2538,$,$); +#2543=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_09','Boat storage spaces',#2538,$,$); +#2544=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_11','Cargo storage areas',#2538,$,$); +#2545=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_12','Car ports',#2538,$,$); +#2546=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_13','Chemicals stores',#2538,$,$); +#2547=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_14','Clothes stores',#2538,$,$); +#2548=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_15','Cold stores',#2538,$,$); +#2549=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_17','Cycle storage spaces',#2538,$,$); +#2550=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_24','Dry waste storage spaces',#2538,$,$); +#2551=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_25','Dungsteads',#2538,$,$); +#2552=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_26','Effluent tanks',#2538,$,$); +#2553=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_27','Equipment stores',#2538,$,$); +#2554=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_28','Explosives and ordnance storerooms',#2538,$,$); +#2555=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_30','Feed stores',#2538,$,$); +#2556=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_31','Flammable chemical stores',#2538,$,$); +#2557=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_32','Fuel storage areas',#2538,$,$); +#2558=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_33','Garages',#2538,$,$); +#2559=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_34','Gas storage spaces',#2538,$,$); +#2560=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_35','General storerooms',#2538,$,$); +#2561=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_36','Goods stores',#2538,$,$); +#2562=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_37','Grain stores',#2538,$,$); +#2563=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_38','Hazardous waste storage spaces',#2538,$,$); +#2564=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_44','Janitor stores',#2538,$,$); +#2565=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_45','Keg stores',#2538,$,$); +#2566=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_46','Larders and pantries',#2538,$,$); +#2567=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_47','Left luggage stores',#2538,$,$); +#2568=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_48','Locker rooms',#2538,$,$); +#2569=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_52','Mineral storage spaces',#2538,$,$); +#2570=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_54','Morgues',#2538,$,$); +#2571=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_55','Mortuaries',#2538,$,$); +#2572=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_58','Oil storage spaces',#2538,$,$); +#2573=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_65','Pharmaceutical stores',#2538,$,$); +#2574=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_70','Raw materials storage silos',#2538,$,$); +#2575=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_71','Raw materials storage spaces',#2538,$,$); +#2576=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_72','Raw materials storage tanks',#2538,$,$); +#2577=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_77','Secure storerooms',#2538,$,$); +#2578=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_80','Solid fuel storerooms',#2538,$,$); +#2579=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_84','Storage rooms',#2538,$,$); +#2580=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_88','Tissue and organ stores',#2538,$,$); +#2581=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_90','Vaults and strong rooms',#2538,$,$); +#2582=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_93','Walk-in wardrobes',#2538,$,$); +#2583=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_94','Waste gas storage spaces',#2538,$,$); +#2584=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_95','Waste liquids storage spaces',#2538,$,$); +#2585=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_96','Waste solids storage spaces',#2538,$,$); +#2586=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_97','Wet waste storage spaces',#2538,$,$); +#2587=IFCCLASSIFICATIONREFERENCE($,'SL_90_50_98','Wine cellars',#2538,$,$); +#2588=IFCCLASSIFICATIONREFERENCE($,'SL_90_60','Unoccupied voids',#2491,$,$); +#2589=IFCCLASSIFICATIONREFERENCE($,'SL_90_60_01','Access spaces',#2588,$,$); +#2590=IFCCLASSIFICATIONREFERENCE($,'SL_90_60_02','Air shafts',#2588,$,$); +#2591=IFCCLASSIFICATIONREFERENCE($,'SL_90_60_10','Cavities',#2588,$,$); +#2592=IFCCLASSIFICATIONREFERENCE($,'SL_90_60_12','Chimneys',#2588,$,$); +#2593=IFCCLASSIFICATIONREFERENCE($,'SL_90_60_13','Chutes',#2588,$,$); +#2594=IFCCLASSIFICATIONREFERENCE($,'SL_90_60_18','Crawl spaces',#2588,$,$); +#2595=IFCCLASSIFICATIONREFERENCE($,'SL_90_60_49','Lift pits',#2588,$,$); +#2596=IFCCLASSIFICATIONREFERENCE($,'SL_90_60_50','Lift shafts',#2588,$,$); +#2597=IFCCLASSIFICATIONREFERENCE($,'SL_90_60_51','Light wells',#2588,$,$); +#2598=IFCCLASSIFICATIONREFERENCE($,'SL_90_60_64','Platform voids',#2588,$,$); +#2599=IFCCLASSIFICATIONREFERENCE($,'SL_90_60_72','Roof surface spaces',#2588,$,$); +#2600=IFCCLASSIFICATIONREFERENCE($,'SL_90_60_74','Roof voids',#2588,$,$); +#2601=IFCCLASSIFICATIONREFERENCE($,'SL_90_90','Plant and control spaces',#2491,$,$); +#2602=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_01','Access floor voids',#2601,$,$); +#2603=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_08','Boiler rooms',#2601,$,$); +#2604=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_13','Ceiling voids',#2601,$,$); +#2605=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_15','Control rooms',#2601,$,$); +#2606=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_32','Furnace rooms',#2601,$,$); +#2607=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_42','Incinerator rooms',#2601,$,$); +#2608=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_48','Lift machine rooms',#2601,$,$); +#2609=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_64','Plant rooms',#2601,$,$); +#2610=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_77','Server rooms',#2601,$,$); +#2611=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_78','Services shafts',#2601,$,$); +#2612=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_85','Switch rooms',#2601,$,$); +#2613=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_87','Tank rooms',#2601,$,$); +#2614=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_90','Transformer rooms',#2601,$,$); +#2615=IFCCLASSIFICATIONREFERENCE($,'SL_90_90_96','Wall services voids',#2601,$,$); +#2616=IFCCLASSIFICATIONREFERENCE($,'EF','Elements/ functions',#2,$,$); +#2617=IFCCLASSIFICATIONREFERENCE($,'EF_15','Site elements',#2616,$,$); +#2618=IFCCLASSIFICATIONREFERENCE($,'EF_15_15','Construction sites',#2617,$,$); +#2619=IFCCLASSIFICATIONREFERENCE($,'EF_15_95','Work areas',#2617,$,$); +#2620=IFCCLASSIFICATIONREFERENCE($,'EF_20','Structural elements',#2616,$,$); +#2621=IFCCLASSIFICATIONREFERENCE($,'EF_20_05','Substructure',#2620,$,$); +#2622=IFCCLASSIFICATIONREFERENCE($,'EF_20_10','Superstructure',#2620,$,$); +#2623=IFCCLASSIFICATIONREFERENCE($,'EF_20_50','Bridge abutments and piers',#2620,$,$); +#2624=IFCCLASSIFICATIONREFERENCE($,'EF_25','Wall and barrier elements',#2616,$,$); +#2625=IFCCLASSIFICATIONREFERENCE($,'EF_25_10','Walls',#2624,$,$); +#2626=IFCCLASSIFICATIONREFERENCE($,'EF_25_30','Doors and windows',#2624,$,$); +#2627=IFCCLASSIFICATIONREFERENCE($,'EF_25_55','Barriers',#2624,$,$); +#2628=IFCCLASSIFICATIONREFERENCE($,'EF_30','Roofs, floor and paving elements',#2616,$,$); +#2629=IFCCLASSIFICATIONREFERENCE($,'EF_30_10','Roofs',#2628,$,$); +#2630=IFCCLASSIFICATIONREFERENCE($,'EF_30_20','Floors',#2628,$,$); +#2631=IFCCLASSIFICATIONREFERENCE($,'EF_30_60','Pavements',#2628,$,$); +#2632=IFCCLASSIFICATIONREFERENCE($,'EF_30_70','Bridge decks',#2628,$,$); +#2633=IFCCLASSIFICATIONREFERENCE($,'EF_35','Stairs and ramps',#2616,$,$); +#2634=IFCCLASSIFICATIONREFERENCE($,'EF_35_10','Stairs',#2633,$,$); +#2635=IFCCLASSIFICATIONREFERENCE($,'EF_35_20','Ramps',#2633,$,$); +#2636=IFCCLASSIFICATIONREFERENCE($,'EF_37','Tunnel, vessel and tower elements',#2616,$,$); +#2637=IFCCLASSIFICATIONREFERENCE($,'EF_37_16','Vessels and trenches',#2636,$,$); +#2638=IFCCLASSIFICATIONREFERENCE($,'EF_37_17','Towers, chimneys and masts',#2636,$,$); +#2639=IFCCLASSIFICATIONREFERENCE($,'EF_37_50','Tunnels and shafts',#2636,$,$); +#2640=IFCCLASSIFICATIONREFERENCE($,'EF_40','Signage, fittings, furnishings and equipment',#2616,$,$); +#2641=IFCCLASSIFICATIONREFERENCE($,'EF_40_10','Signage',#2640,$,$); +#2642=IFCCLASSIFICATIONREFERENCE($,'EF_40_20','Fittings',#2640,$,$); +#2643=IFCCLASSIFICATIONREFERENCE($,'EF_40_30','Furnishings',#2640,$,$); +#2644=IFCCLASSIFICATIONREFERENCE($,'EF_40_40','Equipment',#2640,$,$); +#2645=IFCCLASSIFICATIONREFERENCE($,'EF_45','Flora and fauna elements',#2616,$,$); +#2646=IFCCLASSIFICATIONREFERENCE($,'EF_45_10','Planted elements',#2645,$,$); +#2647=IFCCLASSIFICATIONREFERENCE($,'EF_45_20','Grassed elements',#2645,$,$); +#2648=IFCCLASSIFICATIONREFERENCE($,'EF_45_30','Fauna elements',#2645,$,$); +#2649=IFCCLASSIFICATIONREFERENCE($,'EF_45_75','Fish and eel pass elements',#2645,$,$); +#2650=IFCCLASSIFICATIONREFERENCE($,'EF_50','Waste disposal functions',#2616,$,$); +#2651=IFCCLASSIFICATIONREFERENCE($,'EF_50_10','Gas waste collection',#2650,$,$); +#2652=IFCCLASSIFICATIONREFERENCE($,'EF_50_20','Wet waste collection',#2650,$,$); +#2653=IFCCLASSIFICATIONREFERENCE($,'EF_50_30','Drainage collection',#2650,$,$); +#2654=IFCCLASSIFICATIONREFERENCE($,'EF_50_40','Dry waste collection',#2650,$,$); +#2655=IFCCLASSIFICATIONREFERENCE($,'EF_50_50','Gas waste treatment and disposal',#2650,$,$); +#2656=IFCCLASSIFICATIONREFERENCE($,'EF_50_60','Wet waste treatment and disposal',#2650,$,$); +#2657=IFCCLASSIFICATIONREFERENCE($,'EF_50_70','Drainage treatment and disposal',#2650,$,$); +#2658=IFCCLASSIFICATIONREFERENCE($,'EF_50_75','Wastewater treatment and disposal',#2650,$,$); +#2659=IFCCLASSIFICATIONREFERENCE($,'EF_50_80','Dry waste treatment and disposal',#2650,$,$); +#2660=IFCCLASSIFICATIONREFERENCE($,'EF_55','Piped supply functions',#2616,$,$); +#2661=IFCCLASSIFICATIONREFERENCE($,'EF_55_05','Gas extraction and treatment',#2660,$,$); +#2662=IFCCLASSIFICATIONREFERENCE($,'EF_55_10','Liquid fuel extraction and treatment',#2660,$,$); +#2663=IFCCLASSIFICATIONREFERENCE($,'EF_55_15','Water extraction and treatment',#2660,$,$); +#2664=IFCCLASSIFICATIONREFERENCE($,'EF_55_20','Gas supply',#2660,$,$); +#2665=IFCCLASSIFICATIONREFERENCE($,'EF_55_30','Fire extinguishing supply',#2660,$,$); +#2666=IFCCLASSIFICATIONREFERENCE($,'EF_55_40','Steam supply',#2660,$,$); +#2667=IFCCLASSIFICATIONREFERENCE($,'EF_55_50','Liquid fuel supply',#2660,$,$); +#2668=IFCCLASSIFICATIONREFERENCE($,'EF_55_60','Process liquid supply',#2660,$,$); +#2669=IFCCLASSIFICATIONREFERENCE($,'EF_55_70','Water supply',#2660,$,$); +#2670=IFCCLASSIFICATIONREFERENCE($,'EF_55_90','Piped solids supply',#2660,$,$); +#2671=IFCCLASSIFICATIONREFERENCE($,'EF_60','Heating, cooling and refrigeration functions',#2616,$,$); +#2672=IFCCLASSIFICATIONREFERENCE($,'EF_60_30','Rail and paving heating',#2671,$,$); +#2673=IFCCLASSIFICATIONREFERENCE($,'EF_60_40','Space heating and cooling',#2671,$,$); +#2674=IFCCLASSIFICATIONREFERENCE($,'EF_60_60','Refrigeration',#2671,$,$); +#2675=IFCCLASSIFICATIONREFERENCE($,'EF_60_80','Drying',#2671,$,$); +#2676=IFCCLASSIFICATIONREFERENCE($,'EF_65','Ventilation and air conditioning functions',#2616,$,$); +#2677=IFCCLASSIFICATIONREFERENCE($,'EF_65_40','Ventilation',#2676,$,$); +#2678=IFCCLASSIFICATIONREFERENCE($,'EF_65_80','Air conditioning',#2676,$,$); +#2679=IFCCLASSIFICATIONREFERENCE($,'EF_70','Electrical power and lighting functions',#2616,$,$); +#2680=IFCCLASSIFICATIONREFERENCE($,'EF_70_10','Electrical power generation',#2679,$,$); +#2681=IFCCLASSIFICATIONREFERENCE($,'EF_70_30','Electricity distribution and transmission',#2679,$,$); +#2682=IFCCLASSIFICATIONREFERENCE($,'EF_70_80','Lighting',#2679,$,$); +#2683=IFCCLASSIFICATIONREFERENCE($,'EF_75','Communications, security, safety and protection functions',#2616,$,$); +#2684=IFCCLASSIFICATIONREFERENCE($,'EF_75_10','Communication',#2683,$,$); +#2685=IFCCLASSIFICATIONREFERENCE($,'EF_75_30','Signalling',#2683,$,$); +#2686=IFCCLASSIFICATIONREFERENCE($,'EF_75_40','Security',#2683,$,$); +#2687=IFCCLASSIFICATIONREFERENCE($,'EF_75_50','Safety and protection',#2683,$,$); +#2688=IFCCLASSIFICATIONREFERENCE($,'EF_75_60','Environmental safety',#2683,$,$); +#2689=IFCCLASSIFICATIONREFERENCE($,'EF_75_70','Control and management',#2683,$,$); +#2690=IFCCLASSIFICATIONREFERENCE($,'EF_75_80','Protection',#2683,$,$); +#2691=IFCCLASSIFICATIONREFERENCE($,'EF_80','Transport functions',#2616,$,$); +#2692=IFCCLASSIFICATIONREFERENCE($,'EF_80_10','Cable transport',#2691,$,$); +#2693=IFCCLASSIFICATIONREFERENCE($,'EF_80_20','Conveyors',#2691,$,$); +#2694=IFCCLASSIFICATIONREFERENCE($,'EF_80_30','Cranes and hoists',#2691,$,$); +#2695=IFCCLASSIFICATIONREFERENCE($,'EF_80_50','Lifts',#2691,$,$); +#2696=IFCCLASSIFICATIONREFERENCE($,'EF_80_70','Rail tracks',#2691,$,$); +#2697=IFCCLASSIFICATIONREFERENCE($,'Ss','Systems',#2,$,$); +#2698=IFCCLASSIFICATIONREFERENCE($,'Ss_15','Earthworks, remediation and temporary systems',#2697,$,$); +#2699=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10','Groundworks and earthworks systems',#2698,$,$); +#2700=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_30','Excavating and filling systems',#2699,$,$); +#2701=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_30_05','Backfill systems',#2700,$,$); +#2702=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_30_25','Earthworks excavating systems',#2700,$,$); +#2703=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_30_27','Earthworks filling systems',#2700,$,$); +#2704=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_30_29','Earthworks filling systems around trees',#2700,$,$); +#2705=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_30_31','Earthworks filling systems behind retaining walls',#2700,$,$); +#2706=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_30_65','Puddled clay lining systems',#2700,$,$); +#2707=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_30_90','Topsoil filling systems',#2700,$,$); +#2708=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_33','Ground gas disposal systems',#2699,$,$); +#2709=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_33_34','Ground gas collection and venting systems',#2708,$,$); +#2710=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_35','Ground remediation systems',#2699,$,$); +#2711=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_35_07','Bioremediation systems',#2710,$,$); +#2712=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_45','Landfill systems',#2699,$,$); +#2713=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_76','Site waste disposal systems',#2699,$,$); +#2714=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_76_21','Dewatering systems',#2713,$,$); +#2715=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_78','Slurry wall systems',#2699,$,$); +#2716=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_80','Stabilization systems',#2699,$,$); +#2717=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_80_33','Erosion control systems',#2716,$,$); +#2718=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_80_70','Rock bolting and dowelling systems',#2716,$,$); +#2719=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_80_80','Soil nailing systems',#2716,$,$); +#2720=IFCCLASSIFICATIONREFERENCE($,'Ss_15_10_80_85','Subterranean void filling systems',#2716,$,$); +#2721=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30','Remediation, repair and renovation systems',#2698,$,$); +#2722=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_10','Building services remediation systems',#2721,$,$); +#2723=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_12','Ceramics repair and renovation systems',#2721,$,$); +#2724=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_15','Concrete and masonry cleaning systems',#2721,$,$); +#2725=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_15_15','Concrete cleaning systems',#2724,$,$); +#2726=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_15_50','Masonry cleaning systems',#2724,$,$); +#2727=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_15_65','Preliminary concrete cleaning systems',#2724,$,$); +#2728=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_15_66','Preliminary masonry cleaning systems',#2724,$,$); +#2729=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_17','Concrete repair and renovation systems',#2721,$,$); +#2730=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_17_10','Bonded steel plate repair systems',#2729,$,$); +#2731=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_17_12','Concrete crack repair or filling systems',#2729,$,$); +#2732=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_17_14','Concrete mortar or overlay systems',#2729,$,$); +#2733=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_17_16','Concrete protective coating systems',#2729,$,$); +#2734=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_17_18','Concrete repair systems',#2729,$,$); +#2735=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_17_85','Sprayed concrete repair systems',#2729,$,$); +#2736=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_32','Fungus and beetle eradication systems',#2721,$,$); +#2737=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_32_05','Beetle eradication systems',#2736,$,$); +#2738=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_32_15','Combined fungus and beetle treatment systems',#2736,$,$); +#2739=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_32_35','Hot air infestation treatment systems',#2736,$,$); +#2740=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_32_50','Masonry fungus treatment systems',#2736,$,$); +#2741=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_32_85','Termite treatment systems',#2736,$,$); +#2742=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_32_90','Timber fungus treatment systems',#2736,$,$); +#2743=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_33','Glass repair and renovation systems',#2721,$,$); +#2744=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_50','Masonry repair and renovation systems',#2721,$,$); +#2745=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_50_11','Cavity wall insulation systems',#2744,$,$); +#2746=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_50_50','Masonry repair systems',#2744,$,$); +#2747=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_50_53','Mortar joint repair systems',#2744,$,$); +#2748=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_50_55','Mortar repointing systems',#2744,$,$); +#2749=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_52','Metal repair and renovation systems',#2721,$,$); +#2750=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_52_03','Aluminium repair systems',#2749,$,$); +#2751=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_52_15','Copper repair systems',#2749,$,$); +#2752=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_52_42','Iron repair systems',#2749,$,$); +#2753=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_52_46','Lead repair systems',#2749,$,$); +#2754=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_52_84','Steel repair systems',#2749,$,$); +#2755=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_65','Pipeline renovation systems',#2721,$,$); +#2756=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_65_15','Close fit plastics pipe lining systems',#2755,$,$); +#2757=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_65_17','Continuous plastics pipe lining systems',#2755,$,$); +#2758=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_65_20','Cured in place lining systems',#2755,$,$); +#2759=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_65_65','Preformed lining systems',#2755,$,$); +#2760=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_65_72','Rigidly anchored plastics inner layer (RAPL) lining systems',#2755,$,$); +#2761=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_65_80','Spray lining systems',#2755,$,$); +#2762=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_65_81','Spirally wound plastics pipe lining systems',#2755,$,$); +#2763=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_90','Timber repair and renovation systems',#2721,$,$); +#2764=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_90_82','Timber end lap repair systems',#2763,$,$); +#2765=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_90_84','Timber joint strengthening systems',#2763,$,$); +#2766=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_90_86','Timber section repair external splice systems',#2763,$,$); +#2767=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_90_88','Timber section repair internal reinforcement systems',#2763,$,$); +#2768=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_90_90','Timber section strengthening external reinforcement systems',#2763,$,$); +#2769=IFCCLASSIFICATIONREFERENCE($,'Ss_15_30_90_92','Timber section strengthening internal reinforcement systems',#2763,$,$); +#2770=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95','Temporary works systems',#2698,$,$); +#2771=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_15','Temporary preparatory works systems',#2770,$,$); +#2772=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_15_10','Borehole systems',#2771,$,$); +#2773=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_17','Temporary protection systems',#2770,$,$); +#2774=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_17_90','Temporary backfill systems',#2773,$,$); +#2775=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_20','Temporary whole entity structural works systems',#2770,$,$); +#2776=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_20_30','Flying shores systems',#2775,$,$); +#2777=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_20_32','Framed retention structure systems',#2775,$,$); +#2778=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_20_70','Raking shores systems',#2775,$,$); +#2779=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_20_72','Retention structure systems',#2775,$,$); +#2780=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_20_75','Scaffold retention structure systems',#2775,$,$); +#2781=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_20_87','Thrust pit systems',#2775,$,$); +#2782=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_25','Temporary wall and barrier works systems',#2770,$,$); +#2783=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_30','Temporary roof, floor and paving works systems',#2770,$,$); +#2784=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_32','Temporary water and land management systems',#2770,$,$); +#2785=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_32_85','Sedimentation ponds',#2784,$,$); +#2786=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_35','Temporary fixed access, tunnel, shaft, vessel and tower works systems',#2770,$,$); +#2787=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_40','Temporary signage and fittings, furnishings and equipment (FF&E) works systems',#2770,$,$); +#2788=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_45','Temporary flora and fauna systems',#2770,$,$); +#2789=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_45_42','Intercropping systems',#2788,$,$); +#2790=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_45_85','Spoil heap temporary crop systems',#2788,$,$); +#2791=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_45_90','Topsoil heap temporary crop systems',#2788,$,$); +#2792=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_55','Temporary piped supply works systems',#2770,$,$); +#2793=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_55_90','Tunnelling compressed air systems',#2792,$,$); +#2794=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_60','Temporary heating, cooling and refrigeration works systems',#2770,$,$); +#2795=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_65','Temporary ventilation and air conditioning works systems',#2770,$,$); +#2796=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_70','Temporary electrical works systems',#2770,$,$); +#2797=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_75','Temporary communications, security, safety, control and protection works systems',#2770,$,$); +#2798=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_80','Temporary pavement works systems',#2770,$,$); +#2799=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_80_02','Temporary access road systems',#2798,$,$); +#2800=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_80_72','Temporary roadwork systems',#2798,$,$); +#2801=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_85','Temporary process engineering works systems',#2770,$,$); +#2802=IFCCLASSIFICATIONREFERENCE($,'Ss_15_95_90','Temporary soft facility management works services',#2770,$,$); +#2803=IFCCLASSIFICATIONREFERENCE($,'Ss_20','Structural systems',#2697,$,$); +#2804=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05','Substructure systems',#2803,$,$); +#2805=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_15','Concrete foundation systems',#2804,$,$); +#2806=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_15_65','Precast concrete pad and strip foundation systems',#2805,$,$); +#2807=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_15_70','Reinforced concrete pad and strip foundation systems',#2805,$,$); +#2808=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_15_71','Reinforced concrete pilecap and ground beam foundation systems',#2805,$,$); +#2809=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_15_72','Reinforced concrete raft foundation systems',#2805,$,$); +#2810=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_15_80','Steel ground beam foundation systems',#2805,$,$); +#2811=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_15_90','Unreinforced concrete foundation systems for cast in products',#2805,$,$); +#2812=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_15_91','Unreinforced concrete pad and strip foundation systems',#2805,$,$); +#2813=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_15_92','Unreinforced concrete trench fill foundation systems',#2805,$,$); +#2814=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_50','Minor concrete substructure systems',#2804,$,$); +#2815=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_50_15','Concrete haunching systems',#2814,$,$); +#2816=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_50_65','Precast concrete foundation and plinth systems',#2814,$,$); +#2817=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_50_70','Reinforced concrete base or foundation systems',#2814,$,$); +#2818=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_50_92','Unreinforced concrete foundation with cast in products systems',#2814,$,$); +#2819=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_50_93','Unreinforced concrete foundation and plinth systems',#2814,$,$); +#2820=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_65','Piling systems',#2804,$,$); +#2821=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_65_24','Driven precast or prestressed concrete piling systems',#2820,$,$); +#2822=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_65_40','In situ concrete augered piling systems',#2820,$,$); +#2823=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_65_41','In situ concrete bored piling systems',#2820,$,$); +#2824=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_65_42','In situ concrete cased displacement piling systems',#2820,$,$); +#2825=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_65_43','In situ concrete displacement piling systems',#2820,$,$); +#2826=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_65_44','In situ concrete mini-piling or micro-piling systems',#2820,$,$); +#2827=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_65_64','Plunge column piling systems',#2820,$,$); +#2828=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_65_76','Screw piling systems',#2820,$,$); +#2829=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_65_84','Steel bearing pile systems',#2820,$,$); +#2830=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_65_89','Timber piling systems',#2820,$,$); +#2831=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_80','Structural grouting systems',#2804,$,$); +#2832=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_80_12','Cementitious grout systems',#2831,$,$); +#2833=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_80_57','Non-cementitious grout systems',#2831,$,$); +#2834=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_80_71','Retaining wall cementitious grout systems',#2831,$,$); +#2835=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_80_73','Retaining wall self-hardening slurry systems',#2831,$,$); +#2836=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_90','Underpinning systems',#2804,$,$); +#2837=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_90_10','Beam and pier unreinforced concrete underpinning systems',#2836,$,$); +#2838=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_90_35','Grouted underpinning systems',#2836,$,$); +#2839=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_90_45','Jacked pile underpinning systems',#2836,$,$); +#2840=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_90_46','Jet grouted underpinning systems',#2836,$,$); +#2841=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_90_50','Mass concrete underpinning systems',#2836,$,$); +#2842=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_90_60','Pile and cantilever support underpinning systems',#2836,$,$); +#2843=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_90_61','Pile and needle underpinning systems',#2836,$,$); +#2844=IFCCLASSIFICATIONREFERENCE($,'Ss_20_05_90_70','Raking pile underpinning systems',#2836,$,$); +#2845=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10','Structural frame systems',#2803,$,$); +#2846=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_30','Bridge structure systems',#2845,$,$); +#2847=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_30_30','Footbridge systems',#2846,$,$); +#2848=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_30_65','Pipe bridge systems',#2846,$,$); +#2849=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_60','Prefabricated framed and panelled structures',#2845,$,$); +#2850=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_60_34','Glazed structural systems',#2849,$,$); +#2851=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_60_60','Panelled and framed structural systems',#2849,$,$); +#2852=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_60_84','Structural insulated panel systems',#2849,$,$); +#2853=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_65','Prefabricated room systems',#2845,$,$); +#2854=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_65_15','Composite pods',#2853,$,$); +#2855=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_65_17','Concrete pods',#2853,$,$); +#2856=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_65_65','Polypropylene pods',#2853,$,$); +#2857=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_70','Shelter systems',#2845,$,$); +#2858=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_70_03','Animal shelter systems',#2857,$,$); +#2859=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_70_62','People shelter systems',#2857,$,$); +#2860=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_70_64','Plant shelter systems',#2857,$,$); +#2861=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_70_84','Storage shelter systems',#2857,$,$); +#2862=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_75','Structural framing systems',#2845,$,$); +#2863=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_75_15','Concrete framing systems',#2862,$,$); +#2864=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_75_35','Heavy steel framing systems',#2862,$,$); +#2865=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_75_45','Light steel framing systems',#2862,$,$); +#2866=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_75_65','Precast reinforced concrete framing systems',#2862,$,$); +#2867=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_75_70','In situ reinforced concrete framing systems',#2862,$,$); +#2868=IFCCLASSIFICATIONREFERENCE($,'Ss_20_10_75_85','Timber framing systems',#2862,$,$); +#2869=IFCCLASSIFICATIONREFERENCE($,'Ss_20_20','Structural beams',#2803,$,$); +#2870=IFCCLASSIFICATIONREFERENCE($,'Ss_20_20_75','Structural beam systems',#2869,$,$); +#2871=IFCCLASSIFICATIONREFERENCE($,'Ss_20_20_75_15','Concrete beam systems',#2870,$,$); +#2872=IFCCLASSIFICATIONREFERENCE($,'Ss_20_20_75_80','Steel beam systems',#2870,$,$); +#2873=IFCCLASSIFICATIONREFERENCE($,'Ss_20_20_75_85','Timber beam systems',#2870,$,$); +#2874=IFCCLASSIFICATIONREFERENCE($,'Ss_20_30','Structural columns',#2803,$,$); +#2875=IFCCLASSIFICATIONREFERENCE($,'Ss_20_30_75','Structural column systems',#2874,$,$); +#2876=IFCCLASSIFICATIONREFERENCE($,'Ss_20_30_75_15','Concrete column systems',#2875,$,$); +#2877=IFCCLASSIFICATIONREFERENCE($,'Ss_20_30_75_50','Masonry column systems',#2875,$,$); +#2878=IFCCLASSIFICATIONREFERENCE($,'Ss_20_30_75_80','Steel column systems',#2875,$,$); +#2879=IFCCLASSIFICATIONREFERENCE($,'Ss_20_30_75_85','Timber column systems',#2875,$,$); +#2880=IFCCLASSIFICATIONREFERENCE($,'Ss_20_40','Structural sheet and cable systems',#2803,$,$); +#2881=IFCCLASSIFICATIONREFERENCE($,'Ss_20_40_07','Bridge suspension cable systems',#2880,$,$); +#2882=IFCCLASSIFICATIONREFERENCE($,'Ss_20_40_07_11','Cable stayed bridge cable systems',#2881,$,$); +#2883=IFCCLASSIFICATIONREFERENCE($,'Ss_20_40_07_85','Suspension bridge cable systems',#2881,$,$); +#2884=IFCCLASSIFICATIONREFERENCE($,'Ss_20_40_10','Building cable systems',#2880,$,$); +#2885=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50','Bridge abutment and pier systems',#2803,$,$); +#2886=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_10','Abutment systems',#2885,$,$); +#2887=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_10_10','Bank seat abutments',#2886,$,$); +#2888=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_10_30','Embedded retaining wall bridge abutments',#2886,$,$); +#2889=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_10_40','Integral abutments',#2886,$,$); +#2890=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_10_50','Masonry bridge abutments',#2886,$,$); +#2891=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_10_70','Reinforced concrete bridge abutments',#2886,$,$); +#2892=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_10_80','Sheet piled bridge abutments',#2886,$,$); +#2893=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_10_85','Spill-through abutments',#2886,$,$); +#2894=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_10_90','Tied embedded retaining wall bridge abutments',#2886,$,$); +#2895=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_10_95','Wing wall systems',#2886,$,$); +#2896=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_20','Bridge pier systems',#2885,$,$); +#2897=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_20_50','Masonry bridge piers',#2896,$,$); +#2898=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_20_70','Reinforced concrete bridge piers',#2896,$,$); +#2899=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_30','Abutment and pier component systems',#2885,$,$); +#2900=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_30_11','Capping beam systems',#2899,$,$); +#2901=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_30_37','Headwall systems',#2899,$,$); +#2902=IFCCLASSIFICATIONREFERENCE($,'Ss_20_50_30_80','Spandrel wall systems',#2899,$,$); +#2903=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60','Retaining wall systems',#2803,$,$); +#2904=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_30','Embedded retaining wall systems',#2903,$,$); +#2905=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_30_03','Anchored steel sheet pile embedded retaining wall systems',#2904,$,$); +#2906=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_30_08','Bored king post embedded retaining wall systems',#2904,$,$); +#2907=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_30_13','Combi retaining wall systems',#2904,$,$); +#2908=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_30_15','Contiguous bored pile embedded retaining wall systems',#2904,$,$); +#2909=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_30_24','Driven king post embedded retaining wall systems',#2904,$,$); +#2910=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_30_70','Reinforced concrete diaphragm retaining wall systems',#2904,$,$); +#2911=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_30_80','Secant pile embedded retaining wall systems',#2904,$,$); +#2912=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_30_83','Slurry diaphragm embedded retaining wall systems',#2904,$,$); +#2913=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_30_85','Steel sheet pile embedded retaining wall systems',#2904,$,$); +#2914=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_30_92','Unreinforced concrete diaphragm retaining wall systems',#2904,$,$); +#2915=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_35','Gravity retaining wall systems',#2903,$,$); +#2916=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_35_10','Caged rock unit (gabion) retaining wall systems',#2915,$,$); +#2917=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_35_13','Concrete bagwork retaining wall systems',#2915,$,$); +#2918=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_35_15','Crib retaining wall systems',#2915,$,$); +#2919=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_35_25','Drystack masonry unit retaining wall systems',#2915,$,$); +#2920=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_35_50','Masonry retaining wall systems',#2915,$,$); +#2921=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_35_66','Precast concrete stem wall retaining wall systems',#2915,$,$); +#2922=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_35_70','Reinforced concrete retaining wall systems',#2915,$,$); +#2923=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_35_72','Reinforced earth retaining wall systems',#2915,$,$); +#2924=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_35_90','Timber retaining wall systems',#2915,$,$); +#2925=IFCCLASSIFICATIONREFERENCE($,'Ss_20_60_35_91','Tyre bale retaining wall systems',#2915,$,$); +#2926=IFCCLASSIFICATIONREFERENCE($,'Ss_20_70','Structure covering and finishing systems',#2803,$,$); +#2927=IFCCLASSIFICATIONREFERENCE($,'Ss_20_70_15','Concrete protection systems',#2926,$,$); +#2928=IFCCLASSIFICATIONREFERENCE($,'Ss_20_70_65','Protective painting systems',#2926,$,$); +#2929=IFCCLASSIFICATIONREFERENCE($,'Ss_20_70_80','Steel encasement systems',#2926,$,$); +#2930=IFCCLASSIFICATIONREFERENCE($,'Ss_20_80','Structure accessory systems',#2803,$,$); +#2931=IFCCLASSIFICATIONREFERENCE($,'Ss_20_80_60','Permanent formwork systems',#2930,$,$); +#2932=IFCCLASSIFICATIONREFERENCE($,'Ss_20_95','Temporary structural systems',#2803,$,$); +#2933=IFCCLASSIFICATIONREFERENCE($,'Ss_25','Wall and barrier systems',#2697,$,$); +#2934=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10','Framed wall systems',#2933,$,$); +#2935=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_20','Curtain walling systems',#2934,$,$); +#2936=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_20_85','Stick curtain walling systems',#2935,$,$); +#2937=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_20_90','Unitized curtain walling systems',#2935,$,$); +#2938=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_30','Framed partition systems',#2934,$,$); +#2939=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_30_35','Gypsum board partition systems',#2938,$,$); +#2940=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_30_70','Rigid sheet partition systems',#2938,$,$); +#2941=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_32','Framed wall structure systems',#2934,$,$); +#2942=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_32_03','Aluminium wall framing systems',#2941,$,$); +#2943=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_32_35','Heavy steel wall framing systems',#2941,$,$); +#2944=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_32_45','Light steel wall framing systems',#2941,$,$); +#2945=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_32_58','Plastics wall framing systems',#2941,$,$); +#2946=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_32_90','Timber wall framing systems',#2941,$,$); +#2947=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_35','Framed glazed systems',#2934,$,$); +#2948=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_35_35','Glazed screen systems',#2947,$,$); +#2949=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_35_95','Vertical patent glazing systems',#2947,$,$); +#2950=IFCCLASSIFICATIONREFERENCE($,'Ss_25_10_35_97','Window wall glazed screen systems',#2947,$,$); +#2951=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11','Monolithic wall structure systems',#2933,$,$); +#2952=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11_13','Cob wall systems',#2951,$,$); +#2953=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11_15','Concrete form masonry unit wall systems',#2951,$,$); +#2954=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11_16','Concrete wall systems',#2951,$,$); +#2955=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11_16_65','Precast concrete wall systems',#2954,$,$); +#2956=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11_16_70','Reinforced concrete wall structure systems',#2954,$,$); +#2957=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11_16_80','Sprayed concrete wall structure systems',#2954,$,$); +#2958=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11_70','Rammed earth wall systems',#2951,$,$); +#2959=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11_70_55','Non-stabilized rammed earth wall systems',#2958,$,$); +#2960=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11_70_83','Stabilized rammed earth plinth systems',#2958,$,$); +#2961=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11_70_85','Stabilized rammed earth wall systems',#2958,$,$); +#2962=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11_90','Timber wall systems',#2951,$,$); +#2963=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11_90_15','Cross-laminated timber wall systems',#2962,$,$); +#2964=IFCCLASSIFICATIONREFERENCE($,'Ss_25_11_90_96','Wood log wall systems',#2962,$,$); +#2965=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12','Panel wall structure systems',#2933,$,$); +#2966=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_10','Brick panel wall systems',#2965,$,$); +#2967=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_15','Concrete panel wall systems',#2965,$,$); +#2968=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_60','Panel enclosure systems',#2965,$,$); +#2969=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_60_30','Fully-framed panel cubicle systems',#2968,$,$); +#2970=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_60_60','Panel cubicle systems',#2968,$,$); +#2971=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_60_65','Privacy screen systems',#2968,$,$); +#2972=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_65','Panel partition systems',#2965,$,$); +#2973=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_65_50','Media wall systems',#2972,$,$); +#2974=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_65_55','Mesh panel partition systems',#2972,$,$); +#2975=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_65_60','Plasterboard laminated partition systems',#2972,$,$); +#2976=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_65_65','Plasterboard panel partition systems',#2972,$,$); +#2977=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_65_70','Relocatable partition and ceiling systems',#2972,$,$); +#2978=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_65_75','Relocatable partition systems',#2972,$,$); +#2979=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_65_85','Storage wall systems',#2972,$,$); +#2980=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_80','Structural glass wall systems',#2965,$,$); +#2981=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_80_65','Point-fixed structural glass wall systems',#2980,$,$); +#2982=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_80_83','Stacked structural glass wall systems',#2980,$,$); +#2983=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_80_85','Suspended structural glass wall systems',#2980,$,$); +#2984=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_85','Structural steel panel wall systems',#2965,$,$); +#2985=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_85_60','Prefabricated metal wall systems',#2984,$,$); +#2986=IFCCLASSIFICATIONREFERENCE($,'Ss_25_12_85_63','Profile metal sheet wall systems',#2984,$,$); +#2987=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13','Unit wall structure systems',#2933,$,$); +#2988=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_05','Adobe block wall systems',#2987,$,$); +#2989=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_24','Dry stone wall systems',#2987,$,$); +#2990=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_30','Gabion wall systems',#2987,$,$); +#2991=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_33','Glass wall systems',#2987,$,$); +#2992=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_33_33','Glass block wall systems',#2991,$,$); +#2993=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_33_64','Prefabricated glass block wall systems',#2991,$,$); +#2994=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_35','Gypsum block wall systems',#2987,$,$); +#2995=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_45','Lead brick wall systems',#2987,$,$); +#2996=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_50','Masonry wall systems',#2987,$,$); +#2997=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_50_49','Masonry exposed feature systems',#2996,$,$); +#2998=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_50_51','Masonry wall leaf systems',#2996,$,$); +#2999=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_50_54','Masonry free-standing wall leaf systems',#2996,$,$); +#3000=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_50_56','Masonry internal partition systems',#2996,$,$); +#3001=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_70','Reinforced masonry wall systems',#2987,$,$); +#3002=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_70_71','Reinforced masonry wall leaf systems',#3001,$,$); +#3003=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_70_74','Reinforced masonry free-standing wall leaf systems',#3001,$,$); +#3004=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_70_76','Reinforced masonry internal partition systems',#3001,$,$); +#3005=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_85','Straw bale wall systems',#2987,$,$); +#3006=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_85_30','Framed straw bale wall systems',#3005,$,$); +#3007=IFCCLASSIFICATIONREFERENCE($,'Ss_25_13_85_95','Unframed straw bale wall systems',#3005,$,$); +#3008=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14','Fence systems',#2933,$,$); +#3009=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_30','Framed fence systems',#3008,$,$); +#3010=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_55','Monolithic fence systems',#3008,$,$); +#3011=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63','Post, rail and board fence systems',#3008,$,$); +#3012=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_06','Bespoke fencing systems',#3011,$,$); +#3013=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_08','Board or palisade fencing systems',#3011,$,$); +#3014=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_11','Carbon steel continuous bar fencing systems',#3011,$,$); +#3015=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_51','Metal post and rail fencing systems',#3011,$,$); +#3016=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_52','Metal vertical pale fencing systems',#3011,$,$); +#3017=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_56','Natural hurdle fencing systems',#3011,$,$); +#3018=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_62','Post and panel fencing systems',#3011,$,$); +#3019=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_63','Post and rail fencing systems',#3011,$,$); +#3020=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_64','Precast concrete palisade fencing systems',#3011,$,$); +#3021=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_65','Precast concrete post and panel fencing systems',#3011,$,$); +#3022=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_66','Precast concrete post and rail fencing systems',#3011,$,$); +#3023=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_67','Prefabricated wood or plastics panel fencing systems',#3011,$,$); +#3024=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_84','Steel hurdle fencing systems',#3011,$,$); +#3025=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_85','Steel palisade panel fencing systems',#3011,$,$); +#3026=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_86','Steel vertical bar fencing systems',#3011,$,$); +#3027=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_95','Wood close boarded fencing systems',#3011,$,$); +#3028=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_96','Wood palisade fencing systems',#3011,$,$); +#3029=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_97','Wood post and rail fencing systems',#3011,$,$); +#3030=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_63_98','Wrought iron panel fencing systems',#3011,$,$); +#3031=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_67','Post, wire and mesh fence systems',#3008,$,$); +#3032=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_67_12','Chain link fencing systems',#3031,$,$); +#3033=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_67_14','Cleft chestnut pale fencing systems',#3031,$,$); +#3034=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_67_15','Continuous mesh fencing systems',#3031,$,$); +#3035=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_67_24','Dropper pattern strained wire fencing systems',#3031,$,$); +#3036=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_67_27','Electric fencing systems',#3031,$,$); +#3037=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_67_28','Electric security fencing systems',#3031,$,$); +#3038=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_67_33','General pattern strained wire fencing systems',#3031,$,$); +#3039=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_67_34','General pattern wire mesh fencing systems',#3031,$,$); +#3040=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_67_51','Metal mesh panel fencing systems',#3031,$,$); +#3041=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_67_70','Rope or chain fencing systems',#3031,$,$); +#3042=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_67_80','Spring steel and high tensile wire mesh fencing systems',#3031,$,$); +#3043=IFCCLASSIFICATIONREFERENCE($,'Ss_25_14_67_97','Wire fencing systems',#3031,$,$); +#3044=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15','Fixed pedestrian barrier systems',#2933,$,$); +#3045=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60','Pedestrian safety barrier and guarding systems',#3044,$,$); +#3046=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_05','Balustrade and guarding systems',#3045,$,$); +#3047=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_14','Composite barrier systems',#3045,$,$); +#3048=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_15','Composite pedestrian parapet systems',#3045,$,$); +#3049=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_16','Composite post and panel barrier systems',#3045,$,$); +#3050=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_17','Composite post and rail barrier systems',#3045,$,$); +#3051=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_18','Concrete post and rail barrier systems',#3045,$,$); +#3052=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_35','Handrail systems',#3045,$,$); +#3053=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_37','Hoop barrier systems',#3045,$,$); +#3054=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_52','Metal modular barrier systems',#3045,$,$); +#3055=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_53','Metal pedestrian parapet systems',#3045,$,$); +#3056=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_54','Metal post and mesh panel barrier systems',#3045,$,$); +#3057=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_55','Metal post and panel barrier systems',#3045,$,$); +#3058=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_56','Metal post and rail barrier systems',#3045,$,$); +#3059=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_57','Metal vertical bar pedestrian guard rail systems',#3045,$,$); +#3060=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_60','Pedestrian parapet systems',#3045,$,$); +#3061=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_65','Post and panel barrier systems',#3045,$,$); +#3062=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_66','Post and rail barrier systems',#3045,$,$); +#3063=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_67','Post and rope barrier systems',#3045,$,$); +#3064=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_68','Post and wire barrier systems',#3045,$,$); +#3065=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_96','Wood post and panel barrier systems',#3045,$,$); +#3066=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_60_97','Wood post and rail barrier systems',#3045,$,$); +#3067=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_85','Sports barrier systems',#3044,$,$); +#3068=IFCCLASSIFICATIONREFERENCE($,'Ss_25_15_85_55','Multi-use games fencing systems',#3067,$,$); +#3069=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16','Fixed traffic and protective barrier systems',#2933,$,$); +#3070=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_04','Artificial reef systems',#3069,$,$); +#3071=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_05','Avalanche and snow barrier systems',#3069,$,$); +#3072=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_08','Blast barrier systems',#3069,$,$); +#3073=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_08_44','Jet blast deflection systems',#3072,$,$); +#3074=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_21','Debris flow barrier systems',#3069,$,$); +#3075=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_30','Fish barrier systems',#3069,$,$); +#3076=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_46','Landslide barrier systems',#3069,$,$); +#3077=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_50','Coastal, river and waterways protection systems',#3069,$,$); +#3078=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_50_72','Rock armour systems',#3077,$,$); +#3079=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_50_77','Scouring protection systems',#3077,$,$); +#3080=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_50_80','Sea wall systems',#3077,$,$); +#3081=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_73','Road and rail barrier systems',#3069,$,$); +#3082=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_73_03','Acoustic barrier systems',#3081,$,$); +#3083=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_73_05','Anti-throw barrier systems',#3081,$,$); +#3084=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_73_26','Environment protection screen systems',#3081,$,$); +#3085=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_73_80','Socket for temporary barrier systems',#3081,$,$); +#3086=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_76','Rockfall barrier systems',#3069,$,$); +#3087=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_94','Vehicle restraint systems',#3069,$,$); +#3088=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_94_10','Bollard systems',#3087,$,$); +#3089=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_94_14','Combined metal and concrete vehicle safety parapet systems',#3087,$,$); +#3090=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_94_16','Concrete safety barrier (CSB) systems',#3087,$,$); +#3091=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_94_44','Low-speed precast concrete safety parapet (PCONC) systems',#3087,$,$); +#3092=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_94_46','Low-speed masonry safety parapet (PMAS) systems',#3087,$,$); +#3093=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_94_48','Low-speed metal vehicle safety parapet systems',#3087,$,$); +#3094=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_94_50','Metal vehicle safety fence systems',#3087,$,$); +#3095=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_94_65','Protective rail systems',#3087,$,$); +#3096=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_94_95','Vehicle safety control systems',#3087,$,$); +#3097=IFCCLASSIFICATIONREFERENCE($,'Ss_25_16_94_97','Wire rope safety fence (WRSF) systems',#3087,$,$); +#3098=IFCCLASSIFICATIONREFERENCE($,'Ss_25_17','Dam and levee structure systems',#2933,$,$); +#3099=IFCCLASSIFICATIONREFERENCE($,'Ss_25_17_05','Arch dam systems',#3098,$,$); +#3100=IFCCLASSIFICATIONREFERENCE($,'Ss_25_17_10','Buttress dam systems',#3098,$,$); +#3101=IFCCLASSIFICATIONREFERENCE($,'Ss_25_17_25','Embankment dam and levee systems',#3098,$,$); +#3102=IFCCLASSIFICATIONREFERENCE($,'Ss_25_17_35','Gravity dam systems',#3098,$,$); +#3103=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20','Wall cladding systems',#2933,$,$); +#3104=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_08','Board cladding systems',#3103,$,$); +#3105=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_08_95','Weatherboarding systems',#3104,$,$); +#3106=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_14','Composite panel cladding systems',#3103,$,$); +#3107=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_14_10','Built up metal insulating sandwich panel cladding systems',#3106,$,$); +#3108=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_14_52','Metal composite panel cladding systems',#3106,$,$); +#3109=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_14_54','Metal insulating sandwich panel cladding systems',#3106,$,$); +#3110=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_14_55','Metal semi-composite panel cladding systems',#3106,$,$); +#3111=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_15','Concrete cladding systems',#3103,$,$); +#3112=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_15_16','Concrete panel cladding systems',#3111,$,$); +#3113=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_33','Glass fibre reinforced concrete (GRC) cladding systems',#3103,$,$); +#3114=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_33_35','GRC cladding systems',#3113,$,$); +#3115=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_34','Glass fibre reinforced gypsum (GRG) cladding systems',#3103,$,$); +#3116=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_34_35','GRG cladding systems',#3115,$,$); +#3117=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_35','Glass fibre reinforced plastics (GRP) cladding systems',#3103,$,$); +#3118=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_35_35','GRP cladding systems',#3117,$,$); +#3119=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_50','Metal sheet fully supported wall covering systems',#3103,$,$); +#3120=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_50_05','Aluminium sheet cladding systems',#3119,$,$); +#3121=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_50_11','Carbon steel sheet cladding systems',#3119,$,$); +#3122=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_50_15','Copper sheet cladding systems',#3119,$,$); +#3123=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_50_45','Lead sheet cladding systems',#3119,$,$); +#3124=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_50_50','Lead-wrapped panel cladding systems',#3119,$,$); +#3125=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_50_85','Stainless steel sheet cladding systems',#3119,$,$); +#3126=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_50_95','Zinc sheet cladding systems',#3119,$,$); +#3127=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_60','Panel and sheet cladding systems',#3103,$,$); +#3128=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_68','Profiled sheet cladding systems',#3103,$,$); +#3129=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_68_30','Fibre cement profiled sheet cladding systems',#3128,$,$); +#3130=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_68_50','Metal profiled sheet cladding systems',#3128,$,$); +#3131=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_68_65','Plastics profiled sheet cladding systems',#3128,$,$); +#3132=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_70','Rainscreen cladding systems',#3103,$,$); +#3133=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_70_25','Drained and back-ventilated rainscreen cladding systems',#3132,$,$); +#3134=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_70_65','Pressure equalized rainscreen cladding systems',#3132,$,$); +#3135=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_72','Sheet cladding systems',#3103,$,$); +#3136=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_72_72','Rigid sheet cladding systems',#3135,$,$); +#3137=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_85','Stone cladding systems',#3103,$,$); +#3138=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_85_50','Manufactured stone cladding systems',#3137,$,$); +#3139=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_85_55','Natural stone cladding systems',#3137,$,$); +#3140=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_90','Unit cladding systems',#3103,$,$); +#3141=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_90_13','Clay plain tile cladding systems',#3140,$,$); +#3142=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_90_15','Concrete plain tile cladding systems',#3140,$,$); +#3143=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_90_30','Fibre cement slate cladding systems',#3140,$,$); +#3144=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_90_50','Metal tile cladding systems',#3140,$,$); +#3145=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_90_55','Natural slate cladding systems',#3140,$,$); +#3146=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_90_65','Precast concrete cladding systems',#3140,$,$); +#3147=IFCCLASSIFICATIONREFERENCE($,'Ss_25_20_90_95','Wood shingle or shake cladding systems',#3140,$,$); +#3148=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25','Wall lining systems',#2933,$,$); +#3149=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_05','Acoustic panel systems',#3148,$,$); +#3150=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_45','Lining and casing systems',#3148,$,$); +#3151=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_45_25','Duct and wall panel lining systems',#3150,$,$); +#3152=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_45_33','Gypsum board casing systems',#3150,$,$); +#3153=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_45_35','Gypsum board wall lining systems',#3150,$,$); +#3154=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_45_50','Metal framed wall lining systems',#3150,$,$); +#3155=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_45_68','Rigid sheet casing systems',#3150,$,$); +#3156=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_45_70','Rigid sheet wall lining systems',#3150,$,$); +#3157=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_45_88','Timber board casing systems',#3150,$,$); +#3158=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_45_90','Timber board wall lining systems',#3150,$,$); +#3159=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_70','Radiation shielding lining systems',#3148,$,$); +#3160=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_75','Rigid sheet fine lining and panelling systems',#3148,$,$); +#3161=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_75_05','Acoustic panel lining systems',#3160,$,$); +#3162=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_75_30','Framed wood panel lining systems',#3160,$,$); +#3163=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_75_63','Plastics panel lining systems',#3160,$,$); +#3164=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_75_65','Plastics veneered panel lining systems',#3160,$,$); +#3165=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_75_85','Specialist faced panel lining systems',#3160,$,$); +#3166=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_75_95','Wood veneered panel lining systems',#3160,$,$); +#3167=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_85','Stone lining systems',#3148,$,$); +#3168=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_85_50','Manufactured stone lining systems',#3167,$,$); +#3169=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_85_55','Natural stone lining systems',#3167,$,$); +#3170=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_95','Wall sheathing systems',#3148,$,$); +#3171=IFCCLASSIFICATIONREFERENCE($,'Ss_25_25_95_28','External wall sheathing systems',#3170,$,$); +#3172=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30','Door and window systems',#2933,$,$); +#3173=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_15','Concrete wall glazing systems',#3172,$,$); +#3174=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_15_66','Precast concrete security window systems',#3173,$,$); +#3175=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20','Door, shutter and hatch systems',#3172,$,$); +#3176=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_16','Collapsible gate and grille doorset systems',#3175,$,$); +#3177=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_22','Door assembly systems',#3175,$,$); +#3178=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_25','Doorset systems',#3175,$,$); +#3179=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_30','Frame and door leaf systems',#3175,$,$); +#3180=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_32','Frameless glass door systems',#3175,$,$); +#3181=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_35','Hatch systems',#3175,$,$); +#3182=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_37','High security doorset systems',#3175,$,$); +#3183=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_38','High speed doorset systems',#3175,$,$); +#3184=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_39','Hinged doorset systems',#3175,$,$); +#3185=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_40','Industrial doorset systems',#3175,$,$); +#3186=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_45','Loading bay doorset systems',#3175,$,$); +#3187=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_46','Louvre doorset systems',#3175,$,$); +#3188=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_62','Pivot doorset systems',#3175,$,$); +#3189=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_65','Platform door systems',#3175,$,$); +#3190=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_70','Revolving doorset systems',#3175,$,$); +#3191=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_73','Roller grille doorset systems',#3175,$,$); +#3192=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_74','Roller shutter doorset systems',#3175,$,$); +#3193=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_76','Sectional overhead doorset systems',#3175,$,$); +#3194=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_77','Sliding doorset systems',#3175,$,$); +#3195=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_78','Sliding folding doorset systems',#3175,$,$); +#3196=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_80','Sliding stacking panel partition systems',#3175,$,$); +#3197=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_84','Strip curtain doorset systems',#3175,$,$); +#3198=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_20_93','Up and over doorset systems',#3175,$,$); +#3199=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_29','Fire and smoke curtain systems',#3172,$,$); +#3200=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_29_30','Fire curtain systems',#3199,$,$); +#3201=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_29_80','Smoke curtain systems',#3199,$,$); +#3202=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_95','Window systems',#3172,$,$); +#3203=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_95_26','External window systems',#3202,$,$); +#3204=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_95_41','Internal window systems',#3202,$,$); +#3205=IFCCLASSIFICATIONREFERENCE($,'Ss_25_30_95_96','Window walling systems',#3202,$,$); +#3206=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32','Gate and access control systems',#2933,$,$); +#3207=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_35','Gate systems',#3206,$,$); +#3208=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_35_05','Animal gate systems',#3207,$,$); +#3209=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_35_15','Chicane systems',#3207,$,$); +#3210=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_35_30','Folding gate systems',#3207,$,$); +#3211=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_35_37','Hinged gate systems',#3207,$,$); +#3212=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_35_41','In-line inhibitor systems',#3207,$,$); +#3213=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_35_45','Kissing gate systems',#3207,$,$); +#3214=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_35_80','Sliding gate systems',#3207,$,$); +#3215=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_35_85','Stile systems',#3207,$,$); +#3216=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_35_90','Turnstile systems',#3207,$,$); +#3217=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_60','Passport control gate systems',#3206,$,$); +#3218=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_60_26','e-passport gate systems',#3217,$,$); +#3219=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_60_60','Passport gate systems',#3217,$,$); +#3220=IFCCLASSIFICATIONREFERENCE($,'Ss_25_32_70','Railway platform automated barrier systems',#3206,$,$); +#3221=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36','Operable barrier systems',#2933,$,$); +#3222=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_24','Dry dock automated gate systems',#3221,$,$); +#3223=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_30','Flood and storm surge barrier systems',#3221,$,$); +#3224=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_30_30','Flood gate systems',#3223,$,$); +#3225=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_50','Marina and sea gate automated systems',#3221,$,$); +#3226=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_58','Operable rail barrier systems',#3221,$,$); +#3227=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_62','Operable water barrier systems',#3221,$,$); +#3228=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_64','Operable bridge barrier systems',#3221,$,$); +#3229=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_66','Operable tunnel barrier systems',#3221,$,$); +#3230=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_70','Railway crossing systems',#3221,$,$); +#3231=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_95','Vehicle access point control systems',#3221,$,$); +#3232=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_95_05','Automated heavy-duty gate systems',#3231,$,$); +#3233=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_95_35','Heavy duty sliding beam barrier systems',#3231,$,$); +#3234=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_95_36','Height restrictor systems',#3231,$,$); +#3235=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_95_38','Horizontal swing gate systems',#3231,$,$); +#3236=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_95_40','Hydraulic ramp systems',#3231,$,$); +#3237=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_95_50','Movable bollard and car park post systems',#3231,$,$); +#3238=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_95_70','Rising arm barrier systems',#3231,$,$); +#3239=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_95_72','Rising bollard systems',#3231,$,$); +#3240=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_95_85','Static bollard systems',#3231,$,$); +#3241=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_95_94','Vehicle flow plate systems',#3231,$,$); +#3242=IFCCLASSIFICATIONREFERENCE($,'Ss_25_36_95_96','Vehicle stop systems',#3231,$,$); +#3243=IFCCLASSIFICATIONREFERENCE($,'Ss_25_38','Wall and barrier opening hardware systems',#2933,$,$); +#3244=IFCCLASSIFICATIONREFERENCE($,'Ss_25_38_20','Door, window and gate hardware systems',#3243,$,$); +#3245=IFCCLASSIFICATIONREFERENCE($,'Ss_25_38_20_20','Door hardware systems',#3244,$,$); +#3246=IFCCLASSIFICATIONREFERENCE($,'Ss_25_38_20_30','Garage door hardware systems',#3244,$,$); +#3247=IFCCLASSIFICATIONREFERENCE($,'Ss_25_38_20_33','Gate hardware systems',#3244,$,$); +#3248=IFCCLASSIFICATIONREFERENCE($,'Ss_25_38_20_35','Hatch hardware systems',#3244,$,$); +#3249=IFCCLASSIFICATIONREFERENCE($,'Ss_25_38_20_70','Relocatable partition hardware systems',#3244,$,$); +#3250=IFCCLASSIFICATIONREFERENCE($,'Ss_25_38_20_80','Shutter hardware systems',#3244,$,$); +#3251=IFCCLASSIFICATIONREFERENCE($,'Ss_25_38_20_95','Window hardware systems',#3244,$,$); +#3252=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45','Wall covering and finish systems',#2933,$,$); +#3253=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_02','Acoustic covering systems',#3252,$,$); +#3254=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_02_60','Parge coat systems',#3253,$,$); +#3255=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_25','Drapery systems',#3252,$,$); +#3256=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_70','Render and roughcast coating systems',#3252,$,$); +#3257=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_70_55','Multicoat render systems',#3256,$,$); +#3258=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_70_60','One coat render systems',#3256,$,$); +#3259=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_70_90','Tiling and mosaic render substrate systems',#3256,$,$); +#3260=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_72','Rendered insulation systems',#3252,$,$); +#3261=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_72_02','Adhesive fixed external wall insulation systems',#3260,$,$); +#3262=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_72_42','Insulated plinth systems',#3260,$,$); +#3263=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_72_70','Rail fixed external wall insulation systems',#3260,$,$); +#3264=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_74','Rolled paper and fabric covering systems',#3252,$,$); +#3265=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_74_70','Rolled covering systems',#3264,$,$); +#3266=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_85','Sprayed coating systems',#3252,$,$); +#3267=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_85_82','Sprayed external monolithic coating systems',#3266,$,$); +#3268=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_85_85','Sprayed internal monolithic coating systems',#3266,$,$); +#3269=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_86','Suspended render systems',#3252,$,$); +#3270=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_88','Tiling systems',#3252,$,$); +#3271=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_88_25','External wall tiling systems',#3270,$,$); +#3272=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_88_40','Internal wall tiling systems',#3270,$,$); +#3273=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_88_88','Terrazzo wall tiling systems',#3270,$,$); +#3274=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_88_90','Tiling and mosaic mortar substrate systems',#3270,$,$); +#3275=IFCCLASSIFICATIONREFERENCE($,'Ss_25_45_90','Unit facing systems',#3252,$,$); +#3276=IFCCLASSIFICATIONREFERENCE($,'Ss_25_50','Wall mounted canopy and screen systems',#2933,$,$); +#3277=IFCCLASSIFICATIONREFERENCE($,'Ss_25_50_05','Awning systems',#3276,$,$); +#3278=IFCCLASSIFICATIONREFERENCE($,'Ss_25_50_35','Grille systems',#3276,$,$); +#3279=IFCCLASSIFICATIONREFERENCE($,'Ss_25_50_45','Louvre and shading systems',#3276,$,$); +#3280=IFCCLASSIFICATIONREFERENCE($,'Ss_25_50_45_10','Canopy systems',#3279,$,$); +#3281=IFCCLASSIFICATIONREFERENCE($,'Ss_25_50_45_30','Facade-aligned brise soleil systems',#3279,$,$); +#3282=IFCCLASSIFICATIONREFERENCE($,'Ss_25_50_45_45','Louvre screen systems',#3279,$,$); +#3283=IFCCLASSIFICATIONREFERENCE($,'Ss_25_50_45_60','Panellized louvre screen systems',#3279,$,$); +#3284=IFCCLASSIFICATIONREFERENCE($,'Ss_25_50_45_65','Projecting brise soleil systems',#3279,$,$); +#3285=IFCCLASSIFICATIONREFERENCE($,'Ss_25_50_75','Screen systems',#3276,$,$); +#3286=IFCCLASSIFICATIONREFERENCE($,'Ss_25_50_80','Shutter systems',#3276,$,$); +#3287=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60','Wall and barrier accessory systems',#2933,$,$); +#3288=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_10','Cavity wall tie renewal and insertion systems',#3287,$,$); +#3289=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_30','Fire stopping systems',#3287,$,$); +#3290=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_30_40','Individual services penetrations fire stopping systems',#3289,$,$); +#3291=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_30_45','Linear gap fire stopping systems',#3289,$,$); +#3292=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_30_48','Loose fire stopping systems',#3289,$,$); +#3293=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_30_55','Multiple services penetrations fire stopping systems',#3289,$,$); +#3294=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_30_62','Pipe collar fire stopping systems',#3289,$,$); +#3295=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_35','Glazing systems',#3287,$,$); +#3296=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_35_06','Bead-fixed insulating glazing systems',#3295,$,$); +#3297=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_35_08','Bead-fixed single glazing systems',#3295,$,$); +#3298=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_35_30','Fire-resistant glazing systems',#3295,$,$); +#3299=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_35_33','Glazing film systems',#3295,$,$); +#3300=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_35_35','Groove-fixed single glazing systems',#3295,$,$); +#3301=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_35_40','Internal use bead and tape, groove or channel glazing systems',#3295,$,$); +#3302=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_35_50','Mirror glazing systems',#3295,$,$); +#3303=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_35_65','Putty-fronted single glazing systems',#3295,$,$); +#3304=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_35_75','Single-sided gasket glazing systems',#3295,$,$); +#3305=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_35_85','Structural zipper gasket glazing systems',#3295,$,$); +#3306=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_35_95','U-profiled glazing systems',#3295,$,$); +#3307=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50','Metal sheet wall flashing and weathering systems',#3287,$,$); +#3308=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50_03','Aluminium sheet wall flashing systems',#3307,$,$); +#3309=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50_04','Aluminium sheet wall weathering systems',#3307,$,$); +#3310=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50_11','Carbon steel wall flashing systems',#3307,$,$); +#3311=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50_12','Carbon steel wall weathering systems',#3307,$,$); +#3312=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50_14','Copper sheet wall flashing systems',#3307,$,$); +#3313=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50_15','Copper sheet wall weathering systems',#3307,$,$); +#3314=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50_47','Lead damp proof course systems',#3307,$,$); +#3315=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50_48','Lead sheet wall flashing systems',#3307,$,$); +#3316=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50_49','Lead sheet wall weathering systems',#3307,$,$); +#3317=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50_84','Stainless steel sheet wall flashing systems',#3307,$,$); +#3318=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50_85','Stainless steel sheet wall weathering systems',#3307,$,$); +#3319=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50_94','Zinc sheet wall flashing systems',#3307,$,$); +#3320=IFCCLASSIFICATIONREFERENCE($,'Ss_25_60_50_95','Zinc sheet wall weathering systems',#3307,$,$); +#3321=IFCCLASSIFICATIONREFERENCE($,'Ss_25_95','Temporary wall and barrier systems',#2933,$,$); +#3322=IFCCLASSIFICATIONREFERENCE($,'Ss_25_95_30','Temporary flood barrier systems',#3321,$,$); +#3323=IFCCLASSIFICATIONREFERENCE($,'Ss_25_95_60','Temporary pedestrian barrier systems',#3321,$,$); +#3324=IFCCLASSIFICATIONREFERENCE($,'Ss_25_95_70','Temporary rail barrier systems',#3321,$,$); +#3325=IFCCLASSIFICATIONREFERENCE($,'Ss_25_95_75','Temporary road barrier systems',#3321,$,$); +#3326=IFCCLASSIFICATIONREFERENCE($,'Ss_25_95_85','Temporary traffic barrier systems',#3321,$,$); +#3327=IFCCLASSIFICATIONREFERENCE($,'Ss_25_95_90','Temporary water barrier systems',#3321,$,$); +#3328=IFCCLASSIFICATIONREFERENCE($,'Ss_30','Roof, floor and paving systems',#2697,$,$); +#3329=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10','Pitched, arched and domed roof structure systems',#3328,$,$); +#3330=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_30','Framed roof structure systems',#3329,$,$); +#3331=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_30_03','Aluminium roof framing systems',#3330,$,$); +#3332=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_30_20','Glazed unit roof framing systems',#3330,$,$); +#3333=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_30_25','Heavy steel roof framing systems',#3330,$,$); +#3334=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_30_30','Heavy steel roof space frame systems',#3330,$,$); +#3335=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_30_35','Heavy steel roof space truss systems',#3330,$,$); +#3336=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_30_45','Light steel roof framing systems',#3330,$,$); +#3337=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_30_58','Plastics roof framing systems',#3330,$,$); +#3338=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_30_60','Precast concrete roof structure systems',#3330,$,$); +#3339=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_30_70','Reinforced concrete roof framing systems',#3330,$,$); +#3340=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_30_85','Timber roof framing systems',#3330,$,$); +#3341=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_50','Monolithic roof structure systems',#3329,$,$); +#3342=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_50_70','Sprayed concrete roof systems',#3341,$,$); +#3343=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_60','Panel roof structure systems',#3329,$,$); +#3344=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_90','Unit roof structure systems',#3329,$,$); +#3345=IFCCLASSIFICATIONREFERENCE($,'Ss_30_10_90_50','Masonry roof systems',#3344,$,$); +#3346=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12','Flat roof, floor and deck structure systems',#3328,$,$); +#3347=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_05','Beam and block floor systems',#3346,$,$); +#3348=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_15','Concrete plank floor systems',#3346,$,$); +#3349=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_20','Deck systems',#3346,$,$); +#3350=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_30','Flat roof and floor cassette structural insulated panel (SIP) systems',#3346,$,$); +#3351=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_32','Framed decking systems',#3346,$,$); +#3352=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_33','Framed floor systems',#3346,$,$); +#3353=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_34','Framed mezzanine systems',#3346,$,$); +#3354=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_35','Glass unit masonry floor systems',#3346,$,$); +#3355=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_45','Lift-up concrete plank floor systems',#3346,$,$); +#3356=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_50','Masonry (flat arch) floor systems',#3346,$,$); +#3357=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_60','Pier and jetty structure systems',#3346,$,$); +#3358=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_64','Platform systems',#3346,$,$); +#3359=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_64_17','Crosswall platform systems',#3358,$,$); +#3360=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_64_30','Front wall platform systems',#3358,$,$); +#3361=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_64_53','Modular platform systems',#3358,$,$); +#3362=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_85','Structural deck systems',#3346,$,$); +#3363=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_85_15','Composite concrete floor, roof or balcony deck systems',#3362,$,$); +#3364=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_85_16','Composite steel and concrete floor, roof or balcony deck systems',#3362,$,$); +#3365=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_85_17','Concrete beam and block floor or roof deck systems',#3362,$,$); +#3366=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_85_18','Concrete floor or roof deck systems',#3362,$,$); +#3367=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_85_30','Glazed unit floor or roof deck systems',#3362,$,$); +#3368=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_85_40','Heavy steel floor, roof or balcony deck systems',#3362,$,$); +#3369=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_85_50','Light steel floor, roof or balcony deck systems',#3362,$,$); +#3370=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_85_65','Post tensioned concrete floor or roof deck systems',#3362,$,$); +#3371=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_85_70','Reinforced concrete floor, roof or balcony deck systems',#3362,$,$); +#3372=IFCCLASSIFICATIONREFERENCE($,'Ss_30_12_85_90','Timber floor, roof or balcony deck systems',#3362,$,$); +#3373=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14','Paving systems',#3328,$,$); +#3374=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_02','Acrylic and resin bound aggregate paving systems',#3373,$,$); +#3375=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_02_30','Fibre-reinforced resin-bound aggregate overlay systems',#3374,$,$); +#3376=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_02_41','Impact absorbing synthetic play and sport paving systems',#3374,$,$); +#3377=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_02_42','Impervious acrylic coated sports paving systems',#3374,$,$); +#3378=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_02_70','Resin-bonded aggregate paving systems',#3374,$,$); +#3379=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_02_71','Resin-bound aggregate light duty paving systems',#3374,$,$); +#3380=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_02_72','Resin-bound aggregate heavy duty paving systems',#3374,$,$); +#3381=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_02_73','Resin-bound aggregate overlay systems',#3374,$,$); +#3382=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_02_74','Resin-bound stone aggregate sports paving systems',#3374,$,$); +#3383=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_02_85','Synthetic play surfacing systems',#3374,$,$); +#3384=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_05','Asphalt road and paving systems',#3373,$,$); +#3385=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_05_05','Asphalt concrete light duty paving systems',#3384,$,$); +#3386=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_05_06','Asphalt concrete paving systems',#3384,$,$); +#3387=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_05_07','Asphalt concrete runway paving systems',#3384,$,$); +#3388=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_05_08','Asphalt concrete surface overlay systems',#3384,$,$); +#3389=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_05_35','Hot rolled asphalt paving systems',#3384,$,$); +#3390=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_05_36','Hot rolled asphalt runway paving systems',#3384,$,$); +#3391=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_05_40','Hot rolled asphalt sports paving systems',#3384,$,$); +#3392=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_05_50','Mastic asphalt pedestrian paving systems',#3384,$,$); +#3393=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_05_65','Porous asphalt concrete paving systems',#3384,$,$); +#3394=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_05_70','Porous asphalt concrete sports paving systems',#3384,$,$); +#3395=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_05_75','Stone mastic asphalt paving systems',#3384,$,$); +#3396=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_15','Concrete road and paving systems',#3373,$,$); +#3397=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_15_14','Concrete grass-filled paving systems',#3396,$,$); +#3398=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_15_16','Concrete paving systems',#3396,$,$); +#3399=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_15_17','Concrete porous paving systems',#3396,$,$); +#3400=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_15_18','Concrete runway paving systems',#3396,$,$); +#3401=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_50','Mat and sheet paving systems',#3373,$,$); +#3402=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_50_25','Dry ski slope synthetic matting systems',#3401,$,$); +#3403=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_50_65','Polymeric sports paving systems',#3401,$,$); +#3404=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_50_80','Synthetic grass surfacing systems',#3401,$,$); +#3405=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_80','Unbound aggregate paving systems',#3373,$,$); +#3406=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_80_30','Fast dry clay sports paving systems',#3405,$,$); +#3407=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_80_37','Hoggin paving systems',#3405,$,$); +#3408=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_80_40','Hard binding gravel paving systems',#3405,$,$); +#3409=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_80_45','Loose laid aggregate paving systems',#3405,$,$); +#3410=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_80_47','Loose aggregate overlay systems',#3405,$,$); +#3411=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_80_48','Loose gravel paving systems',#3405,$,$); +#3412=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_80_75','Sand play surfacing systems',#3405,$,$); +#3413=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_80_80','Slurry surfacing overlay systems',#3405,$,$); +#3414=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_80_90','Unbound aggregate cycle paving systems',#3405,$,$); +#3415=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_80_95','Woodchip and stone trim trail paving systems',#3405,$,$); +#3416=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_80_98','Woodchip and woodfibre surface paving systems',#3405,$,$); +#3417=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90','Unit paving systems',#3373,$,$); +#3418=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90_11','Cellular plastics grass-filled paving systems',#3417,$,$); +#3419=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90_12','Cellular plastics gravel-filled paving systems',#3417,$,$); +#3420=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90_30','Flag and slab bound paving systems',#3417,$,$); +#3421=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90_32','Flag and slab paving overlay systems',#3417,$,$); +#3422=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90_34','Flag and slab pedestal-supported paving systems',#3417,$,$); +#3423=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90_36','Flag and slab unbound paving systems',#3417,$,$); +#3424=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90_50','Mosaic paving systems',#3417,$,$); +#3425=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90_60','Permeable flag and slab paving systems',#3417,$,$); +#3426=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90_62','Permeable small unit paving systems',#3417,$,$); +#3427=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90_70','Rail track paving systems',#3417,$,$); +#3428=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90_75','Small unit bound paving systems',#3417,$,$); +#3429=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90_80','Small unit paving overlay systems',#3417,$,$); +#3430=IFCCLASSIFICATIONREFERENCE($,'Ss_30_14_90_85','Small unit unbound paving systems',#3417,$,$); +#3431=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16','Static bridge deck structure systems',#3328,$,$); +#3432=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_10','Bridge deck systems',#3431,$,$); +#3433=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_10_08','Box girder bridge deck systems',#3432,$,$); +#3434=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_10_12','Composite steel and concrete bridge deck systems',#3432,$,$); +#3435=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_10_13','Conarch bridge systems',#3432,$,$); +#3436=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_10_15','Concrete half through deck systems',#3432,$,$); +#3437=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_10_16','Concrete slab deck systems',#3432,$,$); +#3438=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_10_30','Filler beam deck systems',#3432,$,$); +#3439=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_10_31','Flat and stepped deck systems',#3432,$,$); +#3440=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_10_53','Modular precast concrete deck systems',#3432,$,$); +#3441=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_10_59','Orthotropic deck systems',#3432,$,$); +#3442=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_10_65','Pre-stressed concrete beam deck systems',#3432,$,$); +#3443=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_10_80','Solid steel slab systems',#3432,$,$); +#3444=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_30','Bridge expansion joint systems',#3431,$,$); +#3445=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_30_04','Asphaltic plug joint systems',#3444,$,$); +#3446=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_30_09','Buried expansion joint systems',#3444,$,$); +#3447=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_30_56','Nosing expansion joint systems with poured sealants',#3444,$,$); +#3448=IFCCLASSIFICATIONREFERENCE($,'Ss_30_16_30_57','Nosing expansion joint systems with preformed compression seals',#3444,$,$); +#3449=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20','Flooring and decking systems',#3328,$,$); +#3450=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_10','Board and rigid sheet floor systems',#3449,$,$); +#3451=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_10_10','Battened timber board floating floor systems',#3450,$,$); +#3452=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_10_15','Battened wood-based rigid sheet floating floor systems',#3450,$,$); +#3453=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_10_45','Joist-supported timber board floor systems',#3450,$,$); +#3454=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_10_50','Joist-supported wood-based rigid sheet floor systems',#3450,$,$); +#3455=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_10_95','Wood-based rigid sheet floating floor systems',#3450,$,$); +#3456=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_15','Construction site',#3449,$,$); +#3457=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_22','Demountable athletics floor systems',#3449,$,$); +#3458=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_30','External deck and boardwalk systems',#3449,$,$); +#3459=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_30_10','Boardwalk systems',#3458,$,$); +#3460=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_30_25','Decking systems',#3458,$,$); +#3461=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_70','Raised floor systems',#3449,$,$); +#3462=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_70_70','Raised access floor systems',#3461,$,$); +#3463=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_90','Wood and composite unit flooring systems',#3449,$,$); +#3464=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_90_15','Composition block flooring systems',#3463,$,$); +#3465=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_90_50','Mosaic parquet panel flooring systems',#3463,$,$); +#3466=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_90_95','Wood block flooring systems',#3463,$,$); +#3467=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_95','Wood strip and board fine flooring systems',#3449,$,$); +#3468=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_95_10','Battened wood floating floor systems',#3467,$,$); +#3469=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_95_15','Composite laminate floating floor systems',#3467,$,$); +#3470=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_95_20','Direct-fixed wood floor systems',#3467,$,$); +#3471=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_95_25','Direct-glued wood floor systems',#3467,$,$); +#3472=IFCCLASSIFICATIONREFERENCE($,'Ss_30_20_95_95','Wood floating floor systems',#3467,$,$); +#3473=IFCCLASSIFICATIONREFERENCE($,'Ss_30_25','Ceiling and soffit systems',#3328,$,$); +#3474=IFCCLASSIFICATIONREFERENCE($,'Ss_30_25_10','Board and sheet ceiling systems',#3473,$,$); +#3475=IFCCLASSIFICATIONREFERENCE($,'Ss_30_25_10_10','Board suspended ceiling systems',#3474,$,$); +#3476=IFCCLASSIFICATIONREFERENCE($,'Ss_30_25_10_26','External ceiling systems',#3474,$,$); +#3477=IFCCLASSIFICATIONREFERENCE($,'Ss_30_25_10_28','External soffit systems',#3474,$,$); +#3478=IFCCLASSIFICATIONREFERENCE($,'Ss_30_25_10_80','Soffit lining and beam casing systems',#3474,$,$); +#3479=IFCCLASSIFICATIONREFERENCE($,'Ss_30_25_22','Demountable suspended ceiling systems',#3473,$,$); +#3480=IFCCLASSIFICATIONREFERENCE($,'Ss_30_25_22_01','Acoustic baffle suspended ceiling systems',#3479,$,$); +#3481=IFCCLASSIFICATIONREFERENCE($,'Ss_30_25_22_30','Fabric membrane ceiling systems',#3479,$,$); +#3482=IFCCLASSIFICATIONREFERENCE($,'Ss_30_25_22_52','Monolithic suspended ceiling systems',#3479,$,$); +#3483=IFCCLASSIFICATIONREFERENCE($,'Ss_30_25_22_70','Raft or island suspended ceiling systems',#3479,$,$); +#3484=IFCCLASSIFICATIONREFERENCE($,'Ss_30_25_22_90','Unit/ modular suspended ceiling systems',#3479,$,$); +#3485=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30','Roof opening systems',#3328,$,$); +#3486=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30_15','Concrete roof glazing systems',#3485,$,$); +#3487=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30_15_42','In situ concrete roof glazing systems',#3486,$,$); +#3488=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30_15_64','Precast concrete lift-out access roof glazing systems',#3486,$,$); +#3489=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30_15_65','Precast concrete roof glazing systems',#3486,$,$); +#3490=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30_34','Glass unit masonry roof light systems',#3485,$,$); +#3491=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30_71','Roof hatch systems',#3485,$,$); +#3492=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30_72','Rooflight and roof window systems',#3485,$,$); +#3493=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30_72_21','Daylight pipe systems',#3492,$,$); +#3494=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30_72_72','Rooflight systems',#3492,$,$); +#3495=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30_72_73','Roof window systems',#3492,$,$); +#3496=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30_73','Roof ventilator systems',#3485,$,$); +#3497=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30_73_60','Passive roof natural ventilator systems',#3496,$,$); +#3498=IFCCLASSIFICATIONREFERENCE($,'Ss_30_30_73_72','Roof smoke ventilator systems',#3496,$,$); +#3499=IFCCLASSIFICATIONREFERENCE($,'Ss_30_32','Floor opening systems',#3328,$,$); +#3500=IFCCLASSIFICATIONREFERENCE($,'Ss_30_32_15','Floor glazing systems',#3499,$,$); +#3501=IFCCLASSIFICATIONREFERENCE($,'Ss_30_32_15_15','Concrete floor glazing systems',#3500,$,$); +#3502=IFCCLASSIFICATIONREFERENCE($,'Ss_30_32_15_64','Precast concrete lift-out access floor glazing systems',#3500,$,$); +#3503=IFCCLASSIFICATIONREFERENCE($,'Ss_30_32_15_65','Precast concrete floor glazing systems',#3500,$,$); +#3504=IFCCLASSIFICATIONREFERENCE($,'Ss_30_32_30','Floor hatch systems',#3499,$,$); +#3505=IFCCLASSIFICATIONREFERENCE($,'Ss_30_34','Pavement opening systems',#3328,$,$); +#3506=IFCCLASSIFICATIONREFERENCE($,'Ss_30_34_03','Animal grid systems',#3505,$,$); +#3507=IFCCLASSIFICATIONREFERENCE($,'Ss_30_34_03_11','Cattle grid systems',#3506,$,$); +#3508=IFCCLASSIFICATIONREFERENCE($,'Ss_30_34_15','Pavement glazing systems',#3505,$,$); +#3509=IFCCLASSIFICATIONREFERENCE($,'Ss_30_34_15_15','Concrete pavement glazing systems',#3508,$,$); +#3510=IFCCLASSIFICATIONREFERENCE($,'Ss_30_34_15_64','Precast concrete lift-out access pavement glazing systems',#3508,$,$); +#3511=IFCCLASSIFICATIONREFERENCE($,'Ss_30_34_15_65','Precast concrete pavement glazing systems',#3508,$,$); +#3512=IFCCLASSIFICATIONREFERENCE($,'Ss_30_34_16','Pavement smoke venting systems',#3505,$,$); +#3513=IFCCLASSIFICATIONREFERENCE($,'Ss_30_34_16_15','Concrete pavement glazing smoke venting systems',#3512,$,$); +#3514=IFCCLASSIFICATIONREFERENCE($,'Ss_30_34_16_16','Concrete pavement non-glazed smoke venting systems',#3512,$,$); +#3515=IFCCLASSIFICATIONREFERENCE($,'Ss_30_34_16_64','Precast concrete pavement glazing smoke venting systems',#3512,$,$); +#3516=IFCCLASSIFICATIONREFERENCE($,'Ss_30_34_16_65','Precast concrete pavement non-glazed smoke venting systems',#3512,$,$); +#3517=IFCCLASSIFICATIONREFERENCE($,'Ss_30_36','Ceiling and soffit opening systems',#3328,$,$); +#3518=IFCCLASSIFICATIONREFERENCE($,'Ss_30_36_10','Ceiling hatch systems',#3517,$,$); +#3519=IFCCLASSIFICATIONREFERENCE($,'Ss_30_36_75','Soffit vent systems',#3517,$,$); +#3520=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40','Roof and balcony covering and finish systems',#3328,$,$); +#3521=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_10','Board roof covering systems',#3520,$,$); +#3522=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_10_30','Flat board roof deck systems',#3521,$,$); +#3523=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_10_60','Pitched board roof sarking systems',#3521,$,$); +#3524=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_30','Flat roof covering systems',#3520,$,$); +#3525=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_30_40','Liquid-applied cold roof covering systems',#3524,$,$); +#3526=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_30_42','Liquid-applied inverted roof covering systems',#3524,$,$); +#3527=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_30_43','Liquid-applied warm roof covering systems',#3524,$,$); +#3528=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_30_50','Mastic asphalt cold roof covering systems',#3524,$,$); +#3529=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_30_52','Mastic asphalt inverted roof covering systems',#3524,$,$); +#3530=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_30_55','Mastic asphalt warm roof covering systems',#3524,$,$); +#3531=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_30_70','Reinforced bitumen membrane cold roof covering systems',#3524,$,$); +#3532=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_30_71','Reinforced bitumen membrane inverted roof covering systems',#3524,$,$); +#3533=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_30_72','Reinforced bitumen membrane warm roof covering systems',#3524,$,$); +#3534=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_30_78','Single layer sheet cold roof covering systems',#3524,$,$); +#3535=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_30_79','Single layer sheet inverted roof covering systems',#3524,$,$); +#3536=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_30_80','Single layer sheet warm roof covering systems',#3524,$,$); +#3537=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_34','Glass roofing systems',#3520,$,$); +#3538=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_34_15','Cantilevered structural glass beam canopy systems',#3537,$,$); +#3539=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_34_60','Point-fixed structural glass canopy systems',#3537,$,$); +#3540=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_34_65','Point-fixed structural glass roof systems',#3537,$,$); +#3541=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_34_70','Point-fixed structural glass soffit systems',#3537,$,$); +#3542=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_34_75','Sloping patent glazing systems',#3537,$,$); +#3543=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50','Metal sheet, fully supported roof and dormer covering systems',#3520,$,$); +#3544=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50_05','Aluminium sheet dormer covering systems',#3543,$,$); +#3545=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50_10','Aluminium sheet roof covering systems',#3543,$,$); +#3546=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50_12','Carbon steel sheet dormer covering systems',#3543,$,$); +#3547=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50_13','Carbon steel sheet roof covering systems',#3543,$,$); +#3548=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50_15','Copper sheet dormer covering systems',#3543,$,$); +#3549=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50_20','Copper sheet roof covering systems',#3543,$,$); +#3550=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50_40','Lead sheet dormer covering systems',#3543,$,$); +#3551=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50_45','Lead sheet roof covering systems',#3543,$,$); +#3552=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50_50','Lead-wrapped panel systems',#3543,$,$); +#3553=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50_75','Stainless steel sheet dormer covering systems',#3543,$,$); +#3554=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50_80','Stainless steel sheet roof covering systems',#3543,$,$); +#3555=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50_90','Zinc sheet dormer covering systems',#3543,$,$); +#3556=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_50_95','Zinc sheet roof covering systems',#3543,$,$); +#3557=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_55','Metal composite panel roof covering systems',#3520,$,$); +#3558=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_55_10','Built up metal insulating sandwich panel roof systems',#3557,$,$); +#3559=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_55_50','Metal composite panel roofing systems',#3557,$,$); +#3560=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_55_54','Metal insulating sandwich panel roof systems',#3557,$,$); +#3561=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_55_55','Metal semi-composite panel roofing systems',#3557,$,$); +#3562=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_65','Profiled sheet roof covering systems',#3520,$,$); +#3563=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_65_30','Fibre cement profiled sheet roof covering systems',#3562,$,$); +#3564=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_65_50','Metal profiled sheet roof covering systems',#3562,$,$); +#3565=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_65_60','Plastics profiled sheet roof covering systems',#3562,$,$); +#3566=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_90','Tensile fabric roofing systems',#3520,$,$); +#3567=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_90_40','Internal single layer tensile fabric roofing systems',#3566,$,$); +#3568=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_90_50','Multilayer tensile fabric roofing systems',#3566,$,$); +#3569=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_90_75','Single layer tensile fabric roofing systems',#3566,$,$); +#3570=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_92','Thatch roof covering systems',#3520,$,$); +#3571=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_92_85','Thatch roofing systems',#3570,$,$); +#3572=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_95','Unit roofing systems',#3520,$,$); +#3573=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_95_10','Bitumen membrane shingle roofing systems',#3572,$,$); +#3574=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_95_15','Ceramic slate roofing systems',#3572,$,$); +#3575=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_95_30','Fibre cement slate roofing systems',#3572,$,$); +#3576=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_95_40','Interlocking tile roofing systems',#3572,$,$); +#3577=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_95_50','Metal tile roofing systems',#3572,$,$); +#3578=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_95_55','Natural slate roofing systems',#3572,$,$); +#3579=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_95_60','Natural stone slate roofing systems',#3572,$,$); +#3580=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_95_65','Plain tile roofing systems',#3572,$,$); +#3581=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_95_70','Reconstituted slate roofing systems',#3572,$,$); +#3582=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_95_74','Roofing edges and junction systems',#3572,$,$); +#3583=IFCCLASSIFICATIONREFERENCE($,'Ss_30_40_95_95','Wood shake or shingle roofing systems',#3572,$,$); +#3584=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42','Floor covering and finishing systems',#3328,$,$); +#3585=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_10','Calcium sulfate-based screed systems',#3584,$,$); +#3586=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_10_10','Bonded calcium sulfate-based screed systems',#3585,$,$); +#3587=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_10_30','Floating calcium sulfate-based screed systems',#3585,$,$); +#3588=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_10_90','Unbonded calcium sulfate-based screed systems',#3585,$,$); +#3589=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_15','Cementitious screed systems',#3584,$,$); +#3590=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_15_10','Bonded or partially bonded cementitious levelling screed systems',#3589,$,$); +#3591=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_15_15','Cementitious wearing screed systems',#3589,$,$); +#3592=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_15_30','Floating cementitious levelling screed systems',#3589,$,$); +#3593=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_15_90','Unbonded cementitious levelling screed systems',#3589,$,$); +#3594=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_20','Deck covering systems',#3584,$,$); +#3595=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_30','Floor paint systems',#3584,$,$); +#3596=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_30_30','Floor coating systems',#3595,$,$); +#3597=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_32','Floor tiling systems',#3584,$,$); +#3598=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_32_30','External floor tiling systems',#3597,$,$); +#3599=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_32_40','Internal floor tiling systems',#3597,$,$); +#3600=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_40','Ice rink floor systems',#3584,$,$); +#3601=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_50','Masonry flooring systems',#3584,$,$); +#3602=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_52','Mastic asphalt flooring and floor underlay systems',#3584,$,$); +#3603=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_52_50','Mastic asphalt flooring systems',#3602,$,$); +#3604=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_52_52','Mastic asphalt floor underlay systems',#3602,$,$); +#3605=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_54','Monolithic flooring systems',#3584,$,$); +#3606=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_54_75','Resin flooring systems',#3605,$,$); +#3607=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_72','Resilient and textile floor covering systems',#3584,$,$); +#3608=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_72_05','Adhesive-fixed rolled carpet systems',#3607,$,$); +#3609=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_72_10','Carpet tile systems',#3607,$,$); +#3610=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_72_25','Edge-fixed carpet systems',#3607,$,$); +#3611=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_72_72','Resilient sheet floor covering systems',#3607,$,$); +#3612=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_72_75','Resilient tile floor covering systems',#3607,$,$); +#3613=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_90','Terrazzo floor tiling and screed systems',#3584,$,$); +#3614=IFCCLASSIFICATIONREFERENCE($,'Ss_30_42_90_90','Terrazzo floor covering systems',#3613,$,$); +#3615=IFCCLASSIFICATIONREFERENCE($,'Ss_30_45','Pavement covering and finishing systems',#3328,$,$); +#3616=IFCCLASSIFICATIONREFERENCE($,'Ss_30_47','Ceiling and soffit covering and finishing systems',#3328,$,$); +#3617=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60','Roof, floor and paving accessory systems',#3328,$,$); +#3618=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_30','Floor feature systems',#3617,$,$); +#3619=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_30_26','Entrance matting systems',#3618,$,$); +#3620=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_50','Metal sheet roof flashing systems',#3617,$,$); +#3621=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_50_03','Aluminium roof flashing systems',#3620,$,$); +#3622=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_50_04','Aluminium roof weathering systems',#3620,$,$); +#3623=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_50_11','Carbon steel roof flashing systems',#3620,$,$); +#3624=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_50_12','Carbon steel roof weathering systems',#3620,$,$); +#3625=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_50_19','Copper roof flashing systems',#3620,$,$); +#3626=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_50_20','Copper roof weathering systems',#3620,$,$); +#3627=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_50_47','Lead roof flashing systems',#3620,$,$); +#3628=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_50_48','Lead roof weathering systems',#3620,$,$); +#3629=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_50_84','Stainless steel roof flashing systems',#3620,$,$); +#3630=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_50_85','Stainless steel roof weathering systems',#3620,$,$); +#3631=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_50_98','Zinc roof flashing systems',#3620,$,$); +#3632=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_50_99','Zinc roof weathering systems',#3620,$,$); +#3633=IFCCLASSIFICATIONREFERENCE($,'Ss_30_60_70','Roof feature systems',#3617,$,$); +#3634=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75','Roof, floor and paving drainage systems',#3328,$,$); +#3635=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_40','Kerb and channel systems',#3634,$,$); +#3636=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_40_30','Footway grating systems',#3635,$,$); +#3637=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_40_50','Multi unit surface drainage channel systems',#3635,$,$); +#3638=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_40_75','Single unit surface drainage channel systems',#3635,$,$); +#3639=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_45','Kerb and traffic separation systems',#3634,$,$); +#3640=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_45_03','Asphalt kerb systems',#3639,$,$); +#3641=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_45_15','Concrete kerb systems',#3639,$,$); +#3642=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_45_20','Demarcation paving systems',#3639,$,$); +#3643=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_45_45','Light duty kerb systems',#3639,$,$); +#3644=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_45_55','Multi unit traffic calming systems',#3639,$,$); +#3645=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_45_65','Precast kerb systems',#3639,$,$); +#3646=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_45_80','Single unit traffic calming systems',#3639,$,$); +#3647=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_45_85','Traffic kerb systems',#3639,$,$); +#3648=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_45_86','Traffic separation systems',#3639,$,$); +#3649=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_50','Metal sheet gutter lining systems',#3634,$,$); +#3650=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_50_05','Aluminium sheet gutter lining systems',#3649,$,$); +#3651=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_50_11','Carbon steel sheet gutter lining systems',#3649,$,$); +#3652=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_50_15','Copper sheet gutter lining systems',#3649,$,$); +#3653=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_50_45','Lead sheet gutter lining systems',#3649,$,$); +#3654=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_50_75','Stainless steel sheet gutter lining systems',#3649,$,$); +#3655=IFCCLASSIFICATIONREFERENCE($,'Ss_30_75_50_95','Zinc sheet gutter lining systems',#3649,$,$); +#3656=IFCCLASSIFICATIONREFERENCE($,'Ss_30_95','Temporary roof, floor and paving systems',#3328,$,$); +#3657=IFCCLASSIFICATIONREFERENCE($,'Ss_32','Damp proofing, waterproofing and plaster finishing systems',#2697,$,$); +#3658=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20','Damp proofing systems',#3657,$,$); +#3659=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_20','Damp proof courses renewal and insertion systems',#3658,$,$); +#3660=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_20_15','Chemical injection damp proof course systems',#3659,$,$); +#3661=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_20_62','Physical insertion horizontal damp proof course systems',#3659,$,$); +#3662=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_20_63','Physical insertion horizontal or stepped cavity tray systems',#3659,$,$); +#3663=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_20_64','Physical insertion proprietary rising damp remedial systems',#3659,$,$); +#3664=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_20_65','Physical insertion vertical damp proof course systems',#3659,$,$); +#3665=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30','Floor damp proofing systems',#3658,$,$); +#3666=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_10','Cementitious mortar slurry floor damp proofing systems',#3665,$,$); +#3667=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_15','Cold-applied liquid floor damp proofing systems',#3665,$,$); +#3668=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_30','Fully-bonded bitumen membrane overslab damp proofing systems',#3665,$,$); +#3669=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_35','Fully-bonded bitumen membrane underslab damp proofing systems',#3665,$,$); +#3670=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_40','Hot-applied liquid floor damp proofing systems',#3665,$,$); +#3671=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_45','Loose-laid bitumen membrane overslab damp proofing systems',#3665,$,$); +#3672=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_46','Loose-laid bitumen membrane underslab damp proofing systems',#3665,$,$); +#3673=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_48','Loose-laid polyethylene membrane oversite damp proofing systems',#3665,$,$); +#3674=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_50','Loose-laid polyethylene membrane overslab damp proofing systems',#3665,$,$); +#3675=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_51','Loose-laid polyethylene membrane underslab damp proofing systems',#3665,$,$); +#3676=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_55','Mastic asphalt floor damp proofing systems',#3665,$,$); +#3677=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_60','Plastics studded membrane floor damp proofing systems',#3665,$,$); +#3678=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_65','Pre-applied anchored membrane underslab damp proofing systems',#3665,$,$); +#3679=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_30_75','Self-adhesive bitumen membrane floor damp proofing systems',#3665,$,$); +#3680=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_95','Wall damp proofing systems',#3658,$,$); +#3681=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_95_10','Cementitious mortar slurry internal wall damp proofing systems',#3680,$,$); +#3682=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_95_15','Cold-applied liquid internal wall damp proofing systems',#3680,$,$); +#3683=IFCCLASSIFICATIONREFERENCE($,'Ss_32_20_95_65','Plastics studded membrane internal wall damp-proofing systems',#3680,$,$); +#3684=IFCCLASSIFICATIONREFERENCE($,'Ss_32_46','Lath and plaster systems',#3657,$,$); +#3685=IFCCLASSIFICATIONREFERENCE($,'Ss_32_46_50','Metal lathing and anchored mesh reinforcement systems',#3684,$,$); +#3686=IFCCLASSIFICATIONREFERENCE($,'Ss_32_46_50_05','Anchored mesh reinforcement systems',#3685,$,$); +#3687=IFCCLASSIFICATIONREFERENCE($,'Ss_32_46_50_50','Metal lathing casing systems',#3685,$,$); +#3688=IFCCLASSIFICATIONREFERENCE($,'Ss_32_46_50_51','Metal lathing on framing systems',#3685,$,$); +#3689=IFCCLASSIFICATIONREFERENCE($,'Ss_32_46_50_52','Metal lathing on hangers, bearers and runners systems',#3685,$,$); +#3690=IFCCLASSIFICATIONREFERENCE($,'Ss_32_46_50_53','Metal lathing on solid substrate systems',#3685,$,$); +#3691=IFCCLASSIFICATIONREFERENCE($,'Ss_32_46_65','Plaster coating systems',#3684,$,$); +#3692=IFCCLASSIFICATIONREFERENCE($,'Ss_32_46_65_15','Clay plaster systems',#3691,$,$); +#3693=IFCCLASSIFICATIONREFERENCE($,'Ss_32_46_65_55','Multicoat plaster systems',#3691,$,$); +#3694=IFCCLASSIFICATIONREFERENCE($,'Ss_32_46_65_58','One coat plaster systems',#3691,$,$); +#3695=IFCCLASSIFICATIONREFERENCE($,'Ss_32_46_65_90','Tiling and mosaic plaster substrate systems',#3691,$,$); +#3696=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80','Waterproofing and tanking systems',#3657,$,$); +#3697=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_03','Applied waterproofing and tanking systems',#3696,$,$); +#3698=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_03_08','Bridge deck liquid sprayed systems',#3697,$,$); +#3699=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_03_10','Cementitious proprietary mortar slurry tanking systems',#3697,$,$); +#3700=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_03_12','Cementitious site-batched-and-mixed mortar tanking systems',#3697,$,$); +#3701=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_03_14','Cold-applied liquid external tanking systems',#3697,$,$); +#3702=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_03_16','Cold-applied liquid sandwiched tanking systems',#3697,$,$); +#3703=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_03_18','Crystallization-active cementitious mortar dry shake tanking systems',#3697,$,$); +#3704=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_03_20','Crystallization-active cementitious mortar slurry tanking systems',#3697,$,$); +#3705=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_03_40','Interstitial grouting systems',#3697,$,$); +#3706=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_03_50','Mastic asphalt external tanking systems',#3697,$,$); +#3707=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_03_52','Mastic asphalt sandwiched tanking systems',#3697,$,$); +#3708=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_03_54','Mastic asphalt tank lining systems',#3697,$,$); +#3709=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_03_90','Tunnel spray-applied membrane systems',#3697,$,$); +#3710=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79','Sheeted waterproofing and tanking systems',#3696,$,$); +#3711=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_08','Bridge deck sheet systems',#3710,$,$); +#3712=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_30','Fully bonded bitumen membrane external tanking systems',#3710,$,$); +#3713=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_32','Fully bonded bitumen membrane sandwiched tanking systems',#3710,$,$); +#3714=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_33','Fully bonded flexible sheet membrane waterproofing systems',#3710,$,$); +#3715=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_35','Ground supported water retention sheet lining systems',#3710,$,$); +#3716=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_36','Hard rigid plastics sheet membrane waterproofing systems',#3710,$,$); +#3717=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_40','High density plastics studded membrane cavity drain waterproofing systems',#3710,$,$); +#3718=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_45','Loose-laid bentonite membrane external or sandwiched tanking systems',#3710,$,$); +#3719=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_75','Self-adhesive bitumen membrane external tanking systems',#3710,$,$); +#3720=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_77','Self-adhesive bitumen membrane sandwiched tanking systems',#3710,$,$); +#3721=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_84','Steel membrane waterproofing systems',#3710,$,$); +#3722=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_85','Structure supported water retention sheet lining systems',#3710,$,$); +#3723=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_90','Tunnel sheet membrane systems',#3710,$,$); +#3724=IFCCLASSIFICATIONREFERENCE($,'Ss_32_80_79_92','Unbonded flexible sheet membrane waterproofing systems',#3710,$,$); +#3725=IFCCLASSIFICATIONREFERENCE($,'Ss_35','Stair and ramp systems',#2697,$,$); +#3726=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10','Stair and ramp structure systems',#3725,$,$); +#3727=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_25','External stair and ramp systems',#3726,$,$); +#3728=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_25_34','Ground bearing external ramp systems',#3727,$,$); +#3729=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_25_35','Ground bearing external stair systems',#3727,$,$); +#3730=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_25_83','Suspended external ramp systems',#3727,$,$); +#3731=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_25_85','Suspended external stair systems',#3727,$,$); +#3732=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_30','Fixed utilitarian access systems',#3726,$,$); +#3733=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_30_15','Companionway ladder systems',#3732,$,$); +#3734=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_30_40','Industrial stair systems',#3732,$,$); +#3735=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_30_60','Permanently-fixed roof ladder systems',#3732,$,$); +#3736=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_30_62','Permanently-fixed vertical ladder systems',#3732,$,$); +#3737=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_30_95','Working platform and walkway systems',#3732,$,$); +#3738=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_40','Internal stair and ramp systems',#3726,$,$); +#3739=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_40_20','Curved internal stair systems',#3738,$,$); +#3740=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_40_40','Internal ramp systems',#3738,$,$); +#3741=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_40_42','Internal stair systems',#3738,$,$); +#3742=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_40_84','Straight internal stair systems',#3738,$,$); +#3743=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_50','Marine and waterside ramp systems',#3726,$,$); +#3744=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_50_29','Fixed ramp systems',#3743,$,$); +#3745=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_50_31','Floating pontoon ramp systems',#3743,$,$); +#3746=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_50_42','Integral pontoon ramp systems',#3743,$,$); +#3747=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_85','Structural stair and ramp systems',#3726,$,$); +#3748=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_85_15','Concrete stair or ramp systems',#3747,$,$); +#3749=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_85_35','Heavy steel stair or ramp systems',#3747,$,$); +#3750=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_85_65','Precast concrete stair or ramp systems',#3747,$,$); +#3751=IFCCLASSIFICATIONREFERENCE($,'Ss_35_10_85_90','Timber stair or ramp