Remove ShowPortFlowError operator and update flow direction handling for connected ports
This commit is contained in:
@@ -45,7 +45,6 @@ classes = (
|
||||
operator.RemoveZone,
|
||||
operator.SelectSystemProducts,
|
||||
operator.SetFlowDirection,
|
||||
operator.ShowPortFlowError,
|
||||
operator.ShowPorts,
|
||||
operator.UnassignSystem,
|
||||
operator.UnloadZones,
|
||||
|
||||
@@ -451,28 +451,23 @@ class CycleFlowDirection(bpy.types.Operator, tool.Ifc.Operator):
|
||||
|
||||
tool.Ifc.run("attribute.edit_attributes", product=port, attributes={"FlowDirection": next_direction})
|
||||
|
||||
connected_port = tool.System.get_connected_port(port)
|
||||
if connected_port:
|
||||
# Map flow direction to connected port's complementary direction
|
||||
connected_direction_map = {
|
||||
"SOURCE": "SINK",
|
||||
"SINK": "SOURCE",
|
||||
"SOURCEANDSINK": "SOURCEANDSINK",
|
||||
"NOTDEFINED": "NOTDEFINED"
|
||||
}
|
||||
connected_direction = connected_direction_map.get(next_direction, "NOTDEFINED")
|
||||
tool.Ifc.run("attribute.edit_attributes", product=connected_port, attributes={"FlowDirection": connected_direction})
|
||||
|
||||
PortData.is_loaded = False
|
||||
|
||||
return {"FINISHED"}
|
||||
|
||||
|
||||
class ShowPortFlowError(bpy.types.Operator):
|
||||
bl_idname = "bim.show_port_flow_error"
|
||||
bl_label = ""
|
||||
bl_options = {"REGISTER"}
|
||||
port_flow: bpy.props.StringProperty()
|
||||
connected_flow: bpy.props.StringProperty()
|
||||
|
||||
@classmethod
|
||||
def description(cls, context, operator):
|
||||
if operator.port_flow and operator.connected_flow:
|
||||
return f"Semantic error: Incompatible flow directions ({operator.port_flow} connected to {operator.connected_flow})"
|
||||
return "Semantic error: Incompatible flow directions"
|
||||
|
||||
def execute(self, context):
|
||||
return {"FINISHED"}
|
||||
|
||||
|
||||
class LoadZones(bpy.types.Operator):
|
||||
bl_idname = "bim.load_zones"
|
||||
bl_label = "Load Zones"
|
||||
|
||||
@@ -168,7 +168,7 @@ class BIM_PT_ports(Panel):
|
||||
row.label(text="Ports located on object and connected Port/Objects:")
|
||||
|
||||
row = self.layout.row(align=True)
|
||||
cols = [row.column(align=True) for i in range(10)]
|
||||
cols = [row.column(align=True) for i in range(9)]
|
||||
|
||||
for port_data in PortData.data["located_ports_data"]:
|
||||
flow_direction_icon = FLOW_DIRECTION_TO_ICON[port_data["FlowDirection"] or "NOTDEFINED"]
|
||||
@@ -210,19 +210,6 @@ class BIM_PT_ports(Panel):
|
||||
ifc_id = tool.Blender.get_ifc_definition_id(connected_obj)
|
||||
cols[7].operator("bim.select_entity", text="", icon="RESTRICT_SELECT_OFF").ifc_id = ifc_id
|
||||
cols[8].label(text=port_data["connected_obj_name"])
|
||||
|
||||
if connected_port:
|
||||
port_flow = port.FlowDirection or "NOTDEFINED"
|
||||
connected_flow = connected_port.FlowDirection or "NOTDEFINED"
|
||||
if (port_flow == "SOURCE" and connected_flow == "SOURCE") or \
|
||||
(port_flow == "SINK" and connected_flow == "SINK"):
|
||||
op = cols[9].operator("bim.show_port_flow_error", text="", icon="ERROR", emboss=False)
|
||||
op.port_flow = port_flow
|
||||
op.connected_flow = connected_flow
|
||||
else:
|
||||
cols[9].label(text="", icon="BLANK1")
|
||||
else:
|
||||
cols[9].label(text="", icon="BLANK1")
|
||||
else:
|
||||
cols[4].label(text="", icon="BLANK1")
|
||||
cols[5].label(text="", icon="BLANK1")
|
||||
@@ -230,7 +217,6 @@ class BIM_PT_ports(Panel):
|
||||
cols[6].prop(props, "related_port_object", text="")
|
||||
cols[7].label(text="", icon="BLANK1")
|
||||
cols[8].label(text="Port is disconnected")
|
||||
cols[9].label(text="", icon="BLANK1")
|
||||
|
||||
|
||||
class BIM_PT_port(Panel):
|
||||
@@ -277,7 +263,7 @@ class BIM_PT_port(Panel):
|
||||
props = tool.System.get_system_props()
|
||||
|
||||
row = layout.row(align=True)
|
||||
cols = [row.column(align=True) for i in range(10)]
|
||||
cols = [row.column(align=True) for i in range(9)]
|
||||
|
||||
flow_direction_icon = FLOW_DIRECTION_TO_ICON[element.FlowDirection or "NOTDEFINED"]
|
||||
connected_port = tool.System.get_connected_port(element)
|
||||
@@ -311,16 +297,6 @@ class BIM_PT_port(Panel):
|
||||
else:
|
||||
cols[7].label(text="", icon="BLANK1")
|
||||
cols[8].label(text="")
|
||||
|
||||
port_flow = element.FlowDirection or "NOTDEFINED"
|
||||
connected_flow = connected_port.FlowDirection or "NOTDEFINED"
|
||||
if (port_flow == "SOURCE" and connected_flow == "SOURCE") or \
|
||||
(port_flow == "SINK" and connected_flow == "SINK"):
|
||||
op = cols[9].operator("bim.show_port_flow_error", text="", icon="ERROR", emboss=False)
|
||||
op.port_flow = port_flow
|
||||
op.connected_flow = connected_flow
|
||||
else:
|
||||
cols[9].label(text="", icon="BLANK1")
|
||||
else:
|
||||
cols[4].label(text="", icon="BLANK1")
|
||||
cols[5].label(text="", icon="BLANK1")
|
||||
@@ -328,7 +304,6 @@ class BIM_PT_port(Panel):
|
||||
cols[6].prop(props, "related_port_object", text="")
|
||||
cols[7].label(text="", icon="BLANK1")
|
||||
cols[8].label(text="Port is disconnected")
|
||||
cols[9].label(text="", icon="BLANK1")
|
||||
|
||||
|
||||
class BIM_PT_flow_controls(Panel):
|
||||
|
||||
Reference in New Issue
Block a user