// // (C) Copyright 2003-2019 by Autodesk, Inc. // // Permission to use, copy, modify, and distribute this software in // object code form for any purpose and without fee is hereby granted, // provided that the above copyright notice appears in all copies and // that both that copyright notice and the limited warranty and // restricted rights notice below appear in all supporting // documentation. // // AUTODESK PROVIDES THIS PROGRAM "AS IS" AND WITH ALL FAULTS. // AUTODESK SPECIFICALLY DISCLAIMS ANY IMPLIED WARRANTY OF // MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE. AUTODESK, INC. // DOES NOT WARRANT THAT THE OPERATION OF THE PROGRAM WILL BE // UNINTERRUPTED OR ERROR FREE. // // Use, duplication, or disclosure by the U.S. Government is subject to // restrictions set forth in FAR 52.227-19 (Commercial Computer // Software - Restricted Rights) and DFAR 252.227-7013(c)(1)(ii) // (Rights in Technical Data and Computer Software), as applicable. // using System; using System.Collections.Generic; using System.Windows.Forms; using Autodesk.Revit; using Autodesk.Revit.DB; using Autodesk.Revit.UI; namespace Revit.SDK.Samples.ValidateParameters.CS { /// /// A class inherits IExternalCommand interface. /// this class controls the class which subscribes handle events and the events' information UI. /// like a bridge between them. /// [Autodesk.Revit.Attributes.Transaction(Autodesk.Revit.Attributes.TransactionMode.Manual)] [Autodesk.Revit.Attributes.Regeneration(Autodesk.Revit.Attributes.RegenerationOption.Manual)] [Autodesk.Revit.Attributes.Journaling(Autodesk.Revit.Attributes.JournalingMode.NoCommandData)] public class Command:IExternalCommand { #region Class Memeber Variables /// /// store the family manager /// FamilyManager m_familyManager; #endregion #region Class Interface Implementation /// /// Implement this method as an external command for Revit. /// /// An object that is passed to the external application /// which contains data related to the command, /// such as the application object and active view. /// A message that can be set by the external application /// which will be displayed if a failure or cancellation is returned by /// the external command. /// A set of elements to which the external application /// can add elements that are to be highlighted in case of failure or cancellation. /// Return the status of the external command. /// A result of Succeeded means that the API external method functioned as expected. /// Cancelled can be used to signify that the user cancelled the external operation /// at some point. Failure should be returned if the application is unable to proceed with /// the operation. public Autodesk.Revit.UI.Result Execute(ExternalCommandData commandData, ref string message, ElementSet elements) { Document document; document = commandData.Application.ActiveUIDocument.Document; // only a family document can retrieve family manager if (document.IsFamilyDocument) { m_familyManager = document.FamilyManager; List errorMessages = ValidateParameters(m_familyManager); using(MessageForm msgForm = new MessageForm(errorMessages.ToArray())) { msgForm.StartPosition = FormStartPosition.CenterParent; msgForm.ShowDialog(); return Autodesk.Revit.UI.Result.Succeeded; } } else { message = "please make sure you have opened a family document!"; return Autodesk.Revit.UI.Result.Failed; } } #endregion #region Class Implementation /// /// implementation of validate parameters, get all family types and parameters, /// use the function FamilyType.HasValue() to make sure if the parameter needs to /// validate. Then along to the storage type to validate the parameters. /// /// error information list public static List ValidateParameters(FamilyManager familyManager) { List errorInfo = new List(); // go though all parameters foreach (FamilyType type in familyManager.Types) { bool right = true; foreach (FamilyParameter para in familyManager.Parameters) { try { if (type.HasValue(para)) { switch (para.StorageType) { case StorageType.Double: if (!(type.AsDouble(para) is double)) right = false; break; case StorageType.ElementId: try { Autodesk.Revit.DB.ElementId elemId=type.AsElementId(para); } catch { right = false; } break; case StorageType.Integer: if (!(type.AsInteger(para) is int)) right = false; break; case StorageType.String: if (!(type.AsString(para) is string)) right = false; break; default: break; } } } // output the parameters which failed during validating. catch { errorInfo.Add("Family Type:" + type.Name + " Family Parameter:" + para.Definition.Name + " validating failed!"); } if (!right) { errorInfo.Add("Family Type:" + type.Name + " Family Parameter:" + para.Definition.Name + " validating failed!"); } } } return errorInfo; } #endregion } }