systems',#3747,$,$); +#3752=IFCCLASSIFICATIONREFERENCE($,'Ss_35_30','Stair and ramp opening systems',#3725,$,$); +#3753=IFCCLASSIFICATIONREFERENCE($,'Ss_35_30_15','Concrete stair and ramp glazing systems',#3752,$,$); +#3754=IFCCLASSIFICATIONREFERENCE($,'Ss_35_30_15_15','Concrete stair tread glazing systems',#3753,$,$); +#3755=IFCCLASSIFICATIONREFERENCE($,'Ss_35_40','Stair and ramp covering and finishing systems',#3725,$,$); +#3756=IFCCLASSIFICATIONREFERENCE($,'Ss_35_40_82','Stair carpeting systems',#3755,$,$); +#3757=IFCCLASSIFICATIONREFERENCE($,'Ss_35_40_82_05','Adhesive-fixed stair carpeting systems',#3756,$,$); +#3758=IFCCLASSIFICATIONREFERENCE($,'Ss_35_95','Temporary stair and ramp systems',#3725,$,$); +#3759=IFCCLASSIFICATIONREFERENCE($,'Ss_37','Tunnel, shaft, vessel and tower systems',#2697,$,$); +#3760=IFCCLASSIFICATIONREFERENCE($,'Ss_37_14','Chute systems',#3759,$,$); +#3761=IFCCLASSIFICATIONREFERENCE($,'Ss_37_14_10','Bulk material chute systems',#3760,$,$); +#3762=IFCCLASSIFICATIONREFERENCE($,'Ss_37_14_25','Escape chute systems',#3760,$,$); +#3763=IFCCLASSIFICATIONREFERENCE($,'Ss_37_14_70','Refuse and linen chute systems',#3760,$,$); +#3764=IFCCLASSIFICATIONREFERENCE($,'Ss_37_14_70_08','Built-in linen chute systems',#3763,$,$); +#3765=IFCCLASSIFICATIONREFERENCE($,'Ss_37_14_70_10','Built-in refuse chute systems',#3763,$,$); +#3766=IFCCLASSIFICATIONREFERENCE($,'Ss_37_14_70_63','Post-fixed linen chute systems',#3763,$,$); +#3767=IFCCLASSIFICATIONREFERENCE($,'Ss_37_14_70_65','Post-fixed refuse chute systems',#3763,$,$); +#3768=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16','Vessel and trench systems',#3759,$,$); +#3769=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_02','Above ground pool systems',#3768,$,$); +#3770=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_05','Basement water retaining systems',#3768,$,$); +#3771=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_10','Bund systems',#3768,$,$); +#3772=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_10_32','Fuel tank bund systems',#3771,$,$); +#3773=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_50','Metal and plastics water retaining systems',#3768,$,$); +#3774=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_65','Pond and wetland systems',#3768,$,$); +#3775=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_65_40','Informal pond systems',#3774,$,$); +#3776=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_65_70','Raised formal pond systems',#3774,$,$); +#3777=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_65_85','Submerged formal pond systems',#3774,$,$); +#3778=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_65_95','Wetland systems',#3774,$,$); +#3779=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_75','Silo systems',#3768,$,$); +#3780=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_90','Trench, pipeway and pit systems',#3768,$,$); +#3781=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_90_11','Cable protection systems',#3780,$,$); +#3782=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_90_28','External underground service duct systems',#3780,$,$); +#3783=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_90_63','Pit systems',#3780,$,$); +#3784=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_95','Watertight structural systems',#3768,$,$); +#3785=IFCCLASSIFICATIONREFERENCE($,'Ss_37_16_95_78','Sewage treatment vessel systems',#3784,$,$); +#3786=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17','Tower, chimney and mast systems',#3759,$,$); +#3787=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_13','Chimney systems',#3786,$,$); +#3788=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_13_50','Masonry chimney stack systems',#3787,$,$); +#3789=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_13_65','Pollution control systems',#3787,$,$); +#3790=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_35','Gantry systems',#3786,$,$); +#3791=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_35_11','Cantilever gantry systems',#3790,$,$); +#3792=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_35_32','Full span gantry systems',#3790,$,$); +#3793=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_35_50','Mast arm sign gantry systems',#3790,$,$); +#3794=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_35_60','Portal sign gantry systems',#3790,$,$); +#3795=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_35_70','Reefer gantry systems',#3790,$,$); +#3796=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_45','Lattice tower and pylon systems',#3786,$,$); +#3797=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_50','Mast and pole systems',#3786,$,$); +#3798=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_50_54','Multi-function pole systems',#3797,$,$); +#3799=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_50_72','Road mast systems',#3797,$,$); +#3800=IFCCLASSIFICATIONREFERENCE($,'Ss_37_17_90','Tower systems',#3786,$,$); +#3801=IFCCLASSIFICATIONREFERENCE($,'Ss_37_40','Tunnel, shaft, vessel and tower covering and finishing systems',#3759,$,$); +#3802=IFCCLASSIFICATIONREFERENCE($,'Ss_37_40_85','Swimming pool tiling systems',#3801,$,$); +#3803=IFCCLASSIFICATIONREFERENCE($,'Ss_37_40_85_83','Swimming pool floor tiling systems',#3802,$,$); +#3804=IFCCLASSIFICATIONREFERENCE($,'Ss_37_40_85_85','Swimming pool wall tiling systems',#3802,$,$); +#3805=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50','Shaft and tunnel structural systems',#3759,$,$); +#3806=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_80','Shaft structure systems',#3805,$,$); +#3807=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_80_50','Masonry lined shaft systems',#3806,$,$); +#3808=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_80_71','Reinforced concrete shaft structure systems',#3806,$,$); +#3809=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_80_77','Segmental shaft structure systems',#3806,$,$); +#3810=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_80_83','Sprayed concrete shaft lining systems',#3806,$,$); +#3811=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_80_90','Unit lined shaft systems',#3806,$,$); +#3812=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_92','Tunnel structure systems',#3805,$,$); +#3813=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_92_11','Cast concrete tunnel invert systems',#3812,$,$); +#3814=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_92_15','Colliery arch tunnel or adit systems',#3812,$,$); +#3815=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_92_50','Masonry tunnel structure systems',#3812,$,$); +#3816=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_92_64','Primary regulating layer sprayed concrete lining systems',#3812,$,$); +#3817=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_92_66','Primary sprayed concrete lining systems',#3812,$,$); +#3818=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_92_71','Reinforced concrete tunnel structure systems',#3812,$,$); +#3819=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_92_75','Secondary cast concrete lining systems',#3812,$,$); +#3820=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_92_76','Secondary regulating layer sprayed concrete lining systems',#3812,$,$); +#3821=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_92_77','Secondary sprayed concrete lining systems',#3812,$,$); +#3822=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_92_79','Sectional tunnel structure systems',#3812,$,$); +#3823=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_92_83','Sprayed concrete tunnel lining systems',#3812,$,$); +#3824=IFCCLASSIFICATIONREFERENCE($,'Ss_37_50_92_90','Unit lined tunnel systems',#3812,$,$); +#3825=IFCCLASSIFICATIONREFERENCE($,'Ss_37_55','Tunnel and shaft opening systems',#3759,$,$); +#3826=IFCCLASSIFICATIONREFERENCE($,'Ss_37_55_60','Opening frame systems',#3825,$,$); +#3827=IFCCLASSIFICATIONREFERENCE($,'Ss_37_55_60_90','Tunnel opening frame systems',#3826,$,$); +#3828=IFCCLASSIFICATIONREFERENCE($,'Ss_37_60','Tunnel, shaft, vessel and tower accessory systems',#3759,$,$); +#3829=IFCCLASSIFICATIONREFERENCE($,'Ss_37_95','Temporary tunnel, shaft, vessel and tower systems',#3759,$,$); +#3830=IFCCLASSIFICATIONREFERENCE($,'Ss_40','Signage, fittings, furnishings and equipment (FF&E) and general finishing systems',#2697,$,$); +#3831=IFCCLASSIFICATIONREFERENCE($,'Ss_40_05','Modular systems',#3830,$,$); +#3832=IFCCLASSIFICATIONREFERENCE($,'Ss_40_05_80','Sanitary modular systems',#3831,$,$); +#3833=IFCCLASSIFICATIONREFERENCE($,'Ss_40_05_80_10','Bathroom pod systems',#3832,$,$); +#3834=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10','Signage systems',#3830,$,$); +#3835=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_20','Direction signage systems',#3834,$,$); +#3836=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_20_70','Route marker signage systems',#3835,$,$); +#3837=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_20_96','Wayfinding signage systems',#3835,$,$); +#3838=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_25','External signage and interpretation systems',#3834,$,$); +#3839=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_25_25','Electrical external signage systems',#3838,$,$); +#3840=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_25_30','Fixed external signage systems',#3838,$,$); +#3841=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_25_32','Free-standing external architectural signage systems',#3838,$,$); +#3842=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_30','Fire and safety signage systems',#3834,$,$); +#3843=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_30_20','Emergency ''do not enter'' signage systems',#3842,$,$); +#3844=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_30_25','Evacuation and safe condition signage systems',#3842,$,$); +#3845=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_30_27','Evacuation and safety way guidance systems',#3842,$,$); +#3846=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_30_30','Fire signage systems',#3842,$,$); +#3847=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_30_36','Hazard signage systems',#3842,$,$); +#3848=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_30_70','Regulatory signage systems',#3842,$,$); +#3849=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_30_75','Safety signage systems',#3842,$,$); +#3850=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_30_93','Warning signage systems',#3842,$,$); +#3851=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_30_95','Water safety signage systems',#3842,$,$); +#3852=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_35','Identification signage systems',#3834,$,$); +#3853=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_35_10','Building signage systems',#3852,$,$); +#3854=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_35_70','Room signage systems',#3852,$,$); +#3855=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_35_80','Spaces signage systems',#3852,$,$); +#3856=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_40','Internal architectural signage systems',#3834,$,$); +#3857=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_40_25','Electrical internal architectural signage systems',#3856,$,$); +#3858=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_40_30','Fixed internal architectural signage systems',#3856,$,$); +#3859=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_40_32','Free-standing internal architectural signage systems',#3856,$,$); +#3860=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_50','Information signage systems',#3834,$,$); +#3861=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_50_03','Advertising signage systems',#3860,$,$); +#3862=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_50_05','Advisory signage systems',#3860,$,$); +#3863=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_50_22','Descriptive signage systems',#3860,$,$); +#3864=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_50_24','Directory signage systems',#3860,$,$); +#3865=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_50_42','Interpretive signage systems',#3860,$,$); +#3866=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_90','Traffic signage and marking systems',#3834,$,$); +#3867=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_90_03','Air traffic signage systems',#3866,$,$); +#3868=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_90_18','Crossing road marking systems',#3866,$,$); +#3869=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_90_20','Cycle traffic signage systems',#3866,$,$); +#3870=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_90_23','Diagrammatic road marking systems',#3866,$,$); +#3871=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_90_36','Hatched road marking systems',#3866,$,$); +#3872=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_90_50','Marine traffic signage systems',#3866,$,$); +#3873=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_90_70','Rail traffic signage systems',#3866,$,$); +#3874=IFCCLASSIFICATIONREFERENCE($,'Ss_40_10_90_72','Road traffic signage systems',#3866,$,$); +#3875=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15','General fittings, furnishings and equipment (FF&E) systems',#3830,$,$); +#3876=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_25','Catering FF&E systems',#3875,$,$); +#3877=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_25_15','Commercial catering FF&E systems',#3876,$,$); +#3878=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_25_20','Domestic catering FF&E systems',#3876,$,$); +#3879=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_35','General and joinery FF&E systems',#3875,$,$); +#3880=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_35_35','General FF&E systems',#3879,$,$); +#3881=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_35_50','Minor joinery systems',#3879,$,$); +#3882=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_46','Laundry FF&E systems',#3875,$,$); +#3883=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_46_15','Commercial laundry FF&E systems',#3882,$,$); +#3884=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_46_20','Domestic laundry FF&E systems',#3882,$,$); +#3885=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_58','Office equipment systems',#3875,$,$); +#3886=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_58_50','Meeting booth systems',#3885,$,$); +#3887=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75','Sanitary appliance systems',#3875,$,$); +#3888=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_05','Bath systems',#3887,$,$); +#3889=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_10','Bidet systems',#3887,$,$); +#3890=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_20','Disposal unit (slop hopper) systems',#3887,$,$); +#3891=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_25','Drinking fountain systems',#3887,$,$); +#3892=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_35','Health care macerator systems',#3887,$,$); +#3893=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_45','Janitorial unit systems',#3887,$,$); +#3894=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_75','Sanitary accessory systems',#3887,$,$); +#3895=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_76','Sauna package systems',#3887,$,$); +#3896=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_77','Scrub-up trough systems',#3887,$,$); +#3897=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_78','Shower area systems',#3887,$,$); +#3898=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_79','Shower cubicle systems',#3887,$,$); +#3899=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_80','Sink systems',#3887,$,$); +#3900=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_85','Steam bath package systems',#3887,$,$); +#3901=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_92','Urinal systems',#3887,$,$); +#3902=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_94','Wash basin systems',#3887,$,$); +#3903=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_96','Wash fountain systems',#3887,$,$); +#3904=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_75_98','Wash trough systems',#3887,$,$); +#3905=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_77','Sauna FF&E systems',#3875,$,$); +#3906=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_90','Toilet systems',#3875,$,$); +#3907=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_90_05','Accessible WC package systems',#3906,$,$); +#3908=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_90_85','Squatting WC systems',#3906,$,$); +#3909=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_90_95','Waterless toilet systems',#3906,$,$); +#3910=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_90_96','WC and wash basin combination systems',#3906,$,$); +#3911=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_90_97','WC systems',#3906,$,$); +#3912=IFCCLASSIFICATIONREFERENCE($,'Ss_40_15_90_98','WC wash and dry combination systems',#3906,$,$); +#3913=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20','Administrative, commercial and protective service FF&E systems',#3830,$,$); +#3914=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_01','Administrative FF&E systems',#3913,$,$); +#3915=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_01_27','Embassy FF&E systems',#3914,$,$); +#3916=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_01_60','Office FF&E systems',#3914,$,$); +#3917=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_01_71','Reception FF&E systems',#3914,$,$); +#3918=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_15','Commercial FF&E systems',#3913,$,$); +#3919=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_15_71','Retail FF&E systems',#3918,$,$); +#3920=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_15_89','Trading floor FF&E systems',#3918,$,$); +#3921=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_30','External public realm FF&E systems',#3913,$,$); +#3922=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_30_01','Acceptance and dispensing systems',#3921,$,$); +#3923=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_30_20','Cycle parking equipment systems',#3921,$,$); +#3924=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_30_28','External furniture systems',#3921,$,$); +#3925=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_30_30','Fixed bin systems',#3921,$,$); +#3926=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_30_65','Playground equipment systems',#3921,$,$); +#3927=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_65','Protective service FF&E systems',#3913,$,$); +#3928=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_65_22','Detention FF&E systems',#3927,$,$); +#3929=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_65_25','Emergency shelter FF&E systems',#3927,$,$); +#3930=IFCCLASSIFICATIONREFERENCE($,'Ss_40_20_65_46','Law court FF&E systems',#3927,$,$); +#3931=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25','Cultural, educational, scientific and information FF&E systems',#3830,$,$); +#3932=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_20','Cultural FF&E systems',#3931,$,$); +#3933=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_20_02','Aquarium FF&E systems',#3932,$,$); +#3934=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_20_03','Art gallery FF&E systems',#3932,$,$); +#3935=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_20_04','Artwork systems',#3932,$,$); +#3936=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_20_05','Auditorium FF&E systems',#3932,$,$); +#3937=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_20_22','Display FF&E systems',#3932,$,$); +#3938=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_20_28','Exhibition FF&E systems',#3932,$,$); +#3939=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_20_85','Studio FF&E systems',#3932,$,$); +#3940=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_20_90','Theatre FF&E systems',#3932,$,$); +#3941=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_26','Education and information FF&E systems',#3931,$,$); +#3942=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_26_15','Classroom FF&E systems',#3941,$,$); +#3943=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_26_47','Library FF&E systems',#3941,$,$); +#3944=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_32','Funerary FF&E systems',#3931,$,$); +#3945=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_32_12','Cemetery equipment systems',#3944,$,$); +#3946=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_71','Religious FF&E systems',#3931,$,$); +#3947=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_71_11','Cathedral, church and chapel FF&E systems',#3946,$,$); +#3948=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_71_52','Mosque FF&E systems',#3946,$,$); +#3949=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_71_86','Synagogue FF&E systems',#3946,$,$); +#3950=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_71_90','Temple FF&E systems',#3946,$,$); +#3951=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_75','Scientific FF&E systems',#3931,$,$); +#3952=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_75_21','Dark room FF&E systems',#3951,$,$); +#3953=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_75_45','Laboratory FF&E systems',#3951,$,$); +#3954=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_75_58','Observatory FF&E systems',#3951,$,$); +#3955=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_80','Stage FF&E systems',#3931,$,$); +#3956=IFCCLASSIFICATIONREFERENCE($,'Ss_40_25_80_90','Tension wire grid systems',#3955,$,$); +#3957=IFCCLASSIFICATIONREFERENCE($,'Ss_40_30','Industrial and agricultural FF&E systems',#3830,$,$); +#3958=IFCCLASSIFICATIONREFERENCE($,'Ss_40_30_02','Agricultural FF&E systems',#3957,$,$); +#3959=IFCCLASSIFICATIONREFERENCE($,'Ss_40_30_02_37','Horticultural FF&E systems',#3958,$,$); +#3960=IFCCLASSIFICATIONREFERENCE($,'Ss_40_30_02_47','Livestock FF&E systems',#3958,$,$); +#3961=IFCCLASSIFICATIONREFERENCE($,'Ss_40_30_42','Industrial FF&E systems',#3957,$,$); +#3962=IFCCLASSIFICATIONREFERENCE($,'Ss_40_30_42_29','Factory FF&E systems',#3961,$,$); +#3963=IFCCLASSIFICATIONREFERENCE($,'Ss_40_30_42_52','Mine FF&E systems',#3961,$,$); +#3964=IFCCLASSIFICATIONREFERENCE($,'Ss_40_30_42_58','Offshore platform FF&E systems',#3961,$,$); +#3965=IFCCLASSIFICATIONREFERENCE($,'Ss_40_30_42_96','Warehouse FF&E systems',#3961,$,$); +#3966=IFCCLASSIFICATIONREFERENCE($,'Ss_40_30_85','Static permanent access and safety equipment systems',#3957,$,$); +#3967=IFCCLASSIFICATIONREFERENCE($,'Ss_40_30_85_55','Netting systems',#3966,$,$); +#3968=IFCCLASSIFICATIONREFERENCE($,'Ss_40_45','Living space FF&E systems',#3830,$,$); +#3969=IFCCLASSIFICATIONREFERENCE($,'Ss_40_45_37','Hotel living space FF&E systems',#3968,$,$); +#3970=IFCCLASSIFICATIONREFERENCE($,'Ss_40_45_37_28','External FF&E systems',#3969,$,$); +#3971=IFCCLASSIFICATIONREFERENCE($,'Ss_40_45_37_36','Hotel bedroom FF&E systems',#3969,$,$); +#3972=IFCCLASSIFICATIONREFERENCE($,'Ss_40_45_37_38','Hotel dining room FF&E systems',#3969,$,$); +#3973=IFCCLASSIFICATIONREFERENCE($,'Ss_40_45_37_45','Kitchen FF&E systems',#3969,$,$); +#3974=IFCCLASSIFICATIONREFERENCE($,'Ss_40_45_37_47','Lounge FF&E systems',#3969,$,$); +#3975=IFCCLASSIFICATIONREFERENCE($,'Ss_40_45_70','Residential living space FF&E systems',#3968,$,$); +#3976=IFCCLASSIFICATIONREFERENCE($,'Ss_40_45_70_07','Bedroom FF&E systems',#3975,$,$); +#3977=IFCCLASSIFICATIONREFERENCE($,'Ss_40_45_70_22','Dining room FF&E systems',#3975,$,$); +#3978=IFCCLASSIFICATIONREFERENCE($,'Ss_40_45_70_24','Domestic kitchen FF&E systems',#3975,$,$); +#3979=IFCCLASSIFICATIONREFERENCE($,'Ss_40_45_70_33','Garden FF&E systems',#3975,$,$); +#3980=IFCCLASSIFICATIONREFERENCE($,'Ss_40_45_70_47','Living room FF&E systems',#3975,$,$); +#3981=IFCCLASSIFICATIONREFERENCE($,'Ss_40_50','Medical, health and welfare FF&E systems',#3830,$,$); +#3982=IFCCLASSIFICATIONREFERENCE($,'Ss_40_50_50','Medical and health FF&E systems',#3981,$,$); +#3983=IFCCLASSIFICATIONREFERENCE($,'Ss_40_50_50_18','Cr\X2\00E8\X0\che FF&E systems',#3982,$,$); +#3984=IFCCLASSIFICATIONREFERENCE($,'Ss_40_50_50_37','Hospital ward FF&E systems',#3982,$,$); +#3985=IFCCLASSIFICATIONREFERENCE($,'Ss_40_50_50_50','Medical and dental surgery FF&E systems',#3982,$,$); +#3986=IFCCLASSIFICATIONREFERENCE($,'Ss_40_50_50_59','Operating theatre FF&E systems',#3982,$,$); +#3987=IFCCLASSIFICATIONREFERENCE($,'Ss_40_50_96','Welfare FF&E systems',#3981,$,$); +#3988=IFCCLASSIFICATIONREFERENCE($,'Ss_40_50_96_04','Animal welfare FF&E systems',#3987,$,$); +#3989=IFCCLASSIFICATIONREFERENCE($,'Ss_40_50_96_71','Rehabilitation FF&E systems',#3987,$,$); +#3990=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70','Recreational FF&E systems',#3830,$,$); +#3991=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_20','Casino FF&E systems',#3990,$,$); +#3992=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_55','Play FF&E systems',#3990,$,$); +#3993=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_55_10','Climbing equipment systems',#3992,$,$); +#3994=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_55_15','Combination play equipment systems',#3992,$,$); +#3995=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_55_35','Gymnastics and exercising equipment systems',#3992,$,$); +#3996=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_55_70','Rocking equipment systems',#3992,$,$); +#3997=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_55_73','Runway equipment systems',#3992,$,$); +#3998=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_55_75','Sand and water play equipment systems',#3992,$,$); +#3999=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_55_80','Slide equipment systems',#3992,$,$); +#4000=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_55_83','Spinning equipment systems',#3992,$,$); +#4001=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_55_85','Swinging equipment systems',#3992,$,$); +#4002=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_60','Pool FF&E systems',#3990,$,$); +#4003=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_60_15','Competitive swimming pool FF&E systems',#4002,$,$); +#4004=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_60_25','Diving pool FF&E systems',#4002,$,$); +#4005=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_60_45','Leisure swimming pool FF&E systems',#4002,$,$); +#4006=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_60_62','Pool transfer aid equipment systems',#4002,$,$); +#4007=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_65','Public house FF&E systems',#3990,$,$); +#4008=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_70','Restaurant FF&E systems',#3990,$,$); +#4009=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_75','Sports FF&E systems',#3990,$,$); +#4010=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_75_05','Ball court FF&E systems',#4009,$,$); +#4011=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_75_20','Cycle course FF&E systems',#4009,$,$); +#4012=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_75_27','Equestrian equipment systems',#4009,$,$); +#4013=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_75_50','Multi-use games area FF&E systems',#4009,$,$); +#4014=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_75_80','Skate park FF&E systems',#4009,$,$); +#4015=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_75_85','Sports pitch FF&E systems',#4009,$,$); +#4016=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_75_90','Trim trail FF&E systems',#4009,$,$); +#4017=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_80','Stadium FF&E systems',#3990,$,$); +#4018=IFCCLASSIFICATIONREFERENCE($,'Ss_40_70_95','Wildlife, eco site and nature conservation FF&E systems',#3990,$,$); +#4019=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85','Transport FF&E systems',#3830,$,$); +#4020=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_01','Aerospace FF&E systems',#4019,$,$); +#4021=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_01_01','Aircraft fire training simulation systems',#4020,$,$); +#4022=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_11','Cable transport FF&E systems',#4019,$,$); +#4023=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_50','Marine and waterway FF&E systems',#4019,$,$); +#4024=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_50_95','Waterside FF&E systems',#4023,$,$); +#4025=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_70','Rail FF&E systems',#4019,$,$); +#4026=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_70_60','Passenger concourse FF&E systems',#4025,$,$); +#4027=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_72','Road FF&E systems',#4019,$,$); +#4028=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_72_11','Car park equipment systems',#4027,$,$); +#4029=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_72_33','Garage FF&E systems',#4027,$,$); +#4030=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_75','Rolling stock depot systems',#4019,$,$); +#4031=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_75_07','Bogie handling systems',#4030,$,$); +#4032=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_75_15','Controlled emission toilet (CET) systems',#4030,$,$); +#4033=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_75_24','Drop systems',#4030,$,$); +#4034=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_75_65','Press systems',#4030,$,$); +#4035=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_75_70','Rail lifting systems',#4030,$,$); +#4036=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_75_75','Sand feeding systems',#4030,$,$); +#4037=IFCCLASSIFICATIONREFERENCE($,'Ss_40_85_75_97','Wheel lathe systems',#4030,$,$); +#4038=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90','General finishing systems',#3830,$,$); +#4039=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_05','Anodizing systems',#4038,$,$); +#4040=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_05_05','Aluminium anodic coating systems',#4039,$,$); +#4041=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_35','Hot dip galvanizing systems',#4038,$,$); +#4042=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_40','Intumescent systems',#4038,$,$); +#4043=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_40_40','Intumescent casting systems',#4042,$,$); +#4044=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_40_42','Intumescent coating systems',#4042,$,$); +#4045=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_60','Painting and clear finishing systems',#4038,$,$); +#4046=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_60_05','Anti-graffiti coating systems',#4045,$,$); +#4047=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_60_20','Decorative varnish or lacquer systems',#4045,$,$); +#4048=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_60_22','Decorative wood stain or dye systems',#4045,$,$); +#4049=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_60_55','Multi-colour coating systems',#4045,$,$); +#4050=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_60_60','Oil gilding systems',#4045,$,$); +#4051=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_60_65','Plastic texture coating systems',#4045,$,$); +#4052=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_60_80','Solvent-borne paint systems',#4045,$,$); +#4053=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_60_85','Special coating systems',#4045,$,$); +#4054=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_60_94','Water-based anti-corrosion systems',#4045,$,$); +#4055=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_60_95','Waterborne paint systems',#4045,$,$); +#4056=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_65','Powder coating systems',#4038,$,$); +#4057=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_65_05','Powder coating for aluminium systems',#4056,$,$); +#4058=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_65_85','Powder coating for steel systems',#4056,$,$); +#4059=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_75','Services painting systems',#4038,$,$); +#4060=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_95','Wood preservative and fire retardant treatment systems',#4038,$,$); +#4061=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_95_30','Fire retardant treatment systems',#4060,$,$); +#4062=IFCCLASSIFICATIONREFERENCE($,'Ss_40_90_95_65','Preservative treatment systems',#4060,$,$); +#4063=IFCCLASSIFICATIONREFERENCE($,'Ss_40_95','Temporary signage and FF&E systems',#3830,$,$); +#4064=IFCCLASSIFICATIONREFERENCE($,'Ss_45','Flora and fauna systems',#2697,$,$); +#4065=IFCCLASSIFICATIONREFERENCE($,'Ss_45_05','Ecosystems',#4064,$,$); +#4066=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10','Flora and fauna control systems',#4064,$,$); +#4067=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_10','Bird, insect and vermin control systems',#4066,$,$); +#4068=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_10_04','Animal control systems',#4067,$,$); +#4069=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_10_10','Bird control systems',#4067,$,$); +#4070=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_10_14','Chemical termite protection systems',#4067,$,$); +#4071=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_10_40','Insect control systems',#4067,$,$); +#4072=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_10_64','Physical termite protection systems',#4067,$,$); +#4073=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_10_72','Rodent control systems',#4067,$,$); +#4074=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_40','Invasive microbial and invertebrate control systems',#4066,$,$); +#4075=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_40_40','Invertebrate control systems',#4074,$,$); +#4076=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_40_50','Microbial control systems',#4074,$,$); +#4077=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_95','Vegetation control systems',#4066,$,$); +#4078=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_95_50','Moss, algae and lichen control systems',#4077,$,$); +#4079=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_95_72','Rooted plants on hard surfaces control systems',#4077,$,$); +#4080=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_95_80','Selective vegetation control systems',#4077,$,$); +#4081=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_95_81','Self-clinging plants on hard surfaces control systems',#4077,$,$); +#4082=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_95_83','Site vegetation control systems',#4077,$,$); +#4083=IFCCLASSIFICATIONREFERENCE($,'Ss_45_10_95_95','Waterborne vegetation control systems',#4077,$,$); +#4084=IFCCLASSIFICATIONREFERENCE($,'Ss_45_30','Aquatic flora systems',#4064,$,$); +#4085=IFCCLASSIFICATIONREFERENCE($,'Ss_45_30_05','Aquatic and wetland planting systems',#4084,$,$); +#4086=IFCCLASSIFICATIONREFERENCE($,'Ss_45_30_05_05','Aquatic planting systems',#4085,$,$); +#4087=IFCCLASSIFICATIONREFERENCE($,'Ss_45_30_05_50','Marginal planting systems',#4085,$,$); +#4088=IFCCLASSIFICATIONREFERENCE($,'Ss_45_30_05_70','Reedbed planting systems',#4085,$,$); +#4089=IFCCLASSIFICATIONREFERENCE($,'Ss_45_30_40','Hydroponic planting systems',#4084,$,$); +#4090=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35','Ground based flora systems',#4064,$,$); +#4091=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_05','Amenity and ornamental planting systems',#4090,$,$); +#4092=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_05_08','Bed-planted annual, perennial and bulb systems',#4091,$,$); +#4093=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_05_35','Grass-planted bulb and wildflower systems',#4091,$,$); +#4094=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_05_37','Grass-planted small tree and shrub systems',#4091,$,$); +#4095=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_05_42','Long-stem planted small tree and shrub systems',#4091,$,$); +#4096=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_05_62','Pit-planted climber systems',#4091,$,$); +#4097=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_05_64','Pit-planted perennial systems',#4091,$,$); +#4098=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_05_66','Pit-planted large tree systems',#4091,$,$); +#4099=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_05_67','Pit-planted small tree and shrub systems',#4091,$,$); +#4100=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_08','Biodiversity and environmental conservation systems',#4090,$,$); +#4101=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_08_29','Flora species introduction systems',#4100,$,$); +#4102=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_08_30','Flora species protection systems',#4100,$,$); +#4103=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_08_35','Habitat creation systems',#4100,$,$); +#4104=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_08_37','Habitat management and enhancement systems',#4100,$,$); +#4105=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_08_38','Habitat protection systems',#4100,$,$); +#4106=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_30','Forestry, biomass, hedging and roadside planting systems',#4090,$,$); +#4107=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_30_40','Hydraulic seeded tree and shrub systems',#4106,$,$); +#4108=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_30_55','Notch-planted tree and shrub systems',#4106,$,$); +#4109=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_30_62','Pit-planted tree and shrub systems',#4106,$,$); +#4110=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_30_72','Ridge and furrow-planted tree and shrub systems',#4106,$,$); +#4111=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_30_75','Seeded tree and shrub systems',#4106,$,$); +#4112=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_30_90','Trench-planted tree and shrub systems',#4106,$,$); +#4113=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_45','Lawn and meadow planting systems',#4090,$,$); +#4114=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_45_33','Grass and wildflower seeding systems',#4113,$,$); +#4115=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_45_35','Grass seeding systems',#4113,$,$); +#4116=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_45_40','Hydraulic seeding systems',#4113,$,$); +#4117=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_45_62','Plastics paving and turf systems',#4113,$,$); +#4118=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_45_65','Pre-seeded mat systems',#4113,$,$); +#4119=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_45_70','Reinforced grass planting systems',#4113,$,$); +#4120=IFCCLASSIFICATIONREFERENCE($,'Ss_45_35_45_90','Turf planting systems',#4113,$,$); +#4121=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40','Artificially supported flora systems',#4064,$,$); +#4122=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_28','External container planting systems',#4121,$,$); +#4123=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_28_25','External planter systems',#4122,$,$); +#4124=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_28_32','Free standing external container planting systems',#4122,$,$); +#4125=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_28_35','Hanging container planting systems',#4122,$,$); +#4126=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_28_85','External planting systems',#4122,$,$); +#4127=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_40','Internal container planting systems',#4121,$,$); +#4128=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_40_32','Free standing internal container planting systems',#4127,$,$); +#4129=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_40_34','Ground level internal container planting systems',#4127,$,$); +#4130=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_40_41','Internal hanging container planting systems',#4127,$,$); +#4131=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_40_42','Internal planter systems',#4127,$,$); +#4132=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_47','Living roof systems',#4121,$,$); +#4133=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_47_09','Brown roof systems',#4132,$,$); +#4134=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_47_28','Extensive green roof systems',#4132,$,$); +#4135=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_47_40','Intensive green roof systems',#4132,$,$); +#4136=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_47_75','Semi-intensive green roof systems',#4132,$,$); +#4137=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_95','Vertical planting systems',#4121,$,$); +#4138=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_95_08','Biofiltration vertical planting systems',#4137,$,$); +#4139=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_95_52','Membranous vertical planting systems',#4137,$,$); +#4140=IFCCLASSIFICATIONREFERENCE($,'Ss_45_40_95_54','Modular unit vertical planting systems',#4137,$,$); +#4141=IFCCLASSIFICATIONREFERENCE($,'Ss_45_50','Artificial flora systems',#4064,$,$); +#4142=IFCCLASSIFICATIONREFERENCE($,'Ss_45_50_05','Artificial planting systems',#4141,$,$); +#4143=IFCCLASSIFICATIONREFERENCE($,'Ss_45_50_05_40','Internal artificial planting systems',#4142,$,$); +#4144=IFCCLASSIFICATIONREFERENCE($,'Ss_45_60','Avian fauna systems',#4064,$,$); +#4145=IFCCLASSIFICATIONREFERENCE($,'Ss_45_65','Insectile fauna systems',#4064,$,$); +#4146=IFCCLASSIFICATIONREFERENCE($,'Ss_45_70','Mammalian fauna systems',#4064,$,$); +#4147=IFCCLASSIFICATIONREFERENCE($,'Ss_45_70_05','Animal conservation systems',#4146,$,$); +#4148=IFCCLASSIFICATIONREFERENCE($,'Ss_45_70_05_27','Animal road crossing systems',#4147,$,$); +#4149=IFCCLASSIFICATIONREFERENCE($,'Ss_45_70_05_29','Animal species introduction systems',#4147,$,$); +#4150=IFCCLASSIFICATIONREFERENCE($,'Ss_45_70_05_30','Animal species protection systems',#4147,$,$); +#4151=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75','Piscine fauna systems',#4064,$,$); +#4152=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30','Fish, eel and lamprey pass systems',#4151,$,$); +#4153=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30_03','Alaskan A baffle pass systems',#4152,$,$); +#4154=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30_06','Baffle and brush pass systems',#4152,$,$); +#4155=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30_09','Brush furnished baffle pass systems',#4152,$,$); +#4156=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30_13','Chevron bottom baffle pass systems',#4152,$,$); +#4157=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30_21','Deep notch and orifice pool pass systems',#4152,$,$); +#4158=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30_23','Deep notch no orifice pool pass systems',#4152,$,$); +#4159=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30_30','Fish pass systems',#4152,$,$); +#4160=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30_46','Larinier super active baffle pass systems',#4152,$,$); +#4161=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30_63','Plane baffle denil pass systems',#4152,$,$); +#4162=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30_65','Pool and orifice pass systems',#4152,$,$); +#4163=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30_67','Pool and traverse pass systems',#4152,$,$); +#4164=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30_77','Shallow v notch pool pass systems',#4152,$,$); +#4165=IFCCLASSIFICATIONREFERENCE($,'Ss_45_75_30_94','Vertical slot pool pass systems',#4152,$,$); +#4166=IFCCLASSIFICATIONREFERENCE($,'Ss_45_80','Reptilian fauna systems',#4064,$,$); +#4167=IFCCLASSIFICATIONREFERENCE($,'Ss_45_85','Artificial fauna systems',#4064,$,$); +#4168=IFCCLASSIFICATIONREFERENCE($,'Ss_50','Disposal systems',#2697,$,$); +#4169=IFCCLASSIFICATIONREFERENCE($,'Ss_50_10','Gas waste collection and distribution systems',#4168,$,$); +#4170=IFCCLASSIFICATIONREFERENCE($,'Ss_50_10_45','Landfill gas collection and distribution systems',#4169,$,$); +#4171=IFCCLASSIFICATIONREFERENCE($,'Ss_50_10_95','Waste gas collection and distribution systems',#4169,$,$); +#4172=IFCCLASSIFICATIONREFERENCE($,'Ss_50_20','Non-aqueous liquid waste collection and distribution systems',#4168,$,$); +#4173=IFCCLASSIFICATIONREFERENCE($,'Ss_50_20_45','Landfill liquid collection and distribution systems',#4172,$,$); +#4174=IFCCLASSIFICATIONREFERENCE($,'Ss_50_20_90','Waste liquid fuel collection and distribution systems',#4172,$,$); +#4175=IFCCLASSIFICATIONREFERENCE($,'Ss_50_20_95','Waste process liquid collection and distribution systems',#4172,$,$); +#4176=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30','Building and land drainage collection systems',#4168,$,$); +#4177=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_02','Rainwater drainage systems',#4176,$,$); +#4178=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_02_28','External gravity rainwater drainage systems',#4177,$,$); +#4179=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_02_40','Internal gravity rainwater drainage systems',#4177,$,$); +#4180=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_02_65','Pressure-assisted full bore rainwater drainage systems',#4177,$,$); +#4181=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_02_80','Siphonic full bore rainwater drainage systems',#4177,$,$); +#4182=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_04','Above ground waste water drainage systems',#4176,$,$); +#4183=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_04_05','Basement waste water drainage systems',#4182,$,$); +#4184=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_04_15','Commercial catering waste water drainage systems',#4182,$,$); +#4185=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_04_95','Above ground external stack wastewater drainage systems',#4182,$,$); +#4186=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_04_97','Above ground internal stack wastewater drainage systems',#4182,$,$); +#4187=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_06','Below ground inspection systems',#4176,$,$); +#4188=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_06_06','Brick manhole systems',#4187,$,$); +#4189=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_06_08','Brick shallow inspection chamber systems',#4187,$,$); +#4190=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_06_10','Brick shallow silt trap and flow control chamber systems',#4187,$,$); +#4191=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_06_12','Concrete deep manhole systems',#4187,$,$); +#4192=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_06_14','Concrete manhole systems',#4187,$,$); +#4193=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_06_16','Concrete shallow inspection chamber systems',#4187,$,$); +#4194=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_06_18','Concrete silt trap and flow control chamber systems',#4187,$,$); +#4195=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_06_62','Plastics deep non-entry inspection chamber systems',#4187,$,$); +#4196=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_06_64','Plastics distribution and sampling chamber systems',#4187,$,$); +#4197=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_06_66','Plastics shallow inspection chamber systems',#4187,$,$); +#4198=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_08','Below ground gravity drainage systems',#4176,$,$); +#4199=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_08_15','Combined below-ground drainage pipeline systems',#4198,$,$); +#4200=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_08_16','Combined sewer overflow systems',#4198,$,$); +#4201=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_08_30','Foul waste water below-ground drainage pipeline systems',#4198,$,$); +#4202=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_08_85','Surface water below-ground drainage pipeline systems',#4198,$,$); +#4203=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_10','Below ground pumped drainage systems',#4176,$,$); +#4204=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_10_06','Below-ground private packaged pumping station and pressure pipeline drainage systems',#4203,$,$); +#4205=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_45','Land drainage systems',#4176,$,$); +#4206=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_45_08','Blanket drain land drainage systems',#4205,$,$); +#4207=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_45_20','Culvert land drainage systems',#4205,$,$); +#4208=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_45_30','Filter drain land drainage systems',#4205,$,$); +#4209=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_45_32','Fin drain piped land drainage systems',#4205,$,$); +#4210=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_45_53','Mole or subsoiling drain land drainage systems',#4205,$,$); +#4211=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_45_55','Narrow slot fin drain land drainage systems',#4205,$,$); +#4212=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_45_75','Slitting or grooving land drainage systems',#4205,$,$); +#4213=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_45_85','Subsoil drainage pipe drain systems',#4205,$,$); +#4214=IFCCLASSIFICATIONREFERENCE($,'Ss_50_30_45_90','Trenchless drain land drainage systems',#4205,$,$); +#4215=IFCCLASSIFICATIONREFERENCE($,'Ss_50_35','Utility surface and waste water drainage collection systems',#4168,$,$); +#4216=IFCCLASSIFICATIONREFERENCE($,'Ss_50_35_65','Pressure relief drainage systems',#4215,$,$); +#4217=IFCCLASSIFICATIONREFERENCE($,'Ss_50_35_65_08','Blanket drain pressure relief systems',#4216,$,$); +#4218=IFCCLASSIFICATIONREFERENCE($,'Ss_50_35_65_30','Filter drain pressure relief systems',#4216,$,$); +#4219=IFCCLASSIFICATIONREFERENCE($,'Ss_50_35_65_35','Geocomposite sheet fin drain pressure relief systems',#4216,$,$); +#4220=IFCCLASSIFICATIONREFERENCE($,'Ss_50_35_80','Storm water gravity drainage systems',#4215,$,$); +#4221=IFCCLASSIFICATIONREFERENCE($,'Ss_50_35_80_10','Bifurcation storm water overflow systems',#4220,$,$); +#4222=IFCCLASSIFICATIONREFERENCE($,'Ss_50_35_80_72','Rigid attenuation or storage tank for stormwater flood attenuation systems',#4220,$,$); +#4223=IFCCLASSIFICATIONREFERENCE($,'Ss_50_35_82','Surface and waste water gravity drainage systems',#4215,$,$); +#4224=IFCCLASSIFICATIONREFERENCE($,'Ss_50_35_82_41','Inlet drainage systems',#4223,$,$); +#4225=IFCCLASSIFICATIONREFERENCE($,'Ss_50_35_82_59','Outlet drainage systems',#4223,$,$); +#4226=IFCCLASSIFICATIONREFERENCE($,'Ss_50_35_82_73','Road drainage systems',#4223,$,$); +#4227=IFCCLASSIFICATIONREFERENCE($,'Ss_50_35_85','Surface and waste water pumped drainage systems',#4215,$,$); +#4228=IFCCLASSIFICATIONREFERENCE($,'Ss_50_40','Solid waste collection and distribution systems',#4168,$,$); +#4229=IFCCLASSIFICATIONREFERENCE($,'Ss_50_40_95','Waste collection systems',#4228,$,$); +#4230=IFCCLASSIFICATIONREFERENCE($,'Ss_50_40_95_65','Pneumatic waste collection systems',#4229,$,$); +#4231=IFCCLASSIFICATIONREFERENCE($,'Ss_50_50','Gas waste storage, treatment and disposal systems',#4168,$,$); +#4232=IFCCLASSIFICATIONREFERENCE($,'Ss_50_50_45','Landfill gas disposal systems',#4231,$,$); +#4233=IFCCLASSIFICATIONREFERENCE($,'Ss_50_50_95','Waste gas treatment and disposal systems',#4231,$,$); +#4234=IFCCLASSIFICATIONREFERENCE($,'Ss_50_60','Non-aqueous liquid waste storage, treatment and disposal systems',#4168,$,$); +#4235=IFCCLASSIFICATIONREFERENCE($,'Ss_50_60_45','Landfill liquid disposal systems',#4234,$,$); +#4236=IFCCLASSIFICATIONREFERENCE($,'Ss_50_60_90','Waste liquid fuel storage and treatment systems',#4234,$,$); +#4237=IFCCLASSIFICATIONREFERENCE($,'Ss_50_60_95','Waste process liquid storage and treatment systems',#4234,$,$); +#4238=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70','Water waste (drainage) storage, treatment and disposal systems',#4168,$,$); +#4239=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05','Below-ground private drainage disposal systems',#4238,$,$); +#4240=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_20','Below-ground waste water drainage field systems',#4239,$,$); +#4241=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_22','Below-ground drainage packaged grease trap systems',#4239,$,$); +#4242=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_23','Below-ground drainage private packaged septic tank systems',#4239,$,$); +#4243=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_24','Below-ground drainage private packaged sewage treatment systems',#4239,$,$); +#4244=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_25','Below-ground drainage private packaged storage tank systems',#4239,$,$); +#4245=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_79','Below-ground drainage concrete soakaway systems',#4239,$,$); +#4246=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_80','Below-ground drainage granular fill soakaway systems',#4239,$,$); +#4247=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_81','Below-ground drainage modular plastics attenuation or storage tank systems',#4239,$,$); +#4248=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_82','Below-ground drainage modular plastics soakaway systems',#4239,$,$); +#4249=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_83','Below-ground drainage packaged oil and petrol interceptor systems',#4239,$,$); +#4250=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_84','Below-ground drainage packaged silt trap systems',#4239,$,$); +#4251=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_85','Below-ground drainage rigid attenuation or storage tank systems',#4239,$,$); +#4252=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_86','Below-ground drainage wet well systems',#4239,$,$); +#4253=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_05_95','Below-ground drainage outfall systems',#4239,$,$); +#4254=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_24','Drainage disposal systems',#4238,$,$); +#4255=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_24_80','Soakaway borehole systems',#4254,$,$); +#4256=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_60','Private drainage treatment systems',#4238,$,$); +#4257=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_60_70','Radioactive wastewater treatment systems',#4256,$,$); +#4258=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_83','Surface water tank systems',#4238,$,$); +#4259=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85','Sustainable drainage systems (SuDS)',#4238,$,$); +#4260=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_00','SuDS management train systems',#4259,$,$); +#4261=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_06','Below ground surface water storage tank systems',#4259,$,$); +#4262=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_08','Bioretention area systems',#4259,$,$); +#4263=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_15','Conveyance swale systems',#4259,$,$); +#4264=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_21','Detention basin systems',#4259,$,$); +#4265=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_24','Dry swale systems',#4259,$,$); +#4266=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_30','Filter strip systems',#4259,$,$); +#4267=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_31','Filter drain systems',#4259,$,$); +#4268=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_32','Filtration treatment and separation systems',#4259,$,$); +#4269=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_33','Geocellular attenuation tank systems',#4259,$,$); +#4270=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_34','Geocellular soakaway systems',#4259,$,$); +#4271=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_35','Granular fill soakaway systems',#4259,$,$); +#4272=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_41','Infiltration basin systems',#4259,$,$); +#4273=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_42','Infiltration trench systems',#4259,$,$); +#4274=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_58','Open channel conveyance systems',#4259,$,$); +#4275=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_61','Pervious pavement systems',#4259,$,$); +#4276=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_64','Pond systems',#4259,$,$); +#4277=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_66','Precast concrete soakaway systems',#4259,$,$); +#4278=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_70','Rainwater harvesting systems',#4259,$,$); +#4279=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_75','Sand filter bed systems',#4259,$,$); +#4280=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_76','Sand filter bed surface systems',#4259,$,$); +#4281=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_85','Swale systems',#4259,$,$); +#4282=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_96','Water butt systems',#4259,$,$); +#4283=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_97','Wet swale systems',#4259,$,$); +#4284=IFCCLASSIFICATIONREFERENCE($,'Ss_50_70_85_98','Wetland drainage systems',#4259,$,$); +#4285=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75','Wastewater storage, treatment and disposal systems',#4168,$,$); +#4286=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_01','Aeration systems',#4285,$,$); +#4287=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_01_22','Diffused aeration systems',#4286,$,$); +#4288=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_01_44','Jet aeration systems',#4286,$,$); +#4289=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_01_51','Mechanical aeration systems',#4286,$,$); +#4290=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_01_90','Tray cascade aeration systems',#4286,$,$); +#4291=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_20','Decanting systems',#4285,$,$); +#4292=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_20_96','Wastewater decanting systems',#4291,$,$); +#4293=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_21','Desludging and sludge handling systems',#4285,$,$); +#4294=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_21_20','Desludging systems',#4293,$,$); +#4295=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_21_75','Settlement tank gravity desludging systems',#4293,$,$); +#4296=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_21_80','Sludge handling and treatment systems',#4293,$,$); +#4297=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_34','Grit treatment and removal systems',#4285,$,$); +#4298=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_34_16','Crossflow grit removal systems',#4297,$,$); +#4299=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_34_60','Package grit treatment and removal systems',#4297,$,$); +#4300=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_34_94','Vortex grit removal systems',#4297,$,$); +#4301=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_41','Inlet works systems',#4285,$,$); +#4302=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_41_15','Concrete inlet works systems',#4301,$,$); +#4303=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_41_60','Package inlet works systems',#4301,$,$); +#4304=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_41_66','Prefabricated inlet works systems',#4301,$,$); +#4305=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_58','Odour control systems',#4285,$,$); +#4306=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_58_07','Bio-filtration systems',#4305,$,$); +#4307=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_58_08','Bio-scrubber systems',#4305,$,$); +#4308=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_58_11','Catalytic iron filter systems',#4305,$,$); +#4309=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_58_23','Dry installation systems',#4305,$,$); +#4310=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_58_96','Wet scrubber systems',#4305,$,$); +#4311=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_67','Primary sewage treatment and final settlement systems',#4285,$,$); +#4312=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_67_38','Horizontal flow tank systems',#4311,$,$); +#4313=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_67_46','Lamella tank systems',#4311,$,$); +#4314=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_67_70','Radial flow tank systems',#4311,$,$); +#4315=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_75','Scum removal systems',#4285,$,$); +#4316=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_75_96','Wastewater scum removal systems',#4315,$,$); +#4317=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_77','Secondary sewage treatment systems',#4285,$,$); +#4318=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_77_01','Activated sludge aeration tank systems',#4317,$,$); +#4319=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_77_07','Biological filter tank systems',#4317,$,$); +#4320=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_92','Wastewater chemical dosing systems',#4285,$,$); +#4321=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_92_13','Chemical dosing systems',#4320,$,$); +#4322=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_93','Wastewater filtration systems',#4285,$,$); +#4323=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_93_02','Aggregate filtration systems',#4322,$,$); +#4324=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_93_07','Biological percolating filter tiling systems',#4322,$,$); +#4325=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_93_52','Membrane filtration systems',#4322,$,$); +#4326=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_94','Wastewater screenings handling systems',#4285,$,$); +#4327=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_94_16','Combined screenings capture and handling systems',#4326,$,$); +#4328=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_94_56','Non-powered screening systems',#4326,$,$); +#4329=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_94_64','Powered screenings capture and handling systems',#4326,$,$); +#4330=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_95','Wastewater supply systems',#4285,$,$); +#4331=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_95_67','Pumped wastewater supply systems',#4330,$,$); +#4332=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_98','Wastewater tank systems',#4285,$,$); +#4333=IFCCLASSIFICATIONREFERENCE($,'Ss_50_75_98_96','Wastewater tank flushing systems',#4332,$,$); +#4334=IFCCLASSIFICATIONREFERENCE($,'Ss_50_80','Solid waste storage, treatment and disposal systems',#4168,$,$); +#4335=IFCCLASSIFICATIONREFERENCE($,'Ss_50_80_40','Incinerator systems',#4334,$,$); +#4336=IFCCLASSIFICATIONREFERENCE($,'Ss_50_80_80','Solid waste compacting systems',#4334,$,$); +#4337=IFCCLASSIFICATIONREFERENCE($,'Ss_50_80_80_96','Waste compactor systems',#4336,$,$); +#4338=IFCCLASSIFICATIONREFERENCE($,'Ss_50_80_82','Solid waste sorting systems',#4334,$,$); +#4339=IFCCLASSIFICATIONREFERENCE($,'Ss_50_80_96','Weighbridge systems',#4334,$,$); +#4340=IFCCLASSIFICATIONREFERENCE($,'Ss_50_80_96_00','Above ground weighbridge systems',#4339,$,$); +#4341=IFCCLASSIFICATIONREFERENCE($,'Ss_50_80_96_63','Pit weighbridge systems',#4339,$,$); +#4342=IFCCLASSIFICATIONREFERENCE($,'Ss_50_95','Temporary disposal systems',#4168,$,$); +#4343=IFCCLASSIFICATIONREFERENCE($,'Ss_55','Piped supply systems',#2697,$,$); +#4344=IFCCLASSIFICATIONREFERENCE($,'Ss_55_05','Gas extraction, treatment and storage systems',#4343,$,$); +#4345=IFCCLASSIFICATIONREFERENCE($,'Ss_55_05_30','Gas extraction systems',#4344,$,$); +#4346=IFCCLASSIFICATIONREFERENCE($,'Ss_55_05_75','Gas storage tank systems',#4344,$,$); +#4347=IFCCLASSIFICATIONREFERENCE($,'Ss_55_05_85','Gas treatment systems',#4344,$,$); +#4348=IFCCLASSIFICATIONREFERENCE($,'Ss_55_05_95','Gas well systems',#4344,$,$); +#4349=IFCCLASSIFICATIONREFERENCE($,'Ss_55_10','Liquid fuel extraction, treatment and storage systems',#4343,$,$); +#4350=IFCCLASSIFICATIONREFERENCE($,'Ss_55_10_70','Liquid fuel extraction systems',#4349,$,$); +#4351=IFCCLASSIFICATIONREFERENCE($,'Ss_55_10_75','Liquid fuel storage tank systems',#4349,$,$); +#4352=IFCCLASSIFICATIONREFERENCE($,'Ss_55_10_85','Liquid fuel treatment systems',#4349,$,$); +#4353=IFCCLASSIFICATIONREFERENCE($,'Ss_55_10_95','Liquid fuel well systems',#4349,$,$); +#4354=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15','Water extraction, treatment and storage systems',#4343,$,$); +#4355=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_65','Potable water storage tank systems',#4354,$,$); +#4356=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_65_15','Concrete potable water storage systems',#4355,$,$); +#4357=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_65_65','Plastics potable water storage systems',#4355,$,$); +#4358=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_65_72','Reinforced concrete potable water storage systems',#4355,$,$); +#4359=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_65_84','Steel framed potable water storage systems',#4355,$,$); +#4360=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_70','Water reservoir systems',#4354,$,$); +#4361=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_72','Water extraction and monitoring systems',#4354,$,$); +#4362=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_72_20','Water extraction borehole systems',#4361,$,$); +#4363=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_72_50','Water monitoring borehole systems',#4361,$,$); +#4364=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_85','Water treatment and purification systems',#4354,$,$); +#4365=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_85_08','Biological aerated flooded filter systems',#4364,$,$); +#4366=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_85_23','Dissolved air flotation systems',#4364,$,$); +#4367=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_85_46','Lamella plate systems',#4364,$,$); +#4368=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_85_75','Sandfilter systems',#4364,$,$); +#4369=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_85_85','Submerged aerated filter systems',#4364,$,$); +#4370=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_95','Wet well systems',#4354,$,$); +#4371=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_95_64','Piled wet well systems',#4370,$,$); +#4372=IFCCLASSIFICATIONREFERENCE($,'Ss_55_15_95_72','Reinforced concrete wet well systems',#4370,$,$); +#4373=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20','Gas distribution and supply systems',#4343,$,$); +#4374=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_15','Compressed air supply systems',#4373,$,$); +#4375=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_15_42','Industrial compressed air supply systems',#4374,$,$); +#4376=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_15_46','Laboratory compressed air supply systems',#4374,$,$); +#4377=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_15_51','Medical compressed air supply systems',#4374,$,$); +#4378=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_33','Gas distribution network systems',#4373,$,$); +#4379=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_33_56','Natural gas distribution network systems',#4378,$,$); +#4380=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_34','Gas supply systems',#4373,$,$); +#4381=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_34_05','Biogas supply systems',#4380,$,$); +#4382=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_34_46','Liquefied petroleum gas (LPG) supply systems',#4380,$,$); +#4383=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_34_57','Natural gas supply systems',#4380,$,$); +#4384=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_34_95','Welding gas supply systems',#4380,$,$); +#4385=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_40','Inert gas supply systems',#4373,$,$); +#4386=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_45','Laboratory gas supply systems',#4373,$,$); +#4387=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_45_05','Laboratory argon supply systems',#4386,$,$); +#4388=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_45_36','Laboratory helium supply systems',#4386,$,$); +#4389=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_45_39','Laboratory hydrogen supply systems',#4386,$,$); +#4390=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_45_56','Laboratory nitrogen supply systems',#4386,$,$); +#4391=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_45_59','Laboratory oxygen supply systems',#4386,$,$); +#4392=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_51','Medical gas supply systems',#4373,$,$); +#4393=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_51_03','Medical anaesthetic gas scavenging systems',#4392,$,$); +#4394=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_51_27','Medical entonox supply systems',#4392,$,$); +#4395=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_51_36','Medical helium/ oxygen mixture supply systems',#4392,$,$); +#4396=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_51_56','Medical nitrous oxide supply systems',#4392,$,$); +#4397=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_51_57','Medical nitrous oxide/ oxygen mixture supply systems',#4392,$,$); +#4398=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_51_59','Medical oxygen supply systems',#4392,$,$); +#4399=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_60','Process gas systems',#4373,$,$); +#4400=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_60_33','Gas vaporizing systems',#4399,$,$); +#4401=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_85','Specialist and high purity gas supply systems',#4373,$,$); +#4402=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_94','Vacuum supply systems',#4373,$,$); +#4403=IFCCLASSIFICATIONREFERENCE($,'Ss_55_20_94_51','Medical vacuum supply systems',#4402,$,$); +#4404=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30','Fire extinguishing systems',#4343,$,$); +#4405=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_35','Gaseous and foam fire extinguishing systems',#4404,$,$); +#4406=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_35_10','Carbon dioxide fire extinguishing systems',#4405,$,$); +#4407=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_35_31','Foam fire extinguishing systems',#4405,$,$); +#4408=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_35_35','Halocarbon gas total flooding fire extinguishing systems',#4405,$,$); +#4409=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_35_40','Inert gas total flooding fire extinguishing systems',#4405,$,$); +#4410=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_65','Portable fire extinguishing systems',#4404,$,$); +#4411=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_65_30','Fire blanket systems',#4410,$,$); +#4412=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_65_35','Fire bucket systems',#4410,$,$); +#4413=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_65_65','Portable fire extinguisher systems',#4410,$,$); +#4414=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_96','Water firefighting systems',#4404,$,$); +#4415=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_96_24','Dry dropper systems',#4414,$,$); +#4416=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_96_25','Dry riser systems',#4414,$,$); +#4417=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_96_29','Fire hose reel systems',#4414,$,$); +#4418=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_96_30','Fire hydrant systems',#4414,$,$); +#4419=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_96_95','Water cannon firefighting systems',#4414,$,$); +#4420=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_96_97','Wet riser systems',#4414,$,$); +#4421=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_98','Water fire suppression systems',#4404,$,$); +#4422=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_98_21','Deluge systems',#4421,$,$); +#4423=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_98_23','Domestic sprinkler systems',#4421,$,$); +#4424=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_98_70','Residential water mist systems',#4421,$,$); +#4425=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_98_85','Sprinkler systems',#4421,$,$); +#4426=IFCCLASSIFICATIONREFERENCE($,'Ss_55_30_98_96','Water mist systems',#4421,$,$); +#4427=IFCCLASSIFICATIONREFERENCE($,'Ss_55_40','Steam distribution and supply systems',#4343,$,$); +#4428=IFCCLASSIFICATIONREFERENCE($,'Ss_55_40_85','Steam supply and condensate systems',#4427,$,$); +#4429=IFCCLASSIFICATIONREFERENCE($,'Ss_55_40_85_38','Hospital steam supply and condensate systems',#4428,$,$); +#4430=IFCCLASSIFICATIONREFERENCE($,'Ss_55_40_85_41','Industrial steam supply and condensate systems',#4428,$,$); +#4431=IFCCLASSIFICATIONREFERENCE($,'Ss_55_50','Liquid fuel distribution and supply systems',#4343,$,$); +#4432=IFCCLASSIFICATIONREFERENCE($,'Ss_55_50_46','Liquid fuel distribution network systems',#4431,$,$); +#4433=IFCCLASSIFICATIONREFERENCE($,'Ss_55_50_46_58','Oil distribution network systems',#4432,$,$); +#4434=IFCCLASSIFICATIONREFERENCE($,'Ss_55_50_47','Liquid fuel supply systems',#4431,$,$); +#4435=IFCCLASSIFICATIONREFERENCE($,'Ss_55_50_47_10','Biodiesel supply systems',#4434,$,$); +#4436=IFCCLASSIFICATIONREFERENCE($,'Ss_55_50_47_12','Bioethanol supply systems',#4434,$,$); +#4437=IFCCLASSIFICATIONREFERENCE($,'Ss_55_50_47_21','Diesel supply systems',#4434,$,$); +#4438=IFCCLASSIFICATIONREFERENCE($,'Ss_55_50_47_32','Fuel oil supply systems',#4434,$,$); +#4439=IFCCLASSIFICATIONREFERENCE($,'Ss_55_50_47_45','Kerosene/ jet fuel supply systems',#4434,$,$); +#4440=IFCCLASSIFICATIONREFERENCE($,'Ss_55_50_47_46','Liquid biofuel supply systems',#4434,$,$); +#4441=IFCCLASSIFICATIONREFERENCE($,'Ss_55_50_47_61','Petrol supply systems',#4434,$,$); +#4442=IFCCLASSIFICATIONREFERENCE($,'Ss_55_60','Process liquid distribution and supply systems',#4343,$,$); +#4443=IFCCLASSIFICATIONREFERENCE($,'Ss_55_60_45','Liquid acids and bases supply systems',#4442,$,$); +#4444=IFCCLASSIFICATIONREFERENCE($,'Ss_55_60_47','Liquid chemicals supply systems',#4442,$,$); +#4445=IFCCLASSIFICATIONREFERENCE($,'Ss_55_60_50','Liquid polymer supply systems',#4442,$,$); +#4446=IFCCLASSIFICATIONREFERENCE($,'Ss_55_60_55','Lubrication supply systems',#4442,$,$); +#4447=IFCCLASSIFICATIONREFERENCE($,'Ss_55_60_55_70','Rail lubrication supply systems',#4446,$,$); +#4448=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70','Water distribution and supply systems',#4343,$,$); +#4449=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_38','Hot and cold water supply systems',#4448,$,$); +#4450=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_38_15','Cold water supply systems',#4449,$,$); +#4451=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_38_20','Direct hot water storage supply systems',#4449,$,$); +#4452=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_38_40','Incoming water supply systems',#4449,$,$); +#4453=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_38_42','Indirect hot water storage supply systems',#4449,$,$); +#4454=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_38_45','Instantaneous hot water supply systems',#4449,$,$); +#4455=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_38_65','Pumped cold water supply systems',#4449,$,$); +#4456=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_39','Hydroelectric pressure water supply systems',#4448,$,$); +#4457=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_39_10','Buried pressure pipeline systems',#4456,$,$); +#4458=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_42','Irrigation systems',#4448,$,$); +#4459=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_42_20','Drip irrigation systems',#4458,$,$); +#4460=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_42_50','Manual irrigation systems',#4458,$,$); +#4461=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_42_60','Passive irrigation systems',#4458,$,$); +#4462=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_42_85','Sprinkler irrigation systems',#4458,$,$); +#4463=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_42_87','Sub-irrigation systems',#4458,$,$); +#4464=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_94','Washing systems',#4448,$,$); +#4465=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_94_94','Wash plant systems',#4464,$,$); +#4466=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_94_96','Wheel washing systems',#4464,$,$); +#4467=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_95','Water distribution network systems',#4448,$,$); +#4468=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_95_50','Mains water distribution network systems',#4467,$,$); +#4469=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_95_66','Private water distribution network systems',#4467,$,$); +#4470=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_96','Water feature systems',#4448,$,$); +#4471=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_96_15','Cascade and waterfall systems',#4470,$,$); +#4472=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_96_31','Fountain and jet systems',#4470,$,$); +#4473=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_96_83','Self-contained water feature systems',#4470,$,$); +#4474=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_96_96','Water play systems',#4470,$,$); +#4475=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_97','Water reclamation systems',#4448,$,$); +#4476=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_97_35','Grey water reclamation systems',#4475,$,$); +#4477=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_97_70','Rainwater reclamation systems',#4475,$,$); +#4478=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_98','Water treatment systems',#4448,$,$); +#4479=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_98_08','Bore water treatment systems',#4478,$,$); +#4480=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_98_85','Swimming pool water treatment systems',#4478,$,$); +#4481=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_98_92','Ultrapure water treatment systems',#4478,$,$); +#4482=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_99','Water management systems',#4448,$,$); +#4483=IFCCLASSIFICATIONREFERENCE($,'Ss_55_70_99_84','Stoplog systems',#4482,$,$); +#4484=IFCCLASSIFICATIONREFERENCE($,'Ss_55_90','Piped solids distribution and supply systems',#4343,$,$); +#4485=IFCCLASSIFICATIONREFERENCE($,'Ss_55_90_65','Piped granule and powder supply systems',#4484,$,$); +#4486=IFCCLASSIFICATIONREFERENCE($,'Ss_55_95','Temporary piped supply systems',#4343,$,$); +#4487=IFCCLASSIFICATIONREFERENCE($,'Ss_60','Heating, cooling and refrigeration systems',#2697,$,$); +#4488=IFCCLASSIFICATIONREFERENCE($,'Ss_60_30','Rail and paving heating systems',#4487,$,$); +#4489=IFCCLASSIFICATIONREFERENCE($,'Ss_60_30_60','Pavement heating systems',#4488,$,$); +#4490=IFCCLASSIFICATIONREFERENCE($,'Ss_60_30_60_27','Electric pavement heating systems',#4489,$,$); +#4491=IFCCLASSIFICATIONREFERENCE($,'Ss_60_30_70','Railway heating systems',#4488,$,$); +#4492=IFCCLASSIFICATIONREFERENCE($,'Ss_60_30_70_65','Points heating systems',#4491,$,$); +#4493=IFCCLASSIFICATIONREFERENCE($,'Ss_60_30_75','Runway heating systems',#4488,$,$); +#4494=IFCCLASSIFICATIONREFERENCE($,'Ss_60_30_90','Tramway heating systems',#4488,$,$); +#4495=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40','Space heating and cooling systems',#4487,$,$); +#4496=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_13','Climatic ceiling and beam systems',#4495,$,$); +#4497=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_13_13','Climatic beam systems',#4496,$,$); +#4498=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_13_14','Climatic ceiling systems',#4496,$,$); +#4499=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_15','Combined heating, cooling and power systems',#4495,$,$); +#4500=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_15_40','Combined heat and power systems',#4499,$,$); +#4501=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_15_90','Combined underfloor heating and cooling systems',#4499,$,$); +#4502=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_17','Cooling systems',#4495,$,$); +#4503=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_17_12','Chilled water systems',#4502,$,$); +#4504=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_17_21','District cooling systems',#4502,$,$); +#4505=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_17_71','Refrigerant cooling systems',#4502,$,$); +#4506=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_17_92','Underfloor chilled water systems',#4502,$,$); +#4507=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_17_94','Variable refrigerant flow systems',#4502,$,$); +#4508=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_17_96','Water cooling systems',#4502,$,$); +#4509=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_36','Heat pump systems',#4495,$,$); +#4510=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_36_05','Air source heat pump systems',#4509,$,$); +#4511=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_36_35','Ground source heat pump systems',#4509,$,$); +#4512=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_36_96','Water source heat pump systems',#4509,$,$); +#4513=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_37','Heating systems',#4495,$,$); +#4514=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_37_21','Direct gas fired heating systems',#4513,$,$); +#4515=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_37_22','District heating systems',#4513,$,$); +#4516=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_37_26','Electric heating systems',#4513,$,$); +#4517=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_37_27','Electric underfloor heating systems',#4513,$,$); +#4518=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_37_28','Electrical resistance trace heating systems',#4513,$,$); +#4519=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_37_48','Low temperature hot water heating systems',#4513,$,$); +#4520=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_37_51','Medium temperature hot water heating systems',#4513,$,$); +#4521=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_37_81','Solar heating systems',#4513,$,$); +#4522=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_37_85','Steam heating systems',#4513,$,$); +#4523=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_37_94','Underfloor low temperature hot water heating systems',#4513,$,$); +#4524=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_84','Space heating and cooling distribution network systems',#4495,$,$); +#4525=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_84_21','District cooling distribution network systems',#4524,$,$); +#4526=IFCCLASSIFICATIONREFERENCE($,'Ss_60_40_84_22','District heating distribution network systems',#4524,$,$); +#4527=IFCCLASSIFICATIONREFERENCE($,'Ss_60_60','Refrigeration systems',#4487,$,$); +#4528=IFCCLASSIFICATIONREFERENCE($,'Ss_60_60_15','Cold room systems',#4527,$,$); +#4529=IFCCLASSIFICATIONREFERENCE($,'Ss_60_60_15_10','Catering cold room systems',#4528,$,$); +#4530=IFCCLASSIFICATIONREFERENCE($,'Ss_60_60_15_50','Mortuary cold room systems',#4528,$,$); +#4531=IFCCLASSIFICATIONREFERENCE($,'Ss_60_60_17','Cold storage systems',#4527,$,$); +#4532=IFCCLASSIFICATIONREFERENCE($,'Ss_60_60_70','Refrigerant systems',#4527,$,$); +#4533=IFCCLASSIFICATIONREFERENCE($,'Ss_60_60_70_15','Refrigerant charging systems',#4532,$,$); +#4534=IFCCLASSIFICATIONREFERENCE($,'Ss_60_60_70_70','Refrigerant recovery systems',#4532,$,$); +#4535=IFCCLASSIFICATIONREFERENCE($,'Ss_60_80','Drying systems',#4487,$,$); +#4536=IFCCLASSIFICATIONREFERENCE($,'Ss_60_80_08','Bottle and can drying systems',#4535,$,$); +#4537=IFCCLASSIFICATIONREFERENCE($,'Ss_60_95','Temporary heating, cooling and refrigeration systems',#4487,$,$); +#4538=IFCCLASSIFICATIONREFERENCE($,'Ss_65','Ventilation and air conditioning systems',#2697,$,$); +#4539=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40','Ventilation systems',#4538,$,$); +#4540=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_25','Dust extract systems',#4539,$,$); +#4541=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_32','Fume extract systems',#4539,$,$); +#4542=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_32_32','Fume cupboard extract systems',#4541,$,$); +#4543=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_32_70','Recirculatory fume cupboard systems',#4541,$,$); +#4544=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_32_75','Safety cabinet extract systems',#4541,$,$); +#4545=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_33','General space ventilation systems',#4539,$,$); +#4546=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_33_45','Kitchen extract ventilation systems',#4545,$,$); +#4547=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_33_48','Local extract ventilation systems',#4545,$,$); +#4548=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_33_50','Mechanical extract ventilation systems',#4545,$,$); +#4549=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_33_51','Mechanical supply ventilation systems',#4545,$,$); +#4550=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_33_52','Mechanical and whole building ventilation systems',#4545,$,$); +#4551=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_33_56','Natural ventilation systems',#4545,$,$); +#4552=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_33_60','Passive stack ventilation systems',#4545,$,$); +#4553=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_33_90','Toilet extract ventilation systems',#4545,$,$); +#4554=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_42','Industrial fume extract systems',#4539,$,$); +#4555=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_42_45','Local exhaust ventilation systems',#4554,$,$); +#4556=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_42_95','Vehicle exhaust extract systems',#4554,$,$); +#4557=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_55','Nuclear ventilation systems',#4539,$,$); +#4558=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_55_22','Decontamination areas ventilation systems',#4557,$,$); +#4559=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_80','Smoke extract and control systems',#4539,$,$); +#4560=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_80_65','Pressure differential systems',#4559,$,$); +#4561=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_80_80','Smoke and heat exhaust ventilation systems',#4559,$,$); +#4562=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_94','Vehicular space ventilation systems',#4539,$,$); +#4563=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_94_10','Car park extract systems',#4562,$,$); +#4564=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_94_11','Car park supply systems',#4562,$,$); +#4565=IFCCLASSIFICATIONREFERENCE($,'Ss_65_40_94_90','Tunnel ventilation systems',#4562,$,$); +#4566=IFCCLASSIFICATIONREFERENCE($,'Ss_65_60','Specialist ventilation systems',#4538,$,$); +#4567=IFCCLASSIFICATIONREFERENCE($,'Ss_65_60_95','Wind tunnel systems',#4566,$,$); +#4568=IFCCLASSIFICATIONREFERENCE($,'Ss_65_80','Air conditioning systems',#4538,$,$); +#4569=IFCCLASSIFICATIONREFERENCE($,'Ss_65_80_05','Central air conditioning systems',#4568,$,$); +#4570=IFCCLASSIFICATIONREFERENCE($,'Ss_65_80_05_10','Centralized all-air conditioning systems',#4569,$,$); +#4571=IFCCLASSIFICATIONREFERENCE($,'Ss_65_80_05_30','Fan coil unit air conditioning systems',#4569,$,$); +#4572=IFCCLASSIFICATIONREFERENCE($,'Ss_65_80_05_40','Induction unit air conditioning systems',#4569,$,$); +#4573=IFCCLASSIFICATIONREFERENCE($,'Ss_65_80_15','Controlled environment systems',#4568,$,$); +#4574=IFCCLASSIFICATIONREFERENCE($,'Ss_65_80_45','Local air conditioning systems',#4568,$,$); +#4575=IFCCLASSIFICATIONREFERENCE($,'Ss_65_80_45_25','Evaporative cooling systems',#4574,$,$); +#4576=IFCCLASSIFICATIONREFERENCE($,'Ss_65_80_45_48','Local underfloor air conditioning systems',#4574,$,$); +#4577=IFCCLASSIFICATIONREFERENCE($,'Ss_65_80_45_72','Room air conditioning systems',#4574,$,$); +#4578=IFCCLASSIFICATIONREFERENCE($,'Ss_65_95','Temporary ventilation and air conditioning systems',#4538,$,$); +#4579=IFCCLASSIFICATIONREFERENCE($,'Ss_70','Electrical systems',#2697,$,$); +#4580=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10','Electrical power generation and transmission systems',#4579,$,$); +#4581=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_30','Fossil fuel power generation systems',#4580,$,$); +#4582=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_30_33','Gas power generating systems',#4581,$,$); +#4583=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_30_70','Reciprocating internal combustion engine',#4581,$,$); +#4584=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_30_72','Reciprocating internal combustion engine driven alternating current generator systems',#4581,$,$); +#4585=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_35','High voltage transmission systems',#4580,$,$); +#4586=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_70','Renewable power generation systems',#4580,$,$); +#4587=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_70_33','Geothermal power generation systems',#4586,$,$); +#4588=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_70_35','Grid-connected photovoltaic systems',#4586,$,$); +#4589=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_70_36','Hydroelectric power generation systems',#4586,$,$); +#4590=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_70_80','Small-scale wave and tidal power generation systems',#4586,$,$); +#4591=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_70_82','Small-scale wind power generation systems',#4586,$,$); +#4592=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_70_85','Stand-alone photovoltaic systems',#4586,$,$); +#4593=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_70_95','Water mill systems',#4586,$,$); +#4594=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_70_97','Water turbine systems',#4586,$,$); +#4595=IFCCLASSIFICATIONREFERENCE($,'Ss_70_10_70_98','Wind power generating systems',#4586,$,$); +#4596=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30','Electricity distribution systems',#4579,$,$); +#4597=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_25','Protection systems',#4596,$,$); +#4598=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_25_25','Earthing and bonding systems',#4597,$,$); +#4599=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_35','High voltage systems',#4596,$,$); +#4600=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_35_30','High voltage site connection systems',#4599,$,$); +#4601=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_35_35','High voltage distribution systems',#4599,$,$); +#4602=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_45','Low voltage systems',#4596,$,$); +#4603=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_45_40','Low voltage site connection systems',#4602,$,$); +#4604=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_45_45','Low voltage distribution systems',#4602,$,$); +#4605=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_45_92','Uninterruptible power supply systems',#4602,$,$); +#4606=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_60','Overhead line traction power distribution systems',#4596,$,$); +#4607=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_60_11','Catenary overhead line systems',#4606,$,$); +#4608=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_60_89','Trolley wire overhead line systems',#4606,$,$); +#4609=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_80','Small power systems',#4596,$,$); +#4610=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_80_35','Hard-wired voltage small power systems',#4609,$,$); +#4611=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_80_45','Low voltage small power systems with prefabricated wiring',#4609,$,$); +#4612=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_90','Conductor rail traction power distribution systems',#4596,$,$); +#4613=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_90_15','Conductor rail electrification systems',#4612,$,$); +#4614=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_90_90','Third rail electrification systems',#4612,$,$); +#4615=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_94','Vehicle charging systems',#4596,$,$); +#4616=IFCCLASSIFICATIONREFERENCE($,'Ss_70_30_94_27','Electric vehicle charging systems',#4615,$,$); +#4617=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80','Lighting systems',#4579,$,$); +#4618=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_01','Aeronautical lighting systems',#4617,$,$); +#4619=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_01_02','Approach lighting systems',#4618,$,$); +#4620=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_01_03','Apron lighting systems',#4618,$,$); +#4621=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_01_47','Lighting beacon systems',#4618,$,$); +#4622=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_01_65','Precision approach path indicator systems',#4618,$,$); +#4623=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_01_74','Runway lighting systems',#4618,$,$); +#4624=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_01_87','Taxiway lighting systems',#4618,$,$); +#4625=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_25','External lighting systems',#4617,$,$); +#4626=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_25_05','Amenity lighting systems',#4625,$,$); +#4627=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_25_70','Roadway lighting systems',#4625,$,$); +#4628=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_25_90','Tunnel lighting systems',#4625,$,$); +#4629=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_33','General space lighting systems',#4617,$,$); +#4630=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_33_12','Central battery supplied emergency lighting systems',#4629,$,$); +#4631=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_33_30','Fibre optic lighting systems',#4629,$,$); +#4632=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_33_33','General lighting systems with prefabricated wiring',#4629,$,$); +#4633=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_33_35','Hard-wired general lighting systems',#4629,$,$); +#4634=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_33_88','Theatrical/ stage lighting systems',#4629,$,$); +#4635=IFCCLASSIFICATIONREFERENCE($,'Ss_70_80_33_92','Underwater lighting systems',#4629,$,$); +#4636=IFCCLASSIFICATIONREFERENCE($,'Ss_70_95','Temporary electrical systems',#4579,$,$); +#4637=IFCCLASSIFICATIONREFERENCE($,'Ss_75','Communications, security, safety, control and protection systems',#2697,$,$); +#4638=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10','Communications systems',#4637,$,$); +#4639=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_21','Data distribution and telecommunications systems',#4638,$,$); +#4640=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_21_21','Data distribution systems',#4639,$,$); +#4641=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_21_48','Local area network (LAN) systems',#4639,$,$); +#4642=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_21_52','Mobile telecommunications systems',#4639,$,$); +#4643=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_21_88','Telecommunications systems',#4639,$,$); +#4644=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_21_97','Wide area network (WAN) systems',#4639,$,$); +#4645=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_46','Listening systems',#4638,$,$); +#4646=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_46_05','Audio-frequency induction-loop systems',#4645,$,$); +#4647=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_46_42','Infrared listening systems',#4645,$,$); +#4648=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_68','Public communications systems',#4638,$,$); +#4649=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_68_02','Advertising display systems',#4648,$,$); +#4650=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_68_07','Bell communication systems',#4648,$,$); +#4651=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_68_13','Clock systems',#4648,$,$); +#4652=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_68_42','Information display systems',#4648,$,$); +#4653=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_68_68','Public address systems',#4648,$,$); +#4654=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_68_69','Queue management systems',#4648,$,$); +#4655=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_70','Radio and television distribution systems',#4638,$,$); +#4656=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_70_70','Radio distribution systems',#4655,$,$); +#4657=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_70_88','Television distribution systems',#4655,$,$); +#4658=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_72','Emergency communication systems',#4638,$,$); +#4659=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_72_30','Firefighting intercom systems',#4658,$,$); +#4660=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_72_70','Radio communications systems',#4658,$,$); +#4661=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_72_72','Roadway emergency communication systems',#4658,$,$); +#4662=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_88','Timing and scoring systems',#4638,$,$); +#4663=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_88_05','Athletics timing and scoring systems',#4662,$,$); +#4664=IFCCLASSIFICATIONREFERENCE($,'Ss_75_10_88_86','Swimming pool timing and scoring systems',#4662,$,$); +#4665=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30','Signal systems',#4637,$,$); +#4666=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_35','Highway signal and control systems',#4665,$,$); +#4667=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_35_52','Motorway signal and control systems',#4666,$,$); +#4668=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_35_72','Road signal and control systems',#4666,$,$); +#4669=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_50','Marine signal systems',#4665,$,$); +#4670=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_60','Obstacle beacon systems',#4665,$,$); +#4671=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_70','Railway signal and control systems',#4665,$,$); +#4672=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_70_02','Automatic train operation (ATO) systems',#4671,$,$); +#4673=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_70_03','Automatic train protection (ATP) systems',#4671,$,$); +#4674=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_70_05','Automatic warning systems (AWS)',#4671,$,$); +#4675=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_70_15','Communications based train control (CBTC) systems',#4671,$,$); +#4676=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_70_27','Emergency traction current discharge systems (ETCDS)',#4671,$,$); +#4677=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_70_30','Fixed block signalling systems',#4671,$,$); +#4678=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_70_53','Moving block signalling systems',#4671,$,$); +#4679=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_70_70','Rail signal systems',#4671,$,$); +#4680=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_70_90','Train protection warning systems (TPWS)',#4671,$,$); +#4681=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_90','Tramway signal systems',#4665,$,$); +#4682=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_97','Waterway signal systems',#4665,$,$); +#4683=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_98','Wind direction indication systems',#4665,$,$); +#4684=IFCCLASSIFICATIONREFERENCE($,'Ss_75_30_98_96','Windsock systems',#4683,$,$); +#4685=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40','Security systems',#4637,$,$); +#4686=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_02','Access control systems',#4685,$,$); +#4687=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_02_05','Audio intercom systems',#4686,$,$); +#4688=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_02_11','Card access control systems',#4686,$,$); +#4689=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_02_94','Video intercom systems',#4686,$,$); +#4690=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_53','Monitoring systems',#4685,$,$); +#4691=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_53_86','Surveillance CCTV systems',#4690,$,$); +#4692=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_53_90','Train dispatch CCTV systems',#4690,$,$); +#4693=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_53_95','Voice recording systems',#4690,$,$); +#4694=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_73','Security screening systems',#4685,$,$); +#4695=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_73_11','Cabin baggage screening systems',#4694,$,$); +#4696=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_73_60','Passenger screening systems',#4694,$,$); +#4697=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_75','Security detection alarm systems',#4685,$,$); +#4698=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_75_02','Aerospace security detection and warning systems',#4697,$,$); +#4699=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_75_40','Intruder detection and alarm systems',#4697,$,$); +#4700=IFCCLASSIFICATIONREFERENCE($,'Ss_75_40_75_50','Marine and waterway security detection and warning systems',#4697,$,$); +#4701=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50','Safety and protection systems',#4637,$,$); +#4702=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_11','Call and alarm systems',#4701,$,$); +#4703=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_11_05','Assistance call systems',#4702,$,$); +#4704=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_11_27','Emergency voice communication systems',#4702,$,$); +#4705=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_11_57','Nurse call systems',#4702,$,$); +#4706=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_11_95','Voice alarm systems',#4702,$,$); +#4707=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_15','Cathodic protection systems',#4701,$,$); +#4708=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_15_02','Adhesive backed zinc sheet anode systems',#4707,$,$); +#4709=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_15_09','Buried galvanic anode systems',#4707,$,$); +#4710=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_15_10','Buried impressed current anode systems',#4707,$,$); +#4711=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_15_27','Embedded impressed current anode systems',#4707,$,$); +#4712=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_15_28','Embedded zinc anode systems',#4707,$,$); +#4713=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_15_41','Immersed galvanic anode systems',#4707,$,$); +#4714=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_15_42','Immersed impressed current anode systems',#4707,$,$); +#4715=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_15_72','Recess mounted impressed current anode systems',#4707,$,$); +#4716=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_15_85','Surface mounted impressed current anode systems',#4707,$,$); +#4717=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_15_99','Zinc mesh in overlay systems',#4707,$,$); +#4718=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_26','Debris detection systems',#4701,$,$); +#4719=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_26_30','Foreign object debris (FOD) detection systems',#4718,$,$); +#4720=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_28','Detection and alarm systems',#4701,$,$); +#4721=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_28_05','Aspirating detection systems',#4720,$,$); +#4722=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_28_22','Domestic premises fire detection and alarm systems',#4720,$,$); +#4723=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_28_24','Duct smoke detector systems',#4720,$,$); +#4724=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_28_29','Fire detection and alarm systems',#4720,$,$); +#4725=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_28_30','Fixed gas detection and alarm systems',#4720,$,$); +#4726=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_28_32','Flow sample gas detection and alarm systems',#4720,$,$); +#4727=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_28_71','Refrigerant leak detection and alarm systems',#4720,$,$); +#4728=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_28_96','Water leak detection and alarm systems',#4720,$,$); +#4729=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_28_97','Water presence detection and alarm systems',#4720,$,$); +#4730=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_35','Healthcare imaging systems',#4701,$,$); +#4731=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_45','Electrical protection systems',#4701,$,$); +#4732=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_45_45','Lightning protection systems',#4731,$,$); +#4733=IFCCLASSIFICATIONREFERENCE($,'Ss_75_50_60','Patient monitoring and telemetry systems',#4701,$,$); +#4734=IFCCLASSIFICATIONREFERENCE($,'Ss_75_60','Environmental safety systems',#4637,$,$); +#4735=IFCCLASSIFICATIONREFERENCE($,'Ss_75_60_25','Earthquake warning systems',#4734,$,$); +#4736=IFCCLASSIFICATIONREFERENCE($,'Ss_75_60_30','Flood warning systems',#4734,$,$); +#4737=IFCCLASSIFICATIONREFERENCE($,'Ss_75_60_50','Meteorological detection and warning systems',#4734,$,$); +#4738=IFCCLASSIFICATIONREFERENCE($,'Ss_75_60_52','Meteorological instrumentation systems',#4734,$,$); +#4739=IFCCLASSIFICATIONREFERENCE($,'Ss_75_60_52_95','Weather observation systems',#4738,$,$); +#4740=IFCCLASSIFICATIONREFERENCE($,'Ss_75_60_70','Radiation detection and alarm systems',#4734,$,$); +#4741=IFCCLASSIFICATIONREFERENCE($,'Ss_75_60_75','Seismic instrumentation systems',#4734,$,$); +#4742=IFCCLASSIFICATIONREFERENCE($,'Ss_75_60_90','Tsunami warning systems',#4734,$,$); +#4743=IFCCLASSIFICATIONREFERENCE($,'Ss_75_60_95','Volcanic eruption warning systems',#4734,$,$); +#4744=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70','Control and management systems',#4637,$,$); +#4745=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_05','Airport control systems',#4744,$,$); +#4746=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_05_04','Automatic aircraft docking systems',#4745,$,$); +#4747=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_10','Bridge control systems',#4744,$,$); +#4748=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_20','Dam control systems',#4744,$,$); +#4749=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_35','Highway control systems',#4744,$,$); +#4750=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_50','Marine control systems',#4744,$,$); +#4751=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52','Mechanical engineering services control and management systems',#4744,$,$); +#4752=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_03','Air to air heat pump control systems',#4751,$,$); +#4753=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_14','Climatic ceiling panels and beams control systems',#4751,$,$); +#4754=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_15','Combined heat and power control systems',#4751,$,$); +#4755=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_16','Constant volume air conditioning control systems',#4751,$,$); +#4756=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_17','Cooling system control systems',#4751,$,$); +#4757=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_23','Domestic heating system control systems',#4751,$,$); +#4758=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_28','Extract ventilation control systems',#4751,$,$); +#4759=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_29','Fan coil unit air conditioning control systems',#4751,$,$); +#4760=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_32','Fuel supply control systems',#4751,$,$); +#4761=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_33','Gas fired heating control systems',#4751,$,$); +#4762=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_36','Heating system control systems',#4751,$,$); +#4763=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_38','Heat pump control systems',#4751,$,$); +#4764=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_52','Mixed mode ventilation control systems',#4751,$,$); +#4765=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_56','Natural ventilation control systems',#4751,$,$); +#4766=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_70','Radiant heating control systems',#4751,$,$); +#4767=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_80','Smoke and heat detection extract control systems',#4751,$,$); +#4768=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_81','Smoke and heat detection shut down control systems',#4751,$,$); +#4769=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_85','Steam and condensate control systems',#4751,$,$); +#4770=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_93','Variable volume air conditioning control systems',#4751,$,$); +#4771=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_94','Ventilation control systems',#4751,$,$); +#4772=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_96','Water supply control systems',#4751,$,$); +#4773=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_52_97','Water to air heat pump control systems',#4751,$,$); +#4774=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_54','Metering, monitoring and management systems',#4744,$,$); +#4775=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_54_03','Active water monitoring systems',#4774,$,$); +#4776=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_54_10','Building monitoring and management systems',#4774,$,$); +#4777=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_54_15','Communications monitoring and management systems',#4774,$,$); +#4778=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_54_25','Electricity metering systems',#4774,$,$); +#4779=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_54_30','Fuel metering systems',#4774,$,$); +#4780=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_54_60','Passive water monitoring systems',#4774,$,$); +#4781=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_54_95','Water metering systems',#4774,$,$); +#4782=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_72','Road control systems',#4744,$,$); +#4783=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85','Structural monitoring systems',#4744,$,$); +#4784=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85_18','Crack gauge monitoring systems',#4783,$,$); +#4785=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85_27','Electrolevel monitoring systems',#4783,$,$); +#4786=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85_30','Fibre optic monitoring systems',#4783,$,$); +#4787=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85_47','Liquid levelling monitoring systems',#4783,$,$); +#4788=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85_48','Load cell monitoring systems',#4783,$,$); +#4789=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85_62','Piezometer monitoring systems',#4783,$,$); +#4790=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85_66','Precise levelling monitoring systems',#4783,$,$); +#4791=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85_67','Prism monitoring systems',#4783,$,$); +#4792=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85_84','Strain gauge monitoring systems',#4783,$,$); +#4793=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85_86','Sub-surface monitoring array systems',#4783,$,$); +#4794=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85_87','Tape extensometer monitoring systems',#4783,$,$); +#4795=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85_90','Tilt sensor monitoring systems',#4783,$,$); +#4796=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_85_92','Total station monitoring systems',#4783,$,$); +#4797=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_90','Traffic monitoring systems',#4744,$,$); +#4798=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_90_90','Traffic enforcement camera systems',#4797,$,$); +#4799=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_96','Water supply and wastewater control systems',#4744,$,$); +#4800=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_96_21','Desludging control systems',#4799,$,$); +#4801=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_96_30','Flow measurement and control systems',#4799,$,$); +#4802=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_96_96','Wastewater supply control systems',#4799,$,$); +#4803=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_96_98','Water supply quality control systems',#4799,$,$); +#4804=IFCCLASSIFICATIONREFERENCE($,'Ss_75_70_97','Waterway control systems',#4744,$,$); +#4805=IFCCLASSIFICATIONREFERENCE($,'Ss_75_90','Ticket management systems',#4637,$,$); +#4806=IFCCLASSIFICATIONREFERENCE($,'Ss_75_90_80','Ticketing systems',#4805,$,$); +#4807=IFCCLASSIFICATIONREFERENCE($,'Ss_75_90_93','Ticket validation systems',#4805,$,$); +#4808=IFCCLASSIFICATIONREFERENCE($,'Ss_75_90_93_11','Card reading systems',#4807,$,$); +#4809=IFCCLASSIFICATIONREFERENCE($,'Ss_75_90_93_60','Passenger check-in systems',#4807,$,$); +#4810=IFCCLASSIFICATIONREFERENCE($,'Ss_75_90_93_88','Ticket reading systems',#4807,$,$); +#4811=IFCCLASSIFICATIONREFERENCE($,'Ss_75_95','Temporary communications, security, safety, control and protection systems',#4637,$,$); +#4812=IFCCLASSIFICATIONREFERENCE($,'Ss_80','Transport systems',#2697,$,$); +#4813=IFCCLASSIFICATIONREFERENCE($,'Ss_80_10','Cable transport systems',#4812,$,$); +#4814=IFCCLASSIFICATIONREFERENCE($,'Ss_80_10_05','Aerial tram systems',#4813,$,$); +#4815=IFCCLASSIFICATIONREFERENCE($,'Ss_80_10_10','Cable car systems',#4813,$,$); +#4816=IFCCLASSIFICATIONREFERENCE($,'Ss_80_10_15','Chairlift systems',#4813,$,$); +#4817=IFCCLASSIFICATIONREFERENCE($,'Ss_80_10_30','Funicular systems',#4813,$,$); +#4818=IFCCLASSIFICATIONREFERENCE($,'Ss_80_10_35','Gondola systems',#4813,$,$); +#4819=IFCCLASSIFICATIONREFERENCE($,'Ss_80_10_70','Ropeway tow systems',#4813,$,$); +#4820=IFCCLASSIFICATIONREFERENCE($,'Ss_80_10_85','Surface lift systems',#4813,$,$); +#4821=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20','Conveying systems',#4812,$,$); +#4822=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_05','Automatic guided vehicle systems',#4821,$,$); +#4823=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_06','Baggage handling systems',#4821,$,$); +#4824=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_06_04','Airport baggage handling systems',#4823,$,$); +#4825=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_10','Bulk material conveying systems',#4821,$,$); +#4826=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_11','Cargo handling systems',#4821,$,$); +#4827=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_23','Document conveying systems',#4821,$,$); +#4828=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_23_65','Pneumatic document conveying systems',#4827,$,$); +#4829=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_60','Parcel sorting systems',#4821,$,$); +#4830=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_62','People conveying systems',#4821,$,$); +#4831=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_62_28','Escalator systems',#4830,$,$); +#4832=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_62_53','Moving walkway systems',#4830,$,$); +#4833=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_63','Piece conveying systems',#4821,$,$); +#4834=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_63_59','Overhead piece conveying systems',#4833,$,$); +#4835=IFCCLASSIFICATIONREFERENCE($,'Ss_80_20_65','Pneumatic conveying systems',#4821,$,$); +#4836=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30','Crane and hoist systems',#4812,$,$); +#4837=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_15','Crane systems',#4836,$,$); +#4838=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_15_10','Bulk handling crane systems',#4837,$,$); +#4839=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_15_15','Container handling crane systems',#4837,$,$); +#4840=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_15_59','Overhead crane systems',#4837,$,$); +#4841=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_20','Derrick systems',#4836,$,$); +#4842=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_25','Dynamic permanent access and safety equipment systems',#4836,$,$); +#4843=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_25_30','Fixed rig suspended access systems',#4842,$,$); +#4844=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_25_32','Gantry access systems',#4842,$,$); +#4845=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_25_35','Guided type fall arrest systems',#4842,$,$); +#4846=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_25_50','Mobile rig monorail suspended access systems',#4842,$,$); +#4847=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_25_52','Mobile rig tracked suspended access systems',#4842,$,$); +#4848=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_25_55','Mobile rig trackless suspended access systems',#4842,$,$); +#4849=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_25_75','Robotic cleaning systems',#4842,$,$); +#4850=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_25_80','Single point anchorage fall arrest systems',#4842,$,$); +#4851=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_25_90','Travelling ladder access systems',#4842,$,$); +#4852=IFCCLASSIFICATIONREFERENCE($,'Ss_80_30_40','Hoist systems',#4836,$,$); +#4853=IFCCLASSIFICATIONREFERENCE($,'Ss_80_50','Lift systems',#4812,$,$); +#4854=IFCCLASSIFICATIONREFERENCE($,'Ss_80_50_60','Passenger and goods lift systems',#4853,$,$); +#4855=IFCCLASSIFICATIONREFERENCE($,'Ss_80_50_60_26','Electric lift systems',#4854,$,$); +#4856=IFCCLASSIFICATIONREFERENCE($,'Ss_80_50_60_39','Hydraulic lift systems',#4854,$,$); +#4857=IFCCLASSIFICATIONREFERENCE($,'Ss_80_50_60_50','Manual dumbwaiter systems',#4854,$,$); +#4858=IFCCLASSIFICATIONREFERENCE($,'Ss_80_50_60_60','Paternoster systems',#4854,$,$); +#4859=IFCCLASSIFICATIONREFERENCE($,'Ss_80_50_60_65','Powered homelift systems',#4854,$,$); +#4860=IFCCLASSIFICATIONREFERENCE($,'Ss_80_50_60_83','Stairlift systems',#4854,$,$); +#4861=IFCCLASSIFICATIONREFERENCE($,'Ss_80_50_60_85','Step lift systems',#4854,$,$); +#4862=IFCCLASSIFICATIONREFERENCE($,'Ss_80_50_60_94','Vertical platform lift systems',#4854,$,$); +#4863=IFCCLASSIFICATIONREFERENCE($,'Ss_80_50_94','Vehicle and boat stacking systems',#4853,$,$); +#4864=IFCCLASSIFICATIONREFERENCE($,'Ss_80_50_96','Warehouse stacking systems',#4853,$,$); +#4865=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70','Track systems',#4812,$,$); +#4866=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70_46','Level crossing systems',#4865,$,$); +#4867=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70_46_60','Pedestrian level crossing systems',#4866,$,$); +#4868=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70_46_93','User worked level crossing systems',#4866,$,$); +#4869=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70_46_95','Vehicular level crossing systems',#4866,$,$); +#4870=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70_50','Monorail systems',#4865,$,$); +#4871=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70_70','Rail track systems',#4865,$,$); +#4872=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70_70_06','Ballasted rail track systems',#4871,$,$); +#4873=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70_70_27','Embedded rail systems',#4871,$,$); +#4874=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70_70_56','Non-embedded slab track rail systems',#4871,$,$); +#4875=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70_70_65','Precast track bed systems',#4871,$,$); +#4876=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70_89','Train arrestor systems',#4865,$,$); +#4877=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70_89_30','Fixed train arrestor systems',#4876,$,$); +#4878=IFCCLASSIFICATIONREFERENCE($,'Ss_80_70_89_50','Moveable train arrestor systems',#4876,$,$); +#4879=IFCCLASSIFICATIONREFERENCE($,'Ss_80_80','Turntable systems',#4812,$,$); +#4880=IFCCLASSIFICATIONREFERENCE($,'Ss_80_80_20','Display turntable systems',#4879,$,$); +#4881=IFCCLASSIFICATIONREFERENCE($,'Ss_80_80_30','Floor turntable systems',#4879,$,$); +#4882=IFCCLASSIFICATIONREFERENCE($,'Ss_80_80_40','Industrial turntable systems',#4879,$,$); +#4883=IFCCLASSIFICATIONREFERENCE($,'Ss_80_80_70','Railway turntable systems',#4879,$,$); +#4884=IFCCLASSIFICATIONREFERENCE($,'Ss_80_80_85','Stage turntable systems',#4879,$,$); +#4885=IFCCLASSIFICATIONREFERENCE($,'Ss_80_90','Vehicle access systems',#4812,$,$); +#4886=IFCCLASSIFICATIONREFERENCE($,'Ss_80_90_05','Aircraft passenger loading bridge systems',#4885,$,$); +#4887=IFCCLASSIFICATIONREFERENCE($,'Ss_80_90_05_60','Passenger loading bridge systems',#4886,$,$); +#4888=IFCCLASSIFICATIONREFERENCE($,'Ss_80_90_70','Rocket passenger access systems',#4885,$,$); +#4889=IFCCLASSIFICATIONREFERENCE($,'Ss_80_90_75','Ship passenger loading bridge systems',#4885,$,$); +#4890=IFCCLASSIFICATIONREFERENCE($,'Ss_80_95','Temporary transport systems',#4812,$,$); +#4891=IFCCLASSIFICATIONREFERENCE($,'Ss_85','Process engineering systems',#2697,$,$); +#4892=IFCCLASSIFICATIONREFERENCE($,'Ss_85_72','Robotic systems',#4891,$,$); +#4893=IFCCLASSIFICATIONREFERENCE($,'Ss_85_95','Temporary process engineering systems',#4891,$,$); +#4894=IFCCLASSIFICATIONREFERENCE($,'Ss_90','Soft facility management systems',#2697,$,$); +#4895=IFCCLASSIFICATIONREFERENCE($,'Ss_90_05','Demand for space',#4894,$,$); +#4896=IFCCLASSIFICATIONREFERENCE($,'Ss_90_06','Demand for technical infrastructure',#4894,$,$); +#4897=IFCCLASSIFICATIONREFERENCE($,'Ss_90_07','Demand for cleaning',#4894,$,$); +#4898=IFCCLASSIFICATIONREFERENCE($,'Ss_90_08','Demand related to outdoor space',#4894,$,$); +#4899=IFCCLASSIFICATIONREFERENCE($,'Ss_90_09','Workplace',#4894,$,$); +#4900=IFCCLASSIFICATIONREFERENCE($,'Ss_90_10','Specific demand related to space and infrastructure',#4894,$,$); +#4901=IFCCLASSIFICATIONREFERENCE($,'Ss_90_11','Demand for health, safety and security',#4894,$,$); +#4902=IFCCLASSIFICATIONREFERENCE($,'Ss_90_12','Hospitality demands',#4894,$,$); +#4903=IFCCLASSIFICATIONREFERENCE($,'Ss_90_13','Demand for information and communication',#4894,$,$); +#4904=IFCCLASSIFICATIONREFERENCE($,'Ss_90_14','Demand for logistics',#4894,$,$); +#4905=IFCCLASSIFICATIONREFERENCE($,'Ss_90_15','Demand for integrated management, consultancy and administration',#4894,$,$); +#4906=IFCCLASSIFICATIONREFERENCE($,'Ss_90_20','Specific demand of administrative, commercial and protective services',#4894,$,$); +#4907=IFCCLASSIFICATIONREFERENCE($,'Ss_90_25','Specific demand of cultural, educational, scientific and information organizations',#4894,$,$); +#4908=IFCCLASSIFICATIONREFERENCE($,'Ss_90_30','Specific demand of industrial organizations',#4894,$,$); +#4909=IFCCLASSIFICATIONREFERENCE($,'Ss_90_35','Specific demand of medical, health, welfare and sanitary organizations',#4894,$,$); +#4910=IFCCLASSIFICATIONREFERENCE($,'Ss_90_40','Specific demand of recreational organizations',#4894,$,$); +#4911=IFCCLASSIFICATIONREFERENCE($,'Ss_90_45','Specific demand of residential organizations',#4894,$,$); +#4912=IFCCLASSIFICATIONREFERENCE($,'Ss_90_50','Specific demand of disposal organizations',#4894,$,$); +#4913=IFCCLASSIFICATIONREFERENCE($,'Ss_90_55','Specific demand of piped supply organizations',#4894,$,$); +#4914=IFCCLASSIFICATIONREFERENCE($,'Ss_90_60','Specific demand of heating, cooling and refrigeration organizations',#4894,$,$); +#4915=IFCCLASSIFICATIONREFERENCE($,'Ss_90_65','Specific demand of ventilation and air conditioning organizations',#4894,$,$); +#4916=IFCCLASSIFICATIONREFERENCE($,'Ss_90_70','Specific demand of electrical organizations',#4894,$,$); +#4917=IFCCLASSIFICATIONREFERENCE($,'Ss_90_75','Specific demand of communications, security, safety and protection organisations',#4894,$,$); +#4918=IFCCLASSIFICATIONREFERENCE($,'Ss_90_80','Specific demand of rail organizations',#4894,$,$); +#4919=IFCCLASSIFICATIONREFERENCE($,'Ss_90_81','Specific demand of road organizations',#4894,$,$); +#4920=IFCCLASSIFICATIONREFERENCE($,'Ss_90_82','Specific demand of marine and waterway organizations',#4894,$,$); +#4921=IFCCLASSIFICATIONREFERENCE($,'Ss_90_83','Specific demand of cable transport organizations',#4894,$,$); +#4922=IFCCLASSIFICATIONREFERENCE($,'Ss_90_84','Specific demand of aerospace organizations',#4894,$,$); +#4923=IFCCLASSIFICATIONREFERENCE($,'Pr','Products',#2,$,$); +#4924=IFCCLASSIFICATIONREFERENCE($,'Pr_15','Preparatory products',#4923,$,$); +#4925=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31','Formless preparatory products',#4924,$,$); +#4926=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04','Applied cleaning and treatment products',#4925,$,$); +#4927=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_02','Acid neutralization products',#4926,$,$); +#4928=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_06','Biocidal cleaning solutions',#4926,$,$); +#4929=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_10','Chemical absorbent products',#4926,$,$); +#4930=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_11','Chemical cleaning gels and liquids',#4926,$,$); +#4931=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_12','Chemical poultices',#4926,$,$); +#4932=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_13','Cleaners',#4926,$,$); +#4933=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_14','Cleaning agents',#4926,$,$); +#4934=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_15','Concrete surface retarders',#4926,$,$); +#4935=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_16','Concrete treatment surface and injection chemicals',#4926,$,$); +#4936=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_20','Curing compounds',#4926,$,$); +#4937=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_23','De-icing chemicals',#4926,$,$); +#4938=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_34','Graffiti-removing chemicals',#4926,$,$); +#4939=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_35','Grit',#4926,$,$); +#4940=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_53','Mould removers',#4926,$,$); +#4941=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_58','Oil-absorbent products',#4926,$,$); +#4942=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_60','Paint strippers',#4926,$,$); +#4943=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_64','Plain poultices',#4926,$,$); +#4944=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_72','Rock salt',#4926,$,$); +#4945=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_77','Shampoos',#4926,$,$); +#4946=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_80','Snow clearing chemicals',#4926,$,$); +#4947=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_81','Solvents',#4926,$,$); +#4948=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_84','Spot-removing chemicals',#4926,$,$); +#4949=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_85','Sugar soap',#4926,$,$); +#4950=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_04_86','Surface cleaners',#4926,$,$); +#4951=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_12','Chemical soils stabilizers',#4925,$,$); +#4952=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_12_42','Injectable resinous soil stabilizers',#4951,$,$); +#4953=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26','Excavated earth and fill materials',#4925,$,$); +#4954=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_02','Asphalt arisings granular unbound mixtures',#4953,$,$); +#4955=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_07','Bentonite',#4953,$,$); +#4956=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_13','Chalk',#4953,$,$); +#4957=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_14','Clay',#4953,$,$); +#4958=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_15','Coarse no fines rubble fill materials',#4953,$,$); +#4959=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_17','Cohesive material',#4953,$,$); +#4960=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_18','Close-graded granular unbound mixtures',#4953,$,$); +#4961=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_26','Earth',#4953,$,$); +#4962=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_31','Glass bottles',#4953,$,$); +#4963=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_33','Graded granular fill materials',#4953,$,$); +#4964=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_34','Graded natural granular fill materials',#4953,$,$); +#4965=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_35','Graded recycled granular fill materials',#4953,$,$); +#4966=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_36','Hardcore',#4953,$,$); +#4967=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_39','Higher fines content well-graded granular mixtures',#4953,$,$); +#4968=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_42','Hoggin',#4953,$,$); +#4969=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_46','Landscape area fill materials',#4953,$,$); +#4970=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_50','Made ground',#4953,$,$); +#4971=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_58','Open-graded granular unbound mixtures',#4953,$,$); +#4972=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_71','River deposits',#4953,$,$); +#4973=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_75','Sand',#4953,$,$); +#4974=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_90','Topsoil',#4953,$,$); +#4975=IFCCLASSIFICATIONREFERENCE($,'Pr_15_31_26_96','Well-graded granular unbound mixtures',#4953,$,$); +#4976=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57','Non-rigid sheet, mat and strip preparatory