// // (C) Copyright 2003-2019 by Autodesk, Inc. // // Permission to use, copy, modify, and distribute this software in // object code form for any purpose and without fee is hereby granted, // provided that the above copyright notice appears in all copies and // that both that copyright notice and the limited warranty and // restricted rights notice below appear in all supporting // documentation. // // AUTODESK PROVIDES THIS PROGRAM "AS IS" AND WITH ALL FAULTS. // AUTODESK SPECIFICALLY DISCLAIMS ANY IMPLIED WARRANTY OF // MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE. AUTODESK, INC. // DOES NOT WARRANT THAT THE OPERATION OF THE PROGRAM WILL BE // UNINTERRUPTED OR ERROR FREE. // // Use, duplication, or disclosure by the U.S. Government is subject to // restrictions set forth in FAR 52.227-19 (Commercial Computer // Software - Restricted Rights) and DFAR 252.227-7013(c)(1)(ii) // (Rights in Technical Data and Computer Software), as applicable. // using System; using System.Collections.Generic; using System.Linq; using System.Text; using Autodesk.Revit; using Autodesk.Revit.DB; using Autodesk.Revit.UI; using Autodesk.Revit.DB.Fabrication; using System.Windows.Forms; namespace Revit.SDK.Samples.FabricationPartLayout.CS { /// /// Implements the Revit add-in interface IExternalCommand /// [Autodesk.Revit.Attributes.Transaction(Autodesk.Revit.Attributes.TransactionMode.Manual)] [Autodesk.Revit.Attributes.Regeneration(Autodesk.Revit.Attributes.RegenerationOption.Manual)] public class PartRenumber : IExternalCommand { #region region Member Variables private int m_ductNum = 1; private int m_ductCouplingNum = 1; private int m_pipeNum = 1; private int m_pipeCouplingNum = 1; private int m_hangerNum = 1; private int m_otherNum = 1; #endregion /// /// Implement this method as an external command for Revit. /// /// An object that is passed to the external application /// which contains data related to the command, /// such as the application object and active view. /// A message that can be set by the external application /// which will be displayed if a failure or cancellation is returned by /// the external command. /// A set of elements to which the external application /// can add elements that are to be highlighted in case of failure or cancellation. /// Return the status of the external command. /// A result of Succeeded means that the API external method functioned as expected. /// Cancelled can be used to signify that the user cancelled the external operation /// at some point. Failure should be returned if the application is unable to proceed with /// the operation. public virtual Result Execute(ExternalCommandData commandData , ref string message, ElementSet elements) { try { // check user selection var uidoc = commandData.Application.ActiveUIDocument; var doc = uidoc.Document; var collection = uidoc.Selection.GetElementIds(); using (var trans = new Transaction(doc, "Part Renumber")) { trans.Start(); var fabParts = new List(); foreach (var elementId in collection) { var part = doc.GetElement(elementId) as FabricationPart; if (part != null) { part.ItemNumber = string.Empty; // wipe the item number fabParts.Add(part); } } if (fabParts.Count == 0) { message = "Select at least one fabrication part"; return Result.Failed; } // ignore certain fields var ignoreFields = new List(); ignoreFields.Add(FabricationPartCompareType.Notes); ignoreFields.Add(FabricationPartCompareType.OrderNo); ignoreFields.Add(FabricationPartCompareType.Service); for (int i = 0; i < fabParts.Count; i++) { var part1 = fabParts[i]; if (string.IsNullOrWhiteSpace(part1.ItemNumber)) { // part has not already been checked if (IsADuct(part1)) { if (IsACoupling(part1)) part1.ItemNumber = "DUCT COUPLING: " + m_ductCouplingNum++; else part1.ItemNumber = "DUCT: " + m_ductNum++; } else if (IsAPipe(part1)) { if (IsACoupling(part1)) part1.ItemNumber = "PIPE COUPLING: " + m_pipeCouplingNum++; else part1.ItemNumber = "PIPE: " + m_pipeNum++; } else if (part1.IsAHanger()) part1.ItemNumber = "HANGER: " + m_hangerNum++; else part1.ItemNumber = "MISC: " + m_otherNum++; } for (int j = i + 1; j < fabParts.Count; j++) { var part2 = fabParts[j]; if (string.IsNullOrWhiteSpace(part2.ItemNumber)) { // part2 has not been checked if (part1.IsSameAs(part2, ignoreFields)) { // items are the same, so give them the same item number part2.ItemNumber = part1.ItemNumber; } } } } trans.Commit(); } TaskDialog td = new TaskDialog("Fabrication Part Renumber") { MainIcon = TaskDialogIcon.TaskDialogIconInformation, TitleAutoPrefix = false, MainInstruction = "Renumber was successful", AllowCancellation = false, CommonButtons = TaskDialogCommonButtons.Ok }; td.Show(); return Result.Succeeded; } catch (Exception ex) { message = ex.Message; return Result.Failed; } } /// /// Checks if the given part is fabrication ductwork. /// /// The part to check. /// True if the part is fabrication ductwork. private bool IsADuct(FabricationPart fabPart) { return (fabPart != null && (fabPart.Category.Id.IntegerValue == (int)BuiltInCategory.OST_FabricationDuctwork)); } /// /// Checks if the part is fabrication pipework. /// /// The part to check. /// True if the part is fabrication pipework. private bool IsAPipe(FabricationPart fabPart) { return (fabPart != null && (fabPart.Category.Id.IntegerValue == (int)BuiltInCategory.OST_FabricationPipework)); } /// /// Checks if the part is a coupling. /// The CID's (the fabrication part item customer Id) that are recognized internally as couplings are: /// CID 522, 1112 - Round Ductwork /// CID 1522 - Oval Ductwork /// CID 4522 - Rectangular Ductwork /// CID 2522 - Pipe Work /// CID 3522 - Electrical /// /// The part to check. /// True if the part is a coupling. private bool IsACoupling(FabricationPart fabPart) { if (fabPart != null) { int CID = fabPart.ItemCustomId; if (CID == 522 || CID == 1522 || CID == 2522 || CID == 3522 || CID == 1112) { return true; } } return false; } } }