<?xml version="1.0" encoding="utf-8"?>
<MechanicalSystem>
<BasicInformation>
<Name>Mechanical Supply Air 1</Name>
<Id>382490</Id>
<UniqueId>23917bfa-2fdc-40f2-99d5-d76b395d58bc-0005d61a</UniqueId>
<SystemType>SupplyAir</SystemType>
<Category Id="-2008015" Name="Duct Systems" />
<IsWellConnected>true</IsWellConnected>
<IsDefaultSystem>false</IsDefaultSystem>
<HasBaseEquipment>true</HasBaseEquipment>
<TerminalElementsCount>2</TerminalElementsCount>
<Flow>16.666666666666668</Flow>
</BasicInformation>
<Path>
<MechanicalEquipment Name="Size 4 - 10 inch Inlet" Id="378728" Direction="Out" />
<MechanicalFitting Category="Duct Fittings" PartType="Transition" Name="Standard" Id="382496" Direction="In" />
<Duct Name="Radius Elbows / Tees" Id="382491" Direction="In" />
<MechanicalFitting Category="Duct Fittings" PartType="Elbow" Name="1.5 W" Id="382493" Direction="In" />
<Duct Name="Radius Elbows / Tees" Id="382492" Direction="In" />
<MechanicalFitting Category="Duct Fittings" PartType="Elbow" Name="1.5 W" Id="382507" Direction="In" />
<Duct Name="Radius Elbows / Tees" Id="382506" Direction="In" />
<MechanicalFitting Category="Duct Fittings" PartType="Elbow" Name="1.5 W" Id="382508" Direction="In" />
<Duct Name="Radius Elbows / Tees" Id="382500" Direction="In" />
<MechanicalFitting Category="Duct Fittings" PartType="Tee" Name="Standard" Id="382505" Direction="In" />
<Path>
<Duct Name="Radius Elbows / Tees" Id="382501" Direction="In" />
<MechanicalFitting Category="Duct Fittings" PartType="Elbow" Name="1.5 W" Id="382503" Direction="In" />
<Duct Name="Radius Elbows / Tees" Id="382498" Direction="In" />
<FamilyInstance Category="Air Terminals" Name="24 x 24 Face 12 x 12 Connection" Id="378707" Direction="In" />
</Path>
<Path>
<Duct Name="Radius Elbows / Tees" Id="382502" Direction="In" />
<MechanicalFitting Category="Duct Fittings" PartType="Elbow" Name="1.5 W" Id="382504" Direction="In" />
<Duct Name="Radius Elbows / Tees" Id="382499" Direction="In" />
<FamilyInstance Category="Air Terminals" Name="24 x 24 Face 12 x 12 Connection" Id="378716" Direction="In" />
</Path>
</Path>