products',#4924,$,$); +#4977=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_04','Applied cleaning and repair products',#4976,$,$); +#4978=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_04_34','Graffiti-removing wipes',#4977,$,$); +#4979=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_25','Geocells',#4976,$,$); +#4980=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_25_03','Acrylonitrile butadiene styrene (ABS) geocell boards',#4979,$,$); +#4981=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_25_04','Acrylonitrile butadiene styrene (ABS) geocell sheets',#4979,$,$); +#4982=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_25_32','Geocell boards',#4979,$,$); +#4983=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_25_33','Geocell sheets',#4979,$,$); +#4984=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_25_35','Heavy-duty polystyrene geocell boards',#4979,$,$); +#4985=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_25_36','Heavy-duty polystyrene geocell sheets',#4979,$,$); +#4986=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_25_39','High density polyethylene (PE-HD) geocell boards',#4979,$,$); +#4987=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_25_40','High density polyethylene (PE-HD) geocell sheets',#4979,$,$); +#4988=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_25_57','Needle-punched polyester linen',#4979,$,$); +#4989=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_25_70','Polyester strips',#4979,$,$); +#4990=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_25_74','Polypropylene geocell boards',#4979,$,$); +#4991=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_25_75','Polypropylene geocell sheets',#4979,$,$); +#4992=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_27','Geocomposites',#4976,$,$); +#4993=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_27_33','Geocomposite sheets',#4992,$,$); +#4994=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_27_36','Geocomposite studded sheets',#4992,$,$); +#4995=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_27_38','Geomembrane geogrid composite sheets',#4992,$,$); +#4996=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_27_39','Geosynthetic clay liners (GCLs)',#4992,$,$); +#4997=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_27_43','Geotextile geogrid composite sheets',#4992,$,$); +#4998=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_27_45','Geotextile geomembrane composite sheets',#4992,$,$); +#4999=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_27_47','Geotextile geonet composite sheets',#4992,$,$); +#5000=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_27_49','Geotextile plastics composite sheets',#4992,$,$); +#5001=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_27_60','Plastics geocomposite sheets',#4992,$,$); +#5002=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_30','Geomembranes',#4976,$,$); +#5003=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_33','Geosynthetics',#4976,$,$); +#5004=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_33_36','Geogrids',#5003,$,$); +#5005=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_33_37','Geomats',#5003,$,$); +#5006=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_33_38','Geonets',#5003,$,$); +#5007=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_33_41','High density polyethylene (PE-HD) geogrids',#5003,$,$); +#5008=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_33_42','High density polyethylene (PE-HD) geonets',#5003,$,$); +#5009=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_33_64','Plastics geogrids',#5003,$,$); +#5010=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_33_75','Polyester geogrids',#5003,$,$); +#5011=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_33_77','Polyethylene geomats',#5003,$,$); +#5012=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_33_79','Polymeric rib geonets',#5003,$,$); +#5013=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_33_80','Polyolefin geomats',#5003,$,$); +#5014=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_33_85','Spun-bonded polypropylene (PP) membranes',#5003,$,$); +#5015=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_33_97','Woven polypropylene (PP) membranes',#5003,$,$); +#5016=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_35','Geotextiles',#4976,$,$); +#5017=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_35_56','Natural material geotextiles',#5016,$,$); +#5018=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_35_57','Needle-punched nonwoven geotextiles',#5016,$,$); +#5019=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_35_61','Plastics geotextiles',#5016,$,$); +#5020=IFCCLASSIFICATIONREFERENCE($,'Pr_15_57_35_88','Thermally-bonded nonwoven geotextiles',#5016,$,$); +#5021=IFCCLASSIFICATIONREFERENCE($,'Pr_15_71','Rigid board, panel and sheet preparatory products',#4924,$,$); +#5022=IFCCLASSIFICATIONREFERENCE($,'Pr_15_71_90','Trench boards and sheets',#5021,$,$); +#5023=IFCCLASSIFICATIONREFERENCE($,'Pr_15_71_90_90','Trench boards',#5022,$,$); +#5024=IFCCLASSIFICATIONREFERENCE($,'Pr_15_71_90_91','Trench sheets',#5022,$,$); +#5025=IFCCLASSIFICATIONREFERENCE($,'Pr_15_93','Unit preparatory products',#4924,$,$); +#5026=IFCCLASSIFICATIONREFERENCE($,'Pr_15_93_30','Fill blocks',#5025,$,$); +#5027=IFCCLASSIFICATIONREFERENCE($,'Pr_15_93_30_28','Expanded polystyrene (EPS) fill blocks',#5026,$,$); +#5028=IFCCLASSIFICATIONREFERENCE($,'Pr_20','Structure and general products',#4923,$,$); +#5029=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29','Fastener products',#5028,$,$); +#5030=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03','Anchors and components',#5029,$,$); +#5031=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_04','Anchor blocks',#5030,$,$); +#5032=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_05','Anchor rails',#5030,$,$); +#5033=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_10','Carbon steel anchor plates',#5030,$,$); +#5034=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_11','Carbon steel chemical anchor rods',#5030,$,$); +#5035=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_12','Carbon steel chemical anchor sockets',#5030,$,$); +#5036=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_13','Carbon steel post base plates',#5030,$,$); +#5037=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_14','Carbon steel post spikes',#5030,$,$); +#5038=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_15','Cavity anchors',#5030,$,$); +#5039=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_16','Chemical anchor capsules',#5030,$,$); +#5040=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_17','Chemical anchor cartridges',#5030,$,$); +#5041=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_18','Chemical anchors',#5030,$,$); +#5042=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_28','Expansion anchors',#5030,$,$); +#5043=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_30','Fixing discs',#5030,$,$); +#5044=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_31','Framing anchors',#5030,$,$); +#5045=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_32','Framing fasteners',#5030,$,$); +#5046=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_33','Ground anchor heads',#5030,$,$); +#5047=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_34','Ground plate anchors',#5030,$,$); +#5048=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_35','Grouted ground anchors',#5030,$,$); +#5049=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_36','Hammer-in fasteners',#5030,$,$); +#5050=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_44','J-pins',#5030,$,$); +#5051=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_47','Lifting anchors',#5030,$,$); +#5052=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_48','Lifting hoops',#5030,$,$); +#5053=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_66','Prestressing anchors',#5030,$,$); +#5054=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_72','Rock bolts',#5030,$,$); +#5055=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_73','Rock dowels',#5030,$,$); +#5056=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_77','Socket anchors',#5030,$,$); +#5057=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_78','Solar module roof anchors',#5030,$,$); +#5058=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_79','Split rings',#5030,$,$); +#5059=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_80','Sprayed concrete anchor studs',#5030,$,$); +#5060=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_81','Sprayed concrete ties',#5030,$,$); +#5061=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_82','Stainless steel anchor plates',#5030,$,$); +#5062=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_83','Stainless steel chemical anchor rods',#5030,$,$); +#5063=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_84','Stainless steel chemical anchor sockets',#5030,$,$); +#5064=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_86','Structural anchors',#5030,$,$); +#5065=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_88','Threaded anchors',#5030,$,$); +#5066=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_92','Undercut anchors',#5030,$,$); +#5067=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_03_97','Wedge anchors',#5030,$,$); +#5068=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_04','Angle fasteners',#5029,$,$); +#5069=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_04_26','Equal angles fasteners',#5068,$,$); +#5070=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_04_27','Equipment fasteners',#5068,$,$); +#5071=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08','Bolts and accessories',#5029,$,$); +#5072=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_04','Anchor bolts',#5071,$,$); +#5073=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_07','Black hexagon nuts and bolts',#5071,$,$); +#5074=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_08','Bolt boxes',#5071,$,$); +#5075=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_11','Carbon steel hexagon headed nuts and bolts',#5071,$,$); +#5076=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_12','Carbon steel hook bolts (J-bolts)',#5071,$,$); +#5077=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_15','Coach (carriage) bolts and nuts',#5071,$,$); +#5078=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_18','Crossing bolts',#5071,$,$); +#5079=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_26','Elevator bolts',#5071,$,$); +#5080=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_27','Eye bolts',#5071,$,$); +#5081=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_28','Expanding bolts',#5071,$,$); +#5082=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_30','Fishplate bolts',#5071,$,$); +#5083=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_32','Flangeway bolts',#5071,$,$); +#5084=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_36','Hanger bolts',#5071,$,$); +#5085=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_38','Holding down bolt assemblies',#5071,$,$); +#5086=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_42','Indented bolts',#5071,$,$); +#5087=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_46','Lag bolts',#5071,$,$); +#5088=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_57','Nylon gutter bolts',#5071,$,$); +#5089=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_66','Preloaded bolt assemblies',#5071,$,$); +#5090=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_70','Rail securing bolts',#5071,$,$); +#5091=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_78','Shoulder bolts',#5071,$,$); +#5092=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_83','Stainless steel gutter bolts',#5071,$,$); +#5093=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_84','Stainless steel hexagon headed nuts and bolts',#5071,$,$); +#5094=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_85','Stainless steel hook bolts (J-bolts)',#5071,$,$); +#5095=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_86','Stud bolts',#5071,$,$); +#5096=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_08_92','U-bolts',#5071,$,$); +#5097=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_10','Bridge suspension cable accessories',#5029,$,$); +#5098=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_10_11','Cable sleeves',#5097,$,$); +#5099=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_10_12','Cable strand sockets',#5097,$,$); +#5100=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_10_13','Cast steel anchorage couplers',#5097,$,$); +#5101=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_10_14','Cast steel cable bands',#5097,$,$); +#5102=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_10_15','Cast steel saddles',#5097,$,$); +#5103=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_10_16','Cast steel suspender sockets',#5097,$,$); +#5104=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_10_21','Dampers',#5097,$,$); +#5105=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_10_79','Sleeve clamps',#5097,$,$); +#5106=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14','Clips, clamps and couplers',#5029,$,$); +#5107=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_07','Beam clamps',#5106,$,$); +#5108=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_08','Beam clips',#5106,$,$); +#5109=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_13','Circlips',#5106,$,$); +#5110=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_15','Coupler connections',#5106,$,$); +#5111=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_16','Colour pipe clips',#5106,$,$); +#5112=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_17','Copper clips',#5106,$,$); +#5113=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_22','Deck board clips',#5106,$,$); +#5114=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_24','Drainage pipe clips',#5106,$,$); +#5115=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_30','Fence panel clips',#5106,$,$); +#5116=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_31','Floor clips',#5106,$,$); +#5117=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_32','Frame cramps',#5106,$,$); +#5118=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_33','Glass panel fixing clips',#5106,$,$); +#5119=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_34','Glass-to-glass clips',#5106,$,$); +#5120=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_35','Glass-to-wall clips',#5106,$,$); +#5121=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_36','Girder clamps',#5106,$,$); +#5122=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_40','Iron clips',#5106,$,$); +#5123=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_45','Lift-off panel clips',#5106,$,$); +#5124=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_50','Masonry cramps',#5106,$,$); +#5125=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_65','Pipe clips',#5106,$,$); +#5126=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_68','Push-fit panel clips',#5106,$,$); +#5127=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_76','Security glazing clips',#5106,$,$); +#5128=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_79','Shackles',#5106,$,$); +#5129=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_82','Stainless steel spring clips',#5106,$,$); +#5130=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_84','Standing seam fixed clips',#5106,$,$); +#5131=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_85','Standing seam sliding clips',#5106,$,$); +#5132=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_86','Steel clips',#5106,$,$); +#5133=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_87','Suspended ceiling clips',#5106,$,$); +#5134=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_14_90','Truss clips',#5106,$,$); +#5135=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23','Dowels and rods',#5029,$,$); +#5136=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_11','Carbon steel dowel bars',#5135,$,$); +#5137=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_12','Carbon steel rods',#5135,$,$); +#5138=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_22','Dowel bar caps',#5135,$,$); +#5139=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_23','Dowel-retaining fasteners',#5135,$,$); +#5140=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_30','Fibre-reinforced plastics dowels',#5135,$,$); +#5141=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_36','Hardwood dowels',#5135,$,$); +#5142=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_40','Hot welding rods',#5135,$,$); +#5143=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_50','Masonry dowels',#5135,$,$); +#5144=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_52','Metal dowels, pins and rods',#5135,$,$); +#5145=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_65','Plastics dowel bar caps',#5135,$,$); +#5146=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_80','Softwood dowels',#5135,$,$); +#5147=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_83','Stainless steel dowel bars',#5135,$,$); +#5148=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_84','Stainless steel rods',#5135,$,$); +#5149=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_23_92','U-pins',#5135,$,$); +#5150=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_29','Ferrules and sleeves',#5029,$,$); +#5151=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_29_23','Dowel bar sleeves',#5150,$,$); +#5152=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_29_29','Ferrules',#5150,$,$); +#5153=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_29_62','Plastics pile sleeves',#5150,$,$); +#5154=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_29_66','Pre-stressed reinforcement cable conduits',#5150,$,$); +#5155=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_29_84','Spacer sleeves',#5150,$,$); +#5156=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_29_96','Wire-crimp ferrules',#5150,$,$); +#5157=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_30','Fixing lugs',#5029,$,$); +#5158=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_30_11','Cable fixing lugs',#5157,$,$); +#5159=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_30_12','Carbon steel fixing lugs',#5157,$,$); +#5160=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_30_24','Door fixing lugs',#5157,$,$); +#5161=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_30_31','Furniture floor fixing lugs',#5157,$,$); +#5162=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_30_32','Furniture wall fixing lugs',#5157,$,$); +#5163=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_30_96','Window fixing lugs',#5157,$,$); +#5164=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_31','Flat and folded plate fasteners',#5029,$,$); +#5165=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_31_08','Bolted joint connectors',#5164,$,$); +#5166=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_31_12','Carbon steel nailing plates',#5164,$,$); +#5167=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_31_13','Carbon steel punched metal plate fasteners',#5164,$,$); +#5168=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_31_44','Joist hangers',#5164,$,$); +#5169=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_31_52','Mortise and tenon joint oak pegs',#5164,$,$); +#5170=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_31_84','Stainless steel nailing plates',#5164,$,$); +#5171=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_31_85','Stainless steel punched metal plate fasteners',#5164,$,$); +#5172=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_34','Glass fixing plates, brackets and anchors',#5029,$,$); +#5173=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_34_16','Cast brass glass fixing brackets',#5172,$,$); +#5174=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_34_34','Glass fin splice plates',#5172,$,$); +#5175=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_34_35','Glass patch plates',#5172,$,$); +#5176=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_34_85','Stainless steel glass block panel anchors',#5172,$,$); +#5177=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_34_86','Stainless steel point connectors',#5172,$,$); +#5178=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56','Nails',#5029,$,$); +#5179=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_02','Aluminium nails',#5178,$,$); +#5180=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_03','Annular nails',#5178,$,$); +#5181=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_11','Carbon steel nails',#5178,$,$); +#5182=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_12','Carbon steel wire nails',#5178,$,$); +#5183=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_14','Clout head nails',#5178,$,$); +#5184=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_15','Copper nails',#5178,$,$); +#5185=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_16','Corrugated fasteners',#5178,$,$); +#5186=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_19','Cut clasp nails',#5178,$,$); +#5187=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_20','Cut floor brads',#5178,$,$); +#5188=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_36','Hardboard nails',#5178,$,$); +#5189=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_48','Lost head (round) nails',#5178,$,$); +#5190=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_50','Masonry nails',#5178,$,$); +#5191=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_59','Oval wire nails',#5178,$,$); +#5192=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_60','Panel pins',#5178,$,$); +#5193=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_65','Power driven nails',#5178,$,$); +#5194=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_78','Shot-fire nails',#5178,$,$); +#5195=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_82','Sprigs',#5178,$,$); +#5196=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_83','Spring-head roofing nails',#5178,$,$); +#5197=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_84','Square twisted nails',#5178,$,$); +#5198=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_85','Stainless steel nails',#5178,$,$); +#5199=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_86','Staples',#5178,$,$); +#5200=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_87','Tacks',#5178,$,$); +#5201=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_56_93','Upholstery nails',#5178,$,$); +#5202=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57','Nuts',#5029,$,$); +#5203=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_01','Acorn nuts',#5202,$,$); +#5204=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_02','Aerotite nuts',#5202,$,$); +#5205=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_11','Cage nuts',#5202,$,$); +#5206=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_12','Captive nuts',#5202,$,$); +#5207=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_13','Castle nuts',#5202,$,$); +#5208=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_23','Dome (cap) nuts',#5202,$,$); +#5209=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_30','Flange nuts',#5202,$,$); +#5210=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_35','Hard lock nuts',#5202,$,$); +#5211=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_36','Half nuts',#5202,$,$); +#5212=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_37','Heavy hex nuts',#5202,$,$); +#5213=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_38','Hex nuts',#5202,$,$); +#5214=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_44','Jam nuts',#5202,$,$); +#5215=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_45','K-lock nuts',#5202,$,$); +#5216=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_50','Manifold nuts',#5202,$,$); +#5217=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_56','Nylon-insert jam nuts',#5202,$,$); +#5218=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_57','Nylon-insert lock nuts',#5202,$,$); +#5219=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_66','Prevailing torque lock nuts',#5202,$,$); +#5220=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_75','Self-locking nuts',#5202,$,$); +#5221=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_76','Serrated flange nuts',#5202,$,$); +#5222=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_80','Slotted nuts',#5202,$,$); +#5223=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_83','Square nuts',#5202,$,$); +#5224=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_84','Stover nuts',#5202,$,$); +#5225=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_85','Stud connector (coupling) nuts',#5202,$,$); +#5226=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_88','Tee nuts',#5202,$,$); +#5227=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_57_96','Wing nuts',#5202,$,$); +#5228=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60','Packings, washers and spacers',#5029,$,$); +#5229=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_07','Bituminous felt packers',#5228,$,$); +#5230=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_17','Crinkle washers',#5228,$,$); +#5231=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_20','Cup (finishing) washers',#5228,$,$); +#5232=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_28','External tooth lock (shake-proof) washers',#5228,$,$); +#5233=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_29','Fender washers',#5228,$,$); +#5234=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_30','Fibre washers',#5228,$,$); +#5235=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_31','Flat washers',#5228,$,$); +#5236=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_32','Formwork cover spacers',#5228,$,$); +#5237=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_34','Grommets',#5228,$,$); +#5238=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_36','Hardwood packers',#5228,$,$); +#5239=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_37','Hardwood wedges',#5228,$,$); +#5240=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_42','Internal tooth lock (shake-proof) washers',#5228,$,$); +#5241=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_58','Ogee washers',#5228,$,$); +#5242=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_59','Open push',#5228,$,$); +#5243=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_60','Packings',#5228,$,$); +#5244=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_61','Parallel circumferential packings',#5228,$,$); +#5245=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_62','Penny (dock) washers',#5228,$,$); +#5246=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_63','Plate (square) washers',#5228,$,$); +#5247=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_64','Plywood packers',#5228,$,$); +#5248=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_65','Polyethylene packers',#5228,$,$); +#5249=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_75','Serrated washers',#5228,$,$); +#5250=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_76','Sealing washers',#5228,$,$); +#5251=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_77','Shims and folding wedges',#5228,$,$); +#5252=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_81','Softwood packs',#5228,$,$); +#5253=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_82','Softwood wedges',#5228,$,$); +#5254=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_84','Sprung (split lock) washers',#5228,$,$); +#5255=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_87','Tapered circumferential packings',#5228,$,$); +#5256=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_60_96','Washers',#5228,$,$); +#5257=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_63','Plugs',#5029,$,$); +#5258=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_63_50','Masonry plugs',#5257,$,$); +#5259=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_63_63','Plastics plugs',#5257,$,$); +#5260=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_63_84','Studded cavity drainage membrane plugs',#5257,$,$); +#5261=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_63_85','Surface plugs and pellets',#5257,$,$); +#5262=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70','Rail fasteners',#5029,$,$); +#5263=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_02','Adjustable rail clips',#5262,$,$); +#5264=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_09','Bull head rail keys',#5262,$,$); +#5265=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_11','Cast-in rail clip shoulders',#5262,$,$); +#5266=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_13','Clamp brackets',#5262,$,$); +#5267=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_22','Distance block bolts',#5262,$,$); +#5268=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_31','Fishplates',#5262,$,$); +#5269=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_32','Fishwashers',#5262,$,$); +#5270=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_36','Heel blocks',#5262,$,$); +#5271=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_37','Heel block bolts',#5262,$,$); +#5272=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_41','Insulated fishplates',#5262,$,$); +#5273=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_46','Long defect fishplates',#5262,$,$); +#5274=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_68','Rail anchors',#5262,$,$); +#5275=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_69','Rail clamp assemblies',#5262,$,$); +#5276=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_70','Rail clips',#5262,$,$); +#5277=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_72','Rail joint clamps',#5262,$,$); +#5278=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_73','Rail foot insulators',#5262,$,$); +#5279=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_85','Stock rail anchor bolts',#5262,$,$); +#5280=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_87','Switch rail anchor',#5262,$,$); +#5281=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_70_96','Weldable rail clip shoulders',#5262,$,$); +#5282=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_71','Rivets',#5029,$,$); +#5283=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_71_08','Blind (pop) rivets',#5282,$,$); +#5284=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_71_24','Drive rivets',#5282,$,$); +#5285=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_71_30','Flush rivets',#5282,$,$); +#5286=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_71_31','Friction rivets',#5282,$,$); +#5287=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_71_59','Oscar rivets',#5282,$,$); +#5288=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_71_76','Self-pierce rivets',#5282,$,$); +#5289=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_71_77','Semi-tubular rivets',#5282,$,$); +#5290=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_71_81','Solid rivets',#5282,$,$); +#5291=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76','Screws',#5029,$,$); +#5292=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_11','Carbon steel hexagon head screws',#5291,$,$); +#5293=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_15','Coach screws',#5291,$,$); +#5294=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_28','Eye lags',#5291,$,$); +#5295=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_50','Machine screws',#5291,$,$); +#5296=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_65','Plasterboard screws',#5291,$,$); +#5297=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_72','Rigging screws',#5291,$,$); +#5298=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_75','Self-tapping screws',#5291,$,$); +#5299=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_76','Self-drilling screws',#5291,$,$); +#5300=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_77','Set screws',#5291,$,$); +#5301=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_78','Sheet metal screws',#5291,$,$); +#5302=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_81','Socket screws',#5291,$,$); +#5303=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_85','Stainless steel hexagon head screws',#5291,$,$); +#5304=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_86','Stainless steel screws',#5291,$,$); +#5305=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_88','Thread-cutting machine screws',#5291,$,$); +#5306=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_76_98','Wood screws',#5291,$,$); +#5307=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_81','Soil nails',#5029,$,$); +#5308=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_81_11','Carbon steel soil nails',#5307,$,$); +#5309=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_81_63','Plastics soil nails',#5307,$,$); +#5310=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_81_84','Stainless steel soil nails',#5307,$,$); +#5311=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_85','Straw bale fixings',#5029,$,$); +#5312=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_85_64','Plastics sleeving',#5311,$,$); +#5313=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_85_65','Polyester straps',#5311,$,$); +#5314=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_87','Thatch roofing fasteners',#5029,$,$); +#5315=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_87_36','Hazel staples',#5314,$,$); +#5316=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_87_37','Hazel sways',#5314,$,$); +#5317=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_87_52','Metal sways',#5314,$,$); +#5318=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_87_87','Thatching hooks',#5314,$,$); +#5319=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_87_96','Willow sways',#5314,$,$); +#5320=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88','Tile and fabric fasteners',#5029,$,$); +#5321=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_26','Edge beading',#5320,$,$); +#5322=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_27','Edge beading rails',#5320,$,$); +#5323=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_31','Forked roofing connectors',#5320,$,$); +#5324=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_37','Hip irons',#5320,$,$); +#5325=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_41','Insulation fixing saddle clips',#5320,$,$); +#5326=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_42','Insulation fixing spikes',#5320,$,$); +#5327=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_43','Insulation fixing straps',#5320,$,$); +#5328=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_59','Overlay fasteners',#5320,$,$); +#5329=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_70','Roofing belts',#5320,$,$); +#5330=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_71','Roofing clamps',#5320,$,$); +#5331=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_72','Roofing clamping plates',#5320,$,$); +#5332=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_73','Roofing corner plates',#5320,$,$); +#5333=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_74','Roofing straps',#5320,$,$); +#5334=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_88_75','Roofing swags',#5320,$,$); +#5335=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_96','Welded joints',#5029,$,$); +#5336=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_96_03','Aluminothermic rail welds',#5335,$,$); +#5337=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_97','Welding joint fillers',#5029,$,$); +#5338=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_97_09','Brazing joint fillers',#5337,$,$); +#5339=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_97_26','Electric welding joint fillers',#5337,$,$); +#5340=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_97_33','Gas welding joint fillers',#5337,$,$); +#5341=IFCCLASSIFICATIONREFERENCE($,'Pr_20_29_97_81','Soldering joint fillers',#5337,$,$); +#5342=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31','Formless structure and general products',#5028,$,$); +#5343=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_01','Additives',#5342,$,$); +#5344=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_01_11','Carbon steel fibres',#5343,$,$); +#5345=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_01_22','Dust suppression additive',#5343,$,$); +#5346=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_01_32','Glass fibres',#5343,$,$); +#5347=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_01_39','Hydraulic road binders',#5343,$,$); +#5348=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_01_75','Polypropylene (PP) fibres',#5343,$,$); +#5349=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_01_85','Stainless steel fibres',#5343,$,$); +#5350=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_01_86','Synthetic fibres',#5343,$,$); +#5351=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_01_96','Waterborne absorption fluids',#5343,$,$); +#5352=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_01_99','Zinc powders',#5343,$,$); +#5353=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02','Adhesives and bonding compounds',#5342,$,$); +#5354=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_02','Acrylic anaerobic adhesives',#5353,$,$); +#5355=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_03','Acrylic and methacrylate adhesives',#5353,$,$); +#5356=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_04','All-purpose pastes',#5353,$,$); +#5357=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_06','Bio-resin adhesives',#5353,$,$); +#5358=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_07','Bitumen bonding compounds',#5353,$,$); +#5359=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_08','Bitumen-based bonding compounds',#5353,$,$); +#5360=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_09','Bitumen rubber emulsion adhesives',#5353,$,$); +#5361=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_11','Casein adhesives',#5353,$,$); +#5362=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_12','Cementitious adhesives',#5353,$,$); +#5363=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_13','Cementitious bonding compounds',#5353,$,$); +#5364=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_15','Cold-applied bitumen bonding compounds',#5353,$,$); +#5365=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_18','Cold water pastes',#5353,$,$); +#5366=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_21','Damp proof course joint sealer adhesives',#5353,$,$); +#5367=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_26','Epoxy resin-based adhesives',#5353,$,$); +#5368=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_28','Epoxy resin-based bonding compounds',#5353,$,$); +#5369=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_29','Epoxy resin ballast glues',#5353,$,$); +#5370=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_35','Gypsum-based adhesives',#5353,$,$); +#5371=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_36','Heavy-duty pastes',#5353,$,$); +#5372=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_37','Hot-applied bitumen bonding compounds',#5353,$,$); +#5373=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_38','High-performance ready-mixed adhesives',#5353,$,$); +#5374=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_50','Masonry injection resins',#5353,$,$); +#5375=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_52','Modified silane (MS) polymer adhesives',#5353,$,$); +#5376=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_56','Natural rubber-based and latex adhesives',#5353,$,$); +#5377=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_57','Non bitumen-based bonding compounds',#5353,$,$); +#5378=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_59','Overlap and border adhesives',#5353,$,$); +#5379=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_60','Parchment size',#5353,$,$); +#5380=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_61','Phenolic, resorcinol and formaldehyde-based resin (PRF) thermosetting adhesives',#5353,$,$); +#5381=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_62','Polyurethane (PUR) adhesives',#5353,$,$); +#5382=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_63','Polyurethane (PUR) ballast reinforcement',#5353,$,$); +#5383=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_64','Polyurethane (PUR) based resin binders',#5353,$,$); +#5384=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_65','Polyvinyl acetate (PVAc) adhesives',#5353,$,$); +#5385=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_66','Polyvinyl acetate (PVAc) bonding compounds',#5353,$,$); +#5386=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_71','Resin binders',#5353,$,$); +#5387=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_76','Sodium silicate binders',#5353,$,$); +#5388=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_80','Solvent-based synthetic rubber resin adhesives',#5353,$,$); +#5389=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_81','Solvent-free cellulose adhesives',#5353,$,$); +#5390=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_82','Solvent-free synthetic rubber resin adhesives',#5353,$,$); +#5391=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_84','Styrene butadiene rubber (SBR) bonding compounds',#5353,$,$); +#5392=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_85','Synthetic bonding compounds',#5353,$,$); +#5393=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_89','Tile adhesives',#5353,$,$); +#5394=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_94','Vermiculite-based adhesives',#5353,$,$); +#5395=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_95','Vinyl adhesives',#5353,$,$); +#5396=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_02_97','Welding paste and solvents',#5353,$,$); +#5397=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03','Admixtures',#5342,$,$); +#5398=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_01','Adherence proofing concrete admixtures',#5397,$,$); +#5399=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_02','Air entraining and plasticizing concrete admixtures',#5397,$,$); +#5400=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_03','Air entraining and plasticizing mortar and screed admixtures',#5397,$,$); +#5401=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_15','Concrete expanding agents',#5397,$,$); +#5402=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_16','Concrete foaming agents',#5397,$,$); +#5403=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_17','Corrosion inhibiting admixtures',#5397,$,$); +#5404=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_31','Frostproofing concrete admixtures',#5397,$,$); +#5405=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_36','Hardening and accelerating concrete admixtures',#5397,$,$); +#5406=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_38','High range water reducing and superplasticizing concrete admixtures',#5397,$,$); +#5407=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_52','Mid-range water reducing and superplasticizing concrete admixtures',#5397,$,$); +#5408=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_58','Oil proofing concrete admixtures',#5397,$,$); +#5409=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_64','Polymer admixtures',#5397,$,$); +#5410=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_76','Set-accelerating concrete admixtures',#5397,$,$); +#5411=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_77','Set-accelerating, water reducing and plasticizing concrete admixtures',#5397,$,$); +#5412=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_78','Set-retarding concrete, mortar and plaster admixtures',#5397,$,$); +#5413=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_79','Set-retarding, high range water reducing and superplasticizing concrete admixtures',#5397,$,$); +#5414=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_80','Set-retarding, water reducing and plasticizing concrete admixtures',#5397,$,$); +#5415=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_84','Sprayed concrete admixtures',#5397,$,$); +#5416=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_94','Viscosity modifying admixtures',#5397,$,$); +#5417=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_95','Waterproofing concrete admixtures',#5397,$,$); +#5418=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_96','Waterproofing mortar admixtures',#5397,$,$); +#5419=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_97','Water-reducing and plasticizing concrete admixtures',#5397,$,$); +#5420=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_03_98','Water-retaining concrete admixtures',#5397,$,$); +#5421=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04','Aggregates',#5342,$,$); +#5422=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_01','Air cooled steel slag',#5421,$,$); +#5423=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_02','All-in normal and heavyweight aggregates',#5421,$,$); +#5424=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_04','Armourstone coarse aggregates',#5421,$,$); +#5425=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_05','Barytes aggregates',#5421,$,$); +#5426=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_06','Base, bed and fill all-in aggregates',#5421,$,$); +#5427=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_07','Base, bed and fill coarse aggregates',#5421,$,$); +#5428=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_08','Base, bed and fill fine aggregates',#5421,$,$); +#5429=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_09','Blinding coarse aggregates',#5421,$,$); +#5430=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_10','Blinding fine aggregates',#5421,$,$); +#5431=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_11','Bonded surfacing decorative aggregates',#5421,$,$); +#5432=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_13','Coarse general aggregates',#5421,$,$); +#5433=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_15','Coarse lightweight aggregates for concrete and mortar',#5421,$,$); +#5434=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_16','Coarse normal and heavyweight aggregates',#5421,$,$); +#5435=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_20','Crushed stone aggregates',#5421,$,$); +#5436=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_25','Expanded clay lightweight aggregates',#5421,$,$); +#5437=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_26','Expanded glass aggregates',#5421,$,$); +#5438=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_27','Expanded slag aggregates',#5421,$,$); +#5439=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_28','Expanded slate aggregates',#5421,$,$); +#5440=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_29','Fine aggregates',#5421,$,$); +#5441=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_30','Fine general aggregates',#5421,$,$); +#5442=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_31','Fine lightweight aggregates for concrete and mortar',#5421,$,$); +#5443=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_32','Fine normal and heavyweight aggregates',#5421,$,$); +#5444=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_35','Granular cork aggregates',#5421,$,$); +#5445=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_42','Iron ore aggregates',#5421,$,$); +#5446=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_44','Jointing fine aggregates',#5421,$,$); +#5447=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_46','Laying course fine aggregates',#5421,$,$); +#5448=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_48','Loose surfacing decorative aggregates',#5421,$,$); +#5449=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_51','Mortar aggregates',#5421,$,$); +#5450=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_52','Mortar coarse aggregates',#5421,$,$); +#5451=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_53','Mortar fine aggregates',#5421,$,$); +#5452=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_56','Natural stone aggregates',#5421,$,$); +#5453=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_57','Natural stone dusts',#5421,$,$); +#5454=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_59','Oyster shells',#5421,$,$); +#5455=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_60','Pea gravel',#5421,$,$); +#5456=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_61','Perlite aggregates',#5421,$,$); +#5457=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_62','Permeable laying course aggregates',#5421,$,$); +#5458=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_71','Recycled lightweight aggregates',#5421,$,$); +#5459=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_72','Recycled rubber granules',#5421,$,$); +#5460=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_77','Scrap iron aggregates',#5421,$,$); +#5461=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_79','Single sized aggregates',#5421,$,$); +#5462=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_80','Soil amelioration aggregates',#5421,$,$); +#5463=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_85','Surface dressing aggregates',#5421,$,$); +#5464=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_86','Surface treatment fine aggregates',#5421,$,$); +#5465=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_04_94','Vermiculite aggregates',#5421,$,$); +#5466=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_12','Cements and limes',#5342,$,$); +#5467=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_12_11','Calcium aluminate cements',#5466,$,$); +#5468=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_12_13','Cement/cement replacement materials',#5466,$,$); +#5469=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_12_38','Hydrated limes',#5466,$,$); +#5470=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_12_39','Hydraulic limes',#5466,$,$); +#5471=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_12_50','Masonry cements',#5466,$,$); +#5472=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_12_57','Non-hydraulic lime putties',#5466,$,$); +#5473=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_12_58','Non-hydraulic limes',#5466,$,$); +#5474=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_12_60','Portland cements',#5466,$,$); +#5475=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_12_69','Quicklime',#5466,$,$); +#5476=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_12_80','Special purpose cements',#5466,$,$); +#5477=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_12_86','Sulfate-resisting Portland cements',#5466,$,$); +#5478=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16','Concretes',#5342,$,$); +#5479=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_12','Cement-bound granular mixtures',#5478,$,$); +#5480=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_21','Designated concrete',#5478,$,$); +#5481=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_22','Designed concrete',#5478,$,$); +#5482=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_29','Fine bedding concretes',#5478,$,$); +#5483=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_30','Fly ash bound mixtures',#5478,$,$); +#5484=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_31','Foamed concrete',#5478,$,$); +#5485=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_37','High strength concrete',#5478,$,$); +#5486=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_39','Hydraulic road binder bound mixtures',#5478,$,$); +#5487=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_56','Normal-class concretes',#5478,$,$); +#5488=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_66','Pre-blended concretes',#5478,$,$); +#5489=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_67','Prescribed concrete',#5478,$,$); +#5490=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_68','Proprietary concretes',#5478,$,$); +#5491=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_70','Resin concretes',#5478,$,$); +#5492=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_72','Roman concretes',#5478,$,$); +#5493=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_76','Self-compacting concretes',#5478,$,$); +#5494=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_78','Slag bound mixtures',#5478,$,$); +#5495=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_80','Small-area repair concretes',#5478,$,$); +#5496=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_82','Special-class performance concretes',#5478,$,$); +#5497=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_83','Special-class prescription concretes',#5478,$,$); +#5498=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_84','Sprayed concretes',#5478,$,$); +#5499=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_85','Standardized prescribed concrete',#5478,$,$); +#5500=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_16_92','Ultra high performance concrete',#5478,$,$); +#5501=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35','Granules and powders',#5342,$,$); +#5502=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_11','Carborundum',#5501,$,$); +#5503=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_22','Diatomaceous earth',#5501,$,$); +#5504=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_30','Fly ash',#5501,$,$); +#5505=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_33','Granulated blast furnace slag',#5501,$,$); +#5506=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_34','Ground granulated blast furnace slag',#5501,$,$); +#5507=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_35','Gypsum',#5501,$,$); +#5508=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_47','Limestone fines',#5501,$,$); +#5509=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_50','Marble dust',#5501,$,$); +#5510=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_51','Metakaolin',#5501,$,$); +#5511=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_52','Microsilica',#5501,$,$); +#5512=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_53','Mineral pigments',#5501,$,$); +#5513=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_56','Natural pozzolan',#5501,$,$); +#5514=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_60','Partially ground granulated blast furnace slag',#5501,$,$); +#5515=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_62','Plaster of Paris',#5501,$,$); +#5516=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_75','Sawdust',#5501,$,$); +#5517=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_81','Silica fume',#5501,$,$); +#5518=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_82','Sintered pulverized fuel ash',#5501,$,$); +#5519=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_35_86','Synthetic foam granules',#5501,$,$); +#5520=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53','Mortars and grouts',#5342,$,$); +#5521=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_08','Brick slip adhesive mortars',#5520,$,$); +#5522=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_10','Cement gauged designed mortars',#5520,$,$); +#5523=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_11','Cement gauged mortars',#5520,$,$); +#5524=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_12','Cementitious and reaction resin grouts',#5520,$,$); +#5525=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_13','Cementitious grouts',#5520,$,$); +#5526=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_14','Cementitious tanking mortars',#5520,$,$); +#5527=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_15','Concrete repair mortars',#5520,$,$); +#5528=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_16','Cementitious tiling grouts',#5520,$,$); +#5529=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_18','Crystallization active slurry mortars',#5520,$,$); +#5530=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_26','Epoxy mortars',#5520,$,$); +#5531=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_27','Epoxy resin grouts',#5520,$,$); +#5532=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_28','Epoxy resin-modified cementitious slurries',#5520,$,$); +#5533=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_30','Fibre-reinforced polymer-modified cementitious mortars',#5520,$,$); +#5534=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_31','Fire-resisting mortars',#5520,$,$); +#5535=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_32','General purpose cement:sand mortars',#5520,$,$); +#5536=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_33','Glass block jointing mortars',#5520,$,$); +#5537=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_34','Glass block pointing mortars',#5520,$,$); +#5538=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_39','Hydraulic lime mortars',#5520,$,$); +#5539=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_40','Injection grouts',#5520,$,$); +#5540=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_41','Injection mortar damp proof courses',#5520,$,$); +#5541=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_42','Injection mortars',#5520,$,$); +#5542=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_43','Intumescent mortars',#5520,$,$); +#5543=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_47','Lightweight masonry mortars',#5520,$,$); +#5544=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_50','Masonry grout',#5520,$,$); +#5545=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_52','Metal anchor and fixings grouts',#5520,$,$); +#5546=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_54','Mortar repair mortar',#5520,$,$); +#5547=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_60','Paving jointing mortars',#5520,$,$); +#5548=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_61','Paving laying course mortars',#5520,$,$); +#5549=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_62','Paving unit priming slurry mortars',#5520,$,$); +#5550=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_64','Polyester resin grouts',#5520,$,$); +#5551=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_65','Polymer-modified cementitious mortars',#5520,$,$); +#5552=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_66','Polymer-modified cementitious slurries',#5520,$,$); +#5553=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_71','Resin grouts',#5520,$,$); +#5554=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_76','Self-hardening slurry mixes',#5520,$,$); +#5555=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_79','Silica grouts',#5520,$,$); +#5556=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_88','Thin-layer mortars',#5520,$,$); +#5557=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_90','Thixotropic resin grouts',#5520,$,$); +#5558=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_53_96','Waterproof mortars',#5520,$,$); +#5559=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_56','Natural resins',#5342,$,$); +#5560=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_56_11','Balsam resins',#5559,$,$); +#5561=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_56_13','Benzoin resins',#5559,$,$); +#5562=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_56_16','Copal resins',#5559,$,$); +#5563=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_56_21','Damar resins',#5559,$,$); +#5564=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_56_46','Lacquer resins',#5559,$,$); +#5565=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_56_50','Mastic resins',#5559,$,$); +#5566=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_56_77','Shellac resins',#5559,$,$); +#5567=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_56_91','Turpentine resins',#5559,$,$); +#5568=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86','Synthetic resins',#5342,$,$); +#5569=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_01','Acetal resins',#5568,$,$); +#5570=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_02','Acrylic resins',#5568,$,$); +#5571=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_03','Acrylonitrile butadiene styrene (ABS) resins',#5568,$,$); +#5572=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_04','Alkyd resins',#5568,$,$); +#5573=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_27','Epoxy resins',#5568,$,$); +#5574=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_28','Ethylene vinyl acetate (EVA) resins',#5568,$,$); +#5575=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_46','Liquid crystal polymer resins',#5568,$,$); +#5576=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_48','Long-fibre reinforced plastics resins',#5568,$,$); +#5577=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_51','Melamine formaldehyde (MF) resins',#5568,$,$); +#5578=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_58','Phenol formaldehyde (PF) resins',#5568,$,$); +#5579=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_59','Polyamide (PA) resins',#5568,$,$); +#5580=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_60','Polycarbonate resins',#5568,$,$); +#5581=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_61','Polyester resins',#5568,$,$); +#5582=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_62','Polyethylene (PE) resins',#5568,$,$); +#5583=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_63','Polyethylene terephthalate (PET) resins',#5568,$,$); +#5584=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_64','Polyphenylene sulfide resins',#5568,$,$); +#5585=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_65','Polypropylene resins',#5568,$,$); +#5586=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_66','Polystyrene (PS) resins',#5568,$,$); +#5587=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_67','Polyurethane (PU) resins',#5568,$,$); +#5588=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_68','Polyvinyl chloride (PVC) resins',#5568,$,$); +#5589=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_77','Silicone resins',#5568,$,$); +#5590=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_88','Thermoplastic elastomer (TPE) resins',#5568,$,$); +#5591=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_92','Unsaturated polyester (UP) resins',#5568,$,$); +#5592=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_93','Urea formaldehyde (UF) resins',#5568,$,$); +#5593=IFCCLASSIFICATIONREFERENCE($,'Pr_20_31_86_94','Vinyl ester resins',#5568,$,$); +#5594=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65','Prefabricated buildings and structures',#5028,$,$); +#5595=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_34','Glazed structures',#5594,$,$); +#5596=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_34_34','Glazed enclosures',#5595,$,$); +#5597=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_34_51','Metal framed structures',#5595,$,$); +#5598=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_34_72','Roof lanterns',#5595,$,$); +#5599=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_50','Modular products',#5594,$,$); +#5600=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_50_10','Bathroom pods',#5599,$,$); +#5601=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_60','Panelled and framed structures',#5594,$,$); +#5602=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_60_15','Concrete panelled buildings',#5601,$,$); +#5603=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_60_17','Cross laminated timber (CLT) panelled buildings',#5601,$,$); +#5604=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_60_47','Light gauge steel floors and roofs',#5601,$,$); +#5605=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_60_48','Light gauge steel frame walls',#5601,$,$); +#5606=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_60_60','Packaged components',#5601,$,$); +#5607=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_60_84','Structural insulated panels (SIPs)',#5601,$,$); +#5608=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_60_88','Timber frame floors and roofs',#5601,$,$); +#5609=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_60_89','Timber frame panels',#5601,$,$); +#5610=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_78','Shelter structures',#5594,$,$); +#5611=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_78_15','Composite panelled shelters',#5610,$,$); +#5612=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_78_34','Glazed shelters',#5610,$,$); +#5613=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_78_58','Open sided shelters',#5610,$,$); +#5614=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_78_77','Semi closed shelters',#5610,$,$); +#5615=IFCCLASSIFICATIONREFERENCE($,'Pr_20_65_78_88','Timber framed and panelled shelters',#5610,$,$); +#5616=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76','Sectional products',#5028,$,$); +#5617=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_06','Balusters and newel posts',#5616,$,$); +#5618=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_06_03','Aluminium balusters and newel posts',#5617,$,$); +#5619=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_06_11','Carbon steel balusters and newel posts',#5617,$,$); +#5620=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_06_12','Cast iron balusters and newel posts',#5617,$,$); +#5621=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_06_16','Concrete balusters and newel posts',#5617,$,$); +#5622=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_06_36','Hardwood balusters and newel posts',#5617,$,$); +#5623=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_06_63','Plastics balusters and newel posts',#5617,$,$); +#5624=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_06_80','Softwood balusters and newel posts',#5617,$,$); +#5625=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_06_83','Stainless steel balusters and newel posts',#5617,$,$); +#5626=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_06_86','Stone balusters and newel posts',#5617,$,$); +#5627=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_06_88','Timber spindles',#5617,$,$); +#5628=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08','Bollards and impact protectors',#5616,$,$); +#5629=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_02','Aluminium alloy bollards',#5628,$,$); +#5630=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_03','Aluminium alloy hinged bollards',#5628,$,$); +#5631=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_04','Aluminium alloy telescopic bollards',#5628,$,$); +#5632=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_10','Carbon steel bollards',#5628,$,$); +#5633=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_11','Carbon steel hinged bollards',#5628,$,$); +#5634=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_12','Carbon steel rising bollards',#5628,$,$); +#5635=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_13','Carbon steel telescopic bollards',#5628,$,$); +#5636=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_14','Cast iron bollards',#5628,$,$); +#5637=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_15','Collapsible metal bollards',#5628,$,$); +#5638=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_16','Collapsible polymer bollards',#5628,$,$); +#5639=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_17','Collapsible timber bollards',#5628,$,$); +#5640=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_18','Composite bollards',#5628,$,$); +#5641=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_19','Concrete bollards',#5628,$,$); +#5642=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_36','Hardwood bollards',#5628,$,$); +#5643=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_51','Metal bollards',#5628,$,$); +#5644=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_52','Metal impact protectors',#5628,$,$); +#5645=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_53','Metal impact protectors with infill',#5628,$,$); +#5646=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_60','Panel fenders',#5628,$,$); +#5647=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_62','Plastics bollards',#5628,$,$); +#5648=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_63','Plastics hinged car bollards',#5628,$,$); +#5649=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_64','Plastics rising bollards',#5628,$,$); +#5650=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_65','Plastics telescopic bollards',#5628,$,$); +#5651=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_66','Polymer bollards',#5628,$,$); +#5652=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_67','Precast concrete bollards',#5628,$,$); +#5653=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_71','Retracting metal bollards',#5628,$,$); +#5654=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_82','Stainless steel bollards',#5628,$,$); +#5655=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_83','Stainless steel hinged bollards',#5628,$,$); +#5656=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_84','Stainless steel rising bollards',#5628,$,$); +#5657=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_85','Stainless steel telescopic bollards',#5628,$,$); +#5658=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_86','Stone bollards',#5628,$,$); +#5659=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_08_88','Timber bollards',#5628,$,$); +#5660=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51','Metal sections',#5616,$,$); +#5661=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_01','Aluminium cold drawn bars and rods',#5660,$,$); +#5662=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_02','Aluminium curtain wall frame sections',#5660,$,$); +#5663=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_03','Aluminium extruded bars and rods',#5660,$,$); +#5664=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_04','Aluminium extruded precision profiles',#5660,$,$); +#5665=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_05','Aluminium patent glazing bars',#5660,$,$); +#5666=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_07','Aluminium structural sections',#5660,$,$); +#5667=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_08','Box sections',#5660,$,$); +#5668=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_09','Brass sections',#5660,$,$); +#5669=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_10','Bronze sections',#5660,$,$); +#5670=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_11','Carbon steel bars',#5660,$,$); +#5671=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_12','Carbon steel beams, columns, channels and tees',#5660,$,$); +#5672=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_13','Carbon steel channels',#5660,$,$); +#5673=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_14','Carbon steel curtain wall frame sections',#5660,$,$); +#5674=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_15','Carbon steel curved sections',#5660,$,$); +#5675=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_17','Carbon steel pales',#5660,$,$); +#5676=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_18','Carbon steel patent glazing bars',#5660,$,$); +#5677=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_19','Carbon steel tees',#5660,$,$); +#5678=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_20','Cast iron products',#5660,$,$); +#5679=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_21','Cold-formed galvanized steel sections',#5660,$,$); +#5680=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_22','Cold-formed steel strip studs',#5660,$,$); +#5681=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_23','Copper alloy sections',#5660,$,$); +#5682=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_25','Curtain wall blast-resistant frame sections',#5660,$,$); +#5683=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_51','Metal mullions and transoms',#5660,$,$); +#5684=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_73','Resilient bars',#5660,$,$); +#5685=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_77','Sheathed carbon steel patent glazing bars',#5660,$,$); +#5686=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_81','Stainless steel bars and rods for construction',#5660,$,$); +#5687=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_82','Stainless steel bars and rods for general purposes',#5660,$,$); +#5688=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_83','Stainless steel sheet, strip and plate for construction',#5660,$,$); +#5689=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_84','Stainless steel sheet, strip and plate for general purposes',#5660,$,$); +#5690=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_85','Stainless steel pales',#5660,$,$); +#5691=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_90','Universal beam sections',#5660,$,$); +#5692=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_92','Universal column sections',#5660,$,$); +#5693=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_51_98','Wrought iron sections',#5660,$,$); +#5694=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_52','Metal tubes and hollow sections',#5616,$,$); +#5695=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_52_01','Aluminium cold drawn tubes',#5694,$,$); +#5696=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_52_03','Aluminium extruded tubes',#5694,$,$); +#5697=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_52_16','Carbon steel hot-finished hollow sections',#5694,$,$); +#5698=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_52_19','Carbon steel seamless tubes',#5694,$,$); +#5699=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_52_20','Carbon steel welded tubes',#5694,$,$); +#5700=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_52_85','Stainless steel seamless circular tubes',#5694,$,$); +#5701=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_52_86','Stainless steel welded circular tubes',#5694,$,$); +#5702=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_63','Plastics sections',#5616,$,$); +#5703=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_63_30','Flexible foam rods',#5702,$,$); +#5704=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_63_63','Plastics mullions and transoms',#5702,$,$); +#5705=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_63_65','Plastics palisades',#5702,$,$); +#5706=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_63_85','Structural plastics sections',#5702,$,$); +#5707=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_63_92','Unplasticized polyvinyl chloride (PVC-U) curtain wall frame sections',#5702,$,$); +#5708=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64','Posts and post accessories',#5616,$,$); +#5709=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_01','Adjustable post bases',#5708,$,$); +#5710=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_03','Aluminium alloy posts',#5708,$,$); +#5711=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_04','Aluminium post tops',#5708,$,$); +#5712=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_10','Carbon steel electric security fencing posts',#5708,$,$); +#5713=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_11','Carbon steel extension arms',#5708,$,$); +#5714=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_12','Carbon steel posts',#5708,$,$); +#5715=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_13','Carbon steel post tops',#5708,$,$); +#5716=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_14','Carbon steel wind posts',#5708,$,$); +#5717=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_15','Cast iron posts',#5708,$,$); +#5718=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_16','Cast iron post tops',#5708,$,$); +#5719=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_17','Cast stone or concrete posts',#5708,$,$); +#5720=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_18','Cast stone or concrete post tops',#5708,$,$); +#5721=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_19','Concrete extension arms',#5708,$,$); +#5722=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_20','Concrete posts',#5708,$,$); +#5723=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_21','Concrete post tops',#5708,$,$); +#5724=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_36','Hardwood posts',#5708,$,$); +#5725=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_37','Hardwood post tops',#5708,$,$); +#5726=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_51','Metal electric security fencing posts',#5708,$,$); +#5727=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_52','Metal extension arms',#5708,$,$); +#5728=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_53','Metal posts',#5708,$,$); +#5729=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_54','Metal post bases',#5708,$,$); +#5730=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_55','Metal post tops',#5708,$,$); +#5731=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_62','Plastics posts',#5708,$,$); +#5732=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_63','Plastics post tops',#5708,$,$); +#5733=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_65','Polymer posts',#5708,$,$); +#5734=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_66','Polymer post tops',#5708,$,$); +#5735=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_77','Softwood posts',#5708,$,$); +#5736=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_78','Softwood post tops',#5708,$,$); +#5737=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_80','Stainless steel posts',#5708,$,$); +#5738=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_81','Stainless steel post tops',#5708,$,$); +#5739=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_82','Stainless steel wind posts',#5708,$,$); +#5740=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_83','Stand-off post bases',#5708,$,$); +#5741=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_87','Timber hand posts',#5708,$,$); +#5742=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_88','Timber posts',#5708,$,$); +#5743=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_89','Timber post tops',#5708,$,$); +#5744=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_95','Wood hand posts',#5708,$,$); +#5745=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_64_96','Wood panel supports',#5708,$,$); +#5746=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70','Rail track and ancillaries',#5616,$,$); +#5747=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_09','Bullhead rails',#5746,$,$); +#5748=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_12','Check rails',#5746,$,$); +#5749=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_15','Conductor rails',#5746,$,$); +#5750=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_22','Derailment containment',#5746,$,$); +#5751=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_27','Equipment protection ramps',#5746,$,$); +#5752=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_28','Expansion switches and adjustment switches',#5746,$,$); +#5753=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_30','Flat bottom rails',#5746,$,$); +#5754=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_34','Grooved rails',#5746,$,$); +#5755=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_60','Particle magnets',#5746,$,$); +#5756=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_67','Rail dampers',#5746,$,$); +#5757=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_69','Rail groove drains',#5746,$,$); +#5758=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_70','Rail track tie bars',#5746,$,$); +#5759=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_71','Rail section convertors',#5746,$,$); +#5760=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_80','Slipper runs',#5746,$,$); +#5761=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_70_90','Transition rails',#5746,$,$); +#5762=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71','Railway junction works',#5616,$,$); +#5763=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_15','Common crossings',#5762,$,$); +#5764=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_17','Crossovers',#5762,$,$); +#5765=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_21','Derailers',#5762,$,$); +#5766=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_23','Diamond crossings',#5762,$,$); +#5767=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_50','Moveable rail crossings',#5762,$,$); +#5768=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_58','Obtuse crossings',#5762,$,$); +#5769=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_76','Scissor crossovers',#5762,$,$); +#5770=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_78','Slips',#5762,$,$); +#5771=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_79','Switch rollers',#5762,$,$); +#5772=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_80','Stretcher bars',#5762,$,$); +#5773=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_81','Stretcher bar brackets',#5762,$,$); +#5774=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_82','Stretcher drive brackets',#5762,$,$); +#5775=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_83','Swing nose crossings',#5762,$,$); +#5776=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_84','Switch and stock rails',#5762,$,$); +#5777=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_85','Switch diamonds',#5762,$,$); +#5778=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_86','Switch supplementary drives',#5762,$,$); +#5779=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_87','Tandem turnouts',#5762,$,$); +#5780=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_90','Trap switches',#5762,$,$); +#5781=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_71_91','Turnouts',#5762,$,$); +#5782=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_78','Shaft structure products',#5616,$,$); +#5783=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_78_12','Concrete caisson rings',#5782,$,$); +#5784=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_78_14','Concrete shaft cover slabs',#5782,$,$); +#5785=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_78_16','Concrete shaft landing slabs',#5782,$,$); +#5786=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_78_65','Precast concrete shaft units',#5782,$,$); +#5787=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88','Timber sections',#5616,$,$); +#5788=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_14','Cleft chestnut pales',#5787,$,$); +#5789=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_32','Hardwood capping and counter fencing rails',#5787,$,$); +#5790=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_33','Hardwood components for fencing and barriers',#5787,$,$); +#5791=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_34','Hardwood fencing rails',#5787,$,$); +#5792=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_35','Hardwood floating floor battens',#5787,$,$); +#5793=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_36','Hardwood gravity battens',#5787,$,$); +#5794=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_37','Hardwood log poles',#5787,$,$); +#5795=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_40','Hardwood pales',#5787,$,$); +#5796=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_41','Hardwood partition studs',#5787,$,$); +#5797=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_42','Hardwood rafters',#5787,$,$); +#5798=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_43','Hardwood roofing and cladding battens',#5787,$,$); +#5799=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_44','Hardwood sections',#5787,$,$); +#5800=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_46','Hardwood weatherboarding battens',#5787,$,$); +#5801=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_48','Laminated strand lumber (LSL) sections',#5787,$,$); +#5802=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_49','Laminated veneer lumber (LVL) sections',#5787,$,$); +#5803=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_60','Parallel strand lumber (PSL) sections',#5787,$,$); +#5804=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_72','Softwood capping and counter fencing rails',#5787,$,$); +#5805=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_73','Softwood components for fencing and barriers',#5787,$,$); +#5806=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_74','Softwood fencing rails',#5787,$,$); +#5807=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_75','Softwood floating floor battens',#5787,$,$); +#5808=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_76','Softwood gravity battens',#5787,$,$); +#5809=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_79','Softwood pales',#5787,$,$); +#5810=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_80','Softwood partition studs',#5787,$,$); +#5811=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_81','Softwood rafters',#5787,$,$); +#5812=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_82','Softwood roofing and cladding battens',#5787,$,$); +#5813=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_83','Softwood sections',#5787,$,$); +#5814=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_84','Softwood weatherboarding battens',#5787,$,$); +#5815=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_85','Timber beams, bearers, noggings, walings, wedges and packs',#5787,$,$); +#5816=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_86','Timber fencing battens',#5787,$,$); +#5817=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_87','Timber partition battens',#5787,$,$); +#5818=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_88','Timber pales',#5787,$,$); +#5819=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_88_89','Timber mullions and transoms',#5787,$,$); +#5820=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_92','Tunnel structure products',#5616,$,$); +#5821=IFCCLASSIFICATIONREFERENCE($,'Pr_20_76_92_65','Precast concrete tunnel units',#5820,$,$); +#5822=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85','Support and restraint products',#5028,$,$); +#5823=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_03','Angles',#5822,$,$); +#5824=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_03_02','Aluminium angles',#5823,$,$); +#5825=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_03_11','Carbon steel angle sections',#5823,$,$); +#5826=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_03_50','Masonry angle supports',#5823,$,$); +#5827=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_03_63','Plain angle supports',#5823,$,$); +#5828=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_03_84','Stainless steel angles',#5823,$,$); +#5829=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_03_85','Stainless steel cladding angles',#5823,$,$); +#5830=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_06','Bands and hoops',#5822,$,$); +#5831=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_06_06','Bandings',#5830,$,$); +#5832=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_06_11','Carbon steel hoops',#5830,$,$); +#5833=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_06_85','Stainless steel hoops',#5830,$,$); +#5834=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07','Barrier rails',#5822,$,$); +#5835=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_02','Aluminium alloy rails',#5834,$,$); +#5836=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_03','Aluminium support rails',#5834,$,$); +#5837=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_04','Aluminium carrier rails',#5834,$,$); +#5838=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_10','Carbon steel carrier rails',#5834,$,$); +#5839=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_11','Carbon steel fencing and barrier rails',#5834,$,$); +#5840=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_12','Carbon steel fencing and barrier top rails',#5834,$,$); +#5841=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_13','Carbon steel safety barrier open box beams',#5834,$,$); +#5842=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_14','Carbon steel safety barrier rectangular hollow sections',#5834,$,$); +#5843=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_15','Carbon steel safety barrier tensioned corrugated beams',#5834,$,$); +#5844=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_16','Carbon steel safety barrier transitions and connections',#5834,$,$); +#5845=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_17','Carbon steel safety barrier un-tensioned corrugated beams',#5834,$,$); +#5846=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_18','Carbon steel support rails',#5834,$,$); +#5847=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_19','Cast iron rails',#5834,$,$); +#5848=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_20','Concrete rails',#5834,$,$); +#5849=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_63','Plastics rails',#5834,$,$); +#5850=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_65','Protective frames',#5834,$,$); +#5851=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_83','Stainless steel carrier rails',#5834,$,$); +#5852=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_84','Stainless steel rails',#5834,$,$); +#5853=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_85','Stainless steel support rails',#5834,$,$); +#5854=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_92','Unplasticized polyvinyl chloride (PVC-U) support rails',#5834,$,$); +#5855=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_07_97','Wall-mounted furniture support rails',#5834,$,$); +#5856=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08','Beams and joists',#5822,$,$); +#5857=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_02','Aluminium structural beams',#5856,$,$); +#5858=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_11','Carbon steel beams',#5856,$,$); +#5859=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_12','Castellated carbon steel beams',#5856,$,$); +#5860=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_15','Concrete beams',#5856,$,$); +#5861=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_17','Cross laminated timber beams',#5856,$,$); +#5862=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_33','Glued laminated timber beams',#5856,$,$); +#5863=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_36','Hardwood beams',#5856,$,$); +#5864=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_63','Plastics beams',#5856,$,$); +#5865=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_65','Post-tensioned concrete beams',#5856,$,$); +#5866=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_66','Prestressed concrete T-beams',#5856,$,$); +#5867=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_81','Softwood beams',#5856,$,$); +#5868=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_83','Stainless steel structural beams',#5856,$,$); +#5869=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_84','Structural wood-composite box beams',#5856,$,$); +#5870=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_85','Structural wood-composite I-beams',#5856,$,$); +#5871=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_86','Structural wood-composite I-joists',#5856,$,$); +#5872=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_08_87','Structural wood composites',#5856,$,$); +#5873=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09','Brackets',#5822,$,$); +#5874=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_01','Above-ground drainage pipe brackets',#5873,$,$); +#5875=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_02','Aluminium brackets',#5873,$,$); +#5876=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_03','Aluminium bronze brackets',#5873,$,$); +#5877=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_05','Aluminium downpipe brackets',#5873,$,$); +#5878=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_07','Aluminium rainwater gutter brackets',#5873,$,$); +#5879=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_09','Bracketed angle supports',#5873,$,$); +#5880=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_11','Carbon steel brackets',#5873,$,$); +#5881=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_12','Carbon steel cavity barrier brackets',#5873,$,$); +#5882=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_14','Carbon steel fencing brackets',#5873,$,$); +#5883=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_16','Carbon steel masonry brackets',#5873,$,$); +#5884=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_17','Cast and wrought iron brackets',#5873,$,$); +#5885=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_18','Cast iron downpipe brackets',#5873,$,$); +#5886=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_19','Cast iron rainwater gutter brackets',#5873,$,$); +#5887=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_20','Copper brackets',#5873,$,$); +#5888=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_21','Copper downpipe brackets',#5873,$,$); +#5889=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_22','Copper rainwater gutter brackets',#5873,$,$); +#5890=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_23','Curtain wall adjustable support brackets',#5873,$,$); +#5891=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_24','Downpipe brackets',#5873,$,$); +#5892=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_26','Eaves gutter brackets',#5873,$,$); +#5893=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_28','Extinguisher mounting brackets',#5873,$,$); +#5894=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_30','Fire bucket wall brackets',#5873,$,$); +#5895=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_31','Galvanized steel downpipe brackets',#5873,$,$); +#5896=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_32','Galvanized steel rainwater gutter brackets',#5873,$,$); +#5897=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_33','Galvanized steel brackets',#5873,$,$); +#5898=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_37','Hollow box galvanized steel brackets',#5873,$,$); +#5899=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_38','Hot-dip pre-coated carbon steel downpipe brackets',#5873,$,$); +#5900=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_39','Hot-dip pre-coated carbon steel rainwater gutter brackets',#5873,$,$); +#5901=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_42','Individual masonry brackets',#5873,$,$); +#5902=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_46','Ladder gutter brackets',#5873,$,$); +#5903=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_47','Ladder wall brackets',#5873,$,$); +#5904=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_48','Louvre and shading mounting brackets',#5873,$,$); +#5905=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_52','Metal timber member fixing brackets',#5873,$,$); +#5906=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_54','Mounting brackets',#5873,$,$); +#5907=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_62','Phosphor bronze brackets',#5873,$,$); +#5908=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_63','Plastics brackets',#5873,$,$); +#5909=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_72','Roof gutter brackets',#5873,$,$); +#5910=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_81','Stainless steel brackets',#5873,$,$); +#5911=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_82','Stainless steel cavity barrier brackets',#5873,$,$); +#5912=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_84','Stainless steel handrail brackets',#5873,$,$); +#5913=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_87','Stainless steel masonry brackets',#5873,$,$); +#5914=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_88','Sink supports',#5873,$,$); +#5915=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_92','Unplasticized polyvinyl chloride (PVC-U) downpipe brackets',#5873,$,$); +#5916=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_93','Unplasticized polyvinyl chloride (PVC-U) rainwater gutter brackets',#5873,$,$); +#5917=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_96','Wall-hung WC support brackets',#5873,$,$); +#5918=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_09_98','Wash basin support brackets',#5873,$,$); +#5919=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_10','Bridge bearings',#5822,$,$); +#5920=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_10_20','Cylindrical PTFE bearings',#5919,$,$); +#5921=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_10_27','Elastomeric bearings',#5919,$,$); +#5922=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_10_35','Guide bearings',#5919,$,$); +#5923=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_10_65','Pot bearings',#5919,$,$); +#5924=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_10_70','Restraint bearings',#5919,$,$); +#5925=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_10_72','Rocker bearings',#5919,$,$); +#5926=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_10_73','Roller bearings',#5919,$,$); +#5927=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_10_79','Sliding element',#5919,$,$); +#5928=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_10_81','Spherical PTFE bearings',#5919,$,$); +#5929=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_11','Bridge suspension cables',#5822,$,$); +#5930=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_11_48','Locked coil strand cables',#5929,$,$); +#5931=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_11_60','Parallel wire strand cables',#5929,$,$); +#5932=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_11_80','Spiral strand cables',#5929,$,$); +#5933=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_12','Bunds and ducts',#5822,$,$); +#5934=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_12_14','Concrete bund units',#5933,$,$); +#5935=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_12_24','Concrete duct units',#5933,$,$); +#5936=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_13','Concrete base and foundation products',#5822,$,$); +#5937=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_13_29','Concrete bases for fence posts',#5936,$,$); +#5938=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_13_30','Concrete floating slab foundations',#5936,$,$); +#5939=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_13_32','Concrete foundation pads',#5936,$,$); +#5940=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_13_35','Concrete ground beams',#5936,$,$); +#5941=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_13_63','Concrete plinth units',#5936,$,$); +#5942=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_13_65','Concrete pocket foundations',#5936,$,$); +#5943=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_14','Concrete flooring and decking products',#5822,$,$); +#5944=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_14_14','Concrete hollow core slabs',#5943,$,$); +#5945=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_14_15','Concrete kentledge blocks',#5943,$,$); +#5946=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_14_16','Concrete solid slabs',#5943,$,$); +#5947=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_16','Columns and column accessories',#5822,$,$); +#5948=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_16_02','Aluminium structural columns',#5947,$,$); +#5949=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_16_03','Aluminium column shoes',#5947,$,$); +#5950=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_16_11','Carbon steel columns',#5947,$,$); +#5951=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_16_12','Carbon steel column shoes',#5947,$,$); +#5952=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_16_15','Concrete columns',#5947,$,$); +#5953=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_16_36','Hardwood structural columns',#5947,$,$); +#5954=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_16_62','Plastics columns',#5947,$,$); +#5955=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_16_81','Softwood structural columns',#5947,$,$); +#5956=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_16_84','Stainless steel structural columns',#5947,$,$); +#5957=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_16_85','Stainless steel column shoes',#5947,$,$); +#5958=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_16_86','Stone columns',#5947,$,$); +#5959=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_16_96','Wind posts',#5947,$,$); +#5960=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_18','Bridge deck products',#5822,$,$); +#5961=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_18_10','Bridge diaphragms',#5960,$,$); +#5962=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_18_12','Cast iron bridge pedestals',#5960,$,$); +#5963=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_18_14','Concrete bridge pedestals',#5960,$,$); +#5964=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_18_85','Steel bridge pedestals',#5960,$,$); +#5965=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28','Erosion control and breakwater products',#5822,$,$); +#5966=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_09','Brushwood fascines',#5965,$,$); +#5967=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_15','Coir erosion mats',#5965,$,$); +#5968=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_16','Concrete tetrapods',#5965,$,$); +#5969=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_27','Erosion control logs',#5965,$,$); +#5970=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_28','Erosion control pallets',#5965,$,$); +#5971=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_30','Flood barriers',#5965,$,$); +#5972=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_33','Galvanized wire bastion cages',#5965,$,$); +#5973=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_34','Galvanized wire mattress cages',#5965,$,$); +#5974=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_35','Galvanized wire trapion cages',#5965,$,$); +#5975=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_36','Galvanized wire gabion cages',#5965,$,$); +#5976=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_38','Hessian bags',#5965,$,$); +#5977=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_45','Liquid-absorbing barriers',#5965,$,$); +#5978=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_46','Liquid-absorbing sacks',#5965,$,$); +#5979=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_62','Plastics mattress cages',#5965,$,$); +#5980=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_63','Polypropylene bags',#5965,$,$); +#5981=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_64','Polypropylene (PP) rock rolls',#5965,$,$); +#5982=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_28_75','Sand bags',#5965,$,$); +#5983=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32','Frames and grids',#5822,$,$); +#5984=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_01','Aluminium-zinc coated retention grids',#5983,$,$); +#5985=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_02','Aluminium frames',#5983,$,$); +#5986=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_04','Aluminium structural sealant glazing sub-frames',#5983,$,$); +#5987=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_06','Aluminium sub-frames',#5983,$,$); +#5988=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_11','Carbon steel frames',#5983,$,$); +#5989=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_12','Carbon steel frame fasteners',#5983,$,$); +#5990=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_13','Carbon steel structural sealant glazing sub-frames',#5983,$,$); +#5991=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_14','Carbon steel dry lining frames',#5983,$,$); +#5992=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_16','Carbon steel sub-frames',#5983,$,$); +#5993=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_22','Demountable suspended ceiling grids',#5983,$,$); +#5994=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_30','Floor level chute support frames',#5983,$,$); +#5995=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_80','Solar module ballasted mounting frames',#5983,$,$); +#5996=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_81','Solar module free-standing mounting frames',#5983,$,$); +#5997=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_82','Space frames',#5983,$,$); +#5998=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_84','Stainless steel frames',#5983,$,$); +#5999=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_85','Stainless steel frame fasteners',#5983,$,$); +#6000=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_88','Timber dry lining frames',#5983,$,$); +#6001=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_92','Unplasticized polyvinyl chloride (PVC-U) frames',#5983,$,$); +#6002=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_93','Unplasticized polyvinyl chloride (PVC-U) sub-frames',#5983,$,$); +#6003=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_94','Unplasticized polyvinyl chloride (PVC-U) window sub-frames',#5983,$,$); +#6004=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_96','Wood frames',#5983,$,$); +#6005=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_97','Wood sub-frames',#5983,$,$); +#6006=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_32_98','Wood window sub-frames',#5983,$,$); +#6007=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_34','Ground support products',#5822,$,$); +#6008=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_34_34','Grouted pipe spiles',#6007,$,$); +#6009=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_34_84','Steel spiles',#6007,$,$); +#6010=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_46','Lathings and furrings',#5822,$,$); +#6011=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_46_21','Damp proof lathings',#6010,$,$); +#6012=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_46_28','Expanded metal lathings',#6010,$,$); +#6013=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_46_36','Hardwood furrings',#6010,$,$); +#6014=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_46_52','Metal arch form lathings',#6010,$,$); +#6015=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_46_53','Metal furring channels',#6010,$,$); +#6016=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_46_96','Wood lathings',#6010,$,$); +#6017=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_46_97','Wood tapered furring pieces',#6010,$,$); +#6018=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_47','Legs, pedestals, hangers and stringers',#5822,$,$); +#6019=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_47_01','Access floor bridging sections',#6018,$,$); +#6020=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_47_02','Access floor pedestals',#6018,$,$); +#6021=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_47_03','Access floor stringers',#6018,$,$); +#6022=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_47_04','Acoustic batten cradles',#6018,$,$); +#6023=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_47_20','Cubicle and partition legs',#6018,$,$); +#6024=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_47_22','Decking and paving pedestals',#6018,$,$); +#6025=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_47_47','Leg supports',#6018,$,$); +#6026=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_47_49','Metal J hangers',#6018,$,$); +#6027=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_47_50','Metal hanging rails',#6018,$,$); +#6028=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_47_51','Metal suspended ceiling hangers',#6018,$,$); +#6029=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_47_84','Stair stringers',#6018,$,$); +#6030=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_47_88','Timber dowel hanging rails',#6018,$,$); +#6031=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_48','Lintels',#5822,$,$); +#6032=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_48_02','Aggregate concrete trough lintels',#6031,$,$); +#6033=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_48_11','Carbon steel lintels',#6031,$,$); +#6034=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_48_13','Clay block trough lintels',#6031,$,$); +#6035=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_48_15','Concrete lintels',#6031,$,$); +#6036=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_48_33','Glass-reinforced concrete (GRC) built-in lintel heads',#6031,$,$); +#6037=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_48_34','Glass-reinforced concrete (GRC) dressing lintel heads',#6031,$,$); +#6038=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_48_43','Inset open fireplace throat-forming lintels and corbel units',#6031,$,$); +#6039=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_48_50','Manufactured stone lintels',#6031,$,$); +#6040=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_48_56','Natural stone lintels',#6031,$,$); +#6041=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_48_67','Prestressed concrete lintels',#6031,$,$); +#6042=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_48_84','Stainless steel lintels',#6031,$,$); +#6043=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_48_88','Timber lintels',#6031,$,$); +#6044=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_50','Masts and poles',#5822,$,$); +#6045=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_50_01','Aeronautical ground lighting masts',#6044,$,$); +#6046=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_50_04','Antenna poles',#6044,$,$); +#6047=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_50_50','Metal windsock masts',#6044,$,$); +#6048=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_50_64','Plastics windsock masts',#6044,$,$); +#6049=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_50_85','Surveillance camera masts',#6044,$,$); +#6050=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_50_90','Traffic signal poles',#6044,$,$); +#6051=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62','Piles and ancillary products',#5822,$,$); +#6052=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_10','Carbon steel displacement piles',#6051,$,$); +#6053=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_11','Carbon steel pile casings',#6051,$,$); +#6054=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_12','Carbon steel pile shoes',#6051,$,$); +#6055=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_13','Carbon steel screw piles',#6051,$,$); +#6056=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_14','Carbon steel sheet piles',#6051,$,$); +#6057=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_15','Cast steel pile shoes',#6051,$,$); +#6058=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_16','Composite steel sheet piles',#6051,$,$); +#6059=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_17','Concrete cantilevered knuckle piles',#6051,$,$); +#6060=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_18','Concrete piles',#6051,$,$); +#6061=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_19','Concrete pile caps',#6051,$,$); +#6062=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_23','Concrete sheet piles',#6051,$,$); +#6063=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_36','Hardwood piles',#6051,$,$); +#6064=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_64','Plastics drainage weep holes',#6051,$,$); +#6065=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_65','Plastics screw piles',#6051,$,$); +#6066=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_66','Plastics sheet piles',#6051,$,$); +#6067=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_77','Sheet pile wall corner connectors',#6051,$,$); +#6068=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_62_80','Softwood piles',#6051,$,$); +#6069=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_65','Platform products',#5822,$,$); +#6070=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_65_11','Concrete platform copings',#6069,$,$); +#6071=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_65_13','Concrete platform sections',#6069,$,$); +#6072=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_65_15','Concrete platform slabs',#6069,$,$); +#6073=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_65_17','Concrete platform units',#6069,$,$); +#6074=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_65_34','Glass reinforced plastics (GRP) modular platform panel',#6069,$,$); +#6075=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70','Rail supports and fixings',#5822,$,$); +#6076=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_08','Bullhead rail chairs',#6075,$,$); +#6077=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_10','Cast blocks and spacers assemblies',#6075,$,$); +#6078=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_12','Check rail baseplates',#6075,$,$); +#6079=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_13','Check rail resilient baseplates',#6075,$,$); +#6080=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_24','Driven spikes',#6075,$,$); +#6081=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_30','Ferrules and bushes',#6075,$,$); +#6082=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_44','Junction work baseplates',#6075,$,$); +#6083=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_45','Junction work crossing plates',#6075,$,$); +#6084=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_46','Junction work heel baseplates',#6075,$,$); +#6085=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_47','Junction work resilient baseplates',#6075,$,$); +#6086=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_48','Junction work resilient slide plates',#6075,$,$); +#6087=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_49','Junction work slide plates',#6075,$,$); +#6088=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_54','Metal spacers assemblies',#6075,$,$); +#6089=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_63','Plain line resilient baseplates',#6075,$,$); +#6090=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_64','Plain line baseplates',#6075,$,$); +#6091=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_65','Plastics rail embedments',#6075,$,$); +#6092=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_70','Rail boots',#6075,$,$); +#6093=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_71','Rail clip and shoulder assemblies',#6075,$,$); +#6094=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_74','Rubber chamber filling elements',#6075,$,$); +#6095=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_76','Screw spikes',#6075,$,$); +#6096=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_80','Soleplates',#6075,$,$); +#6097=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_70_82','Spring spikes',#6075,$,$); +#6098=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_71','Rail rings',#5822,$,$); +#6099=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_71_11','Carbon steel rings',#6098,$,$); +#6100=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_71_12','Cast iron bolted rings',#6098,$,$); +#6101=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_71_13','Cast iron expanded rings',#6098,$,$); +#6102=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_71_15','Concrete bolted rings',#6098,$,$); +#6103=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_71_16','Concrete expanded rings',#6098,$,$); +#6104=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_71_57','Nodular iron rings',#6098,$,$); +#6105=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_72','Rail sleepers and bearers',#5822,$,$); +#6106=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_72_17','Composite bearers',#6105,$,$); +#6107=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_72_18','Composite sleepers',#6105,$,$); +#6108=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_72_20','Concrete bearers',#6105,$,$); +#6109=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_72_21','Concrete monoblock sleepers',#6105,$,$); +#6110=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_72_22','Concrete twinblock sleepers',#6105,$,$); +#6111=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_72_47','Longitudinal bearers',#6105,$,$); +#6112=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_72_50','Modular bearer tie plates',#6105,$,$); +#6113=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_72_77','Single block rail support',#6105,$,$); +#6114=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_72_80','Sleeper anchors',#6105,$,$); +#6115=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_72_85','Steel sleepers',#6105,$,$); +#6116=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_72_88','Timber bearers',#6105,$,$); +#6117=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_72_89','Timber sleepers',#6105,$,$); +#6118=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_74','Rail pads and shims',#5822,$,$); +#6119=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_74_06','Baseplate shims',#6118,$,$); +#6120=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_74_27','Ethyl vinyl acetate rail pads',#6118,$,$); +#6121=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_74_70','Rail packing shims',#6118,$,$); +#6122=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_74_71','Rail pads',#6118,$,$); +#6123=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_74_73','Resilient baseplate pads',#6118,$,$); +#6124=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_74_74','Resilient bearer pads',#6118,$,$); +#6125=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_74_76','Resilient sleeper pads',#6118,$,$); +#6126=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_74_78','Rubber bonded cork rail pads',#6118,$,$); +#6127=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_74_79','Rubber rail pads',#6118,$,$); +#6128=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_76','Shock absorbers',#5822,$,$); +#6129=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_76_09','Bridge shock absorbers',#6128,$,$); +#6130=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_76_76','Seismic dampers',#6128,$,$); +#6131=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84','Straps, ties, channels and inserts',#5822,$,$); +#6132=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_02','Aluminium bronze slot ties',#6131,$,$); +#6133=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_04','Aluminium bronze wall head restraint slip ties',#6131,$,$); +#6134=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_11','Carbon steel cast-in channels',#6131,$,$); +#6135=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_12','Carbon steel movement joint lateral restraint slip ties',#6131,$,$); +#6136=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_13','Carbon steel lateral restraint straps',#6131,$,$); +#6137=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_14','Carbon steel slot ties',#6131,$,$); +#6138=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_15','Carbon steel threaded studding ties',#6131,$,$); +#6139=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_16','Carbon steel tie bars',#6131,$,$); +#6140=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_17','Carbon steel vertical restraint straps',#6131,$,$); +#6141=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_18','Carbon steel wall head restraint slip ties',#6131,$,$); +#6142=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_19','Cavity wall ties',#6131,$,$); +#6143=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_20','Channel slot ties',#6131,$,$); +#6144=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_21','Copper slot ties',#6131,$,$); +#6145=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_22','Copper wall head restraint slip ties',#6131,$,$); +#6146=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_28','Existing wall tie isolating sleeves',#6131,$,$); +#6147=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_33','General-purpose slip ties',#6131,$,$); +#6148=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_36','Head restraint slip ties',#6131,$,$); +#6149=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_46','Lateral restraint ties',#6131,$,$); +#6150=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_50','Masonry repair ties',#6131,$,$); +#6151=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_57','Non-loadbearing wall head restraints',#6131,$,$); +#6152=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_61','Permanent insulation formwork (PIF) connectors',#6131,$,$); +#6153=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_62','Phosphor bronze slot ties',#6131,$,$); +#6154=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_63','Phosphor bronze wall head restraint slip ties',#6131,$,$); +#6155=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_64','Polyester (PET) straps',#6131,$,$); +#6156=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_68','Retaining wall tie rods',#6131,$,$); +#6157=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_69','Restraint belts',#6131,$,$); +#6158=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_70','Roof gutter straps',#6131,$,$); +#6159=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_73','Shear wall ties',#6131,$,$); +#6160=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_74','Slotted wall channels and brackets',#6131,$,$); +#6161=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_75','Stainless steel lateral restraint straps',#6131,$,$); +#6162=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_76','Stainless steel slot ties',#6131,$,$); +#6163=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_77','Stainless steel threaded studding ties',#6131,$,$); +#6164=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_78','Stainless steel tie bars',#6131,$,$); +#6165=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_79','Stainless steel vertical restraint straps',#6131,$,$); +#6166=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_80','Stainless steel wall head restraint slip ties',#6131,$,$); +#6167=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_81','Stainless steel drive ties',#6131,$,$); +#6168=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_82','Stainless steel resin-bonded ties',#6131,$,$); +#6169=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_83','Stainless steel expansion ties',#6131,$,$); +#6170=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_84','Stainless steel cast-in channels',#6131,$,$); +#6171=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_85','Stainless steel cladding channels',#6131,$,$); +#6172=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_86','Stainless steel cladding ties',#6131,$,$); +#6173=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_87','Surface mounted channels',#6131,$,$); +#6174=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_88','Tension or compression bracing products',#6131,$,$); +#6175=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_89','Tension straps',#6131,$,$); +#6176=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_95','Wall starters and connectors',#6131,$,$); +#6177=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_84_97','Water-resistant concrete formwork ties',#6131,$,$); +#6178=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_85','Structural bearings',#5822,$,$); +#6179=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_85_02','Acoustic and vibration resistant bearings',#6178,$,$); +#6180=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_85_06','Bearing strips and mats',#6178,$,$); +#6181=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_85_11','Carbon steel stools',#6178,$,$); +#6182=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_85_30','Flat jacks',#6178,$,$); +#6183=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_85_36','Hard packing',#6178,$,$); +#6184=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_85_60','Padstones',#6178,$,$); +#6185=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_85_74','Rubber bearings',#6178,$,$); +#6186=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_85_80','Sliding surface bearings',#6178,$,$); +#6187=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_85_84','Stainless steel stools',#6178,$,$); +#6188=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_86','Struts and props',#5822,$,$); +#6189=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_86_11','Carbon steel struts',#6188,$,$); +#6190=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_86_30','Formwork props',#6188,$,$); +#6191=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_86_31','Formwork shores',#6188,$,$); +#6192=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_86_76','Screw jacks',#6188,$,$); +#6193=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_86_84','Stainless steel struts',#6188,$,$); +#6194=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_86_89','Trench boxes or shields',#6188,$,$); +#6195=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_86_90','Trench shores',#6188,$,$); +#6196=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_86_91','Trench struts',#6188,$,$); +#6197=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_88','Track beds',#5822,$,$); +#6198=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_88_06','Ballast mats',#6197,$,$); +#6199=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_88_07','Ballast track beds',#6197,$,$); +#6200=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_88_17','Concrete track beds',#6197,$,$); +#6201=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_89','Train arrestors',#5822,$,$); +#6202=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_89_30','Fixed train arrestors',#6201,$,$); +#6203=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_89_31','Friction train arrestors',#6201,$,$); +#6204=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_89_39','Hydraulic train arrestors',#6201,$,$); +#6205=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_90','Trusses and lattice frames',#5822,$,$); +#6206=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_90_02','Aluminium lattice trusses and frames',#6205,$,$); +#6207=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_90_11','Carbon steel lattice floor joists and purlins',#6205,$,$); +#6208=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_90_12','Carbon steel pitched roof trusses',#6205,$,$); +#6209=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_90_36','Hardwood lattice joists',#6205,$,$); +#6210=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_90_37','Hardwood trussed rafters',#6205,$,$); +#6211=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_90_38','Hardwood trusses',#6205,$,$); +#6212=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_90_81','Softwood trusses',#6205,$,$); +#6213=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_90_82','Softwood trussed rafters',#6205,$,$); +#6214=IFCCLASSIFICATIONREFERENCE($,'Pr_20_85_90_84','Steel lattice frames',#6205,$,$); +#6215=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93','Unit structure and general products',#5028,$,$); +#6216=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_33','Glass blocks and panels',#6215,$,$); +#6217=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_33_12','Cellular glass thermal blocks',#6216,$,$); +#6218=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_33_30','Fire rated glass block wall panels',#6216,$,$); +#6219=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_33_31','Glass block dry joint spacers',#6216,$,$); +#6220=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_33_32','Glass block mortar joint spacers',#6216,$,$); +#6221=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_33_33','Glass block wall panels',#6216,$,$); +#6222=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_33_34','Glass blocks',#6216,$,$); +#6223=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_33_52','Mortar jointed glass block wall panels',#6216,$,$); +#6224=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_33_53','Mortar jointed and sealant pointed glass block wall panels',#6216,$,$); +#6225=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_33_76','Sealant jointed glass block wall panels',#6216,$,$); +#6226=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_37','Headwall and swale inlet products',#6215,$,$); +#6227=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_37_62','Plastics headwall units',#6226,$,$); +#6228=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_37_63','Plastics swale inlets',#6226,$,$); +#6229=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_37_65','Precast concrete headwall units',#6226,$,$); +#6230=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_37_66','Precast concrete swale inlets',#6226,$,$); +#6231=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_51','Masonry flooring units',#6215,$,$); +#6232=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_51_02','Aggregate concrete infill blocks',#6231,$,$); +#6233=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_51_05','Autoclaved aerated concrete (AAC) infill blocks',#6231,$,$); +#6234=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_51_28','Expanded polystyrene (EPS) infill blocks',#6231,$,$); +#6235=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52','Masonry walling units',#6215,$,$); +#6236=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_01','Aggregate concrete blocks',#6235,$,$); +#6237=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_02','Aggregate concrete bricks',#6235,$,$); +#6238=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_05','Autoclaved aerated concrete (AAC) blocks',#6235,$,$); +#6239=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_11','Calcium silicate blocks',#6235,$,$); +#6240=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_12','Calcium silicate bricks',#6235,$,$); +#6241=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_13','Cast stone masonry units',#6235,$,$); +#6242=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_14','Clay blocks',#6235,$,$); +#6243=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_15','Clay bricks',#6235,$,$); +#6244=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_23','Dimensioned stones',#6235,$,$); +#6245=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_27','Engineering