Fix #9278. calculate_unit_scale raises the SI prefix to the length exponent for prefixed SQUARE_METRE/CUBIC_METRE units.

An SI prefix attaches to the base unit symbol and the prefixed symbol is
raised to the power as a whole: DECI CUBIC_METRE is dm3 = a litre = 1e-3 m3,
not 0.1 m3. The scale factor previously applied the prefix multiplier
linearly for all IfcSIUnits, inflating volumes x100 and areas x10 for such
declarations (produced e.g. by MagiCAD for Revit MEP exports).

Following the reviewer note in #9278, the exponent is taken from the
derived attribute IfcSIUnit.Dimensions rather than from substring matching
on the unit name: the multiplier is raised to LengthExponent only when the
unit's dimensions are a pure power of length, so prefixed derived units
(KILO PASCAL, MEGA NEWTON) and non-length units (KILO GRAM) correctly keep
the linear multiplier. This matches the exponent handling already present
in convert() and named_dimensions in the same module.

Adds regression tests for prefixed AREAUNIT/VOLUMEUNIT and for the
linear-prefix behaviour of PRESSUREUNIT/MASSUNIT.
This commit is contained in:
Robert Sigmundsson
2026-08-08 18:30:28 +02:00
committed by Thomas Krijnen
parent 7ed8584edc
commit f05dd4aea5
2 changed files with 48 additions and 1 deletions
@@ -720,7 +720,29 @@ def calculate_unit_scale(ifc_file: ifcopenshell.file, unit_type: str = "LENGTHUN
unit_scale *= conversion_factor.ValueComponent.wrappedValue
unit = conversion_factor.UnitComponent
if unit.is_a("IfcSIUnit"):
unit_scale *= get_prefix_multiplier(unit.Prefix)
prefix_multiplier = get_prefix_multiplier(unit.Prefix)
# An SI prefix attaches to the base unit symbol, and the prefixed
# symbol is raised to the power as a whole: dm3 = (dm)3 = 1e-3 m3,
# not 0.1 m3. For units whose dimensions are a pure power of length
# (METRE, SQUARE_METRE, CUBIC_METRE) the prefix multiplier must
# therefore be raised to the length exponent. Units with mixed or
# non-length dimensions (PASCAL, NEWTON, GRAM, ...) keep the linear
# multiplier, as there the prefix scales the derived unit itself.
# https://github.com/IfcOpenShell/IfcOpenShell/issues/9278
dimensions = unit.Dimensions
length_exponent = dimensions.LengthExponent
if length_exponent > 0 and not any(
(
dimensions.MassExponent,
dimensions.TimeExponent,
dimensions.ElectricCurrentExponent,
dimensions.ThermodynamicTemperatureExponent,
dimensions.AmountOfSubstanceExponent,
dimensions.LuminousIntensityExponent,
)
):
prefix_multiplier **= length_exponent
unit_scale *= prefix_multiplier
return unit_scale
@@ -200,6 +200,31 @@ class TestCalculateUnitScale(test.bootstrap.IFC4):
ifcopenshell.api.unit.assign_unit(self.file, units=[angle])
assert subject.calculate_unit_scale(self.file, "PLANEANGLEUNIT") == pi / 180 * 0.001
def test_prefix_is_raised_to_the_length_exponent_for_area_and_volume(self):
# A prefixed square/cubic metre is (prefix-metre) squared/cubed:
# DECI SQUARE_METRE = dm2 = 1e-2 m2, DECI CUBIC_METRE = dm3 (litre) = 1e-3 m3.
# https://github.com/IfcOpenShell/IfcOpenShell/issues/9278
ifcopenshell.api.root.create_entity(self.file, ifc_class="IfcProject")
area = ifcopenshell.api.unit.add_si_unit(self.file, unit_type="AREAUNIT")
area.Prefix = "DECI"
volume = ifcopenshell.api.unit.add_si_unit(self.file, unit_type="VOLUMEUNIT")
volume.Prefix = "DECI"
ifcopenshell.api.unit.assign_unit(self.file, units=[area, volume])
assert subject.calculate_unit_scale(self.file, "AREAUNIT") == pytest.approx(0.1**2)
assert subject.calculate_unit_scale(self.file, "VOLUMEUNIT") == pytest.approx(0.1**3)
def test_prefix_stays_linear_for_units_that_are_not_a_pure_power_of_length(self):
# For derived and non-length SI units the prefix scales the unit itself:
# KILO PASCAL = 1e3 Pa, KILO GRAM = 1e3 g.
ifcopenshell.api.root.create_entity(self.file, ifc_class="IfcProject")
pressure = ifcopenshell.api.unit.add_si_unit(self.file, unit_type="PRESSUREUNIT")
pressure.Prefix = "KILO"
mass = ifcopenshell.api.unit.add_si_unit(self.file, unit_type="MASSUNIT")
mass.Prefix = "KILO"
ifcopenshell.api.unit.assign_unit(self.file, units=[pressure, mass])
assert subject.calculate_unit_scale(self.file, "PRESSUREUNIT") == pytest.approx(1000)
assert subject.calculate_unit_scale(self.file, "MASSUNIT") == pytest.approx(1000)
class TestFormatLength(test.bootstrap.IFC4):
def test_run(self):