bricks',#6235,$,$); +#6246=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_33','Glass-reinforced concrete (GRC) blocks',#6235,$,$); +#6247=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_34','Glazed clay bricks',#6235,$,$); +#6248=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_35','Glazed concrete blocks',#6235,$,$); +#6249=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_36','Gypsum blocks',#6235,$,$); +#6250=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_42','Insulated concrete blocks',#6235,$,$); +#6251=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_50','Manufactured stone blocks',#6235,$,$); +#6252=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_56','Natural dimensioned stones',#6235,$,$); +#6253=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_57','Natural rubble stones',#6235,$,$); +#6254=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_58','Natural stone plugs',#6235,$,$); +#6255=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_71','Reclaimed clay bricks',#6235,$,$); +#6256=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_73','Refractory bricks',#6235,$,$); +#6257=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_74','Replacement natural dimensioned stones',#6235,$,$); +#6258=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_75','Salvaged natural stones',#6235,$,$); +#6259=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_87','Terracotta units',#6235,$,$); +#6260=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_52_89','Thin joint autoclaved aerated concrete (AAC) blocks',#6235,$,$); +#6261=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_71','Retaining wall units',#6215,$,$); +#6262=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_71_11','Carbon steel spreader plates',#6261,$,$); +#6263=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_71_15','Concrete interlocking blocks',#6261,$,$); +#6264=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_71_16','Concrete crib wall units',#6261,$,$); +#6265=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_71_17','Concrete panels',#6261,$,$); +#6266=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_71_18','Concrete diaphragm wall units',#6261,$,$); +#6267=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_71_53','Modular reinforced concrete stem wall units',#6261,$,$); +#6268=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_71_65','Preformed stop ends',#6261,$,$); +#6269=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_71_75','Sawn hardwood crib wall units',#6261,$,$); +#6270=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_76','Shaft-lining products',#6215,$,$); +#6271=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_76_11','Carbon steel shaft-lining segments',#6270,$,$); +#6272=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_76_12','Cast iron shaft-lining segments',#6270,$,$); +#6273=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_76_15','Concrete shaft-lining segments',#6270,$,$); +#6274=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_76_80','Spheroidal graphite iron (SGI) shaft-lining segments',#6270,$,$); +#6275=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_84','Structural roofing units',#6215,$,$); +#6276=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_84_15','Concrete arch units',#6275,$,$); +#6277=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_84_16','Concrete dome units',#6275,$,$); +#6278=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_84_84','Structural insulated roof panels',#6275,$,$); +#6279=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_85','Structural walling units',#6215,$,$); +#6280=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_85_14','Concrete solid wall and composite wall units',#6279,$,$); +#6281=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_85_16','Concrete structural insulated panels (SIPs)',#6279,$,$); +#6282=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_85_84','Structural insulated wall panels',#6279,$,$); +#6283=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_85_88','Timber-framed straw-filled panels',#6279,$,$); +#6284=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_90','Tunnel-lining products',#6215,$,$); +#6285=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_90_11','Carbon steel tunnel-lining segments',#6284,$,$); +#6286=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_90_12','Cast iron tunnel-lining segments',#6284,$,$); +#6287=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_90_15','Concrete tunnel-lining segments',#6284,$,$); +#6288=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_90_80','Spheroidal graphite iron (SGI) tunnel-lining segments',#6284,$,$); +#6289=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_90_90','Tunnel segment connectors',#6284,$,$); +#6290=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_95','Tunnel opening products',#6215,$,$); +#6291=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_95_15','Tunnel frame cills',#6290,$,$); +#6292=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_95_44','Tunnel frame jambs',#6290,$,$); +#6293=IFCCLASSIFICATIONREFERENCE($,'Pr_20_93_95_47','Tunnel frame lintels',#6290,$,$); +#6294=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96','Wire structure and general products',#5028,$,$); +#6295=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71','Reinforcement',#6294,$,$); +#6296=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_10','Carbon steel bed joint reinforcement',#6295,$,$); +#6297=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_11','Carbon steel cage reinforcement',#6295,$,$); +#6298=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_12','Carbon steel fabric reinforcement',#6295,$,$); +#6299=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_13','Carbon steel plain bar reinforcement',#6295,$,$); +#6300=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_14','Carbon steel ribbed bar reinforcement',#6295,$,$); +#6301=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_15','Carbon steel post-installed starter bars',#6295,$,$); +#6302=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_16','Carbon steel tendons',#6295,$,$); +#6303=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_17','Copper rod reinforcement',#6295,$,$); +#6304=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_28','Fibre reinforced plastics bar reinforcement',#6295,$,$); +#6305=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_30','Fibrous reinforcement',#6295,$,$); +#6306=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_33','Glass fibre fleece reinforcement',#6295,$,$); +#6307=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_34','Glass fibre mesh reinforcement',#6295,$,$); +#6308=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_35','Glass fibre reinforcement mats',#6295,$,$); +#6309=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_36','Glass fibre reinforcement tendons',#6295,$,$); +#6310=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_51','Mechanical reinforcement couplers',#6295,$,$); +#6311=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_52','Meshwork joint reinforcement',#6295,$,$); +#6312=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_62','Phosphor bronze rod reinforcement',#6295,$,$); +#6313=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_64','Polyester (PES) fibre fleece reinforcement',#6295,$,$); +#6314=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_66','Prefabricated continuity reinforcement strips',#6295,$,$); +#6315=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_67','Prefabricated reinforcement',#6295,$,$); +#6316=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_83','Stainless steel bed joint reinforcement',#6295,$,$); +#6317=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_84','Stainless steel fabric reinforcement',#6295,$,$); +#6318=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_85','Stainless steel plain bar reinforcement',#6295,$,$); +#6319=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_86','Stainless steel ribbed bar reinforcement',#6295,$,$); +#6320=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_87','Stainless steel post-installed starter bars',#6295,$,$); +#6321=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_71_97','Welded wire mesh reinforcement',#6295,$,$); +#6322=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_96','Wire fencing ancillary products',#6294,$,$); +#6323=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_96_11','Carbon steel fencing cleats',#6322,$,$); +#6324=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_96_12','Carbon steel fencing droppers',#6322,$,$); +#6325=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_96_13','Carbon steel fencing rings',#6322,$,$); +#6326=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_96_14','Carbon steel fencing strainers',#6322,$,$); +#6327=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_96_15','Carbon steel fencing stretcher bars',#6322,$,$); +#6328=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_96_16','Carbon steel fencing wedges',#6322,$,$); +#6329=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_96_17','Carbon steel pre-formed fencing lashing rods',#6322,$,$); +#6330=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_96_72','Rotating vane fence toppings',#6322,$,$); +#6331=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97','Wires, ropes, twines and chains',#6294,$,$); +#6332=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_02','Aluminium wires',#6331,$,$); +#6333=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_11','Carbon steel barbed tapes',#6331,$,$); +#6334=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_12','Carbon steel barbed wires',#6331,$,$); +#6335=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_13','Carbon steel chains',#6331,$,$); +#6336=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_14','Carbon steel high tensile barbed wires',#6331,$,$); +#6337=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_15','Carbon steel high tensile line wires',#6331,$,$); +#6338=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_16','Carbon steel razor wires',#6331,$,$); +#6339=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_17','Carbon steel spring wires',#6331,$,$); +#6340=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_18','Carbon steel wire ropes',#6331,$,$); +#6341=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_19','Carbon steel wires',#6331,$,$); +#6342=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_21','Copper alloy wires',#6331,$,$); +#6343=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_27','Electric fence ropes',#6331,$,$); +#6344=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_51','Mixed fibre ropes',#6331,$,$); +#6345=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_56','Natural ropes',#6331,$,$); +#6346=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_57','Natural threads',#6331,$,$); +#6347=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_58','Natural twines',#6331,$,$); +#6348=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_60','Phosphor bronze wires',#6331,$,$); +#6349=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_62','Plastics chains',#6331,$,$); +#6350=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_63','Plastics wires or lines',#6331,$,$); +#6351=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_73','Shock-absorbing lanyards',#6331,$,$); +#6352=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_74','Stainless steel barbed tapes',#6331,$,$); +#6353=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_75','Stainless steel barbed wires',#6331,$,$); +#6354=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_76','Stainless steel chains',#6331,$,$); +#6355=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_77','Stainless steel high tensile barbed wires',#6331,$,$); +#6356=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_78','Stainless steel high tensile line wires',#6331,$,$); +#6357=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_79','Stainless steel razor wires',#6331,$,$); +#6358=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_80','Stainless steel spring wires',#6331,$,$); +#6359=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_81','Stainless steel wire ropes',#6331,$,$); +#6360=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_82','Stainless steel wires',#6331,$,$); +#6361=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_83','Swimming pool flagged ropes',#6331,$,$); +#6362=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_84','Swimming pool false start ropes',#6331,$,$); +#6363=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_85','Swimming pool lane ropes',#6331,$,$); +#6364=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_86','Synthetic chains',#6331,$,$); +#6365=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_87','Synthetic ropes',#6331,$,$); +#6366=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_88','Synthetic threads',#6331,$,$); +#6367=IFCCLASSIFICATIONREFERENCE($,'Pr_20_96_97_89','Synthetic twines',#6331,$,$); +#6368=IFCCLASSIFICATIONREFERENCE($,'Pr_25','Skin products',#4923,$,$); +#6369=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30','Fixed access products',#6368,$,$); +#6370=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30','Floor plates, gratings and edgings',#6369,$,$); +#6371=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_01','Aluminium cold formed planks',#6370,$,$); +#6372=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_02','Aluminium duckboards',#6370,$,$); +#6373=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_03','Aluminium edging sections',#6370,$,$); +#6374=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_04','Aluminium expanded gratings',#6370,$,$); +#6375=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_05','Aluminium open bar metal gratings',#6370,$,$); +#6376=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_06','Aluminium solid metal plates',#6370,$,$); +#6377=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_12','Carbon steel cold formed planks',#6370,$,$); +#6378=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_14','Carbon steel edging sections',#6370,$,$); +#6379=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_16','Carbon steel expanded gratings',#6370,$,$); +#6380=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_18','Carbon steel open bar metal gratings',#6370,$,$); +#6381=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_20','Carbon steel solid metal plates',#6370,$,$); +#6382=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_22','Concrete planks',#6370,$,$); +#6383=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_34','Glass-reinforced plastics (GRP) moulded open mesh gratings',#6370,$,$); +#6384=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_36','Hardwood duckboards',#6370,$,$); +#6385=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_58','Open bar glass-reinforced plastics (GRP) gratings',#6370,$,$); +#6386=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_63','Plastics perforated gratings',#6370,$,$); +#6387=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_80','Softwood duckboards',#6370,$,$); +#6388=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_81','Solid glass-reinforced plastics (GRP) plates',#6370,$,$); +#6389=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_82','Stainless steel cold formed planks',#6370,$,$); +#6390=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_83','Stainless steel edging sections',#6370,$,$); +#6391=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_84','Stainless steel expanded gratings',#6370,$,$); +#6392=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_85','Stainless steel open bar metal gratings',#6370,$,$); +#6393=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_30_86','Stainless steel solid metal plates',#6370,$,$); +#6394=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_36','Handrails',#6369,$,$); +#6395=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_36_03','Aluminium handrails',#6394,$,$); +#6396=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_36_11','Carbon steel handrails',#6394,$,$); +#6397=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_36_30','Fibre-reinforced polymer handrails',#6394,$,$); +#6398=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_36_34','Grab rails',#6394,$,$); +#6399=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_36_50','Manufactured stone handrails',#6394,$,$); +#6400=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_36_63','Plastics handrails',#6394,$,$); +#6401=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_36_84','Stainless steel handrails',#6394,$,$); +#6402=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_36_96','Wood handrails',#6394,$,$); +#6403=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_75','Safety cages',#6369,$,$); +#6404=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_75_02','Aluminium ladder safety cages',#6403,$,$); +#6405=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_75_15','Carbon steel ladder safety cages',#6403,$,$); +#6406=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_75_80','Stainless steel ladder safety cages',#6403,$,$); +#6407=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85','Stair and ladder units',#6369,$,$); +#6408=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_02','Access ladders',#6407,$,$); +#6409=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_03','Aluminium loft ladders',#6407,$,$); +#6410=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_11','Cat ladders',#6407,$,$); +#6411=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_16','Curved internal staircases',#6407,$,$); +#6412=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_22','Drainage access chamber ladders',#6407,$,$); +#6413=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_23','Drainage access chamber steps',#6407,$,$); +#6414=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_36','Hardwood loft ladders',#6407,$,$); +#6415=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_48','Lift pit ladders',#6407,$,$); +#6416=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_64','Pool ladders',#6407,$,$); +#6417=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_65','Pool stepladders',#6407,$,$); +#6418=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_73','Roll-up ladders',#6407,$,$); +#6419=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_79','Sliding ladders',#6407,$,$); +#6420=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_83','Steel loft ladders',#6407,$,$); +#6421=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_84','Spiral internal staircases',#6407,$,$); +#6422=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_85','Step-over ladders',#6407,$,$); +#6423=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_86','Straight internal staircases',#6407,$,$); +#6424=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_85_90','Travelling ladders',#6407,$,$); +#6425=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86','Surface level traffic control products',#6369,$,$); +#6426=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_03','Aluminium alloy vehicle flow plates',#6425,$,$); +#6427=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_04','Aluminium alloy vehicle stops',#6425,$,$); +#6428=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_11','Carbon steel vehicle flow plates',#6425,$,$); +#6429=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_12','Carbon steel vehicle stops',#6425,$,$); +#6430=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_15','Concrete demarcation units',#6425,$,$); +#6431=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_60','Pavement extenders',#6425,$,$); +#6432=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_72','Rising kerbs',#6425,$,$); +#6433=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_73','Rising ramp vehicle barriers',#6425,$,$); +#6434=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_74','Rising spike vehicle stops',#6425,$,$); +#6435=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_75','Rubber vehicle stops',#6425,$,$); +#6436=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_83','Speed restriction ramps',#6425,$,$); +#6437=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_88','Timber vehicle stops',#6425,$,$); +#6438=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_90','Traffic calming speed cushions',#6425,$,$); +#6439=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_86_91','Traffic islands',#6425,$,$); +#6440=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90','Treads and landing units',#6369,$,$); +#6441=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_10','Carbon steel stair treads',#6440,$,$); +#6442=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_11','Concrete glazed stair treads',#6440,$,$); +#6443=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_12','Concrete glazed stair landing panels',#6440,$,$); +#6444=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_13','Concrete helical stair flight units',#6440,$,$); +#6445=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_14','Concrete spiral stair flight units',#6440,$,$); +#6446=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_15','Concrete stair flight and landing units',#6440,$,$); +#6447=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_16','Concrete stair flight units',#6440,$,$); +#6448=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_17','Concrete stair landing units',#6440,$,$); +#6449=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_18','Concrete step units',#6440,$,$); +#6450=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_33','Glass stair treads',#6440,$,$); +#6451=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_36','Hardwood stair treads',#6440,$,$); +#6452=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_63','Plastics stair treads',#6440,$,$); +#6453=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_81','Softwood stair treads',#6440,$,$); +#6454=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_83','Stainless steel stair treads',#6440,$,$); +#6455=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_84','Stone stair treads',#6440,$,$); +#6456=IFCCLASSIFICATIONREFERENCE($,'Pr_25_30_90_85','Stone step units',#6440,$,$); +#6457=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31','Formless skin products',#6368,$,$); +#6458=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_28','Expanding foams',#6457,$,$); +#6459=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_28_65','Polyisocyanurate (PIR) foam insulation',#6458,$,$); +#6460=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_28_66','Polyurethane (PUR) injected foam insulation',#6458,$,$); +#6461=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_28_67','Polyurethane (PUR) foam insulation',#6458,$,$); +#6462=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_28_93','Urea-formaldehyde foam (UFF) insulation',#6458,$,$); +#6463=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_28_94','Vermin and insect-proof expanding foams',#6458,$,$); +#6464=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_48','Loose insulation',#6457,$,$); +#6465=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_48_12','Cellulose fibre loose insulation',#6464,$,$); +#6466=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_48_27','Expanded cork loose insulation',#6464,$,$); +#6467=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_48_28','Expanded polystyrene (EPS) bead insulation',#6464,$,$); +#6468=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_48_34','Granular mineral wool insulation',#6464,$,$); +#6469=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_48_48','Loose-fill mineral wool fibre insulation',#6464,$,$); +#6470=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_48_61','Perlite loose insulation',#6464,$,$); +#6471=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_48_66','Polyurethane (PUR) foam chip insulation',#6464,$,$); +#6472=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_48_71','Recycled paper loose insulation',#6464,$,$); +#6473=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_48_76','Sea grass loose insulation',#6464,$,$); +#6474=IFCCLASSIFICATIONREFERENCE($,'Pr_25_31_48_94','Vermiculite loose insulation',#6464,$,$); +#6475=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57','Non-rigid sheet, mat and strip skin products',#6368,$,$); +#6476=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06','Batt and quilt products',#6475,$,$); +#6477=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_02','Aerogel blanket insulation',#6476,$,$); +#6478=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_15','Cotton fibre batt insulation',#6476,$,$); +#6479=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_28','Felt backing insulation',#6476,$,$); +#6480=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_30','Flexible glass wool mat insulation',#6476,$,$); +#6481=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_31','Flexible rock wool mat insulation',#6476,$,$); +#6482=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_32','Formed recycled paper insulation',#6476,$,$); +#6483=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_34','Glass fibre insulation',#6476,$,$); +#6484=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_37','Hemp fibre insulation',#6476,$,$); +#6485=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_47','Lift car protective quilts',#6476,$,$); +#6486=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_50','Mineral fibre slab insulation',#6476,$,$); +#6487=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_52','Mineral wool flexible insulation',#6476,$,$); +#6488=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_53','Mineral wool insulation',#6476,$,$); +#6489=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_54','Mineral wool resilient layer sound insulation',#6476,$,$); +#6490=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_55','Mineral wool resilient strip sound insulation',#6476,$,$); +#6491=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_56','Mineral wool slab insulation',#6476,$,$); +#6492=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_57','Multifoil blanket insulation',#6476,$,$); +#6493=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_70','Reflective foil insulation',#6476,$,$); +#6494=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_71','Resilient layer insulation',#6476,$,$); +#6495=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_76','Sheep wool insulation',#6476,$,$); +#6496=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_94','Vacuum insulated panels',#6476,$,$); +#6497=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_06_97','Wood fibre batt insulation',#6476,$,$); +#6498=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_08','Bitumen-based membranes, sheets and fabrics',#6475,$,$); +#6499=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_08_08','Bitumen sheets',#6498,$,$); +#6500=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_08_58','Pitch polymer membranes',#6498,$,$); +#6501=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_08_71','Reinforced bitumen membrane perforated underlays',#6498,$,$); +#6502=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_08_75','Reinforced bitumen roofing sheets',#6498,$,$); +#6503=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_10','Building papers and vapour permeable sheets',#6475,$,$); +#6504=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_10_04','Aluminium foil/ kraft paper laminates',#6503,$,$); +#6505=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_10_08','Bitumen bonded kraft papers',#6503,$,$); +#6506=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_10_09','Building papers',#6503,$,$); +#6507=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_10_12','Cellulose based building papers',#6503,$,$); +#6508=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_10_37','High density polyethylene (PE-HD) vapour permeable sheets',#6503,$,$); +#6509=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_10_45','Kraft papers',#6503,$,$); +#6510=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_10_47','Low density polyethylene (PE-LD) vapour permeable sheets',#6503,$,$); +#6511=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_10_62','Polyethylene coated kraft papers',#6503,$,$); +#6512=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_10_64','Polyolefin vapour permeable sheets',#6503,$,$); +#6513=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_10_66','Polypropylene vapour permeable sheets',#6503,$,$); +#6514=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_10_68','Polypropylene and polyethylene laminate vapour permeable sheets',#6503,$,$); +#6515=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_10_94','Vapour permeable sheets',#6503,$,$); +#6516=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21','Damp proof courses and cavity trays',#6475,$,$); +#6517=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_02','Aluminium damp proof courses and cavity trays',#6516,$,$); +#6518=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_06','Bitumen-based damp proof courses and cavity trays',#6516,$,$); +#6519=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_08','Bitumen polymer damp proof courses and cavity trays',#6516,$,$); +#6520=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_11','Carbon steel damp proof courses and cavity trays',#6516,$,$); +#6521=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_12','Cavity closer and damp proof course supports',#6516,$,$); +#6522=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_13','Clay brick damp proof courses',#6516,$,$); +#6523=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_14','Cold-applied roofing membrane adhesive damp proof course joint sealers',#6516,$,$); +#6524=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_16','Coping or capping damp proof courses',#6516,$,$); +#6525=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_18','Copper damp proof courses and cavity trays',#6516,$,$); +#6526=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_27','Ethylene propylene (EP) damp proof courses and cavity trays',#6516,$,$); +#6527=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_33','Gas resistant preformed cavity trays',#6516,$,$); +#6528=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_34','Gas resistant preformed cavity trays and cloaks',#6516,$,$); +#6529=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_35','Gas-resistant damp proof courses',#6516,$,$); +#6530=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_36','Granite damp proof courses',#6516,$,$); +#6531=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_42','Insertion cavity trays',#6516,$,$); +#6532=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_43','Insulated damp proof courses',#6516,$,$); +#6533=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_44','Joist seals',#6516,$,$); +#6534=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_48','Lead damp proof courses and cavity trays',#6516,$,$); +#6535=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_50','Mastic asphalt (MA) damp proof courses',#6516,$,$); +#6536=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_61','Pitch polymer damp proof courses and cavity trays',#6516,$,$); +#6537=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_63','Polyethylene (PE) damp proof courses and cavity trays',#6516,$,$); +#6538=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_64','Polypropylene (PP) damp proof courses and cavity trays',#6516,$,$); +#6539=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_65','Polymeric damp proof courses',#6516,$,$); +#6540=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_66','Preformed cavity trays',#6516,$,$); +#6541=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_67','Preformed cavity trays and cloaks',#6516,$,$); +#6542=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_68','Preformed damp proof courses',#6516,$,$); +#6543=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_72','Rising damp remedial units',#6516,$,$); +#6544=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_80','Slate damp proof courses',#6516,$,$); +#6545=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_21_99','Zinc damp proof courses',#6516,$,$); +#6546=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51','Membranes, liners, flexible sheets and fabrics',#6475,$,$); +#6547=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_02','Acrylonitrile butadiene styrene (ABS) studded membranes',#6546,$,$); +#6548=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_10','Butyl rubber (polyisobutylene isoprene (IIR)) geomembranes',#6546,$,$); +#6549=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_11','Carborundum slip-resistant paper',#6546,$,$); +#6550=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_13','Chlorinated polyethylene (PE-C) geomembranes',#6546,$,$); +#6551=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_14','Chlorosulfonated polyethylene (PE-CS) geomembranes',#6546,$,$); +#6552=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_16','Coated polyester fabrics',#6546,$,$); +#6553=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_27','Ethylene propylene diene monomer (EPDM) geomembranes',#6546,$,$); +#6554=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_30','Flexible pond liners',#6546,$,$); +#6555=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_31','Flexible polyolefin (FPO) polymeric membranes',#6546,$,$); +#6556=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_33','Glass fibre fleeces',#6546,$,$); +#6557=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_35','Glass-reinforced plastics (GRP) sheet liners',#6546,$,$); +#6558=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_36','High-density polyethylene (PE-HD) studded sheets',#6546,$,$); +#6559=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_38','High impact polystyrene (HIPS) studded sheets',#6546,$,$); +#6560=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_42','Integrated flexible photovoltaic (PV) module membranes',#6546,$,$); +#6561=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_51','Membrane walkways',#6546,$,$); +#6562=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_52','Metallized plastics window films',#6546,$,$); +#6563=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_54','Modified acrylic fabric',#6546,$,$); +#6564=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_60','Plastics window films',#6546,$,$); +#6565=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_61','Plastics preformed liners',#6546,$,$); +#6566=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_66','Polymeric membranes',#6546,$,$); +#6567=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_67','Polymeric membrane collars',#6546,$,$); +#6568=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_68','Polypropylene (PP) studded sheets',#6546,$,$); +#6569=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_70','Polyvinyl chloride geomembranes',#6546,$,$); +#6570=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_74','Rubber studded sheets',#6546,$,$); +#6571=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_79','Slip-resistant sheets and strips',#6546,$,$); +#6572=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_88','Thermoplastic polyolefin elastomer (TPE) polymeric membranes',#6546,$,$); +#6573=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_51_95','Vinyl ethylene terpolymer (VET) polymeric membranes',#6546,$,$); +#6574=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_53','Moisture retention sheets',#6475,$,$); +#6575=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_53_30','Foamed aminoplastic resin moisture retention mats',#6574,$,$); +#6576=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_53_50','Mineral wool water retention geotextiles',#6574,$,$); +#6577=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_53_62','Polyacrylonitrile (PAN) water retention geotextiles',#6574,$,$); +#6578=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_53_63','Polyamide water retention geotextiles',#6574,$,$); +#6579=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_53_65','Polypropylene water retention geotextiles',#6574,$,$); +#6580=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56','Netting and non-reinforcement mesh',#6475,$,$); +#6581=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_07','Bird deterrent nets',#6580,$,$); +#6582=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_14','Cleft chestnut palisade rolls',#6580,$,$); +#6583=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_15','Continuous chain link metal mesh',#6580,$,$); +#6584=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_16','Coarse woven plastics mesh',#6580,$,$); +#6585=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_27','Expanded metal mesh',#6580,$,$); +#6586=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_28','Extruded plastics mesh',#6580,$,$); +#6587=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_29','Fine woven plastics mesh',#6580,$,$); +#6588=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_34','Glass fibre mesh',#6580,$,$); +#6589=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_52','Metallic nets',#6580,$,$); +#6590=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_56','Natural nets',#6580,$,$); +#6591=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_61','Perforated metal mesh',#6580,$,$); +#6592=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_64','Plastics nets',#6580,$,$); +#6593=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_85','Spun-bonded plastics mesh',#6580,$,$); +#6594=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_95','Welded metal mesh',#6580,$,$); +#6595=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_96','Wire netting',#6580,$,$); +#6596=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_56_97','Woven metal mesh',#6580,$,$); +#6597=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_61','Plant-fibre based membranes, liners, flexible sheet and fabrics',#6475,$,$); +#6598=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_61_15','Coir geotextiles',#6597,$,$); +#6599=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_61_29','Flax geotextiles',#6597,$,$); +#6600=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_61_37','Hemp geotextiles',#6597,$,$); +#6601=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_61_44','Jute geotextiles',#6597,$,$); +#6602=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_61_59','Plant and natural fibre linings',#6597,$,$); +#6603=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_61_60','Paper pulp linings',#6597,$,$); +#6604=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_61_79','Sisal membranes',#6597,$,$); +#6605=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_61_80','Sisal jute mix membranes',#6597,$,$); +#6606=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_61_95','Wood fibre membranes',#6597,$,$); +#6607=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_61_97','Wool membranes',#6597,$,$); +#6608=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_61_98','Wool felt membranes',#6597,$,$); +#6609=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_65','Plastics membranes',#6475,$,$); +#6610=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_65_37','High density polyethylene (PE-HD) sheets',#6609,$,$); +#6611=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_65_47','Low density polyethylene (PE-LD) sheets',#6609,$,$); +#6612=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_65_60','Plastics sheets',#6609,$,$); +#6613=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_65_62','Polyester sheets',#6609,$,$); +#6614=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_65_63','Polyethylene sheets',#6609,$,$); +#6615=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_65_65','Polypropylene sheets',#6609,$,$); +#6616=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_65_66','Polypropylene and polyethylene laminate sheets',#6609,$,$); +#6617=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_65_67','Polytetrafluorethylene (PTFE) sheets',#6609,$,$); +#6618=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_65_70','Polyvinylidene fluoride (PVDF) sheets',#6609,$,$); +#6619=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_65_92','Unplasticized polyvinyl chloride (PVC-U) sheets',#6609,$,$); +#6620=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_85','Synthetic filter fabrics',#6475,$,$); +#6621=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_85_10','Capillary fleece',#6620,$,$); +#6622=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_85_62','Polyester fibre fleece',#6620,$,$); +#6623=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_85_64','Polyester filter geotextiles',#6620,$,$); +#6624=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_85_66','Polyethylene filter geotextiles',#6620,$,$); +#6625=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_85_68','Polypropylene filter geotextiles',#6620,$,$); +#6626=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_85_70','Polyvinylidene fluoride (PVDF) hydrophobic geotextiles',#6620,$,$); +#6627=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_90','Tensile, stretch and suspended fabrics',#6475,$,$); +#6628=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_90_03','Aramid tensile fabrics',#6627,$,$); +#6629=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_90_15','Cotton canvas tensile fabrics',#6627,$,$); +#6630=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_90_29','Fabrics for tensile applications',#6627,$,$); +#6631=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_90_34','Glass fibre tensile fabrics',#6627,$,$); +#6632=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_90_63','Polyester tensile fabrics',#6627,$,$); +#6633=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_90_67','Polytetrafluoroethylene (PTFE) tensile fabrics',#6627,$,$); +#6634=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_90_69','Polyurethane coated polyester stretch fabric membranes',#6627,$,$); +#6635=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_90_71','Polyvinyl chloride (PVC) stretch fabric membranes',#6627,$,$); +#6636=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_90_75','Sailcloth',#6627,$,$); +#6637=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_90_81','Solar glass weave tensile fabrics',#6627,$,$); +#6638=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_90_84','Stretch fabric membranes',#6627,$,$); +#6639=IFCCLASSIFICATIONREFERENCE($,'Pr_25_57_90_85','Suspended fabric panels',#6627,$,$); +#6640=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71','Rigid board, panel and sheet products',#6368,$,$); +#6641=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14','Cladding and lining panels (lightweight cladding and roofing panels)',#6640,$,$); +#6642=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_01','Aggregate-faced glass reinforced plastics (GRP) panels',#6641,$,$); +#6643=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_02','Aluminium cassette panels',#6641,$,$); +#6644=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_03','Applied facing precast concrete panels',#6641,$,$); +#6645=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_04','Aluminium insulating sandwich panels',#6641,$,$); +#6646=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_05','Aluminium composite material (ACM) panels',#6641,$,$); +#6647=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_06','Aluminium composite panels',#6641,$,$); +#6648=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_07','Aluminium external panels',#6641,$,$); +#6649=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_08','Aluminium infill panels',#6641,$,$); +#6650=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_09','Aluminium internal panels',#6641,$,$); +#6651=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_10','Aluminium-faced aluminium core panels',#6641,$,$); +#6652=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_11','Carbon steel composite panels',#6641,$,$); +#6653=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_12','Carbon steel external panels',#6641,$,$); +#6654=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_13','Carbon steel infill panels',#6641,$,$); +#6655=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_14','Carbon steel internal panels',#6641,$,$); +#6656=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_15','Ceramic panels',#6641,$,$); +#6657=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_16','Column casings',#6641,$,$); +#6658=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_17','Ceramic-faced aluminium core panels',#6641,$,$); +#6659=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_18','Composite and recycled plastics sheets',#6641,$,$); +#6660=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_19','Composite stone panels',#6641,$,$); +#6661=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_20','Compressed rock fibre panels',#6641,$,$); +#6662=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_21','Copper alloy-faced aluminium core panels',#6641,$,$); +#6663=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_22','Carbon steel insulating sandwich panels',#6641,$,$); +#6664=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_30','Fibre cement panels',#6641,$,$); +#6665=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_31','Fireproof casings',#6641,$,$); +#6666=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_33','Glass-faced aluminium core panels',#6641,$,$); +#6667=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_34','Glass reinforced plastics (GRP) panels',#6641,$,$); +#6668=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_52','Monolithic precast concrete cladding panels',#6641,$,$); +#6669=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_56','Natural stone panels',#6641,$,$); +#6670=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_57','Natural stone-faced aluminium core panels',#6641,$,$); +#6671=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_62','Plastics sheet wall claddings',#6641,$,$); +#6672=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_63','Platinum-faced aluminium core panels',#6641,$,$); +#6673=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_65','Pre-weathered zinc cassette panels',#6641,$,$); +#6674=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_71','Reconstituted stone panels',#6641,$,$); +#6675=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_75','Sandwich precast concrete cladding panels',#6641,$,$); +#6676=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_77','Self-finished precast concrete cladding panels',#6641,$,$); +#6677=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_81','Stainless steel-faced aluminium core panels',#6641,$,$); +#6678=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_82','Stainless steel cassette panels',#6641,$,$); +#6679=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_83','Stainless steel composite panels',#6641,$,$); +#6680=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_84','Stainless steel external panels',#6641,$,$); +#6681=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_85','Stainless steel infill panels',#6641,$,$); +#6682=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_86','Stainless steel internal panels',#6641,$,$); +#6683=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_87','Stainless steel insulating sandwich panels',#6641,$,$); +#6684=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_88','Terracotta panels',#6641,$,$); +#6685=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_90','Titanium-faced aluminium core panels',#6641,$,$); +#6686=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_98','Wood fibre-reinforced thermosetting resin external panels',#6641,$,$); +#6687=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_14_99','Zinc-faced aluminium core panels',#6641,$,$); +#6688=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29','Falsework and formwork',#6640,$,$); +#6689=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_04','Architectural finish permanent formwork linings',#6688,$,$); +#6690=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_11','Carbon steel permanent joint formers',#6688,$,$); +#6691=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_14','Collapsible (wet) board substructure formwork',#6688,$,$); +#6692=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_15','Collapsible board substructure formwork',#6688,$,$); +#6693=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_16','Compressible board substructure formwork',#6688,$,$); +#6694=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_17','Concrete permanent side forms',#6688,$,$); +#6695=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_19','Controlled permeability formwork',#6688,$,$); +#6696=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_24','Duct formers',#6688,$,$); +#6697=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_28','Expanded carbon steel mesh formwork',#6688,$,$); +#6698=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_37','High density expanded polystyrene (HDPS) ventilated substructure formwork',#6688,$,$); +#6699=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_56','Non-critical permanent formwork',#6688,$,$); +#6700=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_60','Permanent concrete composite wall panels',#6688,$,$); +#6701=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_62','Permanent insulation formwork (PIF)',#6688,$,$); +#6702=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_64','Permanent timber formwork',#6688,$,$); +#6703=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_72','Ribbed carbon steel mesh formwork',#6688,$,$); +#6704=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_76','Scaffolding and accessories',#6688,$,$); +#6705=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_86','Suspended in situ concrete construction permanent insulation formwork (PIF)',#6688,$,$); +#6706=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_29_88','Timber scaffold boards',#6688,$,$); +#6707=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33','Glass and glazing sheets and profiles',#6640,$,$); +#6708=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_02','Annealed glass sheets',#6707,$,$); +#6709=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_03','Antique glass',#6707,$,$); +#6710=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_14','Composite glass sheets',#6707,$,$); +#6711=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_16','Corrugated wired glass sheets',#6707,$,$); +#6712=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_20','Cylinder blown glass sheets',#6707,$,$); +#6713=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_33','Glass beams',#6707,$,$); +#6714=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_34','Glass fins',#6707,$,$); +#6715=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_35','Glass panels',#6707,$,$); +#6716=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_36','Hand blown crown glass',#6707,$,$); +#6717=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_37','Heat strengthened glass sheets',#6707,$,$); +#6718=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_42','Insulated glass units (IGUs)',#6707,$,$); +#6719=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_46','Laminated glass sheets',#6707,$,$); +#6720=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_47','Lead and X-ray glass sheets',#6707,$,$); +#6721=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_65','Plastics glazing sheets',#6707,$,$); +#6722=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_67','Plastics laminated glazing sheets',#6707,$,$); +#6723=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_77','Sealed insulated glass units',#6707,$,$); +#6724=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_84','Stained glass sheets',#6707,$,$); +#6725=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_88','Thermally toughened glass sheets',#6707,$,$); +#6726=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_92','U-profiled glass channels',#6707,$,$); +#6727=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_33_97','Wired glass sheets',#6707,$,$); +#6728=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_42','Infill panels',#6640,$,$); +#6729=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_42_12','Cement-bonded wood-wool infill panels',#6728,$,$); +#6730=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_42_52','Metal tray infill panels',#6728,$,$); +#6731=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_42_54','Mineral fibre infill panels',#6728,$,$); +#6732=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_42_59','Open-cell infill panels',#6728,$,$); +#6733=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_42_60','Panel diffuser infill panels',#6728,$,$); +#6734=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_42_63','Plastics-faced gypsum plasterboard infill panels',#6728,$,$); +#6735=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_42_70','Raised access floor panels',#6728,$,$); +#6736=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_42_71','Raised access floor panels with finish',#6728,$,$); +#6737=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_42_72','Resin-bonded mineral wool infill panels',#6728,$,$); +#6738=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_42_73','Rigid urethane foam infill panels',#6728,$,$); +#6739=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_42_94','Veneered wood-composite infill panels',#6728,$,$); +#6740=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_43','Interior linings',#6640,$,$); +#6741=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_43_33','Glass-reinforced plastics (GRP) ceilings',#6740,$,$); +#6742=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_43_34','Glass-reinforced plastics (GRP) linings',#6740,$,$); +#6743=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_43_62','Plastics linings',#6740,$,$); +#6744=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_44','Joint fillers',#6640,$,$); +#6745=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_44_06','Bitumen-impregnated softboard joint fillers',#6744,$,$); +#6746=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_44_08','Bitumen rubber expansion joint fillers',#6744,$,$); +#6747=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_44_15','Cork board joint fillers',#6744,$,$); +#6748=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_44_28','Extruded polyethylene (PE) foam joint fillers',#6744,$,$); +#6749=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_44_77','Sealant backer rods',#6744,$,$); +#6750=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50','Metal panels',#6640,$,$); +#6751=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_02','Aluminium expanded mesh panels',#6750,$,$); +#6752=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_03','Aluminium vertical bar panels',#6750,$,$); +#6753=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_04','Aluminium sheet panels',#6750,$,$); +#6754=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_06','Base boards',#6750,$,$); +#6755=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_12','Carbon steel expanded mesh panels',#6750,$,$); +#6756=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_13','Carbon steel framed vertical bar and rail panels',#6750,$,$); +#6757=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_14','Carbon steel framed vertical bar panels',#6750,$,$); +#6758=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_15','Carbon steel framed vertical section panels',#6750,$,$); +#6759=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_16','Carbon steel palisade fence panels',#6750,$,$); +#6760=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_17','Carbon steel panels',#6750,$,$); +#6761=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_18','Carbon steel vertical section and rail panels',#6750,$,$); +#6762=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_19','Carbon steel welded mesh panels',#6750,$,$); +#6763=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_20','Cast iron vertical bar and rail panels',#6750,$,$); +#6764=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_21','Composite fence panels',#6750,$,$); +#6765=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_22','Composite panels',#6750,$,$); +#6766=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_23','Composite wildlife panels',#6750,$,$); +#6767=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_24','Decorative metal panels',#6750,$,$); +#6768=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_39','Hurdles',#6750,$,$); +#6769=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_51','Mesh panels',#6750,$,$); +#6770=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_60','Palisade panels',#6750,$,$); +#6771=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_61','Panels with vertical infill',#6750,$,$); +#6772=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_79','Sheet panels',#6750,$,$); +#6773=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_80','Stainless steel expanded mesh panels',#6750,$,$); +#6774=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_81','Stainless steel vertical bar panels',#6750,$,$); +#6775=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_82','Stainless steel vertical bar and rail panels',#6750,$,$); +#6776=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_83','Stainless steel sheet panels',#6750,$,$); +#6777=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_84','Stainless steel welded mesh panels',#6750,$,$); +#6778=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_85','Stainless steel woven mesh panels',#6750,$,$); +#6779=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_87','Steel noise barrier panels',#6750,$,$); +#6780=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_93','Vitreous enamel steel composite panels',#6750,$,$); +#6781=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_94','Vitreous enamel steel panels',#6750,$,$); +#6782=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_95','Welded steel hurdles',#6750,$,$); +#6783=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_96','Wrought iron decorative panels',#6750,$,$); +#6784=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_97','Wrought iron vertical bar panels',#6750,$,$); +#6785=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_50_98','Wrought iron vertical bar and rail panels',#6750,$,$); +#6786=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51','Metal sheets and strips',#6640,$,$); +#6787=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_01','Aluminium sheets, strips and plates',#6786,$,$); +#6788=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_02','Aluminium long strips',#6786,$,$); +#6789=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_03','Aluminium profiled sheets',#6786,$,$); +#6790=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_04','Aluminium profiled sheet decking',#6786,$,$); +#6791=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_05','Aluminium sheets',#6786,$,$); +#6792=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_06','Aluminium traditional sheets',#6786,$,$); +#6793=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_10','Carbon steel long strips',#6786,$,$); +#6794=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_11','Carbon steel linings',#6786,$,$); +#6795=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_12','Carbon steel pressed panels',#6786,$,$); +#6796=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_14','Carbon steel sheet walkway reinforcement',#6786,$,$); +#6797=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_15','Carbon steel sheets',#6786,$,$); +#6798=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_16','Copper long strips',#6786,$,$); +#6799=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_17','Copper traditional sheets',#6786,$,$); +#6800=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_33','Galvanized carbon steel profiled sheets',#6786,$,$); +#6801=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_38','Hollow-core metal sheets',#6786,$,$); +#6802=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_46','Lead machine cast sheets',#6786,$,$); +#6803=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_47','Lead rolled sheets',#6786,$,$); +#6804=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_52','Metal profiled sheets',#6786,$,$); +#6805=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_84','Stainless steel long strips and sheets',#6786,$,$); +#6806=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_85','Stainless steel profiled sheets',#6786,$,$); +#6807=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_86','Stainless steel sheets',#6786,$,$); +#6808=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_87','Stainless steel traditional sheets',#6786,$,$); +#6809=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_88','Steel plate, sheet and strip',#6786,$,$); +#6810=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_89','Steel profiled sheet',#6786,$,$); +#6811=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_97','Zinc traditional sheets',#6786,$,$); +#6812=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_98','Zinc soft temper alloy strips',#6786,$,$); +#6813=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_51_99','Zinc standard temper alloy strips',#6786,$,$); +#6814=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52','Mineral-based boards and sheets',#6640,$,$); +#6815=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_11','Carbon-neutral gypsum plasterboards',#6814,$,$); +#6816=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_12','Carbon steel-faced plasterboard panels',#6814,$,$); +#6817=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_13','Cellular glass insulation boards',#6814,$,$); +#6818=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_15','Compressed mineral wool fire protection boards',#6814,$,$); +#6819=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_17','Compressed vermiculite fire protection boards',#6814,$,$); +#6820=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_21','Enhanced-strength gypsum plasterboards',#6814,$,$); +#6821=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_22','Expanded perlite boards',#6814,$,$); +#6822=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_23','Fibre-reinforced calcium silicate boards',#6814,$,$); +#6823=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_24','Fibre-reinforced calcium silicate fire protection boards',#6814,$,$); +#6824=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_25','Fibre-reinforced cement boards',#6814,$,$); +#6825=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_26','Fibre-reinforced cement profiled sheets',#6814,$,$); +#6826=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_27','Fibre-reinforced cement sheets',#6814,$,$); +#6827=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_28','Fibre-reinforced cement weatherboards',#6814,$,$); +#6828=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_29','Fibre-reinforced gypsum boards',#6814,$,$); +#6829=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_30','Fibre-reinforced gypsum floor boards',#6814,$,$); +#6830=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_31','Fibre-reinforced magnesium silicate boards',#6814,$,$); +#6831=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_32','Flexible plasterboards',#6814,$,$); +#6832=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_33','Fire-resistant gypsum plasterboards',#6814,$,$); +#6833=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_34','Gypsum baseboards',#6814,$,$); +#6834=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_35','Gypsum core boards',#6814,$,$); +#6835=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_36','Gypsum planks',#6814,$,$); +#6836=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_38','Gypsum plasterboards',#6814,$,$); +#6837=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_39','Gypsum plasterboard with combined properties',#6814,$,$); +#6838=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_40','Gypsum sheathing plasterboards',#6814,$,$); +#6839=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_41','Impact-resistant gypsum plasterboards',#6814,$,$); +#6840=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_42','High-density gypsum plasterboards',#6814,$,$); +#6841=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_47','Linoleum composite laminate strips and boards',#6814,$,$); +#6842=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_50','Magnesium oxide boards',#6814,$,$); +#6843=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_52','Moisture-resistant gypsum plasterboards',#6814,$,$); +#6844=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_63','Plasterboard panels',#6814,$,$); +#6845=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_80','Sound insulation gypsum plasterboards',#6814,$,$); +#6846=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_84','Standard gypsum plasterboards',#6814,$,$); +#6847=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_88','Thermal laminate gypsum plasterboards',#6814,$,$); +#6848=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_94','Vapour check gypsum plasterboards',#6814,$,$); +#6849=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_95','Vermiculite-silicate fire protection boards',#6814,$,$); +#6850=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_52_99','X-ray resistant gypsum plasterboards',#6814,$,$); +#6851=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_53','Mirrors',#6640,$,$); +#6852=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_53_06','Bathroom mirrors',#6851,$,$); +#6853=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_53_30','Framed glass mirrors',#6851,$,$); +#6854=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_53_31','Framed metal mirrors',#6851,$,$); +#6855=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_53_32','Framed plastics mirrors',#6851,$,$); +#6856=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_53_46','Large mirrors',#6851,$,$); +#6857=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_53_65','Platform mirrors',#6851,$,$); +#6858=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_53_70','Rail mirrors',#6851,$,$); +#6859=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_53_73','Road mirrors',#6851,$,$); +#6860=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_53_82','Small mirrors',#6851,$,$); +#6861=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_53_91','Unframed glass mirrors',#6851,$,$); +#6862=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_53_92','Unframed metal mirrors',#6851,$,$); +#6863=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_53_93','Unframed plastics mirrors',#6851,$,$); +#6864=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57','Non-metal barrier panels',#6640,$,$); +#6865=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_11','Cement-bonded particleboard framed panels',#6864,$,$); +#6866=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_12','Concrete base boards',#6864,$,$); +#6867=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_13','Concrete parapet base panels',#6864,$,$); +#6868=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_14','Concrete base panels',#6864,$,$); +#6869=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_15','Concrete fence panel tops',#6864,$,$); +#6870=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_16','Concrete fence panels',#6864,$,$); +#6871=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_17','Concrete containment parapet units',#6864,$,$); +#6872=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_18','Concrete safety barrier panels',#6864,$,$); +#6873=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_19','Concrete noise barrier panels',#6864,$,$); +#6874=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_22','Decorative concrete fence panels',#6864,$,$); +#6875=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_24','Decorative timber panels',#6864,$,$); +#6876=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_34','Glass barrier panels',#6864,$,$); +#6877=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_35','Glazing plastics framed panels',#6864,$,$); +#6878=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_37','Hardwood base boards',#6864,$,$); +#6879=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_38','Hardwood framed panels',#6864,$,$); +#6880=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_39','Hardwood palisade panels',#6864,$,$); +#6881=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_40','Hazel wattle hurdles',#6864,$,$); +#6882=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_44','Jet blast deflectors',#6864,$,$); +#6883=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_60','Partition panels',#6864,$,$); +#6884=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_61','Partition screens',#6864,$,$); +#6885=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_62','Plastics framed panels',#6864,$,$); +#6886=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_63','Plastics panels',#6864,$,$); +#6887=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_64','Plastics panel fence tops',#6864,$,$); +#6888=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_65','Plywood framed panels',#6864,$,$); +#6889=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_66','Polymer based boards',#6864,$,$); +#6890=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_67','Polymer based panels',#6864,$,$); +#6891=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_73','Room divider panels',#6864,$,$); +#6892=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_80','Sliding stacking panel partitions',#6864,$,$); +#6893=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_81','Softwood base boards',#6864,$,$); +#6894=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_82','Softwood framed panels',#6864,$,$); +#6895=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_83','Softwood palisade fence panels',#6864,$,$); +#6896=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_87','Timber base boards',#6864,$,$); +#6897=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_88','Timber board panels',#6864,$,$); +#6898=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_90','Timber sheet panels',#6864,$,$); +#6899=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_97','Wattle hurdles',#6864,$,$); +#6900=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_57_98','Willow wattle hurdles',#6864,$,$); +#6901=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63','Plastics-based boards and sheets',#6640,$,$); +#6902=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_15','Compact or solid grade high-pressure laminate (HPL) boards',#6901,$,$); +#6903=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_24','Drainage layer corrugated boards',#6901,$,$); +#6904=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_26','Expanded polystyrene (EPS) boards',#6901,$,$); +#6905=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_27','Extruded polyethylene (PE) foam boards',#6901,$,$); +#6906=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_29','Extruded polystyrene (XPS) boards',#6901,$,$); +#6907=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_33','Glass-reinforced plastics (GRP) profiled panels',#6901,$,$); +#6908=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_34','Glass-reinforced plastics (GRP) profiled sheets',#6901,$,$); +#6909=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_38','Hollow-core plastics sheets',#6901,$,$); +#6910=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_59','Phenolic foam boards',#6901,$,$); +#6911=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_60','Plastics and composite material boards',#6901,$,$); +#6912=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_61','Plastics base boards',#6901,$,$); +#6913=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_62','Plastics composite and recycled sheets',#6901,$,$); +#6914=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_63','Plastics composite laminate strips and boards',#6901,$,$); +#6915=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_64','Plastics weatherboards',#6901,$,$); +#6916=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_65','Polycarbonate profiled sheets',#6901,$,$); +#6917=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_66','Polyisocyanurate (PIR) foam boards',#6901,$,$); +#6918=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_67','Polyurethane (PUR) foam boards',#6901,$,$); +#6919=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_72','Recycled plastics deck boards',#6901,$,$); +#6920=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_81','Solid surface resin-based sheets',#6901,$,$); +#6921=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_92','Unplasticized polyvinyl chloride (PVC-U) deck boards',#6901,$,$); +#6922=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_63_93','Unplasticized polyvinyl chloride (PVC-U) profiled sheets',#6901,$,$); +#6923=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_94','Veneers and facings',#6640,$,$); +#6924=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_94_06','Balancing veneers',#6923,$,$); +#6925=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_94_22','Decorative continuous laminates (DCL or CPL)',#6923,$,$); +#6926=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_94_29','Fabric facings',#6923,$,$); +#6927=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_94_37','High-pressure decorative laminates (HPL or HPDL)',#6923,$,$); +#6928=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_94_46','Leather facings',#6923,$,$); +#6929=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_94_51','Melamine veneer facings',#6923,$,$); +#6930=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_94_52','Metal sheet facings',#6923,$,$); +#6931=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_94_94','Veneer edgings and lippings',#6923,$,$); +#6932=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_94_95','Vinyl sheet facings',#6923,$,$); +#6933=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_94_98','Wood veneers',#6923,$,$); +#6934=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97','Wood-based boards',#6640,$,$); +#6935=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_05','Bitumen-impregnated fibreboards',#6934,$,$); +#6936=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_07','Bitumen-impregnated softboards',#6934,$,$); +#6937=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_08','Blockboard core plywoods',#6934,$,$); +#6938=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_12','Cement-bonded particleboards',#6934,$,$); +#6939=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_16','Corkboards',#6934,$,$); +#6940=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_17','Cork composite laminate strips and boards',#6934,$,$); +#6941=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_21','Decorative laminated papers',#6934,$,$); +#6942=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_22','Decorative laminated plastics sheet veneered panels',#6934,$,$); +#6943=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_30','Fire-retardant plywoods',#6934,$,$); +#6944=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_33','General and utility veneer plywoods',#6934,$,$); +#6945=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_34','Gypsum-bonded fire protection boards',#6934,$,$); +#6946=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_35','Gypsum-bonded wood particle boards',#6934,$,$); +#6947=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_36','Hardboards',#6934,$,$); +#6948=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_37','Hardwood deck boards',#6934,$,$); +#6949=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_38','Hardwood fence boards',#6934,$,$); +#6950=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_42','Hardwood strips',#6934,$,$); +#6951=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_43','Hardwood weatherboards',#6934,$,$); +#6952=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_44','Hollow-core particleboards',#6934,$,$); +#6953=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_46','Laminboard core plywoods',#6934,$,$); +#6954=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_50','Marine plywoods',#6934,$,$); +#6955=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_52','Medium boards',#6934,$,$); +#6956=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_53','Medium density fibreboards',#6934,$,$); +#6957=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_54','Modified wood boards',#6934,$,$); +#6958=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_55','Modified wood weather boards',#6934,$,$); +#6959=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_58','Oriented strand boards',#6934,$,$); +#6960=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_60','Particleboards',#6934,$,$); +#6961=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_65','Polymer-coated plywoods',#6934,$,$); +#6962=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_77','Softboards',#6934,$,$); +#6963=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_78','Softwood deck boards',#6934,$,$); +#6964=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_79','Softwood fence boards',#6934,$,$); +#6965=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_83','Softwood strips',#6934,$,$); +#6966=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_84','Softwood weatherboards',#6934,$,$); +#6967=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_85','Specialist veneer plywoods',#6934,$,$); +#6968=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_86','Structural veneer plywoods',#6934,$,$); +#6969=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_87','Timber floor boards',#6934,$,$); +#6970=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_88','Timber lining boards',#6934,$,$); +#6971=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_89','Timber sarking boards',#6934,$,$); +#6972=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_91','Visual grade general veneer plywoods',#6934,$,$); +#6973=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_92','Wood fibre boards',#6934,$,$); +#6974=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_93','Wood laminate strips and boards',#6934,$,$); +#6975=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_94','Wood-plastics composite deck boards',#6934,$,$); +#6976=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_95','Wood-plastics composite weatherboards',#6934,$,$); +#6977=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_97','Wood-wool boards',#6934,$,$); +#6978=IFCCLASSIFICATIONREFERENCE($,'Pr_25_71_97_98','Wood-resin composite weatherboards',#6934,$,$); +#6979=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80','Smoke and fire control products',#6368,$,$); +#6980=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_79','Smoke and fire barriers',#6979,$,$); +#6981=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_79_01','Active smoke barriers',#6980,$,$); +#6982=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_79_03','Angled active fire curtain barriers',#6980,$,$); +#6983=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_79_14','Concertina fire curtains',#6980,$,$); +#6984=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_79_15','Concertina smoke curtains',#6980,$,$); +#6985=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_79_37','High temperature active smoke barriers',#6980,$,$); +#6986=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_79_38','Horizontal active fire curtain barriers',#6980,$,$); +#6987=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_79_39','Horizontal smoke curtains',#6980,$,$); +#6988=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_79_86','Static smoke barriers',#6980,$,$); +#6989=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_79_94','Vertical active fire curtain barriers',#6980,$,$); +#6990=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_79_95','Vertical smoke curtains',#6980,$,$); +#6991=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_79_96','Vertical smoke strip curtains',#6980,$,$); +#6992=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_80','Smoke and fire cavity barriers',#6979,$,$); +#6993=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_80_14','Coated woven glass fibre cloth flexible cavity barriers',#6992,$,$); +#6994=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_80_30','Fire insulating caps',#6992,$,$); +#6995=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_80_42','Intumescent coated foil mesh flexible cavity barriers',#6992,$,$); +#6996=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_80_43','Intumescent sheet cavity barriers',#6992,$,$); +#6997=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_80_44','Intumescent sleeved mineral wool cavity fire barriers',#6992,$,$); +#6998=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_80_51','Mineral wool wire reinforced mattress cavity barriers',#6992,$,$); +#6999=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_80_79','Sleeved mineral wool cavity barriers',#6992,$,$); +#7000=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_80_82','Sprayed mineral coated wire mesh flexible cavity barriers',#6992,$,$); +#7001=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_80_96','Wired mineral wool batt flexible cavity barriers',#6992,$,$); +#7002=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_81','Smoke and fire stopping',#6979,$,$); +#7003=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_81_12','Ceramic fibre fire stopping',#7002,$,$); +#7004=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_81_29','Flexible intumescent gap seals',#7002,$,$); +#7005=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_81_34','Glass oxide fire stopping',#7002,$,$); +#7006=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_81_42','Intumescent linear gap seals',#7002,$,$); +#7007=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_81_43','Intumescent pillows',#7002,$,$); +#7008=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_81_44','Intumescent trunking pillows',#7002,$,$); +#7009=IFCCLASSIFICATIONREFERENCE($,'Pr_25_80_81_51','Mineral wool fire stopping',#7002,$,$); +#7010=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93','Unit skin products',#6368,$,$); +#7011=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_45','Kerb units',#7010,$,$); +#7012=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_45_05','Asphalt kerbs',#7011,$,$); +#7013=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_45_18','Concrete kerbs',#7011,$,$); +#7014=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_45_21','Concrete safety kerbs',#7011,$,$); +#7015=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_45_24','Concrete transition and dropper kerbs',#7011,$,$); +#7016=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_45_26','Conservation kerbs',#7011,$,$); +#7017=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_45_56','Natural stone kerbs',#7011,$,$); +#7018=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_45_60','Pin kerbs',#7011,$,$); +#7019=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_45_62','Plastics kerbs',#7011,$,$); +#7020=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_45_70','Road kerbs',#7011,$,$); +#7021=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_45_90','Transition kerbs',#7011,$,$); +#7022=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_47','Level crossing surfacing products',#7010,$,$); +#7023=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_47_27','Embedded rail modular concrete level crossing units',#7022,$,$); +#7024=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_47_52','Modular panel level crossings',#7022,$,$); +#7025=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50','Masonry capping and coping units',#7010,$,$); +#7026=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_10','Calcium silicate capping units',#7025,$,$); +#7027=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_11','Calcium silicate coping units',#7025,$,$); +#7028=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_13','Cast stone capping units',#7025,$,$); +#7029=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_14','Cast stone coping units',#7025,$,$); +#7030=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_16','Clay brick capping units',#7025,$,$); +#7031=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_17','Clay brick coping units',#7025,$,$); +#7032=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_19','Clayware capping units',#7025,$,$); +#7033=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_20','Clayware coping units',#7025,$,$); +#7034=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_22','Concrete capping units',#7025,$,$); +#7035=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_23','Concrete coping units',#7025,$,$); +#7036=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_34','Glass-reinforced concrete (GRC) coping units',#7025,$,$); +#7037=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_55','Natural stone capping units',#7025,$,$); +#7038=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_56','Natural stone coping units',#7025,$,$); +#7039=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_76','Slate capping units',#7025,$,$); +#7040=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_50_77','Slate coping units',#7025,$,$); +#7041=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_51','Masonry dressing units',#7010,$,$); +#7042=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_51_35','Glass-reinforced concrete (GRC) built-in gable vents',#7041,$,$); +#7043=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_51_36','Glass-reinforced concrete (GRC) built-in keystones',#7041,$,$); +#7044=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_51_37','Glass-reinforced concrete (GRC) built-in plinths and string courses',#7041,$,$); +#7045=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_51_38','Glass-reinforced concrete (GRC) built-in quoins',#7041,$,$); +#7046=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_51_39','Glass-reinforced concrete (GRC) dressing gable vents',#7041,$,$); +#7047=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_51_40','Glass-reinforced concrete (GRC) dressing keystones',#7041,$,$); +#7048=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_51_41','Glass-reinforced concrete (GRC) dressing plinths and string courses',#7041,$,$); +#7049=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_51_42','Glass-reinforced concrete (GRC) dressing quoins',#7041,$,$); +#7050=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_51_56','Natural stone cornices',#7041,$,$); +#7051=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_51_57','Natural stone dentils',#7041,$,$); +#7052=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_51_58','Natural stone quoins',#7041,$,$); +#7053=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52','Masonry openings units',#7010,$,$); +#7054=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52_11','Calcium silicate sills',#7053,$,$); +#7055=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52_12','Cast stone sills',#7053,$,$); +#7056=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52_13','Clay brick sills',#7053,$,$); +#7057=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52_14','Clayware sills',#7053,$,$); +#7058=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52_15','Concrete sills',#7053,$,$); +#7059=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52_28','External extension sills',#7053,$,$); +#7060=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52_33','Glass-reinforced concrete (GRC) bay window sills',#7053,$,$); +#7061=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52_34','Glass-reinforced concrete (GRC) door canopies',#7053,$,$); +#7062=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52_35','Glass-reinforced concrete (GRC) door surrounds',#7053,$,$); +#7063=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52_36','Glass-reinforced concrete (GRC) sills',#7053,$,$); +#7064=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52_37','Glass-reinforced concrete (GRC) fireplace and hearth surrounds',#7053,$,$); +#7065=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52_56','Natural stone sills',#7053,$,$); +#7066=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_52_76','Slate sills',#7053,$,$); +#7067=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_54','Metal capping and coping units',#7010,$,$); +#7068=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_54_02','Aluminium capping units',#7067,$,$); +#7069=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_54_03','Aluminium coping units',#7067,$,$); +#7070=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_54_11','Carbon steel capping units',#7067,$,$); +#7071=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_54_12','Carbon steel coping units',#7067,$,$); +#7072=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_54_15','Copper capping units',#7067,$,$); +#7073=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_54_16','Copper coping units',#7067,$,$); +#7074=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_54_46','Lead capping units',#7067,$,$); +#7075=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_54_47','Lead coping units',#7067,$,$); +#7076=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_54_98','Zinc capping units',#7067,$,$); +#7077=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_54_99','Zinc coping units',#7067,$,$); +#7078=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_55','Metal sills',#7010,$,$); +#7079=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_55_84','Steel sills',#7078,$,$); +#7080=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60','Paving units',#7010,$,$); +#7081=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_02','Aluminium edges',#7080,$,$); +#7082=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_08','Blister tactile pavers',#7080,$,$); +#7083=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_09','Clay pavers',#7080,$,$); +#7084=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_10','Clay paving tiles',#7080,$,$); +#7085=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_11','Clay surface channels',#7080,$,$); +#7086=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_12','Combined drainage and kerb units',#7080,$,$); +#7087=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_13','Concrete cellular pavers',#7080,$,$); +#7088=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_14','Concrete surface channels',#7080,$,$); +#7089=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_15','Concrete edging units',#7080,$,$); +#7090=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_16','Concrete flags',#7080,$,$); +#7091=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_17','Concrete paving blocks',#7080,$,$); +#7092=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_19','Concrete pavers',#7080,$,$); +#7093=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_20','Concrete quadrant and angle kerbs',#7080,$,$); +#7094=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_22','Concrete setts',#7080,$,$); +#7095=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_23','Concrete tactile flags',#7080,$,$); +#7096=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_26','Corduroy tactile pavers',#7080,$,$); +#7097=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_33','Glass-reinforced concrete (GRC) paving tiles',#7080,$,$); +#7098=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_52','Natural stone blocks',#7080,$,$); +#7099=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_53','Natural stone flags',#7080,$,$); +#7100=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_54','Natural stone cobbles',#7080,$,$); +#7101=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_55','Natural stone surface channels',#7080,$,$); +#7102=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_57','Natural stone setts',#7080,$,$); +#7103=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_58','Natural stone paving slabs',#7080,$,$); +#7104=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_59','Natural stone tactile pavers',#7080,$,$); +#7105=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_61','Plastics cellular pavers',#7080,$,$); +#7106=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_63','Plastics pavers',#7080,$,$); +#7107=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_65','Plastics surface channels',#7080,$,$); +#7108=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_78','Special composite paving units',#7080,$,$); +#7109=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_60_80','Stainless steel edges',#7080,$,$); +#7110=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_70','Rail track paving',#7010,$,$); +#7111=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_70_11','Cattle-cum-trespass guards',#7110,$,$); +#7112=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_70_70','Rail infill panels',#7110,$,$); +#7113=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72','Roofing and cladding units',#7010,$,$); +#7114=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_08','Bitumen membrane shingles',#7113,$,$); +#7115=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_11','Ceramic slates',#7113,$,$); +#7116=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_12','Clay interlocking tiles',#7113,$,$); +#7117=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_13','Clay plain tiles',#7113,$,$); +#7118=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_14','Clay tile coursing fittings',#7113,$,$); +#7119=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_15','Clay tile ornamental fittings',#7113,$,$); +#7120=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_16','Clay tile vertical tiling angle fittings',#7113,$,$); +#7121=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_17','Concrete interlocking tiles',#7113,$,$); +#7122=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_18','Concrete plain tiles',#7113,$,$); +#7123=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_19','Concrete tile coursing fittings',#7113,$,$); +#7124=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_20','Concrete tile ornamental fittings',#7113,$,$); +#7125=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_21','Concrete tile vertical tiling angle fittings',#7113,$,$); +#7126=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_30','Fibre cement slates',#7113,$,$); +#7127=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_31','Fibre-cement slate coursing fittings',#7113,$,$); +#7128=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_36','Hardwood shakes',#7113,$,$); +#7129=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_37','Hardwood shingles',#7113,$,$); +#7130=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_52','Metal tiles',#7113,$,$); +#7131=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_56','Natural slates',#7113,$,$); +#7132=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_57','Natural stone slates',#7113,$,$); +#7133=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_72','Reconstituted interlocking slates',#7113,$,$); +#7134=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_73','Reconstituted slate coursing fittings',#7113,$,$); +#7135=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_79','Slate coursing fittings',#7113,$,$); +#7136=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_96','Wood shakes',#7113,$,$); +#7137=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_97','Wood shingles',#7113,$,$); +#7138=IFCCLASSIFICATIONREFERENCE($,'Pr_25_93_72_98','Wood shingle pattern fittings',#7113,$,$); +#7139=IFCCLASSIFICATIONREFERENCE($,'Pr_25_96','Grid and grating skin products',#6368,$,$); +#7140=IFCCLASSIFICATIONREFERENCE($,'Pr_25_96_35','Grids and grilles',#7139,$,$); +#7141=IFCCLASSIFICATIONREFERENCE($,'Pr_25_96_35_03','Aluminium cattle grids',#7140,$,$); +#7142=IFCCLASSIFICATIONREFERENCE($,'Pr_25_96_35_11','Carbon steel cattle grids',#7140,$,$); +#7143=IFCCLASSIFICATIONREFERENCE($,'Pr_25_96_35_31','Footway gratings',#7140,$,$); +#7144=IFCCLASSIFICATIONREFERENCE($,'Pr_25_96_35_37','Headwall and outfall grilles',#7140,$,$); +#7145=IFCCLASSIFICATIONREFERENCE($,'Pr_25_96_35_53','Metal armouring grilles',#7140,$,$); +#7146=IFCCLASSIFICATIONREFERENCE($,'Pr_25_96_35_71','Recycled plastics cattle grids',#7140,$,$); +#7147=IFCCLASSIFICATIONREFERENCE($,'Pr_25_96_35_76','Sewage screens',#7140,$,$); +#7148=IFCCLASSIFICATIONREFERENCE($,'Pr_25_96_35_96','Water grilles',#7140,$,$); +#7149=IFCCLASSIFICATIONREFERENCE($,'Pr_30','Opening products',#4923,$,$); +#7150=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31','Formless openings products',#7149,$,$); +#7151=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_68','Putties and glazing compounds',#7150,$,$); +#7152=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_68_42','Intumescent putties',#7151,$,$); +#7153=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_68_47','Linseed oil putties',#7151,$,$); +#7154=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_68_51','Metal casement putties',#7151,$,$); +#7155=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_68_56','Non-setting glazing compounds',#7151,$,$); +#7156=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_68_74','Rubberizing glazing compounds',#7151,$,$); +#7157=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76','Sealants',#7150,$,$); +#7158=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_02','Acrylic construction joint sealants',#7157,$,$); +#7159=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_09','Butyl rubber construction joint sealants',#7157,$,$); +#7160=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_14','Cold-applied bituminous joint sealants',#7157,$,$); +#7161=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_15','Cold-applied concrete pavement bituminous joint sealants',#7157,$,$); +#7162=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_16','Construction joint sealants',#7157,$,$); +#7163=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_26','Edge sealants',#7157,$,$); +#7164=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_27','Electrical insulating compounds',#7157,$,$); +#7165=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_33','Glazing compounds and sealants',#7157,$,$); +#7166=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_34','Glazing joint sealants',#7157,$,$); +#7167=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_38','Hot-applied bituminous joint sealants',#7157,$,$); +#7168=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_39','Hydrophilic sealants',#7157,$,$); +#7169=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_40','Intumescent firestop sealants',#7157,$,$); +#7170=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_41','Intumescent foam fillers',#7157,$,$); +#7171=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_58','Oil-based mastic joint sealants',#7157,$,$); +#7172=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_62','Polysulfide construction joint sealants',#7157,$,$); +#7173=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_63','Polysulfide glazing compounds and sealants',#7157,$,$); +#7174=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_65','Polyurethane (PUR) construction joint sealants',#7157,$,$); +#7175=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_66','Polyurethane (PUR) expanding foam fillers',#7157,$,$); +#7176=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_77','Silicone construction joint sealants',#7157,$,$); +#7177=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_78','Silicone glazing compounds and sealants',#7157,$,$); +#7178=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_84','Structural sealant glazing bonding sealants',#7157,$,$); +#7179=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_85','Structural sealant glazing weather sealants',#7157,$,$); +#7180=IFCCLASSIFICATIONREFERENCE($,'Pr_30_31_76_96','Waterproof gap filling sealants',#7157,$,$); +#7181=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36','Hardware products',#7149,$,$); +#7182=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08','Bolting, latching and locking hardware',#7181,$,$); +#7183=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_06','Barrel bolts',#7182,$,$); +#7184=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_11','Cabinet locks',#7182,$,$); +#7185=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_12','Cam locks',#7182,$,$); +#7186=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_13','Cavity sliding door locks',#7182,$,$); +#7187=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_15','Coin-operated locks',#7182,$,$); +#7188=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_16','Combination padlocks',#7182,$,$); +#7189=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_18','Cremorne bolts',#7182,$,$); +#7190=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_19','Cylinder locks',#7182,$,$); +#7191=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_20','Deadbolts',#7182,$,$); +#7192=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_21','Digital door locks',#7182,$,$); +#7193=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_22','Door bolts',#7182,$,$); +#7194=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_23','Door catches',#7182,$,$); +#7195=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_24','Door latches',#7182,$,$); +#7196=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_25','Door chains and locks',#7182,$,$); +#7197=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_26','Door privacy indicator bolts',#7182,$,$); +#7198=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_27','Electric locks',#7182,$,$); +#7199=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_28','Emergency exit devices',#7182,$,$); +#7200=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_29','Espagnolette bolts',#7182,$,$); +#7201=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_30','Fanlight catches',#7182,$,$); +#7202=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_31','Field gate spring catch sets',#7182,$,$); +#7203=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_32','Flush bolts',#7182,$,$); +#7204=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_33','Furniture locks',#7182,$,$); +#7205=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_34','Gate latches and catches',#7182,$,$); +#7206=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_35','Gate throw over loops',#7182,$,$); +#7207=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_42','Indicator locks',#7182,$,$); +#7208=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_43','Key card locks',#7182,$,$); +#7209=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_44','Key deposit locks',#7182,$,$); +#7210=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_45','Knob locks',#7182,$,$); +#7211=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_46','Lever handle locks',#7182,$,$); +#7212=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_48','Locker hasps',#7182,$,$); +#7213=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_51','Microswitch locks',#7182,$,$); +#7214=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_52','Mortice bolts',#7182,$,$); +#7215=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_53','Mortice locks',#7182,$,$); +#7216=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_54','Multipoint door locks',#7182,$,$); +#7217=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_56','Night latches',#7182,$,$); +#7218=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_60','Pad bolts',#7182,$,$); +#7219=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_61','Padlock hasps and staples',#7182,$,$); +#7220=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_62','Padlocks and keys',#7182,$,$); +#7221=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_63','Panic exit devices',#7182,$,$); +#7222=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_68','Push-button locks',#7182,$,$); +#7223=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_71','Rim locks',#7182,$,$); +#7224=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_73','Roller catches',#7182,$,$); +#7225=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_75','Safety deposit locks',#7182,$,$); +#7226=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_76','Sash locks',#7182,$,$); +#7227=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_77','Single point bolts',#7182,$,$); +#7228=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_80','Sliding security screen door locks',#7182,$,$); +#7229=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_84','Special function door locks',#7182,$,$); +#7230=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_87','Thief resistant door locks',#7182,$,$); +#7231=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_88','Time delay locks',#7182,$,$); +#7232=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_91','Tubular mortice latches',#7182,$,$); +#7233=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_94','Vending machine locks',#7182,$,$); +#7234=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_95','Window casement fasteners',#7182,$,$); +#7235=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_96','Window latches',#7182,$,$); +#7236=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_97','Window locks',#7182,$,$); +#7237=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_08_98','Window sash fasteners',#7182,$,$); +#7238=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_33','General hardware',#7181,$,$); +#7239=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_33_20','Door edge protectors',#7238,$,$); +#7240=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_33_22','Door knockers',#7238,$,$); +#7241=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_33_24','Door stops',#7238,$,$); +#7242=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_33_27','Escutcheons',#7238,$,$); +#7243=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_33_29','Finger plates',#7238,$,$); +#7244=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_33_31','Fixed boot scrapers',#7238,$,$); +#7245=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_33_45','Kick plates',#7238,$,$); +#7246=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_33_68','Push plates',#7238,$,$); +#7247=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_33_72','Roses',#7238,$,$); +#7248=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_33_76','Security viewers',#7238,$,$); +#7249=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36','Hinges and hanging hardware',#7181,$,$); +#7250=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_04','Anti finger-trap stiles',#7249,$,$); +#7251=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_06','Ball-bearing hinges',#7249,$,$); +#7252=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_07','Barrel hinges',#7249,$,$); +#7253=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_08','Boxed sash window hanging fittings',#7249,$,$); +#7254=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_09','Butt door hinges',#7249,$,$); +#7255=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_10','Butt window hinges',#7249,$,$); +#7256=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_11','Cabinet and counter top hinges',#7249,$,$); +#7257=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_15','Concealed hinges',#7249,$,$); +#7258=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_16','Continuous hinges',#7249,$,$); +#7259=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_17','Cranked hinges',#7249,$,$); +#7260=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_22','Door pivots',#7249,$,$); +#7261=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_23','Door track and running gear',#7249,$,$); +#7262=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_24','Drawer runners',#7249,$,$); +#7263=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_28','Field gate hinges',#7249,$,$); +#7264=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_29','Floor springs',#7249,$,$); +#7265=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_30','Flush hinges',#7249,$,$); +#7266=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_31','Friction hinges',#7249,$,$); +#7267=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_32','Friction pivot hinges',#7249,$,$); +#7268=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_34','Gate hinges',#7249,$,$); +#7269=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_46','Lift-off hinges',#7249,$,$); +#7270=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_66','Projection door hinges',#7249,$,$); +#7271=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_67','Projection window hinges',#7249,$,$); +#7272=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_71','Rising butt door hinges',#7249,$,$); +#7273=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_75','Sash window spiral balances',#7249,$,$); +#7274=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_79','Single axis door hinges',#7249,$,$); +#7275=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_80','Single axis window hinges',#7249,$,$); +#7276=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_84','Spring hinges',#7249,$,$); +#7277=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_88','Tee hinges',#7249,$,$); +#7278=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_36_96','Window hinges',#7249,$,$); +#7279=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59','Opening hardware',#7181,$,$); +#7280=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_15','Controlled door closers',#7279,$,$); +#7281=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_22','Door coordinators',#7279,$,$); +#7282=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_24','Door limiting stays',#7279,$,$); +#7283=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_25','Door lever handle sets',#7279,$,$); +#7284=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_29','Flush pull handles',#7279,$,$); +#7285=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_31','Furniture stays',#7279,$,$); +#7286=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_32','Garage door holders',#7279,$,$); +#7287=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_33','Gate closers',#7279,$,$); +#7288=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_34','Gate handles',#7279,$,$); +#7289=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_35','Gate springs',#7279,$,$); +#7290=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_36','Gate wheels',#7279,$,$); +#7291=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_38','Holders and hooks',#7279,$,$); +#7292=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_45','Knobs',#7279,$,$); +#7293=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_50','Magnetic hold',#7279,$,$); +#7294=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_52','Midrail push plates',#7279,$,$); +#7295=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_64','Pull handles',#7279,$,$); +#7296=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_76','Sash window pulls',#7279,$,$); +#7297=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_78','Screen door closers',#7279,$,$); +#7298=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_92','Uncontrolled door closers',#7279,$,$); +#7299=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_94','Window casement stays',#7279,$,$); +#7300=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_95','Window latch and lock operating handles',#7279,$,$); +#7301=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_96','Window over centre casement stays',#7279,$,$); +#7302=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_97','Window remote manual openers',#7279,$,$); +#7303=IFCCLASSIFICATIONREFERENCE($,'Pr_30_36_59_98','Window restrictor stays',#7279,$,$); +#7304=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59','Openings and opening component products',#7149,$,$); +#7305=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_01','Access ramps',#7304,$,$); +#7306=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_01_11','Vehicle ramps',#7305,$,$); +#7307=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_01_23','Dog ramps',#7305,$,$); +#7308=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_01_27','Equipment loading ramps',#7305,$,$); +#7309=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_01_90','Train boarding ramps',#7305,$,$); +#7310=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_01_96','Wheelchair ramps',#7305,$,$); +#7311=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07','Blinds and shading devices',#7304,$,$); +#7312=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_02','Aluminium shutters',#7311,$,$); +#7313=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_03','Anti-glare screens',#7311,$,$); +#7314=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_05','Awnings',#7311,$,$); +#7315=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_07','Blackout blinds',#7311,$,$); +#7316=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_26','External roller blinds',#7311,$,$); +#7317=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_27','External venetian blinds',#7311,$,$); +#7318=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_60','Panel blinds',#7311,$,$); +#7319=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_64','Pinoleum blinds',#7311,$,$); +#7320=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_66','Pleated blinds',#7311,$,$); +#7321=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_68','Polyvinyl chloride (PVC) shutters',#7311,$,$); +#7322=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_72','Roller blinds',#7311,$,$); +#7323=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_73','Roman blinds',#7311,$,$); +#7324=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_86','Sunscreens',#7311,$,$); +#7325=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_94','Venetian blinds',#7311,$,$); +#7326=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_95','Vertical blinds',#7311,$,$); +#7327=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_07_96','Wood shutters',#7311,$,$); +#7328=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09','Brise-soleils and components',#7304,$,$); +#7329=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_01','Aluminium brise-soleil brace arms/struts',#7328,$,$); +#7330=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_02','Aluminium brise-soleil carrier members',#7328,$,$); +#7331=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_03','Aluminium brise-soleil louvre blades',#7328,$,$); +#7332=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_04','Aluminium brise-soleil support arms',#7328,$,$); +#7333=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_05','Aluminium brise-soleil units',#7328,$,$); +#7334=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_11','Carbon steel brise-soleil brace arms/struts',#7328,$,$); +#7335=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_12','Carbon steel brise-soleil carrier members',#7328,$,$); +#7336=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_13','Carbon steel brise-soleil louvre blades',#7328,$,$); +#7337=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_14','Carbon steel brise-soleil support arms',#7328,$,$); +#7338=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_15','Carbon steel brise-soleil units',#7328,$,$); +#7339=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_33','Glass brise-soleil louvre blades',#7328,$,$); +#7340=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_62','Plastics brise-soleil louvre blades',#7328,$,$); +#7341=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_63','Plastics brise-soleil units',#7328,$,$); +#7342=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_82','Stainless steel brise-soleil brace arms/struts',#7328,$,$); +#7343=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_83','Stainless steel brise-soleil carrier members',#7328,$,$); +#7344=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_84','Stainless steel brise-soleil louvre blades',#7328,$,$); +#7345=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_85','Stainless steel brise-soleil support arms',#7328,$,$); +#7346=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_86','Stainless steel brise-soleil units',#7328,$,$); +#7347=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_90','Wood brise-soleil carrier members',#7328,$,$); +#7348=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_91','Wood brise-soleil louvre blades',#7328,$,$); +#7349=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_92','Wood brise-soleil support arms',#7328,$,$); +#7350=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_09_93','Wood brise-soleil units',#7328,$,$); +#7351=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23','Door frames and leaves',#7304,$,$); +#7352=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_02','Aluminium door frames',#7351,$,$); +#7353=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_11','Carbon steel door frames',#7351,$,$); +#7354=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_15','Composite door frames',#7351,$,$); +#7355=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_16','Composite door leaves',#7351,$,$); +#7356=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_32','Frameless glass door leaves',#7351,$,$); +#7357=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_34','Glass reinforced plastics (GRP) door leaves',#7351,$,$); +#7358=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_47','Louvre door leaves',#7351,$,$); +#7359=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_50','Matchboarded door leaves',#7351,$,$); +#7360=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_53','Metal door leaves',#7351,$,$); +#7361=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_84','Stainless steel door frames',#7351,$,$); +#7362=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_91','Unplasticized polyvinyl chloride (PVC-U) door frames',#7351,$,$); +#7363=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_92','Unplasticized polyvinyl chloride (PVC-U) door leaves',#7351,$,$); +#7364=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_96','Wood door frames',#7351,$,$); +#7365=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_97','Wood flush door leaves',#7351,$,$); +#7366=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_23_98','Wood panelled door leaves',#7351,$,$); +#7367=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24','Doorsets',#7304,$,$); +#7368=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_04','Automatic revolving doorsets',#7367,$,$); +#7369=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_14','Collapsible gate and grille sets',#7367,$,$); +#7370=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_15','Combination doorsets',#7367,$,$); +#7371=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_16','Composite doorsets',#7367,$,$); +#7372=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_28','Fire doorsets',#7367,$,$); +#7373=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_30','Flexible doorsets',#7367,$,$); +#7374=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_34','Glass reinforced plastics (GRP) doorsets',#7367,$,$); +#7375=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_37','High security doorsets',#7367,$,$); +#7376=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_38','High speed doorsets',#7367,$,$); +#7377=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_48','Loading bay doorsets',#7367,$,$); +#7378=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_49','Louvre doorsets',#7367,$,$); +#7379=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_50','Manual revolving doorsets',#7367,$,$); +#7380=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_52','Metal doorsets',#7367,$,$); +#7381=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_64','Polyvinyl chloride (PVC) strip curtain sets',#7367,$,$); +#7382=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_75','Sectional overhead doorsets',#7367,$,$); +#7383=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_80','Sliding door and partition sets',#7367,$,$); +#7384=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_81','Sliding folding doorsets',#7367,$,$); +#7385=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_83','Sliding folding shutters',#7367,$,$); +#7386=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_92','Unplasticized polyvinyl chloride (PVC-U) doorsets',#7367,$,$); +#7387=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_93','Up-and-over doorsets',#7367,$,$); +#7388=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_24_97','Wood doorsets',#7367,$,$); +#7389=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_28','Escape products',#7304,$,$); +#7390=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_28_26','Escape chairs',#7389,$,$); +#7391=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_28_27','Escape chutes',#7389,$,$); +#7392=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_28_28','Escape slides',#7389,$,$); +#7393=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_28_78','Slings',#7389,$,$); +#7394=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_29','Fixed roof ventilators, terminals and accessories',#7304,$,$); +#7395=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_29_02','Abutment ventilators',#7394,$,$); +#7396=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_29_15','Combined eaves fascia grilles and ventilator trays',#7394,$,$); +#7397=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_29_30','Flat roof ventilators',#7394,$,$); +#7398=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_29_62','Plastics eaves underlay support',#7394,$,$); +#7399=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_29_64','Plastics rafter ventilator trays',#7394,$,$); +#7400=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_29_71','Roof ridge ventilator tiles',#7394,$,$); +#7401=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_29_72','Roof slope terminals',#7394,$,$); +#7402=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_29_73','Roof slope ventilator tiles',#7394,$,$); +#7403=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_29_74','Roof terminals',#7394,$,$); +#7404=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_29_75','Roof ventilator unit',#7394,$,$); +#7405=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_29_77','Rotary roof ventilators',#7394,$,$); +#7406=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_29_82','Strip ventilators',#7394,$,$); +#7407=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33','Gate surrounds and leaves',#7304,$,$); +#7408=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_02','Aluminium sheet gate leaves',#7407,$,$); +#7409=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_03','Aluminium vertical rail gate leaves',#7407,$,$); +#7410=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_11','Carbon steel expanded mesh gate leaves',#7407,$,$); +#7411=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_12','Carbon steel field gate leaves',#7407,$,$); +#7412=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_13','Carbon steel palisade gate leaves',#7407,$,$); +#7413=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_14','Carbon steel sheet gate leaves',#7407,$,$); +#7414=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_15','Carbon steel vertical section gate leaves',#7407,$,$); +#7415=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_16','Carbon steel welded mesh gate leaves',#7407,$,$); +#7416=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_33','Gate arches',#7407,$,$); +#7417=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_34','Glass infill gate leaves',#7407,$,$); +#7418=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_35','Glazing plastics gate leaves',#7407,$,$); +#7419=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_36','Hardwood field gate leaves',#7407,$,$); +#7420=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_37','Hardwood gate leaves',#7407,$,$); +#7421=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_38','Hardwood gate surrounds',#7407,$,$); +#7422=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_39','Hardwood palisade gate leaves',#7407,$,$); +#7423=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_52','Metal gate surrounds',#7407,$,$); +#7424=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_62','Plastics gate leaves',#7407,$,$); +#7425=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_63','Plywood sheet gate leaves',#7407,$,$); +#7426=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_78','Stainless steel expanded mesh gate leaves',#7407,$,$); +#7427=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_82','Stainless steel sheet gate leaves',#7407,$,$); +#7428=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_84','Stainless steel vertical rail gate leaves',#7407,$,$); +#7429=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_98','Wrought iron decorative gate leaves',#7407,$,$); +#7430=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_33_99','Wrought iron vertical rail gate leaves',#7407,$,$); +#7431=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34','Gates and turnstiles',#7304,$,$); +#7432=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_01','Aluminium full height turnstiles',#7431,$,$); +#7433=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_02','Aluminium gates',#7431,$,$); +#7434=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_03','Aluminium safety gates',#7431,$,$); +#7435=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_10','Canal lock gates',#7431,$,$); +#7436=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_11','Carbon steel bridle gates',#7431,$,$); +#7437=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_12','Carbon steel dog gates',#7431,$,$); +#7438=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_13','Carbon steel full height turnstiles',#7431,$,$); +#7439=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_14','Carbon steel gates',#7431,$,$); +#7440=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_15','Carbon steel half height turnstiles',#7431,$,$); +#7441=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_16','Carbon steel kissing gates',#7431,$,$); +#7442=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_17','Carbon steel motorbike inhibitors',#7431,$,$); +#7443=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_18','Carbon steel safety gates',#7431,$,$); +#7444=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_20','Composite gates',#7431,$,$); +#7445=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_30','Flood gates',#7431,$,$); +#7446=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_35','Glazed gates',#7431,$,$); +#7447=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_36','Hardwood bridle gates',#7431,$,$); +#7448=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_37','Hardwood dog gates',#7431,$,$); +#7449=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_38','Hardwood gates',#7431,$,$); +#7450=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_39','Hardwood kissing gates',#7431,$,$); +#7451=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_40','Hardwood ladder stiles',#7431,$,$); +#7452=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_41','Hardwood post and rail stiles',#7431,$,$); +#7453=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_65','Plastics gates',#7431,$,$); +#7454=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_78','Stainless steel full height turnstiles',#7431,$,$); +#7455=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_80','Stainless steel gates',#7431,$,$); +#7456=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_88','Stainless steel half height turnstiles',#7431,$,$); +#7457=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_90','Stainless steel safety gates',#7431,$,$); +#7458=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_34_98','Wrought iron gates',#7431,$,$); +#7459=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_36','Hatches and access panels',#7304,$,$); +#7460=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_36_01','Access panels',#7459,$,$); +#7461=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_36_02','Aluminium access hatches',#7459,$,$); +#7462=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_36_11','Carbon steel access hatches',#7459,$,$); +#7463=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_36_30','Floor hatches',#7459,$,$); +#7464=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_36_50','Manual trapdoors',#7459,$,$); +#7465=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_36_74','Roof hatches',#7459,$,$); +#7466=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_36_76','Self-closing safety hatches',#7459,$,$); +#7467=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_36_78','Self-closing trapdoors',#7459,$,$); +#7468=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_36_80','Stainless steel access hatches',#7459,$,$); +#7469=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_36_96','Wall hatches',#7459,$,$); +#7470=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_46','Lift barriers',#7304,$,$); +#7471=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_46_46','Lift landing doorsets',#7470,$,$); +#7472=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_46_47','Lift landing frames',#7470,$,$); +#7473=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_46_48','Lift landing sills',#7470,$,$); +#7474=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_46_49','Lift platform barriers',#7470,$,$); +#7475=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_46_63','Platform lift landing doorsets and gates',#7470,$,$); +#7476=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48','Louvres and components',#7304,$,$); +#7477=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_02','Aluminium louvre blades',#7476,$,$); +#7478=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_03','Aluminium louvre frames',#7476,$,$); +#7479=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_04','Aluminium louvre panel units',#7476,$,$); +#7480=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_11','Carbon steel louvre blades',#7476,$,$); +#7481=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_12','Carbon steel louvre frames',#7476,$,$); +#7482=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_13','Carbon steel louvre panel units',#7476,$,$); +#7483=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_34','Glass louvre blades',#7476,$,$); +#7484=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_52','Mirror louvre units',#7476,$,$); +#7485=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_65','Plastic louvre blades',#7476,$,$); +#7486=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_77','Screening and ventilation access doors',#7476,$,$); +#7487=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_78','Screening and ventilation louvre support frames',#7476,$,$); +#7488=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_83','Stainless steel louvre blades',#7476,$,$); +#7489=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_84','Stainless steel louvre frames',#7476,$,$); +#7490=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_85','Stainless steel louvre panel units',#7476,$,$); +#7491=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_96','Wood louvre blades',#7476,$,$); +#7492=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_97','Wood louvre frames',#7476,$,$); +#7493=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_48_98','Wood louvre panel units',#7476,$,$); +#7494=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_57','Opening security and protection products',#7304,$,$); +#7495=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_57_04','Anti-burglar window bars',#7494,$,$); +#7496=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_57_07','Bird guards',#7494,$,$); +#7497=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_57_08','Bird guard mesh',#7494,$,$); +#7498=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_57_28','Escalator shutters',#7494,$,$); +#7499=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_57_29','Firebreak shutters',#7494,$,$); +#7500=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_57_40','Insect guard mesh',#7494,$,$); +#7501=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_57_41','Insect guards',#7494,$,$); +#7502=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_57_58','Overhead ventilators',#7494,$,$); +#7503=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_57_76','Security shutters',#7494,$,$); +#7504=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_57_77','Security window screens',#7494,$,$); +#7505=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_58','Operable roof ventilators',#7304,$,$); +#7506=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_58_50','Manual control glazed roof ventilators',#7505,$,$); +#7507=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_58_88','Thermostatic control glazed roof ventilators',#7505,$,$); +#7508=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_59','Operable vehicular barriers',#7304,$,$); +#7509=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_59_11','Cantilevered sliding beam vehicular barriers',#7508,$,$); +#7510=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_59_38','Height restrictors',#7508,$,$); +#7511=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_59_39','Horizontal swing vehicular barriers',#7508,$,$); +#7512=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_59_72','Rising arm vehicular barriers',#7508,$,$); +#7513=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_59_79','Sliding vehicular barriers',#7508,$,$); +#7514=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_60','Passenger boarding bridges',#7304,$,$); +#7515=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_60_03','Apron drive passenger boarding bridges',#7514,$,$); +#7516=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_60_15','Commuter passenger boarding bridges',#7514,$,$); +#7517=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_60_56','Noseloader passenger boarding bridges',#7514,$,$); +#7518=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_60_80','Ship boarding gangways',#7514,$,$); +#7519=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_60_87','T bridge passenger boarding bridges',#7514,$,$); +#7520=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_61','Pavement and floorlight and venting products',#7304,$,$); +#7521=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_61_32','Glazed floorlight panels',#7520,$,$); +#7522=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_61_33','Glazed lift-out floorlight access panel',#7520,$,$); +#7523=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_61_34','Glazed lift-out access pavement light panels',#7520,$,$); +#7524=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_61_35','Glazed pavement light panels',#7520,$,$); +#7525=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_61_36','Glazed smoke venting panels',#7520,$,$); +#7526=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_61_57','Non-glazed smoke venting panels',#7520,$,$); +#7527=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_71','Refuse and linen chute inlets and openings',#7304,$,$); +#7528=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_71_12','Chute automatic fire doors',#7527,$,$); +#7529=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_71_13','Chute door interlocks',#7527,$,$); +#7530=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_71_21','Refuse chute discharge outlets',#7527,$,$); +#7531=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_71_22','Refuse chute doorsets',#7527,$,$); +#7532=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_71_23','Refuse chute hoppers',#7527,$,$); +#7533=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_71_46','Linen chute discharge outlets',#7527,$,$); +#7534=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_71_47','Linen chute doorsets',#7527,$,$); +#7535=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_71_48','Linen chute hoppers',#7527,$,$); +#7536=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72','Rooflights',#7304,$,$); +#7537=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_17','Continuous rooflights',#7536,$,$); +#7538=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_21','Daylight pipes',#7536,$,$); +#7539=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_24','Dormers',#7536,$,$); +#7540=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_25','Double glazed light pipe diffusers',#7536,$,$); +#7541=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_30','Factory-assembled insulating rooflights (FAIRs)',#7536,$,$); +#7542=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_31','Framed rooflights',#7536,$,$); +#7543=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_33','Glazed lift-out rooflight access panels',#7536,$,$); +#7544=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_34','Glazed rooflight panels',#7536,$,$); +#7545=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_42','Individual rooflights',#7536,$,$); +#7546=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_46','Lantern lights',#7536,$,$); +#7547=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_48','Light reflectors (motorized)',#7536,$,$); +#7548=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_57','North lights',#7536,$,$); +#7549=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_77','Skylights',#7536,$,$); +#7550=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_72_94','Ventilating light pipe diffusers',#7536,$,$); +#7551=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_84','Shutters and grilles',#7304,$,$); +#7552=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_84_30','Fire-resisting roller shutters',#7551,$,$); +#7553=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_84_72','Roller grilles',#7551,$,$); +#7554=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_84_73','Roller shutters',#7551,$,$); +#7555=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_94','Ventilation grilles',#7304,$,$); +#7556=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_94_04','Air ventilation grilles',#7555,$,$); +#7557=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_94_06','Air transfer grilles',#7555,$,$); +#7558=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_94_26','Eaves fascia grilles',#7555,$,$); +#7559=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_94_31','Fire-resisting air transfer grilles',#7555,$,$); +#7560=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_94_32','Fire-resisting air transfer grilles with smoke shutters',#7555,$,$); +#7561=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_94_78','Soffit grilles',#7555,$,$); +#7562=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_94_90','Trickle vents',#7555,$,$); +#7563=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_96','Wall venting products',#7304,$,$); +#7564=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_96_11','Cavity ventilators',#7563,$,$); +#7565=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_96_33','Gas venting grilles',#7563,$,$); +#7566=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_96_35','Ground-level vent outlets',#7563,$,$); +#7567=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_96_92','Ventilation ducts',#7563,$,$); +#7568=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_96_93','Ventilation gratings',#7563,$,$); +#7569=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_96_96','Wall vent outlets',#7563,$,$); +#7570=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_97','Window panels',#7304,$,$); +#7571=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_97_16','Glazed security window panels',#7570,$,$); +#7572=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_97_80','Speak through units',#7570,$,$); +#7573=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_97_90','Transaction units',#7570,$,$); +#7574=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_97_94','Vision panels',#7570,$,$); +#7575=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_98','Window units',#7304,$,$); +#7576=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_98_02','Aluminium window units',#7575,$,$); +#7577=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_98_03','Aluminium frame roof window units',#7575,$,$); +#7578=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_98_15','Composite window units',#7575,$,$); +#7579=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_98_34','Glass louvre window units',#7575,$,$); +#7580=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_98_72','Rigid polyurethane frame roof window units',#7575,$,$); +#7581=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_98_83','Steel window units',#7575,$,$); +#7582=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_98_84','Steel frame roof window units',#7575,$,$); +#7583=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_98_92','Unplasticized polyvinyl chloride (PVC-U) window units',#7575,$,$); +#7584=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_98_93','Unplasticized polyvinyl chloride (PVC-U) roof window units',#7575,$,$); +#7585=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_98_96','Wood window units',#7575,$,$); +#7586=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_98_97','Wood frame roof window units',#7575,$,$); +#7587=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_99','Window walls',#7304,$,$); +#7588=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_99_02','Aluminium window walls',#7587,$,$); +#7589=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_99_15','Composite window walls',#7587,$,$); +#7590=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_99_83','Steel window walls',#7587,$,$); +#7591=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_99_92','Unplasticized polyvinylchloride (PVC-U) window walls',#7587,$,$); +#7592=IFCCLASSIFICATIONREFERENCE($,'Pr_30_59_99_96','Wood window walls',#7587,$,$); +#7593=IFCCLASSIFICATIONREFERENCE($,'Pr_35','Covering and finishing products',#4923,$,$); +#7594=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31','Formless covering and finish products',#7593,$,$); +#7595=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05','Asphalt, bitumen and resin mixtures',#7594,$,$); +#7596=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_03','Asphalt concrete (AC) base courses',#7595,$,$); +#7597=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_04','Asphalt concrete (AC) binder courses',#7595,$,$); +#7598=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_05','Asphalt concrete (AC) surface courses',#7595,$,$); +#7599=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_07','Bitumen coated chippings',#7595,$,$); +#7600=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_08','Bitumen emulsion and glass fibre sandwich matrices',#7595,$,$); +#7601=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_10','Bonded grit surfacings',#7595,$,$); +#7602=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_19','Cut-back and fluxed bitumen binders',#7595,$,$); +#7603=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_36','Hard paving-grade bitumen',#7595,$,$); +#7604=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_37','Hot-applied oxidized bitumen coatings',#7595,$,$); +#7605=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_38','Hot-rolled asphalt (HRA) base courses',#7595,$,$); +#7606=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_39','Hot-rolled asphalt (HRA) binder courses',#7595,$,$); +#7607=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_40','Hot-rolled asphalt (HRA) surface courses and slurries',#7595,$,$); +#7608=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_42','Impervious textured sports surfacings',#7595,$,$); +#7609=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_50','Mastic asphalt (MA) surface courses',#7595,$,$); +#7610=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_60','Paving-grade bitumens',#7595,$,$); +#7611=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_64','Polyurethane-bound ethylene propylene diene monomer (EPDM) rubber crumb surfacings',#7595,$,$); +#7612=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_65','Porous asphalt concrete (PAC) surface courses',#7595,$,$); +#7613=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_70','Resin-bonded aggregate surfacings',#7595,$,$); +#7614=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_71','Resin-bound mixed aggregate surfacings',#7595,$,$); +#7615=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_72','Roofing, tanking and flooring mastic asphalt (MA)',#7595,$,$); +#7616=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_75','Sand asphalt',#7595,$,$); +#7617=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_83','Stone mastic asphalt (SMA) binder courses',#7595,$,$); +#7618=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_84','Stone mastic asphalt (SMA) regulating courses',#7595,$,$); +#7619=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_05_85','Stone mastic asphalt (SMA) surface courses',#7595,$,$); +#7620=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06','Bedding and underlay compounds',#7594,$,$); +#7621=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_12','Cementitious levelling screed mixes',#7620,$,$); +#7622=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_15','Concrete (granolithic) wearing screed mixes',#7620,$,$); +#7623=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_28','Fibre-reinforced levelling screed mixes',#7620,$,$); +#7624=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_29','Fine concrete levelling screed mixes',#7620,$,$); +#7625=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_31','Floor seals',#7620,$,$); +#7626=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_32','Flow applied flooring',#7620,$,$); +#7627=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_36','Heavy-duty flow-applied flooring',#7620,$,$); +#7628=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_37','Heavy-duty screed flooring',#7620,$,$); +#7629=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_38','High-build floor coatings',#7620,$,$); +#7630=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_47','Lightweight aggregate levelling screed mixes',#7620,$,$); +#7631=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_55','Multilayer flooring',#7620,$,$); +#7632=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_64','Polymer-modified levelling screed mixes',#7620,$,$); +#7633=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_65','Polymer-modified wearing screed mixes',#7620,$,$); +#7634=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_69','Quick-drying levelling screed mixes',#7620,$,$); +#7635=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_71','Ready-mixed levelling and wearing screeds',#7620,$,$); +#7636=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_72','Ready-mixed self-smoothing calcium sulfate screeds',#7620,$,$); +#7637=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_73','Ready-mixed trowelled calcium sulfate screeds',#7620,$,$); +#7638=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_77','Screed flooring',#7620,$,$); +#7639=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_78','Self-smoothing levelling screed mixes',#7620,$,$); +#7640=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_79','Self-smoothing wearing screed mixes',#7620,$,$); +#7641=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_06_80','Smoothing and levelling underlay compounds',#7620,$,$); +#7642=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22','Decorative coatings',#7594,$,$); +#7643=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_02','Aluminium paints',#7642,$,$); +#7644=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_12','Casein paints',#7642,$,$); +#7645=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_13','Cement paints',#7642,$,$); +#7646=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_15','Concrete finishing coats',#7642,$,$); +#7647=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_16','Concrete flash coats',#7642,$,$); +#7648=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_17','Concrete floor dyes',#7642,$,$); +#7649=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_18','Concrete floor paints',#7642,$,$); +#7650=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_19','Concrete stains',#7642,$,$); +#7651=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_23','Distemper',#7642,$,$); +#7652=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_37','High pigment waterborne paint',#7642,$,$); +#7653=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_47','Limewashes',#7642,$,$); +#7654=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_52','Micaceous iron oxide paints',#7642,$,$); +#7655=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_54','Multi-colour coatings',#7642,$,$); +#7656=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_55','Multi-colour finish spatter coatings',#7642,$,$); +#7657=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_58','Oil-bound distempers',#7642,$,$); +#7658=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_62','Plant oil paints',#7642,$,$); +#7659=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_64','Plastic texture paints',#7642,$,$); +#7660=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_72','Resin-based breathable masonry paints',#7642,$,$); +#7661=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_74','Semi-transparent timber dyes',#7642,$,$); +#7662=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_75','Semi-transparent timber oils',#7642,$,$); +#7663=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_76','Semi-transparent timber stains',#7642,$,$); +#7664=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_77','Silicate-based masonry coatings',#7642,$,$); +#7665=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_79','Solvent-based finishing coats',#7642,$,$); +#7666=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_80','Solvent-borne gloss finishes',#7642,$,$); +#7667=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_81','Solvent-borne masonry paints',#7642,$,$); +#7668=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_82','Solvent-borne matt and flat finishes',#7642,$,$); +#7669=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_83','Solvent-borne mid-sheen finishes',#7642,$,$); +#7670=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_87','Tallow lime washes',#7642,$,$); +#7671=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_95','Waterborne gloss finishes',#7642,$,$); +#7672=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_96','Waterborne masonry paints',#7642,$,$); +#7673=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_97','Waterborne matt and flat finishes',#7642,$,$); +#7674=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_22_98','Waterborne mid-sheen finishes',#7642,$,$); +#7675=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64','Plasters and renders',#7594,$,$); +#7676=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_01','Acrylic plasters',#7675,$,$); +#7677=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_02','Acrylic renders',#7675,$,$); +#7678=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_07','Biocidal renders',#7675,$,$); +#7679=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_08','Bonding plasters',#7675,$,$); +#7680=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_09','Browning plasters',#7675,$,$); +#7681=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_12','Cementitious renders',#7675,$,$); +#7682=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_14','Clay plasters',#7675,$,$); +#7683=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_29','Factory mixed plasters',#7675,$,$); +#7684=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_31','Fibrous plasters',#7675,$,$); +#7685=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_32','Finish plasters',#7675,$,$); +#7686=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_35','Gypsum plasters',#7675,$,$); +#7687=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_42','Insulating plasters',#7675,$,$); +#7688=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_47','Lime plasters',#7675,$,$); +#7689=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_48','Lime renders',#7675,$,$); +#7690=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_64','Polymer plasters',#7675,$,$); +#7691=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_65','Polymer-modified renders',#7675,$,$); +#7692=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_67','Projection plasters',#7675,$,$); +#7693=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_70','Render-grade resins',#7675,$,$); +#7694=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_71','Renovating plasters',#7675,$,$); +#7695=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_76','Scagliola',#7675,$,$); +#7696=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_77','Silicone renders',#7675,$,$); +#7697=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_80','Solid cast plasters',#7675,$,$); +#7698=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_84','Squash court plasters',#7675,$,$); +#7699=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_85','Stucco',#7675,$,$); +#7700=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_86','Synthetic plasters',#7675,$,$); +#7701=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_98','X-ray undercoat plasters',#7675,$,$); +#7702=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_64_99','Zinc oxychloride plasters',#7675,$,$); +#7703=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65','Preparation materials, fillers and stoppers',#7594,$,$); +#7704=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_01','Abrasives',#7703,$,$); +#7705=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_02','Abrasive blocks',#7703,$,$); +#7706=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_12','Cement and grout fillers',#7703,$,$); +#7707=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_13','Chemical fillers',#7703,$,$); +#7708=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_20','Decorator\X2\2019\X0\s caulks',#7703,$,$); +#7709=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_21','Decorator\X2\2019\X0\s flexible fillers',#7703,$,$); +#7710=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_22','Degreaser solutions',#7703,$,$); +#7711=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_23','Detergent solutions',#7703,$,$); +#7712=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_24','Dry air pressured abrasives',#7703,$,$); +#7713=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_25','Dry air pressured micro-abrasives',#7703,$,$); +#7714=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_26','Dusting powders',#7703,$,$); +#7715=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_27','Efflorescence control compounds',#7703,$,$); +#7716=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_28','End grain sealers',#7703,$,$); +#7717=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_29','Fine surface fillers',#7703,$,$); +#7718=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_30','Finishing compounds',#7703,$,$); +#7719=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_31','Fire-resistant fillers',#7703,$,$); +#7720=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_34','Gypsum-based bedding compounds',#7703,$,$); +#7721=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_50','Masonry stabilizers',#7703,$,$); +#7722=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_74','Rust removers',#7703,$,$); +#7723=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_79','Stoppers',#7703,$,$); +#7724=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_80','Stopper fillers',#7703,$,$); +#7725=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_82','Surface fillers',#7703,$,$); +#7726=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_95','Wax-based fillers',#7703,$,$); +#7727=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_96','Wet air pressured abrasives',#7703,$,$); +#7728=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_97','Wetting agents',#7703,$,$); +#7729=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_65_98','Wood knotting solutions',#7703,$,$); +#7730=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66','Preparatory coatings',#7594,$,$); +#7731=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_02','Adhesion promoters',#7730,$,$); +#7732=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_03','Alkali-resisting primers',#7730,$,$); +#7733=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_07','Basecoat stains',#7730,$,$); +#7734=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_08','Bitumen primers',#7730,$,$); +#7735=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_09','Bonding coats',#7730,$,$); +#7736=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_15','Combined barrier and bonding coats',#7730,$,$); +#7737=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_16','Concrete curing coatings',#7730,$,$); +#7738=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_21','Debonding compounds',#7730,$,$); +#7739=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_22','Dressing compounds',#7730,$,$); +#7740=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_26','Etching primers',#7730,$,$); +#7741=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_30','Floor covering primers',#7730,$,$); +#7742=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_34','Gilding basecoats',#7730,$,$); +#7743=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_50','Mastic asphalt (MA) primers',#7730,$,$); +#7744=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_51','Metallic lead primers',#7730,$,$); +#7745=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_52','Modified bitumen primers',#7730,$,$); +#7746=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_53','Mordant solutions',#7730,$,$); +#7747=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_55','Multi-colour finish basecoats',#7730,$,$); +#7748=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_57','Non-bituminous primers',#7730,$,$); +#7749=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_60','Paving primers',#7730,$,$); +#7750=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_62','Plaster primers',#7730,$,$); +#7751=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_63','Plasterboard primers',#7730,$,$); +#7752=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_67','Primer-sealers',#7730,$,$); +#7753=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_68','Primer-undercoats',#7730,$,$); +#7754=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_70','Reinforcement treatments',#7730,$,$); +#7755=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_71','Resin coating primers',#7730,$,$); +#7756=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_75','Sanded primers',#7730,$,$); +#7757=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_76','Silicate-based primers',#7730,$,$); +#7758=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_77','Sealant primers',#7730,$,$); +#7759=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_78','Slip plane bituminous emulsion paint primers',#7730,$,$); +#7760=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_80','Solvent-borne basecoats',#7730,$,$); +#7761=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_81','Solvent-borne metal primers',#7730,$,$); +#7762=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_82','Solvent-borne undercoats',#7730,$,$); +#7763=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_83','Solvent-borne wood primers',#7730,$,$); +#7764=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_88','Thinners',#7730,$,$); +#7765=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_92','Universal primers',#7730,$,$); +#7766=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_94','Water-based acrylic primers',#7730,$,$); +#7767=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_95','Waterborne basecoats',#7730,$,$); +#7768=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_96','Waterborne metal primers',#7730,$,$); +#7769=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_97','Waterborne thinned undercoats',#7730,$,$); +#7770=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_98','Waterborne wood primers',#7730,$,$); +#7771=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_66_99','Waterborne undercoats',#7730,$,$); +#7772=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67','Preservative, additives and fire-retardant treatments',#7594,$,$); +#7773=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_01','Acrylic retarder additives',#7772,$,$); +#7774=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_07','Borate pellet and rod preservatives',#7772,$,$); +#7775=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_08','Boron compound preservatives',#7772,$,$); +#7776=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_14','Clear flame-retardant finishes',#7772,$,$); +#7777=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_15','Copper-organic preservatives',#7772,$,$); +#7778=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_24','Dry interior fire-retardant solutions',#7772,$,$); +#7779=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_34','Glycol-borne preservatives',#7772,$,$); +#7780=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_37','House longhorn beetle timber treatments',#7772,$,$); +#7781=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_39','Humidity-resistant fire-retardant solutions',#7772,$,$); +#7782=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_41','Insecticidal paint additives',#7772,$,$); +#7783=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_42','Interior fire-retardant solutions',#7772,$,$); +#7784=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_46','Latex retarder additives',#7772,$,$); +#7785=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_47','Leach-resistant fire-retardant solutions',#7772,$,$); +#7786=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_52','Micro-emulsion-borne preservatives',#7772,$,$); +#7787=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_59','Organic solvent-borne preservatives',#7772,$,$); +#7788=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_88','Thatch fire-preservative treatments',#7772,$,$); +#7789=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_89','Thatch fire-retardant treatments',#7772,$,$); +#7790=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_96','Waterborne preservatives',#7772,$,$); +#7791=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_97','Water based micro-emulsion preservatives',#7772,$,$); +#7792=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_67_98','Water-based organic preservatives',#7772,$,$); +#7793=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68','Protective coatings',#7594,$,$); +#7794=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_01','Acrylic-based waterproof coatings',#7793,$,$); +#7795=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_02','Anionic bitumen emulsions',#7793,$,$); +#7796=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_03','Anodizing',#7793,$,$); +#7797=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_04','Anti-carbonation coatings',#7793,$,$); +#7798=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_05','Anti-graffiti coatings',#7793,$,$); +#7799=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_06','Barrier coatings',#7793,$,$); +#7800=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_07','Bitumen-based black coatings',#7793,$,$); +#7801=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_09','Bitumen emulsion waterproof coatings',#7793,$,$); +#7802=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_10','Black bitumen coatings',#7793,$,$); +#7803=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_11','Cationic bitumen emulsions',#7793,$,$); +#7804=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_12','Cellulose coatings',#7793,$,$); +#7805=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_13','Chrome plating',#7793,$,$); +#7806=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_14','Clear floor varnishes',#7793,$,$); +#7807=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_15','Clear varnishes',#7793,$,$); +#7808=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_16','Cold-applied bitumen solutions',#7793,$,$); +#7809=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_17','Cold-applied polymer-modified bitumen waterproof coatings',#7793,$,$); +#7810=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_18','Concrete polishes',#7793,$,$); +#7811=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_19','Copper plating',#7793,$,$); +#7812=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_21','Cork tile polyurethane (PUR) varnishes',#7793,$,$); +#7813=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_27','Epoxy resin coatings',#7793,$,$); +#7814=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_28','Epoxy underwater coatings',#7793,$,$); +#7815=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_29','Flame-retardant coatings',#7793,$,$); +#7816=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_31','Floor dyes',#7793,$,$); +#7817=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_32','Floor polishes',#7793,$,$); +#7818=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_33','Fungicidal coatings',#7793,$,$); +#7819=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_34','Galvanized coatings',#7793,$,$); +#7820=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_35','Gold plating',#7793,$,$); +#7821=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_36','Hard wax oils',#7793,$,$); +#7822=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_37','Heat-resisting coatings',#7793,$,$); +#7823=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_38','Hot-applied polymer-modified bitumen waterproof coatings',#7793,$,$); +#7824=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_39','Hot dip galvanizings',#7793,$,$); +#7825=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_40','Hygienic coatings',#7793,$,$); +#7826=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_43','Intumescent protective coatings',#7793,$,$); +#7827=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_46','Lacquers',#7793,$,$); +#7828=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_47','Liquid tanking resins',#7793,$,$); +#7829=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_51','Mastic asphalt (MA) polishes',#7793,$,$); +#7830=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_52','Membrane walkway coatings',#7793,$,$); +#7831=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_55','Multi-colour finish glaze coats',#7793,$,$); +#7832=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_60','Patination oils',#7793,$,$); +#7833=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_62','Polymer resin waterproof coatings',#7793,$,$); +#7834=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_63','Polyester resin waterproof coatings',#7793,$,$); +#7835=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_64','Polyurethane (PUR) waterproof coatings',#7793,$,$); +#7836=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_65','Polyvinylidene fluoride (PVDF) coatings',#7793,$,$); +#7837=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_66','Powder coatings',#7793,$,$); +#7838=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_69','Red oxide paints',#7793,$,$); +#7839=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_70','Resin floor coatings',#7793,$,$); +#7840=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_72','Sacrificial anti-corrosion coatings',#7793,$,$); +#7841=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_74','Sherardized coatings',#7793,$,$); +#7842=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_75','Silver plating',#7793,$,$); +#7843=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_79','Sprayed monolithic coating finishing coats',#7793,$,$); +#7844=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_80','Solvent-free waterproof coatings',#7793,$,$); +#7845=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_81','Solar reflective coatings',#7793,$,$); +#7846=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_82','Solar reflective anti-corrosion coatings',#7793,$,$); +#7847=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_83','Spray-applied fireproof coatings',#7793,$,$); +#7848=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_84','Spray-applied thermal insulation',#7793,$,$); +#7849=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_85','Steel fence powder coatings',#7793,$,$); +#7850=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_86','Surface preservation products',#7793,$,$); +#7851=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_87','Tar-based black coatings',#7793,$,$); +#7852=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_88','Thermoplastic block copolymer waterproof coatings',#7793,$,$); +#7853=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_96','Water-dispersible polymer waterproof coatings',#7793,$,$); +#7854=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_97','Water repellents',#7793,$,$); +#7855=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_98','Yacht varnishes',#7793,$,$); +#7856=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_68_99','Zinc plating',#7793,$,$); +#7857=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77','Surface sealers',#7594,$,$); +#7858=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_05','Anti-graffiti sealers',#7857,$,$); +#7859=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_08','Bitumen-based impregnating sealers',#7857,$,$); +#7860=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_12','Cement-based screed surface sealers',#7857,$,$); +#7861=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_15','Concrete sealers',#7857,$,$); +#7862=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_16','Cork flooring sealers',#7857,$,$); +#7863=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_24','Dry shake finish sealers',#7857,$,$); +#7864=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_25','Dustproofing sealers',#7857,$,$); +#7865=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_30','Floor surface sealers',#7857,$,$); +#7866=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_42','Intumescent coating sealers',#7857,$,$); +#7867=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_46','Liquid applied membranes',#7857,$,$); +#7868=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_50','Mastic asphalt (MA) oil-resistant sealers',#7857,$,$); +#7869=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_60','Paving sealers and stabilizers',#7857,$,$); +#7870=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_72','Resin floor sealers',#7857,$,$); +#7871=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_76','Sealers',#7857,$,$); +#7872=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_84','Sprayed monolithic coating sealers',#7857,$,$); +#7873=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_92','Ultraviolet (UV)-resistant sealers',#7857,$,$); +#7874=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_77_96','Wood floor sealers',#7857,$,$); +#7875=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85','Specialist coatings',#7594,$,$); +#7876=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_02','Acoustic chute coatings',#7875,$,$); +#7877=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_03','Anti-climb paints',#7875,$,$); +#7878=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_04','Anti-slip floor coatings',#7875,$,$); +#7879=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_05','Anti-static carpet treatments',#7875,$,$); +#7880=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_13','Chlorinated rubber road markings',#7875,$,$); +#7881=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_21','Damp proof coatings',#7875,$,$); +#7882=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_24','Dry rot paints',#7875,$,$); +#7883=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_26','Elastomeric paints',#7875,$,$); +#7884=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_27','Epoxy paint road markings',#7875,$,$); +#7885=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_29','Fluorescent paints',#7875,$,$); +#7886=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_35','Gilding leaf',#7875,$,$); +#7887=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_36','Gilding size',#7875,$,$); +#7888=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_46','Light duty road markings',#7875,$,$); +#7889=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_47','Line marking paints',#7875,$,$); +#7890=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_48','Luminous paints',#7875,$,$); +#7891=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_51','Metallic wear resistant, low friction coatings',#7875,$,$); +#7892=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_60','Phosphorescent paints',#7875,$,$); +#7893=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_61','Polyurethane resin based paint',#7875,$,$); +#7894=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_62','Polyurethane (PUR) rubber spray surfaces',#7875,$,$); +#7895=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_65','Preformed road markings',#7875,$,$); +#7896=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_70','Radiator enamels',#7875,$,$); +#7897=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_72','Reflective coatings',#7875,$,$); +#7898=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_78','Slip plane bituminous emulsion paints',#7875,$,$); +#7899=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_80','Slip-resistant surface treatments',#7875,$,$); +#7900=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_81','Sound damping coatings',#7875,$,$); +#7901=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_82','Surface hardeners',#7875,$,$); +#7902=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_88','Thermoplastic line markings',#7875,$,$); +#7903=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_90','Thermoplastic road markings',#7875,$,$); +#7904=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_94','Vitreous enamels',#7875,$,$); +#7905=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_96','Waterborne resin coatings',#7875,$,$); +#7906=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_97','Wear and abrasion resistant coating',#7875,$,$); +#7907=IFCCLASSIFICATIONREFERENCE($,'Pr_35_31_85_98','Wearing surface dry shake materials',#7875,$,$); +#7908=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57','Non-rigid sheet, mat and strip covering and finish products',#7593,$,$); +#7909=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11','Carpets, carpet tiles, coverings, underlays and mats',#7908,$,$); +#7910=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_05','Axminster carpets',#7909,$,$); +#7911=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_07','Bonded carpets',#7909,$,$); +#7912=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_08','Bonded carpet tiles',#7909,$,$); +#7913=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_11','Cellular plastics underlays',#7909,$,$); +#7914=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_13','Cellular rubber underlays',#7909,$,$); +#7915=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_15','Combined fibrous or non-fibrous underlays',#7909,$,$); +#7916=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_24','Dry felt paper interlays',#7909,$,$); +#7917=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_26','Entrance mats',#7909,$,$); +#7918=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_27','Ethylene propylene diene monomer (EPDM) rubber mats',#7909,$,$); +#7919=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_28','Exercise mats',#7909,$,$); +#7920=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_29','Flat needled carpet tiles',#7909,$,$); +#7921=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_30','Flat needled carpets',#7909,$,$); +#7922=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_31','Flocked carpets',#7909,$,$); +#7923=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_36','Hessian-faced cork underlays',#7909,$,$); +#7924=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_40','Impregnated fibrous underlays',#7909,$,$); +#7925=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_45','Knitted carpets',#7909,$,$); +#7926=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_46','Loose-laid cushion matting',#7909,$,$); +#7927=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_47','Loose-laid fatigue matting',#7909,$,$); +#7928=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_49','Loose-laid matting',#7909,$,$); +#7929=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_56','Needled felt underlays',#7909,$,$); +#7930=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_57','Needled pile carpet tiles',#7909,$,$); +#7931=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_58','Needled pile carpets',#7909,$,$); +#7932=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_62','Pile carpet tiles',#7909,$,$); +#7933=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_64','Pile carpets',#7909,$,$); +#7934=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_66','Polybutyl teraphthalate (PBT) bristle mats',#7909,$,$); +#7935=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_68','Polyvinyl chloride (PVC) bristle mats',#7909,$,$); +#7936=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_72','Reed mats',#7909,$,$); +#7937=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_74','Rubber crumb underlays',#7909,$,$); +#7938=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_85','Synthetic grass surfaces',#7909,$,$); +#7939=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_91','Tufted carpets',#7909,$,$); +#7940=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_11_97','Wilton carpets',#7909,$,$); +#7941=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_15','Composite surfacing and underlay products',#7908,$,$); +#7942=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_15_40','In situ polymer shock absorption layers',#7941,$,$); +#7943=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_15_42','Interlocking shock absorption panels',#7941,$,$); +#7944=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_15_75','Sand enveloped shock absorption layers',#7941,$,$); +#7945=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_15_80','Sheet format shock absorption layers',#7941,$,$); +#7946=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22','Decorative papers and roll coverings',#7908,$,$); +#7947=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_08','Border papers',#7946,$,$); +#7948=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_15','Cork roll coverings',#7946,$,$); +#7949=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_38','Heavy-duty roll coverings',#7946,$,$); +#7950=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_42','Ingrain roll coverings',#7946,$,$); +#7951=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_46','Linen-backed lining papers',#7946,$,$); +#7952=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_48','Lining papers',#7946,$,$); +#7953=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_51','Metal foil roll coverings',#7946,$,$); +#7954=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_52','Metallic effect roll coverings',#7946,$,$); +#7955=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_53','Metallized roll coverings',#7946,$,$); +#7956=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_54','Mural roll coverings',#7946,$,$); +#7957=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_58','Non-woven lining papers',#7946,$,$); +#7958=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_60','Paper roll coverings',#7946,$,$); +#7959=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_72','Relief roll coverings',#7946,$,$); +#7960=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_88','Textile roll coverings',#7946,$,$); +#7961=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_90','Textured effect roll coverings',#7946,$,$); +#7962=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_22_95','Vinyl roll coverings',#7946,$,$); +#7963=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71','Resilient floor coverings',#7908,$,$); +#7964=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_02','Agglomerated composition cork tiles',#7963,$,$); +#7965=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_04','Agglomerated composition cork tiles with polyvinyl chloride (PVC) wearing layer',#7963,$,$); +#7966=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_12','Composite sheets',#7963,$,$); +#7967=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_13','Composite rubber tiles',#7963,$,$); +#7968=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_14','Composite tiles',#7963,$,$); +#7969=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_15','Cork linoleum (cork carpet) sheets',#7963,$,$); +#7970=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_17','Cork-backed linoleum sheets',#7963,$,$); +#7971=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_19','Cork-backed polyvinyl chloride (PVC) sheets',#7963,$,$); +#7972=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_20','Cork-backed polyvinyl chloride (PVC) tiles',#7963,$,$); +#7973=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_22','Cork sheets',#7963,$,$); +#7974=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_23','Cork tiles',#7963,$,$); +#7975=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_25','Ethylene propylene diene monomer (EPDM) rubber tiles',#7963,$,$); +#7976=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_26','Expanded (cushioned) polyvinyl chloride (PVC) sheets',#7963,$,$); +#7977=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_27','Expanded (cushioned) polyvinyl chloride (PVC) tiles',#7963,$,$); +#7978=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_28','Filled fibrous-backed polyvinyl chloride (PVC) sheets',#7963,$,$); +#7979=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_30','Floor surface coating resins',#7963,$,$); +#7980=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_31','Foam-backed linoleum sheets',#7963,$,$); +#7981=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_32','Foam backed polyvinyl chloride (PVC) sheets',#7963,$,$); +#7982=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_33','Foam backed polyvinyl chloride (PVC) tiles',#7963,$,$); +#7983=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_34','Foam-backed smooth rubber sheets',#7963,$,$); +#7984=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_35','Granular rubber sheets',#7963,$,$); +#7985=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_36','Granular rubber tiles',#7963,$,$); +#7986=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_37','Hammered rubber tiles',#7963,$,$); +#7987=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_43','Jute or polyester felt-backed polyvinyl chloride (PVC) sheets',#7963,$,$); +#7988=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_44','Jute or polyester felt-backed polyvinyl chloride (PVC) tiles',#7963,$,$); +#7989=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_46','Linoleum sheets',#7963,$,$); +#7990=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_49','Linoleum tiles',#7963,$,$); +#7991=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_60','Particle-based enhanced wet area polyvinyl chloride (PVC) sheets',#7963,$,$); +#7992=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_61','Particle-based enhanced slip-resistant polyvinyl chloride (PVC) sheets',#7963,$,$); +#7993=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_62','Particle-based enhanced slip-resistant polyvinyl chloride (PVC) tiles',#7963,$,$); +#7994=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_67','Polyvinyl chloride (PVC) sheets',#7963,$,$); +#7995=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_68','Polyvinyl chloride (PVC) tiles',#7963,$,$); +#7996=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_72','Relief rubber sheets',#7963,$,$); +#7997=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_73','Relief rubber tiles',#7963,$,$); +#7998=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_74','Rubber mats and sheets',#7963,$,$); +#7999=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_75','Rubber tiles',#7963,$,$); +#8000=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_76','Semi-flexible polyvinyl chloride (PVC) tiles',#7963,$,$); +#8001=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_80','Smooth rubber sheets',#7963,$,$); +#8002=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_84','Smooth rubber tiles',#7963,$,$); +#8003=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_86','Solid rubber sheets',#7963,$,$); +#8004=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_71_87','Stabilizing underlays',#7963,$,$); +#8005=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_88','Textiles',#7908,$,$); +#8006=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_88_16','Cotton textiles',#8005,$,$); +#8007=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_88_46','Linen textiles',#8005,$,$); +#8008=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_88_97','Woollen textiles',#8005,$,$); +#8009=IFCCLASSIFICATIONREFERENCE($,'Pr_35_57_88_98','Wool-nylon textiles',#8005,$,$); +#8010=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90','Trim products',#7593,$,$); +#8011=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_07','Beads, stops and fillets',#8010,$,$); +#8012=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_07_04','Angle fillets',#8011,$,$); +#8013=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_07_08','Bitumen impregnated fibreboard fillets',#8011,$,$); +#8014=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_07_15','Copper cames',#8011,$,$); +#8015=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_07_24','Dry lining beads',#8011,$,$); +#8016=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_07_33','Glazing beads',#8011,$,$); +#8017=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_07_47','Lead cames',#8011,$,$); +#8018=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_07_63','Plaster beads',#8011,$,$); +#8019=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_07_72','Render beads',#8011,$,$); +#8020=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_07_73','Render stops',#8011,$,$); +#8021=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_07_88','Thin-coat plaster beads',#8011,$,$); +#8022=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_07_89','Timber fillets',#8011,$,$); +#8023=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_09','Bridge expansion joints',#8010,$,$); +#8024=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_09_11','Cantilever expansion comb or tooth joints',#8023,$,$); +#8025=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_09_27','Elastomeric expansion joint in metal runners',#8023,$,$); +#8026=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_09_28','Elastomeric pads',#8023,$,$); +#8027=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_09_71','Reinforced elastomeric expansion joints',#8023,$,$); +#8028=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_09_85','Supported expansion joints',#8023,$,$); +#8029=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15','Concrete construction joint accessories',#8010,$,$); +#8030=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_04','Armoured joints',#8029,$,$); +#8031=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_08','Bottom-of-slab plastics crack inducers',#8029,$,$); +#8032=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_11','Carbon steel arris armourings',#8029,$,$); +#8033=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_12','Carbon steel shear load connectors',#8029,$,$); +#8034=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_13','Carbon steel strip crack inducers',#8029,$,$); +#8035=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_14','Centrally-placed rubber flexible waterstops',#8029,$,$); +#8036=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_15','Centrally-placed polyvinyl chloride (PVC) elastomer flexible waterstops',#8029,$,$); +#8037=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_16','Centrally-placed unplasticized polyvinyl chloride (PVC-U) flexible waterstops',#8029,$,$); +#8038=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_19','Coated metal waterstops',#8029,$,$); +#8039=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_37','Headed stud shear connectors',#8029,$,$); +#8040=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_42','Injectable hose waterstops',#8029,$,$); +#8041=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_48','Loop connectors',#8029,$,$); +#8042=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_63','Plastics strip crack inducers',#8029,$,$); +#8043=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_72','Rubber flexible waterstops',#8029,$,$); +#8044=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_74','Rubber hydrophilic waterstops',#8029,$,$); +#8045=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_77','Shrinkage tube crack inducers',#8029,$,$); +#8046=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_82','Stainless steel arris armourings',#8029,$,$); +#8047=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_83','Stainless steel shear load connectors',#8029,$,$); +#8048=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_84','Stainless steel strip crack inducers',#8029,$,$); +#8049=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_85','Surface mounted polyvinyl chloride (PVC) flexible waterstops',#8029,$,$); +#8050=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_86','Synthetic elastomer hydrophilic waterstops',#8029,$,$); +#8051=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_88','Thermal break shear load connectors',#8029,$,$); +#8052=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_15_89','Thermal break connection plates',#8029,$,$); +#8053=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_22','Dividing and edge strips',#8010,$,$); +#8054=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_22_36','Hardwood edgings',#8053,$,$); +#8055=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_22_51','Metal angle edgings',#8053,$,$); +#8056=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_22_52','Metal edgings',#8053,$,$); +#8057=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_22_63','Plastics edgings',#8053,$,$); +#8058=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_22_66','Preformed tiling strip joints',#8053,$,$); +#8059=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_22_72','Recycled plastics edgings',#8053,$,$); +#8060=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_22_80','Softwood edgings',#8053,$,$); +#8061=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_22_88','Timber grass edgings',#8053,$,$); +#8062=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_27','Expansion joints',#8010,$,$); +#8063=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_27_11','Chloroprene and aluminium expansion joints',#8062,$,$); +#8064=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_27_12','Chloroprene and copper expansion joints',#8062,$,$); +#8065=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_27_13','Chloroprene and lead expansion joints',#8062,$,$); +#8066=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_27_14','Chloroprene and stainless steel expansion joints',#8062,$,$); +#8067=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_27_15','Chloroprene and zinc expansion joints',#8062,$,$); +#8068=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28','External trims and sills',#8010,$,$); +#8069=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_02','Aluminium fascias',#8068,$,$); +#8070=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_04','Anti-climb security devices',#8068,$,$); +#8071=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_11','Carbon steel fascias',#8068,$,$); +#8072=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_15','Cover caps',#8068,$,$); +#8073=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_23','Double skin glass-reinforced plastics (GRP) components',#8068,$,$); +#8074=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_32','Glass-reinforced plastics (GRP) fa\X2\00E7\X0\ade components',#8068,$,$); +#8075=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_33','Glass-reinforced plastics (GRP) roof components',#8068,$,$); +#8076=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_36','Hardwood copings',#8068,$,$); +#8077=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_50','Membrane standing seam profiles',#8068,$,$); +#8078=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_51','Metal drip trims',#8068,$,$); +#8079=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_52','Metal finishing trims',#8068,$,$); +#8080=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_62','Plastics and composite material trim boards',#8068,$,$); +#8081=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_64','Polyvinyl chloride (PVC) standing seam profiles',#8068,$,$); +#8082=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_72','Roof membrane perimeter trims',#8068,$,$); +#8083=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_76','Single skin ribbed glass',#8068,$,$); +#8084=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_79','Softwood copings',#8068,$,$); +#8085=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_82','Stainless steel cappings and copings',#8068,$,$); +#8086=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_83','Stainless steel fascias',#8068,$,$); +#8087=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_84','Stainless steel undersills',#8068,$,$); +#8088=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_92','Unplasticized polyvinyl chloride (PVC-U) finishing trims',#8068,$,$); +#8089=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_93','Unplasticized polyvinyl chloride (PVC-U) sills',#8068,$,$); +#8090=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_95','Window sill boards',#8068,$,$); +#8091=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_96','Wood finishing trims',#8068,$,$); +#8092=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_28_97','Wood trim boards',#8068,$,$); +#8093=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_30','Flashings',#8010,$,$); +#8094=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_30_01','Aluminium flashings',#8093,$,$); +#8095=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_30_08','Bitumen-based flashings',#8093,$,$); +#8096=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_30_11','Carbon steel flashings',#8093,$,$); +#8097=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_30_15','Copper flashings',#8093,$,$); +#8098=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_30_18','Copper slates',#8093,$,$); +#8099=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_30_34','Glass-reinforced plastics (GRP) flashings',#8093,$,$); +#8100=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_30_46','Lead flashings',#8093,$,$); +#8101=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_30_47','Lead slates',#8093,$,$); +#8102=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_30_64','Polyethylene (PE)-based flashings',#8093,$,$); +#8103=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_30_72','Recycled plastics flashings',#8093,$,$); +#8104=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_30_83','Stainless steel flashings',#8093,$,$); +#8105=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_30_99','Zinc flashings',#8093,$,$); +#8106=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31','Floor and stair trims',#8010,$,$); +#8107=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_11','Carpet grippers',#8106,$,$); +#8108=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_12','Carpet gripper strips',#8106,$,$); +#8109=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_26','Flexible polyvinyl chloride (PVC) stair nosings',#8106,$,$); +#8110=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_27','Flexible stair coverings',#8106,$,$); +#8111=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_28','Floor construction joint trims',#8106,$,$); +#8112=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_29','Floor cover strips',#8106,$,$); +#8113=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_30','Floor dividing strips',#8106,$,$); +#8114=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_31','Floor edge trims',#8106,$,$); +#8115=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_32','Floor edging strips',#8106,$,$); +#8116=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_33','Floor threshold strips',#8106,$,$); +#8117=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_36','Hardwood floor threshold strips',#8106,$,$); +#8118=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_37','Hardwood stair trims',#8106,$,$); +#8119=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_50','Mat well frames',#8106,$,$); +#8120=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_58','One part floor transition strips',#8106,$,$); +#8121=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_66','Preformed strip joints to screeds',#8106,$,$); +#8122=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_70','Radiator pipe floor covers',#8106,$,$); +#8123=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_71','Raised access floor level-change trims',#8106,$,$); +#8124=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_72','Raised access floor vertical edging panels',#8106,$,$); +#8125=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_73','Render-grade resin coves',#8106,$,$); +#8126=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_74','Rigid stair nosings',#8106,$,$); +#8127=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_75','Rubber composite stair nosing inserts',#8106,$,$); +#8128=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_83','Stair rods',#8106,$,$); +#8129=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_84','Stair trims',#8106,$,$); +#8130=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_90','Two-part floor transition strips',#8106,$,$); +#8131=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_95','Wearing screed sawn-joint sealing strips',#8106,$,$); +#8132=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_96','Wood-based floor threshold strips',#8106,$,$); +#8133=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_31_97','Wood-based floor transition strips',#8106,$,$); +#8134=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33','Gaskets, weatherstrips and baffles',#8010,$,$); +#8135=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_12','Cellular rubber gaskets',#8134,$,$); +#8136=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_20','Curtain wall glazing and panel gaskets',#8134,$,$); +#8137=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_22','Door and window weatherstrips and seals',#8134,$,$); +#8138=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_23','Door threshold weatherstrips and seals',#8134,$,$); +#8139=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_24','Ethylene propylene diene monomer (EPDM) combined hydrophilic gaskets',#8134,$,$); +#8140=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_25','Ethylene propylene diene monomer (EPDM) gaskets',#8134,$,$); +#8141=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_26','Ethylene propylene diene monomer (EPDM) rubber section glazing trims',#8134,$,$); +#8142=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_28','Extruded polyvinyl chloride (PVC) glazing gaskets',#8134,$,$); +#8143=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_34','Glass-reinforced plastics (GRP) cladding neoprene gaskets',#8134,$,$); +#8144=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_39','Hydrophilic gaskets',#8134,$,$); +#8145=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_56','Neoprene baffles',#8134,$,$); +#8146=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_57','Non-cellular rubber gaskets',#8134,$,$); +#8147=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_64','Polypropylene baffles',#8134,$,$); +#8148=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_66','Pre-formed butyl strip glazing trims',#8134,$,$); +#8149=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_77','Single-sided glazing gaskets',#8134,$,$); +#8150=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_84','Stainless steel baffles',#8134,$,$); +#8151=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_86','Synthetic rubber glazing gaskets',#8134,$,$); +#8152=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_97','Weatherstripping',#8134,$,$); +#8153=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_33_99','Zipper gaskets',#8134,$,$); +#8154=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43','Interior wall and ceiling trims',#8010,$,$); +#8155=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_02','Aluminium skirtings',#8154,$,$); +#8156=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_03','Angle trims',#8154,$,$); +#8157=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_04','Arrises',#8154,$,$); +#8158=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_12','Ceiling perimeter trims',#8154,$,$); +#8159=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_13','Column guards',#8154,$,$); +#8160=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_14','Cork cove skirtings',#8154,$,$); +#8161=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_15','Corner guards',#8154,$,$); +#8162=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_16','Cover strips',#8154,$,$); +#8163=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_17','Coves',#8154,$,$); +#8164=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_21','Edge battens',#8154,$,$); +#8165=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_22','Edge trims',#8154,$,$); +#8166=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_29','Fibrous plaster mouldings',#8154,$,$); +#8167=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_30','Fire-insulating caps',#8154,$,$); +#8168=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_42','Intumescent protective castings',#8154,$,$); +#8169=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_47','Lighting cornices',#8154,$,$); +#8170=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_48','Medium density fibreboard (MDF) architraves',#8154,$,$); +#8171=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_49','Medium density fibreboard (MDF) backboards',#8154,$,$); +#8172=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_50','Medium density fibreboard (MDF) cover strips',#8154,$,$); +#8173=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_51','Medium density fibreboard (MDF) dado rails',#8154,$,$); +#8174=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_52','Medium density fibreboard (MDF) edge trims',#8154,$,$); +#8175=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_53','Medium density fibreboard (MDF) lining boards',#8154,$,$); +#8176=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_54','Medium density fibreboard (MDF) mouldings and trims',#8154,$,$); +#8177=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_55','Medium density fibreboard (MDF) mounting battens',#8154,$,$); +#8178=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_56','Medium density fibreboard (MDF) picture rails',#8154,$,$); +#8179=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_57','Medium density fibreboard (MDF) protection rails',#8154,$,$); +#8180=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_58','Medium density fibreboard (MDF) skirtings',#8154,$,$); +#8181=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_59','Metal skirtings',#8154,$,$); +#8182=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_60','Panel partition closer pieces',#8154,$,$); +#8183=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_61','Pilasters',#8154,$,$); +#8184=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_62','Plaster cornices',#8154,$,$); +#8185=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_63','Plastics skirtings',#8154,$,$); +#8186=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_64','Polyvinyl chloride (PVC) cove skirtings',#8154,$,$); +#8187=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_66','Preformed casings',#8154,$,$); +#8188=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_70','Radiator guards',#8154,$,$); +#8189=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_74','Rubber cove skirtings',#8154,$,$); +#8190=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_84','Solid cast plaster mouldings',#8154,$,$); +#8191=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_86','Wall protection panels',#8154,$,$); +#8192=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_87','Wood architraves',#8154,$,$); +#8193=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_88','Wood backboards',#8154,$,$); +#8194=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_89','Wood cover strips',#8154,$,$); +#8195=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_90','Wood dado rails',#8154,$,$); +#8196=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_91','Wood edge trims',#8154,$,$); +#8197=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_92','Wood fillets',#8154,$,$); +#8198=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_93','Wood lining boards',#8154,$,$); +#8199=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_94','Wood mouldings and trims',#8154,$,$); +#8200=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_95','Wood mounting battens',#8154,$,$); +#8201=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_96','Wood picture rails',#8154,$,$); +#8202=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_97','Wood protection rails',#8154,$,$); +#8203=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_43_98','Wood skirtings',#8154,$,$); +#8204=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_50','Masonry walling ancillary products',#8010,$,$); +#8205=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_50_03','Airbricks',#8204,$,$); +#8206=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_50_61','Perpend joint plastics cavity ventilators',#8204,$,$); +#8207=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_50_62','Perpend joint plastics weep holes',#8204,$,$); +#8208=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_50_63','Perpend joint metal weep holes',#8204,$,$); +#8209=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_50_64','Plastics cavity closers',#8204,$,$); +#8210=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_50_88','Tile creasings',#8204,$,$); +#8211=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_53','Movement joints',#8010,$,$); +#8212=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_53_11','Cast-in screed movement joints',#8211,$,$); +#8213=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_53_30','Fibre cement movement joints',#8211,$,$); +#8214=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_53_42','Insulated render system construction and movement joints',#8211,$,$); +#8215=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_53_50','Mastic asphalt (MA) movement joints',#8211,$,$); +#8216=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_53_52','Metal movement joint edging angles',#8211,$,$); +#8217=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_53_53','Metal section movement joints',#8211,$,$); +#8218=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_53_54','Minor flat roofing movement joints',#8211,$,$); +#8219=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_53_72','Resin flooring strip movement joints',#8211,$,$); +#8220=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_53_85','Sprayed monolithic coating movement joints',#8211,$,$); +#8221=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_53_86','Strip movement joints',#8211,$,$); +#8222=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_53_88','Timber flooring movement joints',#8211,$,$); +#8223=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_53_93','Unplasticized polyvinyl chloride (PVC-U) external render and plaster movement joints',#8211,$,$); +#8224=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_60','Paving studs and inserts',#8010,$,$); +#8225=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_60_22','Demarcation inserts',#8224,$,$); +#8226=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_60_41','Illuminated road studs',#8224,$,$); +#8227=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_60_57','Non-reflecting road studs',#8224,$,$); +#8228=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_60_62','Pedestrian delineation road studs',#8224,$,$); +#8229=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_60_71','Retroreflecting road studs',#8224,$,$); +#8230=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_60_77','Skateboard deterrent studs',#8224,$,$); +#8231=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_60_78','Slip-resistant cast inserts',#8224,$,$); +#8232=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_60_79','Slip-resistant rebate inserts',#8224,$,$); +#8233=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_60_87','Tactile paving studs',#8224,$,$); +#8234=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87','Tapes, strips and profile fillers',#8010,$,$); +#8235=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_01','Acrylic adhesive fixing tapes',#8234,$,$); +#8236=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_02','Acrylic adhesive sealant tapes',#8234,$,$); +#8237=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_03','Aluminium conductor tapes',#8234,$,$); +#8238=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_04','Aluminium foil tapes',#8234,$,$); +#8239=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_07','Butyl rubber adhesive tapes',#8234,$,$); +#8240=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_08','Butyl rubber preformed strips',#8234,$,$); +#8241=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_09','Butyl rubber sealant tapes',#8234,$,$); +#8242=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_10','Butyl rubber fleece tapes',#8234,$,$); +#8243=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_15','Copper conductor tapes',#8234,$,$); +#8244=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_23','Double-sided tape damp proof course joint sealers',#8234,$,$); +#8245=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_25','Ethylene propylene diene monomer (EPDM)-coated expanded polyethylene (PE) foam profile fillers',#8234,$,$); +#8246=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_26','Expanded polyethylene (PE) foam profile fillers',#8234,$,$); +#8247=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_27','Expanded polyethylene (PE) foam strips',#8234,$,$); +#8248=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_28','Expanded polystyrene (EPS) foam strips',#8234,$,$); +#8249=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_30','Fire-resistant glazing tapes',#8234,$,$); +#8250=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_31','Flash tapes',#8234,$,$); +#8251=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_34','Glass fibre mesh repair tapes',#8234,$,$); +#8252=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_37','Heat-bonded carpet tapes',#8234,$,$); +#8253=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_41','Intumescent tapes',#8234,$,$); +#8254=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_42','Isolating tapes',#8234,$,$); +#8255=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_52','Metal strip reinforced paper tapes',#8234,$,$); +#8256=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_53','Mineral fibre joint fillers',#8234,$,$); +#8257=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_54','Mineral fibre profile fillers',#8234,$,$); +#8258=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_56','Non-impregnated foam glazing tapes',#8234,$,$); +#8259=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_60','Paper jointing tapes',#8234,$,$); +#8260=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_64','Polyethylene (PE) debonding tapes',#8234,$,$); +#8261=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_66','Polytetrafluoroethylene (PTFE) tapes',#8234,$,$); +#8262=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_67','Pre-formed butyl shim glazing tapes',#8234,$,$); +#8263=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_71','Resin impregnated pre-compressed foam sealing strips',#8234,$,$); +#8264=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_72','Retroreflective self-adhesive tapes',#8234,$,$); +#8265=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_77','Self-adhesive bitumen tapes',#8234,$,$); +#8266=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_78','Self-adhesive sports marking tapes',#8234,$,$); +#8267=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_84','Structural glazing tapes',#8234,$,$); +#8268=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_85','Synthetic closed cell foam rubber profile fillers',#8234,$,$); +#8269=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_86','Synthetic rubber strips',#8234,$,$); +#8270=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_97','Water polo field marking lines',#8234,$,$); +#8271=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_87_98','Woven glass fibre fabric strips',#8234,$,$); +#8272=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93','Unit roofing fittings',#8010,$,$); +#8273=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_07','Bitumen membrane shingle cappings',#8272,$,$); +#8274=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_12','Clay tile hip fittings',#8272,$,$); +#8275=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_13','Clay tile ridge fittings',#8272,$,$); +#8276=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_14','Clay tile roof slope ventilation fittings',#8272,$,$); +#8277=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_15','Clay tile valley fittings',#8272,$,$); +#8278=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_16','Clay tile verge fittings',#8272,$,$); +#8279=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_19','Concrete tile hip fittings',#8272,$,$); +#8280=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_21','Concrete tile ridge fittings',#8272,$,$); +#8281=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_22','Concrete tile roof slope ventilation fittings',#8272,$,$); +#8282=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_23','Concrete tile valley fittings',#8272,$,$); +#8283=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_24','Concrete tile verge fittings',#8272,$,$); +#8284=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_26','Dentil slips',#8272,$,$); +#8285=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_27','Dry fixing abutments',#8272,$,$); +#8286=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_28','Dry fixing hips',#8272,$,$); +#8287=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_29','Dry fixing ridges',#8272,$,$); +#8288=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_30','Dry fixing verges',#8272,$,$); +#8289=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_32','Fibre-cement slate hip fittings',#8272,$,$); +#8290=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_33','Fibre-cement slate ridge fittings',#8272,$,$); +#8291=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_34','Fibre-cement slate roof slope ventilation fittings',#8272,$,$); +#8292=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_35','Fibre-cement slate verge fittings',#8272,$,$); +#8293=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_51','Metal tile hip fittings',#8272,$,$); +#8294=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_52','Metal tile ridge fittings',#8272,$,$); +#8295=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_53','Metal tile verge fittings',#8272,$,$); +#8296=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_72','Reconstituted slate roof slope ventilation fittings',#8272,$,$); +#8297=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_96','Wood shake fittings',#8272,$,$); +#8298=IFCCLASSIFICATIONREFERENCE($,'Pr_35_90_93_97','Wood shingle fittings',#8272,$,$); +#8299=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93','Unit covering and finish products',#7593,$,$); +#8300=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_13','Ceiling infill units',#8299,$,$); +#8301=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_13_13','Cement bonded wood wool infill units',#8300,$,$); +#8302=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_13_30','Fibre reinforced gypsum infill units',#8300,$,$); +#8303=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_13_51','Metal infill units',#8300,$,$); +#8304=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_13_53','Mineral fibre infill units',#8300,$,$); +#8305=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_13_58','Open cell infill units',#8300,$,$); +#8306=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_13_61','Panel diffuser infill units',#8300,$,$); +#8307=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_13_65','Profiled metal acoustic panels',#8300,$,$); +#8308=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_13_71','Resin bonded mineral wool infill units',#8300,$,$); +#8309=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_13_73','Rigid urethane foam infill units',#8300,$,$); +#8310=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_13_80','Sound attenuator infill units',#8300,$,$); +#8311=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_13_94','Veneered wood composite infill units',#8300,$,$); +#8312=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96','Wall and floor tile units',#8299,$,$); +#8313=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_10','Cast stone slabs',#8312,$,$); +#8314=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_11','Cast stone tiles',#8312,$,$); +#8315=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_12','Ceramic tile angle beads',#8312,$,$); +#8316=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_13','Ceramic tile borders',#8312,$,$); +#8317=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_14','Ceramic tile cove skirtings',#8312,$,$); +#8318=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_15','Ceramic tile floor channels',#8312,$,$); +#8319=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_16','Ceramic tile round edges',#8312,$,$); +#8320=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_17','Ceramic tile sit-on skirtings',#8312,$,$); +#8321=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_18','Ceramic tile step treads',#8312,$,$); +#8322=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_19','Ceramic tiles',#8312,$,$); +#8323=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_21','Concrete tiles',#8312,$,$); +#8324=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_34','Graphic-printed porcelain tiles',#8312,$,$); +#8325=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_53','Mosaic tiles',#8312,$,$); +#8326=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_56','Natural stone wall and floor slabs',#8312,$,$); +#8327=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_57','Natural stone tiles',#8312,$,$); +#8328=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_63','Porcelain tiles',#8312,$,$); +#8329=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_66','Quarry tile borders',#8312,$,$); +#8330=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_67','Quarry tile cove skirtings',#8312,$,$); +#8331=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_68','Quarry tile floor channels',#8312,$,$); +#8332=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_70','Quarry tile sit-on skirtings',#8312,$,$); +#8333=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_71','Quarry tile step treads',#8312,$,$); +#8334=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_72','Quarry tiles',#8312,$,$); +#8335=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_85','Stone slabs',#8312,$,$); +#8336=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_86','Stone tiles',#8312,$,$); +#8337=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_87','Tile matting',#8312,$,$); +#8338=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_88','Terrazzo precast units',#8312,$,$); +#8339=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_89','Terrazzo tile skirtings',#8312,$,$); +#8340=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_90','Terrazzo tiles',#8312,$,$); +#8341=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_96_92','Tile spacers',#8312,$,$); +#8342=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_97','Wood block units',#8299,$,$); +#8343=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_97_15','Composition blocks',#8342,$,$); +#8344=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_97_52','Mosaic panels',#8342,$,$); +#8345=IFCCLASSIFICATIONREFERENCE($,'Pr_35_93_97_96','Wood blocks',#8342,$,$); +#8346=IFCCLASSIFICATIONREFERENCE($,'Pr_40','Signage, sanitary fittings and fittings, furnishing and equipment (FF&E) products',#4923,$,$); +#8347=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10','Signage products',#8346,$,$); +#8348=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_27','Electrical services signs',#8347,$,$); +#8349=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_27_24','Electrical diagrams',#8348,$,$); +#8350=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_27_27','Electrical shock treatment signs',#8348,$,$); +#8351=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_27_28','Externally illuminated emergency exit signs',#8348,$,$); +#8352=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_27_43','Induction loop system signs',#8348,$,$); +#8353=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_27_62','Photoluminescent emergency signs',#8348,$,$); +#8354=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_27_63','Photoluminescent low mounted way-guidance lighting',#8348,$,$); +#8355=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_27_86','Surveillance system signs',#8348,$,$); +#8356=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_27_88','Telecommunications equipment and outlets labels',#8348,$,$); +#8357=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_27_91','Underground cable marker tapes',#8348,$,$); +#8358=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57','Notices, identification and labels',#8347,$,$); +#8359=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_10','Burnt clay warning marker tiles',#8358,$,$); +#8360=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_12','Cable marker tags',#8358,$,$); +#8361=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_15','Concrete warning marker tiles',#8358,$,$); +#8362=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_21','Door number labels',#8358,$,$); +#8363=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_24','Electrical identification labels',#8358,$,$); +#8364=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_26','Engraved mechanical plant and equipment identification labels',#8358,$,$); +#8365=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_27','Engraved valve charts and schematics',#8358,$,$); +#8366=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_28','Engraved valve identification labels',#8358,$,$); +#8367=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_29','Equipment labels and warning notices',#8358,$,$); +#8368=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_32','Fire hydrant indicator plates',#8358,$,$); +#8369=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_36','Heat shrink sleeves',#8358,$,$); +#8370=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_39','Images and logos',#8358,$,$); +#8371=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_40','Inclined stair lift notices',#8358,$,$); +#8372=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_50','Marker posts',#8358,$,$); +#8373=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_52','Metal ductwork labels',#8358,$,$); +#8374=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_56','Nail identification washers',#8358,$,$); +#8375=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_60','Paper valve charts and schematics',#8358,$,$); +#8376=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_63','Plants delivery labels',#8358,$,$); +#8377=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_64','Plants permanent labels',#8358,$,$); +#8378=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_65','Plastics ductwork labels',#8358,$,$); +#8379=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_66','Plastics warning marker boards',#8358,$,$); +#8380=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_67','Platform lift notices',#8358,$,$); +#8381=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_71','Room name labels',#8358,$,$); +#8382=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_72','Room number labels',#8358,$,$); +#8383=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_76','Screen-printed mechanical plant and equipment identification labels',#8358,$,$); +#8384=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_77','Screen-printed valve identification labels',#8358,$,$); +#8385=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_78','Self-adhesive colour pipe bands',#8358,$,$); +#8386=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_79','Self-adhesive plastics ductwork labels and transfers',#8358,$,$); +#8387=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_96','Warning marker tapes',#8358,$,$); +#8388=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_97','Warning marker tiles',#8358,$,$); +#8389=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_98','Water firefighting system identification and labels',#8358,$,$); +#8390=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_57_99','Window number labels',#8358,$,$); +#8391=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77','Signs and markers',#8347,$,$); +#8392=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_02','\X2\2018\X0\A\X2\2019\X0\ boards',#8391,$,$); +#8393=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_04','Alpha numeric characters',#8391,$,$); +#8394=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_05','Applied glazing details',#8391,$,$); +#8395=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_06','Banner signs',#8391,$,$); +#8396=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_07','Beach safety flags',#8391,$,$); +#8397=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_08','Braille signs',#8391,$,$); +#8398=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_11','Cabinet signs',#8391,$,$); +#8399=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_20','Datum plates and markers',#8391,$,$); +#8400=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_22','Designation signs',#8391,$,$); +#8401=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_24','Directory signs',#8391,$,$); +#8402=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_27','Evacuation signs',#8391,$,$); +#8403=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_29','Fencing safety reflectors',#8391,$,$); +#8404=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_30','Finger signs',#8391,$,$); +#8405=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_31','Fire equipment signs',#8391,$,$); +#8406=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_32','Fire escape route signs',#8391,$,$); +#8407=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_36','Hazard delineators',#8391,$,$); +#8408=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_37','Highway marker posts',#8391,$,$); +#8409=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_38','Hoarding signs',#8391,$,$); +#8410=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_41','Illuminated signs',#8391,$,$); +#8411=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_42','Individual letter signs',#8391,$,$); +#8412=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_46','Ladder signs',#8391,$,$); +#8413=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_50','Mandatory action signs',#8391,$,$); +#8414=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_52','Monolith signs',#8391,$,$); +#8415=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_53','Moving signs',#8391,$,$); +#8416=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_56','Nameplates',#8391,$,$); +#8417=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_61','Phosphorescent way guidance tapes',#8391,$,$); +#8418=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_63','Plaques',#8391,$,$); +#8419=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_64','Platform lift signs',#8391,$,$); +#8420=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_66','Prohibition signs',#8391,$,$); +#8421=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_69','Public access stair lift signs',#8391,$,$); +#8422=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_70','Railway signs',#8391,$,$); +#8423=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_72','Road traffic signs',#8391,$,$); +#8424=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_74','Safety equipment signs',#8391,$,$); +#8425=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_75','Safe condition signs',#8391,$,$); +#8426=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_76','Safety signs',#8391,$,$); +#8427=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_77','Signboards',#8391,$,$); +#8428=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_79','Sliding cover signs',#8391,$,$); +#8429=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_82','Stair lift signs',#8391,$,$); +#8430=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_84','Street sign plates',#8391,$,$); +#8431=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_85','Street signs',#8391,$,$); +#8432=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_86','Survey markers',#8391,$,$); +#8433=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_88','Toposcopes',#8391,$,$); +#8434=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_89','Traffic cones',#8391,$,$); +#8435=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_90','Traffic cylinders',#8391,$,$); +#8436=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_92','Variable message signs',#8391,$,$); +#8437=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_94','Verge markers',#8391,$,$); +#8438=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_96','Warning markers',#8391,$,$); +#8439=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_97','Warning signs',#8391,$,$); +#8440=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_98','Waymarker discs',#8391,$,$); +#8441=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_77_99','Waymarker posts',#8391,$,$); +#8442=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_90','Water and navigation aid signs',#8347,$,$); +#8443=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_90_07','Beacons',#8442,$,$); +#8444=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_90_10','Buoys',#8442,$,$); +#8445=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_90_31','Fog signals',#8442,$,$); +#8446=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_90_50','Marine traffic signals',#8442,$,$); +#8447=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_90_56','Navigation signs',#8442,$,$); +#8448=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_96','Wind direction indicator products',#8347,$,$); +#8449=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_96_96','Weathervanes',#8448,$,$); +#8450=IFCCLASSIFICATIONREFERENCE($,'Pr_40_10_96_98','Windsocks',#8448,$,$); +#8451=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20','Sanitary fittings and accessories',#8346,$,$); +#8452=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_06','Bathing fittings',#8451,$,$); +#8453=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_06_02','Accessible baths',#8452,$,$); +#8454=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_06_08','Baths',#8452,$,$); +#8455=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_06_11','Bidets',#8452,$,$); +#8456=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_06_36','Health care general baths',#8452,$,$); +#8457=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_06_38','Hospital pattern bidets',#8452,$,$); +#8458=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_06_79','Shower enclosures',#8452,$,$); +#8459=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_06_83','Shower seats',#8452,$,$); +#8460=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_06_84','Shower trays',#8452,$,$); +#8461=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_06_99','Whirlpool baths',#8452,$,$); +#8462=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_27','Emergency shower products',#8451,$,$); +#8463=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_27_15','Combined emergency shower and eye wash stations',#8462,$,$); +#8464=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_27_28','Eye wash fountains',#8462,$,$); +#8465=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_27_75','Safety showers',#8462,$,$); +#8466=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_60','Packaged sanitary fittings',#8451,$,$); +#8467=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_60_02','Accessible WC equipment packages',#8466,$,$); +#8468=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_60_75','Sauna room packages',#8466,$,$); +#8469=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_60_78','Shower enclosure packages',#8466,$,$); +#8470=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_60_85','Steam cabinet packages',#8466,$,$); +#8471=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_60_86','Steam room packages',#8466,$,$); +#8472=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_60_96','Wet room floor formers',#8466,$,$); +#8473=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76','Sanitary accessories',#8451,$,$); +#8474=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_01','Adult changing units',#8473,$,$); +#8475=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_02','Air fresheners',#8473,$,$); +#8476=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_06','Baby changing units',#8473,$,$); +#8477=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_07','Bath panels',#8473,$,$); +#8478=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_82','Soap dishes',#8473,$,$); +#8479=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_83','Splashbacks',#8473,$,$); +#8480=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_84','Support rails',#8473,$,$); +#8481=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_86','Toilet brush holders',#8473,$,$); +#8482=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_88','Toilet roll holders',#8473,$,$); +#8483=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_89','Toothbrush holders',#8473,$,$); +#8484=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_90','Towel rails',#8473,$,$); +#8485=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_91','Towel rings',#8473,$,$); +#8486=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_92','Tumbler holders',#8473,$,$); +#8487=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_94','Vanity units',#8473,$,$); +#8488=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_76_98','WC pan backrests',#8473,$,$); +#8489=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87','Taps and water supply outlet fittings',#8451,$,$); +#8490=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_07','Bath manual water supply sets',#8489,$,$); +#8491=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_08','Bath spouts',#8489,$,$); +#8492=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_09','Bath taps',#8489,$,$); +#8493=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_10','Bath thermostatic water supply sets',#8489,$,$); +#8494=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_11','Bidet taps',#8489,$,$); +#8495=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_31','Foot-operated valves',#8489,$,$); +#8496=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_33','Garden taps',#8489,$,$); +#8497=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_35','Grip valves',#8489,$,$); +#8498=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_43','Key-operated valves',#8489,$,$); +#8499=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_49','Knee-operated valves',#8489,$,$); +#8500=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_75','Shower fittings package',#8489,$,$); +#8501=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_76','Shower heads',#8489,$,$); +#8502=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_77','Shower head holders',#8489,$,$); +#8503=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_78','Shower manual water supply sets',#8489,$,$); +#8504=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_79','Shower self-closing (emergency) valves',#8489,$,$); +#8505=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_80','Shower thermostatic valves',#8489,$,$); +#8506=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_81','Shower thermostatic water supply sets',#8489,$,$); +#8507=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_82','Sink manual water supply sets',#8489,$,$); +#8508=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_83','Sink spouts',#8489,$,$); +#8509=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_84','Sink taps',#8489,$,$); +#8510=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_85','Sink thermostatic water supply sets',#8489,$,$); +#8511=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_89','Toilet showers',#8489,$,$); +#8512=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_96','Washbasin manual water supply sets',#8489,$,$); +#8513=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_97','Washbasin spouts',#8489,$,$); +#8514=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_98','Washbasin taps',#8489,$,$); +#8515=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_87_99','Washbasin thermostatic water supply sets',#8489,$,$); +#8516=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93','Urinal and WC fittings',#8451,$,$); +#8517=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_30','Floor standing urinals',#8516,$,$); +#8518=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_36','Health care macerators',#8516,$,$); +#8519=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_37','Hospital pattern disposal units',#8516,$,$); +#8520=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_38','Hospital pattern urinals',#8516,$,$); +#8521=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_39','Hospital pattern WC pans and cisterns',#8516,$,$); +#8522=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_62','Pre-plumbed installation frames',#8516,$,$); +#8523=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_74','Urinal dividers',#8516,$,$); +#8524=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_77','Slab urinals',#8516,$,$); +#8525=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_78','Urinal cisterns',#8516,$,$); +#8526=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_79','Urinal flushing valves',#8516,$,$); +#8527=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_80','Urinal flush pipes',#8516,$,$); +#8528=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_82','Wall-hung urinals',#8516,$,$); +#8529=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_84','Waterless urinals',#8516,$,$); +#8530=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_85','Waterless toilets',#8516,$,$); +#8531=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_86','WC and washbasin combined units',#8516,$,$); +#8532=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_87','WC cistern fittings',#8516,$,$); +#8533=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_89','WC cisterns',#8516,$,$); +#8534=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_90','WC cistern flush pipes',#8516,$,$); +#8535=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_91','WC flushing valves',#8516,$,$); +#8536=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_92','WC large capacity replacement cisterns',#8516,$,$); +#8537=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_93','WC pan connectors',#8516,$,$); +#8538=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_94','WC pans',#8516,$,$); +#8539=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_95','WC seats and covers',#8516,$,$); +#8540=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_96','WC squatting pans',#8516,$,$); +#8541=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_97','WC suites',#8516,$,$); +#8542=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_93_99','WC, wash and dry combined units',#8516,$,$); +#8543=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96','Wash basins, sinks and troughs',#8451,$,$); +#8544=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_15','Ceramic sinks',#8543,$,$); +#8545=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_17','Commercial kitchen rinsing sinks',#8543,$,$); +#8546=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_18','Counter top wash basins',#8543,$,$); +#8547=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_34','Health care clinical sinks with drainers',#8543,$,$); +#8548=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_35','Health care clinical wash basins',#8543,$,$); +#8549=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_36','Health care domestic service sinks',#8543,$,$); +#8550=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_37','Health care general wash basins',#8543,$,$); +#8551=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_38','Health care hand rinse basins',#8543,$,$); +#8552=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_39','Hospital pattern plaster sinks',#8543,$,$); +#8553=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_40','Hospital pattern scrub-up troughs',#8543,$,$); +#8554=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_42','Integral wash basins and vanity tops',#8543,$,$); +#8555=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_44','Janitorial sinks',#8543,$,$); +#8556=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_45','Kitchen sinks',#8543,$,$); +#8557=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_46','Laundry troughs',#8543,$,$); +#8558=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_47','Laundry troughs and cabinets',#8543,$,$); +#8559=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_63','Pedestal wash basins',#8543,$,$); +#8560=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_70','Recessed wash basins',#8543,$,$); +#8561=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_81','Sinks',#8543,$,$); +#8562=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_92','Undermounted wash basins',#8543,$,$); +#8563=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_95','Wall-hung hand rinse basins',#8543,$,$); +#8564=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_96','Wall-hung wash basins',#8543,$,$); +#8565=IFCCLASSIFICATIONREFERENCE($,'Pr_40_20_96_99','Wash troughs',#8543,$,$); +#8566=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30','Fittings',#8346,$,$); +#8567=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04','Animal housing',#8566,$,$); +#8568=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04_02','Animal feeding stations',#8567,$,$); +#8569=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04_06','Bat boxes',#8567,$,$); +#8570=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04_07','Bird baths',#8567,$,$); +#8571=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04_08','Bird boxes',#8567,$,$); +#8572=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04_09','Bird roosts',#8567,$,$); +#8573=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04_15','Columbaria',#8567,$,$); +#8574=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04_24','Dog kennels',#8567,$,$); +#8575=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04_25','Dovecotes',#8567,$,$); +#8576=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04_41','Insect houses',#8567,$,$); +#8577=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04_50','Mammal houses',#8567,$,$); +#8578=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04_56','Nesting baskets',#8567,$,$); +#8579=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04_57','Nest poles and platforms',#8567,$,$); +#8580=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_04_70','Raptor poles',#8567,$,$); +#8581=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20','Curtains and screens',#8566,$,$); +#8582=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_02','Acoustic curtains',#8581,$,$); +#8583=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_03','Acoustic screens',#8581,$,$); +#8584=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_13','Choir screens',#8581,$,$); +#8585=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_38','Hospital bed screens',#8581,$,$); +#8586=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_58','Organ screens',#8581,$,$); +#8587=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_59','Ornamental screens',#8581,$,$); +#8588=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_63','Privacy curtain supports',#8581,$,$); +#8589=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_64','Privacy curtains',#8581,$,$); +#8590=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_65','Privacy screens',#8581,$,$); +#8591=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_67','Polyvinyl chloride (PVC) strip curtains',#8581,$,$); +#8592=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_70','Recessed curtain pelmets',#8581,$,$); +#8593=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_71','Relaxation screens',#8581,$,$); +#8594=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_77','Shower curtain rails',#8581,$,$); +#8595=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_78','Shower curtains',#8581,$,$); +#8596=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_83','Stage curtain supports',#8581,$,$); +#8597=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_84','Stage curtains',#8581,$,$); +#8598=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_86','Surface mounted curtain pelmets',#8581,$,$); +#8599=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_96','Window curtain supports',#8581,$,$); +#8600=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_20_97','Window curtains',#8581,$,$); +#8601=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_21','Cycle stands and lockers',#8566,$,$); +#8602=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_21_02','Aluminium cycle lockers',#8601,$,$); +#8603=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_21_11','Carbon steel cycle lockers',#8601,$,$); +#8604=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_21_12','Carbon steel cycle stands',#8601,$,$); +#8605=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_21_13','Ceiling-mounted cycle supports',#8601,$,$); +#8606=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_21_35','Ground-mounted cycle stands',#8601,$,$); +#8607=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_21_36','Hardwood cycle stands',#8601,$,$); +#8608=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_21_65','Plastics cycle lockers',#8601,$,$); +#8609=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_21_83','Stainless steel cycle lockers',#8601,$,$); +#8610=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_21_84','Stainless steel cycle stands',#8601,$,$); +#8611=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_21_96','Wall-mounted cycle stands',#8601,$,$); +#8612=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22','Deterrents and traps',#8566,$,$); +#8613=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_02','Animal deterrents',#8612,$,$); +#8614=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_05','Bait stations',#8612,$,$); +#8615=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_06','Bird deterrent spikes',#8612,$,$); +#8616=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_11','Cage traps',#8612,$,$); +#8617=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_14','Coiled wire bird deterrents',#8612,$,$); +#8618=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_22','Decoy predators',#8612,$,$); +#8619=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_26','Electric pulse tactile/track bird deterrents',#8612,$,$); +#8620=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_30','Flight diverters',#8612,$,$); +#8621=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_31','Frond bird deterrents',#8612,$,$); +#8622=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_34','Guard barriers',#8612,$,$); +#8623=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_38','Humane traps',#8612,$,$); +#8624=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_40','Inclined surface bird deterrents',#8612,$,$); +#8625=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_46','Laser bird repellers',#8612,$,$); +#8626=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_48','Low tension wire bird (gull) deterrents',#8612,$,$); +#8627=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_56','Non-toxic rat and mouse baits',#8612,$,$); +#8628=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_60','Pheromone traps',#8612,$,$); +#8629=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_64','Powered traps',#8612,$,$); +#8630=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_66','Powered ultraviolet light traps',#8612,$,$); +#8631=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_76','Scare eyes',#8612,$,$); +#8632=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_80','Sonic deterrents',#8612,$,$); +#8633=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_82','Spring traps',#8612,$,$); +#8634=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_84','Sprung tension wire bird deterrents',#8612,$,$); +#8635=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_87','Tactile gels and liquids deterrents',#8612,$,$); +#8636=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_89','Taste and scent bird deterrents',#8612,$,$); +#8637=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_92','Ultrasonic rodent repellers',#8612,$,$); +#8638=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_95','Vision disturbance bird deterrents',#8612,$,$); +#8639=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_22_96','Visual threat bird deterrents',#8612,$,$); +#8640=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25','Display and presentation fittings',#8566,$,$); +#8641=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_03','Audible signs',#8640,$,$); +#8642=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_04','Audio visual furniture',#8640,$,$); +#8643=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_13','Chalkboards',#8640,$,$); +#8644=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_17','Computer generated signs',#8640,$,$); +#8645=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_21','Demountable podiums and staging',#8640,$,$); +#8646=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_22','Desktop lecterns',#8640,$,$); +#8647=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_23','Display screens',#8640,$,$); +#8648=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_25','Dot matrix displays',#8640,$,$); +#8649=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_30','Freestanding screens',#8640,$,$); +#8650=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_42','Interactive whiteboards',#8640,$,$); +#8651=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_46','Lecterns',#8640,$,$); +#8652=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_47','Light emitting diode (LED) panels',#8640,$,$); +#8653=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_48','Liquid crystal display (LCD) panels',#8640,$,$); +#8654=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_50','Magnetic boards',#8640,$,$); +#8655=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_55','Multimedia screens',#8640,$,$); +#8656=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_58','Notice boards',#8640,$,$); +#8657=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_64','Pinboards',#8640,$,$); +#8658=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_65','Plasma display screens',#8640,$,$); +#8659=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_67','Projection screens',#8640,$,$); +#8660=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_71','Retail display fittings',#8640,$,$); +#8661=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_88','Teaching walls',#8640,$,$); +#8662=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_25_96','Whiteboards',#8640,$,$); +#8663=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_26','Drying lines',#8566,$,$); +#8664=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_26_12','Ceiling mounted clothes-drying lines',#8663,$,$); +#8665=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_26_30','Folding wall mounted clothes-drying lines',#8663,$,$); +#8666=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_26_32','Free standing clothes-drying lines',#8663,$,$); +#8667=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_26_55','Multiple line retractable clothes-drying lines',#8663,$,$); +#8668=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_26_63','Photographic film-drying lines',#8663,$,$); +#8669=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_26_65','Portable clothes-drying lines',#8663,$,$); +#8670=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_26_72','Rotary clothes-drying lines',#8663,$,$); +#8671=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_26_79','Single line retractable clothes-drying lines',#8663,$,$); +#8672=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29','Fitted chairs, seats and benches',#8566,$,$); +#8673=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_05','Auditorium seating',#8672,$,$); +#8674=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_12','Choir seating',#8672,$,$); +#8675=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_13','Choir stalls',#8672,$,$); +#8676=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_22','Demountable seats',#8672,$,$); +#8677=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_29','Fixed seats',#8672,$,$); +#8678=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_31','Fixed observation poolside chairs',#8672,$,$); +#8679=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_46','Leaning rails',#8672,$,$); +#8680=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_61','Pedicure chairs',#8672,$,$); +#8681=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_72','Retractable seats',#8672,$,$); +#8682=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_79','Sitting rails',#8672,$,$); +#8683=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_83','Spa foot ritual benches',#8672,$,$); +#8684=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_84','Street and site benches',#8672,$,$); +#8685=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_85','Street and site seats',#8672,$,$); +#8686=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_88','Thrones',#8672,$,$); +#8687=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_96','Wall-fixed lift-up seats',#8672,$,$); +#8688=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_97','Wall-mounted gallery benches',#8672,$,$); +#8689=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_29_98','Window seats',#8672,$,$); +#8690=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30','Fitted desks, tables and worktops',#8566,$,$); +#8691=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_18','Counter tops',#8690,$,$); +#8692=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_22','Dishwasher inlet tables',#8690,$,$); +#8693=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_23','Dishwasher outlet tables',#8690,$,$); +#8694=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_32','Food preparation worktops',#8690,$,$); +#8695=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_42','Industrial work benches',#8690,$,$); +#8696=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_45','Kitchen splashbacks',#8690,$,$); +#8697=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_47','Laboratory work benches',#8690,$,$); +#8698=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_48','Laboratory worktops',#8690,$,$); +#8699=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_62','Picnic tables',#8690,$,$); +#8700=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_71','Reception desks',#8690,$,$); +#8701=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_78','School art, design and technology work benches',#8690,$,$); +#8702=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_79','Servery counters',#8690,$,$); +#8703=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_80','Sink tables',#8690,$,$); +#8704=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_86','Street and site tables',#8690,$,$); +#8705=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_30_96','Worktops',#8690,$,$); +#8706=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_31','Flagpoles',#8566,$,$); +#8707=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_31_29','Fan-assisted ground-mounted flagpoles',#8706,$,$); +#8708=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_31_33','Ground-mounted banner poles',#8706,$,$); +#8709=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_31_34','Ground-mounted flagpoles',#8706,$,$); +#8710=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_31_35','Ground-mounted sleeved flagpoles',#8706,$,$); +#8711=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_31_53','Mobile telescopic flagpoles',#8706,$,$); +#8712=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_31_70','Rigged and guyed flagpoles',#8706,$,$); +#8713=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_31_71','Rigged un-guyed flagpoles',#8706,$,$); +#8714=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_31_96','Wall-mounted flagpoles',#8706,$,$); +#8715=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_50','Mail fittings',#8566,$,$); +#8716=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_50_46','Letter boxes',#8715,$,$); +#8717=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_50_47','Letter cages',#8715,$,$); +#8718=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_50_48','Letter plate internal flaps and seals',#8715,$,$); +#8719=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_50_49','Letter plates',#8715,$,$); +#8720=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_50_62','Pigeonholes',#8715,$,$); +#8721=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_50_65','Post boxes',#8715,$,$); +#8722=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_55','Musical instruments',#8566,$,$); +#8723=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_55_06','Bell frames',#8722,$,$); +#8724=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_55_07','Bell headstocks',#8722,$,$); +#8725=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_55_08','Bell wheels',#8722,$,$); +#8726=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_55_10','Bracket bells',#8722,$,$); +#8727=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_55_77','Ship\X2\2019\X0\s bells',#8722,$,$); +#8728=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_55_89','Tower bells',#8722,$,$); +#8729=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_55_90','Tubular bells',#8722,$,$); +#8730=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_55_91','Turret bells',#8722,$,$); +#8731=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61','Play equipment',#8566,$,$); +#8732=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_15','Climbing frames',#8731,$,$); +#8733=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_18','Combined play structures',#8731,$,$); +#8734=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_40','Imaginative play structures',#8731,$,$); +#8735=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_42','Infants'' swings',#8731,$,$); +#8736=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_52','Modular play climbers',#8731,$,$); +#8737=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_61','Play panels',#8731,$,$); +#8738=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_62','Play pools',#8731,$,$); +#8739=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_63','Play roundabouts',#8731,$,$); +#8740=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_64','Play runways',#8731,$,$); +#8741=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_65','Play sandpits',#8731,$,$); +#8742=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_66','Play slides',#8731,$,$); +#8743=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_67','Play swings',#8731,$,$); +#8744=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_77','See-saws',#8731,$,$); +#8745=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_78','Sensory play structures',#8731,$,$); +#8746=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_79','Sit-on rockers',#8731,$,$); +#8747=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_82','Spinning poles',#8731,$,$); +#8748=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_88','Traditional rockers',#8731,$,$); +#8749=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_95','Water play equipment',#8731,$,$); +#8750=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_96','Water play fountains',#8731,$,$); +#8751=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_97','Water play structures',#8731,$,$); +#8752=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_61_98','Wobble boards',#8731,$,$); +#8753=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_65','Point of sale fittings',#8566,$,$); +#8754=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_65_11','Cash registers',#8753,$,$); +#8755=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_65_12','Cash transfer units',#8753,$,$); +#8756=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_65_13','Cashier drawers',#8753,$,$); +#8757=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_65_60','Paystations and troughs',#8753,$,$); +#8758=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_65_65','Point of sale units',#8753,$,$); +#8759=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_65_88','Tills',#8753,$,$); +#8760=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_66','Poster display units',#8566,$,$); +#8761=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_66_22','Digital poster display units',#8760,$,$); +#8762=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_66_73','Rolling poster display units',#8760,$,$); +#8763=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_66_74','Rotating poster display units',#8760,$,$); +#8764=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_66_84','Static poster display units',#8760,$,$); +#8765=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_71','Religious fittings',#8566,$,$); +#8766=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_71_01','Abats-voix',#8765,$,$); +#8767=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_71_03','Ambons',#8765,$,$); +#8768=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_71_06','Baldachins',#8765,$,$); +#8769=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_71_07','Bimahs',#8765,$,$); +#8770=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_71_31','Fonts',#8765,$,$); +#8771=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_71_36','Hassocks',#8765,$,$); +#8772=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_71_51','Minbars',#8765,$,$); +#8773=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_71_56','Nave lecterns',#8765,$,$); +#8774=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_71_68','Pulpits',#8765,$,$); +#8775=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75','Safes and security cabinets',#8566,$,$); +#8776=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_11','Cash safes',#8775,$,$); +#8777=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_16','Computer safes',#8775,$,$); +#8778=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_20','Cupboard safes',#8775,$,$); +#8779=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_21','Data protection safes',#8775,$,$); +#8780=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_22','Deposit safes',#8775,$,$); +#8781=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_29','Fire protection safes',#8775,$,$); +#8782=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_30','Firearm security cabinets',#8775,$,$); +#8783=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_31','Floorboard safes',#8775,$,$); +#8784=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_36','High security safes',#8775,$,$); +#8785=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_38','Home and office safes',#8775,$,$); +#8786=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_39','Hotel safes',#8775,$,$); +#8787=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_45','Key safes',#8775,$,$); +#8788=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_49','Lead security cabinets',#8775,$,$); +#8789=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_51','Medical safes',#8775,$,$); +#8790=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_55','Multi-purpose security cabinets',#8775,$,$); +#8791=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_60','Parcel safes',#8775,$,$); +#8792=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_63','Plate safes',#8775,$,$); +#8793=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_76','Secure rooms',#8775,$,$); +#8794=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_84','Steel security cabinets',#8775,$,$); +#8795=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_90','Tool vaults',#8775,$,$); +#8796=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_93','Underfloor safes',#8775,$,$); +#8797=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_94','Vault doors',#8775,$,$); +#8798=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_75_96','Wall safes',#8775,$,$); +#8799=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78','Shelves and storage units',#8566,$,$); +#8800=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_01','Airing cabinets',#8799,$,$); +#8801=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_02','Archive shelves',#8799,$,$); +#8802=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_03','Bathroom cabinets',#8799,$,$); +#8803=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_05','Bathroom furniture',#8799,$,$); +#8804=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_06','Bathroom shelves',#8799,$,$); +#8805=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_07','Bedside units',#8799,$,$); +#8806=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_08','Bottle racks',#8799,$,$); +#8807=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_09','Bowl and bucket holders',#8799,$,$); +#8808=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_11','Chests',#8799,$,$); +#8809=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_12','Classroom storage units',#8799,$,$); +#8810=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_13','Cloakroom units',#8799,$,$); +#8811=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_14','Clothes drying cabinets',#8799,$,$); +#8812=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_15','Clothes hooks',#8799,$,$); +#8813=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_16','Coat hooks',#8799,$,$); +#8814=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_17','Coat racks',#8799,$,$); +#8815=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_18','College bedroom shelves',#8799,$,$); +#8816=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_19','Commercial kitchen shelving and racking units',#8799,$,$); +#8817=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_20','Copyholders',#8799,$,$); +#8818=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_21','Couch roll holders',#8799,$,$); +#8819=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_22','Credenzas',#8799,$,$); +#8820=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_23','Desk tidies',#8799,$,$); +#8821=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_24','Display cases',#8799,$,$); +#8822=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_25','Drawer units',#8799,$,$); +#8823=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_26','Dressers',#8799,$,$); +#8824=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_27','Equipment storage racks',#8799,$,$); +#8825=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_28','External storage units',#8799,$,$); +#8826=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_29','Filing cabinets',#8799,$,$); +#8827=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_30','Folding tables storage cabinets',#8799,$,$); +#8828=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_33','Glazed bookcases',#8799,$,$); +#8829=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_40','Index storage units',#8799,$,$); +#8830=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_41','In-the-round display cases',#8799,$,$); +#8831=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_42','Kitchen drawer units',#8799,$,$); +#8832=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_43','Kitchen bench cupboards',#8799,$,$); +#8833=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_44','Kitchen overhead cupboards',#8799,$,$); +#8834=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_45','Kitchen storage units',#8799,$,$); +#8835=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_46','Laboratory storage units',#8799,$,$); +#8836=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_47','Library shelf units',#8799,$,$); +#8837=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_48','Lockers',#8799,$,$); +#8838=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_51','Media wall partition units',#8799,$,$); +#8839=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_53','Movable aisle storage units',#8799,$,$); +#8840=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_55','Museum showcases',#8799,$,$); +#8841=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_57','Office storage units',#8799,$,$); +#8842=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_58','Open bookcases',#8799,$,$); +#8843=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_63','Plan chests',#8799,$,$); +#8844=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_65','Post room racks',#8799,$,$); +#8845=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_70','Refrigerated mortuary storage units',#8799,$,$); +#8846=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_71','Retail shelf units',#8799,$,$); +#8847=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_72','Retail storage units',#8799,$,$); +#8848=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_73','Rotary storage units',#8799,$,$); +#8849=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_76','Security cages',#8799,$,$); +#8850=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_77','Shelf units',#8799,$,$); +#8851=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_78','Shelves',#8799,$,$); +#8852=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_79','Shelf and racking units',#8799,$,$); +#8853=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_80','Shoe trees',#8799,$,$); +#8854=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_81','Sideboards',#8799,$,$); +#8855=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_84','Storage carousels',#8799,$,$); +#8856=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_85','Storage chests',#8799,$,$); +#8857=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_86','Storage wall partition units',#8799,$,$); +#8858=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_87','Suspension storage units',#8799,$,$); +#8859=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_88','Table storage credenzas',#8799,$,$); +#8860=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_90','Tool chests',#8799,$,$); +#8861=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_93','Under-bed storage units',#8799,$,$); +#8862=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_95','Wardrobe rails',#8799,$,$); +#8863=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_96','Wardrobes',#8799,$,$); +#8864=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_78_97','Weights storage racks',#8799,$,$); +#8865=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_80','Skateboard installations',#8566,$,$); +#8866=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_80_75','Skate bowls',#8865,$,$); +#8867=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_80_77','Skate edges',#8865,$,$); +#8868=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_80_78','Skate pipes',#8865,$,$); +#8869=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_80_80','Skate platforms',#8865,$,$); +#8870=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_80_81','Skate rails',#8865,$,$); +#8871=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_80_82','Skate ramps',#8865,$,$); +#8872=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_80_83','Skate stairs',#8865,$,$); +#8873=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_83','Sports fittings',#8566,$,$); +#8874=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_83_08','Basketball hoops',#8873,$,$); +#8875=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_83_10','Bouldering holds',#8873,$,$); +#8876=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_83_11','Bouldering walls',#8873,$,$); +#8877=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_83_14','Climbing walls',#8873,$,$); +#8878=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_83_37','Hanging and stretching equipment',#8873,$,$); +#8879=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84','Sports goals',#8566,$,$); +#8880=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_04','American football goal posts',#8879,$,$); +#8881=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_05','Australian football goal posts',#8879,$,$); +#8882=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_28','Five-a-side football goals',#8879,$,$); +#8883=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_29','Fixed water polo goals',#8879,$,$); +#8884=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_30','Floating water polo goals',#8879,$,$); +#8885=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_31','Football goals',#8879,$,$); +#8886=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_33','Gaelic football goal posts',#8879,$,$); +#8887=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_36','Handball goals',#8879,$,$); +#8888=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_39','Hockey goals',#8879,$,$); +#8889=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_40','Ice hockey goals',#8879,$,$); +#8890=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_46','Lacrosse goals',#8879,$,$); +#8891=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_56','Netball goals',#8879,$,$); +#8892=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_65','Polo goal posts',#8879,$,$); +#8893=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_69','Quidditch goals',#8879,$,$); +#8894=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_84_74','Rugby goal posts',#8879,$,$); +#8895=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_85','Sports netting',#8566,$,$); +#8896=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_85_04','Archery nets',#8895,$,$); +#8897=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_85_06','Badminton nets',#8895,$,$); +#8898=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_85_17','Cricket nets',#8895,$,$); +#8899=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_85_24','Driving range nets',#8895,$,$); +#8900=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_85_34','Golf course nets',#8895,$,$); +#8901=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_85_80','Space nets',#8895,$,$); +#8902=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_85_85','Stadium nets',#8895,$,$); +#8903=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_85_87','Tennis nets',#8895,$,$); +#8904=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_85_95','Volleyball nets',#8895,$,$); +#8905=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86','Swimming pool fittings',#8566,$,$); +#8906=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86_22','Diving platforms',#8905,$,$); +#8907=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86_24','Diving springboards',#8905,$,$); +#8908=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86_28','False start posts',#8905,$,$); +#8909=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86_30','Fixed domestic diving boards',#8905,$,$); +#8910=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86_32','Fixed starting platforms',#8905,$,$); +#8911=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86_47','Lane rope storage floor cover plates',#8905,$,$); +#8912=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86_59','Pool rails',#8905,$,$); +#8913=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86_78','Small water flumes',#8905,$,$); +#8914=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86_80','Small water slides',#8905,$,$); +#8915=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86_88','Touch panels',#8905,$,$); +#8916=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86_90','Turning boards',#8905,$,$); +#8917=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86_95','Water polo catwalks',#8905,$,$); +#8918=IFCCLASSIFICATIONREFERENCE($,'Pr_40_30_86_96','Water polo field markers',#8905,$,$); +#8919=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50','Furnishings',#8346,$,$); +#8920=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05','Artworks',#8919,$,$); +#8921=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_02','Acrylic paintings',#8920,$,$); +#8922=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_11','Carvings',#8920,$,$); +#8923=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_13','Chalk drawings',#8920,$,$); +#8924=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_14','Charcoal drawings',#8920,$,$); +#8925=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_24','Drypoint prints',#8920,$,$); +#8926=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_27','Embroideries',#8920,$,$); +#8927=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_28','Etchings',#8920,$,$); +#8928=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_29','Floor-mounted mobiles',#8920,$,$); +#8929=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_30','Floor-mounted sculptures',#8920,$,$); +#8930=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_33','Garden ornaments',#8920,$,$); +#8931=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_41','Indoor ornaments',#8920,$,$); +#8932=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_42','Installation pieces',#8920,$,$); +#8933=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_43','Interactive artworks',#8920,$,$); +#8934=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_46','Linoprints',#8920,$,$); +#8935=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_51','Mixed media artworks',#8920,$,$); +#8936=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_55','Murals',#8920,$,$); +#8937=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_58','Oil paintings',#8920,$,$); +#8938=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_60','Pastel drawings',#8920,$,$); +#8939=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_62','Pencil drawings',#8920,$,$); +#8940=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_66','Projected artworks',#8920,$,$); +#8941=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_76','Screenprints',#8920,$,$); +#8942=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_77','Sculptural reliefs',#8920,$,$); +#8943=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_82','Sons et lumi\X2\00E9\X0\res',#8920,$,$); +#8944=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_84','Stand-mounted sculptures',#8920,$,$); +#8945=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_85','Statuary',#8920,$,$); +#8946=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_86','Suspended mobiles',#8920,$,$); +#8947=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_87','Tapestries',#8920,$,$); +#8948=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_95','Wall hangings',#8920,$,$); +#8949=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_96','Wall-mounted sculptures',#8920,$,$); +#8950=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_05_97','Watercolour paintings',#8920,$,$); +#8951=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06','Beds',#8919,$,$); +#8952=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_10','Bunk beds',#8951,$,$); +#8953=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_11','Camp beds',#8951,$,$); +#8954=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_14','Chair beds',#8951,$,$); +#8955=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_16','Cots',#8951,$,$); +#8956=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_18','Cradles',#8951,$,$); +#8957=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_22','Divans',#8951,$,$); +#8958=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_24','Double beds',#8951,$,$); +#8959=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_30','Foldaway beds',#8951,$,$); +#8960=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_31','Four-poster beds',#8951,$,$); +#8961=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_32','Futons',#8951,$,$); +#8962=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_36','Hammocks',#8951,$,$); +#8963=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_37','Headboards',#8951,$,$); +#8964=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_38','Hospital bedheads',#8951,$,$); +#8965=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_39','Hospital beds',#8951,$,$); +#8966=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_50','Mattresses',#8951,$,$); +#8967=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_77','Single beds',#8951,$,$); +#8968=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_06_96','Waterbeds',#8951,$,$); +#8969=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07','Bins and buckets',#8919,$,$); +#8970=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_02','Aggregate bins',#8969,$,$); +#8971=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_04','Ashtrays',#8969,$,$); +#8972=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_07','Bin stores',#8969,$,$); +#8973=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_10','Bulk storage fire sand bins',#8969,$,$); +#8974=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_12','Cemetery flower baskets',#8969,$,$); +#8975=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_19','Compost bins',#8969,$,$); +#8976=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_22','Disposal containers',#8969,$,$); +#8977=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_25','Dustbins',#8969,$,$); +#8978=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_33','Galvanized steel fire buckets',#8969,$,$); +#8979=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_35','Grit bins',#8969,$,$); +#8980=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_46','Linen containers',#8969,$,$); +#8981=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_47','Litter bins',#8969,$,$); +#8982=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_56','Nappy disposal bins',#8969,$,$); +#8983=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_57','Needle disposal boxes',#8969,$,$); +#8984=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_58','Non-segregated waste bins',#8969,$,$); +#8985=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_64','Plastics fire buckets',#8969,$,$); +#8986=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_70','Recycling bins',#8969,$,$); +#8987=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_71','Refuse bag holders',#8969,$,$); +#8988=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_72','Refuse bins',#8969,$,$); +#8989=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_75','Salt bins',#8969,$,$); +#8990=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_76','Sanitary towel disposal bins',#8969,$,$); +#8991=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_77','Segregated waste bins',#8969,$,$); +#8992=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_07_96','Waste bins',#8969,$,$); +#8993=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12','Chairs, seats and benches',#8919,$,$); +#8994=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_03','Armrests',#8993,$,$); +#8995=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_04','Assembly stacking chairs',#8993,$,$); +#8996=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_05','Auditorium chairs',#8993,$,$); +#8997=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_06','Barbell benches',#8993,$,$); +#8998=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_07','Benches',#8993,$,$); +#8999=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_12','Ceremonial chairs',#8993,$,$); +#9000=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_14','Chaises longue',#8993,$,$); +#9001=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_15','Changing benches',#8993,$,$); +#9002=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_16','Classroom seats',#8993,$,$); +#9003=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_20','Deck chairs',#8993,$,$); +#9004=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_21','Dining benches',#8993,$,$); +#9005=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_22','Dining chairs',#8993,$,$); +#9006=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_26','Easy chairs',#8993,$,$); +#9007=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_27','Electrically operated chairs',#8993,$,$); +#9008=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_30','Flip-up seats',#8993,$,$); +#9009=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_31','Folding chairs',#8993,$,$); +#9010=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_32','Footrests',#8993,$,$); +#9011=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_33','Garden benches',#8993,$,$); +#9012=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_37','High chairs',#8993,$,$); +#9013=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_46','Library chairs',#8993,$,$); +#9014=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_47','Linked seats',#8993,$,$); +#9015=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_48','Lounge chairs',#8993,$,$); +#9016=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_51','Meeting room chairs',#8993,$,$); +#9017=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_57','Office chairs',#8993,$,$); +#9018=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_59','Ottomans',#8993,$,$); +#9019=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_62','Pews',#8993,$,$); +#9020=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_63','Play chairs',#8993,$,$); +#9021=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_64','Portable observation poolside chairs',#8993,$,$); +#9022=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_71','Reception chairs',#8993,$,$); +#9023=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_72','Reclining chairs',#8993,$,$); +#9024=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_74','Rocking chairs',#8993,$,$); +#9025=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_76','Settees',#8993,$,$); +#9026=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_80','Sofa beds',#8993,$,$); +#9027=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_81','Sofas',#8993,$,$); +#9028=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_82','Stacking benches',#8993,$,$); +#9029=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_83','Stacking chairs',#8993,$,$); +#9030=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_84','Stacking pews',#8993,$,$); +#9031=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_85','Stools',#8993,$,$); +#9032=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_86','Study chairs',#8993,$,$); +#9033=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_87','Swing chairs',#8993,$,$); +#9034=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_88','Tennis umpire''s stands',#8993,$,$); +#9035=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_93','Upholstered benches',#8993,$,$); +#9036=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_12_94','Utility weight benches',#8993,$,$); +#9037=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_13','Clocks',#8919,$,$); +#9038=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_13_06','Battery analogue clocks',#9037,$,$); +#9039=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_13_22','Digital clocks',#9037,$,$); +#9040=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_13_26','Electric clocks',#9037,$,$); +#9041=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_13_29','Flip clocks',#9037,$,$); +#9042=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_13_51','Mechanical clocks',#9037,$,$); +#9043=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_13_61','Pendulum clocks',#9037,$,$); +#9044=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_13_66','Projection clocks',#9037,$,$); +#9045=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_13_70','Quartz clocks',#9037,$,$); +#9046=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_13_71','Radio clocks',#9037,$,$); +#9047=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_13_86','Sundials',#9037,$,$); +#9048=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_13_89','Torsion pendulum clocks',#9037,$,$); +#9049=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_13_96','Water clocks',#9037,$,$); +#9050=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21','Desks, tables and worktops',#8919,$,$); +#9051=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_05','Audio-visual tables',#9050,$,$); +#9052=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_08','Boardroom tables',#9050,$,$); +#9053=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_10','Bureaux',#9050,$,$); +#9054=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_11','Cable-managed podium tables',#9050,$,$); +#9055=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_13','Classroom desks and tables',#9050,$,$); +#9056=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_14','Coffee tables',#9050,$,$); +#9057=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_15','Conference tables',#9050,$,$); +#9058=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_16','Console tables',#9050,$,$); +#9059=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_17','Computer desks',#9050,$,$); +#9060=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_21','Desks',#9050,$,$); +#9061=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_22','Dining tables',#9050,$,$); +#9062=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_23','Display case tables',#9050,$,$); +#9063=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_24','Drafting machines',#9050,$,$); +#9064=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_25','Drawing boards',#9050,$,$); +#9065=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_26','Dressing tables',#9050,$,$); +#9066=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_29','Flip-top tables',#9050,$,$); +#9067=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_30','Folding dining room tables',#9050,$,$); +#9068=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_31','Folding tables',#9050,$,$); +#9069=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_32','Food preparation tables',#9050,$,$); +#9070=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_33','Gallery benches',#9050,$,$); +#9071=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_44','Kitchenettes',#9050,$,$); +#9072=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_45','Kitchen worktops',#9050,$,$); +#9073=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_46','Laboratory work benches and tables',#9050,$,$); +#9074=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_47','Laundry finishing tables',#9050,$,$); +#9075=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_48','Laundry spotting tables',#9050,$,$); +#9076=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_49','Light tables',#9050,$,$); +#9077=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_50','Manicure finishing tables',#9050,$,$); +#9078=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_51','Meeting room tables',#9050,$,$); +#9079=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_58','Occasional tables',#9050,$,$); +#9080=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_59','Office desks',#9050,$,$); +#9081=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_60','Office tables',#9050,$,$); +#9082=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_63','Play tables',#9050,$,$); +#9083=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_70','Reading desks',#9050,$,$); +#9084=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_73','Reference and search desks',#9050,$,$); +#9085=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_76','School art, design and technology tables',#9050,$,$); +#9086=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_84','Stand-up tables',#9050,$,$); +#9087=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_85','Study desks',#9050,$,$); +#9088=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_90','Touchdown desks',#9050,$,$); +#9089=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_96','Workstations',#9050,$,$); +#9090=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_98','Writing desks',#9050,$,$); +#9091=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_21_99','Writing tablets (detachable)',#9050,$,$); +#9092=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_28','Extinguishers and fire blankets',#8919,$,$); +#9093=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_28_11','Carbon dioxide fire extinguishers',#9092,$,$); +#9094=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_28_12','Carbon steel fire buckets',#9092,$,$); +#9095=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_28_24','Dry powder fire extinguishers',#9092,$,$); +#9096=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_28_28','Extinguisher floor stands',#9092,$,$); +#9097=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_28_29','Fire protective blankets',#9092,$,$); +#9098=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_28_30','Foam fire extinguishers',#9092,$,$); +#9099=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_28_31','Fire suppression liquid',#9092,$,$); +#9100=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_28_47','Heat protective blankets',#9092,$,$); +#9101=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_28_64','Portable fire extinguishers',#9092,$,$); +#9102=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_28_96','Water fire extinguishers',#9092,$,$); +#9103=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_28_97','Wet chemical fire extinguishers',#9092,$,$); +#9104=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_31','Furniture booths',#8919,$,$); +#9105=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_31_51','Meeting booths',#9104,$,$); +#9106=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_31_71','Restaurant booths',#9104,$,$); +#9107=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_33','Garden furnishings',#8919,$,$); +#9108=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_33_33','Garden awnings',#9107,$,$); +#9109=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_33_34','Garden umbrellas',#9107,$,$); +#9110=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51','Medical chairs and couches',#8919,$,$); +#9111=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_05','Bariatric patient chairs',#9110,$,$); +#9112=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_06','Bariatric plinth couches',#9110,$,$); +#9113=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_07','Blood sampling chairs',#9110,$,$); +#9114=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_08','Bo-plinth couches',#9110,$,$); +#9115=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_15','Commodes',#9110,$,$); +#9116=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_21','Day care couches',#9110,$,$); +#9117=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_22','Dental chairs',#9110,$,$); +#9118=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_23','Dialysis chairs',#9110,$,$); +#9119=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_25','Echocardiography couches',#9110,$,$); +#9120=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_26','Ear, nose and throat (ENT) and ophthalmic chairs',#9110,$,$); +#9121=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_27','Examination and treatment chairs',#9110,$,$); +#9122=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_28','Examination and treatment couches',#9110,$,$); +#9123=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_31','Foot stools',#9110,$,$); +#9124=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_34','Gynaecology chairs',#9110,$,$); +#9125=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_35','Gynaecology couches',#9110,$,$); +#9126=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_51','Minor operations couches',#9110,$,$); +#9127=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_58','Oncology chairs',#9110,$,$); +#9128=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_59','Outpatients couches',#9110,$,$); +#9129=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_61','Phlebotomy chairs',#9110,$,$); +#9130=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_62','Phlebotomy couches',#9110,$,$); +#9131=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_63','Plaster chairs',#9110,$,$); +#9132=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_65','Podiatry chairs',#9110,$,$); +#9133=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_71','Reclining treatment armchairs',#9110,$,$); +#9134=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_75','Sanitary seats',#9110,$,$); +#9135=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_84','Step stools',#9110,$,$); +#9136=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_51_92','Ultrasound couches',#9110,$,$); +#9137=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_52','Medical desks, tables and worktops',#8919,$,$); +#9138=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_52_22','Dissection tables',#9137,$,$); +#9139=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_52_50','Mayo tables',#9137,$,$); +#9140=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_52_57','Operating theatre tables',#9137,$,$); +#9141=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_52_58','Overbed tables',#9137,$,$); +#9142=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_52_59','Overchair tables',#9137,$,$); +#9143=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_52_65','Post-mortem tables',#9137,$,$); +#9144=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_52_88','Tilt tables',#9137,$,$); +#9145=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53','Medical trolleys',#8919,$,$); +#9146=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53_04','Armchair patient trolleys',#9145,$,$); +#9147=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53_06','Bariatric patient trolleys',#9145,$,$); +#9148=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53_24','Dressing trolleys',#9145,$,$); +#9149=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53_27','Emergency trolleys',#9145,$,$); +#9150=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53_33','General purpose medical trolleys',#9145,$,$); +#9151=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53_41','Instruments trolleys',#9145,$,$); +#9152=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53_48','Lockable hospital trolleys',#9145,$,$); +#9153=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53_51','Medical service carts',#9145,$,$); +#9154=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53_60','Patient notes trolleys',#9145,$,$); +#9155=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53_61','Patient trolleys',#9145,$,$); +#9156=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53_62','Phlebotomy trolleys',#9145,$,$); +#9157=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53_66','Procedure trolleys',#9145,$,$); +#9158=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_53_81','Soiled linen trolleys',#9145,$,$); +#9159=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81','Soft furnishings',#8919,$,$); +#9160=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_06','Beanbags',#9159,$,$); +#9161=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_07','Blankets',#9159,$,$); +#9162=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_20','Cushions',#9159,$,$); +#9163=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_25','Duvets',#9159,$,$); +#9164=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_29','Flannels',#9159,$,$); +#9165=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_56','Napkins',#9159,$,$); +#9166=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_62','Pillows',#9159,$,$); +#9167=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_63','Placemats',#9159,$,$); +#9168=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_73','Rugs',#9159,$,$); +#9169=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_74','Runners',#9159,$,$); +#9170=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_77','Sheets',#9159,$,$); +#9171=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_86','Swags',#9159,$,$); +#9172=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_87','Tablecloths',#9159,$,$); +#9173=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_90','Towels',#9159,$,$); +#9174=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_91','Trimmings',#9159,$,$); +#9175=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_81_94','Valances',#9159,$,$); +#9176=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_83','Sports furnishings',#8919,$,$); +#9177=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_83_06','Balancing equipment',#9176,$,$); +#9178=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_83_19','Cricket wicket stump boxes',#9176,$,$); +#9179=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_83_20','Cycle ramps',#9176,$,$); +#9180=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_83_28','Equestrian riding equipment',#9176,$,$); +#9181=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_83_29','Fencing pistes',#9176,$,$); +#9182=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_83_44','Jumping equipment',#9176,$,$); +#9183=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_84','Stands',#8919,$,$); +#9184=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_84_09','Bowl stands',#9183,$,$); +#9185=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_84_23','Display banner stands',#9183,$,$); +#9186=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_84_28','Exhibit stands',#9183,$,$); +#9187=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_84_36','Hat stands',#9183,$,$); +#9188=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_84_42','Infusion stands',#9183,$,$); +#9189=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_84_51','Medical equipment stands',#9183,$,$); +#9190=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_84_66','Print stands',#9183,$,$); +#9191=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_84_92','Umbrella stands',#9183,$,$); +#9192=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_86','Swimming pool furnishings',#8919,$,$); +#9193=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_86_46','Lane rope storage bags',#9192,$,$); +#9194=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_86_62','Portable domestic diving boards',#9192,$,$); +#9195=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_86_64','Portable starting platforms',#9192,$,$); +#9196=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_86_66','Private use pool covers',#9192,$,$); +#9197=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_86_68','Public use pool covers',#9192,$,$); +#9198=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90','Trolleys',#8919,$,$); +#9199=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_08','Book trolleys',#9198,$,$); +#9200=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_15','Computer trolleys',#9198,$,$); +#9201=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_30','Fire trolleys',#9198,$,$); +#9202=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_31','Food preparation trolleys',#9198,$,$); +#9203=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_32','Food service trolleys',#9198,$,$); +#9204=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_33','Furniture trolleys',#9198,$,$); +#9205=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_46','Laundry trolleys',#9198,$,$); +#9206=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_47','Laundry bag trolleys',#9198,$,$); +#9207=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_49','Luggage trolleys',#9198,$,$); +#9208=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_52','Mailroom trolleys',#9198,$,$); +#9209=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_64','Pool lane rope storage trolleys',#9198,$,$); +#9210=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_72','Relay break detector storage trolleys',#9198,$,$); +#9211=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_76','Shopping trolleys',#9198,$,$); +#9212=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_82','Spa treatment trolleys',#9198,$,$); +#9213=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_87','Table storage trolleys',#9198,$,$); +#9214=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_90_88','Touchpad storage trolleys',#9198,$,$); +#9215=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_96','Wheels',#8919,$,$); +#9216=IFCCLASSIFICATIONREFERENCE($,'Pr_40_50_96_11','Castors',#9215,$,$); +#9217=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70','Equipment',#8346,$,$); +#9218=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_05','Audio visual equipment',#9217,$,$); +#9219=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_05_70','Radios',#9218,$,$); +#9220=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_05_88','Televisions',#9218,$,$); +#9221=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_13','Cleaning equipment',#9217,$,$); +#9222=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_13_50','Machine parts cleaning washer units',#9221,$,$); +#9223=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_13_58','Oil spillage cleaning units',#9221,$,$); +#9224=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_13_60','Orbital tank cleaners',#9221,$,$); +#9225=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_13_72','Robotic cleaning units',#9221,$,$); +#9226=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_15','Cold water supply sources',#9217,$,$); +#9227=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_15_24','Drinking fountains',#9226,$,$); +#9228=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_15_96','Water coolers',#9226,$,$); +#9229=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_21','Dishwashers',#9217,$,$); +#9230=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_21_16','Conveyor dishwashers',#9229,$,$); +#9231=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_21_22','Dish and utensil washers',#9229,$,$); +#9232=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_21_24','Domestic dishwashers',#9229,$,$); +#9233=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_21_30','Flight dishwashers',#9229,$,$); +#9234=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_21_60','Pass-through dishwashers',#9229,$,$); +#9235=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_21_92','Under-counter dishwashers',#9229,$,$); +#9236=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22','Dispensers and acceptance units',#9217,$,$); +#9237=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_05','Automated teller machines',#9236,$,$); +#9238=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_06','Barrier parking control units',#9236,$,$); +#9239=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_11','Cash dispensers',#9236,$,$); +#9240=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_15','Cold drink dispensers',#9236,$,$); +#9241=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_16','Collection boxes',#9236,$,$); +#9242=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_17','Condom dispensers',#9236,$,$); +#9243=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_22','Disposable apron dispensers',#9236,$,$); +#9244=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_23','Disposable glove dispensers',#9236,$,$); +#9245=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_24','Donation boxes',#9236,$,$); +#9246=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_25','Drive-by cash payment units',#9236,$,$); +#9247=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_29','Facial tissue dispensers',#9236,$,$); +#9248=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_31','Food waste disposal units',#9236,$,$); +#9249=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_36','Hand cleaning gel dispensers',#9236,$,$); +#9250=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_37','Hot drink dispensers',#9236,$,$); +#9251=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_38','Hot food dispensers',#9236,$,$); +#9252=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_47','Leaflet dispensers',#9236,$,$); +#9253=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_52','Multi-function dispensers',#9236,$,$); +#9254=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_56','Newspaper dispensers',#9236,$,$); +#9255=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_60','Packaged goods dispensers',#9236,$,$); +#9256=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_61','Paper roll dispensers',#9236,$,$); +#9257=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_62','Paper towel dispensers',#9236,$,$); +#9258=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_63','Parking meters',#9236,$,$); +#9259=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_64','Pay and display units',#9236,$,$); +#9260=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_66','Plate dispensers',#9236,$,$); +#9261=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_71','Refreshment dispensers',#9236,$,$); +#9262=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_75','Sanitary towel dispensers',#9236,$,$); +#9263=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_77','Shaving product dispensers',#9236,$,$); +#9264=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_80','Snack dispensers',#9236,$,$); +#9265=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_81','Soap dispensers',#9236,$,$); +#9266=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_85','Surface wipes dispensers',#9236,$,$); +#9267=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_86','Sweets dispensers',#9236,$,$); +#9268=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_88','Ticket dispensers',#9236,$,$); +#9269=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_90','Toilet paper dispensers',#9236,$,$); +#9270=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_22_92','Tool dispensers',#9236,$,$); +#9271=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23','Display and service catering products',#9217,$,$); +#9272=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23_06','Bains-marie',#9271,$,$); +#9273=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23_24','Drinks chillers',#9271,$,$); +#9274=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23_27','Espresso machines',#9271,$,$); +#9275=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23_31','Food display units',#9271,$,$); +#9276=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23_33','Food sneeze guards',#9271,$,$); +#9277=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23_40','Icemakers',#9271,$,$); +#9278=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23_42','Instant boiling and cold water taps',#9271,$,$); +#9279=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23_53','Mobile bains-marie',#9271,$,$); +#9280=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23_54','Mobile plain top hot cupboards',#9271,$,$); +#9281=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23_71','Refrigerated display cabinets',#9271,$,$); +#9282=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23_72','Refrigerated display counters',#9271,$,$); +#9283=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23_84','Static plain top hot cupboards',#9271,$,$); +#9284=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_23_86','Sushi trains',#9271,$,$); +#9285=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24','Domestic cooking equipment',#9217,$,$); +#9286=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24_07','Built-in electric hobs',#9285,$,$); +#9287=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24_08','Built-in electric ovens',#9285,$,$); +#9288=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24_09','Built-in gas hobs',#9285,$,$); +#9289=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24_10','Built-in gas ovens',#9285,$,$); +#9290=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24_11','Built-in microwave ovens',#9285,$,$); +#9291=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24_15','Combination microwave ovens',#9285,$,$); +#9292=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24_26','Electric barbecues',#9285,$,$); +#9293=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24_27','Electric ranges',#9285,$,$); +#9294=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24_33','Gas barbecues',#9285,$,$); +#9295=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24_34','Gas ranges',#9285,$,$); +#9296=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24_35','Gas free-standing cookers',#9285,$,$); +#9297=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24_45','Kettles',#9285,$,$); +#9298=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_24_81','Solid fuel barbecues',#9285,$,$); +#9299=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_25','Domestic laundry equipment',#9217,$,$); +#9300=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_25_45','Laundry tumble dryers',#9299,$,$); +#9301=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_25_46','Laundry washer-dryers',#9299,$,$); +#9302=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_25_47','Laundry washing machines',#9299,$,$); +#9303=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_27','Environmental protection equipment',#9217,$,$); +#9304=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_27_56','Oil containment booms',#9303,$,$); +#9305=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_29','Fire simulation equipment',#9217,$,$); +#9306=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_29_01','Aircraft fire training simulators',#9305,$,$); +#9307=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_31','Food refrigerators and freezers',#9217,$,$); +#9308=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_31_06','Blast chiller cabinets',#9307,$,$); +#9309=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_31_08','Blast freezer cabinets',#9307,$,$); +#9310=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_31_29','Freezer cabinets',#9307,$,$); +#9311=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_31_30','Freezer counters',#9307,$,$); +#9312=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_31_31','Freezers',#9307,$,$); +#9313=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_31_32','Fridge-freezers',#9307,$,$); +#9314=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_31_70','Refrigerated cabinets',#9307,$,$); +#9315=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_31_71','Refrigerated counters',#9307,$,$); +#9316=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_31_72','Refrigerators',#9307,$,$); +#9317=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_35','General workshop equipment',#9217,$,$); +#9318=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_35_15','Clipping machines',#9317,$,$); +#9319=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_35_35','Guillotines',#9317,$,$); +#9320=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_35_50','Magnetic tool holders',#9317,$,$); +#9321=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_35_60','Packaging machines',#9317,$,$); +#9322=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_35_67','Punch machines',#9317,$,$); +#9323=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_35_77','Shaping machines',#9317,$,$); +#9324=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_35_80','Slotting machines',#9317,$,$); +#9325=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_35_84','Strapping machines',#9317,$,$); +#9326=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_35_88','Threading machines',#9317,$,$); +#9327=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46','Laundry fittings and equipment',#9217,$,$); +#9328=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_24','Dryer ironers',#9327,$,$); +#9329=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_25','Dry work presses',#9327,$,$); +#9330=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_30','Flatwork ironers',#9327,$,$); +#9331=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_31','Form finishers',#9327,$,$); +#9332=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_39','Hydro extractors',#9327,$,$); +#9333=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_42','Ironing tables',#9327,$,$); +#9334=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_45','Laundry cabinets',#9327,$,$); +#9335=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_46','Laundry feeders',#9327,$,$); +#9336=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_47','Laundry folders',#9327,$,$); +#9337=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_48','Laundry recovery tanks',#9327,$,$); +#9338=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_72','Roller ironers',#9327,$,$); +#9339=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_77','Shirt finishers',#9327,$,$); +#9340=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_82','Spotting cabinets',#9327,$,$); +#9341=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_83','Spotting tables',#9327,$,$); +#9342=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_90','Trouser presses',#9327,$,$); +#9343=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_96','Washer extractors',#9327,$,$); +#9344=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_98','Water extraction presses',#9327,$,$); +#9345=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_46_99','Wet work presses',#9327,$,$); +#9346=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_47','Laundry washers and dryers',#9217,$,$); +#9347=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_47_06','Barrier washers',#9346,$,$); +#9348=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_47_07','Batch laundry dryers',#9346,$,$); +#9349=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_47_08','Batch laundry washers',#9346,$,$); +#9350=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_47_32','Front-loading washers',#9346,$,$); +#9351=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_47_46','Laundry dryers',#9346,$,$); +#9352=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_47_75','Sanitary barrier washers',#9346,$,$); +#9353=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_47_91','Tumble dryers',#9346,$,$); +#9354=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_47_97','Washer dryers',#9346,$,$); +#9355=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_50','Mail equipment',#9217,$,$); +#9356=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_50_32','Franking machines',#9355,$,$); +#9357=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_50_65','Post handling equipment',#9355,$,$); +#9358=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51','Medical and laboratory equipment',#9217,$,$); +#9359=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_04','Autoclaves',#9358,$,$); +#9360=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_10','Calorimeters',#9358,$,$); +#9361=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_16','Contamination control equipment',#9358,$,$); +#9362=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_22','Defibrillator units',#9358,$,$); +#9363=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_30','Fermenters',#9358,$,$); +#9364=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_32','First aid kits',#9358,$,$); +#9365=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_42','Incubators',#9358,$,$); +#9366=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_44','Jacketed vessels',#9358,$,$); +#9367=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_51','Microscopes',#9358,$,$); +#9368=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_59','Operating theatre equipment',#9358,$,$); +#9369=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_60','Oscilloscopes',#9358,$,$); +#9370=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_70','Retrievers',#9358,$,$); +#9371=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_84','Sterilisation equipment',#9358,$,$); +#9372=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_51_94','Vacuum furnaces',#9358,$,$); +#9373=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_55','Mooring and docking equipment',#9217,$,$); +#9374=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_55_05','Arch fenders',#9373,$,$); +#9375=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_55_15','Capstan',#9373,$,$); +#9376=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_55_20','Cone fenders',#9373,$,$); +#9377=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_55_22','Cell fenders',#9373,$,$); +#9378=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_55_50','Magnetic mooring devices',#9373,$,$); +#9379=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_55_53','Mooring line tensioners',#9373,$,$); +#9380=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_55_61','Pneumatic fenders',#9373,$,$); +#9381=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_55_69','Quick release mooring hooks',#9373,$,$); +#9382=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_55_95','Vacuum mooring devices',#9373,$,$); +#9383=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_58','Office equipment',#9217,$,$); +#9384=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_58_23','Document shredders',#9383,$,$); +#9385=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_58_46','Label makers',#9383,$,$); +#9386=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_58_60','Paper laminators',#9383,$,$); +#9387=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_62','Personal dryers',#9217,$,$); +#9388=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_62_09','Body dryers',#9387,$,$); +#9389=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_62_29','Face dryers',#9387,$,$); +#9390=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_62_36','Hairdryers',#9387,$,$); +#9391=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_62_37','Hand dryers',#9387,$,$); +#9392=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_63','Photographic equipment',#9217,$,$); +#9393=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_63_04','Automated film developing equipment',#9392,$,$); +#9394=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_63_05','Automated printing equipment',#9392,$,$); +#9395=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_63_28','Enlargers',#9392,$,$); +#9396=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_63_35','Graphics cameras',#9392,$,$); +#9397=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65','Preparation catering equipment',#9217,$,$); +#9398=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_16','Conveyor toasters',#9397,$,$); +#9399=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_17','Drink making equipment',#9397,$,$); +#9400=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_18','Electric boiling pans',#9397,$,$); +#9401=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_19','Electric boiling tables',#9397,$,$); +#9402=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_20','Electric bratt pans',#9397,$,$); +#9403=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_21','Electric cooking ranges',#9397,$,$); +#9404=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_22','Electric deep fat fryers',#9397,$,$); +#9405=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_23','Electric fryers',#9397,$,$); +#9406=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_24','Electric griddles',#9397,$,$); +#9407=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_25','Electric grills',#9397,$,$); +#9408=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_26','Electric hot water dispensers',#9397,$,$); +#9409=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_27','Electric ovens',#9397,$,$); +#9410=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_28','Electric steaming ovens',#9397,$,$); +#9411=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_29','Food blenders',#9397,$,$); +#9412=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_30','Food mincers',#9397,$,$); +#9413=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_31','Food mixers',#9397,$,$); +#9414=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_32','Food smokers',#9397,$,$); +#9415=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_33','Gas boiling pans',#9397,$,$); +#9416=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_34','Gas boiling tables',#9397,$,$); +#9417=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_35','Gas bratt pans',#9397,$,$); +#9418=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_36','Gas cooking ranges',#9397,$,$); +#9419=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_37','Gas deep fat fryers',#9397,$,$); +#9420=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_38','Gas fryers',#9397,$,$); +#9421=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_39','Gas griddles',#9397,$,$); +#9422=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_40','Gas grills',#9397,$,$); +#9423=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_41','Gas ovens',#9397,$,$); +#9424=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_42','Gas steaming ovens',#9397,$,$); +#9425=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_43','General purpose electric ovens',#9397,$,$); +#9426=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_44','General purpose gas ovens',#9397,$,$); +#9427=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_45','Gravity feed slicers',#9397,$,$); +#9428=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_46','Hot cupboards',#9397,$,$); +#9429=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_51','Microwave ovens',#9397,$,$); +#9430=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_65','Potato peelers',#9397,$,$); +#9431=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_79','Slot toasters',#9397,$,$); +#9432=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_65_94','Vegetable preparation machines',#9397,$,$); +#9433=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_67','Projectors',#9217,$,$); +#9434=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_67_14','Cinematic projectors',#9433,$,$); +#9435=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_67_22','Digital projectors',#9433,$,$); +#9436=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_67_29','Film projectors',#9433,$,$); +#9437=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_67_63','Planetarium projectors',#9433,$,$); +#9438=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_67_79','Slide projectors',#9433,$,$); +#9439=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_71','Recreation equipment',#9217,$,$); +#9440=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_71_04','Arcade machines',#9439,$,$); +#9441=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_71_87','Tanning units',#9439,$,$); +#9442=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73','Rolling stock depot equipment',#9217,$,$); +#9443=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_06','Bogie drops',#9442,$,$); +#9444=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_07','Bogie presses',#9442,$,$); +#9445=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_08','Bogie racks',#9442,$,$); +#9446=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_09','Bogie turntables',#9442,$,$); +#9447=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_10','Bogie workstands',#9442,$,$); +#9448=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_23','Drophead buckeye couplers',#9442,$,$); +#9449=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_24','Drophead buckeye drawgears',#9442,$,$); +#9450=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_30','Fixed CETs',#9442,$,$); +#9451=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_47','Lifting tables',#9442,$,$); +#9452=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_70','Rail vehicle lifting jacks',#9442,$,$); +#9453=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_73','Retractable buffers',#9442,$,$); +#9454=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_75','Sand plant',#9442,$,$); +#9455=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_95','Wheel drops',#9442,$,$); +#9456=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_96','Wheel lathes',#9442,$,$); +#9457=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_97','Wheelset presses',#9442,$,$); +#9458=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_73_98','Wheel stops',#9442,$,$); +#9459=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75','Safety equipment',#9217,$,$); +#9460=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_01','Access cradles',#9459,$,$); +#9461=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_27','Electrically powered winches',#9459,$,$); +#9462=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_28','Evacuation chairs',#9459,$,$); +#9463=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_29','Fall arrester devices',#9459,$,$); +#9464=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_33','Gantries',#9459,$,$); +#9465=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_35','Guided type fall arresters',#9459,$,$); +#9466=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_36','Hand climbing devices',#9459,$,$); +#9467=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_37','Harnesses and lanyards',#9459,$,$); +#9468=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_39','Hoist equipment storage units',#9459,$,$); +#9469=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_50','Manual push',#9459,$,$); +#9470=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_51','Manual winches',#9459,$,$); +#9471=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_55','Mullion guides',#9459,$,$); +#9472=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_66','Protection netting',#9459,$,$); +#9473=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_72','Rope and pulley devices',#9459,$,$); +#9474=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_75','Safety access anchor devices',#9459,$,$); +#9475=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_76','Safety access equipment winding handles',#9459,$,$); +#9476=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_77','Safety harnesses',#9459,$,$); +#9477=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_79','Safety netting',#9459,$,$); +#9478=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_81','Spillage control kits',#9459,$,$); +#9479=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_82','Stair climbing trolleys',#9459,$,$); +#9480=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_83','Suspended access tracks',#9459,$,$); +#9481=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_84','Suspended chairs',#9459,$,$); +#9482=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_85','Suspension rigs',#9459,$,$); +#9483=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_86','Suspension rope restraints',#9459,$,$); +#9484=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_96','Working platforms',#9459,$,$); +#9485=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_75_97','Working platform storage units',#9459,$,$); +#9486=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84','Sports equipment',#9217,$,$); +#9487=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_01','Abdominal machines',#9486,$,$); +#9488=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_04','Arm machines',#9486,$,$); +#9489=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_06','Back machines',#9486,$,$); +#9490=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_11','Cable machines',#9486,$,$); +#9491=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_13','Chest and shoulder machines',#9486,$,$); +#9492=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_16','Cross trainers',#9486,$,$); +#9493=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_26','Elliptical trainers',#9486,$,$); +#9494=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_27','Exercise bikes',#9486,$,$); +#9495=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_46','Leg machines',#9486,$,$); +#9496=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_47','Leverage units',#9486,$,$); +#9497=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_55','Multi-gyms',#9486,$,$); +#9498=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_65','Pool, snooker and billiards tables',#9486,$,$); +#9499=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_66','Power cages and racks',#9486,$,$); +#9500=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_67','Power plates',#9486,$,$); +#9501=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_68','Punch bags',#9486,$,$); +#9502=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_72','Rowing machines',#9486,$,$); +#9503=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_80','Smith machines',#9486,$,$); +#9504=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_84','Steppers',#9486,$,$); +#9505=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_86','Suspension trainers',#9486,$,$); +#9506=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_90','Trampolines',#9486,$,$); +#9507=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_91','Treadmills',#9486,$,$); +#9508=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_92','Upper body trainers',#9486,$,$); +#9509=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_84_94','Vertical knee raise and dip machines',#9486,$,$); +#9510=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_85','Stage equipment',#9217,$,$); +#9511=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_85_31','Fly/ pulley bars',#9510,$,$); +#9512=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_86','Swimming pool equipment',#9217,$,$); +#9513=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_86_02','Air cushion equipment',#9512,$,$); +#9514=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_86_08','Buoyancy-aided movable floors',#9512,$,$); +#9515=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_86_10','Buoyancy-aided movable bulkheads',#9512,$,$); +#9516=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_86_52','Mechanical drive movable floors',#9512,$,$); +#9517=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_86_60','Pool structure-supported movable bulkheads',#9512,$,$); +#9518=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_86_84','Surface agitation equipment',#9512,$,$); +#9519=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_86_94','Water polo ball release devices',#9512,$,$); +#9520=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_86_98','Wave machine equipment',#9512,$,$); +#9521=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_96','Water control equipment',#9217,$,$); +#9522=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_96_30','Flow control device chambers',#9521,$,$); +#9523=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_96_31','Flow control devices',#9521,$,$); +#9524=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_99','Weighing equipment',#9217,$,$); +#9525=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_99_22','Digital scales',#9524,$,$); +#9526=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_99_42','Industrial scales',#9524,$,$); +#9527=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_99_45','Kitchen scales',#9524,$,$); +#9528=IFCCLASSIFICATIONREFERENCE($,'Pr_40_70_99_62','Personnel weighing scales',#9524,$,$); +#9529=IFCCLASSIFICATIONREFERENCE($,'Pr_45','Flora and fauna products',#4923,$,$); +#9530=IFCCLASSIFICATIONREFERENCE($,'Pr_45_28','Fauna products',#9529,$,$); +#9531=IFCCLASSIFICATIONREFERENCE($,'Pr_45_28_30','Fish, eel and lamprey pass products',#9530,$,$); +#9532=IFCCLASSIFICATIONREFERENCE($,'Pr_45_28_30_10','Bristle boards and mats',#9531,$,$); +#9533=IFCCLASSIFICATIONREFERENCE($,'Pr_45_28_30_27','Eel tiles',#9531,$,$); +#9534=IFCCLASSIFICATIONREFERENCE($,'Pr_45_28_30_46','Larinier tiles',#9531,$,$); +#9535=IFCCLASSIFICATIONREFERENCE($,'Pr_45_28_30_78','Siphon fish passes',#9531,$,$); +#9536=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30','Flora products',#9529,$,$); +#9537=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_04','Artificial plants',#9536,$,$); +#9538=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_04_02','Artificial grass',#9537,$,$); +#9539=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_04_03','Artificial low growing trees',#9537,$,$); +#9540=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_04_04','Artificial topiary and pleaching',#9537,$,$); +#9541=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_04_05','Artificial trees',#9537,$,$); +#9542=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_04_64','Polyester silk plants',#9537,$,$); +#9543=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_04_66','Preserved plants',#9537,$,$); +#9544=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_10','Bulbs, corms, tubers and dormant roots',#9536,$,$); +#9545=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_10_04','Annual tubers',#9544,$,$); +#9546=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_10_10','Bulbs',#9544,$,$); +#9547=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_10_15','Corms',#9544,$,$); +#9548=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_10_62','Perennial roots',#9544,$,$); +#9549=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_10_63','Perennial tubers',#9544,$,$); +#9550=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_36','Herbaceous and aquatic plants',#9536,$,$); +#9551=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_36_02','Annual plugs',#9550,$,$); +#9552=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_36_03','Aquatic plant bare roots and clumps',#9550,$,$); +#9553=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_36_04','Aquatic plant bunches',#9550,$,$); +#9554=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_36_05','Aquatic plant pots and baskets',#9550,$,$); +#9555=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_36_06','Aquatic plant plugs',#9550,$,$); +#9556=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_36_11','Cell-grown annuals',#9550,$,$); +#9557=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_36_13','Cell-grown perennials',#9550,$,$); +#9558=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_36_14','Container-grown aquatic plants',#9550,$,$); +#9559=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_36_15','Container-grown annuals',#9550,$,$); +#9560=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_36_16','Container-grown perennials',#9550,$,$); +#9561=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_36_64','Perennial clumps',#9550,$,$); +#9562=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_36_65','Perennial plugs',#9550,$,$); +#9563=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_76','Seeds',#9536,$,$); +#9564=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_76_29','Flower seeds',#9563,$,$); +#9565=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_76_32','Fruit seeds',#9563,$,$); +#9566=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_76_34','Grass seeds',#9563,$,$); +#9567=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_76_39','Hydroseeding mixes',#9563,$,$); +#9568=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_76_48','Locally collected seeds',#9563,$,$); +#9569=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_76_77','Site-grown temporary crop seeds',#9563,$,$); +#9570=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_76_90','Tree and shrub seeds',#9563,$,$); +#9571=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_76_94','Vegetable seeds',#9563,$,$); +#9572=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_76_97','Wildflower seeds',#9563,$,$); +#9573=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80','Shrubs and woody climbers',#9536,$,$); +#9574=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80_04','Bare-root climbers',#9573,$,$); +#9575=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80_06','Bare-root cutting-raised roses',#9573,$,$); +#9576=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80_08','Bare-root shrubs',#9573,$,$); +#9577=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80_10','Bare-root budded roses',#9573,$,$); +#9578=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80_11','Cell-grown climbers',#9573,$,$); +#9579=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80_12','Cell-grown shrubs',#9573,$,$); +#9580=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80_14','Container-grown bamboos',#9573,$,$); +#9581=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80_15','Container-grown budded roses',#9573,$,$); +#9582=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80_16','Container-grown climbers',#9573,$,$); +#9583=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80_18','Container-grown cutting-raised roses',#9573,$,$); +#9584=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80_20','Container-grown shrubs',#9573,$,$); +#9585=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80_71','Rootballed bamboos',#9573,$,$); +#9586=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_80_73','Rootballed shrubs',#9573,$,$); +#9587=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_90','Trees',#9536,$,$); +#9588=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_90_05','Bare-root conifers',#9587,$,$); +#9589=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_90_07','Bare-root fruit trees',#9587,$,$); +#9590=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_90_09','Bare-root trees',#9587,$,$); +#9591=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_90_11','Cell-grown conifers',#9587,$,$); +#9592=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_90_13','Cell-grown trees',#9587,$,$); +#9593=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_90_17','Container-grown conifers',#9587,$,$); +#9594=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_90_19','Container-grown fruit trees',#9587,$,$); +#9595=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_90_21','Container-grown trees',#9587,$,$); +#9596=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_90_72','Rootballed conifers',#9587,$,$); +#9597=IFCCLASSIFICATIONREFERENCE($,'Pr_45_30_90_74','Rootballed trees',#9587,$,$); +#9598=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31','Formless flora and fauna products',#9529,$,$); +#9599=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_03','Animal biocides',#9598,$,$); +#9600=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_03_08','Biological controls',#9599,$,$); +#9601=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_03_42','Insecticides',#9599,$,$); +#9602=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_03_64','Poisons',#9599,$,$); +#9603=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_03_72','Rodenticides',#9599,$,$); +#9604=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_03_88','Termite-resistant granules',#9599,$,$); +#9605=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_03_90','Termiticides',#9599,$,$); +#9606=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_03_96','Worm controls',#9599,$,$); +#9607=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_37','Herbicides',#9598,$,$); +#9608=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_37_15','Combined selective lawn herbicide and feed mixes',#9607,$,$); +#9609=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_37_56','Non-selective contact herbicides',#9607,$,$); +#9610=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_37_57','Non-selective residual herbicides',#9607,$,$); +#9611=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_37_58','Non-selective systemic herbicides',#9607,$,$); +#9612=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_37_76','Selective herbicides',#9607,$,$); +#9613=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_52','Microbial biocides',#9598,$,$); +#9614=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_52_03','Algaecides',#9613,$,$); +#9615=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_52_07','Biocides',#9613,$,$); +#9616=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_52_31','Fungicidal solutions',#9613,$,$); +#9617=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_52_32','Fungicides',#9613,$,$); +#9618=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_52_55','Non-oxidizing water treatment biocides',#9613,$,$); +#9619=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_52_59','Oxidizing water treatment biocides',#9613,$,$); +#9620=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_52_62','Plant fungicides',#9613,$,$); +#9621=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_52_73','Root sealers',#9613,$,$); +#9622=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_52_86','Surface biocides',#9613,$,$); +#9623=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_52_97','Vermicides',#9613,$,$); +#9624=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63','Plant-based fibres',#9598,$,$); +#9625=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_14','Coir fibres',#9624,$,$); +#9626=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_15','Combed wheat reed',#9624,$,$); +#9627=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_16','Compostable plant material',#9624,$,$); +#9628=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_30','Flax fibres',#9624,$,$); +#9629=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_37','Hemp fibres',#9624,$,$); +#9630=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_44','Jute fibres',#9624,$,$); +#9631=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_47','Long straw',#9624,$,$); +#9632=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_48','Loose straw',#9624,$,$); +#9633=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_56','Natural bark',#9624,$,$); +#9634=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_60','Paper bales',#9624,$,$); +#9635=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_64','Playground bark',#9624,$,$); +#9636=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_76','Sedge',#9624,$,$); +#9637=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_78','Sisal fibres',#9624,$,$); +#9638=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_80','Sphagnum moss',#9624,$,$); +#9639=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_84','Straw bales',#9624,$,$); +#9640=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_96','Water reed',#9624,$,$); +#9641=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_97','Wood chips',#9624,$,$); +#9642=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_63_98','Wood fibres',#9624,$,$); +#9643=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89','Topsoils, feeds and growing mediums',#9598,$,$); +#9644=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_08','Blood and bonemeal',#9643,$,$); +#9645=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_15','Compost dressings',#9643,$,$); +#9646=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_16','Composted materials',#9643,$,$); +#9647=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_35','Green roof substrates',#9643,$,$); +#9648=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_41','Imported growing mediums',#9643,$,$); +#9649=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_42','Imported topsoils',#9643,$,$); +#9650=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_43','Inorganic fertilizers',#9643,$,$); +#9651=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_50','Manufactured growing mediums',#9643,$,$); +#9652=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_51','Manufactured topsoils',#9643,$,$); +#9653=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_52','Manures',#9643,$,$); +#9654=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_55','Mycorrhizal inoculants',#9643,$,$); +#9655=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_57','Non-compost turf dressings',#9643,$,$); +#9656=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_58','Organic fertilizers',#9643,$,$); +#9657=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_75','Sanitized and stabilized composts',#9643,$,$); +#9658=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_80','Soil amelioration aggregates',#9643,$,$); +#9659=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_81','Soil amelioration industrial by-products',#9643,$,$); +#9660=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_82','Soil amelioration minerals',#9643,$,$); +#9661=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_83','Soil conditioning agents',#9643,$,$); +#9662=IFCCLASSIFICATIONREFERENCE($,'Pr_45_31_89_84','Soil moisture retention additives',#9643,$,$); +#9663=IFCCLASSIFICATIONREFERENCE($,'Pr_45_57','Non-rigid sheet, mat and strip flora and fauna products',#9529,$,$); +#9664=IFCCLASSIFICATIONREFERENCE($,'Pr_45_57_91','Turf and pre-planted substrates',#9663,$,$); +#9665=IFCCLASSIFICATIONREFERENCE($,'Pr_45_57_91_20','Cultivated turf',#9664,$,$); +#9666=IFCCLASSIFICATIONREFERENCE($,'Pr_45_57_91_56','Natural turf',#9664,$,$); +#9667=IFCCLASSIFICATIONREFERENCE($,'Pr_45_57_91_63','Pre-planted coir rolls',#9664,$,$); +#9668=IFCCLASSIFICATIONREFERENCE($,'Pr_45_57_91_64','Pre-planted pallets',#9664,$,$); +#9669=IFCCLASSIFICATIONREFERENCE($,'Pr_45_57_91_65','Pre-planted vegetation mats',#9664,$,$); +#9670=IFCCLASSIFICATIONREFERENCE($,'Pr_45_57_91_67','Pre-seeded mats',#9664,$,$); +#9671=IFCCLASSIFICATIONREFERENCE($,'Pr_45_57_91_76','Seeded area turf edging',#9664,$,$); +#9672=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63','Plant support products',#9529,$,$); +#9673=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63','Plant containers',#9672,$,$); +#9674=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_02','Aluminium divided modular units',#9673,$,$); +#9675=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_03','Aluminium edge retaining profiles',#9673,$,$); +#9676=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_04','Aluminium plant containers',#9673,$,$); +#9677=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_05','Aquatic plant containers',#9673,$,$); +#9678=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_07','Biodegradable plant containers',#9673,$,$); +#9679=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_11','Cast and wrought iron plant containers',#9673,$,$); +#9680=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_15','Concrete and reconstituted aggregate plant containers',#9673,$,$); +#9681=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_17','Cropping bags',#9673,$,$); +#9682=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_22','Divided modular planting units',#9673,$,$); +#9683=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_29','Flower pouches',#9673,$,$); +#9684=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_34','Glass-reinforced plastic (GRP) and advanced composite (AC) plant containers',#9673,$,$); +#9685=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_36','Hanging plant containers',#9673,$,$); +#9686=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_37','Herb planters',#9673,$,$); +#9687=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_38','Herb wheels',#9673,$,$); +#9688=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_56','Natural planting cassettes',#9673,$,$); +#9689=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_62','Plastics divided modular units',#9673,$,$); +#9690=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_64','Polymer plant containers',#9673,$,$); +#9691=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_65','Potato planters',#9673,$,$); +#9692=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_72','Round plant containers',#9673,$,$); +#9693=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_80','Square plant containers',#9673,$,$); +#9694=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_81','Stainless steel divided modular units',#9673,$,$); +#9695=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_82','Stainless steel edge retaining profiles',#9673,$,$); +#9696=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_83','Stainless steel plant containers',#9673,$,$); +#9697=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_84','Steel plant containers',#9673,$,$); +#9698=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_85','Stone plant containers',#9673,$,$); +#9699=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_86','Strawberry planters',#9673,$,$); +#9700=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_87','Terracotta plant containers',#9673,$,$); +#9701=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_88','Terrariums',#9673,$,$); +#9702=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_89','Treated timber plant containers',#9673,$,$); +#9703=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_90','Trough plant containers',#9673,$,$); +#9704=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_92','Untreated timber plant containers',#9673,$,$); +#9705=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_94','Vases',#9673,$,$); +#9706=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_96','Wall planters',#9673,$,$); +#9707=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_63_97','Window boxes',#9673,$,$); +#9708=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64','Plant support and protection',#9672,$,$); +#9709=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_11','Canes',#9708,$,$); +#9710=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_14','Climbing plant supports',#9708,$,$); +#9711=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_15','Concrete tree surrounds',#9708,$,$); +#9712=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_30','Floral foam fixing mediums',#9708,$,$); +#9713=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_33','Geocellular modular plastics structured soil units',#9708,$,$); +#9714=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_35','Guy wire kits',#9708,$,$); +#9715=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_63','Plastics mesh reinforcement',#9708,$,$); +#9716=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_66','Polystyrene (PS) fixing mediums',#9708,$,$); +#9717=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_67','Protective fencing',#9708,$,$); +#9718=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_72','Rootball securing frames',#9708,$,$); +#9719=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_78','Shrub protectors',#9708,$,$); +#9720=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_80','Softwood pegs',#9708,$,$); +#9721=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_83','Stake ties',#9708,$,$); +#9722=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_84','Stakes',#9708,$,$); +#9723=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_86','Tensioned wire trellises',#9708,$,$); +#9724=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_87','Tree grilles',#9708,$,$); +#9725=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_88','Tree guards',#9708,$,$); +#9726=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_89','Tree protectors',#9708,$,$); +#9727=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_90','Trellises',#9708,$,$); +#9728=IFCCLASSIFICATIONREFERENCE($,'Pr_45_63_64_96','Weed control mats',#9708,$,$); +#9729=IFCCLASSIFICATIONREFERENCE($,'Pr_50','Fabric accessory products',#4923,$,$); +#9730=IFCCLASSIFICATIONREFERENCE($,'Pr_60','Services source products',#4923,$,$); +#9731=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45','Water filtration and treatment products',#9730,$,$); +#9732=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_01','Aerator products',#9731,$,$); +#9733=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_01_11','Cascade trays',#9732,$,$); +#9734=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_01_30','Fine bubble diffuser manifolds',#9732,$,$); +#9735=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_01_37','High speed vertical shaft surface aerators',#9732,$,$); +#9736=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_01_38','Horizontal shaft surface aerators',#9732,$,$); +#9737=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_01_44','Jet aeration manifolds',#9732,$,$); +#9738=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_01_48','Low speed vertical shaft surface aerators',#9732,$,$); +#9739=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_01_96','Wind powered aerators',#9732,$,$); +#9740=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_03','Air blower products',#9731,$,$); +#9741=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_03_12','Centrifugal blowers',#9740,$,$); +#9742=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_03_55','Multicore blowers',#9740,$,$); +#9743=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_03_72','Rotary lobe air blowers',#9740,$,$); +#9744=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_03_73','Rotary screw blowers',#9740,$,$); +#9745=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_03_78','Side channel blowers',#9740,$,$); +#9746=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_03_90','Turbo blowers',#9740,$,$); +#9747=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_07','Biological filtration wastewater treatment products',#9731,$,$); +#9748=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_07_21','De Hoxar separators',#9747,$,$); +#9749=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_07_22','Dissolved air flotation plants',#9747,$,$); +#9750=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_07_23','Disc biological filters',#9747,$,$); +#9751=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_07_25','Drum filters',#9747,$,$); +#9752=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_07_46','Lamella plate packs',#9747,$,$); +#9753=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_07_51','Membrane bio-reactors',#9747,$,$); +#9754=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_07_60','Packaged lamella units',#9747,$,$); +#9755=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_07_72','Rotating biological contactors',#9747,$,$); +#9756=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_12','Centrifuge products',#9731,$,$); +#9757=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_22','Decanters',#9731,$,$); +#9758=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_22_30','Floating decanters',#9757,$,$); +#9759=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_22_52','Motor driven moving arm decanters',#9757,$,$); +#9760=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_24','Distributor products',#9731,$,$); +#9761=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_24_52','Motorized trickling filter distributor arms',#9760,$,$); +#9762=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_24_60','Paddlewheel trickling filter distributor arms',#9760,$,$); +#9763=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_24_72','Rotary reaction trickling filter distributor arms and syphons',#9760,$,$); +#9764=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_24_90','Turbine trickling filter distributor arms',#9760,$,$); +#9765=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_29','Filtration mediums',#9731,$,$); +#9766=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_29_14','Clay trickling filter floor tiles',#9765,$,$); +#9767=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_29_16','Concrete trickling filter floor tiles',#9765,$,$); +#9768=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_29_65','Plastics structured cross-flow mediums',#9765,$,$); +#9769=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_29_70','Random packed plastics mediums',#9765,$,$); +#9770=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_30','Flow control products',#9731,$,$); +#9771=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_30_15','Composite plastics penstocks',#9770,$,$); +#9772=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_30_23','Diffuser drums',#9770,$,$); +#9773=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_30_31','Float activated flow control units',#9770,$,$); +#9774=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_30_52','Metal penstocks',#9770,$,$); +#9775=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_30_83','Stop gates',#9770,$,$); +#9776=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_30_84','Stop logs',#9770,$,$); +#9777=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_30_93','Vortex water flow controls',#9770,$,$); +#9778=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_30_95','Water baffles',#9770,$,$); +#9779=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_30_96','Weir gates',#9770,$,$); +#9780=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_30_97','Weir plates',#9770,$,$); +#9781=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_33','Grit trap products',#9731,$,$); +#9782=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_33_17','Cross-flow separators',#9781,$,$); +#9783=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_33_57','Non-powered vortex separators',#9781,$,$); +#9784=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_33_65','Powered vortex flow separators',#9781,$,$); +#9785=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_34','Grit classifier products',#9731,$,$); +#9786=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_34_15','Classifier vortex washer and de-waterers',#9785,$,$); +#9787=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_34_71','Reciprocating rake classifiers',#9785,$,$); +#9788=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_34_76','Screw classifiers',#9785,$,$); +#9789=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_46','Launder trough products',#9731,$,$); +#9790=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_46_46','Launder troughs',#9789,$,$); +#9791=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_58','Odour control tank cover products',#9731,$,$); +#9792=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_58_33','Gas containment covers',#9791,$,$); +#9793=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_58_58','Odour control covers',#9791,$,$); +#9794=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_74','Scum removal products',#9731,$,$); +#9795=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_74_30','Fixed scum pipes',#9794,$,$); +#9796=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_74_72','Rotating scum pipes',#9794,$,$); +#9797=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_74_75','Scum beaches',#9794,$,$); +#9798=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_74_76','Scum removal boards',#9794,$,$); +#9799=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_74_77','Scum removal valves',#9794,$,$); +#9800=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_74_85','Surface scum scrapers',#9794,$,$); +#9801=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_76','Sludge de-watering products',#9731,$,$); +#9802=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_76_07','Belt presses',#9801,$,$); +#9803=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_76_22','Decanter centrifuges',#9801,$,$); +#9804=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_76_65','Plate presses',#9801,$,$); +#9805=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_78','Sludge removal products',#9731,$,$); +#9806=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_78_08','Bottom sludge scrapers',#9805,$,$); +#9807=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_78_12','Chain and flight scrapers',#9805,$,$); +#9808=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_78_72','Rotating full bridge scrapers',#9805,$,$); +#9809=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_78_73','Rotating half bridge scrapers',#9805,$,$); +#9810=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_78_78','Siphons',#9805,$,$); +#9811=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_79','Sludge screening products',#9731,$,$); +#9812=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_79_34','Gravity sludge screens',#9811,$,$); +#9813=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_79_65','Pressurized sludge screens',#9811,$,$); +#9814=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_80','Sludge thickening products',#9731,$,$); +#9815=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_80_24','Drum thickeners',#9814,$,$); +#9816=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_80_34','Gravity belt thickeners',#9814,$,$); +#9817=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_80_63','Picket fence thickeners',#9814,$,$); +#9818=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_85','Suspended growth and tertiary wastewater treatment products',#9731,$,$); +#9819=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_90','Wastewater and water mixer products',#9731,$,$); +#9820=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_90_15','Channel mixers',#9819,$,$); +#9821=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_90_51','Mechanical mixers',#9819,$,$); +#9822=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_90_85','Static pipe mixers',#9819,$,$); +#9823=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_90_86','Submersible propeller mixers',#9819,$,$); +#9824=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_93','Wastewater screenings treatment products',#9731,$,$); +#9825=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_93_42','Impeller and compactor tank wash',#9824,$,$); +#9826=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_93_50','Macerator and de-waterer tank wash',#9824,$,$); +#9827=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_93_75','Screw compactors',#9824,$,$); +#9828=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_93_96','Washer compactors',#9824,$,$); +#9829=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94','Wastewater screening and water abstraction products',#9731,$,$); +#9830=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_06','Band screens',#9829,$,$); +#9831=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_08','Brushed and macerator combined screens',#9829,$,$); +#9832=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_09','Brushed screens',#9829,$,$); +#9833=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_15','Coanda screens',#9829,$,$); +#9834=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_23','Disc screens',#9829,$,$); +#9835=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_25','Drum screens',#9829,$,$); +#9836=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_29','Finescreens',#9829,$,$); +#9837=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_30','Flushing screens',#9829,$,$); +#9838=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_34','Grab screens',#9829,$,$); +#9839=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_70','Raked bar screens',#9829,$,$); +#9840=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_72','Rotary drum screens',#9829,$,$); +#9841=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_73','Rotating bar interceptors',#9829,$,$); +#9842=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_78','Slot screens',#9829,$,$); +#9843=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_80','Spiral and compaction combined screens',#9829,$,$); +#9844=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_81','Spiral screens',#9829,$,$); +#9845=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_83','Static perforated plate screens',#9829,$,$); +#9846=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_84','Static wedge wire screens',#9829,$,$); +#9847=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_94_85','Step screens',#9829,$,$); +#9848=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_95','Wastewater settlement products',#9731,$,$); +#9849=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_95_15','Conical glass reinforced plastics (GRP) settlement tanks',#9848,$,$); +#9850=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_96','Wastewater tank flushing products',#9731,$,$); +#9851=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_96_14','Circular tank flushing vessels',#9850,$,$); +#9852=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_96_30','Flushing gates',#9850,$,$); +#9853=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_96_89','Tipping troughs',#9850,$,$); +#9854=IFCCLASSIFICATIONREFERENCE($,'Pr_60_45_96_94','Vacuum operated storage reservoirs',#9850,$,$); +#9855=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50','Tank, cylinder and vessel products',#9730,$,$); +#9856=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_10','Bulk storage tanks',#9855,$,$); +#9857=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_10_34','Glass fused steel tanks',#9856,$,$); +#9858=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_10_64','Plastics tanks',#9856,$,$); +#9859=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_10_66','Precast concrete modular tanks',#9856,$,$); +#9860=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_20','Cylinders and buffer vessels',#9855,$,$); +#9861=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_20_02','Accumulators',#9860,$,$); +#9862=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_20_10','Buffer vessels',#9860,$,$); +#9863=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_20_21','Direct hot water storage cylinders',#9860,$,$); +#9864=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_20_22','Direct insulated hot water combination units',#9860,$,$); +#9865=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_20_23','Double feed indirect hot water storage cylinders',#9860,$,$); +#9866=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_20_24','Double feed indirect insulated hot water combination units',#9860,$,$); +#9867=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_20_25','Dual coil hot water storage cylinders',#9860,$,$); +#9868=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_20_28','Expansion vessels',#9860,$,$); +#9869=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_20_42','Indirectly heated unvented hot water storage cylinders',#9860,$,$); +#9870=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_20_77','Single feed indirect insulated combination units',#9860,$,$); +#9871=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_20_78','Single feed indirect hot water storage cylinders',#9860,$,$); +#9872=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_33','Gas storage cylinders',#9855,$,$); +#9873=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_33_14','Compressed air cylinders',#9872,$,$); +#9874=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_33_15','Compressed gas cylinders',#9872,$,$); +#9875=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_33_37','High pressure fire extinguishing gas storage cylinders',#9872,$,$); +#9876=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_33_46','Liquefied gas cylinders',#9872,$,$); +#9877=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_33_47','Liquid oxygen cylinders',#9872,$,$); +#9878=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_33_48','Low pressure fire extinguishing gas storage cylinders',#9872,$,$); +#9879=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_33_51','Medical compressed gas cylinders',#9872,$,$); +#9880=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_41','Irrigation and water feature reservoirs',#9855,$,$); +#9881=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_41_41','Integral water features',#9880,$,$); +#9882=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_41_53','Modular irrigation reservoirs',#9880,$,$); +#9883=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_41_65','Pre-formed reservoirs',#9880,$,$); +#9884=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_41_66','Pre-formed rigid pond liners',#9880,$,$); +#9885=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_41_77','Sealed irrigation reservoirs',#9880,$,$); +#9886=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_41_96','Water feature containers',#9880,$,$); +#9887=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_46','Liquid fuel tank accessories',#9855,$,$); +#9888=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_46_45','Liquid fuel tank contents gauges',#9887,$,$); +#9889=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_46_46','Liquid fuel tank drip trays',#9887,$,$); +#9890=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_46_47','Liquid fuel tank fill points',#9887,$,$); +#9891=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_46_48','Liquid fuel tank outflow heaters',#9887,$,$); +#9892=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_46_49','Liquid fuel tank heaters',#9887,$,$); +#9893=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_46_59','Overflow prevention devices',#9887,$,$); +#9894=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_46_87','Tank access chambers',#9887,$,$); +#9895=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_47','Liquid fuel tanks',#9855,$,$); +#9896=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_47_11','Liquid fuel service tanks',#9895,$,$); +#9897=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_47_12','Carbon steel liquid fuel tanks',#9895,$,$); +#9898=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_47_13','Carbon steel oil tanks',#9895,$,$); +#9899=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_47_34','Glass reinforced plastics liquid fuel tanks',#9895,$,$); +#9900=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_47_63','Plastics oil tanks',#9895,$,$); +#9901=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_47_84','Stainless steel liquid fuel tanks',#9895,$,$); +#9902=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_67','Pressure storage vessels',#9855,$,$); +#9903=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_67_31','Foam fire fighting tanks',#9902,$,$); +#9904=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_67_48','Liquefied petroleum gas (LPG) storage vessels',#9902,$,$); +#9905=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_67_52','Metal liquid or gas pressure vessels',#9902,$,$); +#9906=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_67_70','Refrigerant recovery storage vessels',#9902,$,$); +#9907=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_67_93','Vacuum flasks',#9902,$,$); +#9908=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_67_94','Vacuum insulated evaporator (VIE) storage vessels',#9902,$,$); +#9909=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_85','Storage of solid materials',#9855,$,$); +#9910=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_85_01','Above ground storage containers for solid fuel',#9909,$,$); +#9911=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_85_07','Below ground storage containers for solid fuel',#9909,$,$); +#9912=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_85_78','Silos',#9909,$,$); +#9913=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96','Water tanks and cisterns',#9855,$,$); +#9914=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_15','Concrete tanks',#9913,$,$); +#9915=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_20','Cylindrical tanks',#9913,$,$); +#9916=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_32','Galvanized steel cisterns',#9913,$,$); +#9917=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_33','Galvanized steel tanks',#9913,$,$); +#9918=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_34','Glass reinforced plastics cisterns',#9913,$,$); +#9919=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_35','Glass reinforced pressure tanks',#9913,$,$); +#9920=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_36','Glass reinforced plastics tanks',#9913,$,$); +#9921=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_52','Moulded plastics tanks',#9913,$,$); +#9922=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_53','Moulded plastics cisterns',#9913,$,$); +#9923=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_62','Piped attenuation structures',#9913,$,$); +#9924=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_63','Plastics bladder water storage tanks',#9913,$,$); +#9925=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_64','Polyethylene (PE) tanks',#9913,$,$); +#9926=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_65','Polypropylene (PP) tanks',#9913,$,$); +#9927=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_70','Rainwater storage butts',#9913,$,$); +#9928=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_76','Sectional carbon steel tanks',#9913,$,$); +#9929=IFCCLASSIFICATIONREFERENCE($,'Pr_60_50_96_84','Stainless steel tanks',#9913,$,$); +#9930=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55','Liquid and gas source products',#9730,$,$); +#9931=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_31','Inlet connections and fill connections',#9930,$,$); +#9932=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_31_29','Foam inlet adaptors',#9931,$,$); +#9933=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_31_30','Foam inlet boxes',#9931,$,$); +#9934=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_31_42','Riser inlet breechings and boxes',#9931,$,$); +#9935=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_31_47','Liquefied petroleum gas (LPG) fill connections',#9931,$,$); +#9936=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_31_96','Water inlet adaptors',#9931,$,$); +#9937=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_31_97','Water inlet boxes',#9931,$,$); +#9938=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_33','Gas and vacuum generators',#9930,$,$); +#9939=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_33_04','Anaerobic digesters',#9938,$,$); +#9940=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_33_13','Chlorine generators',#9938,$,$); +#9941=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_33_39','Hydrogen generators',#9938,$,$); +#9942=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_33_56','Nitrogen generators',#9938,$,$); +#9943=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_33_73','Pressure swing adsorption (PSA) plant',#9938,$,$); +#9944=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_33_94','Vacuum plant',#9938,$,$); +#9945=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96','Water treatment chemicals',#9930,$,$); +#9946=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_06','Bacteria and biofouling inhibitors',#9945,$,$); +#9947=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_07','Biocide chemicals',#9945,$,$); +#9948=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_08','Biodispersant chemicals',#9945,$,$); +#9949=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_12','Chlorination chemicals',#9945,$,$); +#9950=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_15','Corrosion inhibitor chemicals',#9945,$,$); +#9951=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_16','Corrosion inhibitor chemicals for closed circuits',#9945,$,$); +#9952=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_21','De-chlorination chemicals',#9945,$,$); +#9953=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_22','Dispersant chemicals',#9945,$,$); +#9954=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_58','Odour control chemicals',#9945,$,$); +#9955=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_64','pH correction chemicals',#9945,$,$); +#9956=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_77','Scale inhibitor chemicals',#9945,$,$); +#9957=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_78','Septicity control chemicals',#9945,$,$); +#9958=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_79','Settlement coagulants',#9945,$,$); +#9959=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_96_96','Water plumbosolvency reduction chemicals',#9945,$,$); +#9960=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97','Water treatment products',#9930,$,$); +#9961=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_02','Alkalinity dosing units',#9960,$,$); +#9962=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_06','Bioaugmentation devices',#9960,$,$); +#9963=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_07','Biocide dosing pots',#9960,$,$); +#9964=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_11','Chemical disinfection devices',#9960,$,$); +#9965=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_12','Chemical dosing pots',#9960,$,$); +#9966=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_13','Chemical injectors',#9960,$,$); +#9967=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_14','Clarifiers',#9960,$,$); +#9968=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_15','Coagulant dosing units',#9960,$,$); +#9969=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_20','Deionization units',#9960,$,$); +#9970=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_21','Desalination units',#9960,$,$); +#9971=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_22','Disinfectant dosing units',#9960,$,$); +#9972=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_23','Distillation units',#9960,$,$); +#9973=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_24','Drinking water nitrate removal devices',#9960,$,$); +#9974=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_27','Electrodialysis units',#9960,$,$); +#9975=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_41','Inline filter units',#9960,$,$); +#9976=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_43','Ion exchange demineralization units',#9960,$,$); +#9977=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_44','Ion exchange softening units',#9960,$,$); +#9978=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_50','Magnetic water conditioners',#9960,$,$); +#9979=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_63','pH control dosing units',#9960,$,$); +#9980=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_72','Reverse osmosis units',#9960,$,$); +#9981=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_85','Sterilizers',#9960,$,$); +#9982=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_86','Surface skimmers',#9960,$,$); +#9983=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_93','Ultraviolet (UV) disinfection devices',#9960,$,$); +#9984=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_95','Water aerators',#9960,$,$); +#9985=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_96','Water conditioners',#9960,$,$); +#9986=IFCCLASSIFICATIONREFERENCE($,'Pr_60_55_97_97','Water treatment dosing pots',#9960,$,$); +#9987=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60','Heating and cooling source products',#9730,$,$); +#9988=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08','Boilers',#9987,$,$); +#9989=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_08','Biomass boilers',#9988,$,$); +#9990=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_24','Dual fuel cast iron boilers',#9988,$,$); +#9991=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_25','Dual fuel steel shell boilers',#9988,$,$); +#9992=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_27','Electric boilers',#9988,$,$); +#9993=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_33','Gas fired boilers',#9988,$,$); +#9994=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_34','Gas fired condensing boilers',#9988,$,$); +#9995=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_35','Gas fired cast iron boilers',#9988,$,$); +#9996=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_36','Gas fired steel shell boilers',#9988,$,$); +#9997=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_37','Gas fired water tube boilers',#9988,$,$); +#9998=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_56','Oil fired condensing boilers',#9988,$,$); +#9999=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_57','Oil fired non-condensing boilers',#9988,$,$); +#10000=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_58','Oil fired cast iron boilers',#9988,$,$); +#10001=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_59','Oil fired steel shell boilers',#9988,$,$); +#10002=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_60','Oil fired water tube boilers',#9988,$,$); +#10003=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_80','Solid fuel cast iron boilers',#9988,$,$); +#10004=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_81','Solid fuel steel shell boilers',#9988,$,$); +#10005=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_83','Submerged panel heat exchangers',#9988,$,$); +#10006=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_08_84','Submerged pipe heat exchangers',#9988,$,$); +#10007=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_10','Burners',#9987,$,$); +#10008=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_10_03','Atmospheric gas burners',#10007,$,$); +#10009=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_10_05','Atomizing oil burners',#10007,$,$); +#10010=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_10_29','Forced draught dual fuel burners',#10007,$,$); +#10011=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_10_30','Forced draught gas burners',#10007,$,$); +#10012=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_10_31','Forced draught oil burners',#10007,$,$); +#10013=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_10_65','Pre-mix gas burners',#10007,$,$); +#10014=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_13','Chillers and cooling towers',#9987,$,$); +#10015=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_13_01','Adsorption chillers',#10014,$,$); +#10016=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_13_02','Adiabatic chillers',#10014,$,$); +#10017=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_13_04','Air cooled liquid chillers',#10014,$,$); +#10018=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_13_14','Closed circuit cooling towers',#10014,$,$); +#10019=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_13_22','Direct fired absorption liquid chillers',#10014,$,$); +#10020=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_13_27','Electric driven refrigerant compressors',#10014,$,$); +#10021=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_13_33','Gas engine driven refrigerant compressors',#10014,$,$); +#10022=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_13_38','Hot water fired absorption liquid chillers',#10014,$,$); +#10023=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_13_59','Open circuit cooling towers',#10014,$,$); +#10024=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_13_84','Steam fired absorption liquid chillers',#10014,$,$); +#10025=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_13_96','Water cooled liquid chillers',#10014,$,$); +#10026=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_36','Heat recovery distribution equipment',#9987,$,$); +#10027=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_36_26','Economizers',#10026,$,$); +#10028=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_36_36','Heat pipes',#10026,$,$); +#10029=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_36_60','Passive heat exchangers',#10026,$,$); +#10030=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_36_62','Plate recuperators',#10026,$,$); +#10031=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_36_72','Regenerators',#10026,$,$); +#10032=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_36_74','Run-around coils',#10026,$,$); +#10033=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_36_88','Thermal wheels',#10026,$,$); +#10034=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_38','Calorifiers and plate heat exchangers',#9987,$,$); +#10035=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_38_36','Heat interface units',#10034,$,$); +#10036=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_38_38','Hot water non-storage calorifiers',#10034,$,$); +#10037=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_38_42','Instantaneous plate heat exchangers',#10034,$,$); +#10038=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_38_62','Plate heat exchangers',#10034,$,$); +#10039=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_38_84','Steam to water non-storage calorifiers',#10034,$,$); +#10040=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_38_85','Storage calorifiers',#10034,$,$); +#10041=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_81','Solar heat collectors',#9987,$,$); +#10042=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_81_26','Evacuated tube solar collectors',#10041,$,$); +#10043=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_81_30','Flat plate solar collectors',#10041,$,$); +#10044=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_81_80','Solar heat stores',#10041,$,$); +#10045=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_81_81','Solar trackers',#10041,$,$); +#10046=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_83','Solid fuel and waste handling equipment',#9987,$,$); +#10047=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_83_05','Ash handling equipment',#10046,$,$); +#10048=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_83_81','Solid fuel handling equipment',#10046,$,$); +#10049=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_84','Steam generators',#9987,$,$); +#10050=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_84_14','Clean steam generators',#10049,$,$); +#10051=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_96','Water heaters',#9987,$,$); +#10052=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_96_26','Electric instantaneous shower units',#10051,$,$); +#10053=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_96_27','Electric instantaneous water heaters',#10051,$,$); +#10054=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_96_28','Electric storage water heaters',#10051,$,$); +#10055=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_96_31','Gas-fired condensing water heaters',#10051,$,$); +#10056=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_96_33','Gas-fired instantaneous water heaters',#10051,$,$); +#10057=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_96_34','Gas-fired storage water heaters',#10051,$,$); +#10058=IFCCLASSIFICATIONREFERENCE($,'Pr_60_60_96_42','Immersion heaters',#10051,$,$); +#10059=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65','Air and fume source products',#9730,$,$); +#10060=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_03','Air handling units',#10059,$,$); +#10061=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_03_28','Extract and return air handling units',#10060,$,$); +#10062=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_03_86','Supply air handling units',#10060,$,$); +#10063=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_03_87','Supply and return air handling units',#10060,$,$); +#10064=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_31','Fume cupboards and safety cabinets',#10059,$,$); +#10065=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_31_33','General-purpose fume cupboards',#10064,$,$); +#10066=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_31_46','Laminar flow cabinets',#10064,$,$); +#10067=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_31_52','Microbiological safety cabinets',#10064,$,$); +#10068=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_31_71','Recirculatory filtration fume cupboards',#10064,$,$); +#10069=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_31_76','School fume cupboards',#10064,$,$); +#10070=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_31_94','Variable air volume fume cupboards',#10064,$,$); +#10071=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_37','Heating and cooling coils',#10059,$,$); +#10072=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_37_12','Chilled water cooling coils',#10071,$,$); +#10073=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_37_27','Electric heater batteries',#10071,$,$); +#10074=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_37_33','Gas fired heater batteries',#10071,$,$); +#10075=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_37_41','Intercoolers',#10071,$,$); +#10076=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_37_47','Low temperature hot water heating coils',#10071,$,$); +#10077=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_37_72','Refrigerant cooling coils',#10071,$,$); +#10078=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_94','Ventilation hoods and extract points',#10059,$,$); +#10079=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_94_29','Fume capturing hoods',#10078,$,$); +#10080=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_94_30','Fume enclosing hoods',#10078,$,$); +#10081=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_94_31','Fume receiving hoods',#10078,$,$); +#10082=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_94_32','Fume extract points',#10078,$,$); +#10083=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_94_45','Kitchen canopies',#10078,$,$); +#10084=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_94_46','Kitchen extractor hoods',#10078,$,$); +#10085=IFCCLASSIFICATIONREFERENCE($,'Pr_60_65_94_94','Vehicle exhaust nozzles',#10078,$,$); +#10086=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70','Power supply products',#9730,$,$); +#10087=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_06','Batteries and chargers',#10086,$,$); +#10088=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_06_05','Automatic battery chargers',#10087,$,$); +#10089=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_06_06','Backup battery supply',#10087,$,$); +#10090=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_06_12','Central battery supply units',#10087,$,$); +#10091=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_06_23','Direct current battery charge controllers',#10087,$,$); +#10092=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_06_27','Electric vehicle chargers',#10087,$,$); +#10093=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_06_67','PV generator junction boxes',#10087,$,$); +#10094=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_06_71','Rechargeable dry cell battery chargers',#10087,$,$); +#10095=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_06_76','Sealed lead acid batteries',#10087,$,$); +#10096=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_06_77','Sealed nickel cadmium batteries',#10087,$,$); +#10097=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_06_94','Valve regulated (sealed) lead acid',#10087,$,$); +#10098=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_06_95','Vented lead acid batteries',#10087,$,$); +#10099=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_06_96','Vented nickel cadmium batteries',#10087,$,$); +#10100=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_22','Distribution boxes and switchboards',#10086,$,$); +#10101=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_22_11','Cable distribution cabinets',#10100,$,$); +#10102=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_22_15','Consumer units',#10100,$,$); +#10103=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_22_19','Cubicle switchboards',#10100,$,$); +#10104=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_22_22','Distribution boards',#10100,$,$); +#10105=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_22_28','Extension boxes',#10100,$,$); +#10106=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_22_46','Lighting distribution boxes',#10100,$,$); +#10107=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_22_50','Master distribution boxes',#10100,$,$); +#10108=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_22_79','Slave distribution boxes',#10100,$,$); +#10109=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_22_80','Spreader boxes',#10100,$,$); +#10110=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_22_85','Sub-main distribution boards',#10100,$,$); +#10111=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_28','Extra high voltage switchgear',#10086,$,$); +#10112=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36','High voltage switchgear and transformers',#10086,$,$); +#10113=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_06','High voltage busbar metering panels',#10112,$,$); +#10114=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_07','High voltage bus-section panels',#10112,$,$); +#10115=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_12','High voltage circuit breakers',#10112,$,$); +#10116=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_18','High voltage current transformers',#10112,$,$); +#10117=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_22','High voltage disconnectors',#10112,$,$); +#10118=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_24','High voltage dry type transformers',#10112,$,$); +#10119=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_26','High voltage earthing switches',#10112,$,$); +#10120=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_30','High voltage liquid immersed transformers',#10112,$,$); +#10121=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_37','High voltage fuses',#10112,$,$); +#10122=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_53','High voltage modular switchboards',#10112,$,$); +#10123=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_70','High voltage rectiformers',#10112,$,$); +#10124=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_72','High voltage ring main units',#10112,$,$); +#10125=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_75','High voltage safety matting',#10112,$,$); +#10126=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_80','High voltage switch-disconnectors',#10112,$,$); +#10127=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_81','High voltage switch-fuse combinations',#10112,$,$); +#10128=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_82','High voltage switches',#10112,$,$); +#10129=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_83','High voltage switchgear protection and control modules',#10112,$,$); +#10130=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_36_94','High voltage vacuum circuit breaker panels',#10112,$,$); +#10131=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48','Low voltage switchgear',#10086,$,$); +#10132=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_05','Automatic transfer switching equipment (TSE)',#10131,$,$); +#10133=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_06','Busbar chambers',#10131,$,$); +#10134=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_07','Busbar trunking feed units',#10131,$,$); +#10135=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_08','Busbar trunking fire barrier units',#10131,$,$); +#10136=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_09','Busbar trunking tap-off units',#10131,$,$); +#10137=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_11','Changeover switches',#10131,$,$); +#10138=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_27','Electrical cut-outs',#10131,$,$); +#10139=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_30','Fireman\X2\2019\X0\s emergency switches',#10131,$,$); +#10140=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_44','Low voltage fuse-switch disconnectors',#10131,$,$); +#10141=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_45','Low voltage safety matting',#10131,$,$); +#10142=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_46','Low voltage switch-disconnector fuses',#10131,$,$); +#10143=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_47','Low voltage switch disconnectors',#10131,$,$); +#10144=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_48','Low voltage switches',#10131,$,$); +#10145=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_49','Low voltage switchgear tripping units',#10131,$,$); +#10146=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_62','Photovoltaic array junction boxes',#10131,$,$); +#10147=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_63','Photovoltaic generator junction boxes',#10131,$,$); +#10148=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_48_66','Power busbar trunking',#10131,$,$); +#10149=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_64','Power conditioning supply equipment',#10086,$,$); +#10150=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_64_86','Static inverter power supply units',#10149,$,$); +#10151=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_64_93','Uninterruptible power supply (UPS) units',#10149,$,$); +#10152=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_64_94','Uninterruptible power supply (UPS) remote alarm panels',#10149,$,$); +#10153=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65','Power generators, engines and packaged combined heat and power (CHP) units',#10086,$,$); +#10154=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_03','Alternators',#10153,$,$); +#10155=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_05','Automatic voltage regulators',#10153,$,$); +#10156=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_32','Gas turbines (CCGT)',#10153,$,$); +#10157=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_33','Generator control panels',#10153,$,$); +#10158=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_34','Generator sets',#10153,$,$); +#10159=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_35','Governors',#10153,$,$); +#10160=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_37','Horizontal axis wind turbines (HAWT)',#10153,$,$); +#10161=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_38','Hydraulic power units',#10153,$,$); +#10162=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_39','Hydro turbines',#10153,$,$); +#10163=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_41','Internal combustion engines',#10153,$,$); +#10164=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_47','Load banks',#10153,$,$); +#10165=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_58','Offshore wind turbines',#10153,$,$); +#10166=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_59','Onshore wind turbines',#10153,$,$); +#10167=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_60','Packaged combined heat and power (CHP) units',#10153,$,$); +#10168=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_63','Photovoltaic modules',#10153,$,$); +#10169=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_94','Vertical axis wind turbines (VAWT)',#10153,$,$); +#10170=IFCCLASSIFICATIONREFERENCE($,'Pr_60_70_65_97','Wind turbine controllers',#10153,$,$); +#10171=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75','Communications source products',#9730,$,$); +#10172=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_01','Antennas and satellite dishes',#10171,$,$); +#10173=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_01_22','Digital audio broadcasting (DAB) antennas',#10172,$,$); +#10174=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_01_31','Frequency modulation (FM) antennas',#10172,$,$); +#10175=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_01_75','Satellite dishes',#10172,$,$); +#10176=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_01_92','Ultra-high frequency (UHF) antennas',#10172,$,$); +#10177=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_03','Audio and video players and recorders',#10171,$,$); +#10178=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_03_07','Blu-ray players',#10177,$,$); +#10179=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_03_11','Cassette players',#10177,$,$); +#10180=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_03_15','Compact disc players',#10177,$,$); +#10181=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_03_22','Digital video recorders',#10177,$,$); +#10182=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_03_56','Network video recorders',#10177,$,$); +#10183=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_03_70','Radio tuners',#10177,$,$); +#10184=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_03_87','Time lapse video recorders',#10177,$,$); +#10185=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_06','Audio input devices',#10171,$,$); +#10186=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_06_53','Microphones',#10185,$,$); +#10187=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_06_60','Paging consoles',#10185,$,$); +#10188=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08','Audio and visual source products',#10171,$,$); +#10189=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_01','Artificial reverberation, time delay and frequency shift equipment',#10188,$,$); +#10190=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_02','Audio amplifiers',#10188,$,$); +#10191=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_03','Audio equalizers',#10188,$,$); +#10192=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_04','Automatic announcement equipment',#10188,$,$); +#10193=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_05','Auxiliary passive elements',#10188,$,$); +#10194=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_21','Digital broadcast signal router multiswitches',#10188,$,$); +#10195=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_23','Diplexers',#10188,$,$); +#10196=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_28','External source input points',#10188,$,$); +#10197=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_46','Launch amplifiers',#10188,$,$); +#10198=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_48','Local volume controls',#10188,$,$); +#10199=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_50','Masthead amplifiers',#10188,$,$); +#10200=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_52','Mixer amplifiers',#10188,$,$); +#10201=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_54','Mixers',#10188,$,$); +#10202=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_55','Multiswitches',#10188,$,$); +#10203=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_63','Pre-amplifiers',#10188,$,$); +#10204=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_71','Remote microphone input points',#10188,$,$); +#10205=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_08_78','Splitters',#10188,$,$); +#10206=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_78','Signal transmitters',#10171,$,$); +#10207=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_78_85','Supervised premises transceivers',#10206,$,$); +#10208=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_78_91','Television equalizers',#10206,$,$); +#10209=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86','Surveillance cameras, monitors and ancillaries',#10171,$,$); +#10210=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_01','Automatic number plate recognition cameras',#10209,$,$); +#10211=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_02','Analogue box cameras',#10209,$,$); +#10212=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_03','Analogue bullet cameras',#10209,$,$); +#10213=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_04','Analogue covert cameras',#10209,$,$); +#10214=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_05','Analogue fixed dome cameras',#10209,$,$); +#10215=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_06','Analogue pan, tilt, zoom (PTZ) cameras',#10209,$,$); +#10216=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_07','Box cameras',#10209,$,$); +#10217=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_08','Box camera lenses',#10209,$,$); +#10218=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_09','Bullet cameras',#10209,$,$); +#10219=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_10','Camera junction boxes',#10209,$,$); +#10220=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_11','Covert cameras',#10209,$,$); +#10221=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_21','Day night cameras',#10209,$,$); +#10222=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_24','Dome cameras',#10209,$,$); +#10223=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_30','Fixed cameras',#10209,$,$); +#10224=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_31','Fixed dome cameras',#10209,$,$); +#10225=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_40','Image processing units',#10209,$,$); +#10226=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_41','Infra-red cameras',#10209,$,$); +#10227=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_42','Infrared illuminators',#10209,$,$); +#10228=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_45','Integrated digital camera and infrared illuminators',#10209,$,$); +#10229=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_47','Lenses',#10209,$,$); +#10230=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_60','Pan and tilt units',#10209,$,$); +#10231=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_65','Pan, tilt, zoom cameras',#10209,$,$); +#10232=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_79','Surveillance monitors',#10209,$,$); +#10233=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_80','Survey cameras',#10209,$,$); +#10234=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_90','Traffic enforcement cameras',#10209,$,$); +#10235=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_92','Video distribution amplifiers',#10209,$,$); +#10236=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_94','Video receiver hubs',#10209,$,$); +#10237=IFCCLASSIFICATIONREFERENCE($,'Pr_60_75_86_99','Zoom lenses',#10209,$,$); +#10238=IFCCLASSIFICATIONREFERENCE($,'Pr_65','Services distribution products',#4923,$,$); +#10239=IFCCLASSIFICATIONREFERENCE($,'Pr_65_12','Chutes',#10238,$,$); +#10240=IFCCLASSIFICATIONREFERENCE($,'Pr_65_12_70','Refuse and linen chutes',#10239,$,$); +#10241=IFCCLASSIFICATIONREFERENCE($,'Pr_65_12_70_22','Disposal chutes',#10240,$,$); +#10242=IFCCLASSIFICATIONREFERENCE($,'Pr_65_12_70_47','Linen chutes',#10240,$,$); +#10243=IFCCLASSIFICATIONREFERENCE($,'Pr_65_12_71','Refuse and linen chute accessories',#10239,$,$); +#10244=IFCCLASSIFICATIONREFERENCE($,'Pr_65_12_71_12','Chute cleaning mechanisms',#10243,$,$); +#10245=IFCCLASSIFICATIONREFERENCE($,'Pr_65_12_71_72','Refuse and recycling separators',#10243,$,$); +#10246=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50','Gutter and fitting products',#10238,$,$); +#10247=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35','Gutters and accessories',#10246,$,$); +#10248=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_02','Aluminium combined fascias, soffits and gutters',#10247,$,$); +#10249=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_04','Aluminium composite valley gutters',#10247,$,$); +#10250=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_06','Aluminium eaves gutters',#10247,$,$); +#10251=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_08','Aluminium valley gutters',#10247,$,$); +#10252=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_09','Box gutter sumps',#10247,$,$); +#10253=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_11','Cast iron eaves gutters',#10247,$,$); +#10254=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_15','Copper eaves gutters',#10247,$,$); +#10255=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_26','Eaves gutter leaf guards',#10247,$,$); +#10256=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_27','Galvanized steel valley gutters',#10247,$,$); +#10257=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_28','Galvanized steel chambered gutters',#10247,$,$); +#10258=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_29','Galvanized steel combined fascias, soffits and gutters',#10247,$,$); +#10259=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_30','Galvanized steel composite gutters',#10247,$,$); +#10260=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_31','Galvanized steel eaves gutters',#10247,$,$); +#10261=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_33','Glass reinforced plastics (GRP) valley gutters',#10247,$,$); +#10262=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_34','Glass reinforced plastics (GRP) composite valley gutters',#10247,$,$); +#10263=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_35','Glass reinforced plastics (GRP) eaves gutters',#10247,$,$); +#10264=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_36','Glass reinforced plastics (GRP) roof gutters',#10247,$,$); +#10265=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_37','Gravity rainwater outlets',#10247,$,$); +#10266=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_38','Gutter linings',#10247,$,$); +#10267=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_40','Hot dip precoated carbon steel combined fascias, soffits and gutters',#10247,$,$); +#10268=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_42','Hot dip precoated carbon steel eaves gutters',#10247,$,$); +#10269=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_43','Hot dip precoated carbon steel valley gutters',#10247,$,$); +#10270=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_47','Lead rainwater chutes',#10247,$,$); +#10271=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_68','Rainwater hoppers',#10247,$,$); +#10272=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_70','Rainwater pipe diverter units',#10247,$,$); +#10273=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_72','Rainwater weirs',#10247,$,$); +#10274=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_81','Siphonic rainwater outlets',#10247,$,$); +#10275=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_82','Stainless steel eaves gutters',#10247,$,$); +#10276=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_83','Stainless steel rainwater chutes',#10247,$,$); +#10277=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_84','Stainless steel valley gutters',#10247,$,$); +#10278=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_92','Unplasticized polyvinyl chloride (PVC-U) eaves gutters',#10247,$,$); +#10279=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_98','Zinc eaves gutters',#10247,$,$); +#10280=IFCCLASSIFICATIONREFERENCE($,'Pr_65_50_35_99','Zinc rainwater chutes',#10247,$,$); +#10281=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52','Pipe, tube and fitting products',#10238,$,$); +#10282=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01','Access and inspection chambers and gullies',#10281,$,$); +#10283=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_01','Access and inspection chambers',#10282,$,$); +#10284=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_02','Access covers and frames',#10282,$,$); +#10285=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_03','Access gratings',#10282,$,$); +#10286=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_04','Aluminium inspection chambers',#10282,$,$); +#10287=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_08','Carbon steel edge strips and frames',#10282,$,$); +#10288=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_09','Carbon steel inspection chambers',#10282,$,$); +#10289=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_14','Concrete access cover seatings',#10282,$,$); +#10290=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_16','Concrete inspection chamber sections',#10282,$,$); +#10291=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_17','Concrete inspection chamber cover slabs',#10282,$,$); +#10292=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_18','Concrete inspection chamber shaft sections',#10282,$,$); +#10293=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_19','Concrete inspection chamber transition sections',#10282,$,$); +#10294=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_20','Concrete manhole base units',#10282,$,$); +#10295=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_21','Concrete manhole chamber sections',#10282,$,$); +#10296=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_22','Concrete manhole shaft sections',#10282,$,$); +#10297=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_23','Concrete manhole transition sections',#10282,$,$); +#10298=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_24','Concrete manholes and soakaway cover slabs',#10282,$,$); +#10299=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_25','Concrete soakaway shaft sections',#10282,$,$); +#10300=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_50','Manhole covers and frames',#10282,$,$); +#10301=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_58','Orifice plate drainage flow controllers',#10282,$,$); +#10302=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_60','Plastics access and inspection chambers',#10282,$,$); +#10303=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_61','Plastics below-ground access or equipment chambers',#10282,$,$); +#10304=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_62','Plastics channels for access chambers',#10282,$,$); +#10305=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_63','Plastics distribution and sampling chambers',#10282,$,$); +#10306=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_64','Plastics inspection chambers',#10282,$,$); +#10307=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_65','Plastics mini inspection chambers',#10282,$,$); +#10308=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_66','Plastics restricted access inspection shafts',#10282,$,$); +#10309=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_67','Plastics sealed access pipes',#10282,$,$); +#10310=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_68','Preformed access ducts',#10282,$,$); +#10311=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_72','Recycled polyethylene (PE) inspection chambers',#10282,$,$); +#10312=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_83','Stainless steel edge strips and frames',#10282,$,$); +#10313=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_84','Stainless steel inspection chambers',#10282,$,$); +#10314=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_86','Surface boxes',#10282,$,$); +#10315=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_01_95','Vortex flow drainage controllers',#10282,$,$); +#10316=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07','Below-ground and pressure drainage pipes and fittings',#10281,$,$); +#10317=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_13','Clay below-ground drainage pipes and fittings',#10316,$,$); +#10318=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_15','Concrete perforated below-ground drainage pipes and fittings for flexible jointing',#10316,$,$); +#10319=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_16','Concrete plain wall below-ground drainage pipes and fittings for flexible jointing',#10316,$,$); +#10320=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_25','Ductile iron pressure pipes and fittings',#10316,$,$); +#10321=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_27','Filtration drainage pipes and fittings',#10316,$,$); +#10322=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_28','Flexible couplings between below-ground drainage pipes',#10316,$,$); +#10323=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_34','Grey cast iron below-ground drainage pipes and fittings',#10316,$,$); +#10324=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_36','High-density polyethylene (HDPE) pressure pipes and fittings',#10316,$,$); +#10325=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_38','High-density polyethylene (HDPE) structured wall below-ground drainage pipes and fittings for flexible jointing',#10316,$,$); +#10326=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_39','High-density polyethylene (HDPE) structured wall below-ground drainage pipes and fittings for welded jointing',#10316,$,$); +#10327=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_40','High-density polyethylene (HDPE) structured wall perforated below-ground drainage pipes and fittings for flexible jointing',#10316,$,$); +#10328=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_58','Oriented unplasticized polyvinyl chloride (PVC-O) pressure pipes and fittings',#10316,$,$); +#10329=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_63','Plastics flexible (coil) perforated wall below-ground drainage pipes and fittings',#10316,$,$); +#10330=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_64','Polypropylene (PP) solid wall below-ground drainage pipes and fittings for flexible jointing',#10316,$,$); +#10331=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_65','Polypropylene (PP) structured wall below-ground drainage pipes and fittings for flexible jointing',#10316,$,$); +#10332=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_66','Polypropylene (PP) structured wall perforated below-ground drainage pipes and fittings for flexible jointing',#10316,$,$); +#10333=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_67','Polypropylene (PP) structured wall below-ground drainage pipes and fittings for welded jointing',#10316,$,$); +#10334=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_75','Saddle connectors to below-ground drainage pipes',#10316,$,$); +#10335=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_84','Steel reinforced polyethylene composite structured wall below ground drainage pipelines for flexible jointing',#10316,$,$); +#10336=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_87','Unplasticized polyvinyl chloride (PVC-U) pressure pipes and fittings',#10316,$,$); +#10337=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_88','Unplasticized polyvinyl chloride (PVC-U) solid wall below-ground drainage pipe and fittings for flexible jointing',#10316,$,$); +#10338=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_89','Unplasticized polyvinyl chloride (PVC-U) solid wall perforated below-ground drainage pipes and fittings for flexible jointing',#10316,$,$); +#10339=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_90','Unplasticized polyvinyl chloride (PVC-U) structured wall below-ground drainage pipes and fittings for flexible jointing',#10316,$,$); +#10340=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_91','Unplasticized polyvinyl chloride (PVC-U) structured wall perforated below-ground drainage pipe and fittings for flexible jointing',#10316,$,$); +#10341=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_92','Unplasticized polyvinyl chloride alloy (PVC-A) pressure pipes and fittings',#10316,$,$); +#10342=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_94','Vitrified clay perforated below-ground drainage pipes and fittings for flexible jointing',#10316,$,$); +#10343=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_96','Vitrified clay plain wall below-ground drainage open butt joint pipes (land drainage tiles) and fittings',#10316,$,$); +#10344=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_97','Vitrified clay plain wall below-ground drainage pipes and fittings for flexible jointing',#10316,$,$); +#10345=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_07_98','Vitrified clay plain wall below-ground drainage pipes and fittings for rigid jointing',#10316,$,$); +#10346=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_20','Culverts',#10281,$,$); +#10347=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_20_15','Concrete arch culverts',#10346,$,$); +#10348=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_20_16','Concrete box culverts',#10346,$,$); +#10349=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_20_17','Concrete bridge culverts',#10346,$,$); +#10350=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_20_18','Concrete pipe arch culverts',#10346,$,$); +#10351=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_20_19','Concrete pipe culverts',#10346,$,$); +#10352=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_20_20','Corrugated steel pipe culverts',#10346,$,$); +#10353=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_20_84','Structural plate corrugated steel pipe culverts',#10346,$,$); +#10354=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24','Drainage gullies and channels',#10281,$,$); +#10355=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_02','Adaptors for above-ground pipe connections to clay drainage pipelines',#10354,$,$); +#10356=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_03','Adaptors for above-ground pipe connections to plastics drainage pipelines',#10354,$,$); +#10357=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_11','Carriageway kerb and drainage channels',#10354,$,$); +#10358=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_12','Cast iron composite gullies',#10354,$,$); +#10359=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_13','Cast iron one piece gullies',#10354,$,$); +#10360=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_14','Cast iron rodding eyes',#10354,$,$); +#10361=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_15','Cast iron sealed access pipes',#10354,$,$); +#10362=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_18','Concrete one piece gullies',#10354,$,$); +#10363=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_24','Drainage channels with gratings',#10354,$,$); +#10364=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_26','Filtration drainage channels',#10354,$,$); +#10365=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_28','Floor channels',#10354,$,$); +#10366=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_29','Floor channel covers and gratings',#10354,$,$); +#10367=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_30','Floor gully covers and gratings',#10354,$,$); +#10368=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_31','Floor gullies',#10354,$,$); +#10369=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_47','Linear slot drainage channels',#10354,$,$); +#10370=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_59','Plastics composite gullies',#10354,$,$); +#10371=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_60','Plastics one piece gullies',#10354,$,$); +#10372=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_61','Plastics rodding eyes',#10354,$,$); +#10373=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_64','Polypropylene (PP) composite gullies',#10354,$,$); +#10374=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_65','Polypropylene (PP) one piece gullies',#10354,$,$); +#10375=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_73','Rat barrier pipes',#10354,$,$); +#10376=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_85','Stainless steel rodding eyes',#10354,$,$); +#10377=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_91','Vitrified clay access chamber channels',#10354,$,$); +#10378=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_92','Vitrified clay composite gullies',#10354,$,$); +#10379=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_94','Vitrified clay one piece gullies',#10354,$,$); +#10380=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_95','Vitrified clay rodding eyes',#10354,$,$); +#10381=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_24_96','Vitrified clay sealed access pipes',#10354,$,$); +#10382=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25','Drainage traps and accessories',#10281,$,$); +#10383=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25_06','Below-ground grease traps and converters',#10382,$,$); +#10384=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25_15','Concrete silt traps',#10382,$,$); +#10385=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25_23','Depressurization sumps',#10382,$,$); +#10386=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25_27','Enzyme dosing units',#10382,$,$); +#10387=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25_32','Free-standing grease traps and converters',#10382,$,$); +#10388=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25_60','Petrol interceptors',#10382,$,$); +#10389=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25_62','Plastics silt traps',#10382,$,$); +#10390=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25_72','Reverse action interceptors',#10382,$,$); +#10391=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25_75','Sanitary appliance traps',#10382,$,$); +#10392=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25_78','Silt buckets',#10382,$,$); +#10393=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25_93','Vitrified clay interceptor traps',#10382,$,$); +#10394=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25_96','Vitrified clay silt traps',#10382,$,$); +#10395=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_25_98','Waste traps',#10382,$,$); +#10396=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34','Gauges and sight glasses',#10281,$,$); +#10397=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34_08','Bourdon tube pressure gauges',#10396,$,$); +#10398=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34_15','Combined steam sight glass and check valves',#10396,$,$); +#10399=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34_16','Contents gauges',#10396,$,$); +#10400=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34_18','Contents sight glasses',#10396,$,$); +#10401=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34_22','Differential pressure gauges',#10396,$,$); +#10402=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34_24','Double window steam sight glasses',#10396,$,$); +#10403=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34_48','Manifold gauges',#10396,$,$); +#10404=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34_50','Manometers',#10396,$,$); +#10405=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34_55','Multi window steam sight glasses',#10396,$,$); +#10406=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34_65','Pressure and altitude gauges',#10396,$,$); +#10407=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34_66','Pressure gauges',#10396,$,$); +#10408=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34_77','Single window steam sight glasses',#10396,$,$); +#10409=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_34_88','Temperature gauges',#10396,$,$); +#10410=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38','Hoses, hose reels and ancillaries',#10281,$,$); +#10411=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_14','Compressed air coil hoses',#10410,$,$); +#10412=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_15','Compressed air hose couplings',#10410,$,$); +#10413=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_16','Compressed air hose reel balancers',#10410,$,$); +#10414=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_18','Compressed air hose reels',#10410,$,$); +#10415=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_20','Crushproof vehicle exhaust hoses',#10410,$,$); +#10416=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_30','Fire hose reels',#10410,$,$); +#10417=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_31','Flat irrigation hoses',#10410,$,$); +#10418=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_32','Foam hose couplings',#10410,$,$); +#10419=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_33','Gas hose reels',#10410,$,$); +#10420=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_42','Irrigation hoses',#10410,$,$); +#10421=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_48','Liquid petroleum gas (LPG) rubber hoses and hose assemblies',#10410,$,$); +#10422=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_69','Quick release couplings',#10410,$,$); +#10423=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_71','Reinforced wall hoses',#10410,$,$); +#10424=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_84','Spiral compressed air hoses',#10410,$,$); +#10425=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_85','Spiral plastics hoses',#10410,$,$); +#10426=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_86','Spring balancer vehicle exhaust hose supports',#10410,$,$); +#10427=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_94','Vehicle exhaust hose reels',#10410,$,$); +#10428=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_95','Water hose reels',#10410,$,$); +#10429=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_96','Water hoses',#10410,$,$); +#10430=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_97','Water fire extinguishing hose couplings',#10410,$,$); +#10431=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_38_98','WC washdown hoses',#10410,$,$); +#10432=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61','Pipe accessories',#10281,$,$); +#10433=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_04','Anti-climb pipe covers',#10432,$,$); +#10434=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_15','Concealed intumescent pipe collars',#10432,$,$); +#10435=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_22','Dirt pockets',#10432,$,$); +#10436=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_23','Discharge and ventilating stack terminations',#10432,$,$); +#10437=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_42','Insulated wrap pipe collars',#10432,$,$); +#10438=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_50','Masking plates',#10432,$,$); +#10439=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_61','Pipe ducts',#10432,$,$); +#10440=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_62','Pipeline supports',#10432,$,$); +#10441=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_63','Pipe sleeves',#10432,$,$); +#10442=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_64','Pipe sleeve seals',#10432,$,$); +#10443=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_65','Plastics ducts for electric cables',#10432,$,$); +#10444=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_68','Puddle flanges',#10432,$,$); +#10445=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_72','Radiator pipe seals',#10432,$,$); +#10446=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_86','Surface-mounted intumescent pipe collars',#10432,$,$); +#10447=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_91','Tundishes',#10432,$,$); +#10448=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_61_96','Wall collars',#10432,$,$); +#10449=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62','Pipe jointing materials',#10281,$,$); +#10450=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_03','Anaerobic sealants',#10449,$,$); +#10451=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_09','Brazing compounds',#10449,$,$); +#10452=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_11','Caulking ropes',#10449,$,$); +#10453=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_25','Elastomeric pipe joint gaskets',#10449,$,$); +#10454=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_27','Elastomeric ring seals',#10449,$,$); +#10455=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_28','Flange adaptors',#10449,$,$); +#10456=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_29','Flange jointing rings for copper flanges',#10449,$,$); +#10457=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_30','Flange jointing rings for stainless steel flanges',#10449,$,$); +#10458=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_31','Flange jointing rings for steel flanges',#10449,$,$); +#10459=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_32','Flux',#10449,$,$); +#10460=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_36','Hemps and pastes',#10449,$,$); +#10461=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_50','Mechanical couplings',#10449,$,$); +#10462=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_62','Pipeline connectors',#10449,$,$); +#10463=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_65','Polytetrafluoroethylene (PTFE) joint tapes',#10449,$,$); +#10464=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_71','Resin modified cements',#10449,$,$); +#10465=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_81','Solders',#10449,$,$); +#10466=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_62_82','Solvent welding cements',#10449,$,$); +#10467=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63','Pipes and fittings',#10281,$,$); +#10468=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_02','Acrylonitrile butadiene styrene (ABS) pipes and fittings',#10467,$,$); +#10469=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_03','Acrylonitrile butadiene styrene (ABS) fittings',#10467,$,$); +#10470=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_04','Aluminium rainwater pipe and fittings',#10467,$,$); +#10471=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_08','Borosilicate glass pipe and fittings',#10467,$,$); +#10472=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_10','Carbon steel pipe and fittings',#10467,$,$); +#10473=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_11','Cast iron rainwater pipe and fittings',#10467,$,$); +#10474=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_12','Cast iron drainage pipe and fittings',#10467,$,$); +#10475=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_13','Chlorinated polyvinyl chloride (PVC-C) pipe and fittings',#10467,$,$); +#10476=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_14','Chlorinated polyvinyl chloride (PVC-C) pipelines',#10467,$,$); +#10477=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_15','Concrete perforated pipes and fittings',#10467,$,$); +#10478=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_16','Concrete pipes and fittings',#10467,$,$); +#10479=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_17','Copper pipelines',#10467,$,$); +#10480=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_18','Copper pipeline fittings',#10467,$,$); +#10481=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_19','Copper rainwater pipes and fittings',#10467,$,$); +#10482=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_20','Copper refrigerant pipelines',#10467,$,$); +#10483=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_21','Copper waste water pipe and fittings',#10467,$,$); +#10484=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_22','Corrugated stainless steel pipes and fittings',#10467,$,$); +#10485=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_23','Cross-linked polyethylene (PE-X) pipes and fittings',#10467,$,$); +#10486=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_25','Ductile iron pipes and fittings',#10467,$,$); +#10487=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_29','Flexible composite pipelines for liquid fuels',#10467,$,$); +#10488=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_30','Hot dip precoated carbon steel rainwater pipe and fittings',#10467,$,$); +#10489=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_31','Galvanized steel rainwater pipe and fittings',#10467,$,$); +#10490=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_32','Glass pipelines',#10467,$,$); +#10491=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_33','Glass reinforced plastics (GRP) pressure pipes and fittings',#10467,$,$); +#10492=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_34','Glass reinforced plastics (GRP) rainwater pipes and fittings',#10467,$,$); +#10493=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_35','Glass reinforced plastics (GRP) pipe and fittings for liquid fuels',#10467,$,$); +#10494=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_46','Lead pipes and fittings',#10467,$,$); +#10495=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_50','Medical gas copper tube',#10467,$,$); +#10496=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_52','Modified unplasticized polyvinyl chloride (MUPVC) pipes and fittings',#10467,$,$); +#10497=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_54','Multilayer pipelines for gaseous fuels',#10467,$,$); +#10498=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_55','Multilayer pipelines for water',#10467,$,$); +#10499=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_60','Polybutylene (PB) pipes and fittings',#10467,$,$); +#10500=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_61','Polyethylene (PE) drainage pipe and fittings',#10467,$,$); +#10501=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_62','Polyethylene (PE) gaseous fuel pipes and fittings',#10467,$,$); +#10502=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_63','Polyethylene (PE) water pipes and fittings',#10467,$,$); +#10503=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_64','Polyethylene (PE) pipes for liquid fuels',#10467,$,$); +#10504=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_65','Polypropylene (PP) pipelines',#10467,$,$); +#10505=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_66','Polypropylene (PP) solid wall pipes and fittings',#10467,$,$); +#10506=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_67','Polypropylene (PP) structured wall pipes and fittings',#10467,$,$); +#10507=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_68','Pre-insulated pipelines',#10467,$,$); +#10508=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_70','Propylene copolymer pressure pipes and fittings',#10467,$,$); +#10509=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_78','Stainless steel pipelines',#10467,$,$); +#10510=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_79','Stainless steel pipeline fittings',#10467,$,$); +#10511=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_80','Stainless steel rainwater pipes and fittings',#10467,$,$); +#10512=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_81','Stainless steel waste water pipes and fittings',#10467,$,$); +#10513=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_82','Steel pipelines',#10467,$,$); +#10514=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_83','Steel pipeline fittings',#10467,$,$); +#10515=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_84','Steel pipe and fittings for liquid fuels',#10467,$,$); +#10516=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_87','Unplasticized polyvinyl chloride (PVC-U) drainage pipe and fittings',#10467,$,$); +#10517=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_88','Unplasticized polyvinyl chloride (PVC-U) rainwater pipes and fittings',#10467,$,$); +#10518=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_89','Unplasticized polyvinyl chloride (PVC-U) pipelines',#10467,$,$); +#10519=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_90','Unplasticized polyvinyl chloride (PVC-U) solid wall pipes and fittings',#10467,$,$); +#10520=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_91','Unplasticized polyvinyl chloride (PVC-U) structured wall perforated pipes and fittings',#10467,$,$); +#10521=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_92','Unplasticized polyvinyl chloride (PVC-U) structured wall pipes and fittings',#10467,$,$); +#10522=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_93','Unplasticized polyvinyl chloride alloy (PVC-A) pipes and fittings',#10467,$,$); +#10523=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_94','Vitrified clay perforated pipes and fittings',#10467,$,$); +#10524=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_95','Vitrified clay plain wall open butt joint pipes and fittings',#10467,$,$); +#10525=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_96','Vitrified clay plain wall pipes and fittings',#10467,$,$); +#10526=IFCCLASSIFICATIONREFERENCE($,'Pr_65_52_63_99','Zinc rainwater pipes and fittings',#10467,$,$); +#10527=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53','Pump products',#10238,$,$); +#10528=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_24','Drainage pumps',#10527,$,$); +#10529=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_24_80','Small bore discharge macerator and pumps',#10528,$,$); +#10530=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_24_81','Small bore discharge pumps',#10528,$,$); +#10531=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_24_86','Submersible pumps',#10528,$,$); +#10532=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_65','Pump accessories',#10527,$,$); +#10533=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_65_04','Auto-coupling sets',#10532,$,$); +#10534=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86','Supply and exhaust pumps',#10527,$,$); +#10535=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_05','Automatic condensate pumps',#10534,$,$); +#10536=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_07','Belt driven end suction pumps',#10534,$,$); +#10537=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_11','Canned rotor pumps',#10534,$,$); +#10538=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_12','Centrifugal pumps',#10534,$,$); +#10539=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_13','Close-coupled end suction pumps',#10534,$,$); +#10540=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_15','Close-coupled in line pumps',#10534,$,$); +#10541=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_17','Condensate recovery units',#10534,$,$); +#10542=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_24','Dosing pump units',#10534,$,$); +#10543=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_32','Fuel oil transfer pumps',#10534,$,$); +#10544=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_33','Gas boosters',#10534,$,$); +#10545=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_50','Medical gas exhauster units',#10534,$,$); +#10546=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_51','Metering pumps',#10534,$,$); +#10547=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_55','Multi-stage pumps',#10534,$,$); +#10548=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_66','Pressure booster pumps',#10534,$,$); +#10549=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_68','Pressurization units',#10534,$,$); +#10550=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_86','Suction pumps',#10534,$,$); +#10551=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_86_94','Vapour pumps',#10534,$,$); +#10552=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96','Water supply and wastewater pumps',#10527,$,$); +#10553=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_02','Air lift pumps',#10552,$,$); +#10554=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_03','Archimedes screw pumps',#10552,$,$); +#10555=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_04','Axial flow pumps',#10552,$,$); +#10556=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_05','Axially split casing pumps',#10552,$,$); +#10557=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_06','Back pull-out end suction pumps',#10552,$,$); +#10558=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_21','Double diaphragm pumps',#10552,$,$); +#10559=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_23','Double disc pumps',#10552,$,$); +#10560=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_27','Electromagnetic pumps',#10552,$,$); +#10561=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_41','Inline multistage pumps',#10552,$,$); +#10562=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_44','Jet pumps',#10552,$,$); +#10563=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_50','Macerators',#10552,$,$); +#10564=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_51','Magnetic drive pumps',#10552,$,$); +#10565=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_55','Multistage centrifugal pumps',#10552,$,$); +#10566=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_63','Peristaltic pumps',#10552,$,$); +#10567=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_64','Positive displacement pumps',#10552,$,$); +#10568=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_65','Positive inlet pressure booster sets',#10552,$,$); +#10569=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_66','Progressing cavity pumps',#10552,$,$); +#10570=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_70','Ram pumps',#10552,$,$); +#10571=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_72','Rotary gear pumps',#10552,$,$); +#10572=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_73','Rotary lobe pumps',#10552,$,$); +#10573=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_74','Rotary vane pumps',#10552,$,$); +#10574=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_75','Screw pumps',#10552,$,$); +#10575=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_78','Single diaphragm pumps',#10552,$,$); +#10576=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_79','Single stage centrifugal pumps',#10552,$,$); +#10577=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_80','Solids handling pumps',#10552,$,$); +#10578=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_84','Submersible borehole pumps',#10552,$,$); +#10579=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_85','Submersible axial pumps',#10552,$,$); +#10580=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_86','Submersible centrifugal pumps',#10552,$,$); +#10581=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_87','Submersible mixed flow pumps',#10552,$,$); +#10582=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_94','Vertically suspended bowl type pumps',#10552,$,$); +#10583=IFCCLASSIFICATIONREFERENCE($,'Pr_65_53_96_95','Volute casing dry well centrifugal sewage and sludge pumps',#10552,$,$); +#10584=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54','Valve products',#10238,$,$); +#10585=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_24','Drainage valves',#10584,$,$); +#10586=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_24_02','Air admittance valves',#10585,$,$); +#10587=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_24_04','Anti-flood valves',#10585,$,$); +#10588=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30','Fire fighting valves and devices',#10584,$,$); +#10589=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_02','Alarm test valve assemblies',#10588,$,$); +#10590=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_09','Carbon dioxide connectors',#10588,$,$); +#10591=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_10','Caps and chains',#10588,$,$); +#10592=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_11','Carbon dioxide odorizing devices',#10588,$,$); +#10593=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_12','Check and non-return valves',#10588,$,$); +#10594=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_15','Container gas fire extinguishing valves',#10588,$,$); +#10595=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_22','Deluge valves',#10588,$,$); +#10596=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_23','Drain and test valves',#10588,$,$); +#10597=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_24','Dry riser landing valves',#10588,$,$); +#10598=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_25','Dry dropper outlet valves',#10588,$,$); +#10599=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_30','Fire fighting alarm devices',#10588,$,$); +#10600=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_32','Fusible links',#10588,$,$); +#10601=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_34','Gas fire suppression manifolds',#10588,$,$); +#10602=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_35','Gas fire suppression pressure gauges',#10588,$,$); +#10603=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_36','Gas fire suppression pressure switches',#10588,$,$); +#10604=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_37','High and low pressure selector gas fire extinguishing valves',#10588,$,$); +#10605=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_42','Inlet breechings',#10588,$,$); +#10606=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_50','Multiple control valves',#10588,$,$); +#10607=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_63','Pneumatic alarm devices',#10588,$,$); +#10608=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_85','Sprinkler system alarm valves',#10588,$,$); +#10609=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_95','Water fire extinguisher leather straps',#10588,$,$); +#10610=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_96','Water mist control valves',#10588,$,$); +#10611=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_30_97','Wet riser landing valves',#10588,$,$); +#10612=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33','Gas and liquid fuel valves',#10584,$,$); +#10613=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_03','Anti-siphon liquid fuel supply valves',#10612,$,$); +#10614=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_05','Automatic changeover liquid petroleum gas (LPG) valves',#10612,$,$); +#10615=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_10','Chlorine gas injectors',#10612,$,$); +#10616=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_11','Cast iron plug valves',#10612,$,$); +#10617=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_12','Chlorine gas manifolds',#10612,$,$); +#10618=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_13','Chlorine gas manifold pigtails',#10612,$,$); +#10619=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_14','Compressed air manifolds',#10612,$,$); +#10620=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_15','Compressed air pressure reducing stations',#10612,$,$); +#10621=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_17','Compressed air safety valves',#10612,$,$); +#10622=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_31','Fusible link drop weight valves',#10612,$,$); +#10623=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_33','Gas ball valves',#10612,$,$); +#10624=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_34','Gas burner safety devices',#10612,$,$); +#10625=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_35','Gas butterfly valves',#10612,$,$); +#10626=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_36','Gas pressure reducing stations',#10612,$,$); +#10627=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_37','Gas pressure switches',#10612,$,$); +#10628=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_38','Gas solenoid valves',#10612,$,$); +#10629=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_40','Gas vacuum regulators',#10612,$,$); +#10630=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_43','Industrial vacuum flow regulating valves',#10612,$,$); +#10631=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_44','Laboratory gas safety valves',#10612,$,$); +#10632=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_45','Laboratory gas taps',#10612,$,$); +#10633=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_46','Laboratory gas supply manifolds',#10612,$,$); +#10634=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_47','Liquefied petroleum gas (LPG) pressure regulators',#10612,$,$); +#10635=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_48','Liquefied petroleum gas (LPG) pressure relief valves',#10612,$,$); +#10636=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_49','Liquefied petroleum gas (LPG) shut off valves and emergency valves',#10612,$,$); +#10637=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_50','Mechanical gas safety valves',#10612,$,$); +#10638=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_51','Medical gas line valves',#10612,$,$); +#10639=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_52','Medical gas pressure reducing stations',#10612,$,$); +#10640=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_53','Medical gas service modules',#10612,$,$); +#10641=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_54','Medical gas supply manifolds',#10612,$,$); +#10642=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_55','Medical gas valve service units',#10612,$,$); +#10643=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_57','Medical vacuum flow regulating valves',#10612,$,$); +#10644=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_65','Pressure vacuum valves',#10612,$,$); +#10645=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_70','Refrigerant safety devices',#10612,$,$); +#10646=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_71','Remote acting fire safety liquid fuel supply valves',#10612,$,$); +#10647=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_74','Rupture discs',#10612,$,$); +#10648=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_76','Self-sealing liquid petroleum gas (LPG) couplers',#10612,$,$); +#10649=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_78','Shear valves',#10612,$,$); +#10650=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_84','Steel plug valves',#10612,$,$); +#10651=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_87','Taper plug valves',#10612,$,$); +#10652=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_93','Vacuum switches',#10612,$,$); +#10653=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_33_94','Vapour connection adaptors',#10612,$,$); +#10654=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_40','Irrigation valves',#10584,$,$); +#10655=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_40_02','Air valves',#10654,$,$); +#10656=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_40_13','Check valves',#10654,$,$); +#10657=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_40_16','Control valves',#10654,$,$); +#10658=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_40_44','Isolating valves',#10654,$,$); +#10659=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_40_62','Plastics isolating valves',#10654,$,$); +#10660=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_40_94','Volumetric control valves',#10654,$,$); +#10661=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_85','Steam valves',#10584,$,$); +#10662=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_85_06','Balanced pressure air vents',#10661,$,$); +#10663=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_85_07','Bellows sealed stop valves',#10661,$,$); +#10664=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_85_08','Blowdown valves',#10661,$,$); +#10665=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_85_22','Direct-acting pressure-reducing valves',#10661,$,$); +#10666=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_85_26','Electrically-actuated control steam valves',#10661,$,$); +#10667=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_85_60','Pilot-operated pressure-reducing valves',#10661,$,$); +#10668=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_85_62','Piston stop valves',#10661,$,$); +#10669=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_85_65','Pneumatically-actuated control steam valves',#10661,$,$); +#10670=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_85_77','Self-acting control steam valves',#10661,$,$); +#10671=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_85_78','Self-acting steam temperature valves',#10661,$,$); +#10672=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_85_79','Self-operating control valves',#10661,$,$); +#10673=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_85_88','Temperature and pressure control steam valves',#10661,$,$); +#10674=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_93','Valve accessories',#10584,$,$); +#10675=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_93_05','Automatic air vents',#10674,$,$); +#10676=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_93_06','Ball valve floats',#10674,$,$); +#10677=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_93_50','Manual air vents',#10674,$,$); +#10678=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_93_87','Test points',#10674,$,$); +#10679=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_93_88','T-keys',#10674,$,$); +#10680=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_93_94','Valve keys',#10674,$,$); +#10681=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94','Water supply valves',#10584,$,$); +#10682=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_03','Anti-pollution check valves',#10681,$,$); +#10683=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_11','Cast iron wedge gate valves',#10681,$,$); +#10684=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_22','Direct acting float actuated automatic control valves',#10681,$,$); +#10685=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_23','Direct spring operated pressure relief valves',#10681,$,$); +#10686=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_24','Double orifice air valves',#10681,$,$); +#10687=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_26','Eccentric plug valves',#10681,$,$); +#10688=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_29','Flap valves',#10681,$,$); +#10689=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_30','Flexible rubber check valves',#10681,$,$); +#10690=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_31','Free discharge valves',#10681,$,$); +#10691=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_39','Hydrostatic bellmouth valves',#10681,$,$); +#10692=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_45','Knife gate valves',#10681,$,$); +#10693=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_47','Line pressure driven automatic control valves',#10681,$,$); +#10694=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_50','Metallic butterfly valves',#10681,$,$); +#10695=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_55','Needle valves',#10681,$,$); +#10696=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_56','Non-slam nozzle check valves',#10681,$,$); +#10697=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_57','Non-slam twin plate check valves',#10681,$,$); +#10698=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_60','Pallet type pressure relief valves',#10681,$,$); +#10699=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_62','Pilot operated valves',#10681,$,$); +#10700=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_63','Pinch type pressure relief valves',#10681,$,$); +#10701=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_65','Plunger valves',#10681,$,$); +#10702=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_70','Recoil resilient hinge disc check valves',#10681,$,$); +#10703=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_71','Recoil swing disc check valves',#10681,$,$); +#10704=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_72','Reduced pressure zone valves',#10681,$,$); +#10705=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_73','Resilient hinge disc check valves',#10681,$,$); +#10706=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_77','Single large orifice air valves',#10681,$,$); +#10707=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_78','Single small orifice air valves',#10681,$,$); +#10708=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_87','Solenoid operated valves',#10681,$,$); +#10709=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_90','Triple orifice air valves',#10681,$,$); +#10710=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_94','Vacuum breaker air valves',#10681,$,$); +#10711=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_94_95','V-port ball valves',#10681,$,$); +#10712=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95','Water services valves',#10584,$,$); +#10713=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_05','Backflow prevention check valves',#10712,$,$); +#10714=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_06','Ball valves',#10712,$,$); +#10715=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_08','Butterfly valves',#10712,$,$); +#10716=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_11','Cast iron check valves',#10712,$,$); +#10717=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_12','Cast iron gate valves',#10712,$,$); +#10718=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_13','Cast iron globe valves',#10712,$,$); +#10719=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_14','Copper alloy check valves',#10712,$,$); +#10720=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_15','Copper alloy gate valves',#10712,$,$); +#10721=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_16','Copper alloy globe valves',#10712,$,$); +#10722=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_18','Copper alloy service stop valves',#10712,$,$); +#10723=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_19','Copper alloy stop valves',#10712,$,$); +#10724=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_20','Copper alloy underground stop valves',#10712,$,$); +#10725=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_21','Commissioning manifolds',#10712,$,$); +#10726=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_23','Draw off taps',#10712,$,$); +#10727=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_24','Diaphragm valves',#10712,$,$); +#10728=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_25','Differential pressure control valves',#10712,$,$); +#10729=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_26','Double regulating valves',#10712,$,$); +#10730=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_27','Draining taps',#10712,$,$); +#10731=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_28','Excess pressure valves',#10712,$,$); +#10732=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_29','Float-operated valves',#10712,$,$); +#10733=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_30','Flow measuring valves',#10712,$,$); +#10734=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_31','Flow-reducing servicing valves',#10712,$,$); +#10735=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_33','Foot valves',#10712,$,$); +#10736=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_38','Hose union backflow prevention devices',#10712,$,$); +#10737=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_42','In-line anti-vacuum backflow prevention devices',#10712,$,$); +#10738=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_47','Low pressure thermostatic mixing valves',#10712,$,$); +#10739=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_48','Low temperature thermostatic mixing valves',#10712,$,$); +#10740=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_50','Metering valves',#10712,$,$); +#10741=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_53','Motorized valves',#10712,$,$); +#10742=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_63','Pressure independent control valves',#10712,$,$); +#10743=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_64','Pressure regulating valves',#10712,$,$); +#10744=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_65','Pressure relief valves',#10712,$,$); +#10745=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_66','Pressure reducing valves',#10712,$,$); +#10746=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_67','Pressure surplussing valves',#10712,$,$); +#10747=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_70','Radiator valves',#10712,$,$); +#10748=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_75','Safety valves',#10712,$,$); +#10749=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_80','Steel alloy check valves',#10712,$,$); +#10750=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_81','Steel ball valves',#10712,$,$); +#10751=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_82','Steel globe valves',#10712,$,$); +#10752=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_83','Steel globe stop and check valves',#10712,$,$); +#10753=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_86','Thermostatic balancing valves',#10712,$,$); +#10754=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_87','Tempering valves',#10712,$,$); +#10755=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_88','Thermostatic mixing valves',#10712,$,$); +#10756=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_89','Thermostatic radiator valves',#10712,$,$); +#10757=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_90','Three-way vent cocks',#10712,$,$); +#10758=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_92','Underfloor heating and cooling manifolds',#10712,$,$); +#10759=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_94','Verifiable backflow prevention devices',#10712,$,$); +#10760=IFCCLASSIFICATIONREFERENCE($,'Pr_65_54_95_96','Waterworks gate valves',#10712,$,$); +#10761=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55','Liquid and gas distribution products',#10238,$,$); +#10762=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_62','Phase change distribution products',#10761,$,$); +#10763=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_62_12','Chlorine catchpots',#10762,$,$); +#10764=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_62_47','Liquefied petroleum gas (LPG) vaporizers',#10762,$,$); +#10765=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_76','Separators',#10761,$,$); +#10766=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_76_04','Austenitic stainless steel steam separators',#10765,$,$); +#10767=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_76_11','Carbon steel steam separators',#10765,$,$); +#10768=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_76_12','Cast iron steam separators',#10765,$,$); +#10769=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_76_13','Centrifugal air separators',#10765,$,$); +#10770=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_76_15','Combined air and dirt separators',#10765,$,$); +#10771=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_76_22','Dirt separators',#10765,$,$); +#10772=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_76_58','Oil and petrol separators',#10765,$,$); +#10773=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_76_59','Oil and water separators',#10765,$,$); +#10774=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_76_77','SG iron steam separators',#10765,$,$); +#10775=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_76_84','Stainless steel steam separators',#10765,$,$); +#10776=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_76_96','Water separators',#10765,$,$); +#10777=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_84','Steam and condensate distribution products',#10761,$,$); +#10778=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_84_50','Steam manifolds',#10777,$,$); +#10779=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_84_75','Sample coolers',#10777,$,$); +#10780=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_84_94','Vacuum breakers',#10777,$,$); +#10781=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_85','Steam and condensate recovery vessels',#10761,$,$); +#10782=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_85_08','Blowdown vessels',#10781,$,$); +#10783=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_85_30','Flash steam recovery vessels',#10781,$,$); +#10784=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_85_85','Steam feedtanks',#10781,$,$); +#10785=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_86','Steam traps and strainers',#10761,$,$); +#10786=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_86_05','Angle steam strainers',#10785,$,$); +#10787=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_86_06','Balanced pressure steam traps',#10785,$,$); +#10788=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_86_07','Ball float steam traps',#10785,$,$); +#10789=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_86_08','Bimetallic steam traps',#10785,$,$); +#10790=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_86_42','Inverted bucket steam traps',#10785,$,$); +#10791=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_86_88','Thermodynamic steam traps',#10785,$,$); +#10792=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_86_89','Thermostatic steam traps',#10785,$,$); +#10793=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_86_99','Y-type steam strainers',#10785,$,$); +#10794=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_96','Washing products',#10761,$,$); +#10795=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_96_24','Drive-through wheel wash',#10794,$,$); +#10796=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_96_72','Roller wheel wash',#10794,$,$); +#10797=IFCCLASSIFICATIONREFERENCE($,'Pr_65_55_96_96','Wash plant',#10794,$,$); +#10798=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57','Filter products',#10238,$,$); +#10799=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02','Air filters',#10798,$,$); +#10800=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_02','Activated carbon air filters',#10799,$,$); +#10801=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_03','Air gas and vapour cleaners',#10799,$,$); +#10802=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_04','Air particle cleaners',#10799,$,$); +#10803=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_06','Baffle grease air filters',#10799,$,$); +#10804=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_07','Bag air filters',#10799,$,$); +#10805=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_11','Cartridge grease air filters',#10799,$,$); +#10806=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_15','Cold water mist grease air filters',#10799,$,$); +#10807=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_20','Cyclone filters',#10799,$,$); +#10808=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_25','Duct-mounted modular electrostatic air filters',#10799,$,$); +#10809=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_26','Efficient particulate arrestor (EPA) air filters',#10799,$,$); +#10810=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_28','Electrostatic precipitators',#10799,$,$); +#10811=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_29','Fabric filters',#10799,$,$); +#10812=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_37','High efficiency particle arrestor (HEPA) air filters',#10799,$,$); +#10813=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_52','Mesh air filters',#10799,$,$); +#10814=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_66','Panel air filters',#10799,$,$); +#10815=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_70','Safe change filter changing units',#10799,$,$); +#10816=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_92','Ultra low particle arrestor (ULPA) air filters',#10799,$,$); +#10817=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_93','Ultraviolet light grease filters',#10799,$,$); +#10818=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_96','Water wash grease air filters',#10799,$,$); +#10819=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_02_97','Wet scrubber filters',#10799,$,$); +#10820=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_33','Gas and air filters',#10798,$,$); +#10821=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_33_02','Activated carbon compressed air filters',#10820,$,$); +#10822=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_33_15','Coalescing compressed air filters',#10820,$,$); +#10823=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_33_25','Dust compressed air filters',#10820,$,$); +#10824=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_33_33','Gas filters',#10820,$,$); +#10825=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_58','Oil filters and strainers',#10798,$,$); +#10826=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_58_58','Oil filters',#10825,$,$); +#10827=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_58_59','Oil strainers',#10825,$,$); +#10828=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_85','Swimming pool water filters and strainers',#10798,$,$); +#10829=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_85_06','Basket filters',#10828,$,$); +#10830=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_85_07','Basket strainers',#10828,$,$); +#10831=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_85_12','Cartridge pool water filters',#10828,$,$); +#10832=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_85_22','Diatomaceous earth water filters',#10828,$,$); +#10833=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_85_33','Glass media water filters',#10828,$,$); +#10834=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_85_65','Pressure water filters',#10828,$,$); +#10835=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_85_70','Regenerative water filters',#10828,$,$); +#10836=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_85_75','Sand water filters',#10828,$,$); +#10837=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_95','Water feature filters and strainers',#10798,$,$); +#10838=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_95_07','Biological filters',#10837,$,$); +#10839=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_95_11','Cartridge water filters',#10837,$,$); +#10840=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_95_13','Centrifugal particle separators',#10837,$,$); +#10841=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_95_22','Disc filters',#10837,$,$); +#10842=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_95_42','Inline water filters',#10837,$,$); +#10843=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_95_51','Media water filters',#10837,$,$); +#10844=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_95_76','Screen filters',#10837,$,$); +#10845=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_95_96','Water strainers',#10837,$,$); +#10846=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96','Water filters and strainers',#10798,$,$); +#10847=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_02','Activated carbon water filters',#10846,$,$); +#10848=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_03','Active biological water filters',#10846,$,$); +#10849=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_04','Angle water strainers',#10846,$,$); +#10850=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_08','Basket water strainers',#10846,$,$); +#10851=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_09','Bottle brush water filters',#10846,$,$); +#10852=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_11','Canister water filters',#10846,$,$); +#10853=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_13','Chlorine dioxide biological water filters',#10846,$,$); +#10854=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_16','Conical water filters',#10846,$,$); +#10855=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_29','Fast bed rapid sand water filters',#10846,$,$); +#10856=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_30','Floating tank water filters',#10846,$,$); +#10857=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_34','Granular activated carbon water filters',#10846,$,$); +#10858=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_35','Gravel water filters',#10846,$,$); +#10859=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_52','Membrane water filters',#10846,$,$); +#10860=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_53','Mesh water filters',#10846,$,$); +#10861=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_62','Pilot water filters',#10846,$,$); +#10862=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_70','Rapid gravity water filters',#10846,$,$); +#10863=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_72','Reed bed water filters',#10846,$,$); +#10864=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_77','Side stream water filters',#10846,$,$); +#10865=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_79','Slow bed sand water filters',#10846,$,$); +#10866=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_86','Subsurface vortex water filters',#10846,$,$); +#10867=IFCCLASSIFICATIONREFERENCE($,'Pr_65_57_96_99','Y-type water strainers',#10846,$,$); +#10868=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65','Ductwork products',#10238,$,$); +#10869=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_23','Ductwork accessories',#10868,$,$); +#10870=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_23_20','Duct access panels',#10869,$,$); +#10871=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_23_25','Ductwork access doorsets',#10869,$,$); +#10872=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_24','Duct dampers',#10868,$,$); +#10873=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_24_16','Constant volume boxes',#10872,$,$); +#10874=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_24_29','Fire and smoke dampers',#10872,$,$); +#10875=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_24_30','Fire dampers',#10872,$,$); +#10876=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_24_42','Intumescent fire and smoke dampers',#10872,$,$); +#10877=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_24_56','Non-return dampers',#10872,$,$); +#10878=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_24_66','Pressure control flaps',#10872,$,$); +#10879=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_24_68','Pressure relief dampers',#10872,$,$); +#10880=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_24_78','Shut off dampers',#10872,$,$); +#10881=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_24_80','Smoke dampers',#10872,$,$); +#10882=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_24_93','Variable air volume boxes',#10872,$,$); +#10883=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_24_95','Volume control dampers',#10872,$,$); +#10884=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_25','Ductwork and fittings',#10868,$,$); +#10885=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_25_13','Circular plastics ductwork and fittings',#10884,$,$); +#10886=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_25_14','Circular sheet metal ductwork and fittings',#10884,$,$); +#10887=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_25_23','Domestic rigid ductwork and fittings',#10884,$,$); +#10888=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_25_28','Fabric ductwork and fittings',#10884,$,$); +#10889=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_25_30','Fire resisting ductwork and fittings',#10884,$,$); +#10890=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_25_31','Flat oval sheet metal ductwork and fittings',#10884,$,$); +#10891=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_25_32','Flexible ductwork',#10884,$,$); +#10892=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_25_34','Glass fibre ductwork and fittings',#10884,$,$); +#10893=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_25_64','Pre-insulated ductwork and fittings',#10884,$,$); +#10894=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_25_71','Rectangular plastics ductwork and fittings',#10884,$,$); +#10895=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_25_72','Rectangular sheet metal ductwork and fittings',#10884,$,$); +#10896=IFCCLASSIFICATIONREFERENCE($,'Pr_65_65_25_77','Smoke extract ductwork',#10884,$,$); +#10897=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67','Air and fume distribution products',#10238,$,$); +#10898=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_16','Compressed air products',#10897,$,$); +#10899=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_16_02','Air compressors',#10898,$,$); +#10900=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_16_03','Air-cooled aftercoolers',#10898,$,$); +#10901=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_16_04','Air preparation units',#10898,$,$); +#10902=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_16_05','Air receivers',#10898,$,$); +#10903=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_16_08','Blow protectors',#10898,$,$); +#10904=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_16_22','Desiccant air dryers',#10898,$,$); +#10905=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_16_50','Medical gas compressors',#10898,$,$); +#10906=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_16_71','Refrigerant air dryers',#10898,$,$); +#10907=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_16_96','Water-cooled aftercoolers',#10898,$,$); +#10908=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_22','De-aerators',#10897,$,$); +#10909=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_22_47','Liquid fuel de-aerators',#10908,$,$); +#10910=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_22_66','Pressure differential de-aerators',#10908,$,$); +#10911=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_22_88','Temperature differential de-aerators',#10908,$,$); +#10912=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_28','Expansion compensators',#10897,$,$); +#10913=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_28_03','Angular expansion compensators',#10912,$,$); +#10914=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_28_05','Axial expansion compensators',#10912,$,$); +#10915=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_28_46','Lateral expansion compensators',#10912,$,$); +#10916=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29','Fans',#10897,$,$); +#10917=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_05','Axial flow fans',#10916,$,$); +#10918=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_09','Bifurcated fans',#10916,$,$); +#10919=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_12','Centrifugal fans',#10916,$,$); +#10920=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_23','Domestic fan units',#10916,$,$); +#10921=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_24','Domestic multipoint fan units',#10916,$,$); +#10922=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_44','Jet fans',#10916,$,$); +#10923=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_52','Mixed flow fans',#10916,$,$); +#10924=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_62','Plug fans',#10916,$,$); +#10925=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_64','Powered smoke and heat exhaust ventilators',#10916,$,$); +#10926=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_67','Propeller fans',#10916,$,$); +#10927=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_72','Roof mounted fans',#10916,$,$); +#10928=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_80','Smoke extract fans',#10916,$,$); +#10929=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_88','Twin axial fans',#10916,$,$); +#10930=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_89','Twin centrifugal fans',#10916,$,$); +#10931=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_29_96','Whole dwelling fan units',#10916,$,$); +#10932=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_39','Humidifiers and dehumidifiers',#10897,$,$); +#10933=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_39_22','Desiccant dehumidifiers',#10932,$,$); +#10934=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_39_28','Evaporative humidifiers',#10932,$,$); +#10935=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_39_37','Heat pump dehumidifiers',#10932,$,$); +#10936=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_39_84','Steam humidifiers',#10932,$,$); +#10937=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_39_96','Water atomizing humidifiers',#10932,$,$); +#10938=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_46','Laboratory gas products',#10897,$,$); +#10939=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_46_56','Nitrogen receivers',#10938,$,$); +#10940=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_78','Sound attenuators',#10897,$,$); +#10941=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_78_02','Acoustic duct linings',#10940,$,$); +#10942=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_78_05','Air transfer and cross talk attenuators',#10940,$,$); +#10943=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_78_07','Attenuated openings',#10940,$,$); +#10944=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_78_12','Circular attenuators',#10940,$,$); +#10945=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_78_72','Rectangular attenuators',#10940,$,$); +#10946=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_94','Vehicle exhaust distribution products',#10897,$,$); +#10947=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_94_25','Ducted rail tracks',#10946,$,$); +#10948=IFCCLASSIFICATIONREFERENCE($,'Pr_65_67_94_76','Self-sealing floor plates',#10946,$,$); +#10949=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70','Cables, conductors and fittings products',#10238,$,$); +#10950=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11','Cable management and accessories',#10949,$,$); +#10951=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_02','Cable assemblies',#10950,$,$); +#10952=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_09','Buried conduit',#10950,$,$); +#10953=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_10','Cable brackets',#10950,$,$); +#10954=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_11','Cable bands',#10950,$,$); +#10955=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_12','Cable baskets',#10950,$,$); +#10956=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_13','Cable cleats',#10950,$,$); +#10957=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_14','Cable ladders',#10950,$,$); +#10958=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_15','Cable ties',#10950,$,$); +#10959=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_16','Cable troughs',#10950,$,$); +#10960=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_17','Cable trays',#10950,$,$); +#10961=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_18','Cable trunking',#10950,$,$); +#10962=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_19','Channel cable supports',#10950,$,$); +#10963=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_20','Conduit fittings',#10950,$,$); +#10964=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_25','Duct banks',#10950,$,$); +#10965=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_29','Flexible electrical cable carriers',#10950,$,$); +#10966=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_30','Flexible conduit',#10950,$,$); +#10967=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_31','Floor cable trunking and ducting',#10950,$,$); +#10968=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_34','Cable glands',#10950,$,$); +#10969=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_41','Insulating cable trays',#10950,$,$); +#10970=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_47','Lighting busbar trunking',#10950,$,$); +#10971=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_61','Perimeter trunking',#10950,$,$); +#10972=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_62','Plastic ducts for buried electric cables',#10950,$,$); +#10973=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_63','Pliable conduit',#10950,$,$); +#10974=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_64','Points heating harnesses',#10950,$,$); +#10975=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_65','Polyvinyl chloride (PVC) trunking',#10950,$,$); +#10976=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_70','Raised access floor service outlets',#10950,$,$); +#10977=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_71','Rigid conduit',#10950,$,$); +#10978=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_75','Service outlet boxes',#10950,$,$); +#10979=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_76','Service outlet poles',#10950,$,$); +#10980=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_79','Slotted cable trunking',#10950,$,$); +#10981=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_11_80','Slotted insulating cable trays',#10950,$,$); +#10982=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_12','Cable protection products',#10949,$,$); +#10983=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_12_04','Anti-vandal cable guards',#10982,$,$); +#10984=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_12_11','Cable capping',#10982,$,$); +#10985=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_12_92','Underground concrete cable protection covers',#10982,$,$); +#10986=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_12_94','Underground plastics cable protection covers',#10982,$,$); +#10987=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_13','Cathodic protection products',#10949,$,$); +#10988=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_13_08','Bulk anodes',#10987,$,$); +#10989=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_13_50','Mesh anodes',#10987,$,$); +#10990=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_13_72','Rod anodes',#10987,$,$); +#10991=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_13_85','Sheet anodes',#10987,$,$); +#10992=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15','Communications cables and accessories',#10949,$,$); +#10993=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_03','Armoured coaxial communications cables',#10992,$,$); +#10994=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_04','Armoured communications cables',#10992,$,$); +#10995=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_06','Balanced twisted-pair cables',#10992,$,$); +#10996=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_13','Coaxial cables',#10992,$,$); +#10997=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_15','Copper cable connectors',#10992,$,$); +#10998=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_16','Copper cable terminations',#10992,$,$); +#10999=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_17','Copper voice cables',#10992,$,$); +#11000=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_18','Copper voice (LSF) cables',#10992,$,$); +#11001=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_32','Functional earth cables',#10992,$,$); +#11002=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_50','Microphone cables',#10992,$,$); +#11003=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_53','Multicore alarm cables',#10992,$,$); +#11004=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_58','Optical fibre cables',#10992,$,$); +#11005=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_59','Optical fibre cable connectors',#10992,$,$); +#11006=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_60','Optical fibre patch cords',#10992,$,$); +#11007=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_62','Optical fibre splice boxes',#10992,$,$); +#11008=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_63','Optical fibre cable terminations',#10992,$,$); +#11009=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_70','Radio frequency (RF) transmission cables',#10992,$,$); +#11010=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_80','Speaker cables',#10992,$,$); +#11011=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_15_96','Work area and patch cord cables',#10992,$,$); +#11012=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_16','Conductor rail ancillaries',#10949,$,$); +#11013=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_16_03','Anchor struts',#11012,$,$); +#11014=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_16_08','Composite insulators',#11012,$,$); +#11015=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_16_10','Conductor rail anchors',#11012,$,$); +#11016=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_16_12','Conductor rail cover boards',#11012,$,$); +#11017=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_16_15','Conductor rail guard boards',#11012,$,$); +#11018=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_16_16','Conductor rail insulators',#11012,$,$); +#11019=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_16_17','Conductor rail side ramps',#11012,$,$); +#11020=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_16_20','Conductor rail supports',#11012,$,$); +#11021=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_16_28','Eutectic strips',#11012,$,$); +#11022=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_16_34','Glass reinforced nylon insulators',#11012,$,$); +#11023=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_16_57','Nylon insulators',#11012,$,$); +#11024=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_36','High voltage cables',#10949,$,$); +#11025=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_36_34','High voltage cold shrink cable joints',#11024,$,$); +#11026=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_36_35','High voltage extruded insulation cable terminations',#11024,$,$); +#11027=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_36_36','High voltage paper insulated cable terminations',#11024,$,$); +#11028=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_36_37','High voltage power cables with extruded insulation',#11024,$,$); +#11029=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_36_38','High voltage power cables with low smoke thermosetting insulation',#11024,$,$); +#11030=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_36_39','High voltage power cables with impregnated paper insulation lead alloy sheath',#11024,$,$); +#11031=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_36_40','High voltage power cables with thermosetting insulation',#11024,$,$); +#11032=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_42','Insulators',#10949,$,$); +#11033=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_42_26','Deadend insulators',#11032,$,$); +#11034=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_42_36','High voltage pin insulators',#11032,$,$); +#11035=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_42_46','Line post insulators',#11032,$,$); +#11036=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_42_47','Longrod insulators',#11032,$,$); +#11037=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_42_48','Low voltage pin insulators',#11032,$,$); +#11038=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_42_77','Shackle insulators',#11032,$,$); +#11039=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_42_82','Spool insulators',#11032,$,$); +#11040=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_42_83','Station post insulators',#11032,$,$); +#11041=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_42_84','Stay insulators',#11032,$,$); +#11042=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_42_85','Strain insulators',#11032,$,$); +#11043=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_42_86','Suspension insulators',#11032,$,$); +#11044=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46','Lightning protection and earthing components',#10949,$,$); +#11045=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_01','Air terminals',#11044,$,$); +#11046=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_03','Aluminium earth tapes',#11044,$,$); +#11047=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_04','Aluminium rod lightning conductors',#11044,$,$); +#11048=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_14','Copper earth tapes',#11044,$,$); +#11049=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_15','Copper solid circular lightning conductors',#11044,$,$); +#11050=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_24','Earth bars',#11044,$,$); +#11051=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_25','Earth plates',#11044,$,$); +#11052=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_26','Earth rod inspection pits',#11044,$,$); +#11053=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_27','Earth rods',#11044,$,$); +#11054=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_29','Earthing clamps',#11044,$,$); +#11055=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_30','Earthing conductors',#11044,$,$); +#11056=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_32','Flexible braids',#11044,$,$); +#11057=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_46','Lightning protection conductor clamps',#11044,$,$); +#11058=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_47','Lightning protection conductor metallic direct contact clips',#11044,$,$); +#11059=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_48','Lightning protection conductor non-metallic direct contact clips',#11044,$,$); +#11060=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_46_80','Soil conditioning conductive agents',#11044,$,$); +#11061=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48','Low voltage cables',#10949,$,$); +#11062=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_13','Crosslinked EVA insulated single core non-sheathed cables',#11061,$,$); +#11063=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_14','Crosslinked silicone rubber insulated single core cables',#11061,$,$); +#11064=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_29','Fire resistant screened (LSHF) cables',#11061,$,$); +#11065=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_31','Flexible cables with crosslinked elastomeric insulation',#11061,$,$); +#11066=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_32','Flexible cables with thermoplastic PVC insulation',#11061,$,$); +#11067=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_37','Heat resistant single-core non-sheathed cross-linked elastomeric insulated cables',#11061,$,$); +#11068=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_38','Heavy-duty cross-linked elastomeric insulated and sheathed flexible cables',#11061,$,$); +#11069=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_39','Heavy-duty heat resistant cross-linked elastomeric insulated and sheathed flexible cables',#11061,$,$); +#11070=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_40','Heavy-duty heat resistant LSHF insulated and sheathed flexible cables',#11061,$,$); +#11071=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_41','Heavy-duty mineral insulated cables',#11061,$,$); +#11072=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_46','Light duty heat resistant PVC insulated and sheathed flexible cables',#11061,$,$); +#11073=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_48','Light duty mineral insulated cables',#11061,$,$); +#11074=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_49','Light duty PVC insulated and sheathed flexible cables',#11061,$,$); +#11075=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_50','Low voltage cold shrink cable joints',#11061,$,$); +#11076=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_51','Mineral insulation cables',#11061,$,$); +#11077=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_55','Multicore screened thermosetting insulated (LSHF) sheathed cables',#11061,$,$); +#11078=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_56','Ordinary duty cross-linked elastomeric insulated and sheathed flexible cables',#11061,$,$); +#11079=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_57','Ordinary duty heat resistant cross-linked elastomeric insulated and sheathed flexible cables',#11061,$,$); +#11080=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_58','Ordinary duty heat resistant PVC insulated and sheathed flexible cables',#11061,$,$); +#11081=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_59','Ordinary duty low temperature PVC insulated and sheathed flexible cables',#11061,$,$); +#11082=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_60','Ordinary duty PVC insulated and sheathed flexible cables',#11061,$,$); +#11083=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_61','PVC insulated and sheathed cables',#11061,$,$); +#11084=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_62','PVC insulated flexible single core cables for switchgear and controlgear wiring',#11061,$,$); +#11085=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_63','PVC insulated single core non-sheathed cables',#11061,$,$); +#11086=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_73','Single core heavy-duty cross-linked insulated and sheathed flexible (LSHF) cables',#11061,$,$); +#11087=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_74','Single core heat resistant non-sheathed thermoplastic PVC insulated cables',#11061,$,$); +#11088=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_75','Single core non-sheathed (LHSF) insulated cables',#11061,$,$); +#11089=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_77','Single core PVC insulated cables',#11061,$,$); +#11090=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_79','Split concentric PVC insulated and sheathed cables',#11061,$,$); +#11091=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_88','Thermosetting insulated armoured fire resistant (LSHF) cables',#11061,$,$); +#11092=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_89','Thermosetting insulated and PVC sheathed armoured cables',#11061,$,$); +#11093=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_90','Thermosetting insulated and thermoplastic sheathed (LSHF) armoured cables',#11061,$,$); +#11094=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_91','Thermosetting insulated and thermoplastic sheathed (LSHF) cables',#11061,$,$); +#11095=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_92','Thermosetting insulated non armoured PVC sheathed cables',#11061,$,$); +#11096=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_93','Thermosetting insulated (XLPE), thermoplastic low smoke zero halogen (LSZH) sheathed cables',#11061,$,$); +#11097=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_94','Thermosetting insulated, non-armoured, fire-resistant, single core non-sheathed cables',#11061,$,$); +#11098=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_48_95','Thermosetting insulated single core fire resistant non-armoured non-sheathed cables',#11061,$,$); +#11099=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_50','Low voltage prefabricated cables',#10949,$,$); +#11100=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_50_15','Connection cables',#11099,$,$); +#11101=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_50_22','Distribution connectors',#11099,$,$); +#11102=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_50_28','Extender cables',#11099,$,$); +#11103=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_50_37','Home run cables',#11099,$,$); +#11104=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_50_47','Lighting extender leads',#11099,$,$); +#11105=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_50_49','Luminaire connection cables',#11099,$,$); +#11106=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_50_64','Prefabricated low smoke zero halogen (LSZH) insulated and sheathed multi-core cables',#11099,$,$); +#11107=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_50_66','Prefabricated low smoke zero halogen (LSZH) insulated single cables in flexible conduit',#11099,$,$); +#11108=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_50_72','RJ45 cables',#11099,$,$); +#11109=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_50_84','Starter leads',#11099,$,$); +#11110=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_50_86','Switch connection leads',#11099,$,$); +#11111=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_50_88','T connectors',#11099,$,$); +#11112=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_70','Railway rolling stock cables',#10949,$,$); +#11113=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_70_53','Multicore, cross-linked elastomeric-insulated, reduced dimensions, special fire performance cables',#11112,$,$); +#11114=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_70_55','Multicore, cross-linked elastomeric-insulated, special fire performance cables',#11112,$,$); +#11115=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_70_57','Multicore and multi-pair, thin wall-insulated, special fire performance cables',#11112,$,$); +#11116=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_70_83','Screened, multicore, cross-linked elastomeric-insulated, reduced dimensions, special fire performance cables',#11112,$,$); +#11117=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_70_85','Single core, cross-linked elastomeric-insulated, reduced dimensions, special fire performance cables',#11112,$,$); +#11118=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_70_87','Single core, cross-linked elastomeric-insulated, 600/1000 V, special fire performance cables',#11112,$,$); +#11119=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_70_88','Single core, cross-linked elastomeric-insulated, 1.8/3 kV, special fire performance cables',#11112,$,$); +#11120=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_70_89','Single core, silicone rubber-insulated, high-temperature, special fire performance cables',#11112,$,$); +#11121=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_70_91','Single core, thin wall-insulated, special fire performance cables',#11112,$,$); +#11122=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80','Signalling cables',#10949,$,$); +#11123=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_01','2 core unscreened 1000 V (LSF) cables',#11122,$,$); +#11124=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_03','Abrasion resistant single core triple insulated (LSF) signalling equipment room cables',#11122,$,$); +#11125=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_14','Concentric screened cables with screens separate',#11122,$,$); +#11126=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_16','Concentric screened (LSF) cables with screens separate',#11122,$,$); +#11127=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_46','Multicore concentric screened (LSF) track crossing cables with screens in contact',#11122,$,$); +#11128=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_47','Multicore concentric screened track crossing cables with screens in contact',#11122,$,$); +#11129=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_49','Multicore concentric screened track crossing cables with screens separate',#11122,$,$); +#11130=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_51','Multicore screened (LSF) cable run cables',#11122,$,$); +#11131=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_52','Multicore screened (LSF) track crossing cables',#11122,$,$); +#11132=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_53','Multicore screened pair (LSF) axle counter cables',#11122,$,$); +#11133=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_55','Multi-pair screened (LSF) cables with each pair screened',#11122,$,$); +#11134=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_74','Single core double insulated inductive loop track cables',#11122,$,$); +#11135=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_75','Single core double insulated (LSF) 600 V cables',#11122,$,$); +#11136=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_76','Single core double insulated (LSF) 600 V track crossing cables',#11122,$,$); +#11137=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_78','Single core double insulated (LSF) signalling equipment room cables',#11122,$,$); +#11138=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_79','Single core double insulated (LSF) track crossing cables',#11122,$,$); +#11139=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_81','Single core (LSF) cables',#11122,$,$); +#11140=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_83','Single core screened pair axle counter cables',#11122,$,$); +#11141=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_87','Triaxial concentric cables',#11122,$,$); +#11142=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_88','Triaxial concentric (LSF) cables',#11122,$,$); +#11143=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_90','Twisted pair screened (LSF) cable run cables',#11122,$,$); +#11144=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_91','Twisted pair screened (LSF) signalling equipment room cables',#11122,$,$); +#11145=IFCCLASSIFICATIONREFERENCE($,'Pr_65_70_80_92','Twisted pair screened (LSF) track crossing cables',#11122,$,$); +#11146=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72','Electrical power products and wiring accessories',#10238,$,$); +#11147=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27','Electrical protective devices',#11146,$,$); +#11148=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_02','Air circuit breakers',#11147,$,$); +#11149=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_11','Cartridge fuses',#11147,$,$); +#11150=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_23','Direct current (d.c.) surge protection devices',#11147,$,$); +#11151=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_26','Earth continuity monitors',#11147,$,$); +#11152=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_32','Fuse links',#11147,$,$); +#11153=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_34','Fuse lock-off devices',#11147,$,$); +#11154=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_42','Isolation transformers',#11147,$,$); +#11155=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_44','J-type feeder pillar fuses',#11147,$,$); +#11156=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_47','Low-voltage fuse links',#11147,$,$); +#11157=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_48','Low voltage power supply surge protection devices',#11147,$,$); +#11158=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_50','Mains power supply transient overvoltage suppression devices',#11147,$,$); +#11159=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_52','Miniature circuit breakers',#11147,$,$); +#11160=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_53','Moulded case circuit breakers',#11147,$,$); +#11161=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_72','Residual current circuit breakers',#11147,$,$); +#11162=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_73','Residual current circuit breakers with integral overcurrent protection',#11147,$,$); +#11163=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_74','Residual current monitors',#11147,$,$); +#11164=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_27_88','Transient overvoltage surge suppression devices',#11147,$,$); +#11165=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_43','Power conditioning equipment',#11146,$,$); +#11166=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_43_01','Active electrical filters',#11165,$,$); +#11167=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_43_05','Automatic power factor correction equipment',#11165,$,$); +#11168=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_43_07','Blocking diodes',#11165,$,$); +#11169=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_43_39','Hybrid electrical filters',#11165,$,$); +#11170=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_43_42','Inverters',#11165,$,$); +#11171=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_43_60','Passive electrical filters',#11165,$,$); +#11172=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_43_64','Power conditioning units',#11165,$,$); +#11173=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_43_71','Rectifiers',#11165,$,$); +#11174=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_43_95','Voltage optimizers',#11165,$,$); +#11175=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_43_96','Voltage transformers',#11165,$,$); +#11176=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_59','Overhead power supply line products',#11146,$,$); +#11177=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_59_06','Balance weight anchor tensioning devices',#11176,$,$); +#11178=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_59_80','Spring tensioning devices',#11176,$,$); +#11179=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_59_90','Turnbuckle tensioning devices',#11176,$,$); +#11180=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_60','Overhead power supply line support products',#11146,$,$); +#11181=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_60_23','Double insulator catenary cantilever assemblies',#11180,$,$); +#11182=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_60_24','Double insulator trolley wire cantilever assemblies',#11180,$,$); +#11183=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_60_55','Overhead line cable supports',#11180,$,$); +#11184=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_60_56','Overhead line catenary wires',#11180,$,$); +#11185=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_60_57','Overhead line contact wires',#11180,$,$); +#11186=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_60_58','Overhead line droppers',#11180,$,$); +#11187=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_60_59','Overhead line fixings',#11180,$,$); +#11188=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_60_60','Overhead line mounting structures',#11180,$,$); +#11189=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_60_61','Overhead line span wires',#11180,$,$); +#11190=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_60_63','Overhead wiring splices',#11180,$,$); +#11191=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_60_77','Single insulator catenary cantilever assemblies',#11180,$,$); +#11192=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_60_78','Single insulator trolley wire cantilever assemblies',#11180,$,$); +#11193=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97','Wiring accessories',#11146,$,$); +#11194=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_03','Architrave switches',#11193,$,$); +#11195=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_06','Bayonet lamp holders',#11193,$,$); +#11196=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_11','Cable couplers',#11193,$,$); +#11197=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_12','Cable outlet plates',#11193,$,$); +#11198=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_16','Ceiling light switches',#11193,$,$); +#11199=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_17','Ceiling power switches',#11193,$,$); +#11200=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_18','Ceiling roses',#11193,$,$); +#11201=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_20','Cooker control units',#11193,$,$); +#11202=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_21','Cooker connection units',#11193,$,$); +#11203=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_22','Dimmer switches and controls',#11193,$,$); +#11204=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_23','Double pole switches',#11193,$,$); +#11205=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_26','Edison screw lamp holders',#11193,$,$); +#11206=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_27','Electrical connection boxes',#11193,$,$); +#11207=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_28','End brackets',#11193,$,$); +#11208=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_29','Electric vehicle charging points',#11193,$,$); +#11209=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_30','Fan isolators',#11193,$,$); +#11210=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_31','Fused connection units',#11193,$,$); +#11211=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_34','Grid switches',#11193,$,$); +#11212=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_40','Industrial plugs',#11193,$,$); +#11213=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_41','Industrial socket outlets',#11193,$,$); +#11214=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_47','Luminaire supporting couplers',#11193,$,$); +#11215=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_52','Multi-gang power outlets',#11193,$,$); +#11216=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_63','Plate switches',#11193,$,$); +#11217=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_66','Prefabricated wiring switches',#11193,$,$); +#11218=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_72','Round pin socket outlets',#11193,$,$); +#11219=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_75','Safety pendant lamp holders',#11193,$,$); +#11220=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_76','Safety pendant sets',#11193,$,$); +#11221=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_78','Shaver supply units',#11193,$,$); +#11222=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_79','Single voltage shaver outlets',#11193,$,$); +#11223=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_81','Socket outlet residual current devices (SRCD)',#11193,$,$); +#11224=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_82','Specialist socket outlets',#11193,$,$); +#11225=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_83','Surface and concealed wiring enclosures',#11193,$,$); +#11226=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_84','Standard socket outlets',#11193,$,$); +#11227=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_85','Stud terminal covers',#11193,$,$); +#11228=IFCCLASSIFICATIONREFERENCE($,'Pr_65_72_97_86','Stud terminals',#11193,$,$); +#11229=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80','Transport distribution products',#10238,$,$); +#11230=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_06','Baggage handling conveyors',#11229,$,$); +#11231=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15','Cranes and lifting products',#11229,$,$); +#11232=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15_09','Cable slot channels',#11231,$,$); +#11233=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15_11','Cable slot covers',#11231,$,$); +#11234=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15_13','Cable turnover pits',#11231,$,$); +#11235=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15_16','Crane arrestors',#11231,$,$); +#11236=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15_18','Crane stow pin sockets',#11231,$,$); +#11237=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15_22','Detachable hooks',#11231,$,$); +#11238=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15_47','Lifting rings',#11231,$,$); +#11239=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15_48','Lifting trunnions',#11231,$,$); +#11240=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15_59','Overhead travelling cranes',#11231,$,$); +#11241=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15_71','Roof trolleys',#11231,$,$); +#11242=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15_73','Runway tracks',#11231,$,$); +#11243=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15_74','Runway trolleys',#11231,$,$); +#11244=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_15_88','Tie down slots',#11231,$,$); +#11245=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_23','Dock levellers',#11229,$,$); +#11246=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_23_06','Bascule dock bridges',#11245,$,$); +#11247=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_23_38','Hydraulic hinged-lip dock levellers',#11245,$,$); +#11248=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_23_39','Hydraulic telescopic-lip dock levellers',#11245,$,$); +#11249=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_23_51','Mechanical dock levellers',#11245,$,$); +#11250=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28','Escalator and moving walk products',#11229,$,$); +#11251=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_04','Escalator and moving walk auxiliary brakes',#11250,$,$); +#11252=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_06','Escalator and moving walk balustrades',#11250,$,$); +#11253=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_07','Escalator and moving walk balustrade newels',#11250,$,$); +#11254=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_09','Escalator and moving walk belts',#11250,$,$); +#11255=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_12','Escalator and moving walk cladding',#11250,$,$); +#11256=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_14','Escalator combs',#11250,$,$); +#11257=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_16','Escalator comb plates',#11250,$,$); +#11258=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_21','Escalators',#11250,$,$); +#11259=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_22','Escalator and moving walk decking',#11250,$,$); +#11260=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_24','Escalator and moving walk drive units',#11250,$,$); +#11261=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_36','Escalator and moving walk handrails',#11250,$,$); +#11262=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_38','Escalator hand winding devices',#11250,$,$); +#11263=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_41','Escalator and moving walk inspection covers',#11250,$,$); +#11264=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_46','Escalator and moving walk landing floor plates',#11250,$,$); +#11265=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_52','Moving walks',#11250,$,$); +#11266=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_58','Escalator and moving walk operational brakes',#11250,$,$); +#11267=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_60','Escalator pallets',#11250,$,$); +#11268=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_78','Escalator and moving walk skirtings',#11250,$,$); +#11269=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_80','Escalator and moving walk skirt deflectors',#11250,$,$); +#11270=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_84','Escalator step treads',#11250,$,$); +#11271=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_89','Moving walk treadway belts',#11250,$,$); +#11272=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_28_90','Moving walk treadway pallets',#11250,$,$); +#11273=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_42','Inclined transport cars, platforms and chairs',#11229,$,$); +#11274=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_42_11','Cable cars',#11273,$,$); +#11275=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_42_37','Homelifts',#11273,$,$); +#11276=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_42_39','Inclined chairlifts',#11273,$,$); +#11277=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_42_42','Inclined standing platforms',#11273,$,$); +#11278=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_42_43','Inclined wheelchair platforms',#11273,$,$); +#11279=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_42_77','Ski lift chairs',#11273,$,$); +#11280=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_42_84','Stairlift trolleys',#11273,$,$); +#11281=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_46','Laundry conveyors',#11229,$,$); +#11282=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_46_15','Laundry and garment conveyors',#11281,$,$); +#11283=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_46_42','Inclined loading laundry conveyors',#11281,$,$); +#11284=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_46_77','Shuttle lifting laundry conveyors',#11281,$,$); +#11285=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_47','Lifting platforms and hoists',#11229,$,$); +#11286=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_47_04','Assisted transfer hoists',#11285,$,$); +#11287=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_47_12','Ceiling track hoists',#11285,$,$); +#11288=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_47_31','Fixed hoists',#11285,$,$); +#11289=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_47_47','Moveable hoists',#11285,$,$); +#11290=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_47_64','Poolside hoists',#11285,$,$); +#11291=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_47_76','Service hoists',#11285,$,$); +#11292=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_47_84','Step lifts',#11285,$,$); +#11293=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_47_94','Vehicle hoists',#11285,$,$); +#11294=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_47_95','Vertical lifting platforms',#11285,$,$); +#11295=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_47_96','Vertical storage lifts',#11285,$,$); +#11296=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_65','Pneumatic document conveying products',#11229,$,$); +#11297=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_65_63','Pneumatic document conveying blowers',#11296,$,$); +#11298=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_65_64','Pneumatic document conveying carriers',#11296,$,$); +#11299=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_65_65','Pneumatic document conveying diverters',#11296,$,$); +#11300=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_65_66','Pneumatic document conveying pipes and fittings',#11296,$,$); +#11301=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_65_67','Pneumatic document conveying stations',#11296,$,$); +#11302=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_89','Transport cables',#11229,$,$); +#11303=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_89_11','Cable car cables',#11302,$,$); +#11304=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_89_46','Lift cables',#11302,$,$); +#11305=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_89_85','Ski lift cables',#11302,$,$); +#11306=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_96','Wastewater conveyor products',#11229,$,$); +#11307=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_96_07','Belt conveyors',#11306,$,$); +#11308=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_96_24','Drag or chain link conveyors',#11306,$,$); +#11309=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_96_76','Screw conveyors',#11306,$,$); +#11310=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_96_79','Shafted screw conveyors',#11306,$,$); +#11311=IFCCLASSIFICATIONREFERENCE($,'Pr_65_80_96_80','Shaftless spiral conveyors',#11306,$,$); +#11312=IFCCLASSIFICATIONREFERENCE($,'Pr_70','Services outlet products',#4923,$,$); +#11313=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50','Solid waste disposal products',#11312,$,$); +#11314=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_71','Refuse disposal equipment',#11313,$,$); +#11315=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_71_18','Crushers',#11314,$,$); +#11316=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_71_42','Incinerators',#11314,$,$); +#11317=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_71_60','Packagers',#11314,$,$); +#11318=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_80','Solid waste balers',#11313,$,$); +#11319=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_80_37','Horizontal balers',#11318,$,$); +#11320=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_80_94','Vertical balers',#11318,$,$); +#11321=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_85','Solid waste compactor products',#11313,$,$); +#11322=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_85_24','Dry waste compactors',#11321,$,$); +#11323=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_85_37','High density compaction extruders',#11321,$,$); +#11324=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_85_65','Portable waste compactors',#11321,$,$); +#11325=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_85_66','Portable waste compactor and bin lifts',#11321,$,$); +#11326=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_85_78','Skip portable waste compactors',#11321,$,$); +#11327=IFCCLASSIFICATIONREFERENCE($,'Pr_70_50_85_96','Wet waste compactors',#11321,$,$); +#11328=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55','Liquid and gas outlet products',#11312,$,$); +#11329=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_33','Gas and foam nozzles and sprinklers',#11328,$,$); +#11330=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_33_11','Carbon dioxide fire extinguishing nozzles',#11329,$,$); +#11331=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_33_28','Foam firefighting monitors',#11329,$,$); +#11332=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_33_30','Foam sprinklers',#11329,$,$); +#11333=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_33_36','Halocarbons and inert gas fire extinguishing nozzles',#11329,$,$); +#11334=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42','Irrigation water outlets',#11328,$,$); +#11335=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_09','Bubblers',#11334,$,$); +#11336=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_11','Capillary matting',#11334,$,$); +#11337=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_22','Drippers',#11334,$,$); +#11338=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_46','Lateral pipelines',#11334,$,$); +#11339=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_47','Layered irrigation matting',#11334,$,$); +#11340=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_52','Micro-distribution pipelines',#11334,$,$); +#11341=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_53','Micro-perforated polyethylene sheet',#11334,$,$); +#11342=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_54','Misters',#11334,$,$); +#11343=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_58','Oscillating sprinklers',#11334,$,$); +#11344=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_64','Porous pipelines',#11334,$,$); +#11345=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_70','Rain guns',#11334,$,$); +#11346=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_73','Rotary impact sprinklers',#11334,$,$); +#11347=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_80','Spray jets',#11334,$,$); +#11348=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_42_90','Tree irrigation rings',#11334,$,$); +#11349=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_51','Medical gases outlets',#11328,$,$); +#11350=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_51_30','Flexible pendants',#11349,$,$); +#11351=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_51_37','Headwall bedhead units',#11349,$,$); +#11352=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_51_52','Terminal units',#11349,$,$); +#11353=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_51_53','Medical trunking bedhead units',#11349,$,$); +#11354=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_51_55','Multi-movement pendants',#11349,$,$); +#11355=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_51_73','Retractable pendants',#11349,$,$); +#11356=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_51_74','Rigid pendants',#11349,$,$); +#11357=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_58','Oil and grease lubricant supply products',#11328,$,$); +#11358=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_58_34','Greases',#11357,$,$); +#11359=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_58_48','Lubricator height adjustors',#11357,$,$); +#11360=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_58_58','Oils',#11357,$,$); +#11361=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_58_68','Rail friction modifier',#11357,$,$); +#11362=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_58_70','Rail lubricators',#11357,$,$); +#11363=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_58_72','Rail traction gels',#11357,$,$); +#11364=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_58_80','Solid lubricants',#11357,$,$); +#11365=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_62','Phase change outlet products',#11328,$,$); +#11366=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_62_27','Foam chambers',#11365,$,$); +#11367=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_62_29','Foam generators',#11365,$,$); +#11368=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_62_31','Foam proportioners',#11365,$,$); +#11369=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_76','Sewage treatment plant',#11328,$,$); +#11370=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_76_34','Geocellular modular plastics storage units',#11369,$,$); +#11371=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_76_62','Private packaged pumping stations',#11369,$,$); +#11372=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_76_64','Private packaged septic tank units',#11369,$,$); +#11373=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_76_66','Private packaged sewage treatment units',#11369,$,$); +#11374=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_76_72','Reed bed units',#11369,$,$); +#11375=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_76_76','Sewage below-ground storage tanks (cesspools)',#11369,$,$); +#11376=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_96','Waste water outlets and plugs',#11328,$,$); +#11377=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_96_06','Bath wastes',#11376,$,$); +#11378=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_96_09','Bidet wastes',#11376,$,$); +#11379=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_96_76','Scrub up trough and wash trough wastes',#11376,$,$); +#11380=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_96_83','Shower tray wastes',#11376,$,$); +#11381=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_96_84','Sink wastes',#11376,$,$); +#11382=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_96_93','Urinal wastes',#11376,$,$); +#11383=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_96_97','Wash basins wastes',#11376,$,$); +#11384=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_96_98','Waste water plugs and chains',#11376,$,$); +#11385=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_97','Water fire extinguishing outlets',#11328,$,$); +#11386=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_97_01','Above-ground fire hydrants',#11385,$,$); +#11387=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_97_23','Domestic sprinkler heads',#11385,$,$); +#11388=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_97_37','High velocity nozzles',#11385,$,$); +#11389=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_97_51','Medium velocity nozzles',#11385,$,$); +#11390=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_97_57','Nozzles',#11385,$,$); +#11391=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_97_84','Sprinkler heads',#11385,$,$); +#11392=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_97_93','Underground fire hydrants',#11385,$,$); +#11393=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_97_96','Water firefighting monitors',#11385,$,$); +#11394=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98','Water inlets and outlets',#11328,$,$); +#11395=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_30','Fountains',#11394,$,$); +#11396=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_35','Green roof drainage outlets',#11394,$,$); +#11397=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_37','High-pressure water hose connectors',#11394,$,$); +#11398=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_46','Laminar jets',#11394,$,$); +#11399=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_59','Overflows',#11394,$,$); +#11400=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_60','Passive tank outlets',#11394,$,$); +#11401=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_65','Pool water inlets',#11394,$,$); +#11402=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_66','Pool water outlets',#11394,$,$); +#11403=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_84','Sprinklers',#11394,$,$); +#11404=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_87','Tape lines and drippers',#11394,$,$); +#11405=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_92','Ultrasonic mist makers',#11394,$,$); +#11406=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_94','Washout hydrants',#11394,$,$); +#11407=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_95','Waterfalls and cascades',#11394,$,$); +#11408=IFCCLASSIFICATIONREFERENCE($,'Pr_70_55_98_96','Water feature nozzles',#11394,$,$); +#11409=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60','Space heating and cooling products',#11312,$,$); +#11410=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_14','Climatic beams and ceilings',#11409,$,$); +#11411=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_14_02','Active climatic beams',#11410,$,$); +#11412=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_14_10','Bulkhead active climatic beams',#11410,$,$); +#11413=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_14_14','Climatic ceiling panels',#11410,$,$); +#11414=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_14_47','Linear active climatic beams',#11410,$,$); +#11415=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_14_53','Modular or cassette active climatic beams',#11410,$,$); +#11416=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_14_55','Multi-service climatic beams',#11410,$,$); +#11417=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_14_60','Passive climatic beams',#11410,$,$); +#11418=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36','Heat emitters',#11409,$,$); +#11419=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_02','Air curtains',#11418,$,$); +#11420=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_06','Cabinet direct heaters',#11418,$,$); +#11421=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_08','Cabinet indirect heaters',#11418,$,$); +#11422=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_15','Constant wattage trace heating cables',#11418,$,$); +#11423=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_22','Decorative fuel effect gas fires',#11418,$,$); +#11424=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_26','Electric heated towel rails',#11418,$,$); +#11425=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_27','Electric cable underfloor heating elements',#11418,$,$); +#11426=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_28','Electric sheet underfloor heating elements',#11418,$,$); +#11427=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_29','Equipment heaters',#11418,$,$); +#11428=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_30','Fan convectors',#11418,$,$); +#11429=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_33','Gas fired unit heaters',#11418,$,$); +#11430=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_35','Gas fires',#11418,$,$); +#11431=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_37','Heat pump driven air curtains',#11418,$,$); +#11432=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_42','Inset live fuel effect gas fires',#11418,$,$); +#11433=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_48','Low temperature hot water (LTHW) heated towel rails',#11418,$,$); +#11434=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_49','Low temperature hot water (LTHW) underfloor heating',#11418,$,$); +#11435=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_52','Mirror heaters',#11418,$,$); +#11436=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_56','Natural convectors',#11418,$,$); +#11437=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_60','Points heater cables',#11418,$,$); +#11438=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_62','Points heating kits',#11418,$,$); +#11439=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_64','Power-limiting trace heating cables',#11418,$,$); +#11440=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_70','Radiant luminous heaters',#11418,$,$); +#11441=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_71','Radiant panels',#11418,$,$); +#11442=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_72','Radiant tube heaters',#11418,$,$); +#11443=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_73','Radiators',#11418,$,$); +#11444=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_74','Room heaters',#11418,$,$); +#11445=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_76','Self-regulating trace heating cables',#11418,$,$); +#11446=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_77','Series resistance trace heating cables and tapes',#11418,$,$); +#11447=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_80','Solid fuel room heaters',#11418,$,$); +#11448=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_88','Thermal storage heaters',#11418,$,$); +#11449=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_90','Trench convectors',#11418,$,$); +#11450=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_93','Unit heaters',#11418,$,$); +#11451=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_36_97','Wood-burning stoves',#11418,$,$); +#11452=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37','Heat pumps',#11409,$,$); +#11453=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_02','Air to air heat pumps',#11452,$,$); +#11454=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_04','Air to water heat pumps',#11452,$,$); +#11455=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_08','Brine to water heat pumps',#11452,$,$); +#11456=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_25','Dual split gas engine driven heat pumps',#11452,$,$); +#11457=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_33','Gas engine driven heat pumps',#11452,$,$); +#11458=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_34','Gas fired absorption heat pumps',#11452,$,$); +#11459=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_36','Ground source heat pumps',#11452,$,$); +#11460=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_47','Low temperature air to water heat pumps',#11452,$,$); +#11461=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_50','Medium or high temperature air to water heat pumps',#11452,$,$); +#11462=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_52','Multi-split air to air heat pumps',#11452,$,$); +#11463=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_53','Multi-split gas engine driven heat pumps',#11452,$,$); +#11464=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_54','Multi-split variable refrigerant flow (VRF) water to air heat pumps',#11452,$,$); +#11465=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_78','Single split air to air heat pumps',#11452,$,$); +#11466=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_80','Single split gas engine driven heat pumps',#11452,$,$); +#11467=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_82','Single split water to air heat pumps',#11452,$,$); +#11468=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_94','Variable refrigerant flow (VRF) air to air heat pumps',#11452,$,$); +#11469=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_95','Variable refrigerant flow (VRF) gas engine driven heat pumps',#11452,$,$); +#11470=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_96','Water to air heat pumps',#11452,$,$); +#11471=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_37_98','Water to water heat pumps',#11452,$,$); +#11472=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_60','Pavement heating products',#11409,$,$); +#11473=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_60_37','Pavement heating cables',#11472,$,$); +#11474=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_60_38','Pavement heating mats',#11472,$,$); +#11475=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_82','Space heating fittings and equipment',#11409,$,$); +#11476=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_82_29','Fenders',#11475,$,$); +#11477=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_82_30','Fireplace hearths',#11475,$,$); +#11478=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_82_31','Fireplace hoods',#11475,$,$); +#11479=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_82_32','Fireplace surrounds',#11475,$,$); +#11480=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_82_41','Inset open fireplace firebacks',#11475,$,$); +#11481=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_82_42','Inset open fireplace surrounds and hearths',#11475,$,$); +#11482=IFCCLASSIFICATIONREFERENCE($,'Pr_70_60_82_43','Inset open fires',#11475,$,$); +#11483=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65','Air and fume outlet products',#11312,$,$); +#11484=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03','Air conditioning units',#11483,$,$); +#11485=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03_01','Adiabatic coolers',#11484,$,$); +#11486=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03_02','Air cooled condensing units',#11484,$,$); +#11487=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03_25','Dry air coolers',#11484,$,$); +#11488=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03_27','Evaporative cooling units',#11484,$,$); +#11489=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03_29','Fan coil units',#11484,$,$); +#11490=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03_41','Indirect evaporative cooling units',#11484,$,$); +#11491=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03_42','Indoor refrigeration units',#11484,$,$); +#11492=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03_43','Induction units',#11484,$,$); +#11493=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03_47','Local air conditioning units',#11484,$,$); +#11494=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03_72','Room air conditioning units',#11484,$,$); +#11495=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03_84','Split coil remote air cooled condensing units',#11484,$,$); +#11496=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03_86','Split coil room air conditioning units',#11484,$,$); +#11497=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_03_94','Variable refrigerant flow units',#11484,$,$); +#11498=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04','Air terminals and diffusers',#11483,$,$); +#11499=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_02','Air diffusers',#11498,$,$); +#11500=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_03','Air grilles',#11498,$,$); +#11501=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_04','Air plenum boxes',#11498,$,$); +#11502=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_22','Displacement ventilation diffusers',#11498,$,$); +#11503=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_24','Domestic air diffusers and grilles',#11498,$,$); +#11504=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_25','Dual duct variable air volume (VAV) terminal units',#11498,$,$); +#11505=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_28','External wall grilles',#11498,$,$); +#11506=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_30','Floor linear air diffusers',#11498,$,$); +#11507=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_32','Floor-mounted air plenum boxes',#11498,$,$); +#11508=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_44','Jet diffusers',#11498,$,$); +#11509=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_46','Laminar flow panels',#11498,$,$); +#11510=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_48','Linear air diffusers',#11498,$,$); +#11511=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_53','Modular cassette ventilated ceilings',#11498,$,$); +#11512=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_56','Natural smoke and heat exhaust ventilators',#11498,$,$); +#11513=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_73','Roof ridge air terminals',#11498,$,$); +#11514=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_75','Roof slope air terminals',#11498,$,$); +#11515=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_76','Roof stack air terminals',#11498,$,$); +#11516=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_77','Roof ventilator cowls',#11498,$,$); +#11517=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_84','Specialist air terminals',#11498,$,$); +#11518=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_86','Swirl air diffusers',#11498,$,$); +#11519=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_88','Terminal fan units',#11498,$,$); +#11520=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_91','Variable air volume (VAV) fan assisted and heated terminal units',#11498,$,$); +#11521=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_92','Variable air volume (VAV) heated terminal units',#11498,$,$); +#11522=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_93','Variable air volume (VAV) fan assisted terminal units',#11498,$,$); +#11523=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_94','Variable air volume (VAV) terminal units',#11498,$,$); +#11524=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_04_95','Ventilated ceilings',#11498,$,$); +#11525=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_30','Flues and chimneys',#11483,$,$); +#11526=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_30_14','Clay chimney pots',#11525,$,$); +#11527=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_30_15','Clay flue liner terminals',#11525,$,$); +#11528=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_30_16','Concrete chimney pots',#11525,$,$); +#11529=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_30_30','Flue liners',#11525,$,$); +#11530=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_30_32','Fume extract discharge stacks',#11525,$,$); +#11531=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_30_51','Metal flues and chimneys',#11525,$,$); +#11532=IFCCLASSIFICATIONREFERENCE($,'Pr_70_65_30_84','Stainless steel chimney pots',#11525,$,$); +#11533=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70','Power and lighting outlet products',#11312,$,$); +#11534=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46','Lamps',#11533,$,$); +#11535=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_15','Compact fluorescent lamps',#11534,$,$); +#11536=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_24','Double capped tubular LED lamps',#11534,$,$); +#11537=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_30','Fluorescent lamps',#11534,$,$); +#11538=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_36','High pressure mercury vapour lamps',#11534,$,$); +#11539=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_37','High pressure sodium vapour lamps',#11534,$,$); +#11540=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_41','Induction lamps',#11534,$,$); +#11541=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_42','Infrared lamps',#11534,$,$); +#11542=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_44','Light-emitting diode (LED) lamps',#11534,$,$); +#11543=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_45','Low pressure sodium vapour lamps',#11534,$,$); +#11544=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_52','Metal halide lamps',#11534,$,$); +#11545=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_77','Self ballasted compact fluorescent lamps',#11534,$,$); +#11546=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_78','Self ballasted LED lamps',#11534,$,$); +#11547=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_80','Special lamps',#11534,$,$); +#11548=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_89','Tungsten filament lamps',#11534,$,$); +#11549=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_46_90','Tungsten halogen lamps',#11534,$,$); +#11550=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47','Lighting controls and lighting distribution products',#11533,$,$); +#11551=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_02','Automatic emergency lighting test panels',#11550,$,$); +#11552=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_12','Centralized lighting controllers',#11550,$,$); +#11553=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_16','Combined daylight and occupancy detectors',#11550,$,$); +#11554=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_21','Daylight sensors',#11550,$,$); +#11555=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_27','Extra low voltage lighting transformers',#11550,$,$); +#11556=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_28','Extra low voltage occupancy detectors',#11550,$,$); +#11557=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_47','Luminaire changeover relays',#11550,$,$); +#11558=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_48','Luminaire hold-off relays',#11550,$,$); +#11559=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_49','Luminaire inverter modules',#11550,$,$); +#11560=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_50','Luminaire sub-circuit relays',#11550,$,$); +#11561=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_51','Mains voltage occupancy detectors',#11550,$,$); +#11562=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_62','Photoelectric control units',#11550,$,$); +#11563=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_71','Remote infrared lighting commissioning controllers',#11550,$,$); +#11564=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_47_72','Remote infrared lighting user controllers',#11550,$,$); +#11565=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48','Luminaires, lighting track and lighting accessories',#11533,$,$); +#11566=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_02','Area floodlights',#11565,$,$); +#11567=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_13','Chandeliers',#11565,$,$); +#11568=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_15','Combined downlight and uplights',#11565,$,$); +#11569=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_16','Combined emergency luminaires',#11565,$,$); +#11570=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_23','Dedicated slave emergency luminaires',#11565,$,$); +#11571=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_24','Downlights',#11565,$,$); +#11572=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_26','Electrical low mounted way-guidance lighting module housings',#11565,$,$); +#11573=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_27','Electrical low mounted way-guidance lighting modules',#11565,$,$); +#11574=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_28','Electrical low mounted way-guidance lighting supply units',#11565,$,$); +#11575=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_29','Electronic ballasts',#11565,$,$); +#11576=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_30','Electronic starters',#11565,$,$); +#11577=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_32','Free standing luminaires',#11565,$,$); +#11578=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_35','Ground mounted luminaires',#11565,$,$); +#11579=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_36','Hazardous area luminaires',#11565,$,$); +#11580=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_45','LED light panels',#11565,$,$); +#11581=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_47','Lighting tracks',#11565,$,$); +#11582=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_48','Luminaire smoke hoods',#11565,$,$); +#11583=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_59','Optical fibre emergency luminaires',#11565,$,$); +#11584=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_62','Pendant luminaires',#11565,$,$); +#11585=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_65','Post top lanterns',#11565,$,$); +#11586=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_70','Recessed downlights',#11565,$,$); +#11587=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_71','Recessed luminaires',#11565,$,$); +#11588=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_73','Road lighting luminaires',#11565,$,$); +#11589=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_77','Self-contained emergency luminaires',#11565,$,$); +#11590=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_80','Sockets for demountable lighting',#11565,$,$); +#11591=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_82','Spot lights',#11565,$,$); +#11592=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_85','Surface luminaires',#11565,$,$); +#11593=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_86','Suspended luminaires',#11565,$,$); +#11594=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_92','Underwater luminaires',#11565,$,$); +#11595=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_48_93','Uplights',#11565,$,$); +#11596=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_70','Rail power products',#11533,$,$); +#11597=IFCCLASSIFICATIONREFERENCE($,'Pr_70_70_70_15','Conductor rail power connectors',#11596,$,$); +#11598=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75','Communications products',#11312,$,$); +#11599=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_01','Aeronautical lighting products',#11598,$,$); +#11600=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_01_01','Aeronautical ground lighting',#11599,$,$); +#11601=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_01_02','Airfield guidance signs',#11599,$,$); +#11602=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_01_03','Azimuth guidance for nose-in stand (AGNIS) lights',#11599,$,$); +#11603=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_01_13','Constant current regulators',#11599,$,$); +#11604=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_01_47','Lighting beacons',#11599,$,$); +#11605=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_01_65','Precision approach path indicators (PAPI)',#11599,$,$); +#11606=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_01_70','Runway and taxiway elevated lights',#11599,$,$); +#11607=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_01_71','Runway and taxiway inset lights',#11599,$,$); +#11608=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04','Audio, data and visual outlet plates and controllers',#11598,$,$); +#11609=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_03','Audio interface adaptors',#11608,$,$); +#11610=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_06','Balanced twisted-pair cable outlet plates',#11608,$,$); +#11611=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_25','DVI outlet plates',#11608,$,$); +#11612=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_29','Fibre optic cable outlet plates',#11608,$,$); +#11613=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_37','HDMI outlet plates',#11608,$,$); +#11614=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_42','Input and output control port expanders',#11608,$,$); +#11615=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_52','Modular jacks',#11608,$,$); +#11616=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_70','RCA outlet plates',#11608,$,$); +#11617=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_71','RJ-45 to BT plug adaptors',#11608,$,$); +#11618=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_85','SVGA outlet plates',#11608,$,$); +#11619=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_88','Telecommunications outlet plates',#11608,$,$); +#11620=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_90','Television outlet plates',#11608,$,$); +#11621=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_94','Volume controllers',#11608,$,$); +#11622=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_04_99','XLR outlet plates',#11608,$,$); +#11623=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36','Hearing and assisted listening products',#11598,$,$); +#11624=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_08','Bodypack receivers',#11623,$,$); +#11625=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_36','Headphones',#11623,$,$); +#11626=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_37','Headsets',#11623,$,$); +#11627=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_40','Induction loop amplifiers',#11623,$,$); +#11628=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_41','Induction loop pads',#11623,$,$); +#11629=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_42','Induction loop signal generators',#11623,$,$); +#11630=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_43','Induction loop transformers',#11623,$,$); +#11631=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_44','Induction neck loops',#11623,$,$); +#11632=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_45','Induction-loop monitor receivers',#11623,$,$); +#11633=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_46','Induction loop reassurance indicators',#11623,$,$); +#11634=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_47','Infrared hearing and assisted listening modulators',#11623,$,$); +#11635=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_48','Infrared hearing and assisted listening radiators',#11623,$,$); +#11636=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_50','Loudspeakers',#11623,$,$); +#11637=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_51','Loudspeaker end of line units',#11623,$,$); +#11638=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_64','Portable communicators',#11623,$,$); +#11639=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_36_84','Stethosets',#11623,$,$); +#11640=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_52','Mesh network products',#11598,$,$); +#11641=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_52_01','3G gateway modems',#11640,$,$); +#11642=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_52_42','Intelligent access points (IAPs)',#11640,$,$); +#11643=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_52_50','Mesh wireless routers',#11640,$,$); +#11644=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_52_56','Network switches',#11640,$,$); +#11645=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_52_64','Power over ethernet (POE) network switches',#11640,$,$); +#11646=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_52_88','Tilt sensor nodes',#11640,$,$); +#11647=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_52_92','USB gateway modems',#11640,$,$); +#11648=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_52_96','Wireless sensor nodes',#11640,$,$); +#11649=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_69','Radio communications products',#11598,$,$); +#11650=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_69_70','Radio base stations',#11649,$,$); +#11651=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70','Rail signals, indicators and controls',#11598,$,$); +#11652=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_03','Automatic warning signals',#11651,$,$); +#11653=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_05','Axle counters',#11651,$,$); +#11654=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_06','Banner repeater signals',#11651,$,$); +#11655=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_07','Balises',#11651,$,$); +#11656=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_14','Colour light signals',#11651,$,$); +#11657=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_41','In-cab signalling displays',#11651,$,$); +#11658=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_44','Junction indicators',#11651,$,$); +#11659=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_47','Limit of shunt signals',#11651,$,$); +#11660=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_60','Platform repeaters',#11651,$,$); +#11661=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_61','Points detection equipment',#11651,$,$); +#11662=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_62','Points converter devices',#11651,$,$); +#11663=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_63','Points operating equipment',#11651,$,$); +#11664=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_64','Position light signals',#11651,$,$); +#11665=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_65','Possession limit boards',#11651,$,$); +#11666=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_70','Rail gap indicator signals',#11651,$,$); +#11667=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_72','Route indicators',#11651,$,$); +#11668=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_76','Semaphore disc signals',#11651,$,$); +#11669=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_77','Semaphore signals',#11651,$,$); +#11670=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_78','Semaphore subsidiary signals',#11651,$,$); +#11671=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_80','Signalling relays',#11651,$,$); +#11672=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_89','Track circuits',#11651,$,$); +#11673=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_90','Train protection warning signals',#11651,$,$); +#11674=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_70_91','Treadles',#11651,$,$); +#11675=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72','Road traffic and pedestrian control signals',#11598,$,$); +#11676=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_01','Above ground vehicle detection products',#11675,$,$); +#11677=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_07','Belisha beacons',#11675,$,$); +#11678=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_22','Detector loops',#11675,$,$); +#11679=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_30','Fixed vertical road traffic signs',#11675,$,$); +#11680=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_48','Level crossing signals',#11675,$,$); +#11681=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_49','Mass detectors',#11675,$,$); +#11682=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_50','Motorway lane signals',#11675,$,$); +#11683=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_51','Motorway signal mark 1',#11675,$,$); +#11684=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_53','Motorway signal mark 3',#11675,$,$); +#11685=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_54','Motorway signal mark 4',#11675,$,$); +#11686=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_60','Pedestrian signal controllers',#11675,$,$); +#11687=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_61','Pedestrian crossing signals',#11675,$,$); +#11688=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_80','Solar powered illuminated bollards',#11675,$,$); +#11689=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_87','Traffic signal controller units',#11675,$,$); +#11690=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_89','Transilluminated traffic bollards',#11675,$,$); +#11691=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_92','Urban traffic management signs',#11675,$,$); +#11692=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_94','Variable message traffic signs',#11675,$,$); +#11693=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_95','Vehicle activated signs',#11675,$,$); +#11694=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_96','Vehicular traffic signals',#11675,$,$); +#11695=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_98','Wig wag signals',#11675,$,$); +#11696=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_72_99','Wig wag signal control units',#11675,$,$); +#11697=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_80','Sports timing and scoring equipment',#11598,$,$); +#11698=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_80_27','Electronic scoreboards',#11697,$,$); +#11699=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_80_46','Lane boxes',#11697,$,$); +#11700=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_80_48','Lane manual push buttons',#11697,$,$); +#11701=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_80_50','Manual scoreboards',#11697,$,$); +#11702=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_80_72','Relay race break sensors',#11697,$,$); +#11703=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_80_82','Swimmers starting blocks',#11697,$,$); +#11704=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_80_83','Swimmers touch pads',#11697,$,$); +#11705=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_80_84','Swimming race start sound generators',#11697,$,$); +#11706=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_80_85','Swimming timing controllers',#11697,$,$); +#11707=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_88','Telecoms equipment',#11598,$,$); +#11708=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_88_01','Acoustic hoods',#11707,$,$); +#11709=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_88_03','Analogue telephone handsets',#11707,$,$); +#11710=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_88_21','Data and telecom transient overvoltage surge suppression devices',#11707,$,$); +#11711=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_88_22','Digital enhanced cordless telecommunications (DECT) telephone handsets',#11707,$,$); +#11712=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_88_24','Digital terminals',#11707,$,$); +#11713=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_88_27','Emergency roadside telephones',#11707,$,$); +#11714=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_88_60','Payphones',#11707,$,$); +#11715=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_88_83','Telecommunications system controllers',#11707,$,$); +#11716=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_88_86','Telephone distribution frames',#11707,$,$); +#11717=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_88_87','Telephone extension ringers',#11707,$,$); +#11718=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_88_89','Telephone operator consoles',#11707,$,$); +#11719=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_94','Visual and audible indicators',#11598,$,$); +#11720=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_94_27','Electric door bells',#11719,$,$); +#11721=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_94_28','Electronic sounders',#11719,$,$); +#11722=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_94_29','Flashing filament warning beacons',#11719,$,$); +#11723=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_94_40','Indicator lights',#11719,$,$); +#11724=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_94_42','Industrial bells',#11719,$,$); +#11725=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_94_46','LED warning beacons',#11719,$,$); +#11726=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_94_58','Overdoor indicator units',#11719,$,$); +#11727=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_94_60','Panel mounting indicator lights',#11719,$,$); +#11728=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_94_73','Rotating warning beacons',#11719,$,$); +#11729=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_94_78','Starting strobe lights',#11719,$,$); +#11730=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_94_80','Static filament warning beacons',#11719,$,$); +#11731=IFCCLASSIFICATIONREFERENCE($,'Pr_70_75_94_99','Xenon warning beacons',#11719,$,$); +#11732=IFCCLASSIFICATIONREFERENCE($,'Pr_75','Services control products',#4923,$,$); +#11733=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30','Opening control products',#11732,$,$); +#11734=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23','Door and gate operating hardware',#11733,$,$); +#11735=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_00','Articulated arm swing gate operators',#11734,$,$); +#11736=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_01','Automatic door access control mats',#11734,$,$); +#11737=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_02','Automatic door presence safety sensors',#11734,$,$); +#11738=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_03','Automatic gate presence safety sensors',#11734,$,$); +#11739=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_04','Automatic sliding door operator control panels',#11734,$,$); +#11740=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_05','Automatic sliding door operators',#11734,$,$); +#11741=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_06','Automatic sliding gate operator control panels',#11734,$,$); +#11742=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_07','Automatic swing door operator control panels',#11734,$,$); +#11743=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_08','Automatic swing gate operator control panels',#11734,$,$); +#11744=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_09','Automatic swing-door operators',#11734,$,$); +#11745=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_21','Dock leveller controllers',#11734,$,$); +#11746=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_22','Door access control pushpads',#11734,$,$); +#11747=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_26','Electromagnetic door holders',#11734,$,$); +#11748=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_27','Electromagnetic door hold-open and swing-free devices',#11734,$,$); +#11749=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_31','Folding gate automation mechanisms',#11734,$,$); +#11750=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_33','Garage door operators',#11734,$,$); +#11751=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_36','Handheld door and gate remote controllers',#11734,$,$); +#11752=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_40','Hinged and swing gate automation mechanisms',#11734,$,$); +#11753=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_42','Hydraulic automation mechanisms',#11734,$,$); +#11754=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_70','Rack and pinion sliding gate operators',#11734,$,$); +#11755=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_72','Rising arm automation mechanisms',#11734,$,$); +#11756=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_76','Sliding gate automation mechanisms',#11734,$,$); +#11757=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_92','Underground swing gate operators',#11734,$,$); +#11758=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_94','Vehicle induction loop detectors',#11734,$,$); +#11759=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_23_96','Worm drive swing gate operators',#11734,$,$); +#11760=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_27','Electric door locking hardware',#11733,$,$); +#11761=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_27_26','Electric strikes and faceplates',#11760,$,$); +#11762=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_27_27','Electromechanical door locks',#11760,$,$); +#11763=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_27_50','Magnetic locks',#11760,$,$); +#11764=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_27_51','Magnetic shear locks and strike plates',#11760,$,$); +#11765=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_27_77','Shear locks and strike plates',#11760,$,$); +#11766=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_27_80','Solenoid bolts',#11760,$,$); +#11767=IFCCLASSIFICATIONREFERENCE($,'Pr_75_30_27_81','Solenoid latches and locks',#11760,$,$); +#11768=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50','Mechanical and electrical services control products',#11732,$,$); +#11769=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18','Controllers and control panels',#11768,$,$); +#11770=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_02','Alarms',#11769,$,$); +#11771=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_04','Automatic sprinkler system indicator panels',#11769,$,$); +#11772=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_06','Automatic sprinkler electric pump control panels',#11769,$,$); +#11773=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_10','Bus section control panels',#11769,$,$); +#11774=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_11','Cableways section panels',#11769,$,$); +#11775=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_13','Chain actuators',#11769,$,$); +#11776=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_15','Compressed air master controllers',#11769,$,$); +#11777=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_16','Control circuit supplies panels',#11769,$,$); +#11778=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_17','Control panels',#11769,$,$); +#11779=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_21','Damper actuators',#11769,$,$); +#11780=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_26','Electric trace heating control and monitoring panels',#11769,$,$); +#11781=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_28','Feeder section control panels',#11769,$,$); +#11782=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_29','Field controllers',#11769,$,$); +#11783=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_30','Flow sample gas detection control panels',#11769,$,$); +#11784=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_31','Fire system indicator panels',#11769,$,$); +#11785=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_32','FIre electric pump control panels',#11769,$,$); +#11786=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_33','Gas detection control panels',#11769,$,$); +#11787=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_34','Gas dose regulators',#11769,$,$); +#11788=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_37','Help point control panels',#11769,$,$); +#11789=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_40','Incoming supply control panels',#11769,$,$); +#11790=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_41','Instrumentation, automation and control panels',#11769,$,$); +#11791=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_42','Irrigation control panels',#11769,$,$); +#11792=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_45','Lift control panels',#11769,$,$); +#11793=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_46','Linear actuators',#11769,$,$); +#11794=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_47','Liquid leak detection control panels',#11769,$,$); +#11795=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_51','Mechanical services control panels',#11769,$,$); +#11796=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_53','Motor starters control panels',#11769,$,$); +#11797=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_65','Pneumatic document conveyor control panels',#11769,$,$); +#11798=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_66','Points heating control panels',#11769,$,$); +#11799=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_67','Power factor correction control panels',#11769,$,$); +#11800=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_69','Power quality filter section panels',#11769,$,$); +#11801=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_70','Programmers',#11769,$,$); +#11802=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_80','Smoke and heat exhaust control panels',#11769,$,$); +#11803=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_82','Solar collector control units',#11769,$,$); +#11804=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_90','Telemetry control panels',#11769,$,$); +#11805=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_92','Uninterruptible power supply control panels',#11769,$,$); +#11806=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_93','Utility supply control panels',#11769,$,$); +#11807=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_94','Valve actuators',#11769,$,$); +#11808=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_96','Water display controls',#11769,$,$); +#11809=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_98','Water quality controllers',#11769,$,$); +#11810=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_18_99','Wind operated water display control devices',#11769,$,$); +#11811=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_33','Gas fire extinguishing controls',#11768,$,$); +#11812=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_33_25','Electrical actuation devices',#11811,$,$); +#11813=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_33_26','Emergency abort devices',#11811,$,$); +#11814=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_33_27','Emergency hold devices',#11811,$,$); +#11815=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_33_28','Extinguishing control panels',#11811,$,$); +#11816=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_33_50','Manual triggering devices',#11811,$,$); +#11817=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_33_56','Non-electrical gas fire extinguishing disable devices',#11811,$,$); +#11818=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_33_64','Pneumatic heat actuators',#11811,$,$); +#11819=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_33_88','Thermal links',#11811,$,$); +#11820=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_46','Liquid level controllers and switches',#11768,$,$); +#11821=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_46_27','Electronic liquid level controllers',#11820,$,$); +#11822=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_46_29','Float liquid level controllers',#11820,$,$); +#11823=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_46_30','Float switches',#11820,$,$); +#11824=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_46_31','Flush control devices',#11820,$,$); +#11825=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_46_42','Infrared flush controllers',#11820,$,$); +#11826=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_46_46','Level controls and alarms',#11820,$,$); +#11827=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_46_68','Push button flush controllers',#11820,$,$); +#11828=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47','Liquid level sensors',#11768,$,$); +#11829=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_08','Buoyancy level sensors and switches',#11828,$,$); +#11830=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_11','Capacitance and inductance sensors',#11828,$,$); +#11831=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_34','Gravimetric and load cell sensors',#11828,$,$); +#11832=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_35','Guided wave radar sensors',#11828,$,$); +#11833=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_39','Hydrostatic sensors',#11828,$,$); +#11834=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_50','Magnetic level gauge switches',#11828,$,$); +#11835=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_51','Magnetorestrictive level transmitters',#11828,$,$); +#11836=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_53','Maximum water level recorders',#11828,$,$); +#11837=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_70','Radar sensors',#11828,$,$); +#11838=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_73','Rotary paddle sensors',#11828,$,$); +#11839=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_88','Thermal dispersion level switches',#11828,$,$); +#11840=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_92','Ultrasonic sensors',#11828,$,$); +#11841=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_94','Vibrating sensors',#11828,$,$); +#11842=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_96','Water level gauge boards',#11828,$,$); +#11843=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_47_97','Water level sensors',#11828,$,$); +#11844=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_48','Liquid sensing devices',#11768,$,$); +#11845=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_48_15','Chemical sensing cables',#11844,$,$); +#11846=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_48_31','Fuel sensing cables',#11844,$,$); +#11847=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_48_34','Ground water monitors',#11844,$,$); +#11848=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_48_47','Leak sensing tapes',#11844,$,$); +#11849=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_48_60','Pad leak sensors',#11844,$,$); +#11850=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_48_67','Probe leak sensors',#11844,$,$); +#11851=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_48_71','Remote sampling equipment',#11844,$,$); +#11852=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_48_90','Transportable monitors',#11844,$,$); +#11853=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_48_96','Water sensing cables',#11844,$,$); +#11854=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_50','Measuring and monitoring relays',#11768,$,$); +#11855=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_50_63','Phase monitoring relays',#11854,$,$); +#11856=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_51','Medical gases controls',#11768,$,$); +#11857=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_51_52','Medical gas area alarm panels',#11856,$,$); +#11858=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_51_54','Medical gases central alarms',#11856,$,$); +#11859=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_51_71','Remote start medical gas switch panels',#11856,$,$); +#11860=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_51_94','Vacuum insulated evaporator (VIE) control panels',#11856,$,$); +#11861=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_52','Meteorological instrumentation',#11768,$,$); +#11862=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_52_03','Anemometers',#11861,$,$); +#11863=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_52_06','Barometers',#11861,$,$); +#11864=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_52_12','Ceilometers',#11861,$,$); +#11865=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_52_39','Humidity and temperature probes',#11861,$,$); +#11866=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_52_65','Present weather sensors',#11861,$,$); +#11867=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_52_85','Storage rain gauges',#11861,$,$); +#11868=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_52_90','Tipping bucket rain gauges',#11861,$,$); +#11869=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_52_94','Visibility sensors',#11861,$,$); +#11870=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_52_97','Weather stations',#11861,$,$); +#11871=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_52_98','Weighing rain gauges',#11861,$,$); +#11872=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76','Sensors and detectors',#11768,$,$); +#11873=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_02','Air quality sensors',#11872,$,$); +#11874=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_03','Air temperature sensors',#11872,$,$); +#11875=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_04','Ambient noise level sensors',#11872,$,$); +#11876=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_12','Carbon monoxide detectors',#11872,$,$); +#11877=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_16','Combined electronic current and voltage transducers',#11872,$,$); +#11878=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_17','Combustion gas detectors',#11872,$,$); +#11879=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_18','Current sensors',#11872,$,$); +#11880=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_23','Disinfectant sensors',#11872,$,$); +#11881=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_24','Dissolved oxygen sensors',#11872,$,$); +#11882=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_25','Dry rot sensor sticks',#11872,$,$); +#11883=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_27','Electronic trace heating thermostats',#11872,$,$); +#11884=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_30','Flow in duct sensors',#11872,$,$); +#11885=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_31','Flow in pipe sensors',#11872,$,$); +#11886=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_33','Gas detectors',#11872,$,$); +#11887=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_47','Liquid temperature sensors',#11872,$,$); +#11888=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_51','Mechanical trace heating thermostats',#11872,$,$); +#11889=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_58','Occupancy sensors',#11872,$,$); +#11890=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_59','Passive infrared (PIR) sensors',#11872,$,$); +#11891=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_60','pH value sensors',#11872,$,$); +#11892=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_61','pH sensors',#11872,$,$); +#11893=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_63','Photoelectric sensors',#11872,$,$); +#11894=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_68','Pressure sensors',#11872,$,$); +#11895=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_69','Proximity sensors and control units',#11872,$,$); +#11896=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_71','Relative humidity sensors',#11872,$,$); +#11897=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_72','Residual chlorine sensors',#11872,$,$); +#11898=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_73','Room temperature sensors',#11872,$,$); +#11899=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_80','Sludge density sensors',#11872,$,$); +#11900=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_83','Steam and condensate sensor chambers',#11872,$,$); +#11901=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_84','Steam and condensate sensors',#11872,$,$); +#11902=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_86','Suspended solids sensors',#11872,$,$); +#11903=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_88','Toxic and combustible gas detectors',#11872,$,$); +#11904=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_90','Turbidity sensors',#11872,$,$); +#11905=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_95','Voltage sensors',#11872,$,$); +#11906=IFCCLASSIFICATIONREFERENCE($,'Pr_75_50_76_97','Water pressure sensors',#11872,$,$); +#11907=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51','Motors, motor controls, control circuit devices and timeswitches',#11732,$,$); +#11908=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_17','Control circuit devices and timeswitches',#11907,$,$); +#11909=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_17_27','Emergency stop buttons',#11908,$,$); +#11910=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_17_50','Manual control switches',#11908,$,$); +#11911=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_17_66','Push button switches',#11908,$,$); +#11912=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_17_75','Safety limit switches',#11908,$,$); +#11913=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_17_78','Selector switches',#11908,$,$); +#11914=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_17_87','Tariff and load control radio tele-switches',#11908,$,$); +#11915=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_17_88','Tariff and load control time switches',#11908,$,$); +#11916=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_17_89','Time switches',#11908,$,$); +#11917=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_26','Electric motors',#11907,$,$); +#11918=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_26_00','Alternating current (a.c.) capacitor start capacitor run motors',#11917,$,$); +#11919=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_26_01','Alternating current (a.c.) capacitor motors',#11917,$,$); +#11920=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_26_02','Alternating current (a.c.) split phase motors',#11917,$,$); +#11921=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_26_03','Alternating current (a.c.) squirrel cage induction motors',#11917,$,$); +#11922=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_26_04','Alternating current (a.c.) wound rotor induction motors',#11917,$,$); +#11923=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_26_21','Direct current (d.c.) compound wound motors',#11917,$,$); +#11924=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_26_22','Direct current (d.c.) permanent magnet motors',#11917,$,$); +#11925=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_26_23','Direct current (d.c.) separately excited motors',#11917,$,$); +#11926=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_26_24','Direct current (d.c.) series wound motors',#11917,$,$); +#11927=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_26_25','Direct current (d.c.) shunt wound motors',#11917,$,$); +#11928=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_26_92','Universal motors',#11917,$,$); +#11929=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_35','Gearboxes',#11907,$,$); +#11930=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_35_10','Bevel gearboxes',#11929,$,$); +#11931=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_35_35','Helical gearboxes',#11929,$,$); +#11932=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_35_65','Planetary gearboxes',#11929,$,$); +#11933=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_35_80','Spur gearboxes',#11929,$,$); +#11934=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_35_94','Variable speed hydraulic gearboxes',#11929,$,$); +#11935=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_35_97','Worm gearboxes',#11929,$,$); +#11936=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_52','Motor starters, variable frequency drives and contactors',#11907,$,$); +#11937=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_52_01','Alternating current (a.c.) drives',#11936,$,$); +#11938=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_52_02','Alternating current (a.c.) semiconductor motor controllers and starters',#11936,$,$); +#11939=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_52_15','Control and protective switching devices',#11936,$,$); +#11940=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_52_22','Direct-on-line starters',#11936,$,$); +#11941=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_52_26','Electro-mechanical contactors',#11936,$,$); +#11942=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_52_27','Electromechanical control circuit devices',#11936,$,$); +#11943=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_52_58','Overload relays',#11936,$,$); +#11944=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_52_82','Star delta starters',#11936,$,$); +#11945=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_65','Pneumatic motors',#11907,$,$); +#11946=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_65_05','Axial piston motors',#11945,$,$); +#11947=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_65_70','Radial piston motors',#11945,$,$); +#11948=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_65_73','Rotary vane motors',#11945,$,$); +#11949=IFCCLASSIFICATIONREFERENCE($,'Pr_75_51_65_90','Turbine air motors',#11945,$,$); +#11950=IFCCLASSIFICATIONREFERENCE($,'Pr_75_70','Power and lighting control products',#11732,$,$); +#11951=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75','Communications control products',#11732,$,$); +#11952=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04','Assistance and nurse call devices and control equipment',#11951,$,$); +#11953=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_00','Assistance call acoustic hoods',#11952,$,$); +#11954=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_01','Assistance call indicator units',#11952,$,$); +#11955=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_02','Assistance call power supply units',#11952,$,$); +#11956=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_03','Assistance call press button units',#11952,$,$); +#11957=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_04','Assistance call pull cord units',#11952,$,$); +#11958=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_05','Assistance call reset units',#11952,$,$); +#11959=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_57','Nurse call buttons',#11952,$,$); +#11960=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_58','Nurse call combined emergency/ patient call/ reset units',#11952,$,$); +#11961=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_60','Nurse call overdoor indicators',#11952,$,$); +#11962=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_61','Nurse call patient handsets',#11952,$,$); +#11963=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_62','Nurse call patient pull cords',#11952,$,$); +#11964=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_63','Nurse call power supply units',#11952,$,$); +#11965=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_64','Nurse call reset units',#11952,$,$); +#11966=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_65','Nurse call station indicator panels',#11952,$,$); +#11967=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_66','Nurse emergency pull-switches',#11952,$,$); +#11968=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_70','Passenger assistance help points',#11952,$,$); +#11969=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_04_71','Passenger assistance intercom handsets',#11952,$,$); +#11970=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15','Computers and peripherals',#11951,$,$); +#11971=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_11','Card printers',#11970,$,$); +#11972=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_14','Combined photocopier- printer- scanners',#11970,$,$); +#11973=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_15','Computer keyboards',#11970,$,$); +#11974=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_16','Computer monitors',#11970,$,$); +#11975=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_17','Computer mouse',#11970,$,$); +#11976=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_21','Desktop computers',#11970,$,$); +#11977=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_22','Digital cameras',#11970,$,$); +#11978=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_24','Display screen monitors',#11970,$,$); +#11979=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_36','Hard disk drives',#11970,$,$); +#11980=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_45','Keyboard extenders',#11970,$,$); +#11981=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_46','Laptop computers',#11970,$,$); +#11982=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_63','Photocopiers',#11970,$,$); +#11983=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_66','Printers',#11970,$,$); +#11984=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_76','Scanners',#11970,$,$); +#11985=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_80','Servers',#11970,$,$); +#11986=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_84','Slot card cages',#11970,$,$); +#11987=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_87','Tablet computers',#11970,$,$); +#11988=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_15_90','Touchscreen monitors',#11970,$,$); +#11989=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27','Electronic access control products',#11951,$,$); +#11990=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_01','Access control digital keypads - standalone',#11989,$,$); +#11991=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_03','Access control units',#11989,$,$); +#11992=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_05','Active proximity devices',#11989,$,$); +#11993=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_07','Biometric fingerprint readers',#11989,$,$); +#11994=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_08','Biometric hand geometry readers',#11989,$,$); +#11995=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_23','Door status monitoring devices',#11989,$,$); +#11996=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_27','Emergency door release break glass units',#11989,$,$); +#11997=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_28','Emergency door release mechanisms',#11989,$,$); +#11998=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_42','Intercom entrance panels',#11989,$,$); +#11999=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_43','Intercom remote handsets',#11989,$,$); +#12000=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_44','Intercom servers',#11989,$,$); +#12001=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_50','Magnetic swipe card readers',#11989,$,$); +#12002=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_51','Magnetic swipe cards',#11989,$,$); +#12003=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_55','Multiple technology cards',#11989,$,$); +#12004=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_57','Multi-technology readers',#11989,$,$); +#12005=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_60','Passive proximity devices',#11989,$,$); +#12006=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_67','Proximity card readers',#11989,$,$); +#12007=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_68','Proximity cards',#11989,$,$); +#12008=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_71','Request-to-exit buttons',#11989,$,$); +#12009=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_72','Request to exit detectors',#11989,$,$); +#12010=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_80','Smart card readers and writers',#11989,$,$); +#12011=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_27_82','Smart devices',#11989,$,$); +#12012=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30','Fire alarm detection devices and control equipment',#11951,$,$); +#12013=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_01','Aspirating sampling pipes',#12012,$,$); +#12014=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_02','Aspirating sampling points',#12012,$,$); +#12015=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_03','Aspirating smoke detectors',#12012,$,$); +#12016=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_04','Aspirating smoke detector units',#12012,$,$); +#12017=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_13','Carbon monoxide and heat multi-sensor detectors',#12012,$,$); +#12018=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_15','Combined smoke and heat detectors',#12012,$,$); +#12019=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_20','Domestic smoke and carbon monoxide detectors',#12012,$,$); +#12020=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_22','Duct smoke detectors',#12012,$,$); +#12021=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_29','Fire alarm panels',#12012,$,$); +#12022=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_30','Fire alarm sounders',#12012,$,$); +#12023=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_31','Fire detection and alarm power supply equipment',#12012,$,$); +#12024=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_37','Heat alarms',#12012,$,$); +#12025=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_41','Interface panels',#12012,$,$); +#12026=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_50','Manual call points',#12012,$,$); +#12027=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_52','Mimic alarm panels',#12012,$,$); +#12028=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_55','Multisensor detectors',#12012,$,$); +#12029=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_59','Optical beam smoke detectors',#12012,$,$); +#12030=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_63','Point flame detectors',#12012,$,$); +#12031=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_64','Point heat detectors',#12012,$,$); +#12032=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_65','Point smoke detectors',#12012,$,$); +#12033=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_70','Radio-linked interface modules',#12012,$,$); +#12034=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_71','Remote indicators',#12012,$,$); +#12035=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_77','Short-circuit isolators',#12012,$,$); +#12036=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_80','Smoke alarms',#12012,$,$); +#12037=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_81','Smoke and carbon monoxide multi-sensor detectors',#12012,$,$); +#12038=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_82','Smoke and heat multi-sensor detectors',#12012,$,$); +#12039=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_94','Vibrating pillow pads',#12012,$,$); +#12040=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_95','Vibrating radio pager transmitters',#12012,$,$); +#12041=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_96','Vibrating radio pagers',#12012,$,$); +#12042=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_97','Visual alarm signal devices',#12012,$,$); +#12043=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_30_98','Voice alarm control panels',#12012,$,$); +#12044=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_32','Foreign object debris (FOD) detection equipment',#11951,$,$); +#12045=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_32_27','Electro-optical FOD detection equipment',#12044,$,$); +#12046=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_32_39','Hybrid FOD detection equipment',#12044,$,$); +#12047=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_32_70','Radar FOD detection equipment',#12044,$,$); +#12048=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42','Intruder detection and alarm devices and control equipment',#11951,$,$); +#12049=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_02','Acoustic detectors',#12048,$,$); +#12050=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_08','Beam interruption detectors',#12048,$,$); +#12051=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_11','Capacitive proximity detectors',#12048,$,$); +#12052=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_16','Combined passive infrared and microwave detectors',#12048,$,$); +#12053=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_17','Combined passive infrared and ultrasonic detectors',#12048,$,$); +#12054=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_22','Deliberately operated intruder alarm devices',#12048,$,$); +#12055=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_24','Door beam intruder detectors',#12048,$,$); +#12056=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_28','External intruder alarm sounders',#12048,$,$); +#12057=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_40','Internal electronic intruder alarm sounders',#12048,$,$); +#12058=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_41','Intruder alarm panels',#12048,$,$); +#12059=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_42','Intruder alarm remote keypads',#12048,$,$); +#12060=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_52','Microwave detectors',#12048,$,$); +#12061=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_60','Passive infrared detectors',#12048,$,$); +#12062=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_67','Protective switches',#12048,$,$); +#12063=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_77','Security fog devices',#12048,$,$); +#12064=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_92','Ultrasonic movement detectors',#12048,$,$); +#12065=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_94','Vibrating intruder alarm pagers',#12048,$,$); +#12066=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_95','Vibration detectors',#12048,$,$); +#12067=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_42_96','Volumetric capacitive detectors',#12048,$,$); +#12068=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_47','Lift control products',#11951,$,$); +#12069=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_47_41','Illuminated landing indicators',#12068,$,$); +#12070=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_47_43','Infrared landing controls',#12068,$,$); +#12071=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_47_46','Landing call stations',#12068,$,$); +#12072=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_50','Monitoring system control products',#11951,$,$); +#12073=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_50_02','Alarm interface units',#12072,$,$); +#12074=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_50_11','Camera control units',#12072,$,$); +#12075=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_50_14','Camera power supply units',#12072,$,$); +#12076=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_50_22','Demagnetizers',#12072,$,$); +#12077=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_50_55','Multiplexors',#12072,$,$); +#12078=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_50_60','Patch panels',#12072,$,$); +#12079=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_50_70','Radio frequency (RF) modulators',#12072,$,$); +#12080=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_50_94','Video input cards',#12072,$,$); +#12081=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_50_95','Video matrix switch controllers',#12072,$,$); +#12082=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_50_96','Video output cards',#12072,$,$); +#12083=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_60','Passport control products',#11951,$,$); +#12084=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_60_07','Biometric facial recognition products',#12083,$,$); +#12085=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_60_08','Biometric iris recognition products',#12083,$,$); +#12086=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_60_60','Passport readers',#12083,$,$); +#12087=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_75','Security screening products',#11951,$,$); +#12088=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_75_01','Advanced cabin baggage x-ray scanners',#12087,$,$); +#12089=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_75_06','Back scatter x-ray security scanners',#12087,$,$); +#12090=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_75_28','Explosive trace detection equipment',#12087,$,$); +#12091=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_75_47','Liquid explosive detection equipment',#12087,$,$); +#12092=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_75_52','Millimetre wave security scanners',#12087,$,$); +#12093=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_75_96','Walk-through metal detectors',#12087,$,$); +#12094=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90','Transmission control products',#11951,$,$); +#12095=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_16','Converter receivers',#12094,$,$); +#12096=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_17','Converter senders',#12094,$,$); +#12097=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_27','Encoders and decoders',#12094,$,$); +#12098=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_30','Fibre receivers',#12094,$,$); +#12099=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_31','Fibre transmitters',#12094,$,$); +#12100=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_41','Infrared receivers',#12094,$,$); +#12101=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_42','Infrared transmitters',#12094,$,$); +#12102=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_50','Microwave transmission beacons',#12094,$,$); +#12103=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_52','Microwave transmitters',#12094,$,$); +#12104=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_65','Protocol converters',#12094,$,$); +#12105=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_70','Radio interface units',#12094,$,$); +#12106=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_71','Radio receivers',#12094,$,$); +#12107=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_78','Sender modules',#12094,$,$); +#12108=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_88','Telemetry receivers',#12094,$,$); +#12109=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_89','Telemetry senders',#12094,$,$); +#12110=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_90','Telemetry transmitters',#12094,$,$); +#12111=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_91','Transmission modules',#12094,$,$); +#12112=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_94','Video receivers',#12094,$,$); +#12113=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_90_95','Video transmitters',#12094,$,$); +#12114=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94','Voice alarm and emergency voice communication equipment',#11951,$,$); +#12115=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_03','Ambient noise sensing controllers',#12114,$,$); +#12116=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_11','Cabinet voice alarm loudspeakers',#12114,$,$); +#12117=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_15','Ceiling mounted voice alarm loudspeakers',#12114,$,$); +#12118=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_19','Column voice alarm loudspeakers',#12114,$,$); +#12119=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_22','Disabled refuge master stations',#12114,$,$); +#12120=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_23','Disabled refuge outstations',#12114,$,$); +#12121=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_27','Emergency voice communication radio based equipment',#12114,$,$); +#12122=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_37','Horn voice alarm loudspeakers',#12114,$,$); +#12123=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_41','Input cards',#12114,$,$); +#12124=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_58','Output cards',#12114,$,$); +#12125=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_60','Paging microphones',#12114,$,$); +#12126=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_70','Radio microphones',#12114,$,$); +#12127=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_72','Radio public address interface boards',#12114,$,$); +#12128=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_74','Refuge point master stations',#12114,$,$); +#12129=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_76','Refuge point outstations',#12114,$,$); +#12130=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_93','Voice alarm control console',#12114,$,$); +#12131=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_94','Voice alarm controller microphones',#12114,$,$); +#12132=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_95','Voice alarm controllers',#12114,$,$); +#12133=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_96','Voice alarm emergency microphones',#12114,$,$); +#12134=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_97','Voice alarm power amplifiers',#12114,$,$); +#12135=IFCCLASSIFICATIONREFERENCE($,'Pr_75_75_94_98','Voice alarm power supply units',#12114,$,$); +#12136=IFCCLASSIFICATIONREFERENCE($,'Pr_80','Services general products',#4923,$,$); +#12137=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51','Measuring and metering products',#12136,$,$); +#12138=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_30','Measuring flumes',#12137,$,$); +#12139=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_30_20','Cutthroat flumes',#12138,$,$); +#12140=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_30_38','HS/H/HL flumes',#12138,$,$); +#12141=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_30_52','Montana flumes',#12138,$,$); +#12142=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_30_60','Palmer-Bowlus flumes',#12138,$,$); +#12143=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_30_61','Parshall flumes',#12138,$,$); +#12144=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_30_70','RBC flumes',#12138,$,$); +#12145=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_30_90','Trapezoidal flumes',#12138,$,$); +#12146=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_30_94','Venturi flumes',#12138,$,$); +#12147=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_46','Liquid flow meters',#12137,$,$); +#12148=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_46_15','Coriolis flowmeters',#12147,$,$); +#12149=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_46_27','Electromagnetic flow meters',#12147,$,$); +#12150=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_46_55','Multiphase flowmeters',#12147,$,$); +#12151=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_46_66','Primary flow differential pressure flowmeters',#12147,$,$); +#12152=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_46_73','Rotary piston flowmeters',#12147,$,$); +#12153=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_46_85','Swirl flowmeters',#12147,$,$); +#12154=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_46_88','Thermal mass flowmeters',#12147,$,$); +#12155=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_46_92','Ultrasonic flowmeters',#12147,$,$); +#12156=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51','Metering and test products',#12137,$,$); +#12157=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_04','Analogue metering equipment',#12156,$,$); +#12158=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_05','Ammeters',#12156,$,$); +#12159=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_06','Audio frequency induction loop field strength meters',#12156,$,$); +#12160=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_11','Call information logging equipment',#12156,$,$); +#12161=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_15','Corrosion monitors',#12156,$,$); +#12162=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_19','Current transformers',#12156,$,$); +#12163=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_21','Differential pressure flow meters',#12156,$,$); +#12164=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_22','Digital metering equipment',#12156,$,$); +#12165=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_23','Digital multifunction metering equipment',#12156,$,$); +#12166=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_28','Energy meters',#12156,$,$); +#12167=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_30','Frequency meters',#12156,$,$); +#12168=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_32','Fuel meters',#12156,$,$); +#12169=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_33','Gas meters',#12156,$,$); +#12170=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_37','Heat meters',#12156,$,$); +#12171=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_50','Mass flow meters',#12156,$,$); +#12172=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_57','Ohm meters',#12156,$,$); +#12173=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_58','Oil meters',#12156,$,$); +#12174=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_60','Phase meters',#12156,$,$); +#12175=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_62','Piezometers',#12156,$,$); +#12176=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_63','Power factor meters',#12156,$,$); +#12177=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_64','Portable gas monitors',#12156,$,$); +#12178=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_65','Portable leak monitors',#12156,$,$); +#12179=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_66','Portable moisture monitors',#12156,$,$); +#12180=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_67','Pressure meters',#12156,$,$); +#12181=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_80','Soil moisture monitors',#12156,$,$); +#12182=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_92','Ultrasonic flow meters',#12156,$,$); +#12183=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_93','Vapour meters',#12156,$,$); +#12184=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_94','Variable area flow meters',#12156,$,$); +#12185=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_95','Voltmeters',#12156,$,$); +#12186=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_96','Vortex flow meters',#12156,$,$); +#12187=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_97','Water meters',#12156,$,$); +#12188=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_51_98','Wattmeters',#12156,$,$); +#12189=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_70','Rail and road measuring products',#12137,$,$); +#12190=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_70_22','Digital straight edge gauges',#12189,$,$); +#12191=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_70_44','Junction work gauges',#12189,$,$); +#12192=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_70_64','Platform gauges',#12189,$,$); +#12193=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_70_85','Straight edge gauges',#12189,$,$); +#12194=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_70_88','Track geometry trolleys',#12189,$,$); +#12195=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_70_89','Track gauges',#12189,$,$); +#12196=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_70_90','Tunnel gauges',#12189,$,$); +#12197=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85','Structural instrumentation and monitoring products',#12137,$,$); +#12198=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_01','Accelerometers',#12197,$,$); +#12199=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_18','Crack gauges',#12197,$,$); +#12200=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_21','Data loggers',#12197,$,$); +#12201=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_27','Electrolevel sensor and microelectromechanical units',#12197,$,$); +#12202=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_28','Extensometers',#12197,$,$); +#12203=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_41','Inclinometers',#12197,$,$); +#12204=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_45','Linear movement detectors',#12197,$,$); +#12205=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_46','Liquid level gauges',#12197,$,$); +#12206=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_47','Load cells',#12197,$,$); +#12207=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_48','Logger box and readout box',#12197,$,$); +#12208=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_66','Precise levels',#12197,$,$); +#12209=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_84','Strain gauges',#12197,$,$); +#12210=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_87','Tape extensometers',#12197,$,$); +#12211=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_88','Tilt meters',#12197,$,$); +#12212=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_85_90','Total stations',#12197,$,$); +#12213=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_96','Weighbridge products',#12137,$,$); +#12214=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_96_00','Above ground weighbridges',#12213,$,$); +#12215=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_96_32','Fully inground weighbridges',#12213,$,$); +#12216=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_96_55','Multiple deck weighbridges',#12213,$,$); +#12217=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_96_71','Relocatable weighbridges',#12213,$,$); +#12218=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_96_77','Semi-pit weighbridges',#12213,$,$); +#12219=IFCCLASSIFICATIONREFERENCE($,'Pr_80_51_96_96','Wheel weigh pads',#12213,$,$); +#12220=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77','Services support and containment products',#12136,$,$); +#12221=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_23','Dock shelters',#12220,$,$); +#12222=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_23_30','Flap dock shelters',#12221,$,$); +#12223=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_23_31','Foam pad (cushion) dock seals',#12221,$,$); +#12224=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_23_42','Inflatable dock shelters',#12221,$,$); +#12225=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_23_70','Retractable dock shelters',#12221,$,$); +#12226=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_23_71','Rigid dock shelters',#12221,$,$); +#12227=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_23_72','Rigid dock shelters with inflatable seals',#12221,$,$); +#12228=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27','Equipment boards, racks and supports',#12220,$,$); +#12229=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_04','Audio-visual equipment racks',#12228,$,$); +#12230=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_07','Ballasted mounting frames for solar modules',#12228,$,$); +#12231=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_08','Battery shelving racks',#12228,$,$); +#12232=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_15','Channel supports',#12228,$,$); +#12233=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_31','Free standing mounting frames for solar modules',#12228,$,$); +#12234=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_33','Gauge mounting boards',#12228,$,$); +#12235=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_42','IT and telecommunications equipment racks',#12228,$,$); +#12236=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_51','Metal cladding solar module clamps',#12228,$,$); +#12237=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_53','Mounting plates',#12228,$,$); +#12238=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_54','Multi-service transit seals',#12228,$,$); +#12239=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_72','Roof anchors for solar modules',#12228,$,$); +#12240=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_73','Roof equipment supports',#12228,$,$); +#12241=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_80','Solar module support rails',#12228,$,$); +#12242=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_27_91','Turbine support structures',#12228,$,$); +#12243=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28','Equipment enclosures, cabinets, boxes and housings',#12220,$,$); +#12244=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_06','Balanced twisted-pair cabling patch panels',#12243,$,$); +#12245=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_07','Boundary boxes',#12243,$,$); +#12246=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_08','Cable junction boxes',#12243,$,$); +#12247=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_09','Cable termination boxes',#12243,$,$); +#12248=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_10','Camera brackets',#12243,$,$); +#12249=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_11','Camera housings',#12243,$,$); +#12250=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_13','Central battery enclosures',#12243,$,$); +#12251=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_16','Control circuit device enclosures',#12243,$,$); +#12252=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_21','Data equipment cabinets',#12243,$,$); +#12253=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_22','Display monitor housings',#12243,$,$); +#12254=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_24','Dry riser landing boxes',#12243,$,$); +#12255=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_26','Fibre joint enclosures',#12243,$,$); +#12256=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_27','Fibre optic patch panels',#12243,$,$); +#12257=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_28','Fire equipment cabinets',#12243,$,$); +#12258=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_29','Fire extinguisher cabinets',#12243,$,$); +#12259=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_30','Fire hose cabinets',#12243,$,$); +#12260=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_33','Generator enclosures',#12243,$,$); +#12261=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_46','Large fire hydrant surface boxes',#12243,$,$); +#12262=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_47','Loudspeaker protective cages',#12243,$,$); +#12263=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_48','Loudspeaker rear protective enclosures',#12243,$,$); +#12264=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_49','Low voltage switchgear enclosures',#12243,$,$); +#12265=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_52','Meter cabinets',#12243,$,$); +#12266=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_60','Padlock and key cabinets',#12243,$,$); +#12267=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_65','Power factor correction equipment enclosures',#12243,$,$); +#12268=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_70','Rack cabinets',#12243,$,$); +#12269=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_77','Switchgear enclosures',#12243,$,$); +#12270=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_78','Switchgear extension frames',#12243,$,$); +#12271=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_84','Surveillance camera brackets',#12243,$,$); +#12272=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_85','Surveillance camera housings',#12243,$,$); +#12273=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_86','Telephone enclosures',#12243,$,$); +#12274=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_88','Terminal air filter housings',#12243,$,$); +#12275=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_94','Valve boxes',#12243,$,$); +#12276=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_95','Video recorder cabinets',#12243,$,$); +#12277=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_96','Water fire extinguishing inlet boxes',#12243,$,$); +#12278=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_97','Water fire extinguishing surface boxes',#12243,$,$); +#12279=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_28_98','Weatherproof equipment enclosures',#12243,$,$); +#12280=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_46','Lift enclosures, access and supports',#12220,$,$); +#12281=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_46_32','Free standing self-supporting lift shafts',#12280,$,$); +#12282=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_46_46','Lift cars',#12280,$,$); +#12283=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48','Lighting columns, brackets and bollards',#12220,$,$); +#12284=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_01','Aluminium column luminaire brackets',#12283,$,$); +#12285=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_02','Aluminium lighting bollards',#12283,$,$); +#12286=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_03','Aluminium lighting columns',#12283,$,$); +#12287=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_04','Aluminium luminaire brackets',#12283,$,$); +#12288=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_15','Concrete lighting bollards',#12283,$,$); +#12289=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_16','Concrete lighting columns',#12283,$,$); +#12290=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_23','Double lighting columns',#12283,$,$); +#12291=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_55','Multiple light columns',#12283,$,$); +#12292=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_63','Plastics lighting bollards',#12283,$,$); +#12293=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_64','Plastics lighting columns',#12283,$,$); +#12294=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_78','Steel column luminaire brackets',#12283,$,$); +#12295=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_79','Steel lighting bollards',#12283,$,$); +#12296=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_80','Steel lighting columns',#12283,$,$); +#12297=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_48_81','Steel luminaire brackets',#12283,$,$); +#12298=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76','Services insulation and protection products',#12220,$,$); +#12299=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_03','Aluminium sheet insulation casing',#12298,$,$); +#12300=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_11','Calcium silicate preformed section and slab insulation',#12298,$,$); +#12301=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_12','Canvas insulation protection',#12298,$,$); +#12302=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_13','Carbon steel sheet insulation casing',#12298,$,$); +#12303=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_25','Ethylene propylene diene monomer (EPDM) rubber insulation',#12298,$,$); +#12304=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_29','Flexible elastomeric foam insulation',#12298,$,$); +#12305=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_34','Glass wool cloth insulation protection',#12298,$,$); +#12306=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_47','Loadbearing pipeline support insulation',#12298,$,$); +#12307=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_52','Mineral wool duct metal mesh faced mattress insulation',#12298,$,$); +#12308=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_53','Mineral wool duct slab insulation',#12298,$,$); +#12309=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_54','Mineral wool pipe section insulation',#12298,$,$); +#12310=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_58','Nitrile rubber insulation',#12298,$,$); +#12311=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_62','Phenolic foam insulation',#12298,$,$); +#12312=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_64','Polyisobutylene insulation protection',#12298,$,$); +#12313=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_65','Polyisocyanurate (PIR) insulation',#12298,$,$); +#12314=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_76','Self-adhesive insulation casing',#12298,$,$); +#12315=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_85','Stainless steel sheet insulation casing',#12298,$,$); +#12316=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_92','Unplasticized polyvinylchloride (PVC-U) sheet insulation casing',#12298,$,$); +#12317=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_94','Valve and flange insulation',#12298,$,$); +#12318=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_76_95','Valve and flange insulation casing',#12298,$,$); +#12319=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_94','Vibration isolation products',#12220,$,$); +#12320=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_94_15','Compression isolators',#12319,$,$); +#12321=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_94_30','Flexible vibration isolation hoses',#12319,$,$); +#12322=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_94_40','Inertia bases',#12319,$,$); +#12323=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_94_42','Isolation hangers',#12319,$,$); +#12324=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_94_50','Mat mountings',#12319,$,$); +#12325=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_94_60','Pad mountings',#12319,$,$); +#12326=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_94_65','Pneumatic isolation mounts',#12319,$,$); +#12327=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_94_74','Rubber bellows',#12319,$,$); +#12328=IFCCLASSIFICATIONREFERENCE($,'Pr_80_77_94_84','Spring isolators',#12319,$,$); +#12329=IFCCLASSIFICATIONREFERENCE($,'Pr_85','Process engineering products',#4923,$,$); +#12330=IFCCLASSIFICATIONREFERENCE($,'Pr_85_51','Milling products',#12329,$,$); +#12331=IFCCLASSIFICATIONREFERENCE($,'Pr_85_51_34','Grain milling products',#12330,$,$); +#12332=IFCCLASSIFICATIONREFERENCE($,'Pr_85_51_34_51','Millstones',#12331,$,$); +#12333=IFCCLASSIFICATIONREFERENCE($,'Pr_85_51_51','Mineral milling products',#12330,$,$); +#12334=IFCCLASSIFICATIONREFERENCE($,'Pr_85_51_87','Textile milling products',#12330,$,$); +#12335=IFCCLASSIFICATIONREFERENCE($,'Pr_85_51_88','Timber milling products',#12330,$,$); +#12336=IFCCLASSIFICATIONREFERENCE($,'Pr_85_73','Robotic products',#12329,$,$); +#12337=IFCCLASSIFICATIONREFERENCE($,'Pr_90','Soft facility management products',#4923,$,$); +#12338=IFCCLASSIFICATIONREFERENCE($,'Zz','CAD',#2,$,$); +#12339=IFCCLASSIFICATIONREFERENCE($,'Zz_10','Title sheet',#12338,$,$); +#12340=IFCCLASSIFICATIONREFERENCE($,'Zz_10_20','Drawing frame',#12339,$,$); +#12341=IFCCLASSIFICATIONREFERENCE($,'Zz_10_20_45','Logo',#12340,$,$); +#12342=IFCCLASSIFICATIONREFERENCE($,'Zz_10_20_95','Viewports',#12340,$,$); +#12343=IFCCLASSIFICATIONREFERENCE($,'Zz_10_40','Hold clouds and notation',#12339,$,$); +#12344=IFCCLASSIFICATIONREFERENCE($,'Zz_10_70','Revisions',#12339,$,$); +#12345=IFCCLASSIFICATIONREFERENCE($,'Zz_10_70_05','Annotation',#12344,$,$); +#12346=IFCCLASSIFICATIONREFERENCE($,'Zz_10_70_10','Blocks and cells',#12344,$,$); +#12347=IFCCLASSIFICATIONREFERENCE($,'Zz_10_70_20','Clouds and notations',#12344,$,$); +#12348=IFCCLASSIFICATIONREFERENCE($,'Zz_10_80','Status stamps',#12339,$,$); +#12349=IFCCLASSIFICATIONREFERENCE($,'Zz_20','Textual content',#12338,$,$); +#12350=IFCCLASSIFICATIONREFERENCE($,'Zz_20_10','Annotation',#12349,$,$); +#12351=IFCCLASSIFICATIONREFERENCE($,'Zz_20_10_40','Keynotes',#12350,$,$); +#12352=IFCCLASSIFICATIONREFERENCE($,'Zz_20_10_45','Labels',#12350,$,$); +#12353=IFCCLASSIFICATIONREFERENCE($,'Zz_20_10_50','Leaders',#12350,$,$); +#12354=IFCCLASSIFICATIONREFERENCE($,'Zz_20_10_55','Notes',#12350,$,$); +#12355=IFCCLASSIFICATIONREFERENCE($,'Zz_20_10_70','Reference',#12350,$,$); +#12356=IFCCLASSIFICATIONREFERENCE($,'Zz_20_10_85','Tags',#12350,$,$); +#12357=IFCCLASSIFICATIONREFERENCE($,'Zz_20_10_90','Text',#12350,$,$); +#12358=IFCCLASSIFICATIONREFERENCE($,'Zz_20_20','Dimensions',#12349,$,$); +#12359=IFCCLASSIFICATIONREFERENCE($,'Zz_20_30','General masking',#12349,$,$); +#12360=IFCCLASSIFICATIONREFERENCE($,'Zz_20_30_50','Masks',#12359,$,$); +#12361=IFCCLASSIFICATIONREFERENCE($,'Zz_20_30_95','Wipeouts',#12359,$,$); +#12362=IFCCLASSIFICATIONREFERENCE($,'Zz_20_40','Hatching',#12349,$,$); +#12363=IFCCLASSIFICATIONREFERENCE($,'Zz_20_40_05','Area fill',#12362,$,$); +#12364=IFCCLASSIFICATIONREFERENCE($,'Zz_20_40_35','Hatch boundaries',#12362,$,$); +#12365=IFCCLASSIFICATIONREFERENCE($,'Zz_20_40_60','Pattern',#12362,$,$); +#12366=IFCCLASSIFICATIONREFERENCE($,'Zz_20_40_80','Solid fill',#12362,$,$); +#12367=IFCCLASSIFICATIONREFERENCE($,'Zz_20_70','Redlining',#12349,$,$); +#12368=IFCCLASSIFICATIONREFERENCE($,'Zz_20_70_20','Comments',#12367,$,$); +#12369=IFCCLASSIFICATIONREFERENCE($,'Zz_20_80','Symbols',#12349,$,$); +#12370=IFCCLASSIFICATIONREFERENCE($,'Zz_20_80_10','Barscales',#12369,$,$); +#12371=IFCCLASSIFICATIONREFERENCE($,'Zz_20_80_15','Cross references',#12369,$,$); +#12372=IFCCLASSIFICATIONREFERENCE($,'Zz_20_80_40','Key plan',#12369,$,$); +#12373=IFCCLASSIFICATIONREFERENCE($,'Zz_20_80_50','Legends',#12369,$,$); +#12374=IFCCLASSIFICATIONREFERENCE($,'Zz_20_80_55','North point',#12369,$,$); +#12375=IFCCLASSIFICATIONREFERENCE($,'Zz_20_90','Title annotation',#12349,$,$); +#12376=IFCCLASSIFICATIONREFERENCE($,'Zz_30','Insertions',#12338,$,$); +#12377=IFCCLASSIFICATIONREFERENCE($,'Zz_30_20','Blocks and cells',#12376,$,$); +#12378=IFCCLASSIFICATIONREFERENCE($,'Zz_30_30','External references',#12376,$,$); +#12379=IFCCLASSIFICATIONREFERENCE($,'Zz_30_40','Images',#12376,$,$); +#12380=IFCCLASSIFICATIONREFERENCE($,'Zz_30_60','Objects',#12376,$,$); +#12381=IFCCLASSIFICATIONREFERENCE($,'Zz_30_90','Tables and schedules',#12376,$,$); +#12382=IFCCLASSIFICATIONREFERENCE($,'Zz_35','Setting out',#12338,$,$); +#12383=IFCCLASSIFICATIONREFERENCE($,'Zz_35_10','Alignments and super elevations',#12382,$,$); +#12384=IFCCLASSIFICATIONREFERENCE($,'Zz_35_10_40','Horizontal alignment',#12383,$,$); +#12385=IFCCLASSIFICATIONREFERENCE($,'Zz_35_10_80','Super elevation',#12383,$,$); +#12386=IFCCLASSIFICATIONREFERENCE($,'Zz_35_10_90','Vertical alignment',#12383,$,$); +#12387=IFCCLASSIFICATIONREFERENCE($,'Zz_35_20','Centrelines',#12382,$,$); +#12388=IFCCLASSIFICATIONREFERENCE($,'Zz_35_30','Geospatial control points',#12382,$,$); +#12389=IFCCLASSIFICATIONREFERENCE($,'Zz_35_40','Gridlines',#12382,$,$); +#12390=IFCCLASSIFICATIONREFERENCE($,'Zz_35_40_20','Ceiling grid',#12389,$,$); +#12391=IFCCLASSIFICATIONREFERENCE($,'Zz_35_40_80','Structural grid',#12389,$,$); +#12392=IFCCLASSIFICATIONREFERENCE($,'Zz_35_60','Points',#12382,$,$); +#12393=IFCCLASSIFICATIONREFERENCE($,'Zz_35_80','Survey control points',#12382,$,$); +#12394=IFCCLASSIFICATIONREFERENCE($,'Zz_35_80_55','OS bench mark',#12393,$,$); +#12395=IFCCLASSIFICATIONREFERENCE($,'Zz_35_80_60','OS trigonometrical station',#12393,$,$); +#12396=IFCCLASSIFICATIONREFERENCE($,'Zz_35_80_80','Site bench mark',#12393,$,$); +#12397=IFCCLASSIFICATIONREFERENCE($,'Zz_35_80_85','Site survey control station',#12393,$,$); +#12398=IFCCLASSIFICATIONREFERENCE($,'Zz_35_80_90','Temporary bench mark',#12393,$,$); +#12399=IFCCLASSIFICATIONREFERENCE($,'Zz_40','Topography',#12338,$,$); +#12400=IFCCLASSIFICATIONREFERENCE($,'Zz_40_15','Contours',#12399,$,$); +#12401=IFCCLASSIFICATIONREFERENCE($,'Zz_40_15_50','Major contours',#12400,$,$); +#12402=IFCCLASSIFICATIONREFERENCE($,'Zz_40_15_55','Minor contours',#12400,$,$); +#12403=IFCCLASSIFICATIONREFERENCE($,'Zz_40_20','Cuttings and embankment indicators',#12399,$,$); +#12404=IFCCLASSIFICATIONREFERENCE($,'Zz_40_50','Level indicators',#12399,$,$); +#12405=IFCCLASSIFICATIONREFERENCE($,'Zz_50','Zones and boundaries',#12338,$,$); +#12406=IFCCLASSIFICATIONREFERENCE($,'Zz_50_10','Boundaries',#12405,$,$); +#12407=IFCCLASSIFICATIONREFERENCE($,'Zz_50_10_10','Blue line boundary (BS 8541-2)',#12406,$,$); +#12408=IFCCLASSIFICATIONREFERENCE($,'Zz_50_10_70','Red line boundary (BS 8541-2)',#12406,$,$); +#12409=IFCCLASSIFICATIONREFERENCE($,'Zz_50_50','Lots',#12405,$,$); +#12410=IFCCLASSIFICATIONREFERENCE($,'Zz_50_60','Parcels',#12405,$,$); +#12411=IFCCLASSIFICATIONREFERENCE($,'Zz_50_90','Volumes',#12405,$,$); +#12412=IFCCLASSIFICATIONREFERENCE($,'Zz_50_95','Zones',#12405,$,$); +#12413=IFCCLASSIFICATIONREFERENCE($,'Zz_60','Drawing symbols',#12338,$,$); +#12414=IFCCLASSIFICATIONREFERENCE($,'Zz_60_20','Detail call ups',#12413,$,$); +#12415=IFCCLASSIFICATIONREFERENCE($,'Zz_60_30','Fall indicators',#12413,$,$); +#12416=IFCCLASSIFICATIONREFERENCE($,'Zz_60_40','Joint lines',#12413,$,$); +#12417=IFCCLASSIFICATIONREFERENCE($,'Zz_60_40_15','Construction joints',#12416,$,$); +#12418=IFCCLASSIFICATIONREFERENCE($,'Zz_60_40_20','Contraction joints',#12416,$,$); +#12419=IFCCLASSIFICATIONREFERENCE($,'Zz_60_40_30','Expansion joints',#12416,$,$); +#12420=IFCCLASSIFICATIONREFERENCE($,'Zz_60_45','Levels',#12413,$,$); +#12421=IFCCLASSIFICATIONREFERENCE($,'Zz_60_45_20','Datum',#12420,$,$); +#12422=IFCCLASSIFICATIONREFERENCE($,'Zz_60_45_60','Original ground level',#12420,$,$); +#12423=IFCCLASSIFICATIONREFERENCE($,'Zz_60_45_70','Regrade ground level',#12420,$,$); +#12424=IFCCLASSIFICATIONREFERENCE($,'Zz_60_50','Markers',#12413,$,$); +#12425=IFCCLASSIFICATIONREFERENCE($,'Zz_60_50_10','Break marks',#12424,$,$); +#12426=IFCCLASSIFICATIONREFERENCE($,'Zz_60_50_20','Callout marks',#12424,$,$); +#12427=IFCCLASSIFICATIONREFERENCE($,'Zz_60_50_30','Elevation marks',#12424,$,$); +#12428=IFCCLASSIFICATIONREFERENCE($,'Zz_60_50_60','Plan',#12424,$,$); +#12429=IFCCLASSIFICATIONREFERENCE($,'Zz_60_50_80','Section marks',#12424,$,$); +#12430=IFCCLASSIFICATIONREFERENCE($,'Zz_60_50_85','Span direction markers',#12424,$,$); +#12431=IFCCLASSIFICATIONREFERENCE($,'Zz_60_50_90','Void and opening markers',#12424,$,$); +#12432=IFCCLASSIFICATIONREFERENCE($,'Zz_60_55','Match lines',#12413,$,$); +#12433=IFCCLASSIFICATIONREFERENCE($,'Zz_70','Views',#12338,$,$); +#12434=IFCCLASSIFICATIONREFERENCE($,'Zz_70_05','3D views',#12433,$,$); +#12435=IFCCLASSIFICATIONREFERENCE($,'Zz_70_20','Details',#12433,$,$); +#12436=IFCCLASSIFICATIONREFERENCE($,'Zz_70_30','Elevations',#12433,$,$); +#12437=IFCCLASSIFICATIONREFERENCE($,'Zz_70_60','Plans',#12433,$,$); +#12438=IFCCLASSIFICATIONREFERENCE($,'Zz_70_80','Sections',#12433,$,$); +#12439=IFCCLASSIFICATIONREFERENCE($,'Zz_70_90','Visualisations',#12433,$,$); +#12440=IFCCLASSIFICATIONREFERENCE($,'Zz_80','Presentation',#12338,$,$); +#12441=IFCCLASSIFICATIONREFERENCE($,'Zz_80_30','Entourage',#12440,$,$); +#12442=IFCCLASSIFICATIONREFERENCE($,'Zz_80_45','Lines',#12440,$,$); +#12443=IFCCLASSIFICATIONREFERENCE($,'Zz_80_45_10','Fine',#12442,$,$); +#12444=IFCCLASSIFICATIONREFERENCE($,'Zz_80_45_20','Thin',#12442,$,$); +#12445=IFCCLASSIFICATIONREFERENCE($,'Zz_80_45_30','Light',#12442,$,$); +#12446=IFCCLASSIFICATIONREFERENCE($,'Zz_80_45_40','Medium',#12442,$,$); +#12447=IFCCLASSIFICATIONREFERENCE($,'Zz_80_45_50','Heavy',#12442,$,$); +#12448=IFCCLASSIFICATIONREFERENCE($,'Zz_80_45_60','Wide',#12442,$,$); +#12449=IFCCLASSIFICATIONREFERENCE($,'Zz_80_45_70','Extra-wide',#12442,$,$); +#12450=IFCCLASSIFICATIONREFERENCE($,'Zz_80_45_80','XX wide',#12442,$,$); +#12451=IFCCLASSIFICATIONREFERENCE($,'Zz_80_45_90','XXX wide',#12442,$,$); +#12452=IFCCLASSIFICATIONREFERENCE($,'Zz_80_60','People',#12440,$,$); +#12453=IFCCLASSIFICATIONREFERENCE($,'Zz_80_85','Trees and planting',#12440,$,$); +#12454=IFCCLASSIFICATIONREFERENCE($,'Zz_80_90','Vehicles',#12440,$,$); +#12455=IFCCLASSIFICATIONREFERENCE($,'Zz_85','Generic 3D',#12338,$,$); +#12456=IFCCLASSIFICATIONREFERENCE($,'Zz_85_05','3D solids',#12455,$,$); +#12457=IFCCLASSIFICATIONREFERENCE($,'Zz_85_05_60','Paths',#12456,$,$); +#12458=IFCCLASSIFICATIONREFERENCE($,'Zz_85_05_80','Solids',#12456,$,$); +#12459=IFCCLASSIFICATIONREFERENCE($,'Zz_85_05_85','Solid voids',#12456,$,$); +#12460=IFCCLASSIFICATIONREFERENCE($,'Zz_85_20','Concept',#12455,$,$); +#12461=IFCCLASSIFICATIONREFERENCE($,'Zz_85_20_20','Concept massing',#12460,$,$); +#12462=IFCCLASSIFICATIONREFERENCE($,'Zz_85_20_50','Mass group',#12460,$,$); +#12463=IFCCLASSIFICATIONREFERENCE($,'Zz_85_20_55','Mass slice',#12460,$,$); +#12464=IFCCLASSIFICATIONREFERENCE($,'Zz_90','Readme and plotting lines',#12338,$,$); +#12465=IFCCLASSIFICATIONREFERENCE($,'Zz_90_20','Construction lines',#12464,$,$); +#12466=IFCCLASSIFICATIONREFERENCE($,'Zz_90_30','External reference information',#12464,$,$); +#12467=IFCCLASSIFICATIONREFERENCE($,'Zz_90_70','Readme',#12464,$,$); ENDSEC; END-ISO-10303-21; diff --git a/src/ifcblenderexport/getIfcClassification.py b/src/ifcblenderexport/getIfcClassification.py deleted file mode 100644 index 5d8d8410c7..0000000000 --- a/src/ifcblenderexport/getIfcClassification.py +++ /dev/null @@ -1,63 +0,0 @@ -"""This script converts Graphisoft XML into an IFC file""" - -import xml.etree.ElementTree as ET -import ifcopenshell - -class IFC4Extractor: - def __init__(self, xml_file): - self.xml_file = xml_file - self.tree = ET.parse(self.xml_file) - self.root = self.tree.getroot() - self.ns = {'xs': 'http://www.w3.org/2001/XMLSchema'} - self.file = ifcopenshell.file() - self.source_map = { - 'Uniclass 2015': 'RIBA Enterprises Ltd', - 'OmniClass': 'OmniClass' - } - self.reference_tokens_map = { - 'Uniclass 2015': ['_'], - 'OmniClass': ['-', ' '] - } - - def extract(self): - for system in self.tree.findall('Classification/System'): - parent = self.file.create_entity('IfcClassification', **{ - 'Source': self.source_map[system.find('Name').text], - 'Edition': system.find('EditionVersion').text, - 'EditionDate': self.get_edition_date(system), - 'Name': system.find('Name').text, - 'Description': system.find('Description').text, - 'Location': system.find('Source').text, - 'ReferenceTokens': self.reference_tokens_map[system.find('Name').text] - }) - children = system.findall('Items/Item') - self.get_children(children, parent) - - def get_children(self, children, parent): - for child in children: - reference = self.file.create_entity('IfcClassificationReference', **{ - 'Identification': child.find('ID').text, - 'Name': child.find('Name').text, - 'ReferencedSource': parent, - 'Description': child.find('Description').text - }) - children = child.find('Children') - if children: - self.get_children(children, reference) - - def get_edition_date(self, system): - d = system.find('EditionDate') - return '{}-{:02}-{:02}'.format( - d.find('Year').text, int(d.find('Month').text), int(d.find('Day').text)) - - def export(self, filename): - self.file.write(filename) - -filenames = [ - 'Uniclass2015_Jan2020', - 'Omniclass_OCCS' -] -for filename in filenames: - extractor = IFC4Extractor(f'{filename}.xml') - extractor.extract() - extractor.export(f'{filename}.ifc')